1 emerge Essential Access ontrol System Document Number: , Rev. Installation Guide Linear LL 1950 amino Vida Roble, Suite 150 arlsbad, A
2 Notices All rights strictly reserved. No part of this document may be reproduced, copied, adapted, or transmitted in any form or by any means without written permission from Linear LL. Standards Approvals This equipment has been tested and found to comply with the limits for a lass A digital device, pursuant to part 15 of the F Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. orporate Office Linear LL 1950 amino Vida Roble, Suite 150 arlsbad, A Tel: (800) / Fax: (800) / Technical Support Tel: (800) Hours: 5:00 AM to 4:30 PM Pacific Time, Monday - Friday 2
3 ontents 1.0 Introduction Access ontrol Overview emerge Overview Installation Overview hecklist ontrol Panel Layout ontrol Panel omponents Installing the ontrol Panel Mounting the emerge Essential Panel Mounting the emerge Essential Plus Panel System Power emerge Essential Power onnection emerge Essential Plus Power onnection PoE onnection Inputs and Outputs System Inputs Wiring the Inputs System Outputs Door Lock Outputs Readers Wiring the Readers Network onnection Preparing for the Network onnecting to the Network Troubleshooting
4 1.0 Introduction This manual contains information regarding the basic installation, wiring and configuration of the emerge Essential and emerge Essential Plus access control systems. The emerge Essential is enclosed in a space-efficient and durable plastic housing. The emerge Essential Plus is enclosed in a heavy-duty steel cabinet and features a self-contained battery back-up with a supervised power supply. Both systems use the same control panel layout and system wiring. Access ontrol Overview Access control systems are designed to monitor and control access throughout a building or restricted area. An access control system involves the use of an access device (card, PIN code, etc.), which is presented at an entry device (reader/keypad) to gain access. When access is granted, a door is unlocked for a pre-programmed amount of time and a transaction is recorded in a database for reporting or tracking purposes. emerge Overview The emerge Essential provides a browser-based one door, two reader access control system with immediate expansion capability to four doors, eight readers via an optional software license (P/N ES-1DL or ES-1DLB w/reader). The emerge Essential includes Ethernet support, an integrated web server and Power over Ethernet (PoE) support. Designed with efficiency in mind, the system is ideal for smaller commercial, industrial, banking, retail and restaurant access management applications; while offering scalability for growth. Specifications Processor On-board RAM Storage PIP Operating system Simultaneous system users 8 Transactions per second > 30 Plastic enclosure (W x H x D): Steel enclosure (W x H x D) Temperature specification ortex 1GHz 512MB DDR2 (333MHz) 4 GB Micro SD 12VD 60W UL Approved Embedded Linux in x 11.1 in x 2.23 in 31.1 cm x 28.2 cm x 5.7 cm 17.5 in x in x 6.4 in 44.5 cm x 61.6 cm x cm -20 F to 130 F (-28 to 54 ) Doors/Portals 1 (scalable to 4) Maximum readers 8 Inputs 12 Outputs 8 ard holders (users) 1,000 Access cards 8,000 ards per person 12 ard formats 32 Access levels 8 Time Schedules 100 Online transactions 15, emerge Essential Installation Manual
5 Note: The checklist provides a logical sequence for installing an emerge system; however, it is not necessary to follow this specific order. Installation Overview hecklist The following list presents the steps required for successfully installing an emerge Essential system. Mount the control panel onnect the readers onnect power to the panel Wire the inputs and outputs Obtain IP address and other TP/IP information from network administrator onfigure the emerge Essential s network settings (Optional) Add licenses for additional doors and readers onnect the emerge to a local area network (LAN) 5 emerge Essential Installation Manual
6 2.0 ontrol Panel Layout ontrol Panel omponents The following illustration shows the emerge control panel wiring and components. OUT READER 4 DOOR 4 ONTAT REX 4 IN READER 4 DOOR 3 OUT READER 3 ONTAT REX 3 IN READER 3 DOOR 4 LOK DOOR 3 LOK Buzzer DOOR 4 DOOR 3 AUX 1 AUX 2 AUX IN 1 AUX IN 2 LAN DL19 DL18 EARTH GROUND LEAD AUX 3 AUX 4 AUX IN 3 AUX IN 4 ETHERNET AUX RELAY 1 BANK AUX RELAY 2 AUX RELAY 3 AUX RELAY 4 DL17 DL16 DL15 DL14 DL13 DL12 DL11 DL10 DL9 RESET S2 S1 DL8 DL7 DL6 DL5 DL4 DL3 DL2 DL1 TMP - TMP + FLT - FLT + 12VD TAMPER PWR FAULT SD ARD SLOT JP1 D / 5A ( VA) DOOR 2 DOOR 1 JP1 - Power Input POE External D (Default) DOOR 2 LOK DOOR 1 LOK OUT READER 2 IN READER 2 OUT READER 1 IN READER 1 REX 2 DOOR 2 ONTAT REX 1 DOOR 1 ONTAT Figure 2.1. emerge Board Layout Table 2.1: Indicators ondition DL17 Red On = Power On Bottom Board DL9 Red On = Power On Middle Board DL1 Blue On = System is Rebooted DL1 to DL16 Blue On = System is Booting DL19, DL 18 Blue Blink = Network onnection TE: Boot up time is approx. 60 secs. Table 2.2: Default I/O States Attribute Default State Door Status Inputs Normally Open, Unsupervised, 8 Sec. Held Open Time REX Inputs Normally Open, Momentary, Unsupervised Auxiliary Inputs Normally Open, Unsupervised Door Lock Outputs Not Energized, Single Pulse, 3 Second Unlock Time Aux Outputs Not Energized, Single Pulse, 3 Seconds On 6 emerge Essential Installation Manual
