Catalog Number A, up to two ACs max (F-, G-Frame) Number of Poles. Rating (Frame) (D-Frame) 400 (E-Frame)
|
|
- Neil Cox
- 5 years ago
- Views:
Transcription
1 .0 R9 Series (UL 98) Non-Fusible 00 00A Auxiliary Contacts Terminal Screens Line and Load Terminal Lugs Maximum Ampere Rating (Frame) Notes Early-break/same-make. Gold plated for minimal resistance for PLC applications. Requires use of ACHFG auxiliary contact holder for F- and G-Frame switches. For two-hole lug, consult factory. (Frame) of AC AC Type Catalog 00 00A, up to two ACs max NO / NC Standard ACNONCDE 00A, up to two ACs max. (D-, E-Frame) NO / NC Low Level ACNONCDELL A, up to four ACs max (F-, G-Frame) Auxiliary contact holder (for use with ACNOR9 and ACNCR9) Line and load protection against direct contact with terminals or connection parts. Line side terminal shrouds are included standard on A non-fusible switches. Shrouds are not included on the 00 00A. Connection of copper cables on to the terminals (no spade lugs). Each kit includes lugs for line or load side. For line and load side, order two kits. For dimensions, see Page (F-, G-Frame) Maximum Ampere Rating (Frame) (D-Frame) 00 (E-Frame) 600 (F-Frame) (G-Frame) (D-Frame) 00 (E-Frame) 600 (F-Frame) (G-Frame) NO / NC Standard ACNONCDE NO / NC Low Level ACNONCDELL NO Standard ACNOR9 NC Standard ACNCR9 ACHFG of Poles Line/Load Side Catalog Line TSR9DT Load TSR9DB Line or load TSR9DTB Line TSR9ET Load TSR9EB Line or load TSR9ETB Line or load TSR9F Line or load TSR9F Line or load TSR9G Line or load TSR9G of Poles of Lugs/Pole Lug Capacity/ Phase Cable Type Catalog #6 00 kcmil Cu/Al LKR9DL #6 00 kcmil Cu/Al LKR9DL # 600 kcmil Cu/Al LKR9EM # 600 kcmil Cu/Al LKR9EM () # 600 kcmil Cu/Al LKR9FN () # 600 kcmil Cu/Al LKR9FN x () # 600 kcmil Cu/Al LK6R9G x () # 600 kcmil Cu/Al LK8R9G Switching Devices PG008000E September 0
2 .0 R9 Series (UL 98) Non-Fusible 00 00A Technical Data and Specifications UL and CSA Characteristics Technical Characteristics 00A 00A 00A 600A 800A 000A 00A Short circuit rating at 600 Vac (ka) 00 ka 00 ka 00 ka 00 ka 00 ka 00 ka 00 ka Fuse type J J J J L L L Maximum fuse rating (A) Maximum Horsepower Rating/Maximum Motor FLA Three-Phase 0 0 Vac 0/80 75/9 5/ 00/80 00/80 00/80 00/ Vac 75/96 50/80 50/0 00/77 500/ / / Vac 00/99 00/9 50/6 50/6 500/7 500/7 500/7 Maximum Horsepower Rating/Maximum Motor FLA Direct Current 5 Vdc Two-pole in series 0/76 5/ 0/8 0/8 50 Vdc Three-pole in series 5/55 5/55 50/7 50/7 Connection Minimum connection section/awg #6 #6 # x # x # x # x # Maximum connection section/awg 00 kcmil 00 kcmil 600 kcmil x 600 kcmil x 600 kcmil x 600 kcmil x 600 kcmil Auxiliary Contacts Electrical characteristics A00 A00 A00 A600 A600 A600 A600 IEC Characteristics Technical Characteristics 00A 00A 00A 600A 800A 000A 00A Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Rated Operational Currents I e (A) Rated Voltage Notes Load Duty Category A A A A A A A 00 Vac AC- A Vac AC- A Vac AC- A Vac AC- A Connection Minimum Cu cable cross section (mm ) x 50 x 85 x 0 Minimum Cu busbar section (mm ) x 0 x 5 x 0 x 5 x 50 x 5 x 60 x 5 Operational Power in Ac- (kw) At 00 Vac without prebreaking AC in AC (kw) ( x ) At 500 Vac without prebreaking AC in AC (kw) ( x ) At 690 Vac without prebreaking AC in AC (kw) ( x ) Overload Capacity (U e 5 Vac) Rated short-circuit making capacity Icm (ka peak) Short-circuit rating achieved when used with respective fuse type and maximum fuse rating. Category with index A = frequent operation. For a rated operating voltage, U i = 00 Vac. Switching Devices PG008000E September 0
