Quadri-channel receiver RD10 (v.1.01_101215)

Size: px
Start display at page:

Download "Quadri-channel receiver RD10 (v.1.01_101215)"

Transcription

1 (v.1.01_101215) User manual TRIKDIS, JSC Draugystes St. 17, LT Kaunas, Lithuania Phone: Fax: : info@trikdis.lt Web:

2 Table of Contents 1 Introduction Features Technical Specifications In the box Compatible receiving modules Elements of the Receiver Preparing the Receiver for Operation Receiver Configuration... 5 Table 1. Light indication... 4 Table 2. Screen navigation buttons... 4 Table 3. Back panel elements... 4 Table 4. Recommended settings of Receiving modules... 6 Table 5. Meanings of alarm messages about Internal events

3 1 Introduction is designed to collect information from pre-installed receiving modules and redirect this information to monitoring software. Up to four different receiving modules can be inserted into mounting slots of the Receiver RD10. 2 Features - Up to 4 different receiving modules can be inserted to receive security panel messages sent in VHF/UHF frequency, GPRS, CSD, SMS connection or through telephone landlines - Displays received information on digital screen - Automatically controls connection with both pre-installed receiving modules and monitoring software - Redirects received information through serial port RS232 - Multi-protocol data output - Data buffer for temporarily storing output data - Internal clock - Can receive data from other receivers through two RS232 serial ports - Filter for repeating identical received messages 3 Technical Specifications Power supply ~ V (50 / 60 Hz) Used power 25 W Slots for receiving modules 4 RS232 data output ports 1 x DB9 Data flow rate adjustable Data output protocol Protocol is equal of exact receiving module's output protocol (tunneling) (up to 70 symbols). Time stamp can be additionally added Data buffer up to 800 messages Digital screen 4 rows of 20 characters Operating temperature from 0 C to +55 C Dimensions 19 2U (450 x 100 x 320 mm) Mass 4,2 kg 4 In the box - Quadri-channel Receiver RD10-1,5 m power supply cable - 1,8 m COM cable - User Manual 5 Compatible receiving modules - RF7 receiving module intended to receive security panel messages sent by radio VHF MHz frequency. - RF7U receiving module intended to receive security panel messages sent by radio UHF MHz frequency. - RG5 receiving module intended to receive security panel messages sent by SMS messages or through CSD connection. - RS232 receiving module intended to receive messages sent by another receiver through RS232 serial port. - RT2 receiving module intended to receive security panel messages sent through telephone landlines. 3

4 6 Elements of the Receiver 6.1 Frontal view Figure 1. View of front panel Table 1. Indicator System Output Power 1-4 Table 2. Button [Enter] [Esc] [ ] [ ] Light indication Operation LED is green when receiver is operating properly. LED is red when general error is indicated. LED is green when connection to monitoring software is through RS232 port. With no connection, LED is red. LED is green when power supply is switched on. LED Active is green when a receiving module is inserted. It is red if slot is empty. LED Status is green when receiver s concentrator is communicating with preinstalled receiving module. With no connection, LED is red. LED Event is blue when a message is being received through the port. Screen navigation buttons Function 1. Call menu. 2. Apply the function is chosen. 1. Escape menu without function applying. 2. Shift cursor right Shift up Shift down 6.2 Backward view Figure 2. View of back panel Table 3. Back panel elements Name of the element Function Output RS232 serial port to redirect information to computer with monitoring software (Mail receptacle DB9) Reset Micro-switch, which, by pressing it more than 5 seconds, restores default parameters 12V DC Backup battery connection Earth connection VAC Power supply receptacle and O/I switch coverable slots for receiving modules to be inserted 4

