1 Pipeline Condition Report 2 nd Quarter 2011 POMA Operation and Maintenance Subcommittee Meeting
2 Outline HSE Performance Overall Pipeline Condition Routine Works External & Security Issues Major Projects Status Road and ROW Maintenance Other Maintenance
3 HSE Input HSE Performance Safe Working Manhours (per 30 Jun 11) = 6,417,392, hours Training Hours (Jan Jun 11) = 1,877 hours HSE Output Fatality = 0 Days Away From Work Case (DAFWC) = 0 Recordable Injury Case (RIC) = 1 Traffic Accident = 0 Emergency Drill TRF EMERGENCY DRILL ON MAY 2011
4 Overall Pipeline Condition No pipeline leak No pigging problem No abnormal shut down of supply Switching Bdk Btg pipeline mode: From 3 PL Mode To 3 PL Mode = 4 times From 3 PL Mode To 2 PL Mode = 1 time From 2 PL Mode To 3 PL Mode = 1 time Manual gas venting: 2 times June 8th 2011 on 16 Santan SKG during repair on km (Volume = MMscf) July 2 nd 2011 on 20 CPU Nilam during Repair stuck greasing nipple on HOV 4120D and 4120E 20 CPU Nilam (Volume = MMscf)
5 PT Badak Pipelines Routine Works Program Ytd Q Regular Pigging 10 times 4 times CP monitoring 8 lines 4 lines Valve Greasing 4 lines 4 lines Leak Survey 4 lines No schedule Pigging result No significant debris, sand, etc. retrieved CP Monitoring The pipelines are well protected Valve maintenance (greasing) All greased valves operable
6 Total E&P Indonesie Pipelines Routine Works Program Ytd Q Regular Pigging 3 times 3 times CP monitoring 14 lines 7 lines Valve Greasing 7 lines 6 lines Leak Survey 7 lines 7 lines Pigging g result No significant debris, sand, etc. retrieved CP Monitoring i The pipelines are well protected Valve maintenance (greasing) All greased valves operable Leak Survey No Leak found
7 VICO Pipelines Routine Works Program Ytd Q Regular Pigging 7 times 4 times CP monitoring 20 lines 10 lines Valve Greasing 10 lines 1 line Leak Survey 10 lines 2 lines Pigging result No significant debris, sand, etc. retrieved CP Monitoring i The pipelines are well protected Valve maintenance (greasing) All greased valves operable Leak Survey No Leak found
8 Pertamina Pipelines Routine Works Program Ytd Q Regular Pigging 7 times 3 times CP monitoring 4 lines No schedule Valve Greasing 4 lines 4 lines Leak Survey 4 lines No schedule Pigging result No significant debris, sand, etc. retrieved Including gauging for IPIG preparation Valve maintenance (greasing) All greased valves operable
9 Chevron Pipelines Routine Works Program Ytd Q Regular Pigging 1 time 1 time CP monitoring 2 lines 1 line Valve Greasing 1 line No schedule Leak Survey 1 line No schedule Pigging result No significant debris, sand, etc. retrieved CP Monitoring The pipelines are well protected
10 TI & VICO Pipelines Routine Works Program Ytd Q Pigging result Regular Pigging 4 time 3 times No significant debris, sand, etc. CP monitoring 2 lines No schedule retrieved Valve Greasing 2 lines 2 lines Including IPIG Leak Survey 2 lines 2 lines Valve maintenance (greasing) All greased valves operable Leak Survey No Leak found
11 TI, CVX & VICO Pipelines Routine Works Program Ytd Q Regular Pigging 8 times 4 times CP monitoring 3 lines No schedule Valve Greasing 3 lines 3 lines Leak Survey 3 lines 3 lines Pigging result No significant debris, sand, etc. retrieved Including IPIG Valve maintenance (greasing) All greased valves operable CP Monitoring The pipelines are well protected
12 HSE, External & Security Issues TRF EMERGENCY DRILL ON MAY 2011
13 HSE, External & Security Issues TRF EMERGENCY DRILL ON MAY 2011
14 HSE, External & Security Issues Condensate Thievery at KM 53 Valve station Date: 28 May 2011 Side glass
15 HSE, External & Security Issues +/- 70 m +/- 150 m Map KM 53 Security Post Thick Bushes To PT Ba adak Pump Faciliti es Gate +/- 1 km away Jerry can position Scrubber Facility +/- 150 m Tower Security Post Pipeline e Road Thick Bushes Gate Control Room SDV 5303 To Badak
16 HSE, External & Security Issues KM 53 SCRUBBER PADLOCK SDV-5320
17 HSE, External & Security Issues KM 37 Land Compliance Pak Miskun (P/L Foreman) 2. Pak Herry (Kades Santan Ulu) 3. Pak Arifudin (Anak Pemilik Tanah Sisi Badak) 4. Pak Abu Nawas (anak Pemilik Tanah Sisi Bontang) 5. Pudjio Landowner meetings with PCT KM-37
18 HSE, External & Security Issues Topography p Km NEXT
19 HSE, External & Security Issues KM 37 Land Compliance Back
20 HSE, External & Security Issues KM 37 Land Compliance Back
21 HSE, External & Security Issues Progress Crossing Conveyor PT.BMS Km
22 HSE, External & Security Issues socialization to cover excavation Digging for Electricity cables to house residents at PK
23 HSE, External & Security Issues Socialization Portal Pk Pk Pk Pk
24 HSE, External & Security Issues Install Dwelling Signboard
25 HSE, External & Security Issues Install Road Crossing Signboard
26 HSE, External & Security Issues LIST NEW INSTALL SIGNBOARD LOCATION TOTAL LOCATION TOTAL PK PK PK s/d PK PK PK PK PK PK PK PK PK PK PK PK PK PK s/d PK PK PK PK PK PK PK PK PK PK KM 24 (BDK-BTG) KM (BDK-BTG) KM (BDK-BTG) KM (BDK-BTG) BTG) KM (BDK-BTG) KM (BDK-BTG) KM KM (KM53-SKG) KM (KM 53-SKG) KM (KM53-SKG) KM (BDK-BTG) KM 24 (BDK-BTG) TOTAL =
27 SCHEDULE WORK PROGRAM 2011 PT BADAK
28 PT BADAK Projects Replacement of GOV-VA301-2A VA301 valves (Size 42 ) at 42 CD Receiver 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Done Engineering Procurement Opening tender done Promise delivery 40 weeks (Q2_2011 Q1_2012) Execution Waiting for material (plan Waiting for material (plan to be executed in Q2-2012)
