Residual current circuit breakers
|
|
- Georgia Mason
- 6 years ago
- Views:
Transcription
1 circuit breakers (RCCB) The residual current circuit breakers are most up-to-date devices mainly used for protection against indirect contact, but in some cases also against direct contact. The residual current breaker automatically starts to operate if the defect current (eg. insulation defect, short circuit etc.) in the protected network exceeds a critical value. Installation is suggested and in some cases even compulsory, in outdoor connections, in building site boxes, concrete mixers, bathrooms, etc. Over 6000 A independent short circuit current one must be use a shunt fuse! Technical data Rated operating voltage: 230 / 400 V Rated insulating voltage: 500 V Applicable shunt fuse: F type: max. 63 A gg TFV/G type: 80 A gg (16, 25, 40 A) TFV/G type: 100 A gg (63 A) TFVH type: 125 A gg ( A) Accessories Withstand against short circuit (with shunt fuse): 25 ka Electrical/ Mechanical lifetime: 4 000/ switch Protection against outer effects: impact resistant and UV-proof cover Protection degree: IP 40 Type of termination: With female clips Terminal capacity: 2, mm 2 Ambient temperature: -25 C C Accessories F TFV TFVH TFG TFIG ED Distribution boxes TFSS-... ormal and spade type connecting rails TFSS-1CS Screw terminal - 35/7.5 SI Mounting rails according to E Range of type E Tracon Rated short circuit Rated residual breaking Type of code breaking ability current operation Sensitivity F 25, 40, 63 6 ka 30, 100, 300, 500 AC TFV 16, 25, 40, 63 6 ka 30, 100, 300 AC Alternate current TFVH 80, 100, ka 30, 100, 300 AC TFG 16, 25, 40, 63 6 ka 30, 100, 300 A; AC TFGA 16 (plug-in type) 6 ka 30 A; AC Alternate and pulsing direct current TFIG 16, 25, 40, 63, 80, ka 30, 100, 300 A; AC F residual current circuit breakers RCCB for the reliable, good quality C60 circuit breaker family. umber of poles F2P F2P F2P F2P F2P F2P F2P F2P F2P F2P F2P F2P F4P F4P F4P F4P F4P F4P F4P F4P F4P F4P F4P F4P Tracon Budapest td. Pallag Street 23, Dunakeszi, H-2120, Hungary E/21
2 TFG residual current circuit breakers These RCCB-s are applicable for TDZ, TDS and TDA circuit breakers, containing trip unit for contaminated AC and pulsing DC currents, too. ET-SEMKO CERTIFICATE O TFG IECEE- CB CERTIFICATE O. C-2734 umber of poles TFG TFG TFG TFG TFG TFG TFG TFG TFG TFG TFG TFG TFG TFG TFG TFG TFG TFG TFG TFG TFG TFG TFG TFG TFGA adaptor with residual current circuit breaker The TFGA type adaptor with residual current circuit breaker is a very modern protective device against direct touch of electric network with protective conductor, moreover in such of cases protects against indirect touch, too. The RCCB switches off automatically when the leakage current is too high on the protected network. Being portable, it can be used for any network not provided with residual current protection. The device can be switched on by the RESET button. Before first use the operation of the device must tested by the TEST button; after pushing the button the device has to switch off the plug from the network. While using the device continuously it must be tested monthly by pushing the TEST button. After installing the adaptor the protected device or net can be plugged into the socket-outlet. Technical data Power supply: : Max. load: : Tripping time: 230 V AC 50 Hz 16 A 3600 W 30 ma < 30 ms Protective contact Type Protection degree TFGA-1 side normal IP 40 TFGA-4 side with cover IP 44 TFGA-1F male normal IP 40 TFGA-4F male with cover IP 44 ET-SEMKO CERTIFICATE O E HD 639 S1 TÜV MEEI TEST DOCUMETATIO M E/22 Tracon Budapest td. Pallag Street 23, Dunakeszi, H-2120, Hungary
3 TFV residual current circuit breakers These RCCB-s are applicable for TDZ, TDS and TDA circuit breakers. umber of poles TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TFV TÜV MEEI TEST DOCUMETATIO IECEE-CB CERTIFICATE O. CCA CERTIFICATE O. D0461V092 E HU-328, C 872 CCA/HU0212/A1 TFVH residual current circuit breakers for high current These residual current circuit breakers are suitable for KMH type high current circuit breakers. umber of poles TFVH TFVH TFVH TFVH TFVH TFVH TFVH TFVH TFVH TÜV MEEI TEST DOCUMETATIO M Tracon Budapest td. Pallag Street 23, Dunakeszi, H-2120, Hungary E/23
