E21 Alarm List E Photometric Data Error (A) 3117 Lamp Off Error 3118 Lamp Dark Error 3120 Sample Probe (FA) Error (Up-Down) (A, B)[A, B, C, D
|
|
- Hannah Stewart
- 6 years ago
- Views:
Transcription
1 E21 Alarm List E21-1 Alarm List Alarm List 3010 Text Not Received (ANL <- DPR) (A) 3020 Photometry Subunit Error 1 (A, B, C, D, E, F, G, H) 3021 Photometry Subunit Error 2 (A, B, C, D, E, F, G, H)[A, B, C, D, E] 3022 DPR Communication Error 1 (A, B, C, D, E, F, G, H) 3023 DPR Communication Error 2 (A, B, C, D, E, F, G, H)[A, B, C, D, E] 3024 Distributed Control Primary Station Error 1 (A, B, C, D, E, F, G, H) 3025 Distributed Control Primary Station Error 2 (A, B, C, D, E, F, G, H)[A, B, C, D, E] 3026 Distributed Control Secondary Station Error 1 (A, B, C, D, E, F, G, H) 3027 Distributed Control Secondary Station Error 2 (A, B, C, D, E, F, G, H)[A, B, C, D, E] 3028 Motor Controller Error 1 (A, B, C, D, E, F, G, H) 3029 Motor Controller Error 2 (A, B, C, D, E, F, G, H)[A, B, C, D, E] 3030 Barcode Reader Communication Error 1 (A, B, C, D, E, F, G, H) 3031 Barcode Reader Communication Error 2 (A, B, C, D, E, F, G, H)[A, B, C, D, E] 3032 ISE Control Error 1 (A, B, C, D, E, F, G, H) 3033 ISE Control Error 2 (A, B, C, D, E, F, G, H)[A, B, C, D, E] 3034 Thermal Control Error 1 (A, B, C, D, E, F, G) 3035 Thermal Control Error 2 (A, B, C, D, E, F, G)[A, B, C, D, E] 3036 I/O Control Error 1 (A, B, C, D, E, F, G, H) 3037 I/O Control Error 2 (A, B, C, D, E, F, G, H)[A, B, C, D, E] 3038 Power Failure Detect 3039 Reagent Refrigerator Temp. out of Range 3040 ISE Communication Error 1 (A, B, C, D, E, F, G, H) 3041 ISE Communication Error 2 (A, B, C, D, E, F, G, H)[A, B, C, D, E] 3042 Distributed Control Secondary Station Error 3 (A, B, C, D, E, F, G, H) 3100 DI Water Short 3101 DI Water Empty 3102 DI Water Overflow 3103 Detergent (Concentrated) Empty 3104 Detergent Short 3105 Detergent Empty 3106 Detergent Overflow 3107 Vacuum Tank Weak Pressure 3108 Vacuum Tank Full 3109 Concentrated waste water tank Full 3110 Washing waste water tank Full 3111 DI Water Supply Unavailable 3112 Detergent Supply Unavailable 3113 Cuvette Wheel (GA) Error (A)[A, B, C, D] 3114 Incubator Unit (GA) Temp. out of Range 3115 Photometry Unit (GB) Error (A)[A, B, C, D] E21 Alarm List e541e21.doc E21-1
2 E21 Alarm List E Photometric Data Error (A) 3117 Lamp Off Error 3118 Lamp Dark Error 3120 Sample Probe (FA) Error (Up-Down) (A, B)[A, B, C, D] 3121 Sample Probe (FA) Error (Rotation) (A, B)[A, B, C, D] 3122 Sample Probe (FA) Error (Liquid Sensor) (A)[A, B, C, D] 3123 Sample Probe (FA) Error (Clot Sensor) (A)[A, B, C, D] 3124 Sample Dispenser (SA-S) Error (A)[A, B, C, D] 3125 Inner Wash Dispenser (SA-W) Error (A)[A, B, C, D] 3127 R1 Reagent Probe (FD01) Error (Up-Down) (A, B)[A, B, C, D] 3128 R1 Reagent Probe (FD01) Error (Rotation) (A, B)[A, B, C, D] 3129 R1 Reagent Probe (FD01) Error (Liquid Sensor) (A)[A, B, C, D] 3130 R1 Reagent Dispenser (SA-R1) Error (A)[A, B, C, D] 3131 R1 Inner Wash Water Dispensing Disabled (A)[A, B, C, D] 3132 R2 Reagent Probe (FD11) Error (Up-Down) (A, B)[A, B, C, D] 3133 R2 Reagent Probe (FD11) Error (Rotation) (A, B)[A, B, C, D] 3134 R2 Reagent Probe (FD11) Error (Liquid Sensor) (A)[A, B, C, D] 3135 R2 Reagent Dispenser (SA-R2) Error (A)[A, B, C, D] 3136 R2 Inner Wash Water Dispensing Disabled (A)[A, B, C, D] 3137 S/R1 Mixing Unit (FC01) Error (Up-Down) (A)[A, B, C, D] 3138 S/R1 Mixing Unit (FC01) Error (Rotation) (A)[A, B, C, D] 3139 S/R1 Mixing Unit (FC01) Error (Mixing) (A)[A, B, C, D] 3140 R2 Mixing Unit (FC11) Error (Up-Down) (A)[A, B, C, D] 3141 R2 Mixing Unit (FC11) Error (Rotation) (A)[A, B, C, D] 3142 R2 Mixing Unit (FC11) Error (Mixing) (A)[A, B, C, D] 3143 Cuvette Wash Unit (FB) Error (A)[A, B, C, D] 3144 Cuvette Wash Water Dispensing Disabled (A)[A, B, C, D] 3145 R1 Reagent Refrigerator (DA01) Error (A)[A, B, C, D] 3146 R2 Reagent Refrigerator (DA11) Error (A)[A, B, C, D] 3147 STAT Table (DC) Error (A)[A, B, C, D] 3148 Second Washing Well Pouring Error (A) 3149 Second Washing Well Draining Error 3150 Cooling Unit (DB) Error (A) 3151 Detergent Supply Pump (P5) Error (A)[A, B, C, D] 3180 ISE Sequence Error (A, B, C, D) 3181 ISE A/D Unit Error (A, B, C, D) 3182 ISE Buffer Dispenser (SA-ISE) Error (A)[A, B, C, D] 3183 ISE Mixture Rolling Pump (IB-S) Error (A)[A, B, C, D] 3184 ISE MID Rolling Pump (IB-M) Error (A)[A, B, C, D] 3185 ISE Mixing Unit (ISE-MIX) Error (A)[A, B, C, D] E21 Alarm List e541e21.doc E21-2