29 PT BADAK Projects Re-certification on 36" AB Badak - Bontang Gas Pipeline 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Supporting documents has been collected Preparation Re-Certification 7 PJIT are already registered, the bidder rating posible only two vendors that will plan on Direct Selection. Execution Plan to be executed on Aug 2011
30 PT BADAK Projects Re-certification on 36" F Badak - Bontang Gas Pipeline 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Supporting documents has been collected Preparation Re-Certification 7 PJIT are already registered, the bidder rating posible only two vendors that will plan on Direct Selection. Execution Plan to be executed on Aug 2011
31 PT BADAK Projects Re-certification on 42" CD Badak - Bontang Gas Pipeline 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Supporting documents has been collected Preparation Re-Certification 7 PJIT are already registered, the bidder rating posible only two vendors that will plan on Direct Selection. Execution Plan to be executed on Aug 2011
32 PT BADAK Projects Re-certification on 42" H Badak - Bontang Gas Pipeline 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Supporting documents has been collected Preparation Re-Certification 7 PJIT are already registered, the bidder rating posible only two vendors that will plan on Direct Selection. Execution Plan to be executed on Aug 2011
33 PT BADAK Projects Intelligent Survey and Digging Verification & Repair 42" CD Badak- Bontang Gas Pipeline. 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Done Engineering Preparation Plan to run Gauging Pig on July, Gauging Pig has arrived Execution plan to be executed in Q4-2011
34 SCHEDULE WORK PROGRAM 2011 TOTAL E&P INDONESIE
35 TOTAL INDONESIE Projects Tanjung Una Rehabilitation (42" Senipah Exposed Pipe) 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Detail design is reviewed Preparation Waiting TI Budget Revision Execution Waiting TI Budget Revision
36 TOTAL INDONESIE Projects Install Valve Status Indicator and Pressure Monitoring Gas Pipeline along Pk to Pk. 35 in Pipeline Telemetry (Pk7, Pk8, Pk29-30, Pk38) 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Site Survey done (Except PK 38) Engineering in progress Preparation Material procurement Waiting for Engineering design Waiting estimate cost from E&C Execution Plan to be executed at Q4 2011
37 TOTAL INDONESIE Projects Cut & Replace 14" NPU-CPU Condensate line 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Cancelled by TI Preparation Cancelled by TI Execution Cancelled by TI
38 TOTAL INDONESIE Projects Intelligent Survey 8" TRF-PK 64 & Digging Verification and Repair Condensate Pipeline 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering i Completed Preparation launcher-receiver has arrived Waiting certificate document from MIGAS Execution Plan to execute at Q4 2011
39 TOTAL INDONESIE Projects Land Acquisition for Dwelling Clearance 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Waiting for discussion Preparation Waiting for discussion Execution Waiting for discussion
40 SCHEDULE WORK PROGRAM 2011 VICO INDONESIA
41 VICO INDONESIA Projects Replacement on 6" HDPE Produce Water Pipeline 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Completed Tender Failed Retender in progress Preparation Execution Plan to execute at Q4-2011
42 VICO INDONESIA Projects Land Acquisition for Dwelling Clearance 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Site survey completed Negotiation In progress Preparation Execution Plan to be executed at Q4 2011
43 SCHEDULE WORK PROGRAM 2011 PERTAMINA
44 PERTAMINA Projects Intelligent t Survey on 16 Santan - SKG 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Completed Preparation Re run Gauging Pig done Waiting mob tools from principal Execution Plan to execute at Q3
45 PERTAMINA Projects Intelligent t Survey on 16 KM 53 - SKG 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Completed Preparation Re run Gauging Pig done Waiting mob tools from principal Execution Plan to execute at Q3
46 PERTAMINA Projects Digging i verification and repair 16" STN-SKGSKG 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Waiting IPIG result Waiting IPIG result Preparation Execution Plan to execute at Q3
47 PERTAMINA Projects Digging i verification and repair 16" KM53-SKG 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Waiting IPIG result Waiting IPIG result Preparation Execution Plan to execute at Q3
48 PERTAMINA Projects Relocate SDV-5303/5304/5305 Equipped with Over-ride ride System, and Install Cold Vent Facilities at KM-53 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Completed Waiting for BDV PO Cancelled Retender on Q3 Procurement Execution Waiting for Instrument Installation
49 SCHEDULE PROJECT WORKS COMMON PROJECT 2011
50 Common Project 5th Year Sponsorship of Oppinet 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Design by OPINET Team completed Site visit done Preparation Execution Plan to execute at Q2-Q4 2011
51 Common Project Landslide mitigation/rehabilitation (Base on Re-assessment Result) 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering g Final report LAPI ITB Completed Design and Calculation - In Progress Preparation Soil test - Done Design Drawing In progress Plan to execute on Q3,Q4 Execution
52 Common Project Riverbank Rehabilitation (Pk.8 & Pk30) 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering PK.8 Design Calculation in progress PK. 30 Drawing completed Preparation Pk.8 & PK 30: collecting topography data Execution Plan to execute on Q3-2011
