Remote RMX-3200 Intelligent Site Management Device. Installation Guide

Size: px
Start display at page:

Download "Remote RMX-3200 Intelligent Site Management Device. Installation Guide"

Transcription

1 Remote RMX-3200 Intelligent Site Management Device Installation Guide INSTALLATION GUIDE Westell Technologies Part # Rev. A

2 Copyright 2015 by Westell Technologies. All Rights Reserved. Westell, Kentrox and Optima Management System are registered trademarks of Westell. All other names are trademarks of their respective owners. Information is correct at time of publication and is subject to change without notice. Contact Westell in Aurora, Illinois, to verify current product information. Westell Inc. is an Equal Opportunity/Affirmative Action employer. Westell Technologies 750 North Commons Aurora, IL USA Toll Free: (800) International: +1 (630) Fax: +1 (630) Page 0

3 Remote RMX-3200 Intelligent Site Management Device Installation Guide This installation guide explains how to install the Remote RMX-3200 intelligent remote site management device. Also included is hardware information about expansion cards that can be plugged into Remote RMX-3200 s expansion slot, and the RMB peripheral units that can be powered from one of Remote RMX-3200 s PoE ports. Instructions for use of this product are detailed in the following documents: Remote RMX-3200 Command Reference Guide Remote RMX-3200 Configuration Guide Kentrox Remotes Web Interface User Guide RMB Installation Guide Guide to this document Product Components Cautions and Warnings Customer Assistance Required Items Installation Maintaining and Replacing the Fan Technical Specifications Page 1

4 Product Components Product Components Pin Console Port 8 1 Signal RTS DTR TXD Ground Ground RXD DSR CTS Fan (shown with fan filter assembly installed) Direction Output Output Output Input Input Input Refer to pin assignments J8 Port on page 4 Refer to pin assignments J9 Port on page 4 Unit Status LEDs LED Status LED Description ALARM Summary alarm LED: Illuminated when any point is in alarm state FAULT Hardware failure LED: Illuminated when processor is not functioning DC OK DC Input Power LED: Illuminated when valid DC Input Power is applied to the unit APR OK Alarm Power Health LED: Illuminated when 24V power output is present Chassis Ground ESD Ground Expansion Slot Ethernet Switch Ports Asynchronous Serial Ports Output Power Connection (+24VDC) Input Power Connections Page 2

5 Product Components Front Panel Components - Remote RMX-3200 Alarm I/O Port Pin Table J8 Port J9 Port Pin Signal Ground Bistate input 1 Bistate input 2 Bistate input 3 Bistate input 4 Bistate input 5 Bistate input 6 Bistate input 7 9 Bistate input 8 10 Bistate input 9 11 Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Ground Pin Signal 26 Ground 27 Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Ground 37 Ground 38 Control output 1, normally closed 39 Control output 1, common 40 Control output 1, normally opened 41 Control output 2, normally closed 42 Control output 2, common 43 Control output 2, normally opened 44 Control output 3, normally closed 45 Control output 3, common 46 Control output 3, normally opened 47 Control output 4, normally closed 48 Control output 4, common 49 Control output 4, normally opened 50 Ground Pin Signal Ground Bistate input 33 Bistate input 34 Bistate input 35 Bistate input 36 Bistate input 37 Bistate input 38 Bistate input 39 9 Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Ground Pin Signal 26 Ground 27 Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Ground 37 Ground 38 Analog Input 1 39 Analog Input 2 40 Analog Input 3 41 Analog Input 4 42 Analog Input 5 43 Analog Input 6 44 Analog Input 7 45 Analog Input 8 46 Analog Input 9 47 Analog Input Analog Input Analog Input Ground Page 3

6 Product Components Front Panel Components - 8-Port Serial Expansion Card RS-232 Mode RS-422 Mode Pin Signal RTS DTR TXD Ground Ground RXD DSR CTS Direction Output Output Output Input Input Input Pin Signal Direction No connection TX- Output TX+ Output Ground Ground RX+ Input RX- Input No connection Note: This expansion card does not support RS485 mode. Page 4

7 Product Components Front Panel Components - Alarm Expansion Card J J Pin Signal Ground Bistate input 1 Bistate input 2 Bistate input 3 Bistate input 4 Bistate input 5 Bistate input 6 Bistate input 7 9 Bistate input 8 10 Bistate input 9 11 Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Ground Pin Signal 26 Ground 27 Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Ground 37 Ground 38 Control output 1, normally-closed 39 Control output 1, common 40 Control output 1, normally-opened 41 Control output 2, normally-closed 42 Control output 2, common 43 Control output 2, normally-opened 44 Control output 3, normally-closed 45 Control output 3, common 46 Control output 3, normally-opened 47 Control output 4, normally-closed 48 Control output 4, common 49 Control output 4, normally-opened 50 Ground Pin Signal Ground Bistate input 33 Bistate input 34 Bistate input 35 Bistate input 36 Bistate input 37 Bistate input 38 Bistate input 39 9 Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Ground Pin Signal 26 Ground 27 Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Bistate input Ground 37 Ground 38 Analog Input 1 39 Analog Input 2 40 Analog Input 3 41 Analog Input 4 42 Analog Input 5 43 Analog Input 6 44 Analog Input 7 45 Analog Input 8 46 Analog Input 9 47 Analog Input Analog Input Analog Input Ground Page 5

8 Product Components Front Panel Components - Ethernet Expansion Card Page 6

9 Product Components Front Panel Components - RMX WWAN TX/RX- SMA Female- Cellular/PCS Antenna RX Diversity- SMA Female- Cellular/PCS Antenna Networks Supported RMX WWAN models are available for various carriers and technologies. Consult Kentrox for further information. Note: Antenna 2 connections are reserved for future use. Page 7

10 Product Components Front Panel Components - RMX WTE Serial WAN Port 1 8 Pin Signal RRING RTIP No connection TRING TTIP No connection No connection No connection Direction Input Input Output Output Table 1 LED Functionality for RMX WTE Serial WAN Ports Red LED Green LED Condition Off Off Remote RMX-3200 is not powered, or is booting up. On On Remote RMX-3200 is performing an LED test. Off On Normal. No alarm condition exists. On Off An out-of-frame (OOF) or loss-of-signal (LOS) alarm exists. Flashing (1Hz) Flashing (4Hz) On On A T1 Remote Alarm Indication (RAI), or yellow alarm signal, exists. An Alarm Indication Signal (AIS) exists. Page 8

11 Product Components Table 1 LED Functionality for RMX WTE Serial WAN Ports (Continued) Flashing (1Hz) Off On Off Flashing (1Hz) Flashing (1Hz) Low signal threshold has been exceeded. A line or payload loopback condition exists or a BERT code is being sent. An alarm condition exists, and a line or payload loopback condition exists or a BERT code is being sent. Flashing Flashing The port is configured as the standby port in a redundant group. No alarm condition exists. Page 9

