S5-115U. Application
|
|
- Cordelia Harrington
- 6 years ago
- Views:
Transcription
1 S5-115U
2 S5-115U Design Central configuration Distributed configuration Note General technical specifications
3 S5-115U Principle of operation Program memory Processor Programming
4 S5-115U Cyclic program execution Interrupt-driven program execution Time-controlled program execution Time interrupt-controlled program execution
5 S5-115U Communication SINEC L1 local area network Features PROFIBUS local area network Industrial Ethernet local area network
6 S5-115U Quality assurance procedures Product planning Product development and production Product operation Availability Safety Installation guidelines
7 S5-115H Design
8 S5-115H Design Normal fault tolerance Enhanced fault tolerance
9 S5-115H Design Maximum fault tolerance Mixed configuration
10 S5-115H Design Redundancy of IPs and CPs
11 S5-115H Principle of operation Data interchange and fault handling Synchronization
12 S5-115H Principle of operation Self-test Programming, parameter assignment Programming Parameter assignment
13 S5-115H Subracks for the S5-115H Interface modules for the S5-115H CPU for the S5-115H I/O modules for the S5-115H
14 S5-115F Requirement classes
15 S5-115F Design Safety-related areas Non-safety-related areas
16 S5-115F Principle of operation Comparison of inputs Comparison of outputs Comparison of further data
17 S5-115F Principle of operation Self-test during initialization Self-test in cyclic operation Programmming and parameter assignment Programming Note Parameter assignment
18 S5-115F Communication Features
19 S5-115F Communication Possible configurations Operator-control and process monitoring
20 S5-115F Subracks for the S5-115F Interfaces modules for the S5-115F CPU for the S5-115F I/O modules for the S5-115F Note
21 CPU 941, CPU 942, CPU 943 and CPU 944 central processing units for the S5-115U Design Functions Program execution Monitoring Software protection for RAM operation Scan time measurement
22 CPU 941, CPU 942, CPU 943 and CPU 944 central processing units for the S5-115U Functions Clock Integral function blocks Integral organization blocks µ Restart modes COM DB1 parameterization software For technical specifications Ordering data CPU 941 CPU 942 6ES UB11 6ES UB , 3964R communications protocol CPU 943 6ES UB11 6ES UB memory submodules CPU 944 S5-115U manual S5-115U quick reference guide 6ES UB11 6ES UB21 6ES UF13 6ES UF23 6ES UF33 6ES UF43 6ES UF53 6ES LA11 6ES LA21 6ES LA31 6ES LA41 6ES LA51 6ES BB21 6ES LA15 6ES LA21 6ES LA41 6ES LA61 6ES LA71 Standard function blocks Programming software COM DB1 parameter assignment software COM REG S5-115U parameter assignment software 6ES LC31 6ES LC41 6ES LD11 6ES LD21 6ES LD31
23 CPU 945 central processing unit for the S5-115U Design Functions Program execution Monitoring Process I/O image transfer Changing the operating system Integral function blocks For technical specifications Ordering data CPU 945 S5-115U quick reference guide 6ES UA13 6ES UA23 6ES LB11 6ES LB21 6ES LB31 Interface modules Programming adapter Parameter assignment software 6ES LA12 6ES LA22 6ES LA42 6ES LA52 6ES LA62 6ES MC11 Memory card 6ES KG11 6ES KH21 6ES KJ11 Manual for the S5-115U with CPU 945 6ES UF11 6ES UF21 6ES UF31 6ES UF51
24 CPU 941, CPU 942, CPU 943, CPU 944 and CPU 945 central processing units for the S5-115U Technical specifications CPU CPU 945 CPU 944 CPU 943 CPU 942 CPU 941 µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ µ
25 CPU 941, CPU 942, CPU 943, CPU 944 and CPU 945 central processing units for the S5-115U Technical specifications CPU CPU 945 CPU 944 CPU 943 CPU 942 CPU 941
26 CPU 942H central processing unit for the S5-115H Principle of operation Technical specifications Ordering data CPU 942H 6ES UH memory submodule COM 115H parameterization software Manual 6ES UH11 6ES UH21 6ES UH31 6ES UH41 6ES UH51
27 CPU 942F central processing unit for the S5-115F Principle of operation Technical specifications µ µ Ordering data CPU 942F 375 memory submodule 6ES UF15 COM 115F parameterization software S5-115F manual 6ES UF15 6ES UF25 6ES UF35 6ES UF55
28 Overview Digital input and output modules Digital input and output modules Input modules Output modules Input/output modules
29 Digital input modules Design Principle of operation Enable input Interrupt processing Note Technical specifications Digital input module Number of inputs Input voltage 24 V DC 24 V DC 24/48 V UC 48/60 V UC 24 V DC
30 Digital input modules Technical specifications Digital input module Digital input module Number of inputs Input voltage 115 V UC 115 V UC 115 V UC 230 V UC 230 V UC 230 V UC
