Beckman Coulter System Reagent, AU400/AU400 e URINE CALCIUM ARSENAZO Cat. No.: OSR6x117 Reagent ID: 117
|
|
- Paul Alexander
- 5 years ago
- Views:
Transcription
1 Beckman Coulter System Reagent, AU400/AU400 e Test Name: CALA Type: Urine Operation: Yes Sample: Volume 2.0 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 25 L Dilution 225 L Min OD Max OD R2 Volume 0 L Dilution 0 L L H Reagent OD limit: Wavelength: Pri. 660 Sec. 700 First L -0.1 First H 2.0 Method: END Last L -0.1 Last H 2.0 Reaction slope: + Dynamic Range: Measuring Point 1: First 0 Last 10 L 0.1* H 40.0* Measuring First Last Correlation Factor: Linearity: % A 1 B 0 No Lag Time: On-board stability period: 90 Test Name: CALA Type: Urine Value/Flag: # Level L: # Level H: # Normal Ranges: Age L Age H Sex Year Month Year Month L H 1. # # # # # # # 2. # # # # # # # 3. # # # # # # # 4. # # # # # # # 5. # # # # # # # 6. # # # # # # # 7. None Selected # # 8. Out of Range L H # # Panic Value: # # Unit: mg/dl Decimal places: # Test Name: CALA Type Urine Calibration Type: AB Formula: Y=AX+B Counts: # Process: CONC Cal. No. OD CONC Factor/OD-L Factor/OD-H Point 1: # * Point 3: Point 4: Point 5: 1-Point Cal. Point: With CONC-0 Slope Check None Advanced Calibration: ## MB Type Factor: Calibration Stability Period: 30 # User defined ## Lot or Lot + Bottle Beckman Coulter System Calibrator Cat. No..: DR0090
2 Beckman Coulter System Reagent, AU640/AU640 e Test Name: CALA Type: Urine Operation: Yes Sample: Volume 2.0 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 25 L Dilution 225 L Min OD Max OD R2 Volume 0 L Dilution 0 L L H Reagent OD limit: Wavelength: Pri. 660 Sec. 700 First L -0.1 First H 2.0 Method: END Last L -0.1 Last H 2.0 Reaction slope: + Dynamic Range: Measuring Point 1: First 0 Last 10 L 0.1* H 40.0* Measuring First Last Correlation Factor: Linearity: % A 1 B 0 No Lag Time: On-board stability period: 90 Test Name: CALA Type: Urine Value/Flag: # Level L: # Level H: # Normal Ranges: Age L Age H Sex Year Month Year Month L H 1. # # # # # # # 2. # # # # # # # 3. # # # # # # # 4. # # # # # # # 5. # # # # # # # 6. # # # # # # # 7. None Selected # # 8. Out of Range L H # # Panic Value: # # Unit: mg/dl Decimal places: # Test Name: CALA Type Urine Calibration Type: AB Formula: Y=AX+B Counts: # Process: CONC Cal. No. OD CONC Factor/OD-L Factor/OD-H Point 1: # * Point 3: Point 4: Point 5: 1-Point Cal. Point: With CONC-0 Slope Check None Advanced Calibration: ## MB Type Factor: Calibration Stability Period: 30 # User defined ## Lot or Lot + Bottle
3 , AU480 Beckman Coulter System Reagent: OSR6x117 Test Name: CALA Type: Urine Operation: Yes Sample Volume 2.0 L Dilution 0 L OD Limit Pre-Dilution Rate 1 Min. OD Max. OD Reagents Volume: R1(R1-1) 25 L Dilution 225 L Reagent OD limit: R2 (R2-1) 0 L Dilution 0 L First Low -0.1 High 2.0 Last Low -0.1 High 2.0 Dynamic Range Low 0.1* High 40.0* Common Reagent Type None Name Correlation Factor A 1 B 0 Wavelength: Pri. 660 nm Sec. 700 nm Factor for Maker A 1 B 0 Method: END Reaction slope: + Onboard Stability 90 Day 0 Hour Measuring Point 1: First 0 Last 10 Measuring First Last Linearity: % No Lag Time: Range Test Name: CALA Type: Urine Value/Flag: VALUE Level L: # Level H: # Specific Ranges: From To Panic Value Sex Year Month Year Month Low High Low High 1. # # # # # # # # # 2. # # # # # # # 3. # # # # # # # 4. # # # # # # # 5. # # # # # # # 6. # # # # # # # 7. No demographics # # 8. Not within expected values # # Unit mg/dl* Decimal Places # Test Name: CALA Type Urine Use Serum Cal. Calibration Type: AB Formula: Y=AX+B Counts: # <Calibrator Parameters> Slope Check None Calibrator OD Conc Factor Range Low High Allowable Range Check Point 1: # * Reagent Blank Calibration Point 3: Advanced Calibration Point 4: Operation Yes Point 5: Interval (RB/ACAL) Lot / Lot Point 8: Point 9: Point10: <Point Cal. For Master Curve> No. of Correction Points Use Master Curve Lot Calibration Calibrator OD Conc OD Range Stability Low High Reagent Blanks 30 Day 0 Hour Point 1: Calibration 30 Day 0 Hour MB Type Factor: 1-Point Calibration Point With CONC-0 # User defined
