TSW200E1. Description

Size: px
Start display at page:

Download "TSW200E1. Description"

Transcription

1 TSW200E1 Description The TSW200E1 is a field-portable Telecom Datacom Analyzer for installing, maintaining and testing asynchronous (50 bps up to bps) and synchronous (1200 bps up to 10 Mbps) digital data communication lines and framed 2048 Kbps PCM (E1) or 64 Kbps X.50 circuits. Optional modules for networks and telephony such as Frame Relay, X.25, X.50, PPP, chdlc, DTMF, MFC-R2, VT-100, Pulse Mask and ISDN-PRI are also available. It's most simple test is the Bit Error Rate (BERT). The local unit sends a known bit pattern to the remote unit that checks the incoming data searching for incorrectly received bits. So the Bit Error Rate is measured to see if the link meets the required quality. Error histograms are recorded over a long time run test to check when the errors are happening. General Characteristics Features Interfaces V.24/RS232, V.35/V.11, V.36/V.11, X.21/V.11, RS530, G Kbps (codirectional) and G.703-2Mbps (Rec.G.704 ITU-T). Standard Modules: This is the minimum configuration. BERT/BLERT: Bit Error Rate (BER), Block Error Rate (BLER), slip errors are measured and Recommendations G.821 and G.822 analysis are performed. Pattern Loss, Sync Loss, All zeroes, All ones, No Clock and many other alarms are recorded. E1/G.704: Bit Error Rate (BER) in E1 links (2Mbps) that use framed G.704 (PCM30, PCM30C, PCM31 e PCM31C). Recs G.821, G.826 and M2100 analysis are performed. Optional Modules: They are set up under the customers requirement when ordering the equipment. Frame Relay Module: testing of Frame Relay communication protocol networks. X.25 Mode: testing of SDLC, HDLC, X.25, ASYNC, SYNC and DDCMP communication protocol networks.

2 PPP Module: testing connectivity and response time in synchronous PPP links. X.50 Module: testing of framed links running Recommendation X.50 MFC-R2 Module: analysis and simulation of the MFC/R2 signaling in E1 links. DTMF Module: analysis and simulation of the DTMF signaling in E1 links. ISDN Module: analysis and simulation of the ISDN-PRI signaling in E1 links. VT-100 Module: emulation of VT-100 terminal to program modems, routers and other equipments. Ethernet Module: testing connectivity and response time through a local Ethernet network. Pulse Mask Module: checking the pulse shape of the E1 signal to see if it meets the requirements of ITU-T Rec. G.703. The pulse's shape is displayed. MODULES 1. BERT/BLERT MODULE a) Synchronous and Asynchronous Modes Synchronous operation rate: from 1200 bps up to 10 Mbps. Asynchronous operation rate: from 50 bps up to bps. Full-Duplex. Errored bits / blocks rate. Degraded minutes, severely errored seconds, errored seconds, error free seconds, available and unavailable seconds according to the ITU-T Recommendation G.821. Real time clock SLIPS and ITU-T Recommendation G.822. Bits/char and stop bits parity bit selection (asynchronous mode). Generated patterns in Synchronous Mode: 7 (2E3-1), 15 (2E4-1), 31 (2E5-1),63 (2E6-1), 127(2E7-1), 127 LA, 127 LD, 511 (2E9-1), 1023 (2E10-1), 2047 (2E11-1), 2E15-1, 2E17-1, 2E18-1, 2E20-1 O153, 2E20-1 O151, QRSS, 2E21-1, 2E22-1, 2E23-1, 2E25-1, 2E28-1, 2E29-1, 2E31-1, 2E32-1, Mark ('1111'), Space ('0000'), ALT M/S, Doublé Alt ('1100'), 3 in 24, 1 in 16, 1 in 8, 1 in 4, D4 LA, D4 LD, USER, 7:1, in the normal and inverted polarities. Internal and external clock options and also recovered clock for the G Kbps interface and regenerated (FROM RX) for the G.703-2Mbps interface. Line code in the G.703-2Mbps interface: HDB3 or AMI. G.703-2Mbps interface impedance: 75 Ohms, 120 Ohms or High Impedance (HIGHZ).

3 User pre-set time and continuous tests. Error insertion: manual or automatic. Histograms resolution: minutes or hours. 2. E1/G.704 MODULE a) TX/RX Framed: The TSW200E1 transmits and receives any framed testing pattern and counts errored bits/blocks rate, FAS error, code error, signal loss, AIS, FAS loss, CAS loss, PAT loss, and many other alarms. PCM30, PCM30C, PCM31 or PCM31C framed signal generation. Generated patterns: 7 (2E3-1), 15 (2E4-1), 31 (2E5-1),63 (2E6-1), 127(2E7-1), 127 LA, 127 LD, 511 (2E9-1), 1023 (2E10-1), 2047 (2E11-1), 2E15-1, 2E17-1, 2E18-1, 2E20-1 O153, 2E20-1 O151, QRSS, 2E21-1, 2E22-1, 2E23-1, 2E25-1, 2E28-1, 2E29-1, 2E31-1, 2E32-1, Mark ('1111'), Space ('0000'), ALT M/S, Double Alt ('1100'), 3 in 24, 1 in 16, 1 in 8, 1 in 4, D4 LA, D4 LD, USER, 7:1, IDLE, AUTO. Selection of timeslot(s) to be tested. Idle code selection to be transmitted in the non-selected channels. Internal, external and reception (FROM RX) regenerated clock. "DROP & INSERT" option that allows the TSW200E1 works as a fractional E1. Interfaces: RS232, V.35, V.36 and X.21 (only if one of the options: DROP, INSERT or DROP & INSERT is chosen). G.703-2Mbps interface line code: HDB3 or AMI. G.703-2Mbps Interface impedance: 75 Ohms, 120 Ohms or High Impedance (HIGHZ). Sa and ABCD bits set up in the NFAS words and timeslot 16. Degraded minutes, severely errored seconds, errored seconds, error free seconds, available and unavailable seconds counting according to the ITU-T Recommendation G.821. Blocks, errored blocks, background blocks, errored seconds, severely errored seconds, available and unavailable seconds counting according to ITU-T Recommendation G.826. Errored seconds, severely errored seconds, available and unavailable seconds counting according to the ITU-T M.2100 error analysis. User pre-set time and continuous tests. Error insertion: manual or automatic. Histograms resolution: minutes or hours. b) Through Framed: The TSW200E1 is inserted in the circuit under test and the framed signal received by the TSW200E1 is forwarded to its transmitter. It is then possible to drop / insert one or more timeslots via RS232, V.35, V.36, RS530 or X.21 interfaces.