31 Digital input modules Ordering data digital input module digital input module digital input module digital input module digital input module for NAMUR sensor digital input module digital input module 6ES LA11 6ES LA12 6ES LA11 6ES LA11 6ES UA12 6ES LA12 6ES LA11 6ES LB11 6ES LC digital input module 490 front connector 497 front connector Adapter casing 6ES LA11 6ES LB11 6ES LC11 6ES LB11 6ES LB21 6ES LA11 6ES LA21 6ES LC11 6ES UA12 6ES UB31
32 Digital input modules Connection diagrams Siemens AG 2007
33 Digital input modules Connection diagrams
34 Digital output modules Design Principle of operation Short-circuit protection Parallel connection of outputs Note
35 Digital output modules Technical specifications Digital output module 6ES LA12 6ES LA11 6ES LA21 6ES LA11 6ES UA12 Number of outputs Supply voltage Output current V DC 0.5 A V DC 0.5 A V DC 0.5 A 16 24/48/60 V DC 0.5 A
36 Digital output modules Technical specifications Digital output module 6ES LA12 6ES LB11 6ES LA11 6ES LA11 6ES LB11 6ES LA11 Number of outputs Supply voltage Output current V DC 2 A 8 24 V DC 2 A 16 48/115 V AC 2 A/group /230 V AC 1 A 8 115/230 V AC 2 A 32 5/12/24 V DC 100 ma µ
37 Digital output modules Technical specifications Digital output module 6ES LA11 1) 6ES LB11 6ES LC11 Number of outputs Continuous current Supply voltage A 8 5 A 16 5 A Ordering data digital output module digital output module digital output module digital output module digital output module digital output module digital output module digital output module 6ES LA12 6ES LA12 6ES LA21 6ES LA11 6ES UA12 6ES LA12 6ES LB11 6ES LA11 6ES LA11 6ES LB digital output module digital output module 490 front connector 6ES LA11 6ES LA11 6ES LB11 6ES LC11 6ES LB11 6ES LB21 6ES LA11 6ES LA21 6ES LC11
38 Digital output modules Connection diagrams Siemens AG 2007
39 Digital output modules Connection diagrams Siemens AG 2007
40 Digital input/output modules Design Principle of operation Interrupt processing Note Technical specifications Digital input/output module 6ES LA11 6ES LF11 6ES LF21 6ES LF31 6ES LA11 Number of inputs Input voltage 16, 24 V DC 16, 24 V DC 16, 24 V DC 8, 24 V DC V DC
41 Digital input/output modules Technical specifications Digital input/output module 6ES LA11 6ES LF11 6ES LF21 6ES LF31 6ES LA11 Number of outputs Supply voltage Output current 16, 24 V DC 0.5 A 16, 24 V DC 0.5 A 16, 24 V DC 0.5 A 8, 24 V DC 2.5 A V DC 1.5 A Ordering data digital input/output module 6ES LA11 6ES LF11 6ES LF21 6ES LF digital input/output module 490 front connector 6ES LA11 6ES LB21 6ES LA11 6ES LA21 6ES LC11
42 Digital input/output modules Connection diagrams
43 Analog input modules Design Principle of operation Note Technical specifications Analog input module 6ES LA13 6ES LA13 6ES U.12 Number of inputs Input ranges ± 50 mv; ± 500 mv; Pt 100; ± 1 V; ± 5 V; ± 10 V; ± 20 ma; ma Ω Ω; Ω; Ω Ω; Ω; Ω Ω; V, V, ma ma Ω Ω; Ω Ω
44 Analog input modules Technical specifications Analog input module 6ES LA13 6ES LA13 6ES U.12 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ±
45 Analog input modules Technical specifications Analog input module Number of inputs Input ranges ± 6ES LA ma; ma; ± 20 ma V; V; V; V; V ± 1.25 V; ± 2.5 V; ± 5 V; ± 10 V Ω Ω µ ± ± ± ± ± ±
46 Analog input modules Ordering data analog input module analog input module 498 measuring range module ± ± ± ± ± ± analog input module 6ES LA13 6ES LA13 6ES AA11 6ES AA21 6ES AA61 6ES AA31 6ES AA41 6ES AA51 6ES AA71 6ES UA12 6ES UB analog input module 490 front connector 497 front connector K front connector Adapter casing 6ES LA11 6ES LB21 6ES LA11 6ES LA21 6ES LC11 6ES UA12 6ES UB31 6XX XX3 081 Connection diagrams
47 Analog input modules Connection diagrams
48 Analog output modules Design Principle of operation Note Technical specifications Analog output module 6ES L.13 Analog output module 6ES L.13 Number of outputs 8 Output ranges ±10 V; ma ±10 V V; ma Ω Ω ± ± ±
49 Analog output modules Ordering data 470-7LA analog output module ± 6ES LA LB analog output module ± 470-LC analog output module 6ES LB13 6ES LC front connector 6ES LB21 6ES LA11 6ES LA21 6ES LC11 Connection diagrams
50 Intelligent I/O modules Overview For further information, see Section 4.
51 Overview Overview Special tasks Supplementary equipment Simulation connectors Design Ordering data Simulation connectors 6ES SA11 6ES SA21
52
53 Communications modules and bus systems Overview Point-to-point connection Bus systems For further information, selection and ordering data, see Section 4.
