Osisense XML. Electronic Pressure Sensors. Catalog

Size: px
Start display at page:

Download "Osisense XML. Electronic Pressure Sensors. Catalog"

Transcription

1 Osisense XML Electronic Sensors Catalog Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

2 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

3 Contents Selection Guide b Selecting a Switch electronic pressure sensors b General Overview b Terminology b XMLK pressure transmitters: v Introduction v Specifi cations v Selection and Specifi cations v Accessories and Wiring v Dimensions b XMLG pressure transmitters and pressure/vacuum switches: v Introduction v Specifi cations v Selection and Specifi cations v Accessories and Replacement Parts v Dimensions and Wiring b XMLF pressure sensors: v Introduction v Specifi cations v Selection and Specifi cations v Accessories and Replacement Parts v Dimensions and Wiring b XMLE pressure transmitters and pressure switches: v Introduction v Specifi cations v Selection and Specifi cations v Accessories v Dimensions and Wiring Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

4 Selection Guide Applications Type of installation Control circuits Fluids controlled Type of sensor and features Air, fresh water Units without display transmitters Analog output, 0 ma or 0 0 V Applications: pumping Fluid characteristics Air, fresh water, 0 to + 80 C (.0 to.0 F) Sizes 0 to (0 to 00 psi) Dimensions of case mm (in.) Width x height x depth Ø x. (Ø.0 x.0) Type of output Analog, 0 ma or 0 0 V Degree of protection IP conforming to IEC/EN0, NEMA Electrical connection M, DIN 0 A or Delphi (Packard) Metri-Pack connector () Fluid connection G / A (male) conforming to ISO or /"-8 NPT male () Catalog number XML KpppBCpp, XML KpppBCppTQ () XML KpppBDpp, XML KpppBDppTQ () XML KpppPCpp, XML KpppPCppTQ () XML KpppPDpp, XML KpppPDppTQ () XML KpppPPpp, XML KpppPPppTQ () Pages Other versions () For other connections (such as AMP connector or cable), consult the Sensor Competency Center at () Phoenix Contact QUICKON type integrated connection. () For other fl uid connections (such as G / A BSP male or /" NPTF female), refer to Interpretation of the Catalog Number on page, or consult the Sensor Competency Center at Component materials of units in contact with the fl uid: see page. () Sold in lots of, with a minimum order of 0 pcs. 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

5 Control circuits Air, water, hydraulic oils, corrosive fluids Units without display transmitters Analog output 0 ma or 0 0 V Air, fresh water Units without display and vacuum switches Factory set switching thresholds Solid-state NPN or PNP output Air, fresh water, sea water, hydraulic oils, corrosive fl uids, to + C (.0 to.0 F) Air, fresh water, sea water, hydraulic oils, corrosive fl uids, to + C (.0 to.0 F) to 00 (. to 800 psi) to 00 (. to 800 psi) Ø.8 x 0. (Ø 0.0 x.) Ø.8 x 8 (Ø 0.0 x.) Ø.8 x 0. (Ø 0.0 x.) Ø.8 x 8 (Ø 0.0 x.) Analog, 0 ma or 0 0 V IP, IP conforming to IEC/EN0, NEMA Solid-state, PNP or NPN normally closed (NC) output 0 ma, / Vc IP, IP conforming to IEC/EN0, NEMA M connector () Integrated quick connection () M connector () Integrated quick connection () /" NPT male conforming to ISO () /" NPT male conforming to ISO () XMLGpppD XMLGpppDppTQ () XMLG pppd XMLG pppdtq () XMLGpppQppTQ () XMLGpppDppTQ () XMLGpppDppTQ () XMLGpppQppTQ () XMLGpppQppTQ () 8 () For other connections (such as AMP connector or cable), consult the Sensor Competency Center at () Phoenix Contact QUICKON type integrated connection. () For other fl uid connections (such as G / A BSP male or /" NPTF female), refer to Interpretation of the Catalog Number on page, or consult the Sensor Competency Center at Component materials of units in contact with the fl uid: see page. () Sold in lots of, with a minimum order of 0 pcs. 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

6 Selection Guide Applications Type of installation Control circuits Fluids controlled Air, water, hydraulic oils, corrosive fluids Type of sensor and features Configurable units with digital display transmitters Output current 0 ma transmitters Output voltage 0 0 V Universal sensors Regulation between thresholds (adjustable differential) Solid-state and analog output current 0 ma Fluid characteristics Air, fresh water, sea water, hydraulic oils, corrosive fl uids, to +80 C (.0 to.0 F) Sizes Dimensions of case mm (in.) to 00 (. to 800 psi) Width x height x depth x x 8 (.8 x. x.8) Type of output Analog, 0 ma Analog, 0 0 V Solid-state, PNP or NPN, 00 ma, Vc output Analog output 0 ma Degree of protection IP Electrical connection Fluid connection M connector G / A (BSP) or /" NPT or SAE /-0 UNF female Catalog number XMLFpppD0p XMLFpppDp XMLFpppD0p Pages 8 Other versions For pressure transmitters, electronic pressure switches, and vacuum switches with alternative tapped fl uid entries, consult the Sensor Competency Center at Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

7 Control circuits Air, water, hydraulic oils, corrosive fluids Configurable units with digital display Units without display Universal sensors Regulation between thresholds (adjustable differential) Solid-state and analog output voltage 0 0 V Dual stage pressure and vacuum switches (solidstate outputs) Detection of thresholds and adjustable differential for each threshold and vacuum switches with. A relay outputs Regulation between thresholds (adjustable differential) transmitters Analog output 0 ma and vacuum switches with solid-state output Regulation between thresholds (adjustable differential) Air, fresh water, sea water, hydraulic oils, corrosive fl uids, to +80 C (.0 to.0 F) Air, fresh water, sea water, hydraulic oils, corrosive fl uids, to +80 C (.0 to.0 F) to 00 (. to 800 psi) to 00 (. to 800 psi) x x 8 (.8 x. x.8) x x 8 (.8 x. x.8) sizes to : Ø 0 x 8 (Ø. x.) sizes 0 to 00 : Ø 0 x (Ø. x.8) Solid-state, PNP or NPN, 00 ma, Vc output Analog output 0 0 V solid-state, PNP or NPN, 00 ma, Vc outputs Relay output. A, 0 Va Analog, 0 ma Solid-state, NPN or PNP, normally closed (NC) output IP IP M connector SAE /8-UN connector DIN 0A or M connector G / A (BSP) or /" NPT or SAE /-0 UNF female /" NPT male, G / A (BSP) male XMLFpppDp XMLFpppD0p XMLFpppE0p XMLEpppppp XMLEpppppp XMLEpppppp 8 8 For pressure transmitters, electronic pressure switches, and vacuum switches with alternative tapped fl uid entries, consult the Sensor Competency Center at Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

8 Selecting a Switch Fixed differential PH Adjustable differential PH PB Steps for Selecting a Switch Catalog Choose : > > > > > 8 > > 0 > Number Setpoints > Fluids The deciding factors in the selection of a pressure switch for use on control circuits depend on the requirements of the application. Consider the following requirements to help determine the appropriate catalog number for your application.. Setpoints: Do you want to control/monitor one setpoint or two? One setpoint: fi xed differential Two setpoints: adjustable differential. Fluids: What fluids do you want to control? Hydraulic oil, air, fresh water 0 C (8 F) Steam Hydraulic oil, air, fresh water 0 C (0 F) Corrosive fl uid 0 C (0 F) Sea water 0 C (8 F) Viscous fl uid 0 C (0 F) Sea water 0 C (0 F) Ensure that the wetted parts of the switch are compatible with the system fl uid.. Range: What pressure range does the system experience? Note: Select pressure settings that fall within the middle 80% of the pressure range. The pressure applied during a normal cycle should never exceed the maximum range value listed for the switch. surges should be less than the maximum allowable pressure listed for the switch. Rated psi 0 to 0. 0 to to.0 0 to 0.. to.0 to 0.8. to.0 to 0.. to to 0.0. to. 0. to 0 to. 0 to 0 to. 0 to. 0 to 8 0 to 0 to 0 to 0 0 to 0 0 to 0 0 to 0. 0 to 0 to 80 0 to 0 0 to 0 0 to 0 0 to 0 0 to 0 0 to 0 0 to 00 0 to 0 0 to 00 Range Surges > Enclosure Output Electrical Connection Fluid Connection Special Features System Response. Surges: How frequent are surges in your system, and what is their maximum pressure level? Applications experiencing frequent or high-pressure surges may require a device with a higher pressure range. 0 For switches used on power circuits, see catalog 0CT0, Commercial Switches, Class 0 Types F and G. 8 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