4 Motor-driven automatic re-connection device General description of operation: This device automatically re-connects the previously disconnected consumer (due to overcurrent generated by failure or atmospheric phenomena), once the current into the circuit has fallen back into the normal range. Such devices are an advantage in places where circuit break-off is expected to take long until the arrival of the service personnel (telecommunication stations, traffic control by signal lamps, remote control switching devices). The cause of the overcurrent is usually transitory, long tome interruption is unnecessary and causes important disturbance. Operation properties Re-connection devices are easy to be installed and adjusted. For automatic operation just pull the convex cover in the direction of the O arrow. If the re-connection device fails to re-connect the controlled circuit breaker after the pre-set number of attempts (1-8), the break-off status will persist. Once the defection causing break-off was eliminated, the contactor can be switched on manually. For maintenance work on the circuit, before switching off the circuit breaker, the convex cover of the re-connection device shall be pushed in the direction of the OFF arrow; otherwise the reconnection device will automatically switch on the circuit breaker. To prevent unwanted reconnection, the re-connection device can be locked. Technical data Circuit breaker Motor-driven automatic re-connection device 25 A, 40 A, 63 A, 80 A - Rated fault current 30 ma, 100 ma, 300 ma - Rated short-circuit break-off capacity 10 ka - Rated operating voltage 240 / 415 V ~ V ~ o-load current - 1,5 VA Adjustable number of re-connections - 1, 2, 4, 6, 8 Break-off time / Switch-off time 0,1 s 1 s Switch-on time - 2 s Adjustable re-connection time delay s Status ED-s - green: O, red: OFF, flashing red: waiting for re-connection Manual O / OFF switching with handle with the convex cover Electrical life switches Mechanical life switches oad-bearing of the auxiliary contact VAC, 5 A Remote control input - C / O / CO Ambient temperature C C Degree of protection box: IP40, terminals: IP20 box: IP40, terminals: IP20 Accepted wire cross-section Max. 25 mm² Max. 1,5 mm² 2 poles 4 poles IΔn= 30 ma IΔn= 100 ma IΔn= 300 ma I th IΔn= 30 ma IΔn= 100 ma IΔn= 300 ma I th TFIG TFIG TFIG TFIG TFIG TFIG TFIG TFIG TFIG TFIG TFIG TFIG TFIG * TFIG * TFIG TFIG TFIG * TFIG TFIG TFIG TFIG TFIG TFIG TFIG * 63 TFIG TFIG TFIG TFIG TFIG TFIG *Available from stock; other types can be ordered with 4 weeks shipping time IECEE-CB CERTIFICATE O. SEMKO CERTIFICATE O. E E SE SH V1 E/24 Tracon Budapest td. Pallag Street 23, Dunakeszi, H-2120, Hungary
5 Control units of device The control units of automatic reconnect device can be found on the right side of dome cover as follows: The potential-independent auxiliary contacts and the remote operation contacts can be found in one row next to each other. The possible connections are: C open auxiliary contact, O close auxiliary contact, connection for O remote pushbutton connection for O remote pushbutton With Reset Counter button user can reset the digital release counter and the device is getting back to normal operation state. The Power ED with changeable color can inform the user about operation state of device as follows: - Green: normal operation; - Red: locked; - Blinking red: reconnection operation is under process. With the help of the button found on the left side of the next row, user can select the number of reconnection attempts (1; 2; 4; 6 or 8). With the button on the right side of this row one can select the delay between reconnection attempts (10; 30; 60; 120 or 180 sec). Under these buttons the digital displayed release counter was placed. Under the display were placed the connection terminals ( and ) for power supply of automatic unit Slider switch IECEE-CB CERTIFICATE O. SEMKO CERTIFICATE O. E E SE SH V1 Installation instructions The main line of the device to be protected must connect to the device in the ordinary way. The 230 V, 50 Hz power supply for automatic unit must connect to and terminals with correct polarity. This supply can get both from the supply side of residual current breaker or from other independent power source. Usage and safety cuit ker Supply Remote alarm O OCKED COSE OPE COMMO Always use the rated power supply! Before installation the power supply must be switched off! Always use proper voltage measuring unit to verify the potential free status of network! The installation must be completed always by an expert observing the relevant installation rules! I OUT To oad 230 V AC Tracon Budapest td. Pallag Street 23, Dunakeszi, H-2120, Hungary E/25
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital All-current sensitive RCCB for fault or additional protection Digital Features System Monitoring: Preventive information / warning before the RCD
More information5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...