12 Product Components Front Panel Components - Gigabit Ethernet Expansion Card 1000baseT WAN Ports (1GB Mode) Page 10

13 Product Components 1000baseT WAN Ports (10/100 Mode) SFP WAN Ports The fiber SFP ports on RMX WGBE support small form-factor pluggable (SFP) transceivers. Consult Kentrox for supported SFP options. Page 11

14 Cautions and Warnings Cautions and Warnings Grounding and Electrical Safety Installation CAUTION: Kentrox equipment and its peripherals contain electrostatic sensitive components. Proper handling, shipping, and storage precautions must be exercised. CAUTION: For Kentrox equipment to operate safely and correctly, there must be a safety ground strap between the equipment ground bolts and the office ground. Environment CAUTION: In the event that Remote RMX-3200 has been subjected to adverse environmental conditions, a service inspection of Remote RMX-3200 should be made to ensure safe operation. Lithium Batteries CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. Internal Cooling Fan CAUTION: The internal fan on Remote RMX-3200 is not user-serviceable. Should the fan fail to operate, customers may either contact Westell Customer Assistance to return the Remote RMX-3200 device for repair or replacement; or follow the enclosed instructions for Maintaining and Replacing the Fan. Estimated mean time to disconnect your Remote RMX-3200 from the network and replace it with a new device is one hour. Restricted Access Locations CAUTION: The Remote RMX-3200 is for use in restricted access locations only. Page 12

15 Cautions and Warnings NEBS Compliance Requirements CAUTION: The intra-building ports, including Ethernet, asynchronous, and discrete input ports, of the equipment or subassembly are suitable for connection to intra-building or unexposed wiring or cabling only. The intra-building ports of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the OSP or its wiring. These interfaces are designed for use as intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring. Laser Radiation The intra-building ports, including Ethernet, asynchronous, and discrete input ports, of the equipment or subassembly must use shielded intrabuilding cabling/wiring that is grounded at both ends. LASER DANGER: The WGBE expansion card uses Class IIIb laser devices. Invisible laser radiation is present when the optic connectors are open. Always avoid direct or scattered exposure to the beam when servicing or installing customer cables. Also avoid exposure from receive cables connected to any laser device. FCC The Federal Communications Commission has set limits for emitted radio interference, and Remote RMX-3200 is constructed with this electromagnetic interference (EMI) limitation in mind. Remote RMX-3200 is classified under FCC regulations as a Class A device, that is, a device for use in commercial environments and not in residential areas. This device has been tested and shown to comply with the following FCC rule: Part 15 Subpart J. Operation of this equipment in a residential area may cause interference to radio and TV reception, requiring the user to take whatever steps are necessary to correct the interference. Information is available from the FCC describing possible corrective actions. To maintain low EMI levels, we suggest that you use only metal connectors and shielded cable grounded to the frame. Remote RMX-3200 complies with 47 CFR, Part 68 of the rules. On the top of Remote RMX-3200 is a label that contains, among other information, the certification number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company. If the terminal equipment Remote RMX-3200 uses causes harm to the telephone network, the telephone company will notify you in advance that temporary Page 13

16 Cautions and Warnings discontinuance of service may be required. But if advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service. If trouble is experienced with Remote RMX-3200, for repairs or warranty information, please contact Kentrox, Inc. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved. Specifications are subject to change without notice. Page 14

17 Customer Assistance Customer Assistance All customers, partners, and resellers who have a valid Westell Support and Services Agreement have complete access to the technical support resources. Pre-sales Support Westell offers pre-sales technical support from 9 a.m. to 5 p.m. Eastern time, Monday - Friday. Representatives are standing by to assist with customer account information and product ordering and answer questions regarding Westell products and solutions. Phone number: , option 1 Before you call or Before you contact Westell for assistance, please have the following information available: The versions of hardware and software you are currently running The error number and exact wording of any messages that appeared on your screen What happened and what you were doing when the problem occurred How you tried to solve the problem Technical Support support is available. You may send at any time during the day; however, responses will be provided only during normal business hours, in accordance with your Service and Support Agreement. To contact Technical Support, send to: support@westell.com Telephone Technical Support Available to qualified Westell customers or partners who have not been able to resolve their technical issue by using our online services. To qualify for support, you must have a valid Support and Services Agreement. Phone number: , option 2 Normal Business Hours: 8 a.m. to 6 p.m. Eastern time After-Hours Support: Available to qualified customers who are experiencing serviceaffecting outages that cannot wait until the next business day. To qualify for after-hours support, you must have a valid 24x7 Support and Services Agreement. Call the number above, option 2, and follow the prompts for after-hours service. Page 15

18 Customer Assistance Product Documentation You can also access and view the most current versions of Kentrox product documentation on our web site at: Page 16

19 Required Items Required Items Tools Materials #2 Phillips screwdriver Small flathead screwdriver (Phoenix 3 mm, recommended) 3/32 in. slotted screwdriver Crimping tool Wire cutter Wire stripper Grounding wrist strap Voltmeter, DC range PC with terminal emulation software such as Procomm 10mm nut driver Four screws, sized to fit your rack Wire for input power connections (16 AWG solid or stranded insulated) Wire for ground connection (14 AWG, copper conductor) Ground lugs for rack or other earth ground Antioxidant Various required rack cables and cable assemblies (For fan replacement only) Westell Part # (fan) (For fan replacement only) Westell Part # (fan filter assembly) Page 17

20 Installation Installation Step 1: Attach Mounting Flanges and Cable Tray Attach the mounting flanges to fit a 19-inch or 23-inch rack. You can also attach the flanges in three locations providing multiple alignment options to the rack. The mounting flanges can be used to attach the optional cable management bar, as shown below. Fan opening Mounting flanges for a 19-inch rack Mounting flanges for a 23-inch rack Step 2: Attach Remote RMX-3200 to Rack Install mounting screws into the mounting holes and tighten firmly. No space is required between Remote RMX-3200 and any component mounted above or below Remote RMX Page 18

21 Installation Step 3: Attach Chassis Ground Connect the chassis ground of Remote RMX-3200 to a suitable ground such as the frame ground of the rack system or a reliable earth ground. Caution: The chassis ground must be connected to the same earthing electrode conductor as the DC supply system or to a bonding jumper (from an earthing terminal or bus) connected to the earthing electrode of the DC supply system. The chassis must be located in the same immediate area (such as adjacent cabinets) as other equipment connected to the same DC power system and earthing electrode conductor. The DC system cannot be earthed elsewhere. The DC power source must be located in the same premises as the chassis. No switching or disconnecting devices can occur between the earthed conductor of the DC source and the earthing electrode conductor. Note: Apply an appropriate antioxidant to the bare conductors before crimping the connector to the connector mating surface. Note: For ground connection, use 14AWG or larger conductor. Step 4: Connect Input Power WARNING: Turn off the power feed before connecting wires. Connect the input power feed to the power supply connector. Be careful to observe polarity. Page 19

