LINE UP LINE UP (RT) ( RCUP75AUZ / 50Hz ) Products Series RCUP-AUZ
|
|
- Tamsyn Small
- 5 years ago
- Views:
Transcription
1
2 Hitachi screw chiller unit widely used for air conditioning and industrial purposes Newly released, equipped with a new screw compressor realizing drastic energy saving and great functionality ( RCUP75AUZ / 50Hz ) LINE UP LINE UP (RT) Products Series RCUP-AUZ
3 Designed to reduce the impact on the environment compared to R22 units 100% 65% In the 7th meeting of montreal protocol contracting states (Vienna) in 1995, it was decided to abolish HCFC's by 2020, although HCFC's have much lower ozone destruction coefficient than CFC's. Thus R22 (HCFC22) used for air conditioners must be replaced by some alternative refrigerant. 35% 10% 0.5% 3
4 Hitachi's new screw compressor In Hitachi s new screw compressor, inside leakage is decreased to the minimum with the higher-accuracy rotor processing technology. By using cyclone oil separation system other than demister oil separation system, oil separation efficiency is largely improved. Also, heat transmission efficiency is greatly improved, pressure loss is reduced by smaller oil flow into the cooling pipe, sealing ability is improved by the changed chiller oil and chilling efficiency is substantially improved. As a result COP is increased to 25%, the largest number in the series. 5
5 Hitachi's energy-saving technology Slide valve Bypass gas Low pressure gas Pd Ps Suction gas Rotor SV1 SV3 SV2 Slide valve Bypass gas High pressure oil Low Pressure gas Top class high COP Pd Ps Suction gas Rotor SV1 SV3 SV2 High pressure oil 125% UP!! 20% DOWN!! 7
6 Other characteristics System application *
7 General data Model Continuous Control Type R407C kw* 1 USRT* 1 kcal/h* 1 Btu/h* 1 kw* 1 USRT* 1 kcal/h* 1 Btu/h* 1 Height Width Depth Standard accessories Optional accessories
8 Dimensional data unit : mm unit : mm Chilled Water Inlet (3"Victaulic Joint : 1,050 1,050 TYPICAL WATER PIPING Chilled Water Inlet (3"Victaulic Joint : Chilled Water Outlet (3"Victaulic Joint : 1,285 Expansion Valve Field Piping ( 3" Victaulic Joint ( Water Strainer (20 Mesh : 89.1 HITACHI Standard 3" Victaulic Joint ( Plate Heat-Exchanger Chilled Water Outlet (3"Victaulic Joint : View from P Air Outlet 1,285 Expansion Valve Air Side Heat-Exchanger 2,150 Water Cooler Air Outlet Earth Terminal (M10) 30 (1,840) 30 Magnetic Switch Box Mounting Holes (4-26) 100 (1,700) Air Side Heat-Exchanger Check Valve Screw Compressor Rigging Holes (4-50) NOTES: 1.Provide a 20 mesh water strainer at the chilled water inlet. The 20 mesh strainer is available by Hitachi as an optional accessory. 2.Support the water pipes with stay not to give the weight of water pipes directly to the unit. 3.Specifications in this drawing are subject to change without notice,in order that Hitachi may bring the latest innovations to our customers. 2,150 P Water Cooler Earth Terminal (M10) 30 (1,840) 30 NOTES: 1.Provide a 20 mesh water strainer at the chilled water inlet. The 20 mesh strainer is available by Hitachi as an optional accessory. 2.Specifications in this drawing are subject to change without notice, in order that Hitachi may bring the latest innovations to our customers. Magnetic Switch Box Mounting Holes (8-26) 100 1,800 Check Valve Screw Compressor (1,800) 100 5,700 unit : mm 1,050 Chilled Water Inlet (3"Victaulic Joint : Chilled Water Outlet (3"Victaulic Joint : View from P 1,285 Expansion Valve Air Outlet Air Side Heat-Exchanger Magnetic Switch Box Check Valve 2,150 P Water Cooler Screw Compressor Earth Terminal (M10) 30 (1,840) 30 NOTES: 1.Provide a 20 mesh water strainer at the chilled water inlet. The 20 mesh strainer is available by Hitachi as an optional accessory. 2.Specifications in this drawing are subject to change without notice, in order that Hitachi may bring the latest innovations to our customers. Mounting Holes (6-26) 100 1, Rigging Holes (4-50) (1,800) 100 3,800
9 Printed in Japan (H) HR-E551V Oct. 2015
MOLLIER DIAGRAM CAN BE IMPROVED!
