Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

Size: px
Start display at page:

Download "Operation Manual Profibus DP -Display HE 5120 P with digital I/O's"

Transcription

1 Operation Manual Profibus DP -Display HE 510 P with digital I/O's "HESCH" Schröder GmbH Boschstraße Neustadt Telefon +49 (0) 503 / Telefax +49 (0) 503 / info@hesch.de

2 General Operation Manual: HE 510 P Date: Art.-No.: The digital display HE 510P operates as display, Set-Point device and as a slave I/O unit in Profibus DP networks. The digital display HE i510 P supports the cyclic data communication according to the PROFIBUS DP standard EN Optional services released later e.g. the acyclic data communication, are not supported by the display. With the PNO the following data were registered: ID number: 08C5 Model name: HE 510 P Name of the producer: HESCH Schroeder GmbH Output status: 1.00 Master/Slave: Slave GSD file: HE 08C5.GSD ( = x underline) The GSD file is loadable from the Internet > products > field bus > HE510P > HE510P_GSD.zip. Supported Service Access Points (SAPs) Default SAP data exchange (Write_Read_Data) SAP56 reading of the inputs (Read_Inputs) SAP57 reading of the outputs (Read_Outputs) SAP58 control command at the DP Slave (Global_Control) SAP59 configuring data read (Get_Config) SAP60 read diagnostic information (Slave_Diagnosis) SAP61 parameter data transmit (Set_Param) SAP6 configuring data check (Check_Config) The HE 510P can be operated alternatively as process value display or as set-point device. Additionally the device is provided with three digital outputs and 4 digital inputs. If the device is used in the display mode further inputs are available. For the use as setpoint device an optional rotary pulse encoder is necessary. The device is suitable for the connection to 4 V DC. Pay attention to the correct value of the operating voltage. Otherwise the device will be destroyed. Safety Instructions ESD! contains electrostatically sensitive components Original packing protects against electrostatic discharge (ESD) Transporting only in the original packing during mounting rules for protection against ESD must be followed Connections Wiring must be conform to local standards (e.g. VDE 0100 in Germany)! Input leads must be kept separate from signal and mains leads! The protective earth must be connected to the relevant terminal The cable screening must be connected to the terminal for grounded measurement! Usage of twisted and screened input leads prevent stray electric interference! Connections must be made according to the connecting diagrams! Maintenance / Repair Instrument needs no particular maintenance. When opening the instrument live parts or terminals can be exposed. Before carrying out the instrument must be disconnected from all voltage sources. The instrument contains electrostatically sensitive components. The following work may be carried out only by trained, authorized persons. Fuse tripped: Cause must be determined and removed! Only fuses of the same type and current rating as the original fuse must be used. Page

3 Address Terminals Device address The address is set with a DIP- switch block behind the red plexiglass. For this purpose the black frame has to be pulled off. The red pane is then removable Address (factory setting) Valid addresses are All other adjustments lead to the error message: ErrId. A switch in the position off (in the picture left) has the value 0, a switch in the position on (in the picture on the right) has the value 1. The individual switches are numbered top down (1... 8). Switch 8 does not have a function. Connection Diagramm VDC 17 In 4 16 In 3 15 In 14 In 1 13 Out 3 1 Out 11 Out VDC 9 8 up(in5)* 7 down(in6)* 6 VP 5 RxD/TxD-N 4 RxD/TxD-P 3 DGND 4 V DC 1 + Digital In 4 V Digital Out 4 V/ 0, A (total) Rotary Pulse Encoder (Option) as setpoint sensor* Interface Profibus DP Supply *If not used as a setpoint device, term. 7 and 8 are two more inputs. Page 3

