6 peaks, 10 7 /ml. Figure 40 Histograms of the Ultra Rainbow

Size: px
Start display at page:

Download "6 peaks, 10 7 /ml. Figure 40 Histograms of the Ultra Rainbow"

Transcription

1 Spherotech, Inc Irma Lee Circle, Lake Forest, IL SPHERO TM Ultra Rainbow Calibration Particle Kits Consists of one bead with multiple fluorophores and intensities for calibration Ultra Rainbow Calibration Kit, in all channels of the flow cytometer Designed for routine calibration and long term performance tracking Used to optimize the linearity, resolution and sensitivity Simplifies the calibration in the UV, Violet, Far Red, and IR channels. A new set of calibration particles, Ultra Rainbow Calibration Particles, are now available for performance tracking of flow cytometers with fluorescent channels in the Far Red. The Ultra Rainbow Calibration Particle Kits are available in either 3.8 µm, or 5.1 µm. These particles are supplied as a kit. One 3mL bottle of blank particles and a 2 ml bottle of fluorescent particles. The Ultra Rainbow Calibration Particles have improved resolution in the PE-Cy7, APC, and APC-Cy7 channels. Figure 39 Histograms of the Ultra Rainbow Calibration Particles (Cat. No. URCP-38-2K, Lot No. AG01) on a Stratedigm S1400. Particle Type and Surface Size, µm Catalog No. Unit Ultra Rainbow Calibration Kit, Ultra Rainbow Calibration Kit, Ultra Rainbow Calibration, 3 peaks, 10 6 /ml Ultra Rainbow Calibration, URCP-38-2K 2 ml URCP-38-20K 20 ml URCP-50-2K 2 ml URCP K 10x3mL URCP ml Figure 40 Histograms of the Ultra Rainbow Calibration Particles (Cat. No. URCP-38-2K, Lot No. AG01) on a Beckman Coulter Cyan TM ADP. FITC-LogH PE-LogH PE-TR-LogH APC-LogH PE-Cy5-LogH APC-Cy7-LogH PE-Cy7-LogH Cas Blue-LogH Visit us on the web at

2 Spherotech, Inc Irma Lee Circle, Lake Forest, IL Figure 41 Histograms showing individual peaks representing various fluorescence intensities in Rainbow Calibration Particles (Catalog No. URCP-38-2K, Lot No. AG01) on a BD Bioscience LSRFortessa TM X-20 are shown Figure 42 Histograms showing individual peaks representing various fluorescence intensities in Rainbow Calibration Particles (Catalog No. URCP-50-2K, Lot No. AG01) on a BD Bioscience LSRFortessa TM X-20 are shown Visit us on the web at

3 Spherotech, Inc Irma Lee Circle, Lake Forest, IL Figure 43 Histograms of the Ultra Rainbow Calibration Particles (Cat. No. URCP-38-2K, Lot No. AD03) on a BD FacsCanto TM II. * Data provided by Laura Marszalek, Northwestern Memorial Hospital. Visit us on the web at

4 Figure 44 Histograms of the Ultra Rainbow Calibration Particles (Cat. No. URCP-38-2K, Lot No. AD03) on a BD LSR TM II. Spherotech, Inc Irma Lee Circle, Lake Forest, IL * Data provided by Laura Marszalek, Northwestern Memorial Hospital. Visit us on the web at

5 Spherotech, Inc Irma Lee Circle, Lake Forest, IL Figure 45 Histograms of the Ultra Rainbow Calibration Particles (Cat. No. URCP-38-2K, Lot No. AG01) on a Millipore easycyte12. Side Sca SC-HLin) Plot P01, ungated R Forward C-HLin) Plot P04, gated on R1 Green-V Fl RN-V-HLog) Plot P07, gated on R1 Green-B Fl RN-B-HLog) Plot P02, gated on R Forward Sca (FSC-HLin) Plot P05, gated on R1 Yellow-V Flu (YEL-V-HLog) Plot P08, gated on R1 Yellow-B Flu (YEL-B-HLog) Plot P03, gated on R1 Blue-V Fluo BLU-V-HLog) Plot P06, gated on R1 Red-V Fluor RED-V-HLog) Plot P09, gated on R1 Red-B Fluor RED-B-HLog) Plot P10, gated on R1 Near IR-B F NI R-B-HLog) Plot P11, gated on R1 Red-R Fluor RED-R-HLog) Plot P12, gated on R1 Near IR-R F NI R-R-HLog) Visit us on the web at

6 Spherotech, Inc Irma Lee Circle, Lake Forest, IL Figure 46 Histograms of the Ultra Rainbow Calibration Particles (Cat. No. URCP-50-2K, Lot No. AG01) on a Beckman Coulter Cyan TM ADP. Visit us on the web at

Spherotech, Inc Irma Lee Circle, Lake Forest, IL

Spherotech, Inc Irma Lee Circle, Lake Forest, IL New flow cytometers, with fluorescent channels from the UV to Far Red, and corresponding fluorescent conjugates are now available. As a result, we have developed the Ultra Rainbow Fluorescent Particles

More information

Near UV Laser System Performance on the CytoFLEX S

Near UV Laser System Performance on the CytoFLEX S Near UV Laser System Performance on the CytoFLEX S APPLICATION NOTE Authors: Jeffrey Cobb James Tung Affiliation: Life Science, Beckman Coulter, Inc., Miami, FL, United States Introduction Material and

More information

Setup protocol for Firefly particles. On BD LSR II and LSRFortessa cytometers with single tube loader function