54 CP 523 communications processor for the S5-115F Design Principle of operation Interfacing Message printout
55 CR 700-0LA subrack for S5-115U central controllers Design Ordering data CR 700-0LA subrack 6ES LA12
56 CR 700-0LB subrack for S5-115U central controllers Design Ordering data CR 700-0LB subrack 6ES LB11
57 CR subrack for S5-115U central controllers Design Ordering data CR subrack 6ES LA12
58 CR subrack for S5-115U central controllers Design Ordering data CR subrack 6ES LA12
59 CR subrack for S5-115U central controllers Design Ordering data CR subrack 6ES LA12
60 ER subrack for S5-115U expansion units Design Ordering data ER subrack 6ES LA11
61 ER subrack for S5-115U expansion units Design Ordering data ER subrack 6ES LA12
62 ER subrack for S5-115U expansion units Design Ordering data ER subrack 6ES LA12
63 ER subrack for S5-115U expansion units Design Ordering data ER subrack 6ES LA13
64 CR 700-0LB subrack for S5-115H central controllers Design Ordering data CR 700-0LB subrack 6ES LB11
65 CR subrack for S5-115H central controllers Design Ordering data CR subrack 6ES LA12
66 CR 700-2F subrack for S5-115H central controllers Design Ordering data CR 700-2F subrack 6ES LA22
67 CR subrack for S5-115H central controllers Design Ordering data CR subrack 6ES LA12
68 ER 701-3LH subrack for I/O modules in switched configuration with S5-115H Design Note on single-sided and two-channel configuration: Ordering data ER 701-3LH subrack 6ES LH11
69 CR 700-0LB subrack for S5-115F central controllers Design Ordering data CR 700-0LB subrack 6ES LB11
70 CR 700-2F subrack for S5-115F central controllers Design Ordering data CR 700-2F subrack 6ES LA22
71 ER subracks for S5-115F expansion units Design Ordering data ER subrack 6ES LA12
72 ER subrack for S5-115F expansion units Design Ordering data ER subrack 6ES LA12
73 ER subrack for S5-115F expansion units Design Ordering data ER subrack 6ES LA13
74 Fan subassembly Design Technical specifications For long subracks For short subracks Ordering data Fan subassembly Mounting accessories 6ES H11 6ES H 21 6ES G 11 Replacement fan 6ES NA11 Dust filter (filter mat) 6ES J 11 A B
75 PS 951 power supply modules for the S5-115U/H Design Technical specifications Power supply module 6ES LB21 6ES LD21 6ES NB21 6ES ND51 6ES ND41 Supply voltage Output current 230/120 V AC ± 3 A 3 A 230/120 V AC ± 7 A 15 A 24 V DC ± 3 A 3 A 24 V DC ± 7 A 15 A 24 V DC ± 7 A 15 A
76 PS 951 power supply modules for the S5-115U/H Ordering data PS 951 power supply module 6ES LB21 6ES LD21 6ES NB21 6ES ND51 6ES ND41 Backup battery, 6EW AA 6ES AE11
77 PS 951 power supply module for the S5-115F Design Technical specifications Supply voltage 24 V DC Output current Current consumption ± Ordering data PS 951 power supply module for S5-115F 6ES ND41 Backup battery 6ES AE11
78 Interface modules Overview IM 305 IM 306 IM 301 IM 304 IM 304 IM 305 IM 306 IM 310 IM 307 IM 308 IM 314 IM 314R IM 317 IM 307 IM IM IM 308-B IM 318-B/C
79 IM 305 and IM 306 interface modules; centralized configuration with S5-115U Design IM 305 interface module IM 306 interface module
80 IM 305 and IM 306 interface modules; centralized configuration with S5-115U Technical specifications IM 305 interface module IM 306 interface module Ordering data IM 305 interface module IM 306 interface module 6ES LA11 6ES LB11 6ES LA connecting cable 6ES AF00 6ES BB20 6ES BB50 6ES BC50
81 IM 304 and IM 314 interface modules; distributed configuration up to 600 m with S5-115U Design Connection of other programmable controllers
82 IM 304 and IM 314 interface modules; distributed configuration up to 600 m (1968 ft) with S5-115U Technical specifications Ordering data IM 304 interface module IM 314 interface module 6ES UB11 6ES UA11 Terminator Adapter casing 721 connecting cable 6ES AA11 6ES BB00 6ES BB60 6ES BC00 6ES BF00 6ES CB00 6ES CF00 6ES BC50 6ES BD20 6ES BJ00 6ES CB20 6ES CB60 6ES CC00 6ES CC50 6ES CD20 6ES CE00 6ES CG30 6ES CJ00 6ES DB00 6ES DF00
83
84 IM 308 and IM 318 interface modules; distributed configuration up to 3000 m with S5-115U Design Cables Ω Ω Ω
85 IM 308 and IM 318 interface modules; distributed configuration up to 3000 m with S5-115U Design Technical specifications Ordering data IM 308 interface module 6ES UA12 IM interface module 6ES MA memory submodule (EPROM) IM interface module 6ES AA11 6ES UA11 Adapter casing IM 308/IM 318 manual 6ES DP11 6ES DP21 6ES DP31
86 IM 308-C interface module; PROFIBUS-DP interface for the S5-115U/H (up to S5-155U/H) Design Principle of operation Configuring Technical specifications Ordering data IM 308-C interface module 6ES UC11 Memory card 6ES FH21 6ES KK21
87 IM 304 and IM 324R interface modules, for interfacing the S5-115H central controllers Design Principle of operation Technical specifications Ordering data IM 304 interface module IM 324R interface module 6ES UB11 6ES UR11 Adapter casing 721 connecting cable
88 IM 304 and IM 314R interface modules, for distributed configuration of I/O modules at S5-115H Design Technical specifications Ordering data IM 304 interface module IM 314R interface module 6ES UB11 6ES UR11 Terminator for the IM 314R Adapter casing 721 connecting cable 6ES HA11
89 IM 304 and IM 324 interface modules; for interfacing the S5-115F central controllers Design Technical specifications Ordering data IM 304 interface module 6ES UB11 Adapter casing 721 connecting cable 6ES LB11 IM 324 interface module 6ES UA12
90 IM 306 interface module; for centralized configuration of I/O modules at S5-115F Design Note Principle of operation Ordering data IM 306 interface module 6ES LA connecting cable 6ES AF00 6ES BB20 6ES BB50 6ES BC50
91 IM 304 and IM 314 interface modules for distributed configuration of I/O modules at S5-115F Design Principle of operation Ordering data IM 304 interface module IM 314 interface module 6ES UB11 6ES UA11 Terminator for IM 314 interface module Adapter casing 721 connecting cable 6ES AA11
92 Front connector Design Technical specifications Front connector 6ES LB11 6ES LB21 6ES LA.. 6ES LC11 6ES Ordering data 490 front connector 6ES LB11 6ES LB21 K front connector 6XX bridge jumper 497 front connector 6ES LA11 6ES LA21 6ES LC11 6ES LA 11 Crimp contacts Crimping tool Extraction tool Labelling strips 6XX XX XX ES MA11 6ES LA11
