Emergency. Lighting. CATALOGUE Vol. 01. Decentralised and centralised supply

Size: px
Start display at page:

Download "Emergency. Lighting. CATALOGUE Vol. 01. Decentralised and centralised supply"

Transcription

1 Emergency CATALOGUE Vol. 01 Lighting Decentralised and centralised supply

2

3 Light is safety Light must be safe! Interior luminaire, exterior luminaire and emergency luminaire are all important to ensure safety. This is why light must be safe. But light should be more than that. And luminaire from Beghelli PRÄZISA truly is more than that. It is: efficient SmartLuminaire and SicuroEmergencyLuminaire are based on extremely efficient products and solutions for reducing power consumption during both mains and battery operation by up to 75%and the number of luminaires by up to 40%. You make additional savings because the products are quick to installand also easy to maintain. universal Plug & Use SmartDriver as 1for5 LED driver for LED luminaires with interfaces for optional radio module, DALI module, 1-10V module, sensor module and emergency light module.... proven We have been supplying radio controllers for dimming, controlling and monitoring of complex general and emergency luminaire systems via radio communication according to the Zigbee standard for more than 15 years. simple OptiCom for dimming, controlling and monitoring of general and emergency luminaire systems with a smartphone app using optical communication. innovative Lithium ion titanate technology as a battery for self contained emergency luminaire for extreme ambient temperatures from - 25 to + 50 C, a long life of 10 years and rapid recharge in just 2 hours. Thanks to this concept, Beghelli PRÄZISA has long been a trusted partner for technical designers, specialist contractors, industry, tradeand commerce. As a part of the Beghelli Group, which is active around the world, we are specialised in developing, manufacturingand selling general luminaire, emergency luminaireand luminaires.

4 4 Content page Advantages decentralised supply Sicuro24 6 Luminaires for decentralised supply Sicuro24 8 Decentralised supply Sicuro24- general chart 10 Compact station Sicuro24 12 Optional components for Sicuro24 14 Advantages centralised supply NZBVA and NZBVE 16 Central supply NZBVA and NZBVE 18 Central station NZBVA-Z 20 Central station NZBVE-Z 21 Central station NZBVE-Z Kombi 22 Sub-station NZBVA-U and NZBVE-U 23 Compact sub-station eak 24 Junction box 24 Central supply NZBVE-Mini 25 Centralised supply - general chart 26 Tecnical data of the batteries 28 Battery management system Life Plus 29 Luminaire circuit assemblies 30 Monitoring and switching modules 32 Optional system components 33

5 Content page Optional components for NZBVA and NZBVE 34 Optional components for Sicuro24, NZBVA and NZBVE 36 Monitoring and control software Logica Visual 36 Signalling and switching modules 37

6 6 Advantages decentralised supply Sicuro24 Supply of the emergency luminaire in a fire zone of a building. System consisting of compact station with battery, charger, power supply, control and monitoring and distribution board with 4 luminaire circuits. Compact station in the combined cabinet with separate battery part. Concept with separate components for charging, control and monitoring, power supply and luminaire circuits, individually replaceable. Battery as sealed Pb battery with a service life of > 10 years.

7 7 Automatic test equipment for carrying out function and service life tests and saving the test results. Dynamic control for safety cables for risk-dependent change of the escape route marking and illumination. Optional central monitoring by a PC via an intranet and optional Logica Visual software or internet using Sicuro Web or connection to a building management system via modbus. Test functions: manual function test (Start) output of test results Control functions: stand by mode (On/Off) maintained mode (On/Off) Message functions: assignment of the systems and circuits and the operating mode per circuit status and faults in online mode per system or circuit Luminaire circuits with 24V system voltage (mains and battery operation) with the following functions: operation of separate escape route and emergency luminaires with integrated Sicuro24 module for monitoring and control operation of combined general and emergency luminaires with separate Sicuro24 inverter for monitoring, control and power reduction in battery mode automatic addressing of Sicuro24 modules and Sicuro24 inverter programmable maintained or non-maintained mode switch per luminaire combinable maintained and non-maintained mode switch in one luminaire circuit selective dimming (10-100%) per luminaire in mains mode selective switch (On/Off) per luminaire in mains mode selective switch (On/Off) per luminaire in emergency operation automatic test of all luminaires in one circuit with fault message per luminaire

8 8 Luminaires for decentralised supply Sicuro24 On a decentralized supply Sicuro24 can be operated: Separate emergency luminaires with integrated Sicuro24 module for monitoring and control of the luminaires. In addition also versions for installation in accessory sockets approved for construction by DIBt for fire protection ceilings with a fire resistance class F30 or F90n. Separate exit sign luminaires with integrated Sicuro24 module for monitoring and control of the luminaires. In addition also versions for installation in accessory sockets approved for construction by DIBt for fire protection ceilings or fire protection walls with a fire resistance class F30 or F90n. Combined general and emergency luminaires with integrated Sicuro24 inverter for monitoring and control of the luminaires and additional reduction of the output in battery mode to 6 W or 12 W. For these variants the lamp LED module is operated in mains mode at 230 V AC via the LED operating unit with nominal output and in battery mode at 24 V DC via the Sicuro24 inverter with a reduced output.

9 9 Advantages of combined general and emergency luminaires with the Sicuro24 inverter reduced luminaire output with the same number of lamps smaller batteries smaller chargers compact systems for supply of emergency lighting low costs for batteries and chargers Example Lighting of an escape route (30 m x 2 m) with luminaire of higher protection class with and without output reduction through a Sicuro24 inverter : Illuminance E min : 1.0 lx Uniformity of the illuminance g: > without Sicuro24 inverter with Sicuro24 inverter illuminance E m lx 18.0 lx uniformity g number of luminaires n L 2 2 connected load P L 148 W 16 W The output reduction is 89.1 % Example Lighting of an escape route (30 m x 2 m) with luminaire of higher protection class with and without output reduction through a Sicuro24 inverter : Illuminance E min : 0.5 lx Uniformity of the illuminance g: > without Sicuro24 inverter with Sicuro24 inverter illuminance E m 47.0 lx 8.0 lx uniformity g number of luminaires n L 2 2 connected load P L 72 W 16 W The output reduction is 77.8 % Combined general and emergency luminaires with integrated Sicuro24 inverter can be panel luminaires, lens luminaires, louvre luminaires, downlights, round luminaires, higher protection class luminaires and higher protection class spotlights.

10 10 Decentralised supply Sicuro Central station Exit sign luminaires with S24 module Emergency luminaires with S24 module Combined general and emergency luminaires with S24 inverter Mains monitoring module (option) - cable: min. 2 x 2 x 0.8 mm Combined mains monitoring / light switch query module (option) cable: min. 2 x 2 x 0.8 mm + min. 1 x 2 x 1.5 mm Signalling or switching module (option) - cable: min. 6 x 2 x 0.8 mm (RS485) RS485 bus or Ethernet bus for remote panel (option) - cable: min. 2 x 2 x 0.8 mm / min. CAT 5 (Ethernet)

11 USB interface (option) or Ethernet bus for PC with Logica-Visual software - cable: min. 2 x 2 x 0.8 mm / CAT 5 (Ethernet) Ethernet bus for web server - cable: min. CAT 5 RS485 bus for modbus RTU: min. 2 x 2 x 0.8 mm 230 V AC 24 V DC RS485 bus Ethernet

12 12 Compact station Sicuro24 Control and monitoring with: automatic test equipment acc. to DIN EN for carrying out function and service life tests and saving the test results dynamic light control for risk-dependent emergency lighting, change of the escape route luminaires and lighting Luminaire circuit: 4 luminaire circuits in protection class III for maximum 20 luminaires per circuit output per circuit: max. 72 W voltage / current per circuit: 24 V / 3 A Mains monitoring device: internal mains monitoring device control input for optional mains monitoring device Control input: 4 control inputs, freely programmable, for switching the luminaires, control signal 230 V AC Switching input and signal output: 1 switching input, fixed programmed, for switching the maintained mode (On/Off), switching signal contact, potential free 1 switch input, freely programmable, for switching from stand by mode (On/Off) function test (Start) / duration test (Start) / non-maintained mode switch (Off), deep discharge (acknowledge), switching signal: contact, potential free 3 signal outputs, permanently programmed, for message from group fault / stand by mode / battery mode, status signal: contact, potential free 3 signal outputs, freely programmable, for message of status of charge / battery / circuit / luminaire / stand by mode / mains failure / battery mode / test mode / deep discharge, status signal: contact, potential free RS485 interface for external light switch query modules Communication bus and interfaces: RS485 bus for communication with optional Logica Visual software or an optional remote panel or a building management systems via modbus function via modbus: message from system configurations, system status and faults ethernet bus for communication via the internet with a web server or an intranet to a PC with optional Logica Visual Software or an optional remote panel function via web server: manual function test (Start), output of test results, stand by (On/Off), maintained mode (On/Off), message from system configurations, system status and faults USB interface for uploading of the system configuration / download of the test results and software updates for the decentralised power system and the SicuroLED modules or SicuroLED inverter in the luminaires Charger: 27.2 V / 3.0 A 27.2 V / 5.0 A or 27.2 V / 10.0 A Battery: sealed Pb battery, model OGiV, with an expected service life of >10 years at an ambient temperature of 20 C Operation via colour 7 touchscreen with graphical and alphanumeric surface for input and output of all parameters and data, activated password protection and status LED for mains mode / battery mode / group fault. Combined cabinet design with separate electronic and battery part.