MOLLIER DIAGRAM CAN BE IMPROVED! IMPROVED BASIC COOLING CIRCUIT PERFORMANCE EFFICIENCY USING AN ECONOMISER Eng. Jonny Malachi, VP Operations, Mashav Refrigeration and Air Conditioning Engineering Ltd.
More informationYour Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant
Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,
More informationGP SERIES Packaged Chillers
Blending Conveying Drying Process Cooling Heat Transfer Size Reduction GP SERIES Packaged Chillers Comprehensive Flexible Versatile Compact unitary designs available in a variety of configurations from
More informationVRF. Technical Data Book. DVM S Eco 8, 9 HP
VRF Technical Data Book DVM S Eco 8, 9 HP Version Modification Date Remark Ver.1.0 Released DVM S Eco 8,9HP TDB.06.26 Ver.1.1 Max pipe length modified(equivalent length) : 0 -> 130m 15.04.07 Nomenclature
More information1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS C35 PRODUCT SPECIFICATIONS Upflow - Cased and Uncased Bulletin No. 20666 February 208 Supersedes November 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION Unit Type C = Indoor Coil = Upflow Series
More information35 Copper Spun Driers Kap Kit Two Way Heat Pump Driers Suitable for HFC, CFC and HCFC.
Copper Spun Driers Suitable for HFC, CFC and HCFC. C440 MSCD-5-3 3/16 x 2.5mm C441 MSCD-15-3 3/16 x 2.5 C442 MSCD-15-4 1/4 x 2.5 C443 MSCD-20 1/4 x 2.5 C444 MSCD-30 1/4 x 2.5 C448 MSCD-20S 1/4 x 1/4 Kap
More informationAiredale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England
> For the latest information on our products please visit : www.airedale.com > Please refer to the technical manuals for more detailed information Your nearest Airedale distributor is: ISO 14001 EMS52086
More informationProduct Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres
Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how
More informationCOMMERCIAL AIR CONDITIONERS Flooded Type Water Cooled Screw Chiller 2012
MCAC-2012-37 COMMERCIAL AIR CONDITIONERS 2012 Commercial Air Conditioner Business Units Midea Air Conditioning and Refrigeration Sector Add: West region of Midea commercial air conditioner department,
More informationSINGLE. Technical Data Book. 4Way Cassette S for (Inv, R410A,
SINGLE Technical Data Book 4Way Cassette S for (Inv, R410A, 1 Ver.1.0 Release Single 4Way Cassette S for USA (Inv, R410A, 60Hz, HP) TDB 15.02.05 - Ver.1. 5.0.09 Ver.1..0.0 Ver.1..0. Index 1 Nomenclature
More informationSINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU
SINGLE Technical Data Book Big Duct for EU (R4A, 0Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU History Version Modification Date Remark Ver 1.0 Release SINGLE Big Duct for EU (R4A, 0Hz, HP)
More informationBlue e+ chillers with the principle
Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide
More informationENCLOSURE HEAT DISSIPATION
ENCLOSURE HEAT DISSIPATION DATA CENTER SOLUTIONS A White Paper by Great Lakes Case & Cabinet Company www.werackyourworld.com 814.734.7303 Page 2 Introduction Dangerous heat levels inside an enclosure threaten
More informationMission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire
Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices
More informationSlim duct (AMTTTFNLDEH ) Indoor units
Slim duct (AMTTTFNLDEH ) Slim duct. Specifications 1) Technical specifications Model AM22FNLDEH AM28FNLDEH AMFNLDEH AM4FNLDEH AMFNLDEH Power Supply Ø, #, V, Hz 1,2,22-24, 1,2,22-24, 1,2,22-24, 1,2,22-24,
More informationHoshizaki America, Inc.
