Metasys Integrator United Power Application

Size: px
Start display at page:

Download "Metasys Integrator United Power Application"

Transcription

1 Metasys Connectivity Technical Manual Metasys Integrator Section Application Note Issue Date 0998 APPLICATION NOTE Metasys Integrator United Power Application lntroduction Page 3 Application Details 3 Component Requirements 5 Vendor Contact Information 6 Design Considerations 6 Cable Connections 7 Cable Pinouts 7 Metasys Integrator Setup 9 Point Mapping Table 11 Metasys Network Setup 13 Mapping to a CS Object 13 Custom Integration Johnson Controls, Inc. 1 Code No. LIT

2 2 Metasys Integrator Metasys Integrator United Power Application

3 lntroduction This document explains the Metasys Integrator United Power application. Use this document with the Metasys Integrator Technical Bulletin (LIT ) in the Metasys Connectivity Technical Manual (FAN 629.5), which provides information on installing and commissioning Metasys Integrator. For information on vendor equipment, see United Power documentation (obtainable from United Power representative). Application Details Metasys Integrator allows United Power Corporation equipment to become an integral part of the Metasys and Metasys Companion Networks. Once a United Power Corporation Focus Interface Module (FIM) is connected to a Metasys or Companion Network via the Metasys Integrator, its data is available to the full complement of Metasys Facility Management System (FMS) features, including Change-of-State (COS) monitoring, alarm notification, trend, and totalization. United Power Corporation produces power distribution and monitoring equipment for computer room applications. The Type 1 Focus Interface Module allows the power distribution and monitoring equipment to be monitored at a central location. The FIM was designed to be connected to the United Power Focus Central Monitoring System. This application of Metasys Integrator allows the FIM to become a node on the Metasys Network. The FIMs are networked together via RS-422 and can communicate with Metasys Integrator using an RS-232 to RS-422 converter. Each FIM is connected to the RS-422 network and assigned a unique address between 1 and 126. Since each FIM occupies two addresses (its assigned address for analog points, assigned address + 1 for binary points), the maximum number of FIMs that can be addressed on a Metasys Integrator vendor port is 63. Since RS-422 only supports ten devices without a repeater installed, a repeater is needed to obtain the maximum number of FIMs. Figure 1 shows a sample FIM network configuration. Notice in the figure that the FIM addresses have been assigned to odd numbers only (i.e., 1, 3, etc.). This is because the FIM s digital points are read by a command that has the FIM address + 1. Therefore, no two FIMs on a network should have consecutive addresses. The FIM address is set at the front panel of the FIM. Metasys Integrator Metasys Integrator United Power Application 3

4 N1 LAN Standard NCU RS-232 RS-232 to RS-422 Converter Focus Interface Module 1 UNT Metasys Integrator Focus Interface Module 3 N2 Bus Focus Interface Module 63 Figure 1: United Power Focus Interface Module and Metasys Integration unpwr1 Panel Unit M3 Workstation RS-232 RS-232 to RS-422 Converter Focus Interface Module 1 Metasys Integrator Focus Interface Module 3 UNT N2 Bus Note: A PC version and converter may be substituted for the Panel unit. Focus Interface Module 63 Figure 2: United Power Focus Interface Module and Metasys Companion Integration unpwr2 4 Metasys Integrator Metasys Integrator United Power Application

5 The model 422LPCON RS-232 to RS-422 converter, available from B&B Electronics, has worked well for this application. You also need a 9-pin female to 25-pin female RS-232 cable, and a cable supplied by United Power for connecting to TB11 of the FIM. Configure the cables as shown in Figures 3 and 4. The TB11 and TB12 connectors on the FIM require a special 5-pin connector. The cables needed to daisy chain the FIMs should be ordered directly from United Power. The cable between the FIM and the converter should be have the 5-pin connector on one end (for connecting to the FIM) and no connector on the other end (for connecting to the terminal block on the converter). You may need to use an ohmmeter to identify the wires you connect to the terminal block on the converter. Component Requirements Metasys Release Requirements To integrate United Power FIMs, you need the following: properly installed Focus Interface Modules (Type 1, 2, or 3) RS-232 cable model 422LPCON RS-232 to RS-422 converter and 422PS2 power supply from B&B Electronics Metasys Integrator N2 Bus (for connecting Metasys Integrator to the Metasys or Companion Network) portable Personal Computer (PC) for downloading vendor communication tables (.VCT files) and network setup information, and for running diagnostics cable for connecting portable PC to Metasys Integrator the correct vendor communication table (.VCT file) to download into Metasys Integrator (supplied on diskette) This document describes the RS-232 cable and the vendor communication tables. United Power Corporation documentation describes their equipment. The remaining components are described in the Metasys Integrator Technical Bulletin (LIT ) in the Metasys Connectivity Technical Manual (FAN 629.5). To integrate United Power Corporation equipment into the Metasys Network, you need: Metasys Operator Workstation (OWS) software Release 4.0 or higher Metasys Integrator software/firmware Release 8.0 or higher Metasys Integrator Metasys Integrator United Power Application 5