53 Common Projects Inclinometer Installation ti 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Done Engineering PFCAR approved Preparation Progress Direct Award to PT Reka Elektra Execution Plan executed in Q3
54 Common Projects Piezometer Installation ti 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Done Engineering PFCAR approved Preparation Progress Direct Award to PT Reka Elektra Execution Plan executed in Q3
55 Done Common Projects Various Tools & Equipment Purchase 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering i Tender in progress Preparation Delivery Promised delivered in Q4 2011
56 PROGRESS BRIDGE KM. 37 BADAK BONTANG
57 PROGRESS BRIDGE KM. 37 BADAK BONTANG
58 SCHEDULE PROJECT WORKS COMMON SPECIFIC PROJECT 2011
59 Common Specific Project Intelligent Survey 8" Old Badak - Santan & digging verification Condensate Pipeline 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Completed Re run Gauging Pig Done Preparation Execution Run EGP July 12, 2011 Run CDP July 13, 2011
60 Common Specific Project Intelligent Survey 8" New Badak - Santan & digging verification Condensate Pipeline 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Completed Preparation Re run Gauging Pig Done Execution Run EGP June, Run CDP June, ) Waiting for Final Report
61 Common Specific Project Replace main valve 20 Handil Nilam at Pk 41 (HOV 4120A/E/F) 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Completed Preparation Material Procurement in progress Direct award to PT Alphacon Execution Plan to execute on Q4 2011
62 Common Specific Project Repair exposed pipe of 20" Handil - Nilam 1 st Quarter 2 nd Quarter 3 rd Quarter 4 th Quarter Engineering Completed (by TI) Preparation Completed (by TI) Execution Completed (by TI)
63 Road and ROW Maintenance Repair P/L Road Pk Pk Km Km
64 Road and ROW Maintenance Repair of P/L Road At Km 26 Km 36 Bdk - Btg Km Km
65 Road and ROW Maintenance Progress Grass Cuting Pk
66 Road and ROW Maintenance Progress Grass Cuting Around KM 53 Station
67 Road and ROW Maintenance Open Drain Pk 1.4 Pk 7 Km Km
68 Road and ROW Maintenance Maint. Open Drain Kp 20 Kp 21 Km Km
69 Road and ROW Maintenance ROW Maintenance Drainage and Road Km 27 Badak - Bontang Km Km Km
70 Other Maintenance Repair 16 Santan km
71 Other Maintenance
72 Other Maintenance
73 Other Maintenance
74 Other Maintenance
75
76 SWITCHING PIPELINE MODE ACTIVITIES 1. May 19, 2011: Switching from 3 P/L mode (2X AB) to 3 P/L mode (2x36 + 1x42 CD) (36 F Online & 42 H Idle) due to rate from NPU dropped by 580 mmscfd. 2. June 17, 2011: Switching from 3 PL Mode (2x42 +1X36 AB) to 3 P/L mode (2x H)(36 F Online and 42 CD Standby) Due to rate from CPU dropped by 200 mmscfd 3. June 18,2011 : Switching from 3 PL Mode (2x36 +1X42 H) to 2 P/L mode (2X42 )(36 AB Standby and 36 F Standby) ) Due to rate from Sisinubi dropped by 418 mmscfd 4. June 23, 2011 : Switching from 2 PL Mode (2X42) to 3 P/L mode (2X42 +1X36 AB) (36 F Standby) ) Due to rate from Tatun Increased by 720 mmscfd 5. June 28,2011 : Switching from 3 PL Mode (2x42 +1X36 AB) to 3 P/L mode (2x CD)(36 F Online and 42 H Standby) Due to rate from Sisinubi dropped by 450 mmscfd - In Line with Function Test 42 H 6. June 29,2011 : : Switching from 3 PL Mode (1x42 CD +2X36 AB) to 3 P/L mode, g ( ) / (2x H)(42 CD Standby and 42 H Online) Due to Function Test line 42 CD
Pipeline engineer competency standards list: onshore sector
Pipeline engineer competency standards list: onshore sector ID Competency area/competency Gen Des Cons Ops Level General engineering GE001 Engineering degree in a relevant discipline x Core GE002 Pipeline
More informationIn the section from valve site No 13 to the place of the end of works Lithuanian-Polish border (~37 km)
The components of the price for procurement construction works for the part of gas interconnection Poland-Lithuania in the territory of the Republic of Lithuania are as follows: 1. 1.1. 1.1.1. Construction
More informationCollections Exam Need to Know Criteria
Equipment Operation & Evaluation Class 1 Class 2 Class 3 Class 4 Operate drives X X X X Operate electronic testing equipment X X X X Operate hand and power tools X X X X Operate heavy equipment X X X X
More informationApplication for Underground Pipeline Crossing or Longitudinal of Railroad Property and or Track
Carload Express, Inc. Right-of-Way Manager, 519 Cedar Way, Bldg 1, Suite 100 Oakmont, PA 15139 Application for Underground Pipeline Crossing or Longitudinal of Railroad Property and or Track Section 1
More informationMount Pleasant Waterworks. Cross-Connection Control Program Guidelines October 2010
Mount Pleasant Waterworks Cross-Connection Control Program Guidelines October 2010 1 PREFACE The purpose of this policy is to protect the public water supply from the possibility of contamination. The
More informationMinistry of Transportation and Infrastructure jurisdiction (337 km) Federal Parks Canada jurisdiction (103 km)
nfrastructure jurisdiction (337 km) HGHWAY 1 KAMLOOPS TO ALBERTA FOUR-LANNG PROGRAM Welcome Thank you for attending this community engagement on the Trans- Canada Highway 1 West Project, part of the Highway
More informationData and Voice Line Installation Procedure. Revision History
Data and Voice Line Installation Procedure OBJECTIVE SCOPE Data and Voice Line Installation Procedure Information Services Technical Revision History Date Detail of Change Change Made By 1/14/11 Revision
More informationContinuing Professional Development (CPD)
Government of Nepal Continuing Professional Development (CPD) Rural Access Programme (RAP) Phase 3 November 2014 Continuing Professional Development, 1. What is Continuing Professional Development?...