13 13 type Sicuro24-12 Sicuro24-24 Sicuro24-28 Sicuro24-56 order number (white) (white) (grey) (grey) order number (grey) (grey) battery capacity 12 Ah 24 Ah 28 Ah 56 Ah battery voltage 24 V 24 V 24 V 24 V battery current 1 h 6.5 A 12.0 A 12.0 A 12.0 A 3 h 2.8 A 5.6 A 7.0 A 12.0 A 8 h 1.1 A 2.3 A 3.1 A 6.16 A battery output 1 h 156 W 288 W 288 W 288 W 3 h 67.2 W W 170 W 288 W 8 h 26.4 W 55.2 W 74.4 W 148 W charging unit quantity voltage 27.2 V 27.2 V 27.2 V 27.2 V current 3 A 5 A 5 A 9 A luminaire circuit quantity 4 x 1 4 x 1 4 x 1 4 x 1 voltage 24 V = / 24 V = 24 V = / 24 V = 24 V = / 24 V = 24 V = / 24 V = current per circuit max. 3 A max. 3 A max. 3 A max. 3 A power per circuit max. 72 W max. 72 W max. 72 W max. 72 W LSSA circuit integrated web server integrated integrated integrated integrated modbus integrated integrated integrated integrated Ethernet interface integrated integrated integrated integrated USB interface integrated integrated integrated integrated RS486 interface integrated integrated integrated integrated mains monitoring module DS 1 optional optional optional optional UV / DS 3 UV LSSA module LSSA 8 mains monitoring / LSSA module LSSA 3+5 remote panel external modules max. 96 (optional) optional max. 96 (optional) optional max. 96 (optional) optional max. 96 (optional) optional Logica Visual monitoring software optional optional optional optional mounting wall wall wall wall combined cabinet sheet steel 1 sheet steel 1 sheet steel 2 sheet steel 2 Dimensions (LxWxH) 516x316x140 mm 644x316x140 mm 800x400x170 mm 800x400x170 mm degree of protection electronics IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 protection class I I I I supply 1 ~ N PE 50 Hz 1 ~ N PE 50 Hz 1 ~ N PE 50 Hz 1 ~ N PE 50 Hz 230 V +6 / -10 % 230 V +6 / -10 % 230 V +6 / -10 % 230 V +6 / -10 % ambient temperature electronics -5 C to +35 C -5 C to +35 C -5 C to +35 C -5 C to +35 C battery +20 C +20 C +20 C +20 C cable entry top / rear top / rear top top wire clamps mains 2.5 mm² 2.5 mm² 2.5 mm² 2.5 mm² battery 4.0 mm² 4.0 mm² 6.0 mm² 6.0 mm² luminaires 2 x 2.5 mm² 2 x 2.5 mm² 2 x 2.5 mm² 2 x 2.5 mm² 2.5 mm² 2.5 mm² 2.5 mm² 2.5 mm² 1 white (RAL 9003) or grey (RAL 7016), 2 grey ( RAL 7035)

14 14 Optional components for Sicuro24 Mains monitoring module DS 1 UV/DS 3 UV Module for monitoring mains supply of general lighting in the sub distribution boards. Activation of the control output during mains faults and mains failures U < 0,6 U Nenn for 0,5 s. Mains input: 1~ N 230 V / 50 Hz bzw. 3~ N 400 V / 50 Hz Control output: 2 changeover contacts, potential free V / 3 A Casing: plastic Dimensions (H x W x D): 90 x 52 x 58 mm Degree of protection: IP20 Mounting: distribution board installation (DIN rail ) Order code Type Description G31574 DS 1 UV mains monitoring module 1-phase G31026 DS 3 UV mains monitoring module 3-phase Mains monitoring and light switch query module LSSA 3+5 Module with 3 control inputs for monitoring the mains of general lighting or query of light switch of general lighting and 5 control inputs for query of light switch of general lighting. Function and logic of the control inputs and assignment to luminaire circuits or luminaires including free input of text designations is programmable to the decentralised power system. Control inputs for mains monitoring device: 3 or 0 Control signal: 1~ N 230 V / 50 Hz, invertible (U < 0,6 U Nenn for 0,5 s.) Control inputs for light switch query: 5 or 8 Control signal: 1~ N 230 V / 50 Hz, invertible Communication bus: RS 485 Casing: plastic Dimensions (H x W x D): 110 x 53 x 63 mm Degree of protection: IP20 Protection class: I Mounting: installation (DIN rail) Oder code Type Description G31585 LSSA 3+5 version for installation in distribution board Light switch query module LSSA 8 Module with 8 control inputs for query of light switch of general lighting. Function and logic of the control inputs and assignment to luminaire circuits or luminaires including free input of text designations is programmable to the decentralised power system. Casing: plastic Dimensions (H x W x D): 110 x 53 x 63 mm Degree of protection: IP20 Protection class: I Control inputs for light switch query: 8 Control signal: switching contact (potential free), invertible Communication bus: RS 485 Mounting: installation (DIN rail) Oder code Type Description G31586 LSSA 8 version for installation in distribution board

15 15 Remote Panel Remote panel for remote control of 63 Sicuro24 systems with the following functions: Test: function test (Start) per system or for all systems duration test (Start) per system or for all systems Control: maintained mode (On/Off) per system or for all systems stand by mode (On/Off) per system or for all systems Message: operating mode (mains/battery) per system stand by mode per system faults (group faults / battery / charge / luminaires / communication fault) per system tests of the last 2 years per system Switching input and signal output: 1 switch input, freely programmable, for switching of non-maintained mode (On/Off) / maintained mode switch (On/Off) / function test (Start) / duration test (Start) / nonmaintained mode switch (Off) all systems, deep discharge protection (acknowledge) for one or all systems, switch signal: contact, potential free 3 signal outputs, freely programmable, for message of status of charge / battery / circuit or luminaire / deep discharge / stand by mode / mains failure / battery mode / test mode for one or all systems, status signal: contact, potential free Communication bus: RS485 bus for communication via a intranet with the decentralised supplies Ethernet bus for communication via a intranet with the decentralised supplies Operation via colour 7 touchscreen with graphic and alphanumeric surface for input and output of all parameters and data, activated password protection, multi-language, and 3 status LED for display of mains mode / battery mode / group fault Mounting: wall mounting Wiring entry: from above / from the rear Casing: sheet steel, white (RAL 9003) or grey (RAL 7016) Degree of protection: IP20 Protection class: I Oder code Type Description Remote Panel Sicuro casing white Remote Panel Sicuro casing grey Logica Visual monitoring software See page 36 Signalling and switching module MSM-A See page 37 Signalling and switching module MSM-E See page 37

16 16 Advantages centralised supply NZBVA and NZBVE Supply of emergency luminaire in a building with several fire zones. System consisting of central station with battery, charger, control and monitoring and main distribution board and sub distribution board for maximum 120 luminaire circuits and maximum 30 sub-stations with sub distribution board for maximum 120 luminaire circuits. Central station with separate electronic and battery cabinets or combined cabinet with separate electronics and electronic part. Sub-stations in cabinet without or with function maintenance and compact version. Concept with separate components for charging, control and monitoring and luminaire circuits, individually replaceable. Batteries as sealed Pb battery with a service life > 10 years, alternatively also as sealed Pb battery > 15 years.

17 17 Automatic test equipment for carrying out function and service life tests and saving the test results. Optional central monitoring by a PC via an intranet and optional Logica Visual software or connection to a building management system via modbus. Test functions: manual function test (Start) output of test results Control functions: stand by mode (On/Off) maintained mode (On/Off) Message functions: assignment of the systems and circuits and the operating mode per circuit status and faults in online mode per system or circuit Luminaire circuits with 230V system voltage (mains and battery operation) with the following functions: operation of separate exit sign luminaires and emergency luminaires with integrated Alog or Sleb module for monitoring and control optionally automatic addressing with Alog modules or manual addressing with Sleb modules operation of combined general and emergency luminaires with separate Alog or Sleb module for monitoring and control separate Alog and Sleb modules with integrated control input for light switch query programmable maintained or non-maintained mode switch per light combinable maintained and non-maintained mode switch in one luminaire circuit selective switch (On/Off) per light in mains mode selective switch (On/Off) per light in emergency operation automatic test of all luminaire in one circuit with irregularity report per light Battery-Management-System Life Plus System for automatic messaging of faults of individual battery blocks and automatic control of charging of individual battery blocks at a uniform voltage level for extending the service life of battery systems with changes of the internal resistance of individual battery blocks.