6 Metasys Companion Release Requirements Vendor Component Requirements Vendor Contact Information To integrate United Power Corporation equipment into the Metasys Companion Network, you need: Metasys Companion Release 4.0 or higher Metasys Integrator software/firmware Release 8.0 or higher Integration between Metasys Integrator and United Power Corporation equipment has been tested with the United Power Corporation Type 1 Focus Interface Module and B&B Electronics 422LPCON RS-232 to RS-422 converter. Changes to this equipment or integration of United Power or B&B Electronics products not discussed in this document will require additional development and testing by Systems Products. For information on integrating other products, refer to the Custom Integration section in this technical bulletin. United Power Corporation 2132 Tommlyn Street (MG) Richmond, VA Phone: FAX: B&B Electronics 707 Dayton Road Ottawa, IL Phone: (815) Design Considerations When integrating United Power equipment, consider the following: Make sure United Power equipment is set up and running properly before integrating with Metasys or Companion. (The United Power representative is responsible for operation of United Power equipment.) The FIM can be programmed from the front panel following instructions provided by United Power. The FIM goes offline during programming. For more information, see the United Power document: Series PDM Power Distribution Module Third Party Communication Interface Software Version p, Document Number PPA R1, 3/20/96. No two FIMs on a network should have consecutive addresses. (The United Power representative is responsible for operation of United Power equipment.) RS-232 cable distance between Metasys Integrator and the converter can be a maximum of 50 feet. 6 Metasys Integrator Metasys Integrator United Power Application

7 Cable Connections Cable Pinouts Use the following cable pinouts for the RS-232 connection between Metasys Integrator and the B&B Electronics RS-232 to RS-422 converter. Vendor Port A or B on Integrator DB-9 Female Signal Pin RD TD GND RTS CTS RS-232 RS-232 Port on Converter DB-25 Female Pin Signal 3 RD 2 TD 7 GND 4 RTS 5 CTS (50 ft. maximum) upcvt Figure 3: Cable Pinouts B&B Electronics Converter Connect the 9-pin end of the RS-232 cable to Vendor Port A or B on Metasys Integrator. Connect the 25-pin end to the RS-232 Port on the converter. Refer to Figure 4 for connections between the converter and the FIMs. RS-232 to RS-422 Converter Model 422LPCON DB-25 Male Pin FR Gnd Shield TD(A) TD(B) RD(A) RD(B) GND +12 VDC RS-422 Focus Interface Module (FIM) TB11 RX- RX+ TX- TX+ TB12 AC Adapter B & B Model 422PS2 To Next FIM upcvt2 Figure 4: Converter to Focus Interface Module (FIM) Cable Pinouts Metasys Integrator Metasys Integrator United Power Application 7

8 8 Metasys Integrator Metasys Integrator United Power Application

9 Metasys Integrator Setup To set up Metasys Integrator, use a portable PC connected to the Metasys Integrator Terminal Port. Metasys Integrator setup involves: downloading the correct vendor communication table (.VCT file) setting up the ports setting up the network addressing The following table provides information specific to United Power. For detailed procedures, see the Metasys Integrator Technical Bulletin (LIT ) in the Metasys Connectivity Technical Manual (FAN 629.5). Table 1: Metasys Integrator Setup for United Power Corporation Focus Interface Module (FIM) Vendor Communication Table (.VCT FILE) United Power Corporation Type 1 Focus Interface Module Port Setup Baud Rate 9600 Word Length 8 Stop Bits 1 Parity Interface Network Setup UP_FIM.VCT None RS-232 Vendor Address 1-126* Timeout Value Poll Delay Performance Guide 550 ms 0 ms Approximate Scan Time 2 seconds (For a single device) * Each device needs two consecutive addresses (i.e., 1 and 2, 3 and 4, 125 and 126). Each N2 address reads data from 2 consecutive device addresses for a single FIM device. Enter the first address (the commissioned address) as the vendor address. Metasys Integrator Metasys Integrator United Power Application 9

10 10 Metasys Integrator Metasys Integrator United Power Application

11 Point Mapping Table The FIM reports the status of 33 analog input points and 9 binary input points. There are no output points. Eight of the binary input points are building contact alarms, which may be set up in the FIM as normally open or normally closed contacts. The FIM reports the open or closed status, not the alarm status of these alarm points. For example, suppose point BI 4 is a normally open alarm point: The point would be in alarm and return a value of 1 to Metasys Integrator whenever the contact was closed. However, suppose the point is a normally closed alarm point: When the contact is closed, a value of 1 is reported to the Metasys Integrator even though the point is not in alarm. When the contact is opened, a value of 0 is reported to Metasys Integrator and the point is in alarm. The ninth alarm point, BI 9, is a summary alarm, which the FIM sets to 1 whenever a point is in alarm. Table 2 shows the points available for mapping in the United Power Corporation FIM. To get the hardware reference for mapping points to a CS object (via the software model), combine the NPT (Network Point Type) and NPA (Network Point Address). For example, the hardware reference for the Phase A Current point is 7. Table 2: United Power Corporation FIM Points NPT 1 NPA 2 Unit Description Volts Volts Volts Volts Volts Volts Amps Amps Amps Amps Amps Hz DegF % RH kva % % % Input Voltage A:B (delta) A:N (wye)* Input Voltage B:C (delta) B:N (wye)* Input Voltage C:A (delta) C:N (wye)* Output Voltage A:B (delta) A:N (wye)* Output Voltage B:C (delta) B:N (wye)* Output Voltage C:A (delta) C:N (wye)* Phase A Current Phase B Current Phase C Current Neutral Current Ground Current Frequency in Hz Temperature Humidity (% RH) Total kva % Load Phase A % Load Phase B % Load Phase C 1 Network Point Type 2 Network Point Address * Description is dependent on whether the unit is set to delta or wye. Continued on next page... Metasys Integrator Metasys Integrator United Power Application 11