5 7 Preparing the Receiver for Operation 7.1 Lay the Receiver on clean horizontal surface. Screw out the fastening screws, take the lids off and insert the receiving modules. Receiving modules should be configured. (Fig. 2). 7.2 Mount the Receiver in 19 server cabinet. 7.3 Screw on the necessary antennas. 7.4 Turn the power supply switch O/I on position O. Connect the Receiver into power supply main by the power supply cable (Fig. 2). 7.5 Switch on the receiver s power supply. Turn the power supply switch on position I (Fig. 2). Receiver is powered when LED named Power is green (Fig. 1). After a sound signal the Receiver is ready for configuration. 7.6 Connect Output port of the Receiver RD10 to a monitoring software computer by the COM cable (DB9/DB9). 7.7 Set data communication parameters in order to interconnect the Receiver RD10 with monitoring software. 7.8 Set the Receiver clock. 7.9 Set the Receiver sounds. 8 Receiver Configuration 8.1 Setting of date and time (DATA/TIME). 1) Press the button ENTER. Pressing navigation buttons [ ] and [ ], stop cursor on function [DATA/TIME]. Press button ENTER for entering in submenu. 2) Set date and time pressing navigation buttons [Esc], [ ] and [ ]. Press the button ENTER for applying settings. 3) Press button ESC if you need to return to the previous menu. 8.2 Setting of Receiver options (OPTIONS). 1) Press the button ENTER. Pressing navigation buttons [ ] and [ ] stop cursor on function [OPTIONS]. Press button ENTER for entering in submenu. 2) Select [Sound] and press the [Enter]. Set one of these functions Sound off / Sound on alarm / Sound on by pressing navigation buttons [ ] and [ ]. Press the button ENTER for applying settings. 3) Select [LCD brightness] and press the button ENTER. Adjust the LCD light intensity as (LCD light high / LCD light normal) by pressing navigation buttons [ ] and [ ]. Press the button ENTER for applying settings. 8.3 Input port settings (INPUT 1...4) for interconnecting pre-installed receiving module and Receiver. 1) Press the button ENTER. Pressing navigation buttons [ ] and [ ] stop cursor on function [INPUT1... INPUT4]. Press button ENTER for entering in submenu. 2) Select [Report format] and press the button ENTER. Set one of these functions or input protocols Line off / RF7 / Other by pressing navigation buttons [ ] and [ ]. Press the button ENTER for applying settings. Settings of communication between various receiving modules and Receiver are shown in Sheet 4. 3) Select [Baud rate] and press the button ENTER. Set Baud rate 9600 b/s by pressing navigation buttons [ ] and [ ]. Press the button ENTER for applying settings. 8.4 Output settings (OUTPUT) to redirect received information to monitoring software. 1) Press the button ENTER. Pressing navigation buttons [ ] and [ ] stop cursor on function [OUTPUT]. Press button ENTER for entering in submenu. 2) Select [Report format] and press the button ENTER. Set one of these data output protocol Input or Input+Time by pressing navigation buttons [ ] and [ ]. Press the button ENTER for applying settings. 5

6 3) Select [Baud rate] and press the button ENTER. Set Baud rate 9600 b/s by pressing navigation buttons [ ] and [ ]. Press the button ENTER for applying settings. 8.5 Settings of alarm report while internal event has been occurred (ALARM REPORT). 1) Press the button ENTER. Pressing navigation buttons [ ] and [ ] stop cursor on the function [ALARM REPORT]. Press button ENTER for entering in submenu. 2) Select [Report format] and press the button ENTER. Set one of these functions or input protocols No Alarm / RF7 / Other by pressing navigation buttons [ ] and [ ]. Press the button ENTER for applying settings. 3) Select [Report code] and press the button ENTER. Select text of alarm report by pressing navigation buttons ESC, [ ] and [ ]. Press the button ENTER for applying settings. Tracing on display will appear as below: ABCDE30000## Here: 5 Number of output protocol Surgard MLR2-DG, 01 Receiver number (can be changed), 1 Line number (can be changed), 18 The sign to recognize that information goes by the protocol Contact ID, ABCD Object ID number in hexadecimal format (can be changed), E Event Qualifier, 300 Event code, 00 Partition number, 0## - Event location number. In real life digits will be here instead of symbols ## (see Table 5). Table 4. Recommended settings of Receiving modules Receiving module Output protocol Baud rate COM settings RT2 Other 9600 b/s 8-N-1-N-N RF7 RF b/s 8-N-1-N-N RS2 Other 9600 b/s 8-N-1-N-N RG3 Other 9600 b/s 8-N-1-N-N RG5 Other 9600 b/s 8-N-1-N-N RE2 Other 9600 b/s 8-N-1-N-N Table 5. Meanings of alarm messages about Internal events Message code Meaning ABCD E Trouble: any heartbeat signal through 1 st input (line) ABCD E Trouble: any heartbeat signal through 2 nd input (line) ABCD E Trouble: any heartbeat signal through 3 rd input (line) ABCD E Trouble: any heartbeat signal through 4 th input (line) ABCD E Trouble: any heartbeat signal out of monitoring software (trough output) ABCD E Trouble: Direct voltage input is less than 11,5 V ABCD E Trouble: AC V input is disabled (no power supply) 6

GSM communicator G09 (v.1.61) User Manual and Installation Guide. Draugystes g. 17, LT Kaunas

GSM communicator G09 (v.1.61) User Manual and Installation Guide. Draugystes g. 17, LT Kaunas GSM communicator G09 (v.1.61) User Manual and Installation Guide Draugystes g. 17, LT-51229 Kaunas E-mail: info@trikdis.lt www.trikdis.lt Purpose of the document This document introduces the features of

More information

GSM communicator G17F INSTALLATION MANUAL

GSM communicator G17F INSTALLATION MANUAL INSTALLATION MANUAL UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt Contents SAFETY REQUIREMENTS...3 DESCRIPTION...4 SPECIFICATIONS...4 COMMUNICATOR

More information

Control Panel CP600-eCo CP604, CP604-B

Control Panel CP600-eCo CP604, CP604-B DATA SHEET Control Panel CP600-eCo CP604, CP604-B 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP504100R0001 CP604, control panel, TFT graphical display, single-touch screen, 4.3, Active

More information

GSM communicator G16 USER MANUAL

GSM communicator G16 USER MANUAL USER MANUAL UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt Contents SAFETY REQUIREMENTS... 2 DESCRIPTION... 3 LIST OF COMPATIBLE CONTROL PANELS...