4 , AU680 Beckman Coulter System Reagent: OSR6x117 Test Name: CALA Type: Urine Operation: Yes Sample Volume 2.0 L Dilution 0 L OD Limit Pre-Dilution Rate 1 Min. OD Max. OD Reagents Volume: R1(R1-1) 25 L Dilution 225 L Reagent OD limit: R2 (R2-1) 0 L Dilution 0 L First Low -0.1 High 2.0 Last Low -0.1 High 2.0 Dynamic Range Low 0.1* High 40.0* Common Reagent Type None Name Correlation Factor A 1 B 0 Wavelength: Pri. 660 nm Sec. 700 nm Factor for Maker A 1 B 0 Method: END Reaction slope: + Onboard Stability 90 Days 0 Hour Measuring Point 1: First 0 Last 10 Measuring First Last Linearity: % No Lag Time: Range Test Name: CALA Type: Urine Value/Flag: VALUE Level L: # Level H: # Specific Ranges: From To Panic Value Sex Year Month Year Month Low High Low High 1. # # # # # # # # # 2. # # # # # # # 3. # # # # # # # 4. # # # # # # # 5. # # # # # # # 6. # # # # # # # 7. No demographics # # 8. Not within expected values # # Unit mg/dl* Decimal Places # Test Name: CALA Type Urine Use Serum Cal. Calibration Type: AB Formula: Y=AX+B Counts: # <Calibrator Parameters> Slope Check None Calibrator OD Conc Factor Range Low High Allowable Range Check Point 1: # * Reagent Blank Calibration Point 3: Advanced Calibration Point 4: Operation Yes Point 5: Interval (RB/ACAL) Lot / Lot Point 8: Point 9: Point10: <Point Cal. For Master Curve> No. of Correction Points Use Master Curve Lot Calibration Calibrator OD Conc OD Range Stability Low High Reagent Blanks 30 Day 0 Hour Point 1: Calibration 30 Day 0 Hour MB Type Factor: 1-Point Calibration Point With CONC-0 # User defined * Values set for working in mg/dl. To work in SI units (mmol/l) multiple by 0.25
5 Beckman Coulter System Reagent, AU600 Specific test parameters Test No # Test name CALA Sample type Urine Page 1/2 Sample vol. 2 Dil. vol 0 l Min. OD Max. OD Reagent 1 vol 25 Dil. vol 225 l L H Reagent 2 vol 0 Dil. vol 0 l Reagent OD limit Fst. L -0.1 Fst. H 2.0 Wave Main 660 Sub 700 Lst. L -0.1 Lst. H 2.0 Method END Dynamic range Reaction + L 0.1* H 40.0* Point 1 Fst 0 Lst 10 Correlation factor A 1 Point 2 Fst Lst B 0 Linearity Fst % Sec % No lag time On-board stability period 90 Select using Space key, or select from list displayed by Guide key Test No # Test name CALA Sample type Urine Page 2/2 Level L Level H Value/flag # # # Normal range Sex Age L Age H L H 1 # # Y # M # Y # M # # 2 # # Y # M # Y # M # # 3 # # Y # M # Y # M # # 4 # # Y # M # Y # M # # 5 # # Y # M # Y # M # # 6 # # Y # M # Y # M # # 7 Non select # # 8 Out of range # # L H Panic value # # Select the function using the Function key or the Mouse Calibration specific Test No # Name CALA Cal type 8 AB Count # Formula 1 Y=AX+B Process CONC Selection calibrator Cal No OD Conc Factor/OD-L Factor/OD-H Point 1 # Point 2 Point 3 Point 4 Point 5 Point 6 Point 7 1-point cal. point MB type factor Calibrator stability period 30 Select the function using the Function key or the Mouse # To be inserted by the user
6 Beckman Coulter System Reagent, AU2700/AU5400 Test Name: CALA Type: Urine Operation: Yes Sample: Volume 2.0 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 25 L Dilution 225 L Min OD Max OD R2 Volume 0 L Dilution 0 L L H Reagent OD limit: Wavelength: Pri. 660 Sec. 700 First L -0.1 First H 2.0 Method: END Last L -0.1 Last H 2.0 Reaction slope: + Dynamic Range: Measuring Point 1: First 0 Last 10 L 0.1* H 40.0* Measuring First Last Correlation Factor: Linearity: % A 1 B 0 No Lag Time: On-board stability period: 90 Test Name: CALA Type: Urine Value/Flag: # Level L: # Level H: # Normal Ranges: Age L Age H Sex Year Month Year Month L H 1. # # # # # # # 2. # # # # # # # 3. # # # # # # # 4. # # # # # # # 5. # # # # # # # 6. # # # # # # # 7. None Selected # # 8. Out of Range L H # # Panic Value: # # Unit: mg/dl Decimal places: # Test Name: CALA Type Urine Calibration Type: AB Formula: Y=AX+B Counts: # Process: CONC Cal. No. OD CONC Factor/OD-L Factor/OD-H Point 1: # * Point 3: Point 4: Point 5: 1-Point Cal. Point: With CONC-0 Slope Check None Advanced Calibration: ## MB Type Factor: Calibration Stability Period: 30 # User defined ## Lot or Lot + Bottle
Beckman Coulter System Reagent, AU400/AU400 e URINE GLUCOSE Cat. No.: OSR6x21 Reagent ID: 021
Beckman Coulter System Reagent, AU400/AU400 e Test Name: GLU Type: Urine Operation: Yes Sample: Volume 3 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 50 L Dilution 150 L Min OD Max OD R2 Volume
More informationBeckman Coulter System Reagent, AU400/AU400 e URINE CREATININE Cat. No.: OSR6x78 Reagent ID: 078