3 E21 Alarm List E ISE Sample Pot Liquid Sensor Error (A)[A, B, C, D] 3187 ISE Sample Pot Overflow (A)[A, B, C, D] 3188 ISE Data Low 3189 ISE Analog Power Supply Error (A) 3190 ISE Conc value not calculated 3200 Sample Short (A, B, C, D, E, F, G, H, I, J) 3201 Sample Probe Clot Detect (A, B, C, D, E, F, G) 3203 Sample Probe Short Aspiration (A, B, C, D, E, F) 3204 Sample Probe Detergent Short (A) 3205 Sample Probe Detergent Empty (A) 3206 Sample Probe W2 Detergent Empty (A) 3208 Sample Prior Diluent Short (A) 3209 Sample Prior Diluent Run Out (A, B, C, D, E, F, G) 3210 Sample Prior Diluent Empty (A, B, C, D, E, F, G, H, I, J) 3211 R1 Reagent Short (A, B) 3212 R1 Reagent Run Out (A, B, C, D, E, F, G) 3213 R1 Reagent Empty (A, B, C, D, E, F, G, H, I, J, K) 3214 R1 Probe Detergent Short (A) 3215 R1 Probe Detergent Empty (A) 3216 R1 Probe W2 Detergent Short 3217 R2 Reagent Short (A, B) 3218 R2 Reagent Run Out (A, B, C, D, E, F, G) 3219 R2 Reagent Empty (A, B, C, D, E, F, G, H, I, J, K) 3220 R2 Probe Detergent Short (A) 3221 R2 Probe Detergent Empty (A) 3222 R2 Probe W2 Detergent Short 3223 R1 Reagent Refrigerator Cover Open 3224 R2 Reagent Refrigerator Cover Open 3225 STAT Table Large Cover Open 3226 STAT Table Small Cover Open 3230 Reagent Bottle Switch (A, B, C, D, E) 3231 No Reagent Bottle for RB/ACAL (A, B, C) 3232 Reagent Short for RB/ACAL/QC (A, B, C) 3233 STAT Sampling Interrupt (A) 3234 Reagent Refrigerator On Use 3235 RB/ACAL Sample Prior Diluent Short (A, B) 3240 Check the Tip of Sample Probe 3241 Check the Tip of R1 Reagent Probe 3242 Check the Tip of R2 Reagent Probe 3243 Sample Syringe Prime Incomplete 3250 ISE Cover Open 3251 ISE Buffer Solution Short 3252 ISE MID Solution Short E21 Alarm List e541e21.doc E21-3
4 E21 Alarm List E ISE REF Solution Short 3254 ISE Detergent Short 3255 ISE Serum Standard Solution H Short 3256 ISE Serum Standard Solution L Short 3257 ISE Urine Standard Solution H Short 3258 ISE Urine Standard Solution L Short 3259 ISE Electrode Check Liquid Na Short 3260 ISE Electrode Check Liquid K Short 3261 ISE CRS Standard Solution H Short 3262 ISE CRS Standard Solution M Short 3263 ISE CRS Standard Solution L Short 3264 ISE Pre-measure MID Solution Stability Error 3265 ISE MID Solution Stability Error (A) 3266 ISE Serum Standard Solution H Stability Error 3267 ISE Serum Standard Solution L Stability Error 3268 ISE Urine Standard Solution H Stability Error 3269 ISE Urine Standard Solution L Stability Error 3300 No Rack 3301 Sample ID Barcode Error (A) 3302 Reagent ID Barcode Error (A, B) 3500 DI Water Empty 3501 Detergent (Concentrated) Empty 3502 Detergent Empty 3503 Sample Probe (FA) Error (Up-Down) (A, B)[A, B, C, D] 3504 R1 Reagent Probe (FD01) Error (Up-Down) (A, B)[A, B, C, D] 3505 R2 Reagent Probe (FD11) Error (Up-Down) (A, B)[A, B, C, D] 3506 Detergent Overflow 3509 ISE Data Low 3510 Sample Probe Detergent Empty (A) 3511 Sample Prior Diluent Run Out (A, B, C, D, E, F, G) 3512 Sample Prior Diluent Empty (A, B, C, D, E, F, G, H, I, J) 3513 R1 Reagent Run Out (A, B, C, D, E, F, G) 3514 R1 Reagent Empty (A, B, C, D, E, F, G, H, I, J, K) 3515 R1 Probe Detergent Empty (A) 3516 R2 Reagent Run Out (A, B, C, D, E, F, G) 3517 R2 Reagent Empty (A, B, C, D, E, F, G, H, I, J, K) 3518 R2 Probe Detergent Empty (A) 3519 R1 Reagent Refrigerator Cover Open 3520 R2 Reagent Refrigerator Cover Open E21 Alarm List e541e21.doc E21-4
5 E21 Alarm List E STAT Table Large Cover Open 3522 STAT Table Small Cover Open 3524 ISE Cover Open 3525 Rack Supply Unit Cover Open 3526 Rack Sampling Lane Cover Open 3527 Rack Buffer & Repeat Lane Cover Open 3528 Repeat Lane Unit Cover Open 3529 Unremoval Rack in Rack Supply Unit (A) 3530 Unremoval Rack on Sampling Lane (A) 3531 Unremoval Rack in Rack Buffer Unit (A) 3532 Unremoval Rack in Rack Transfer Unit (A) 3533 Rack Storage Unit Full 3534 Rack Storage Unit Full 3535 STAT Sampling Interrupt 3536 Rack Kind Error 3537 Rack ID Barcode Error (A) 3538 Rack Supply Unit Cover Open 3539 Sample Probe (FA) Error (Liquid Sensor) (A)[A, B, C, D] 3540 R1 Reagent Probe (FD01) Error (Liquid Sensor) (A)[A, B, C, D] 3541 R2 Reagent Probe (FD11) Error (Liquid Sensor) (A)[A, B, C, D] 3542 R1 Reagent Refrigerator Cover Open 3543 R1 Reagent Refrigerator Cover Open 3544 R2 Reagent Refrigerator Cover Open 3545 R2 Reagent Refrigerator Cover Open 3546 STAT Table Large Cover Open 3547 STAT Table Large Cover Open 3548 ISE Cover Open 3549 ISE Cover Open 3550 ISE A/D Unit Error (A, B, C, D) 3551 DI Water Supply Unavailable 3600 Rack Supply Unit Cover Open 3601 Rack Sampling Lane Cover Open 3602 Rack Buffer & Repeat Lane Cover Open 3603 Repeat Lane Unit Cover Open 3604 Unremoval Rack in Rack Supply Unit (A) 3605 Unremoval Rack on Sampling Lane (A) 3606 Unremoval Rack in Rack Buffer Unit (A) 3607 Unremoval Rack in Rack Transfer Unit (A) 3608 Rack Storage Unit Full 3641 Rack Supply Unit (CB) Error (A)[A, B, C, D] 3642 Rack Supply Lever (CC) Error (A)[A, B, C, D] 3643 Shutter (CC) Error (A)[A, B, C, D] 3644 Routine Lane Lever 1 (CD) Error (A)[A, B, C, D] 3645 Routine Lane Lever 2 (CD) Error (A)[A, B, C, D] 3646 Rack Buffer Lever (CE) Error (A)[A, B, C, D] 3647 Rack Buffer Screen Lever (CE) Error (A)[A, B, C, D] 3648 Rack Retrieval Unit Lever 1 (CF) Error (A)[A, B, C, D] 3649 Rack Retrieval Unit Lever 2 (CF) Error (A)[A, B, C, D] E21 Alarm List e541e21.doc E21-5
