1 Energy Study Programs December
2 Agenda Energy Study Programs Overview Recommissioning Engineering Studies Data Center Studies Custom Rebates What makes a good energy study? 2
3 Energy Study Program Overview 3
4 Funding Study Funding Funded at up to 75% of study cost, to a maximum from Xcel Energy of $25K Funding for all studies tied to energy savings potential Proprietary Funding Calculations don t promise any funding amount until preapproval 4
5 Funding continued Implementation Up to $400/kW saved for peak kw saving measures kwh reduction rebates $400 per implied kw (approx. $0.0457/kWh) implied kw = kwh/8760 Customer will earn the higher of the two Natural gas implementation rebates for our gas customers $5.00/Dth 5
6 General Guidelines Preapproval required We can pay for implementation with and without a study "Fast Track" option Prefer unlocked Excel worksheet or hand calculations 6
7 Preapproval Customer submits study preapproval application, and a proposal Preapproval application should include: Customer, vendor and account manager signatures Study cost Proposal Customer should not start study until application is preapproved 7
8 Preapproval continued Proposal should contain Building description Equipment description What you will analyze Preliminary observations for opportunities Identify what you already know is wrong with the building Customer concerns Identify if they are a District Energy customer If approved, we ll the customer We ll copy you and the account manager 8
9 Benefits Studies identify savings Identifies energy savings and rebates Builds business case for project approval Details how to run at peak efficiency Implementation realizes savings Improves ROI for equipment and system improvements Helps manage energy costs Can improve reliability 9
10 Recommissioning 10
11 Xcel Energy s Definition of Recommissioning (RCx)? Recommissioning is the process of returning a building s mechanical and lighting systems, along with the building controls, to their peak performance. This is done through the investigation of the existing system performance, the adjustment of the operating parameters and the repair of faulty equipment. Recommissioning is intended to optimize the existing systems without having to add new components, which typically exposes low cost measures with attractive paybacks. 11
12 Slide 11 XPR114 Text overlaps header design; bullet should align with left margin, similar to other slides XP Production Release 1.0, 12/16/2011
13 Recommissioning Reviews Existing systems Central heating/cooling Air handling units Heat pumps/rooftop units Exhaust systems Pumping Outside air Central chilled water loop Economizers Existing controls Sequence of operations Resets Start/stop times Building pressurization 12
14 Nationwide Study on Recommissioning Measures 122 projects; 950 measures Categorized into 44 measure types Simple Payback <2 years: 91% Median Simple Payback: 8 months Controls measures were top savings measures A Study on Energy Savings and Measure Cost Effectiveness of Existing Building Commissioning, December 15 th, 2009, Portland Energy Conservation, Inc. 13
15 Nationwide Study on Recommissioning Measures Key Measure Mix : 7 measures that contribute 65% of total cumulative savings Top Cumulative Saving Measures and % of Savings Key Measure Mix % of Total Savings Revise control sequence 21% Reduce equipment runtime 15% Optimize airside economizer 12% Add / optimize SAT reset 8% Reduce coil leakage 4% Reduce / reset DSP setpoint 4% Add / optimize optimum start/stop 3% Add / optimize CWST reset 2% A Study on Energy Savings and Measure Cost Effectiveness of Existing Building Commissioning, December 15 th, 2009, Portland Energy Conservation, Inc. 14
16 Why Customers Participate* It provides concrete numbers for financial analysis Provides a roadmap for improvement, helps prioritize projects Xcel Energy is viewed as a neutral endorser of energy savings options Studies are tangible evidence of their desire to go green *Based on market research completed by Xcel Energy Summer
17 Recommissioning Energy Savings Calculation Tool 16
18 What is the tool? Xcel Energy has developed an energy savings calculation template for use by study providers We developed this to both standardize and simplify the study preparation and review process Excel worksheet based Addresses 19 typical ECOs Calculates energy and cost savings for inclusion into the final report 17
19 How was it developed? Tool was developed in partnership with a third-party engineering firm and Xcel Energy Released in December of 2009 Tested by third-party study providers and internal stakeholders ECOs will be added in the future Tool will evolve Most common ECOs will be added Want feedback 18
