Operating instructions RFID evaluation unit DTE / / 2011
|
|
- Darlene Campbell
- 5 years ago
- Views:
Transcription
1 Operating instructis RFID evaluati unit DTE100 UK / / 2011
2 Ctents 1 Preliminary note Notes this document Symbols used Safety instructis General Installati and cnecti Tampering with the device Functis and features "PROFIBUS IN" and "PROFIBUS OUT" fieldbus interface "COM" cfigurati interface RFID antennas Requirements the Profibus DP master Functi Installati Installati distance Installati orientati Mounting optis Mounting DIN rail Removal Mounting plate Electrical cnecti AUX voltage supply Field bus cnecti PROFIBUS IN Profibus address Fieldbus cnecti PROFIBUS OUT Factory setting of the Ethernet parameters Process cnectis IO-1... IO Use as input/output to IEC Use with RFID read/write heads Functial earth cnecti Mounting DIN rail Mounting plate Operating and display elements
3 7.1 Reset to factory settings LED indicators LED AUX LED PROFIBUS LED COM LEDs IO1... IO Special device- LED indicatis Diagnosis Technical data...20uk 9.1 Data sheets Device manual Maintenance, repair and disposal Approvals/standards Scale drawing...21 Licences and trademarks Microsoft und Internet Explorer are registered trademarks of Microsoft Corporati. All trademarks and company names are subject to the copyright of the respective companies. 3
4 1 Preliminary note 1.1 Notes this document This document applies to the RFID evaluati unit DTE100. It is part of the device and ctains informati about the correct handling of the product. This document is intended for qualified electricians. These specialists are people who are qualified by their training and their experience to see and to avoid possible hazards that may be caused during operati of the device. Read this document before use to familiarise yourself with operating cditis, installati and operati. Keep this document during the entire durati of use of the device. 1.2 Symbols used Instructis > Reacti, result [ ] Designati of pushbutts, butts or indicatis Cross-reference Important note N-compliance can result in malfuncti or interference. Informati Supplementary note 2 Safety instructis 2.1 General Observe these operating instructis. Adhere to the warning notes the product. N-observance of the instructis, operati which is not in accordance with use as prescribed below, wrg installati or incorrect handling can affect the safety of operators and machinery. 2.2 Installati and cnecti The device must ly be installed, cnected and put into operati by a qualified electrician as the safe functi of the device and machinery is ly guaranteed when installati is correctly carried out.the installati and cnecti must 4
5 comply with the applicable natial and internatial standards. Respsibility lies with the pers installing the device. This is a class A product. The device may cause radio interference in domestic areas. In this case it can be necessary for the user to take appropriate measures. 2.3 Tampering with the device Tampering with the device is not allowed and will lead to an exclusi of liability and warranty. Tampering with the device can affect the safety of operators and machinery. Do not open the device. Do not insert any objects into the device. Prevent metal foreign bodies from penetrating. UK 3 Functis and features The RFID evaluati unit DTE100 integrates a Profibus DP interface and 4 channels for the cnecti of field devices. Each channel can be used either for the cnecti of an RFID antenna or as input/output to IEC The device ctrols the data exchange to the RFID antennas or the sensor/actuator level. communicates with the higher-level ctrol level via Profibus. allows device cfigurati via a web server. Applicati examples: Material flow ctrol in producti lines Warehouse management by the automatic detecti of stored products Tank management, order picking or product tracking 3.1 "PROFIBUS IN" and "PROFIBUS OUT" fieldbus interface Profibus DP-V0 / DP-V1 interface isolated from potential Baud rate 9600 baud to 12 Mbaud Max. distance between gateway and host: depending the baud rate max. 127 participants, 32 per segment 5
6 3.2 "COM" cfigurati interface 10 Mbps and 100 Mbps TCP/IP - Transport Ctrol Protocol/ Internet Protocol UDP - User Datagram Protocol IT functiality: HTTP server M12, twisted pair 3.3 RFID antennas The device supports up to four RFID read/write heads of type ANT51x from ifm electric gmbh. You can find informati about the matching read/write heads our website at: data sheet search ANT Requirements the Profibus DP master Profibus DP master of class 1 (DPM1) with DPV0 support or Profibus DP master of class 1 (DPM1) with DPV1 support (recommended) By using the DPV1 services the data size within the cyclically transferred input/output data of the Profibus DP master is csiderably reduced. 4 Functi You can find detailed informati about the functi of the system in the device manual at: data sheet search DTE100 Operating instructis 6
7 5 Installati 5.1 Installati distance Due to the internal heating of the device a minimum distance to other objects of 10 mm is to be taken into account during installati. UK A = 10 mm 5.2 Installati orientati The installati orientati can be freely selected. In a wet envirment upside-down mounting is not permitted. 7