93 Adapter casings Technical specifications Adapter casing 6ES LB11 6ES LD11 6ES LC11 Ordering data Adapter casing 6ES LB11 6ES LD11 6ES LC11
94 Text Display TD 390 Design Technical specifications Ordering data TD 390 text display 6ES UA11
S5-115U. Application
S5-115U Application S5-115U Design Central configuration Distributed configuration Note General technical specifications S5-115U Principle of operation Program memory Processor Programming S5-115U Cyclic
More informationS5-135U, S5-155U. Application
S5-135U, S5-155U Application S5-135U, S5-155U Application Design S5-135U, S5-155U Design S5-135U, S5-155U Design Central configuration Distributed configuration S5-135U, S5-155U Design Housing Power supply
More informationCPU 412H. Function. Parameterizable properties
CPU 412H Function Block protection: In addition to the keylock switch, a password concept protects the user program from unauthorized access. Integrated HMI services: In the case of HMI devices, the user
More informationSIMATIC S plus TIA Portal
Product range overview SIMATIC S7-1500 plus TIA Portal Power + Efficiency The ultimate plus in automation Intuitive, efficient, proven TIA Portal redefines engineering Answers for industry. Your plus of
More informationBẢNG GIÁ PLC SIEMENS S7-300 Áp dụng từ 01/01/ Giá chưa bao gồm thuế VAT
BẢNG GIÁ PLC SIEMENS S7-300 Áp dụng từ 01/01/2011 - Giá chưa bao gồm thuế VAT NO I SIMATIC S7-300 Central Processing Unit 1 6ES7312-1AE13-0AB0 SIMATIC S7-300, CPU 312 CPU WITH MPI INTERFACE, INTEGRATED
More informationLaboratory automation
Siemens AG 2008 Laboratory automation /2 SIMATIC PCS 7 LAB: Compact control system for the laboratory automation Siemens ST PCS 7.1 Update October 2008 Laboratory automation Siemens AG 2008 Overview PCS
More informationSIMATIC. Digital Input Module SM DI, DC24V - Sinking/Sourcing. Product information. Product Information
SIMATIC Digital Input Module Product information 1 SIMATIC Digital Input Module Product Information This documentation is part of the documentation package with the order number: S7-300 Automation System:
More informationSIMATIC ET 200SP Product information on documentation of the ET 200SP distributed I/O system Product Information
SIMATIC ET 200SP Product information on documentation of the ET 200SP distributed I/O system Product Information General amendments to the documentation Contents This product information includes amendments
More informationDETAIL SPECIFICATION SHEET
INCH-POUND MIL-DTL-55302/128D 18 April 2013 SUPERSEDING MIL-DTL-55302/128D 4 June 2004 DETAIL SPECIFICATION SHEET CONNECTORS, PRINTED CIRCUIT SUBASSEMBLY AND ACCESSORIES: RECEPTACLE, DOUBLE ROW, 4 THROUGH
More informationhttps://support.industry.siemens.com/cs/ww/en/view/
Support Packages for TIA Portal V14 February 2018 https://support.industry.siemens.com/cs/ww/en/view/72341852 Siemens Industry Online Support This entry is from the Siemens Industry Online Support. The
More informationSupplier s declaration of conformity
Supplier s declaration of conformity As required by the following Notices: > Radiocommunications (Compliance Labelling - Devices) Notice 2014 made under section 182 of the Radiocommunications Act 1992;
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG LOW VOLTAGE SIEMENSSTRASSE 10 93055 REGENSBURG, GERMANY This is to certify that representative samples of Motor Controllers, Manual See following pages for list of models Have been
More informationContinuous level measurement Ultrasonic controllers
Siemens AG 0 Overview is a complete ultrasonic level controller for monitoring and control of water distribution and wastewater collection systems, with energy-saving algorithms. Benefits Monitoring and
More informationProduct Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.
Product Information Mixed Configuration ET 200SP / ET 200AL SIMATIC ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL Product Information Preface Application planning 1 Mounting 2 Connection
More information22ND CENTURY_J1.xls Government Site Hourly Rate
Escalation rate 000 AA0 Administrative Assistant Level I 000 AA0 Administrative Assistant Level II 000 AB0 Application Engineer Level I 000 AB0 Application Engineer Level II 000 AC0 Application Programmer
More informationProduct Information on the Manual
Edition 12.2004 S7-300 Programmable Controller; Module Specifications, as of Edition 02/2004 (A5E00105505) ET 200M Distributed I/O Device Signal Modules for Process Automation, as of Edition 10/2004 (A5E00085262)
More informationMeter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)
Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M9813380120-A) 1.- BASIC INSTRUCTIONS 1.1.- Checks on receipt. This manual assists in the installation and handling of
More informationSIMATIC S5. S5-100U Programmable Controller. System Manual CPU 100/102/103. EWA 4NEB b. Edition 04
SIMATIC S5 S5-100U Programmable Controller System Manual CPU 100/102/103 EWA 4NEB 812 6120-02b Edition 04 STEP SINEC and SIMATIC are registered trademarks of Siemens AG. LINESTRA is a registered trademark
More informationCentral processing units CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226
Overview CPU 226 The high-performance package for complex technical tasks With additional PPI port for more flexibility and communication options With 40 inputs/outputs on board Expansion capability for
More informationAppendix 5-1: Attachment J.1 Pricing Table -1: IMS Ceiling Loaded Rates at Contractor Site
Appendix 5-1: Attachment J.1 Pricing Table -1: IMS Ceiling Loaded Rates at Contractor Site Escalation rate 4.6% 4.6% 4.6% 4.6% 4.6% 4.6% 4.6% 4.6% 4.6% 0001 AA01 Administrative Assistant Level I $51.00
More informationProduct Information on the Manual
Product Information on the Manual Edition 04.2003 S7-300 Module Specifications, Edition 11/2002, (A5E00105505-02) Introduction The S7-300 product family has been enhanced and improved. This document contains
More informationLevel instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI
SITRANS LUC00 Siemens AG 009 Overview SITRANS LUC00 is a complete ultrasonic level controller for monitoring and control of water distribution and wastewater collection systems, with energy-saving algorithms.