.1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital Line-voltage independent, all-current sensitive RCCB for fault or additional protection with additional digital features System Monitoring: Preventive
More informationOTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application
Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationResidual Current Devices drcm Digital
Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents.
More informationCombined RCD/MCB Devices FRBmM, 1+N-pole
Combined RCD/MCB Devices FRBmM, 1+N-pole SG13711 High-quality residual current device / miniature circuit breaker combination, line voltage-independent Contact position indicator red - green Fault current
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationMiniature Circuit-Breaker IEC Series 8562
> 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More informationRedline. Extensions. Display contacts. Function S. Display contact CA. Function. Add-on Devices T3.2
Redline Extensions All MCB s (except G20), RCCB s (except Delta B) & RCBO s are designed to accept the same family of extensions. Main device ON Normal working status Addon Devices The extensions intended
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationCP30F Series Circuit Protector for Improving Safety and Wiring Workability
CP30F Series Circuit Protector for Improving Safety and Wiring Workability EMURA, Takeshi * A B S T R A C T A circuit protector is a circuit-breaker that possesses both overcurrent protection and switch
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationResidual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008
Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Wide range of compact types of RCDs serving as fault-current and additional protection according to UL1053 & IEC/EN 61008 standards,
More informationJtec 10kA Miniature Circuit Breaker
Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide
More informationRCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions
RCD Fused Connection Unit Model: RCD10WPV RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV Installation & Operating Instructions General The Timeguard range of RCDs provides protection
More informationMINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)
MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationSACE Emax 2 Specification guide
SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or
More informationWiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3
Wiring diagrams Content Information for reading and graphic symbols... 5/2 Wiring diagrams of the circuit-breakers... 5/3 Electrical accessories... 5/4 5/1 Information for reading and graphic symbols State
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationAdd-on Residual Current Protection PBSM MW
SG_Bestell_MV_E.qxd 25.04.2005 09:39 Seite 36 Add-on Residual Current Protection PBSM MW By combining this device with a top-quality miniature circuit breaker of type PLS. (except PLSN) a top-quality RCBO
More informationCurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.