8 5.3 Mounting optis Mounting DIN rail The device can be installed a DIN rail of type NS35/15 or NS35/ Angle the device and place the fixing clamp to the upper edge of the DIN rail. 2. Press device down. 3. Simultaneously rotate the device in the directi of the DIN rail Removal 1. Press device down. 2. Simultaneously rotate the device away from the DIN rail. 3. Remove the device from the top. 8
9 5.3.3 Mounting plate The device can be fixed to a mounting plate using 2 screws (M4 x 35 or lger). M4 M4 UK This installati mode is recommended for vibrati and shock requirements. 9
10 6 Electrical cnecti The device must be cnected by a qualified electrician. Discnect power before cnecting the device. Observe the natial and internatial regulatis for the installati of electrical equipment. Ensure voltage supply to EN 50178, SELV, PELV. Cnect the device according to the indicated pin cnecti. A total current csumpti of the device of 3 A must not be exceeded. Please note the following points to ensure protecti rating IP 67: Cover the unused sockets with protective caps. Tighten all protective caps and cnectors with a tightening torque of 1 Nm. You will find matching accessories at Accessories Protective cap Torque wrench ifm article number E73004 E AUX voltage supply Cnect the device to the voltage supply using an M12 cnecti cable. Pin Cnecti V DC 2 not used 3 0 V 4 not used 5 not used You can find matching cnecti cables at: data sheet search DTE100 Accessories 10
11 6.2 Field bus cnecti PROFIBUS IN Cnect the device to a Profibus DP master e.g. S7-315 DP using a suitable M12 Profibus cnecti cable Note: screened cnecti cable required Pin Cnecti 1 not used 2 RxD/TxD-N (bus A) 3 not used 4 RxD/TxD-P (bus B) 5 not used UK The following cnecti cables are recommended for use with the device: Descripti Cnecti cable, straight - angled Cable plug, straight Socket, straight ifm article number E12316, E12317 E12318, E12319 E12320, E Profibus address Profibus address delivery: 126 The address can be adapted via the integrated web server ( chapter 6.4) or a suitable Profibus DP master of class 1 or Fieldbus cnecti PROFIBUS OUT Cnect the device to the next Profibus DP participant using a suitable M12 Profibus cnecti cable. As an alternative: Cnect terminating resistor if the device is operated at the end of the Profibus DP line. 11
12 1 2 Pin 1 P5V Cnecti RxD/TxD-N (bus A) 3 DGND Note: screened cnecti cable required 4 RxD/TxD-P (bus B) The following terminating resistor is suitable for use with the device: Descripti Terminating resistor ifm article number E12315 Ethernet cnecti COM The device features an Ethernet interface for parameter setting and diagnosis. The settings are made via a web browser, e.g. Microsoft Internet Explorer as from V7.0. Cnect the device to a PC using a suitable M12 Ethernet cnecti cable. 1 2 Pin Cnecti 1 TD RD+ 3 TD- Note: screened cnecti cable required 4 RD- The following cnecti cable is suitable for use with the device: Descripti Ethernet cnecti cable M12 / RJ45 ifm article number E Factory setting of the Ethernet parameters The following values are preset delivery of the device: 12
13 Parameters Factory setting IP address Gateway address Subnet mask Auto-negotiati 6.4 Process cnectis IO-1... IO-4 Each process cnecti can be used as input/output to IEC or for cnecti of an RFID read/write head. The cnectis are set via the hardware cfigurati of the Profibus DP master. UK Pin Cnecti L+ 2 switching input (I/Q) 3 L- 4 switching output (C/Qo) or input (C/Qi) 5 not used The evaluati unit has to be discnected before field units are cnected. Please note that the total current csumpti of the device must not exceed the value of 3 A Use as input/output to IEC Ensure the following settings in the Profibus master: Applicati Example Cfigurati in the Profibus DP master Input sensor input Output actuator output 13
14 6.4.2 Use with RFID read/write heads There are various operati modes when an RFID read/write head of type ANT51x is cnected: Operating mode Acyclic executi of commands via PIB Read UID from tag or write UID to tag Cyclic executi of commands Cfigurati in the Profibus DP master PIB state RWH UID RWH STRG You can find detailed informati about the available operating modes in the device manual at: data sheet search DTE100 Operating instructis 14
15 6.5 Functial earth cnecti. To ensure trouble-free operati the device must be cnected to an earth potential free from external voltage Mounting DIN rail The cnecti is made automatically via the DIN rail. Note that the DIN rail must be cnected with the earth potential. UK Mounting plate When the device is fixed a mounting plate, cnecti is made via the left fixing screw. Note that the plate must be cnected with the earth potential. 15