More informationThe Chuandongbei Gas Project
The Chuandongbei Gas Project Dr. Min Chen Vice President Chevron China Energy Company September 2016 Project Overview 30-year Production Sharing Contract (PSC) signed between Unocal East China Sea, Ltd.
More informationA Look Ahead: The RedVector Product Roadmap
A Look Ahead: The RedVector Product Roadmap Agenda Overview 2016 Highlights 2017 YTD Coming Soon Q&A The RedVector Product Roadmap OVERVIEW RedVector Product Brands Architecture Basic Workplace Skills
More informationEnvironmental Management Procedure (EMP)
Environmental Management Procedure (EMP) 4.4.6.14.1 Subject: Aboveground Storage Tank (AST) Management 1. Purpose and Policy: A. Purpose: This policy is to outline and ensure compliance with the regulatory
More informationProgram Management Office January, 2012
Program Management Office January, 2012 Clarify the Project Delivery Process (PDP) What is it? Why did it change? How were the changes determined? How was it approved? Show you where to get guidance Answer
More informationWATER TELEMETRY SYSTEM
WATER TELEMETRY SYSTEM v1.04 1 SkyΜeter Hydro edition (SM-HL) The SkyMeter is installed in the water supply and offer the following capabilities: Latest technology Highly accurate metering R160 Feature
More informationTVA Response to the Fukushima Event and Lessons Learned from Recent Natural Disasters
TVA Response to the Fukushima Event and Lessons Learned from Recent Natural Disasters SOUTHERN LEGISLATIVE CONFERENCE July 17, 2011 Agenda Centralized Response Center What We Have Done Key Initiatives
More informationSCADA System Specification. Vantage Pipeline Project # May 2013
SCADA System Specification Vantage Pipeline Project #201011 May 2013 Revision 0 Issued for Approval May 24, 2013 TABLE OF CONTENTS REVISION HISTORY:...2 1 PROJECT OVERVIEW...3 2 SCOPE AND PURPOSE...4 3
More informationAllegro Energy Consulting
The Oil Pipeline Industry Had an Idea... Learning from PPTS 1999-2007 Understanding Hazards Cheryl J. Trench Consequences President Improving Performance Allegro 0 Spills 0 Deaths A Presentation to Pipeline
More informationADDENDUM #2 TO REQUEST FOR PROPOSAL (RFP) #2252 Institutional Network Service, Data Center Co-location Service, and High-Speed Internet Service
CITY OF CONCORD, CALIFORNIA March 13, 2013 ADDENDUM #2 TO REQUEST FOR PROPOSAL (RFP) #2252 Institutional Network Service, Data Center Co-location Service, and High-Speed Internet Service NOTICE TO PROPOSERS
More informationNOTE ON PERFORMANCE TESTING
NOTE ON PERFORMANCE TESTING Performance Profile Sheet(s) are included in a format that can be easily photocopied for each trainee. This examination is designed to measure competency in the tasks taught
More informationEnhanced Pipeline Graphics File
Enhanced Pipeline Graphics File Layout Document October 2017 Enhanced Pipeline Graphics File October 2017 Published by Alberta Energy Regulator Suite 1000, 250 5 Street SW Calgary, Alberta T2P 0R4 Telephone:
More informationINTEGRATED MAINTENANCE & INTEGRITY SOLUTIONS
INTEGRATED MAINTENANCE & INTEGRITY SOLUTIONS Maintaining and Improving Integrity of Corrosion Monitoring Access Fittings on Ageing Assets Alan Taylor, 13 th June 2017 ICR. INTEGRATED MAINTENANCE & INTEGRITY
More informationMetro Mot opo'"'" T""''"""~" '"'"""''
'"''"'''''c.,.., Metro Mot opo'"'" T""''"""~" '"'"""'' One Gateway Plaza Los Angeles, CA 90012-2952 2 13.922.2000 Tel metro. net 40 SYSTEM SAFETY AND OPERATIONS COMMITTEE JUNE 19, 2014 SUBJECT: ACTION:
More informationWireless Sensor Communication Systems for Bridge Monitoring
Wireless Sensor Communication Systems for Bridge Monitoring e-community Division, Public Sector 1, NTT DATA Corporation Yuji Ishikawa Copyright 2016 NTT DATA Corporation Copyright 2015 NTT DATA Corporation
More informationWater Company Lay Application
WCL FORM 2018/3494 Water Company Lay Application SECTION A CONTACT DETAILS Preferred method of contact: Post Email DEVELOPER DETAILS Company name: For the attention of: Property name / number: Street:
More informationOverview of PECO s Distribution Integrity Management Plan
Overview of PECO s Distribution Integrity Management Plan PUC Gas Safety Seminar September 8, 2016 David Bonner, PE Robert Ridgeway, PE Agenda PECO Distribution System Overview DIMP Pillar #1 DIMP DIMP
More informationUE CONNECTION APPLICATION - POLE to PIT (Underground Electricity Supply)
Phone 1300 131 689 Business Hours 8:00AM 5:00PM United Energy ABN 70 064 651 029 Scan & Email undergroundsupply@ue.com.au Attn: Customer and Market Operations PO Box 449 Mount Waverley VIC 3149 Thank you
More informationWORKPAPERS TO PREPARED DIRECT TESTIMONY OF DAVID BUCZKOWSKI ON BEHALF OF SOUTHERN CALIFORNIA GAS COMPANY BEFORE THE PUBLIC UTILITIES
Application of SOUTHERN CALIFORNIA GAS ) COMPANY for authority to update its gas ) requirement and base rates ) effective January 1, 2019 (U 904-G) ) Application No. 17-10- Exhibit No.: (SCG-11-CWP) WORKPAPERS