6 E21 Alarm List E Rack Transfer Unit (CG) Error (A)[A, B, C, D] 3651 Repeat Lane Unit (CH) Error (A)[A, B, C, D] 3652 Rack Storage Unit (CJ) Error (A)[A, B, C, D] 3653 STAT Table (DC) Error (A)[A, B, C, D] 3654 Cup Detect Sensor Error (A) 3655 Routine Lane Rack Transfer Error (A) 3662 Reagent Bottle Illegal Setting (A, B, C) 3663 RB Incomplete 3664 ACAL Incomplete 3665 QC Incomplete 3666 Text ID Information Unmatched (A, B, C, D, E, F) 3667 ISE Daily Calibrator Illegal Setting 3668 Rack Kind Error 3669 Rack ID Barcode Error (A, B) 3670 Failed to Measure LIH (A, B, C, D, E) 3700 LAS->ANL Communication Retry (A, B) 3701 LAS->ANL Communication Error (A, B) 3702 LAS->ANL Illegal Message (A, B, C) 3703 ANL->LAS Communication Retry (A, B) 3704 ANL->LAS Communication Error (A, B) 3705 LAS S.ID. Read Error (A, B) 3706 Sample ID Information Unmatched (A, B) 3707 LAS Tube Transfer Error (A, B) 3708 Text ID Information Unmatched (DTS) (A, B, C, D, E, F) 3709 LAS->ANL Illegal Sequence Message (A, B) 3901 ANL Program Error (A, B, C)[A, B] 3902 ANL Program Error 1 (A, B, C, D)[A, B] 3903 ANL Program Error 2 (A, B, C, D, E)[A, B] 3904 ANL Program Error 3 (A, B, C, D, E, F)[A, B] 3905 ANL Mechanical Error (A, B, C)[A, B, C, D, E] 3906 ANL Mechanical Error 1 (A, B, C, D)[A, B, C, D, E] 3907 ANL Mechanical Error 2 (A, B, C, D, E)[A, B, C, D, E] 3908 ANL Mechanical Error 3 (A, B, C, D, E, F)[A, B, C, D, E] 3909 ANL Debug Information1 (A, B, C, D, E, F, G, H, I, J) 3910 ANL Debug Information2 (A, B, C, D, E, F) (A, B, C, D, E, F)[A, B] 5001 ANL PROGRAM DOWNLOAD COMPLETED 5002 INITIALIZE 5003 WARM UP 5004 STANDBY 5005 MEASURE START 5006 NO MORE SAMPLE RACKS 5007 MOVING TO PAUSE 5008 MOVING TO STOP MODE 5009 PAUSE 5010 STOP 5011 SYSTEM END E21 Alarm List e541e21.doc E21-6
7 E21 Alarm List E W1 START 5013 W2 START 5014 PHOTOCAL START 5015 W1 END 5016 W2 END 5017 PHOTOCAL END 5018 PHOTOCAL FAILURE 5031 INDEX UPDATED (A) 5032 INDEX DELETED (A) 5033 REACTION DATA DELETED (A) 5051 POWER ON 5090 LOGIN (A, B) 5091 LOGOUT (A, B) 5092 LOGIN FAILURE (A) 5093 PASSWORD CHANGE FAILURE (A) 5101 NO REAGENT BOTTLE (A, B, C, D) 5103 REAGENT ID READ ERROR (A, B) 5104 REAGENT ID READ ERROR (A, B) 5105 REAGENT ID NOT DEFINED (A, B, C) 5106 ILLEGAL REAGENT TYPE (A, B) 5107 R2 REAGENT FOUND IN THE R1 REFRIGERATOR (A, B, C) 5108 R1 REAGENT FOUND IN THE R2 REFRIGERATOR (A, B, C) 5109 ILLEGAL BOTTLE TYPE (A, B) 5110 ILLEGAL REAGENT POSITION (A, B) 5111 REAGENT EXPIRED (A, B, C) 5112 DIFFERENT LOT NO. REAGENT FOUND (A, B, C) 5114 REAGENT TYPE CONVERTED (A, B) 5115 BOTTLE TYPE CONVERTED (A, B) 5201 PHOTOCAL DATA ERROR (A) 5202 CUVETTE MEAN CHECK ERROR 5203 PHOTOCAL LAMP CHECK ERROR 5251 INCUBATION BATH TEMPERATURE HIGH 5252 INCUBATION BATH TEMPERATURE LOW 5253 REAGENT REFRIGERATOR TEMPERATURE HIGH 5254 REAGENT REFRIGERATOR TEMPERATURE LOW 5301 PANIC VALUE (A, B, C, D) 5302 HbA1c PRETREATMENT CHECK RANGE ERROR (A, B, C-D) E21 Alarm List e541e21.doc E21-7
8 E21 Alarm List E HbA1c% CALCULATION FAILED (A, B, C-D) 5304 NO COLOR DATA (A, B, C-D) 5305 NO BLANK DATA (A, B, C-D) 5306 RB DATA ERROR (A, B, C, D) 5307 CALIBRATION FACTOR RANGE OVER (A, B, C, D) 5308 CALIBRATION FACTOR RANGE UNDER (A, B, C, D) 5309 CALIBRATION OD RANGE OVER (A, B, C, D) 5310 CALIBRATION OD RANGE UNDER (A, B, C, D) 5311 CALIBRATION ERROR (A, B, C, D) 5312 MULTIPOINT-CAL. OD SLOPE CHECK ERROR (A, B, C, D) /2 POINT-CAL. CORRECTION FACTOR ERROR (A, B, C, D) 5314 QC DATA RANGE OVER (A, B, C, D) 5315 QC DATA RANGE UNDER (A, B, C, D) 5316 QC DATA MULTI-RULE CHECK ERROR (A, B, C, D, E) 5317 QC DATA DEVIATION CHECK ERROR (A, B, C, D) 5318 ISE CRS CALIBRATION FAILED (A, B, C-D) 5319 HbA1c LOT NO. UMMATCHED (A, B-C, D) 5401 NO SAMPLE CUP 5402 SAMPLE NOP (A, B-C, D) 5403 SAMPLE ID NOT FOUND (A, B,-C, D) 5404 NO TESTS REQUISITIONED (A, B,-C, D) 5405 MAXIMUM NUMBER OF SAMPLE (A, B-C, D) 5406 SAMPLE NO. CALCURATE ERROR (A-B) 5407 BROKEN LABEL (A-B,C) 5408 SAMPLE ID READ ERROR (A-B) 5409 MEASURE COMPLETED FOR THE READ SAMPLE ID (A-B,C) 5701 ILLEGAL MEDIA (A) 5702 FILE NOT FOUND (A) 5703 FILE WRITE ERROR (A) 5751 PRINTER NOT SELECTED 5752 PRINTER NOT AVAILABLE 5753 PART OF DATA IS NOT OUTPUT YET 5901 SHARED FILE UPDATE ERROR (A) 6001 STAT BARCODE READ ERROR (A) 6002 POSSIBLE TO SET CALIBRATOR AT STAT POSITION (A, B) 6003 POSSIBLE TO SET CONTROL AT STAT POSITION (A, B) 6004 BROKEN ID 6010 FAILED TO DELETE SAMPLE (A) E21 Alarm List e541e21.doc E21-8
