CATALOG NUMBER PROJECT W2 TRACK AND COMPONENTS
|
|
- Elvin Gibson
- 5 years ago
- Views:
Transcription
1 CATALOG NUMBER TYPE PROJECT W2 TRACK AND COMPONENTS Description W2 120V or 277V Track system provides two separate 20 AMP circuits and two neutrals. Each circuit can be independently switched. Fully polarized and grounded throughout. Top portion of track is designed as a raceway adaptable to W2 suspension system. Electrical 1. W2 provides 2 track systems, rated For 120V and 277V, respectively. 2. W2 track system has 2 separate circuits: 20 amps maximum for each circuit. 3. W2 track system utilizes solid copper alloy bus bars with a rectangular cross sectional area of 7 mm W2 track system has electric feed capability through all jointers/feeders (except Power Connector and Flexible Connector) using standard ½ inch knock outs. 5. DAIL Control wiring option is available for W2 track system. Mechanical 1. W2 track is constructed of 1.85mm extruded aluminum. 2. W2 track is 36mm (wide) by 33mm (tall). 3. W2 track is available in black powder coat, white powder coat, or platinum anodized finishes. Accessories 1. W2 track system has straight and 90 connectors in the standard X, L, T, and I shapes to join track sections together in horizontal plane. 2. W2 track system has Flexible Connector to create angles from 0 to 90 in both horizontal and vertical planes 3. W2 track system has end caps to finish off sections. Fixture Interface 1. Fixtures may be installed or removed anywhere along the track. 2. Minimum fixture spacing=1ft Max weight information: From 23lbs to 67 lbs. Depend on the different support way. The drawings show the maximum permissible mechanical load by W2 tracks for luminaires or other loads in relationship to the fixation or suspension point. It includes both the weight of the track system. 3. Track fixture has safety interlocks when installd/removed. 4. Polarization is guaranteed throughout the system. Agency Listing W2 Track system UL/cUL list pending.
2 Track Sections Ordering example: 4 Model, Track Length, Finish Model For 120V WHT Track Length 4 4' 8 8' 12 12' End Cap To cover the end of a track run Model WEC For 120V WHEC To start a run Live End Connector Model WED For 120V WHED Flexible Connector To connect two track sections at any angle up to 90, for applications such as pitched ceiling. Not a feed point Model WFC For 120V WHFC "I" Connector To connect two track sections end to end to keep a straight line Model WIC For 120V WHIC "L" Connector To connect two track sections at 90 angle for a left or right turn Model WLLC/WRLC For 120V WHLLC/WHRLC
3 "T" Connector To join three track sections all at 90 Model WLTC/WRTC For 120V WHLTC/WHRTC "X" Connector To connect four track sections into a cross configuration Model WXC For 120V WHXC Power Connector To join two track sections end to end Not a feed point Model WPC For 120V WHPC Converter Allow use of W.A.C. J track heads on 120V or 277V W2 Track For low voltage lamping Model CV 2T On 120V track CVH 2T On 277V track Voltage LV Line voltage track Converter Allow use of W.A.C. J track heads on 120V or 277V W2 Track For metal halide lamping Model CV MH On 120V track CVH MH On 277V track Voltage LV Line voltage track W.A.C. Lighting reserves the right to modify the design of our products as part of the company s continuous improvement program. 4/24/2009