More information2nd High Elevation Pressure Loss. Low Pressure Incident at Bryant Street Pumping Station
2nd High Elevation Pressure Loss Low Pressure Incident at Bryant Street Pumping Station Background DC Water buys water from Washington Aqueduct From pump stations, water is distributed to different elevations
More informationGENERATOR ADDENDUM TO MAGNOLIA GARDENS ASSISTED LIVING COMPREHENSIVE EMERGENCY MANAGEMENT PLAN
Contact Person: Philip McCollum - Administrator Magnolia Gardens Assisted Living AL Lic# 10314 3800 62 nd Avenue North Pinellas Park, FL 33781 Phone: 727.489.6440 GENERATOR ADDENDUM TO MAGNOLIA GARDENS
More informationSystems role in defence procurement
Systems role in defence procurement The MoD has embarked on the Future Rapid Effect System (FRES) programme to develop the next generation of medium-weight armoured vehicles for the Military. With procurement
More informationRapid, Low-cost Elevator and Escalator Modernization Services that Ensure Safety and Security
Hitachi Review Vol. 66 (2017), No. 3 207 Featured Articles I Rapid, Low-cost Elevator and Escalator Modernization Services that Ensure Safety and Security Tatsunori Takahashi Yasuhiro Takahashi Toshiaki
More informationElectrification - Infrastructure Construction activities in Segment 2:
Peninsula Corridor Electrification Project (PCEP) Q1 Quarterly Update #12 July 1 September 30, 2017 JPB Board Meeting November 2, 2017 Agenda Item # 8a Electrification - Infrastructure Construction activities
More informationTraverse City Asset Management Plan
Utilities and Public Services Larry LaCross, GISP, Asset Management/GIS Analyst Traverse City Department of Public Services Introduction About Traverse City (TC) TC Assets Department of Public Services
More informationRequest for Quotation Amendment #: 1
Request for Quotation Amendment #: 1 Solicitation Number Printed Issued Procurement Officer Phone E-Mail Address 080515-962-36505-08/14/15 08/11/15 08/11/15 Robert E. Tyner, C.P.M. 843-574-6279 Robert.tyner@tridenttech.edu
More informationGLOBAL EXPERIENCE LOCAL KNOWLEDGE
GLOBAL EXPERIENCE LOCAL KNOWLEDGE GLS MONITORING, A JOINT VENTURE BETWEEN GEOMOTION AND LAND SURVEYS CHRYSTALISES MAJOR SYNERGIES BETWEEN THE 2 ENTITIES Geomotion Australia, with a global supply chain
More informationIAGC - OGP Joint HSE & Security Forum
IAGC - OGP Joint HSE & Security Forum Long Term Field Trial Remote Passive Acoustics Monitoring Visual and Infra Red Camera Imaging Bernard Padovani, Seiche Measurements Content Introduction Objectives
More informationGetting the Most from Your SCADA Data
Getting the Most from Your SCADA Data Standards Certification Education & Training Publishing Conferences & Exhibits Speaker: Emile Richard 2015 ISA Water / Wastewater and Automatic Controls Symposium
More informationAnnual Training plan 2018
Annual Training plan 2018 Leadership,, HR, Creativity, Secretary Courses Sr. No. Course Name Date Venue Fees U.S $ January 1. Time & Stress 7-11/1/2018 Abu Dhabi 2600 2. Legal Writing Skills 7-11/1/2018
More informationNerc Operator Certification Training
Nerc Training Free PDF ebook Download: Nerc Training Download or Read Online ebook nerc operator certification training in PDF Format From The Best User Guide Database Aug 1, 2012 - NERC System Program
More informationCouncil, 26 March Information Technology Report. Executive summary and recommendations. Introduction
Council, 26 March 2014 Information Technology Report Executive summary and recommendations Introduction This report sets out the main activities of the Information Technology Department since the last
More informationBaseline Bridge Crossing. Priorities Committee Meeting
Baseline Bridge Crossing Priorities Committee Meeting June 14, 2016 1 Unparalleled Asset Footprint Largest Energy Infrastructure Company in North America Over 12,000 employees in Canada and the U.S. $18.2
More informationPREMISES POLLUTION LIABILITY
Beacon Hill Associates, Inc PO Box 1532 Charlottesville, VA 22902 Toll Free: 800) 596-2156 Fax: 434) 979-8964 info@b-h-a.com PREMISES POLLUTION LIABILITY APPLICATION PREMISES POLLUTION LIABILITY COVERAGE
More informationAccord Builder. User Guide
User Guide Document: V 3.6 User Guide R01 V3.6 User Guide R01 Page 1 of 110 Table of Contents 1 Introduction... 7 2 General Summary and Definitions... 8 2.1 Accord Platform and Plant... 8 2.2 PLC Control
More informationSTEVE TSHWETE LOCAL MUNICIPALITY
DEPARTMENT : PARKS AND RECREATION POST TITLE : Horticulturist POST LEVEL : 08 SALARY SCALE : R145 086, R152 457, R160 224p.a. REQUIREMENTS : Tertiary qualifications in Horticulture (Environmental Science)
More informationSpecifications for Static and Dynamic Structural Testing System
Specifications for Static and Dynamic Structural Testing System ANNEXURE-1 S No. Particulars Technical Requirement 1 Servo-hydraulic Actuators 1. Application: Static, Dynamic and Fatigue 2. Quantity: 2
More informationHow Cloud-based technology helped save the equivalent of 50 million bottles of Evian
