1 Installation guide
2 Outside world Property Wirepas mesh Mount Kelvin app Internet connection Ethernet DALI 3rd party integrations Mount Kelvin cloud Mount Kelvin central unit Voice control EnOcean wireless switch System description Mount Kelvin is a DALI / Enocean / Modbus room control system. For lighting control, the following components are used: 1. Wireless and battery-free EnOcean switches (see page 12) 2. DALI drivers for luminaires (see page 10) 3. DALI connected motion and light intensity sensors (see page 12) 4. Mount Kelvin application (ios and Android) 5. Amazon Echo voice control (see page 12) For more information please contact: support@mountkelvin.com Mount Kelvin control components are centrally installed on the DIN rail in the electrical switchboard. How to choose the correct Mount Kelvin central unit There are four types of Mount Kelvin central units. Choose the correct model from the list below: Mount Kelvin Medium, model number One Dali-controller installation (Helvar Helvar 402). Mount Kelvin Large, model number Two Dali-controller installation (Helvar Helvar 402). Mount Kelvin XL, model number Three or more Dali-controller installation (Helvar Helvar 402). Mount Kelvin Small, model number Only for small installations. Maximum 10 luminaire groups (wireless retrofit components). No Dali-compatibility. 2 Installation guide
3 Planning guide One DALI controller (Helvar 510) and one DALI power supply make up one controllable DALI universe. One DALI universe is capable of controlling 64 DALI addresses. Mount Kelvin recommends 55 DALI addresses per universe to ensure operational reliability. Please note that one driver might take up more than one DALI address (this is the case with RGBW drivers, for example). When the number of DALI addresses exceeds 55, we recommend splitting the universe into two universes. Fixed luminaires, lighting sockets, decorative luminaires and 230V controlled luminaires The manufacturers of fixed (or architectural) luminaires typically have a recommendation for a suitable DALI driver. We recommend using Malmbergs MD01 (230V DALI dimmer) and Malmbergs MD02 (230V DALI relay) for light sockets and decorative luminaires (230V). Malmbergs components consume one DALI address. RGB/RGBW strips For RGB/RGBW strips, select a four-channel DALI driver or type-8 DALI driver. When calculating DALI addresses, note that one RGB/RGBW driver will take three/four DALI addresses. Luminaire rails Both DALI rails and 3-circuit 230V rails can be connected into Mount Kelvin. DALI rails are simply connected to the DALI bus, 3-circuit rails are connected using three Malmbergs components. Motorized blinds/curtains Helvar 490 is a 2-channel blinds controller that allows control of blinds and curtains in Mount Kelvin. The blinds controller is a DIN-rail mounted unit that provides two independent control channels, each with two single-pole, volt-free contacts for switching up to 550 W up/down or power direction motors. The controller consumes two DALI addresses. Motion and presence sensors Mount Kelvin compatible sensors include Helvar 311 DALI PIR Motion Detector and Helvar 312 DALI PIR Motion Detector and Light Sensor (Standard Light Control). Please take the electric consumption of the motion sensors into account when planning the DALI universes. Each sensor consumes 15mA, and the DALI power supply supplies 250mA. Up to 16 motion sensor can be installed in one DALI universe, provided there are no other devices in the universe (15mA x 16 = 240mA). 3 Installation guide
4 AC L N E DALI Power Supply DA+ SC DA- DALI Controller DA- SC DA+ USB 5VDC Mount Kelvin Central Unit + - Power Supply L N Connections The picture shows a typical Mount Kelvin installation. Components from left to right: DALI power supply (Helvar 402), DALI controller (Helvar 510 includes Mount Kelvin DIN mount), Mount Kelvin central unit and power supply unit (Meanwell DR-15-5). DALI DA- DA+ ETHERNET Connections in the electrical switchboard 1. Attach the components to the DIN rail in the order shown above 2. Connect the power supply of the central unit (L, N) 3. Connect the power supply of the central unit to the central unit with the Micro USB cable supplied with the power supply. The Micro USB connector on the central unit is located in the upper left corner of the central unit. 4. Connect the EnOcean antenna to the central unit and take the antenna out of the electrical switchboard 5. Connect the Ethernet cable to the central unit 6. Connect the DALI controller to the central unit using the supplied Mini-B USB cable. The central unit has four USB ports. You can use any USB port. 7. Connect the DALI power supply to the DALI controller. Connect the power supply to the DA+ and DA- DALI controllers DA+ and DA terminals. 8. Connect the DALI power supply to 230V (L, N, E) Other Helvar DIN compliant components (if needed) 1. Connect the DALI controller (DA+ and DA-) from the DALI controller to the DALI bus (DA+ and DA-) of the Helvar unit 2. Chain the DALI bus for other Helvar components DALI- CONTROLLER L N D+ D- 5-POLE ELECTRICAL CABLE JOINT BOX DALI- DRIVER DALI- DRIVER DALI connections DALI wiring from DALI controller to DALI drivers. 4 Installation guide