22 Installation Caution: A readily accessible disconnect device (suitably approved and rated) must be incorporated in the field wiring. Unscrew these two screws to remove the power connector, if necessary. To connect wires: 1. Turn off power feed. Loosen these four screws before inserting wire into connector. 2. Strip ends of wire 5/16 in. (7 mm). 3. (optional) Using a small flathead screwdriver, loosen screws on sides of power connector on rear panel of Remote RMX (optional) Remove power connector. 5. Using a 3/32 in. slotted screwdriver, loosen the four screws at top of connector. Connect power connector to a reliably grounded -48 VDC safety extra-low voltage (SELV) source. Use 16 AWG or larger copper conductors. Typical circuit fuse: 3 A Page 20

23 Installation Step 5: Connect Inputs and Outputs Input and output connections are made using a wire wrap distribution panel. Some wire wrap distribution panels include pins marked +24V IN, +24 OUT, GND IN, and GND OUT. To power external devices (such as analog sensors), you can connect the + terminal of Remote RMX-3200 s 24VDC output power connection to the +24V IN pins and connect the - terminal of Remote RMX-3200 s 24VDC output power connection to the GND IN pins. You can then connect the + terminal of an external device to the +24 OUT pins and the - terminal of the external device to the GND OUT pins. The multiple pins are present to accommodate the current-carrying limitations of individual strands of CAT5 wire. For instructions on physically mounting the panel, see section Rack-Mounting the Wire Wrap Distribution Panel on page 27. Table 2 Terminal Block Wet Mount Pin Table BLOCKB64WET Connector:Pin Number Signal/Description Ground (top-left pin) J8:1 Ground D1 J8:2 Digital input 1 D2 J8:3 Digital input 2 D3 J8:4 Digital input 3 D4 J8:5 Digital input 4 Page 21

24 Installation Table 2 Terminal Block Wet Mount Pin Table (Continued) BLOCKB64WET Connector:Pin Number Signal/Description D5 J8:6 Digital input 5 D6 J8:7 Digital input 6 D7 J8:8 Digital input 7 D8 J8:9 Digital input 8 D9 J8:10 Digital input 9 D10 J8:11 Digital input 10 D11 J8:12 Digital input 11 D12 J8:13 Digital input 12 D13 J8:14 Digital input 13 D14 J8:15 Digital input 14 D15 J8:16 Digital input 15 D16 J8:17 Digital input 16 D17 J8:18 Digital input 17 D18 J8:19 Digital input 18 D19 J8:20 Digital input 19 D20 J8:21 Digital input 20 D21 J8:22 Digital input 21 D22 J8:23 Digital input 22 D23 J8:24 Digital input 23 Ground J8:25 Ground Ground J8:26 Ground D24 J8:27 Digital input 24 D25 J8:28 Digital input 25 D26 J8:29 Digital input 26 D27 J8:30 Digital input 27 D28 J8:31 Digital input 28 D29 J8:32 Digital input 29 D30 J8:33 Digital input 30 D31 J8:34 Digital input 31 Page 22

25 Installation Table 2 Terminal Block Wet Mount Pin Table (Continued) BLOCKB64WET Connector:Pin Number Signal/Description D32 J8:35 Digital input 32 Ground J8:36 Ground Ground J8:37 Ground NC1 J8:38 Normally closed contact 1 C1 J8:39 Common contact 1 NO1 J8:40 Normally open contact 1 NC2 J8:41 Normally closed contact 1 C2 J8:42 Common contact 2 NO2 J8:43 Normally open contact 2 NC3 J8:44 Normally closed contact 3 C3 J8:45 Common contact 3 NO3 J8:46 Normally open contact 3 NC4 J8:47 Normally closed contact 4 C4 J8:48 Common contact 4 NO4 J8:49 Normally open contact 4 Ground J8:50 Ground Ground J9:1 Ground D33 J9:2 Digital input 33 D34 J9:3 Digital input 34 D35 J9:4 Digital input 35 D36 J9:5 Digital input 36 D37 J9:6 Digital input 37 D38 J9:7 Digital input 38 D39 J9:8 Digital input 39 D40 J9:9 Digital input 40 D41 J9:10 Digital input 41 D42 J9:11 Digital input 42 D43 J9:12 Digital input 43 D44 J9:13 Digital input 44 Page 23

26 Installation Table 2 Terminal Block Wet Mount Pin Table (Continued) BLOCKB64WET Connector:Pin Number Signal/Description D45 J9:14 Digital input 45 D46 J9:15 Digital input 46 D47 J9:16 Digital input 47 D48 J9:17 Digital input 48 D49 J9:18 Digital input 49 D50 J9:19 Digital input 50 D51 J9:20 Digital input 51 D52 J9:21 Digital input 52 D53 J9:22 Digital input 53 D54 J9:23 Digital input 54 D55 J9:24 Digital input 55 Ground J9:25 Ground Ground J9:26 Ground D56 J9:27 Digital input 56 D57 J9:28 Digital input 57 D58 J9:29 Digital input 58 D59 J9:30 Digital input 59 D60 J9:31 Digital input 60 D61 J9:32 Digital input 61 D62 J9:33 Digital input 62 D63 J9:34 Digital input 63 D64 J9:35 Digital input 64 Ground J9:36 Ground Ground J9:37 Ground A1 J9:38 Analog input 1 A2 J9:39 Analog input 2 A3 J9:40 Analog input 3 A4 J9:41 Analog input 4 A5 J9:42 Analog input 5 Page 24

27 Installation Table 2 Terminal Block Wet Mount Pin Table (Continued) BLOCKB64WET Connector:Pin Number Signal/Description A6 J9:43 Analog input 6 A7 J9:44 Analog input 7 A8 J9:45 Analog input 8 A9 J9:46 Analog input 9 A10 J9:47 Analog input 10 A11 J9:48 Analog input 11 A12 J9:49 Analog input 12 Ground J9:50 Ground CAUTION: Kentrox recommends turning off the power to Remote RMX-3200 before wiring the alarm inputs. This avoids shorting wire wrap pins. If this is not possible, it is recommended that the alarm connector be unplugged before wiring the alarm inputs. CAUTION: Do not exceed 600 ma. To prevent damage to Remote RMX-3200, the total current draw from the alarm power output pins (+ and -) must not exceed 600 ma. Page 25