9 Selecting a Switch (continued). Enclosure: What degree of enclosure protection do you need? IP IP IP. Output: What type of output do you require? Analog, 0 ma DC Analog, 0 ma, shunt calibration Solid State, NPN DC Analog, 0 ma digital single stage Solid State, PNP DC Analog, 0 0 V, shunt calibration Analog, 0 0V DC Analog, 0 0 V, digital single stage AC Relay 0V DC digital dual stage. Electrical Connection: What type of electrical connection do you require? M DIN 0A Integrated quick connect /8 UNA Delphi (Packard) Metri-Pack. Connection: What type of pressure connection do you require? ¼"- 8 NPTF (female) G / BSP (female) metric thread ½" - NPT /"-0 UNF-B. Special Features: Do you require any special features? When switches must be factory set and only one setting is identifi ed, specify whether this setting is on rising or falling pressure. State the switching threshold settings when ordering. 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

10 General Overview For control circuits Functions transmitters The function of pressure transmitters is the control and measurement of pressure or vacuum levels in hydraulic or pneumatic systems. They transform the pressure into an analog electrical signal which is proportional to the pressure measured. Their high precision makes them suitable for all industrial applications requiring pressure/vacuum display, control, or regulation. Also very robust, they are equally suitable for applications involving high operating rates. and vacuum switches The function of electronic pressure and vacuum switches is the control or regulation of pressure or vacuum levels in hydraulic or pneumatic systems. They transform the pressure change into a digital output signal when the preset pressure or vacuum points are reached. The very wide adjustment range for the setpoints characterize these electronic switches. Their robustness, along with their excellent adherence to the set values over time, make them ideal for applications involving high operating rates. In addition, the high repeat accuracy and fast response time of these sensors make them equally suitable for applications requiring accurate pressure regulation and monitoring. Universal sensors Universal sensors are electronic pressure and vacuum switches with digital output, which also include an analog output identical to that of the pressure transmitters. Operating principle transmitters The electrical signal from the pressure transmitter (signal proportional to the monitored pressure) is amplifi ed, calibrated, and output as a standard 0 ma or 0 0 V analog signal (depending on the model). 0 ma or 0 0 V Signal Operating range 0 and vacuum switches Designed for regulation between thresholds, these switches have both a high setpoint (PH) and a low setpoint (PB). Both of these points can be independently adjusted (adjustable differential). The difference (differential) between the two setpoints can be small or large. Since the switches are electronic, they have no mechanical moving parts. Operating principle with solid-state NC outputs switches with digital Vacuum switches with digital output output Output on Output off Dual stage pressure switches PH Adjustable differential PB PH PB PH PB Adjustable value PH = high setpoint PB = low setpoint Adjustable differential Adjustable differential Vacuum Output on Output off PH Adjustable differential PB Adjustable value PH = high setpoint st stage PB = low setpoint st stage PH = high setpoint nd stage PB = low setpoint nd stage Output st stage on Output st stage off Output nd stage on Output nd stage off 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

11 General Overview (continued) For control circuits Terminology Measuring range The measuring range (MR) of a pressure sensor corresponds to the difference between the upper and lower values measured by the load cell. It ranges between 0 and the pressure corresponding to the size of the sensor. Operating range The operating range of a pressure transmitter corresponds to its measuring range. Within this range, its analog output signal varies between and 0 ma or 0 and 0 V, and is proportional to the measured pressure. The operating range of a pressure or vacuum switch is the difference between the values of the minimum low setpoint (PB) and the maximum high setpoint (PH). Precision This includes linearity, hysteresis, repeat accuracy, and setting tolerances. It is expressed as a percentage of the measuring range of the load cell (%MR). Signal The linearity is the maximum deviation between the real transmitted curve and the ideal curve. Signal The hysteresis is the maximum deviation between the rising pressure curve and the falling pressure curve. Signal The repeat accuracy is the maximum drift encountered at varying pressures under given conditions. Signal Signal The setting tolerances are the manufacturer s tolerances with regard to the zero point and sensitivity (gradient of output signal curve from pressure transmitter). Temperature drift The precision of a pressure sensor is susceptible to variation due to the operating temperature. Signal t t Zero point drift, proportional to the temperature, is expressed as %MR/ C. Signal t t Sensitivity drift, proportional to the temperature, is expressed as %MR/ C. 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

12 General Overview (continued) For control circuits + Setting point R Terminology (continued) Switching point on rising pressure (PH) This is the upper pressure setting at which the output of the electronic pressure or vacuum switch changes state on rising pressure. Switching point on falling pressure (PB) This is the lower pressure setting at which the output of the electronic pressure or vacuum switch changes state on falling pressure. Differential This is the difference between the switching point on rising pressure (PH) and the switching point on falling pressure (PB). The low point can be set at the values indicated on the operating curves shown on the product pages. Switches with fixed differential Depending on the switch, either the high or low operating point is adjustable, and the other operating point follows. The window is fi xed. Switches with adjustable differential An adjustable differential allows independent setting of both operating points. Spread For dual-stage switches, the spread indicates the difference between the two operating points on rising pressure (PH and PH) and, for vacuum switches, the difference between the two operating points on falling pressure (PB and PB). Differential- Sensing Switches for differential-pressure sensing measure the difference between two pressures. Size transmitters and pressure switches This is the maximum value of the operating range. Vacuum transmitters and vacuum switches This is the minimum value of the operating range. Accuracy (switches with setting scale) The tolerance between the point at which the switch actuates its contacts and the value indicated on the setting scale. Where very high setting accuracy is required (initial installation of the product), it is recommended to use separate measuring equipment (pressure gauge, etc.). Repeat accuracy This is the variation of the operating point of the pressure or vacuum switch between several successive operations, or the tolerance between two consecutive switching operations. F Drift (F) The tolerance of the operating point throughout the entire service life of the switch. 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

13 General Overview (continued) For control circuits Terminology (continued) Maximum allowable pressure The maximum value of an accidental pressure surge of very short duration (a few milliseconds) ms ms Example : With destructive (burst) pressure level Without damping device With damping device Example : With destructive (burst) pressure level and destructive pressure oscillations Maximum permissible accidental pressure This is the maximum pressure (excluding pressure surges) that the sensor can occasionally withstand without permanent damage. Maximum allowable pressure per cycle (Ps) The maximum pressure level per cycle that the switch can withstand for optimum service life. Surge A surge is a high rate of rise in pressure, normally of short duration, caused by starting a pump or by opening and closing a valve. Depending on frequency and duration, surge can reduce service life. Extremely high rates of rise in pressure can be damaging even if they are within the limits of the maximum allowable pressure. Destruction pressure Also called burst pressure, the destruction pressure is the pressure value which, if exceeded, is likely to cause serious damage to the sensor such as leaking, bursting, or permanent damage. Load resistance of pressure transmitters The supply voltage and load resistance of a pressure transmitter must be selected according to the following formula: R load = U supply U supply min. (U supply min = V for XMLE and V for XMLF) 0.0 A 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

14 Introduction XMLK pressure transmitters For control circuits Introduction Type XMLK pressure transmitters are characterized by their ceramic pressuremeasuring cell. Deformation, caused by pressure, changes the resistance of the resistors of a Wheatstone bridge silk-screened on the ceramic. The change in resistance is then processed by the integrated electronics to provide an analog output signal. Electrical connection: for example, DIN EN 0-80-A connector Seals Threaded fl uid connection Hybrid electronics Ceramic measuring cell Functions XMLK pressure transmitters have an analog output, 0 ma or 0 0 V, which is proportional to the measuring range. These compact products are available with various types of electrical connectors and fl uid connections. Standard versions are available calibrated in both and psi. The bulk packaging alternative offers an excellent price/performance ratio. XMLK electronic pressure sensors are designed for simple pumping applications and are well suited for pump equipment manufacturers. 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