9 E21 Alarm List E FAILED TO REQUISTION BECAUSE OF MAXIMUM SAMPLE NO NO CALIBRATION DATA (A, B, C) 6031 ONLINE ERROR (A)(B C D) 6032 ONLINE FORMAT ERROR 6033 ONLINE ILLEGAL TEXT CODE (A) 6034 ONLINE ILLEGAL TEXT BLOCK No. (A<->B) 6035 ONLINE ILLEGAL SAMPLE NO. (A B) C 6036 ONLINE ILLEGAL RACK NO. (A B:C-D) E 6037 ONLINE ILLEGAL SEX TEXT (A B:C) D 6038 ONLINE ILLEGAL AGE/MONTH (A B:C D) E 6039 ONLINE ANALYSIS METHOD MISMATCH (A B:C<>D) E 6040 ONLINE SAMPLE NO. MISMATCH (A B<>C D) E 6041 ONLINE RACK NO. MISMATCH (A B:C-D<>E-F) G 6042 ONLINE MISMATCH (A<>B) 6043 ONLINE TEST ITEM ERROR (A B) C 6044 ONLINE REPEAT ITEM ERROR (A B) 6500 OSV COMMUNICATION DATA ERROR (A B) 6501 OSV COMMUNICATION BUFFER FULL (A B) 6502 OSV COMMUNICATION TIMEOUT ERROR (A B) 6503 OSV FILE TRANSFER FOLDER FULL (A ) 6801 PrepLink COMMUNICATION ERROR (A B) 6802 CHEM ID NOT FOUND (A) 6803 CALCULATED TEST ERROR (A B) 8001 DPR-ANL COMMUNICATION ERROR (A, B) 8002 DPR-ANL ISE ERROR (A, B) 8003 DPR-ANL COMMUNICATION TIMEOUT (A) 8010 DIFFERENT VERSION OF FILE (A) 8100 PRINTER ERROR 8200 ILLEGAL HELP FILE (A) 8500 SAMPLE MANAGER EDIT (A,B,C) 8501 QC DATA EDIT (A,B,C,D,E) 9000 PROGRAM ERROR (***) 9001 PROGRAM INF (***) 9002 EXCEPTION ERROR 9003 NOT SEND (43) MESSAGE (***) 9999 DEBUG INF (***) E21 Alarm List e541e21.doc E21-9
Beckman Coulter System Reagent, AU400/AU400e URINE AMYLASE Cat. No.: OSR6x06 Reagent ID: 006
Beckman Coulter System Reagent, AU400/AU400e Test Name: AMY Type: Urine Operation: Yes Sample: Volume 2 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 200 L Dilution 0 L Min OD Max OD R2 Volume
More information4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system
Specifications & more > > System Specifications > > Consumables > > Accessories System Overview Cat. No. 16300 Analyzer type 4 plate fully automated ELISA analyzer Reagent system Open (Human tests predefined)
More informationBeckman Coulter System Reagent, AU400/AU400 e AMPHETAMINES EMIT II PLUS, Semi-Quantitative (500 ng/ml Cutoff) Cat. No.: OSR9C229 Reagent ID: 520
Beckman Coulter System Reagent, AU400/AU400 e Sample: Volume 3 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 150 μl Dilution 0 μl Min OD Max OD R2 Volume 65 μl Dilution 10 μl L 0.00 H 2.50
More informationLIGHT SOURCE Quartz-iodine lamp 12V-20W.
SPECIFICATIONS THROUGHPUT Up to 180 tests per hour; Up to 300 tests per hour with ISE unit. REAGENT SYSTEM Rotor with 24 positions for 25 ml bottles and 8 positions for 5 ml bottles. All positions can
More informationBeckman Coulter System Reagent, AU400/AU400 e ETHYL ALCOHOL EMIT II PLUS Cat. No.: OSR9K229 Reagent ID: 524
Beckman Coulter System Reagent, AU400/AU400 e Test Name: ETOH+ < > Type: Urine Operation: Yes Sample: Volume 4 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 210 μl Dilution 0 μl Min OD Max
More informationBICARBONATE (CO2), AU400/AU400 e System reagent: OSR6x37 Reagent ID: 037
BICARBONATE (CO2), AU400/AU400 e Test Name: CO2 < > Type: Serum Operation: Yes Sample: Volume 3 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 50 μl Dilution 210 μl Min OD Max OD R2 Volume 0
More information1 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (Max.) 1 plate /run Barcode reader
Specifications & more Elisys Uno > > System Specifications > > Consumables > > Accessories System Overview Cat.. 17350 Analyzer type 1 plate fully automated ELISA analyzer Reagent system Open (Human tests
More informationCOBAS INTEGRA 400 plus
COBAS INTEGRA 400 plus COBAS INTEGRA 400 plus is designed to consolidate testing and increase efficiency while reducing total running costs of the laboratory. The COBAS INTEGRA systems extensive assay
More informationQMS AMIKACIN ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800
Microgenics Corporation Part of Thermo Fisher Scientific QMS AMIKACIN ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800 Catalog No. 0373910 & 10017196 Intended for the
More informationCEDIA BARBITURATES APPLICATION Beckman Coulter AU480, AU680
CEDIA BARBITURATES APPLICATION Beckman Coulter AU480, AU680 Catalog No. 100084, 100093, 1661213, 10017365 Microgenics Corporation Part of Thermo Fisher Scientific Intended for the Qualitative and Semiquantitative
More informationCEDIA METHADONE APPLICATION Beckman Coulter AU480 & AU680
Microgenics Corporation Part of Thermo Fisher Scientific CEDIA METHADONE APPLICATION Beckman Coulter AU480 & AU680 Catalog No. 100088, 100097, 1730916 Intended for the Qualitative and Semiquantitative
More informationDRI METHADONE METABOLITE ASSAY APPLICATION BECKMAN COULTER AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800
Microgenics Corporation Part of Thermo Fisher Scientific DRI METHADONE METABOLITE ASSAY APPLICATION BECKMAN COULTER AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800 Catalog Nos. 100115 and 100116 Intended
More informationBeckman Coulter System Reagent, AU400/AU400 e ALKALINE PHOSPHATASE (IFCC) Cat. No.: OSR6x04 Reagent ID: 004
Beckman Coulter System Reagent, AU400/AU400 e Test Name: ALP < > Type: Serum Operation: Yes Sample: Volume 3 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 60 μl Dilution 60 μl Min OD Max OD
More informationBeckman Coulter System Reagent, AU400/AU400 e LITHIUM Cat. No.: OSRT056 Reagent ID: 600
Beckman Coulter System Reagent, AU400/AU400 e Test Name: Li < > Type: Serum Operation: Yes Sample: Volume 2 μl Dilution 0 μl Pre-Dilution Rate: 10 Reagents: R1 Volume 150 μl Dilution 0 μl Min OD Max OD