How Cloud-based technology helped save the equivalent of 50 million bottles of Evian Presented by: Mark Nicol Senior Director International Division, Echologics Founded in 2003 in Ontario, Canada by a
More information3-D Modeling Implementation
3-D Modeling Implementation Presented January 31, 2013 Douglas Townes FHWA Resource Center WORKFLOW FOR ELECTRONIC DATA TRANSFER WHEN USING AMG IN CONSTRUCTION Charles Jahren, PhD Iowa State University
More informationAP1000 European 1. Introduction and General Description of the Plant Design Control Document
AP1000 European 1. Introduction and General Description of the Plant Design Control Document 1.7 Drawings and Other Detailed Information 1.7.1 Electrical and Instrumentation and Control Drawings Instrument
More informationDIT/BPR&BTD/OA/1206/
UCO BANK Department of Information Technology Request for Proposal (RFP) For Building of Data Centre Infrastructure for non-cbs servers at 6th Floor, HO DIT (Re-tendering) RFP Ref No: DIT/BPR&BTD/OA/1206/2018-19
More informationADDENDUM NO. 02 INVITATION NUMBER:
ADDENDUM NO. 02 INVITATION NUMBER: 160190 DATE: TO: PROSPECTIVE BIDDERS REFERENCE: B STREET/NEW JERSEY AVENUE TRUNK SEWER REHABILITATION AND CLEANING PHASE 1 THIS PAGE IS INTENTIONALLY LEFT BLANK DISTRICT
More informationOperating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage
Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling
More informationContinuously Operating GPS Reference Network. Jim Waters, PE, RLS Assistant Director, Design Division
Continuously Operating GPS Reference Network Jim Waters, PE, RLS Assistant Director, Design Division TDOT began discussions internally about a possible Continuously Operating Reference Network in 1999
More informationHamlet Board Meeting. August 27/18. 3:00 pm RM office
Hamlet Board Meeting August 27/18 3:00 pm RM office Present: Larry Bedel, Jim Toth, Carla Taylor, Dan Dukart (arrived 3:45), Nicole Keith (excused at 4:00) 1. Call to Order Larry at 3:04 pm 2. Approval
More informationDRAFT USAG-UR-SGREG DECEMBER 2011 REVISION 0
ALASKA PIPELINE PROJECT RESOURCE REPORT 1 GENERAL PROJECT DESCRIPTION APPENDIX 1E FERC Docket No. PF09-11-000 USAG-UR-SGREG-000002 DECEMBER 2011 REVISION 0 APPENDIX 1E TYPICAL DRAWINGS ALASKA PIPELINE
More informationPIG REPLACEMENT PARTS
PIG REPLACEMENT PARTS C - Scraper 2-14 Pg. 7-2 C - Scraper 16-48 Pg. 7-3 C - Sealer 3-14 Pg. 7-4 C - Sealer 16-48 Pg. 7-5 C - Guide 3-14 Pg. 7-6 C - Guide 16-48 Pg. 7-7 JC - Jetted 2-14 Pg. 7-8 JC - Jetted
More information2.03 ADGAS. Company. P r ofile. Vision: Mission: About ADGAS
Oil & Gas Directory Middle East - 2013 15 Vision: we will play a key role in the LNG and natural gas industry, creating wealth and value, implementing the National Energy Strategy and serving our valued
More informationAMERICAN WATER WORKS ASSOCIATION 2013 DIVISION ANNUAL REPORT TO TEC
AMERICAN WATER WORKS ASSOCIATION 2013 DIVISION ANNUAL REPORT TO TEC Division Name: Distribution & Plant Operations (DPOD) Chair: Charly C. Angadicheril Vice Chair: Ahmad Habibian When and where has the
More informationQLC(Y) SERIES EMERGENCY FIRE FIGHTING WATER SUPPLY EQUIPMENT
As we are constantly endeavouring to improve the performance of our equipment. The company reserves the right to make alteration from time to time and equipment differ from that detailed in this brochure.
More informationFacilities User Guide. April 2017
April 2017 Contents Facilities User Guide 1 April 2017 1 What is EAS? 1 EAS support 1 EAS Administrator 1 Facilities business support 1 Resources business support 1 DDS support 1 Getting started 2 EAS
More informationCYBERSECURITY IMPLEMENTATION FOR THE MARINE AND OFFSHORE INDUSTRIES
GUIDE FOR CYBERSECURITY IMPLEMENTATION FOR THE MARINE AND OFFSHORE INDUSTRIES ABS CyberSafety TM VOLUME 2 SEPTEMBER 2016 NOTICE NO. 2 June 2018 The following Changes were approved by the ABS Rules Committee
More informationBorgonovo Giorgio,Contini Alessio, Locatelli Livio, Ramelli Enzo. Golder Associates (Milan - Italy)
A comprehensive monitoring system of mechanized tunnelling in urban area Automated control of geotechnical measures, topographic surveys, rail tracks geometry and TBM data Borgonovo Giorgio,Contini Alessio,
More informationNational Certificate in Infrastructure Works (Infrastructure Pipelaying Technician) (Level 3) Level 3
NZQF NQ Ref 1282 Version 5 Page 1 of 9 National Certificate in Infrastructure Works (Infrastructure Pipelaying Technician) (Level 3) Level 3 Credits 114 This qualification has been reviewed. The last date
More informationUniversity Information Systems. Administrative Computing Services. Contingency Plan. Overview
University Information Systems Administrative Computing Services Contingency Plan Overview Last updated 01/11/2005 University Information Systems Administrative Computing Services Contingency Plan Overview
More informationThis qualification is expiring. The last date to meet the requirements is 31 December 2010.