15 Specifi cations XMLK pressure transmitters For control circuits Environmental Specifications Conformity to standards Product certifications e IEC/EN 0-, IEC/EN 0-- EN 008-, EN 008-, EN UL: File E, CCN NKPZ CSA: File 0, Class -0 Rated supply voltage V V c Voltage limits 0 ma: 8 V c 0 0 V:. V c Current consumption 0 ma: < 0 ma 0 0 V: < ma Output signal 0 ma, 0 0 V Protective treatment Standard version TC Ambient air temperature For operation C ( F) 0 to + 80 ( to ) For storage C ( F) to + 8 ( to 8) Fluids or products controlled Air, fresh water (0 to + 80 C / to F) Component materials in contact with fluid Steel, type AISI 0 (stainless steel) nitrile (NBR) Operating position All positions Vibration resistance 0 gn ( 000 Hz) conforming to IEC Shock resistance gn (half sine wave ms) conforming to IEC Resistance to Electrostatic discharges Standard EN 000--, 8 kv in air, kv on contact electromagnetic interference Radiated electromagnetic fi elds Standard EN 000--, >0 V/m, MHz Fast transients Standard EN 000--, kv Surges Standard EN 000--, 00 V Ω, kv Ω Conducted disturbances, Standard EN 000--, 0 V MHz induced by radio frequency fi elds Magnetic fi elds Standard EN , 0 A/m, 0 Hz Electrical protection Protected against reverse polarity and load short-circuit. For use on Class circuit. Rated impulse withstand voltage kv 0. Degree of protection IP conforming to IEC/EN 0, NEMA Output response time ms < Repeat accuracy ± 0.% of the measuring range Precision (resolution) Combined sum of linearity, hysteresis, and repeat accuracy <± 0.% of the measuring range Setting tolerance of zero point and measuring range limit < ± % of the measuring range Drift Of the zero point < ± 0.0% of the measuring range/ K Of the sensitivity < ± 0.0% of the measuring range/ K Service life Operating cycles > 0 million (varies based on application and environment) Fluid connection G / A (male) conforming to ISO, or /"-8 NPT male Electrical connection Connector, either M, DIN 0A (DIN EN 0-80-A) or Delphi (Packard) Metri-Pack Interpretation of the catalog number Note: Use this table only to interpret the catalog number. Some combinations are not available. XMLK 00 P D TQ Units without display Rated pressure Unit of O-Ring Electrical Output Fluid connection Bulk pack mm (. in.) diameter Code psi pressure connection 00 0 B: : NBR (Nitrile) C: DIN 0A : Analog, 0 ma : G / A (male) P: psi D: M : Analog, 0 0 V : /"-8 NPT (male) 0 0 P: Delphi (Packard) Metri-Pack Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

16 Selection and Specifi cations XMLK pressure transmitters, version With analog output 0 ma Sizes 0 to (0 to psi) transmitters type XMLK, version, DIN 0A connector or M connector () DIN 0A connector M connector range 0 (0 8 psi) 0 0 (0 psi) 0 (0 psi) 0 (0. psi) Selection transmitters XMLK, DIN 0A connector Sold in packs of: XMLK00BC XMLK00BC XMLK0BC XMLK0BC bulk () XMLK00BCTQ XMLK00BCTQ XMLK0BCTQ XMLK0BCTQ transmitters XMLK, M connector Sold in packs of: XMLK00BD XMLK00BD XMLK0BD XMLK0BD Fluid connection () bulk () XMLK00BDTQ XMLK00BDTQ XMLK0BDTQ XMLK0BDTQ G / A (male) Weight, kg (lb) 0.0 (.) 0.0 (.) 0.0 (.) 0.0 (.) Additional specifications not shown under general specifications Rated supply voltage Voltage limits Output () Current consumption V c 8 V c 0 ma, -wire technique < 0 ma Maximum permissible accidental pressure ( psi) 0 (0 psi) ( psi) 0 ( psi) Destruction pressure 8 ( psi) 0 ( psi) 8 ( psi) (08. psi) Electrical connection DIN 0A connector EN 0-80-A (male). For suitable female connector see accessories on page 0. M connector M, -pin male. For suitable female connectors, including pre-wired versions, see accessories on page 0. () For other types of electrical connections, consult the Sensor Competency Center at () Sold in lots of, minimum quantity 0. () For other types of fl uid connections, consult the Sensor Competency Center at () For other types of output, consult the Sensor Competency Center at Output curve XMLK0ppBp Connector wiring: -wire technique ( 0 ma) Is (ma) DIN M 0 Input + + Output % 00 % P () 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

17 Selection and Specifi cations (continued) XMLK pressure transmitters, version With analog output 0 0 V Sizes 0 to (0 to psi) transmitters type XMLK, version, DIN 0A connector or M connector () DIN 0A connector M connector range 0 (0 8 psi) 0 0 (0 psi) 0 (0 psi) 0 (0. psi) Selection transmitters XMLK, DIN 0A connector Sold in packs of: XMLK00BC XMLK00BC XMLK0BC XMLK0BC bulk () XMLK00BCTQ XMLK00BCTQ XMLK0BCTQ XMLK0BCTQ transmitters XMLK, M connector Sold in packs of: XMLK00BD XMLK00BD XMLK0BD XMLK0BD Fluid connection () bulk () XMLK00BDTQ XMLK00BDTQ XMLK0BDTQ XMLK0BDTQ G / A (male) Weight, kg (lb) 0.0 (.) 0.0 (.) 0.0 (.) 0.0 (.) Additional specifications not shown under general specifications Rated supply voltage V c Voltage limits Output () Current consumption. V c 0 0 V, -wire technique < ma Maximum permissible accidental pressure ( psi) 0 (0 psi) ( psi) 0 ( psi) Destruction pressure 8 ( psi) 0 ( psi) 8 ( psi) (08. psi) Electrical connection DIN 0A connector EN 0-80-A (male). For suitable female connector see accessories on page 0. M connector M, -pin male. For suitable female connectors, including pre-wired versions, see accessories on page 0. () For other types of electrical connections, consult the Sensor Competency Center at () Sold in lots of, minimum quantity 0. () For other types of fluid connections, consult the Sensor Competency Center at () For other types of output, consult the Sensor Competency Center at Output curve XMLK0ppBp Connector wiring: -wire technique (0 0 V) Us (V) 0 DIN M Input + + Output 0 0 % 00 % P () 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

18 Selection and Specifi cations (continued) XMLK pressure transmitters, psi version With analog output 0 ma Sizes 0 to 00 psi (0 to 0. ) transmitters type XMLK, psi version, DIN 0A, M or Metri-Pack connector () DIN 0A connector M connector Metri-Pack connector range 0 00 psi (0. ) 0 0 psi (0 0. ) 0 00 psi (0.8 ) 0 00 psi (0.0. ) Selection transmitters XMLK, DIN 0A connector Sold in packs of: XMLK00PC XMLK0PC XMLK00PC XMLK00PC bulk () XMLK00PCTQ XMLK0PCTQ XMLK00PCTQ XMLK00PCTQ transmitters XMLK, M connector Sold in packs of: XMLK00PD XMLK0PD XMLK00PD XMLK00PD bulk () XMLK00PDTQ XMLK0PDTQ XMLK00PDTQ XMLK00PDTQ transmitters XMLK, Metri-Pack connector Sold in packs of: XMLK00PP XMLK0PP XMLK00PP XMLK00PP Fluid connection () bulk () XMLK00PPTQ XMLK0PPTQ XMLK00PPTQ XMLK00PPTQ /"-8 NPT male Weight, kg (lb) 0.0 (.) 0.0 (.) 0.0 (.) 0.0 (.) Additional specifications not shown under general specifications Rated supply voltage V c Voltage limits Output () Current consumption 8 V c 0 ma, -wire technique < 0 ma Maximum permissible accidental pressure 00 psi (.8 ) 00 psi (0. ) 00 psi (. ) 00 psi ( ) Destruction pressure 00 psi (0. ) 0 psi ( ) 00 psi ( ) 00 psi ( ) Electrical connection DIN 0A connector EN 0-80-A (male). For suitable female connector see accessories on page 0 M connector M, -pin male. For suitable female connectors, including pre-wired versions, see accessories on page 0. Metri-Pack connector -pin Delphi (Packard) Metri-Pack 0 series. () For other types of electrical connections, consult the Sensor Competency Center at () Sold in lots of, minimum quantity 0. () For other types of fluid connections, consult the Sensor Competency Center at () For other types of output, consult the Sensor Competency Center at Output curve XMLKppPp Connector wiring: -wire technique ( 0 ma) Is (ma) DIN M Metri-Pack 0 Input + A + Output C B % 00 % P (psi) 8 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

