GETTING STARTED WITH IN-WALL RELAY SWITCH

Size: px
Start display at page:

Download "GETTING STARTED WITH IN-WALL RELAY SWITCH"

Transcription

1 GETTING STARTED WITH IN-WALL RELAY SWITCH This document is the property of Webee L.L.C. The data contained here, in whole or in part, may not be duplicated, used or disclosed outside the recipient for any purpose. This restriction does not limit the recipient's right to use information contained in the data if it is obtained from another source without restriction. 1

2 INDEX Section 1: Mounting your In-Wall Relay Switch Installation...03 In-Wall Relay Switch Connection Diagram...04 Other connection styles Diagrams...05 Section 2: Connecting to Smartee Adding In-Wall Relay Switch to Zigbee Network...06 Binding In-Wall Relay Switch...06 Section 3: Specs Specifications...07 Dimensions...08 Section 4: Security Instructions Security Guidelines...09 Page 02

3 1 1 MOUNTING YOUR IN-WALL RELAY SWITCH Instructions Warnings! To reduce the risk of serious injury or death, turn power OFF before installing this product. (Ce produit doit être à la terre conformément à NEC et exigences locales.) This device must be installed by competent licensed electricians. (Cet appareil doit être installé par un électricien compétent autorisé.) This product must be grounded in accordance to NEC and Local requirements. (Ce produit doit être à la terre conformément à NEC et exigences lo-cales.) Caution! Using this product in any manner other than outlined in this document voids your warranty. Webee is not responsible for any damage incurred as a result of misuse or abuse of this product. (L'utilisation de ce produit de quelque autre manière que décrites dans le présent document annule votre garantie. Webee n'est pas responsable de tout dommage subi à la suite d'un détournement ou d'abus de ce produit.) Installation 1. Confirm that the intended installation location conforms to the following requirements: -Wall box must meet box size requirements specified by the NEC (National Electric Code.) -Installation will be completed according to national and local codes. -The load being controlled by the device does not exceed 1000 W. 2. To avoid SERIOUS INJURY or DEATH, turn OFF the local electrical power feeding the switch location. To disconnect power, turn off the breaker or remove the fuse from the fuse box. Verify that there is no power present using a voltage meter or test light. 3. If you are replacing an existing switch, note which wires are the Ground, Circuit Feed (HOT), Load (Switch Leg), and Neutral, when removing the existing switch. 4. Prepare the wires for connection by stripping off the insulation 5/8 of an inch. 5. Connect the ZigBee HA Relay Switch Wires using the supplied wire nuts. Connect GREEN wire from switch to GROUND Connect BLACK wire from switch to HOT FEED Connect WHITE wire from switch to NEUTRAL Connect RED wire from switch to LOAD Page 03

4 Warnings! If a direct short is created between the RED wire and GROUND or NEUTRAL, the Relay Switch will be damaged and unusable. (Si un court direct est créé entre le fil rouge et SOL ou neutre, le commutateur de relais sera endommagée et inutilisable.) 6. Test all connections. Fold wires and push them neatly into the switch box. Align the Relay Switch in the switch box with the air gap switch oriented at the bottom of the Relay Switch. Using the supplied screws, secure the Relay Switch in the switch box. 7. Verify that the Air Gap switch is fully pushed in. Then turn ON circuit breaker or replace the fuse. 8. If the Relay Switch is installed properly the top LED will blink slowly for 100 seconds signifying that the device is working as a independent local device. 9. You should now be able to control the load by tapping the top button. In-Wall Relay Switch Connection Diagram Connect GREEN wire from switch to GROUND Connect BLACK wire from switch to HOT FEED Connect WHITE wire from switch to NEUTRAL Connect RED wire from switch to LOAD For Keypad Function (Below): Cap RED wire on switch, do not connect. Page 04

5 Other connection styles Wiring for 3-way with load at the end of the circuit. Wiring for 3-way with load in the middle of the circuit. Wiring for 3-way with load at beginning of the circuit. Page 05