4 Commissioning Commissioning Connect supply 4V DC Connect bus. Consider polarity: GND:[3] Tx-P:[4] TxN:[5] VP:[6] - Connect shield (screen) of wire to earth and connect also to subsequent lines. - If last device at bus: terminate with resistance network Do not terminate short branch lines(stubs)! If used as set point device: connect rotary pulse encoder. Address setting: pull off black frame take off the red pane, see little notch in the up right corner, address setting according to table on Page 3. Switch on supply Configure the device with Profibus configuration software program. Possible Errors Bus not connected Node number already used from another participant. TxD-P and TxD-N interchanged Shield connection interrupted. Shield connected to - []. P and N interchanged with termination. Load at digital outputs exceed 0. A. Voltage at digital inputs to high. Rotary pulse encoder not connected in set point mode. Device messages ErrId b-off Para CFG No valid address has been set. No bus connection Parameter error Configuration error Page 4

5 Bus Termination Set-Point Device Bus Termination The bus line has to be terminated at both end with a correct resistance network. Short branch lines do not need a termination. Better than producing branch lines is the correct interconnection in the Profibus data line. The shield of the line is to be attached at the function earth (metal housing), however not at - [ ]. VP(5V)[6] TxD-P[ 4] TxD-N[ 5] 390R 0R 390R * A resistance network is necessary, if the device is the last users of a Profi bus. Please notice the sequence of terminals! DGND[3] Profibus Profibus* Set-Point Device (optional equipment) The device's delivery is complete with attachment and connection wire ,6 Leitung wire Ø6 l= 300 Ø9 18,6 8 All dimensions in 'mm'. 17 ca. 50 Page 5

6 Software Configuration The device master file HE 08C5.gsd and the symbol icons had to be copied into the correct directory of the network setup programm. The Gsd - file is downloadable: >Produkte >Feldbus >HE510P >HE510P_GSD.zip. The HE510P is listed under: "Other Fieldbus Devices". The representation depends on the used network configuration tool and may deviate from this representation. The desired functionality is selected and made known to the other network participants. Page 6

7 Display Word/Bit-Allocation Modul Display 16bit Profibus-Master to HE510P Wordnumber Wordnumber Meaning Type 1 Display Value signed int16 Control Word unsigned int16 Display Value: Value which is shown on the display. Values outside of the allowed area ( ) are not accepted. Invalid values are reported in the diagnosis information. Modul Display 3bit Profibus-Master to HE510P Meaning Type 1 + Display Value signed int3 3 Control Word unsigned int16 Display Value: Value which is shown at the display. Values outside of the allowed area ( ) are not accepted. Invalid values are reported in the diagnosis information. The control word has the following structure: Bit Usage Function 0 Display switch 0 Display ON; 1 Display OFF 1 Display flashing 0 flashing OFF; 1 flashing ON Decimal point 1 0 OFF; 1 ON 9 Decimal point 0 OFF; 1 ON 10 Decimal point 3 0 OFF; 1 ON 11 Decimal point 4 0 OFF; 1 ON 1 Unit 1 Led 0 OFF; 1 ON 13 Unit Led 0 OFF; 1 ON 14 Unit 3 Led 0 OFF; 1 ON 15 If more than one decimal point is activated, the last valid status will be continued. If more than one unit led is selected, the last valid status will be continued. Page 7

8 Counter Word/Bit-Allocation Modul Counter 16bit Profibus-Master to HE510P Word Number Meaning Type 1 Preset Value signed int16 Control Word unsigned int16 Preset Value: Value which is loaded in the Counter, if the control bit 'Preset Counter' is set. Values outside of the allowed area (Counterlimit min... Counterlimit max) are not accepted. Invalid values are reported in the diagnosis information. The control word has the following structure: Bit Usage Function 0 Display switch 0 Display ON; 1 Display OFF 1 Display flashing 0 Flashing OFF; 1 Flashing ON 3 4 Counter hold 0 Counter released; 1 Counter locked 5 Counter Reset 1 Counter to zero 6 Counter Preset 1 Load Counter Preset Value 7 8 Decimal Point 1 0 OFF; 1 ON 9 Decimal Point 0 OFF; 1 ON 10 Decimal Point 3 0 OFF; 1 ON 11 Decimal Point 4 0 OFF; 1 ON 1 Unit 1 Led 0 OFF; 1 ON 13 Unit Led 0 OFF; 1 ON 14 Unit 3 Led 0 OFF; 1 ON 15 If more than one decimal point is activated, the last valid status will be continued. If more than one unit led is selected, the last valid status will be continued. HE510P to Profibus Master Word Number Meaning Type 1 Counter Value signed int Counter Value: actual counter value of the HE 510 device. Page 8