19 Selection and Specifi cations (continued) XMLK pressure transmitters, psi version With analog output 0 0 V Sizes 0 to 00 psi (0 to 0. ) transmitters type XMLK, PSI version, DIN 0A, M or Metri-Pack connector () DIN 0A connector M connector Metri-Pack connector range 0 00 psi (0. ) 0 0 psi (0 0. ) 0 00 psi (0.8 ) 0 00 psi (0 0. ) Selection transmitters XMLK, DIN 0A connector Sold in packs of: XMLK00PC XMLK0PC XMLK00PC XMLK00PC bulk () XMLK00PCTQ XMLK0PCTQ XMLK00PCTQ XMLK00PCTQ transmitters XMLK, M connector Sold in packs of: XMLK00PD XMLK0PD XMLK00PD XMLK00PD bulk () XMLK00PDTQ XMLK0PDTQ XMLK00PDTQ XMLK00PDTQ transmitters XMLK, Metri-Pack connector Sold in packs of: XMLK00PP XMLK0PP XMLK00PP XMLK00PP Fluid connection () bulk () XMLK00PPTQ XMLK0PPTQ XMLK00PPTQ XMLK00PPTQ /"-8 NPT male Weight, kg (lb) 0.0 (.) 0.0 (.) 0.0 (.) 0.0 (.) Additional specifications not shown under general specifications Rated supply voltage V c Voltage limits Output () Current consumption. V c 0 0 V, -wire technique < ma Maximum permissible accidental pressure 00 psi (.8 ) 00 psi (0. ) 00 psi (. ) 00 psi ( ) Destruction pressure 00 psi (0. ) 0 psi ( ) 00 psi ( ) 00 psi ( ) Electrical connection DIN 0A connector EN 0-80-A (male). For suitable female connector see accessories on page 0. M connector M, -pin male. For suitable female connectors, including pre-wired versions, see accessories on page 0. Metri-Pack connector -pin Delphi (Packard) Metri-Pack 0 series. () For other types of electrical connections, consult the Sensor Competency Center at () Sold in lots of, minimum quantity 0. () For other types of fl uid connections, consult the Sensor Competency Center at () For other types of output, consult the Sensor Competency Center at Output curve XMLKppPp Connector wiring: -wire technique (0 0 V) Us (V) % 00 % P (psi) DIN M Metri-Pack + Input + Output C + A B 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

20 Accessories and Wiring XMLK pressure transmitters For control circuits Connection accessories Description Type Reference Weight kg (lb) M female connector, metal clamping ring () Straight XZCCFDM0B 0.00 (0.0) Elbowed XZCCFCM0B 0.00 (0.0) XZ CCFDM0B XZ CCFCM0B DIN 0A female connector () XZCCFCP0B 0.0 (0.08) XZ CCFCP0B Description Pre-wired M, straight female connectors Pre-wired M, elbowed female connectors Cable Length Reference Weight kg (lb) m XZCPL 0.00 (0.0) m XZCPL 0.0 (0.) 0 m XZCPL0 0.0 (0.8) m XZCPL 0.00 (0.0) m XZCPL 0.0 (0.) 0 m XZCPL0 0.0 (0.8) XZ CPL0 XZ CPL () Connector with screw terminal connections. Connector wiring (pressure sensor connector pin view) transmitters XMLK -wire technique ( 0 ma) DIN M Metri-Pack Output Input + A + Output C B Input + -wire technique (0 0 V) DIN M Metri-Pack Input + + A Input + Output Output C B 0 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

21 Ø. Ø G / /-8 NPT Ø. Ø G / /-8 NPT Ø. Ø G / /-8 NPT Dimensions XMLK pressure transmitters For control circuits Dimensions XMLK, DIN connector NPT G / A (male) 8.8 SW. Ø 8.8 (± 0,) XMLK, M connector NPT G / A (male) SW. Ø 8.8 (± 0,) XMLK, Metri-Pack connector NPT G / A (male). Ø 8.8 (± 0,) Dimensions = mm / in. 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

22 Introduction Type XMLG For control circuits Introduction XMLG pressure transmitters and pressure switches are characterized by their ceramic pressure measuring cell. The deformation caused by the pressure is transmitted to the resistors of a Wheatstone bridge silk-screened on the ceramic. The change in resistance is then processed by the integrated electronics for providing either a digital or analog output signal. Electrical connection, for example: M Electronics with EMC protection Ceramic measuring cell Seals Leakage protection Threaded connection Functions transmitters have an analog 0 ma or 0 0 V output that is proportional to the measuring range. and vacuum switches have a solid-state NPN or PNP normally closed (NC) output. An anti-leakage system integrated in products for pressures u 0 prevents fl uid leakage in the event of the measuring cell destructive pressure being exceeded. These compact products that offer excellent EMC characteristics are particularly suited to diffi cult industrial environments. Important ordering requirement XMLG pressure and vacuum switches are factory set; the upper and lower switching thresholds must be specifi ed when ordering. Bulk packs are mainly intended for machine manufacturers. Interpretation of the Catalog Number XMLG XMLG 00 D TQ Units without display,.8 mm diameter Rated pressure Code psi M to 0 0 to. - to 0 0 to 00 0 to 8 0 to to 0 to 0 to 0 0 to to. 0 to 0 0 to 0 to to 0 to 00 0 to 0 0 to 00 Electrical connection D: M Q: Integrated quick connect Output Fluid connection Bulk pack : Analog, 0 ma : Solid state, NPN : Solid state, PNP : Analog, 0 0 V (bulk packs only) NOTE: Use this table only to interpret the catalog number. Some combinations are not available. : G / A (BSP male) : /" NPT male : /" NPTF female : /-0 UNF male 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

23 Specifi cations Type XMLG For control circuits Environmental specifications Conformity to standards Product certifications e IEC/EN 0-, IEC/EN 0-- EN 008-, EN 008-, EN UL, CSA Rated supply voltage Transmitters 0 ma / Vc /vacuum switches Transmitters 0 0 V Vc Voltage limits Transmitters 0 ma 8 Vc /vacuum switches Transmitters 0 0 V. Vc Current consumption /vacuum switches < ma Transmitters < 0 ma Protective treatment Standard version TC Ambient air temperature For operation to +8 C ( to 8 F) For storage 0 to +8 C ( 0 to 8 F) Fluids or products controlled Hydraulic oils, air, fresh water, sea water, corrosive fl uids from to + C ( to F) Component materials in contact with fluid Operating position Ceramic Al O, stainless steel type AISI 0, Viton FPM, PPS (Leakage protection for P > 0 ) All positions Vibration resistance 0 gn ( 000 Hz) conforming to IEC Shock resistance gn (half sine wave ms) conforming to IEC Resistance to electromagnetic interference Electrostatic discharges Radiated electromagnetic fi elds Fast transients Standard EN 000--, kv in air, 8 kv on contact Standard EN 000--, 00 V/m, MHz Standard EN 000--, kv Surges Standard EN 000--, 00 V Ω, kv Ω. Surges > 0 0 ms may damage the device. Electrical protection Conducted disturbances, Standard EN 000--, 0 V MHz induced by radio frequency fi elds Magnetic fi elds Standard EN , 0 A/m, 0 Hz Protected against reverse polarity and load short-circuit Rated impulse withstand voltage 0. kv Degree of protection IP, IP conforming to IEC/EN 0, NEMA Output response time Repeat accuracy < ms ± 0.% of the measuring range Precision Transmitters Combined sum of linearity, hysteresis, and repeat accuracy ± < 0.% of the measuring range Setting tolerance of zero point and measuring range limit ± < 0.% of the measuring range /vacuum switches Setting accuracy ± < % of the measuring range Drift Zero point ± < 0.0% of the measuring range/ C Sensitivity ± < 0.0% of the measuring range/ C Service life In millions of operating cycles > 0 Fluid connection /" NPT male conforming to ISO Electrical connection M connector or Phoenix Contact QUICKON type integrated connection. 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