More information

Control Panel CP600 CP651, CP651-WEB

Control Panel CP600 CP651, CP651-WEB DATA SHEET Control Panel CP600 CP651, CP651-WEB 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP551100R0001 CP651, control panel, TFT graphical display, single-touch screen, 10.4, Active

More information

GSM module G10T (v.2.3x) Installation manual. TRIKDIS, JSC Draugystės st. 17, LT Kaunas Lithuania

GSM module G10T (v.2.3x) Installation manual. TRIKDIS, JSC Draugystės st. 17, LT Kaunas Lithuania GSM module G10T (v.2.3x) Installation manual TRIKDIS, JSC Draugystės st. 17, LT-51229 Kaunas Lithuania E-mail: info@trikdis.lt www.trikdis.lt Table of Contents GSM module G10T... 3 Operating... 3 Outside

More information

Control Panel CP600 CP635-FB, CP635-FW

Control Panel CP600 CP635-FB, CP635-FW DATA SHEET Control Panel CP600 CP635-FB, CP635-FW 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP535110R6001 CP635-FB, control panel, TFT graphical display, single-touch projected Active

More information

CMi- box. M-Bus Metering Gateway for Mobile Network GSM/GPRS TCP/IP. CMi-Box

CMi- box. M-Bus Metering Gateway for Mobile Network GSM/GPRS TCP/IP. CMi-Box CMi Series CMi-Box CMi- box M-Bus Metering Gateway for Mobile Network The CMi-Box is a flexible solution for collection of meter values which can be customized to meet each individual customer s needs.

More information

Control Panel CP600 CP635, CP635-B, CP635-WEB

Control Panel CP600 CP635, CP635-B, CP635-WEB DATA SHEET Control Panel CP600 CP635, CP635-B, CP635-WEB 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP535100R0001 CP635, control panel, TFT graphical display, single-touch screen,

More information

User Guide Automatic Transfer Switch (ATS)

User Guide Automatic Transfer Switch (ATS) User Guide Automatic Transfer Switch (ATS) V.1.0 Table of Contents 1. Introduction... 2 2. Product Overview... 2 3. Important Safety Warnings... 3 4. Operation Indicators & Status... 3 5. Installation...

More information

UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA Webpage: GSM communicator G16T USER MANUAL

UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA   Webpage:  GSM communicator G16T USER MANUAL UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt GSM communicator G16T USER MANUAL Contents SAFETY REQUIREMENTS... 2 1 DESCRIPTION... 3 SPECIFICATIONS...

More information

UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA Webpage: io expander Installation manual

UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA   Webpage:   io expander Installation manual UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt Installation manual Contents SAFETY REQUIREMENTS... 2 1. DESCRIPTION... 3 1.1. TECHNICAL PARAMETERS...

More information

GSM module G10 (v.1.3x) User manual. JSC UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA Webpage:

GSM module G10 (v.1.3x) User manual. JSC UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA   Webpage: GSM module G10 (v.1.3x) User manual JSC UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt Contents GSM module G10... 3 Operation... 3 Outside view...

More information

GSM module G10. User manual. (v.1.xx) JSC UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA Webpage:

GSM module G10. User manual. (v.1.xx) JSC UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA   Webpage: GSM module G10 (v.1.xx) User manual JSC UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt Contents GSM module G10... 3 Operation... 3 Outside view...

More information

RC1170-RC232 USER MANUAL

RC1170-RC232 USER MANUAL RC1170-RC232 USER MANUAL Overview: Introducing RC11XX-RC232 RF Transceiver boards for the data transmission using RF. Where RC11xx transceiver modules are compact surface-mounted high performance modules

More information

UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA Webpage: GSM communicator G10. (v.1.

UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA   Webpage:   GSM communicator G10. (v.1. UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt GSM communicator G10 (v.1.xx) USER MANUAL Description The communicator G10 is designed to transmit

More information

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

GSM-X. Communication module. Quick installation guide. Full manual is available on   Firmware version 1.02 gsm-x_sii_en 08/18 GSM-X Communication module Quick installation guide Full manual is available on www.satel.eu Firmware version 1.02 gsm-x_sii_en 08/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk Poland tel. +48 58

More information

GSM communicator G16 USER MANUAL

GSM communicator G16 USER MANUAL USER MANUAL UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt Contents SAFETY REQUIREMENTS...2 DESCRIPTION...3 LIST OF COMPATIBLE CONTROL PANELS...3

More information

Network nodes with gateway

Network nodes with gateway 2 878 Siemeca AMR Network nodes with gateway WTX16.GSM WTX16.IP WTX16.MOD The WT 16 network nodes are used to receive and handle the data transmitted by consumption meters of the Siemeca AMR system. They