Beckman Coulter System Reagent, AU400/AU400 e Test Name: CRE < > Type: Urine Operation: Yes Sample: Volume 8 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 120 μl Dilution 90 μl Min OD Max OD
More informationBeckman Coulter System Reagent, AU400/AU400e URINE AMYLASE Cat. No.: OSR6x06 Reagent ID: 006
Beckman Coulter System Reagent, AU400/AU400e Test Name: AMY Type: Urine Operation: Yes Sample: Volume 2 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 200 L Dilution 0 L Min OD Max OD R2 Volume
More informationBeckman Coulter System Reagent, AU400/AU400 e ETHYL ALCOHOL EMIT II PLUS Cat. No.: OSR9K229 Reagent ID: 524
Beckman Coulter System Reagent, AU400/AU400 e Test Name: ETOH+ < > Type: Urine Operation: Yes Sample: Volume 4 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 210 μl Dilution 0 μl Min OD Max
More informationBeckman Coulter System Reagent, AU400/AU400 e ALKALINE PHOSPHATASE (IFCC) Cat. No.: OSR6x04 Reagent ID: 004
Beckman Coulter System Reagent, AU400/AU400 e Test Name: ALP < > Type: Serum Operation: Yes Sample: Volume 3 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 60 μl Dilution 60 μl Min OD Max OD
More informationBeckman Coulter System Reagent, AU400/AU400 e AMPHETAMINES EMIT II PLUS, Semi-Quantitative (500 ng/ml Cutoff) Cat. No.: OSR9C229 Reagent ID: 520
Beckman Coulter System Reagent, AU400/AU400 e Sample: Volume 3 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 150 μl Dilution 0 μl Min OD Max OD R2 Volume 65 μl Dilution 10 μl L 0.00 H 2.50
More informationBeckman Coulter System Reagent, AU400/AU400 e LITHIUM Cat. No.: OSRT056 Reagent ID: 600
Beckman Coulter System Reagent, AU400/AU400 e Test Name: Li < > Type: Serum Operation: Yes Sample: Volume 2 μl Dilution 0 μl Pre-Dilution Rate: 10 Reagents: R1 Volume 150 μl Dilution 0 μl Min OD Max OD
More informationBICARBONATE (CO2), AU400/AU400 e System reagent: OSR6x37 Reagent ID: 037
BICARBONATE (CO2), AU400/AU400 e Test Name: CO2 < > Type: Serum Operation: Yes Sample: Volume 3 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 50 μl Dilution 210 μl Min OD Max OD R2 Volume 0
More informationBeckman Coulter System Reagent, AU400/AU400 e THYROXINE (T4) Cat. No.: Microgenics Cat. No Reagent ID: #
Beckman Coulter System Reagent, AU400/AU400 e Cat. No.: Microgenics Cat. No. 0454 Test Name: T4 < > Type: Serum Operation: Yes Sample: Volume 4 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume
More informationBeckman Coulter System Reagent, AU400/AU400 e ACETAMINOPHEN EMIT tox TM Cat. No.: OSR7A229 Reagent ID: 517
Beckman Coulter System Reagent, AU400/AU400 e Test Name: ACETA Type: Serum Operation: Yes Sample: Volume 3 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 150 L Dilution 0 L Min OD Max OD R2 Volume
More informationBeckman Coulter System Reagent, AU400/AU400 e METHOTREXATE EMIT Cat. No.: SYVA 6L119 Reagent ID:
Beckman Coulter System Reagent, AU400/AU400 e METHOTREXATE EMIT Cat. No.: SYVA 6L119 Sample: Volume 3 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 162 μl Dilution 0 μl Min OD Max OD R2 Volume
More informationDRI ph-detect APPLICATION BECKMAN COULTER AU640, AU680
Microgenics Corporation Part of Thermo Fisher Scientific DRI ph-detect APPLICATION BECKMAN COULTER AU640, AU680 Catalog No. 100054 Intended for the determination of urine ph. For In Vitro Diagnostic Use
More informationDRI CREATININE-DETECT APPLICATION BECKMAN COULTER AU640, AU680
Microgenics Corporation Part of Thermo Fisher Scientific DRI CREATININE-DETECT APPLICATION BECKMAN COULTER AU640, AU680 Catalog No. 1797 Intended for the quantitative determination of creatinine in human
More informationDRI ETHYL ALCOHOL ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800
DRI ETHYL ALCOHOL ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800 Catalog No. 0037, 0038 Intended for the quantitative determination of alcohol in human urine, serum
More informationDRI METHADONE METABOLITE ASSAY APPLICATION BECKMAN COULTER AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800
Microgenics Corporation Part of Thermo Fisher Scientific DRI METHADONE METABOLITE ASSAY APPLICATION BECKMAN COULTER AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800 Catalog Nos. 100115 and 100116 Intended