12 NPT 1 (Cont.) NPA 2 Unit Description kw kw kw kw kwh kwh kwh kw % % % BI 1 BI 2 BI 3 BI 4 BI 5 BI 6 BI 7 BI 8 BI 9 1 Network Point Type 2 Network Point Address Total kw Phase A kw Phase B kw Phase C kw Phase A Power Factor Phase B Power Factor Phase C Power Factor Phase A kw Hours Phase B kw Hours Phase C kw Hours Peak Demand Phase A Distortion % Phase B Distortion % Phase C Distortion % Sag/Surge/Impulse Event Counter Building Contact 1 (0=Open, 1=Closed) Building Contact 2 (0=Open, 1=Closed) Building Contact 3 (0=Open, 1=Closed) Building Contact 4 (0=Open, 1=Closed) Building Contact 5 (0=Open, 1=Closed) Building Contact 6 (0=Open, 1=Closed) Building Contact 7 (0=Open, 1=Closed) Building Contact 8 (0=Open, 1=Closed) Summary Alarm (0=Inactive, 1=Active) 12 Metasys Integrator Metasys Integrator United Power Application

13 Metasys Network Setup Metasys Network Setup is described in the Metasys Integrator Technical Bulletin (LIT ) in the Metasys Connectivity Technical Manual (FAN 629.5). This section contains details specific to United Power applications. Mapping to a CS Object Table 3: Software Model and CS Object Definition Application Software Model (on Models diskette) Display Attribute (recommended) NT Command Attribute (recommended) United Power Focus Interface Module (FIM) UP_FIM.DDL 12 Frequency 12* * For the NT Command attribute, use the same attribute as the Display attribute. However, since the points are not commandable, you will not be able to command the attribute. (This must be defined because the NT Command attribute cannot be null.) Metasys Integrator Metasys Integrator United Power Application 13

14 14 Metasys Integrator Metasys Integrator United Power Application

15 Custom Integration For information on integrating products which are not discussed in this document, first refer to the Metasys Compatible Global Catalog, an online list of released Connectivity products. If this list does not provide the information you require, consider using the System Integration Project Data Sheet to request a custom contract from the System Integration Team. Both the Metasys Compatible Global Catalog and the System Integration Project Data Sheet can be accessed from The Advisor by performing the following steps: 1. Click on the Products button located on the left side of The Advisor home page. 2. Click on the Product Literature link. 3. Click on the Metasys link. 4. Click on the Sales button. 5. Click on the Connectivity Sales Resource Manual FAN 629 link. 6. Find the System Integration Project Data Sheet link in the table of contents. Click on this link to view an online copy of the System Integration Project Data Sheet, or click on the Metasys Compatible Global Catalog link below it to view a list of released Connectivity products. The System Integration Project Data Sheet (LIT ) can also be found in the Metasys Connectivity Sales Resource Manual (FAN 629). If you need further assistance, contact Johnson Controls Field Support Services. Metasys Integrator Metasys Integrator United Power Application 15

16 Notes Controls Group FAN E. Michigan Street Metasys Connectivity Technical Manual P.O. Box 423 Metasys Integrator Release 8.0 Milwaukee, WI Printed in U.S.A Metasys Integrator Metasys Integrator United Power Application

Metasys Integrator Multistack Application

Metasys Integrator Multistack Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0998 APPLICATION NOTE Metasys Integrator Multistack Application lntroduction Page *3 Application Details

More information

Metasys Integrator GE Lighting Application

Metasys Integrator GE Lighting Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0998 APPLICATION NOTE Metasys Integrator GE Lighting Application lntroduction Page 3 Application Details

More information

Metasys Integrator Allen-Bradley Custom Application

Metasys Integrator Allen-Bradley Custom Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0998 APPLICATION NOTE Metasys Integrator Allen-Bradley Custom Application Introduction Page 3 Application

More information

Metasys Integrator Graham Application

Metasys Integrator Graham Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0496 APPLICATION NOTE Metasys Integrator Graham Application Introduction Page 3 Application Details 3

More information

Metasys Integrator Northern Application

Metasys Integrator Northern Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0900 APPLICATION NOTE Metasys Integrator Northern Application lntroduction Page *3 Application Details

More information

Metasys Integrator Powerware Application (previously the Exide Application)

Metasys Integrator Powerware Application (previously the Exide Application) Application Note Issue Date 11/01/01 APPLICATION NOTE Metasys Integrator Powerware Application (previously the Exide Application) lntroduction Page Application Details Component Requirements 4 Vendor Contact

More information

Metasys Integrator Caterpillar Application

Metasys Integrator Caterpillar Application Application Note Issue Date May, 00 APPLICATION NOTE Metasys Integrator Caterpillar Application Introduction Application Details Component Requirements Vendor Contact Information Design Considerations

More information

Metasys Integrator Cutler-Hammer Application

Metasys Integrator Cutler-Hammer Application Application Note Issue Date May, 00 APPLICATION NOTE Metasys Integrator Cutler-Hammer Application Introduction Application Details Component Requirements 9 Vendor Contact Information Design Considerations