20 Energy Conservation Opportunities AHU Air Leak Reduction AHU Coil Cleaning (maintenance savings only) AHU Optimize Economizer AHU Outside Air Reduction (including DCV CO2 control) AHU Run Time Reduction (including Optimum start/stop) AHU Supply Air Static Pressure Adjustment/Reset AHU Supply Air Temperature Reset AHU VAV Minimum Flow Reduction Chilled Water Supply Temperature Set Point Adjustment Condenser Water Supply Temperature Set Point Adjustment 19
21 Energy Conservation Opportunities Eliminate Simultaneous Heating and Cooling Heating Water Supply Temperature Set Point Adjustment Lighting & Equipment Run Time Reduction Unoccupied Setback Pump Total Dynamic Head Pressure Reduction Pump Differential Pressure Set Point Adjustment/Reset Pump Minimum Flow Reduction Waterside Economizer and Cooling Plant Enable Heating Plant Enable 20
22 Engineering Studies 21
23 Engineering Assistance Studies Analyze a major process or system to help decision-making on new installations and energy efficiency improvements Xcel Energy will pay up to 75% of the study cost, not to exceed $25,000 Compare at least 2 different options and provide energy-savings calculations Preapproval is required for studies Common types of studies: Cooling system replacement Custom Efficiency Refrigeration Space/process heating 22
24 Data Center Efficiency 23
25 Efficiency Opportunities IT/inside the cabinets/racks: Virtualization/Consolidation of the servers High efficiency servers and power supplies Blade servers Management software Storage consolidation and optimization Network consolidation 24
26 Efficiency Opportunities Facility: Mechanical Air management Louvered floor tile systems Raised floor, ceiling configuration Hot/cold aisle configuration/separation In-rack cooling Economizer (air or water side) Hot spot elimination Raise supply air temperature VAV drives on fans Raise chilled water temperature Efficient chillers or DX units Ultrasonic or evaporative humidification 25
27 Efficiency Opportunities Facility: Electrical High efficiency transformers Lighting Battery storage systems High efficiency UPS systems Efficient power distribution 26
28 Bundled Rebates Leverage the cascade effect: Server/IT savings yield reduced cooling and electrical needs Allows for a single rebate payback calculation Paybacks between: 9 months (MN); 1 yr (CO) and 15 years, or the project life 27
29 Data Center Study Options Better fits customer need Study funding IT, facility or holistic Project rebates Identified in a study (bundle) Individual projects (no study) 28
30 How to participate All Study Programs 29
31 Qualification review Recommissioning and Data Center Efficiency We qualify individuals, not companies Steps: Submit Study Provider Application To Jeff Jackson in MN To Derek Shockley in CO Include work history and experience Include energy savings calculations 30
32 How to Participate - Projects Projects without study Submit Custom or Project Preapproval application Detail project, option A vs. option B Must be preapproved prior to purchase Notification Letter Monitoring Agreement if applicable 31
33 How to Participate - Studies Study path 1. Study preapproval Funding available: up to 75%; up to $25, Study Review, Approval, Monitoring Agreement 3. Study Rebate 4. Project Implementation 5. Rebate 32
34 Data Center Case Study 33
35 Retailer Measures identified for this project: Server virtualization & consolidation Centralized ultrasonic humidification 34
36 Retailer 2,021,220 kwh savings kw estimated maximum demand savings $141,124 estimated annual electric cost savings $132,597 estimated project cost 0.75 years estimated simple payback $26,754 estimated Xcel Energy rebate $22, estimated rebate available if projects competed individually without data center study 35
37 What makes a good energy study? Xcel Energy s Energy Efficiency Engineers 36
38 Energy Studies Write a clear proposal with clearly defined objectives The report needs to be easy to read with clear findings Calculations to prove the results of the study Avoid Our past project saved 15% so Include technical data sheets when appropriate Include single diagrams when appropriate Work towards solid numbers for cost estimates Don t recommend another study 37
39 Energy Studies Xcel Energy specific Have all the numbers match between the ECO form, narratives, and ECO descriptions Use correct average costs for electricity and gas Don t submit work already paid for by customer Don t deliver report before we approve it Understand all our prescriptive and Custom programs Know the difference between kw reducing ECO s and non-peak savings 38
40 More information Xcelenergy.com/rebates Xcelenergy.com/tradepartners Feature sheet Study preapproval application Study rebate application Fast track application New collateral Contact: Trade Relations Manager Jeff Jackson 39
41 Questions? Thank you for attending! 40
42
Retro-Commissioning Report
10 Retro-Commissioning Report Retro-Commissioning Retro-Commissioning is the process for identifying intrinsic operational and energy related issues in the facilities DDC system and providing a mechanism
More informationSilicon Valley Power Data Center Program Rebate Application