18 18 Central supply NZBVA and NZBVE Central station (combined, floor standing (electronics + battery) or wall mounted cabinet (electronics) + floor standing cabinet (battery) Substation (floor standing, wall mounted cabinet without function maintenance or wall mounted cabinet with function maintenance) Compact substation (wall mounted cabinet) Exit sign luminaires with Sleb or Alog module Emergency luminaires with Sleb or Alog module Combined general and emergency luminaires with Sleb or Alog module Mains monitoring module (option) cable: min. 2 x 2 x 0.8 mm Light switch query module (option) cable: min. 2 x 2 x 0.8 mm + min. 1 x 2 x 1.5 mm

19 Signalling or switching module (option) - cable: min. 6 x 2 x 0.8 mm USB or Ethernet interface (option) for PC with Logica-Visual Software - cable: min. 2 x 2 x 0.8 mm / CAT-5 (Ethernet) RS485 bus for modbus RTU - cable: min. 2 x 2 x 0.8 mm USB or Ethernet interface (option) for OPC server with Logica-Visual Software - cable: USB or CAT5 230 V AC RS 485 bus 230 V DC Ethernet bus 230 V AC DC USB or Ethernet bus 24 V DC

20 20 Central station NZBVA-Z Control and monitoring with: automatic test equipment acc. to DIN EN for carrying out function and service life tests and saving the test results Luminaire circuits: 6, 14, 22 or 30 rack compartments for luminaire circuit assemblies output per circuit: max W, 690 W or 345 W (AC) voltage / current per circuit: 230 V / 6 A, 230 V / 3 A or 230 V / 1.5 A Description of the luminaire circuit assemblies see page Mains monitoring device: internal mains monitoring device control input for optional mains monitoring device Switching inputs and signalling outputs: 3 switch inputs, permanently programmed, for switching duration mode (On/Off), stand by mode (On/Off) and non-maintained mode switch, switch signal: contact, potential free 5 signalling outputs, fixed programmed, for message from group fault, stand by mode, power failure, battery mode and insulation fault, status signal: contact, potential free Control output: 1 control output for switching a fan in the battery compartment with time control, control signal: contact, potential free Interface: RS485 bus for communication with a building management system via modbus. Message from system configurations, system status and faults Charger: temperature controlled charging acc. to IV-characteristic with charge status dependent conversion of charging to maintaining charging charge current: 2 A (per charge assemblies) 6 rack compartments for charge assemblies Battery: sealed Pb battery, model OGiV, with an expected service life of >10 years at an ambient temperature of 20 C battery capacities from 12 Ah to 400 Ah Operation via display and buttons for input and output of all parameters and data, activated password protection and status LED for mains mode, battery mode, group fault. Floor standing cabinet design. Electronic cabinet with lockable viewing door and base. Pivoting frame for supporting assemblies in modular 19 modular system. Battery cabinet with lockable door and ventilation openings. Wiring fed from below. Type designation of the central station: NZBVA-Z/S 230/ / / /_ operating time (h) (1=1h / 3=3h / 8=8h) luminaire circuit assemblies rack compartments battery capacity (Ah) charge current (A)

21 Central station NZBVE-Z 21 Control and monitoring with: automatic test equipment acc. to DIN EN for carrying out function and service life tests and saving the test results Luminaire circuits: 6, 14, 22 or 30 rack compartments for luminaire circuit assemblies (floor standing cabinet) 6 or 14 rack compartments for luminaire circuit assemblies (wall mounted cabinet) output per circuit: max W, 690 W or 345 W (AC) voltage / current per circuit: 230 V / 6A, 230 V / 3 A or 230 V / 1.5 A Description of the luminaire circuit assemblies see page Mains monitoring device: internal mains monitoring device control input for optional mains monitoring device Switching inputs and signalling outputs: 3 switch inputs, permanently programmed, for switching duration mode (On/Off), stand by mode (On/Off) and non-maintained mode switch, switch signal: contact, potential free 5 signalling outputs, fixed programmed, for message from group fault, stand by mode, power failure, battery mode and insulation fault, status signal: contact, potential free Control output: 1 control output for switching a fan in the battery compartment with time control, control signal: contact, potential free Interface: RS485 bus for communication with a building management system via modbus. Message from system configurations, system status and faults. Charger: temperature controlled charging acc. to IV-characteristic with charge status dependent conversion of charging to maintaining charging. Charge current: 2 A (per charge assemblies) 6 rack compartments for charge assemblies Battery: sealed Pb battery, model OGiV, with an expected service life of >10 years at an ambient temperature of 20 C battery capacities from 12 Ah to 400 Ah Operation via display and buttons for input and output of all parameters and data, activated password protection and status LED for mains mode, battery mode, group fault. Wall mounted cabinet (electronics) and/or floor standing cabinet (electronics and battery) design. Electronic cabinet with lockable door and viewing window and optional base. Frame for supporting assemblies in modular 19 modular system. Battery cabinet with lockable door and ventilation openings and optional base. Wiring fed from above. Base (option): Oder code Type Description GZ5042 base for NZBVE height 100 mm Type designation of the central station: NZBVE-Z/_ 230/ / / /_ operating time (h) (1=1h / 3=3h / 8=8h) luminaire circuit assemblies rack compartments battery capacity (Ah) charge current (A) mounting (S=standing / W=wall)

22 22 Central station NZBVE-Z Kombi Control and monitoring with: automatic test equipment acc. to DIN EN for carrying out function and service life tests and saving the test results Luminaire circuits: 6 or 14 rack compartments for luminaire circuit assemblies output per circuit: max W, 690 W or 345 W (AC) voltage / current per circuit: 230 V / 6 A, 230 V / 3 A or 230 V / 1.5 A Description of the luminaire circuit assemblies see page Mains monitoring device: internal mains monitoring device control input for optional mains monitoring device Switching inputs and signalling outputs: 3 switch inputs, permanently programmed, for switching duration mode (On/Off), stand by mode (On/Off) and non-maintained mode switch, switch signal: contact, potential free 5 signalling outputs, fixed programmed, for message from group fault, stand by mode, power failure, battery mode and insulation fault, status signal: contact, potential free Control output: 1 control output for switching a fan in the battery compartment with time control, control signal: contact, potential free Interface: RS485 bus for communication with a building management system via modbus. Message from system configurations, system status and faults. Charger: temperature controlled charging acc. to IV-characteristic with charge status dependent conversion of charging to maintaining charging. Charge current: 2 A (per charge assemblies) 6 rack compartments for charge assemblies Battery: sealed Pb battery, model OGiV, with an expected service life of >10 years at an ambient temperature of 20 C battery capacities from 12 Ah to 110 Ah Operation via display and buttons for input and output of all parameters and data, activated password protection and status LED for mains mode, battery mode, group fault. Floor standing cabinet design with separate electronic and battery part and optional base. Electronic part with lockable door and viewing window. Frame for supporting assemblies in modular 19 modular system. Battery part with lockable door and ventilation openings. Wiring fed from above. Base (option): Oder code Type Description GZ5047 base for NZBVE height 100 mm Type designation of the central station: NZBVE-Z/K 230/ / / /_ operating time (h) (1=1h / 3=3h / 8=8h) luminaire circuit assemblies rack compartments battery capacity (Ah) charge current (A)

23 Sub-station NZBVA-U and NZBVE-U 23 Control and monitoring with: automatic test equipment acc. to DIN EN for carrying out function and service life tests and saving the test results Luminaire circuits: 6, 14, 22 or 30 rack compartments for luminaire circuit assemblies (floor standing cabinet) 6 or 14 rack compartments for luminaire circuit assemblies (wall mounted cabinet) output per circuit: max W, 690 W or 345 W (AC) voltage / current per circuit: 230 V / 6A, 230 V / 3 A or 230 V / 1.5 A Description of the luminaire circuit assemblies see page Mains monitoring device: internal mains monitoring device control input for optional mains monitoring device Switching inputs and signalling outputs: 3 switch inputs, permanently programmed, for switching duration mode (On/Off), stand by mode (On/Off) and non-maintained mode switch, switch signal: contact, potential free 5 signalling outputs, fixed programmed, for message from group fault, stand by mode, power failure, battery mode and insulation fault, status signal: contact, potential free NZBVA-U/S in floor standing cabinet: Floor standing cabinet design with lockable viewing door and base. Pivoting frame for supporting assemblies in modular 19 modular system. Wiring fed from below. NZBVE-U/S in floor standing cabinet: Floor standing cabinet design with lockable door and viewing window with optional base. Frame for supporting assemblies in modular 19 modular system. Wiring fed from above. NZBVE-U/W in wall mounted cabinet without functional integrity: Wall mounted cabinet design with lockable door and viewing window. Frame for supporting assemblies in modular 19 modular system. Wiring fed from above. NZBVE-U/W-30 in wall mounted cabinet with functional integrity of 30 minutes: Wall mounted cabinet design with lockable door without viewing window and integrated fan. Frame for supporting assemblies in modular 19 modular system. Wiring fed from above. Tested with electrical built-in components from a state material testing institute. Base (option): Oder code Type Description GZ5047 base for NZBVE height 100 mm Type designation of the sub-station: NZBVA-U / - _ NZBVE-U functional integrity 30 min. (-30) luminaire circuit assemblies rack compartments mounting (S = standing / A = wall)