4 Replacing, by any testing pattern, the framed data in one or more timeslots (channel). Monitoring a chosen timeslot, even listening a voice transmission with a built-in speaker. Checking for alarms in the link without interfering in the data path. c) Mux: The TSW200E1 performs E1 multiplexer tests. Testing pattern sent in one or more channels of the multiplexer via the RS232, V.35, V.36, RS530 or X.21 interfaces. Assessing the 2 Mbps framed data beam generated by the multiplexer. d) Demux: The TSW200E1 performs E1 demultiplexer tests. Transmitting the 2 Mbps framed data to a E1 demultiplexer. Receiving the demultiplexed data in one or more channels in one of the interfaces: RS232, V.35, V.36, RS530 or X.21. e) Monitor: The TSW200E1 performs monitoring E1 links: Monitoring the Si, Sa, A and E bits of the NFAS word in timeslot 0. Monitoring the FAS, NFAS, MFAS, NMFAS and CRC MFAS words. Monitoring the eight-bit code word in any timeslot. Monitoring the CAS (Channel Associated Signaling) status for all the 30 telephone channels. f) Frequency/Level Mode: The TSW200E1 allows for a level and frequency settable digitalized sinusoid to be inserted in any E1 timeslot. Simultaneously, allows for assessing the level and frequency of a channel output sinusoid. g) Round-trip Delay: The TSW200E1 allows for measuring the delay of the path under test. To do so, a remote loop is performed and a mark is inserted during transmission. The delay is obtained when this mark is received back. All the testing patterns can be used in the transmission. 3. FRAME RELAY MODULE The TSW200E1 performs the management linkage between the DTE (Data Terminal Equipment) and the network and checks if the frames are being correctly transmitted and received in a Frame Relay protocol structure. The Frame Relay mode performs three kinds of tests:

5 a) TURN UP Idle flag detection (7E hexadecimal) Active linkage checking (Frame Relay Heartbeat) Status Enquiry (question) and Status (answer) messages assessment Linkage integrity checking (LIV) Identification of set up DLCIs and of its status FCS Frame Relay error checking b) PING End to end connectivity checking in TCP/IP protocol networks c) FOX End to end connectivity checking in non-tcp/ip protocol networks. Network "stress" checking through a frame continuous traffic at a user defined rate (CIR). 4. X.25/XDLC MODULE The TSW200E1 performs tests in the SDLC, HDLC, X.25, ASYNC, SYNC and DDCMP protocols and checks the linkage integrity upon observing if the frames are correctly being transmitted and received. ASYNC and SYNC tests monitor the data that go through a DTE DCE linkage, by means of sending and receiving data previously stored in buffers. Interfaces: V.24/RS232, V.35/V.11, V.36/V.11 and X.21/V.11. Operation speed: from 1200 bps to 256 Kbps synchronous or from 50 bps to bps asynchronous. Code operation ASCII, HEX and EBCDIC. 5. PPP MODULE The TSW200E1 performs connectivity tests in PPP protocol networks, and can, for example, replace a router and ping a remote point. Interfaces: V.24/RS232, V.35/V.11, V.36/V.11 and X.21/V.11. Operation speed: from 1200 bps to 256 Kbps, synchronous communication mode only. First, the TSW200E1 sends LCP protocol packages, establishes and sets the link up. Next, NCP packages are sent so as to define what network protocol to be used. In this case, the protocol used will be the IPCP.

6 Allows checking the end-to-end connectivity inside the network and the response time for remote points through sent PING packages. 6. X.50 MODULE The X.50 structure used at 64 Kbps allows for the carriage of many data channels with lower rates inside the 64Kbps synchronous band width. Generation and assessment of framed signal in divisions 2 and 3. Generated sequences: 63, 511, 2047, 2E15-1, 2E20-1, Mark, Space, ALT-M/S, USER, in the regular and inverted modes. Independent selection of transmission and reception octets. Errors assessment and alarms. Internal, external and reception regenerated clock. Idle code and BERT/IDLE status bits set up. Test length: continuous or user defined. 7. MFC-R2 MODULE The TSW200E1 CAS MFC-R2 module is able to record the entire process of establishing a call using the ABCD bits of E1 beam (CAS bits) and the multi-frequency signaling tones that occur in the correspondent time-slots. The TSW200E1 can act as a simulator or analyzer in a communication that uses the MFCR2 signaling. As an analyzer, the equipment receives both forward and backward signals, identifying the line (R2 digital) signaling and the multi-frequency signaling (MFC) in all the channels. This option allows observation of the communication without interfering with it. As a simulator, it takes over one of the extremes of the communication, answering the received calls or starting one. 8. VT-100 MODULE With this options installed the TSW200E1 can act as a VT-100 console terminal to program routers, modems and any equipment that runs VT-100 protocol. The great advantage is to avoid the need of a microcomputer in the field to have this task done. 9. ETHERNET MODULE This module lets the TSW200E1 verify the connectivity of a local network with the Internet. It can test the Ethernet interface of modems, routers, etc... A Ping test can be done using IP addresses or URLs. A mini-browser is also available to access any Internet website. 10. chdlc MODULE

7 The TSW200E1 performs connectivity tests in chdlc protocol networks, and can, for example, replace a Cisco router to ping a remote point. Interfaces: V.24/RS232, V.35/V.11, V.36/V.11 and X.21/V.11. Operation speed: from 1200 bps to 256 Kbps, in synchronous communication mode only. The TSW200E1 sends SLARP to establish and set the link up and then it checks the end-to-end connectivity and response times sending PING packages. 11. PULSE MASK MODULE This module displays a single pulse of the G703 received signal at the screen and lets the user check if it fits inside the required mask that it is drawn together. It also shows several measurements, such as overshoot, undershoot, rising edge, falling edge, pulse level and pulse width. The TSW200E1 also allows for: Memory storing the results of the tests performed, for further checking. Storing the setup of the most used testing parameters. Printing out the results of the stored tests through a serial interface, in serial, parallel printers (using the serial-parallel conversion cable) and in PCs (through the hyperterminal). Memory, display, LEDs and keyboard self-test.