Setup protocol for Firefly particles. On BD LSR II and LSRFortessa cytometers with single tube loader function Setup protocol for Firefly particles On BD LSR II and LSRFortessa cytometers with single tube loader function Version 1 Last Updated May 2016 Setup protocol for Firefly particles Contents Introduction

More information

Setup protocol for Firefly particles. On BD FACSCanto cytometers with single tube loader function

Setup protocol for Firefly particles. On BD FACSCanto cytometers with single tube loader function Setup protocol for Firefly particles On BD FACSCanto cytometers with single tube loader function Version 1 Last Updated May 2016 Setup protocol for Firefly particles Contents Introduction Cytometer requirements

More information

APS (Automatic Population Separator)

APS (Automatic Population Separator) Infinicyt provides a list of very powerful tools for research and diagnosis of haematological diseases through flow cytometry data analysis. The features that most distinguish Infinicyt software from other

More information

Science is hard. Flow cytometry should be easy.

Science is hard. Flow cytometry should be easy. Science is hard. Flow cytometry should be easy. CFlow User Guide TABLE OF CONTENTS 1 INTRODUCTION TO CFLOW... 1 1.1 Installing CFlow... 1 1.2 Starting CFlow... 1 1.3 CFlow Workspace... 2 1.4 Opening a

More information

CyFlow ML. Healthcare Immunology Pathology Microbiology Cell Biology. Multilaser 16 Parameter Desktop FCM System

CyFlow ML. Healthcare Immunology Pathology Microbiology Cell Biology. Multilaser 16 Parameter Desktop FCM System CyFlow ML Healthcare Immunology Pathology Microbiology Cell Biology Multilaser 16 Parameter Desktop FCM System 01 COMPANY Flow Cytometry made in Germany New sophisticated applications and increasing requirements

More information

FX500 Exchangeable Fluidics Cell Sorter

FX500 Exchangeable Fluidics Cell Sorter FX5 Exchangeable Fluidics Cell Sorter Sony Biotechnology Inc. FX5 Cell Sorter Sorting Made Simple The FX5 is a microfluidics chip based cell sorter featuring a fully replaceable fluidics system. This lets

More information

Tutorial: FCAP Array Software with BD FACSArray Bioanalyzer

Tutorial: FCAP Array Software with BD FACSArray Bioanalyzer Tutorial: FCAP Array Software with BD FACSArray Bioanalyzer After completing this tutorial you will be able to: Create an Experiment with the Experiment Wizard in FCAP Array software. Export the Experiment

More information

Sysmex CyFlow Cube Series

Sysmex CyFlow Cube Series Sysmex CyFlow Cube Series Reliable, Compact and Cost-effective Flow Cytometers For Research Use Only. Not for use in diagnostic or therapeutic procedures. Sysmex CyFlow Cube Series Compact, Economic Flow

More information

Offline Flow Cytometry Analysis Software: Importance of Scaling and Data Visualization

Offline Flow Cytometry Analysis Software: Importance of Scaling and Data Visualization WHITEPAPER Offline Flow Cytometry Analysis Software: Importance of Scaling and Data Visualization Objectives Learn about the flow cytometry open platform data structure and how it facilitates for robust

More information

FACScan 4 and 5 Color Upgrade Rainbow Users Guide

FACScan 4 and 5 Color Upgrade Rainbow Users Guide FACScan 4 and 5 Color Upgrade Rainbow Users Guide For Research Use Only 1 Table of Contents Overview... 3 Hardware Specifications... 3 Rainbow Software... 4 Rainbow Preferences Window... 5 Setting up the

More information

USER GUIDE TO BECKMAN COULTER FC500

USER GUIDE TO BECKMAN COULTER FC500 USER GUIDE TO BECKMAN COULTER FC500 Create a New Protocol Purpose: This procedure describes how to define the parameters and create rough analysis plots for a new experimental set-up. Some protocol templates

More information

LSRFortessa Guide. Cell Evaluation and Therapy Core HO324

LSRFortessa Guide. Cell Evaluation and Therapy Core HO324 LSRFortessa Guide Cell Evaluation and Therapy Core HO324 Before Use: Prime the instrument twice with no tube and arm to the side Ensure that sheath is full and waste is empty To Begin: Log into ilabs tracker

More information

DIAplex. DIAplex Pro 1.0 Software. Instructions for use. Fast Track Your Research. For research use only

DIAplex. DIAplex Pro 1.0 Software. Instructions for use. Fast Track Your Research. For research use only DIAplex DIAplex Pro 1.0 Software Instructions for use For research use only Fast Track Your Research Table of Contents 1. Introduction... 2 2. DIAplex Pro 1.0 installation... 2 2.1. System Requirements...

More information

FACSAria Fusion SORP QUICK REFERENCE GUIDE

FACSAria Fusion SORP QUICK REFERENCE GUIDE FACSAria Fusion SORP QUICK REFERENCE GUIDE INSTRUMENT: 1. The computer is left on at all times. Note: If not Username: Admin Password: BDIS 2. Ensure the flow cell access door is open. You will want to

More information

A Bright Cytometer Easy to use

A Bright Cytometer Easy to use BriCyte E6 Flow Cytometer A Bright Cytometer Easy to use BriCyte E6 Flow Cytometer Flow cytometer is an essential tool to analyze cells, so it s used for diagnosis as well as research in laboratories worldwide.