4 Installation Instructions: W2 Series Track Safety Instructions: 1. Read all of these instructions before installing the track system. 2. Turn off power at main switch before installing or modifying the system. 3. Do not install within six inches of any curtain or combustible materials. 4. Do not install less than 5 feet above a floor. 5. Do not install in damp or wet locations. 6. Do not install concealed, or extended through building walls. 7. Do not attempt to energize anything other than a track light fixture. 8. Do not connect a track to more than one branch circuit. Although track light systems may seem to operate acceptably, a dangerous overload of the neutral may occur and result in a risk of fire. 9. Check with a qualified electrician before wiring. 10. All installation shall be in accordance with NEC and all local codes. 11. Save these installation instructions and refer to them when additions or changes to the track configuration are made. Mounting options Mounting option A: Surface mount Mounting slots can be knocked out and are spaced every 12 inches for convenience Mount track flush to the surface and tighten screws (not included) Mounting option B: Toggle bolt mount Mounting slots can be knocked out and are spaced every 12 inches for convenience Hang track from the surface using toggle bolts (not included) Fig 1: Mounting option A (surface mount) Mounting option C: T-Bar mount Mounting slots can be knocked out and are spaced every 12 inches for convenience Fasten track to T-Bar using T-Bar clips (not included) Fig 2: Mounting option B (toggle bolt mount) Fig 3: Mounting option C (T-Bar mount) 1 /4
5 Feed options Make sure power is off before wiring. Note the polarity indicator of the track and accessories. Live end connector (WED) 1. Slide live end connector into track and tighten screw (Fig 4a) 2. Remove the cover 3. Bring feed through either the knock-out on the bottom of the connector or on the side of the connector (Fig 4b) 4. If bringing feed through the knock-out on the bottom of the connector be sure that solid end cap is installed on the side of the connector. 5. Wire per Fig 4c 6. Replace the cover Fig 4a: Live end connector track engagement Fig 4b: Live end connector feed options Fig 4c: Live end connector wiring diagram 2 /4
6 Accessory options Make sure power is off before connecting. Note the polarity indicator of the track and accessories. The I Power connector (WPC) must be placed directly between two track sections as shown in Fig 5 before tightening the screw End caps (WEC) should be inserted into the track and tightened as shown in Fig 6 Fig 5: I Power connector Other accessories should be inserted into the track and tightened as shown in Fig 7 Fig 6: End cap installation Fig 7: Accessory connection Field cutting Cut the track, insulation material, and copper busbars with one straight cut and remove any burrs that may have resulted from the cut. Cut flush Fig 8: Field cutting 3 /4
7 Track head options Track head option A: Line voltage Adapter(AD-2T-HV) for W2 line voltage track heads 1. Set circuit selector to 0 2. Set locking arm to unlock position 3. Insert adapter per Fig 9a 4. Set locking arm to lock position 5. Set circuit selector to 1 or 2 Fig 9a: Adapter to be inserted Track option B: Converter(CV-2T-LV/CV-2T- MH) for J track heads 1. Set circuit selector to 0 2. Set locking arm to unlock position 3. Insert adapter per Fig 10a 4. Set locking arm to lock position 5. Set circuit selector to 1 or 2 Locking arm Fig 9b: Inserted adapter Circuit selector Fig 10a: Converter to be inserted Locking arm Circuit selector Fig 10b: Inserted converter 4 /4
SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS
SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS - For use with CONTROLTrack System Only When installing or using this track system, basic safety precautions should always be
More informationTwo Circuit Track Power System IS24 / IS26 / IS28
Two Circuit Track Power System IS24 / IS26 / IS28 DESCRIPTION Two circuit / single neutral track is an affordable and durable solution that features easy installation. Track system is available in 4, 6,
More informationNT-2300 Series Dual Circuit Track System & Accessories
ILLUMINATING THE FUTURE...SINCE 1989 NT-2300 Series Dual Circuit Track System & Accessories Type Project Catalog No. Lamp/Wattage PRODUCT DESCRIPTION Low profile, extruded aluminum track with 20-Amp rated
More informationBPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.