28 Installation Rack-Mounting the Wire Wrap Distribution Panel To mount the wire wrap distribution panel in a rack: 1. Locate the four square holes in the back of the wire wrap distribution panel. Through each of the two innermost holes, insert an 8-32 x 5/8" carriage bolt so the threads protrude to the rear of the panel as shown in the figure below. When the bolt is seated, the square base of the carriage bolt should fit in the hole to prevent the bolt from rotating. 2. Fit the carriage bolts through the corresponding holes in the mounting bar, then secure the bar to the panel by threading an 8-32 hex nut with lock washer onto each bolt. Note: The mounting bar can accept two wire wrap distribution panels mounted side-by-side. This arrangement is shown in the figure on the following page. Page 26

29 Installation 3. Secure the mounting bar to the rack as follows: a. For a 19 rack, fit screws through the holes in each end of the mounting bar, then tighten the screws into the threaded holes in the rack. b. For a 23 rack, fit screws through the holes in each end of the mounting bar, then tighten the screws into threaded holes in a pair of mounting flanges. Screw the mounting flanges into the threaded holes in the rack. This arrangement is shown in the photo below. Step 6: (optional) Mount RMB Mount the RMB peripheral unit to the wall, or in a rack. See the RMB Installation Guide for instructions. Step 7: (optional) Connect RMB Inputs and Outputs RMB input and output connections are made using the supplied punchdown tool. See the RMB Installation Guide for an explanation of RMB inputs and outputs. Step 8: Connect the Port Cables Connect all port cables per your application. Securely fasten all cables to the tie bars. Connecting to the Console Port The console port provides local access to Remote RMX-3200 for diagnostic and configuration purposes. Use one of the following to connect the console port (labeled CONSOLE on the Remote RMX-3200 front panel) to COM port 1 on your PC or laptop: RJ45 to DB9 adapter (part number 77910) and 10 CAT5 cable (part number CAB182-10), included with Remote RMX pin modular plug to female DB-9 null cable (part number CAB562) 8-pin modular plug to female DB-25 null cable (part number CAB564) Page 27

30 Installation Note: Your specific application may require a cable other than those listed above. Connecting to an Asynchronous Serial Port Asynchronous serial ports allow terminal devices with asynchronous serial ports (such as PCs, NEs, and asynchronous modems) to connect to Remote RMX Use one of the following cables to connect one of the asynchronous serial ports (labeled ASYNC SERIAL PORTS on the front panel) to an external device, such as a modem: 8-pin modular plug to 8-pin modular plug rollover DTE to DTE null RS-232 cable (part number CAB213) Male DB-25 to 8-pin modular plug DTE to DCE straight cable (part number CAB214) for temporary console access Female DB-25 to 8-pin modular plug DTE to DTE null RS-232 cable (part number CAB564) for temporary console access Female DB-9 to 8-pin modular plug DTE to DTE null RS-232 cable (part number CAB562) for temporary console access All serial interfaces other than temporary console access must use shielded cable for FCC compliance. Connecting to a Serial WAN Port Serial WAN ports (provided by the optional RMX WTE WAN module) allow you to connect Remote RMX-3200 to a WAN either directly or through another device, such as a DSX panel or a T1 or E1 router. When Remote RMX-3200 is connected to a WAN, you can access other networks. Use one of the following cables to connect one of the serial WAN ports (labeled SERIAL WAN on the RMX WTE front panel) to another device on a WAN: 8-pin modular plug to 8-pin modular plug null cable (part number CAB502) CSU/DSU modular plug to 8-pin modular plug cable (part number CAB228) Note: Your specific application may require a cable other than those listed above. Note: Use shielded cable to ensure compliance with applicable emission standards. Note: Serial WAN connections made through RMX WTE are rated for intrabuilding connections. They are not rated for surges that may result from interbuilding connections (for example, lightning strikes). Connecting to an Ethernet Port The switched Ethernet ports allow you to connect Ethernet-capable devices to Remote RMX-3200 and allow you to connect Remote RMX-3200 to a LAN. The optional RMX WGBE module adds two Gigabit Ethernet (1000baseT) ports. Page 28

31 Installation Use one of the following cables to connect one of the switched Ethernet ports (labeled ETHERNET on the Remote RMX-3200 front panel) to an Ethernet device on your network: 8-pin modular plug to 8-pin modular plug crossover 10/100BaseT cable (part number CAB542) 8-pin modular plug to 8-pin modular plug straight 100BaseT cable (part number CAB182) Note: Your specific application may require a cable other than those listed above. When connecting to one of RMX WGBE s Gigabit Ethernet ports, use CAT6 cable for optimal performance. Connecting to a Fiber SFP Port Fiber SFP ports (provided by the optional RMX WGBE module) support small formfactor pluggable (SFP) transceivers. Consult Kentrox for supported SFP options. Connecting to a Digital Input You can connect a digital input on Remote RMX-3200 to a contact or relay output on a monitored device, such as a magnetic door switch. When an event occurs, such as a door opening or closing, the switch opens or closes. Remote RMX-3200 responds by generating an event. Use the Kentrox wet block kit (part number BLOCKB64WET) to make digital input connections to Remote RMX Consult Kentrox for other distribution options. Connecting to an Analog Input You can connect an analog input on Remote RMX-3200 to a 4 to 20 ma current loop or a 0 to 10 VDC transducer, which converts a physical input to a current or voltage output. For example, the physical input could be the temperature or voltage which is then converted into a current between 4 ma and 20 ma or 0 to 10 VDC. Remote RMX can be configured to generate events when current thresholds are crossed, or to report input current values at intervals. Use the Kentrox wet block kit (part number BLOCKB64WET) to make analog input connections to Remote RMX Consult Kentrox for other distribution options. Connecting to a Relay Output You can connect a relay output on Remote RMX-3200 to control a device. Use the Kentrox wet block kit (part number BLOCKB64WET) to make relay output connections to Remote RMX Consult Kentrox for other distribution options. Connecting RMX-3200 to RMB (optional) Page 29

32 Installation Use a standard CAT5 Ethernet cable (such as Kentrox part number CAB182-10) to connect one of RMM-1400 s PoE-enabled Ethernet ports to the Ethernet port on RMB. CAUTION: Kentrox recommends disconnecting the Ethernet PoE cable to RMB before wiring inputs and outputs in order to avoid electrical shorts. Step 9: (optional) Configure an IP Address Configuring the IP address allows Remote RMX-3200 to be accessed remotely. To configure the IP address: 1. Set the terminal emulation software on the PC or terminal emulator to 9600 baud, no parity, eight data bits, one stop bit, and XON/XOFF flow control. 2. Use a terminal cable to connect the PC or terminal to the Remote RMX-3200 console port and press ENTER. 3. At the prompt, enter admin. This is the default login. 4. At the password prompt, enter password. This is the default password. 5. At the command prompt enter config interface bridge switch ip address, followed by the IP address and subnet mask. For example: config interface bridge switch ip address At the command prompt, enter config ip route default and the default gateway address. For example: config ip route default Page 30