More information

FACCalibur Users Guide

FACCalibur Users Guide FACCalibur Users Guide FACSCalibur Start Up Procedure If the Instrument is OFF: 1. Check the sheath and waste tanks. Open the fluidics drawer (front of instrument) and check the levels of sheath fluid

More information

FACSLSRFortessa SORP QUICK REFERENCE GUIDE

FACSLSRFortessa SORP QUICK REFERENCE GUIDE FACSLSRFortessa SORP QUICK REFERENCE GUIDE INSTRUMENT: 1. The computer is left on at all times. Note: If not Username: Administrator Password: BDIS 2. Unlock the screen with your PPMS account (UTSW username

More information

BD FACSDiva Software Quick Reference Guide for BD FACSCanto Systems with Loader Option

BD FACSDiva Software Quick Reference Guide for BD FACSCanto Systems with Loader Option BD FACSDiva Software Quick Reference Guide for BD FACSCanto Systems with Loader Option This guide contains instructions for using BD FACSDiva software version 6 with BD FACSCanto and BD FACSCanto II systems

More information

MA900 Multi-Application Cell Sorter

MA900 Multi-Application Cell Sorter MA9 Multi-Application Cell Sorter Sony Biotechnology Inc. MA9 Cell Sorter Sorting Made Simple The MA9 from Sony meets the needs of most sorting applications, supporting 12 fluorescence parameters and 4-way

More information

Technical Note. Display of BD Accuri C6 Software- Generated FCS 3.0 Files Using FlowJo for PC and Mac v7.6. Introduction

Technical Note. Display of BD Accuri C6 Software- Generated FCS 3.0 Files Using FlowJo for PC and Mac v7.6. Introduction Display of BD Accuri C6 Software- Generated FCS 3.0 Files Using FlowJo for PC and Mac v7.6 Contents 1 Introduction 2 Before You Begin 3 Using Global FlowJo Preferences 5 Usinig the Transform Button 5 Saving

More information

North America/International Japan Europe

North America/International Japan Europe North America/International Japan Europe 1730 North First Street San Jose, CA 95112 U.S.A. Voice: +1 800-275-5963 FAX: +1 408-352-4130 sales@sonybiotechnology.com http://www.sonybiotechnology.com 1-7-1,

More information

BD CellQuest Pro Acquisition Tutorial

BD CellQuest Pro Acquisition Tutorial BD CellQuest Pro Acquisition Tutorial Introduction This tutorial guides you through a CellQuest Pro Acquisition run like the one demonstrated in the CellQuest Pro Acquisition Movie on the BD FACStation

More information

BD Lyoplate Human Screen Analysis Instructions For analysis using FCS Express or FlowJo and heatmap representation in Excel 2007

BD Lyoplate Human Screen Analysis Instructions For analysis using FCS Express or FlowJo and heatmap representation in Excel 2007 BD Biosciences Technical Resources Page 1 For use with the BD Lyoplate Human Cell Surface Marker Screening Panel (Cat. No. 560747). Please check that your catalog numbers for the FCS Express Excel templates

More information

Flow Cytometry/FACS Bio-Rad S3e Cell Sorter

Flow Cytometry/FACS Bio-Rad S3e Cell Sorter Flow Cytometry/FACS Bio-Rad S3e Cell Sorter Contents Brief Description... 3 Reference... 3 Location... 3 Suggestion for Materials and Methods... 4 Suggestion for Acknowledgements... 4 People and Contacts...

More information

LEGENDplex Data Analysis Software Version 8 User Guide

LEGENDplex Data Analysis Software Version 8 User Guide LEGENDplex Data Analysis Software Version 8 User Guide Introduction Welcome to the user s guide for Version 8 of the LEGENDplex data analysis software for Windows based computers 1. This tutorial will

More information

Data acquisition and analysis of MACSPlex Exosome Kit using the MACSQuant Analyzer Express Mode in MACSQuantify Software version 2.

Data acquisition and analysis of MACSPlex Exosome Kit using the MACSQuant Analyzer Express Mode in MACSQuantify Software version 2. Data acquisition and analysis of MACSPlex Exosome Kit using the MACSQuant Analyzer Express Mode in MACSQuantify Software version 2.8 Contents 1. Description 1.1 Background information 1.2 Reagent and instrument

More information

Offline Flow Cytometry Analysis Software: Importance of Scaling and Data Visualization

Offline Flow Cytometry Analysis Software: Importance of Scaling and Data Visualization WHITEPAPER Offline Flow Cytometry Analysis Software: Importance of Scaling and Data Visualization Objectives Learn about the flow cytometry open platform data structure and how it facilitates for robust

More information

CyAn ADP Guide. Starting Up

CyAn ADP Guide. Starting Up CyAn ADP Guide Starting Up 1. Check the sheath and waste fluids, if needed, fill and empty: 1. To fill the Sheath Tank: a. Unscrew the top of the tank labeled Sheath Tank, and set it on top of the tank.

More information

flowqb Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity *

flowqb Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity * flowqb Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity * Josef Spidlen 1, Wayne Moore 2, Faysal El Khettabi, David Parks 2, Ryan Brinkman 1 1 Terry Fox Laboratory, British

More information

SH800S Cell Sorter. Sony Biotechnology Inc.