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options: FEATURES E1 or Fractional E1 access unit Supports one data port with selectable sync data rates: n x 56, n x 64 kbps Optional sub-e1 drop & insert port for PABX connectivity Single slot supports MEGAPLEX

More information

Acterna E1 and Data Testers

Acterna E1 and Data Testers Acterna E1 and Data Testers (EST-120, EST-125, EDT-130, EDT-135) Scalable testing for digital networks The range of E1 and Data Testers provide a scalable, future-proof solution for the testing needs of

More information

AMX-1344 Access DCS-MUX

AMX-1344 Access DCS-MUX AMX-1344 Access DCS-MUX Description Features : Support DACS (Digital Access Cross-connect System) with full cross-connect Support full DS0 cross-connect, backplane capacity up to 128 Mbps Single controller,

More information

Universal Multiservice Digital Access Cross Connection

Universal Multiservice Digital Access Cross Connection Universal Multiservice Digital Access Cross Connection Telecom Equipment Series Overview The TM3100 is a compact access DCS-MUX that can combine various digital access interfaces into T1 or E1 lines for

More information

PPP. Point-to-Point Protocol

PPP. Point-to-Point Protocol PPP Point-to-Point Protocol 1 Introduction One of the most common types of WAN connection is the point-to-point connection. Point-to-point connections are used to connect LANs to service provider WANs,

More information

HCT-BERT/C(E1) E1/Datacom BER Tester

HCT-BERT/C(E1) E1/Datacom BER Tester E1/Datacom BER Tester LEGAL The information in this publication has been carefully checked and is believed to be entirely accurate at the time of publication. CTC Union Technologies assumes no responsibility,

More information

Chapter 2. Hardware Description. 2.1 Chassis. Note: For product specifications, see Appendix A, Specifications.

Chapter 2. Hardware Description. 2.1 Chassis. Note: For product specifications, see Appendix A, Specifications. Chapter 2 Hardware Description This chapter provides information on the hardware for the BANDIT product family. Note: For product specifications, see Appendix A, Specifications. 2.1 Chassis The chassis

More information

DCB-AM 3440 Access DCS-MUX

DCB-AM 3440 Access DCS-MUX Access DCS-Mux DCB-AM 3440 Access DCS-MUX Description Features : Support DACS (Digital Access Cross-connect System) with full cross-connect Support full DS0 cross-connect, backplane capacity up to 128

More information

E20c Final qxd 10/26/04 8:09 AM Page 1. SunSet E20c. Powerful 2 Mbit/s, Datacom, Cellular, Signalling, and Service Testing

E20c Final qxd 10/26/04 8:09 AM Page 1. SunSet E20c. Powerful 2 Mbit/s, Datacom, Cellular, Signalling, and Service Testing E20c Final 10-04.qxd 10/26/04 8:09 AM Page 1 a a step step ahead ahead SunSet E20c Powerful 2 Mbit/s, Datacom, Cellular, Signalling, and Service Testing E20c Final 10-04.qxd 10/26/04 8:09 AM Page 2 Each

More information

DTA-BERT/T. Operation Manual. Copyright 2009, Shineway Technologies, Inc. All rights reserved. Shineway Technologies, Inc.

DTA-BERT/T. Operation Manual. Copyright 2009, Shineway Technologies, Inc. All rights reserved. Shineway Technologies, Inc. DTA-BERT/T Operation Manual Copyright 2009, Shineway Technologies, Inc. All rights reserved Shineway Technologies, Inc. Contents Chapter 1 DTA-BERT/T Overview... 3 1.1 Introduction... 3 1.2 Function...

More information

Software version Mar 16, 2015

Software version Mar 16, 2015 TX130+ Firmware/Software Updates Software version 3.5.5-0 Jul 22, 2015 1. Improved G.703 64k Codirectional interface testing functionality 2. Improved NIU FAC2 loop command 3. New Sa bits E1 Synchronization

More information

Atrie WireSpan 620. User's Manual

Atrie WireSpan 620. User's Manual Atrie WireSpan 620 User's Manual WireSpan 620 Fractional E1/Ethernet Access Unit Installation and Operation Manual (Version 1.00) CONTENTS CHAPTER 1 Introduction.. 1-1 CHAPTER 2 Installation and Setup..

More information

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO F8008 Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet + optional V.35/QFXS/QFXO Description F8008 is a fiber optical multiplexer of new generation different from the traditional PDH, multiplexing 1 full

More information

T1 E1 Analyzer Special Applications

T1 E1 Analyzer Special Applications T1 E1 Analyzer Special Applications 818 West Diamond Avenue - Third Floor, Gaithersburg, MD 20878 Phone: (301) 670-4784 Fax: (301) 670-9187 Email: gl-info@gl.com Website: http://www.gl.com 1 Playback File

More information

Configuration of Synchronous Protocols

Configuration of Synchronous Protocols encor! enetworks TM Version A, September 2010 2013 Encore Networks, Inc. All rights reserved. Configuration of Synchronous Protocols This chapter discusses synchronous protocols that you can configure

More information

HDLC-USB. Portable Protocol Converter. Rev. Dec 25, Datasheet. Website:

HDLC-USB. Portable Protocol Converter. Rev. Dec 25, Datasheet.   Website: HDLC-USB Portable Protocol Converter Rev. Dec 25, 2017 HDLC-USB Datasheet Email: yacer@yacer.cn Website: www.yacer.cn 1 Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Applications... 3 1.4 Technical

More information

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units Data Sheet FCD-E1LC, FCD-T1LC Managed TDM multiplexers for access to full or fractional E1/T1 services Managed access units for E1/T1 or fractional E1/T1 service E1/T1 main link and sublink support framed

More information

Flexible multiplexer E1XL

Flexible multiplexer E1XL E1XL Multiplexer User Manual 123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123456789012 Flexible multiplexer E1XL Rev. D Features Two E1 links (PCM-30)