33 Maintaining and Replacing the Fan Maintaining and Replacing the Fan Fan Inspection and Maintenance Westell recommends inspecting the fan built into Remote RMX-3200 every six months. The inspector should make sure the fan is operating, the opening is not obstructed, and the filter is clean. Clean or replace the filter if needed (see instructions below). If the fan is making noise, replacement is advisable. Cleaning the Fan Filter Westell recommends cleaning or replacing the fan filter every three to six months. Fan filters need to be replaced at least every two to three years to ensure media reliability and eliminate residual dust buildup and subsequent airflow resistance. 1. Remove the filter from the housing on the front of Remote RMX-3200 prior to initiating cleaning. 2. The filter may be cleaned using slightly compressed air, a vacuum, mild detergent, and/or clean water. If cleaning with compressed air or vacuum only, the dry filter can be reinstalled immediately. 3. If cleaning with water: The filter should be completely dry before reinstallation. Use only a mild detergent, such as dishwashing liquid, if degreasing is necessary. Avoid using harsh solvents or cleaning agents. 4. Also clean the filter housing and the filter mounting location on Remote RMX prior to reinstallation of the filter. Use only a dry cloth or swab to clean Remote RMX Fan Replacement Procedure If the fan built into Remote RMX-3200 fails to operate, follow these steps to replace it. Note: Because of the difficulty involved with this replacement procedure, customers may instead contact Westell Customer Assistance to return the Remote RMX for fan replacement service. CAUTION: This procedure involves opening the Remote RMX-3200 s external housing. Great care needs to be taken to avoid damaging the internal components. Use an antistatic wrist strap throughout the procedure, and work on antistatic mats if possible. Avoid touching the circuit board and other components unnecessarily with hands, tools, or anything else. Work in a clean, dry environment so the circuitry is not exposed to moisture, dirt, dust, or anything else which could cause damage. Page 31

34 Maintaining and Replacing the Fan 1. Obtain a replacement fan and filter assembly by contacting Westell Customer Assistance. Order: Westell Part # (fan) Westell Part # (fan filter assembly). 2. Disconnect power from Remote RMX-3200 and disconnect all wires from the device. 3. Remove the fan filter assembly from the front of Remote RMX Detach Remote RMX-3200 from its rack and remove the mounting flanges. 5. Remove the four screws holding the Remote RMX-3200 s top cover in place. These are located on the sides of the housing near the back, with two on each side. 6. Use a small flathead screwdriver to pry the top cover of Remote RMX-3200 backward from the front face of the housing. Once the top cover is pried about 2-3 mm backwards, use your hands to continue pushing the top cover backwards until it can be removed. 7. Remove the card or other device from the Remote RMX-3200 expansion slot. Fan Mounting Bracket Power and Control connection Fan installed in Remote RMX-3200 viewed from the left rear with the top cover and expansion card removed and the mounting bracket and power and control connections in place 8. Remove the mounting bracket holding the fan in place by removing the single screw and lifting the bracket. See the photo above. 9. Slide the fan as far back as it will go. Then, working from in front of the device, use both thumbs to press gently but firmly to tilt the top of the fan backwards until it snaps free from the top lip of the front housing. See the following photo. Page 32

35 Maintaining and Replacing the Fan CAUTION: Leave the fan power and control wires connected while removing the fan to guard against impaling thumbs on the connector pins protruding upward from the circuit board. See the following photo. Press down and back to tilt fan until it snaps free To guard against impaling thumbs on these connector pins, leave the fan power.and control wires connected while removing the fan. Removing the fan 10. Disconnect the power and control wires and remove the fan. 11. Connect the replacement fan s power and control wires and snap the fan into place using the reverse of the removal procedure. 12. Replace the fan mounting bracket. Be sure the two bracket tabs go into the bottom holes on the fan housing to hold the fan securely in place. 13. Reinstall the expansion card or other device in the expansion slot. 14. Reinstall the top cover on Remote RMX Replace the fan filter with the new filter and reinstall the filter assembly on the front of Remote RMX Reinstall the mounting flanges, mount Remote RMX-3200 on the rack, and reconnect the power and all other wire connections. 17. Verify that the replacement fan is operating. Page 33

36 Technical Specifications Technical Specifications Table 3 Technical Specifications Specification Weight Size Mounting Operating Environment (Ambient) Power Fuse Ratings Protocol Mediation Input/Output Ports Description 8.5 lb (3.86 kg) Height: 1.75 in. (4.45 cm) Width: in. (42.8 cm) Depth: 12 in. (30.8 cm) Mounts in a standard 19-in. or 23-in. rack Temperature: -40 to 65 C Relative humidity: 0% to 95% (non-condensing) Input power: 11 watts minimum, 60 watts maximum (see section Calculating Power Consumption and Heat Dissipation on page 36) Input voltage range: +/- 20 to 60VDC (both power feeds must have the same polarity) Voltage applications: +24VDC and -48VDC 3 A at 60 VDC Asynchronous, TL1 Multiplexing, Virtual TL1 Network Elements 1 console port 8 10/100 BaseT Ethernet switch ports, 2 with 802.3af-compliant PoE 8 asynchronous serial ports (RS-232/RS-422/RS-485) 64 digital inputs, pre-wetted with common ground 12 analog inputs: Voltage mode: Range: +/- 0 to 10 VDC Input impedance: greater than or equal to 1 mega Ohm Current mode: Range: 4 to 20 ma DC Input impedance: 100 Ohm Accuracy: +/-2% of full-scale 4 relay outputs: Contact rating: 30 VDC at 2 A resistive Contact type: Form C 1 slot for an optional expansion peripheral or WAN module VDC power output 0.6A rated output Page 34