SH800S Cell Sorter. Sony Biotechnology Inc. SH8S Cell Sorter Sony Biotechnology Inc. SH8S Cell Sorter Sorting Made Simple The benchtop SH8S cell sorter permits sorting of a wide range of cell sizes and applications using the 7 µm, 1 µm, and 13 µm

More information

BD CellQuest Pro Software Acquisition Tutorial

BD CellQuest Pro Software Acquisition Tutorial BD CellQuest Pro Software Acquisition Tutorial This tutorial guides you through a typical acquisition using BD CellQuest Pro software. If you are already familiar with previous versions of BD CellQuest

More information

Log into the computer using your CU Denver username and password. Log into the DIVA software using your CU and Username and the password flow

Log into the computer using your CU Denver username and password. Log into the DIVA software using your CU and Username and the password flow Log into the computer using your CU Denver username and password Log into the DIVA software using your CU and Username and the password flow When DIVA opens, IF a CST Mismatch pop up box appears, then

More information

The Danish Stem Cell Center (DanStem) Danish Stem Cell Center Flow Cytometry Core Facility. LSR Fortessa Guide

The Danish Stem Cell Center (DanStem) Danish Stem Cell Center Flow Cytometry Core Facility. LSR Fortessa Guide Danish Stem Cell Center Flow Cytometry Core Facility LSR Fortessa Guide LSR Fortessa Overview The Danish Stem Cell Center (DanStem) BD FACSFlow Supply System Fluidics Cart Sheath container Waste container

More information

JMJ-Group Microbiology BMB SDU

JMJ-Group Microbiology BMB SDU JMJ-Group Microbiology BMB SDU Title: Daily use of FACS Aria II SOP number: SOPFACS0042_v01 Version number: 01 Date issued: 2013.01.16 Review date: 2014.12.01 Written by: Tina Kronborg and Michelle Madelung

More information

Data acquisition and analysis of MACSPlex Cytokine Kits using the MACSQuant Analyzer Express Modes in MACSQuantify Software version 2.

Data acquisition and analysis of MACSPlex Cytokine Kits using the MACSQuant Analyzer Express Modes in MACSQuantify Software version 2. Data acquisition and analysis of MACSPlex Cytokine Kits using the MACSQuant Analyzer Express Modes in MACSQuantify Software version 2.6 Contents 1. Description 1.1 Background information 1.2 Reagent and

More information

FACSLyric TM General User instructions

FACSLyric TM General User instructions flowkon Flow Cytometry User Instructions at the University of Konstanz FACSLyric TM General User instructions In BD FACSuite software, you can measure and analyze samples using either assays or experiments.

More information

DRI METHADONE METABOLITE ASSAY APPLICATION BECKMAN COULTER AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800

DRI METHADONE METABOLITE ASSAY APPLICATION BECKMAN COULTER AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800 Microgenics Corporation Part of Thermo Fisher Scientific DRI METHADONE METABOLITE ASSAY APPLICATION BECKMAN COULTER AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800 Catalog Nos. 100115 and 100116 Intended

More information

UNC Flow Cytometry Core Facility LSR II Operation 2018

UNC Flow Cytometry Core Facility LSR II Operation 2018 Reference: Startup BD FACSDiva 6 Online Course BD Training & elearning 1. Check Sheath and Waste containers: Empty Waste container in the sink Add bleach to the black mark ( ~10% final concentration).

More information

BD Multiwell AutoSampler Additional Features Tutorial

BD Multiwell AutoSampler Additional Features Tutorial BD Multiwell AutoSampler Additional Features Tutorial Introduction This tutorial provides step-by-step instructions on how to use the additional features available in BD Multiwell Plate Manager (MPM) software

More information

Beckman Coulter System Reagent, AU400/AU400 e URINE GLUCOSE Cat. No.: OSR6x21 Reagent ID: 021

Beckman Coulter System Reagent, AU400/AU400 e URINE GLUCOSE Cat. No.: OSR6x21 Reagent ID: 021 Beckman Coulter System Reagent, AU400/AU400 e Test Name: GLU Type: Urine Operation: Yes Sample: Volume 3 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 50 L Dilution 150 L Min OD Max OD R2 Volume

More information

Beckman Coulter System Reagent, AU400/AU400 e URINE CALCIUM ARSENAZO Cat. No.: OSR6x117 Reagent ID: 117

Beckman Coulter System Reagent, AU400/AU400 e URINE CALCIUM ARSENAZO Cat. No.: OSR6x117 Reagent ID: 117 Beckman Coulter System Reagent, AU400/AU400 e Test Name: CALA Type: Urine Operation: Yes Sample: Volume 2.0 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 25 L Dilution 225 L Min OD Max OD R2

More information

Comparing technical specification documents

Comparing technical specification documents Comparing technical specification documents Introduction Flow cytometer manufacturers provide technical specification sheets (tech specs or spec sheets) that describe the instruments key performance characteristics,

More information

Intelligent Biosafety: MoFlo Astrios fully integrated with the Biosafety Cabinet and Aerosol Evacuation System

Intelligent Biosafety: MoFlo Astrios fully integrated with the Biosafety Cabinet and Aerosol Evacuation System Intelligent Biosafety: MoFlo Astrios fully integrated with the Biosafety Cabinet and Aerosol Evacuation System Introduction As with any sorter that requires jet-in-air sorting, aerosols are created both

More information

MERGE FILES TUTORIAL. Version 1.4

MERGE FILES TUTORIAL. Version 1.4 MERGE FILES TUTORIAL Version 1.4 1. INTRODUCTION The merge process consists on adding two or more sample data files from the same sample or from different samples. The file resulting from the merging will

More information

Attune NxT Acoustic Focusing Cytometer

Attune NxT Acoustic Focusing Cytometer USER GUIDE Attune NxT Acoustic Focusing Cytometer Catalog Numbers A24858, A24859, A24860, A24861, A24862, A24863, A24864, A28993 Publication Number 100024235 Revision C.0 For Research Use Only. Not for

More information

Data acquisition and analysis of MACSPlex Cytokine Kits using the MACSQuant Analyzer Express Modes in MACSQuantify Software version 2.