More information

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO F8016 Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO Description The fiber transmission platform is a fiber optic multiplexer with a fully new designing concept to challenge

More information

HDLC-ETH. Serial Ethernet Converter. Rev. Dec 20, Datasheet. Website:

HDLC-ETH. Serial Ethernet Converter. Rev. Dec 20, Datasheet.   Website: HDLC-ETH Serial Ethernet Converter Rev. Dec 20, 2017 HDLC-ETH Datasheet Email: yacer@yacer.cn Website: www.yacer.cn 1 Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Applications... 3 1.4 Technical

More information

Multiplexing cross-connector E1-DXC

Multiplexing cross-connector E1-DXC E1-DXC Cross-connector User s Guide 123456789012345678901234567890121234567890123456789012345678901212345678901234567890123456789012123 Multiplexing cross-connector E1-DXC Features Desktop or the card

More information

Configuring T1/E1 Interfaces

Configuring T1/E1 Interfaces This chapter provides information about configuring the T1/E1 interface module on the chassis. It includes the following sections: For information about managing your system images and configuration files,

More information

V C ALIANT OMMUNICATIONS. VCL-EC E1 Echo Canceller 1U, 19 inch Version with Telnet E1, 1U Echo Canceller Product Brochure & Data Sheet

V C ALIANT OMMUNICATIONS. VCL-EC E1 Echo Canceller 1U, 19 inch Version with Telnet E1, 1U Echo Canceller Product Brochure & Data Sheet V C ALIANT OMMUNICATIONS TM VCL-EC E1 Echo Canceller 1U, 19 inch Version with Telnet E1, 1U Echo Canceller Product Brochure & Data Sheet U.K. Valiant Communications (UK) Ltd 1, Acton Hill Mews, 310-328

More information

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES -2100/2104,, and LAN Integrating Modular Multiplexer FEATURES Modular integrating access multiplexer for data, voice, fax and LAN Advanced voice compression techniques maximize utilization of main link

More information

Configuring Cisco Integrated Data Service Unit/Channel Service Unit (DSU/CSU) Modules and WAN Interface Cards

Configuring Cisco Integrated Data Service Unit/Channel Service Unit (DSU/CSU) Modules and WAN Interface Cards Configuring Cisco Integrated Data Service Unit/Channel Service Unit (DSU/CSU) Modules and WAN Interface Cards Document ID: 10265 Interactive: This document offers customized analysis of your Cisco device.

More information

4xT1/E1 i nline probe ASE With LinkSafe capabilities

4xT1/E1 i nline probe ASE With LinkSafe capabilities Visual UpTime Select ASE model 807-0115 4xT1/E1 i nline probe ASE With LinkSafe capabilities Key features Four management ports MLPPP support on IP Transport software Inband management capability LinkSafe

More information

E1/DS1/DTE IP 6610 Router/Bridge Box

E1/DS1/DTE IP 6610 Router/Bridge Box E1/DS1/DTE IP 6610 Router/Bridge Box Description Features Support 1 or 4 Ethernet LAN ports The IP 6610 Router/Bridge provides connectivity from 10/100 BaseT LAN to E1/ DS1/ DTE WAN in a small metal box.

More information

ERM-Mux/Plus. 4U, 10 I/O Slot Data, Ethernet, Voice E1 Managed Multiplexer. E1 Access Multiplexer. ERM-Mux/Plus.

ERM-Mux/Plus. 4U, 10 I/O Slot Data, Ethernet, Voice E1 Managed Multiplexer. E1 Access Multiplexer. ERM-Mux/Plus. Access Multiplexer 4U, 10 I/O Slot Data,, Voice Managed Multiplexer The ERM-Mux/plus is a 4U 19(23)" 14 slot rack type Time Division Multiplexer for Fractional network access which is designed for non-stop

More information

HDLC-PCIE. Synchronous Serial Card. Rev. Dec 22, Datasheet. Website:

HDLC-PCIE. Synchronous Serial Card. Rev. Dec 22, Datasheet.   Website: HDLC-PCIE Synchronous Serial Card Rev. Dec 22, 2017 HDLC-PCIE Datasheet Email: yacer@yacer.cn Website: www.yacer.cn 1 Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Driver Support... 3 1.4 Applications...

More information

The Puma 4000 Series. A World of Good for Your Networks. Analysis of E1 PCM Circuits. Applications. Live Monitoring of Mbit/s Circuits

The Puma 4000 Series. A World of Good for Your Networks. Analysis of E1 PCM Circuits. Applications. Live Monitoring of Mbit/s Circuits The Puma 4000 Series The Puma 4000 is the ultimate field portable analyser for installing, maintaining and testing 2.048 Mbits/s PCM and data communications circuits. No other test set comes with as many

More information

DXC 5000 PRODUCT DESCRIPTION

DXC 5000 PRODUCT DESCRIPTION Product Description DXC5K/EN HW/A22 DXC 5000 PRODUCT DESCRIPTION Production Description DXC5K/EN HW/A22 DXC 5000 Page 1/26 CONTENTS 1. INTRODUCTION 5 2. DESCRIPTION 6 2.1 Functional description 6 2.2

More information

Vmux-110. Voice Trunking Gateway FEATURES

Vmux-110. Voice Trunking Gateway FEATURES Vmux-110 FEATURES Integrates voice and data over packet networks Connects one E1/T1 digital or four/eight (FXS/FXO/E&M) analog voice ports over a serial, TDM or 10/100BaseT uplink Second Ethernet port

More information

Kilomux-2100/2104 KVF.6 E1/T1 Voice Compression Module

Kilomux-2100/2104 KVF.6 E1/T1 Voice Compression Module Data Sheet Kilomux-2100/2104 KVF.6 Half or full PBX E1/T1 trunk compression Up to 186 voice channels in a single Kilomux-2100 chassis Group III Fax relay at up to 14.4 kbps, with automatic rate fallback

More information

Section 4.1, ISDN in the SP201-SA. Section 4.2, Command for Configuring ISDN Protocols. Section 4.3, Configuring ISDN Signaling