6 2 1 CONNECTING TO SMARTEE Adding to Zigbee Network To join the In-Wall Relay Switch to the Smartee, follow these instructions: 1- Click on the Add Device on your App. 2-If the LED on the switch is blinking (scanning for a network to join) and the switch is within range of Smartee ZigBee HA network it will join the network. 3. If the LED is not blinking, press and hold the top button for two seconds. The LED should start blinking and scanning for a network to join. If the Relay Switch has not been captured onto a ZigBee HA network, it s LED will blink slowly upon power up for 100 seconds. Once it s top button is pressed the LED will indicate the Relay Switch Load ON/OFF status. If the load is connected properly the light should toggle states with every button tap. If after following these steps the In-Wall Relay Switch will not join the Smartee Zigbee network, factory default your switch and try again. To factory default your switch do as follows: 1. Disconnect power by pulling out the airgap switch. 2. While pushing the top button, power the switch on by pushing in the airgap switch. 3. After 2 seconds the status LED will turn ON. 4. Once the status LED is ON, release the button. Verify that the switch is wired correctly and powered up. The LED's should light up on the face plate. Button controlling Load: -Tap the button to turn the light ON/OFF. Binding Instructions One *Load Device can have multiple *Keypads bound to it. In order to bind a keypad to a load please follow the following steps: 1. Locate the Load Device and quickly tap the button 6 times, and on the 6th tap push and hold the button down for one second. The LED should start fast blinking. 2. Once the Led is fast blinking, tap the button once. 3. You now have one minute to locate the Keypad you wish to bind to the Load. 4. Once located, quickly tap the button 6 times, and on the 6th tap push and hold the button down for one second. The LED should start fast blinking. 5. Once the LED is fast blinking briefly push and hold the button. To test if this is working, tap the button on the Keypap device and it should toggle the Load. To bind another keypad to the Load, repeat steps 1-5 for the other Keypad with the same Load. To unbind a keypad from the Load, repeat steps 1-5 for the Keypad you wish to unbind. *Load Device = Device that is actually connected to the light via the Red Wire. *Keypad = Device that only has power and neutral and the red wire is capped off. Page 06

7 323 1 IN-WALL RELAY SWITCH SPECS Electrical specifications Description Min Typ Max Unit Rated VAC Input frequency Hz Operating temperature -20º - 40º ºC Storage temperature -20º - 50º ºC Operating Humidity 0-90% RH (nonconndensing) Supported Loads -120 VAC 1/2 HP Motor -120 VAC 1000 W Halogen -120 VAC 1000 W Fluorescent -120 VAC 1000 VA Magnetic Low Voltage Transformer -120 VAC 1000 VA Electronic Low Voltage Transformer VAC Wireless RF Characteristics Description Min Typ Max Unit RF Channels TX Strength dbm Range - >100 ft. (>30m) ft. Protocol Zigbee HA 1.2 Page 07

8 Dimensions Page 08

9 4 1 SAFETY INSTRUCTIONS Safety Guidelines -To be installed and/or used in accordance with appropriate electrical codes and regulations. -If you are unsure about any of these instructions, consult a qualified electrician. -Follow all guidelines carefully, if you have any questions contact us at support@webeelife.com. Warning: Make sure to veriffy that the devices you are connecting are within the electrical range of the In-Wall Relay Switch. Otherwise, it will be damage and will no longer function. Page 09

10 V1.0 REV. February, Webee LLC, All rights reserved. The Webee logo, Smartee and Bees are trademarks or registered trademarks of Webee LLC 10

GETTING STARTED WITH SMART PLUG

GETTING STARTED WITH SMART PLUG 2 GETTING STARTED WITH SMART PLUG This document is the property of Webeee L.L.C.. The data contained here, in whole or in part, may not be duplicated, used or disclosed outside the recipient for any purpose.

More information

GETTING STARTED WITH SWITCHEE

GETTING STARTED WITH SWITCHEE GETTING STARTED WITH SWITCHEE This document is the property of Webee L.L.C. The data contained here, in whole or in part, may not be duplicated, used or disclosed outside the recipient for any purpose.