Hoshizaki America, Inc. Low-Profile Modular Crescent Cuber Models KML-351MAH KML-351MWH A Superior Degree of Reliability PARTS LIST www.hoshizaki.com Number: 71267 Issued: 5-9-2008 Revised: 10-13-2014
More informationIT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw
IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE
More informationFPS SERIES Super Slim Ceiling Mount Air Handling Units
About Multistack 19, Multistack is well-known in the international air conditioning industry by its invention of modular chiller. Today, Multistack has grown into an international refrigeration & air conditioning
More informationglide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA
99 glide air cooled liquid chillers ND free cooling chillers glider 178 1328 Energy Class More efficient + B C D E F G Less efficient R134a CLSS SHELL C E C FREE COOLING 100 air cooled liquid chiller and
More informationMin. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,
ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) SXT+ Product Specifications HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208
More informationHIGH EFFICIENCY Central Chiller
Blending Conveying Drying Process Cooling Heat Transfer Size Reduction HIGH EFFICIENCY Central Chiller Energy Efficient Modular & Expandable Virtually Eliminate Downtime Available in 20-60 ton single units,
More informationHow To Draw Chiller Monsters Werewolves Vampires And Zombies
How To Draw Chiller Monsters Werewolves Vampires And Zombies We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer,
More informationHIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity
ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) Product Specifications HIGH EFFICIENCY 15 and 17 TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208 / 230 Volt,
More informationWerner Finley Private Limited
+91-8048719225 Werner Finley Private Limited https://www.indiamart.com/wernerfinley/ We are manufacturer & exporter of precious range of industrial cooling systems & industrial chillers that includes coolant
More informationHigh Voltage Induction Motors. 21-MII Series. New High Efficiency Design for High Capacity Applications Up to 3,550 kw (4,750 HP)
High Voltage Induction Motors -MII Series New High Efficiency Design for High Capacity Applications Up to,0 kw (,0 HP) MII Series: Combining over 00 years of experience with innovative new technology makes
More information3300 kw, Tier 3, Chilled Water, 70,000 ft 2
[Reference Design 22] 3300 kw, Tier 3, Chilled Water, 70,000 ft 2 DESIGN OVERVIEW Data Center IT Capacity 1100 kw per Data Hall 3 Independent Data Halls Design Application Range This design can be applied
More informationInfluence of Relevant Fluid Parameters on Pressure Pulsation of a Variable Lubricant Vane Pump
Influence of Relevant Fluid Parameters on Pressure Pulsation of a Variable Lubricant Vane Pump Thomas Fischer, development/calculation Jan Fischer, development/testing Nico Jäkel, development/construction
More informationLCP Hybrid Efficient performance with heat pipe technology
LCP Hybrid Efficient performance with heat pipe technology 2 LCP Hybrid The whole is more than the sum of its parts The same is true of "Rittal The System." With this in mind, we have bundled our innovative
More informationAtlas Copco. Dryers BD 480. Parts list. From following serial No. onwards: APF
Atlas Copco Dryers BD 480 Parts list From following serial No. onwards: APF 56 875 Copyright 0, Atlas Copco Airpower n.v., Antwerp, Belgium. Any unauthorized use or copying of the contents or any part
More informationGRASSO SYSTEM CONTROL
Control device for Packages and Chillers with screw compressors Product information 09.2002/ 2 638630_pi gsc gbr.doc Copyright GmbH Refrigeration Technology The contents of this documentation and the enclosed
More informationAIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS
PAH 2802 T K AIR R-407C R-134a Series PAH... T K from 205 to 778 kw - 2 circuits The air cooled heat pumps of PAH.T series are designed for outdoor installation and are particularly suitable for industrial
More informationCHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw
IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING
More informationEfficiency of Data Center cooling
Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and
More informationEcotel Free Cool 5-15kW
Precision Air Conditioning Free-cooling Ecotel Free Cool 5-15kW + + Self-contained compact outdoor cabin cooler + + 100% free-cooling + + -48V DC supply option + + Easy serviceability (front component