Contact Information Tax Status (check one) Sole Proprietor Contact Name Phone Corporation Partnership Company Email address Government Not-For-Profit Customer/Facility Information Company Name SVP Account
More informationCenterPoint Energy Retro-Commissioning Program Application
CenterPoint Energy Retro-Commissioning Program Application CenterPoint Energy Retro-Commissioning Program is offered to Commercial and Industrial customers in our service territory to enhance their facility
More informationEnergy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director
Energy Logic: A Roadmap for Reducing Energy Consumption in the Data Center Emerson Network Power Ross Hammond Managing Director Agenda Energy efficiency Where We Are Today What Data Center Managers Are
More informationBuilding Tune-Up Program Application
Thank you for applying for Vectren s Building Tune-Up Program ( Program )! The Program provides a study focused on optimizing the energy performance of a facility by identifying no-and low-cost energy-saving
More informationXcel Energy s Small Building Tune-Up. Michelle Beaudoin, Product Manager
Xcel Energy s Small Building Tune-Up Michelle Beaudoin, Product Manager Product Background Result of 2012 New Mexico Settlement Regulatory Approval CO May 2014 NM August 2014 Third Party Implemented 2
More informationCommercial Retro-Commissioning Program Manual for 2016 SECTION 1
Commercial Retro-Commissioning Program Manual for 2016 SECTION 1 Introduction The Commercial Retro-Commissioning Program (RCx) is designed to achieve demand and energy savings in commercial facilities.
More informationPrescriptive Program Rebate Application
Prescriptive Program Internal use only Xcel Energy OID Check the appropriate program box for your rebate. Cooling Data center efficiency FSO (Fluid System Optimization) Foodservice equipment Heating Lighting
More informationComEd Retro-Commissioning and Monitoring-Based Commissioning
ComEd Retro-Commissioning and Monitoring-Based Commissioning Rick Tonielli Sr. Program Manager C O N F I D E N T I A L Territory profile ComEd is an electric delivery company providing service to 3.8 million
More informationMEASURE MONITOR UNDERSTAND
MEASURE MONITOR UNDERSTAND Presented by Alistair Hunt Energy Monitoring, Measurement metrics Where and What 1 History & Background Company Timeline 18 Years Comrac & Sinetica founded 15 Years Raritan Integration
More informationFuture of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power
Future of Cooling High Density Equipment Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Agenda Issues facing the Data Center Managing the explosive
More informationA New Paradigm for Retrocommissioning: Moving Building Science to Green Collar Trades
A New Paradigm for Retrocommissioning: Moving Building Science to Green Collar Trades Presented by: Keith Forsman,PE Pacific Gas & Electric Company August 17, 2010 .From Building Science to Green Collar
More informationEngineered Energy Solutions An Overview. Controls, Automation and Energy Conservation
Engineered Energy Solutions An Overview Controls, Automation and Energy Conservation Engineered Energy Solutions Independent Control System Integration and Engineering Firm specializing in the energy efficient
More informationIntroducing the Heat Wheel to the Data Center
Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure Specialist KyotoCooling International Critical Facilities Round Table 1 A New Free Cooling Technique
More informationThe challenge is that BAS are often very complex with 1000s of data points to review. EMS Optimization Software
EMS Optimization Software Often immediate energy savings can be achieved with proper set points, sequencing, scheduling and fault detection of the Building Automation System (BAS). The challenge is that
More informationData Center Energy Savings By the numbers
Data Center Energy Savings By the numbers Chris Kurkjian, PE HP Critical Facility Services provided by EYP Mission Critical Facilities 2008 Hewlett-Packard Development Company, L.P. The information contained
More informationAchieving Operational Excellence
Achieving Operational Excellence Energy Efficient Operations in a Shrinking Budget Environment 2010 Energy/Facilities Connections Conference Innovative Approaches for a New Decade DID YOU KNOW? Nine out
More informationData Centers. Powerful Solutions That Put You in Control. Energy Management Solutions. Where your energy dollars are used. 1
Energy for What s Ahead SM Energy Management Solutions Data Centers Powerful Solutions That Put You in Control Ready to take a byte out of your data center energy use and become more cost-effcient? Data
More informationDEDICATED HEAT RECOVERY UNIT (DHRC)
DEDICATED HEAT RECOVERY UNIT (DHRC) AHRI CERTIFICATION Air-Conditioning, Heating, and Refrigeration Institute Multistack is AHRI Certified and continues to certify products as they are developed AHRI Certification