More information

Keypad LCD (software version 3.10) CA-10 plus

Keypad LCD (software version 3.10) CA-10 plus PROGRAMMING AND INSTALLATION MANUAL Keypad LCD (software version 3.10) CA-10 plus GDAŃSK ca10plci_e 09/03 WARNING Due to safety reasons, alarm system should be installed by qualified personnel only. Because

More information

Ethernet communicator E14 USER MANUAL July, 2018

Ethernet communicator E14 USER MANUAL July, 2018 USER MANUAL July, 2018 www.trikdis.lt UAB Trikdis Draugystės g. 17, LT-51229 Kaunas, Lietuva +370 37 408 040 info@trikdis.lt Contents SAFETY REQUIREMENTS... 3 1 DESCRIPTION... 4 1.1 List of Compatible

More information

Models: TD3000 Series. Table Displays. 2 by 20 character display USER MANUAL

Models: TD3000 Series. Table Displays. 2 by 20 character display USER MANUAL Models: TD3000 Series Table Displays 2 by 20 character display USER MANUAL i NOTICE The manufacturer of the POS table display makes no representations or warranties, either expressed or implied, by or

More information

APP 700 Technical Specification

APP 700 Technical Specification Issued: 12/12 Supersedes: 4/12 Description The APP 700 hardware series are especially designed for waste and clean water systems, both in construction and functionality. The RTUs¹ are developed to meet

More information

GSM communicator FireCom (v.1.61) User Manual and Installation Guide. Draugystes g. 17, LT Kaunas

GSM communicator FireCom (v.1.61) User Manual and Installation Guide. Draugystes g. 17, LT Kaunas GSM communicator FireCom (v.1.61) User Manual and Installation Guide Draugystes g. 17, LT-51229 Kaunas E-mail: info@trikdis.lt www.trikdis.lt Purpose of the document This document introduces the features

More information

Sensaphone SCADA 3000 APPLICATION SUPPORT BULLETIN Single-Frequency Radio

Sensaphone SCADA 3000 APPLICATION SUPPORT BULLETIN Single-Frequency Radio Sensaphone SCADA 3000 APPLICATION SUPPORT BULLETIN Single-Frequency Equipment requirements for a typical Sensaphone SCADA 3000 application using licensed, single-frequency radio modems. The purpose of

More information

Message Display Operator Panel. UCT-33/36 Industrial Terminal. Manual 32.00

Message Display Operator Panel. UCT-33/36 Industrial Terminal. Manual 32.00 BRODERSEN Message Displays/Operator Panels Message Display Operator Panel UCT-33/36 Industrial Terminal Manual 32.00 Brodersen Controls A/S. Betonvej 0. DK-4000 Roskilde. Denmark. Tel (+45) 46 74 00 00.

More information

PROGRAMMING AND INSTALLATION MANUAL

PROGRAMMING AND INSTALLATION MANUAL PROGRAMMING AND INSTALLATION MANUAL Keypad LCD-S (software version 3.10) CA-10 plus GDAŃSK ca10plci_s_e 09/03 WARNING Due to safety reasons, alarm system should be installed by qualified personnel only.

More information

Wing Watch Lite. Battery Monitoring System. User Manual

Wing Watch Lite. Battery Monitoring System. User Manual Wing Watch Lite Battery Monitoring System User Manual February 2009 Check the contents: The Wing Watch-Lite is packed in soft, protective material inside a carton box. There are 5 sets in each packaging.

More information

GSM communicator G10D

GSM communicator G10D D (v.1.xx) USER MANUAL UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt Description The communicator G10D is designed to transmit messages from

More information

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-10M Protection Switch January 2009 Rev O ALARMS MENU OUTPUT = CH1 AUTO POWER 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 CH2 REMOTE EXECUTE Data, drawings, and other

More information

Pulsar EXtreme 2000/3000 VA

Pulsar EXtreme 2000/3000 VA www.mgeups.com MGE UPS SYSTEMS Pulsar EXtreme 2000/3000 VA Installation and user manual P O W E R P R O V I D E R L E I B E R R U P T N T N I E U T H 51033211EN/AC - Page 1 Introduction Thank you for selecting

More information

AANDERAA. DATALOGGERS 3634 and 3660

AANDERAA. DATALOGGERS 3634 and 3660 DATALOGGERS 4 and 0 A rugged unit for reading standard Aanderaa sensors and for displaying, storing and transmitting the data in engineering units. Datalogger 4, channels Datalogger 0, 18 channels DATA

More information

Keypad LCD-L (software version 3.10) CA-10 plus

Keypad LCD-L (software version 3.10) CA-10 plus PROGRAMMING AND INSTALLATION MANUAL Keypad LCD-L (software version 3.10) CA-10 plus GDAŃSK ca10plci_l_e 09/03 WARNING Due to safety reasons, alarm system should be installed by qualified personnel only.