NQF Ref 0881 Version 2 Page 1 of 12 National Diploma in Civil Engineering Level 6 Credits 410 This qualification is expiring. The last date to meet the requirements is 31 December 2010. Purpose The National
More informationMAZANDARAN PROCUREMENT PLAN (FIRST YEAR)
losure Authorized Public Disclosure Authorized Public Disclosure Authorized Public Disclosure Authorized Sl. # Tender Number 2 SW2 3 SW3 5 SS2 6 SS3 DESCRIPTION 1.4 & 1.5 -Main Pipes 1&2 Sari Wastewater
More informationEX- Documentation VA 450 / VA 452. thermal mass flow sensor
EX- Documentation VA 450 / VA 452 thermal mass flow sensor This document contains important information for the installation and operation of the flow sensor in explosive environments. Please read the
More informationCustomer Responsibilities
For Research Use Only. Not for use in diagnostic procedures. Thank you for purchasing the Agilent G5590A BenchCel Workstation. To get you started and to assure a successful and timely installation, please
More informationThe Edge Training Portfolio
The Edge Training Portfolio www.gen2.ac.uk 1 The Edge Contents The Edge 3 We are delighted to introduce The Edge, a new 8.5M funded project which runs until July 2018 and focusses on: Training Programmes
More informationThe City of St. Petersburg (City) initiated
FWRJ Remote Facility Condition Inspections and Subsequent Integration into the City of St. Petersburg s Asset Management Program Laura Baumberger, Robert Labrie, and Rebecca Overacre The City of St. Petersburg
More informationPROJECT MANAGEMENT PROCESS ENGINEERING & PSA FRONT END DEFINITION EXECUTION PLANNING FID COST ESTIMATING ENGINEERING MANAGEMENT & QA
Rev B May 16 2015 PROJECT MANAGEMENT PROCESS ENGINEERING & PSA FRONT END DEFINITION EXECUTION PLANNING FID COST ESTIMATING ENGINEERING MANAGEMENT & QA PROCUREMENT & EXPEDITING MECH. COMPLETION PLANNING
More informationISO 50001/SEP. Superior Energy Performance at Schneider Electric. Design the Strategy Deliver Efficiency Sustain Results
ISO 50001/SEP Superior Energy Performance at Schneider Electric Design the Strategy Deliver Efficiency Sustain Results Schneider Electric the global specialist in energy management Balanced geographies
More informationSlide 1. Slide 2. Voisey s Bay Project Update
Slide 1 Slide 2 Voisey s Bay Project Update October 2003 Slide 3 Presentation Overview Project Components Mine and Concentrator Exploration Argentia Hydromet R&D Innovation Centre Expenditure Forecast
More informationnote on Performance Testing
note on Performance Testing Performance Profile Sheet(s) are included in a format that can be easily photo cop ied for each trainee. This examination is designed to mea sure competency in the tasks taught
More informationPort Moresby Power Grid Development Project.
Environmental Monitoring Report Semi-annual Report January 2017 Port Moresby Power Grid Development Project. Prepared by PNG Power Limited for the Asian Development Bank. This Semi-annual Environmental
More informationSPECIFICATIONS SYRINGE SAMPLER KZ-31W Higashimotomachi, Kokubunji, Tokyo , Japan. No E Printed in Japan
SPECIFICATIONS SYRINGE SAMPLER KZ-31W 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan No. 14018E 15-07 Printed in Japan Outline The syringe sampler KZ-31W serves to supply a controlled amount
More informationSmartSoft AES Operator s Guide
SmartSoft AES Operator s Guide Part No. 702064 Rev. A Physical Electronics USA, PHI, SMART-Tool, SmartSoft, MultiPak and Watcher are trademarks of ULVAC-PHI, Inc. All other trademarks are the property
More informationnuclearsafety.gc.ca Implications of the Fukushima Daiichi Accidents for the New Builds Design Requirements in Canada
Implications of the Fukushima Daiichi Accidents for the New Builds Design Requirements in Canada R.P. Rulko () IAEA Technical Meeting on Evaluation of Nuclear Power Plant Design Safety in the Aftermath
More informationNational Certificate in Gas Industry (Gas Distribution) (Level 2)
NZQF NQ Ref 1020 Version 5 Page 1 of 10 National Certificate in Gas Industry (Gas Distribution) (Level 2) Level 2 Credits 49 This qualification has been reviewed. The last date to meet the requirements
More informationGas Infrastructure Europe. Security Risk Assessment Methodology
Gas Infrastructure Europe Security Risk Assessment Methodology May 2015 Introduction Gas Infrastructure Europe (GIE) is an association representing the interests of European natural gas infrastructure
More informationEmergency Support Function (ESF) #14b: UTILITIES: Potable Water. ESF Activation Contact: Cornell Facilities Customer Service (607)
Emergency Support Function (ESF) #14b: UTILITIES: Potable Water ESF Activation Contact: Cornell Facilities Customer Service (607)255-5322 Primary Department I. Purpose: Cornell IPP: Utilities and Energy
More informationIf you have any questions regarding this survey, please contact Marcell Reid at or Thank you for your support!
