The True Capacity of Ecodan
|
|
- Tamsyn Simmons
- 5 years ago
- Views:
Transcription
1
2 The True Capacity of Ecodan
3 The Capacity Problem: Most conventional inverter driven heat pumps suffer from A DECREASE IN HEATING CAPACITY AT LOW AMBIENT TEMPERATURES 7ºC 2ºC -2ºC -7ºC
4 The Capacity Solution: ZUBADAN TECHNOLOGY Mitsubishi Electric s patented Zubadan Technology features a unique Flash Injection Circuit and Hyper Heating Capacity to MAINTAIN HEATING CAPACITY DOWN TO -7ºC
5 The Capacity Solution: ZUBADAN TECHNOLOGY THE FLASH INJECTION CIRCUIT increases the amount of refrigerant which boosts heating capacity at low ambient temperatures. This raises flow temperature and also improves defrost operation.
6 Maintains heating capacity down to Guaranteed heating operation extended to Faster Defrost Operation & improved room temperature stability
7 2ºC -2ºC Despite offering larger capacity models, other manufacturers FAIL to maintain their heating capacities, suffering significant drop off at low ambient temperatures. -7ºC
8 18kW UK Only PUHZ-HW140VHA2 12kW 10kW 12ºC 7ºC 2ºC -2ºC -7ºC Competitor product models are considered to be an alternative for an equivalent application and include: Daikin Altherma EBLQ016BB6V3, Samsung EHS AE160JXYDEH/EU, Vaillant arotherm VWL155/2, Panasonic Aquarea Hi-Efficiency WH-MDC16G6E5 & Hitachi Yutaki-M RASM-6VNE. Capacity data has been rated at low water flow temperatures (35 C) and sourced from market available information, as published online at 20/04/2018. Data for each models assumes peak capacity; however, if the data referenced refers to integrated values (including a defrost cycle), then the expectation is that the rated capacity would be greater than the capacities presented in this document.
9 18kW UK Only PUHZ-HW140VHA2 12kW 10kW DAIKIN Altherma (EBLQ016BB6V3) 12ºC 7ºC 2ºC -2ºC -7ºC Competitor product models are considered to be an alternative for an equivalent application and include: Daikin Altherma EBLQ016BB6V3, Samsung EHS AE160JXYDEH/EU, Vaillant arotherm VWL155/2, Panasonic Aquarea Hi-Efficiency WH-MDC16G6E5 & Hitachi Yutaki-M RASM-6VNE. Capacity data has been rated at low water flow temperatures (35 C) and sourced from market available information, as published online at 20/04/2018. Data for each models assumes peak capacity; however, if the data referenced refers to integrated values (including a defrost cycle), then the expectation is that the rated capacity would be greater than the capacities presented in this document.
10 18kW UK Only PUHZ-HW140VHA2 12kW SAMSUNG EHS (AE160JXYDEH/EU) 10kW 12ºC 7ºC 2ºC -2ºC -7ºC Competitor product models are considered to be an alternative for an equivalent application and include: Daikin Altherma EBLQ016BB6V3, Samsung EHS AE160JXYDEH/EU, Vaillant arotherm VWL155/2, Panasonic Aquarea Hi-Efficiency WH-MDC16G6E5 & Hitachi Yutaki-M RASM-6VNE. Capacity data has been rated at low water flow temperatures (35 C) and sourced from market available information, as published online at 20/04/2018. Data for each models assumes peak capacity; however, if the data referenced refers to integrated values (including a defrost cycle), then the expectation is that the rated capacity would be greater than the capacities presented in this document.
11 18kW UK Only PUHZ-HW140VHA2 12kW 10kW (-3ºC) VAILLANT 15kW arotherm (VWL155/2 A) 12ºC 7ºC 2ºC -2ºC -7ºC Competitor product models are considered to be an alternative for an equivalent application and include: Daikin Altherma EBLQ016BB6V3, Samsung EHS AE160JXYDEH/EU, Vaillant arotherm VWL155/2, Panasonic Aquarea Hi-Efficiency WH-MDC16G6E5 & Hitachi Yutaki-M RASM-6VNE. Capacity data has been rated at low water flow temperatures (35 C) and sourced from market available information, as published online at 20/04/2018. Data for each models assumes peak capacity; however, if the data referenced refers to integrated values (including a defrost cycle), then the expectation is that the rated capacity would be greater than the capacities presented in this document.