7 3.0 Installing the ontrol Panel Note: This device complies with Part 15 of the F Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Mounting the emerge Essential Panel The emerge Essential housing is designed to accommodate the necessary wiring connections for most installations. Knock-outs are provided at the back-plate of the housing. The enclosure should be mounted in a secure location within normal temperature and humidity levels. Installing the Panel 1. Run all necessary wires to the panel location. 2. Remove the enclosure s cover by removing the two screws in the front of the housing. 3. Level the enclosure on a sturdy wall. Mark the mounting holes with a pencil. 4. Partially insert screws into the top two mounting holes and hang the enclosure on the screws. 5. Pull all wires through the knock-out holes in the enclosure. Label each wire according to its use. 6. Recheck for levelness, insert the two lower screws, and tighten all four mounting screws. Mounting Hole Enclosure Knockouts Note: hoose a centrally located, clean and dry area near an A power source. Avoid mounting the panel within 6 feet of any equipment that generates electrical interference. over Screw AUX IN 4 AUX IN 3 AUX IN 2 AUX IN 1 AUX RLY 4 DOOR 4 DOOR 3 ETHERNET EARTH GROUND LEAD over Screw AUX RLY 3 AUX RLY 2 aution: This equipment includes electronic components that are highly sensitive to static electricity. Please discharge by touching a ground before installing or handling this equipment. Enclosure Knockouts AUX RLY 1 DOOR 2 DOOR 1 TMP - TMP + FLT - FLT + 12VD over Tamper Figure 3.1. emerge Essential Enclosure 7 emerge Essential Installation Manual
8 Note: hoose a centrally located, clean and dry area near an A power source. Avoid mounting the panel within 6 feet of any equipment that generates electrical interference. Mounting the emerge Essential Plus Panel The emerge Essential Plus enclosure is designed to accommodate two 12VD 7Ah backup batteries and the necessary wiring connections for most installations. onduit knock-outs are provided on all sides of the enclosure. The enclosure should be mounted in a secure location within normal temperature levels. A minimum of 12 inches of space around all sides of the enclosure is recommended. Installing the emerge Essential Plus 1. Run all necessary wires to the panel location. 2. Remove the enclosure s cover by removing the front of the housing. 3. Remove the metal cabinet knock-outs required for wire entry. 4. Level the enclosure on a sturdy wall. Mark the mounting holes with a pencil. (The cabinet can be vertically or horizontally mounted depending on space requirements.) 5. Partially insert screws into the top two mounting holes and hang the enclosure on the screws. 6. Pull all wires through the knock-out holes in the enclosure. Label each wire according to its use. 7. Recheck for levelness, insert the two lower screws, and tighten all four mounting screws. aution: This equipment includes electronic components that are highly sensitive to static electricity. Please discharge by touching a ground before installing or handling this equipment. Mounting holes Tie wrap holders DOOR 4 abinet knockouts DOOR 3 over Tamper DOOR 2 DOOR 1 Power Supervision Module Figure 3.2. emerge Essential Plus Enclosure 8 emerge Essential Installation Manual
9 4.0 System Power Note: The emerge Essential housing will not accommodate a backup battery. If using a backup battery, a separate housing must be installed. aution: Improper power wiring will damage the fuse and void the warranty. The emerge Essential is powered using a 12VD / 5A plug-in-power supply (Linear P/N PIP-12VUR, not included). For UL listed installations, please use Linear P/N PIP-12V60W. The control panel may also be powered using an optional Power over Ethernet (PoE) injector (requires Linear PoE module, P/N ). emerge Essential Power onnection Power Supply onnection 1. onnect terminal 1 from the plug-in-power supply (PIP) to pin 1 (D) on the panel. 2. onnect terminal 3 from the PIP to pin 2 () on the panel. 3. onnect terminal 2 to the green earth ground lead provided in the enclosure. 4. Plug the PIP into a dedicated receptacle that is not controlled by a switch. 5. The PWR on the panel will illuminate to indicate that power is present. Note: Power should only be applied to the system when all connections are secured and tested. able Specifications for PIP: 14 AWG Belden (2 conductor) or equivalent. Maximum distance: 10 feet (3 meters). EARTH GROUND LEAD D PIP ( VA) TMP - TMP + FLT - FLT + 12VD 12VD Earth Figure 4.1. Power onnection 9 emerge Essential Installation Manual
10 Power Fault onnection The controller is equipped with a power fault input that can be utilized as follows: 1. Determine whether your power fault input device uses a normally closed or normally open configuration. Please refer to instructions provided by the manufacturer. 2. onnect the power fault input device to PIN 3 and PIN 4 on the terminal strip. 3. Apply power and verify that the power fault input device is functioning properly. TMP - TMP + FLT - FLT + 12VD Power Fault Input Figure 4.2. emerge Essential Power Fault onnection 10 emerge Essential Installation Manual
11 Note: The system will not power up using the backup battery. The 12VD PIP (P/N PIP-12V60W) or PoE (P/N ) must be present to power up the system. emerge Essential Plus Power onnection The emerge Essential Plus includes a factory installed power supervision module as shown in Figure 4.3. Power Supply onnection 1. onnect the D PIP (Linear P/N PIP-12V60W) to the red and black leads of the power supervision module. 2. onnect terminal 2 or 3 of the PIP to the green earth ground lead provided in the enclosure. 3. Plug the PIP into a dedicated receptacle that is not controlled by a switch. 4. The PWR on the panel will illuminate to indicate that power is present. 5. Place the 12VD backup battery in the cabinet. 6. onnect the red and black leads to the battery. Tamper Switch able Specifications for PIP: 14 AWG Belden (2 conductor) or equivalent. Maximum distance: 10 feet (3 meters). Earth Ground Lead TMP - TMP + FLT - FLT + 12VD Fault Output To 12VD PIP Figure 4.3. emerge Essential Plus Power onnection Note: The SD card slot (shown earlier in Figure 2.1) will backup panel memory in the absence of power or backup battery. Battery onnection The emerge Essential Plus provides charging and space for up to two 12VD/7Ah sealed lead-acid batteries. The battery provides standby power when the primary power source is lost. The control panel will utilize backup battery until the battery reaches 11VD at which point the entire system shuts down. Note: It is recommended to replace the system battery every 2 to 3 years emerge Essential Installation Manual