More information

N2 Dialer Module. Features and Benefits

N2 Dialer Module. Features and Benefits Metasys Network Sales Resource Manual 635 Application Specific Controllers Section Product Bulletin Issue Date 1194 N2 Dialer Module The N2 Dialer Module (NDM) provides a low-cost method of connecting

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter ICD105A 1008 page 1/5 7319 r001 ICD105A Industrial RS-232 to RS-422/485 Converter Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

Downloading Metasys Integrator 300 Series Code

Downloading Metasys Integrator 300 Series Code M-Tool Manual 693 System Tools Applications Section Issue Date 0101 APPLICATION NOTE Downloading Metasys Integrator 300 Series Code Downloading Metasys Integrator 300 Series Code...3 Introduction...3 Key

More information

XT-9100 Technical Bulletin

XT-9100 Technical Bulletin System 9100 Technical Manual 636.4 Technical Bulletins Section Technical Bulletin Issue Date 0896 XT-9100 Technical Bulletin XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3 SX

More information

Extended Digital Controller

Extended Digital Controller The Metasys Extended Digital Controller Metasys Network Sales Resource Manual 635 Application Specific Controllers Section Product Bulletin Issue Date 1093 Extended Digital Controller (DX-9100) is the

More information

Parallel to Serial and Serial to Parallel Converter CE Model 232SPS2 Documentation Number 232SPS2-3903m

Parallel to Serial and Serial to Parallel Converter CE Model 232SPS2 Documentation Number 232SPS2-3903m Parallel to Serial and Serial to Parallel Converter CE Model 232SPS2 Documentation Number 232SPS2-3903m This product designed and manufactured in Ottawa, Illinois USA of domestic and imported parts by

More information

Metasys and Companion

Metasys and Companion Metasys Network Technical Manual 636 App. Notes: Operator Devices Section Technical Bulletin Issue Date 0191 Metasys and Companion Application Page 3 Purpose of Application 3 Setting Up the Windows Terminal

More information

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology 485DRCI RS-232 RS-485 2-Wrie RS-422/485 4-Wire RS-232 CON. RS-422/485 CON. Data Rate Isolation Surge Protection Industrial Bus Source Input Voltage Power Consumption Connector p/n 7207r3 485DRCI-4108ds

More information

TC-9102 Terminal Controller

TC-9102 Terminal Controller Metasys Network Sales Resource Manual 635 Application Specific Controllers Section Product Bulletin Issue Date 1095 TC-9102 Terminal Controller The TC-9102 Terminal Controller, the latest addition to the

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.

STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX. STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Package Includes/System Requirements PACKAGE INCLUDES

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

Modular Room Control (MRC) Series Expansion Board

Modular Room Control (MRC) Series Expansion Board Installation Instructions Issue Date December 13, 2002 Modular Room Control (MRC) Series Expansion Board Application The Modular Room Control (MRC) system has the ability to expand its input/output capabilities

More information

Defining Points. Introduction

Defining Points. Introduction M-Series Workstation with Companion/Facilitator Manual 9-1 Chapter 9 Defining Points Introduction This chapter explains how to define software points. Points are software representations of input and output

More information

Industrial Isolated Converters

Industrial Isolated Converters ICD120A ICD140A Product Data Sheet Industrial Isolated Converters ICD120A Features Suitable for use in Class 1, Division 2, Groups A, B, C, and D Hazardous Locations, or Nonhazardous locations only. Easy

More information

Intelligent Devices IDI 1100 Series Technical Manual

Intelligent Devices IDI 1100 Series Technical Manual Intelligent Devices IDI 1100 Series 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights Reserved

More information

Metasys Integrator 300 Series Commissioning

Metasys Integrator 300 Series Commissioning Metasys Connectivity Technical Manual 629.5 Section Technical Bulletin Issue Date 0900 TECHNICAL BULLETIN 300 Series Commissioning 300 Series Commissioning...3 Introduction...3 Key Concepts...5 Related

More information

APPLICATION NOTE. N2 Dial Application. Using N2 Dial...3. Introduction...3. Key Concepts...4

APPLICATION NOTE. N2 Dial Application. Using N2 Dial...3. Introduction...3. Key Concepts...4 FANs 637.5, 1637.5 N2 Dial Section Issue Date 0400 APPLICATION NOTE N2 Dial Application Using N2 Dial...3 Introduction...3 Key Concepts...4 N2 Dial Configuration... 4 Downloading with N2 Dial...*6 Dial-in

More information

ICC. Metasys N2 Master Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

ICC. Metasys N2 Master Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc. INDUSTRIAL CONTROL COMMUNICATIONS, INC. Metasys N2 Master Driver Manual January 5, 2018 2018 Industrial Control Communications, Inc. TABLE OF CONTENTS 1 Metasys N2 Master... 2 1.1 Overview... 2 1.2 Connections...