16 7 Operating and display elements 7.1 Reset to factory settings Profibus address and Ethernet parameters can be reset to the factory settings. Take the following steps: Remove all cable cnectis from the device. Insert an electrically cductive bridge between pin 1 and pin 3 the process cnecti IO-3. Cnect device with the voltage supply and wait until the yellow LED indicati AUX and IO-3 flashes at approx. 8 Hz. Discnect the device from the voltage supply and cnect it again. > > The settings are reset. 7.2 LED indicators The device indicates the current status of the interface via the status LEDs LED AUX LED green LED yellow Status Note off off no voltage supply U AUX < 5 V flashes at 2 Hz voltage supply too low 5 V U AUX 18 V off voltage supply OK 18 V U AUX 36 V flashes at 8 Hz voltage supply too high U AUX > 36 V 16
17 7.2.2 LED PROFIBUS LED red LED green Status Note off off flashes at 2 Hz no cnecti to the Profibus DP master cnecti to Profibus DP master exists, no cyclical data exchange cnecti to the Profibus DP master exists, cyclical data exchange running Profibus DP protocol stack in the device does not run or no cnecti to the DP master device is in the "WAIT_PRM" or "WAIT_CFG" state device is in the "DATA_EXCH" state" UK LED COM LED green LED yellow Status Note off off off flashes sporadically no cnecti to another Ethernet counterpart cnecti to Ethernet counterpart exits, no data exchange cnecti to Ethernet counterpart exists, data exchange running link status "no link" link status "link", "no traffic" link status "link", "traffic" 17
18 7.2.4 LEDs IO1... IO4 The LED indicatis of the process cnectis differ with each cnecti cfigurati. Use as input to IEC LED green LED yellow Status Note off off interface deactivated interface in DP master not cfigured off interface activated, input L level (0 V) - interface activated, input H level (24 V) - flashes at 8 Hz flashes at 8 Hz overload or short circuit - Use as output to IEC LED green LED yellow Status Note off off interface deactivated interface in DP master not cfigured off interface activated, output L-active (0 V) - interface activated, output H-active (24 V) - flashes at 8 Hz flashes at 8 Hz overload or short circuit - 18
19 Use with RFID read/write heads LED green LED yellow Status Note off off interface deactivated flashes at 2 Hz flashes at 8 Hz off off flashes at 8 Hz interface activated, antenna off interface activated, tag not in the field interface activated, tag in the field overload, short-circuit or communicati error interface in DP master not cfigured UK Special device- LED indicatis LED Status Note green AUX LED yellow AUX LED flashes at 8 Hz yellow IO1...IO4 LEDs flash at 8 Hz green AUX LED yellow AUX LED flashes at 8 Hz green IO1...IO4 LEDs flash at 8 Hz yellow IO1...IO4 LEDs flash at 8 Hz Device is in the service mode "emergency system started". Major error, device has to be returned. A firmware update is necessary and can be executed via the web server. Hardware fault or permanent data in the device are corrupt. 19
20 LED Status Note green AUX LED yellow AUX LED flashes at 8 Hz Reset to factory settings - yellow IO3 LED flashes at 8 Hz 8 Diagnosis Errors occurring during operati can be evaluated via the Profibus DP diagnostics and via the LED status indicatis (chapter 7). 9 Technical data 9.1 Data sheets Data sheets can be found at: data sheet search DTE Device manual The device manual can be found at: data sheet search DTE100 operating instructis 10 Maintenance, repair and disposal Dispose of the device in accordance with the natial envirmental regulatis. 11 Approvals/standards The EC declarati of cformity and approvals can be found at: data sheet search DTE100 Approvals 20
21 12 Scale drawing 85 46, ,2 UK M12x1 M4 57,5 115 M12x1 43,5 21
Operating instructions RFID evaluation unit DTE / / 2016
Operating instructions RFID evaluation unit DTE101 80005398 / 01 06 / 2016 Contents 1 Preliminary note...4 1.1 Notes on this document...4 1.2 Symbols used...4 2 Safety instructions...4 2.1 General...4
More informationOperating instructions AS-i SmartLine module AC3200 AC /00 06/2016
Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target
More informationInstallation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010
Installation instructions RF-identification system with integrated AS-i slave UK DTSLF 704153 / 07 04 / 2010 Inhalt 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 2.1 General...4
More informationFlow monitoring For the connection of intrinsically safe flow sensors IO-Link device with relay outputs FMX-IM-3UR38X
Associated equipment [Ex ia Ga / Da] Cnecti of flow probes Ze 0 / 20 For Ex ia resp. Ex ib sensors Relay output for flow, temperature and faults Adjustment of switchpoint, no teaching of flow boundaries
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationOriginal operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016
Original operating instructions Fail-safe SmartPLC with Profinet slave interface AC402S UK 80237419/00 06/2016 Contents 1 Preliminary note...4 1.1 Notes on this document...4 1.2 Symbols used...4 2 Safety
More informationBrief instructions Mobile 3D sensor O3M150 O3M151 O3M160 O3M /00 03/2016
Brief instructions Mobile 3D sensor O3M150 O3M151 O3M160 O3M161 80236592/00 03/2016 Content 1 About these instructions........................................... 4 1.1 Symbols used...............................................