37 Calculating Power Consumption and Heat Dissipation Calculating Power Consumption and Heat Dissipation To calculate power consumption and heat dissipation for Remote RMX-3200: 1. Use Table 4 to calculate power consumed internally by Remote RMX Enter in the Subtotals column the resources used and any interface module that may be installed. Add the Subtotals values to obtain the internal power consumption. Table 4 Calculating Internal Power Consumption Resource Power Subtotals Remote RMX-3200 base unit 11W 11W Ethernet ports (linked) 0.25W x port count W Expansion card, if present (will be ONE of the following): RME-S8 Serial Expansion Card (3.2W) RME-B64 Alarm Expansion Card (4.0W) RME-E8 Ethernet Expansion Card (6.5W) RMX-WWAN-XX Expansion Card (5.0W) RMX-WTE-XX Expansion Card (3.4W) RMX-WGBE Expansion Card (5.0W) W External sensor power used x 0.2W W PoE power used (each RMB peripheral consumes 15W maximum, plus 0.1W in losses) Internal Power Consumption x 0.1W W = W 2. Use Table 5 to calculate total chassis heat dissipation. Enter the internal power consumption value from Table 4 in the first blank, then multiply by the conversion factor 3.41 to obtain total chassis heat dissipation in Btu/hr. Table 5 Calculating Total Chassis Heat Dissipation Total Internal Power Consumption (from Table 4) W Conversion factor x 3.41 Total Chassis Heat Dissipation = Btu/Hr 3. Use Table 6 to calculate total input power. Enter the internal power consumption value from Table 4 in the first blank, then add external sensor power and PoE power used to obtain total input power. Page 35

38 Calculating Power Consumption and Heat Dissipation Table 6 Calculating Total Input Power Total Internal Power Consumption (from Table 4) External sensor power used PoE power used Total Input Power W W W W Page 36

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide Remote RMM-1400 Intelligent Remote Site Management Device Guide INSTALLATION GUIDE Westell Technologies Part # 030-300645 Rev. A Copyright 2015 by Westell Technologies. All Rights Reserved. Westell, Kentrox

More information

RMB Peripheral Units Installation Guide

RMB Peripheral Units Installation Guide RMB Peripheral Units Installation Guide Part Number 65-000101 2011 by Kentrox, Inc. All rights reserved. Copyright 2011 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication

More information

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A RMB-3 Peripheral Unit Installation Guide INSTALLATION GUIDE Westell Technologies Part # 030-300812 Rev. A Copyright 2017 by Westell Technologies. All Rights Reserved. The material discussed in this publication

More information

INSTALLATION GUIDE. Remote RMM-700 Intelligent Site Management Device. Installation Guide WESTELL.COM

INSTALLATION GUIDE. Remote RMM-700 Intelligent Site Management Device. Installation Guide WESTELL.COM Remote RMM-700 Intelligent Site Management Device Guide INSTALLATION GUIDE Westell Technologies April 2015 Part # 030-300653 Rev. A Copyright 2015 by Westell, Inc. All Rights Reserved. Westell, Kentrox,

More information

INSTALLATION GUIDE. Remote RMM-800 Intelligent Site Management Device. Installation Guide WESTELL.COM

INSTALLATION GUIDE. Remote RMM-800 Intelligent Site Management Device. Installation Guide WESTELL.COM Remote RMM-800 Intelligent Site Management Device Guide INSTALLATION GUIDE Westell Technologies July 2016 Part # 030-300731 Rev. C Copyright 2016 by Westell, Inc. All Rights Reserved. Westell, Kentrox,

More information

AI130 AIswitch Series 130 Chassis Installation Guide

AI130 AIswitch Series 130 Chassis Installation Guide AI130 AIswitch Series 130 Chassis Installation Guide Part Number QR-130 Rev 3 2007 by Kentrox, Inc. All rights reserved. Copyright 2007 by Kentrox, Inc. All Rights Reserved. The material discussed in this

More information

AI180I AIswitch Series 180 Integrated Chassis Installation Guide

AI180I AIswitch Series 180 Integrated Chassis Installation Guide AI180I AIswitch Series 180 Integrated Chassis Installation Guide Part Number QR-180I Rev 5 2008 by Kentrox, Inc. All rights reserved. Copyright 2008 by Kentrox, Inc. All Rights Reserved. The material discussed

More information

AI port High Speed Asynchronous Line Card Installation Guide

AI port High Speed Asynchronous Line Card Installation Guide AI232 32-port High Speed Asynchronous Line Card Installation Guide Part Number QR-232 Rev 3 2008 by Kentrox, Inc. All rights reserved. Copyright 2008 by Kentrox, Inc. All Rights Reserved. The material

More information

Installing the Cisco AS5400XM Universal Gateway

Installing the Cisco AS5400XM Universal Gateway CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

WIRESPEED ADSL MODEM (MODEL 2000) User Guide WIRESPEED ADSL MODEM (MODEL 2000) User Guide Copyright 2001 Westell, Inc. All rights reserved. 030-300187 Rev. A Printed in the United States of America December 2001 CONTENTS 1. PRODUCT DESCRIPTION...

More information

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

Mercury Helios ASSEMBLY MANUAL & USER GUIDE Mercury Helios ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards NOTE: Boot Camp

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules This document provides the installation and removal instructions for the AC and DC input power supply and fan modules

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions 3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These

More information

Power Supply Installation

Power Supply Installation Power Supply Module Overview, on page Installation Guidelines, on page 4 Installing or Replacing an AC Power Supply, on page 6 Installing a DC Power Supply, on page 7 Finding the Power Supply Module Serial

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis 5910 High Density Lifeline POTS Splitter Installation Instructions Document Number 5910-A2-GZ40-00 May 2005 About the 5910 POTS Splitter The 5910 is a double-density POTS splitter that separates the (Digital

More information

Preparing to Install the Cisco AS5350XM Universal Gateway

Preparing to Install the Cisco AS5350XM Universal Gateway CHAPTER 2 Preparing to Install the Cisco AS5350XM Universal Gateway This chapter describes the tasks you must perform before you begin to install the Cisco AS5350XM universal gateway and includes the following

More information

Perle SMI Media Converter Installation Guide

Perle SMI Media Converter Installation Guide Perle SMI Media Converter Installation Guide P/N 5500316-14 Overview This guide contains instructions necessary for the installation and operation of the Perle SMI Media Converter. This media converter

More information

Installing Power Modules

Installing Power Modules This chapter contains the procedures for installing cards and modules into the chassis after the chassis has been installed into a rack. This chapter also describes how to connect cables to RSP, RP, alarm,

More information

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2

More information

Installing the Cisco 2524 and Cisco 2525 Routers

Installing the Cisco 2524 and Cisco 2525 Routers CHAPTER 3 Installing the Cisco 2524 and Cisco 2525 Routers This chapter guides you through the installation of the Cisco 2524 and Cisco 2525 routers and includes the following sections: Required Tools

More information

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input. LMC5103A-R2 1-slot Multipower Desktop Chassis (Module Not Included) This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining

More information

Enclosure TS-530 User Manual

Enclosure TS-530 User Manual Enclosure TS-530 User Manual 16525 East Laser Drive Fountain Hills, AZ 85268 TEL 480.837.5200 FAX 480.837.5300 info@embeddedx86.com http://www.embeddedx86.com/ Technologic Systems, Inc. COPYRIGHT 1998-200

