194E FA 32 E P11 P11 6

Size: px
Start display at page:

Download "194E FA 32 E P11 P11 6"

Transcription

1 Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure UL Type //, IP E-CA Stainless Steel Enclosure UL Type /, IP E-KA Non-Metallic Enclosure UL Type //, IP E-AA Metallic Enclosure UL Type, IP E-GA Painted Steel Enclosure UL Type //, IP E-DA Stainless Steel Enclosure UL Type /, IP Explanation FA GA CA DA KA AA a Enclosure Type UL Type //, IP Painted Steel, Hinged, for A switches UL Type //, IP Painted Steel, Hinged, in x x in. size, for A -pole switches UL Type /, IP Stainless Steel, Hinged, for A switches UL Type /, IP Stainless Steel, Hinged, in x x in. size, for A -pole switches UL Type //, IP Non-Metallic, for A switches UL Type, IP Painted Steel, Hinged, for A switches (Same enclosure as FA without gasketing) E FA E P P a b c d d e b Load Size A A A A A A A Blank E c Handle Color (R-HS ) Grey/Black Blank d Left Side + Right Side Modifications No ption -P N.. + N.C. Auxiliary Contacts -PL N.. + N.C.L.B. Auxiliary Contacts -P N.. + N.C. Auxiliary Contacts -PD -NP -PE -TN Blank N.. E.B. Additional Pole Grounding Pole Neutral Pole e Switch Type -pole switch - Pole switch Modifications: Up to two suffix codes may be added to an enclosed disconnect load switch. See Guidelines, page -. If only one accessory is chosen, it is mounted on the left side of the switch. To order the cat. no. E-FA/FA or E-CA/CA in the larger /A sized enclosure, add an "" after the handle color. For example, E-FAE becomes E-FAE. GA and DA type enclosures: use with -pole A switches only. Special order; allow for longer delivery time. Frequently rdered Bulletin E Enclosed Switches with Bulletin R Handle Description Rated Current (A) Dimension Reference Handle Color A Black E-CA E-CAE Stainless steel Black E-CA enclosure, A IP/Type / E-CAE A Black E-CA E-CAE A Black E-FA E-FAE Painted steel Black E-FA enclosure, A IP/Type // E-FAE A Black E-FA E-FAE Non-metallic Black E-KA enclosure, C IP/Type / E-KAE Modifications: Up to two suffix codes may be added to an enclosed disconnect load switch. See Guidelines, page -. If only one accessory is chosen, it is mounted on the left side of the switch. - Publication A-CAA-EN-P

2 Bulletin E IEC Load Switches, A verview Bulletin E IEC Load Switches Suitable as At-Motor Disconnect Switch (UL),,,,,, A Inductive Load-Rated Switches IP/ UL Type //R/ perating Handles IPL Finger-Safe Terminals - and -Pole Versions; Add-on Accessory Poles to Make -, -, - and -Pole Units Front/Door or DIN/Base Mounting Configurations Available in FF-N and Changeover Configurations - and -Pole Enclosed Switches ptional Thermoplastic Enclosures Positive-Guided Actuation Padlockable Handles Available (up to padlocks) Table of Contents Product Selection... - Accessories... - Specifications... - Approximate Dimensions... - Standards Compliance IEC - IEC - Low-voltage switchgear and control gear part UL CSA: C. No. Certifications UL Listed (File No. E, Guide NLRV) CSA Certified (LR ) IEC, VDE and BS CE RINA Italian Naval Registry CCC Description Bulletin E load switches are designed for use as local motor isolation and disconnect switch applications. Available with - and -pole versions with add-on additional poles, grounding and neutral terminals and auxiliary contacts, Bulletin Es share the same operating handles as the Bulletin L Control and Load Switches. Bulletin E switches are offered in two mounting styles, Front/Door and Base/DIN configurations for a variety of installations. Switch body styles for Bulletin E base-mounted switches include standard interlock shaft; Bulletin E front-mounted switches include standard shaft. Two-position FF-N switch is used to connect or disconnect a variety of inductive loads, including solenoids, valves, magnetic starters, relays, and motors. Handles featuring marked legend plates are available in Selector-Knob, Disk-Style, Rectangular-Style and Key-perated versions. Selector-Knob versions are available in three sizes. Most handles are available in colors of Grey/Black or and have padlockable versions. - Publication A-CAA-EN-P

3 Bulletin E IEC Load Switches, A Catalog Number Explanation/Product Selection Explanation E A Small-Frame Switches (Handles listed on page -) -Pole Base Mount -Pole Front Mount -Pole Base Mount -Pole Front Mount A E a Installation Type Description Base/DIN Mounting Front/Door Mounting E A b Load Size Description A A A A A A A a b c c Function/Circuit Diagram Ref. # Function Description Circuit Diagram Ref. # FF/N -Pole, -Position ( ) FF/N -Pole, -Position ( ) FF/N -Pole, -Position ( - inverted) Changeover -Pole, -Position ( ) Frequently rdered FF-N -Pole Switch (includes operating shaft) (Handles listed on page -) Function Switching Angle FF Function Switching Angle FF N N No. of Circuits No. of Circuits Contact Target Configuration = Contact Closed = Contact pen Handle Position Base-Mounted Front-Mounted FF/ N/ ACA Rated Power V Rated Current [A] [kw] at V AC Hz AC Hz Ø.. E-A- E-E- E-A- E-E- Contact Target Configuration = Contact Closed = Contact pen FF-N -Pole Switch (includes operating shaft) Handle Position Base-Mounted Front-Mounted FF/ N/ ACA Rated Power V Rated Current [A] [kw] at V AC Hz AC Hz Ø.. E-A- E-E- See Catalog No. Explanation for more load size and change-over switch options. FF-N -Pole Switch (includes operating shaft) E-A- E-E-. E-A- E-E- E-A- E-E- E-A- E-E- E-A- E-E- Frequently rdered FF-N -Pole Switch (includes operating shaft) (Handles listed on page -) E-A- E-E- E-A- E-E-. E-A- E-E- E-A- E-E- E-A- E-E- E-A- E-E- Publication A-CAA-EN-P -