More informationBeckman Coulter System Reagent, AU400/AU400 e ACETAMINOPHEN EMIT tox TM Cat. No.: OSR7A229 Reagent ID: 517
Beckman Coulter System Reagent, AU400/AU400 e Test Name: ACETA Type: Serum Operation: Yes Sample: Volume 3 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 150 L Dilution 0 L Min OD Max OD R2 Volume
More informationBeckman Coulter System Reagent, AU400/AU400 e METHOTREXATE EMIT Cat. No.: SYVA 6L119 Reagent ID:
Beckman Coulter System Reagent, AU400/AU400 e METHOTREXATE EMIT Cat. No.: SYVA 6L119 Sample: Volume 3 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 162 μl Dilution 0 μl Min OD Max OD R2 Volume
More informationBeckman Coulter System Reagent, AU400/AU400 e THYROXINE (T4) Cat. No.: Microgenics Cat. No Reagent ID: #
Beckman Coulter System Reagent, AU400/AU400 e Cat. No.: Microgenics Cat. No. 0454 Test Name: T4 < > Type: Serum Operation: Yes Sample: Volume 4 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume
More informationDRI CREATININE-DETECT APPLICATION BECKMAN COULTER AU640, AU680
Microgenics Corporation Part of Thermo Fisher Scientific DRI CREATININE-DETECT APPLICATION BECKMAN COULTER AU640, AU680 Catalog No. 1797 Intended for the quantitative determination of creatinine in human
More informationDRI ETHYL ALCOHOL ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800
DRI ETHYL ALCOHOL ASSAY APPLICATION Beckman Coulter AU400, AU480, AU640, AU680, AU2700, AU5400, AU5800 Catalog No. 0037, 0038 Intended for the quantitative determination of alcohol in human urine, serum
More informationDRI ph-detect APPLICATION BECKMAN COULTER AU640, AU680
Microgenics Corporation Part of Thermo Fisher Scientific DRI ph-detect APPLICATION BECKMAN COULTER AU640, AU680 Catalog No. 100054 Intended for the determination of urine ph. For In Vitro Diagnostic Use
More informationBeckman Coulter System Reagent, AU400/AU400 e URINE GLUCOSE Cat. No.: OSR6x21 Reagent ID: 021
Beckman Coulter System Reagent, AU400/AU400 e Test Name: GLU Type: Urine Operation: Yes Sample: Volume 3 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 50 L Dilution 150 L Min OD Max OD R2 Volume
More informationBeckman Coulter System Reagent, AU400/AU400 e URINE CALCIUM ARSENAZO Cat. No.: OSR6x117 Reagent ID: 117
Beckman Coulter System Reagent, AU400/AU400 e Test Name: CALA Type: Urine Operation: Yes Sample: Volume 2.0 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 25 L Dilution 225 L Min OD Max OD R2
More informationDRI OXYCODONE APPLICATION BECKMAN COULTER AU480, AU680, AU5800
Microgenics Corporation Part of Thermo Fisher Scientific DRI OXYCODONE APPLICATION BECKMAN COULTER AU480, AU680, AU5800 Catalog No. 100248, 100249, 10015632 The DRI Oxycodone Enzyme Immunoassay is intended
More informationBeckman Coulter System Reagent, AU400/AU400 e URINE CREATININE Cat. No.: OSR6x78 Reagent ID: 078
Beckman Coulter System Reagent, AU400/AU400 e Test Name: CRE < > Type: Urine Operation: Yes Sample: Volume 8 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 120 μl Dilution 90 μl Min OD Max OD
More informationFULLY AUTOMATED 2 MICROPLATE ANALYZER
FULLY AUTOMATED 2 MICROPLATE ANALYZER The new Personal Lab,(Plab) is an integration between our unique extensive expertise and information gathered from thousands of installations. The new Plab is innovative
More information4. Specifications and Additional Information
4. Specifications and Additional Information AGX52004-1.0 8B/10B Code This section provides information about the data and control codes for Arria GX devices. Code Notation The 8B/10B data and control
More informationCIS-331 Exam 2 Fall 2015 Total of 105 Points Version 1
Version 1 1. (20 Points) Given the class A network address 117.0.0.0 will be divided into multiple subnets. a. (5 Points) How many bits will be necessary to address 4,000 subnets? b. (5 Points) What is
More informationCIS-331 Fall 2014 Exam 1 Name: Total of 109 Points Version 1
Version 1 1. (24 Points) Show the routing tables for routers A, B, C, and D. Make sure you account for traffic to the Internet. Router A Router B Router C Router D Network Next Hop Next Hop Next Hop Next
More informationBA-88A Semi-auto Chemistry Analyzer
BA-88A Semi-auto Chemistry Analyzer Main Contents Features Working principles Improvements from BA-88 Competitors Operation Price FAQ Features Test mode: flowcell or cuvette 7.0 TFT touch screen & popup
More informationThe NGAL Test Application Note for Abbott Architect c8000
The NGAL Test Application Note for Abbott Architect c8 General parameters Name: NGAL Assay number: *1 Assay version: 1 Assay type: Photometric Assay availability: Enabled Cal version: 1 Reaction definition
More informationEasyElectrolytes. With EasyElectrolytes, Medica has redefined electrolyte analyzer design
EasyElectrolytes With EasyElectrolytes, Medica has redefined electrolyte analyzer design Simple yes/no prompted operation, combined with a modular design makes EasyElectrolytes reliable and economical.