More information

Installation Manual. Table of Contents

Installation Manual. Table of Contents Table of Contents Table of Contents... 4-1 4.1 Confirming the Installation Preparations... 4-1 4.2 Installation Flowchart... 4-1 4.3 Mounting the Switch to the Designated Position... 4-2 4.3.1 Mounting

More information

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0

More information

4170 POS System Installation Guide

4170 POS System Installation Guide 4170 POS System 4170 Installation Guide Thank you for selecting UTC RETAIL s innovative Model 4170 Point of Sale solution! This Installation Guide will help you efficiently install the 4170 POS. The document

More information

Preparing to Install the VG248

Preparing to Install the VG248 CHAPTER 2 To ensure normal system operation, plan your site configuration and prepare your site before installation. Before installing the VG248, review these sections: Preparing the Installation Site,

More information

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. AREA CODE CHANGE Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. For any Paradyne telephone number that appears in this manual with an 813 area code,

More information

8~14-Port Managed Ethernet Switch

8~14-Port Managed Ethernet Switch 8~14-Port Managed Ethernet Switch Quick Installation Guide Overview The Managed Ethernet Switch solutions are designed for supporting standard industrial applications. Managed switches are easier to prioritize,

More information

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

PIX 515/515E. PIX 515/515E Product Overview CHAPTER CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

G.SHDSL NTU DECEMBER 2006 LB510A

G.SHDSL NTU DECEMBER 2006 LB510A DECEMBER 2006 LB510A G.SHDSL NTU CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500

More information

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT 4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

Dell Networking S4810 Open Networking (ON) Getting Started Guide

Dell Networking S4810 Open Networking (ON) Getting Started Guide Dell Networking S4810 Open Networking (ON) Getting Started Guide Regulatory Model: S4810 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Cisco ONS CL Shelf Assembly Hardware

Cisco ONS CL Shelf Assembly Hardware CHAPTER 1 This chapter provides a description of Cisco ONS 15310-CL shelf hardware. Instructions for installing equipment are provided in the Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.

More information

Installing the Cisco SFS 3504 Server Switch

Installing the Cisco SFS 3504 Server Switch CHAPTER 3 This chapter describes how to mount your Cisco SFS 3504 Server Switch on a rack, boot the Cisco SFS 3504 Server Switch, and configure basic services. For advanced configuration information, see

More information

Storage/Control I/O Module

Storage/Control I/O Module CHAPTER 4 The performs two functions: to connect outside interfaces to the system controller and to house the hard disk drive. It plugs into the back of the VCO/4K system and provides the I/O interfaces

More information

Installing the Cisco MDS 9020 Fabric Switch

Installing the Cisco MDS 9020 Fabric Switch CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet

More information

Connect Router to the Network

Connect Router to the Network Port Connection Guidelines, on page 1 Route Processor Card Overview, on page 2 Install and Remove Transceiver Modules, on page 5 Connect Interface Ports, on page 15 Maintain Transceivers and Optical Cables,

More information

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start ICPDAS FSM-510G Series Ethernet Management Switch Quick Start Version 1.0, Dec 2014 Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com

More information

An ISO-9001 Certified Company

An ISO-9001 Certified Company USER MANUAL MODEL 1002 and 1002S Asynchronous 2-Wire / Coax Short Range Modem An ISO-9001 Certified Company Part #07M1002-C Doc. #050011UC Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT

More information

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Hypercable injecteur HPOE -  Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail : Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

FSM-510G Series Ethernet Management Switch Quick Start Guide

FSM-510G Series Ethernet Management Switch Quick Start Guide FSM-510G Series Ethernet Management Switch Quick Start Guide Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed switches are easily

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

Site Preparation CHAPTER

Site Preparation CHAPTER CHAPTER 3 Site Preparation This chapter describes the steps to take and the considerations you should keep in mind prior to installing the modules in an open rack. It also contains information that applies

More information

Power Supply and Fan Module Installation

Power Supply and Fan Module Installation 3 CHAPTER This chapter describes how to remove and install a new or replacement power supply or fan module in a Catalyst 3750-E or Catalyst 3560-E switch. See these sections: Installation Overview, page

More information

RocketPort Plus Hardware Installation

RocketPort Plus Hardware Installation RocketPort Plus Hardware Installation Introduction This Hardware Installation document discusses the following information: Product overview RocketPort terminology Before installing the hardware Installing

More information

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

1. Carefully unpack the um260 s shipping carton and check the contents for damage. um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing

More information

Installation and Maintenance

Installation and Maintenance CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

Quick Installation Guide 4 Slot Chassis-Based Switch

Quick Installation Guide 4 Slot Chassis-Based Switch Quick Installation Guide 4 Slot Chassis-Based Switch This document will guide you through the basic installation process for your new D-Link chassisbased Switch DGS-6604 Documentation also available on

More information

EP/2 Installation Instructions

EP/2 Installation Instructions 1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in

More information

Installing the Cisco Unified Videoconferencing 3545 MCU

Installing the Cisco Unified Videoconferencing 3545 MCU CHAPTER 2 Installing the Cisco Unified Videoconferencing 3545 MCU The Cisco Unified Videoconferencing 3545 MCU works together with a Cisco Unified Videoconferencing 3545 EMP Enhanced Media Processor (EMP)

More information

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000 INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000 This document describes the basic steps for installing your BV10-100 or BV10-1000. For detailed information about the BV10-100/1000, see the Ethernet Performance

More information

PIX 520. PIX 520 Product Overview CHAPTER

PIX 520. PIX 520 Product Overview CHAPTER CHAPTER 5 PIX 520 This chapter guides you through the installation of the PIX 520, and includes the following sections: PIX 520 Product Overview, page 5-1 Installing the PIX 520, page 5-4 PIX 520 Feature

More information

XBR V4 INSTALLATION AND USER GUIDE

XBR V4 INSTALLATION AND USER GUIDE XBR V4 INSTALLATION AND USER GUIDE xbr V4 Installation and User Guide Page 1 of 18 Revision History Dash#/Rev Date Author Description 0.1 04/03/2013 Eric Anderson Initial draft 0.2 04/08/2013 Eric Anderson

More information

888385_01 Install.book Page 1 Wednesday, November 11, :45 PM. SMDR6 Installation Guide

888385_01 Install.book Page 1 Wednesday, November 11, :45 PM. SMDR6 Installation Guide 888385_01 Install.book Page 1 Wednesday, November 11, 1998 2:45 PM SMDR6 Installation Guide 888385_01 Install.book Page 2 Wednesday, November 11, 1998 2:45 PM 888385_01 Install.book Page i Wednesday, November