9 In/Output Word/Bit-Allocation Modul Digital Output Profibus Master to HE510P Byte Number Meaning Type 1 Output Value Byte Output Value: Bit by bit organisation of the outputs. Bit 0 = Output 1 Modul Digital Input HE510P to Profibus Master Byte Number Meaning Type 1 Input Value Byte Input Value: Bit by bit organisation of the inputs. Bit 0 = Input 1 If the device is operated as Display, then 6 inputs are transferred, Is the device operated as Counter, then 4 inputs are transferred. Display Functionality Unit LED* N 1 3 Dezimalpunkt Decimal point * In order to identify a displayed process value unique, a Unit LED can be assigned and triggered. (Control Word/-Bit 1-14 see page 7,8) Page 9

10 Applications Example 1: Air Shutter Control Manual control, digital and analog indications on site P P ϑ.identification of the 'actual' displayed process value. LED-1 simultaneously with display: "Pressure" LED- simultaneously with flashing display: "Over Pressure" LED-3 simultaneously with display: "Temperature" Out 1 Out 1 Out In 1 In In 3 In Air Shutter closing Air Shutter Closed Alarm Over Pressure Air Shutter Closed Over Pressure Air Shutter closing Air Shutter opening In 6 In Manual Automatic On Site Security Switch Example : Water Conditioning 3 x Volumetric Flow Rate On-Site Display and Adjustment.Identification of the actual displayed process value. G/s1 LED-1 simultaneously with display: "Flow Rate 1" G/s LED- simultaneously with display: "Flow Rate " G/s3 LED-3 simultaneously with display: "Flow Rate 3" Out 1 Out 1 Out In 1 In In 3 In Outlet1 open Outlet open Outlet 3 open Selector to identify the individual flow rate Acknowledgement for flow rate value In 6 In Up Down Manual rotary pulse switch/ Set-Point device (Hesch) Release and reset may be performed from the Profibus-Master werden Several display functions, all I/O's, setpoints and actual values can be transmitted per Profibus. Page 10

11 Technical Data HE 510 P Displays: 7 segment display with 5 digits, 13 mm of character height 3 LED s ( mm) freely controllable via Profibus. Display range: to 99999, decimal point freely selectable Interface: PROFIBUS DP in accordance with EN Baud rate up to 1 MBaud Automatic Baud rate detection Address range: Galvanic isolation Input/outputs: 6 digital inputs, 4V DC 3 digital outputs, 4V DC, sum output current 00mA Adjustments: 1 DIP switch for node address Supply: 4 V DC ( V DC) Housing: Installation into control panel housing according to DIN 43700, Front: Filter disk, red Dimensions: 96 x 4 x 110 mm (W x H x D) Cut-Out: 93 x mm (W x H) Class of protection: Front IP54 acc. to EN 6059 Electrical connection: Screw-/plug-in terminals Ambient temperature: 0-50 C (3-1F) Scope of supply: Device, mounting material, Short manual for installation and commissioning Accessories: Rotary pulse encoder for set-point value specification Cut-Out: 93 x mm 90, 4,0 1,0 96,0 The device is supplied with all necessary terminals. Depth is increased about the connection space by at least 30 mm. Subject to technical alterations! #31051.pm

12 Technical Data HE 5130 (Option) Application: Encoder: Resolution: Pulse time: pulse generator, set-point device for process display and counter Rotation transducer with optical effect principle and electronic signal processing 0 pulses per revolution 40 msec constant, independently of the rotating speed Pulse outputs: Separately for direction of rotation 'right' [ T. ] and 'left' [ T. 3 ] Displays: Leds on the printed circuit board for function check Supply voltage: 8-5 V DC, (type 4 V), 30 ma, polarity safely [ T. 5 +, T. 4 - ] Output voltage: Follows supply voltage, short circuit proof Load: 1.5 k Ohm / 1 ma with Ub = 4 V DC see diagram U a [V] U b = 4 VDC R a = Ω U b = 4 V DC U b = 0 VDC R a = 1500 Ω R a = 5000 Ω 10 View Output Voltage t [ms] GND Out R Out L 4V Terminals 19.5 Ø Ø8.8 8 Dimensions Plugin Screw Terminals Anti Twist Hole Cut Out 8 9 all dimensions in 'mm' Submitted to technical alterations.