Section 4.1, ISDN in the SP201-SA. Section 4.2, Command for Configuring ISDN Protocols. Section 4.3, Configuring ISDN Signaling Chapter 4 Configuration of ISDN Protocols This chapter provides instructions for configuring the ISDN protocols in the SP201-SA for signaling conversion. Use the sections that reflect the software you

More information

Lecture-65 SERIAL DATA COMMMUNICATION The data bus of a microcomputer system is designed to transfer data to and from I/O device in parallel - all

Lecture-65 SERIAL DATA COMMMUNICATION The data bus of a microcomputer system is designed to transfer data to and from I/O device in parallel - all Lecture-65 SERIAL DATA COMMMUNICATION The data bus of a microcomputer system is designed to transfer data to and from I/O device in parallel - all bits of a data word are transformed simultaneously. This

More information

NetVanta Series (with E1/FE1 or E1/FE1 with G.703 Drop Network Interface Module)

NetVanta Series (with E1/FE1 or E1/FE1 with G.703 Drop Network Interface Module) VPN WAN LAN PWR STAT TD RD TD RD TD RD VPN WAN LAN PWR STAT TD RD TD RD TD RD NetVanta 3200 NetVanta 3200 NetVanta Series (with E1/FE1 or E1/FE1 with G.703 Drop Network Interface Module) Quick Configuration

More information

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES Modular integrating access multiplexer for data, voice, fax and LAN Maximized utilization of main-link bandwidth and high quality low bit

More information

LOOP-AM 3440 Access DCS-MUX

LOOP-AM 3440 Access DCS-MUX Access DCS-MUX LOOP-AM 3440 Access DCS-MUX Description Features : Support DACS (Digital Access Cross-connect System) with full cross-connect Support full DS0 cross-connect, backplane capacity up to 128

More information

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer Data Sheet Kilomux-2100/2104 Data, Voice, Fax and LAN Integrating Modular Multiplexer Maximized utilization of main-link bandwidth and high-quality low bit rate voice Fractional E1/T1, switched or leased

More information

Concept Questions Demonstrate your knowledge of these concepts by answering the following questions in the space provided.

Concept Questions Demonstrate your knowledge of these concepts by answering the following questions in the space provided. 123 Chapter 10 WANs and Routers One major characteristic of a wide-area network (WAN) is that the network operates beyond the local LAN's geographic scope. It uses the services of carriers, such as regional

More information

D2500 TELECOM ANALYZER FEATURES AT A GLANCE OVERVIEW. ISDN & Telecom standards On board support for multiple protocols

D2500 TELECOM ANALYZER FEATURES AT A GLANCE OVERVIEW. ISDN & Telecom standards On board support for multiple protocols D2500 TELECOM ANALYZER ISDN & Telecom standards On board support for multiple protocols WAN & DATACOM Leased line & Datacom Pre-Qualification Testing Flexible Operation Control all Functions locally or

More information

ACCESS MUX CROSS CONNECT

ACCESS MUX CROSS CONNECT TDM PDH DACS QX3440-D DACS (Digital Access Cross-connect System) with full DS0 non blocking cross-connect with up to 72Mbps capacity Up to 36E1/T1 WAN Full modular system: - 2 slots controller CPU, - 2

More information

Lecture (04 & 05) Packet switching & Frame Relay techniques Dr. Ahmed ElShafee

Lecture (04 & 05) Packet switching & Frame Relay techniques Dr. Ahmed ElShafee Agenda Lecture (04 & 05) Packet switching & Frame Relay techniques Dr. Ahmed ElShafee Packet switching technique Packet switching protocol layers (X.25) Frame Relay ١ Dr. Ahmed ElShafee, ACU Fall 2011,

More information

Lecture (04 & 05) Packet switching & Frame Relay techniques

Lecture (04 & 05) Packet switching & Frame Relay techniques Lecture (04 & 05) Packet switching & Frame Relay techniques Dr. Ahmed ElShafee ١ Dr. Ahmed ElShafee, ACU Fall 2011, Networks I Agenda Packet switching technique Packet switching protocol layers (X.25)

More information

Multiplexer FMUX/SAT. 4 x E1 ports V.35/RS-530/RS-449 link interface in codirectional mode. Installation and Operations Manual

Multiplexer FMUX/SAT. 4 x E1 ports V.35/RS-530/RS-449 link interface in codirectional mode. Installation and Operations Manual Multiplexer FMUX/SAT 4 x E1 ports V.35/RS-530/RS-449 link interface in codirectional mode Installation and Operations Manual Document version: 1.7E / 06.09.2006 FMUX/SAT Multiplexer Safety Precautions

More information

isap5100 STM1/E1, Data, Ethernet, Voice Managed Multiplexer (4U)

isap5100 STM1/E1, Data, Ethernet, Voice Managed Multiplexer (4U) STM1/ Managed Multiplexer STM1/,,, Voice Managed Multiplexer (4U) The is a 4U 19 20 slots rack type STM1 / Time Division Multiplexer for fractional network access, which is designed for non-stop operation.

More information

G.SHDSL.Bis NTU. User Manual. Version 0.03

G.SHDSL.Bis NTU. User Manual. Version 0.03 G.SHDSL.Bis NTU User Manual Version 0.03 July 2008 Tables of Contents 1. INTRODUCTION... 3 1.1 FEATURES... 4 1.2 SPECIFICATION... 4 1.3 APPLICATIONS... 6 2. GETTING TO KNOW ABOUT THE SHDSL.BIS NTU... 7

More information

DM16E1 Series II DM4E1 Series II

DM16E1 Series II DM4E1 Series II DM16E1 Series II DM4E1 Series II Optical PDH Multiplexers Dec-2013 General Presentation The DM16E1 Series II and DM4E1 Series II are PDH multiplexers according G.751 e G.742. Operate with E1 multiplexer

More information

Signal loss alarm, AIS alarm, framed remote alarm, multi-framed remote alarm, out-of-frame, and pattern loss alarm

Signal loss alarm, AIS alarm, framed remote alarm, multi-framed remote alarm, out-of-frame, and pattern loss alarm Major Features LCD large-screen display, 320*240 lattice, backlight, LED indicator Hand held, auto configuration Multi-task operation at one time Store 20 test results and 9 test configurations, with power-off