5 Electrical cabinet charts / example 1 The name and the address of the constrcution Building measure Dimensions of the electrical cabinet EN and EN Type ESSV SSTL number EAN number Nominal current Rated voltage Water ingress Connection power Mass Rated voltage circuit Short circuit withstand capacity A nominal smoothing coefficient fuse / phase fuse / phase fuse / phase fuse / phase Nominal frequency: Protection against electric shocks: Protection class I Earthing system: TN system Environment: Normal, in accordance with 7.1 EMC operating environment: A and B GROUP CENTER RK Blueprint content MAIN CHART + ASSEMBLY IMAGE Design blueprint Modification C, Added integrated circuit breaker. Wire protector changes. Modification D, Information of the picture is updated as EN and -3 requires. Modification E, Added circuit breaker switch and wire protectors allocation switched. ACCESSORIES: Type Electric No. Designation Telecommunications installation enclosure Telecommunications installation enclosure Telecommunications installation enclosure Plinth for telecommunications installation enclosure Group center with circuit breakers and fault current protection switches. Surface and flush mounting. Door as standard. Code Inspector Conduct Modification Date Chart Designation Type Riser SMOKE DETECTORS FRIDGE + FREEZER Blueprint No. Scale Sheet Sheet HEATING, WATER AND DRAINAGE SYSTEM HEATING, WATER AND DRAINAGE SYSTEM HEATING, WATER AND DRAINAGE SYSTEM 5 Installation guide
6 Electrical cabinet charts / example 2 The name and the address of the constrcution Building measure Group center with circuit breakers and fault current protection switches. Surface and flush mounting. Door as standard. Chart Designation Type WASHING MACHINE / DRYER DISHWASHER STOVE STOVE STOVE GROUP CENTER RK Blueprint content Design blueprint MAIN CHART + ASSEMBLY IMAGE LIGHTING LIGHTING RELAY LIGHTING (W101) OUTDOOR SOCKETS VILLA SOCKETS RELAY LIGHTING (W102) RELAY LIGHTING (W103, W104) RELAY LIGHTING (W105) CONTROL Inspector Code Conduct Modification Date VILLA SOCKETS Scale Sheet Sheet Blueprint No. 6 Installation guide
7 Electrical cabinet charts / example 3 The name and the address of the constrcution Building measure Group center with circuit breakers and fault current protection switches. Surface and flush mounting. Door as standard. Chart Designation Type Micro USB cable Mount Kelvin Central Unit Mount Kelvin GROUP CENTER RK Blueprint content Design blueprint MAIN CHART + ASSEMBLY IMAGE Mount Kelvin DALI interface Mini USB cable DALI interface to Mount Kelvin Central Unit DALI 1 LIGHTING DALI + / DALI - BLACK / GREY DALI 2 LIGHTING DALI + / DALI - BLACK / GREY DALI 3 LIGHTING DALI + / DALI - BLACK / GREY DALI 4 LIGHTING DALI + / DALI - BLACK / GREY DALI 5 LIGHTING Code Conduct Inspector Modification Date DALI + / DALI - DALI 6 LIGHTING DALI + / DALI - BLACK / GREY BLACK / GREY (W101) Light rail MH 201 (W101) Light rail OH 202 (W101, W102) Outdoor wall lights 203 (W102) Light rail 205 Blueprint No. Scale Sheet Sheet (W102) Outdoor wall lights KT 206 (W104) Toilet mirror light (W103, W103) ground lighting 207 Reserved 7 Installation guide
8 Electrical floor plan / example Wireless and battery-free EnOcean switch Thermostat Electronic device Junction box Power socket, 1 pt. / protected socket, surface Power socket, 1 pt. / protected socket, flush Power socket, 2 pt. / protected socket, flush Power socket, 2 pt. / IP44, flush Electrical center Wall light fixture Spotlight Transformer, luminaire Heater Fire alarm 8 Installation guide