4 Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E/L Handles (for use with Bulletin E Switches) Color Handles (Includes Legend Plate and Control Knob) (Emergency Stop colors) Type I (IP, UL Type /R/) Type L (IP, UL Type /R/) With Locking For ne Padlock (Padlock Not Included) Type N (IP, UL Type /R/) Bulletin L handles are available in both screw fixing and. mm mounting hole style. Black/Grey (Standard peration colors) Handle Type E L G N L Degree of Protection Handle Color Bezel Plate Size For Use With Black/Grey E- A x mm L-E A, - (-/ x -/ in.) L-A A, - IP (UL Type ) (UL Type /R/) IP (UL Type /R/) IP (UL Type /R/) Type A (IP, UL Type /R/) Black/Grey Type E (IP, UL Type /R/) With Locking For ne Padlock (Padlock Not Included) x mm (-/ x -/ in.) x mm (-/ x -/ in.) x mm (-/ x -/ in.) x mm (-/ x -/ in.) x mm (-/ x -/ in.) x mm (-/ x -/ in.) x mm (-/ x -/ in.) x mm (-/ x -/ in.) Type G (IP, UL Type /R/) These handles are for use with - and - (N-FF) switches only and are dual marked with N-FF and -. Explanation HC HE Use with Handle Type A, E, I, L S A, E, I, L G, N S A, I G, N a Installation Type. mm Mounting Hole Style Handle (for use with front-mounted switches) Screw-Mounting Handle (for use with front- and base-mounted switches) b Handle Legend Plate Size mm x mm (-/ in. x -/ in.) mm x mm (-/ in. x -/ in.) mm x mm (-/ in. x -/ in.) mm x mm (-/ in. x -/ in.) mm x mm (-/ in. x -/ in.) mm x mm (-/ in. x -/ in.) mm x mm (-/ in. x -/ in.) L HE N Use With E Switch Size E- A E- A E- A E- A E- A E- A E- A a b c d c Legend Plate Type Color A Square Grey/Black I Square E Square/Lockable Grey/Black L Square/Lockable G N S Disc/Lockable (up to locks) Disc/Lockable (up to locks) Large Square with extra legend area Grey/Black Grey/Black For. mm mounting hole style handle (code HC), select either handle type A, E, I, or L with x mm legend plate size (code ) only or handle type G or N with x mm legend plate size (code ) only. rder E- A Type G and N handles as E-HEN- or E-HEG- Use Type G and N with N-FF function only (selection "d", code -) R-HE front-mounting switch only Frequently rdered L Handles FF-N Base/Front-Mounted - and -Pole Switch Handles (Switch Body listed on page -) E- A L-E A, - L-A A, - E- A E- A L-E A, - L-A A, - E- A E- A E- A L-E A, - L-A A, - E- A L-E A, - Legend Plate Marking - L-HEE- FF-N L-HEE-I - L-HEL- FF-N - FF-N - FF-N - FF-N - FF-N - FF-N Type S (IP, UL Type /R/) d Description Legend Marking -I N I FF-N -- (Reversing) -- ( degrees) (Changeover) -I I FF-N FF FF N L-HEL-I E-HEG- L-HEG- L-HEG- E-HEN- L-HEN- - FF-N L-HEN- - L-HCL- FF-N L-HCL-I - Publication A-CAA-EN-P

5 Bulletin E IEC Load Switches, A Catalog Number Explanation/Product Selection Bulletin E pen and Enclosed Switch Kits Explanation A E Y a Installation Type Base/DIN Mounting, open type switch Front/Door Mounting, open type switch Enclosed Base Mounting Switch With Handle (Uses IP ABS thermoplastic enclosure) E Y N b Load Size A A A A A A A a b c d For A Enclosed Switch: use "M" (-pole enclosure has M/ knockouts, -pole A enclosure has M/ knockouts). For / A Enclosed Switch with M/ metric knockouts: use M or M. c Configuration -Pole FF/N ( ) -Pole FF/N ( ) N G A N G A d Handle Style E-HEN- (use with A Switch) E-HEG- (use with A Switch) L-HEA- (use with A Switch) L-HEN- (use with A Switch) L-HEG- (use with A Switch) L-HEA- (use with A Switch) Frequently rdered Switch Kits FF-N Front- and Base-Mounted -Pole Switch With L-HEN- Handle Function Switching Angle FF N Rated Current [A] ACA Rated Power [kw] at V AC V AC Hz, Ø Base-Mounting Distribution Switches (handles are pre-assembled to switch) Function Switching Angle FF N No. of Circuits Base-Mounted Front-Mounted. E-A--N E-E--N E-A--N E-E--N. E-A--N E-E--N Contact Target FF/ N/ Handle Color Frequently rdered Enclosures - and -Pole Enclosed Switches With L-HEN- perating Handles No. of Poles Function Switching Angle FF N Legend Plate Marking Lockable (ne Padlock) Rated Current [A] ACA Rated Power [kw] at V AC V AC Hz, Ø E-A--R - Yes Black/Grey - No E-A--Q - Yes E-A--R Black/Grey - No E-A--Q Rated Current [A] Handle Color E-Y--N E-Y--N E-Y--N E-Y--N Uses Base-Mounted Switches E-Y--N Publication A-CAA-EN-P -