12 18kW UK Only PUHZ-HW140VHA2 12kW 10kW PANASONIC Aquarea Hi-Eff (WH-MDC16G6E5) 12ºC 7ºC 2ºC -2ºC -7ºC Competitor product models are considered to be an alternative for an equivalent application and include: Daikin Altherma EBLQ016BB6V3, Samsung EHS AE160JXYDEH/EU, Vaillant arotherm VWL155/2, Panasonic Aquarea Hi-Efficiency WH-MDC16G6E5 & Hitachi Yutaki-M RASM-6VNE. Capacity data has been rated at low water flow temperatures (35 C) and sourced from market available information, as published online at 20/04/2018. Data for each models assumes peak capacity; however, if the data referenced refers to integrated values (including a defrost cycle), then the expectation is that the rated capacity would be greater than the capacities presented in this document.
13 18kW UK Only PUHZ-HW140VHA2 12kW HITACHI Yutaki-M (RASM-6VNE) 10kW 12ºC 7ºC 2ºC -2ºC -7ºC Competitor product models are considered to be an alternative for an equivalent application and include: Daikin Altherma EBLQ016BB6V3, Samsung EHS AE160JXYDEH/EU, Vaillant arotherm VWL155/2, Panasonic Aquarea Hi-Efficiency WH-MDC16G6E5 & Hitachi Yutaki-M RASM-6VNE. Capacity data has been rated at low water flow temperatures (35 C) and sourced from market available information, as published online at 20/04/2018. Data for each models assumes peak capacity; however, if the data referenced refers to integrated values (including a defrost cycle), then the expectation is that the rated capacity would be greater than the capacities presented in this document.
14 PUHZ-HW140VHA2 Altherma (EBLQ016BB6V3) EHS (AE160JXYDEH/EU) arotherm (VWL155/2 A) Aquarea Hi-Eff (WH-MDC16G6E5) HITACHI Yutaki-M (RASM-6VNE) Competitor product models are considered to be an alternative for an equivalent application and include: Daikin Altherma EBLQ016BB6V3, Samsung EHS AE160JXYDEH/EU, Vaillant arotherm VWL155/2, Panasonic Aquarea Hi-Efficiency WH-MDC16G6E5 & Hitachi Yutaki-M RASM-6VNE. Capacity data has been rated at low water flow temperatures (35 C) and sourced from market available information, as published online at 20/04/2018. Data for each models assumes peak capacity; however, if the data referenced refers to integrated values (including a defrost cycle), then the expectation is that the rated capacity would be greater than the capacities presented in this document.
15 The complete range of Ecodan heating products has received full accreditation for the Government's Microgeneration Certification Scheme and as such when installed by an MCS approved installer is a requirement to apply for the Renewable Heat Incentive (RHI). Maintains heating capacityacity down to The Energy Related Products Directive (ErP) Ecodan is compliant with ErP which is a key part of the European Union's drive to encourage businesses and consumers to use more energy efficient products. The Ecodan heat pump range has an energy label of A++
16 Delivering true capacity and constant comfort, the Ecodan Ecodan Heat Pump with Zubadan Technology is the reliable choice for larger applications, whatever the weather! heating.mitsubishielectric.co.uk
Energy-efficient heating, ventilation and air-conditioning Technologies for certified buildings
Otto Oberhumer Senior Corporate Advisor DAIKIN AIRCONDITIONING CENTRAL EUROPE Energy-efficient heating, ventilation and air-conditioning Technologies for certified buildings Energieeffizientes Heizen,
More informationIntesisBox PA-AW-MBS-1 v.2.0
IntesisBox PA-AW-MBS-1 v.2.0 Modbus RTU (EIA485) Interface for Panasonic Aquarea series. User Manual Issue Date: 08/2014 r2.0 Order Code: PA-AW-MBS-1: Modbus RTU Interface for Panasonic Aquarea series
More informationHigh Efficient Data Center Cooling
Nordborg High Efficient Data Center Cooling Copenhagen Center on Energy Efficiency webinar 12. July 2017 Jörg Saar, Danfoss Cooling 1 Danfoss Cooling Contents 1. Short intro to Danfoss Cooling 2. Introduction
More informationAPPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance
APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS Capacity from 600 to 2,010kWr Engineered for flexibility and performance PRODUCT LEAFLET THE AWS SERIES OFFERS TOP EFFICIENCY, LOW SOUND LEVELS AND FLEXIBLE
More informationEvaporative free air cooling technology Providing evaporative free air cooling solutions.
