1 Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) They react to sine-wave residual current (type AC) For protection: against dangerous contact with live parts (I Δn 30 ma) against dangerous contact with dead parts against fire or short circuit in reduced insulation capacity of electrical equipment (I Δn 300 ma) Possibility of additional mounting of auxiliary switches PS-OF-00 on the right side of the device Surge current resistance up to ka (8/20 μs) Possibility of interconnection with circuit breakers LPE (LPN) by means of interconnecting busbars 000 Residual current circuit breakers 2-pole Standard type for common use in building and housing installations up to 0 A, 230 V a.c. I Δn I n Type Product Number Weight Package [ma] [A] code of modules [kg] [pcs] 0 OFE--2-00AC OFE AC OFE AC OFE AC OFE AC OFE AC OFE AC Residual current circuit breakers -pole Standard type for common use in building and housing installations up to 80 A, 230/00 V a.c. I Δn I n Type Product Number Weight Package [ma] [A] code of modules [kg] [pcs] 2 OFE AC OFE AC OFE AC OFE AC OFE-2--00AC OFE-0--00AC OFE-3--00AC OFE AC OFE AC OFE AC OFE AC OFE-0--00AC OFE-3--00AC Accessories to OFE Auxiliary switch PS-OF-00 page C Busbar G2L-000-, GL-000- page D Connecting adapters AS-2-G, AS-2-S page D9 C8
2 Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) Specification Type OFE OFE Standards EN 008, IEC 7 EN 008, IEC 7 Approval marks Number of poles 2 Type AC AC Rated current I n, 2, 0 A 2, 0, 3, 80 A Rated residual current I Δn 0, 30, 00, 300 ma 30, 00, 300, 00 ma Rated operating voltage U e 230 V a.c. 230/00 V a.c. Min. operating voltag ) U min 00 V a.c. 00 V a.c. Max. operating voltage U max 20 V a.c. 20/ V a.c. Rated frequency f n 0/0 Hz 0/0 Hz Conditional short-circuit current I nc ka ka Maximum backup fuse 3 A gg 00 A gg Maximum backup circuit breaker LPE, LPN, LST I n of the circuit breaker I n of the residual current circuit breaker I n of the circuit breaker I n of the residual current circuit breaker Rated making and breaking capacity I m 00 A 800 A Surge resistance (8/20 μs) ka ka Release delay - - Mechanical endurance >0 000 operating cycles >0 000 operating cycles Electrical endurance >0 000 operating cycles >0 000 operating cycles Degree of protection IP20 IP20 Connection Conductor mm 2. 2 mm 2 Torque 3 Nm 3 Nm Opposite yes yes Operating conditions Ambient temperature - C - C Working position arbitrary arbitrary Seismic immunity 3 g / 8 0 Hz 3 g / 8 0 Hz ) For preserving the function of the test push-button Dimensions OFE OFE C9
3 Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) Diagram OFE OFE N 3 N 2 N 2 N Connection Residual -pólový current proudový circuit breaker chránič-pole v in -fázových -phase circuits obvodech with s N-pólem N-pole Residual -pólový current proudový circuit breaker chránič-pole v in 3-fázových 3-phase circuits obvodech without bez N-pólu N-pole L N L L2 L3 3 N 3 N 2 N OFE N OFE C0
4 AUXILIARY SWITCHES Residual current circuit breakers MINIA Auxiliary switch for residual current circuit breakers with overcurrent protection Accessories to OLFI and OLFE For signalling the position of contacts of residual current Installation: : on the right side of the residual current circuit breakers with overload protection circuit breaker with overload protection Type Product Arrangement Number Weight Package code of contacts ) of modules [kg] [pcs] PS-OLF ) Each digit indicates successively the number of make, break and break-make contacts Auxiliary switch for residual current circuit breakers Accessories to OFI and OFE Installation: on the right side of the residual current circuit breaker For signalling the position of contacts of residual current circuit breakers Accessories to Type Product Arrangement Number Weight Package code of contacts ) of modules [kg] [pcs] OFI, OFE up to 80 A PS-OF OFI 00, 2 A PS-OF ) Each digit indicates successively the number of make and break contacts Specification Type PS-OLF-000 PS-OF-00 PS-OF2-00 Standards EN 209 EN EN 209 EN 209 EN Approval marks Arrangement of contacts ) 00 Rated operating U e /I e AC V a.c. / A 230 V a.c. / A voltage / current AC- 230 V a.c. / A 230 V a.c. / 3, A - DC V d.c. / 0, A, 220 V d.c. / A 220 V d.c. / 0, A 2 V d.c. / A Min. voltage / current 2 V a.c. / 0 ma 2 V a.c. / 0 ma 2 V a.c. / 0 ma Short-circuit protection 2) MCB A, char. B or C MCB A, char. B or C 2) MCB A, char. B or C 2) fuse A gg fuse A gg fuse A gg Electrical endurance operating cycles operating cycles operating cycles Degree of protection IP20 IP20 IP20 Mounting on the right side of the device on the right side of the device on the right side of the device Connection Conductor - rigid (solid, stranded) 2. mm 2, 2x. mm mm mm 2 Conductor - flexible mm mm mm 2 Torque 0. Nm 0.8 Nm 0.8 Nm Opposite yes yes yes Operating conditions Ambient temperature -2 C 0 C -2 C C -2 C C Working position arbitrary arbitrary arbitrary ) Each digit indicates successively the number of make, break and break-make contacts 2) MCB - Miniature Circuit Breaker C