More informationOperating instructions Evaluation system for flow sensors VS / / 2013
Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...
More informationOperating instructions. Speed monitor D / / 2014
Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationInstallation instructions Ethernet switch EC / / 2011
Installation instructions Ethernet switch EC2095 7390731 / 00 02 / 2011 Contents 1 Preliminary note................................................. 3 1.1 Symbols used...............................................
More informationOperating instructions IO-Link master CabinetLine AL19xx
Operating instructions IO-Link master CabinetLine AL19xx 80273036/00 02/2018 1 Preliminary note Technical data, approvals, accessories and further information at www.ifm.com. 2 Safety instructions Read
More informationQuick reference guide 3D sensor O3D3xx
Quick reference guide 3D sensor O3D3xx 80271080 / 00 11 / 2017 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...4 2.1 Safety note...4 3 Functions and features...4
More informationOperating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015
Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC5294 80226775/00 02/2015 Contents 1 Preliminary note...3 2 Safety instructions...3 3 Functions
More informationOperating instructions Encoder PerformanceLine. RxP5xx /00 04/2018
Operating instructions Encoder PerformanceLine RxP5xx UK 706393/00 04/208 Contents Preliminary note...4. Notes on this document...4.2 Symbols used...4 2 Safety instructions...4 2. General...4 2.2 Installation
More informationDevice manual Profibus encoder. RM30xx RN30xx /00 06/2013
Device manual Profibus encoder RM30xx RN30xx 706355/00 06/2013 Contents 1 Preliminary note................................................. 4 1.1 Symbols used...............................................
More informationOperating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015
Operating instructions Diagnostic electronics for vibration sensors VSE00 / VXE00 / VXE00 VYE00 / VYE00 / VYE00 / VYE0 80677/0 05/05 Contents Preliminary note... Safety instructions... Functions and features...
More informationOperating instructions Optical distance sensor. OID20x / / 2015
Operating instructions Optical distance sensor OID20x 80228367 / 00 03 / 2015 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More informationOperating instructions Optical distance sensor. OID25x / / 2015
Operating instructions Optical distance sensor OID25x 80228366 / 00 03 / 2015 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4
More informationInstallation instructions Diagnostic electronics for vibration sensors VSE / / 2007
Installation instructions Diagnostic electronics for vibration sensors UK VSE00 70406 / 00 07 / 2007 Contents Safety instructions 3 Function and features 4 Mounting 4 Mounting of the sensors 5 Electrical
More informationManual Electronic Identification Systems BIS Processor BIS L-60_2 Profibus DP L60_2-019_828132_0304-e.p65 Deutsch bitte wenden!