6 Bulletin E IEC Load Switches, A Accessories IEC Load Switch Accessories E-E A, Front/Door Mounting () -Pole Auliliary Contact or () -Pole Auliliary Contact or Grounding Terminal or Additional Pole Neutral Terminal or () -Pole Auliliary Contact or () -Pole Auliliary Contact E-A A, Base/DIN Rail Mounting () -Pole Auliliary Contact or () -Pole Auliliary Contact or Grounding Terminal Additional Pole or Neutral Terminal or () -Pole Auliliary Contact or () -Pole Auliliary Contact Accessory Configuration Guidelines Accessory drawings represent modular, snap-on features of Bulletin E accessories. They are not suggesting possible accessory configurations. Use the following guidelines for choosing E accessory configurations. Up to two accessories may be added to the Bulletin E switch body. For the E,,,, or A switches, the early break auxiliary contact (-PD) may only be used in the following configurations: As a single unit on either side of the switch As a single unit on a side when used with a switch + th pole (-NP) As a single unit on a side when used with a switch + ground terminal (-PE) As a single unit on a side when used with a switch + neutral terminal (-TN) No other auxiliary contact may be used in combinations with an early break auxiliary contact (-PD) ther combinations of auxiliary contacts are permissable. For the E and A switches, any combination of auxiliary contacts, th pole, ground terminal, neutral terminal, and -PD is permissable. Publication A-CAA-EN-P -

7 Bulletin E IEC Load Switches, A Accessories Auxiliary Contacts No. of Auxiliary Contacts For Use With N.. + N.C. E-A E-A-P E-E E-E-P N.. + N.C.L.B. E-A E-A-PL E-E E-E-PL N.. + N.C. E-A E-A-P E-E E-E-P E-A E-A-PD N..E.B. E-A... E-A-PD E-E E-E-PD E-E... E-E-PD Additional Pole, N.. For Use With E-A E-A E-A E-A E-A E-A E-A E-E E-E E-E E-E E-E E-E E-E E-A-NP E-A-NP E-A-NP E-A-NP E-A-NP E-A-NP E-A-NP E-E-NP E-E-NP E-E-NP E-E-NP E-E-NP E-E-NP E-E-NP -Pole Mechanical Coupling For Use With E- E-G E-/ E-G E-/ E-G E-/ E-G Earthing/Grounding Terminal For Use With E-A E-A/ E-A/ E-A/ E-E E-E/ E-E/ E-E/ E-A-PE E-A-PE E-A-PE E-A-PE E-E-PE E-E-PE E-E-PE E-E-PE Neutral Terminal For Use With E-A E-A/ E-A/ E-A/ E-E E-E/ E-E/ E-E/ E-A-TN E-A-TN E-A-TN E-A-TN E-E-TN E-E-TN E-E-TN E-E-TN A maximum of two side-mount accessories may be added to a E switch (one on each side). ABS Thermoplastic Enclosure IP, For High-Impact Applications (grounding screw included) Description No. of Poles For Use With E-A/ L-G E-A/ E-G For PG cable glands E-A/ E-A/ E-G E-A/ E-A/ L-GM E-A/ E-GM For metric cable glands E-A/ E-A/ E-GM E-A/ - Publication A-CAA-EN-P

8 Bulletin E IEC Load Switches, A Accessories Noryl Thermoplastic Enclosures IP, For Corrosion-Prone Applications (grounding screw included) Description No. of Poles For Use With For PG cable glands For metric cable glands E-A/ L-G E-A/ E-A/ E-A/ E-A/ E-G E-G E-A/ L-GM E-A/ E-A/ E-A/ E-A/ E-GM E-GM Description For Use With Pkg. Qty. Additional Earth/Ground and Neutral L-G, G, G, G E-G Terminals For Thermoplastic Enclosure L-G and G E-G Terminal Covers No. of Poles For Use With E- E--C E- E--C E-/ E--C E-/ E--C E-/ E--C E-/ E--C E-/ E--C E-/ E--C User must order () Bulletin E -Pole Switches separately. Coupling for changeover switch not available. Changeover switch must be ordered as a factory-assembled device (e.g., E-A-). perating Shafts Length Construction Pkg. Qty. mm (-/ in.) Plastic L-G Standard Shaft (for front-mount switches) Metal E-G mm (-/ in.) Plastic L-G (Standard Length) Metal E-G mm (-/ in.) Plastic L-G Metal E-G Interlock Shaft (for base-mount switches) mm (-/ in.) Plastic L-G Bulletin E Load Switch Shaft Selection for use with E and L Thermoplastic Enclosures Rated Current [A] -Pole Switches (- suffix) -Pole Switches (- suffix) Changeover Switches (- suffix) E-E E-A E-E E-A E-E E-A plastic shaft ( L-G) plastic shaft ( L-G) plastic shaft ( L-G) No. E-G) No. E-G) No. E-G) No. E-G) plastic shaft ( L-G) plastic shaft ( L-G) plastic shaft ( L-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. L-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) No. E-G) Publication A-CAA-EN-P -