Evaporative free air cooling technology Providing evaporative free air cooling solutions. Creating an effective workspace environment data centre free air cooling technology FreeCool - Evaporative Free
More informationFREEING HPC FROM THE DATACENTRE
FREEING HPC FROM THE DATACENTRE ku:l sistem TM COOLING REDEFINED www.iceotope.com ku:l sistem removes the need for inefficient air cooling technologies FREEING HPC FROM THE DATACENTRE Iceotope s patented
More informationVARIABLE REFRIGERANT FLOW SYSTEMS HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL
HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL Expanding the possibilities STATE-OF-THE-ART DESIGN TAKES PERFORMANCE TO NEW LEVELS Our re-engineered Outdoor Units boast an extended operating
More informationYutaki air source heat pumps Product Training & Installer Programme
Yutaki air source heat pumps Product Training & Installer Programme Smart training solutions, naturally Hitachi Air Conditioning Europe SAS (Hitachi) runs one-day, product specific training courses from
More informationIntroducing the first PATENT PENDING solid state selfregulating
Introducing the first PATENT PENDING solid state selfregulating THERMOELECTRIC GENERATOR. Covered by 4 Patent applications. This novel thermoelectric TEG system will provide continuous power as long as
More informationApplication of Green Technology For Data Centre
Application of Green Technology For Data Centre Steven So Vice President Data Centre Business Cloud Business Division NTT Com Asia Limited 25 Sep 2013 Today s Agenda Why? How? What? Business Drivers
More informationGVS K-BUS R KNX/EIB Push Button Sensor Contents 1. Summary
Guangzhou Video-star Electronics Industrial Co., Ltd K-BUS R Push Button Sensor User manual-ver. 1.1 CHKP-01/01.1.xx CHKP-02/01.1.xx CHKP-03/01.1.xx KNX/EIB Intelligent Installation Systems GVS K-BUS R
More informationDATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency
DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency September 27 th, 2013 Tejas Desai, PE CEM CEA LEED AP Sameer Behere, PE CEM LEED AP Agenda Problem: Quick fixes can
More informationIntesisBox HI-AW-KNX-1
IntesisBox HI-AW-KNX-1 User s Manual Issue date: 02/2017 r2 eng Intesis Software S.L.U. 2017 All Rights Reserved. Information in this document is subject to change without prior notice. The software described
More informationProduct Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres
Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how
More informationOperation 6035 ENGLISH PROG MENU
Operation 6035 PROG MENU ENGLISH Operation 6035 Program button Time of day Day Time Slot Current Room Temperature Target Temperature Menu button PROG MENU FAN AUTO ON COOL OFF HEAT Fan Switch Touch Screen
More informationNoise fi lter for various drive circuitry requiring high temp. operation and peak current handling capability Boost-Converter, Buck-Converter DC/DC
Power Choke Coil for utomotive application Series: PCC-M128MF (MC) High heat resistance and high reliability Using metal composite core (MC) Industrial Property : patents 3 (Registered 1/Pending 2) Features
More informationDUCTED SPLIT SYSTEMS With Scroll compressors
DUCTED SPLIT SYSTEMS With Scroll compressors 2 Benefits TOTAL COMFORT ON WIDE AREAS The Ducted Blower Split Systems for light commercial applications of DXDXT-M/K series are the ideal solution for keeping
More informationMicrogeneration Certification Scheme: MCS 004
Microgeneration Certification Scheme: MCS 004 Product Certification Scheme Requirements: Solar Collectors Issue 3.1 This Microgeneration Product Certification Standard is the property of Department of