More information

GETTING STARTED WITH SWITCHEE

GETTING STARTED WITH SWITCHEE GETTING STARTED WITH SWITCHEE This document is the property of Webee Corporation. The data contained here, in whole or in part, may not be duplicated, used or disclosed outside the recipient for any purpose.

More information

Installation Instructions

Installation Instructions Please read all instructions before installing SPECIFICATIONS RT-100 Time Switch Programmable Countdown Voltage...120VAC, 60HZ Load (Single Pole Circuit) Incandescent or fluorescent lamp... 0 600 Watt

More information

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2 RF Home Automation ZRF113 Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2 Note: This module must be Included in the Network only where it will

More information

Installation Instructions

Installation Instructions Please read all instructions before installing RS-350 PIR Dual Relay Universal Application Wall Switch Vacancy Sensor with Manual ON/OFF Lens Lighted Switch ON/OFF button for Relay 1 ON/OFF button for

More information

INSTALLATION & SETUP GUIDE FOR SINGLE POLE & 3-WAY CONFIGURATIONS IN WALL SOLUTIONS

INSTALLATION & SETUP GUIDE FOR SINGLE POLE & 3-WAY CONFIGURATIONS IN WALL SOLUTIONS INSTALLATION & SETUP GUIDE FOR SINGLE POLE & 3-WAY CONFIGURATIONS IN WALL SOLUTIONS 1 REQUIRES Wi-Fi 2.4 GHz 802.11 b/g/n compatible network Router Security Settings Supported: WPA, WPA2, or None Free

More information

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English Configurable Output Distribution 120V / 208V / 240V 60Hz User Manual English TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................... 1 GLOSSARY OF SYMBOLS....................................

More information

INSTALLATION AND SETUP GUIDE

INSTALLATION AND SETUP GUIDE INSTALLATION AND SETUP GUIDE idevices SMART HOME SOLUTIONS 1 REQUIRES A compatible idevices product idevices Connected app Controlling this product requires an iphone, ipad or ipod touch that supports

More information

DEAKO SWITCH INSTALLATION GUIDE. Includes instructions for single-pole, 3-way, 4-way and dead-end 3-way wiring configurations for Deako Switches.

DEAKO SWITCH INSTALLATION GUIDE. Includes instructions for single-pole, 3-way, 4-way and dead-end 3-way wiring configurations for Deako Switches. DEAKO SWITCH INSTALLATION GUIDE Includes instructions for single-pole, -way, 4-way and dead-end -way wiring configurations for Deako Switches. DEAKO.COM BEFORE YOU GET STARTED This installation guide is

More information

Z-Wave Certified Wireless Lighting Control. Auxiliary Switch ZW2001 ZW2002 rev. 09/01/11

Z-Wave Certified Wireless Lighting Control. Auxiliary Switch ZW2001 ZW2002 rev. 09/01/11 Z-Wave Certified Wireless Lighting Control Auxiliary Switch 45610 ZW2001 ZW2002 rev. 09/01/11 This auxiliary switch is a component of the JASCO Z-Wave lighting control system and is designed to work with

More information

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents. User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply

More information

LITETOUCH HYBRID WALL BOX DIMMER INSTALLATION INSTRUCTIONS

LITETOUCH HYBRID WALL BOX DIMMER INSTALLATION INSTRUCTIONS READ INSTRUCTIONS PRIOR TO INSTALLATION OF EQUIPMENT OR YOU MAY VOID THE WARRANTY! LITETOUCH INSTALLATION INSTRUCTIONS The LiteTouch Hybrid Wall Box Dimmer is a configurable lighting control device, that

More information

Wi-Fi Circa Switch or Dimmer Keypad

Wi-Fi Circa Switch or Dimmer Keypad The Savant Wi-Fi Circa Switch (WCS-1XXXXX) is a wall-box device which provides switch/relay (on/off) control of the connected lighting load or relay device such as lights, fans and fireplaces. The Savant