BPL SERIES INSTALLATION INSTRUCTIONS Important Warning THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. This product must be installed in accordance with National Electrical
More informationSpring Test 9 due 05/11/2013
Spring Test 9 due 05/11/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. A grounding electrode is. a. a solid conductor b. a circuit conductor that
More informationA.A.G. Stucchi TRACK LIGHTING SYSTEM
A.A.G. Stucchi TRACK LIGHTING SYSTEM FEBRUARY 2015 A.A.G. Stucchi TRACK LIGHTING SYSTEM Tracks Two versions: standard recessed(r) BLACK (RAL 9005) WHITE (RAL 9010) ANODIZED (EN 5) Four Lengths (L): 1000
More informationLED Shoe Box light FEATURES AND BENEFITS: ORDERING MATRIX: LED SHOE BOX LIGHT:
ASD slim shoe box lights use up to 8% less energy than metal halide or high pressure sodium lights and put out a much nicer light. Lights up instantly, no warm-up period needed, type III distribution,
More informationNT-300 & NT-2300 Series Single & Dual Circuit Track System & Accessories
NT-300 & NT-2300 Series Single & Dual Circuit Track System & Accessories PRODUCT DESCRIPTION Low profile, extruded aluminum track with 20-Amp rated flat, solid integral conductors. Variety of connectors
More informationLED SMD FLOODLIGHT with knuckle
LED SMD Compact Floodlights are a great step forward in the lighting industry. Their energy consumption is much lower and performance is often higher than that of all other widely used types of fixtures.
More informationLED Gooseneck light FEATURES AND BENEFITS: ORDERING MATRIX: LED GOOSENECK LIGHT:
ASD LED Gooseneck Barn Lights couple rustic style with modern LED technology. This timeless classic was frequently used on barns, warehouses, and industrial complexes during the early 2th century and is
More informationNOTE: Attaches to Centro Trac, Retrac, Duplex Cable and Monopoint Systems. Evo Gobo/Framing Projector available but not shown.
Safety Instructions 1. CAUTION: Read all instructions. Do not install any Spotlight closer than six inches from any curtain or similar combustible material. Do not install this system in a damp or wet
More informationMeter Enclosure and Equipment Standards
Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable
More informationLED Shoe Box light ORDERING MATRIX: LED SHOE BOX LIGHT:
This slick and modem luminaire ASD Shoebox has been designed to handle Catalog number any environment with a beautiful slim line design. Optional photocell allows Notes for further energy saving. Save
More informationNominal. Mounting. Length foot foot RUN Nominal Lengths* Suspension Bracket 1 Studs (Factory installed) Rotating Crossbar
M125 Project: Type: Qty: Series Lamping Mounting Nominal Length Finish Voltage Options Series M125R1 Flanged M125R2 Flanged / Flush Endcaps M125 For Concrete Pour Only Lamping 1T5 2T5 1T8 2T8 1T5HO 2T5HO
More information- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV
OVERVIEW The STR9 ELV is a long run, low power, linear surface mount LED lighting system designed for exterior architectural lighting applications. This guide contains important information on planning
More informationGOLDENI. Owners Manual & Safety Instructions. English. model# GOLDi600. Copyright 2017 Smart Grow Technologies, INC All Rights Reserved
GOLDENI 600 model# GOLDi600 English Copyright 2017 Smart Grow Technologies, INC All Rights Reserved Owners Manual & Safety Instructions INTRODUCTION This User Manual is for Smart Grow Technologies (SGS):
More informationSeries Amp Pad Mount Quick Connect Input and Output Power Panels
Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.
More informationSeries Amp Quick Connect Input and Output Power Panels
Series 300 1200-1600 Amp Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury. WARNING is
More informationPMCL Series Mounts RACK/CEILING/WALL MOUNTS, UNIVERSAL CAMERA MOUNT, MONITORS
PRODUCT SPECIFICATION control site PMCL Series Mounts RACK/CEILING/WALL MOUNTS, UNIVERSAL CAMERA MOUNT, MONITORS Product Features For Use with VESA -Compliant Monitors Rack Mounts for All 200/300/400 Series
More informationRavenna TM. Fixture Options: Ordered Separately from Fixture See page 2. Mounting Options: Ordered Separately from Fixture See pages 3-5
Catalog number: and Finish Options: See page 2 ing Options: See pages 3-5 Approvals: Date: Page: 1 of 5 Specifications Lamp Housing: Die-cast low copper aluminum with die-cast cover, stainless steel fasteners,
More informationSAVE THESE INSTRUCTIONS
OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all safety information, warnings and cautions.