More information18 th National Award for Excellence in Energy Management. July 27, 2017
18 th National Award for Excellence in Energy Management July 27, 2017 ICICI Bank, Data Centre, August Hyderabad 30 & 31, 2017 ICICI Bank - Revolution in Digital Banking Over 100,000 Digital POS in 4 months
More informationTen Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42
Ten Cooling Solutions to Support High-density Server Deployment Schneider Electric Data Center Science Center White Paper #42 1 Introduction 2 Introduction This paper provides 10 approaches for increasing
More informationEnergy Action Plan 2015
Energy Action Plan 2015 Purpose: In support of the Texas A&M University Vision 2020: Creating a Culture of Excellence and Action 2015: Education First Strategic Plan, the Energy Action Plan (EAP) 2015
More informationDriving Proactive Facility Operations with Automated HVAC Diagnostics
Driving Proactive Facility Operations with Automated HVAC Diagnostics Turn HVAC Data into Actionable Information AKA Monitoring Based Commissioning Ongoing Commissioning Automated Fault Detection & Diagnostics
More informationDATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency
DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency September 27 th, 2013 Tejas Desai, PE CEM CEA LEED AP Sameer Behere, PE CEM LEED AP Agenda Problem: Quick fixes can
More informationwhere we are, where we could be, how we can get there. 12/14/2011
Central Plant Optimization ASHRAE National Capitol Chapter - PES Wednesday, Nov 7, 2011 Dave Klee, LEED AP Director, Optimized Building Solutions Johnson Controls, Inc. 1 1 J o http://www.johnsoncontrols.com/cpo
More informationHow Big Data Analytics Helps Hotels Improve Maintenance and Comfort, and Save Energy
How Big Data Analytics Helps Hotels Improve Maintenance and Comfort, and Save Energy Critical facility management drivers are impacting all industries Sustainability Big Data/Cloud Open Building Systems
More informationPresentation. Guaranteed Energy Savings Performance Project
Presentation Guaranteed Energy Savings Performance Project Greg Spiro, PE, CEM, LEED-AP Georgia Institute of Technology Senior Mechanical Engineer Facilities Design & Construction 470-351-9867151 6th Street
More informationGreen IT Project: The Business Case
Green IT Project: The Business Case Indumathi Lnu University at Albany DATE We will discuss Identifying green IT projects Funding green IT projects Building the business case Case study: University at
More informationJames Donahue Control Consultants, Inc.
James Donahue Control Consultants, Inc. Founded 1989 NE s premier distributor of Building Automation products Customer Base: Controls Contractors and Systems Integrators In-House Engineering Department
More informationIBM - Energy Efficiency Recommissioning: Improving Buildings Systems Efficiency Jean-Pierre Boulianne, Pierre Lefèbvre, Yves Veilleux ICEBO 2013
IBM - Energy Efficiency Recommissioning: Improving Buildings Systems Efficiency Jean-Pierre Boulianne, Pierre Lefèbvre, Yves Veilleux ICEBO 2013 IBM Bromont - Recommissioning IBM Manufacturing Plant Bromont,
More informationPROCESS COOLING STUDY WORKSHEET
PROCESS COOLING STUDY WORKSHEET January, 0 December, 0 DIRECTIONS: Please save a copy of this form to your computer by selecting FILE/SAVE AS before entering text and numbers. Then fll in your information
More informationInside the Data Center: Opportunities for Energy Efficiency
Pacific Gas and Electric Company Presented to Technologies and Practices for Efficient & Reliable Data Centers Inside the Data Center: Opportunities for Energy Efficiency Mark Bramfitt Sunnyvale, California
More informationTWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months
TWO FINANCIAL IMPACT STUDIES Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months TWO FINANCIAL IMPACT STUDIES Seal IT Equipment Cabinets for Significant
More informationHow Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October
How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals Michael Gagnon Coolcentric October 13 2011 Data Center Trends Energy consumption in the Data Center (DC) 2006-61 billion
More informationWhat s New for Data Centers in Title Jeff Stein, PE Taylor Engineering
What s New for Data Centers in Title 24-2013 Jeff Stein, PE Taylor Engineering SVLG Workshop November 14, 2013 About Jeff Stein Principal, Taylor Engineering 2000 - now Professional Experience Eley Associates,
More informationEfficiency Works Business: 2017 Rebates & Goals. January 17, 2017
Efficiency Works Business: 2017 Rebates & Goals January 17, 2017 Platte River Power Authority provides electricity to Estes Park, Fort Collins, Longmont, and Loveland Substation Generation Coal / Natural
More informationMission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire
Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices
More informationHIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.
HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM. SYSTEM LOGICA is the most advanced alternative to the problem of cooling of server rooms MONTAIR is the trademark which represents excellence on the market
More informationEfficiency of Data Center cooling
Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and
More informationSaving Energy with Free Cooling and How Well It Works
Saving Energy with Free Cooling and How Well It Works Brent Draney HPC Facility Integration Lead Data Center Efficiency Summit 2014-1 - NERSC is the primary computing facility for DOE Office of Science
More informationDUKE UNIVERSITY DESIGN & CONSTRUCTION STANDARDS
1 25 95 00 Integrated Automation Control Sequences for HVAC GENERAL The HVAC operational sequences in this guideline are commonly used by Duke University. They are being provided as a preferred design
More informationSaving Energy and Reducing Costs Through Better Use of Building Automation Systems
Session: Low/No Cost Solutions Through BAS Saving Energy and Reducing Costs Through Better Use of Building Automation Systems Mark M. Duszynski Johnson Controls Federal Systems August 9, 2016 Rhode Island
More informationDatacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary
Datacenter Efficiency Trends Cary Roberts Tellme, a Microsoft Subsidiary Power Slashing Tools P3 Kill-A-WATT Measures min, max, and instantaneous voltage and current draw Calculates power (watts), kilowatt
More informationBuilding Re-Tuning (BRT) Lesson 4: SOI Air-Handling Unit Part II
Building Re-Tuning (BRT) Lesson 4: SOI Air-Handling Unit Part II Lesson 4: Sections Review of last class (0:20) Section 1: AHU: Discharge air temperature control (0:45) Break (0:10) Section 2: AHU: Heating
More informationBAS Chillers 8/15/2016. Achieving Energy Savings with BAS and Data Analytics Guanjing Lin Lawrence Berkeley National Laboratory August 10, 2016
Session 7: Building Automation and Operation Tools Outline Analytics Tools to Supplement BAS Achieving Energy Savings with BAS and Data Analytics Guanjing Lin Lawrence Berkeley National Laboratory August
More informationCommitted to Energy Efficiency
RESOLUTE Resolute Helps PNC Arena Reduce Energy Consumption and Costs While Improving Fan Comfort Lacking the visibility, real-time data and analytics needed to optimize facility performance and reduce
More informationGreen IT and Green DC
Green IT and Green DC Alex SL Tay Regional Service Product Line Manager Site & Facilities Services, IBM ASEAN 1 What our clients are telling us We are running out of space in our data center We have environmental
More information2018 Business Cooling Equipment Rebate Application
2018 Business Cooling Equipment Rebate Application LIMITED FUNDING: Contact your local Utility to confirm rebate availability. CUSTOMER INFORMATION Check here if you are applying for multiple Business
More informationMetering and Energy Retrofits for the GSA
Metering and Energy Retrofits for the GSA 2012 Rocky Mountain Chapter ASHRAE Technical Conference Leadership in HVAC&R April 20 th, 2012 Juan Moreno and Christian Marsh-Frydenlund 1 1 Agenda Project Overview
More informationThe Energy. David L. Moss Dell Data Center Infrastructure
The Energy Advantages of Containment Systems David L. Moss Dell Data Center Infrastructure www.dell.com/hiddendatacenter Summary The Uptime Institute estimates that the cost to build a new 20,000 square
More informationCommercial HVAC and Other Measures for 7P. Outline
Commercial HVAC and Other Measures for 7P Conservation Resource Advisory Committee January 28, 2014 Outline Commercial HVAC data from CBSA Overview of Commercial HVAC Measures A few other Commercial Measures
More informationOptimizing Cooling Performance Of a Data Center
ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal. This article may not be copied nor distributed in either paper or digital form without ASHRAE s permission. For more information about ASHRAE,
More informationClose Coupled Cooling for Datacentres
Close Coupled Cooling for Datacentres Dr Fathi Tarada Mosen Ltd fathi.tarada@mosenltd.com www.mosenltd.com Agenda Increasing Power Densities Raised Floor Limitations Hot and Cold Aisle Enclosures Close
More informationAisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings
WHITE PAPER AisleLok Modular Containment vs. : A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings By Bruce Long, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies, Inc.