9 Designing large projects Master-Slave Large locations may have several electrical switchboards that include DALI controllers. These separate switchboards are compounded into a single system by a master-slave structure as follows: 1. The switchboards are connected by an TCP/IP ethernet local area network 2. All of the switchboards contain a Mount Kelvin central unit 3. One of the central units is designated as the master unit 4. The rest of the central units are slave units Now all of the separate DALI universes are configurable and controllable as one set of DALI universes. Wireless switch signaling in large projects The range of wireless switches in a built environment is approximately 30 m. When the signal from the switch to the central unit is bad, there are two ways to mend this: 1. Using Eltako FRP70 signal repeaters 2. Using Mount Kelvin slave central units Connecting of DALI controllers into to the central unit The Mount Kelvin central unit has four USB ports for connecting DALI controllers. In larger locations, it is possible that there are five or more DALI controllers in one electrical center. In this case, a USB splitter (USB hub) can be used to connect all DALI controllers to the Mount Kelvin central unit. Sensors Temperature and humidity sensor Wireless and battery-free temperature and humidity sensor Afriso FTM-TF can be connected to Mount Kelvin. It is possible to install a battery in the sensor if the sensor is in a darker room. You can monitor the temperature and humidity of the premises via the app. Water leakage sensor Wireless and battery-free Water leakage sensor Water Sensor Eco can be connected to Mount Kelvin. In the event of a water damage, the user receives a text message alarm. With Mount Kelvin, it is possible to control the object relay-driven solenoid valve (requires Helvar 498/494 relay unit). When water leakage occurs, Mount Kelvin closes the water supply. CO 2 sensor The Afriso CO2 sensor is plugged into a socket. You can monitor the CO2 content of the premises via the app. 9 Installation guide
10 Required components Mount Kelvin central unit * Dimensions (mm): 70 x 90 x 62 Power supply for CU (Meanwell DR-15-5) Dimensions (mm): 25 x 93 x 56 DALI controller (Helvar Digidim 510) Dimensions (mm): 36 x 44 x 58 DALI power supply (Helvar Digidim 402) Dimensions (mm): 35 x 58 x 90 EnOcean antenna How to choose the correct central unit? There are four types of Mount Kelvin central units. Choose the correct model from the list below. Mount Kelvin Medium model number One Dali-controller installation (Helvar Helvar 402). Mount Kelvin Large model number Two Dali-controller installation (Helvar Helvar 402). Mount Kelvin XL model number Three or more Dali-controller installation (Helvar Helvar 402). Mount Kelvin Small model number Only for small installations. Maximum 10 luminaire groups (wireless retrofit components). No Dali-compatibility. Wired ethernet internet connection 10 Installation guide
11 Additional components DIN rail components (control through DALI) Helvar Digidim 454 / 4-channel dimmer unit Dimensions (mm): 160 x 91 x 62 Helvar Digidim 498 / 8-channel relay unit Dimensions (mm): 160 x 90 x 58 Helvar Digidim 494 / 4-channel relay unit Dimensions (mm): 88 x 90 x 58 Helvar Digidim 474 / 4-channel 1-10V controller Dimensions (mm): 160 x 90 x 58 Helvar Digidim 478 / 8-channel DALI broadcast controller Dimensions (mm): 160 x 90 x 62 Helvar 490 / 2-channel blinds controller Dimensions (mm): 88 x 58 x Installation guide
12 230V dimmers and relays Malmbergs MD01 / DALI 230V dimmer Dimensions (mm): 77 x 51 x 23 Malmbergs MD02 / DALI 230V relay Dimensions (mm): 77 x 51 x 23 Motion sensors Helvar Digidim 320 DALI PIR motion sensor Dimensions (mm): 66, height: 62 Mounting hole diameter: Helvar Digidim 321 DALI PIR motion sensor and light intensity sensor Dimensions (mm): 65, height: 49 Mounting hole diameter: Wireless switches Mount Kelvin uses wireless and battery-free 868 MHz EnOcean switches. Mount Kelvin recommends Gira EnOcean switches to ensure the best quality and click-feel of the switches. Available colors: anthracite, glossy white, aluminium and stainless steel. Amazon Echo Voice control your lights. Echo Dots are available in black and white. Requirements for setting up Mount Kelvin + Alexa: Mount Kelvin central unit and computer or phone. Rooms and scenes need to be named in English. Installation instructions: 1. Create an Amazon account and begin setup at alexa.amazon.com. 2. Search and enable Mount Kelvin skill. Insert key and connect. 3. Search your existing Mount Kelvin rooms and scenes: Alexa, discover new devices 4. Timezone settings are in alexa.amazon.com > Settings > xxx s Echo Dot 5. Just try it and speak to Alexa: Alexa, lights on. Alexa, turn off kitchen. Alexa, turn on evening lights. 12 Installation guide
13 Verkkosaarenkatu Helsinki, Finland mountkelvin.com Technical support Lauri Haro lauri.haro@mountkelvin.com
ECL Comfort V a.c. and 24 V a.c.