More informationSPA III Quick Reference Guide for Custom Panels
SPA III Quick Reference Guide for Custom Panels This guide contains instructions for using the BD FACS Sample Prep Assistant III (SPA III) with BD FACS SPA software version.0 and later. Initial Setup Custom
More informationModbus Register Map: InRow ACRD60x / ACRC60x
Modbus Map: InRow ACRD60x / ACRC60x Notes: 1. 16-bit registers (INT16, UINT16, ENUM) are transmitted MSB first (i.e., big-endian). 2. INT32 and UINT32 are most-significant word in n+0, least significant
More informationCIS-331 Fall 2013 Exam 1 Name: Total of 120 Points Version 1
Version 1 1. (24 Points) Show the routing tables for routers A, B, C, and D. Make sure you account for traffic to the Internet. NOTE: Router E should only be used for Internet traffic. Router A Router
More informationSkyla VB1 Quick Reference Guide
Skyla VB1 Quick Reference Guide 1 VB1 DM/JAC 2014 v1.0 Quick Reference Guide Contents External features of the analyser 3 VB1 Function Buttons 4 Testing a Sample 5 How to reconstitute a biochemistry control
More informationDimension EXL 200 Integrated Chemistry System Technical Specifications
Dimension EXL 200 Integrated Chemistry System Technical Specifications Overview The Dimension EXL 200 Integrated Chemistry System offers revolutionary chemiluminescent technology and automated, productivity-enhancing
More informationGEMINI. Compact Microplate Processor. System Guide
GEMINI Compact Microplate Processor System Guide 1 Gemini System Guide Table of Contents 1. Introduction 3 2. User Levels 4 3. Instrument Components & Accessories 6 4. Basic Operation - Quick Guide: 1-Lane
More informationAPPENDIX A: ERROR CODES
APPENDIX A: ERROR 20001 Unable to load a Remove and replace cassette Check the micro-switch located on the inside left wall of the 20002 Low Cash. Replenish the cash If using less than 75 bills, disable
More informationRegister Map: Ecoflair Indirect Air Economizer
Register Map: Ecoflair Indirect Air Economizer Notes: 1. 16-bit registers (INT16, UINT16, ENUM) are transmitted MSB first (i.e., big-endian). 2. INT32 and UINT32 are most-significant word in n+0, least
More informationBCA protein assay kit for low concentrations. For measuring total protein concentration of pure proteins, extracts or lysates.
ab207002 BCA protein assay kit for low concentrations Instructions for use: For measuring total protein concentration of pure proteins, extracts or lysates. This product is for research use only and is
More informationGenmega ATM Error Codes
Genmega ATM Error Codes Code Description Remedy 20001 Unable to load a cassette. Remove and replace cassette - Check the micro-switch located on the inside left wall of the 20002 Low Cash. "Low Cash Warning"
More informationMicroplate Readers INSTRUMENTS. Description Catalog # Description DAR800 SF2100 SF4700
Microplate Readers DAR800 As a stand-alone Microplate reader, the DAR800 is designed for applications within the clinical, biotechnology and research areas. The onboard data reduction surpasses many computer
More informationWIZ Panel SOFTWARE OPERATING MANUAL. Verified: TM X
WIZ Panel SOFTWARE OPERATING MANUAL Manual Version Software version Prepared: Sysmedia Verified: TM Checked: QM Approved: MD Issued: 1.0 9.0X SOFWARE DESIGNED AND DEVELOPED BY: SYSMEDIA Srl Via Anoia,
More informationElectrolyte analyzer i-smart 30
Electrolyte analyzer i-smart 30 Overview i-sens electrolyte analyzer, i-smart 30 uses 60 μl of blood sample to measure ions such as Na+, K+, Cl- and hematocrit automatically. Unlike other competitors products,
More informationEDR Report Information
EDR Report File Information Value VIN 5YJXCDE20HF041782 Retrieval Date 2017/06/30 02:16:00 (UTC) Retrieval User Comments Retrieval Program Information EDR Report Information Tesla EDR Reporting Service
More informationDigital Projector X30N/X35N
Digital Projector X30N/X35N Operator's Guide TECHNICAL Warranty 3M warrants that when the 3M Product is used according to 3M s Intended Use Statement (www.3m.com/meetings), it will perform satisfactorily
More informationProducts for Health Care
www.medicacorp.com \EDIC@ Products for Health Care easy inside and out Medica s EasyStat analyzer measures ph, PCO 2, PO 2, Na +, K +, Ca ++, and Hct and calculates additional parameters. Patient parameters,
More informationCIS-331 Spring 2016 Exam 1 Name: Total of 109 Points Version 1
Version 1 Instructions Write your name on the exam paper. Write your name and version number on the top of the yellow paper. Answer Question 1 on the exam paper. Answer Questions 2-4 on the yellow paper.