More informationAir-Cooled Series R Chiller
Air-Cooled Series R Chiller The next generation of Air-Cooled Helical Rotary Chillers ANOTHER RELIABLE SOURCE OF CHILLED WATER FROM TRANE The new industry standard f The next generation of the air-cooled
More informationChiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw
Chiller CG 010 to 130 Remote Air Cooled Condensers Engineering Data Manual 9.4 to 131 kw Specifications Unit identification CG. O. O55. FSC. R407C LN Configuration Refrigerant rpm fans Size Air flow Remote
More informationRelay Output Sequence for Heatcraft Chillers
Micro Control Systems APPLICATION NOTE APP-001 Relay Output Sequence for Heatcraft Chillers Revision History Date Author Description 12/10/96 Brian Walterick Created Application Note. 12/11/96 Brian Walterick
More informationU-Match Series DC Inverter Service Manual PRODUCT
PRODUCT 1 PRODUCT 1 MODELS LIST 1.1 Outdoor Unit Name Product Code Power Supply (V, Ph, Hz) Appearance GUHD24NS3GO CF090W0800 220-240V~ 50/60Hz GUHD36NS3GO CF090W0860 220-240V~ 50/60Hz GUHD42NS3GO CF090W0870
More informationChiller Replacement and System Strategy. Colin Berry Account Manager
Chiller Replacement and System Strategy Colin Berry Account Manager Current Situation 4 Existing RTAA chillers All units 23 years old Limited service history One unit MUST be replaced immediately One unit
More informationMotivair MLC-SC Air-Cooled Scroll Chillers Tons
INNOVATE DESIGN APPLY www.motivaircorp.com Motivair MLC-SC Air-Cooled Scroll Chillers 100 285 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Businesses who function in today s advanced
More informationFrigoPack FU+ New Generation of Intelligent Refrigeration Inverters
FU+ New Generation of Intelligent Refrigeration Inverters Efficient and Energy-saving Control of Refrigeration Compressors and Condenser Fans www.frigokimo.com Effective speed control saves energy and
More informationshop online:
Process systems Liquid ring vacuum pumps Single stage pumps 8 Alpha series single stage liquid ring vacuum pumps 9 AL series single stage liquid ring vacuum pumps 97 Two stage pumps 00 SHR series liquid
More informationLiquid Cooling Package LCP Cooling Systems
Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure,
More informationWiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number
30GXN,R Sizes 080-528 Air-Cooled Chillers with ComfortLink Controls 50/60 Hz Wiring Diagrams DIAGRAM INDEX POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number Label Diagram No. 30GX 080-178* ALL 1 505429
More informationLarge Tonnage Chillers. Kingsley Hu Technical Support Engineer
Large Tonnage Chillers Kingsley Hu Technical Support Engineer Chongqing Plant Chiller Products Reference Projects Manufacturing Facility Major Milestones Global R&D Talent Production Line introduction
More informationHVAC System Energy Savings Opportunities
HVAC System Energy Savings Opportunities Speaker Info M. Lant DuBose Energy Services ConEdison Solutions dubosem@conedsolutions.com (813)285-6340 Wholly owned subsidiary of ConEdison since 2007 Entered
More informationApplication Manual. Shark. Software for the simulation of refrigeration equipment and air conditioners
Page 1 of 184 Software for the simulation of refrigeration equipment and air conditioners Index Software for the simulation of refrigeration equipment and air conditioners... 1 : application description
More informationCooling Solutions & Considerations for High Performance Computers
Cooling Solutions & Considerations for High Performance Computers White Paper 6 Revision 1 By Rich Whitmore Executive summary The recent advances in high performance computing have driven innovations not
More informationSlim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL
E5-3I D-AP 4SP2U Slim Ducted type D-AP0074SP2U D-AP0094SP2U D-AP024SP2U D-AP054SP2U D-AP084SP2U Contents. Specifications 2. Dimensions 3. Center of gravity 4. Piping diagram 5. Wiring diagram 6. Electrical
More informationMPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers
INNOVATE DESIGN APPLY www.motivaircorp.com MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers ½ - 100 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Motivair is a world-class
More informationDIP. Spare parts list. Centrifugal pumps 25, 25-US, 35, 35-US, 65, 65-US Atlas Copco Construction Tools AB No c
DIP 5, 5US, 35, 35US, 65, 65US Spare parts list Centrifugal pumps 0 Atlas Copco Construction Tools AB No. 9800 5 0c 003 DIP 5, 5US, 35, 35US, 65, 65US Contents Contents General information................................................................