24 Selection and Specifi cations XMLG pressure transmitters with analog output Sizes to (. to. psi) Units with analog output range () to 0 (. to 0 psi) 0 to (0 to. psi) Type of electrical connection () M Integrated quick connection M Integrated quick connection transmitters, 0 ma Sold in packs of: XMLGM0D XMLG00D bulk () XMLGM0DTQ XMLGM0QTQ XMLG00DTQ XMLG00QTQ transmitters, 0 0 V Sold in packs of: XMLGM0D XMLG00D bulk () XMLGM0DTQ XMLGM0QTQ XMLG00DTQ XMLG00QTQ Fluid connection () /" NPT male Weight, g (oz) (.) (.) (.) (.) Additional specifications not shown under general specifi cations (page ) Rated supply voltage / Vc Voltage limits 8 Vc Analog output 0 ma, -wire; or 0 0 V, -wire Current consumption < 0 ma Maximum permissible accidental pressure. (. psi). (. psi) Destructive pressure (. psi) (. psi) Electrical connection By connector XMLGpppDp: M, -pin male. For suitable female connectors, including pre-wired versions, see page Integrated XMLGpppQp: integrated connection, Phoenix Contact QUICKON type () For other pressure ranges, consult the Sensor Competency Center at () For other connections (such as AMP connector or cable), consult the Sensor Competency Center at () Sold in lots of, with a minimum order of 0 pcs. () For other fl uid connections (such as G / A BSP male or /" NPTF female), refer to Interpretation of the Catalog Number on page, or consult the Sensor Competency Center at Component materials of units in contact with the fl uid: see page. Output curves XMLGM0p Is (ma) 0 XMLG00p Is (ma) ,8-0, -0, -0, 0 P () 0 0, 0, 0, 0,8 P () 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

25 Selection and Specifi cations (continued) XMLG pressure transmitters with analog output Sizes 0 to ( to. psi) Units with analog output range () 0 0 (0 psi) 0 (0. psi) Type of electrical connection () M Integrated quick M Integrated quick connection connection transmitters, 0 ma Sold in packs of: XMLG00D XMLG0D bulk () XMLG00DTQ XMLG00QTQ XMLG0DTQ XMLG0QTQ transmitters, 0 0 V Sold in packs of: XMLG00D XMLG0D bulk () XMLG00DTQ XMLG00QTQ XMLG0DTQ XMLG0QTQ Fluid connection () /" NPT male Weight, g (oz) (.) (.) (.) (.) Additional specifications not shown under general specifi cations (page ) Rated supply voltage / Vc Voltage limits 8 Vc Analog output 0 ma, -wire; or 0 0 V, -wire Current consumption < 0 ma Maximum permissible accidental pressure ( psi) (8 psi) Destructive pressure (. psi). (0. psi) Electrical connection By connector XMLGpppDp: M, -pin male. For suitable female connectors, including pre-wired versions, see page Integrated XMLGpppQp: integrated connection, Phoenix Contact QUICKON type () For other pressure ranges, consult the Sensor Competency Center at () For other connections (such as AMP connector or cable), consult the Sensor Competency Center at () Sold in lots of, with a minimum order of 0 pcs. () For other fl uid connections (such as G / A BSP male or /" NPTF female), refer to Interpretation of the Catalog Number on page, or consult the Sensor Competency Center at Component materials of units in contact with the fl uid: see page. Output curves XMLG00p Is (ma) 0 XMLG0p Is (ma) P () P () 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

26 Selection and Specifi cations (continued) XMLG pressure transmitters with analog output Sizes 00 to 0 (0 to psi) Units with analog output range () 0 00 (0 0 psi) 0 0 (0 psi) Type of electrical connection () M Integrated quick M Integrated quick connection connection transmitters, 0 ma Sold in packs of: XMLG00D XMLG0D bulk () XMLG00DTQ XMLG00QTQ XMLG0DTQ XMLG0QTQ transmitters, 0 0 V Sold in packs of: XMLG00D XMLG0D bulk () XMLG00DTQ XMLG00QTQ XMLG0DTQ XMLG0QTQ Fluid connection () /" NPT male Weight, g (oz) (.) (.) (.) (.) Additional specifications not shown under general specifi cations (page ) Rated supply voltage / Vc Voltage limits 8 Vc Analog output 0 ma, -wire; or 0 0 V, -wire Current consumption < 0 ma Maximum permissible accidental pressure (. psi) 0 (80 psi) Destructive pressure 0 ( psi) (0. psi) Electrical connection By connector XMLGpppDp: M, -pin male. For suitable female connectors, including pre-wired versions, see page Integrated XMLGpppQp: integrated connection, Phoenix Contact QUICKON type () For other pressure ranges, consult the Sensor Competency Center at () For other connections (such as AMP connector or cable), consult the Sensor Competency Center at () Sold in lots of, with a minimum order of 0 pcs. () For other fl uid connections (such as G / A BSP male or /" NPTF female), refer to Interpretation of the Catalog Number on page, or consult the Sensor Competency Center at Component materials of units in contact with the fl uid: see page. Output curves XMLG00p Is (ma) 0 XMLG0p Is (ma) P () P () 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

27 Selection and Specifi cations (continued) XMLG pressure transmitters with analog output Size: 00 (800 psi) Units with analog output range () 0 00 (0 800 psi) Type of electrical connection () M Integrated quick connection transmitters, 0 ma Sold in packs of: XMLG00D bulk () XMLG00DTQ XMLG00QTQ transmitters, 0 0 V Sold in packs of: XMLG00D bulk () XMLG00DTQ XMLG00QTQ Fluid connection () /" NPT male Weight, g (oz) (.) (.) Additional specifications not shown under general specifi cations (page ) Rated supply voltage / Vc Voltage limits 8 Vc Analog output 0 ma, -wire; or 0 0 V, -wire Current consumption < 0 ma Maximum permissible accidental pressure 800 (,00 psi) Destructive pressure 00 (,00 psi) Electrical connection By connector XMLGpppDp: M, -pin male. For suitable female connectors, including pre-wired versions, see page Integrated XMLGpppQp: integrated connection, Phoenix Contact QUICKON type () For other pressure ranges, consult the Sensor Competency Center at () For other connections (such as AMP connector or cable), consult the Sensor Competency Center at Component materials of units in contact with the fl uid: see page. () Sold in lots of, with a minimum order of 0 pcs. () For other fl uid connections (such as G / A BSP male or /" NPTF female), refer to Interpretation of the Catalog Number on page, or consult the Sensor Competency Center at Component materials of units in contact with the fl uid: see page. Output curves XMLG00p Is (ma) P () 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

28 Selection and Specifi cations (continued) XMLG pressure and vacuum switches Sizes to (. to. psi) Units with solid-state output () Adjustable range of switching point (PH) () () Type of electrical connection () M Integrated quick connection Only sold in bulk packs () Fluid connection () 0.08 to (. to. psi) 0.08 to (. to. psi) M Integrated quick connection NPN output (N.C.) XMLGM0DTQ XMLGM0QTQ XMLG00DTQ XMLG00QTQ PNP output (N.C.) XMLGM0DTQ XMLGM0QTQ XMLG00DTQ XMLG00QTQ /" NPT male Weight, g (oz) (.) (.) (.) (.) Additional specifications not shown under general specifi cations (page ) Switching thresholds () Factory set Possible differential Min. at low setting 0.0 (0. psi) 0.0 (0. psi) Min. at high setting 0.0 (0. psi) 0.0 (0. psi) Max. at high setting 0. (. psi) 0. (. psi) Maximum permissible accidental pressure. (. psi). (. psi) Destructive pressure (. psi) (. psi) Rated supply voltage / Vc Voltage limits 8 Vc Output Solid-state, NPN or PNP, NC Switching capacity 0 ma Current consumption < ma Electrical connection By connector XMLGpppDp: M, -pin male. For suitable female connectors, including pre-wired versions, see page Integrated XMLGpppQp: integrated connection, Phoenix Contact QUICKON type () For other types of output (such as normally open PNP or NPN), consult the Sensor Competency Center at () For other pressure ranges, consult the Sensor Competency Center at () For other connections (such as cable and AMP connector), consult the Sensor Competency Center at () Sold in lots of, with a minimum order of 0 pcs. () For other fl uid connections (such as G / A BSP male or /" NPTF female), refer to Interpretation of the Catalog Number on page, or consult the Sensor Competency Center at Component materials of units in contact with the fl uid: see page. () Must state the switching threshold settings when ordering. () For vacuum switches (size ): adjustable range of switching point (PB) on falling pressure. Operating curves XMLGM0pp XMLG00pp -0, -0, -0,0 0-0,08-0, 0, 0 Maximum differential Minimum differential - Falling pressure 0,08 0 0,0 0, 0, Falling pressure 8 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