More information

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.4 UK

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.4 UK WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue

More information

ipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide

ipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide ipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications 2003 Control Technology

More information

AV-4000 GSM AV-4000 DVR

AV-4000 GSM AV-4000 DVR E a s y L o a d e r AV-4000 GSM AV-4000 DVR (for LED keypads) Integrated Alarm Control panel & Communicator Series 4000 Appendix for GSM Alarm Panels Version 1.05 Edition I This product is subject to continuous

More information

icp 1000 Wireless GSM Based Remote Monitoring Unit for Transformer Rectifier Unit

icp 1000 Wireless GSM Based Remote Monitoring Unit for Transformer Rectifier Unit icp 1000 Wireless GSM Based Remote Monitoring Unit for Transformer Rectifier Unit The GSM based remote monitoring unit icp 1000, for Transformer Rectifier (TR) monitoring, is a highly accurate, compact,

More information

3700 SERIES USER MANUAL

3700 SERIES USER MANUAL SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with

More information

Technical Documentation, RTCU-SA

Technical Documentation, RTCU-SA Technical Documentation, RTCUSA The RTCUSA product (GSM antenna not included in product) The RTCUSA product is a RTCU unit with a builtin communications module such as GSM, DECT or FSK Modem. The RTCUSA

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

Technical specification Marine Master Clock

Technical specification Marine Master Clock Page: 1 av 5 Technical specification Marine Master Clock 1 2 1 0 A MON 24 APR 2006 21.07:36 LT ALARM POWER RADIO LINK NO LT UTC LT General The master clock has 6 buttons and one (2 line x 16 character)

More information

HUAWEI FT2260 Home Phone Connect Quick Start

HUAWEI FT2260 Home Phone Connect Quick Start HUAWEI FT2260 Home Phone Connect Quick Start Introduction Top View The figures are only for your reference, the actual shape and color of the product may differ slightly. 7 8 9 10 1 2 3 4 5 6 1 Power on/off

More information

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display Installation Manual Model: HILU750 '' Ultra HD Interactive Flat Panel Display QUICK SETUP GUIDE For further information, see the User Manual. Please contact HITACHI directly if you have questions on the

More information

melabs Serial LCD Firmware Version 1.1 3/5/07

melabs Serial LCD Firmware Version 1.1 3/5/07 melabs Serial LCD Firmware Version 1.1 3/5/07 The melabs Serial LCD (SLCD) can display serial data from either asynchronous RS232-style or synchronous I 2 C input. A range of baud rates from 2400 to 57,600

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

melabs Serial LCD Firmware Version 1.0 2/7/07

melabs Serial LCD Firmware Version 1.0 2/7/07 melabs Serial LCD Firmware Version 1.0 2/7/07 The melabs Serial LCD (SLCD) can display serial data from either asynchronous RS232-style or synchronous I 2 C input. A range of baud rates from 2400 to 57,600

More information

IMMS-CELL-GSM. Cellular Communications Kit. Installation Instructions

IMMS-CELL-GSM. Cellular Communications Kit. Installation Instructions IMMS-CELL-GSM Cellular Communications Kit Installation Instructions TABLE OF CONTENTS... Before You Install... 1 Operating Systems: GSM, and GSM-E...2 Circuit Switched Data (CSD)...2 Installation Notes...

More information

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions. 55 This unit passes the following tests EN 61326-1:2006 (CISPR11,IEC/EN 61000-3-2:2006, IEC/EN 61000-3-3: 1995+A1 :2001+A2:2005 IEC/EN 61000-4-2/-3/-5/-6/-11) WARNING: Do not use the thermometer/data logger

More information

Rapidus Power Factor Controller

Rapidus Power Factor Controller Rapidus Power Factor Controller Moduler design No connector cables No fixing screws State of the art technology Easy mounting on panels connection to system Dynamic Capacitor Monitoring DCM is a supreme

More information

TECHNOLOGY, INC. ANAHEIM J CALIFORNIA FREEDOM AVE. [714]

TECHNOLOGY, INC. ANAHEIM J CALIFORNIA FREEDOM AVE. [714] TECHNOLOGY, INC. 165 FREEDOM AVE. ANAHEIM J CALIFORNIA 92801 [714] 992 2860 TABLE OF CONTENTS SECTION PAGE ONE 113 120 SPECIFICATION 1 TWO 113 120 FEATURES 3 THREE 113 120 OPERATION 5 FOUR PROGRAMMING

More information

HDT-318 Thermo-Hygrometer with Data Logger. (Air Humidity/Temperature) Instruction Manual

HDT-318 Thermo-Hygrometer with Data Logger. (Air Humidity/Temperature) Instruction Manual HDT-318 Thermo-Hygrometer with Data Logger (Air Humidity/Temperature) Instruction Manual CONTENTS 1. SAFETY INFORMATION... 2 2. GENERAL DESCRIPTION... 2 3. FEATURES... 2 4. SPECIFICATIONS... 3 5. SYMBOL