12 Note: The emerge Essential controller board consumes 200 ma of current at 12VD (2.4W). Note: The Linear PoE module (P/N ) must be installed in order to use a PoE injector (P/N POE-PLUS). To determine standby battery time: 1. Determine the total standby load of the system by adding the maximum and standby current draw of the devices connected to the panel. For example, if the system consists of the control panel (200 ma) and one 75 ma reader the total standby load is 275 ma (200 ma+ 75 ma). 2. Divide the total standby load by 1000 to convert it to amps. For example, 275 / 1000 = Divide the amp-hour rating of the battery by the total standby load to determine the standby time for the system. For example, 7.0 /.275 = 25.5 hours standby time using a 7 AH battery with a system that consists of the control panel and one 75 ma reader. Power Fault If A power loss is detected, the power supervision module will automatically switch to the backup battery and activate the fault input. The fault input can be configured via programming to activate a condition (dialer, etc.). The transaction will be logged in the history of the controller. Tamper Protection A tamper switch is mounted inside the enclosure and is pre-wired to the tamper input on the terminal strip. If the emerge Essential cover is removed for any reason the tamper switch will activate, triggering a condition that can be linked to an event action in programming (e.g., send an or generate an output). PoE onnection The emerge Essential can be powered using Power over Ethernet (PoE), which is a method for providing power via Ethernet cabling. To place the controller in PoE mode, move the Power Input Jumper to the left position as illustrated in Figure 4.4. A Power over Ethernet installation must consist of a high-power 30W PoE injector (P/N POE- PLUS) and the Liner E3-POE module (P/N ). Refer to the PoE module s installation guide for specific installation information. JP1 POE (Default) EXTERNAL 12VD Figure 4.4. Power Input Jumper 12 emerge Essential Installation Manual
13 5.0 Inputs and Outputs System Inputs The system has the capability of monitoring up to 4 door status inputs, 4 request to exit (REX) inputs, 4 auxiliary general purpose inputs and 2 digital inputs (reserved for future release). All inputs are assigned default features that can be configured as needed. The following table shows the default states for each of the inputs: Table 5.1: Default Input States Input Default State Door Status Inputs REX Inputs Auxiliary Inputs Normally Open, Unsupervised, 8 Second Held Open Time Normally Open, Momentary, Unsupervised Normally Open, Unsupervised Door Status Input The door status input monitors whether the door is in an open or closed state. A door status switch (typically a magnetic reed switch) will change states when the door is opened or closed. The door status input does not require any programming to enable. Simply connect a magnetic reed switch to the appropriate door input as shown in the control panel illustration, Figure 2.1. Request To Exit The Request to Exit (REX) input is a momentary input closure that activates the door output relay for the same amount of time as a valid card swipe or keypad entry. REX devices can include a press-toexit switch on the inside of a door or a passive infared detector (motion detector), which allows convenient egress. The REX input does not require any programming. Simply connect a normally open, momentary input device to the REX inputs as shown in the control panel illustration, Figure 2.1. Auxiliary Inputs The auxiliary inputs are general purpose inputs that can be used with a variety of input devices including O2 detectors, alarm system integration, etc. These inputs can be configured via programming to trigger a defined action such as to activate an output emerge Essential Installation Manual
14 Wiring the Inputs All inputs may be configured for normally open or normally closed contacts with supervision or non-supervision. Use standard 1k ohm resistors for supervision. Refer to Figure 5.1 for the acceptable wiring configurations. able Specifications: 22 AWG Belden or equivalent. Maximum distance: 2000 feet. SUPERVISED Resistor Value = 1k Ohm Normally Open UNSUPERVISED Normally Open Normally losed Normally losed Figure 5.1. Input ircuit onfigurations Tamper Protection (Emerge Essential) A tamper switch is mounted inside the enclosure for connection to pin 5 and pin 6 on the terminal strip. If the emerge Essential cover is removed for any reason the tamper switch will activate, triggering a condition that can be linked to an event action in programming (e.g., send an or generate an output). TMP - TMP + FLT - FLT + 12VD Factory Installed Tamper Figure 5.2. emerge Essential Tamper Input Wiring 14 emerge Essential Installation Manual