Data sheet ECL Comfort 200 230 V a.c. and 24 V a.c. Application The ECL Comfort 200 electronic controller is pre-programmed for a variety of different applications. Each application has its own card describing
More informationScreenLine Accessories MB model
ScreenLine Accessories MB model ST2121 Control Module 1 group of blinds (PC configuration) control (Potential separated) Individually configurable via Configuration Utility (PC) DIN rail mounting Dim.:
More informationSmart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating
Smart heating system with wireless thermostats & smartphone control for every room Get the most out of any water based underfloor heating DETAILED OVERVIEW Control the heating in your home from anywhere.
More informationGeneral catalogue Export SMOUTS ARCHITECTEN
General catalogue 2011-2012 Export SMOUTS ARCHITECTEN 01 NIKO HOME CONTROL INTERIEUR DEWAIDE Project management Configuratie Installatie Help Niko Home Control (available from 1 August 2011) Live it, love
More informationLINE 21 INTERNET ACCESS THROUGHOUT THE HOUSE
LINE 21 INTERNET ACCESS THROUGHOUT THE HOUSE Fed up with your Internet access being restricted to a single room? Would you like access available in any room in the house that has a telephone socket? For
More informationsimple to install easy to operate very flexible creates the perfect mood DIGIDIM Router System l i g h t i n g t h e w a y f o r w a r d
simple to install easy to operate very flexible creates the perfect mood DIGIDIM Router System l i g h t i n g t h e w a y f o r w a r d Step Towards Flexibility Helvar is a leading company in architectural
More informationCasambi CBU-ASD. Bluetooth 4.0 Wireless Control Unit for LED Drivers. Features. 1 Description
Casambi CBU-ASD Bluetooth 4.0 Wireless Control Unit for LED Drivers Features Wirelessly controllable with a smart device. No need for an external gateway device. Forms automatically a fast wireless mesh
More informationINTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE
INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE In times where energy conservation is a top priority for all progressive enterprises, the measurement of flow rates and consumption is becoming more and
More informationsonnen Installation Practical
sonnen Installation Practical sonnen Components sonnenbatterie eco 8.0 Single Phase System Components 4 sonnenbatterie eco 8.0 Single Phase System Components 5 sonnenbatterie eco 8.0 Single Phase System
More informationSpecialized Lighting Solutions, Inc. SLS DALI CONTROLLERC
DCP-A Panel Network DALI Control Panel for DALI Ballast, DALI Relays and DALI Dimmers 24 20 6 The DCP-A electronic network control panel with Clipsal DCDALCIP250-2 serial interfaces supports applications
More informationInstallation and User Guide
D5 Installation and User Guide 8-Channel DALI Controller (478) Introduction The 478 is for controlling DALI ballasts, drivers and load interface units (except for the 490 Blinds Controller). Do not connect
More informationLighting Control System for Indoor Applications LIGHT CONTROLLER LW RADIO-OPERATED VERSION ENOCEAN RADIO-OPERATED CONTROLLER
LIGHT CONTROLLER LW RADIO-OPERATED VERSION ENOCEAN RADIO-OPERATED CONTROLLER The radio-operated module of the VS Light Controllers is based on the established EnOcean technology. Communication between
More informationSecure Your Way of Life. Now Compa ble With. HSVGW-G Series Home Security Voice Gateway Series. Take Smart Living Up a Notch
Secure Your Way of Life Now Compa ble With HSVGW-G Series Home Security Voice Gateway Series Take Smart Living Up a Notch Home Security Voice Gateway Series Heart of your smart home, now made even better.