More information

MultiCube. Modbus Data Tables. August Northern Design (Electronics) Ltd Bradford UK

MultiCube. Modbus Data Tables. August Northern Design (Electronics) Ltd Bradford UK MultiCube Modbus Data Tables August 2005 Modbus Data Tables Northern Design (Electronics) Ltd Bradford UK 1. Introduction This document is intended as a supplement to the MultiCube Modbus Options Installation

More information

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology 485DRCI Industrial RS-232 to RS-422/485 Converter p/n 7207r5 485DRCI-2212ds page 1/5 Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

General Specifications

General Specifications General Specifications GS 48D50Z00-00E-N C0-950-00 Basic Communication System ProSafe-COM A major part of this functionality is mapped upon an industrial PC, thus representing ProSafe- COM. The basic hardware

More information

Integrity Instruments

Integrity Instruments Integrity Instruments P.O. Box 451 Order Phone 800-450-2001 Pine River Minnesota Fax Phone 218-587-3414 56474 USA Tech Phone 218-587-3120 http://www.integrityusa.com 485-25A High Speed RTS Enabled RS-232

More information

Hookingupacomputertothe3-wireSimplicity bus.

Hookingupacomputertothe3-wireSimplicity bus. Simplicity Hookingupacomputertothe3-wireSimplicity bus. Purpose OneofthemajoradvantagesoftheSimplicity control is its ability to be connected to a computer. The computer can be used to modify the control

More information

Lab and Central Plant Controller

Lab and Central Plant Controller Metasys Network Sales Resource Manual 635 Application Specific Controllers Section Product Bulletin Issue Date 0290 Lab and Central Plant Controller The Metasys Lab and Central Plant (LCP) Controller is

More information

ISOLATED RS-232 TO RS-422/485 CONVERTER

ISOLATED RS-232 TO RS-422/485 CONVERTER QUICK START GUIDE ICD400A ISOLATED RS-232 TO RS-422/485 CONVERTER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Specifications Complies with FCC Class B and CE requirements. Withstands

More information

APPLICATION NOTE JC/85

APPLICATION NOTE JC/85 Metasys Network Technical Manual 636 App. Notes: Network Communications Section Application Note Issue Date 0401 APPLICATION NOTE JC/85 Gateway Introduction Page 3 Application Details *3 Hardware and Software

More information

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T PCIe Card Selection Guide PCIe-CAN Card Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T Channels I/O Isolation Voltage Baud Rate Terminator Resistor I/O PIN Type 2 Max. 1 Mbps Jumper for 120

More information

CURRENT PROTECTION RELAY SMPR-1

CURRENT PROTECTION RELAY SMPR-1 CURRENT PROTECTION RELAY SMPR-1 1.- ORION ITALIA SERIES MODBUS PROTOCOL. The ORION ITALIA SERIES implement a subset of the AEG Modicon Modbus serial communication standard. Many devices support this protocol

More information

Metasys N1 Network Integration

Metasys N1 Network Integration Product Bulletin Issue Date March 31, 2003 Metasys N1 Network Integration The Metasys N1 Network Integration solution connects existing Metasys N1 based building automation systems into the new generation

More information

FX Input/Output (I/O) Modules XM07 and XM14

FX Input/Output (I/O) Modules XM07 and XM14 Product Bulletin FX I/O Modules Issue Date July 6, 2009 FX Input/Output (I/O) Modules XM07 and XM14 The FX Input/Output (I/O) Modules provide additional physical input and output points for FX field controllers

More information

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION...9 TECHNICAL DESCRIPTION SPECIFICATIONS... 13

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION...9 TECHNICAL DESCRIPTION SPECIFICATIONS... 13 Contents INTRODUCTION...1 OVERVIEW...1 WHAT S INCLUDED...1 FACTORY DEFAULT SETTINGS...1 CARD SETUP...2 PORT ENABLE / DISABLE...3 IRQ SELECTION...3 INTERFACE SELECTION...4 E2 JUMPER SETTINGS...4 E1 Jumper

More information

ADR7700. RS232 / Data Acquisition Interface USER MANUAL V 1.0

ADR7700. RS232 / Data Acquisition Interface USER MANUAL V 1.0 ADR7700 RS232 / Data Acquisition Interface USER MANUAL V 1.0 Caution: The ADR7700 is a static sensitive device. Observe proper procedures for handling static sensitive devices. ONTRAK CONTROL SYSTEMS INC.

More information

URC Utility Relay Company

URC Utility Relay Company communications i-comm modbus / rs-485 AC-PRO Communicating Trip Units instruction manual ZERO-Hertz Communicating Trip Units URC Utility Relay Company Chagrin Falls, OH 44023 Phone: 888.289.2864 www.utilityrelay.com

More information

MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION

MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION ICP PANEL-TEC MICROBRIDGE INSTALLATION AND OPERATION GUIDE MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION Revision History Revision Date Author Comments 000 3 May 2010 David Walker Initial release.

More information

Installing the DX LCD Display

Installing the DX LCD Display DX LCD Display User s Guide 3-1 Chapter 3 Installing the DX LCD Display Introduction Use the DX LCD Display as either a portable device, or permanently mount it in a panel or on the wall. For panel and

More information

SeaLINK+8/USB. Sealevel Systems, Inc P.O. Box 830 Liberty, SC USA. Phone: (864) FAX: (864)

SeaLINK+8/USB. Sealevel Systems, Inc P.O. Box 830 Liberty, SC USA. Phone: (864) FAX: (864) TM SeaLINK+8/USB Part # 280X Sealevel Systems, Inc P.O. Box 830 Liberty, SC 29657 USA Phone: (864) 843-4343 FAX: (864) 843-3067 www.sealevel.com Contents INTRODUCTION... 1 INSTALLATION INSTRUCTIONS...