15 System Outputs The emerge Essential provides up to 4 door lock relays and 4 auxiliary output relays that may be activated in response to reader activity, time schedules or input conditions. All relays are Form- SPDT and provide non-powered dry contacts rated for 1A. Output Defaults All outputs are assigned default features that can be configured as needed. The following table shows the default states for each of the outputs: Table 5.2: Default Output States Output Default State Default Response Door Lock Outputs 1-4 Not Energized, Single Pulse 3 second unlock time in response to corresponding reader activity (Reader 1 activates door 1 lock relay) Aux Outputs 1-4 Not Energized, Single Pulse No default response. Must be configured via programming. Wiring Requirements The cable must be the proper gauge for the current load and should not be bundled with other wiring. Refer to the Table 5.3 for wiring recommendations: Table 5.3: Recommended Wiring Requirements Total Amps Voltage (A or D) Wiring Gauges and Distance A 1.00 A 2.00 A 3.00 A 12V 1500 ft 1000 ft 600 ft 375 ft 225 ft 24V 2000 ft 1200 ft 750 ft 450 ft 300 ft 12V 800 ft 500 ft 300 ft 200 ft 100 ft 24V 1000 ft 600 ft 400 ft 200 ft 150 ft 12V 400 ft 240 ft 150 ft 90 ft 60 ft 24V 480 ft 300 ft 180 ft 120 ft 70 ft 12V 260 ft 160 ft 100 ft 60 ft 24V 320 ft 200 ft 120 ft 15 emerge Essential Installation Manual
16 Buzzer Buzzer Buzzer DOOR 3 Door Lock Outputs The door lock outputs for doors 1 through 4 can be configured to operate in normally energized (fail-secure) or normally not-energized (fail-safe) modes. Wiring the Door Locks onnect locking devices to the door relay as shown in Figures 5.3 through 5.5. Refer to the door strike specifications to determine the appropriate voltage and configuration. WARNING: Do not use the control panel s power output for the locking device. An auxiliary power supply must be used. ETHERNET ONTROL PANEL S DOOR LOK RELAY aution: The diode or MOV must be installed as shown in the illustrations. Failure to install these protection devices may damage the control board. + D POWER SUPPLY - DIODE 1N4933 OR EQUIVALENT Figure 5.3. Fail Safe D Door Strike + - D DOOR STRIKE ONTROL PANEL S DOOR LOK RELAY TMP - TMP + FLT - FLT + D + D POWER SUPPLY - DIODE 1N4933 OR EQUIVALENT + - D DOOR STRIKE Buzzer Buzzer Figure 5.4. Fail Secure D Door Strike ONTROL PANEL S DOOR LOK RELAY A POWER SUPPLY MOV SNR-D56K2 OR EQUIVALENT Figure 5.5. Fail Safe A Door Strike A DOOR STRIKE NT 16 emerge Essential Installation Manual LOK
17 Door Lock Operation 1. Present a valid card/pin to a reader/keypad. 2. The controller will activate the door relay output associated with the particular reader (e.g., reader 1 will activate door lock relay 1). 3. The relay output is energized for a default time of 3 seconds. 4. As the user enters through the door, the door status input will change from closed to open. 6.0 Readers aution: Improper power wiring will damage the fuse and void the warranty. Wiring the Readers The control panel can accept up to 8 readers or keypads. Each reader port on the panel supports a 12VD reader with Wiegand output format. Readers can be installed as primary (entry) readers for each of the 4 doors as well as optional secondary (exit) readers. The maximum power available for each reader is VD. Determine the reader s power consumption by referring to the documentation included with the reader. Wiring Readers 1. Remove power from the control panel. 2. Pull the reader wiring through a knock-out in the panel s enclosure. 3. onnect the color-coded wires from the reader s wiring harness to the appropriate location of terminal strip as shown in Figure Remove excess shield to ensure that it is not exposed. An exposed shield can cause interference. Tape off any exposed shield with electrical tape. able Specifications: Twisted, shielded 22 AWG (250 ft.) or 18 AWG (500 ft.) Belden #9535 (5 conductor) or equivalent. Please follow manufacturers installation requirements. RED BRN GRN WHT BLK READER Figure 6.1. Reader Wiring 17 emerge Essential Installation Manual
18 7.0 Network onnection aution: The system is exposed to potential risks if installed on a network without proper security precautions. onsult the appropriate on-site IT administrator. Note: If a DHP server is present, IP Addresses are dynamically assigned. A static IP address is required for the controller because a DHP Server may assign a new IP Address resulting in loss of communication. The emerge Essential must be located in a trusted network environment where a protected network security system (firewall, etc.) is installed and maintained. Before you configure the controller please obtain the following information from your network administrator: IP address (if applicable) Subnet Mask Gateway DNS 1 and 2 Preparing for the Network To allow for the emerge Essential to be recognized on the local network, it is necessary to change the controller s IP address as follows: 1. onnect your programming computer directly to the Ethernet port of the control panel as shown in Figure 7.1. (You may also connect the computer and control panel to an Ethernet Switch.) LAN ETHERNET Figure 7.1. onnecting to the ontrol Panel 2. Assign a static IP address of to the computer. (For instructions on how to change the static IP address of a Windows computer, please visit: com/en-us/library/ff710457). 3. After assigning the static IP address, open a web browser and enter the IP address of the controller (Default = ). 4. The controller presents the emerge page as shown in Figure 7.2. To log on, enter the default user ID and password (admin/admin). Figure 7.2. Web Server Login Page 18 emerge Essential Installation Manual