24 24 Compact sub-station eak Compact sub-station with: Luminaire circuits: 2 or 4 luminaire circuits for maximum 20 luminaire per circuit combinable maintained and non-maintained mode switch in one circuit output per circuit: max. 400 W voltage / current per circuit: 230 V / 1.75 A Signal output: 1 signal output, fixed programmed, for signal from group fault, status signal: contact, potential free Indicators: 5 indicators for message of group fault, luminaire circuit fault, bus fault, mains mode and battery mode Operating time: operating time: 1 h, 3 h or 8 h (selectable) Distribution board casing design with lockable viewing door. Wiring fed from above. Oder code Type Description G31577 eak 2 2 luminaire circuits G31578 eak 4 4 luminaire circuits The number of compact eak sub-stations to be operated on one central station NZBVA-Z or NZBVE-Z or on a sub-station NZBVA-U or NZBVE-U is listed in the table. Note: The central control stations or sub-station may be dimensioned with maximum 14 slots for luminaire circuits. Type Number of compact sub-stations with combination of both types on a central or sub-station eak eak Junction box Junction box with a fire resistance of 30 min 1 and built in terminals and fuses. Material: building material with surface coating, non-flammable Color: grey (RAL7035) Dimensions (H x W x D): 350 x 350 x 128 mm Degree of protection: IP41 Protection class: II Mounting: wall or ceiling mounting (for ceiling mounting additional accessory required) Oder code Rising main Output cable Fuse G x 16 mm 3 x 16 mm² 2 x 6 A G x 50 mm 3 x 16 mm² 2 x 6 A G x 16 mm 3 x 16 mm² 2 x 10 A G x 50 mm 3 x 16 mm² 2 x 10 A 1 Versions with a fire resistance of 90 mins. available on request

25 Central supply NZBVE-Mini Central supply NZBVE-MINI with output limitation acc.to EN with: 25 Switching inputs and signalling outputs: automatic test equipment acc. to DIN EN for carrying out function and service life tests and saving the test results Luminaire circuits: 6 or 14 rack compartments for luminaire circuit assemblies output per circuit: max W, 690 W or 345 W (AC) voltage / current per circuit: 230 V / 6 A, 230 V / 3 A or 230 V / 1.5 A Description of the luminaire circuit assemblies see page Mains monitoring device: internal mains monitoring device control input for optional mains monitoring device Switching inputs and signalling outputs: 3 switch inputs, permanently programmed, for switching duration mode (On/Off), stand by mode (On/Off) and non-maintained mode switch, switch signal: contact, potential free 5 signalling outputs, fixed programmed, for message from group fault, stand by mode, power failure, battery mode and insulation fault, status signal: contact, potential free Control output: 1 control output for switching a fan in the battery compartment with time control, control signal: contact, potential free Interface: RS485 bus for communication with a building management system via modbus. Message from system configurations, system status and faults. Charger: temperature controlled charging acc. to IV-characteristic with charge status dependent conversion of charging to maintaining charging. Charge current: 2 A (per charge assemblies) 1 slot for charging assembly Battery: sealed Pb battery, model OGiV, with an expected service life of >10 years at an ambient temperature of 20 C battery capacities from 7 Ah to 12 Ah Operation via display and buttons for input and output of all parameters and data, activated password protection and status LED for mains mode, battery mode, group fault. Wall mounted cabinet design with separate electronic and battery part. Electronic part with lockable door and viewing window. Frame for supporting assemblies in modular 19 modular system. Battery part with lockable door and ventilation openings. Wiring fed from above. Type designation of the central station: NZBVE-Z/K 230/ / / /_ operating time (h) (1=1h / 3=3h / 8=8h) luminaire circuit assemblies rack compartments battery capacity (Ah) charge current (A)

26 26 Titel Type NZBVA-Z/S NZBVE-Z/S NZBVA-Z/W NZBVE-Z/K Battery capacity 12 to 400 Ah 12 to 200 Ah 12 to 200 Ah 12 to 110 Ah Battery voltage 216 V 216 V 216 V 216 V Battery current 1 h 280 A 280 A 280 A 78.3 A 3 h A A A 33.3 A 8 h 54.6 A max A 54.6 A max A Battery output 1 h W W W W 3 h W W W 7193 W 8 h W W W 3132 W Charging unit quantity max. 6 4 max. 6 4 max. 6 4 max. 4 4 voltage 246 V 246 V 246 V 246 V current 2 A 2 A 2 A 2 A Luminaire circuit quantity 30 x 1 / 30 x 2 / 30 x 4 30 x 1 / 30 x 2 / 30 x 4 14 x 1 / 14 x 2 / 14 x 4 14 x 1 / 14 x 2 / 14 x 4 voltage 230 V ~ / 216 V = current output 1 x 6 A / 2 x 3 A / 4 x 1.5 A 1 x 1380 W / 2 x 690 W / 4 x 345 W Sub-station outputs NZBV-U max. 2 4 max. 2 4 max. 2 4 max. 2 4 eak max. 2 4 max. 2 4 max. 2 4 max. 2 4 LSSA module / NÜ- / LSSA module internal modules max. 8 (optional) max. 8 (optional) max. 4 (optional) max. 2 (optional) Modbus integrated integrated integrated integrated Ethernet interface optional optional optional optional USB interface optional optional optional optional RS485 interface integrated integrated integrated integrated Integrated printer optional optional optional optional NÜ module DS 1 UV / DS 3 UV optional optional optional optional LSSA module external modules max. 16 (optional) max. 16 (optional) max. 16 (optional) max. 16 (optional) Logica Visual monitoring software optional optional optional optional Mounting floor standing floor standing wall floor standing Combined cabinet sheet steel. grey sheet steel. grey sheet steel. grey sheet steel. grey 2 battery cabinet 1 sheet steel. grey 2 sheet steel. grey 2 sheet steel. grey 2 Dimensions (LxWxH) 2000 x 800 x x 800 x x 800 x x 800 x 400 Degree of protection electronics IP54 IP54 IP54 IP54 battery IP21 IP21 IP21 IP21 Protection class I I I I Supply 3 ~ N PE 50 Hz 3 ~ N PE 50 Hz 3 ~ N PE 50 Hz 3 ~ N PE 50 Hz 400 V +6 / -10 % 400 V +6 / -10 % 400 V +6 / -10 % 400 V +6 / -10 % Ambient temperature electronics -5 C to +35 C -5 C to +35 C -5 C to +35 C -5 C to +35 C battery +20 C +20 C +20 C +20 C Cable entry below above above above Wire clamps mains 35 mm² 16 mm² 16 mm² 16 mm² battery dependent on the battery capacity / connected load: luminaires 2.5 mm² 2.5 mm² 2.5 mm² 2.5 mm² control input / output 1.5 mm² 1.5 mm² 1.5 mm² 1.5 mm² 1 Battery frame on request, 2 RAL 7035, 3 Supply through central station 4 dependent on the system configuration possibly even more

27 27 NZBVE-Mini NZBVA-U/S NZBVE-U/S NZBVE-U/W NZBVE-U/W-30 eak to 12 Ah V A A A W W W V A x 1 / 8 x 2 / 8 x 4 30 x 1 / 30 x 2 / 30 x 4 30 x 1 / 30 x 2 / 30 x 4 14 x 1 / 14 x 2 / 14 x 4 14 x 1 / 14 x 2 / 14 x 4 1 x 2 / 2 x V ~ / 216 V = 230 V ~ / 216 V = 1 x 6 A / 2 x 3 A / 4 x 1.5 A 2 x 1.75 A / 4 x 1.75 A 1 x 1380 W / 2 x 690 W / 4 x 345 W 2 x 400 W / 4 x 400 W max. 1 (optional) max. 8 (optional) max. 8 (optional) max. 2 (optional) max. 2 (optional) - integrated integrated integrated integrated integrated - optional optional optional optional optional - optional optional optional optional optional - integrated integrated integrated integrated integrated - integrated integrated integrated integrated integrated - optional optional optional optional optional - max. 16 (optional) max. 16 (optional) max. 16 (optional) max. 16 (optional) max. 16 (optional) - - optional optional optional optional optional - wall floor standing floor standing wall wall wall sheet steel. grey sheet steel. grey 2 sheet steel. grey 2 sheet steel. grey 2 fire protection plate polystyrene. grey x 600 x x 800 x x 800 x x 600 x x 600 x x 650 x x 295 x x 295 x 130 IP21 IP54 IP54 IP54 IP54 IP65 IP I I I I I II 3 ~ N PE 50 Hz 230 V ~ (main) V ~ (main) V ~ (main) V ~ (main) V ~ (main) V +6 / -10 % 216 V = (battery) V = (battery) V = (battery) V = (battery) V = (battery) 3-5 C to +35 C -5 C to +35 C -5 C to +35 C -5 C to +35 C -5 C to +35 C -5 C to +35 C +20 C above below above above above above / below 16 mm² 35 mm² 16 mm² 16 mm² 16 mm² 16 mm² dependent on the battery capacity / connected load: 16 mm² 2.5 mm² 2.5 mm² 2.5 mm² 2.5 mm² 2.5 mm² 2.5 mm² 1.5 mm² 1.5 mm² 1.5 mm² 1.5 mm² 1.5 mm² 1.5 mm²

28 28 Tecnical data of the batteries: Model: sealed Pb battery with basket electrode and AGM separator conforming to DIN EN and EUROBAT Service life expectancy: >16 years at an ambient temperature of 20 C (data exclusive of ageing reserve) Battery capacity (Ah) Battery voltage (V) Battery current (A) h Connected load (W) Battery current (A) h Connected load (W) Battery current (A) h Connected load (W) Battery capacity (Ah) Battery voltage (V) Battery current (A) h Connected load (W) Battery current (A) h Connected load (W) Battery current (A) h Connected load (W) Model: sealed Pb battery with shielded electrodes conforming to DIN EN and EUROBAT Service life expectancy: >16 years at an ambient temperature of 20 C (data exclusive of ageing reserve) Battery capacity (Ah) Battery voltage (V) Connected load (W) 1 h Connected load (W) 3 h Connected load (W) 8 h