More informationDRI OXYCODONE APPLICATION BECKMAN COULTER AU480, AU680, AU5800
Microgenics Corporation Part of Thermo Fisher Scientific DRI OXYCODONE APPLICATION BECKMAN COULTER AU480, AU680, AU5800 Catalog No. 100248, 100249, 10015632 The DRI Oxycodone Enzyme Immunoassay is intended
More informationCEDIA METHADONE APPLICATION Beckman Coulter AU480 & AU680
Microgenics Corporation Part of Thermo Fisher Scientific CEDIA METHADONE APPLICATION Beckman Coulter AU480 & AU680 Catalog No. 100088, 100097, 1730916 Intended for the Qualitative and Semiquantitative
More informationCEDIA BARBITURATES APPLICATION Beckman Coulter AU480, AU680
CEDIA BARBITURATES APPLICATION Beckman Coulter AU480, AU680 Catalog No. 100084, 100093, 1661213, 10017365 Microgenics Corporation Part of Thermo Fisher Scientific Intended for the Qualitative and Semiquantitative
More informationQMS AMIKACIN ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800
Microgenics Corporation Part of Thermo Fisher Scientific QMS AMIKACIN ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800 Catalog No. 0373910 & 10017196 Intended for the
More informationThe NGAL Test Application Note for Abbott Architect c8000
The NGAL Test Application Note for Abbott Architect c8 General parameters Name: NGAL Assay number: *1 Assay version: 1 Assay type: Photometric Assay availability: Enabled Cal version: 1 Reaction definition
More informationThe NGAL Test Application Note for Roche Modular P
The NGAL Test Application Note for Roche Modular P NGAL Code (ACN) xxx ANALYZE Ser/Pl type Assay/Time/Point 2-Point-End 1 18 34 Wave (2nd/Primary) 8 57 Volume Reagent Vol. Diluent BCN OBS Timing Normal
More informationE21 Alarm List E Photometric Data Error (A) 3117 Lamp Off Error 3118 Lamp Dark Error 3120 Sample Probe (FA) Error (Up-Down) (A, B)[A, B, C, D
E21 Alarm List E21-1 Alarm List Alarm List 3010 Text Not Received (ANL
More information4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system
Specifications & more > > System Specifications > > Consumables > > Accessories System Overview Cat. No. 16300 Analyzer type 4 plate fully automated ELISA analyzer Reagent system Open (Human tests predefined)
More informationBCA protein assay kit for low concentrations. For measuring total protein concentration of pure proteins, extracts or lysates.
ab207002 BCA protein assay kit for low concentrations Instructions for use: For measuring total protein concentration of pure proteins, extracts or lysates. This product is for research use only and is
More informationLab ID 406. Your Parameters. Institution: Analyte. WBC Siemens Advia 120 Siemens 10 9 /L. RBC Siemens Advia 120 Siemens /L
Your Parameters Institution: Analyzer Reagent Cat N Reagent Manufacturer Method Group Calibrator Cat n Calibrator Cal Lot # Unit WBC Siemens Advia 12 Siemens 1 9 /L RBC Siemens Advia 12 Siemens 1 12 /L
More informationNovaspec Pro User Manual
Novaspec Pro User Manual Novaspec Pro 80-2120-50 5061-067 Rev 1.0 Table of Contents Essential Safety Notes...4 Unpacking, Positioning, Installation...4 Warranty and Repair...5 Technical Specifications.6
More informationPhone:
Innovation Biotech Co., Ltd Phone:86-10-68867437 Email:info@invbio.com www.invbio.com INV-100 PHOTOMETER USER S MANUAL This Manual contains reserved information. All rights reserved. Unauthorized copying
More informationQAM-I-102 Operation and Calibration of the Autoanalyzer
1. Applicability and Purpose a. This procedure applies to the operation and calibration of the LaChat Quikchem 8000 Automated Ion Analyzer. An equivalent system may be used with proper revision of this
More informationFACA-1240 Auto Chemistry Analyzer User s Manual
FACA-1240 Auto Chemistry Analyzer User s Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.VER.01-4.12 I How
More informationHOST COMPUTER INTERFACE SPECIFICATIONS
249099-L April 2001 TM HOST COMPUTER INTERFACE SPECIFICATIONS This manual is intended for use with SYNCHRON CX 4/CX 7 DELTA SYNCHRON CX4CE/CX7 SYNCHRON CX7 RTS/CX9 ALX SYNCHRON CX 4 PRO/CX 5 PRO/CX 7 PRO/CX
More information1 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (Max.) 1 plate /run Barcode reader
Specifications & more Elisys Uno > > System Specifications > > Consumables > > Accessories System Overview Cat.. 17350 Analyzer type 1 plate fully automated ELISA analyzer Reagent system Open (Human tests