More information

Vmux-210 Analog Voice Trunking Gateway

Vmux-210 Analog Voice Trunking Gateway Where to buy > See the product page > Unique TDMoIP multiplexing, together with various voice compression algorithms, provides up to 16:1 compression for effective bandwidth utilization Fully transparent

More information

ALBEDO Ether.Genius khz 2048 khz kb/s 2048 kb/s. 10 MHz 2. ETHERNET 2.1. ETHERNET PHY

ALBEDO Ether.Genius khz 2048 khz kb/s 2048 kb/s. 10 MHz 2. ETHERNET 2.1. ETHERNET PHY the Path to Excellence ALBEDO Ether.Genius ALBEDO Ether.Genius is a multitechnology Ethernet tester to install and troubleshoot telecom services based on GbE, SyncE, PTP, Jitter, Wander, E1, IEEE C37.94,

More information

Implementing Enterprise WAN Links

Implementing Enterprise WAN Links Implementing Enterprise WAN Links Introducing Routing and Switching in the Enterprise Chapter 7 Version 4.0 1 Objectives Describe the features and benefits of common WAN connectivity options. Compare and

More information

FCD-E1, FCD-T1 E1/T1 or Fractional E1/T1 Access Units

FCD-E1, FCD-T1 E1/T1 or Fractional E1/T1 Access Units FCD-E1, FCD-T1 Access units for E1/T1 or fractional E1/T1 services Several data ports with selectable sync data rates: n 56/64 kbps Optional sub-e1/t1 drop-and-insert port for PBX connectivity Fail-safe

More information

Teldat Router G.703 Interface. User Manual

Teldat Router G.703 Interface. User Manual Teldat Router G.703 Interface User Manual Rev. 10.11 June, 2003 INDEX Chapter 1 Introduction...1 1. Description... 2 2. Installation... 5 2.1. RJ45 Connector... 5 2.2. Coaxial connector... 5 Chapter 2

More information

RION ORION TELECOM NETWORKS INC. VCL-EC T1 Echo Canceller 1U, 19 inch Version with Telnet. T1, 1U Echo Canceller Product Brochure & Data Sheet

RION ORION TELECOM NETWORKS INC. VCL-EC T1 Echo Canceller 1U, 19 inch Version with Telnet. T1, 1U Echo Canceller Product Brochure & Data Sheet RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. TM VCL-EC T1 Echo Canceller 1U, 19 inch Version with Telnet T1, 1U Echo Canceller Product Brochure & Data Sheet Headquarters: Phoenix, Arizona Address:

More information

IPmux-1E. TDMoIP Gateway FEATURES

IPmux-1E. TDMoIP Gateway FEATURES IPmux-1E FEATURES TDMoIP gateway enabling E1, T1, ISDN, and analog phone communication over asynchronous IP and Ethernet networks Framed (full or fractional) and unframed E1/T1 user traffic Four FXS/E&M/FXO

More information

Multichannel STM-1 Port Adapter for the Cisco 7500 Series Router

Multichannel STM-1 Port Adapter for the Cisco 7500 Series Router Multichannel STM-1 Port Adapter for the Cisco 7500 Series Router This feature module describes the Multichannel STM-1 Port Adapter (PA-MC-STM-1). It includes information on the benefits of this port adapter,

More information

E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router Data Sheet E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router Modular Integrated Access Device (IAD), providing bundled data, IP and telephony services over E1/T1 access lines E1/T1

More information

Configuring T1/E1 Interfaces

Configuring T1/E1 Interfaces Effective Cisco IOS-XE Release 3.14.0S, the Cisco ASR-920-24SZ-IM, ASR-920-24SZ-M, ASR-920-24TZ-M Aggregation Services Router supports the following types of interface modules (IMs): 8x1G Cu IM (A900-IMA8T)

More information

ISDN TEST EQUIPMENT ISDN. aurora Duet. Hand Held Testing for Primary & Basic Rate ISDN TREND COMMUNICATIONS

ISDN TEST EQUIPMENT ISDN. aurora Duet. Hand Held Testing for Primary & Basic Rate ISDN TREND COMMUNICATIONS ISDN TEST EQUIPMENT aurora Duet ISDN Hand Held Testing for Primary & Basic Rate ISDN TREND COMMUNICATIONS aurora Duet The aurora Duet has been designed to provide the ISDN engineer with the right tool

More information

Configuring Synchronized Clocking

Configuring Synchronized Clocking Configuring Synchronized Clocking This appendix describes how to configure synchronized clocking. It contains the following sections: Synchronized Clocking Overview, page 791 Synchronized Clocking Configuration

More information

Communication Networks

Communication Networks Communication Networks Chapter 3 Multiplexing Frequency Division Multiplexing (FDM) Useful bandwidth of medium exceeds required bandwidth of channel Each signal is modulated to a different carrier frequency

More information

Module 3. Wide Area Networking (WAN)

Module 3. Wide Area Networking (WAN) Module 3 Wide Area Networking (WAN) When many nodes or LAN s are connected together in a large scale, we have a WAN. This may be world wide. Because of the separation of the nodes, the Public Data Network

More information

CCNA 4 - Final Exam (A)

CCNA 4 - Final Exam (A) CCNA 4 - Final Exam (A) 1. A network administrator is asked to design a system to allow simultaneous access to the Internet for 250 users. The ISP for this network can only supply five public IPs. What

More information

Cisco 4000 Series Integrated Services Router T1/E1 Voice and WAN Network Interface Modules Data Sheet

Cisco 4000 Series Integrated Services Router T1/E1 Voice and WAN Network Interface Modules Data Sheet Data Sheet Cisco 4000 Series Integrated Services Router T1/E1 Voice and WAN Network Interface Modules Data Sheet These flexible interface cards support multiple integrated data and voice applications,

More information

3630 MAINSTREET. Intelligent, high perfomance multiplexing that terminates up to 31 voice or data circuits. PRIMARY RATE MULTIPLEXER Release 5.