Data acquisition and analysis of MACSPlex Cytokine Kits using the MACSQuant Analyzer Express Modes in MACSQuantify Software version 2. Data acquisition and analysis of MACSPlex Cytokine Kits using the MACSQuant Analyzer Express Modes in MACSQuantify Software version 2.8 Contents 1. Description 1.1 Background information 1.2 Reagent and

More information

Alternative Filters (all non-standard)

Alternative Filters (all non-standard) Fluorochrome Excitation (nm) Emission (nm) Best Filter (available) LP Alternative Filters (all non-standard) Notes 7-AAD 488;546 647 710/50;670/30 685;635 670/30 BP with 635LP* NOTE: very high spectral

More information

FloMax Software for Cytometry. Operating Manual Instrument Control and Acquisition. FloMax Operating Manual Instrument Control and Acquisition

FloMax Software for Cytometry. Operating Manual Instrument Control and Acquisition. FloMax Operating Manual Instrument Control and Acquisition FloMax Software for Cytometry Operating Manual Instrument Control and Acquisition 1 Contents Introduction to FloMax Software Acquisition and Instrument Control...3 Operating Basics - Preparing FloMax for

More information

STANDARD OPERATING PROCEDURE FOR THE LSR II

STANDARD OPERATING PROCEDURE FOR THE LSR II The Flow Cytometry Facility STANDARD OPERATING PROCEDURE FOR THE LSR II All users must follow the SOP & fill in the logbook. If you are unsure about anything please do not hesitate to ask for help. Before

More information

CELLQuest Acquisition Tutorial

CELLQuest Acquisition Tutorial CELLQuest Acquisition Tutorial Introduction This tutorial guides you through a CELLQuest Acquisition run like the one demonstrated in the CELLQuest Acquisition Movie on the FACStation Overview CD-ROM.

More information

Flow Cytometry & FACS Core Facility

Flow Cytometry & FACS Core Facility ZMBH - Zentrum für Molekulare Biologie der Universität Heidelberg Flow Cytometry & FACS Core Facility BD FACSCanto TM with HTS User's Guide For authorization to use the FACSCanto II cytometer, you first

More information

BD Cytometric Bead Array Software User s Guide

BD Cytometric Bead Array Software User s Guide BD Cytometric Bead Array Software User s Guide http://www.bdbiosciences.com/ Part No. 334409 Rev. B Version 1.4 April 2003 United States BD Biosciences Customer/Technical Service Tel 877.232.8995 Fax 408.954.2347

More information

User Manual. For Windows operating systems Excelsior Blvd. Suite Pécs St. Louis Park, MN Kedves street 20

User Manual. For Windows operating systems Excelsior Blvd. Suite Pécs St. Louis Park, MN Kedves street 20 User Manual For Windows operating systems Soft Flow, Inc. Soft Flow Hungary Ltd. 5009 Excelsior Blvd. Suite 154 7628 Pécs St. Louis Park, MN 55416 Kedves street 20 USA Hungary Tel: +1 (952) 681-7960 Tel:

More information

BD FACSDiVa Option. BD Biosciences Clontech Discovery Labware Immunocytometry Systems Pharmingen

BD FACSDiVa Option. BD Biosciences Clontech Discovery Labware Immunocytometry Systems Pharmingen BD FACSDiVa Option The Digital Advantage for the BD FACSVantage SE Flow Cytometry System BD Biosciences Clontech Discovery Labware Immunocytometry Systems Pharmingen Proven Performance in Flow Cytometry

More information

Canto II Operation Protocol

Canto II Operation Protocol Canto II Operation Protocol Make sure the following actions have been taken before running your samples. Make sure the waste tank is empty and refilled with 500 ml clean (see page 15 for details) Make

More information

Beckman Coulter System Reagent, AU400/AU400 e THYROXINE (T4) Cat. No.: Microgenics Cat. No Reagent ID: #

Beckman Coulter System Reagent, AU400/AU400 e THYROXINE (T4) Cat. No.: Microgenics Cat. No Reagent ID: # Beckman Coulter System Reagent, AU400/AU400 e Cat. No.: Microgenics Cat. No. 0454 Test Name: T4 < > Type: Serum Operation: Yes Sample: Volume 4 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume

More information

DRI ph-detect APPLICATION BECKMAN COULTER AU640, AU680

DRI ph-detect APPLICATION BECKMAN COULTER AU640, AU680 Microgenics Corporation Part of Thermo Fisher Scientific DRI ph-detect APPLICATION BECKMAN COULTER AU640, AU680 Catalog No. 100054 Intended for the determination of urine ph. For In Vitro Diagnostic Use

More information

CEDIA METHADONE APPLICATION Beckman Coulter AU480 & AU680

CEDIA METHADONE APPLICATION Beckman Coulter AU480 & AU680 Microgenics Corporation Part of Thermo Fisher Scientific CEDIA METHADONE APPLICATION Beckman Coulter AU480 & AU680 Catalog No. 100088, 100097, 1730916 Intended for the Qualitative and Semiquantitative

More information

flowworkspace: A Package for Importing flowjo Workspaces into R

flowworkspace: A Package for Importing flowjo Workspaces into R flowworkspace: A Package for Importing flowjo Workspaces into R Greg Finak February 24, 2014 1 Purpose The purpose of this package is to provide functionality to import relatively simple