More informationUV-6 Series Double Beam UV/Vis Spectrophotometers
UV-6 Series Double Beam UV/Vis Spectrophotometers Model UV-6100 UV-6100PC UV-6300 UV-6300PC avelength Range 190-1100nm 190-1100nm Spectral Bandwidth 1.8nm 1.8nm 1.0nm 1.0nm Optical System avelength Accuracy
More informationFULLY AUTOMATED 2 MICROPLATE ANALYZER
FULLY AUTOMATED 2 MICROPLATE ANALYZER The new Personal Lab,(Plab) is an integration between our unique extensive expertise and information gathered from thousands of installations. The new Plab is innovative
More informationBA-88A Semi-auto Chemistry Analyzer
BA-88A Semi-auto Chemistry Analyzer Main Contents Features Working principles Improvements from BA-88 Competitors Operation Price FAQ Features Test mode: flowcell or cuvette 7.0 TFT touch screen & popup
More informationProtein Quantification Kit (BCA Assay)
Protein Quantification Kit (BCA Assay) Booklet Item NO. KTD3001 Product Name Protein Quantification Kit (BCA Assay) ATTENTION For laboratory research use only. Not for clinical or diagnostic use Version
More informationNanoPhotometer TM USER MANUAL Version 2.0
NanoPhotometer TM USER MANUAL Version 2.0 Implen GmbH Schatzbogen 52 D-81829 Germany Declaration of conformity for the NanoPhotometer This is to certify that the Implen NanoPhotometer conforms to the requirements
More informationBIOWAVE DNA USER MANUAL
BIOWAVE DNA USER MANUAL Biochrom Ltd Tel: +44 (0)1223 423723 22 Cambridge Science Park Fax: +44 (0)1223 420164 Cambridge support@biochrom.co.uk CB4 0FJ England www.biochrom.co.uk Declaration of Conformity
More informationCHLORINE DIOXIDE (0 to 5.00 mg/l) Method 10126
CHLORINE DIOXIDE (0 to 5.00 mg/l) Method 10126 DPD Method* Scope and Application: for measuring chlorine dioxide in clean water For water 530 nm 1. Enter the stored program for chlorine dioxide (ClO 2
More informationWIZ Panel SOFTWARE OPERATING MANUAL. Verified: TM X
WIZ Panel SOFTWARE OPERATING MANUAL Manual Version Software version Prepared: Sysmedia Verified: TM Checked: QM Approved: MD Issued: 1.0 9.0X SOFWARE DESIGNED AND DEVELOPED BY: SYSMEDIA Srl Via Anoia,
More informationCOBAS INTEGRA 400 plus
COBAS INTEGRA 400 plus COBAS INTEGRA 400 plus is designed to consolidate testing and increase efficiency while reducing total running costs of the laboratory. The COBAS INTEGRA systems extensive assay
More informationab BCA protein assay kit reducing agent compatible (test tube)
ab207004 BCA protein assay kit reducing agent compatible (test tube) Instructions for use: For measuring total protein concentration of pure proteins, extracts or lysates in the presence of reducing agents.
More informationCH142 Spring Spectrophotometers with Vernier Data Acquisition Software
Spectrophotometers with Vernier Data Acquisition Software The absorbance of a sample is given as A = log I o I, where I o is the intensity without sample present and I is the intensity with the sample
More informationMicroplate Readers INSTRUMENTS. Description Catalog # Description DAR800 SF2100 SF4700
Microplate Readers DAR800 As a stand-alone Microplate reader, the DAR800 is designed for applications within the clinical, biotechnology and research areas. The onboard data reduction surpasses many computer
More informationSemi-auto Chemistry Analyzer User s Manual SACA-19900
Semi-auto Chemistry Analyzer User s Manual SACA-19900 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.010.14 How
More information6 peaks, 10 7 /ml. Figure 40 Histograms of the Ultra Rainbow
Spherotech, Inc. 30 27845 Irma Lee Circle, Lake Forest, IL 60045 SPHERO TM Ultra Rainbow Calibration Particle Kits Consists of one bead with multiple fluorophores and intensities for calibration Ultra
More informationElectrophoresis File Run Summary
2100 expert DE72901460_2010-02-02_14-04-56.xad Page 1 of 10 C:\...-02\2100 expert DE72901460_2010-02-02_14-04-56.xad Electrophoresis File Run Summary Instrument Information: Instrument Name: DE72901460
More informationEasyElectrolytes. With EasyElectrolytes, Medica has redefined electrolyte analyzer design
EasyElectrolytes With EasyElectrolytes, Medica has redefined electrolyte analyzer design Simple yes/no prompted operation, combined with a modular design makes EasyElectrolytes reliable and economical.