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

VersaMax IP Input Module

VersaMax IP Input Module Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm

More information

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS DF PROFI II CPCI Installation Instructions V1.7 27.02.2017 Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS h:\dokumente\project\5302_df_profi_ii\anwenderdoku\installation\cpci\kunbus\version_1.6\df

More information

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS DF PROFI II PCIe Installation Instructions V1.6 27.02.2017 Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS h:\dokumente\project\5302_df_profi_ii\anwenderdoku\installation\pcie\kunbus\version_1.5\df

More information

SK TU4-PBR Part number:

SK TU4-PBR Part number: SK TU4-PBR Part number: 275 281 100 PROFIBUS DP External Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

RMx621. Appendix to the operating manual

RMx621. Appendix to the operating manual Appendix to the operating manual RMx621 DP-slave module ( PROFIBUS-coupler ) from V2.01.00 Connecting the RMx621 to PROFIBUS DP via the RS485 serial interface using the external module (HMS AnyBus Communicator

More information

SCHMIDT Sensor interface PROFIBUS Instructions for use

SCHMIDT Sensor interface PROFIBUS Instructions for use SCHMIDT Sensor interface PROFIBUS Instructions for use Table of contents 1 Important information... 3 2 Intended use... 4 3 Electrical connection... 4 4 Signalizations... 7 5 Startup... 9 6 Technical data...

More information

RMx621 /FML621. Appendix to the operating manual

RMx621 /FML621. Appendix to the operating manual Appendix to the operating manual RMx621 /FML621 DP-slave module ( PROFIBUS-coupler ) from V2.01.00 Connecting the RMx621 /FML621 to PROFIBUS DP via the RS485 serial interface using the external module

More information

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013 Device manual Profibus encoder RM30xx RN30xx 706355/00 06/2013 Contents 1 Preliminary note................................................. 4 1.1 Symbols used...............................................

More information

SK CU4-PBR-C Part number:

SK CU4-PBR-C Part number: SK CU4-PBR-C Part number: 275 271 500 PROFIBUS DP Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features: DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Absolute encoder TBD/TRD with PROFIBUS-DP interface

Absolute encoder TBD/TRD with PROFIBUS-DP interface with PROFIBUS-DP interface Document no.: TRD 11868 LE Date: 15.02.2016 Singleturn and multiturn versions Contactless, wear-free sensor system according to the Hall principle High vibration and shock resistance

More information

SK TU4-CAO-C Part number:

SK TU4-CAO-C Part number: SK TU4-CAO-C Part number: 275 281 151 CANopen External Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

EL731 PROFIBUS INTERFACE

EL731 PROFIBUS INTERFACE Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/el731 EL731 PROFIBUS INTERFACE Revision 0-A-032816 Copyright 2016 Littelfuse Startco All rights reserved. Document Number: PM-1011-EN

More information

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet FACTORY AUTOMATION INSTRUCTION MANUAL WCS-Interface Module, DeviceNet WCS-DG210 Part. No. 202340 / DOCT-1305 / 11. june 2007 1 Working principle............................ 6 2 Installation and commissioning.................

More information

ATM 60/ATM 90: Multiturn Absolute Encoders extremely robust and exceptionally reliable.