29 Battery management system for NZBVA and NZBVE 29 Battery management system Life Plus System for automatic messaging of faults of individual battery blocks and automatic control of charging of individual battery blocks at a uniform voltage level for extending the service life of battery systems with changes of the internal resistance of individual battery blocks. Functions: automatic monitoring of the individual voltage of each battery block automatic monitoring of the total voltage of all battery blocks automatic equalisation charge for differing individual voltage from battery blocks display of individual voltages of the battery blocks, total voltage of the battery blocks, voltage of one battery block < 10 V, voltage of one battery block > 18 V, charge, equalisation charge Life Plus controller with 9 Life-Plus modules. Connection of the controller and the modules via a bus with automatic addressing of the modules. Controller Mounting: installation in the central station (profile rail) Casing: polycarbonate Dimensions (H x W x D): 90 x 160 x 75 mm Degree of protection: IP 20 Protection class: II Module Casing: plastic Dimensions (H x W x D): 152 x 32 x 24 mm Degree of protection: IP 20 Protection class: I Oder code 17227K Description battery Life Plus

30 30 Luminaire circuit assemblies for NZBVA and NZBVE Luminaire circuit assembly AK 1 x 32 EÜ Assembly with 1 circuit for 1 x 20 (32) luminaires with: LED + electronic operating unit 1 discharge lamps + electronic operating unit 1 incandescent lamps combined operation of individual luminaires in duration and non-maintained mode switch in one circuit monitoring of individual luminaires in one circuit with irregularity report per light with additional monitoring and switching module in the luminaires switching of individual luminaires in one circuit from maintained in stand by via a light switch position query module or a monitoring and switching module Connected load: 1 x 1380 W Switch on output: 1 x W (max. output for 1 ms) Fuse: 2 x 10 AT / 500 V Design: 19 plug in (1 slot) Order code G32754-SL-P Type AK 1 x 32 EÜ Luminaire circuit assembly AK 2 x 32 EÜ Assembly with 1 circuit for 2 x 20 (32) luminaires with: LED + electronic operating unit 1 discharge lamps + electronic operating unit 1 incandescent lamps combined operation of individual luminaires in duration and non-maintained mode switch in one circuit monitoring of individual luminaires in one circuit with irregularity report per light with additional monitoring and switching module in the luminaires switching of individual luminaires in one circuit from maintained in stand by via a light switch position query module or a monitoring and switching module Connected load: 2 x 690 W Switch on output: 2 x W (max. output for 1 ms) Fuse: 4 x 5 AT / 500 V Design: 19 plug in (1 slot) Order code G32818-SL-P Type AK 2 x 32 EÜ Luminaire circuit assembly AK 4 x 32 EÜ Assembly with 1 circuit for 4 x 20 (32) luminaires with: LED + electronic operating unit 1 discharge lamps + electronic operating unit 1 incandescent lamps combined operation of individual luminaires in duration and non-maintained mode switch in one circuit monitoring of individual luminaires in one circuit with irregularity report per light with additional monitoring and switching module in the luminaires switching of individual luminaires in one circuit from maintained in stand by via a light switch position query module or a monitoring and switching module Connected load: 4 x 345 W Switch on output: 4 x W (max. output for 1 ms) Fuse: 8 x 2.5 AT / 500 V Design: 19 plug in (1 slot) Order code G32824-SL-P Type AK 4 x 32 EÜ 1 Operating unit must be suitable for use in emergency luminaire acc. to EN 50172

31 31 Luminaire circuit assembly AK 1 x 32 SÜ Assembly with 1 circuit for 1 x 20 (32) luminaires with: LED + electronic operating unit 1 discharge lamps + electronic operating unit 1 incandescent lamps operation of all luminaires in maintained or non-maintained mode switch in one circuit monitoring of all luminaires in one circuit with irregularity report per circuit without additional monitoring and switching module in the luminaires switching of all luminaires in one circuit from maintained in stand by via a light switch position query module Connected load: 1 x 1380 W Switch on output: 1 x W (max. output for 1 ms) Fuse: 2 x 10 AT / 500V Design: 19 plug in (1 slot) Order code G32797S-P Type AK 1 x 32 SÜ Luminaire circuit assembly AK 2 x 32 SÜ Assembly with 1 circuit for 2x 20 (32) luminaires with: LED + electronic operating unit 1 discharge lamps + electronic operating unit 1 incandescent lamps operation of all luminaires in maintained or non-maintained mode switch in one circuit monitoring of all luminaires in one circuit with irregularity report per circuit without additional monitoring and switching module in the luminaires switching of all luminaires in one circuit from maintained in stand by via a light switch position query module Connected load: 2 x 690 W Switch on output: 2 x W (max. output for 1 ms) Fuse: 4 x 5 AT / 500 V Design: 19 plug in (1 slot) Order code G32815S-P Type AK 2 x 32 SÜ Luminaire circuit assembly AK 4 x 32 SÜ Assembly with 1 circuit for 4 x 20 (32) luminaires with: LED + electronic operating unit 1 discharge lamps + electronic operating unit 1 incandescent lamps operation of all luminaires in maintained or non-maintained mode switch in one circuit monitoring of all luminaires in one circuit with irregularity report per circuit without additional monitoring and switching module in the luminaires switching of all luminaires in one circuit from maintained in stand by via a light switch position query module Connected load: 4 x 345 W Switch on output: 4 x W (max. output for 1 ms) Fuse: 8 x 2.5 AT / 500 V Design: 19 plug in (1 slot) Order code Type G32820S-P AK 4 x 32 SÜ 1 Operating unit must be suitable for use in emergency luminaire acc. to EN 50172

32 32 Monitoring and switching modules for NZBVA and NZBVE Monitoring and switching module Module: monitoring of luminaires with selective irregularity report combined operation of luminaires in non-maintained mode switch and maintained mode switch, switchable via internal LSSA switching input or a light switch query module Light output: 4 W W Mains voltage: 80 V V / 50 Hz Battery voltage: 90 V V Mounting: light installation Casing: plastic Dimensions (L x W x H): 152 x 32 x 24 mm Degree of protection: IP20 Protection class: I Oder code Type Description G31432 Alog automatic addressing G31431 Sleb manual addressing E25651 additional casing for light attachment Monitoring and switching module DALIlightmanagement Module with the same functions as the monitoring and switching module, however with DALI control input and control output to interruption of the DALI control signal with partial mains failures and setting of the lumen factor (10 % to 100 %) in DC operation. Light output: 4 W W Mains voltage: 195 V V / 50 Hz Battery voltage: 176 V V Mounting: light installation Casing: metal Dimensions (L x W x H): 236 x 45 x 31mm Degree of protection: IP20 Protection class: I Oder code Type Description G31358 Alog-DALI automatic addressing G31362 Sleb-DALI manual addressing

33 Optional system components for NZBVA and NZBVE 33 Mains monitoring module DS 1 UV/DS 3 UV Module for monitoring mains supply of general luminaires in the sub distribution boards. Activation of the control output during mains faults and mains failures with U < 0,6 U Nenn for 0,5 s. Mains input: 1~ N 230 V / 50 Hz bzw. 3~ N 400 V / 50 Hz Control output: 2 changeover contacts, potential free V / 3 A Casing: plastic Dimensions (H x W x D): 90 x 52 x 58 mm Degree of protection: IP20 Protection class: II Mounting: distribution board installation (DIN rail) Order code. Type Description G31574 DS 1 UV mains monitoring module, 1-phase G31026 DS 3 UV mains monitoring module 3-phase Light switch query module LSSA 230 Module with 8 control inputs for query of light switch of general luminaires logic of the control inputs and assignment to luminaire circuits or luminaires, freely programmable. Connection to the central power system with installation in distribution board through 4-wire cable for bus and supply. Control inputs for light switch query: 8 Control signal: 230 V AC, invertible Communication bus: RS 485 Casing: plastic Dimensions (H x W x D): 95 x 94 x 43 mm (LSSA 230) Dimensions (H x W x D): 90 x 88 x 58 mm (LSSA 230 UV) Degree of protection: IP20 Protection class: II Mounting: installation (DIN rail) Order code. Type Description G31204 LSSA 230 version for installation in central or sub-station G31575 LSSA 230 UV version for installation in distribution board Light switch query module LSSA 24 Module with 8 control inputs for query of light switch of general luminaires logic of the control inputs and assignment to luminaire circuits or luminaires, freely programmable. Connection to the central power system with installation in distribution board through 4-wire cable for bus and supply. Control inputs for light switch query: 8 Control signal: switching contact (potential free), invertible Communication bus: RS 485 Casing: plastic Dimensions (H x W x D): 95 x 94 x 43 mm (LSSA 24) Dimensions (H x W x D): 90 x 88 x 58 mm (LSSA 24 UV) Degree of protection: IP20 Protection class: II Mounting: installation (DIN rail) Order code. Type Description G31207 LSSA 24 version for installation in central or sub-station G31573 LSSA 24 UV version for installation in distribution board