More informationComprehensive Energy Management & Utility Master Plan
Comprehensive Energy Management & Utility Master Plan OVERVIEW University of Utah & Health Science Campus Overview Campus Transformation Value Drivers and Challenges Integrated Energy Planning Approach
More informationMSYS 4480 AC Systems Winter 2015
MSYS 4480 AC Systems Winter 2015 Module 12: DATA CENTERS By Satwinder Singh 14/05/2015 1 Data Centers Data Centers are specialized environments that safeguard your company's most valuable equipment and
More informationCHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM
CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM 1. Category (Check one and indicate New or Existing, if applicable) Commercial Buildings New or Existing Institutional Buildings: Educational Facilities New
More informationDigital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect
Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect of Record: SPARCH Project Overview The project is located
More informationPassive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer
Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling While CRAH cooling has been
More informationLIFE CYCLE COST ANALYSIS, CRITERIA AND DATA SHEETS DOCUMENT NUMBER: APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL
LIFE CYCLE COST ANALYSIS, CRITERIA AND DATA SHEETS DOCUMENT NUMBER: 15000 APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL DATE OF ISSUE: 10-26-11 - Minor revisions to Data Sheets 04-08-10 - Allowed use
More informationDesigning Ultra-Efficient Building Cooling Systems
Designing Ultra-Efficient Building Cooling Systems Design to Apply Effective Optimization Technologies To Chiller Plants and Air Systems ASHRAE Triangle Chapter Raleigh, NC November 16, 2016 Tom Hartman,
More informationReducing Data Center Cooling Costs through Airflow Containment
FEATURE Reducing Data Center Cooling Costs through Airflow Containment Implementing a containment solution in the data center costs much less than the alternatives of adding air handlers or other supplemental
More informationThe Basics of HVAC Operation and the Role of Automation. Mr. Jay Zaino GxP Automation, LLC
Welcome The Basics of HVAC Operation and the Role of Automation Mr. Jay Zaino GxP Automation, LLC Agenda Introduction / Overview HVAC Basics HVAC in Life Science Market Automation s role in it all 1 Introduction
More informationMoving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet
Moving Containment Inside the Enclosure Presented by Jeff Markle Great Lakes Case & Cabinet Containment Containment : To put constraint upon; to restrain; to confine; to keep within bounds Containment
More informationSecond Stakeholder Meeting for Nonresidential HVAC Proposals Based on ASHRAE Revisions to Waterside Economizer
Second Stakeholder Meeting for Nonresidential HVAC Proposals Based on ASHRAE 90.1-2016 Revisions to Waterside Economizer March 15, 2017 Stefan Gracik 510-663-2070 sgracik@integralgroup.com Agenda 1. Background
More informationMay Hands-on Guidance. Measurable Results. SUPPLIER EFFICIENCY PROGRAM
May 2015 Hands-on Guidance. Measurable Results. SUPPLIER EFFICIENCY PROGRAM REACHING OUTSIDE OUR WALLS WHAT A scalable education and training platform that helps suppliers reduce their energy use and costs
More informationRecapture Capacity for Existing. and Airflow Optimization
Recapture Capacity for Existing Data Centers Through Cooling and Airflow Optimization Introduction Challenges and Trends Agenda Cooling & Airflow Optimization Takeaways Learning Objectives Recognize opportunities
More information7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
More informationGoogle s Green Data Centers: Network POP Case Study
Google s Green Data Centers: Network POP Case Study Table of Contents Introduction... 2 Best practices: Measuring. performance, optimizing air flow,. and turning up the thermostat... 2...Best Practice
More informationREPORT. Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD. Prepared for:
REPORT Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD Prepared for: San Diego Supercomputer Center 10100 John J Hopkins Drive San Diego, CA 92037 May 11, 2009
More informationNext Generation Cooling
Next Generation Cooling Server Manufacturer Perspective Practical and Cost Effective David Moss Data Center Strategist Dell 1 Why Chip, Row, or Rack? Density? Energy Don t be scared; I don t see 50kW/rack
More informationData Center Design: Power, Cooling & Management
Presents Data Center Design: Power, Cooling & Management The Legacy Data Center Large (oversized) UPS Systems Large Power Distribution Systems N, N+1, 2N, 2(N+1) UPS topologies Large Free standing