More informationMonitoring Made Easy. October 2015 APRIL 2015
Monitoring Made Easy October 2015 APRIL 2015 About Packet Power Founded in 2008 Based in Minneapolis, MN Global partner network Customers on 6 continents Over 30,000 monitoring units deployed 2 Our goal
More informationMain Controller with Gateway EL-M01
S M A R T f o r y o u r h o m e P r o d u c t c a t a l o g u e 1 CONTROLLERS 2 Main Controller with Gateway EL-M01 ON BUS NET STATUS DIMM EXPAND 1 1 2 3 4 www.entia.si MAIN Main Controller w/ GW UTP NET
More informationComplete Lighting Control
Complete Lighting Control simple to install easy to operate very flexible creates the perfect mood Complete Lighting Control Imagine the Scene... a boardroom presentation... an intimate dinner at your
More informationINTRODUCTION Busch-SmartTouch KNX. The 7 SmartTouch
INTRODUCTION The 7 SmartTouch Motivation and objectives - your smart display for the smart buildings of today. A smart display with many integrated applications for smart buildings, like KNX controls and
More informationDupline Fieldbus Components
Dupline Fieldbus Components Channel Generators/Interfaces Types D390 G300 G396 G39 Standard channel generator. 77 x x 70 Controller and Modbus Interface with built-in GSM Modem (option) or external Radio
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationLighting Control System for Indoor Applications LIGHT CONTROLLER L LIGHT CONTROLLER L
LIGHT CONTROLLER L LIGHT CONTROLLER L The VS Light Controllers are light management systems that were developed to control and regulate light independently of PCs and higher-order bus systems. Communication
More informationSwitched Mode Power Supply Operating manual PAP800
Features: Switched mode power supply Wide output 0 144Vdc Analog control by an external 0 5Vdc Power failure alarm output Master-slave connection Powerfinn PAP series is a high power, lightweight, advanced
More informationeblue 0-10V / DALI Datasheet
Datasheet Bluetooth 4.0 Wireless Control Unit for LED Drivers The information in this document is subject to change without notice and should not be construed as a commitment by ELT. Please, check for
More informationDM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY
DM650TM UNIVERSAL RTD OR THERMOCOUPLE INPUT BATTERY POWERED USB AND NFC INTERFACE ALARM RELAY / USER SET DISPLAY MESSAGES 5000 POINT DATA LOGGER INTRODUCTION The DM650TM battery powered indicator accepts
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationSee instructions to download and install the latest version of LinkBoxEIB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationTechnical Manual Nova: Cabinet Security Management System (CSMS)
Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova
More informationLighting Controls and Connectivity DALI sensors. MSensor G3 SFI 30 PIR 10DPI WH Multi-sensor
MSensor G3 SFI 30 PIR 10DPI WH Multi-sensor Product description Sensor developed to work with the latest DALI specification Monitoring of ambient light and motion detection Remote control interface allowing
More informationIT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...
IT monitoring Monitoring system system representation...446 system overview...448 Processing Unit/Compact...450 sensors/accessories control units/ sensors...45 Interface for CMC II sensors...45 Access
More informationAC5160 SiPass integrated controller kit
AC5160 SiPass integrated controller kit SiPass integrated Wall housing with pre-assembled basic SiPass integrated components Equipped with one ACC (AC5100), two dual reader interfaces (ADD5100) and one
More informationGrow your business by providing an intuitive home safety and comfort experience
Grow your business by providing an intuitive Self-contained, wireless security and interactive home automation system Fire detection s Video cameras Locks S.O.S./panic buttons Key features and benefits
More informationTechnical Datasheet clima RCM-CC
Technical Datasheet 1. Product description The is a room control panel with an integrated temperature sensor for measuring the room temperature. The device is featured with a turn wheel to adjust the set
More informationVENTILATION BUTTONS 24 V DC
VENTILATION BUTTONS 24 V DC Ventilation button (with foil push buttons and displys) Application: Ventilation button for connection to the ventilation inputs of SHEV or natural ventilation control units.
More informationSelectronic accessories to support the SelectSun 3 phase grid-tie inverter range
Selectronic accessories to support the SelectSun 3 phase grid-tie inverter range Our all new SelectSun range of 3 phase solar inverters are equally at home with or without batteries. Available in 20kW
More informationTROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K
.2 X X testregistrierung TROXNETCOM AS-i Communication interface between a component and the controller The module is used to connect the control system with the components Integral AS-Interface slave
More informationOperating and mounting instructions
General Usage IPAS DALI Gateways bring together the crossfunctional KNX installation bus and the lighting control specific DALI-Bus (IEC 60929). Lights with cost-effective, digital DALI ECGs can therefore
More informationAccess Terminal IF-800
95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller
More informationEmergency. Lighting. CATALOGUE Vol. 01. Decentralised and centralised supply
Emergency CATALOGUE Vol. 01 Lighting Decentralised and centralised supply Light is safety Light must be safe! Interior luminaire, exterior luminaire and emergency luminaire are all important to ensure
More informationIF-80x Outdoor Terminal
95-10330_IF-800 V2016-10-20 Outdoor Terminal IF-80x Outdoor Terminal 1 IF-800 Outdoor / IF-801 We are pleased that you have decided to use a terminal of the IF-80x series for recording access data. Scope
More informationSee instructions to download and install the latest version of LinkBoxLON and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationThe ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.