ATM 60/ATM 90: Multiturn Absolute Encoders extremely robust and exceptionally reliable. ATM 60/ATM 90: Multiturn Absolute Encoders extremely robust and exceptionally reliable. With SSI- or RS 422 configuration interface, Profibus, CANopen or DeviceNet field bus technology, all current interfaces

More information

Non-communicating room controllers

Non-communicating room controllers 3 882 DESIGO RXA Non-communicating room controllers RXA29.1 For fan-coil systems The RXA29.1 room controller are used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems,

More information

Instruction Manual. Instrument Amplifier HE 017

Instruction Manual. Instrument Amplifier HE 017 Instruction Manual Instrument Amplifier HE 017 List of contents INSTRUCTION MANUAL: HE 017 Date: 20.4.99 Art.-No.: 320999 S General Safety Instructions.......................................... S 1 General

More information

DF PROFI II PC/104-Plus

DF PROFI II PC/104-Plus DF PROFI II PC/104-Plus Installation Instructions V1.4 23.09.2009 Project No.: 5302 Doc-ID.: DF PROFI II PC/104-Plus COMSOFT d:\windoc\icp\doku\hw\dfprofi ii\installation\pc104+\version_1.4\df profi ii

More information

Serial PROFIBUS Interface

Serial PROFIBUS Interface Installation Manual Serial PROFIBUS Interface Version: EN-062016-2.3 Copyright 2016 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds

More information

VersaMax IP I/O Module

VersaMax IP I/O Module Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

Rotary Measuring Technology Absolute encoders, Multiturn, Profibus-DP

Rotary Measuring Technology Absolute encoders, Multiturn, Profibus-DP Mechanical drive Safety-Lock TM High rotational speed Temperature High IP High shaft load capacity Shock/vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection Reliable

More information

AXL E PB DIO16 M12 6P

AXL E PB DIO16 M12 6P Axioline E PROFIBUS device, plastic housing, 16 freely configurable inputs or outputs, 24 V DC, M12 fast connection technology Data sheet 8437_en_03 PHOENIX CONTACT 2015-09-03 1 Description The Axioline

More information

GFK-2415A March Type of sensor connection

GFK-2415A March Type of sensor connection VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by

More information

Copyright: December 2017 Nidec Issue: E

Copyright: December 2017 Nidec Issue: E General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the optional parameters of the equipment

More information

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance red display of -9999 99999 digits installation depth: 120 mm without

More information

Rotary Measuring Technology Absolute encoders, Singleturn, Profibus-DP

Rotary Measuring Technology Absolute encoders, Singleturn, Profibus-DP Safety-Lock TM High rotational speed Temperature High IP High shaft load capacity Shock/vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection Reliable Increased ability

More information

SK CU4-CAO Part number:

SK CU4-CAO Part number: SK CU4-CAO Part number: 275 271 001 CANopen Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their technical

More information

Rotary Measuring Technology

Rotary Measuring Technology Multiturn Type 8 Profibus-DP Very compact (only 87.8 mm installation depth); Ideal for dynamic applications thanks to its non-contact multiturn stage Solid shaft or blind hollow shaft Long service life

More information

CAN 300 PRO, Communication Module

CAN 300 PRO, Communication Module 90 Communication Modules CAN 300 PRO, Communication Module Layer 2, 11 Bit and 29 Bit (CAN 2.0 A/B) on the module DIP switch for adress + baud rate Micro Memory Card for saving a project (optional) USB

More information

Manual Fiber Optic Interfaces

Manual Fiber Optic Interfaces Manual Fiber Optic Interfaces Type 81210, 81211 61210, 61211 65210, 65211 41210 Release 1.4 Subject to error and alteration 31 06/2007 by Wiesemann & Theis GmbH Subject to error and alteration: Since it

More information

Gateway 1400 Reference Manual

Gateway 1400 Reference Manual Profibus-DP Gateway 1400 Reference Manual Copyright All Rights Reserved. No part of this document may be copied, reproduced, republished, uploaded, posted, transmitted, distributed, stored in or introduced

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves switch via safe Up to 32 release circuits up

More information

Rotary Measurement Technology Absolute Encoders, Multiturn

Rotary Measurement Technology Absolute Encoders, Multiturn -40 to 80 C IP Mechanical drive Safety-LockTM High rotational speed Temperature High IP High shaft load capacity Shock/ vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection

More information

MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.

MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module. Installation INSTALLATION INSTRUCTIONS: MCD PROFIBUS MODULE Order Code: 175G9001 1. Installation 1. Remove control power and mains supply from the soft starter. 2. Attach the module to the soft starter

More information

Measuring Amplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges

Measuring Amplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges +49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Measuring mplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges Features M Bridge sensitivity

More information

Rotary Measurement Technology Absolute Encoders, Singleturn

Rotary Measurement Technology Absolute Encoders, Singleturn -40 to 80 C IP Safety-LockTM High rotational speed Temperature High IP High shaft load capacity Shock/ vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection Reliable

More information

SCH108BEX. Technical Manual. Scancon Encoders Huginsvej Hillerød Denmark Tlf Fax

SCH108BEX. Technical Manual. Scancon Encoders Huginsvej Hillerød Denmark Tlf Fax SCH108BEX Technical Manual 1 Introduction The SCH108BEX Encoder is an Ex-proof, Absolute Multiturn Encoder designed primarily for use in oilfield applications where reliability is critical, but can also

More information

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system

More information

crio PN Installation Instructions V0.2/ COMSOFT

crio PN Installation Instructions V0.2/ COMSOFT crio PN Installation Instructions V0.2/10.06.2015 COMSOFT crio PN-Installation- V0.2/10.06.2015 i:\icp\project\700391_crio_pn\anwenderdoku\installation\version_0.2\crio_pn_e.doc Revision History Version

More information

SMART RELAY SRW 01 V4.0X

SMART RELAY SRW 01 V4.0X Motors Automation Energy Transmission & Distribution Coatings SMART RELAY SRW 01 V4.0X Profibus DP Communication Manual Profibus DP Communication Manual Series: SRW 01 Firmware Version: V4.0X Language:

More information

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual Motors Automation Energy Transmission & Distribution Coatings Profibus DP SRW 01 User s Manual Profibus DP User s Manual Series: SRW 01 Firmware Version: V6.0X Language: English Document Number: 10000521541

More information

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges 0 to 5/10 V, 4 to 20 ma outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the

More information

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice. Important User Information User Manual: MCD Profibus Module Order Code: 175G9001 1. Important User Information Observe all necessary safety precautions when controlling the soft starter remotely. Alert

More information

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation

More information

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e The Sendix multiturn encoders 5862 and 5882, with SSI or RS485 interface and combined optical and magnetic sensor technology, offer a maximum resolution of 25 bits. These encoders are programmable via

More information

PROFIBUS with FBP. Achieve everything with fewer components. NEW: PDQ22-FBP The bus node with. four units ABB

PROFIBUS with FBP. Achieve everything with fewer components. NEW: PDQ22-FBP The bus node with. four units ABB PROFIBUS with FBP Achieve everything with fewer components NEW: -FBP The bus node with four units ABB FieldBusPlug: the concept ABB s communications product family comprises a range of switching and automation

More information

PAC BI-DP BIM and 8701-CA-BI Carrier

PAC BI-DP BIM and 8701-CA-BI Carrier June 2013 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier PROFIBUS DP Bus Interface Module and Carrier The 8507-BI-DP Bus Interface Module (BIM) provides the communications link between the PAC8000 series

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X 1. Use of the option modules There are two different housings with which these same plug-in units can be used namely: Calculator housing 1 (PolluTherm, PolluStat E and PolluFlow 2010) indicated by a lid

More information

SK CU4-ECT-C Part number:

SK CU4-ECT-C Part number: SK CU4-ECT-C Part number: 275 271 517 EtherCAT Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. MCD Profibus Module Instructions Important User Information Installation Instruction: MCD Profibus Module Order Code: 175G9001 1. Important User Information Observe all necessary safety precautions when

More information

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10 Model Number Features Very small housing Up to 31 bit overall resolution CANopen interface Free of wear magnetic sampling High resolution and accuracy Description This absolute rotary encoder provides

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

Extruder Controls ExtruVision S

Extruder Controls ExtruVision S Extruder Controls ExtruVision S ExtruVision S - The compact system solution for controlling, visualization, and operating extrusion systems Combination of control panel BA Touch with 5.7'' monitor and