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215

More information

FDS / FDS-R / FDS-PS

FDS / FDS-R / FDS-PS FDS / FDS-R / FDS-PS USER MANUAL For use with 120V 60Hz input. Output is 120V 60Hz at 5amps 600W MAX. switched. ETL LISTED Conforms to UL STD 1241 3091594 79-15167-00 REV. A www.fiberstars.com Page 1 of

More information

INSTALLATION & SETUP GUIDE FOR SINGLE POLE & 3-WAY CONFIGURATIONS

INSTALLATION & SETUP GUIDE FOR SINGLE POLE & 3-WAY CONFIGURATIONS INSTALLATION & SETUP GUIDE FOR SINGLE POLE & 3-WAY CONFIGURATIONS idevices SMART HOME SOLUTIONS 1 REQUIRES Wi-Fi 2.4 GHz 802.11 b/g/n Compatible Network Router Security Settings Supported: WPA, WPA2, Or

More information

ETC Installation Guide

ETC Installation Guide Unison Foundry Overview The Unison Foundry provides fully-rated 20A relays for switched power control with 0 10V dimming for compatible fluorescent ballasts and LED drivers. The provides two outputs of

More information

QUICK INSTALL GUIDE READ ME FIRST XWC Package Contents: XWC-1000 Wireless Controller. Rack Mount Kit. Power Cord. Wireless Controller

QUICK INSTALL GUIDE READ ME FIRST XWC Package Contents: XWC-1000 Wireless Controller. Rack Mount Kit. Power Cord. Wireless Controller READ ME FIRST QUICK INSTALL GUIDE Wireless Controller WC-1000 Package Contents: WC-1000 Wireless Controller Rack Mount Kit Power Cord BEFORE YOU BEGIN INSTALLATION Access Point Firmware: Be sure that the

More information

TO AVOID FIRE, SHOCK, OR DEATH; SHUT OFF POWER SUPPLY AT THE CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING.

TO AVOID FIRE, SHOCK, OR DEATH; SHUT OFF POWER SUPPLY AT THE CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING. OWNER S MANUAL Congratulations on your purchase of a UPM timer. Please take the time to read and understand this manual so you can begin to enjoy the security and energy saving benefits this product has

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all safety information, warnings and cautions.

More information

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit Important Safety Messages SAVE THESE INSTRUCTIONS - This section contains important instructions that should be followed during installation

More information

400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual

400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual 400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual IO-70104 Rev 1, 1/2014 EMERSON NETWORK POWER SURGE PROTECTIVE DEVICE

More information

PV Rapid Shutdown device

PV Rapid Shutdown device PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

MCG Surge Protection

MCG Surge Protection 299-700-33B 299-700-33A MCG Surge Protection Installation/Operating Instructions for MCG 500 Series Important Warranty Information MCG surge protectors are designed to work at specific voltages and configurations,

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

READ ME FIRST QUICK INSTALL GUIDE. Wireless Controller XWC Includes: One: XWC-1000 Wireless Controller One: Rack Mount Kit One: Power Cord

READ ME FIRST QUICK INSTALL GUIDE. Wireless Controller XWC Includes: One: XWC-1000 Wireless Controller One: Rack Mount Kit One: Power Cord READ ME FIRST QUICK INSTALL GUIDE Wireless Controller XWC-1000 Includes: One: XWC-1000 Wireless Controller One: Rack Mount Kit One: Power Cord E E READ ME FIRST - COMPATIBILITY Your XWC-1000 Wireless Controller

More information

FIBARO SINGLE SWITCH

FIBARO SINGLE SWITCH OPERATING MANUAL EN FIBARO SINGLE SWITCH FGBHS-213 CONTENTS #1: Description and features 3 #2: Supported loads 4 #3: Installation 5 #4: Pairing the accessory 7 #5: Reset 8 v1.1 #6: Functionality 9 #7:

More information

Savant Wi-Fi Circa Controller

Savant Wi-Fi Circa Controller The Savant SmartLighting Wi-Fi Circa Controller (WCC-2XXXXX) is a compact, in-wall controller and dimmer in one, two-gang device. This can be installed as part of a complete package within Savant s automation

More information

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

More information

Z-Wave enabled 3-Way 15 Amp In-Wall Switch User Manual For Model HA18WD

Z-Wave enabled 3-Way 15 Amp In-Wall Switch User Manual For Model HA18WD Z-Wave enabled 15 Amp In-Wall User Manual For Model Thank you for purchasing the Z-Wave Enabled 15 Amp In-Wall. Z-Wave products by Wayne- Dalton allow you to manage and control your home by remote control

More information

Micro Smart Dimmer 2E manual. In-Wall Electrical Installation Instructions:

Micro Smart Dimmer 2E manual. In-Wall Electrical Installation Instructions: Micro Smart Dimmer 2E manual The following instructions have been designed to assist in the installation of the Aeotec by Aeon Labs Z-Wave in wall Smart Dimmer. Please note that the instructions are for

More information

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide *619751* P/N 619751 - Rev B IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS

More information

INSTEON KeypadLinc TM Dimmer (Rev 1.5+) INSTEON Keypad Dimmer. For models: KeypadLinc Dimmer 8-Button

INSTEON KeypadLinc TM Dimmer (Rev 1.5+) INSTEON Keypad Dimmer. For models: KeypadLinc Dimmer 8-Button INSTEON KeypadLinc TM Dimmer (Rev 1.5+) INSTEON Keypad Dimmer For models: #2486DWH6 #2486DWH8 KeypadLinc Dimmer 6-Button KeypadLinc Dimmer 8-Button TABLE OF CONTENTS ABOUT INSTEON KEYPADLINC DIMMER...4

More information

R SERIES INSTALLATION GUIDE

R SERIES INSTALLATION GUIDE R SERIES INSTALLATION GUIDE Welcome to your smartest install yet. Things you should know Latch R is a proximity reader, keypad, and wireless entry system, that can be operated as a standalone device or

More information

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

rcc.1081 Installation Instructions

rcc.1081 Installation Instructions rcc.1081 Installation Instructions Table of Contents Introduction...1 Specifications...2 Mounting...3 Wiring...5 Wiring Method...7 BACnet Network Wiring...8 Setting BACnet Address...9 Setting the BACnet

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

FX Supervisory Controller Wireless TEC Option Card Installation Instructions

FX Supervisory Controller Wireless TEC Option Card Installation Instructions Installation Instructions Wireless TEC Option Card Date August 29, 2014 FX Supervisory Controller Wireless TEC Option Card Installation Instructions Applications IMPORTANT: The FX Supervisory Controller

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data: Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your

More information

Installation Instructions

Installation Instructions SPECIFICATIONS TS-400 InteliSwitch Digital Time Switch 20/277VAC Voltages... 20/277VAC, 50/60Hz Requirements @ 20VAC... 0-800W ballast @ 277VAC... 0-200W ballast @ 25VAC.../6 hp Time-Out Adjustment...

More information

Mini Energy Dimmer MH-P210

Mini Energy Dimmer MH-P210 Mini Energy Dimmer MH-P210 Introduction Mini Energy Dimmer is a Z-Wave enabled module that can be set in existing in-wall switches. It supports basic command class, which can report immediate voltage,

More information

300 Series 330/320 Surge Protective Device Installation, Operation and Maintenance Manual

300 Series 330/320 Surge Protective Device Installation, Operation and Maintenance Manual Power Switching & Controls For Business-Critical Continuity 300 Series 330/320 Surge Protective Device Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual EMERSON

More information

Self-Adjusting Ultrasonic Wall Switch Sensor

Self-Adjusting Ultrasonic Wall Switch Sensor -1 06.09.05 Self-Adjusting Ultrasonic Switch Sensor The ultrasonic offers a direct and quick replacement of wall switches for stand-alone line voltage switching of small spaces. The intelligent, continuously