9 Bulletin E IEC Load Switches, A Accessories/ther Accessories Shaft Extension Kits Shaft Extension Length For Use With Pkg. Qty. mm (/ in.) Per Extension E-A L-G Metal Shaft Extensions With Padlock Provision in FF Position Length For Use With Pkg. Qty. mm (-/ -/ in.) mm (-/ -/ in.) Metal Shaft Adaptor Kits For use with R Type / Handles Metal shaft adaptor kits for use with R Type / handles kit includes bezel adapter and R-R operating shaft. perating handle ( R-HS) must be ordered separately. Metal Shaft Extension For modification of L-G/ G when used with any switches other than -position, rotation. E-A ther Accessories L/E. mm Mounting Hole Style Handles (Type B, D) (For Front-Mounted Switches) Description L-G L-G For Use With Pkg. Qty. E-A E-G E-A L-G. mm Mounting Hole Style Handles (IP) Handle Style: Knob Lever with Latch (For Use With E-E A, -) or L- E A L-HCB- Type B Type D. mm Mounting Hole Style Handles Key Removal Position (Includes Latch) For Use With L-E A, E-E A, -. mm Mounting Hole Style Handles Key Removal Position (Includes Latch) For Use With L-E A, E-E A, -. mm Mounting Hole Style Handles Key Removal Position (Includes Latch) For Use With L-E A, E-E A, - L-HCDC- L-HCDD- L-HCDG- Accessory Description Pkg. Qty. Control Knob, Black, with Locking Facility (Use / in. max. hasp lock.) (Locks in,,, L-GN and positions) Control Knob, Red, with Locking Facility (Use / in. max. hasp lock) L-GR These locking knobs can only be added to the "HE" style actuators. If a locking knob is desired on a "HC" style actuator, it has to be ordered as part of the main catalog number. For example, L-HCE-. - Publication A-CAA-EN-P

10 Bulletin E IEC Load Switches, A ther Accessories Accessory Description Pkg. Qty. Control Knob, Type P Control Knob, Black, mm (-/ in.) Diameter Control Knobs, Type P Control Knob, Red, mm (-/ in.) Diameter Control Knob, Black, L =. mm (-/ in.) Control Knob, Black, L = mm (-/ in.) Control Knob, Red, L =. mm (-/ in.) Control Knob, Red, L = mm (-/ in.) L-GN L-GR L-GN L-GN L-GR L-GR Standard Black Control Knob Rectangular Front Frame Rectangular front frame with blank nameplate L = x mm (-/ x -/ in.) Rectangular front frame with blank nameplate L = x mm (-/ x -/ in.) L-G L-G Additional Legend Plates/Frames Color Legend Size For Use With Pkg. Quantity Black/Grey Black/Grey. mm x mm / in. x -/ in. x mm / x -/ in. Size Type G and N style handles, Cat. Nos. L- HEG/N Size Type G and N style handles, Cat. Nos. L- HEG/N Legend Plate Marking (Blank) MAIN SWITCH HAUPSCHALTER INTERR. PRINCIPALE INTERR. PRINCIPAU INTERR. PRINCIPAL HUVUDBRYTARE WAHLSCHALTER EMERGENCY FF (Blank) MAIN SWITCH HAUPTSCHALTER INTERR. PRINCIPALE INTERR. PRINCIPAU INTERR. PRINCIPAL HUVUDBRYTARE WAHLSCHALTER EMERGENCY FF L-G L-GA L-GB L-GC L-GD L-GE L-GF L-GG L-GH L-G L-GA L-GB L-GC L-GD L-GE L-GF L-GG L-GH Legend Plates with Bezel Legend Plate Color Silver Yellow Pkg. Quantity Custom-Engraved legend plates available. To order, use publication L-PP_-EN-P. Legend Plate Marking - FF-N Blank Legend Plate L-A- L-A-I L-A- L-A- L-A-I L-A- L-A- L-A-I L-A- L-I- L-I-I L-I- L-I- L-I-I L-I- L-I- L-I-I L-I- Publication A-CAA-EN-P -

11 Bulletin E IEC Load Switches, A ther Accessories Shaft for Enclosures Enclosure Type Suitable For L (Base-Mounted Switches) No. of Contacts Shaft Suitable For Use with E Switch No. of Poles Shaft Required L-G L-A() / L-G E-A() and L-G L-G L-A() / Standard L-A() / L-G ( x x mm) L-A() / Standard L-G L-A() / L-G L-G L-A() / L-G L-A() / Standard L-A() / L-G ( x x mm) L-A() / Standard E-G E-A() and L-G E-G E-A() Standard ( x x mm) E-G E-A() and E-G E-G E-A() Standard ( x x mm) Accessory Combinations in Enclosure Enclosure Type Switch No. of Poles Shaft L-G (ABS) L-G (Noryl) E-A() L-G Aux. Contacts (single or double) Additional Pole Block Neutral Terminal Block n Switch Ground Terminal Block Neutral Terminal Block n Enclosure ( x x mm) E-G (ABS) E-A() L-G E-G (Noryl) ( x x mm) E-A() E-G E-G (ABS) E-A() E-G E-G (Noryl) ( x x mm) E-A() E-G L+R Ground Terminal Block - Publication A-CAA-EN-P