More informationFamily Modification Watts Dimmable CCT ASD-UHB 2 XX D XX LED UFO High Bay 100 = 100 W Dimmable 50 = 5,000 K 150 = 150 W 200 = 200 W
Our New UFO style round high bay is the latest in LED technology. Smaller, more efficient, and longer lasting, our new IP WET location rated LED UFO high bay fixture is at 1lm/w achieving desired light
More informationINSTALLATION INSTRUCTIONS
Wired Remote Controller 7 Day Programmable Ductless Systems KSACN0401AAA (High Wall Models) KSACN0501AAA (Ducted/Cassette Models) INSTALLATION INSTRUCTIONS NOTE: Read the entire instruction manual before
More informationControl Box Setup - PRSalpha
888-680-4466 ShopBotTools.com Control Box Setup - PRSalpha Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Parts List: Hooking Up a PRSalpha Gantry Tool Powering the
More informationew Downlight SM Installation Guide An EssentialWhite Product
Installation Guide ew Downlight SM An EssentialWhite Product ew Downlight SM Powercore is a low-profile, surface-mounted downlight for basic white illumination. The ew Downlight SM Powercore fixture is
More informationH704-42(H)(E), H704-42/1(H)(E)
POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (
More informationDOCKING STATION SPECIFICATIONS
ONE PERSON STATION Power Outlets Data Jack Plate Mouse Brackets Front Covers Cable Holes Cable Holes Overview: The Docking Station distributes power, data, and laptop storage to each user. It also offers
More informationInstallation Instructions MX LED Wall Wash Remodel
1 of 5 Risk of electrical shock. Disconnect power before servicing or installing luminaire. Risk of injury or damage. Luminaire will fail if not installed properly. Follow installation instructions. Risk
More informationInstallation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE
IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL
More information2700 K, 3500 K, 4000 K, Static Red, Static Green, Static Blue, Static Amber FIXTURE WATTAGE (TOTAL WATTAGE)
CES Mount ITEM Specification optics Beam Angles,,,, output Color Temperatures - total POWER CONSUMPTION (W/ft) - LUMENS - EFFICACY (lm/w) - CRI - Max Candela (CD / m 2 ) (3.5W/ft fixture meets current
More informationThe Tracking Magnet EVO Surface High-tech LED lighting system for interior architecture
Description The new Tracking Magnet 8V system is creative, flexible, reliable and precise. Accent luminaires are installed by a magnetic fastening system and a secondary mechanical fastener. The range
More informationWhat do you want to build today?
RELIABLE. RESPONSIVE. RELIABLE. RESPONSIVE. RELIABLE. RESPONSIVE. RELIABLE. RESPONSIVE. RELIABLE. RESPONSIVE. What do you want to build today? T - S L O T T E D A L U M I N U M E X T R U S I O N S V.3
More informationPlease read the Operational Manual before attempting to use this product. Operational Manual
Please read the Operational Manual before attempting to use this product. Operational Manual Super Power IR LED Illuminator & Professional Camera Housing HI7-TKHBL FEATURES 7 IR LED 7 Super Power IR LED,
More informationUNDERCARPET CABLING SYSTEM For Power and Communications
UNDERCARPET CABLING SYSTEM For Power and Communications Linking Everything Together Power, Voice, and Data December 5, 2007 Undercarpet Cabling System Overview What is Undercarpet Cabling? Primary Applications
More informationPanduit Basic Rack PDU with Local Meter
Panduit Basic Rack PDU with Local Meter User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted
More informationSECTION WIRING DEVICES
SECTION 16141 WIRING DEVICES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSYSTEM WORLD PRODUCT INFO
SYSTEM WORLD PRODUCT INFO August 208 System case.. System Case Configuration.. Width x depth x height (inches).56 x 0.62 x 3.3 inches Number of System Boxes Material Lid Type Art. No. Empty* ABS Black
More informationDECON FLUORESCENT FIXTURES TRIM TUBE 2000
DECON FLUORESCENT FIXTURES TRIM TUBE 2000 TRIM TUBE 2000 Pendant or bracket mounted luminaire with extruded aluminum body in stove enamel or epoxy, powder coated finish with black/white plastic end caps
More informationPowerFlex 750-Series Power Option Cabinets
Installation Instructions PowerFlex 750-Series Power Option Cabinets Topic Page Introduction 1 Additional Resources 2 What the Kits Contain 2 Bus-bar Selection Tables 4 Approximate Dimensions 8 Remove
More informationSECTION PANELBOARDS
SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.