29 Selection and Specifi cations (continued) XMLG pressure switches Sizes 0 to (. to. psi) Units with solid-state output () Adjustable range of switching point (PH) () Type of electrical connection () M Integrated quick connection Only sold in bulk packs () Fluid connection () (. psi) (. psi) M Integrated quick connection NPN output (N.C.) XMLG00DTQ XMLG00QTQ XMLG0DTQ XMLG0QTQ PNP output (N.C.) XMLG00DTQ XMLG00QTQ XMLG0DTQ XMLG0QTQ /" NPT male Weight, g (oz) (.) (.) (.) (.) Additional specifications not shown under general specifi cations (page ) Switching thresholds () Factory set Possible differential Min. at low setting 0. (. psi) 0. (0. psi) Min. at high setting 0. (. psi) 0. (0. psi) Max. at high setting. (. psi).8 (. psi) Maximum permissible accidental pressure ( psi) (8 psi) Destructive pressure (. psi). (0. psi) Rated supply voltage / Vc Voltage limits 8 Vc Output Solid-state, NPN or PNP, NC Switching capacity 0 ma Current consumption < ma Electrical connection By connector XMLGpppDp: M, -pin male. For suitable female connectors, including pre-wired versions, see page Integrated XMLGpppQp: integrated connection, Phoenix Contact QUICKON type () For other types of output (such as normally open PNP or NPN), consult the Sensor Competency Center at () For other pressure ranges, consult the Sensor Competency Center at () For other connections (such as AMP connector or cable), consult the Sensor Competency Center at () Sold in lots of, with a minimum order of 0 pcs. () For other fl uid connections (such as G / A BSP male or /" NPTF female), refer to Interpretation of the Catalog Number on page, or consult the Sensor Competency Center at Component materials of units in contact with the fl uid: see page. () Must state the switching threshold settings when ordering. Operating curves XMLG00pp XMLG0pp Maximum differential Minimum differential 0, ,, Falling pressure 0, 0 0, Falling pressure Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

30 Selection and Specifi cations (continued) XMLG pressure switches Sizes 00 to 0 (0 to psi) Units with solid-state output () Adjustable range of switching point (PH) () Type of electrical connection () M Integrated quick connection Only sold in bulk packs () Fluid connection () 8 00 (. 0 psi) 0 0 ( psi) M Integrated quick connection NPN output (N.C.) XMLG00DTQ XMLG00QTQ XMLG0DTQ XMLG0QTQ PNP output (N.C.) XMLG00DTQ XMLG00QTQ XMLG0DTQ XMLG0QTQ /" NPT male Weight, g (oz) (.) (.) (.) (.) Additional specifications not shown under general specifi cations (page ) Switching thresholds () Factory set Possible differential Min. at low setting (. psi). (08.8 psi) Min. at high setting (. psi). (08.8 psi) Max. at high setting (. psi). (. psi) Maximum permissible accidental pressure (. psi) 0 (80 psi) Destructive pressure 0 ( psi) (0. psi) Rated supply voltage / Vc Voltage limits 8 Vc Output Solid-state, NPN or PNP, NC Switching capacity 0 ma Current consumption < ma Electrical connection By connector XMLGpppDp: M, -pin male. For suitable female connectors, including pre-wired versions, see page Integrated XMLGpppQp: integrated connection, Phoenix Contact QUICKON type () For other types of output (such as normally open PNP or NPN), consult the Sensor Competency Center at () For other pressure ranges, consult the Sensor Competency Center at () For other connections (such as AMP connector or cable), consult the Sensor Competency Center at () Sold in lots of, with a minimum order of 0 pcs. () For other fl uid connections (such as G / A BSP male or /" NPTF female), refer to Interpretation of the Catalog Number on page, or consult the Sensor Competency Center at Component materials of units in contact with the fl uid: see page. () Must state the switching threshold settings when ordering. Operating curves XMLG00ppTQ XMLG0ppTQ Maximum differential Minimum differential Falling pressure 0 0, 00 00, Falling pressure 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

31 Selection and Specifi cations (continued) Type XMLG pressure switches Size: 00 (800 psi) Units with solid-state output () Adjustable range of switching point (PH) 00 ( 800 psi) () Type of electrical connection () M Integrated quick connection Only sold in bulk packs () Fluid connection () NPN output (N.C.) XMLG00DTQ XMLG00QTQ PNP output (N.C.) XMLG00DTQ XMLG00QTQ /" NPT male Weight, g (oz) (.) (.) Additional specifications not shown under general specifi cations (page ) Switching thresholds () Factory set Possible differential Min. at low setting ( psi) Min. at high setting ( psi) Max. at high setting 80 (0 psi) Maximum permissible accidental pressure 800 (,00 psi) Destructive pressure 00 (,00 psi) Rated supply voltage / Vc Voltage limits 8 Vc Output Solid-state, NPN or PNP, NC Switching capacity 0 ma Current consumption < ma Electrical connection By connector XMLGpppDp: M, -pin male. For suitable female connectors, including pre-wired versions, see page Integrated XMLGpppQp: integrated connection, Phoenix Contact QUICKON type () For other types of output (such as normally open PNP or NPN), consult the Sensor Competency Center at () For other pressure ranges, consult the Sensor Competency Center at () For other connections (such as AMP connector or cable), consult the Sensor Competency Center at () Sold in lots of, with a minimum order of 0 pcs. () For other fl uid connections (such as G / A BSP male or /" NPTF female), refer to Interpretation of the Catalog Number on page, or consult the Sensor Competency Center at Component materials of units in contact with the fl uid: see page. () Must state the switching threshold settings when ordering. Operating curve XMLG00ppTQ Maximum differential Minimum differential Falling pressure 0 Courtesy of Steven Engineering, Inc. - (800) sales@steveneng.com -

Electronic pressure sensors

Electronic pressure sensors Presentation, type XML P For control circuits Presentation Pressure transmitters XML P are characterised by their thin fi lm technology. The stainless steel pressure sensing capsule is directly welded

More information

Pressure transmitters OsiSense XMLP for industrial applications. Catalogue

Pressure transmitters OsiSense XMLP for industrial applications. Catalogue Pressure transmitters OsiSense XMLP for industrial applications Catalogue A compact and optimised product for industrial applications The new OsiSense XMLP pressure transmitters are for regulating fluid

More information

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1 Characteristics pressure sensor XMLK - 0..6bar - G 1/4A - 4..20mA - DIN - set of 1 Complementary Pressure setting range Maximum permissible accidental pressure Destruction pressure Materials in contact

More information

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12 Characteristics Pressure sensors XMLR 400bar - G 1/4-24VDC - 4..20 ma - PNP - M12 Complementary Current consumption Electrical connection Type of output signal Analogue output function Discrete output

More information

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/4"18NPT V - M12 - set 1

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/418NPT V - M12 - set 1 Characteristics pressure transmitter - XMLP - 200psi - 1/4"18NPT - 0..10V - M12 - set 1 Complementary Pressure setting range Maximum permissible accidental pressure Destruction pressure Materials in contact

More information

Electromechanical pressure switches

Electromechanical pressure switches Presentation Presentation Pressure type XMX and XMA are for control circuits, with an adjustable differential. They are used to control the pressure of water and air, up to. Equipment fitted to the various

More information

Electromechanical pressure switches

Electromechanical pressure switches Presentation Electromechanical pressure switches For control circuits, types ACW and ADW Presentation Pressure switches type ACW and ADW are switches for control circuits, with an adjustable differential.