More informationBẢNG GIÁ PLC SIEMENS S7-200 Áp dụng từ 01/11/ Giá chưa bao gồm thuế VAT
BẢNG GIÁ PLC SIEMENS S7-200 Áp dụng từ 01/11/2011 - Giá chưa bao gồm thuế VAT NO A I SIMATIC S7-200 CLASSIC (GERMANY ORIGIN) - SIMATIC S7-200 (XUẤT XỨ ĐỨC) SIMATIC S7-200 Central Processing Unit 1 6ES7211-0AA23-0XB0
More informationSIMATIC S Central processing units
SIMATIC S7-1500 Siemens AG 2013 Overview CPU 1511-1 PN PROFINET IO Controller for operating distributed I/O on PROFINET PROFINET I-Device for connecting the CPU as an intelligent PROFINET device under
More informationS7-400, M7-400 Programmable Controllers
This Supplement contains additional information about the products. It is a separate component and should be considered more up-to-date than the information in the manuals and catalogs if uncertainties
More informationSPAREPARTSCATALOG: CONNECTORS SPARE CONNECTORS KTM ART.-NR.: 3CM EN
SPAREPARTSCATALOG: CONNECTORS ART.-NR.: 3CM3208201EN CONTENT SPARE CONNECTORS AA-AN SPARE CONNECTORS AO-BC SPARE CONNECTORS BD-BQ SPARE CONNECTORS BR-CD 3 4 5 6 SPARE CONNECTORS CE-CR SPARE CONNECTORS
More informationA B
ET 200U Distributed I/O Station Manual System Overview Technical Description Mechanical and Electrical Configuration ET 200U(DP Siemens): Address Assignment, Starting Up, Diagnosing Faults ET 200U(DP Standard):
More informationUse with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2
Use with 0 to 70 C ambient temperature SIMATIC Preface 1 Product combination 2 Product family 3 Process Control System PCS 7 Use with 0 to 70 C ambient temperature System Manual 02/2015 A5E35458345-AA
More informationSIMADYN D Control System
SIMADYN D Control System /2 Introduction /4 Subracks / SR6 Subracks /6 SR12 Subracks /8 SR24 Subracks /10 SR 8x Slot Cover /11 CPU Modules /12 PM CPU Module /13 PM6 CPU Module /14 Accessories for CPU Modules
More informationSIMATIC S7-200 PRICE LIST
BẢNG GIÁ PLC SIEMENS S7-200 SIMATIC S7-200 PRICE LIST Part number SIMATIC S7-200 CLASSIC (GERMANY ORIGIN) SIMATIC S7-200 Central Processing Unit 6ES7211-0AA23-0XB0 6ES7211-0BA23-0XB0 6ES7212-1AB23-0XB0
More informationSPARE CONNECTORS KTM 2014
SPAREPARTSCATALOG: // ENGINE ART.-NR.: 3208201EN CONTENT CONNECTORS FOR WIRING HARNESS AA-AN CONNECTORS FOR WIRING HARNESS AO-BC CONNECTORS FOR WIRING HARNESS BD-BQ CONNECTORS FOR WIRING HARNESS BR-CD
More informationProduct type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory
Data sheet SIMATIC S7-400H, CPU 414-5H, CENTRAL UNIT FOR S7-400H AND S7-400F/FH, 5 INTERFACES: 1X MPI/DP, 1X DP, 1X PN AND 2 FOR SYNC MODULES 4 MB MEMORY (2 MB DATA/2 MB CODE) Product type designation
More informationSIMATIC. FM 356 Application Function Module, Installation and Startup. Preface, Contents. User Information. Product Overview
Preface, Contents User Information SIMATIC FM 356 Application Function Module, Installation and Startup Manual Product Overview 1 Designing the Mechanical Configuration 2 Addressing the M7-300 Modules
More information4. Specifications and Additional Information
4. Specifications and Additional Information AGX52004-1.0 8B/10B Code This section provides information about the data and control codes for Arria GX devices. Code Notation The 8B/10B data and control
More informationVIPA System 300S - The High-Speed control system
Software HMI System 500S System 400V System 300V System 300S System 200V System 100V High-speed control system programmable with STEP 7 from Siemens Features VIPA System 300S: Programmable with Step 7
More informationSIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.