More informationLED Edge-Lit Flat Panels CCT Adjustable
ASD LED Edge-Lit CCT Adjustable Panels have eliminated the need to settle on a single color temperature. These groundbreaking panels offer the ability to change color temperature (3K-5K) with the push
More informationLED Edge-Lit Flat Panels CCT Adjustable
ASD LED Edge-Lit CCT Adjustable Panels have eliminated the need to settle on a single color temperature. These groundbreaking panels offer the ability to change color temperature (3K-5K) with the push
More informationOSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE
www.osram-americas.com S90655 OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE OSRAM ReliaSys TM Outdoor LED Retrofit Kit is an alternative to high-intensity discharge (HID) lamps up to 400W (MH)
More informationZenith Series DPB. Distributed Power Busway
Zenith Series DPB Distributed Power Busway Touching all Areas of the Energy Industry GE s diverse portfolio of products and services is helping customers solve problems every day. We touch all areas of
More informationDigital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03
Digital Lighting Systems, Inc. PD26 Two Channel Dimmer and Switch Packs PROTOCOL PD26 S2 S USER'S MANUAL PD26-UM Rev. E - 02/03 Digital Lighting Systems PD26 User's Manual - Page GENERAL DESCRIPTION The
More information-Verify that supply wiring voltage matches power supply voltage by comparing it with power supply label.
WARNING! RISK OF FIRE OR ELECTRICAL SHOCK Disconnect power before installing or servicing. WARNING: Risk of fire or electrical shock. Luminaire wiring, power supply, or other electrical parts may be damaged
More informationInView Marquee Message Display
Installation Instructions InView Marquee Message Display Introduction These instructions show how to change the serial address and how to mount InView series signs with NEMA Types 4, 4X, and 12 enclosures.
More informationTOKISTAR. Light Veil Series TOKISTAR LIGHTING
TOKISTAR Light Veil Series TOKISTAR LIGHTING Light Veil TM Series Tokistar's Light Veil is a highly efficient LED wall-grazing fixture with asymmetrical light distribution. The unique multi-faceted reflectors
More informationTECHNICAL DATA SHEET DS 16S/DS 16SE. FreeSpace. Loudspeakers. Product Overview. Key Features. Product Information. Applications
Product Overview Bose FreeSpace DS 16S and FreeSpace DS 16SE loudspeakers are high-performance, surfacemount loudspeakers designed for background music and speech reproduction in a wide range of commercial
More informationPROJECT: SPECIFIER: TYPE: QTY: OUTPUT LEVEL: COLOR: LENGTH X WIDTH: MOUNTING: DIMMING/CONTROLS:
PROJECT: SPECIFIER: TYPE: QTY: Available in 5 output levels of Static White at 24 Volts RGB and RGBW available at 24 Volts Tunable White and Double Sided available Great for creating Luminous Ceilings
More informationwinline surface linear 309W wet
Project: winline surface linear 39W wet Qty: Type: Winline Surface Linear Wet - WSL39W series Linear Center Balance - LCB Linear Longest Possible - LLP Linear Same - LSL linear plan 3ADJ 3FMC Run offered
More informationBasketball Shot Clock Set LX2180 Manual
Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents
More informationSeries 062 Bus Bar Connectors
Series 062 Bus Bar Connectors Application Specification 114-2130 22 DEC 11 NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches].