More informationWaterside Economizing in Data Centers: Design and Control Considerations
2009, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Published in ASHRAE Transactions 2009, vol. 115, part 2. For personal use only. Additional reproduction,
More informationEnergy Efficiency Solutions for Your Data Center
Energy Efficiency Solutions for Your Data Center Chapter One: Cooling Assessments Click a section below You Know You Need a Cooling Assessment When Cooling Assessments Yield Benefits Now and in the Future
More informationInternational 6SigmaDC User Conference CFD Modeling for Lab Energy Savings DCSTG Lab Temperature Setpoint Increase
International 6SigmaDC User Conference CFD Modeling for Lab Energy Savings DCSTG Lab Temperature Setpoint Increase Chris Noland cnoland@cisco.com Vipha Kanakakorn vkanakak@cisco.com 3/4/2010 Goal & Limitations
More informationT66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management
T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management Name Doug Demian Title Application Engineer Date November 7 & 8, 2012 Rev 5058-CO900C Copyright 2012 Rockwell
More informationData Center Design: Power, Cooling & Management
Presents Data Center Design: Power, Cooling & Management The Legacy Data Center Large (oversized) UPS Systems Large Power Distribution Systems N, N+1 UPS topologies Large Free standing Static Switches
More informationDrives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)
Drives and motors A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC) The power behind the data Private and public businesses, from banks to
More informationPower & Cooling Considerations for Virtualized Environments
Power & Cooling Considerations for Virtualized Environments Cisco Data Center Day 2008 31-01-2008 APC-MGE Vision & Mission OUR VISION APC-MGE products ensure availability wherever data is created, transmitted
More informationCRITICAL FACILITIES ROUNDTABLE HEAT REMOVAL IN DATA CENTERS ENGINEERED SOLUTIONS
CRITICAL FACILITIES ROUNDTABLE HEAT REMOVAL IN DATA CENTERS ENGINEERED SOLUTIONS Peter Klock, P.E., President ESC Engineering Services Company peter@escengineering.com Bill Henry, P.E., Consulting Mechanical
More informationImpact of Air Containment Systems
White Paper June 2012 WP-20 Impact of Air Containment Systems Reducing Energy Consumption Introduction: The Importance of Maintaining Data Center Cooling Energy Efficiency Data centers are mission-critical
More informationOptimizing the Existing Building Cx Process:
Optimizing the Existing Building Cx Process: Integrating EBCx into ESPCs Lia Webster, P.E. Senior Engineer Portland Energy Conservation, Inc. AIA Quality Assurance Learning Objectives 1. Identify ways
More informationPay for Performance. Emerging Technologies. ET Emerging Technologies Showcase. Emily Levin Vermont Energy Investment Corporation
Emerging Technologies Pay for Performance ET Emerging Technologies Showcase Emily Levin Vermont Energy Investment Corporation Kathleen Belkayat Energy Trust of Oregon March 28, 2017 Sponsored by BPA s
More informationPROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES
PROCESS & DATA CENTER COOLING How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES CONGRATULATIONS 2 BOLD PREDICTION 3 Where We Are TODAY Computer Technology NOW advances more
More informationVirtualization and consolidation
Virtualization and consolidation Choosing a density strategy Implementing a high-density environment Maximizing the efficiency benefit Anticipating the dynamic data center Schneider Electric 1 Topical
More informationAdvanced Rooftop Controller
Advanced Rooftop Controller Preliminary Seventh Power Plan Energy Efficiency Estimates Conservation Resources Advisory Committee Meeting December 17, 2014 Presentation Outline Advanced Rooftop Controller
More informationTrane Engineering News Chiller Plant Case Study: Variable-Primary Flow Series Chillers with Free Cooling
Trane Engineering News Chiller Plant Case Study: Variable-Primary Flow Series Chillers with Free Cooling CHILLER PLANT CONTROLS The challenges of producing chilled water are not the same as those a decade
More informationClose-coupled cooling
Close-coupled cooling Intelligently controlled high-performance InRow cooling for the IT environment APC TM by Schneider Electric close-coupled cooling products provide a modular, scalable, and predictable
More informationData Center Optimized Controls
Data Center Optimized Controls Controls Agenda 30 min. Emerson Control Products icom (Dynamic Thermal Optimization) 20 min. Station Rotation Station 1: Controller Challenge Station 2: Wireless Demo 5 min.