12 Bulletin E IEC Load Switches, A Specifications Electrical Ratings Performance Data A A A A A A A Aux. IEC Applications Contacts Rated operational voltage (U e ): IEC [V] Rated operational voltage ( U e ): UL, CSA [V] Rated isolation voltage ( U i ): IEC/UL, CSA [V] / / / / / / / / Rated impulse voltage ( U imp ): UL, CSA [kv] Test voltage, ( U i ) minute [kv] Lost power per pole [W] Rated frequency [Hz] / / / / / / / / Conventional free air thermal current I th [A] Conventional enclosed thermal current I e [A] Rated current I e AC-/ Non-inductive or only slightly inductive loads [A] AC-A Switching of resistive loads with slight overload Rated power P e AC-A ccasional switching of Ø motors V [kw].... and other highly inductive loads V [kw]. (criterion for selecting main switches) V [kw].. V [kw]... AC- Squirrel-cage motors; starting and stopping of running motors V [kw]... V [kw]... Short circuit current (co-ordination type ) [ka] Rated conditional short-circuit current Maximum fuse rating of circuit (type g,g) /V [A] Rated short-time current I cw ( s) [A] V [A] Rated breaking capacity ACA (cosφ.) V [A] V [A] DC switching capacity /V [A] Rated current I e pole V [A] V [A]. V [A] V [A] poles V [A] in V [A] DC-A For resistive loads, series V [A].. T ms V [A]..... U e max = V V [A] poles V [A] in series V [A] V [A]... Rated power P e DC-A, DC-, DC- V [kw] For inductive loads, T ms See standards compliance listed on page -. Suitable also for SEV. poles in series V [kw]..... V [kw] V [kw] V [kw] Publication A-CAA-EN-P -

13 Bulletin E IEC Load Switches, A Specifications Electrical Ratings, Continued Performance Data A A A A A A A Aux. UL/CSA Applications Contacts Continuous current [A] Heavy Pilot Duty [AC] A A A A Standard Duty [DC] Q Motor rating Hz FLA V, P Hp. FLA V, P Hp Single-phase ( FLA.. poles) V, P Hp. V, P FLA... Hp. V, P FLA.... Hp. Three-phase V, P FLA.. Hp. V, P FLA Hp. V, P FLA Hp Mechanical Data Performance Data A A A A Aux. Contacts Protection class according to IEC Motor rating Hz handles IP IP IP IP IP switch bodies IP IP IP IP IP Mechanical life [million operations]..... Max wire gauges Terminal size per IEC - A A A A xa rigid wire fine strands / conductor / conductor AWG mm AWG mm () /() () /() () /() (). /(). () /() (). /(). () /() (). /() () /() (). /(). () /() (). /(). () /() () /() () /() () /().... Environmental Data Storage peration + C ( + F) + C ( + F) - Publication A-CAA-EN-P

14 Bulletin E IEC Load Switches, A Appropriate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Front Installation E-E (/) (/). (/) Dia.. (/) -Pole -Pole Handles P Q L-HEA L-HEI L-HES E-HEN E-HEG L-HEA L-HEI L-HES L-HEN L-HEG (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) x (-/ x -/) x (-/ x -/) x (-/ x -/) x (-/ x -/) x (-/ x -/) x (-/ x -/) x (-/ x -/) x (-/ x -/) x (-/ x -/) x (-/ x -/) Switch Body Use with B B F H L G E-E E-E/ E-E/ E-E/ (-/) (-/) (-/) (-/) N/A N/A (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) () (-/) (-/) (-/) Does not apply to E-/A, -Pole Switches. Use B dimensions for -pole devices. For -pole switches, add in. to the "L" dimension. (-/) (-/) (-/) (-/) E-E Switch Body with L-HCA Handle for. mm Hole Mounting Style Type L E-E () E-E/. (-/) E-E/. (-/) E-E/. (-/) Publication A-CAA-EN-P -

15 Bulletin E IEC Load Switches, A Appropriate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Base Mounting E-A -Pole -Pole Handles P Q L-HEA (-/) L-HEI (-/) L-HES (-/) E-HEN (-/) E-HEG (-/) L-HEA (-/) L-HEI (-/) L-HES (-/) L-HEN (-/) L-HEG (-/) x (-/ x -/) x (-/ x -/) x (-/ x -/) x (-/ x - /) x (-/ x - /) x (-/ x -/) x (-/ x -/) x (-/ x -/) x (-/ x -/) x (-/ x -/) Cover Requirements For Use With Y min. Y max. E-A (/) (-/). (/) (-/) E-A/ (/) (-/). (/) (-/) E-A/. (/) (-/). (/) (-/) E-A/. (/) (-/). (/) (-/) Switch Body Use With D E F F G H L J E-A. (/) E-A/. (/) E-A/. (/) (- /) (- /) (- /) E-A/. (/) (-/) (- /) (- /) (- /). (- /) For -pole switches, add in. to the "L" dimension.. (/) (- /) (/) (-/) (/). (/) (- /) (- /) (- /) (- /) (- /) (- /) (- /) (- /) (- /) (-/) (- /) (- /) (-/) (- /) - Publication A-CAA-EN-P

16 Bulletin E IEC Load Switches, A Appropriate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Base Mounting E-A E-A Switch Body with L-G Shaft Extension Shaft extensions Switch body L With shaft extension (-/) With shaft extensions (-/) With shaft extensions () With shaft extensions (-/) With shaft extensions (-/) With shaft extensions (-/) For -pole switches, add in. to the "L" dimension. Switch Body E-A E-A / E-A / E-A / (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) Shaft L-G L-G L-G Y.. (/ /) (/ /) (/) (/) Handles Type B Q P L-HEA L-HEI E-HEG E-HEN L-HEA L-HEI L-HEN L-HEG (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) x (-/ x -/) x (-/ x -/) x (-/ x -/) x (-/ x -/) x (-/ x -/) x (-/ x -/) x (-/ x -/) x (-/ x -/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) (-/) Publication A-CAA-EN-P -

17 Bulletin E IEC Load Switches, A Appropriate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Base Installation E-A E-A Switch Body with Metal Shaft Extension L-G L-G A (-/ -/) (-/ -/) E-A E-A/ E-A/ E-A/ L () (-/) (-/) (-/) Base and Front Installation For -pole switches, add in. to the "L" dimension. E with Auxiliary Contact Block Installed E with -Pole, Ground and Neutral Terminals Contacts N.. + N.C. N.. + N.C. M (/) (/) E- E-/ E-/ E-/ M. (/) (/). (/) (/) - Publication A-CAA-EN-P