More informationExcool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling
Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling Data Centre Solutions Expertly Engineered Indirect Adiabatic and Evaporative
More informationEfficiency of Data Center cooling
Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and
More informationCURRENT TO PROFIBUS PA CONVERTER
PROFIBUS PA преобразователь тока в Profibus www.esma-rt.ru IF303 CURRENT TO PROFIBUS PA CONVERTER Features 0.03% accuracy. Three 4-20 ma input channels. Configuration and Parameterization all through configuring
More informationHow to Improve Energy Efficiency & Reduce Maintenance
How to Improve Energy Efficiency & Reduce Maintenance Getting the most from your energy management system John Wallace Emerson Climate Technologies Retail Solutions Discussion Topics Introduction to an
More informationPCM SLK- Series Inverter Specification
PCM SLK- Series Inverter Specification Page 1 of 7 General Specification Introduction Environment The inverters are designed to be outdoor types. Models In field applications, the power demands from 1.5kW
More informationWHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net
Digi-RTU WHAT IS THE DIGI-RTU The Digi-RTU is a Heating, Ventilation, and Air Conditioning (HVAC) rooftop unit control kit that is both a demand management and energy usage device. It is designed to improve
More informationDEDICATED HEAT RECOVERY UNIT (DHRC)
DEDICATED HEAT RECOVERY UNIT (DHRC) AHRI CERTIFICATION Air-Conditioning, Heating, and Refrigeration Institute Multistack is AHRI Certified and continues to certify products as they are developed AHRI Certification
More informationLarge Tonnage Chillers. Kingsley Hu Technical Support Engineer
Large Tonnage Chillers Kingsley Hu Technical Support Engineer Chongqing Plant Chiller Products Reference Projects Manufacturing Facility Major Milestones Global R&D Talent Production Line introduction
More informationApplication Note: Savant System Integration
Application Note: Savant System Integration This application note describes how to integrate a Savant system with North. Please read the Commander Manual or ObSys Manual alongside this document, available
More informationDigital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect
Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect of Record: SPARCH Project Overview The project is located
More informationRTD-W Installation Instructions
RTD-W Installation Instructions 0V +V POWER 15-24VDC 0V S1 S2 S3 0V S4 S5 S6 English RTD-W Installation Instructions 100.00 RTD-W Control Interface realtime Control Systems 24VAC/30VDC, 1A REMC P1 P2 RS485
More informationHitachi s experience in developing Smart Grids Shin-ichi INAGE Renewable Energy & Smart Grid Division, Hitachi Ltd.
Hitachi s experience in developing Smart Grids Shin-ichi INAGE Renewable Energy & Smart Grid Division, Hitachi Ltd. 1 Copyright 2009, Hitachi, Ltd., All rights reserved. 1 Required Technologies for Smart
More informationMicrogeneration Installation Standard: MCS
Microgeneration Installation Standard: MCS 001-02 MCS Contractor Certification Scheme Requirements Part 2: The Certification Process Issue 3.1 This Microgeneration Installation Standard is the property
More informationInstallation Guide V1.2
+ Welcome to the Connected Home Installation Guide V1.2 MyAir Installation Guide Contents 1 - SYSTEM OVERVIEW 2 - OVERVIEW 3 - COMPATIBILITY 4 - SETUP 5 - DAIKIN ( DK) SETUP 6 - FUJITSU ( FJ) SETUP 7
More information1/28/2013. ASHRAE Standard ASHRAE Standard Aiming at 50% Energy Savings For ASHRAE Standard 90.