More informationUse of OBX-11/OBR-25 in IHE LAB3 context. IHE-PaLM 13 Nov Filip Migom
Use of OBX-11/OBR-25 in IHE LAB3 context. IHE-PaLM 13 Nov. 2017 Filip Migom Order Results Management [LAB-3] Shall we apply S or O? 20/12/2017 2016 CliniSys Group Commercial in Confidence 2 OBX-11 : Observation
More information315 ph/ion. Installation. Specifications. Installing the Batteries a595. Input Connectors
315 /Ion Installation Input Connectors socket (automatic temperature compensation) socket data socket reference socket If you ordered an electrode with the 315, connect it as follows: Corning Incorporated
More informationTech Note. Estimating Relative Potency for CVB using Gen5 Software. Background
Tech Note Estimating Relative Potency for CVB using Gen5 Software Background The USDA Center for Veterinary Biologics (CVB) has withdrawn SAM 318 (RelPot software) per CVB Notice 13-18. A more recent technical
More informationTL6 Ultra Micro-volume Spectrophotometer
TL6 Ultra Micro-volume Spectrophotometer TL6 is the latest Ultra Micro-volume Spectrophotometer of PERSEE ANALYTICS. It is a small portable instrument for fast analysis of nucleic acid and protein concentrations
More informationµl Spectrophotometer USER MANUAL
µl Spectrophotometer USER MANUAL PO Box 188 Saffron Walden CB10 9BA United Kingdom Tel: +44 (0) 131 2080522 info@picodrop.com www.picodrop.com All product and brand names used in the document are trademarks
More informationMicroplate Systems. Absorbance Microplate Readers 366. Performance Validation and Software Tools 368. Microplate Washer 370
/microplate/ Absorbance Microplate Readers 366 Performance Validation and Software Tools 368 Microplate Washer 370 Singleplex Assays and Reagents 371 Microplate Systems Absorbance Microplate Readers /microplate/
More informationWELCOME TO A member of
WELCOME TO A member of 1 BST Introduction Unit Consumables Berlin Unit Instruments Issum 2 BST Instruments - Laboratory Labtrend Consumables 3 BST POCT Instruments GLUKOMETER PRO LAC PRO 4 BST POCT Connectivity
More information1 Purpose. 2 New features. Release Notes tiamo 2.4
Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com Release Notes tiamo 2.4 1 Purpose This document describes the differences between the
More informationProvide Accurate Results. Operational Manual. Visible Spectrophotometer. SP-880 Mate. PC Software. Metertech Inc. Version 1.2.3
Provide Accurate Results Operational Manual Visible Spectrophotometer SP-880 Mate PC Software Metertech Inc. Version 1.2.3 Metertech Inc. provides this publication as is without warranty of any kind, either
More informationUsing I9131 Sodium Combination ISE on 3200I/M
Overview Using I9131 Sodium Combination ISE on 3200I/M This document demonstrates how to use I9131 Sodium Combination ISE on 3200I or 3200 M to measure pna or the concentration of [Na + ]. Applied to 3200I
More informationMINISCAN INSTRUCTIONS
MINISCAN INSTRUCTIONS DR VIRGINIA GORDON Version 3, July 2011 General Hints on Running Mini-Scan Tests... 1 Total Glycerin Test (TG)... 3 GENERAL HINTS ON RUNNING MINI-SCAN TESTS PIPETTES To use the pipettes
More informationUser s Manual. TBS-380 Mini-Fluorometer. Operating Manual. Dated: 08/14/2007 Rev. E
User s Manual TBS-380 Mini-Fluorometer Operating Manual Dated: 08/14/2007 Rev. E 645 N. Mary Avenue Sunnyvale, CA 94085 Phone: (408) 636-2400 Toll Free: (888) 636.2401 Fax: (408) 737-7919 www.turnerbiosystems.com
More informationSpherotech, Inc Irma Lee Circle, Lake Forest, IL
New flow cytometers, with fluorescent channels from the UV to Far Red, and corresponding fluorescent conjugates are now available. As a result, we have developed the Ultra Rainbow Fluorescent Particles
More informationLIGHT SOURCE Quartz-iodine lamp 12V-20W.
SPECIFICATIONS THROUGHPUT Up to 180 tests per hour; Up to 300 tests per hour with ISE unit. REAGENT SYSTEM Rotor with 24 positions for 25 ml bottles and 8 positions for 5 ml bottles. All positions can
More informationReference Guide for the Value Assignment Web v
Reference Guide for the Value Assignment Web v 1.02.01 Bio-Rad Laboratories 9500 Jeronimo Road Irvine, CA 92618 Copyright 2008 Contents Introduction to the Value Assignment Web 1 Benefits of the Value
More informationAMERICAN ASSOCIATION OF BIOANALYSTS 205 West Levee St. Brownsville, TX (281) (800) Fax (713)
Amylase - Initial Grouping by Method Beckman AMY 1 213.5-396.6 P 305.07 10.1 92.6-172.1 P 132.36 7.9 14 Siemens Dimension 2 129.4-240.2 P 184.79 3.4 51.0-94.6 P 72.80 4.3 20 Extremely low recovery meth
More informationUV / VIS SPECTROPHOTOMETER
www.mapada.com.cn A Professional Manufacturer Shanghai Mapada Instruments Co., Ltd. Add: Building D-10, 261# Sanbang Rd., Songjiang Export Processing Zone,Shanghai, 201611 Tel: +86-21-5488 1172 +86-21-5488-0273
More informationDimension EXL 200 Integrated Chemistry System Technical Specifications
Dimension EXL 200 Integrated Chemistry System Technical Specifications Overview The Dimension EXL 200 Integrated Chemistry System offers revolutionary chemiluminescent technology and automated, productivity-enhancing
More informationSartorius Biohit Picus Electronic Pipettes
Sartorius Biohit Picus Electronic Pipettes Enjoy pipetting Achieve better results Learn to use it in a minute Description Picus electronic pipette is intended to be used in liquid handling applications
More informationSE-330 SERIES (NEW REVISION) MODBUS/TCP INTERFACE
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/se-330 SE-330 SERIES (NEW REVISION) MODBUS/TCP INTERFACE Revision 0-E-121117 Copyright 2018 Littelfuse Startco Ltd. All rights reserved.