19 3. Browse to the Network onfiguration page as shown in Figure 7.3. Enter the static IP address, Subnet Mask, Gateway and DNS server so that it matches the requirements of the local network. (Refer to the User Manual for complete programming information.) Figure 7.3. Network Settings Page 4. lick Save & Reboot and the system will reboot. 5. Disconnect the programming computer from the control panel. The emerge Essential is now ready for the local network. onnecting to the Network 1. Pull an Ethernet cable through the opening in the enclosure nearest the Ethernet port. 2. Plug the RJ-45 connector into the Ethernet port on the controller. 3. onnect to the local area network (LAN) as shown in Figure 7.4. able specification: AT 5 or better with an RJ-45 connector wired straight through to a network hub, switch or router. EMERGE Internet LAN Router lient omputer Figure 7.4. onnecting the emerge to a LAN 4. If the network connection is functioning properly, the LAN s on the control panel will illuminate as shown in Figure 7.5. The local computers will then be able to access the system by entering the IP address of the controller emerge Essential Installation Manual
20 LAN S DL19 DL18 ETHERNET Figure 7.5. emerge LAN s 8.0 Troubleshooting Programming the System The emerge Essential provides the ability to access and manage the system from a web browser on any local or remote computer. Refer to the User Programming Guide (P/N ) for programming and configuration instructions. Table 8.1: Troubleshooting the System Problem Solution The control panel does not power up. The control panel powers up but does not respond to card readers or inputs. No network communication exists with the control panel. How to reboot the system? How to clear the memory of the system and restore factory defaults? heck setting of JP1 on middle board (near input power connector) to ensure that the jumper is in the appropriate position for your desired power source. Measure input power for D If RED s are off, then input fuse may be blown. This fuse is not field-replaceable. Measure power at reader connectors. If no voltage is present, then reader fuse may be blown. Bring reader and/or input and connect directly at the panel. If it works at the panel, the wire run may be faulty. If LAN s are off or solid, then no physical network connection exists. heck network cabling. Verify the Subnet Mask, Gateway, DNS and IP address as provided by the network admin. Hardware Reboot system: Momentarily press switch S2 on middle board (near bank of 16 s). Press and Hold switch S1 for full 20 seconds on middle board (near bank of 16 s). You may also reboot and factory default the system using the GUI software. TE: If factory default, will need to re-enter license key and configure system. For further troubleshooting assistance, please visit the following online resources: Linear Technical Support: Tel: (800) ; Hours: 5:00 AM to 4:30 PM Pacific Time, M-F 20 emerge Essential Installation Manual opyright 2013 Linear LL
Access Control System Document Number: , Rev. D. Installation Guide. Essential Essential Plus Elite 36 Elite 64
Essential Essential Plus Elite 36 Elite 64 Access Control System Document Number: 620-100239, Rev. D Installation Guide USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800)
More informationQuick Start Guide. Mounting the Essential Plus and Elite
Quick Start Guide Congratulations on purchasing an Essential Plus or Elite access control system. This Quick Start Guide provides simple instructions on how to get the system up and running. For more detailed
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationMR51e Reader Interface
J4 J TB6 TB5 TB4 TB3 VIN VO TB2 TB J7 2.75 [69.85] 0.2 [5.08] 2.35 [59.69] J3 MR5e Reader Interface Installation and Specifications. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA
More informationgenesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010
Australian Owned, Designed and Manufactured Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products
More informationMR50 READER INTERFACE
2.75 [69.9] 2.35 [59.7] U1 MR50 READER INTERFAE Installation and Specifications: 1. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEAH, A 90815-1755, (562)986-9105 FAX (562) 986-9205 This device
More informationInstallation Guide. Avigilon ACM Embedded Controller
Installation Guide Avigilon ACM Embedded Controller 2016, Avigilon Corporation. Portions 2003-2014 HID Global Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER and ACM
More informationinstallation quick guide integrated access control & environmental monitoring
installation quick guide integrated access control & environmental monitoring Introduction This Installation Quick Guide is suitable for standard wallmountable AX300 controllers. Illustrative technical
More informationINSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3
INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: June, 2016 Version: 1.3 2 What s in the Box 2 Screws & Anchors 2 Screwdriver 4 Diode CONTENT Contents What s in the Box...2 Optional accessories...4
More informationgenesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured
Australian Owned, Designed and Manufactured Master Unit GEN-001 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products
More informationINSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:
INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA-675-001 Revision 1.0 Date Code: 1-1-2018 Table of Contents Table of Figures... 3 SPECIFICATIONS:... 4 INSTALLATION... 5 General:... 5 Physical Installation
More informationInstallation Instructions
Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line
More informationSecured Series: Hub Plus Kit Single Door Controller Package Installation Manual
Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationAX200. Installation Guide
Axxess Identification Ltd 27-28 Shrivenham Hundred Business Park, Watchfield, Swindon, Wiltshire SN6 8TZ United Kingdom Tel: +44 (0)1793 784002 Fax: +44 (0)1793 784005 Email: info@axxessid.com May 2008
More informationgenesis TECHNICAL MANUAL 16-Input Expander Unit GEN-010
16-Input Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationVertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1
15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...