1 Manual lectric Identificati Systems BIS Processor BIS L-60_2 Profibus DP Deutsch bitte wenden! 2 No. 828 132 D/ diti 0304 Subject to modificati. Replaces editi 0303 2 http://www.balluff.de Balluff GmbH
More informationOperating instructions. Monitor FD / / 2013
Operating instructions Monitor FD-1 UK 7390956 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationInstallation instructions Inclination sensor EC2019 EC / / 2013
Installation instructions Inclination sensor UK EC219 EC245 739215 / 3 1 / 213 Inhalt 1 Safety instructions 3 2 Mounting 4 3 Electrical connection 4 4 Dimensions 4 5 Technical Data 5 6 Characteristics
More informationOriginal operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016
Original operating instructions Safety relay with relay outputs with and without delay UK G50S 803638 / 00 0 / 06 Contents Preliminary note...4. Symbols used...4 Safety instructions...5 3 Items supplied...6
More informationUniversal digital indicator 4½-digit
SENSORS FOR FOOD AND BIOPHARMA. Product Informati PEM-UC CONTROLS Universal digital indicator ½-digit Applicati/specified usage Machine and switch cabinet cstructi Indicating and transforming of process
More informationOperating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017
Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC5274 7390889/00 07/2017 Contents 1 Functions and features...3 2 Operating and display elements...3 3 Installation...4
More informationDevice manual Inclination sensor 2 axes JN /00 04/2015
Device manual Inclination sensor 2 axes JN2301 80228166/00 04/2015 Contents 1 Preliminary note................................................. 4 1.1 Symbols used...............................................
More informationOperating instructions Optical distance sensor. OID25x / / 2014
Operating instructions Optical distance sensor OID5x 70608 / 01 08 / 01 Contents 1 Preliminary note... 1.1 Symbols used... Safety instructions... Functions and features....1 Applications... Installation...5.1
More informationOperating instructions. Monitor FS-2 / FS-2N / / 2013
Operating instructions Monitor FS-2 / FS-2N UK 7390959 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target
More informationBrief instructions Illumination unit O3M950 O3M /00 03/2016
Brief instructions Illumination unit O3M950 O3M960 80236594/00 03/2016 Content 1 About these instructions........................................... 4 1.1 Symbols used...............................................
More informationOperating instructions Optical distance sensor. OID20x / / 2014
Operating instructions Optical distance sensor OID0x 800005 / 00 08 / 01 Contents 1 Preliminary note... 1.1 Symbols used... 1. Warning signs used... Safety instructions... Functions and features...5.1
More informationSupplementary device manual AS-i controller e with Profibus DPV1 A AC1355, AC1356 AC1365, AC1366
Supplementary device manual AS-i controller e with Profibus DPV1 A AC1355, AC1356 AC1365, AC1366 AS-i master profile: M4 Firmware: from version RTS 3.0 onwards Target: from V.15 onwards for CoDeSys from
More informationDevice manual Diagnostic electronics with PROFINET-IO interface for vibration sensors VSE150
Device manual Diagnostic electronics with PROFINET-IO interface for vibration sensors VSE150 80257046/00 10/2017 Contents 1 Preliminary note................................................. 4 1.1 Explanation
More informationOperating instructions Memory plug E /02 11/2011
Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5
More informationOperating instructions Optical distance sensor O1D / / 2008
Operating instructions Optical distance sensor O1D155 UK 704391 / 01 11 / 2008 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 3 Functions and features...5 3.1 Applications...5
More informationOriginal operating instructions Safety relay with relay outputs G1501S / / 2016
Original operating instructions Safety relay with relay outputs G50S UK 8023637 / 00 02 / 206 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions
More informationDevice manual Supplement. S7 library for evaluation unit DTE / / 2012
Device manual Supplement S7 library for evaluation unit DTE100 706146 / 00 04 / 2012 Contents 1 Preliminary note................................................. 3 1.1 Symbols used...............................................
More informationAL-DMX-Switch wall dimmer with DMX output
AL-DMX-Switch wall dimmer with DMX output Atx Led Csultants Inc 815-A Brazos #326 Austin Tx, 78701 512 377 6052 http://atx-led.com Product Descripti - AL-DMX-Switch This switch operates just like any standard
More informationSK TU4-PBR Part number:
SK TU4-PBR Part number: 275 281 100 PROFIBUS DP External Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their
More informationOperating instructions Optical distance sensor. O5D15x / / 2014
Operating instructions Optical distance sensor O5D15x 706307 / 01 08 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4
More informationBNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide
BNI PBS-502-001-Z001 IP67 module, Profibus IO-Link Master Short Guide 1 Notes for the User 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typografical conventions 2 1.3.1 Enumerations 2 1.3.2
More informationInstallation Guide. O2Vxxx / / 2015
Installation Guide O2Vxxx 706371 / 01 10 / 2015 Contents 1 Preliminary note................................................. 4 1.1 Symbols used............................................... 4 1.2 Warning
More informationOriginal operating instructions Fail-safe inductive sensor GF711S / / 2013
Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding
More informationOperating instructions. ProcessLine analogue module AC / / 2012
Operating instructions ProcessLine analogue module AC2916 739089 / 01 06 / 2012 Contents 1 Safety instructions... 3 2 Functions and features... 4 3 Operating and display elements... 4 4 Electrical connection...