ECL Apex 20 controller and ECA 20 (ECL Apex Web Panel) Description ECL Apex 20 and ECA 20 ECL Apex 20 The ECL Apex 20 and the ECA 20 (ECL Apex Web Panel) are used in large district heating applications.
More informationx x 60 mm, 700 gm. Wall mounted enclosure, 1 Kg. Weatherproof, high impact GF ABS. Remote control and monitoring with debug features
Smart Hub Intelligent Energy Management and IoT Hub Unit (CT200i) General Dimension and weight 202.73 x 267.45 x 60 mm, 700 gm Dimension with standard cover 268 x 204 x 56 mm Dimension with weatherproof
More informationChapter 11 Lighting management
Chapter 11 Lighting management 11 Lighting Management This is what lighting management achieves creating an atmosphere of well-being reducing carbon dioxide immissions detecting movement and switching
More informationbasicdim Wireless Wireless module for basicdim
Wireless Wireless module for Product description Wireless controllable with a Android / ios smart device o need for an external gateway device Forms automatically a wireless communication network with
More informationIntesisBox KNX - AIRZONE
IntesisBox KNX - AIRZONE Gateway for the integration of Airzone InnoBUS into KNX systems. Full integration of Airzone InnoBUS air conditioning with KNX control systems. CS CS KNX EIB Bus IntesisBox RS485
More informationMillenium II +: general characteristics
Millenium II +: general characteristics Starter kit Blind Temperature sensors Special starter kits Bare board Power supply Level detection Local extensions Accessories Standard Expandable Adjacent extensions
More informationEMS10 - EMS50. Cameo specification sheet. Product Description
Product Description Wall Mount Fist Microphones 10, 20 or 50 Selection Buttons EN54 Compliant Indicators and Controls EN54 Fault List Display Speech Level VU Bargraph Fully Monitored Hardware Bypass Fallback
More informationM-Bus Central Unit. Use
6 M-Bus Central Unit OZW The M-bus central unit is used for the remote readout, remote operation and supervision of an M-bus plant with a maximum of consumption meters and controllers featuring an M-bus
More informationisma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland
isma-b-fcu User Manual FCU Hardware Global Control 5 Sp. z o.o. Warsaw, Poland www.gc5.pl Table of contents 1 Introduction 3 1.1 Document change log 3 1.2 Safety rules 3 1.3 Technical specifications 4
More informationBUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features
BUILDING MANAGEMENT OpenBAS-HV-NX10 SERIES Description Mircom s OpenBAS-HV-NX10 series of Building Automation Controllers are aimed to provide various HVAC, energy management, and lighting control solutions
More informationSupplementary operating instructions for your air curtain system Controller TMC 500
Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016
More informationLightRules Network Infrastructure
System and Hardware Specifications LightRules Network Infrastructure The LightRules network infrastructure enables communication and data transfer between Intelligent Light Engines, the LightRules Appliance,
More informationB.ONE HUB COMPATIBLE DEVICES
B.ONE HUB COMPATIBLE DEVICES AUDIO DEVICES LIST OF COMPATIBLE DEVICES http://b1hub.com Page 1. SONOS PLAY 1 5 2. SONOS PLAY 3 5 3. SONOS PLAY 5 5 LIGHTING 1. CREE CONNECTED BULB(ZIGBEE) 6 2. PHILIPS HUE
More informationMobileView Junction Box
Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard
More information2017 xxter bv. All rights reserved. Alexa and Amazon Echo are trademarks of Amazon.com, Inc. More information can be found at
Manual Version 1.0 October 2017 2017 xxter bv. All rights reserved. Apple, ipad, ipad Air, iphone, and ipod touch are trademarks of Apple Inc., registered in the U.S. and other countries. HomeKit is a
More informationapplication sheet RAKO CONTROLS WIRED RAK OVERVIEW
WDA-600 application sheet Introduction When installing a wired system dimmers are typically housed in RAK boxes with either 8 modular cards (RAK8) or 4 fixed type controls (RAK4). These are typically mounted
More information24/48V Battery Bank Ah High Cycling Long Life
Outdoor Power Cabinets, 48V DC Free Cooled with Combined Air-Con. PreFactory assembled with 19 inch Power sub rack, 2 or 4 battery Shelf s, 3U DCAC Panel combined with rectifiers 2U or 4U Power Module
More informationHelvar Designer 5 Foundation Course: Initial programming
Helvar Designer 5 Foundation Course: Initial programming Edition 1 (10 th May 2018). Helvar Designer 5 Foundation Course: Initial Programming. Edition 1 Page 1 of 99 Contents A: BEFORE GOING ONLINE...