Product data sheet SIMATIC S7-400, CPU 414-3 768 KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.IF FOR IFM CiR - Configuration in RUN CiR synchronization
More informationProduct Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V
Product Information SIMATIC S7-300 Digital Output Module SM 322; DO 16 UC24/48 V X 2 as of Version 3 4 New Digital Output Module Available The S7-300 Digital Output Module SM 322; DO 16 UC24/48 V has been
More informationSupply voltage. Input current. Power loss. Memory. Battery. CPU processing times
Data sheet SIMATIC S7-400H, CPU 417H CENTRAL UNIT FOR S7-400H 4 INTERFACES: 1 MPI/DP, 1 DP A. 2 FOR SYNC MODULES 4MB MEMORY (2MB CODE/2MB DATA) Supply voltage Rated value (DC) 24 V DC Input current from
More informationProduct type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory
Data sheet SIMATIC S7-400, CPU 417-4 CENTRAL PROCESSING UNIT WITH: 30 MB WORKING MEMORY, (15 MB CODE; 15 MB DATA) 1. INTERFACE MPI 12 MBIT/S, 2. INTERFACE PROFIBUS DP, 3./4. IF IFM MODULES PLUGGABLE Product
More informationCPU 410-5H Process Automation SIMATIC. PCS 7 process control system CPU 410-5H Process Automation. Preface 1. Introduction to CPU 410-5H
SIMATIC PCS 7 process control system System Manual Preface 1 Introduction to CPU 410-5H 2 Structure of the CPU 410-5H 3 I/O configuration variants 4 PROFIBUS DP 5 PROFINET IO 6 Operator controls and operating
More informationGeneral information. Supply voltage
Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1
More informationAC 800M for Compact Product Suite Outline of all modules
DATA SHEET AC 800M for Compact Product Suite Outline of all AC 800M is a family of rail-mounted, consisting of CPU:s, communication, power supply and various accessories. There are several CPU to choose
More informationS7-400, M7-400 Programmable Controllers
This Supplement contains additional information about the products. It is a separate component and should be considered more up-to-date than the information in the manuals and catalogs if uncertainties
More informationSiemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY
Issued to: Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that Auxiliary Devices representative samples of 3UF70 followed by 0 or 1 followed by 0
More information1. CP430, CP470, CP474, CP770 and CP774
1. CP430, CP470, CP474, CP770 and CP774 1.1 Order data CPUs CP430, CP470, CP474, CP770 and CP774 CP430, CP470, CP770 CP474, CP774 Model number 7CP430.60-1 7CP470.60-2 7CP474.60-2 7CP770.60-1 7CP774.60-1
More informationProduct information on the documentation of the. ET 200SP distributed I/O system SIMATIC ET 200SP. ET 200SP distributed I/O system.
Product information on the documentation of the ET 200SP distributed I/O system SIMATIC Preface Overview of the ET 200SP 1 General additions to the documentation 2 ET 200SP Product information on the documentation
More informationvideo matrix switching system up to 255 inputs & 64 outputs
video matrix switching system up to 255 inputs & 64 outputs SIMATRIX SYS Input terminals with selection assignment Freely- programmable picture cycle Selection of group (max. 4 cameras) On-screen text
More informationET 200S Motor Starters and Safety Motor Starters
Overview for Standard motor starters Control kit The control kit for the Standard motor starter provides the possibility of testing the motor during start-up or service by actuating the motor starter protector.
More informationSIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.
SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Power module PM-E DC24..48V/AC24..230V (6ES7138-4CB11-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 04/2007
More informationIEC Contactors. Auxiliary Contact Blocks GENERAL
IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount
More informationThe 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.
The 12.5kW power shelf accepts 3-phase input power and provides stable DC output power (1000A at 12.5VDC). The OCP 21-inch power shelf includes a total of 5+5 high-power, hot-swappable PSUs in redundant
More informationProduct type designation. General information. Supply voltage. Input current
Data sheet SIMATIC S7-300, CPU 312C COMPACT CPU WITH MPI, 10 DI/6 DO, 2 FAST COUNTERS (10 KHZ), INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING MEMORY, FRONT CONNECTOR (1 X 40PIN) AND MICRO MEMORY CARD
More informationDBK24. Isolated Digital Output Chassis. Overview
DBK24 Isolated Digital Output Chassis Overview 1 Power Requirements 2 Hardware Setup 2 Card Connection 2 Card Configuration 3 DaqBook and DaqBoard Connection 4 DaqBoard/2000 Series Board Connection 5 DaqBook
More informationLimit Switches and Safety
Industrial Controls Product Catalog 217 Section contents 3SE International (IEC) 3SE5 General data Overview /4 - /9 3SE5 plastic enclosures Plastic, 31 mm Plastic, 5 mm 3SE5, selection and ordering data,
More informationSIMATIC PCS 7 V6.1 + SP1. Redundancy and fault tolerance with PCS 7. Redundancy and fault tolerance with PCS 7. Topics
SIMATIC PCS 7 V6.1 + SP1 Redundancy and fault tolerance with PCS 7 SIMATIC PCS 7 V6.1 + SP1 Siemens AG Slide 1 Introduction and Overview Process control systems are responsible for controlling, monitoring
More informationIntrinsic Safety Control Drawing
s Intrinsic Safety Control Drawing system in total PLC PC Not hazardous area PROFIBUS DP Associated Apparatus Class I, DIV 2, GP A...D Class I, ZN 1, IIC T4 PROFIBUS-DP Ex i Terminating resistor Class
More informationEPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number
Fieldbus Gateway RS-232 to PROFINET EPGG001 Part Number Easy handling Gateway from RS-232/422/485 interfaces to PROFINET With two Industrial Ethernet ports Technical Data Electrical Data Supply Voltage
More informationCIS-331 Fall 2013 Exam 1 Name: Total of 120 Points Version 1
Version 1 1. (24 Points) Show the routing tables for routers A, B, C, and D. Make sure you account for traffic to the Internet. NOTE: Router E should only be used for Internet traffic. Router A Router