More information

SeaLINK+8/USB. Sealevel Systems, Inc 155 Technology Place P.O. Box 830 Liberty, SC USA

SeaLINK+8/USB. Sealevel Systems, Inc 155 Technology Place P.O. Box 830 Liberty, SC USA TM SeaLINK+8/USB Part # 280X Sealevel Systems, Inc 155 Technology Place P.O. Box 830 Liberty, SC 29657 USA Phone: (864) 843-4343 FAX: (864) 843-3067 www.sealevel.com Contents INTRODUCTION... 1 OVERVIEW...1

More information

Introduction to the N30 Supervisory Controller

Introduction to the N30 Supervisory Controller N30 Supervisory Controller User s Manual 2-1 Chapter 2 Introduction to the N30 Supervisory Controller Introduction This chapter describes the basic functions and operation of an N30 Supervisory Controller

More information

Sender Receiver Sender

Sender Receiver Sender EEE 410 Microprocessors I Spring 04/05 Lecture Notes # 19 Outline of the Lecture Interfacing the Serial Port Basics of Serial Communication Asynchronous Data Communication and Data Framing RS232 and other

More information

Introduction to DX LCD Display

Introduction to DX LCD Display DX LCD Display User s Guide 2-1 Chapter 2 Introduction to DX LCD Display Introduction The DX LCD Display unit is a person/controller interface used with the DX-9100 series of controllers. The display can

More information

RC1170-RC232 USER MANUAL

RC1170-RC232 USER MANUAL RC1170-RC232 USER MANUAL Overview: Introducing RC11XX-RC232 RF Transceiver boards for the data transmission using RF. Where RC11xx transceiver modules are compact surface-mounted high performance modules

More information

M-Bus Central Unit. Use

M-Bus Central Unit. Use 6 M-Bus Central Unit OZW The M-bus central unit is used for the remote readout, remote operation and supervision of an M-bus plant with a maximum of consumption meters and controllers featuring an M-bus

More information

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications Multilin EPM 6100 Energy and Demand Submeter with Wi-Fi The EPM 6100 is a powerful tool that allows customers to monitor and manage their energy usage within factories, businesses and across campuses.

More information

Operating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World!

Operating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World! Operating Bulletin Model BB3-232 and BB3-I-232 USB Multi-Drop Box The Fastest Flow Controller Company in the World! 1 10/16/2017 Rev.1 DOC-BB3232MAN 2 Introduction Alicat BB3-232 Multi-Drop Box Operating

More information

RS-232/422/485 Serial Card

RS-232/422/485 Serial Card Optically Isolated Single Port PCI Bus CE RS-232/422/485 Serial Card with Send Data Control MODELS: 3PCIOSD1A 3PCIOSD1B Documentation Number 3PCIOSD1x-3903m (pn4649-r004) This manual applies to models

More information

MicroTech Series-100 Application Specific Controller

MicroTech Series-100 Application Specific Controller Installation & Maintenance Data IM 657-1 Group: Controls Part Number: 594861Y Date: March 1998 MicroTech Series-100 Application Specific Controller a0196 1998 McQuay International Contents Contents...2

More information

MODBUS/TCP TO SIEMENS G110/G120/MM440 APPLICATION

MODBUS/TCP TO SIEMENS G110/G120/MM440 APPLICATION ICP PANEL-TEC MICROBRIDGE INSTALLATION AND OPERATION GUIDE MODBUS/TCP TO SIEMENS G110/G120/MM440 APPLICATION Revision History Revision Date Author Comments 000 02 June 2009 David Walker Initial release.

More information

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES 1. Introduction Real time monitoring and control is necessary to ensure public and employee safety and to protect the integrity

More information

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems. IntesisBox Server - M-Bus (EN 13757-3) Gateway for the integration of M-BUS meters with and based control systems. Integrate M-Bus meters into your master device or system (BMS, SCADA, PLC, HMI, TouchPanels

More information

Polling the N2 Network or Zone Bus for Devices

Polling the N2 Network or Zone Bus for Devices Metasys Checkout Tool User s Guide 3-1 Chapter 3 Polling the N2 Network or Zone Bus for Devices Introduction The first step in the checkout process is using the Metasys Checkout Tool to find and display

More information

COMM+422.PCI USER MANUAL

COMM+422.PCI USER MANUAL TM COMM+422.PCI USER MANUAL Part # 7404 Sealevel Systems, Inc P.O. Box 830 Liberty, SC 29657 USA Phone: (864) 843-4343 FAX: (864) 843-3067 www.sealevel.com Contents INTRODUCTION... 1 OVERVIEW...1 WHAT

More information

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function Appendix A Specifications This appendix lists the specifications for the BANDIT family of products. Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200

More information

COMM+8.LPCI Users Manual Part Number 7803

COMM+8.LPCI Users Manual Part Number 7803 COMM+8.LPCI Users Manual Part Number 7803 Sealevel Systems, Inc. Telephone: 864.843.4343 PO Box 830 Fax: 864.843.3067 Liberty, SC 29657 USA www.sealevel.com Contents INTRODUCTION... 1 OVERVIEW... 1 WHAT

More information

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN. The 12.5kW power shelf accepts 3-phase input power and provides stable DC output power (1000A at 12.5VDC). The OCP 21-inch power shelf includes a total of 5+5 high-power, hot-swappable PSUs in redundant