CurrentWatch Current Sensors Ground Fault Sensors with Solid-State or Mechanical Relay s 1 Contents Overview.................... 1 Model Selection, Switches...... 2 Model Selection, Accessories... 3 Wiring
More information9926 Series Branch Rated Circuit Breakers AC Version
Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering
More informationAllen-Bradley 1492-RCDA4A40
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps
More informationSwitching module for AC V and up to three load stages, with manual switching
8 149 PTM13-M3 DESIGO I/O modules Switching module for AC 24 250 V and up to three load stages, with manual switching PTM13-M3 Signal converter for connection to P-bus, with three interlocked on/off control
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationCircuit Protectors CP31E, 32E, 33E, 34E CP31V, 32V, 33V, 34V
CP3E, 32E, 33E, 34E CP3V, 32V, 33V, 34V CP-E and CP-V circuit protectors 250V AC 0.05A to 30A 65V DC 0.05A to 30A Description CP-E, CP-V circuit protectors have been specially developed for computers,
More informationPGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 0-C-041918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationAS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input
Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationSafety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E
EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0
More informationMotor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)
More informationMiniature Circuit Breakers for Railway Applications
Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent
More informationRESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)
Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) They react to sine-wave residual current (type AC) For protection: against dangerous contact with live parts (I Δn 30
More informationRUC industrial relays of small dimensions
Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Max. breaking capacity
More informationSurge Protection Devices Ex9UE2
Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,
More informationOvervoltage Protection
Overvoltage Protection Weidmuller has a complete line of overvoltage protection devices to effectively stop the harmful effects of electrical overvoltage and electrical noise. There is strong potential
More informationC C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description
CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated
More informationSelection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size 000
More informationTable of Contents Protective Devices / Components
Eaton www.eaton.eu Protective Devices Table of Contents Protective Devices / Components 1. Protective Devices Residual Current Devices (RCDs)................................................. Page xx Residual
More informationBNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS
BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS Safety Controller Suitable for use with Coded-Magnet Sensor Part Numbers below BNS250... BNS33... BNS303...
More informationMiniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data :
Miniature Circuit Breakers reliable solutions for protection of installations against over-current phenomenon Advantages for you : Bi-connect terminals for simultaneous termination of bus bar & wires Unique
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationITEM ESM-BA301
ITEM 085613 ESM-BA301 Description Technical data Accessories Downloads Features ESM-BA.. Usage up to category 4 according to EN ISO 13849-1 LED status indicators 1-channel or 2-channel control 3 redundant
More informationInstallation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE
IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationF550e E-learning course Residual current devices basics RCDs Standards. ABB Group April 2, 2009 Slide 1
F550e E-learning course Residual current devices basics RCDs Standards April 2, 2009 Slide 1 Objectives After completing this module, you will be able to have a clear overview of the residual current device
More informationTeSys protection components
Description, characteristics -pole electronic thermal overload, TeSys LR9D0, 0, 08, and LR9D0S DB8880.eps 7 / & 8 Description LR9D0, 0, 08 and self-powered electronic thermal overload are designed for
More information1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection
Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output
More informationRUC industrial relays of small dimensions
with adaptor (V) with adaptor (H) Power relays of general application AC and DC coils Mounting: in sockets; 35 mm rail mount acc. to PN-EN 60715; on panel; PCB Versions: faston 187 (4,8 x 0,5 mm); faston
More informationDatasheet SRB301ST 24V (V.2)
26.10.2016 05:03:31h Datasheet SRB301ST 24V (V.2) Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301ST Suitable
More informationSafe monitoring relays
monitor for safe standstill monitoring Approvals Block diagram Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous LED indicator
More informationMOTOR PROTECTION CIRCUIT BREAKERS
MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 7 safety contacts (N/O), instantaneous 2 auxiliary contacts (N/C),
More informationSingle-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
70 Series - Line monitoring relay 70 Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 5 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Connection
More informationIntroduction Circuit Protection
Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short
More informationOriginal operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016
Original operating instructions Safety relay with relay outputs with and without delay UK G50S 803638 / 00 0 / 06 Contents Preliminary note...4. Symbols used...4 Safety instructions...5 3 Items supplied...6
More informationSurge Protective Device
SURGE PROTECTIVE DEVICE Surge Protective Device 20 R 320 Type Max. discharge current Imax/Iimp (ka) Number of poles (P) R: with alarm auxiliary contact Blank: without alarm auxiliary contact Max. continuous
More informationOriginal operating instructions Safety relay with relay outputs G1501S / / 2016
Original operating instructions Safety relay with relay outputs G50S UK 8023637 / 00 02 / 206 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions
More informationMODULES FOR SAFETY AND MONITORING
MODULES FOR SAFETY AND MONITORING Woertz AG Hofackerstrasse 47, P.O. Box 948, CH-43 Muttenz, Switzerland Tel. ++4 6 / 466 33 33, Fax ++4 6 / 46 96 06 http://www.woertz.ch Woertz-USA 5 Discovery Drive,
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationCircuit Breakers Type CTI 25M, CTI 45MB
Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Block diagram Unit features Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors
More informationMonitor. Safety relay,etc. Contactor, etc. Uses external device monitoring function Note: Construct a separate reset input circuit.