More information

Electronic pressure switch with display Model PSD-4

Electronic pressure switch with display Model PSD-4 Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine

More information

M7100 Pressure Transducer

M7100 Pressure Transducer Pressure Transducer Performance standard to on and off highway engines and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless Steel wetted

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

M5100 Heavy Industrial Pressure Transducer

M5100 Heavy Industrial Pressure Transducer CE Compliance Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations DESCRIPTION The M5100 series pressure transducers from the Microfused line of MEAS, set a new price

More information

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550 Data sheet Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550 The P500 / P507 / P550 utilizes the thin film strain gauge sensing technology, incorporating an hermetically

More information

U7100 Pressure Transducer

U7100 Pressure Transducer Performance standard for on and off highway engine & vehicle OEMs Rugged for heavy equipment and outdoor use such as HVAC refrigeration systems Designed specifically for high volume applications Stainless

More information

Temperature Switches

Temperature Switches ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,

More information

OEM Products for Large Volume Production:

OEM Products for Large Volume Production: OEM Products OEM Products for Large Volume Production Areas of application for our OEM products for large volume production range from mobile and stationary industrial hydraulics, to pneumatics, machine

More information

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm Electronic pressure measurement Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm WIKA data sheet PE 81.25 for further approvals see page 5 MicroTronic

More information

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application P30-2 Pressure Transmitter Datasheet At a Glance *High Quality* 3 Years Warranty Premium Pressure Transmitter for gauge and pressure measurement with 3 years warranty High repeatability and long-term stability

More information

02/11/2015

02/11/2015 35 mm - 1 Relay 8A OUR1 Part number 88867105 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits sales@jumo.co.uk info.us@jumo.net Page /0 JUMO MIDAS C08 OEM Pressure Transmitter Basic Applications compressors machinery and plant engineering industrial pneumatics commercial vehicles building technology

More information

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/ DC - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type Time

More information

TM3AI4 module TM3-4 analog inputs

TM3AI4 module TM3-4 analog inputs Characteristics module TM3-4 analog inputs Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible

More information

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits Data Sheet 4000 Page /0 JUMO MIDAS C08 OEM Pressure Transmitter Basic Applications compressors machinery and plant engineering industrial pneumatics commercial vehicles building technology Brief description

More information

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output Characteristics off-delay timing relay - control - 1 s..100 h - 24..240 V - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type

More information

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main. Characteristics green complete illuminated selector switch Ø22 2- position stay put 1NO+1NC 24V Main Range of product Product or component type Device short name Bezel material Fixing collar material Mounting

More information

Limit switches 3. with solenoid interlocking. Metal, type XCSE and XCSL. Page 6/284. Page 6/296

Limit switches 3. with solenoid interlocking. Metal, type XCSE and XCSL. Page 6/284. Page 6/296 ntroduction, Specifi cations Limit switches with solenoid interlocking etal, type CSE and CSL Plastic, double insulated, type CSTE etal, type CSE and CSL Safety interlock switches with locking of the actuator

More information

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/DC - solid state output Complementary Control type Voltage range Main Range of product Product or component type Discrete output type Width

More information

TM3DI16 module TM3-16 inputs

TM3DI16 module TM3-16 inputs Characteristics module TM3-16 inputs Main Range of product Product or component type Range compatibility Jun 30, 2018 Modicon TM3 Discrete input module Modicon M241 Modicon M251 Modicon M221 Discrete input

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector Characteristics expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus type [Ue] rated operational

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

TM3TI4 module TM3-4 inputs temperature

TM3TI4 module TM3-4 inputs temperature Characteristics module TM3-4 inputs temperature Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible

More information

Inductive Cylinder Position Sensors

Inductive Cylinder Position Sensors Inductive Cylinder Position Sensors 4-Wire DC (NPN and PNP) 2-Wire AC/DC Weld immune 250, 000, and 3000 psi designs C-Series F-Series Rating (psi) Probe Diameter Inductive Cylinder Position Sensors Pepperl+Fuchs

More information

XB4BW33B5 green flush complete illum pushbutton Ø22 spring return 1NO+1NC 24V

XB4BW33B5 green flush complete illum pushbutton Ø22 spring return 1NO+1NC 24V Characteristics green flush complete illum pushbutton Ø22 spring return 1NO+1NC 24V Product availability : Stock - Normally stocked in distribution facility Price* : 119.00 USD Main Range of product Product

More information

TM3TI8T module TM3-8 inputs temperature

TM3TI8T module TM3-8 inputs temperature Characteristics module TM3-8 inputs temperature Main Range of product Product or component type Range compatibility Analogue input number 8 Analogue input type Complementary Analogue input resolution Input

More information

TM3SAF. Main. Device short name

TM3SAF. Main. Device short name Product datasheet Characteristics TM3SAF5R SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT4, SCREW TERMINALS Complementary Main Range of product Product or component type Device short name Safety module application

More information

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 300 Electronic Pressure Switch EDS 300 Description: The EDS 300 is a compact, electronic pressure switch with integral digital display. Four different output models are available: with one switching point,

More information

HIGH ACCURACY PRESSURE TRANSDUCERS

HIGH ACCURACY PRESSURE TRANSDUCERS HIGH ACCURACY PRESSURE TRANSDUCERS PX409-100GV, RUGGEDIZED DESIGN For Aerospace, Automotive, Test and Industrial Applications U 0.08% BSL Includes Linearity Hysteresis and Repeatablity U Broad Temperature

More information

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 Electronic pressure measurement Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 WIKA data sheet PE 81.53 Applications Test bench construction Water jet

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Pressure Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics and pneumatics Pumps and

More information

RM4JA01F current measurement relay RM4-J - range ma V AC

RM4JA01F current measurement relay RM4-J - range ma V AC Characteristics current measurement relay RM4-J - range 3..1000 ma - 110..130 V AC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Power consumption in

More information

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O Characteristics Off-delay Timing Relay - 0.05s 10min - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts

More information

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O Characteristics Star-Delta Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts

More information

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RM35JA32MR Current control relay 0.15A 15A, 2 C/O Characteristics Current control relay 0.15A 15A, 2 C/O Main Range of product Product or component type Relay type Relay name Relay monitored parameters Time delay type Switching capacity in VA Measurement

More information

RM4TA32 three-phase network control relay RM4-T - range V

RM4TA32 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 380..500 V Complementary [Us] rated supply voltage Output contacts Main Range of product Product or component type Relay type Product specific

More information

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TM3TM3 module TM3-2 temperature inputs and 1 analog output Characteristics module TM3-2 temperature inputs and 1 analog output Main Range of product Product or component type Range compatibility Analogue input number 2 Analogue input type Analogue output number

More information

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12 Characteristics CANopen interface block - IP67-16 I/O - M12 Main Range of product Product or component type Range compatibility Enclosure material Bus type [Ue] rated operational voltage Input/Output number

More information

02/11/2015

02/11/2015 DIN Rail Mount 22.5 mm TU2R1 Part number 88865305 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /

More information

Push Buttons and Operator Interface New Product Catalog XAL Control Stations

Push Buttons and Operator Interface New Product Catalog XAL Control Stations Push Buttons and Operator Interface New Product Catalog XAL Control Stations CONTENTS Description.................................................... Page General Information................................................104

More information

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS Characteristics SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS Main Range of product Product or component type Device short name Safety module application Function of module Jun 29, 2018

More information

TM3TI4 module TM3-4 inputs temperature

TM3TI4 module TM3-4 inputs temperature Characteristics module TM3-4 inputs temperature Complementary Analogue input resolution Permissible continuous overload Input impedance LSB value Conversion time Sampling duration Main Range of product

More information

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O Characteristics star-delta timing relay - 230VAC/440VAC - 1 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts type

More information

Electronic Level Switch ENS 3000

Electronic Level Switch ENS 3000 Electronic Level Switch ENS 3000 Description: The ENS 3000 is an electronic level switch with integrated display. The instrument has 1, 2 or 4 switching outputs and an analogue output signal is available

More information

XGCS491B201 Standalone panel smart antenna

XGCS491B201 Standalone panel smart antenna Characteristics Standalone panel smart antenna Complementary Operating mode Type of output signal Discrete output function Discrete output type Switching capacity in ma Associated tag type Supply voltage

More information

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O Characteristics On-delay Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts

More information

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O Characteristics Off-delay Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts

More information

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts Data sheet Electronic timer CT-SDD. Star-delta change-over with n/o contacts The CT-SDD. is an electronic time relay with star-delta change-over. It is from the CT-D range. With their MDRC profile and

More information

XCKN2110P20 limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20

XCKN2110P20 limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20 Characteristics limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 20.80 USD Main Range of product OsiSense