More information

TECHNICAL BULLETIN. Using M-Authorize. Using M-Authorize...2. Introduction Key Concepts... 3

TECHNICAL BULLETIN. Using M-Authorize. Using M-Authorize...2. Introduction Key Concepts... 3 Issue Date May 31, 2002 TECHNICAL BULLETIN Using M-Authorize Using M-Authorize...2 Introduction... 2 Key Concepts... 3 Software Authorization... 3 Johnson Controls Software Authorization Form... 3 Detailed

More information

RTU560 Connections and Settings DIN Rail RTU 560CIG10

RTU560 Connections and Settings DIN Rail RTU 560CIG10 Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail

More information

Intelligent Devices IDI 6005 Speed Sign Controller Technical Manual

Intelligent Devices IDI 6005 Speed Sign Controller Technical Manual Intelligent Devices IDI 6005 Speed Sign Controller 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights

More information

Sauter Systems

Sauter Systems 96.692/1 EYZ 292:, interface The is a interface for connecting the CASE Suite/ programming tools and the various novapro software on the management level to the EY3600 system with in a local area network

More information

MED102A. Industrial Serial to Single-mode Fiber Converter

MED102A. Industrial Serial to Single-mode Fiber Converter MED102A - 0708 pg. 1 / 5 MED102A Industrial Serial to Single-mode Fiber Converter Data Rates up to 115.2 kbps 9 Mile (15 km) Range 10 to 48 VDC Input Voltage Wide Operating Temperature 2000V Isolation

More information

7I74 MANUAL 8 CHANNEL RS-422 INTERFACE

7I74 MANUAL 8 CHANNEL RS-422 INTERFACE 7I74 MANUAL 8 CHANNEL RS-422 INTERFACE V1.2 This page intentionally almost blank Table of Contents GENERAL.......................................................... 1 DESCRIPTION.................................................

More information

Installing the Panel. Installing the Panel

Installing the Panel. Installing the Panel 7 In this section you will be given all of the information you need to install the panel. Before actually installing the OP- panel, it may be helpful to examine the specifications and make sure that the

More information

ICP PANEL-TEC PEX3000 II

ICP PANEL-TEC PEX3000 II ICP PANEL-TEC PEX3000 II MODBUS PORT EXPANDER INSTALLATION AND OPERATION GUIDE REVISION HISTORY Revision Date Author Comments 000 29 Aug 2008 Keira Majors Initial release. 001 16 Sep 2008 David Walker

More information

SeaLINK+232I USER MANUALM

SeaLINK+232I USER MANUALM SeaLINK+232I USER MANUALM TM Part # 2103 Sealevel Systems, Inc. Phone: (864) 843-4343 PO Box 830 Fax: (864) 843-3067 Liberty, SC 29657 USA www.sealevel.com Contents INTRODUCTION... 1 INSTALLATION INSTRUCTIONS...

More information

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual ADAM-510 RS-/RS-85 Repeater ADAM-510S Isolated RS-/85 Repeater ADAM-50 Isolated RS-/85 Converter Startup Manual Packing List Before you begin installing your module, please make sure that the following

More information

NDM Configurator. Introduction Page *3. Configuration Files 5. Downloading 17 APPLICATION NOTE

NDM Configurator. Introduction Page *3. Configuration Files 5. Downloading 17 APPLICATION NOTE System 9100 Technical Manual 636.4 Network Communications Section Application Note Issue Date 0896 APPLICATION NOTE NDM Configurator Introduction Page *3 Configuration Files 5 Hardware Requirements *5

More information

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

AcquiSuite Ally 48 Advanced Branch Circuit Monitor AcquiSuite Ally 48 Advanced Branch Circuit Monitor AMC48-MD AMC48-ED Split Core CT Split Core CT Ally Rogowski Rope CT DESCRIPTION The AcquiSuite Ally 48 is the perfect companion to the data acquisition

More information

Miniature Asynchronous 4-Wire High Speed Modems

Miniature Asynchronous 4-Wire High Speed Modems ME1862A-F ME1863A-F JULY 2003 ME1862A-M ME1863A-M Miniature Asynchronous 4-Wire High Speed Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)

More information

Lumio Release Note Lumio Multi-Touch Communication Protocol

Lumio Release Note Lumio Multi-Touch Communication Protocol Lumio Release Note Lumio Multi-Touch Communication Protocol Note Number RN00009 - Revision A0 Release Date Product Lumio Crystal Touch PCB Controller Abstract This note describes the Lumio Multi Touch

More information

MODEL SELECTION PDM SERIAL COMM. 3 RS-485 *3. External RS-232C to USB adapter

MODEL SELECTION PDM SERIAL COMM. 3 RS-485 *3. External RS-232C to USB adapter POWER DISPLAY METER DESCRIPTION The Model PDM power display meter measures and displays voltage, current, power and energy parameters for single-phase or three-phase systems. Voltages up to 600Vac and

More information

Appendix A Cable Pinouts

Appendix A Cable Pinouts Appendix A Cable Pinouts This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module 163 CT1 and CE1 I/O Modules

More information

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4 TRP-C08 USB to RS232/422/485 Isolated Converter User s Manual Printed Sep.2014 Rev 1.4 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351