More information

PCI Hardware Installation

PCI Hardware Installation PCI Hardware Installation Product Overview The RocketPort PCI series multiport serial card fits into the PCI slot of a personal computer, and uses a 36 MHz processor that is specifically designed to process

More information

Dell Networking C9010 Getting Started Guide

Dell Networking C9010 Getting Started Guide Dell Networking C9010 Getting Started Guide Regulatory Model: C9010 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:

More information

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation Luminato Installation Manual Teleste Corporation Mounting Instructions Mechanical Mounting Luminato Mechanical Installation, agile_59300316, rev0044 Introduction 1 Contents Introduction 4 General... 4

More information

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter Industrial PC IPC191V2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet: http://www.ipcomm.de

More information

Installation Job Aid for Avaya Virtual Services Platform 8400

Installation Job Aid for Avaya Virtual Services Platform 8400 Installation Job Aid for Avaya Virtual Services Platform 8400 Support Release 4.2 NN47227-305 Issue 01.06 June 2015 Go to the Avaya Support website at http://support.avaya.com for the most up-to-date documentation,

More information

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual KIEN2204S Industrial Ethernet Switch Hardware Installation Manual Kyland Technology Co., Ltd. Publication Date: Mar. 2013 Version: V1.0 FAX: +86-10-88796678 Website: http://www.kyland.com E-mail: support@kyland.com

More information

NT1B-300 Rack Installation Instructions

NT1B-300 Rack Installation Instructions The NT1B-300 Rack houses 24 Tone Commander NT1B-300TC ISDN Network Terminations in a 19 rack, 23 rack, or wall mount configuration. The rack is also compatible with Lucent NT1B-300 NT1s. The rack supplies

More information

Install the Cisco ONS CL

Install the Cisco ONS CL 1 CHAPTER This chapter provides procedures for installing the Cisco ONS 15310-CL shelf, cards, and fiber-optic cable. To view a summary of the tools and equipment required for installation, see the Required

More information

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7 D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7 SECTION 4 - FRONT PANEL INDICATORS...8 SECTION 5 - INTERFACE SIGNALS...9 SECTION 6 -

More information

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

9. NTP-C11 Remove and Replace an Ethernet Card, page 1-13 As needed, complete this procedure to remove and replace an ONS CL Ethernet card.

9. NTP-C11 Remove and Replace an Ethernet Card, page 1-13 As needed, complete this procedure to remove and replace an ONS CL Ethernet card. CHAPTER 1 This chapter provides procedures for installing the Cisco ONS 15310-CL shelf, cards, and fiber-optic cable. To view a summary of the tools and equipment required for installation, see the Required

More information

1 Getting Started Installing & Configuring

1 Getting Started Installing & Configuring Before you begin Installation and Setup Instructions for E-Series 60-Drive Trays E760 and E5660 controller-drive trays DE6600 expansion drive trays Unpack & Prepare Install Hardware Connect Drive Trays

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

Follow the procedure below for unpacking the carton in which the device is shipped. DW-GTW-AC-E1060 Four anti-slide bumpers for desktop installation

Follow the procedure below for unpacking the carton in which the device is shipped. DW-GTW-AC-E1060 Four anti-slide bumpers for desktop installation 1 Introduction This document provides a hardware description of the DW-GTW-AC-E1060 (hereafter referred to as device) and step-by-step procedures for mounting and cabling the device. The device supports

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

PIX 535. PIX 535 Product Overview CHAPTER

PIX 535. PIX 535 Product Overview CHAPTER CHAPTER 7 PIX 535 This chapter describes the installation of the PIX 535, and includes the following sections: PIX 535 Product Overview Installing a PIX 535 PIX 535 Feature Licenses Installing Failover

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

Dell Networking S4100-ON Series. Set-Up Guide

Dell Networking S4100-ON Series. Set-Up Guide Dell Networking S4100-ON Series Set-Up Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either

More information

G.SHDSL NTU with Fixed Serial Interfaces

G.SHDSL NTU with Fixed Serial Interfaces DECEMBER 2006 ME231A ME232A ME233A G.SHDSL NTU with Fixed Serial Interfaces CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support,

More information

Perle SMI Media Converter Installation Guide

Perle SMI Media Converter Installation Guide Perle SMI Media Converter Installation Guide P/N 5500316-10 Introduction Perle SMI Media Converters provide seamless high-speed managed integration of Ethernet to Fiber networks. Overview This guide contains

More information

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution! 1170 POS SYSTEM 1170 INSTALLATION GUIDE Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution! This Installation Guide will help you efficiently install the 1170 POS. The document

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

CPCI-PS24 24V-Power Supply

CPCI-PS24 24V-Power Supply 24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72

More information

RS-232 Industrial Media Converter

RS-232 Industrial Media Converter USER GUIDE The leader in rugged fiber optic technology. U-151 2018C-0327 Industrial Media Converter COMPACT, RUGGED & TEMPERATURE HARDENED Introduction This Industrial Serial Data media converter transports

More information

AURA SSD FOR MAC PRO. Installation Guide

AURA SSD FOR MAC PRO. Installation Guide AURA SSD FOR MAC PRO Installation Guide CONTENTS Introduction... 1 1.1 System Requirements 1.2 Package Contents 1.3 About This Manual Installation... 2 2.1 Preparing the Mac Pro 2.2 Installing the Aura

More information

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Trays. Apply Power. Connect Data Hosts. Choose Management Method

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Trays. Apply Power. Connect Data Hosts. Choose Management Method Before you begin Installation and Setup Instructions for E-Series -Drive and 4-Drive Trays E700 and E5600 controller-drive trays DE600 and DE5600 expansion drive trays Unpack & Prepare Install Hardware

More information

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1018 High Speed Short Range Modem w/ Extra Controls Part# 07M1018-B Doc# 013021UB Revised 11/3/95 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION

More information

XBR V3 INSTALLATION AND USER GUIDE Rev 03. xbr V3 Installation and User Guide Page 1 of 14. (preliminary)

XBR V3 INSTALLATION AND USER GUIDE Rev 03. xbr V3 Installation and User Guide Page 1 of 14. (preliminary) XBR V3 INSTALLATION AND USER GUIDE xbr V3 Installation and User Guide Page 1 of 14 Revision History Rev Date Author Description 01 07/03/2012 Eric Anderson Initial release 02 09/25/2012 Eric Anderson Clarification

More information

Installing the Cisco VG224 Voice Gateway

Installing the Cisco VG224 Voice Gateway CHAPTER 3 This chapter contains the procedures for installing your Cisco VG224 voice gateway and consists of the following sections: Safety Recommendations, page 3-2 Site Log, page 3-3 Keeping Track Checklist,

More information