More informationEP1501 Intelligent Controller
J6 BT K K2 TB5 TB 2.35 [59.69] 2.75 [69.85] EP50 Intelligent Controller with Paired Reader Interface for One Physical Barrier Installation and Specifications: www.mercury-security.com 2355 MIRA MAR AVE.
More informationSuprex RS-485 SPX-7500 Wired Reader-Extender
Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778
More informationCA-A480-A Elevator Controller. Reference & Installation Manual
CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................
More informationgenesis TECHNICAL MANUAL Two-Door Controller GEN-045
Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationINSTALLATION INSTRUCTIONS 921P EntryCheck TM
80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount
More informationQuick Installation Guide
9292 Jeronimo Road Irvine, CA 92618-1905 Quick Installation Guide V2000 READER INTERFACE / ACCESS CONTROLLER 2006 HID Global Corporation. All rights reserved Document Version 1.6 October 5, 2006 Document
More informationT775S Series 2000 Expansion Module
T775S Series 000 Expansion Module INSTALLATION INSTRUTIONS PRODUT DESRIPTION The T775S008 Relay Expansion Module is a four relay device for use with the T775L007 and T775P00 Series 000 Electronic Stand-Alone
More informationEP/2 Installation Instructions
1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in
More informationEncoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.
Encoder Firmware V4.06.09 User s Manual Outdoor PTZ Camera Hardware Manual KCM-8211 2013/05/09 1 Table of Contents Precautions... 3 Introduction... 4 List of Models... 4 Package Contents... 5 Safety Instructions...
More informationTruPortal Dual Door Interface Module Quick Reference
TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers
More informationSINGLE READER EXPANSION MODULE
SINGLE READER EXPANSION MODULE INSTALLATION GUIDE A D C - A C X 1 TR- SINGLE READER EXPANSION MODULE The ADC-ACX1 Single Reader Expansion Module provides a solution for interfacing to a one Wiegand reader
More informationLantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual
Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
More informationEN Series / EXN. Telephone Entry & Access Control System. Quick Start Guide (EN-2A4) ( EXN )
EN Series / EXN Telephone Entry & Access Control System (EN-2A4) ( EXN ) Quick Start Guide (P/N: EN-2A4 / EN-2M4, EN-2A7 / EN-2M7, EN-2A10 / EN-2M10, and EXN) NOTE: This Quick start guide is applicable
More informationistar Pro Installation Guide
istar Pro Installation Guide UM-241 Version A1 October 2010 istar Pro Installation Quick Start Guide System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general
More information1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing
The Keri NXT-6RK is a keypad reader typically used for card + PIN dual verification applications. It transmits keypad data in either 8-bit burst (default) or 26-bit Wiegand formats and can be used as a
More informationINSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B
INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM Doc. 6001051 Rev B Page 2 of 7 Doc 6001051 Rev B IMPORTANT NOTICES The Mini-Key system is a very reliable and easy to use system. However, damage could
More informationQuick Start Installation Guide
RM-DCM-2 Quick Start Installation Guide Version G0 Document Part Number UM-215 May 2010 OVERVIEW The RM-DCM-2 is a UL294 Listed and UL1076 Listed door control module that includes the RM-4E Reader Module
More informationUniversal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications
12 Universal Expander Module. Installation Notes. Revision 1.2 August. 2003. 1 Reporting Reporting with most Contact ID maps will treat the Mini Expander, Exp32 and Exp16 as the same. (With the exception
More informationGV-AS200 Controller. Hardware Installation Guide
GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.
More informationCA111x-series Arming Station
GE Security CA111x-series Arming Station Installation and Programming Guide Contents Page Product Overview...1 Removing the Covers...2 Mounting the RAS...3 Tamper Switch...3 DIP Switch Settings...3 Connections...4
More informationMR52 READER INTERFACE
IN IN2 IN3 IN4 INPUTS IN5 IN6 IN7 IN8 C www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 9085-755, (562)986-905 FAX (562) 986-9205 MR52 READER INTERFACE Installation and Specifications: This
More informationINSTALLATION INSTRUCTIONS 923P EntryCheck TM
801 Avenida Acaso, amarillo, a. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUTIONS 923P Entryheck TM The Entryheck 923P Indoor/Outdoor Keypad is a surface
More informationInstallation & Operation Guide
Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief
More informationStartup Guide. NetAXS-123. Version 5.2
NetAXS-123 Startup Guide Version 5.2 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)
More informationSmartLock Controller INSTALLATION MANUAL
SmartLock Controller INSTALLATI MANUAL November 2015 Table of Contents INTRODUCTI... 3 Diodes... 4 Terminal Strips and Cable... 5 SPECIFICATIS... 6 SMARTLOCK CTROLLER LAYOUT... 8 LED Indicators... 9 Mounting...