-203-203 Stephen V. Skalko, P.E. Chair SSPC 90. Aiming at 50% Energy Savings For 90.-203 ASHRAE Winter Meeting January 28, 203 AIA Objectives for the Session Develop basic understanding of different formats
More informationLONMARK Functional Profile: Refrigerated Display Case Controller: Defrost Object
Version 1.0 Refrigerated Display Case Controller Defrost Object : 10010 LONMARK Functional Profile: Refrigerated Display Case Controller: Defrost Object 10010-10 1997, LONMARK Interoperability Association
More informationWHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net
WHAT IS THE DIGI-RTU The Digi-RTU is a Heating, Ventilation, and Air Conditioning (HVAC) rooftop unit control kit that is both a demand management and energy usage device. It is designed to improve the
More informationEcotel Free Cool 5-15kW
Precision Air Conditioning Free-cooling Ecotel Free Cool 5-15kW + + Self-contained compact outdoor cabin cooler + + 100% free-cooling + + -48V DC supply option + + Easy serviceability (front component
More informationEnergy Efficient HVAC Systems
Energy Efficient HVAC Systems < NEW YORK, June 10, 2013 /PRNewswire/ -- Reportlinker.com announces that a new market research report is available in its catalogue: Energy Efficient HVAC Systems http://www.reportlinker.com/p0370594/energy-efficient-
More informationGeneral catalogue 2013
IntesisBox your partner for systems integration INTERIOR PORTADA General catalogue 2013 KNX MODBUS BACNET LONWORKS ENOCEAN ASCII OPC SERVER Intesis Software S.L. C/ Milà i Fontanals, 1 bis 1º 08700 Igualada
More informationSignal Doublers. VariTrans A 20300
ProLine Interface Technology Signal Doublers Signal doublers with two switchable calibrated outputs in a 6 mm housing, also for applications with high output loads. The Task Isolation and transmission
More informationST-Box THE PERFECT SPLIT SOLUTION
ST-Box THE PERFECT SPLIT SOLUTION ST-Box 300 ST-Box 200 ST-Box 300 ST 551 Bain-Marie ST-Box 300 ST 521 Operating unit ST-Box 200 ST 960 LED Operating unit ST 58 Satellite display ST 181 Operating unit
More informationAquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.
Aquaflair Uniflair TRAC, TRAF and TRAH Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors 120-350kW Uniflair TRA ranges 115-350kW Air-cooled Chillers Cooling, Free cooling
More informationImproving the climate for data centers
Maximum performance for cool computers Improving the climate for data centers We create a good indoor climate. Supply air Return air Return air Outside air Exhaust air Pressure floor Our ventilation technology
More informationTA Instruments New Features in TAM Air Assistant TM and TAM Assistant TM Software
TA Instruments in TAM Air Assistant TM and TAM Assistant TM Software Notice The material contained in this manual, and in the online help for the software used to support TA Instruments products, is believed
More informationGlobal Optimisation of Chiller Sequencing and Load Balancing Using Shuffled Complex Evolution
Global Optimisation of Chiller Sequencing and Load Balancing Using Shuffled Complex Evolution IAIN STEWART A (MENG) LU AYE A (FAIRAH, FAIE, PHD) TIM PETERSON B (PHD) A Renewable Energy and Energy Efficiency
More informationThe Leviton Load Center THE FUTURE MADE CURRENT
The Leviton Load Center THE FUTURE MADE CURRENT Raising the Bar Again For over 110 years, Leviton has cultivated a rich tradition of safety and innovation, developing electrical products that set the
More informationSwitch to Perfection
Switch to Perfection Traditional Data Centre - Temperatures Ideal Air Temperature: 22 C Chilled Water: 7-9 C Heat Load per Rack: Up to 4,5 Chilling & Pump Set The challenge a thermal image Front View of
More informationtechnical data Systems Individual control systems
technical data Systems Individual control systems Individual control systems 17 1 Possible individual control systems...2 2 BRC2A51 - Simplified remote control Explanation of buttons and functions... 3
More informationFIELD CALIBRATION PROCEDURE FOR ALTEK MODEL 222A
FIELD CALIBRATION PROCEDURE FOR ALTEK MODEL 222A DRAWING NO. 1-827 Date Rev. Revision Record Dr. Review Approve 8FEB94 A Initial Release DJN PBG RPC 25AUG98 B Corrected Specifications DJN AC RPC 26AUG98
More informationPowered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support
A decentralized solution. Many drive applications utilize control panels with complex wiring taking up large amounts of space. These control panels are often mounted away from the application requiring
More informationthat may have a direct effect on your bottom line. The question