More informationUsing Graphical Analysis This exercise will familiarize you with using Graphical Analysis in Beer s Law and kinetics.
Using Graphical Analysis 3.1.1 This exercise will familiarize you with using Graphical Analysis in Beer s Law and kinetics. Beer s Law In this exercise you will plot a calibration curve of absorbance versus
More informationOperating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University
Operating Manual High Performance Liquid Chromatograph Agilent 1100 ; VWD, DAD, FLD and RID Scientific Equipment Center, Prince Of Songkla University Operating Manual High Performance Liquid Chromatograph
More informationCreating a data file and entering data
4 Creating a data file and entering data There are a number of stages in the process of setting up a data file and analysing the data. The flow chart shown on the next page outlines the main steps that
More informationExcel Primer CH141 Fall, 2017
Excel Primer CH141 Fall, 2017 To Start Excel : Click on the Excel icon found in the lower menu dock. Once Excel Workbook Gallery opens double click on Excel Workbook. A blank workbook page should appear
More informationPrecision Measuring Instrument P650-EX/P655-EX
DOSTMANN electronic DOSTMANN electronic DOSTMANN electronic Precision Measuring Instrument P650-EX/P655-EX Dostmann electronic GmbH Zum Ottersberg 12 D-97877 Wertheim-Reicholzheim Tel: ++49 (0)9342 / 30890
More informationWorking with Data sent to a Computer or Flash Stick
Working with Data sent to a Computer or Flash Stick File Names and File Formats Data sent to a flash stick is saved as a.txt file. The file name for the saved file is in the format: DATA FILE TYPE Send
More informationArc Module SU ph. Modbus RTU Programmer s Manual. Firmware version: EPHUM070. Arc Module SU ph Modbus RTU Programmer s Manual (EPHUM070)
Arc Module SU ph RTU Programmer s Manual Firmware version: EPHUM070 627143/00 page 1 / 56 Important Notice All rights reserved. No part of this document may be reproduced, stored in a retrieval system,
More informationUser Manual (Vers. 1.03)
PLUSSoftUsb Power Meter Mode User Manual (Vers. 1.03) Laserpoint srl - Via Burona, 51-20090 Vimodrone (Milano) - Italy Phone +39 02 27 400 236 - Telefax +39 02 25 029 161 www.laserpoint.it 1 Contents CONTENTS
More informationElectrolyte analyzer i-smart 30
Electrolyte analyzer i-smart 30 Overview i-sens electrolyte analyzer, i-smart 30 uses 60 μl of blood sample to measure ions such as Na+, K+, Cl- and hematocrit automatically. Unlike other competitors products,
More informationSection 4.3: How Derivatives Affect the Shape of the Graph
Section 4.3: How Derivatives Affect the Shape of the Graph What does the first derivative of a function tell you about the function? Where on the graph below is f x > 0? Where on the graph below is f x
More informationDCA Vantage A n a l y z e r. Operator's Guide. REF Rev. E,
DCA Vantage A n a l y z e r Operator's Guide REF 06489264 Rev. E, 2012-08 2012 Siemens Healthcare Diagnostics. All rights reserved. No part of this manual or the products it describes may be reproduced
More informationHow to correct and complete discharge data Main text
Table of Contents. General 2. Completion from another record at the same station 3. Interpolating discharge gaps of short duration 4. Interpolating gaps during recessions 5. Interpolation using regression
More informationSelect the group of isolates you want to analyze using the chart and statistics tool Create a comparison of these isolates Perform a query or
Using the Chart & Statistics Tool and Groups Steven Stroika April 2011 Overview Using the Chart and Statistics Tool Utility of Graphs in Cluster Detection and Reporting Utility of Groups Chart and Statistics
More informationM3.1 Translate information between graphical, numerical and algebraic forms =
Maths tutorial booklet for M3: Graphs Name: Target grade: Quiz scores: M3.1 Translate information between graphical, numerical and algebraic forms = M3.2 Plot two variables from experimental or other data
More informationCoSMoS Starter Guide 1.4 Hoskins Lab Last Modified 03/03/2017 Chris DeCiantis
Contents Start Up:... 2 Turn on Shutter controllers... 2 Turn on Lasers... 2 Turn on other equipment:... 2 Load Slide onto Sample Holder:... 2 Turn on Computer/ Start Labview/Glimpse:... 3 Shutters Activate.vi
More informationRIDA GENE real-time PCR DNA Assays
R-Biopharm AG RIDA GENE real-time PCR DNA Assays Set-up for ABI7500/FAST (Software Version.0) R-Biopharm for reliable diagnostics. Step : To set up a template for DNA Assays After opening the ABI7500 software,
More informationSupramolecular Approach to Enzyme Sensing on Paper Discs Using Lanthanide Photoluminescence
Supporting Information for Supramolecular Approach to Enzyme Sensing on Paper Discs Using Lanthanide Photoluminescence Tumpa Gorai and Uday Maitra* Department of Organic Chemistry, Indian Institute of
More informationP/ACE MDQ Basic Training Workbook
TM P/ACE MDQ Basic Training Workbook For 32 Karat Software Version 5.0 715091 AA August 2001 Beckman Coulter, Inc. 4300 N. Harbor Blvd., Fullerton, CA 92835 Copyright 2001 Beckman Coulter, Inc. PrintedinU.S.A.