3630 MAINSTREET. Intelligent, high perfomance multiplexing that terminates up to 31 voice or data circuits. PRIMARY RATE MULTIPLEXER Release 5. 3630 MAINSTREET PRIMARY RATE MULTIPLEXER Release 5.3 Alcatel s 3630 MainStreet Primary Rate Multiplexer (PRM) serves as a gateway on the customer premises to primary rate facilities for a wide range of

More information

Version 1.1. User's Manual

Version 1.1. User's Manual Version 1.1 User's Manual Contents Overview...3 Features...4 Applications...4 Specifications...5 Packing...6 Appearance...7 Front Panel...7 Rear Panel...8 Important Safety Instructions...9 Installation...

More information

Using an ADTRAN Terminal Adapter with Cisco Routers

Using an ADTRAN Terminal Adapter with Cisco Routers Using an ADTRAN Terminal Adapter with Cisco Routers Document ID: 28080 Contents Introduction Prerequisites Requirements Components Used Conventions Dialing Method V.25 or V.25bis Dialing DTR Dialing Keypad

More information

Datasheet. RC3000E Multi Service Access Node. Chassis. Uplink Cards. Specification. Downlink Cards. Raisecom Technology Co., Ltd.

Datasheet. RC3000E Multi Service Access Node. Chassis. Uplink Cards. Specification. Downlink Cards. Raisecom Technology Co., Ltd. RC3000E Multi Service Access Node Raisecom s RC3000E is a compact and cost-effective with the ability to access 30 channels voice intelligent multi service access multiplexer. It can provide maximum 8E1

More information

VCL-CB RION. Intelligent E1 Channel Bank ORION TELECOM NETWORKS INC. Product Brochure & Data Sheet TELECOM NETWORKS. Headquarters: Phoenix, Arizona

VCL-CB RION. Intelligent E1 Channel Bank ORION TELECOM NETWORKS INC. Product Brochure & Data Sheet TELECOM NETWORKS. Headquarters: Phoenix, Arizona RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. VCL-CB TM Intelligent E1 Channel Bank Product Brochure & Data Sheet Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100, N 51st Ave, Suite

More information

Lecture (08) Fundamentals of WANs (II)

Lecture (08) Fundamentals of WANs (II) Agenda Lecture (08) Fundamentals of WANs (II) OSI Layer 2 of WANs ATM & SONET WAN Dr. Ahmed M. ElShafee ١ ٢ OSI Layer 2 of WANs OSI Layer 2 of WANs (2) WAN protocols used on point to point serial links

More information

InterPrise 3200D. An IP Telephony Gateway for Enterprise Network Applications

InterPrise 3200D. An IP Telephony Gateway for Enterprise Network Applications InterPrise 3200D An IP Telephony Gateway for Enterprise Network Applications Table of Contents Overview... 3 Ease of Integration... 3 Quality Voice Communication... 3 Web-based Calling with ClearConnect

More information

ORION TELECOM NETWORKS INC.

ORION TELECOM NETWORKS INC. RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. TM VCL-EC T1 Echo Canceller Desktop Version (Modem Type) Desktop T1 Echo Cancellers Product Brochure & Data Sheet Headquarters: Phoenix, Arizona 20100,

More information

Take testing to the next level

Take testing to the next level ACTERNA TEST & MEASUREMENT SOLUTIONS JDSU Fireberd 8000 Specs FIREBERD 8000 Provided by www.aaatesters.com Take testing to the next level Key Features Datacomm interfaces in one test module for ANSI and

More information

multiplexers & interface converters

multiplexers & interface converters PRODUCTS OVERVIEW 2004-2005 INTERFACE CONVERSION, DIGITAL CROSS CONNECTS (DXC) AND MULTIPLEXING ALLOW THE OPTIMISATION OF THE ACCESS INFRASTRUCTURE BY ITS ABILITY TO DO LOCAL SWITCHING, TO REDUCE THE NUMBER

More information

HDLC (High level Data Link Control)

HDLC (High level Data Link Control) High-level Data Link Control HDLC (High level Data Link Control) Modem, EIA-232, HDLC Framing and Procedures Agenda Line Management, Modems Introduction HDLC Station Types, Modes of Operation Frame Format,

More information

Line Protocol Basics. HDLC (High level Data Link Control) Agenda. Additional Issues

Line Protocol Basics. HDLC (High level Data Link Control) Agenda. Additional Issues Line Protocol Basics High-level Data Link Control HDLC (High level Data Link Control), EIA-232, HDLC Framing and Procedures line protocol basics already explained serial transmission techniques bit-synchronization

More information

Chapter 4 Front Panel Option Selection

Chapter 4 Front Panel Option Selection Chapter 4 Front Panel Option Selection GENERAL FT 100 configuration options, operating status, and diagnostics can be observed or changed using the front panel pushbuttons with the LCD. The unit can also

More information

HP MSR Router Series. Interface Configuration Guide(V7) Part number: a Software version: CMW710-R0106 Document version: 6PW

HP MSR Router Series. Interface Configuration Guide(V7) Part number: a Software version: CMW710-R0106 Document version: 6PW HP MSR Router Series Interface Configuration Guide(V7) Part number: 5998-6361a Software version: CMW710-R0106 Document version: 6PW101-20140807 Legal and notice information Copyright 2014 Hewlett-Packard

More information

Data and Computer Communications

Data and Computer Communications Data and Computer Communications Chapter 10 Circuit Switching and Packet Switching Eighth Edition by William Stallings Lecture slides by Lawrie Brown Circuit Switching and Packet Switching He got into

More information

Circuit Emulation over IP

Circuit Emulation over IP (CEoIP) provides a virtual circuit through an IP network--similar to a leased line--to integrate solutions that require a time-sensitive, bit-transparent transport into IP networks. Data, with proprietary

More information

LOOP-E CSU/DSU MODEL S (Stand Alone with Inband) USER'S MANUAL

LOOP-E CSU/DSU MODEL S (Stand Alone with Inband) USER'S MANUAL LOOP-E CSU/DSU MODEL 1500-2S (Stand Alone with Inband) USER'S MANUAL LOOP TELECOMMUNICATION INTERNATIONAL, INC. 8F, NO. 8, HSIN ANN RD. SCIENCE-BASED INDUSTRIAL PARK HSINCHU, TAIWAN Tel: +886-3-578-7696

More information

ASMi-52. 2/4-Wire SHDSL Modem FEATURES

ASMi-52. 2/4-Wire SHDSL Modem FEATURES FEATURES Dedicated managed SHDSL modem Operates over 2-wire and 4-wire lines, enabling service over any copper infrastructure Multiplexes of two data streams (E1, Ethernet, Serial) over SHDSL Utilizes

More information

LCM-160. Low-Power Embedded Communication Module. Rev. Dec 26, LCM-160 Datasheet. Website:

LCM-160. Low-Power Embedded Communication Module. Rev. Dec 26, LCM-160 Datasheet.   Website: LCM-160 Low-Power Embedded Communication Module Rev. Dec 26, 2017 LCM-160 Datasheet Email: yacer@yacer.cn Website: www.yacer.cn 1 Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Applications...