More informationLED Wallpack with lenses Installation Instruction
ASD new generation of traditional wallpack with optic lenses is the premier choice for commercial and industrial lighting in a variety of settings, such as entryways, parking lots, garages, warehouses,
More informationIRONRIDGE PRODUCT CATALOG
IRONRIDGE PRODUCT CATALOG Effective March 15, 2011 Product Catalog March 15, 2011 2 What s New: 1. New Products: a. End Caps for XRS and XRL Rails Page 6 b. End Clamps I, J, K, Page 7 and updated sizing
More informationDC Outdoor Power Supply/Chargers
DC Outdoor Power Supply/Chargers Installation Guide Models Include: WayPoint3 WayPoint7-2.5A @ 12VDC or 24VDC. - 6A @ 12VDC or 24VDC. - 115/230VAC input. - 115VAC input. WayPoint5 WayPoint7V - 4A @ 12VDC
More informationTHE ARIA. LED AREA LIGHT. eran industrial. ARL SERIES
AREA LIGHT eran industrial. ARL SERIES AREA LIGHTS THE SUPERIOR ARL SERIES ARL 460 120W 100W 65W ARL 480 250W 200W 150W ARL 460 380W 300W WE CONTINUE TO BRING ADVANCED TECHNOLOGY TO THE LIGHTING INDUSTRY.
More informationPower Base AI. Power Base AI. Technical Sheets
Power Base AI Power Base AI Technical Sheets odular Electrical System System Overview Haworth s Power Base AI modular electrical system provides a flexible, reconfigurable power distribution infrastructure
More informationEnerSure Installation Guide
EnerSure Installation Guide Danger!!! The electrical components of this system may contain voltage and /or amperage sufficient to injure or kill. Installation is only to be performed by a licensed, bonded
More informationSECTION WIRING DEVICES
PART 1 - GENERAL... 1 1.1 RELATED DOCUMENTS... 1 1.2 SUMMARY... 1 1.3 DEFINITIONS... 1 1.4 REFERENCES... 2 1.5 SUBMITTALS... 2 1.6 QUALITY ASSURANCE... 2 1.7 COORDINATION... 2 PART 2 - PRODUCTS... 2 2.1
More informationM215 (M215-60) Safety
M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To
More informationAlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s)
AlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s) APPLICATION The AlphaStatus system allows one or more RSS402, RSS403,
More informationALPHA SIMBOX Small Distribution Boards
ALPHA SIMBOX Small Distribution Boards /2 Introduction /3 Introduction /4 Flush-mounting and hollow-wall distribution boards /5 Surface-mounting and hood-type distribution boards /6 Accessories /7 Dimensional
More informationMeasure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.