ABBVIE GLOBAL SUPPLIER SUSTAINBILITY PROGRAM Annual Supplier Sustainability As an important supplier to AbbVie, we would like to document and assess your company s activities and progress regarding sustainability
More informationInstallation Service. 1.0 Executive Summary. Factory Trained Technician Train Customer Support Staff On Basic Operation Of The Equipment
Installation Service Statement of Work Start-up Service for Cooling Start-up - 1 - Service for Cooling Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0
More informationThe standard base asset life used in the renewal programme and asset valuation for facility assets (major components) are shown in the table below:
7.3.6 Facilities Background Plant is defined as asset components that pump, store or treat water. Key components include: Pumping stations - pumping of water to within the reticulation Treatment plants
More informationNew Receipt Point Pre Inspection Checklist
New Receipt Point Pre Inspection Checklist The following checklist items are required to be completed prior to booking an initial inspection. Once this checklist has been completed, please fax a copy,
More informationASSET INTEGRITY & CORROSION CONTROL.
1 ASSET INTEGRITY & CORROSION CONTROL 2 THE VALUE OF EXCELLENCE MEARS TURNKEY SERVICES Mears Integrity Solutions provides turnkey prevention, inspection, and remediation services. Corrosion prevention
More informationTABLE OF CONTENTS. Section 2.0 GENERAL PLAN REQUIREMENTS 05/2011. Section 100 ROADWAY DESIGN 01/2016
TABLE OF CONTENTS The City Standard Manual was revised in 2010. Please see dates in the revised column for details that have been modified after 2010. PART 1 - DESIGN STANDARDS Section 1.0 ENGINEERING
More informationCity of San Antonio Utilizing Advanced Technologies for Stormwater System Mapping and Condition Assessments
City of San Antonio Utilizing Advanced Technologies for Stormwater System Mapping and Condition Assessments Prepared for: 2017 ESRI Users Conference Prepared by Noelle Gaspard, PE, GISP, CFM July 12,2017
More informationMECHANICAL CONTRACTORS ASSOCIATION OF AMERICA, INC. CLEANROOM PIPING AND PROCEDURES BASIC CONSIDERATIONS
BASIC CONSIDERATIONS For the mechanical contractor, cleanroom construction involves the installation of high purity piping which support an ultra clean environment. This involves extremely stringent requirements
More informationDue Diligence Checklist #20
INDEX Page Summary Implementation of TTC & Coroner s Jury Recommendations...i Coroner s Jury Recommendations... 1 Signals Design... 4 Note: This updated checklist contains updates to recommendations that
More information18 th National Award for Excellence in Energy Management. July 27, 2017
18 th National Award for Excellence in Energy Management July 27, 2017 ICICI Bank, Data Centre, August Hyderabad 30 & 31, 2017 ICICI Bank - Revolution in Digital Banking Over 100,000 Digital POS in 4 months
More informationAlberta One-Call Online Request Process
Alberta One-Call Online Request Process Requesting routine locates online is a convenient way for excavators to submit their request at their convenience. Ticket confirmations are sent via email once processed.
More informationAdvances in Telemetry. Finding out what is really going on in your system
Advances in Telemetry { Finding out what is really going on in your system Dr. David Mundie President of High Tide Technologies Involved in telemetry design for over 30 years Space, Air and Ground Telemetry
More informationA Data Model for Distributed Data Management. Matt Erker, Phil Lidov
A Data Model for Distributed Data Management Matt Erker, Phil Lidov Problem Statement Transportation planning, from statewide long range planning through environmental assessment of individual improvements,
More informationOverview of the USGS Plan for Quality Assurance of Digital Aerial Imagery
Overview of the USGS Plan for Quality Assurance of Digital Aerial Imagery Presented to MAPPS Conference March 14, 2006 U.S. Department of the Interior U.S. Geological Survey Outline Introduction Background
More information# 7. Date of Meeting: March 13, 2018 BOARD OF SUPERVISORS FINANCE/GOVERNMENT OPERATIONS AND ECONOMIC DEVELOPMENT COMMITTEE ACTION ITEM SUBJECT:
BOARD OF SUPERVISORS FINANCE/GOVERNMENT OPERATIONS AND ECONOMIC DEVELOPMENT COMMITTEE ACTION ITEM Date of Meeting: March 13, 2018 # 7 SUBJECT: ELECTION DISTRICT: Contract Award/Roadway and Civil Design
More informationCommunity Advisory Committee. June 5, 2017
Community Advisory Committee June 5, 2017 1 Today s Topics Call to Order/Introductions Approval of Minutes Project Overview Traffic Signal Coordination 60% Plans Update Advanced Construction: Bassett Creek
More informationCreate an Animal Use Form
Overview Principal Investigators (PIs) and Lab Personnel with the role of Protocol Editor or Authorized Signer can request the purchase or transfer of animals and report animal acquisitions or deliveries
More informationi. Prepare an SPCC plan in accordance with good engineering practices. (40 C.F.R )
SPCC PLANS To prepare a Spill Prevention Control and Countermeasure (SPCC) plan in accordance with U.S. Code of Federal Regulations, Title 40, Part 112 (40CFR112), you must: i. Prepare an SPCC plan in
More informationBelize s Climate Resilient Investment Plan. Prioritised Investment Plan for Climate Readiness
Belize s Climate Resilient Investment Plan Prioritised Investment Plan for Climate Readiness Belize in its regional context 2 Background Long Low-lying coastline Over a thousand small islands Largest barrier
More informationBangladesh Urban Resilience Project (P149493)
Public Disclosure Authorized SOUTH ASIA Bangladesh Social, Urban, Rural and Resilience Global Practice Global Practice IBRD/IDA Investment Project Financing FY 2015 Seq No: 8 ARCHIVED on 30-Dec-2018 ISR35201
More informationITD SERVER MANAGEMENT PROCEDURE
ITD SERVER MANAGEMENT PROCEDURE PURPOSE This procedure ensures the operation and maintenance of all ITD servers in a safe and effective fashion. This is achieved by the routine monitoring and timely update
More information