More informationEvaluation and Modeling of Data Center Energy Efficiency Measures for an Existing Office Building
Evaluation and Modeling of Data Center Energy Efficiency Measures for an Existing Office Building Dhayanandh Murugan 1, Gabrielle Viola McMorrow 1, Dr.Liping Wang 1, Greenberg Steve 2 1 University of Wyoming,
More informationA separate CRAC Unit plant zone was created between the external façade and the technical space.
Nominee: FES Co Ltd Nomination title: HP Cold Cube The Doxford Facility is a highly secure Data Centre. The challenge was to take advantage of the previous investment in highly resilient infrastructure
More informationAgenda Date: 8/23/17 Agenda Item: SB CLEAN ENERGY
Agenda Date: 8/23/17 Agenda Item: SB STATE OF NEW JERSEY Trenton, New Jersey 08625-0350 www.nj.gov/bpu/ CLEAN ENERGY IN THE MATTER OF THE CLEAN ENERGY PROGRAM AUTHORIZATION OF COMMERCIAL AND INDUSTRIAL
More information2013 Building Energy Efficiency Standards Non-Residential HVAC Alterations
B 2013 Building Energy Efficiency Standards Non-Residential HVAC Alterations BUSINESS AND PROFESSIONS CODE, SECTION 7110 Willful or deliberate disregard and violation of the building laws, including the
More informationApplication of TileFlow to Improve Cooling in a Data Center
Case Study Application of TileFlow to Improve Cooling in a Data Center 3025 Harbor Lane North, Suite 300 Plymouth, MN 55447 USA Copyright 2004 Innovative Research, Inc. 2 Introduction A large insurance
More informationIT Air Conditioning Units
IT Air Conditioning Units Modern Flexible Effective Energy Saving CoolTeg Plus and CoolTop overview CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC CoolTop Installation Between IT racks On top of IT rack
More informationEvaporative free air cooling technology Providing evaporative free air cooling solutions.
Evaporative free air cooling technology Providing evaporative free air cooling solutions. Creating an effective workspace environment data centre free air cooling technology FreeCool - Evaporative Free
More informationWelcome Association of Energy Engineers to the Microsoft Technology Center
Welcome Association of Energy Engineers to the Microsoft Technology Center Today s Agenda 10:00 10:30 What s new in data center energy efficiency planning and implementation? 10:30 11:00 ASHRAE data center
More informationCisco Lab Setpoint Increase. Energy Efficient Data Center Demonstration Project
Cisco Lab Setpoint Increase Energy Efficient Data Center Demonstration Project About the Energy Efficient Data Center Demonstration Project The project s goal is to identify key technology, policy and
More informationDoing More with Less: Maintaining, Operating, and Improving your BMS. Bernard Keister, V PE Senior Engineer Guttmann & Blaevoet Consulting Engineers
Doing More with Less: Maintaining, Operating, and Improving your BMS Bernard Keister, V PE Senior Engineer Guttmann & Blaevoet Consulting Engineers AIA Quality Assurance Learning Objectives 1. Develop
More informationCooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.
Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10
More information