Selectable safety circuits The light curtain unit has a built-in monitoring function for external devices (such as fused relay monitoring). This supports the construction of light curtain peripheral safety
More informationDescription. Installation. Power supply
Air circuit breakers Special versions Series MEGT07 0V/500V/DC 50 up to 5000 A The air circuit breakers MEGT07 are suitable for use as disconnecting switch in DC distributions up to a rated voltage of
More informationRUC-M industrial relays for DC loads
Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Min. breaking capacity
More informationSolid State Remote Power Controller E
Description The E-T-A is a transistorised switching device providing both protection and signalisation. It is suitable for all applications where the capabilities of the existing PLC s are not sufficient
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationSE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR
SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR AUGUST 14, 2001 REVISION 1 Publication: SE-135-M Document: S95-C135-00000 Printed in Canada. Copyright 2001 by Startco Engineering Ltd. All rights reserved.
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationQuick Start Guide TS A
Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer
More informationCircuit Breakers, Type CTI 25M, CTI 45MB, CTI 100
MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationSafe monitoring relays
Unit features Unit description Gertebild ][Bildunterschrift_Stillstandswchter Standstill monitor for safe standstill monitoring Approvals Zulassungen Gertemerkmale Positive-guided relay outputs: 2 safety
More informationMultifunctional time delay relay MFT U31S, MFT U41SE
8 Functions, 8 time ranges Multivoltage: 24 Vac / dc 110... 240 Vac 2 output contacts MFT U31S Functions E Delay on E Delay on - version with control contact as opening contact A Delay off without auxiliary
More information78 Series Electromechanical Relay Selection Guide
78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5
More informationPGM-8325 MANUAL NEUTRAL GROUNDING MONITOR
POWR-GARD Supplemental Monitoring PGM-8325 SERIES Neutral Grounding Monitor PGM-8325 MANUAL NEUTRAL GROUNDING MONITOR JULY 2, 2009 REVISION 10 F 1 CT1 CT2 A B L1 L2 GROUND FAULT 1.0 RESET RESISTOR FAULT
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 2 safety contacts (N/O), delay-on de-energisation
More informationInstallation manual EVA Start and Protected
Installation manual EVA Start and Protected 1 Introduction This document shows how to install and use the charge station EVA. There are three families of EVA models: EVA Connected, EVA Protected and EVA
More information2T105. Multi Range Digital Setting Time Delay Relay. Features. Application. Operation
2T15 Multi Range Digital Setting Time Delay Relay Technical Bulletin Features Four time ranges -.99s, -9.9s, -99s, -99s High accuracy & repeatability timing compensated for output relay delay Time settings
More informationD6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D
D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General
More informationS82S (3/7.5-W Models)
Switch Mode Power Supply (3/7.5-W Models) CSM DS_E_4_3 Miniature DIN Rail Mounting DC-DC Power Supplies 65 mm depth enables mounting onto control panels with 100 mm depth. Inputs: 10.2 to 27.6 VDC (DC
More informationOvervoltage Protection Devices
Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options
More informationINSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.
(INDIA) VT. LTD. 5. INCOMING SULY CONDUCTOR TERMINATIONS AND DEVICES FOR DISCONNECTING AND SWITCHING OFF 5.1 Incoming supply conductor terminations The electrical equipment of the machine shall have only
More informationWeathersafe Vision. Installation & Operating Instructions
Weathersafe Vision Installation & Operating Instructions IP66 Products covered by these instructions 1 TGVL01 TGVL02 TGVL03 TGVL05 TGV101N TGV201N TGV104N Single Gang 2-Way Switch [SP] 10AX (Fluorescent
More informationSIMOCODE 3UF Motor Management and Control Devices
Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient
More information