More informationQuick Start Installation Guide
RM-iCLASS Series Quick Start Installation Guide Version C0 Document Part Number UM-208 June 2009 OVERVIEW The RM-iClass Quick Start Installation Guide provides a summary of installation and connection
More informationINSTALLATION INSTRUCTIONS 920 EntryCheck TM
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount
More informationB-33. Hardware and Install Manual. (DC 12V / PoE)
B-33 Hardware and Install Manual (DC 12V / PoE) Table of Contents Precautions 3 Safety Instructions... 4 Introduction 6 Package Contents... 6 Physical Description... 7 Installation Procedures 9 Step 1:
More informationExpandable Power Systems
Expandable Power Systems Installation Guide Models Include: Maximal11EV 12VDC @ 4A or 24VDC @ 3A. 12VDC @ 4A or 24VDC @ 3A. Maximal33EV 12VDC or 24VDC @ 6A. 12VDC or 24VDC @ 6A. Maximal37EV 24VDC @ 10A.
More information2000 Series e/em Style Keypad Installation and Programming Manual
2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6
More informationINSTALLATION INSTRUCTIONS 920P EntryCheck TM
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount
More informationCT5000. Offline controller user guide Instructions for Adaptable Series offline controller _C LED2 USB USB SCHLAGE STRIKE RELAY STATUS +5V
TP2 TP22 TP23 TP24 TP25 ALR_ ALR_ ALR_N MLR VDD RB7 RB8 OPEN IDAT ILK RX 3.3V TX N N *P56-04* P56-04 T5000 Offline controller user guide Instructions for Adaptable Series offline controller J3 J S3 MOUNT
More informationVertX EVO V1000 Installation Guide Barranca Parkway Irvine, CA USA. July 2011 Document Number: Rev A.1
15370 Barranca Parkway Irvine, CA 92618 USA VertX EVO V1000 Installation Guide July 2011 Document Number: 71000-901 Rev A.1 Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable
More informationWiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:
Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact
More informationMS-5000: MiniStar Reader
The MS-5000 MiniStar Reader The MS-5000 MiniStar Reader is intended for installation in a single gang electrical "J-Box," in proximity applications where an unobtrusive reader is required. It can also
More informationINSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries
INSTRUCTION MANUAL DIGI-LOCK Keyless Entry System Installation Programming Troubleshooting BASE Industries 45 Pomona Rd. Corona, CA. 9880 Revision F TABLE OF CONTENTS OWNER REGISTRATION CARD INTRODUCTION
More informationBeacon Power Supply Operating and Installation Instruction Manual
Beacon Power Supply Operating and Installation Instruction Manual Model: BNx000 Page 1 of 27 I. Warnings and Notices I. WARNING - To reduce the risk of fire or electric shock, do not expose this product
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More informationTB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.
NXT x.0 Wiring and Layout Diagrams. NXT-x I/O Module Shielded CAT- Cabling Shielded -Conductor Cabling total cable length 00 feet max (0 m) Brown/Green/Orange w/o Stripe Brown/Green/Orange with Stripe
More informationTAC I/NETTM 1284, 1280, Security Control Unit
TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring
More informationSmartLock Pro INSTALLATION MANUAL
SmartLock Pro INSTALLATI MANUAL July 2010 Cutting edge simplicity Table of Contents INTRODUCTI... 3 Diodes... 3 Power Supply Notice... 3 Terminal Strips and Cable... 4 SPECIFICATIS... 5 SMARTLOCK CTROLLER
More informationMODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS
MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It
More informationInstalling Sentor. Hardware Installation
Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3
More informationNSD/M1 Installation Instructions
NSD/M1 Installation Instructions DOC. #560502200 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set forth in UL
More informationEntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation
The EntraGuard Bronze is a residential telephone keypad entry system which allows a homeowner to communicate directly with visitors and provide access by using any phone extension in the home. Because
More informationContents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection
Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection LAN Connection RS485 Connection Relay Connection Digital
More informationCustom Controller Installation Instructions
MODEL CUSTOM CONTROLLER HARDWARE CODE MAX ALLOWABLE AMBIENT TEMP: 70 C (158 F) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1) THIS DEVICE MAY
More informationFinger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot
Overview Fingerprint & Finger Vein Device Front Left Side: Finger Vein Device Touch screen Card reader Fingerprint reader Finger vein reader Finger vein sensor: During registration, after finger touches
More informationCRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09
CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.
More informationHome automation hub installation and setup guide
installation and setup guide is placed in a closed off area, the wireless signal strength may be compromised. Note: To prevent radio frequency (RF) interference, we recommend that you place the away from
More informationCardax FT Controller 3000
Installation Note Cardax FT Controller 000 CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any
More information0DQXIDFWXULQJ $FFHVV &RQWURO VLQFH
cdvigroup.com Copyright (C) 2011 CDVI. All rights reserved. ATRIUM Access Control is protected by copyright law and international treaties. Unauthorized reproduction or distribution of this product, or
More informationQUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control
QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.