34 34 Optional components for NZBVA and NZBVE Signalling module Module with 8 signal outputs, permanently programmed, for signal from group fault, stand by mode, mains mode, battery mode and insulation fault. Status signal: contact, potential free with fixed time delay Casing: plastic Dimensions (H x W x D): 95 x 94 x 43 mm Degree of protection: IP20 Protection class: I Oder code G31023 Description signalling module Switching module Module with 8 switching inputs for switching of maintained mode switching (On/Off), stand by mode (On/Off) and non-maintained mode switching (Off), function test (Start), duration test (Start) and deep discharge (acknowledge) and maintained mode (Reset). Switching signal: contact, potential free Casing: plastic Dimensions (H x W x D): 95 x 94 x 43 mm Degree of protection: IP20 Protection class: I Oder code G31171 Description switching module OPC server for Logica Visual Server and software for monitoring and control of emergency luminaire with central supply. Message: current status in online mode (stand by mode / operating mode / faults/ tests) per light faults in online mode (lamp / communication fault) per light tests of the last 2 years per system Version for Windows XP (32/64 Bit), Windows VISTA (32/64 Bit), Windows 7 (32/64 Bit), Windows 8 (32/64 Bit) Oder code SWB16312 Description OPC-Server for Logica Visual

35 35 RS485-RS232 Ethernet interface Module for indirect connection to a central supply to a PC with Logica Visual software via a network. Casing: plastic Dimensions (L x W x D): 35.5 x 17.1 x 7.6 mm Degree of protection: IP20 Protection class: I Oder code G31209 Description RS485-RS232 / Ethernet interface RS485/USB interface Module for communication between a central supply and a PC with Logica Visual software (option) via USB. Casing: metal Dimensions (L x W x D): 151 x 75 x 26 mm Degree of protection: IP20 Protection class: III Mounting: profile rail Oder code FB16319 Description RS485 USB interface Integrated printer Printer for connection to a central supply. Printout of fault messages and test results. Paper type: thermal paper. Degree of protection: IP20 Protection class: I Design: 19 plug in (2 rack compartments) Oder code M10053A H14146 Description integrated printer printer paper (replacement)

36 36 Optional components for Sicuro24, NZBVA and NZBVE Monitoring and control software Logica Visual Software for central monitoring and control of complex emergency luminaire with single battery supply, decentralised or centralised supply. Functions: Monitoring: automatic or manual execution of a function test automatic or manual execution of a operating duration test Control: manual switching (On/Off) of the maintained mode in mains mode per system (decentralised and centralised supply) Message: current status in online mode (stand by mode / operating mode / faults / tests) in graphs and numerical format per luminaire (decentralised and centralised supply) faults in online mode (lamp / communication fault) per luminaire (decentralised and centralised supply) tests of the last 2 years per system (decentralised and centralised supply) Programming: import of floor plans as DXF/DWG file text and graph assignment of all systems, circuits and luminaires or luminaires, supply devices and supply modules system parameters per system test parameters per system operating mode per circuit or luminaire (decentralised and centralised supply) switching per circuit or luminaire (decentralised and centralised supply) test parameters (date, time, duration, cycle) per system. free assignment of circuits and luminaires to monitoring and control units per system (decentralised and centralised supply) 2 programmable time control scenes with 7 x 5 switching commands (maintained mode) per system (centralised supply) 3 programmable time control scenes with 7 x 5 switching commands (maintained mode) per system (decentralised supply) Version for Windows XP (32/64 Bit), Windows VISTA (32/64 Bit), Windows 7 (32/64 Bit), Windows 8 (32/64 Bit) and Windows 10 (32/64 Bit). Oder code SWB16311 Description Logica Visual

37 37 Signalling and switching module MSM-A Signal (optical) of: stand by mode battery mode group fault Switching (key switch) of: maintained mode Casing: plastic Dimensions (H x W x D): 160 x 80 x 60 mm Degree of protection: IP65 Protection class: III Mounting: wall mounting Oder code Description G31015 MSM-A signalling and switching module Signalling and switching module MSM-E Signal (optical) of: stand by mode battery mode group fault Switching (key switch) of: maintained mode Casing: plastic / metal Dimensions (H x W x D): 86 x 86 x 53 mm Degree of protection: IP20 Protection class: III Mounting: wall mounting Oder code Description G31045 MSM-E signalling and switching module Signalling and switching module MSM-T Signal (optical) of: stand by mode battery mode group fault Switching (key switch) of: maintained mode stand by mode stand by mode reset Casing: plastic Dimensions (H x W x D): 185 x 245 x 107 mm Degree of protection: IP65 Protection class: II Mounting: wall mounting Oder code Description G31044 MSM-T signalling and switching module

SicuroLED-G - advantages

SicuroLED-G - advantages 6 SicuroLED-G - advantages For emergency lightings with external supply escape routes, areas with particular panic hazard, workplaces with particular people hazard and safety devices can be illuminated

More information

Emergency Lighting. Catalogue. Central Power systems

Emergency Lighting. Catalogue. Central Power systems Emergency Lighting Catalogue Central Power systems Beghelli-Präzisa GmbH is constantly developing and improving the product range. All descriptions, illustrations, drawings and specifications present only

More information

Emergency. Lighting KATALOG 2015 CENTRAL POWER SYSTEMS

Emergency. Lighting KATALOG 2015 CENTRAL POWER SYSTEMS Emergency KATALOG 2015 Lighting CENTRAL POWER SYSTEMS Gruppo Beghelli Light is safety - Since more than 3 decades the Gruppo Beghelli is a competent partner of lighting designers, qualified electrical

More information

LPS Central supply system for emergency luminaires 24 V for separate fire areas

LPS Central supply system for emergency luminaires 24 V for separate fire areas RUSIC 24 LPS Central supply system for emergency luminaires 24 V for separate fire areas Wiring system with all advantages of safety extra-low voltage (SELV) Energy-optimised by use of LED luminaires with

More information

RUSIC 24. LPS Central supply system for emergency luminaires 24 V for separate fire areas

RUSIC 24. LPS Central supply system for emergency luminaires 24 V for separate fire areas RUSIC 24 LPS Central supply system for emergency luminaires 24 V for separate fire areas Wiring system with all advantages of safety extra-low voltage (SELV) Energy-optimised by use of LED luminaires with

More information

LP-STAR. Compact emergency lighting power supply with STAR technology Eaton, All Rights Reserved.

LP-STAR. Compact emergency lighting power supply with STAR technology Eaton, All Rights Reserved. LP-STAR Compact emergency lighting power supply with STAR technology Central overall fire protection section installation Advantages: One distributor for all emergency light circuits Central distributor

More information

Introduction Selfcontained luminaries

Introduction Selfcontained luminaries Range of products Central Introduction Selfcontained luminaries (Battery pack inside) Advantages of CBS Integrated test book for 2 years Using the general lighting as emergency luminaires Designed lifetime

More information

SPS CENTRAL BATTERY SYSTEMS

SPS CENTRAL BATTERY SYSTEMS SYSTEM OVERVIEW 2 OFFLINE TECHNOLOGY IF NEEDED 4 CONTROL UNIT 5 COMPARISON OF SPS SYSTEMS 8 ACCESSORIES 11 SYSTEM OVERVIEW The Central Battery System SPS provides emergency power supply when the mains

More information

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.

More information

AC5160 SiPass integrated controller kit

AC5160 SiPass integrated controller kit AC5160 SiPass integrated controller kit SiPass integrated Wall housing with pre-assembled basic SiPass integrated components Equipped with one ACC (AC5100), two dual reader interfaces (ADD5100) and one

More information

Lighting Controls and Connectivity DALI sensors. MSensor G3 SFI 30 PIR 10DPI WH Multi-sensor

Lighting Controls and Connectivity DALI sensors. MSensor G3 SFI 30 PIR 10DPI WH Multi-sensor MSensor G3 SFI 30 PIR 10DPI WH Multi-sensor Product description Sensor developed to work with the latest DALI specification Monitoring of ambient light and motion detection Remote control interface allowing

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling. 360b/01

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling. 360b/01 Electronics Ltd Presenting Power, Intelligence... with a sense of feeling 360b/01 Plug in slots K772 16 Channel I/O Board K791 8 Way Relay Board K792 8 Way Conventional Zone Board K793 4 Way Sounder Board

More information

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER On-line UPS-system according to DIN EN 62040-3 (VFI-SS-111) with sinus soidal output voltage in each operation mode, RS232 interface and Shutdown-Software for Windows NT/2000/XP/2003/Vista, Novell and

More information

Content. List of emergency lighting 4 Emergency luminaires 6 Index 22

Content. List of emergency lighting 4 Emergency luminaires 6 Index 22 Content List of emergency lighting 4 Emergency luminaires 6 Index 22 This catalogue includes selected standard emergency lighting and components. For the complete range of Beghelli emergency lighting and

More information

Central Battery System ZB-S Eaton, All Rights Reserved.

Central Battery System ZB-S Eaton, All Rights Reserved. Central Battery System ZB-S Central Battery System ZB-S Agenda New charging technology System Configuration Internal Modules External Modules Battery Management System PC Software CG Vision Date, Venue

More information

HandRail 930XX LED Safety Luminaires for Escape Route Lighting

HandRail 930XX LED Safety Luminaires for Escape Route Lighting When confronted with emergency lighting applications where a ceiling or post top mounting is not possible, Eaton offer a broad innovative low power hand hail mounted emergency luminaire. The hand rail

More information

Selectronic accessories to support the SelectSun 3 phase grid-tie inverter range

Selectronic accessories to support the SelectSun 3 phase grid-tie inverter range Selectronic accessories to support the SelectSun 3 phase grid-tie inverter range Our all new SelectSun range of 3 phase solar inverters are equally at home with or without batteries. Available in 20kW

More information

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Battery charger. Power plants. Substations. Rail and infrastructure. Industry. Thyristor controlled with controller GMU

Battery charger. Power plants. Substations. Rail and infrastructure. Industry. Thyristor controlled with controller GMU Battery charger Thyristor controlled with controller GMU Power plants Substations Rail and infrastructure Industry Battery charger Thyristor controlled with controller GMU Battery back-up DC-power supply

More information

ISOMETER isoev425 with coupling device AGH420

ISOMETER isoev425 with coupling device AGH420 with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary datasheet isoev425_d00126_02_d_xxde/09.2015 with coupling device

More information

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005 Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program

More information

Plexo IP 55/IP 66. Makes your day, rain or shine PLEXO / WEATHERPROOF PRODUCT GUIDE. For reference only.