5 Residual current circuit breakers MINIA AUXILIARY SWITCHES Dimensions PS-OLF PS-OF PS-OF Diagram PS-OLF-000 PS-OF-00 PS-OF C
6 Residual current circuit breakers MINIA BASIC TERMS AND SYMBOLS Rated residual operating current I Δn is the value of residual current I Δn specified by the manufacturer, at which the residual current circuit breaker must switch out under specified conditions. Alternating residual current must by cut off by the residual current circuit breaker within (0. ) I Δn Rated current I n is the value of current specified by the manufacturer, which can be transferred by the residual current circuit breaker continuously. So the current I n can pass through the contacts for an unlimited time. Therefore it is, for instance, possible to use a residual current circuit breaker with I n =2 A in the circuit with max. current up to 2 A. For protection against overload of the residual current circuit breakers OFI, OFE, it is recommended to use the circuit breakers LSN, LST, LSE with rated current I n MCB I n RCCB Rated operating voltage U e is the voltage the residual current circuit breaker is to be connected to and which properties are related to. The connected voltage has no effect on the device function but on the function of the test circuit and isolation properties. Rated frequency f n is the frequency the residual current circuit breaker is designed for and at which it works correctly under stated conditions. Majority of residual current circuit breakers are designed for f n = 0 to 0 Hz. As the residual current circuit breaker function is based on the induction principle, the residual current behaviour and frequency show an effect upon tripping. When using a device designed for 0/0 Hz in a network with a different frequency, the user must count on a change of the tripping threshold i.e. a change of I Δn Conditional short-circuit current I nc short-circuit strength. The function and design principle does not allow to use the residual current circuit breaker for protection against short circuit. For circuit protection it is necessary to use a circuit breaker or a fuse. These elements cut the short-circuited circuit safely off. The residual current circuit breaker must only withstand the through-going short-circuit current. The amplitude of the maximum through current is defined as rated conditional short-circuit current I nc. The short-circuit strength is then expressed by the current I nc. For example, on the rating plate I nc = 0 ka is expressed by the following symbol: Ambient temperature T for the residual current circuit breakers is (- +0) C according to almost all international standards. Some residual current circuit breakers work in an extended range (-2 +0) C. This possibility is identified by the following symbol on the rating plate: Residual current circuit breaker type AC reacts to sine-wave residual current it is used in conventional AC networks Residual current circuit breaker type A reacts to sine-wave alternating and pulsating direct residual currents - it is used in conventional AC networks and the networks with phase power regulation etc. Residual current circuit breaker type G special residual current circuit breaker reducing the number of undesirable cut-offs. It is mainly installed before the devices causing short-time (up to 0 ms) stray currents. Identification: G Surge resistance: 3 ka (8/20 μs) Release delay: 0 ms G Residual current circuit breaker type S special residual current circuit breaker, which is mainly intended for selective switching of residual current circuit breakers and reduction of undesirable cut-offs. It is installed before the devices causing short-time (up to 0 ms) stray currents. Identification: S Surge resistance: ka (8/20 μs) Release delay: 0 ms S Selective (discriminating) switching means that if the residual current circuit breakers are connected in series, only the device in which circuit a failure occurs will cut off the current. More specifically, only the device in which the tripping residual current appears due to a failure in the protected circuit will turn off the current. The advantage consists in maintaining the power supply in the other circuits not affected by the failure. Such function of the protected circuit is achieved by connection of the selective residual current circuit breaker (see Fig. ) before the standard or G type