More information

Instruction Manual: IM E

Instruction Manual: IM E Innovative Technology TVSS Products The I.T. Equalizer Installation Instruction Manual: IM01005011E Rev. 2 May 2009 Contents Page 1 Introduction... 1 1.1 Scope... 1 1.2 I.T. Equalizer Catalog Numbering

More information

WASP Wireless Acceleration Sensor Puck USER MANUAL

WASP Wireless Acceleration Sensor Puck USER MANUAL WASP Wireless Acceleration Sensor Puck USER MANUAL VERSION 3.20 15/07/2016 WASP is a registered trademark owned by BossPac Engineering & Technology WASP is a PATENT PENDING technology owned by BossPac

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

M215-Z Safety Information (M LL-IG-ZC)

M215-Z Safety Information (M LL-IG-ZC) M215-Z SAFETY M215-Z Safety Information (M215-60-2LL-IG-ZC) This document contains important instructions to use during installation of the M215-Z Zep Compatible Microinverters. To reduce the risk of electrical

More information

Legrand Wireless Lighting

Legrand Wireless Lighting Legrand Wireless Lighting Installation in existing three-way circuits WARNING: PLEASE READ THIS ENTIRE GUIDE BEFORE BEGINNING INSTALLATION OF YOUR RF LIGHTING OR REMOVAL OF YOUR OLD SWITCH. INCORRECT INSTALLATION

More information

Rack Input Module Installation Instructions

Rack Input Module Installation Instructions Rack Input Module Installation Instructions DOC. #560105000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set

More information

P216 Series Condenser Fan Speed Controller

P216 Series Condenser Fan Speed Controller P216 Series Condenser Fan Speed Controller Installation Instructions P216xxx-x Part No. 24-85895-18, Rev. D Issued 27 August 2015 Applications Refer to the QuickLIT website for the most up-to-date version

More information

Satellite INSTALLATION GUIDE

Satellite INSTALLATION GUIDE N3 Satellite INSTALLATION GUIDE ! WARNING! Shock Hazard. May result in serious injury or death. Turn power OFF at circuit breaker or remove fuse. Damage to this product caused by wiring with power on voids

More information

2201 Rack Chassis User Manual

2201 Rack Chassis User Manual 2201 Rack Chassis User Manual CAUTION! This product may contain a laser diode operating at a wavelength of 1300 nm - 1600 nm. Use of optical instruments (e.g., collimating optics) with this product may

More information

Basketball Shot Clock Set LX2180 Manual

Basketball Shot Clock Set LX2180 Manual Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

Control Your World. Lighting Control System

Control Your World. Lighting Control System Lighting Control System Control Your World Today s homes have a wide variety of lights, dimmers and switches, indoors and out. Lighting control provides convenience, cost savings and an extra measure of

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs The IO-DI8-TO8 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 digital inputs,

More information

Always "On" UPS Systems Inc. USER MANUAL

Always On UPS Systems Inc. USER MANUAL Always "On" UPS Systems Inc. SMART HOME PROTECTOR USER MANUAL Bldg 1-150 Campion Road, Kelowna, BC, Canada, V1X 7S8 Phone: (250) 491-9777 Ext. 451, Fax: (250) 491-9775, Email: sales@alwaysonups.com Web

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

For Models #2384W/I (and Slave Remote Dimmer Model #1135W/I)

For Models #2384W/I (and Slave Remote Dimmer Model #1135W/I) SwitchLinc Lite Remote Control Dimmer Switch Owner s Manual For Models #2384W/I (and Slave Remote Dimmer Model #1135W/I) CONGRATULATIONS! You ve just purchased the highest quality powerline-controllable

More information

Temperature. Power requirements. Weight. Dimensions

Temperature. Power requirements. Weight. Dimensions Installing the Tracer Summit BMTX Building Control Unit Ordering numbers: BMTX001AAB000, BMTX001AAB010, BMTX001AAB001, BMTX001AAB011, BMTX001BAB000, BMTX001BAB010, BMTX001BAB001, BMTX001BAB011, BMTX001DAB000