VOLUME THREE NUMBER THREE SYNOPSIS A N H V A C N E W S L E T T E R F O R B U I L D I N G O W N E R S A N D M A N A G E R S In this issue... Cost of Owning a Chiller What is your bottom line?....... 1 What
More informationAdvanced Comfort Features For Today s Digital Lifestyle
Advanced Comfort Features For Today s Digital Lifestyle comfort solution overview { A Vantage system gives you unparalleled control of comfort throughout your home. Whether it s an evening cocktail party
More informationPower and Cooling for Ultra-High Density Racks and Blade Servers
Power and Cooling for Ultra-High Density Racks and Blade Servers APC White Paper #46 Richard L. Sawyer Director of Data Center Technology American Power Conversion Company 2005 APC corporation What has
More informationThe most advanced communication gateway solutions for the integration of systems
> Portfolio 2014 The most advanced communication gateway solutions for the integration of systems BACNET ASCII ENOCEAN OPC ME-AC--1-V2 ME-AC--1i ME-AC--15/100 DK-AC--1 DK-AC--1i DK-RC--1 (Domestic line
More informationIntelligent DC UPS Module
Intelligent DC UPS Module 2V/9~36V DC Input, 2V DC Output Uninterruptible Power Supply Module with Diagnostics Features Model Name AUPS-A0 / AUPS-A20 Input Power AUPS-B0 (2V) AUPS-A20 (9~36V) AUPS-B20
More informationPortfolio. The most advanced communication gateway solutions for the integration of systems
> Portfolio The most advanced communication gateway solutions for the integration of systems BACNET ASCII ENOCEAN OPC ME-AC--1-V2 ME-AC--1i ME-AC--15/100 DK-AC--1 DK-AC--1i (Domestic line / Mr.Slim / City
More informationLED Recessed Downlights 12 W LED Round: Fixed or Tilt Downlights 12 W LED Square: Fixed or Tilt Downlights
LUMINAIRE IMAGES ROUND FIXED SQUARE FIXED 367-2614e 1 04.03.2017 ROUND TILT SQUARE TILT Note: Round option shown with black baffle. Square option shown with white baffle. PRINCIPAL LUMINAIRE FEATURES LED
More informationEnergy Management of the Refrigeration Systems at Zurich Airport. Burkhard Bein. Schaffhausen,
Energy Management of the Refrigeration Systems at Zurich Airport Burkhard Bein Schaffhausen, 29.06.18 Overview Content: General Information Refrigeration concept EMS program CS program Three projects for
More informationZTE ZXCR Series DX In-Row Air Conditioning Product Description
ZTE ZXCR Series DX In-Row Air Conditioning Product Description Requirements & Challenges Due to the rapid development of telecommunication technology, the related IT equipment s power consumption is increase
More informationProcon A1M. INSTALLATION MANUAL Version MITSUBISHI ELECTRIC FOR INSTALLERS
Procon A1M FOR INSTALLERS INSTALLATION MANUAL Version 1.1.1 For safe and correct use, please read this installation manual thoroughly before installing the PROCON A1M. MITSUBISHI ELECTRIC Preface Safety
More informationPrecision Cooling. Precision Cooling Advantages
Precision Cooling Today s computing technologies compound conventional cooling problems. Blade servers, communications switches and other electronics are being packed into tighter and tighter spaces. Computing
More informationChiller Replacement and System Strategy. Colin Berry Account Manager
Chiller Replacement and System Strategy Colin Berry Account Manager Current Situation 4 Existing RTAA chillers All units 23 years old Limited service history One unit MUST be replaced immediately One unit
More informationCoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems
CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems Document Revision 0.3 3/23/2015 Attention 1. During the HVAC system automatic operations the CoolMasterNet must be
More informationICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS
ICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS GLOBAL PRESENCE, LOCAL SERVICE WHERE WE MAKE IT WORK WHO WE MAKE IT WORK FOR ACCREDITATIONS i-chiller -10 C to 30 C 1.7 TO 505kW i-chiller COMPACT
More informationNATE Exam Administration Script
NATE Exam Administration Script This script should be completely read for all of NATE s Paper Exams, which includes both NATE and ICE certification exams. Reading this script gives all candidates an equal
More informationHIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.
HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM. SYSTEM LOGICA is the most advanced alternative to the problem of cooling of server rooms MONTAIR is the trademark which represents excellence on the market
More informationCooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.
Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10
More informationIndustry leading low energy evaporative fresh air cooling.