residual current circuit breaker, with the following ratio of rated residual current: I Δn S 3 x I Δn -,G I ΔnS Rated residual operating current of the selective residual current circuit breaker I Δn -,G Rated residual operating current of standard or G type residual current circuit breaker The main reason of selective disconnecting of circuits is higher time delay of the selective residual current circuit breakers in tripping (compared to standard or G type ones). load I ΔnS = 0.3 A I Δn- = 0. A I = 0.03 A ΔnG load Fig. : Simplifi ed example of selective connection of residual current circuit breakers Residual current circuit breaker with overcurrent protection - the device is a combination of residual current circuit breaker and circuit breaker with 2-module width - it saves the space in the switchboard compared to conventional connection of two separate devices (3 modules). This eliminates the problem of primary protection and interconnection. The disadvantage of such a design compared to conventional one is that it is not possible to identify whether the tripping was actuated by the residual current circuit breaker or by the circuit breaker. C7
7 INTERCONNECTING BUSBARS Interconnecting busbars For interconnection of to -pole circuit breakers, tumbler switches, residual current circuit breakers, lightning current arresters and surge voltage arresters For interconnection of a series of single-phase or threephase circuit breakers and tumbler switches, on which an auxiliary switch is mounted switch fork pin Busbars GL-.., G2L-.., G3L-.., GL-.. with forks into the head part of the terminal, Busbars SL-.., S2L-.., S3L-.., SL-.. with pins into the clamp part of the terminal Busbar Number Output Number Cross-section Type Product End cap Weight Package shape of poles spacing [mm] of outlets [mm 2 ] 2 0 GL ) GL ) GL GL GL GL ) GL EKC GL ) 37 2 GL x 28 G2L EKC x 2 0 G3L ) G3L ) G3L x G3L G3L x G3L ) x 9 0 G3L-000-0C 373 EKC G3L-000-C 3739 EKC x G3L EKC x GL EKC x G3L+N EKC SL ) SL EKC SL EKC SL EKC SL x 28 S2L EKC x 9 S3L EKC S3L EKC x 2 2 S3L EKC x 9 2 SL EKC ) The busbar is manufactured as enclosed one 2) For single-pole devices with auxiliary switch Accessories End caps For covering the ends of connecting busbars Type Product Description Weight Package EKC for -pole rails cross-section 0, 2, mm EKC for 2-pole rails and for 3-pole rails cross-section mm EKC for 3-pole rails cross-section 0 mm EKC for 3-pole rails and for -pole rails cross-section 2 mm EKC for -pole rails cross-section mm Power supply unit It enables power supply of interconnecting busbars by conductors of cross section up to 3 mm 2 The blocks can be assembled in series to create a multipole connection unit. Degree of protection IP20 Type Product Weight Package ES-3-GS D
8 INTERCONNECTING BUSBARS Specification Type G.., S.. Rated operating voltage U e V a.c. Max. operating voltage U max 00 V a.c. Loading current 3 80 A Cross-section 0 2 mm 2 Short-circuit strength with primary fuse 20 A gg 0 ka Overvoltage category III Busbar material E-Cu-F2 Insulation material PC/ABS-Blend Max. loading current per phase Rail cross-section 0 mm 2 2 mm 2 mm 2 20 mm 2 2 mm 2 2 mm 2 Power supply from the rail edge 3 A A 80 A 90 A 00 A 00 A Power supply from the rail centre ) 00 A 0 A 30 A 0 A 70 A 80 A ) Max. loading current in one direction must not be higher than max. loading current at power supply from the rail edge Diagram GL-.., SL-.. G2L-.., S2L-.. G3L-.., S3L-.. GL-.., SL-.. G3L+N-.. L L L2 (N) L L2 L3 L L2 L3 N L N L2 N L3 N D
9 INTERCONNECTING BUSBARS Dimensions GL-30-0, GL-0-0, GL-20-0 GL x 7 2. G-L--000/2 972 x G2L x (GL-30-0) 0 (GL-0-0) 20 (GL-20-0) 99.8 x GL-30-, GL-0-, GL-20- GL (GL-30-) 0 (GL-0-) 20 (GL-20-) 7 G3L-0-0, G3L-0-0, G3L-20-0 G3L-000-0C x 9 G3L-0-, G3L-0-, G3L-20- G-3L-000/C x (G3L-0-0) 0 (G3L-0-0) 20 (G3L-20-0) 0 (G3L-0-) 0 (G3L-0-) 20 (G3L-20-) G3L x 2.8. GL-000-, G3L+N x D
10 INTERCONNECTING BUSBARS Dimensions SL-20- SL x x SL-000- x SL x SL S2L-000- x x S3L-000- S3L x x S3L SL x x ES-3-GS D7