More information

Installer manual. Eikon Arké Plana BUS EnOcean interface - 2 modules

Installer manual. Eikon Arké Plana BUS EnOcean interface - 2 modules Installer manual Eikon 20508 Arké 19508 Plana 14508 BUS EnOcean interface - 2 modules Instructions This manual is necessary in order to configure the radio-frequency devices when used with the By-me automation

More information

EcoView 8 DO Module Installation and Commissioning

EcoView 8 DO Module Installation and Commissioning Document No. 129-565 EcoView 8 DO Module Installation and Commissioning This document covers the installation and commissioning of the EcoView 8 DO Module. See the following documents for installation

More information

Installer manual. Eikon Arké Plana BUS EnOcean interface - 2 modules

Installer manual. Eikon Arké Plana BUS EnOcean interface - 2 modules Installer manual Eikon 20508 Arké 19508 Plana 14508 BUS EnOcean interface - 2 modules Instructions This manual is necessary in order to configure the radio-frequency devices when used with the By-me automation

More information

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017 APPLICATION CONTROL GUIDELINES IntelliROL Power Supply PN 1176718 Revision Date: March 15, 2017 Table of Contents List of Tables...3 TGW Safety Recommendation...4 Warnings and Safety Instructions...5 Introduction...6

More information

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS READ THIS MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS PRODUCT FEATURES MODELS: IIA SPRINT 310/510/710 200/250 2000 SERIES 3000 SERIES

More information

SmartVFD Disconnect Panel Assemblies

SmartVFD Disconnect Panel Assemblies SmartVFD Panel Assemblies INSTALLATION INSTRUCTIONS APPLICATION Only The SmartVFD Panel Assemblies channel electrical power either through or around the variable frequency drive (VFD). INSTALLATION When

More information

SignBOX II. Retrofit Guide for (X)WS201 and (X)WD201

SignBOX II. Retrofit Guide for (X)WS201 and (X)WD201 Scope: This procedure is designed to aid in the installation of SloanLED s SignBOX II illumination product and power supply products. Skilled tradespeople familiar with general construction, electrical

More information

Wiser EER260LLCR Load Control Control de carga EER260LLCR Contrôle de charge EER260LLCR

Wiser EER260LLCR Load Control Control de carga EER260LLCR Contrôle de charge EER260LLCR Wiser EER260LLCR Load Control Control de carga EER260LLCR Contrôle de charge EER260LLCR Installer s Guide / Guía de instalación / Guide de l'installateur S1A90300 Rev. 03, 08/2012 Retain for future use.

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

Installation Instructions

Installation Instructions LUCCI Slim Line Fan Remote Control SKU# 210012 Rated Voltage 220-240V~ 50Hz Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all instructions

More information

BoxLED DS Plus (Double Side) BX-DS-PL; BX12BA-W4F Signage Lighting System INSTALLATION GUIDE

BoxLED DS Plus (Double Side) BX-DS-PL; BX12BA-W4F Signage Lighting System INSTALLATION GUIDE www.osram-americas.com/signage BoxLED DS Plus (Double Side) BX-DS-PL; BX12BA-W4F Signage Lighting System INSTALLATION GUIDE WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION TO AVOID ELECTRICAL

More information

Wireless General Purpose Adapter (WGA100) Installation Instructions

Wireless General Purpose Adapter (WGA100) Installation Instructions (WGA100) Installation Instructions Daintree s WGA100 DT111 forms (Rev. part 12.8.17) of the Daintree ControlScope control solution for commercial and industrial buildings. It transmits and receives messages

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS READ THIS MANUAL CAREFULLY! FAILURE TO INSTALL THIS EQUIPMENT PER THESE INSTRUCTIONS WILL VOID THE WARRANTY. AM16904-1 Rev. C pg. 1 of 12 SPECIAL NOTICES The following notices