More information

SIMOCODE 3UF Motor Management and Control Devices

SIMOCODE 3UF Motor Management and Control Devices Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient

More information

Operating Instructions

Operating Instructions Operating Instructions t i SPAN NOT USED - - 4...20mA DISPLAY t i SPAN END POINT DISPLAY Ð - 4...20mA p Safety information, Note Ex area Safety information Please read this manual carefully, and also take

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

SINGLE AND MULTI TURN ABSOLUTE ENCODER

SINGLE AND MULTI TURN ABSOLUTE ENCODER SINGLE AND MULTI TURN ABSOLUTE ENCODER MEM-Bus with Profibus protocol Operating Manual CONTENTS 1. Safety and operating instructions... 1 Encoder purpose... 1 Installation... 1 Safety... 1 2. Generals...

More information

Installation and Setup

Installation and Setup Installation and Setup 1 In This Chapter Installing the H PBC The Profibus Network Configuring the Controller Installing the H PBC Setting the Node Address Setting the Node Address Profibus DP is usually

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow

More information

ENCODER SERIES Pxx WITH PROFIBUS-DP INTERFACE

ENCODER SERIES Pxx WITH PROFIBUS-DP INTERFACE Profibus-DP Documentation ENCODER SERIES Pxx WITH PROFIBUS-DP INTERFACE PxxDocSTD R3/06/00 1 CONTENTS: 1. Mechanical installation:... 3 2. Electric installation:... 3 2.1 Connections... 3 2.2 Termination...

More information

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring

More information

PROFIBUS DP FieldBusPlug PDP21-FBP PROFIBUS DP

PROFIBUS DP FieldBusPlug PDP21-FBP PROFIBUS DP FBP FieldBusPlug V6 PROFIBUS DP FieldBusPlug PDP21-FBP PROFIBUS DP PDP21-FBP PROFIBUS DP FieldBusPlug PROFIBUS DP Fig. 1: PDP21-FBP Fig. 2: PDP21-FBP, plugged to the Universal Motor Controller UMC22-FBP

More information

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX DOCUMENT NO: TDC 0550 MANUAL - 2 1.0) INTRODUCTION. PAGE 2 1.1) ABOUT THIS MANUAL. PAGE 2 1.2) INTRODUCTION. PAGE

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

SK CU4-PNT-C Part number:

SK CU4-PNT-C Part number: SK CU4-PNT-C Part number: 275 271 515 PROFINET IO Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket echnical data sheet Damper actuator for Modbus for adjusting air dampers in ventilation and air conditioning systems in buildings orque 5 Nm Nominal voltage AC/DC 4V Communication via Modbus RU (RS-485)

More information

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00 Monitoring functions Evaluation of brush length monitoring, digital, non-floating Evaluation of brush length monitoring, digital, floating A00 A06 Non-floating brush length monitoring with use of KM01

More information

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.

More information

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is

More information

System Control Unit (SCU)

System Control Unit (SCU) ystem Control Unit (CU) Fieldbus coupler for Industrial Ethernet and Fieldbus standards Up to 28 input and 28 output variables can be assigned Easy integration in the process control system ensured through

More information

INSTRUCTION MANUAL FOR THE MC-01 CONTROL UNIT

INSTRUCTION MANUAL FOR THE MC-01 CONTROL UNIT 1 INSTRUCTION MANUAL FOR THE MC-01 CONTROL UNIT TABLE OF CONTENTS 1 INSTALLATION... 2 1.1 Mounting... 2 1.2 Mains Connection... 2 1.3 Relay Connection... 3 1.4 Pulse Input Connection... 3 1.5 4-20 ma Output

More information

Operation manual. HDOM-Profibus-V0. More options please visit;www.veikong-electric.com

Operation manual. HDOM-Profibus-V0. More options please visit;www.veikong-electric.com Operation manual HDOM-Profibus-V0 More options please visit;www.veikong-electric.com Contents 1 Introduction... 1 1.1 Product description... 1 1.2 HDOM-Profibus-V0 label... 1 1.3 Technical specifications...