More informationHygroLog HL20 and HL21 Data Logger. User Guide
Page 1 of 17 HygroLog HL20 and HL21 Data Logger Page 2 of 17 Table of contents: 1. Overview... 3 1.1 General... 3 2. General description... 4 2.1 Models... 4 2.2 Required accessories... 4 2.3 Batteries...
More informationData Sheet. Item Specification Comment
1 (14) Dokumentnamn/Document name Data Sheet Dokumentnummer/Document number Physical Specifications Doc.no. 544753 Ver. 2.0 1(15) Instrument Width: 680 mm Depth: 600 mm Height: 440 mm Packed instrument
More informationNANO SPECTROPHOTOMETER
PRODUCT CATALOG NANO SPECTROPHOTOMETER www.biolabscientific.com NANO SPECTROPHOTOMETER Biolab Nano spectrophotometer is a compact, micro volume UV Visible Spectrophotometer with enhanced sensitivity that
More informationSE-330 SERIES (NEW REVISION) ETHERNET/IP INTERFACE
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/se-330 SE-330 SERIES (NEW REVISION) ETHERNET/IP INTERFACE Revision 3-E-121117 Copyright 2018 Littelfuse Startco All rights reserved.
More informationCoSMoS Starter Guide 1.6 Hoskins Lab Last Modified 03/30/2017 Chris DeCiantis
Contents Start Up:... 2 Turn on Shutter controllers... 2 Turn on Lasers... 2 Turn on other equipment:... 2 Load Slide onto Sample Holder:... 2 Turn on Computer/ Start Labview/Glimpse:... 3 Shutters Activate.vi
More informationAppendix 1: DataStudio with ScienceWorkshop Sensors Tech Tips
Appendix 1: DataStudio with ScienceWorkshop Sensors Tech Tips Section 1: Starting an experiment 1.1 Opening a file 1. Open the File menu and select Open Activity. 2. In the Open dialog box, navigate to
More informationModel FP-6500 Spectrofluorometer Instruction Manual. FP-6500 for Windows
Model FP-6500 Spectrofluorometer Instruction Manual FP-6500 for Windows P/N: 0302-9999 April 2000 Contents Safety Considerations...i Regulatory Statements... iii Preface... iv Installation Conditions...v
More informationscil Technical Support
Vet ABC Hematology Analyzer Calibration ** Before Calibration is performed run a concentrated cleaning and make sure your Photometer is within range. After both are completed run a Startup by pressing
More informationModbus Register sc200 ph ORP Module
Powered by TCPDF (www.tcpdf.org) Modbus Register sc200 ph ORP Module V2.02 SENSOR 40001 Unsigned 1 R 0 /65535 Measurement tag selection ORP 40002 Float 2 R -2100 /2100 ORP measurement ph 40004 Float 2
More informationDiving into a new dimension: Quality meets efficiency
Diving into a new dimension: Quality meets efficiency DR 6000 UV-VIS spectrophotometer Combining quality and cost-effectiveness The new DR 6000 UV-VIS spectrophotometer delivers top performance for both
More informationSpectroscopic Ellipsometer --- J. A. Woollam alpha-se
Spectroscopic Ellipsometer --- J. A. Woollam alpha-se Introduction Figure 1: J. A. Woollam alpha-se spectroscopic ellipsometer An ellipsometer measures the change in polarization as light reflects or transmits
More information111 Highland Drive Putnam, CT USA PHONE (860) FAX (860) SM32Pro SDK
SM32Pro SDK Spectrometer Operating Software USER MANUAL SM301/SM301EX Table Of Contents Warranty And Liability...3 Quick Start Installation Guide...4 System Requirements...5 Getting Started...6 Using the
More informationDOSTMANN electronic. Precision Measuring Instrument P600-EX/P605-EX/P650-EX/P655-EX. Operation manual
DOSTMANN electronic DOSTMANN electronic DOSTMANN electronic Precision Measuring Instrument P600-EX/P605-EX/P650-EX/P655-EX Dostmann electronic GmbH Waldenbergweg 3b D-97877 Wertheim-Reicholzheim Tel: ++49
More informationCyberComm Pro Data Acquisition Software Installation & User Guide
CyberComm Pro 2.2.3 Data Acquisition Software Installation & User Guide ph 1100 and ph 2100 Bench ph and Bench ph/ion Meter Technology Made Easy... 68X090822 rev 1 Aug 2002 2 PREFACE Thank you for selecting
More informationCatalog Number DOC DR 2800 USER MANUAL. September 2005, Edition 1. Hach Company, All rights reserved. Printed in the U.S.A.
Catalog Number DOC022.53.00720 DR 2800 USER MANUAL September 2005, Edition 1 Hach Company, 2005. All rights reserved. Printed in the U.S.A. te/dk Visit us at www.hach.com Table of Contents Section 1 Specifications...5
More information