More information

Datasheet. RC3000E Multi Service Access Node. Chassis. Uplink Cards. Specification. Downlink Cards. Raisecom Technology Co., Ltd.

Datasheet. RC3000E Multi Service Access Node. Chassis. Uplink Cards. Specification. Downlink Cards. Raisecom Technology Co., Ltd. RC3000E Multi Service Access Node Raisecom s RC3000E is a compact and cost-effective with the ability to access 30 channels voice intelligent multi service access multiplexer. It can provide maximum 8E1

More information

Protocol/interface converter series

Protocol/interface converter series Protocol/interface converter series E1 to 10Base-T Protocol Converter 4E1 to 10/100Mbps Ethernet Protocol Converter 8E1 to 10/100Mbps Ethernet Protocol Converter E1 to V.35 Protocol Converter Protocol

More information

Frame Relay. Frame Relay Information 1 of 18

Frame Relay. Frame Relay Information 1 of 18 Frame Relay Information 1 of 18 This document was retrieved from the Web and has been been edited by Thomas Jerry Scott for use in his TCP/IP network classes. Chapter Goals Describe the history of Frame

More information

Overview encapsulation hdlc show interface show controllers show interface debug PPP

Overview encapsulation hdlc show interface show controllers show interface debug PPP PPP CCNA 4 Overview Explain serial communication Describe and give an example of TDM Identify the demarcation point in a WAN Describe the functions of the DTE and DCE Discuss the development of HDLC encapsulation

More information

IPmux-1E TDM Pseudowire Access Gateway

IPmux-1E TDM Pseudowire Access Gateway Data Sheet IPmux-1E TDM circuit emulation over packet-switched networks Transporting E1, T1, ISDN and analog phone traffic over packet-switched networks Four FXS, FXO or E&M voice ports for standard analog

More information

isap2000 E1, Data, Ethernet, Voice Managed Multiplexer (2U)

isap2000 E1, Data, Ethernet, Voice Managed Multiplexer (2U) Managed Multiplexer,,, Voice Managed Multiplexer (2U) The is a 2U 19 6 slots rack type Time Division Multiplexer for fractional network across, which is designed for nonstop operation. There are 6 slots

More information

Overview. Port Adapter Overview CHAPTER

Overview. Port Adapter Overview CHAPTER CHAPTER This chapter describes the PA-MC-E/ and PA-MC-8E/ port adapters and contains the following sections: Port Adapter, page - Features, page -4 Compliance and Electrical Interface Specifications for

More information

ATM Technology in Detail. Objectives. Presentation Outline

ATM Technology in Detail. Objectives. Presentation Outline ATM Technology in Detail Professor Richard Harris Objectives You should be able to: Discuss the ATM protocol stack Identify the different layers and their purpose Explain the ATM Adaptation Layer Discuss

More information

FCD-E1E Managed E1 and Fractional E1 Access Device

FCD-E1E Managed E1 and Fractional E1 Access Device FCD-E1E E1 main link and sublink supporting both framed and unframed signals One data port with selectable sync data rates of n 64 kbps Optional sub-e1 drop-and-insert port Optional Ethernet 10/100BaseT

More information

Loop-IP6700 TDMoEthernet

Loop-IP6700 TDMoEthernet Loop-IP6700 TDMoEthernet Description Features 1U height WAN port: one electric Ethernet (10/100 BaseT) or optical Ethernet (10/100 Base-FX) Tributary ports TDM interfaces low speed, up to 4 E1/T1 low speed,

More information

ASMi-52 2/4-wire SHDSL Modem/Multiplexer

ASMi-52 2/4-wire SHDSL Modem/Multiplexer Where to buy > See the product page > Data Sheet ASMi-52 Plastic Enclosure Metal Enclosure Rail-mount Metal Enclosure Dedicated managed SHDSL modem for Ethernet, E1 and serial services over 2- or 4-wire

More information

Product Overview Brochure. CMA 3000 All-In-One Field Tester for Fixed and Mobile Networks

Product Overview Brochure. CMA 3000 All-In-One Field Tester for Fixed and Mobile Networks Product Overview Brochure CMA 3000 All-In-One Field Tester for Fixed and Mobile Networks E1 or E1 in SDH with A-bis signaling - Ethernet in future E1 or E1 in SDH with SS7 (Ainterface) signaling - Ethernet

More information

PSEUDOWIRE PERFORMANCE

PSEUDOWIRE PERFORMANCE Legacy over PSN solution for transmitting E1 streams over packet switched networks Comprehensive compliance with pseudowire/circuit emulation standards including TDMoIP, CESoPSN, SAToP and HDLCoPSN Built

More information

Lecture 15: Multiplexing (2)

Lecture 15: Multiplexing (2) Lecture 15: Multiplexing (2) Last Lecture Multiplexing (1) Source: chapter 8 This Lecture Multiplexing (2) Source: chapter8 Next Lecture Circuit switching (1) Source: chapter9 Digital Carrier Systems Hierarchy

More information

Vmux-110 Voice Trunking Gateway for Remote Sites

Vmux-110 Voice Trunking Gateway for Remote Sites Where to buy > See the product page > Data Sheet Vmux-110 Compressing one E1/T1 or four/eight analog (FXS/FXO/E&M) voice ports, and transmitting them over a serial, fractional E1/T1, or a 10/100BaseT uplink

More information

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

Actual4Test.   Actual4test - actual test exam dumps-pass for IT exams Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : 350-025 Title : CCIE Service Provider Dial Vendors : Cisco Version : DEMO Get Latest & Valid 350-025

More information