More information

Before you get started

Before you get started Installation Guide Before you get started If you ve installed light switches before and are comfortable with high voltage wiring, installing a Noon switch is easy. If not, we highly recommend hiring a

More information

AB Axis Industries. Use

AB Axis Industries. Use AB Axis Industries PULSE ADAPTER ENCO PULSE The ENCO PULSE pulse adapter acquires and handles the pulses from consumption meters with pulse output and transmits the data to a network of AMR system. Use

More information

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1

More information

Installation Manual. BN interface. Model name: BMS-IFBN640TLUL. English

Installation Manual. BN interface. Model name: BMS-IFBN640TLUL. English BN interface Model name: BMS-IFBN640TLUL English Contents Precautions for safety.................................................... 3 Introduction.............................................................

More information

Ink-Dot Series II Driver

Ink-Dot Series II Driver Instruction Sheet P/N 766B Ink-Dot Series II Driver Introduction See Figure. Ink-Dot Series II controllers can have from one to three driver modules. Any existing controller can easily be retrofit with

More information

M250 (M LL) Safety

M250 (M LL) Safety M250 SAFETY M250 (M250-60-2LL) Safety Important Safety Information This document contains important instructions to use during installation of the Enphase M250 Microinverter. To reduce the risk of electrical

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

Dell SC460 Expansion Enclosure Getting Started Guide

Dell SC460 Expansion Enclosure Getting Started Guide Dell SC460 Expansion Enclosure Getting Started Guide Regulatory Model: CYAE Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION:

More information

M215 Safety (M LL-S22-IG / S23-IG / S24-IG)

M215 Safety (M LL-S22-IG / S23-IG / S24-IG) M215 SAFETY M215 Safety (M215-60-2LL-S22-IG / S23-IG / S24-IG) Important Safety Information This document contains important instructions to use during installation of the Enphase M215 Microinverter. To

More information

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) 028-0296-R1-LIT-VC3000-E01 Index

More information

EcoSystem One-Line. EcoSystem C5-XPJ-16A Switching Power Module

EcoSystem One-Line. EcoSystem C5-XPJ-16A Switching Power Module EcoSystem Switching Power Module for Non-Dim Loads LutronR Switching Power Module allows integration of non-dim loads into Lutron s Bus. The Power Module combines digital commands and sensor data to control

More information

3M Wrist Strap and Ground Monitor 773. User s Guide

3M Wrist Strap and Ground Monitor 773. User s Guide 3M Wrist Strap and Ground Monitor 773 User s Guide Table of Contents Section Page Safety Information... 2 1 Description... 4 Overview... 4 Performance... 4 2 Installation... 5 Supplied Parts... 5 Wire

More information

PS/IO Circuit Board Retrofit

PS/IO Circuit Board Retrofit S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....

More information

M215 (M215-60) Safety

M215 (M215-60) Safety M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To

More information

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 Supersedes 6/2015 Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 XXCFXXX10-DIN Contents Description Page 1.0 Setup...2 1.1 Before Installation...2 1.2 Installation...3 For AC Applications...3

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS WARNING RISK OF SEVERE INJURY OR DEATH To reduce the risk of death,

More information

MTP INSTRUCTION MANUAL

MTP INSTRUCTION MANUAL DT-118B MTP INSTRUCTION MANUAL Pocket Autoranging Digital Multimeter 3 in 1 Model MTP-1025 Auto Ran ging DMM Hz% A OFF V AU TO PO WER OFF MTP Instruments Table of Contents Introduction Page 1 Features

More information

Network Camera. Quick Guide DC-S1283WRX. Powered by

Network Camera. Quick Guide DC-S1283WRX. Powered by Network Camera Quick Guide DC-S1283WRX Powered by Safety Precautions Important Safeguards WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

Installation Instructions

Installation Instructions SPECIFICATIONS TS-400 InteliSwitch Digital Time Switch 00/20/230/277VAC Voltages....................... 00-277VAC, 50/60Hz Load Requirements @ 00/20VAC..................... 0-800W ballast @ 230/277VAC....................

More information