More informationOperating instructions ClassicLine module AC / / 2012
Operating instructions ClassicLine module AC0 UK 79079 / 0 06 / 0 Contents Safety instructions... Functions and features... Operating and display elements... Installation... Addressing... 9. Addressing
More informationSmartWire-DT Modules IP67
Manual 05/15 MN120006EN SmartWire-DT Modules IP67 All proprietary names and product designations are brand names or trademarks registered to the relevant title holders. Break-Down Service Please call your
More informationOperating Instructions IO-Link Master with Modbus TCP interface DataLine 8 Ports IP 65 / IP 66 / IP 67 AL1342
Operating Instructions IO-Link Master with Modbus TCP interface DataLine 8 Ports IP 65 / IP 66 / IP 67 AL1342 IO-Link: 1.1.2 ifm firmware: 2.1.28 or higher LR DEVICE: 1.3.1.x or higher English 7391206
More informationOperating instructions RFID read/write head with IO-Link DTIxxx
Operating instructions RFID read/write head with IO-Link DTIxxx 706470 / 00 04 / 2018 Contents 1 Preliminary note................................................. 4 1.1 Symbols used...............................................
More informationDM20C. LB2 I/O Series Module with 10 Digital input, 10 High Side output 5Khz Counter module. Data Sheet Doc: v1.01 / December 17 th, 2018
DM20C LB2 I/O Series Module with 10 Digital input, 10 High Side output 5Khz Counter module Data Sheet Doc: 40404 v1.01 / December 17 th, 2018 Ctents INTRODUCTION to LB2 I/O series... 3 IO MODULE BACKPLANE
More informationOperating Instructions IO-Link Master with EtherNet/IP interface DataLine 4 Ports IP 65 / IP 66 / IP 67 AL1320
Operating Instructions IO-Link Master with EtherNet/IP interface DataLine 4 Ports IP 65 / IP 66 / IP 67 AL1320 IO-Link: 1.1.2 ifm firmware: 2.1.28 or higher LR DEVICE: 1.3.1.x or higher English 7391156
More informationBrief instructions Illumination unit O3M /00 09/2014
Brief instructions Illumination unit O3M950 80222824/00 09/2014 Content 1 About these instructions........................................... 4 1.1 Symbols used...............................................
More informationOperating instructions Optical distance sensor O1D / / 2012
Operating instructions Optical distance sensor O1D106 UK 704204 / 01 08 / 2012 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...4 3 Functions and
More informationOperating instructions Electronic pressure sensor PN7xxx
Operating instructions Electronic pressure sensor PN7xxx 8000579 / 00 08 / 208 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...4 3 Functions and features...5 3. Applications...5
More informationOperating instructions. Monitor FR-1 / FR-1N / / 2013
Operating instructions Monitor FR-1 / FR-1N UK 7390953 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target
More informationOriginal operating instructions Fail-safe inductive sensor GI711S / / 2010
Original operating instructions Fail-safe inductive sensor GI7S 704583 / 0 06 / 200 Contents Preliminary note 3. Explanation of symbols 3 2 Safety instructions 4 2. Safety-related requirements regarding
More informationRAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description
I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules
More informationSK CU4-EIP-C Part number:
SK CU4-EIP-C Part number: 275 271 519 EtherNet/IP Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their
More informationOperating instructions IO-Link INLINE DISPLAY 1.44" E30430
Operating instructions IO-Link INLINE DISPLAY 1.44" E30430 UK 80235800 / 00 02 / 2017 Contents 1 Safety instructions...2 2 Functions and features...3 3 Function...4 4 Installation...4 5 Electrical connection...4
More informationLighting Controller. Data HUB YDHUB4 YDHUB4O YDHUB4OP LED Lighting Systems Installation Manual. (Version 1.3)
Lighting Ctroller Data HUB YDHUB4 YDHUB4O YDHUB4OP LED Lighting Systems Installati Manual (Versi 1.3) YESCO LLC, 5119 South Camer Street, Las Vegas, NV 89118 DMX Data Hub User Guide (Versi 1.3) Table of
More informationOperating instructions Electronic pressure sensor. PN72xx PN73xx PN76xx / / 2016
Operating instructions Electronic pressure sensor PN72xx PN73xx PN76xx 8002464 / 00 07 / 206 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...4 3 Functions and features...5 3. Applications...5
More informationSupplementary device manual EtherCAT interface in the AS-i controllere A AC1391 AC1392
Supplementary device manual EtherCAT interface in the AS-i controllere A AC1391 AC139 firmware version RTS.x target from 15 for CoDeSys from version.3 English 739071_00_UK 01-0- Contents Revision: 16 December
More informationSK CU4-PNT-C Part number:
SK CU4-PNT-C Part number: 275 271 515 PROFINET IO Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their
More informationDevice manual Inclination sensor 2 axes. JN2301 from firmware /00 05/2016
Device manual Inclination sensor axes JN30 from firmware.3.0 8054503/00 05/06 Contents Preliminary note................................................. 4. Symbols used...............................................