More information

INTERFACES TRADITIONAL PC ADAPTER CARD. DATA SHEET page 1/6. Description

INTERFACES TRADITIONAL PC ADAPTER CARD. DATA SHEET page 1/6. Description INTERFACES DATA SHEET page 1/6 Part Number Description AC24AT ISA Bus Serial Port RS422/485, Isolated Description The AC24AT is an RS-422/485 adapter card that plugs directly into the IBM PC bus and provides

More information

International Headquarters. European Headquarters

International Headquarters. European Headquarters VLINX VESP211 SERIAL SERVER Document Name: VESP211_R002_0613 Revision: 2.0 -- February 2013 This product designed and manufactured in Ottawa, Illinois USA using domestic and imported parts by International

More information

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication. 3-3 Wiring NQ-Series models have, besides one power connector, a number of communication ports. Please refer to Table 2.2: Common specifications for NQ-Series and Table 2.3: Specifications per NQ-Series

More information

Bulletin 2707 DTAM Plus Operator Interface Product Data

Bulletin 2707 DTAM Plus Operator Interface Product Data A B Product Data Overview The DTAM Plus devices offer a highly functional operator interface to both Allen-Bradley PLC and SLC processors. This proven interface provides operators with the convenience

More information

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

Vorne Industries. Model 77/232 Serial Input Numeric 3 Display User's Manual Vorne Industries Model 77/232 Serial Input Numeric 3" Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 Page 2 Model 77/232 Serial Input Numeric 3"

More information

Miniature Asynchronous Modems

Miniature Asynchronous Modems ME615A MARCH 2007 ME615AE ME616A ME616AE Miniature Asynchronous Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual USB to RS-232/RS422/485 US-101-I USB To Serial Operation Manual First Edition, Jun 2008 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel Views Description

More information

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds MESR424 4-Port Industrial Modbus Gateway MESR424_r000_2913ds Ethernet-Enable Modbus RS-232/422/485 MODBUS TCP, ASCII & RTU Modbus Flexibility Serial & Ethernet, Masters & Slaves Modbus Messaging Priority

More information

ULTRA 485 USER MANUAL

ULTRA 485 USER MANUAL ULTRA 485 USER MANUAL Part #3055 Sealevel Systems, Inc. Telephone: (864) 843-4343 PO Box 830 Fax: (864) 843-3067 Liberty, SC 29657 USA www.sealevel.com Contents INTRODUCTION... 1 OVERVIEW...1 WHAT S INCLUDED...1

More information

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION TECHNICAL DESCRIPTION SPECIFICATIONS... 14

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION TECHNICAL DESCRIPTION SPECIFICATIONS... 14 Contents INTRODUCTION...1 OVERVIEW...1 WHAT S INCLUDED...1 FACTORY DEFAULT SETTINGS...1 CARD SETUP...2 ADDRESS SELECTION...2 IRQ SELECTION...3 INTERRUPT MODES...4 RS-485 ENABLE MODES...5 CONNECTOR PIN

More information

Cable Pinouts. SRP I/O Module

Cable Pinouts. SRP I/O Module Cable Pinouts A This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module A-1 CT1 and CE1 I/O Modules A-4

More information

Select a Data Communication Interface

Select a Data Communication Interface Printer Setup and Operation Select a Data Communication Interface Select a Data Communication Interface You may connect your print engine to a computer using one or more of the available connections. The

More information

BOARD LEVEL PRODUCTS GPIB<->RS-422/RS-485 INTERFACE BOARD

BOARD LEVEL PRODUCTS GPIB<->RS-422/RS-485 INTERFACE BOARD BOARD LEVEL PRODUCTS RS-422/ INTERFACE BOARD DESCRIPTION The Model Serial Interface is a small, low cost interface board that interfaces serial devices with RS-422 or signals to the bus. The provides

More information

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points) Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE

More information

PAC BI-DP BIM and 8701-CA-BI Carrier

PAC BI-DP BIM and 8701-CA-BI Carrier June 2013 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier PROFIBUS DP Bus Interface Module and Carrier The 8507-BI-DP Bus Interface Module (BIM) provides the communications link between the PAC8000 series

More information

PCI Express 16-Port Serial I/O Cards

PCI Express 16-Port Serial I/O Cards PCI Express 16-Port Serial I/O Cards The PCIe-1600 PCI Express 16-port serial I/O card is a plug & play high-speed serial I/O expansion card for PCI Express bus. Connecting to a PCI Express bus on your

More information

CBL Starter Cable Kit for DuraNAV System

CBL Starter Cable Kit for DuraNAV System Technical Datasheet Td0008 CBL-1010-00 Starter Cable Kit for DuraNAV System Overview The CBL-1010-00 Cable Kit is designed to allow users of the DuraNAV to rapidly start developing and testing software,

More information

LN Series Input/Output (I/O) Extension Modules and LN Communicating Sensors Subnetwork for LN-VAVCF-12 and LN-PRGxxx-12 Application Note

LN Series Input/Output (I/O) Extension Modules and LN Communicating Sensors Subnetwork for LN-VAVCF-12 and LN-PRGxxx-12 Application Note LN Series Input/Output (I/O) Extension Modules and LN Communicating Sensors Subnetwork for LN-VAVCF-12 and LN-PRGxxx-12 Application Note LN-IOE400-0, LN-IOE410-0, LN-IOE420-0, LN-VAVCF-12, LN-PRGxxx-12

More information