More informationSystem Installation guide
System Installation guide Ligo System installation guide V3 newestpage 1 of 14 Contents 1 INTRODUCTION... 3 2 SYSTEM TOPOLOGY... 3 3 CONTROL ELEMENTS... 4 3.1 LIGO CONTROLLERS... 4 3.2 IP DOMAIN... 5 3.3
More informationDLX1224 multi channel BLE
pag. 1/8 FEATURES BLUETOOTH+SEQUENCER+FADER+DIMMER+DRIVER DC Input 12-24 Vdc RF Command: Bluetooth low energy Local Command: Push Buttons Control: Dimmer, Tunable White, RGB or RGBW Color Current outputs
More informationLUMIOS MkIII Luminance Photometer for Tunnels
Designed specifically measurement of luminance at the tunnel portal or within the tunnel CIE Approved measurement of L20 Variable viewing angle within a range of 10 to 40º available Silicon photo diode,
More informationTECHNICAL DESCRIPTION
MPi80HD TECHNICAL DESCRIPTION 1 GENERAL DESCRIPTION The MPi80HD system is designed to convert AC mains voltage into 48 VDC and to supply telecom equipment with battery back up. The MPi80HD can house up
More informationElectrical Demand Specification (Reference SOP: )
Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3
More informationInstallation Instructions Temperature transmitter TAA /00 06/2011
Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to
More informationBlue e+ chillers with the principle
Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide
More informationNetSense Core Node EX
NetSense Core Node EX datasheet Externally mounted NEMA Connector The Sensity Systems Core Node EX is an integral part of our NetSense platform - an open architecture-based light sensory network that can
More informationVersion 1.1 March 2018
Manual Version 1.1 March 2018 2018 xxter bv. All rights reserved. Apple, ipad, ipad Air, iphone, and ipod touch are trademarks of Apple Inc., registered in the U.S. and other countries. HomeKit is a trademark
More informationPHS Series. PowerHUBB Node - Satellite
PHS Series PowerHUBB Node - Satellite Project Name NETWORK Catalog No. Date The Hubbell Control Solutions' (HCS) PowerHUBB node provides power distribution architecture and data connectivity to create
More informationEC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method
Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available
More informationLDALI ME204-U, LDALI ME201 U
Functions BACnet/ Controller L ME204-U, L ME201 U BACnet CEA 709 Modbus OPC Datasheet #89021219 L WEB, L STUDIO L Controllers are multifunctional devices combining constant light con trol, sunblind control
More informationProduct Brochure Edition 1. t: f: e: doncastercables.com
Product Brochure Edition 1 t: 01302 821700 f: 01302 821701 e: sales@ LED Highbay Ultra efficient up to 140 Lumen/Watt Superbly reliable MEANWELL HGB driver 1-10V dimmable as standard Latest LED technology:
More informationDIRIS Digiware D and C Communication and control power interfaces
Multi-circuit metering and measurement diris-dw_006_a_us_cat diris-dw_142_a The solution for > Industry > Building > Infrastructure > Data centers DIRIS D-40/D-50/D-70 Centralization and display of data
More informationINDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET
INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET 1 Contents ETHERNET Switches ECO and Standard 3 4 SFP Modules Interface for Fiber-Optic 5 ETHERNET Switches Managed 6
More informationSafety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationSee instructions to download and install the latest version of LinkBoxEIB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationGladiator Lift Services Ltd OPTIO MRL Controller Specification
Gladiator Lift Services Ltd OPTIO MRL Controller Specification 1 Control System Specification General Requirements Control Cabinet A new MRL control panel shall be provided being of the enclosed steel
More informationBMCS CCX Cabinet. BMCS_CCX Cabinet is secured via a switchable 6A circuit breaker. Note the right selectivity ratio of your feeding.