18 Bulletin E IEC Load Switches, A Appropriate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Base Mounting E-A Thermoplastic Enclosures Complete Switches E-Y E-Y/ E-Y/ Poles Enclosures ABS Noryl and E-G E-G and L-G L-G E-G E-G and E-G E-G E-G E-G E-Y/ and E-G E-G Height A (-/) (-/) (-/) (-/) (-/) (-/) (-/) Width B (-/) (-/) (-/) (-/) (-/) (-/) (-/) M/M / mm M/M / mm Knockouts ØD PG/PG./. mm PG/PG./. mm PG/PG./. mm PG/PG./. mm PG/PG./. mm PG/PG./. mm PG/PG./. mm Mounting Holes E (-/) n Center (-/) n Center n Center (-/) (-/) F (-/) (-/) (-/) (-/) (-/) (-/) (-/) Empty enclosures not available for purchase. E-A units have knockout on each end. all others have knockouts on each end. A letter "M" in the catalog number indicates metric knockouts; the unit is otherwise supplied with PG knockouts. All mounting holes have a. mm (/ in. ) diameter. E-A / E-A / E-A / No. of Extensions With extension (-/) (-/) (-/) With extensions (-/) (-/) (-/) With extensions (-/) (-/) (-/) With extensions (-/) (-/) (-/) With extensions (-/) () (-/) With extensions (-/) (-/) (-/) When more than modules are used, attach the first one to the switch body using the screws supplied with the extension ( L-G). Depth H (-/) (-/) (-/) (-/) (-/) (-/) (-/) Publication A-CAA-EN-P -

19 Bulletin E IEC Load Switches, A Appropriate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. E Enclosed Switches with R Handles () / (.) dia. mtg. holes () / (.) dia. mtg. holes Cat. Nos. E-CA, E-FA, E-AA E-KA / (.) -/ (.) -/ (.) -/ (.) (.) () / (.) dia. mtg. holes Cat. Nos. E-CA, E-FA, E-AA Cat. Nos. E-CA, E-FA, E-AA () / (.) Dia. Mtg. Holes / (.) -/ (.) E-KA () - (.) Dia. Mtg. Holes () -/ () -/ () () -/ () E-DA, E-GA - Publication A-CAA-EN-P

194E FA 32 E P11 P11 6

194E FA 32 E P11 P11 6 Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure

More information

194E FA 32 E P11 P11 6

194E FA 32 E P11 P11 6 Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable f padlocks) E-FA Painted Steel Enclosure

More information

Flexible Solutions in Contr ol and Load Switches. Bulletins 194C, 194E, 194L

Flexible Solutions in Contr ol and Load Switches. Bulletins 194C, 194E, 194L Flexible Solutions in Contr ol and Load Switches Bulletins 9C, 9E, 9L EPAND THE RANGE F YUR CNTRL Bulletin 9C Bulletin 9E Bulletin 9L Control Switch Available in ampere rating Load Switch Available in

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Rockwell utomation Inc. 0 South nd Street Milwaukee, WI 50 U.S.. U Declaration of Conformity IC Switch-Disconnectors, 00 and ccessories Name and address of

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Rockwell utomation G Industriestrasse 0 CH-5000 arau Switzerland U Declaration of Conformity IC Switch-Disconnectors, 00 and ccessories Name and address of

More information

Complete UL/CSA Disconnect Switch Kits

Complete UL/CSA Disconnect Switch Kits Product Selection Complete UL/CSA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA handle, auxiliary contacts, and padlock attachment.

More information

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Bulletin 194R Fused and Non-Fused Disconnects Product Selection Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 10V 40V 40V 480V V 1V 0V Ref. Cat. No. Non-d 0 7. 1 0 A 194R-0-NN 60 1 0 40 B 194R-60-NN UL Class

More information

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Bulletin 194R Fused and Non-Fused Disconnects Product Selection Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 1V 240V 240V 480V V 12V V Ref. Non-d 0 2 7. 1 A2 194R-0-NN 60 1 0 40 B2 194R-60-NN UL Class CC

More information

Disconnect Switches. Safe Switching and Disconnecting

Disconnect Switches. Safe Switching and Disconnecting IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches. comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power

More information

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Control and Load Switches

Control and Load Switches Complete Switches Pages -...-8 Main Switches / EMERGENCY OFF Switches Series Q 9E Series B Load Switch, Type Q for Installation in istribution Cubicle 9E Series B Load Switch / EMERGENCY OFF, Type R for

More information

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

K1D004ACH cam switch - 4-pole A - for Ø 22 mm Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

K1D012ULH cam changeover switch - 2-pole A - screw mounting

K1D012ULH cam changeover switch - 2-pole A - screw mounting Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm Product data sheet Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal

More information

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal

More information

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors

More information

ALLEN BRADLEY RELAY Bulletin 700-HF

ALLEN BRADLEY RELAY Bulletin 700-HF ALLEN BRADLEY RELAY Bulletin 700-HF Contact Rating DPDT, 3PDT, 4PDT Plug-in Quick Connect Solder Terminals Options: LED, Push-to-Test Operator DEMENSIONS: Bulletin 700-HF Relay (DPDT) Bulletin 700-HF (3PDT)

More information

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-...