11 INTERCONNECTING BUSBARS Examples of use of interconnecting busbars INTERCONNECTING BUSBARS WITH FORKS -pole interconnecting busbars For interconnection of -pole devices in the head part of the terminal Use: LPE, LPN, SJB, SVL, SVM, APN -pole interconnecting busbars with spacing mm For interconnection of -pole devices with auxiliary switch in the head part of the terminal Use: LPE, LPN, APN 2-pole interconnecting busbars For interconnection of 2-pole devices in the head part of the terminal Use: LSN, LSE, SVL, SJL, ASN 3-pole interconnecting busbars For interconnection of 3-pole devices in the head part of the terminal Use: LPE, LPN, SJB, SVL, SVM, APN 3-pole interconnecting busbars with a gap on the auxiliary switch For interconnection of 3-pole devices with auxiliary switch in the head part of the terminal Use: LPE, LPN, APN -pole interconnecting busbars For interconnection of -pole devices in the head part of the terminal Use: LPE, LPN, OFI, OFE, APN INTERCONNECTING BUSBARS WITH PINS -pole interconnecting busbars For interconnection of -pole devices in clamp part of the terminal Use: LPE, LPN, SJB, SVL, SVM, APN -pole interconnecting busbars with spacing mm For interconnection of -pole circuit breakers LST in clamp part of the terminal or for interconnection of -pole devices with auxiliary switch in clamp part of the terminal Use: LPE, LPN, LST, APN, AST 2-pole interconnecting busbars For interconnection of 2-pole devices in clamp part of the terminal Use: LPE, LPN, OLFE, OLFI, OFE, OFI, APN 3-pole interconnecting busbars For interconnection of 3-pole devices in clamp part of the terminal Use: LPE, LPN, APN 3-pole interconnecting busbars with spacing mm For interconnection of 3-pole circuit breakers LST in clamp part of the terminal or for interconnection of -pole devices with auxiliary switch in clamp part of the terminal Use: LPE, LPN, LST, APN, AST -pole interconnecting busbars with spacing mm For interconnection of -pole circuit breakers LST in clamp part of the terminal Use: LST, AST D8
12 CONNECTING ADAPTERS Connecting adapter up to 2 mm 2 with fork For connection of another conductor to the head part of the terminal of a circuit breaker, residual current circuit breaker, tumbler power switch etc. For example, the best solution is to connect a conductor for power supply of an electric meter in the clamp part of the circuit breaker terminal, and another conductor through the connecting adapter AS-2-G in the head part of the circuit breaker terminal Conductor cross-section: 2 mm 2 Type Product Accessories Weight Package AS-2-G LPE, LPN, OLFI, OLFE, OFI, OFE, SJB, SVM, APN Connecting adapter up to 2 mm 2 with pin Accessories to: OFI20, OFE20, SVL, SJL, RP Conductor cross-section: 2 mm 2 For connection of conductors to the clamp part of the terminal Type Product Accessories Weight Package AS-2-S OFI , OFE , RLP Connecting adapter up to 0 mm 2 For connection of Al or Cu conductors Cross-section of Cu conductors: 2. 0 mm 2 Cross-section of Al conductors: 0 mm 2 Type Product Accessories Weight Package AS-0-S-AL 3739 LPE, LPN, LST, SJBplus, APN, AST 0.08 Connecting adapters up to 9 mm 2 For connection of Cu/Al conductors of cross section 3 9 mm 2 With direct or outbowed terminal Type Product Accessories Weight Package CS-FH000-3NP9 370 straight guidon the package contains the set of 3 pieces LST, SJBplus, SJB-NPE, AST 0.7 CS-FH000-NP9 378 straight guidon LST, SJBplus, SJB-NPE, AST 0.0 CS-FH000-3NV9 372 outbowed guidon the package contains the set of 3 pieces LST, SJBplus, SJB-NPE, AST 0.8 Connecting adapter 3x0 mm 2 For connection of 3 conductors / device pole of cross section 0 mm 2 Type Product Accessories Weight Package N3x0-FH000 LST, SJB, SVM, AST 0.03 D9
13 CONNECTING ADAPTERS Dimensions AS-2-G 7 AS-2-S AS-0-S-AL N3x0-FH CS-FH NP9 2 CS-FH000-3NV Examples of use of connecting adapters and blocks AS-2-G For connection of another conductor of cross section up to 2 mm 2 to the head part of the terminal Use: LPE, LPN, OLFI, OLFE, OFI, OFE, SJB, SVM, APN AS-2-S For connection of conductors of cross section up to 2 mm 2 to the clamp part of the terminal Use: OFI , OFE , RLP AS-0-S-AL For connection of Cu/Al conductors of cross section up to 0 mm 2 to the clamp part of the terminal Use: LSN, LST, LSE, LFI, LFE, SJBplus, ASN, AST CS-FH000-3NP9, CS-FH000-NP9, CS-FH000-3NV9 For connection of Cu/Al conductors of cross section up to 9 mm 2 to the clamp part of the terminal Use: LST, SJBplus, SJB-NPE, AST N3x0-FH000 For connection of three conductors of cross section 0 mm 2 to the clamp part of one terminal Use: LST, SJB, SVM, AST D70
MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)
MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationDIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations
More informationAllen-Bradley 1492-RCDA4A40
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps
More informationOvervoltage Protection Devices
Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12
More informationOTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application
Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical
More informationMiniature Circuit-Breaker IEC Series 8562
> 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips
More informationC C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description
CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size 000