Product No. 99-600-91 Rev. B Page 1 of 8 MCG Surge Protection Model 160MXT Installation Instructions Important Warranty Information MCG surge protectors are designed to work at specific voltages and configurations,
More informationThe Tracking Magnet EVO Surface High-tech LED lighting system for interior architecture
Description The new Tracking Magnet 8V system is creative, flexible, reliable and precise. Accent luminaires are installed by a magnetic fastening system and a secondary mechanical fastener. The range
More informationDraper Low Voltage, Remote Control, Serial and Network Wiring Guide
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network
More information955 ebrik INSTALLATION MANUAL. Series ebrik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS LINEAR DISPLACEMENT TRANSDUCERS
Series ebrik INSTALLATION MANUAL LINEAR DISPLACEMENT TRANSDUCERS ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS Introduction The is an accurate programmable, auto-tuning, noncontact, linear
More information18W Triple 35W T4.5 G8.5 Halogen T10 100W
BLITZ 182 BLITZ BLITZ is a very versatile fixture. With a choice of one to four windows, the BLITZ can be striking even when used singly, however, the combination of choice of optic and dichroic colored
More informationElectrical Components and Equipment for General Use Self Inspection Checklist
Name of School: Optional Information Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Electrical Components and Equipment for General Use Self Inspection Checklist Guidelines:
More informationSpring Test 5 due 4/26/2013
Spring Test 5 due 4/26/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Where fixed multioutlet assemblies are employed, each feet or fraction thereof
More informationSpring Test 17 due 06/14/2013
Spring Test 17 due 06/14/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. The NEC defines cable as a cylindrical assembly composed of a conductor centered
More informationAnswer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers
Answer Modular Power Change of Height Harness Power Kits Receptical Covers NOTE: Unused modular electrical connector openings are not required to be capped. NOTE: The electrician can cut conduit and wire
More informationInstruction / Installation Sheet DataComm Electronics WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet
Instruction / Installation Sheet DataComm Electronics 45-0024-WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet DataComm Electronics, Inc. 6349 Peachtree Street Norcross, GA 30071-1725
More informationInstruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C
Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and
More informationKLIK LEDpod XL28 Patented
240 N Brookfield Rd, Suite 3 PH: 22.505.5124 FX: 22.53.52 Fixture Type: Product Code: KLIK LEDpod XL2 Patented Flat R35 R40 Description Minimalist point source LED fixture with multiple outputs for use
More informationInstallation Instructions
50ES, 50EZ, 50GL, 50GS, 50GX, 50JS, 50JX, 50JZ, 50SD, 50SZ, 50VL, 50VT, 50XP, 50XZ 601A, 602A, 602B, 604A, 604B, 604D, 607C, 701A, 702A, 702B, 704A, 704B, 704D, 707C PA1P, PA2P, PA3P, PH1P, PH2P, PH3P
More informationElectrical Management System (EMS) EMS-HW30C & EMS-HW50C
Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all
More informationInstallation Instructions
Please read all instructions before installing SPECIFICATIONS RT-100 Time Switch Programmable Countdown Voltage...120VAC, 60HZ Load (Single Pole Circuit) Incandescent or fluorescent lamp... 0 600 Watt
More informationRSS Series Wired Electronic Ballasts
RSS Series Wired s Specifications Charts RSS Series Electronic Sign Ballasts Minimum starting temperature is -20 F (-30 C). For use with T12 HO, T8 HO, and Slimline 120 Volts, 50/60Hz Per Circuit Combined
More informationLED. Sign Module. Assembly Manual
LED Sign Module Assembly Manual 6/14/2002 3:10 PM 6 2 3 3 E. S a w g ra s s R d S a ra s o ta, F L. 3 4 2 4 0 (9 4 1 )3 7 7-5 7 7 5 F A X(9 4 1 )3 7 8-4 2 2 6 www.acscontrol.com Table of Contents Table
More informationLIGHTPLANE 3.5 WET LOCATION LP3.5WL Suspended, Wall, Surface LED
LIGHTPLANE 3.5 WET LOCATION LP3.5WL Suspended, Wall, Surface LED Find additional images and information at alwusa.com/lp35wl 1. BASE MODEL LP3.5SDWL 3-1/2 suspended stem-mount direct, wet location LP3.5WIWL
More informationHigh-tech LED lighting system for interior architecture
Description Fun with magnets and light. Simultaneously graphic and subtle, the Running Magnet is flexible, precise, and as creative as you. It is track lighting redesigned and elegantly refined. Light
More informationSECTION PROJECTOR LIFTS AND MOUNTS. A. Refer to Section [ Submittal Procedures] [Insert section number and title].