More information

Beckman Coulter System Reagent, AU400/AU400 e METHOTREXATE EMIT Cat. No.: SYVA 6L119 Reagent ID:

Beckman Coulter System Reagent, AU400/AU400 e METHOTREXATE EMIT Cat. No.: SYVA 6L119 Reagent ID: Beckman Coulter System Reagent, AU400/AU400 e METHOTREXATE EMIT Cat. No.: SYVA 6L119 Sample: Volume 3 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 162 μl Dilution 0 μl Min OD Max OD R2 Volume

More information

igem2016 Microbiology BMB SDU

igem2016 Microbiology BMB SDU igem2016 Microbiology BMB SDU Project type: Plastic Project title: Characterizing and optimizing PHB production Sub project: 1. Comparison of PHB producing strains Creation date: 2016.08.24 Written by:

More information

Instructions for Use. COULTER EPICS XL Flow Cytometer COULTER EPICS XL-MCL Flow Cytometer SYSTEM II Software. PN CA (September 2010)

Instructions for Use. COULTER EPICS XL Flow Cytometer COULTER EPICS XL-MCL Flow Cytometer SYSTEM II Software. PN CA (September 2010) READY ON FS SS AUX FL1 FL2 FL3 FL4 TM COULTER EPICS XL Flow Cytometer COULTER EPICS XL-MCL Flow Cytometer SYSTEM II Software Instructions for Use CYTOMETER LASER SAMPLE FLOW LOW MED HIGH (September 2010)

More information

BD Biosciences (see pages 2-4) BD Diagnostics (see pages 5-7)

BD Biosciences (see pages 2-4) BD Diagnostics (see pages 5-7) GENERAL SERVICES ADMINISTRATION FEDERAL SUPPLY SERVICE Authorized Federal Supply Schedule List Effective: June 1, 2006 thru May 31, 2011 On-line access to contract ordering information, terms and conditions,

More information

Beckman Coulter System Reagent, AU400/AU400 e ACETAMINOPHEN EMIT tox TM Cat. No.: OSR7A229 Reagent ID: 517

Beckman Coulter System Reagent, AU400/AU400 e ACETAMINOPHEN EMIT tox TM Cat. No.: OSR7A229 Reagent ID: 517 Beckman Coulter System Reagent, AU400/AU400 e Test Name: ACETA Type: Serum Operation: Yes Sample: Volume 3 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 150 L Dilution 0 L Min OD Max OD R2 Volume

More information

Cytomics FC 500 Quick Reference

Cytomics FC 500 Quick Reference Cytomics FC 500 Quick Reference PN 722238 RevA (April 2005) Beckman Coulter Inc. Miami Education Center Miami Lakes, WARNINGS AND PRECAUTIONS READ ALL PRODUCT MANUALS AND CONSULT WITH BECKMAN COULTER-TRAINED

More information

CEDIA BARBITURATES APPLICATION Beckman Coulter AU480, AU680

CEDIA BARBITURATES APPLICATION Beckman Coulter AU480, AU680 CEDIA BARBITURATES APPLICATION Beckman Coulter AU480, AU680 Catalog No. 100084, 100093, 1661213, 10017365 Microgenics Corporation Part of Thermo Fisher Scientific Intended for the Qualitative and Semiquantitative

More information

Beckman Coulter System Reagent, AU400/AU400 e URINE CREATININE Cat. No.: OSR6x78 Reagent ID: 078

Beckman Coulter System Reagent, AU400/AU400 e URINE CREATININE Cat. No.: OSR6x78 Reagent ID: 078 Beckman Coulter System Reagent, AU400/AU400 e Test Name: CRE < > Type: Urine Operation: Yes Sample: Volume 8 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 120 μl Dilution 90 μl Min OD Max OD

More information

FlowJo Software Lecture Outline:

FlowJo Software Lecture Outline: FlowJo Software Lecture Outline: Workspace Basics: 3 major components 1) The Ribbons (toolbar) The availability of buttons here can be customized. *One of the best assets of FlowJo is the help feature*

More information

BICARBONATE (CO2), AU400/AU400 e System reagent: OSR6x37 Reagent ID: 037

BICARBONATE (CO2), AU400/AU400 e System reagent: OSR6x37 Reagent ID: 037 BICARBONATE (CO2), AU400/AU400 e Test Name: CO2 < > Type: Serum Operation: Yes Sample: Volume 3 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 50 μl Dilution 210 μl Min OD Max OD R2 Volume 0

More information

Overstock & Clearance Catalog

Overstock & Clearance Catalog 626 Hanover Pike, Suite 102 Hampstead, MD 21074 P: 410-374-3250 F: 410-374-3184 Overstock & Clearance Catalog Filters & Lenses & Rings (Oh My) Edition 2 Prices & Specifications are subject to change without

More information

Hacking FlowJo VX. 42 Time-Saving FlowJo Shortcuts To Help You Get Your Data Published No Matter What Flow Cytometer It Came From

Hacking FlowJo VX. 42 Time-Saving FlowJo Shortcuts To Help You Get Your Data Published No Matter What Flow Cytometer It Came From Hacking FlowJo VX 42 Time-Saving FlowJo Shortcuts To Help You Get Your Data Published No Matter What Flow Cytometer It Came From Contents 1. Change the default name of your files. 2. Edit your workspace