Industry leading low energy evaporative fresh air cooling. Freecool Evaporative Free Air Cooling by Workspace Technology delivers innovative low energy cooling for a range of applications including data
More informationOUR HISTORY OUR MISSION. We believe that good service is based on good communications
OUR HISTORY Established in 2000 MacAir Services is focused on the maintenance and installations of air conditioning systems in commercial office buildings, retail stores, schools, medical centres, gymnasiums,
More informationA Modular Power Conditioning System for Energy Storage
A Modular Power Conditioning System for Energy Storage The right design provides scalability and flexibility Presented at ESA Annual Conference San Jose, CA, July 2011 As power grids across the globe continue
More informationUser's manual. GREE AHU kit. Type: U-Match Version: 1.02
User's manual GREE AHU kit Type: U-Match Version: 1.02 Thank you for choosing AHU com, please read this user's manual carefully before operation and keep it for further reference. If you have lost the
More informationFronius IG Plus. The next generation grid-connected PV inverter.
Fronius IG Plus The next generation grid-connected PV inverter. Maximum earnings. In any weather. The first multi-purpose device. Reliability and maximum earnings security. An outstanding addition to the
More informationECON-ZIP-BASE. ZIP Economizer Base Module
ECON-ZIP-BASE ZIP Economizer Base Module You can mount the ZIP Economizer in any orientation; it is recommended that you mount it in a position that will allow full utilization of the LCD and key pad and
More informationStratadyne Group Inc.
Stratadyne Group Inc. November 22, 2013 Mr. Phil Bowmile, CEO Enerfreeze Canada Inc. 5000 Yonge Street, Suite 1901 Toronto, Ontario M2N 7E9 Sent electronically: phil.bowmile@enerfreeze.ca Re: Chillers
More informationTraining courses 2018
Training courses 2018 The UK s leading specialist air conditioning and refrigeration training provider Get ahead, develop your skills and knowledge Professional training and practical instruction on latest
More informationTHE EUROPEAN REFERENCE
THE EUROPEAN REFERENCE Eurovent Certified Performances certification for IT COOLING UNITS Data Centre World 2019 - London Morgane LAJEUNESSE Project Manager m.lajeunesse@eurovent-certification.com Agenda
More informationCoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems
CoolMasterNet Universal Interface Adapter for HVAC Systems Document Revision 0.6 4/25/20 20 CoolAutomation LTD. Attention 1. During the HVAC system automatic operations the CoolMasterNet must be disconnected
More informationPATENT PENDING RABBIT EARS THERMOELECTRIC GENERATOR
Introduction: The Rabbit Ears CHP (Combined heat & power) is a Thermoelectric wood stove Generator Nominally rated at 100 watts. It has the ability to supply reliable solid-state power. The ONLY moving
More informationREMOTE CONTROL USER MANUAL QUICK CONNECT MINI-SPLIT
COMFORT...BUILT TO LAST QUICK CONNECT MINI-SPLIT REMOTE CONTROL USER MANUAL FOR THE REMOTE CONTROL INCLUDED WITH YOUR PERFECT AIRE MINI-SPLIT AIR CONDITIONER Before using the remote control with your air
More informationEnthusiast System Architecture Certification Feature Requirements
Enthusiast System Architecture Certification Feature Requirements October 2007 DA-03366-001_v02 Enthusiast System Architecture Certification Feature Requirements This document provides PC component vendors
More informationTrane mytest Water-cooled Chiller Performance Validation What you spec is what you get *
Trane mytest Water-cooled Chiller Performance Validation What you spec is what you get * Trane CenTraVac chillers: Designed and built to be the best; tested to prove it Ongoing innovation. Unmatched capabilities.
More informationMicrogeneration Certification Scheme: MCS 005
Microgeneration Certification Scheme: MCS 005 Product Certification Scheme Requirements: Solar Photovoltaic Modules Issue 2.5 This Microgeneration Installation Standard is the property of Department of
More informationBulletin Installation of Solar Photovoltaic Systems Section 50; Rules: , , ; Tables 11 and 19 Issued July 2010
Ontario Electrical Safety Code - Bulletins 50-1-0 Bulletin 50-1-0 Installation of Solar Photovoltaic Systems Section 50; Rules: 84-020, 84-024, 84-030; Tables 11 and 19 Issued July 2010 Scope (1) Introduction
More informationSurge Protection for Industry
Surge Protection for Industry It s our business to help yours thrive. Rayvoss is Designed to Protect any Industrial Application Industrial Grade Protection The Rayvoss family of products is configurable
More informationVR 80 Remote Control Device
For the owner and heating engineer Operating and installation manual VR 80 Remote Control Device Bus modular control system VR 80 GB Contents Contents Notes on the documentation...... 4 Other valid documents...