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-... Circuit Breakers, 09/054 Moeller Electric Corporation Auxiliary Contacts for Type Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic N.O. N.C. Standard auxiliary

More information

Motor protection relays

Motor protection relays Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30

More information

TeSys contactors From 115 to 2750 A

TeSys contactors From 115 to 2750 A Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

K1B004TLH cam switch - 1 pole A - screw mounting

K1B004TLH cam switch - 1 pole A - screw mounting Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam

More information

Motor protection circuit breakers

Motor protection circuit breakers Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability

More information

Bulletin 817 Thermistor Protection Relay

Bulletin 817 Thermistor Protection Relay 6 Bulletin 817 Accurate Temperature Monitoring for Critical Applications Automatic, Manual and Remote Reset Status Indicating LEDs DIN Rail or Panel Mounting Guarded Terminals IP20 1 N.O. and 1 N.C. Output

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)9-...

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)9-... Circuit Breakers, 09/074 Moeller Electric Corporation Auxiliary Contacts for Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic device N.O. N.C. Standard auxiliary

More information

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B)-...

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B)-... Circuit Breakers, Disconnect Switches, Molded Case Switches 09/064 Moeller Electric Corporation Auxiliary Contacts for. Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering

More information

Push Buttons and Operator Interface New Product Catalog XAL Control Stations

Push Buttons and Operator Interface New Product Catalog XAL Control Stations Push Buttons and Operator Interface New Product Catalog XAL Control Stations CONTENTS Description.................................................... Page General Information................................................104

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green 22.5 mm 3.5 mm IP65 1 A 66 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales office. INDICATOR

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

K1F006ALH cam switch - 6-pole A - screw mounting

K1F006ALH cam switch - 6-pole A - screw mounting Characteristics cam switch - 6-pole - 45-12 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting

More information

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches

More information

Allen-Bradley 1492-RCDA4A40

Allen-Bradley 1492-RCDA4A40 Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps

More information

XCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13 Characteristics limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 80.00 USD Main Range

More information

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)

More information

Switch rated plugs and receptacles with NEMA 4X protection

Switch rated plugs and receptacles with NEMA 4X protection DSN Features and Ratings p. 22 DSN20 p. 23 DSN30 p. 25 DSN60 p. 27 Spare parts p. 29 Dimensions p. 31 21 Switch rated plugs and receptacles with NEMA 4X protection DSN Series products are switch and hp

More information

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices Siemens AG 201 SENTRON 3LD Main Control and EMERGENCY-STOP Switches Catalog Extract LV 10 Edition 10/201 siemens.com/switching-devices Siemens AG 201 Related catalogs Low-Voltage Power Distribution and

More information

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers Type CTI 25M, CTI 45MB Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is

More information

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1 Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload

More information

M C. Ex d M-0... control, monitoring and signalling devices

M C. Ex d M-0... control, monitoring and signalling devices Ex d M-0... control, monitoring and signalling devices M-0 M-0 series control, monitoring and signalling devices are installed as external accessories on Cortem 'Ex d' enclosures used in any industrial

More information

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20 Characteristics limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20 Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device

More information

Limit switches 3. with solenoid interlocking. Metal, type XCSE and XCSL. Page 6/284. Page 6/296

Limit switches 3. with solenoid interlocking. Metal, type XCSE and XCSL. Page 6/284. Page 6/296 ntroduction, Specifi cations Limit switches with solenoid interlocking etal, type CSE and CSL Plastic, double insulated, type CSTE etal, type CSE and CSL Safety interlock switches with locking of the actuator

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

2-Position Cylinder Lock Operator Cat. No. 800T-H33A 800 T H31 A. Protection Rating Description T Metal, Type 4/13

2-Position Cylinder Lock Operator Cat. No. 800T-H33A 800 T H31 A. Protection Rating Description T Metal, Type 4/13 2-Position Selector Switch Devices, Non-Illuminated (Bul. 800T only) 2-Position Cylinder Lock Operator Cat. No. 800T-H33A 800 T H31 A a b c d e a Protection Rating T Metal, Type 4/13 Blank C H31 H32 H33

More information

For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T

For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T Presentation XCR With head for rotary movement operators, spring return to off position (1 contact

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

General Informations 2 Technical data 3 Basic designs 4-8

General Informations 2 Technical data 3 Basic designs 4-8 Contents Page General Informations 2 Technical data 3 Basic designs 4-8 Cam Switches On-Off switches, Changeover switches 9-12 Star-Delta switches 13-15 Multi speed switches 16-20 Control switches 21-23

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options

More information

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm Characteristics body for BCD encoded output switch - 1 pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Sub-assembly

More information

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay Bulletin -P Heavy-Duty Industrial s Product Selection DC-Operated s Rail Mount DIN Rail Mount Cat. No. Cat. No. -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD DC Coil

More information

ZB5FG09 flush mounted selector switch head key pos stay put

ZB5FG09 flush mounted selector switch head key pos stay put Characteristics flush mounted selector switch head key 455 3 pos stay put Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device short name XCKJ Sensor

More information

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland Characteristics limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland Complementary Switch actuation Electrical connection Contacts insulation form Number of steps 1 Positive opening

More information

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit

More information

Bulletin 700-HL 2-Pole Terminal Block Relay

Bulletin 700-HL 2-Pole Terminal Block Relay Bulletin 700-HL 2-Pole Terminal Block Relay Bulletin 700-HL 2-Pole "Terminal Block Relay" Relay and socket assembled interface modules for high density interposing or isolation applications Screw terminal

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

Safety switches for hinged doors

Safety switches for hinged doors C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

OsiSwitch Limit Switches Innovation through modularity

OsiSwitch Limit Switches Innovation through modularity OsiSwitch Limit Switches Innovation through modularity Osiswitch limit switches Simply Smart: Variable composition Note: All outline dimensions are in mm/inches Positive openings with rigid operators and

More information

22mm Non Illuminated Metal Operators

22mm Non Illuminated Metal Operators 22mm 22mm Non Illuminated Metal Operators Altech Corp. can provide other push button and actuator options. If your requirement calls for a 22 mm operator which is not shown, please do not hesitate to call.