More information

CyFlow Cube 6 Instrument Operating Manual

CyFlow Cube 6 Instrument Operating Manual CyFlow Cube 6 Instrument Operating Manual CyFlow Cube 6 CyFlow Cube 8 - Instrument Operating Manual For in vitro diagnostic use with Partec recommended IVD reagents. IVD The PartecCyFlow Cube Flow Cytometer

More information

Gallios Flow Cytometer

Gallios Flow Cytometer Gallios Flow Cytometer For Research use only, not for use in diagnostic procedures. Quick Reference PN A75199AB.1 (May 2011) Beckman Coulter Inc. PN A75199AB.1 (May, 2011) 1 of 24 WARNINGS AND PRECAUTIONS

More information

Beckman Coulter System Reagent, AU400/AU400 e LITHIUM Cat. No.: OSRT056 Reagent ID: 600

Beckman Coulter System Reagent, AU400/AU400 e LITHIUM Cat. No.: OSRT056 Reagent ID: 600 Beckman Coulter System Reagent, AU400/AU400 e Test Name: Li < > Type: Serum Operation: Yes Sample: Volume 2 μl Dilution 0 μl Pre-Dilution Rate: 10 Reagents: R1 Volume 150 μl Dilution 0 μl Min OD Max OD

More information

DRI CREATININE-DETECT APPLICATION BECKMAN COULTER AU640, AU680

DRI CREATININE-DETECT APPLICATION BECKMAN COULTER AU640, AU680 Microgenics Corporation Part of Thermo Fisher Scientific DRI CREATININE-DETECT APPLICATION BECKMAN COULTER AU640, AU680 Catalog No. 1797 Intended for the quantitative determination of creatinine in human

More information

Quick Start Guide: COLLECT

Quick Start Guide: COLLECT Quick Start Guide: COLLECT Ready, Set, Run! The Collect tab is used to collect or import a sample, configure the run settings and set up plots and gates. Collect a Sample 1. Start the C6 Flow Cytometer,

More information

Kaluza C Analysis Software PROTECTS YOUR DATA AND YOUR REPUTATION.

Kaluza C Analysis Software PROTECTS YOUR DATA AND YOUR REPUTATION. Kaluza C Analysis Software PROTECTS YOUR DATA AND YOUR REPUTATION. KALUZA C ANALYSIS SOFTWARE Kaluza C Flow Cytometry Analysis Software is built upon our successful Kaluza Analysis research use platform.

More information

Release Notes Life Technologies Attune NxT Cytometric Software v 2.0.0

Release Notes Life Technologies Attune NxT Cytometric Software v 2.0.0 Release Notes Life Technologies Attune NxT Cytometric Software v 2.0.0 In the following pages you will find instructions describing: 1. Software installation 2. New software features and fixes 3. Known

More information

HIAC Liquid Particle Counting System. Easily configurable for maximum flexibility

HIAC Liquid Particle Counting System. Easily configurable for maximum flexibility HIAC 9703+ Liquid Particle Counting System Easily configurable for maximum flexibility Efficient Compliance Highly Flexible Advanced Diagnostics Time Saving, Faster and Easier Protects Your Investment

More information

6 th International Conference on Applied Informatics Eger, Hungary, January 27 31, MMA Technology. Robert Tornai

6 th International Conference on Applied Informatics Eger, Hungary, January 27 31, MMA Technology. Robert Tornai 6 th International Conference on Applied Informatics Eger, Hungary, January 27 31, 2004. MMA Technology Robert Tornai Department of Computer Graphics, University of Debrecen e-mail: rtornai@inf.unideb.hu

More information

Beckman Coulter System Reagent, AU400/AU400 e AMPHETAMINES EMIT II PLUS, Semi-Quantitative (500 ng/ml Cutoff) Cat. No.: OSR9C229 Reagent ID: 520

Beckman Coulter System Reagent, AU400/AU400 e AMPHETAMINES EMIT II PLUS, Semi-Quantitative (500 ng/ml Cutoff) Cat. No.: OSR9C229 Reagent ID: 520 Beckman Coulter System Reagent, AU400/AU400 e Sample: Volume 3 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 150 μl Dilution 0 μl Min OD Max OD R2 Volume 65 μl Dilution 10 μl L 0.00 H 2.50

More information

Gallios TM Quick Reference

Gallios TM Quick Reference Gallios TM Quick Reference Purpose: The purpose of this Quick Reference is to provide a simple step by step outline of the information needed to perform various tasks on the system. We begin with basic

More information

BD Accuri C6 with single tube loader protocol. For multiplex assays

BD Accuri C6 with single tube loader protocol. For multiplex assays BD Accuri C6 with single tube loader protocol For multiplex assays BD Accuri C6 with single tube loader protocol This protocol contains instructions for setting up an Accuri C6 with Tube Loader. If you

More information

HIAC Liquid Particle Counting System. Easily configurable for maximum flexibility

HIAC Liquid Particle Counting System. Easily configurable for maximum flexibility HIAC 9703+ Liquid Particle Counting System Easily configurable for maximum flexibility Efficient Compliance Highly Flexible Advanced Diagnostics Time Saving, Faster and Easier Protects Your Investment

More information

Standard Operating Procedure For: Independent End User Training and Maintaining Optimal Instrument Performance:

Standard Operating Procedure For: Independent End User Training and Maintaining Optimal Instrument Performance: Shared Resources: Flow Cytometry and Cell Sorting Standard Operating Procedure For: Independent End User Training and Maintaining Optimal Instrument Performance: DHVI BD LSRII (L01/L02) and BD LSRFortessa