More information1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS CX35 Upflow - Cased - R-40A PRODUCT SPECIFICATIONS Bulletin No. 0668 November 06 Supersedes September 05.5 to 5 Tons MODEL NUMBER IDENTIFICATION C X 35-36 A - 6 F Unit Type C = Indoor Coil
More informationSystem Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks
Liquid Cooling for Data Centers System Overview The Chilldyne Cool-Flo System is a direct-to-chip liquid cooling system that delivers coolant under negative pressure. Chilldyne s technologies were designed
More informationOil Free Scroll. Air Compressors
Oil Free Scroll Air Compressors History of HITACHI Air Technology 1910 1930 1950 1970 1980 1911: 75kW Reciprocating First Compressor in Japan 1977: Smallest 5.5kW Oil Injected Rotary Screw 1976: Oil Injected
More informationMCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH
MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationWiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q
AQUASNAP 30RB060-390 Air-Cooled Liquid Chillers with COMFORTLINK Controls 60 Hz Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q INDEX* POWER SCHEMATICS 30RB Unit Size Voltage Figure Number Label
More informationMCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH
MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:
More informationA Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System
A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough
More informationEnergy Management of the Refrigeration Systems at Zurich Airport. Burkhard Bein. Schaffhausen,
Energy Management of the Refrigeration Systems at Zurich Airport Burkhard Bein Schaffhausen, 29.06.18 Overview Content: General Information Refrigeration concept EMS program CS program Three projects for
More informationMCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH
MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationFEATURES APPLICATIONS OPERATING DATA MATERIALS OF CONSTRUCTION. Flood control
APPLICATIONS FEATURES Flood control Irrigation Land drainage Pollution control Industry Water refineries Water parks Design OPERATING DATA Capacity:...up to.000 m/h Head:...up to m Max. water temperature:...0
More informationHow Green can you go?
ASHRAE 90.1 2010 It s out..and should be our code in 3 years Work on sealing and testing building envelope, commissioning Cool Roofs..hey were already doing that Extensive Controls enhancements Equipment
More information2018 Product overview
2018 Product overview Project conditioning Evolution goes on During these years, the activity of EMICON has been developed with the production of liquid chillers for conditioning and industrial applications,
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARYG72LHTA ARYG90LHTA OUTDOOR AOYG72LRLA AOYG90LRLA DR_AR012EF_03 2017.04.07 Notices: Product specifications and design are subject to change
More informationUPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps
VARIAN vacuum technologies UPGRADE PROGRAM V70 Series Pumps vs V81T Series Pumps Technical Memo Technical Memo - 1 - V70 series vs V81-T INDEX Outline drawings ISO63 3 Outline drawings CF2-¾ 4 Outline
More informationInstallation Manual. 1.Included Accessories. System Controller SC-201-6M INT. Requests to Installers *SHA8754 C*
System Controller SC-201-6M INT Installation Manual Potential dangers from accidents during installation and use are divided into the following two categories. Closely observe these warnings, they are
More information200 kw, Tier 3, Chilled Water, 5250 ft 2