More informationMiniature Circuit Breakers for Railway Applications
Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent
More information5SL Miniature Circuit Breakers
5SL Miniature Circuit Breakers BETA Low-Voltage Circuit Protection The new 5SL miniature circuit breaker is intended for use up to ka. The devices have the system features characteristic of all Siemens
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationLightning and Surge Arresters
Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement
More informationCombined RCD/MCB Devices FRBmM, 1+N-pole
Combined RCD/MCB Devices FRBmM, 1+N-pole SG13711 High-quality residual current device / miniature circuit breaker combination, line voltage-independent Contact position indicator red - green Fault current
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationRCDs RCBOs MCBs Isolating Switches Switchboards
RCDs RCBOs MCBs Isolating Switches Switchboards 1300 722 275 F: 1300 738 717 RCD 4 Pole 6KA RCDs monitors at all times the current flow and will cut the electrical supply in case of an imbalance. Suitable
More informationResidual Current Devices drcm Digital
Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents.
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60
DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery
More informationResidual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008
Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Wide range of compact types of RCDs serving as fault-current and additional protection according to UL1053 & IEC/EN 61008 standards,
More informationSurge Protection Devices Ex9UE2
Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,
More informationMULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing
MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More informationQUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)
DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery
More informationAdd-on Residual Current Protection PBSM MW
SG_Bestell_MV_E.qxd 25.04.2005 09:39 Seite 36 Add-on Residual Current Protection PBSM MW By combining this device with a top-quality miniature circuit breaker of type PLS. (except PLSN) a top-quality RCBO
More informationExtract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards
Extract from the online catalog SFP 1-5/120AC Order No.: 2920667 Device surge protection filter to limit powerful surge voltages, mounting on NS 35. Commercial data EAN 4046356158558 Pack 1 pcs. Customs
More informationST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077
MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary
More informationMonitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064
Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window
More informationJtec 10kA Miniature Circuit Breaker
Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide
More informationMotor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital Line-voltage independent, all-current sensitive RCCB for fault or additional protection with additional digital features System Monitoring: Preventive
More informationThe new Arc Fault Detection Device S-ARC1 Maximum safety easy installation
ARC FAULT DETECTION DEVICE (AFDD) The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation The S-ARC1 is the new Arc Fault Detection Device (AFDD) with an integrated Miniature Circuit
More informationOvervoltage Protection Devices
Siemens AG 2013 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital All-current sensitive RCCB for fault or additional protection Digital Features System Monitoring: Preventive information / warning before the RCD
More informationTechnical features OVR Surge Protective Devices Type 1 & Type 1+2
Type 1 & Type 1+2 TECHNICAL FEATURES Technology Type 1 OVR T1 2 TS Triggered spark-gap Electrical features Standard IEC 61643-1 / EN 61643-11 Type / test class 1 / I Poles 1P - 1P -, 2P 2L 3P 3L 4P 4L
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationMotor protection circuit breakers
R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,
More informationARC FAULT DETECTION DEVICES AFDD
Function principle of arc fault detection devices AFDD... D2 Summary of models and description of ARC fault detection devices AFDD... D5 ARC fault detection units ARC... D8 ARC FAULT DETECTION DEVICES
More informationAutoprotected Surge Arresters New OVR Plus range
Autoprotected Surge Arresters New OVR Plus range A complete solution with the OVR PLUS range Thanks to its continuous innovation on surge protection, ABB improves constantly its offer by launching on the
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationThermal-Magnetic Circuit Breaker 4220-T...
Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With
More informationMinia. Application manual Overvoltage protections
Minia Application manual Overvoltage protections www.oez.com Overvoltage protections Minia CONTENTS THEORETICAL PART 1. PRINCIPLE OF PROTECTION AGAINST LIGHTNING AND OVERVOLTAGE... 3 1.1. Switching overvoltage...
More informationCC COMPACT DIP SWITCH
CC COMPACT DIP SWITCH COMFORTLINE DIP SWITCH C-R5 186841, 186842, 186843 Typical Applications Built-in in compact luminaires for Shop lighting Downlights Panels ComfortLine DIP switch C-R5 SELECTABLE OUTPUT
More informationVAL-CP-1S-175. Extract from the online catalog. Order No.:
Extract from the online catalog VAL-CP-1S-175 Order No.: 2859479 Pluggable type 2 arrester (surge arrester) for 1-phase current supply networks with separate N and PE (3-conductor system: L1, N, PE), with
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationQUINT-PS/ 1AC/24DC/ 5
Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)
More informationInstallation / Control Technique
Installation / Control Technique Interface Relay, Interface Relay System Input-Output Interface Relay IK 3070, I_ 3070 0633 IK 3070 Circuit Diagrams IS 3070 According to IEC/EN 61 810-1 Relay, triac or
More informationDSE201, DSE201 M Compact design with enhanced protection
DSE20, DSE20 M Compact design with enhanced protection Ultimate safety DSE20 and DSE20 M: the highest level of reliability The P+N electronic residual current circuit-breakers with overcurrent protection
More informationmcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches
NEW P. 4 RX3 MCBs 63 A 4500 & 6000 prong type busbar MCBs, RCDs, add-on modules & accessories P. 9 DX3 RCBOs 63 A 6000 / 10 ka AC, A & Hpi type prong & fork type busbar P. 16 DX3 MCBs 63 A 50 ka mcbs,
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors
More informationRB60 RANGE. Miniature circuit breakers
RB60 RANGE Miniature circuit breakers POWER 2015 RB60 range Miniature circuit breakers Miniature circuit breakers for circuit protection The miniature circuit breakers RB60 are designed for the protection
More informationPT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 2-PE/S- 24AC-ST Order No.: 2839318 The illustration shows version PT 2-PE/S-230 AC-ST Protective plug PT with surge voltage equipment protection for power supply units,
More informationOvervoltage Protection Devices
Siemens AG 2014 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 combination surge arresters, type 1 / type
More informationCOMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,
COMPACT LED DRIVERS EasyLine SIMPLE FIX 186591, 186592, 186593, 186594, 186595, 186669 Typical Applications Built-in in or independent version for Shop lighting Downlights EasyLine with fixed output current
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationResidual Current Protective Devices / Arc Fault Detection Devices
Residual Current Protective Devices / Arc Fault Detection Devices SENTRON Configuration Manual Edition 10/015 siemens.com/lowvoltage Introduction 5SV / 5SM3 RCCBs 13 SIQUENCE 5SM3/5SU1 universal current
More informationQUINT-PS AC/24DC/10
Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs
More informationVEO. V2UF230V10 Art.Nr.: TECHNICAL DATA
Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after
More informationContact protection relay
Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only hydraulically delayed switching characteristics
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationIntroduction Circuit Protection
Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short
More informationCONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection
CONTA-ELECTRONICS CONTA-PROTECT overvoltage protection When choosing the correct device for overvoltage protection, it is important to consider the regulations VDE 110-1, IEC 61643-1, EN 61643-11 and VDE
More informationMiniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.
Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC Similar to illustration Partno. FAZ-B16/3 CatalogNo. 278847 EatonCatalogNo. FAZ-B16/3 EL-Nummer 1695123 Deliveryprogram Basic function Miniature circuit-breakers
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More informationLINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,
LINEAR LED DRIVERS EasyLine SIMPLE FIX 186712, 186713, 186714, 186715, 186716, 186760 Typical Applications Built-in in linear luminaires for Office lighting Weatherproof Luminaires EasyLine Simple Fix
More informationSurge Protection Devices and Surge Protection Kit
Surge and Surge Kit SPD s protect electrical and electronic equipment against transients, originating from lightning, switching of transformers, lighting and motors 3. Main protection - class 3 To cut-down
More informationQUINT-PS/ 1AC/24DC/20/CO
Extract from the online catalog QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective
More informationFor Sales and Support call KMParts.com (866)
Overcurrentswitch,5A,1p,B-Char,AC Partno. FAZ-B5/1 Articleno. 278528 CatalogNo. FAZ-B5/1 Similar to illustration Deliveryprogram Basic function Miniature circuit breakers Number of poles 1 pole Tripping
More informationLightning and Surge Arresters
/ Lightning and Surge Arresters Product overview /3 Introduction /6 Lightning arresters, requirement category I (B) /8 Combination arresters, requirement category I (B) and II (C) /0 Single-pole surge
More informationMINI-PS AC/10-15DC/8
Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a
More informationW DATA SHEET: RCBO COMBINED MCB AND RCCB SERIES BOLF 1+N
W DATA SHEET: RCBO COMBINED MCB AND RCCB SERIES BOLF 1+N Seybelgasse 13, A - 1230 Wien, TELEFON +43 1/866 85-0 E-MAIL info@schrack.at, INTERNET www.schrack.at PAGE 1/26 W RCBO COMBINED MCB AND RCCB SERIES
More information3 Pole Contactors with AC operating coils
1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to
More informationElectronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F Approvals a culus f CCC CT-BS Circuit diagram Marker label Marks g c CE C-Tick Order data
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationRE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC
Characteristics adjustable off-delay timing relay - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay
More informationZB5FG09 flush mounted selector switch head key pos stay put
Characteristics flush mounted selector switch head key 455 3 pos stay put Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device short name XCKJ Sensor
More informationCOMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)
COMPACT LED DRIVERS PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) 186762, 186763 Typical Applications Built-in in compact luminaires Shop lighting Downlights PrimeLine DALI dimmable & Selectable
More informationOvervoltage Protection Devices
Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge arresters, type
More informationic60n RCBO 30 ma IEC , IEC , AS/NZS
ic60n RCBO 30 ma DB405571 Country approval pictograms IEC 61009-1, IEC 61009-2-2, AS/NZS 61009.1 PB110075-70 b The single-phase ic60n RCBO s self-contained residual current device provides protection of
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationTeSys contactors From 115 to 2750 A
Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,
More informationElectronic timer CT-ARS.11
2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact
More informationControl elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.
On-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status
More informationCOMPACT LED CONVERTERS 48 V
COMPACT LED CONVERTERS 48 V EasyLine 48 V 186691, 186692 Typical Applications Shop lighting for 48 V systems Furniture lighting EasyLine 48 V VERY COMPACT SHAPE VERY LOW RIPPLE CURRENT LONG SERVICE LIFETIME:
More informationSPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters
The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects of transient over voltages caused by
More information1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers
.2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................
More informationVEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA
4 time ranges 4 transition times Supply voltage 12-240V AC/DC 2 normally open contacts Width 22,5 mm Control elements Fine adjustment star contactor Setting of time range star contactor Transit time Status
More informationVEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA
Off-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5 mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status
More informationTT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:
Extract from the online catalog TT-ST-M-2-PE-24DC Order No.: 2858904 TERMITRAB, spring-cage modular terminal block with integrated surge protection and disconnect knives, for assembly on NS 35/7.5, voltage
More informationPHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.
Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.
More informationDX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationTechnical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n
Safety module CS AT 0 Module for emergency stops, end position monitoring for movable guards with delayed contacts at the opening of the input channels, semiconductor outputs (e.g. light barriers and magnetic
More informationCOMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,
COMPACT LED DRIVERS EasyLine SIMPLE FIX 186719, 186720, 186721, 186722, 186723, 186724, 186725, 186726, 186727, 186728 Typical Applications Built-in in compact luminaires Shop lighting Downlights EasyLine
More information