More informationOperating instructions Pressure sensor. PN50xx / / 2010
Operating instructions Pressure sensor PN50xx 704789 / 00 05 / 2010 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 4 Function...5 4.1 Processing
More informationBNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide
BNI PBS-104-000-Z001 BNI PBS-302-000-Z001 BNI PBS-501-000-Z001 BNI PBS-502-000-Z001 Short Guide English 1 2 3 4 Notes to the User 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical
More informationSK CU4-PBR-C Part number:
SK CU4-PBR-C Part number: 275 271 500 PROFIBUS DP Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their
More informationSK TU4-CAO-C Part number:
SK TU4-CAO-C Part number: 275 281 151 CANopen External Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their
More informationOperating Instructions IO-Link Master with EtherNet/IP interface StandardLine 4 Ports IP 65 / IP 66 / IP 67 AL1120
Operating Instructions IO-Link Master with interface StandardLine 4 Ports IP 65 / IP 66 / IP 67 AL1120 IO-Link: 1.1.2 ifm firmware: 2.1.28 or higher LR DEVICE: 1.3.1.x or higher English 7391219 / 01 05
More informationSystem manual AS-i safety monitor AC041S /00 05/2013
System manual AS-i safety monitor AC041S UK 7390926/00 05/2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions and features...6 5 Structure
More informationOriginal operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS
Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS UK 704818 / 01 10 / 2016 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning
More informationUser Guide. intouch HB_EN_inTouch Rev. ST4-A 07/17. Service Software for the product family FISCHER intouch * *
User Guide intouch 09005965 HB_EN_inTouch Rev. ST4-A 07/17 *09005965* Service Software for the product family FISCHER intouch Masthead FISCHER Mess- und Regeltechnik GmbH Manufacturer: Technical editorial
More informationOperating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO
Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...
More informationFIELDBUS TECHNOLOGY ETHERNET- PROFIBUS- INTERFACE PB-XEPI F1144/ 03 INSTALLATION MANUAL
FIELDBUS TECHNOLOGY ETHERNET- PROFIBUS- INTERFACE PB-XEPI INSTALLATION MANUAL F1144/ 03 2 Installation PB-XEPI D301144 0509 Content About this "Installation manual"...5 Intended use...5 Explanation of
More informationOperating instructions AC010S Compact AS-i E-STOP safety module
Operating instructions AC010S Compact AS-i E-STOP safety module Sachnr. 7390636_/00 05/2007 Contents Safety instructions............................. 3 Installation / Setup............................
More informationDevice manual Field modules DP AC2630 / AC2631 / AC2634 AC2636 / AC2637 / AC / / 2013
Device manual Field modules DP AC2630 / AC2631 / AC2634 AC2636 / AC2637 / AC2638 7390983 / 00 03 / 2013 Contents 1 Preliminary note................................................. 4 2 Safety instructions...............................................
More informationOperation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit
Fieldbus system PROFIBUS DP Compatible GW unit Operation Manual EX50-GPR URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8 3-507-89 Fax: +8 3-598-536
More informationOperating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E
Operating Instructions (Compact) 1 SIMATIC Industrial PC Release 11/2006 A5E00344128-04 Siemens Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety,
More informationXPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name
Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
More informationBNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide
BNI PBS-104-000-Z001 BNI PBS-102-000-Z001 BNI PBS-302-000-Z001 Quick start guide Content 1 Notes for the User 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typografical conventions 2 1.3.1 Enumerations
More informationOperation Manual Profibus DP -Display HE 5120 P with digital I/O's
Operation Manual Profibus DP -Display HE 510 P with digital I/O's "HESCH" Schröder GmbH Boschstraße 8 31535 Neustadt Telefon +49 (0) 503 / 9535-0 Telefax +49 (0) 503 / 9535-99 e-mail: info@hesch.de http://www.hesch.de
More informationOperating instructions Binary level sensor LMC / / 2014
Operating instructions Binary level sensor LMC502 80224249 / 00 12 / 2014 Content 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...3 3.1 Applications...3
More informationRAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description
I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless
More informationContent. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2
Content Content... 2 1. Preliminary note... 3 1.1. Symbols used... 3 1.2. Warning signs used... 3 2. Safety instructions... 4 2.1. General... 4 2.2. Target group... 4 2.3. Electrical connection... 4 2.4.