Version: 2011-01-13 BMCS CCX Cabinet Description & Function: The BMCS_CCX Cabinet is a ready to install wall housing for one or more BMCS systems (see figures 1 to 3). The BMCS_CCX Cabinet is designed
More informationidim Standalone idim idim Sense (316) (Master ) idim Ballast s idim Sol o Multisensor (312), (PIR extension) idim Sense (316) (PIR extension)
) ( idim Standalone idim Multisensor (), (PIR extension) (PIR extension) (Master ) RJ Style PC Cable 0 V LI 6 ma idim Ballast s L N www.helvar.com idim Sol o SW Interface Modul e com 00-0 V 50-60Hz SW
More informationSmartStruxure SmartStruxure Lite ZENO InnPoint. ZENOcontrols.com. compatible with
Room Controller Low Voltage Fan Coil Controller and Zone Controller Application specific controller with customizable covers and screen colours. The is a low voltage fan coil terminal equipment controller
More informationSECTION SWITCHBOARDS
SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS
More informationWireless Control Systems
Wireless Control Systems Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Receivers Accessories Programming Switching & Dimmer Functions
More informationSmall and Medium Building New and Renovation Prescription Assistance Complete Solution
Small and Medium Building New and Renovation Prescription Assistance Complete Solution 1 1) Introduction... 3 2) Control/Automation of the building... 4 2.1) Control interfaces... 4 2.1.1) Commands by
More informationBuilding Automation KNX. Conservatory Automation
Building Automation KNX Conservatory Automation New Products April 2010 Sensors The Weather Station Suntracer KNX-GPS provides the current meteorological data (brightness, wind speed, pecipitation and
More informationIntesisBox Modbus Server Panasonic
IntesisBox Modbus Server - Panasonic Gateway for Panasonic ECO-i VRF and PAC-i system integration into Modbus Systems Master Up to 30 Outdoor units Up to 64 Indoor units Modbus TCP Master /EIA232 PA-AC-MBS-64/128
More informationYour process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this
Overview Signal converters Your process requires the utmost attention Our new signal conditioners support you in achieving this Many process parameters in your system are handled by your control system,
More informationControl4 DIN Rail Lighting
Control4 DIN Rail Lighting Life s Better When Everything Works Together Want to change the moods and atmosphere in each room of the house? Using conventional lights, energy saving lights, LEDs and want
More informationMULTICHANNEL DATA RECORDERS
MULTICHANNEL DATA RECORDERS Introduction ma + V / mv RTD + - universal inputs + - TC universal inputs: RTD + TC or U + I (SRD-99) fixed inputs: RTD, TC, U, I (SRD-N16) 2 relay outputs memory up to 3 000
More informationExpansion Module HZS 541-1S
Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs
More informationRichmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green
Richmond Heights Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller Presentation Agenda 1. Introduction To Richmond Heights 2. Smart Universal Controller Features Of DAS-G01 3. DAS-G01
More informationHumidity transmitter for critical climate applications
Humidity transmitter for critical climate applications testo 6651 Optimum adjustment concept thanks to adjustability of the entire signal chain incl. analog adjustment Ethernet, relay and analog outputs
More informationWE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE
WE CONNECT REAL WORLD TO THE STRUCTURAL MONITORING SENSORS WIRELESS INTERFACE SOFTWARE CLOUD Rev.10 del 3/10/017 Redatto da: R&D e MKT Approvato da: CEO Smart structural WIRELESS Interface NI00 devices
More informationPDU Solutions. PDU Solutions
Canovate offers a full range of PDU s from basic and metered ones to IP PDU s with per socket switching capability and wireless sensor connectivity. Our PDU s can be used in the most complex ISP and Colocation
More informationDesigned for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.
Gateways from M-Bus/wM-Bus to Modbus TCP/IP Benefits SIU-MBMs are gateways that transform data from the M-Bus and wireless M-Bus protocol into the Modbus TCP/IP protocol, to then send them to a master.
More informationIT power distribution Power distribution units (PDU) Basic. Versions available:
IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,
More informationFixture-Integrated Sensor based on Bluetooth mesh
Fixture-Integrated Sensor based on Bluetooth mesh Converts uminaires into Multifunctional IoT Devices Bluetooth mesh 0-10V Dimming Control Motion Sensor Fixture Integration Ambient ight Sensor Autonomous
More informationMICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS
MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller /
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More informationLC35SE-DA W SELV Dimmable DALI-2 LED driver. 35 W V 0/ Hz. Functional Description. Mains Characteristics
35 W SELV Dimmable DALI-2 LED driver DALI-2 certified LED driver, 1-100 % dimming range SELV output protection for safety and flexibility in luminaires Amplitude dimming for the highest quality light output
More informationSafety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More information