More information

XCKM102 limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11

XCKM102 limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11 Characteristics limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11 Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device short

More information

Max. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2

Max. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2 Bulletin T Product Selection Thermal Overload Relays For Use With C C Setting Range [A] gl/gg Max. Backup fuse [A] UL Class K ka, V AC ka, V AC IEC/EN Coordination Type Type UL.. TAA.. TAA.. TAA.. TAA..

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS FR FX FK FW 5 6 7 11 1 14 NC NC snap action snap

More information

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R) KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ Catalog Number ➍➏➑➒ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG

More information

Cat. No. (Spring Clamp. Input Voltage

Cat. No. (Spring Clamp. Input Voltage Bulletin -HL Product Overview/Product Selection Product Selection Bulletin -HL "Terminal Block Relay" Relay and socket assembled interface modules for high density interposing or isolation applications

More information

Allen-Bradley 700-K40E-DJ

Allen-Bradley 700-K40E-DJ Bulletin Overview/Product Selection Bulletin Miniature Control Relays IEC compact industrial relay IPX Finger Protection Bifurcated contacts for low-level signals Optional integrated coil protection diode

More information

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1 KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG 551 Q4 ~

More information

Magnetically Actuated Safety Interlock Switches

Magnetically Actuated Safety Interlock Switches Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,

More information

Safety switches with separate actuator

Safety switches with separate actuator A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

SWITCH DISCONNECTORS 11

SWITCH DISCONNECTORS 11 SWITCH DISCONNECTORS 16A to 1600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 850A 1000VDC in DC21B duty

More information

3RV1 Circuit-Breakers

3RV1 Circuit-Breakers SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:

More information

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct

More information

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm Characteristics body for BCD encoded output switch - 1 pole - 30-12 A - for Ø 22 mm Complementary Main Number of decimal 11 Switching angle 30 Range of product Product or component type Component name

More information

MOTOR & CIRCUIT PROTECTION

MOTOR & CIRCUIT PROTECTION 2 MOTOR & CIRCUIT PROTECTION Motor Protection Circuit Breakers p2-1 Motor Protection Relays p2-13 Thermistor Protection Relay p2-18 Fuse Holders p2-20 Miniature Circuit Breakers p2-23 Residual Current

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

SIRIUS 3SE5, 3SE2 Mechanical Safety Switches Mechanical Safety

SIRIUS 3SE5, 3SE2 Mechanical Safety Switches Mechanical Safety SIRIUS 3SE5, 3SE2 Mechanical Safety Switches Mechanical Safety With Separate Actuator 3SE5 Interlock Switches Overview SIRIUS 3SE5, 3SE2 Mechanical Safety Switches Position switches with separate actuator

More information

Safety switches with manual mechanical delay and separate actuator

Safety switches with manual mechanical delay and separate actuator D Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF VF KEYF VF KEYF7 VF KEYF ACTUATORS MECHANICAL DELAY C L L0 Short knob 0 sec. Short knob sec.

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...

More information

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A Fuse protection The solution for > Motor load break. > Protection of industrial cabinet. > Electrical distribution. ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches

More information

30 A / 50 A / 90 A / 150 A / 250 A

30 A / 50 A / 90 A / 150 A / 250 A DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A SAFE AND SIMPLE CONNECTION, EVEN AT 250 A SAFETY SHUTTER GRP OR METAL CASING The DS family of decontactors offer ratings from 30 to 250 A (ratings

More information

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R 13.06.2016 05:27:33h Datasheet AZM 161SK 12/12RI 024 B6R Solenoid interlock / AZM 161I / AZM 161I B6R right hand model Compact design Interlock with protection against incorrect locking. For very smal

More information

CS8 Industrial Control Relays

CS8 Industrial Control Relays CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum

More information

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A

More information

Time Delay Values (E-Series)

Time Delay Values (E-Series) Time Delay Values (ESeries) AC Instantaneous 00 0 INSTANTANEOUS CURVE NO. 20 00 0 DC D.C. INSTANTANEOUS CURVE NO. 0 0. 0..0.0.00 200 300 400 500 700 800 900 0 200.00 200 300 400 500 700 800 900 0 200 Short

More information

SERIES AZ15/16. Tamper-Resistant Movable Machine Guard Safety Interlock Switch. Features & Benefits. Description. Operation. Typical Applications

SERIES AZ15/16. Tamper-Resistant Movable Machine Guard Safety Interlock Switch. Features & Benefits. Description. Operation. Typical Applications SERIES AZ15/ Tamper-Resistant Movable Machine Guard Safety Interlock Switch The Series AZ15/ is designed for use with movable machine guards/access gates which must be closed for operator safety. Their

More information

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT Characteristics limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT Complementary Switch actuation Electrical connection Contacts insulation form Number of steps 1 Positive

More information

140M C 2 E A63 KN CC GJ

140M C 2 E A63 KN CC GJ Motor Protection Circuit Breakers Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection;

More information

DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A

DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A SAFE AND SIMPLE CONNECTION, EVEN AT 250 A SAFETY SHUTTER GRP OR METAL CASING The DS family of decontactors offer ratings from 30 to 250 A (ratings

More information