[eference Design 4] 200 kw, Tier 3, Chilled Water, 5250 ft 2 DESIGN OVEVIEW Data Center IT Capacity 200 kw Adaptable from 50 kw to 600 kw Target Availability Tier 3 Annualized UE at 100% Load 1.67 in Miami,
More informationAIR COOLED CONDENSERS
AIR COOLED CONDENSERS NQAC Quiet Line HNSQAC NQAC Quiet Line kw () Highly efficient external rotor fan motors give optimum performance with low noise levels Multiple fans (on all except smallest models)
More informationAssembly and Maintenance
Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines
More informationSupplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers
Engineering Data SED: 8012 Group: Centrifugal Chiller Date: March 2002 Supercedes: New Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers Model WSC/WDC 2002 McQuay International
More informationIT Air Conditioning Units
IT Air Conditioning Units Modern Flexible Effective Energy Saving CoolTeg Plus and CoolTop overview CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC CoolTop Installation Between IT racks On top of IT rack
More informationNew Design Strategies for Energy Saving. Intelligent free-cooling
New Design Strategies for Energy Saving Intelligent free-cooling Intelligent New strategies for energy saving When designing mission critical systems for processing applications or highly technological
More informationSpare part catalogue GB 03/2007. Wall-hung boilers ecotec exclusive 832, 838 VUW 326/4-7 VUW 386/4-7
Spare part catalogue 0020037555.03 GB 03/2007 Wall-hung boilers ecotec exclusive 832, 838 VUW 326/4-7 VUW 386/4-7 Content General view of sheet Page 3 04 Burner Page 4 06 Heat exchanger Page 6 07 Casing
More informationAPPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance
APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS Capacity from 600 to 2,010kWr Engineered for flexibility and performance PRODUCT LEAFLET THE AWS SERIES OFFERS TOP EFFICIENCY, LOW SOUND LEVELS AND FLEXIBLE
More informationHIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.
HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM. SYSTEM LOGICA is the most advanced alternative to the problem of cooling of server rooms MONTAIR is the trademark which represents excellence on the market
More informationCeiling Concealed Split System C Series
Brochure AP MCC C 07A Ceiling Concealed Split System C Series features: Microprocessor Controlled ith the microprocessor controlling the operation, the MCC model can offer comfortable room conditions according
More informationROC T15 Technical specification
Atlas Copco Surface drill rigs ROC T15 Technical specification When small holes are big business is the smallest hydraulic drill rig in our range. It is perfect for small construction jobs, self-drilling
More informationAuraCool Economizer System
Page 1 Due to manufacturer's policy of continuous product improvement, the manufacturer reserves the right to make changes without notice. Drawings in this submittal are representations of the equipment
More informationSpecification and Design Catalog. Waterside Economizer
Specification and Design Catalog Waterside Economizer Table of Contents Waterside Economizer Applications.................................................... 4 Application Notes..................................................................
More informationThermal management. Thermal management
Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately
More informationHYFRA Sigma. Efficient, reliable cooling water recooling systems. Customized. Cooling. Solutions.