(Specifier Note: The purpose of this guide specification is to assist the Specifier in correctly specifying AeroLift motorized projector lifts and their installation. The Specifier needs to edit these
More informationRegolo Perimeter System Reveal the Texture
Regolo Perimeter System Reveal the Texture ed Technology Nulite s Regolo Perimeter System is modular in design. The slender profile is ideal for highlighting textured walls in corridors, offices, lobbies
More informationHaworth Power Technical Sheets January 2018
Haworth Power Technical Sheets January 2018 Includes Accessories This page intentionally left blank. Table of Contents Desk Top Port Power Tap Cord Power Tap Conduit Enchanced Power Module Flip Top Unit
More informationWINSTA. Full Line Catalog 2008/2009
WINSTA Full Line Catalog 2008/2009 5 Contents FULL LINE CATALOG W4, Volume 1 Rail-Mounted Terminal Block Systems FULL LINE CATALOG W4 Rail-Mounted Terminal Blocks Volume 1 X-COM -SYSTEM Terminal Strips
More informationType. Project. Catalog No.
DESCRIPTION The S601 features an ultra slim low profile design giving professionals and non-professionals alike a lighting solution to a variety of applications. High output and easily concealable, the
More information1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings
Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional
More information60 Watt Portable LED Work Area Light - Waterproof - Aluminum Frame - Adjustable Light Head
60 Watt Portable LED Work Area Light - Waterproof - Aluminum Frame - Adjustable Light Head - 120-277 Part #: WAL-PM-WP60 Page: 1 Made in the USA The WAL-PM-WP60 Portable LED Work Light from Larson Electronics
More informationEnphase S-Series Microinverter and Engage Cable Safety
SAFETY Enphase S-Series Microinverter and Engage Cable Safety Important Safety Information (S280-60-LL and S230-60-LL) This document contains important instructions to use during installation of the Enphase
More informationInstallation Notes TII Model 341 Protector
Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow
More informationRGB SkyLine Rigid Border Tubing Installation Instructions
RGB SkyLine Rigid Border Tubing Installation Instructions Project Planning and Preparation(s) What you will need for parts and pieces... XXX XX Step One: Take a lineal measurement of the overall length
More informationLIGHTPLANE 3.5 WET LOCATION LP3.5RWL Recessed LED
LIGHTPLANE 3.5 WET LOCATION LP3.5RWL Recessed LED Find additional images and information at alwusa.com/lp35rwl 1. BASE MODEL LP3.5RWL 1 3-1/2 recessed direct, wet location 1 Requires an already finished
More informationM250 (M LL) Safety
M250 SAFETY M250 (M250-60-2LL) Safety Important Safety Information This document contains important instructions to use during installation of the Enphase M250 Microinverter. To reduce the risk of electrical
More information120 lm HIGH LUMINOUS EFFICIENCY
ASD ED Wall Packs feature leading-edge optics that increase light output and reduce shadows to create safe, brightly-lit outdoor environments in parking garages and entrances, schools, hospitals, hotels,
More informationHigh-tech LED lighting system for interior architecture
Description The Tracking Magnet system is creative, flexible, reliable and precise. Accent fixtures can be rapidly exchanged and repositioned without tools using the magic of magnets. A variety of accent
More informationTECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2
document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com
More information1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM
1993 SPECIFICATIONS CSJ 1685-05-068, ETC. & 1685-02-042 1.0 DESCRIPTION SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM THIS ITEM DESCRIBES THE OPERATION AND INSTALLATION OF AN ARTERIAL
More informationAB-2D AB-2D SPEAKER A,B OR A+B SELECTOR INSTALLATION & OPERATION GUIDE
M O D E L AB-2D AB-2D SPEAKER A,B OR A+B SELECTOR INSTALLATION & OPERATION GUIDE AB-2D Speaker/Amplifier Selector TABLE OF CONTENTS Introduction 1 Features and Benefits 1 Installation Considerations 3
More informationPanduit Basic Rack PDU
Panduit Basic Rack PDU User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted by any
More information