More informationECL Comfort V a.c. and 24 V a.c.
Data sheet ECL Comfort 200 230 V a.c. and 24 V a.c. Application The ECL Comfort 200 electronic controller is pre-programmed for a variety of different applications. Each application has its own card describing
More informationDK-AC-KNX-1. Specifications. Main features. Info
IntesisBox 2015 DK-AC-KNX-1 IntesisBox DK-AC-KNX-1 allows monitoring and control, fully bi-directionally, all the operational parameters of DAIKIN air conditioners from KNX installations. Compatible with
More informationA) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.
DATA CENTRE COOLING SYSTEM A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems. 1. Cooling Optimized to Electronic
More informationBENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS
BENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS Asetek has leveraged its expertise as the world-leading provider of efficient liquid cooling systems to create its RackCDU and ISAC direct-to-chip liquid
More informationDamp Heat Test Report
Damp Heat Test Report Issue by Product Model Product Description Engineering Department Report No:0809DT0376 Rugged BOX PC : I530EAC-201 I530EAC-201 Embedded Industrial Automation Controller New product
More informationAVANTAGE DATA CENTER. The only ecological «green» data center in Russia with application of the best innovative technologies
AVANTAGE DATA CENTER The only ecological «green» data center in Russia with application of the best innovative technologies AVANTAGE 3 700 m 2 Administrative building 14 diesel-rotor uninterrupted power
More informationDrives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)
Drives and motors A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC) The power behind the data Private and public businesses, from banks to
More informationSTUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK
STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK The Studio 1800 is a combined Programmer and Temperature Controller which has been specifically designed for use with pottery kilns. Control of
More informationMonitoring various parameters with one power meter!
Eco-POWER METER KW2M SERIES Conforming to EMC Directive Monitoring various parameters with one power meter! Equipped with multi functionalities and two ports * *UL61010-1:2012 CAN/CSA-C22.2 No.61010-1-12
More information1/7. Field settings table [6.8.2] =... ID66F2 / ID66F3. Applicable indoor units. *GSQH10S18AA9W ThermaliaC12* Notes 4P E
/7 [6.8.] =... ID66F / ID66F3 Applicable indoor units *GSQHS8AA9W ThermaliaC* Notes /7 User settings Preset values Room temperature 7.4.. Comfort (heating) R/W [3-7]~[3-6], step: A.3..4 C 7.4.. Eco (heating)
More informationNetworks as the enabler of the new energy world
Networks as the enabler of the new energy world Anders Olsson, Vice - CEO E.ON Nordic IEEE Innovative Smart Grid Technologies Conference, Gothenburg, 11th October 2010 Content Global trends EU Climate
More informationBLUE 3 INSTALLATION GUIDE
BLUE 3 INSTALLATION GUIDE CATCH Power BLUE 3 Installation manual - Page 1 IMPORTANT This product must be installed by a licensed electrician. This product must be installed according to the AS3000 Australian
More information3-Axis Stepper Drive Datasheet MX3660
3-Axis Stepper Drive Datasheet MX3660 3-Axis Stepper Drive + Breakout Board, 20-60VDC, 6A Peak Version 0.0.2 http://www.leadshine.com Features Three individual stepper drive boards Suitable for NEMA17
More informationSetting Your Business Apart Through Industry Certification
Setting Your Business Apart Through Industry Certification Newark, N.J., August 24, 2016 Valerie Briggs Director, Marketing and Business Development North American Technician Excellence (NATE) North American
More informationAlcatel - Lucent 8115 Audioffice
Alcatel - Lucent 115 Audioffice User guide R100 AL90050USAAed01 2 Table of contents Important information 3 Safety guidelines 3 1 Discover your Alcatel-Lucent 115 Audioffice dock Box content Your Alcatel-Lucent
More informationChilled Water REMOTE CONTROLLER OPERATION MANUAL MAN-O-CRC4AH intensity.mx
Chilled Water REMOTE CONTROLLER OPERATION MANUAL intensity.mx MAN-O-CRC4AH-061 CONTENTS Remote Controller Specifications---------------------------------------1 Performance Features-----------------------------------------------------1
More information