Plexo IP 55/IP 66. Makes your day, rain or shine PLEXO / WEATHERPROOF PRODUCT GUIDE. For reference only. Plexo IP 55/IP 66 Makes your day, rain or shine PLEXO / WEATHERPROOF PRODUCT GUIDE www.legrand.com.sg Plexo IP 55 Ingenious features for easy installation >> Time saving guaranteed: no cut-out Uncut pierceable

More information

LP-STAR emergency lighting power supply in a compact design Installation example

LP-STAR emergency lighting power supply in a compact design Installation example Installation example LP- STAR Ethernet LP- STAR Ethernet Ethernet LP- STAR Ethernet Example connection to the central visualisation system CG Vision Building 2 Ethernet CG-S bus Building 1 IP router Central

More information

OT EASY 60 II. LED control unit Operating instructions

OT EASY 60 II. LED control unit Operating instructions II LED control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Intended use 4 Description... 5 Function and application 5 Function 5 Important definitions

More information

LP-STAR emergency lighting power supply in a compact design Installation example

LP-STAR emergency lighting power supply in a compact design Installation example Installation example LP- STAR Ethernet LP- STAR Ethernet Ethernet LP- STAR Ethernet Example connection to the central visualisation system CG Vision Building 2 Ethernet CG-S bus Building 1 IP router Central

More information

Gas Controller System DGC-06

Gas Controller System DGC-06 Page 1 May 2016 Measuring, warning and controlling device series for toxic, combustible and refrigerant gases and vapours. The gas controller series DGC-06 is designed in accordance with the standard EN

More information

LED Lighting Catalogue 2016 / 2017

LED Lighting Catalogue 2016 / 2017 LED Lighting Catalogue 2016 / 2017 Upgrade to LED Lighting with Sharp LED Lighting Turn the many benefits of LED lighting to your advantage LED technology is said to be the most important invention in

More information

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads Data sheet 709061 Page 1/21 JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads The JUMO TYA 201 represents a consistent further development of the JUMO power controller

More information

MULTICHANNEL DATA RECORDERS

MULTICHANNEL DATA RECORDERS MULTICHANNEL DATA RECORDERS Introduction ma + V / mv RTD + - universal inputs + - TC universal inputs: RTD + TC or U + I (SRD-99) fixed inputs: RTD, TC, U, I (SRD-N16) 2 relay outputs memory up to 3 000

More information

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva GE Critical Power Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS 3 5 6 8 10 kva GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91

More information

InForm Superstructures

InForm Superstructures Advantages InForm racks are fitted between the vertical profiles and thus ensure a generous amount of open working table surface. Devices are installed directly in the 3HU and 6HU racks, additional devices

More information

Lighting Controls and Connectivity DALI sensors. MSensor G3 SFI 30 PIR 5DPI WH/BK Multi-sensor

Lighting Controls and Connectivity DALI sensors. MSensor G3 SFI 30 PIR 5DPI WH/BK Multi-sensor MSensor G3 SFI 3 PIR 5DPI WH/BK Multi-sensor Product description Sensor developed to work with the latest DALI specification Monitoring of ambient light and motion detection Remote control interface allowing

More information

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional

More information

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

Energy meters Single phase electrical energy meters WM1-6 / WM1M6 Energy meters Single phase electrical energy meters WM1-6 / WM1M6 o Single phase direct connected DIN-rail mounting meter o Class 1 for active energy according to EN 62053-21 and B according to EN 50470-3

More information

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001 SK 0012 B 98 The control unit is a DIN rail mounted device for insertion in the distribution board. It is used to control digitally dimmable electronic ballast devices or transformers via the EIB. In a

More information

CPS kVA TRIFASE EN50171

CPS kVA TRIFASE EN50171 PRINCIPLES OF WORKING The loads can be divided into two types: 1) Users always powered (SA). the users are always fed both in the presence and absence of the mains. 2) Users powered emergency service only

More information

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA The SR series on line double conversion UPS with full time Digital Signal Processor control technology is the perfect solution for mission critical users who demand high reliability, availability and performance

More information

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected

More information

InForm Superstructures

InForm Superstructures Advantages InForm racks are fitted between the vertical profiles and thus ensure a generous amount of open working table surface. Devices are installed directly in the 3HU and 6HU racks, additional devices

More information

Lighting control for commercial buildings

Lighting control for commercial buildings [ INTELLIGENT SOLUTIONS ] Products and systems Lighting control for commercial buildings For management of different functions in a simultaneous and integrated way, via a BUS line Cost saving thanks to

More information

Accessories for Sunny Central COMMUNICATION CABINET (COM-C)

Accessories for Sunny Central COMMUNICATION CABINET (COM-C) Accessories for Sunny Central COMMUNICATION CABINET (COM-C) Technical Description COM-C-TEN084210 98-4011910 Version 1.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Product Details...................................

More information

Intelligent DC UPS Module

Intelligent DC UPS Module Intelligent DC UPS Module 2V/9~36V DC Input, 2V DC Output Uninterruptible Power Supply Module with Diagnostics Features Model Name AUPS-A0 / AUPS-A20 Input Power AUPS-B0 (2V) AUPS-A20 (9~36V) AUPS-B20

More information

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP SIMBOX 63 /4 Introduction /5 Flush mounting distribution boards /6 Hollow-wall distribution boards /7 Surface mounting distribution boards /7 Hood-type

More information

Lighting Controls and Connectivity scenecom. scenecom L, XL, XL EM and XL EM Bac scenecom Controller

Lighting Controls and Connectivity scenecom. scenecom L, XL, XL EM and XL EM Bac scenecom Controller L, XL, XL EM and XL EM Bac Controller Product description Independent lighting control for up to 192 DALI control gears on 3 DALI lines Simple setup via WEB interface Cross DALI line control Freel programmable

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

AC5160 Controller. Fire & Security Products. SiPass integrated

AC5160 Controller. Fire & Security Products. SiPass integrated AC5160 Controller SiPass integrated Wall housing with pre-assembled SiPass basic components Equipped with one ACC, two DRI and one power supply Extendable with additional components The AC5160 is a wall

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from POE084824B v.1.1 PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. EN* Edition: 7 from 15.11.2017 Supersedes the edition: 6 from 22.11.2016 GREEN POWER CCTV PoE PSU features: DC 54V uninterruptible

More information

MULTICHANNEL DATA RECORDERS

MULTICHANNEL DATA RECORDERS MULTICHANNEL DATA RECORDERS Introduction ma + V / mv RTD + - universal inputs + - TC universal inputs: RTD + TC or U + I (SRD-99) fixed inputs: RTD, TC, U, I (SRD-N16) 2 relay outputs memory up to 3 000

More information

AIAS. Technical description

AIAS. Technical description Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains AIAS - and Efficient Heating Demand Products Controlled Tunnel Ventilation Fans 1 / 4 AIAS Technical description 2 / 9 AIAS -

More information

How to choose the correct Mount Kelvin central unit

How to choose the correct Mount Kelvin central unit Installation guide Outside world Property Wirepas mesh Mount Kelvin app Internet connection Ethernet DALI 3rd party integrations Mount Kelvin cloud Mount Kelvin central unit Voice control EnOcean wireless

More information

JUMO TYA 202 SCR Power Controller in a three-phase economy circuit For the continous control of ohmic-inductive loads

JUMO TYA 202 SCR Power Controller in a three-phase economy circuit For the continous control of ohmic-inductive loads Data sheet 709062 Page 1/17 JUMO TYA 202 SCR Power Controller in a three-phase economy circuit For the continous control of ohmic-inductive loads The JUMO TYA 202 represents a consistent further development

More information

Mureva Assembly surface mounted wiring devices

Mureva Assembly surface mounted wiring devices Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label using the legended

More information

1. Introduction External description Front and Rear Panel The LCD screen Alarm Conditions...6

1. Introduction External description Front and Rear Panel The LCD screen Alarm Conditions...6 Product Description LanPro 31 Contents: 1. Introduction...2 2. Functional explanation...2 2.1 Principles of Operation...2 2.2 Normal Conditions...3 2.3 Mains Failure...3 2.4 Bypass operation...4 3. External

More information

Data sheet. Function description. Benefits

Data sheet. Function description. Benefits Function description To permit direct communication with the Philips SR interface, we offer two of our best and most innovative sensors: the ED PIR sensor with its patented multi-segment sensor lens and

More information

All safety luminaires are important. They help protect the life and health of people.