More informationSecurity and Convenience Components 519H Three-Channel Receiver
Security and Convenience Components 519H Three-Channel Receiver FCC/ID Notice This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) This device may not
More informationPXL-250 Tiger Controller
PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and
More informationPIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board
*P516-097* P516-097 PIB300 and PIB301 User Guide Installation and operation instructions for Panel Interface Board Para el idioma español, navegue hacia www.schlage.com/support Pour la portion française,
More informationSOFTWARE VERSION 3.10
738PEP-03 SOFTWARE VERSION 3.10 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]
More informationPRT-RDS2 Standard 2 Reader Expander
PRT-RDS2 Standard 2 Reader Expander Installation Manual CONTENTS Protégé System... Introduction... Reader Expander... Features... Reader Expander Specifications... Protégé System Management Suite... Protégé
More informationMS-7000: SuperStar Reader
The MS-7000 SuperStar Reader The MS-7000 SuperStar Reader is intended for installation in proximity applications where an extended read range is required. The reader provides an audio beeper and a multi
More informationSuprex Ethernet SPX-7200 Ethernet Reader-Extender
Suprex Ethernet SPX-7200 Ethernet Reader-Extender Product Manual 1 SPX-7200_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems
More informationSPX Supervised Reader Extender. Wiring Diagram and Operators Manual MAN-FA-SPX-1200 V1.03
SPX-1200 Supervised eader Extender Wiring Diagram and Operators Manual MAN-FA-SPX-1200 V1.03 2005 ypress omputer Systems,Inc. www.cypressworld.com Page 1 Table of ontents Quick eference guides Page 3,4
More informationNETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel.
Revised! see Protective Earthing Addendum cback NOTE: This equipment must only be installed and serviced by professional qualified personnel. The Network Concentrator Link is a fully self contained unit
More informationBrivo Access Control System (ACS) Installation Manual DOCUMENT NUMBER ENG-DOC-003 ACS5000-E ENG-WI-001
Brivo Access Control System (ACS) Installation Manual DOCUMENT NUMBER ENG-DOC-003 ENG-WI-001 Legal Disclaimers Federal Communications Commission (FCC) Compliancy This equipment has been tested and found
More informationQuick Start Guide. GV-CS1320 Camera Access Controller
Quick Start Guide GV-CS1320 Camera Access Controller Thank you for purchasing GV-CS1320 Camera Access Controller. This guide is designed to assist the new user in getting immediate results from the controllers.
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More information4100/4120-Series and 4010ES Relay Modules Installation Instructions
4100/4120-Series and 4010ES Relay Modules Installation Instructions Introduction This publication describes the installation procedure for the relay cards listed in the following table. Model Number Description
More informationSPX-7400_SPX-7410_MAN_161028
Suprex Fiber Optic SPX-7400 & SPX-7410 Suprex Reader-Extender Data Sheet SPX-7400 Series EXP-2000 SPX-7400_SPX-7410_MAN_161028 1 Cypress Suprex SPX-7400 & SPX-7410 Overview The Suprex Fiber Optic SPX-7400
More informationInstallation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT
Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller,
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationCYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314
CYPRESS EXP-2000 SPX Expansion interface! modules The EXP-2000 provides additional Door/Panel interface points to most SPX products. The EXP-2000 uses a local RS-485 network through an SPX gateway device.
More information1.0 Wiring and Layout Diagrams
1.0 Wiring and Layout Diagrams 1.1 Reader Interface Module (RIM) NXT-RM Installation Drawing Reader Type Keri MS Reader - D4 Wiegand Reader - D5 NXT-6RK Keypad Reader - D6 Wiegand Combo Reader - D7 Step
More informationIPassan Installation guide
IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...
More informationInstallation Instructions 4291 and 4292 Keypads
Installation Instructions 4291 and 4292 Keypads A6851J 02/11 Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the
More informationInstallation Instructions for the AUTOcard-SA System
Installation Instructions for the AUTOcard-SA System IMPORTANT NOTICE The AUTOcard-SA system is a very reliable and easy to use system. However, damage could occur if it is installed incorrectly. In particular,
More informationACTpro Single Door IP Controller. Operating & Installation Instructions
ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control
More informationD12. 1MP Cube with Fixed lens Hardware User s Manual. (PoE) Ver. 2013/05/07
D12 1MP Cube with Fixed lens Hardware User s Manual (PoE) Ver. 2013/05/07 Table of Contents Precautions 3 Safety Instructions... 4 Introduction 6 Features and Benefits... 6 Package Contents... 7 Physical
More informationWiring Guide EP.HIO. Version 1.03 Last Updated:
Wiring Guide EP.HIO Version 1.03 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual Platform1 version 3 support 6 and 10
More informationPower Hub Cat. No. 83A00-1. Installation Manual WEB VERSION
Power Hub Cat. No. 83A00-1 Installation Manual WARNINGS AND CAUTIONS Read and understand all instructions. Follow all warnings and instructions marked on the product. Do not use this product near water
More informationINSTALLATION INSTRUCTIONS Model 930 EntryCheck
SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 930 EntryCheck
More informationSNAP-IT-1U Installation Guide
Chapter 1 SNAP-IT-1U Installation Guide Introduction The SNAP-IT rack-mount unit is a packaged solution for attaching electrical, electronic, and mechanical devices to an Ethernet network. Once attached
More informationSuprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502
Suprex Fiber Optic Reader-Extender SPX-7400 SPX-7410 Product Manual Reader-Extender Manual SPX-7400 Series EXP-2000 Suprex_FiberOptic_MAN_170502 Cypress Integration Solutions 30+ Years of Access Control
More informationWiring Guide EP.NMINI. Version 1.02 Last Updated:
Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass
More information