More information

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module Installation and Setup 1 2 In This Chapter.... Installing the H0 PSCM The Profibus Network Configuring the Module 2 2 Installing the H0 PSCM Remove the Slot Cover The first step in installing the option

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual. INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler

More information

GS202 Encoder Switch

GS202 Encoder Switch GS202 Encoder Switch 20:2 encoder switch 20 encoder inputs (TTL / RS422 standard) Input signals A, /A, B, /B, Z, /Z on each encoder input 2 x 6 control inputs (HTL / PNP) 2 encoder outputs (TTL / RS422

More information

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information

BTF/PRF: Absolute and incremental wire draw encoders for measuring lengths up to 50 m.

BTF/PRF: Absolute and incremental wire draw encoders for measuring lengths up to 50 m. BTF/PRF: Absolute and incremental wire draw encoders for measuring lengths up to m. The combination of the wire draw mechanism and absolute or incremental encoders manufactured by SICK-STEG- MANN enables

More information

LVX Control Unit. Features:

LVX Control Unit. Features: Date 2013-02-28 Control Unit Features: Most parameters can be defined as required for your interfaces. You decide which information is output and how. Fast cycle times, just a few µs/beam. Maximum beam-count

More information

Multiturn absolute encoder

Multiturn absolute encoder Model Number Features Industrial standard housing Ø58 mm 30 Bit multiturn Galvanically isolated CAN interface DSP 406, CLASS 1 and 2 Servo or clamping flange 2 limit switches Description In addition to

More information

Non-communicating room controllers

Non-communicating room controllers 3 881 DESIO RXA on-communicating room controllers For fan-coil systems RXA20.1 RXA21.1 RXA22.1 The RXA20.1, RXA21.1 and RXA22.1 room controllers are used for temperature control in individual rooms. For

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix multiturn encoders 5868 and 5888 with CANopen or CANlift interface and optical sensor technology are the right encoders for all CANopen or CANlift applications. With a maximum resolution of

More information

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10 Model Number Features Solid shaft Up to 31 bit overall resolution CANopen interface Free of wear magnetic sampling High resolution and accuracy Highly shock / vibration and soiling resistant Sturdy construction

More information

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance. INTRODUCTION Thank you for choosing our product. The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance. This manual

More information

Technical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means

Technical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE Switch output and analog output Selectable sound lobe width Synchronization options

More information

MOVITRAC 31.. Frequency Inverter

MOVITRAC 31.. Frequency Inverter MOVITRAC 31.. Frequency Inverter PROFIBUS Fieldbus (FFP 31.. Option and Size 0/DP) Manual Edition 04/98 08/198/96 0922 6818 / 0498 Important Notes Read this User Manual carefully before you start installation

More information

SIPLUS CPU 313C-2DP. Function

SIPLUS CPU 313C-2DP. Function SIPLUS CPU 313C-2DP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LR24A-MOD Communicative rotary actuator for ball valves orque motor 5 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion of sensor signals Communication via BACnet

More information

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02 1/8 NRK16/A, NRK16-B/A, (NRK16-T /A, NRK14-T /A, NRK16-WEB/A) Control and interlock devices with pre-programmed system-specific application modules The controllers may be used as stand-alone control and

More information

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-PT100-UI(-SP)(-NC) Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection

More information

Belimo Gateway MP to Modbus RTU - UK24MOD

Belimo Gateway MP to Modbus RTU - UK24MOD Product information UK24MOD MODBUS RTU Belimo Gateway MP to Modbus RTU - UK24MOD Contents Complete overview 2 Technical data 3 Safety notes 4 Product features 4 Installation and commissioning 4 Electrical

More information

ACCESSORIES Pulse Generator V4.11 Data Sheet

ACCESSORIES Pulse Generator V4.11 Data Sheet 03.33 Quick reference: 00 pulses per revolution of measuring drum For use with TG0 to TG0, BG4 to BG100 Uni-directional Not applicable for ex-proof areas Application: Components: Description: The Pulse

More information

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit Fieldbus system PROFIBUS DP Compatible GW unit Operation Manual EX50-GPR URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8 3-507-89 Fax: +8 3-598-536

More information