More informationDI20C. LB2 I/O Series Digital input & High Speed 5kHz counter. Data Sheet Doc: v1.01 / December 17 th, 2018
DI20C LB2 I/O Series Digital input & High Speed 5kHz counter Data Sheet Doc: 40401 v1.01 / December 17 th, 2018 Ctents INTRODUCTION to LB2 I/O series... 3 IO MODULE BACKPLANE PART... 3 VERSIONS / ORDERING
More informationOriginal Programming Manual Fail-safe SmartPLC AC4S with fieldbus interfaces AC402S AC422S
Original Programming Manual Fail-safe SmartPLC AC4S with fieldbus interfaces AC402S AC422S for ISO 13849 up to PL e for IEC 61508 SIL 3 and 62061 up to SIL CL 3 Firmware: 4.0.2 CODESYS Development System:
More informationQUICK START GUIDE IC-KP2-*
FACTORY AUTOMATION QUICK START GUIDE IC-KP2-* IDENTControl Compact control interfaces With regard to the supply of products, the current issue of the following document is applicable: The General Terms
More informationSCHMIDT Sensor interface PROFIBUS Instructions for use
SCHMIDT Sensor interface PROFIBUS Instructions for use Table of contents 1 Important information... 3 2 Intended use... 4 3 Electrical connection... 4 4 Signalizations... 7 5 Startup... 9 6 Technical data...
More informationBU 0220 GB. Intelligent Drivesystems, Worldwide Services SUPPLEMENTARY MANUAL BU 0220 GB PROFIBUS DP FOR FREQUENCY INVERTER NORDAC SK 200E
Intelligent Drivesystems, Worldwide Services SUPPLEMENTARY MANUAL BU 0220 GB PROFIBUS DP FOR FREQUENCY INVERTER NORDAC SK 200E Illustration of devices with options BU 0220 GB Getriebebau NORD GmbH & Co.
More informationProfibus-DPV1 Set in IP67 TI-BL67-DPV1-6
Type designation Ident no. 1545030 Number of channels 6 Dimensions (W x L x H) 172 x 145 x 77.5 mm Cable max. 50 m between interface and read/write head 3 decimal rotary coding switches for the adjustment
More informationOriginal operating instructions Fail-safe inductive sensor GI712S
Original operating instructions Fail-safe inductive sensor GI712S 80236527 / 00 12 / 2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...4 2.1 Safety-related
More informationSiemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4
Preface 1 Scope of Delivery 2 Product Characteristics 3 Industrial I/O-Node ION PROFIBUS DP SPY T001 Installation and Maintenance 4 6AT8000-1BA00-5XA0 Notes on the CE Mark 5 References 6 Appendix 7 Release
More informationOriginal operating instructions Fail-safe inductive sensor GG711S
Original operating instructions Fail-safe inductive sensor GG7S 8236522 / 2 / 26 Contents Preliminary note...3. Symbols used...3.2 Warning signs used...3 2 Safety instructions...4 2. Safety-related requirements
More informationXPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output
Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation
More informationPS24A. RTU32M Power Supply. Data Sheet Doc: v1.00 / December 17 th, 2018
PS24A RTU32M Power Supply Data Sheet Doc: 40407 v1.00 / December 17 th, 2018 Ctents INTRODUCTION to LB2 I/O series... 3 IO MODULE BACKPLANE PART... 3 VERSIONS / ORDERING CODES... 3 Order code: AO02A...
More informationVersaMax IP Input Module
Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm
More informationProportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32
www.atos.com Table F035-20/E Proportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32 1 MODEL CODE AGMZO Proportional pressure relief valve
More informationOperating Instructions
Key Adapter CKS-K-AS2A-U-C20-PC (Unicode) EN Contents 1. About this document... 3 1.1. Scope...3 1.2. Target group...3 1.3. Key to symbols...3 1.4. Supplementary documents...3 2. Correct use... 4 3. Description
More informationSUBCON-PLUS-PROFIB...
Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
More information