More informationShort Description. Version
S7-400 S7-400 CP 443-1 6GK7 443-1EX11-0XE0 V2.6 S7 CP for Industrial Ethernet ISO and TCP/IP with SEND/RECEIVE and FETCH/WRITE interface, long data, UDP, TCP, ISO, S7 communication, routing, module replacement
More informationData sheet CC 03, Commander Compact (603-1CC21)
Data sheet CC 03, Commander Compact (603-1CC21) Technical data Order. Type 603-1CC21 CC 03, Commander Compact General information Note - Features Display: 2 x 20 characters Interface: MP²I User memory:
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More informationMELSEC-F Series FX3U/FX3UC Main Units and Configuration
MELSEC-F Series FXU/FXUC Main Units and Configuration Speed ommunication FXU - Top of the Line Controllable I/O: - 8 points with CC-Link or AS-i remote I/O Main Unit I/O: //8//80/8 points Exchangeable
More informationSIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4
SIMATIC NET S7-CPs for PROFIBUS Manual Part B4 CP 443-5 Extended for PROFIBUS 6GK7 443-5DX04-0XE0 Version 1 or higher (Firmware Version V6.1 or higher) for SIMATIC S7-400 / S7-400H Status and fault LEDs
More informationSIMATIC S7-300 Product information for the S7-300 Automation System Manual, Module Data
SIMATIC S7-300 Product information for the S7-300 Automation System Manual, Data Product Information Introduction The present product information describes additions and corrections to the S7-300 Automation
More informationMotion Control System SIMOTION Controller based Platform. Update Catalog PM 10 September simotion. Update Catalog PM
Motion Control System SIMOTION Controller based Platform Update Catalog PM 10 September 2006 simotion s Update Catalog PM 10 2005 1 General Information Overview Design SIMOTION C is the modular controller
More informationKLIC-DI COMMERCIAL PRODUCT MANUAL INTERFACE KNX COMMERCIAL A/C UNIT ZN1CL-KLIC-DI. Edition 8 Version 1.6
PRODUCT MANUAL KLIC-DI COMMERCIAL INTERFACE KNX COMMERCIAL A/C UNIT ZN1CL-KLIC-DI Edition 8 Version 1.6 Index 1. Introduction... 3 2. Installation... 5 2.1. KLIC-DI Installation... 5 2.2. Elements Description...
More informationDigital Lighting Systems, Inc.
Digital Lighting Systems, Inc. Four Channel Dry Contacts Relays Switch Pack DMX512 compatible USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION The is a 4-channel DMX-512 compatible electro-mechanical
More informationSIMADYN D. Application Module FM 458. Contents. Definitions. Product description. Mounting. Configuring. ESD guidelines.
s SIMADYN D Application Module FM 458 User Manual Contents Definitions Product description Mounting Configuring 1 2 3 4 ESD guidelines 5 Order No.: 6DD1904-0AE0 Safety guidelines This Manual contains notices
More informationParameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:
CPU 315-2 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in the
More informationSIPLUS CPU 313C-2DP. Function
SIPLUS CPU 313C-2DP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in
More informationLimit Switches and Safety
Limit Switches and Safety Introduction Contents Pages 3SE International (IEC) Limit Switches 3SE5 General data Overview......................................... 13/4-13/9 3SE5 plastic enclosures 3SE5,
More informationdigiclip Data sheet DF31DP Special features B en
digiclip DF31DP Data sheet Special features Digital amplifier for industrial automation tasks and production process monitoring 600 Hz CF measurement technology with TEDS sensor detection for SG full bridges
More informationCommunications guide. Line Distance Protection System * F1* GE Digital Energy. Title page
Title page GE Digital Energy D90 Plus Line Distance Protection System Communications guide D90 Plus firmware revision:.9x GE publication code: 60-9070-F (GEK-3469) GE Digital Energy 650 Markland Street
More informationProduct Information. Release 3 4 SIMATIC S7-300
Product Information SIMATIC S7-300 Relay Output Module SM 322; DO 8 x REL AC230V/5A X 2 Release 3 4 New Relay Output Module Available The S7-300 Relay Output Module SM 322; DO 8 REL AC230V/5A has been
More informationCIS-331 Exam 2 Fall 2015 Total of 105 Points Version 1
Version 1 1. (20 Points) Given the class A network address 117.0.0.0 will be divided into multiple subnets. a. (5 Points) How many bits will be necessary to address 4,000 subnets? b. (5 Points) What is
More informationSIMATIC. PCS 7 process control system CPU 410 Process Automation/CPU 410 SMART. Preface 1. Introduction to the CPU 410. Configuration of the CPU 410 3
SIMATIC PCS 7 process control system CPU 410 Process Automation/CPU 410 SMART System Manual 05/2017 A5E31622160-AC Preface 1 Introduction to the CPU 410 2 Configuration of the CPU 410 3 PROFIBUS DP 4 PROFINET
More informationPRODUCT OVERVIEW CPM2A
PRODUCT OVERVIEW CPM2A Micro Controller CPU and Expansion Modules The CPM2A series micro controllers are among some of the most powerful small-scale control solutions in the micro PLC industry today. With
More informationS7-400 CPU ES XJ05-0AB0 V5.2 Work memory 144KB code and 144KB of data; ms/1000 instructions; 4KB DI/O; 32 connections 1*DP/MPI;
S7-400 CPU 412-1 6ES7 412-1XJ05-0AB0 V5.2 Work memory 144KB code and 144KB of data; 0.075 ms/1000 instructions; 4KB DI/O; 32 connections 1*DP/MPI; send and receive capability for direct data exchange;
More informationLoad Feeders. Communication-capable load feeders
Load Feeders /2 Introduction Communication-capable load feeders ET 200S /4 ET 200S motor starters /8 Power modules for ET 200S motor starters /9 SIGUARD safety systems for ET 200S motor starters /10 ET
More informationProduct type designation. General information. Supply voltage
Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1
More informationSIRIUS Safety Integrated. Modular safety system 3RK3
Functional Example CD-FE-I-048-V10-EN SIRIUS Safety Integrated Modular safety system 3RK3 Emergency Stop with monitored Start and Protective Door with automatic start according to category 4 in EN 954-1.
More informationAMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES
Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Two cards providing 8 channels of temperature and process monitoring for VM 600 systems 8 channels of software selectable
More informationPA ROUTERS. The following criteria can be applied when choosing the network transition:
PA ROUTERS To create a smooth network transition between PROFIBUS DP and PROFIBUS PA, the SIMATIC product range offers two versions: the DP/PA coupler and the PA link. The following criteria can be applied
More informationCPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS
CPU 319F-3 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Diagnostics buffer; the last 100 error and interrupt events are stored in a buffer
More informationOperator Control and Monitoring Devices
Siemens AG 007 Overview Compact, multi-functional operator panel for operator control and monitoring of machines and plants LED-backlit LCD: 4-line, 0 characters/line; character height 8mm system keys,
More informationST (6ES7132-6FD00-0BB1)
SIMATIC ET 200SP Digital output module DQ 4x24..230VAC/2A ST (6ES7132-6FD00-0BB1) Manual Edition 02/2014 Answers for industry. DQ 4x24..230VAC/2A ST Preface Guide to documentation 1 SIMATIC ET 200SP DQ
More informationUpgrading from MICRO/MIDIMASTER 2 to MICRO/MIDIMASTER 3
The new MICRO/ Vector range is designed to replace the existing MICRO/ in most applications without changing parameter settings, mounting arrangements, etc. In some cases the new (standard) range will
More informationPower Management System. Measuring Devices for Power Distribution
Power Management System Measuring Devices for Power Distribution Power Management System System overview /2 - Overview /2 - More information SENTRON Power Monitoring Devices General data /3 - Overview
More informationsirius Switching. Protecting. Starting. SIRIUS Product Overview
sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar
More informationRSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018
September 2018 Module Status LED Channel Status LEDs Digital Input Connector Ground 24 V DC FE Analog Input Module RSTI-EP Slice I/O Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664,
More informationData sheet VIPA CPU 214PG (214-2BE03)
Data sheet VIPA CPU 214PG (214-2BE03) Technical data Order. General information Note - 214-2BE03 VIPA CPU 214PG Features Work memory [KB]: 96 Interface [RJ45]: Ethernet PG/OP communication Interface [RS485]:
More informationDC-204R DC-204Ra SMART DYNAMIC STRAIN RECORDER. 200kHz 2GB UPS. Strain DC voltage Temperature. TML Pam E-442B. capacity. High speed sampling
TML Pam E-442B SMART DYNAMIC STRAIN RECORDER Standard With analog output DC-204R DC-204Ra Strain DC voltage Temperature High speed sampling 200kHz Large data recording 2GB capacity Automatic data storing
More informationSIMATIC FS600 laser scanner
Overview with pt covers Integration X2 X1 FS10_0018 Contact assignment Connection Description Position Connectable accessies Order No. X1 15-pin Sub-D connect f control interface $ Socket, complete, 15-pin
More informationGateway Ascii Command Protocol
Gateway Ascii Command Protocol Table Of Contents Introduction....2 Ascii Commands.....3 Messages Received From The Gateway....3 Button Down Message.....3 Button Up Message....3 Button Maintain Message....4
More informationSiemens.com/industrial-controls
SIRIUS Industrial Controls List 2018 Siemens.com/industrial-controls List of Contents Motor Control and Protection Soft Starters Motor Management - Simocode Monitoring Relays Commanding and Signaling Devices
More informationVersaMax Micro and Nano Technical Product Presentation
VersaMax Nano VersaMax Micro VersaMax Micro and Nano Technical Product Presentation Outline Introduction VersaMax Micro and Nano Product Strategy Future Products Product Description VersaMax Nano VersaMax
More informationGFK-2415A March Type of sensor connection
VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by
More informationCE DECLARATION of CONFORMITY
Manufacturers: Siemens Energy & Automation, Inc. Siemens AG 3000 Bill Garland Road Electronics Works Amberg Johnson City, TN 37601 Werner-von-Siemens-Str. 50 D-92224 Amberg Germany Manufacturer's Agent:
More informationData sheet VIPA CPU 214NET PG (214-2BT13)
Data sheet VIPA CPU 214NET PG (214-2BT13) Technical data Order. 214-2BT13 VIPA CPU 214NET PG General information Note - Features Work memory [KB]: 96 Integrated Ethernet CP 243 Interface [RJ45]: active
More informationSIMOREG DC-MASTER. Operating Instructions. 6RA70 Series. Microprocessor-Based Converters from 6kW to 2500kW for Variable-Speed DC Drives
s SIMOREG DC-MASTER Operating Instructions 6RA70 Series Microprocessor-Based Converters from 6kW to 2500kW for Variable-Speed DC Drives Edition 13 Order-No.: 6RX1700-0AD76 General 11.2007 These Operating
More information