More informationC1098 JPEG Module User Manual
C1098 JPEG Module User Manual General Description C1098 is VGA camera module performs as a JPEG compressed still camera that can be attached to a wireless or PDA host. Users can send out a snapshot command
More informationThe NGAL Test Application Note for Roche Modular P
The NGAL Test Application Note for Roche Modular P NGAL Code (ACN) xxx ANALYZE Ser/Pl type Assay/Time/Point 2-Point-End 1 18 34 Wave (2nd/Primary) 8 57 Volume Reagent Vol. Diluent BCN OBS Timing Normal
More informationPerkinElmer Series 200 HPLC: Operating Procedure
PerkinElmer Series 200 HPLC: Operating Procedure Chem Eng 5503 Version 1.01 Last Update 8/9/07 This document outlines the basic operating procedure for the PE series 200 HPLC, UV/Vis and SEDEX Light Scattering
More informationCP-X253. User's Manual (detailed) Technical. Example of PC signal. Projector
Projector CP-X253 User's Manual (detailed) Technical Example of PC signal Resolution (H x V) H. frequency (khz) V. frequency (Hz) Rating Signal mode 720 x 400 37.9 85.0 VESA TEXT 640 x 480 31.5 59.9 VESA
More informationExample of PC signal. Projector CP-X2010/CP-X2510/CP-X3010 User's Manual (detailed) Operating Guide Technical
Projector CP-X2010/CP-X2510/CP-X3010 User's Manual (detailed) Operating Guide Technical Example of PC signal Resolution (H x V) H. frequency (khz) V. frequency (Hz) Rating Signal mode 720 x 400 37.9 85.0
More informationNEW IMPROVED SCREENING PLATFORM MATERNAL FETAL HEALTH
Introducing the new AutoDELFIA immunoassay system for prenatal screening Brochure not for distribution in the USA NEW IMPROVED MATERNAL FETAL HEALTH SCREENING PLATFORM ALREADY 60 MILLION PREGNANCIES SCREENED
More informationParallax Serial LCD 2 rows x 16 characters Non-backlit (#27976) 2 rows x 16 characters Backlit (#27977) 4 rows x 20 characters Backlit (#27979)
599 Menlo Drive, Suite 100 Rocklin, California 95765, USA Office: (916) 624-8333 Fax: (916) 624-8003 General: info@parallax.com Technical: support@parallax.com Web Site: www.parallax.com Educational: www.stampsinclass.com
More informationCIS-331 Exam 2 Fall 2014 Total of 105 Points. Version 1
Version 1 1. (20 Points) Given the class A network address 119.0.0.0 will be divided into a maximum of 15,900 subnets. a. (5 Points) How many bits will be necessary to address the 15,900 subnets? b. (5
More informationTrio Application Control System Instruction Sheet
Trio Application Control System Instruction Sheet P/N 7580708_01 CAUTION The procedures detailed within this guide should only be performed by trained Nordson personnel or by persons cleared to do so by
More informationX64. Operator's Guide TECHNICAL. Example of PC signal
X64 Operator's Guide TECHNICAL Example of PC signal Resolution (H x V) H. frequency (khz) V. frequency (Hz) Rating Signal mode 720 x 400 37.9 85.0 VESA TEXT 640 x 480 31.5 59.9 VESA VGA (60Hz) 640 x 480
More informationA 2 O Advanced Automated Osmometer
A 2 O Advanced Automated Osmometer A fully automated, multi-sample osmometer that sets the new benchmark for analytical performance, ease of use, and true walkaway operation. www.aicompanies.com/a2o The
More information6.1 Font Types. Font Types
6 Font This chapter explains basic features of GP-Pro EX's "Font" and basic ways of placing text with each font. Please start by reading "6.1 Font Types" (page 6-2) and then turn to the corresponding page.
More informationOperating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University
Operating Manual High Performance Liquid Chromatograph Agilent 1100 ; VWD, DAD, FLD and RID Scientific Equipment Center, Prince Of Songkla University Operating Manual High Performance Liquid Chromatograph
More informationDSX Automated ELISA System
DSX Automated ELISA System Operator s Manual For Revelation 6.0 and above IMPORTANT Please read carefully before using the DSX ii Revision History Revision Date: September 19, 2005 12-16-2005 Part No.
More informationThe cache is 4-way set associative, with 4-byte blocks, and 16 total lines
Sample Problem 1 Assume the following memory setup: Virtual addresses are 20 bits wide Physical addresses are 15 bits wide The page size if 1KB (2 10 bytes) The TLB is 2-way set associative, with 8 total
More informationTK4S temperature controller
TK4S temperature controller Table of Contents Thank Purchase Instructions... iii Manual Guide... iv Communication protocols... v Table of Contents... vii 1 Modbus RTU Protocols... 1.1 Read Coil Status(Func01
More informationAPPLESHARE PC UPDATE INTERNATIONAL SUPPORT IN APPLESHARE PC
APPLESHARE PC UPDATE INTERNATIONAL SUPPORT IN APPLESHARE PC This update to the AppleShare PC User's Guide discusses AppleShare PC support for the use of international character sets, paper sizes, and date
More informationDigital Projector X30 Operator's Guide TECHNICAL
Digital Projector X30 Operator's Guide TECHNICAL Example of PC signal Resolution (H x V) H. frequency (khz) V. frequency (Hz) Rating Signal mode 720 x 400 37.9 85.0 VESA TEXT 640 x 480 31.5 59.9 VESA VGA
More informationProduct Correction Urgent Immediate Action Required
Abbott GmbH & Co. KG Max Planck Ring 2 65205 Wiesbaden, Germany DIAGNOSTICS Urgent Field Safety Notice Product Correction Urgent Immediate Action Required Date d March 8, 2019 Product Product Name List
More informationFieldServer Driver FS Heatcraft-Smart Controller II
Description FieldServer Driver FS-8700-100 Heatcraft-Smart Controller II The FieldServer Heatcraft Smart Controller II (HCSCII) driver has the following functionality: 1) Status monitoring of Heatcraft
More informationCDR File Information. Comments Direct PCM
IMPORTANT NOTICE: Robert Bosch LLC and the manufacturers whose vehicles are accessible using the CDR System urge end users to use the latest production release of the Crash Data Retrieval system software
More informationHumaStar 300 Service Manual
HumaStar 300 Service Manual Cat No. 17901s/2 Revision list of the Manual Rev. /DATE. REVISION DESCRIPTION System Version Copyright Copyright 2010, Human GmbH, Wiesbaden, Germany. All rights reserved.
More informationData Sheet. Item Specification Comment
1 (14) Dokumentnamn/Document name Data Sheet Dokumentnummer/Document number Physical Specifications Doc.no. 544753 Ver. 2.0 1(15) Instrument Width: 680 mm Depth: 600 mm Height: 440 mm Packed instrument
More informationS5-115U. Application
S5-115U Application S5-115U Design Central configuration Distributed configuration Note General technical specifications S5-115U Principle of operation Program memory Processor Programming S5-115U Cyclic
More informationCSCI 220: Computer Architecture I Instructor: Pranava K. Jha. Simplification of Boolean Functions using a Karnaugh Map
CSCI 22: Computer Architecture I Instructor: Pranava K. Jha Simplification of Boolean Functions using a Karnaugh Map Q.. Plot the following Boolean function on a Karnaugh map: f(a, b, c, d) = m(, 2, 4,
More information2-Type Series Pressurized Closures
2-Type Series Pressurized Closures A complete pressure tight reenterable closure system for enclosing spliced connections of communications cables in a wide variety of applications. The 2-type Closure
More informationGateway Ascii Command Protocol