More information

QUICK START RF Monitor 4.3

QUICK START RF Monitor 4.3 QUICK START RF Monitor 4.3 Subject: NEWSTEO user guide for RF-Monitor software using Loggers (LOG, LGS, LGR) in Monitoring mode or Live/Record Mode Technical Assistance: For any question, remark or suggestion

More information

LED Wall Clock With Calendar and Temperature Display

LED Wall Clock With Calendar and Temperature Display User Manual LED Wall Clock With Calendar and Temperature Display XC-0239 Specifications: Remote Power: Remote Distance: Mounting holes: Power: Dimensions: 2 x AA Batteries (required) 8m Yes 9VDC Power

More information

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types Millenium 3 General Characteristics Millenium 3 Compact Range Millenium 3 Expandable Range Millenium 3 Communication Options Millenium 3 Range General environment characteristics for CB, CD, XD, XR and

More information

US-IP2. Monitoring Receiver

US-IP2. Monitoring Receiver US-IP2 Monitoring Receiver (and IP receiver card) Programming Manual 28 / 01 / 2014 CONTENT 1. INTRODUCTION...3 2. SYSTEM STRUCTURE...4 3. FIRST STEPS...4 Connectors and LED signals...5 4. SYSTEM PROGRAMMING

More information

Gas Controller System DGC-06

Gas Controller System DGC-06 Page 1 May 2016 Measuring, warning and controlling device series for toxic, combustible and refrigerant gases and vapours. The gas controller series DGC-06 is designed in accordance with the standard EN

More information

Safety and Maintenance You can use your Tablet PC under a wide range of environmental conditions. However, to ensure long use and continued high

Safety and Maintenance You can use your Tablet PC under a wide range of environmental conditions. However, to ensure long use and continued high EVG7 DL46 Getting Started Congratulations on your purchase of a Tablet PC. The Tablet PC is a fully functional PC with built-in LAN, and wireless connectivity. With your Tablet PC you will be able to organize

More information

ZCM-12, ZCM-12P/U TIME PROGRAMMER WEEK S, DOUBLE CHANNEL

ZCM-12, ZCM-12P/U TIME PROGRAMMER WEEK S, DOUBLE CHANNEL ZCM-12, ZCM-12P/U TIME PROGRAMMER WEEK S, DOUBLE CHANNEL INSTRUCTION MANUAL ZAMEL Sp. z o.o. ul. Zielona 27, 43-200 Pszczyna, Poland Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04 www.zamelcet.com, e-mail:

More information

TS-ADA-029. Wireless Tone Generator. User's Manual / Installation Guide. Version 1.03

TS-ADA-029. Wireless Tone Generator. User's Manual / Installation Guide. Version 1.03 TS-ADA-029 Wireless Tone Generator User's Manual / Installation Guide Version 1.03 Visiplex, Inc. 2012 TS-ADA-029 Wireless Tone Generator Copyright The product described in this manual includes copyrighted

More information

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A Table of Contents 1. Important Safety Instructions... 2 2. Overview... 3 3. Product Functional Description... 4 3.1. Front Panel... 4 3.2. LCD Display Description... 5 3.3. Rear Panel... 6 3.4. Communication

More information

WaterCress Portfolio

WaterCress Portfolio WaterCress Portfolio The WaterCress Solution Option: X WaterCress Hardwired RS485 Comms Hard Wired Relay Outputs Sensor Minimum: 2 per card Maximum: 8 per card Radio Option: W WaterCress Wireless FM RS485

More information

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual Version 2.1 Gamma Scale Tel: (905) 455-8333 Fax: (905) 455-0658 E-mail: info@gammascale.com Website: www.gammascale.com 1. Technical Parameters

More information

Centralised monitoring software. (version v2.35) Program installation and configuration

Centralised monitoring software. (version v2.35) Program installation and configuration Centralised monitoring software (version v2.35) Program installation and configuration The purpose of the document This document describes the installation and configuration process of program package

More information

FG-3000R Digital Force Gauge Operation Manual

FG-3000R Digital Force Gauge Operation Manual FG-3000R Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,

More information

Clear Benefits of the KRAL Electronic.

Clear Benefits of the KRAL Electronic. Clear Benefits of the KRAL Electronic. Coordinated to the flowmeters and their applications. Users of conventional universal display units often cannot make use of their device s options. There is often

More information

SCROLL GAS PRICE DISPLAY SYSTEM ROS SERIES INSTALLATION MANUAL REV 3.0

SCROLL GAS PRICE DISPLAY SYSTEM ROS SERIES INSTALLATION MANUAL REV 3.0 SCROLL GAS PRICE DISPLAY SYSTEM ROS SERIES INSTALLATION MANUAL REV 3.0 Fax: (514) 683-0068 Rev : 3.0 www.novyc.com Page 1 of 11 WARNING The ROS Scroll Display System must be installed as per Novyc International's

More information

Table of Contents. Table of Contents... 2 What s new in version 1.50? Introduction Quick Start Installation...