All safety luminaires are important. They help protect the life and health of people. All safety luminaires are important. They help protect the life and health of people. Emergency lighting must be fully functional to provide protection in case of failure of the general lighting. Even

More information

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22) .3 Ex-Linear light fittings for fluorescent lamps ellk 9 18 W 58 W / ellm 9 18 W 36 W (Zone 1,, 1, ) The classic lighting solution in hazardous areas The ellk 9 linear luminaire series for fluorescent

More information

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Keor HPE UPS THREE-PHASE UPS from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world

More information

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial

More information

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS (WITH CAPACITOR CHARGER BOARD A3517-02) The process depends on Generator and System configuration. This document applies to installation of Capacitors

More information

Mounting and Operating Instructions Central Battery System ZB-S with STAR-Technology

Mounting and Operating Instructions Central Battery System ZB-S with STAR-Technology CEAG ZB-S Mounting and Operating Instructions Central Battery System ZB-S with STAR-Technology Target group, part 1: Qualified electrician acc. to DIN VDE 0105, part1 Target group. part 2: Electrical instucted

More information

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) COMPACT LED DRIVERS PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) 186762, 186763 Typical Applications Built-in in compact luminaires Shop lighting Downlights PrimeLine DALI dimmable & Selectable

More information

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA Patented quality product (Immersion sensor patent no. DE 10 2012 017 500.0) Calibratable temperature measuring transducer THERMASGARD with eight switchable measuring ranges, continuous linear output, enclosure

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

ISOMETER isoev425/isoev425hc with coupling device AGH420

ISOMETER isoev425/isoev425hc with coupling device AGH420 with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles isoev425_d00126_04_d_xxen/06.2018 with coupling device AGH420 Insulation monitoring

More information

Plexo IP 55/IP 66 Makes your day, rain or shine

Plexo IP 55/IP 66 Makes your day, rain or shine Plexo IP 55/IP 66 Makes your day, rain or shine PLEXO / WEATHERPROOF WIRING DEVICES www.legrand.com.sg Plexo IP 55 Ingenious features for easy installation >> Time saving guaranteed: no cut-out Uncut pierceable

More information

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions DALI gateway Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please

More information

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication X X testregistrierung Control system Type Central BMS interface DCP-FSL II-Stand-alone Pressure independent control valve Straight-way valve Modular, stand-alone room control system, specially for decentralised

More information

Cabinets and accessories for power supply

Cabinets and accessories for power supply Cabinets and accessories for power supply Version 2.0 1 As a supplier of broadband communication technology braun telecom has stood for competence and continuity for more than 30 years. With our long experience

More information

24/48V Battery Bank Ah High Cycling Long Life

24/48V Battery Bank Ah High Cycling Long Life Outdoor Power Cabinets, 48V DC Free Cooled with Combined Air-Con. PreFactory assembled with 19 inch Power sub rack, 2 or 4 battery Shelf s, 3U DCAC Panel combined with rectifiers 2U or 4U Power Module

More information

CEAG HandRail 930XX LED. Hand rail mounted Luminaire for all applications

CEAG HandRail 930XX LED. Hand rail mounted Luminaire for all applications CEAG HandRail 930XX LED Hand rail mounted Luminaire for all applications Safety luminaire When confronted with emergency lighting applications where a ceiling or post top mounting is not possible, Eaton

More information

Blue e+ chillers with the principle

Blue e+ chillers with the principle Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide

More information

Smart Monitoring System compact, secure, efficient

Smart Monitoring System compact, secure, efficient Smart Monitoring System compact, secure, efficient Transparency for more efficiency Continuously record and monitor the energy consumption of plant and machinery Visualise data on a display or through

More information

Accessories Fieldbus Box

Accessories Fieldbus Box Power cables, sensor cables, connection cables and further accessories see the EtherCAT Box chapter from page 514 Pre-assembled cables for fieldbus components include a wide range of cable assemblies.

More information

IP65 Rated Emergency LED Luminaire with a Choice of Lenses. High Performance IP65 Rated Surface Mount Luminaire

IP65 Rated Emergency LED Luminaire with a Choice of Lenses. High Performance IP65 Rated Surface Mount Luminaire XYLUX LS IP65 3 cell NiMH 200 Lumens 3 Hours SELV IP65 Rated LED Emergency Luminaire Suitable for High-Bay, Open-Area and Escape Route Applications XYLUX LS IP65 is a high performance self-contained LED

More information

Details of the Han-Terminal block connector Han D AV Han D AV Distributor Han E AV Han ES AV

Details of the Han-Terminal block connector Han D AV Han D AV Distributor Han E AV Han ES AV Contents -Terminal Block Connectors Page Details of the -Terminal block connector........................ 08.02 D................................................... 08.10 D Distributor...........................................

More information

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Keor HPE UPS THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world

More information

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X 1. Use of the option modules There are two different housings with which these same plug-in units can be used namely: Calculator housing 1 (PolluTherm, PolluStat E and PolluFlow 2010) indicated by a lid

More information

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip Product Managers and dedicated Business Development Managers are available to assist with all your enquiries. Technical presentations (Forms of Separation, Discrimination etc) available Site response capability

More information

Decentral emergency- / safety-lighting system Type CLS 24/SV. Catalogue CLS 24 SV. Sicherheitstechnik GmbH

Decentral emergency- / safety-lighting system Type CLS 24/SV. Catalogue CLS 24 SV. Sicherheitstechnik GmbH Decentral emergency- / safety-lighting system Type /SV Catalogue SV Sicherheitstechnik GmbH /SV New standards allow new ideas! INOTEC Sicherheitstechnik GmbH is a medium-sized business creating innovative

More information

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2 > For use in hazardous areas with gas group IIB+H 2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

FC726 Fire control panel

FC726 Fire control panel FC726 Fire control panel FS720 series (MP3.0) Cerberus PRO Modular, prefabricated, microprocessor-controlled fire control panel with integrated user-friendly operating unit for up to max. 52 addresses

More information

IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...

IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact... IT monitoring Monitoring system system representation...446 system overview...448 Processing Unit/Compact...450 sensors/accessories control units/ sensors...45 Interface for CMC II sensors...45 Access

More information

SUNCLIX Connection technology for photovoltaics

SUNCLIX Connection technology for photovoltaics SUNCLIX Connection technology for photovoltaics Connection technology for photovoltaics Are you looking for innovative and reliable connection technology for your PV modules, inverters or the complete

More information

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras Edition: 3 from 15.11.2017 Supercedes the edition: 2 from 09.01.2017 EN** Features: Uninterruptible power supply of 8 IP cameras

More information

Voice Alarm System VX-3000 Series

Voice Alarm System VX-3000 Series Voice Alarm System VX-3000 Series Combined highly integrated voice alarm and public address system Highly Integrated Voice Alarm & Public Address System The issue of security is more than ever important.

More information

LED Conversion Kit LED conversion kit for use in emergency lighting applications.

LED Conversion Kit LED conversion kit for use in emergency lighting applications. 06/13 DS026 Issue 1 LED conversion kit for use in emergency lighting applications. Each conversion kit includes a driver module, LED lamphead with integral indicator and NiMH battery. Our conversion kits

More information

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras Edition: 4 from 15.11.2017 Supercedes the edition: 3 from 30.03.2017 EN** Features: Uninterruptible power supply

More information

Technical Concept. Tunnel Air Shower. All Types Air Shower / Air Locks

Technical Concept. Tunnel Air Shower. All Types Air Shower / Air Locks Technical Concept Tunnel Air Shower All Types Air Shower / Air Locks Tunnel Air Shower Technical Concept Product Description Personnel air showers minimize the transfer of dust particles on cleanroom clothing

More information

picture 1: Device components

picture 1: Device components Tronic rotary dimmer with soft-lock Order-No. : 2874 Operation- and Assembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure

More information

Technical information

Technical information Technical information Tender text Indoor wall and ceiling, surface-mounted luminaire Efficient replacement of CFL luminaires: : 1x18W (saves up to 60% energy)/ 1x26W (58%) CFL : 2x18W (60%)/ 1x32W (55%)/

More information

PRODUCT. Battery Charger

PRODUCT. Battery Charger PRODUCT Battery Charger Model : BC 9080 Battery Charger The ICD Battery Charger is designed to supply required DC Voltage and Current to the connected load and recharge the Battery on boost charging over

More information

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks COM465IP_D00217_04_D_XXEN/11.2018 Condition Monitor with integrated gateway for the connection

More information

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks COM465IP_D00217_00_D_XXDE/10.2015 Condition Monitor with integrated gateway for the connection

More information

Operating Instructions. DALI-Gateway

Operating Instructions. DALI-Gateway Operating Instructions 1. Safety instructions Electrical equipment must be installed and fitted by qualified electricians only. Failure to observe the instructions may cause damage to the device and result

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks COM465DP_D00216_00_D_XXDE/10.2015 Condition Monitor with integrated gateway for

More information

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Distributed by Keor T UPS THREE-PHASE UPS from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES T THREE-PHASE UPS T has been designed with advanced technologies and the

More information

Lighting Control System for Indoor Applications LIGHT CONTROLLER LW RADIO-OPERATED VERSION ENOCEAN RADIO-OPERATED CONTROLLER

Lighting Control System for Indoor Applications LIGHT CONTROLLER LW RADIO-OPERATED VERSION ENOCEAN RADIO-OPERATED CONTROLLER LIGHT CONTROLLER LW RADIO-OPERATED VERSION ENOCEAN RADIO-OPERATED CONTROLLER The radio-operated module of the VS Light Controllers is based on the established EnOcean technology. Communication between

More information