Gateway Ascii Command Protocol Table Of Contents Introduction....2 Ascii Commands.....3 Messages Received From The Gateway....3 Button Down Message.....3 Button Up Message....3 Button Maintain Message....4
More informationDissolution System Drivers Operation Manual Rev. D
Dissolution System Drivers Operation Manual 81-200-807 Rev. D Hanson Research Corporation 9810 Variel Avenue Chatsworth, CA 91311 USA (800) 821-8165 (818) 882-7266 FAX (818) 882-9470 www.hansonresearch.com
More informationSPAREPARTSCATALOG: CONNECTORS SPARE CONNECTORS KTM ART.-NR.: 3CM EN
SPAREPARTSCATALOG: CONNECTORS ART.-NR.: 3CM3208201EN CONTENT SPARE CONNECTORS AA-AN SPARE CONNECTORS AO-BC SPARE CONNECTORS BD-BQ SPARE CONNECTORS BR-CD 3 4 5 6 SPARE CONNECTORS CE-CR SPARE CONNECTORS
More information6. Specifications & Additional Information
6. Specifications & Additional Information SIIGX52004-3.1 Transceier Blocks Table 6 1 shows the transceier blocks for Stratix II GX and Stratix GX deices and compares their features. Table 6 1. Stratix
More informationFast Facts. for Operating the scil Vet abc Plus. Hematology Chemistry Digital Radiography Ultrasound Orthopedics Education
Fast Facts for Operating the scil Vet abc Plus Hematology Chemistry Digital Radiography Ultrasound Orthopedics Education SCIL Vet ABC Plus Fast Facts Table of Contents Start Up Cycle pg. 2 Reagents Status
More informationZN-DN312XE-M Quick User Guide
ZN-DN312XE-M Quick User Guide This manual provides instructions for quick installation and basic configuration of your IP device. Step1. Connect cables to IP device Connect required cables to the device
More information10. RS-232C communication
10. RS-232C communication PB9200(P5XMLA) Connecting the cable (1) Turn off the projector and the computer power supplies. (2) Connect the CONTROL port of the projector with a RS-232C port of the computer
More informationTriple DES and AES 192/256 Implementation Notes
Triple DES and AES 192/256 Implementation Notes Sample Password-to-Key and KeyChange results of Triple DES and AES 192/256 implementation For InterWorking Labs customers who require detailed information
More informationAccessories for MVA 13
Accessories for MVA 13 Below, the accessories are grouped into Scope of delivery and Optional accessories. Please keep this printout at hand for ordering replacement material. These lists may be subject
More informationCIS-331 Final Exam Spring 2015 Total of 115 Points. Version 1
Version 1 1. (25 Points) Given that a frame is formatted as follows: And given that a datagram is formatted as follows: And given that a TCP segment is formatted as follows: Assuming no options are present
More informationTechnical Procedure for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) for Gunshot Residue Analysis
Technical Procedure for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) for Gunshot Residue Analysis 1.0 Purpose This technical procedure shall be followed for the operation of the Inductively Coupled
More informationCP-D10. User's Manual (detailed) Operating Guide Technical. Example of PC signal. Projector
Projector CP-D10 User's Manual (detailed) Operating Guide Technical Example of PC signal Resolution (H x V) H. frequency (khz) V. frequency (Hz) Rating Signal mode 720 x 400 37.9 85.0 VESA TEXT 640 x 480
More informationSPARE CONNECTORS KTM 2014
SPAREPARTSCATALOG: // ENGINE ART.-NR.: 3208201EN CONTENT CONNECTORS FOR WIRING HARNESS AA-AN CONNECTORS FOR WIRING HARNESS AO-BC CONNECTORS FOR WIRING HARNESS BD-BQ CONNECTORS FOR WIRING HARNESS BR-CD
More informationCIS-331 Final Exam Spring 2018 Total of 120 Points. Version 1
Version 1 Instructions 1. Write your name and version number on the top of the yellow paper and the routing tables sheet. 2. Answer Question 2 on the routing tables sheet. 3. Answer Questions 1, 3, 4,
More informationTissue-Tek Genie. Full Automation, True Random Access For IHC and ISH. Advanced Staining System. continuous innovation for pathology
Advanced Staining System Full Automation, True Random Access For IHC and ISH continuous innovation for pathology Predictable Speed with Maximum Flexibility Introducing the Tissue-Tek Genie Advanced Staining
More informationAppendix 1: DataStudio with ScienceWorkshop Sensors Tech Tips
Appendix 1: DataStudio with ScienceWorkshop Sensors Tech Tips Section 1: Starting an experiment 1.1 Opening a file 1. Open the File menu and select Open Activity. 2. In the Open dialog box, navigate to
More informationUNH-IOL MIPI Alliance Test Program
DSI Receiver Protocol Conformance Test Report UNH-IOL 121 Technology Drive, Suite 2 Durham, NH 03824 +1-603-862-0090 mipilab@iol.unh.edu +1-603-862-0701 Engineer Name engineer@company.com Panel Company
More informationACL 9000 Service Manual P/N Revision 0 October 2000
ACL 9000 Service Manual P/N 00079990-00 Revision 0 October 2000 Instrumentation Laboratory S.P.A Viale Monza 338 20128 Milano (Italia) ACL 9000 Service Manual Foreword This Service Manual contains the
More informationintellipath Research Software Manual
intellipath Research Software Manual www.biocare.net Biocare Medical Technical Support: 800-799-9499 Option 3 Customer Service: 800-799-9499 Fax: 925-603-8080 Corporate Office: 4040 Pike Lane Concord,
More informationYour Test Your Workflow Your Freedom. Automated Staining Instrument. Freedom
Flexibility Your Test Your Workflow Your Freedom Automated Staining Instrument Freedom www.biocare.net www.slidestainer.com Enjoy the Freedom of Maximum Flexibility & Productivity Reagent Rack Cold Station
More informationProtein Quantification Kit (BCA Assay)
Protein Quantification Kit (BCA Assay) Booklet Item NO. KTD3001 Product Name Protein Quantification Kit (BCA Assay) ATTENTION For laboratory research use only. Not for clinical or diagnostic use Version
More informationEdif Instruments Srl - ECHO CONSUMABLES CATALOGUE rel.1.2. EE0201B Standard host cable (ECHO XPC Windows)
EE0201B Standard host cable (ECHO XPC Windows) EE0202B Power cord SCHUKO90-VDE 2m EE0203B Null modem host cable (ECHO PC Dos, PLUS) EI0102A Heating reel assembly EI0103A Complete optical group ECHO, with
More informationS5-115U. Application
S5-115U S5-115U Design Central configuration Distributed configuration Note General technical specifications S5-115U Principle of operation Program memory Processor Programming S5-115U Cyclic program execution
More informationSTAINING PROTOCOL FOR CYTOMETRY (Réf LabEx #1)
STAINING PROTOCOL FOR CYTOMETRY (Réf LabEx #1) Aim To provide detailed description of all steps, material and methods used for fluorescent surface staining and preparation of whole blood cells for analysis
More informationeprep Sample Preparation Workstation
eprep Sample Preparation Workstation Robotic Sample Preparation for the Chromatography Laboratory Easy, precise and affordable workflow automation Area (mau*min) Highly Flexible and Adaptable The eprep
More informationMEDICAL INSTRUMENTS. AVL 9120, 9130, 9140, 9180, 9181 Electrolyte Analyzers. Service Manual
MEDICAL INSTRUMENTS AVL 90, 90, 90, 980, 98 Electrolyte Analyzers Service Manual Tenth Edition vember 99 Copyright, 99, AVL Scientific Corporation. All rights reserved. Unless otherwise noted, no part
More information