More information

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

08/07/2015

08/07/2015 DIN Rail Mount 22.5 mm TUR1 Part number 88865105 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /

More information

Zelio Count - Counters RC87610

Zelio Count - Counters RC87610 Zelio Count - Counters RC87610 Catalog March 05 Class 9051 CONTENTS Description..............................................Page Product Description........................................... RC87610050

More information

Operating instructions Electronic pressure sensor. PM205x /01 09/2011

Operating instructions Electronic pressure sensor. PM205x /01 09/2011 Operating instructions Electronic pressure sensor PM205x 706071/01 09/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4

More information

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

XB7NA4234 PB - Spring Rtn, red - 1NC -White STOP Characteristics PB - Spring Rtn, red - 1NC -White "STOP" Main Range of product Product or component type Device short name Mounting diameter Sep 4, 2018 Harmony XB7 Push-button XB7 Sale per indivisible

More information

XXA18P1AM12 Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12

XXA18P1AM12 Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12 Characteristics Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12 Complementary Enclosure material Front material Supply voltage limits Function available [Sa] assured operating

More information

TM3DI16G module TM3-16 inputs spring

TM3DI16G module TM3-16 inputs spring Characteristics module TM3-16 inputs spring Main Range of product Product or component type Range compatibility Modicon TM3 Discrete input module Modicon M221 Modicon M241 Modicon M251 Discrete input number

More information

TM3SAK. Main. Device short name

TM3SAK. Main. Device short name Product datasheet Characteristics TM3SAK6R SAFETY MODULE FOR PLC TM2xx, 3 FUNCTIONS, CAT4, SCREW TERMINALS Complementary Main Range of product Product or component type Device short name Safety module

More information

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector Characteristics expansion block - TM7 - IP67-16 DI/DO - 24V DC - 0.5 A - M12 connector Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 753.00 USD Main Range of

More information

52 x 72 x 30 (2.05 x 2.83 x 1.18) N/C + N/O; N/C + N/C N/C + N/O N/C + N/O; N/C + N/C

52 x 72 x 30 (2.05 x 2.83 x 1.18) N/C + N/O; N/C + N/C N/C + N/O N/C + N/O; N/C + N/C Selection Guide Osiswitch Classic Design Classic Catalog number XCKM XCKL XCKJ Enclosure Metal Fixed or plug-in body, -4 C (-4 F) Features 3 conduit entries or +2 C (+248 F) versions Modularity Head +

More information

DATASHEET. Ultra Capacitor Charger, UCC-4

DATASHEET. Ultra Capacitor Charger, UCC-4 DATASHEET Ultra Capacitor Charger, UCC-4 Easy installation Monitoring and surveillance of operation Balancing to save energy 90-450 V DC 3.5A Output Modular Ultra Capacitor system Document no.: 4921260003

More information

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure

More information

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO Characteristics compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO Main Range of product Product or component type Complementary Enclosure material Colour Input/Output number

More information

Electronic timer CT-ERS.21

Electronic timer CT-ERS.21 2CDC 251 057 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function ON delay timer One device includes 10 time ranges (0.05 s 300 h) 2 c/o contacts 2 LEDs for status indication Width

More information

RM4JA32MW current measurement relay RM4-J - range A V AC DC

RM4JA32MW current measurement relay RM4-J - range A V AC DC Characteristics current measurement relay RM4-J - range 0.3..15 A - 24..240 V AC DC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Power consumption in

More information

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Characteristics Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Main Range of product Product or component type Complementary Supply [Us] rated supply voltage Immunity to microbreaks

More information

RM4TR31 three-phase network control relay RM4-T - range V

RM4TR31 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 160..220 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range

More information

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Level sensor Stainless steel version Model RLT-1000, for industrial applications Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring

More information

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2 Pressure Pressure sensor For highest pressure applications to 15,000 bar Model HP-2 WIKA data sheet PE 81.53 for further approvals see page 6 Applications Test bench construction Water jet cutting High-pressure

More information

TM221CE40T controller M IO transistor PNP Ethernet

TM221CE40T controller M IO transistor PNP Ethernet Product data sheet Characteristics TM221CE40T controller M221 40 IO transistor PNP Ethernet Complementary Main Discrete I/O number 40 Number of I/O expansion module Supply voltage limits Inrush current

More information

Electronic timer CT-AHD.22

Electronic timer CT-AHD.22 2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC Characteristics off-delay timing relay with control contact - 0.05..1 s - 24 V AC DC - 1OC Main Range of product Product or component type Component name Time delay type Time delay range [Us] rated supply

More information

em4 Accessories Digital expansions

em4 Accessories Digital expansions em4 Accessories Digital expansions Up to two digital / analog expansions can be added to the em4 nanoplc to expand up to 46 I/Os 6 digital / analog configurable inputs (0-10 VDC, 0-28.8 VDC, Potentiometer)

More information

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free

More information

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box Product datasheet Characteristics TM7BDM8B Main Range of product Product or component type Range compatibility Enclosure material Bus type System Voltage Input/output number 8 Input/output number of splitter

More information

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O Characteristics star-delta timing relay - 230VAC/440VAC - 1 C/ O Main Range of product Product or component type Discrete output type Device short name Nominal output current Zelio Time Modular timing

More information

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet 2CDC 251 056 F0t07 Features Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function ON-delay timer One device includes 10 time ranges (0.05 s - 300 h) 1 c/o contact 2 LEDs for status indication

More information

Pressure Transmitter type 548 with display and programmable switching outputs

Pressure Transmitter type 548 with display and programmable switching outputs Pressure Transmitter type 548 with display and programmable switching outputs Pressure range... 0 40 bar The øpregulated, programmable pressure transmitter type 548 has a robust industry design. The parameters

More information

Electronic timer CT-ARS.11

Electronic timer CT-ARS.11 2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact

More information

DM28 - Economical Digital Process and Strain Gauge Panel Meters

DM28 - Economical Digital Process and Strain Gauge Panel Meters DM28 - Economical Digital Process and Strain Gauge Panel Meters TRANSDUCERS Easily scaled in any engineering units from -19999 to 99999 Large 18mm (.71 ) high red or green display Front panel MIN, MAX

More information

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

Flow measurement FlexFlow PF20S Flow sensor for industrial applications Product highlights Parallel measurement of flow and temperature Flow measurement independent of the mounting position Large measuring range up to 400 cm/s Measurement at high media temperatures up to 125

More information

Electronic timer CT-ERD.12

Electronic timer CT-ERD.12 2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact Data sheet Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact The CT-EBD.12 is an electronic time relay with the function flasher starting with ON. It is from the CT-D range.

More information

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor DCT 5 Industrial Pressure Transmitter with RS85 Modbus RTU Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar output

More information

Digital Indicator Solutions

Digital Indicator Solutions Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display

More information

Installation Instructions Temperature transmitter TAA /00 06/2011

Installation Instructions Temperature transmitter TAA /00 06/2011 Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to

More information

Inductive proximity switches with long operating distance, series 500

Inductive proximity switches with long operating distance, series 500 Inductive proximity switches with long operating distance, series 500 Highlights World's longest operating distances on steel Sizes Ø 4... M30 embeddable (Ø 4 and M5), (... M30) and non-embeddable (M...

More information

TPE 1464 Series Pressure Transducer

TPE 1464 Series Pressure Transducer TPE 1464 Series Pressure Transducer Description The KMC TPE 1464 series of pressure transducers incorporate a gauge pressure transmitter featuring low hysteresis, excellent repeatability, and longterm

More information

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC Characteristics Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC Main Range of product Product or component type Device short name Mounting diameter Sep 4, 2018 Harmony XB7 Emergency

More information

TF501, TF521 Terminal Bases

TF501, TF521 Terminal Bases Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter NAT 8 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The industrial transmitter

More information

XGCS850C201 RFID compact smart antenna MHz- Ethernet dual port communication

XGCS850C201 RFID compact smart antenna MHz- Ethernet dual port communication Characteristics RFID compact smart antenna 13.56 MHz- Ethernet dual port communication Main Range of product Product or component type RFID compact station name RFID frequency OsiSense XG Compact smart

More information

TM221M32TK controller M IO transistor PNP

TM221M32TK controller M IO transistor PNP Characteristics controller M221 32 IO transistor PNP Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type Discrete

More information