Table of Contents. Table of Contents... 2 What s new in version 1.50? Introduction Quick Start Installation... User Manual Table of Contents Table of Contents... 2 What s new in version 1.50?... 4 1. Introduction... 5 CPM Unit... 5 Line Cards... 5 Power Module... 5 Compatibility... 5 System Overview... 6 2. Quick

More information

FG-3000 Digital Force Gauge Operation Manual

FG-3000 Digital Force Gauge Operation Manual FG-3000 Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,

More information

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3 THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL Digi-modems Issue 3 Contents Com300 & Com2400 Installation Manual Contents 1. Regulatory Requirements... 3 General...3 Approval... 3 REN Rating... 3 2.

More information

SATA DVD/CD Duplicator Controller User s Manual

SATA DVD/CD Duplicator Controller User s Manual SATA DVD/CD Duplicator Controller User s Manual Version 2.0 TABLE OF CONTS Chapter 1 Introduction 1 10. Setup 11 11. HDD Manager 13 LCD Front Panel Overview 1 o Start-up Menu 11 o Select Image 13 Hardware

More information

Digital Signal Level Meters. IT-910C Series. User Manual

Digital Signal Level Meters. IT-910C Series. User Manual Digital Signal Level Meters IT-910C Series User Manual Revision History Revision Description Date Author 01 Created 2014-9-18 INOTECH SHEET 2 OF 11 Content 1. Note... 4 2. Product Description... 5 2.1

More information

AC5160 SiPass integrated controller kit

AC5160 SiPass integrated controller kit AC5160 SiPass integrated controller kit SiPass integrated Wall housing with pre-assembled basic SiPass integrated components Equipped with one ACC (AC5100), two dual reader interfaces (ADD5100) and one

More information

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems Features General Universal Application Data Processing Telecommunications Medical/Health Care Manufacturing/ Process Control Quality Design

More information

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES 2 power sources automatic transfer switch controllers The automatic transfer switch controllers ATL 600 - ATL 610 - ATL 800 can supervise and manage the

More information

Millenium 3 logic controllers

Millenium 3 logic controllers Millenium 3 logic controllers Type Part number Power supply Inputs Outputs With display Without display CD12 88970041 24 V c 8 digital (of which 4 are analogue) 4 x 8 A relays 88970042 24 V c 8 digital

More information

Features. Reliable High RF Shielding. Pneumatic control of lid open-close and optional test fixture motions

Features. Reliable High RF Shielding. Pneumatic control of lid open-close and optional test fixture motions TC-5972AP/CP Pneumatic Shield Box Features Reliable High RF Shielding Pneumatic control of lid open-close and optional test fixture motions Easily customizable to meet various test needs Shock Absorbers

More information

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual Vorne Industries 2000S Series Serial Input Alphanumeric Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 Telephone (630) 875-3600 Telefax (630) 875-3609 2000S Series Serial Input Alphanumeric

More information

H3G-380 Production Description

H3G-380 Production Description H3G-380 Production Description Designed for UPS battery strings of 15 to 48 batteries each of VRLA and Ni-Cd battery 1 Applications For strings of 15 to 48 batteries each Data Center IT Data Room 2 Product

More information

BACnet. b3810 Series Local Controllers

BACnet. b3810 Series Local Controllers BACnet b380 Series Local Controllers The Andover Continuum TM b380 series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. 0 Features Choose

More information

T.E.L.L. DR Digital Receiver. User Manual. CPM2 V2.20 build A430 LC2 V2.20 build A426

T.E.L.L. DR Digital Receiver. User Manual. CPM2 V2.20 build A430 LC2 V2.20 build A426 T.E.L.L. DR-81000 Digital Receiver User Manual CPM2 V2.20 build A430 LC2 V2.20 build A426 Table of Contents Table of Contents... 2 1. Introduction... 5 CPM2 Card...5 LC2 Line Cards...5 PWR2 Power Card...5

More information

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control VISTA 12a / 48a TECHNICAL TRAINING The Best in Security plus Everyday Convenience & Control Version #.007 7th June 2005 VISTA 12a / 48a Training Guide Index 1. Vista Family Features....... p. 3 2. Wiring

More information

DMX-DALI-DMX interface

DMX-DALI-DMX interface PX 255 DMX-DALI-DMX interface MANUAL R CONTENTS 1. General description... 3 2. Safety conditions... 3 3. Connections and control elements description... 4 4. Navigating the menu... 4 5. Use of the device...

More information

GCR 06, GCR 12. Power factor correction controller. User and service manual

GCR 06, GCR 12. Power factor correction controller. User and service manual GCR 06, GCR 12 Power factor correction controller User and service manual version 1.6 Czech Republic Czech Republic 1 Content 1. Front control panel and back terminal panel...3 2. Device description...