Sigma Efficient, reliable cooling water recooling systems Customized. Cooling. Solutions. 1 Sigma series Sigma series Cooling water recooling Sigma Trouble-free. Flexible. Efficient. The proven Sigma series
More informationOne Stop Cooling Solution. Ben Tam Business Development Manager
One Stop Cooling Solution Ben Tam Business Development Manager Agenda One Stop Cooling Solution Challenges Customers Are Facing Today Rack / Row / Room Solution Keynotes New Product Launch Slide 2 2 One
More informationLiebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability
Liebert AFC from 500 to 1700 kw The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC from 500 to 1700 kw Vertiv Vertiv designs, builds and services mission critical technologies that
More informationPrecision Cooling Mission Critical Air Handling Units
M I S S I O N C R I T I CA L C O O L I N G Precision Cooling Mission Critical Air Handling Units Global Expertise for Precision Cooling Solutions STULZ is a privately owned, global manufacturer of highly
More informationMoving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet
Moving Containment Inside the Enclosure Presented by Jeff Markle Great Lakes Case & Cabinet Containment Containment : To put constraint upon; to restrain; to confine; to keep within bounds Containment
More information4. TARGETED COOLING & AIRFLOW MANAGEMENT
4.4. TARGETED COOLING & TARGETED COOLING & AIRFLOW MANAGEMENT 4.AIRFLOW TARGETED MANAGEMENTCO 76 79 80 81 82 :: targeted cooling & airflow management 4. TARGETED COOLING & AIRFLOW MANAGEMENT 4.1 - Side
More informationCTC Low Temperature Process Chillers
INNOVATE DESIGN APPLY CTC Low Temperature Process Chillers 5-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough When it comes to process cooling, every application is unique in
More informationSPARE PARTS LIST CP COMPRESSOR. Model CPD CPD 75
SPARE PARTS LIST CP COMPRESSOR Model CPD 75-00 EN 05 0 5 CPD 75 CONTENTS Title Page MAINTENANCE HOW TO READ THIS SPARE PART LIST? MAINTENANCE KITS STANDARD UNITS MOTOR-COMPRESSOR UNIT -7 AIR CIRCUIT -9
More informationDNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書
DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書 Read and save these insturctions 2008 Antari Lighting & Effects Ltd. User Manual Antari DNG-200 Low fog Generator Congratulations on the purchase
More informationAPC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011
APC InRow Cooler Prototype Initial Report - Test Setup Verification H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011 1 Introduction Contents Technology Description/Attributes Installation
More informationDatasheet.
Industrial Test & Mixing Equipment Bringing Test Innovation to you Datasheet This product datasheet has been provided by John Godrich & SJ Electronics in Partnership with BINDER www.johngodrich.co.uk www.sjelectronics.co.uk
More informationAIR Compressor. Efficient Cooling System. PCG Series 01/02
AIR Compressor V-belt Connection Level energy efficiency motor Efficient motor specialized for compressors with long service life Rational configuration of compressors within the same range satisfies the
More informationDATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency
DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency September 27 th, 2013 Tejas Desai, PE CEM CEA LEED AP Sameer Behere, PE CEM LEED AP Agenda Problem: Quick fixes can
More informationPEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers
TM PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers WE ARE VERTIV Vertiv, formerly Emerson Network Power, designs, builds, and services mission critical technologies that
More informationAir Conditioning Technical Data FVA-A > FVA71AMVEB > FVA100AMVEB > FVA125AMVEB > FVA140AMVEB
Air Conditioning Technical Data FVA-A > FVA71AMVEB > FVA0AMVEB > FVA1AMVEB > FVA1AMVEB Indoor Unit FVA-A TABLE OF CONTENTS FVA-A 1 Features.............................................................
More informationXTREME ICE MAKER (1230 SERIES)
Anoka, MN. 0 Telephone -00--00 Facsimile -00--0 XTREME ICE MAKER (0 SERIES) MODEL NO. 00 00 00 00 00 00 0 Distributed By: Commercial Refrigeration Service, Inc. http://www.corneliusparts.com http://www.icecubes.net
More informationTotal Modular Data Centre Solutions
Sector Data Centre Total Modular Data Centre Solutions www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY CONTROLS SERVICE TRAINING 01 Standardised Modular Designs to fit your needs Our modular system
More information1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS PRODUCT SPECIFICATIONS Horizontal Bulletin No. 20667 November 206 Supersedes August 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION CH 35-8 A - 2 F Unit Type CH = Indoor - Horizontal Series Nominal
More informationCGAM air-cooled scroll chiller. Highly efficient, yet extremely quiet
CGAM air-cooled scroll chiller Highly efficient, yet extremely quiet Balancing energy efficiency and quiet operation Energy efficiency, sound, reliability, controls and service are all vitally important
More informationOptimizing Chilled Water Plant Performance. David Herman, PE, LEED AP Principal EnerG Associates, LLC
Optimizing Chilled Water Plant Performance David Herman, PE, LEED AP Principal EnerG Associates, LLC Optimizing Chilled Water Plant Learning Objectives Performance Review the design and operating characteristics
More information