More information

Beckman Coulter System Reagent, AU400/AU400e URINE AMYLASE Cat. No.: OSR6x06 Reagent ID: 006

Beckman Coulter System Reagent, AU400/AU400e URINE AMYLASE Cat. No.: OSR6x06 Reagent ID: 006 Beckman Coulter System Reagent, AU400/AU400e Test Name: AMY Type: Urine Operation: Yes Sample: Volume 2 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 200 L Dilution 0 L Min OD Max OD R2 Volume

More information

Summit Software WorkList Builder Quick Start Guide

Summit Software WorkList Builder Quick Start Guide Summit Software WorkList Builder Quick Start Guide Document Number 0003185 Revision July 2006 2 Summit WorkList Builder Quick Start Guide Disclaimer Summit Worklist Builder is a Research Use Only software

More information

Lab ID 406. Your Parameters. Institution: Analyte. WBC Siemens Advia 120 Siemens 10 9 /L. RBC Siemens Advia 120 Siemens /L

Lab ID 406. Your Parameters. Institution: Analyte. WBC Siemens Advia 120 Siemens 10 9 /L. RBC Siemens Advia 120 Siemens /L Your Parameters Institution: Analyzer Reagent Cat N Reagent Manufacturer Method Group Calibrator Cat n Calibrator Cal Lot # Unit WBC Siemens Advia 12 Siemens 1 9 /L RBC Siemens Advia 12 Siemens 1 12 /L

More information

Beckman Coulter System Reagent, AU400/AU400 e ETHYL ALCOHOL EMIT II PLUS Cat. No.: OSR9K229 Reagent ID: 524

Beckman Coulter System Reagent, AU400/AU400 e ETHYL ALCOHOL EMIT II PLUS Cat. No.: OSR9K229 Reagent ID: 524 Beckman Coulter System Reagent, AU400/AU400 e Test Name: ETOH+ < > Type: Urine Operation: Yes Sample: Volume 4 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 210 μl Dilution 0 μl Min OD Max

More information

Standard Operating Procedure For: Independent End User Training and Maintaining Optimal Instrument Performance:

Standard Operating Procedure For: Independent End User Training and Maintaining Optimal Instrument Performance: Shared Resources: Flow Cytometry and Cell Sorting Standard Operating Procedure For: Independent End User Training and Maintaining Optimal Instrument Performance: DHVI BD LSRII (L01/L02) and BD LSRFortessa

More information

DRI OXYCODONE APPLICATION BECKMAN COULTER AU480, AU680, AU5800

DRI OXYCODONE APPLICATION BECKMAN COULTER AU480, AU680, AU5800 Microgenics Corporation Part of Thermo Fisher Scientific DRI OXYCODONE APPLICATION BECKMAN COULTER AU480, AU680, AU5800 Catalog No. 100248, 100249, 10015632 The DRI Oxycodone Enzyme Immunoassay is intended

More information

Beckman Coulter System Reagent, AU400/AU400 e ALKALINE PHOSPHATASE (IFCC) Cat. No.: OSR6x04 Reagent ID: 004

Beckman Coulter System Reagent, AU400/AU400 e ALKALINE PHOSPHATASE (IFCC) Cat. No.: OSR6x04 Reagent ID: 004 Beckman Coulter System Reagent, AU400/AU400 e Test Name: ALP < > Type: Serum Operation: Yes Sample: Volume 3 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 60 μl Dilution 60 μl Min OD Max OD

More information

QMS AMIKACIN ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800

QMS AMIKACIN ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800 Microgenics Corporation Part of Thermo Fisher Scientific QMS AMIKACIN ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800 Catalog No. 0373910 & 10017196 Intended for the

More information

iscope fluorescence HIGHLIGHTS TECHNICAL SPECIFICATIONS EYEPIECE(S) HEADS NOSEPIECE OBJECTIVES STAGES

iscope fluorescence HIGHLIGHTS TECHNICAL SPECIFICATIONS EYEPIECE(S) HEADS NOSEPIECE OBJECTIVES STAGES iscope fluorescence HIGHLIGHTS HWF 10x/22 mm eyepieces Binocular and trinocular models Optional ergonomic tilting head Quintuple revolving nosepiece E-Plan, plan and plan fluarex corrected IOS objectives

More information

DRI ETHYL ALCOHOL ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800

DRI ETHYL ALCOHOL ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800 DRI ETHYL ALCOHOL ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800 Catalog No. 0037, 0038 Intended for the quantitative determination of alcohol in human urine, serum

More information

Unicel DxH 600 System

Unicel DxH 600 System SETUP MODULES Setup Unicel DxH 600 System Troubleshooting System Overview Additional Topics This document is not intended to replace the information in your Instrument Instructions for Use Manual (IFU).

More information

1%$6+2:7,0(*2/'(',7,21 1)/%/,7=*2/'(',7,21 &219(56,21.,7

1%$6+2:7,0(*2/'(',7,21 1)/%/,7=*2/'(',7,21 &219(56,21.,7 1%$6+2:7,0(*2/'(',7,21 1)/%/,7=*2/'(',7,21 &219(56,21.,7 C H A P T E R F I V E WIRING WARNING: Failure to reconnect ground wires or replace metal shields may result in radio frequency interference. NOTICE:

More information

Oxion. Microscopes for Life Sciences ENGLISH

Oxion. Microscopes for Life Sciences ENGLISH Oxion Microscopes for Life Sciences ENGLISH The Oxion series has been designed with all kind of Life Sciences applications and great durability in mind. This resulted in a modern, robust and high level

More information