More information

FG-7000 Digital Force Gauge Operation Manual

FG-7000 Digital Force Gauge Operation Manual FG-7000 Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,

More information

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0 VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0 1. Installation Requirements 1.1. PC Pentium III processor or higher. Minimum RAM memory: 128 Mbytes Operating system: Windows XP

More information

QIT600F1 USER'S GUIDE

QIT600F1 USER'S GUIDE QIT600F1 USER'S GUIDE 1 IMPORTANT SAFEGUARDS Warnings: 1. Read all of these instructions. Save these instructions for later use, please. 2. Unplug this monitor from the wall outlet before cleaning. Do

More information

CONVENIENT INSTALLATION For installation convenience, the SG-SLR is packaged in a desktop Card Cage.

CONVENIENT INSTALLATION For installation convenience, the SG-SLR is packaged in a desktop Card Cage. INTRODUCING THE The is a Single-Line, Multi-Format Digital Receiver designed to interpret a variety of communications formats for the ultimate in convenience and versatility. The will provide features

More information

16COM / 40SEG DRIVER & CONTROLLER FOR DOT MATRIX LCD

16COM / 40SEG DRIVER & CONTROLLER FOR DOT MATRIX LCD INTRODUCTION KS0066U is a dot matrix LCD driver & controller LSI whichis fabricated by low power CMOS technology It can display 1or 2 lines with the 5 8 dots format or 1 line with the 5 11 dots format

More information

IP68. Autarkic Data Loggers - MT-051 / MT-713 / MT-723

IP68. Autarkic Data Loggers - MT-051 / MT-713 / MT-723 Autarkic Data Loggers - MT-051 / MT-713 / MT-723 Use in the most demanding environments These data loggers are designed for use in difficult to reach and widely distributed locations. In places where neither

More information

SENECA s.r.l. Commercial

SENECA s.r.l. Commercial INSTALLATION MANUAL EN Serie Z PC INDUSTRIAL MODEM /GPRS Quadband CHAPTER INDEX 1. PRELIMINARY WARNINGS 2. DESCRIPTION AND CHARACTERISTICS 2.1 Module description 2.2 General characteristics 3. TECHNICAL

More information

BACnet. b3867 Terminal Controllers

BACnet. b3867 Terminal Controllers BACnet b3867 Terminal Controllers The Andover Continuum TM b3867 is a native BACnet controller that communicates on an RS-485 field bus as a Master device using the MS/TP BACnet protocol. 02 Features Product

More information

AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS

AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS FN:XXMFCT1.DOC AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS REV 04/09/09 DESCRIPTION The AEXX Series of Multi-Function Clock/Timers are available with 1, 2.3, 4, 8, or

More information

USER GUIDE. Preliminary

USER GUIDE. Preliminary USER GUIDE Preliminary Copyright 2009, NITGEN&COMPANY Co., Ltd. All rights reserved. ` Unauthorized reproduction of part or all of this manual s content in any form is prohibited. Product specifications

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range MSR 2400W Multi purpose Power System for Telecom and Industrial Applications 2400 W modular system All voltages available 0 144VDC per module U and I adjustable from 0 to max value Hot-swap plug-in modules

More information

CONTROL SYSTEMS. MultiBasic Blue MultiBasic MultiClassic MultiPro. Overview. Execution TA. Execution FL. Type

CONTROL SYSTEMS. MultiBasic Blue MultiBasic MultiClassic MultiPro. Overview. Execution TA. Execution FL. Type MultiBasic Blue MultiBasic MultiClassic MultiPro CONTROL SYSTEMS Overview Execution TA Execution FL > MultiBasic Blue Nutrunners of type SA - > MultiBasic Nutrunners of type SA - > MultiClassic Nutrunners

More information

Analog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules

Analog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules Analog Input Modules Analog Current Input - 16 Channel IC693ALG223 The 16-Channel Analog Current Input module provides up to 16 single-ended input channels, each capable of converting an analog input signal

More information

Model ST-FT1 DIGITAL FORCE / TORQUE INDICATOR. User s Guide

Model ST-FT1 DIGITAL FORCE / TORQUE INDICATOR. User s Guide Model ST-FT1 DIGITAL FORCE / TORQUE INDICATOR Thank you Thank you for purchasing a Mesa Labs Model ST-FT1 digital force / torque indicator, designed for use with a remote torque sensor. With proper usage,

More information

USER GUIDE. 3 Channel DC Current Datalogger Model SD900

USER GUIDE. 3 Channel DC Current Datalogger Model SD900 USER GUIDE 3 Channel DC Current Datalogger Model SD900 Table of Contents 1. INTRODUCTION 3 2. DESCRIPTIONS 4 3. OPERATION 5 Power 5 Connecting Current Cables 5 Datalogging 5 Time/Date/Sample Rate Check

More information

TELTONIKA ModemCOM (TMC-10x) User Manual V

TELTONIKA ModemCOM (TMC-10x) User Manual V TELTONIKA ModemCOM (TMC-10x) User Manual V2.1.1.18 TABLE OF CONTENTS ATTENTION!...3 LEGAL NOTICE...3 INTRODUCTION...4 1. PACKAGE CONTENTS...5 2. TECHNICAL SPECIFICATIONS...6 2.1. Data transferring...6

More information