3 .0 R9 Series (UL 98) Non-Fusible 00 00A Dimensions Approximate Dimensions in Inches (mm) Front Operation D- and E-Frames R9 Series Non-Fusible 00 00A V K CA Ampere Rating (A) Overall Dimensions In (mm) Terminal Shrouds Switch Body AC AD F P F P H J P J P K 00.7 (9.6) 0.0 (56.0).05 (77.5) 7.09 (80.0) 9.06 (0.0). (07.0).7 (55.0). (05.0).80 (5.6) 00.7 (9.6) 0.0 (56.0).05 (77.5) 7.09 (80.0) 9.06 (0.0). (07.0).7 (55.0). (05.0).80 (5.6) 00.9 (8.0) 6.00 (06.0).5 (5.0) 9.05 (0.0).0 (90.0) 6.5 (66.0).95 (75.0) 5. (5.0).65 (67.5) Ampere Rating (A) J T M F U W R N R AA AC H Switch Mounting Connection M P M P N R R T U V W Y Z AA AC (60.0) 8.7 (0.0) 5. (5.0) 0.5 (9.0) 0.7 (7.0).97 (50.0) 0.98 (5.0).8 (0.0) 0. (.0) 0. (.5).5 (.) 6.0 (60.0) 0.60 (5.0) (60.0) 8.7 (0.0) 5. (5.0) 0.5 (9.0) 0.7 (7.0).97 (50.0) 0.98 (5.0).8 (0.0) 0. (.0) 0. (.5).5 (.) 6.0 (60.0) 0.60 (5.0) (0.0) 0.60 (70.0) 7.67 (95.0) 0.5 (9.0) 0.7 (7.0).56 (65.0).77 (5.0).97 (50.0) 0. (.0) 0.0 (5.0).08 (5.0) 0.0 (60.0) 0.80 (0.0) Z Y AD C Eaton The switch will operate correctly when rotated clockwise 90 degrees. The switch will not operate correctly when rotated counterclockwise 90 degrees. Switching Devices PG008000E September 0 5
4 .0 R9 Series (UL 98) Non-Fusible 00 00A Approximate Dimensions in Inches (mm) Front Operation F- and G-Frames R9 Series Non-Fusible 600A Terminal Screens Switch Body Switch Mounting Connection Terminals AC F P F P H J P J P M P M P N N AA Z 8. (60.0).0 (80.0).7 (60.0) 5.5 (0.0) 5.00 (7.5) 6.59 (67.5) 0.0 (55.0).9 (5.0) 6.89 (75.0). (59.5).6 (0.0).85 (7.0) R9 Series Non-Fusible A Z H H Z AC AC 0.78 (9.8) 0.78 (9.8).57 (0.0) J Ø0. (Ø0.9) F 8.85 (.8) Y X M.5 (80.0) J.7 (9.9) Ø0.5 (Ø.0) Terminal Screens Switch Body Switch Mounting Connection Terminals AC F P F P H J P J P M P M P N N N Z M Y X 8. (60.0).6 (7.0) 9.7 (9.0) 5.5 (0.0) 6.8 (7.5) 9.9 (.5).66 (7.0) 8.8 (67.0) 6.89 (75.0). (59.5).0 (8.0).85 (7.0) N F N AA N N N Eaton The switch will operate correctly when rotated clockwise 90 degrees. The switch will not operate correctly when rotated counterclockwise 90 degrees. Eaton The switch will operate correctly when rotated clockwise 90 degrees. The switch will not operate correctly when rotated counterclockwise 90 degrees. 6 Switching Devices PG008000E September 0
5 .0 R9 Series (UL 98) Non-Fusible 00 00A Approximate Dimensions in Inches (mm) Direct Handle Front Operation R9 Series Non-Fusible 00A R9 Series Non-Fusible A.57 (0.0) Door Interlocked External Handle PH Type Handle PH Type Handle PH Type Handle Direction of Operation I Door Drilling Templates.57 (0.0) Ø.6 (7.0) 5. (5.0) Ø.07 (Ø78.0).9 (5.0).77 (5.0).79 (5.5) Top and Bottom Terminal Lugs.6 (60.0) Ø.07 (Ø78.0) 7.8 (90.0) R9 Series Non-Fusible 00 00A R9 Series Non-Fusible 00A R9 Series Non-Fusible A.5 (8.6) 90 0 Ø7.0 (8.0) 0.5 (Ø.).00 (5.). (8.) I.57 (0.0) Ø.6 (7.0).0 (5.0).80 (6.0) (7.5) Ø7.0 (8.0).5 (85.0) 8.7 (0.0).0 (6.0) Ø 0.0 (Ø0.6) Ø.70 (Ø9.8) 0.6 (5.9) 0. (.) Ø78.00 (98.) I.57 (0.0) Ø.6 (7.0) 90.5 (80.0) 0 Ø7.0 (8.0).78 (50.0).6 (60.0).9 (7.8) 0.0 (Ø0.).87 (7.9) Switching Devices PG008000E September 0 7
6 .0 R9 Series (UL 98) Fusible 0 800A Contents Page Product Overview Features, Benefits, and Functions Standards and Certifications Illustrations Product Selection Accessories Technical Data and Specifications Dimensions Product Overview R9 Series (UL 98 listed) Fusible 0 800A manual operated multi-pole fusible disconnect switches use double break contacts per pole that ensure complete isolation of the fuse when the switch is in the OFF position. When installed with fuses, they provide protection for low voltage electrical installations against short circuit and overload. Features, Benefits and Functions Load break functionality Double break contacts Up to 00 ka short-circuit rating with Class CC, J or L fuses Compact footprints The optional TEST position function (up to 00A) enables testing of the control circuit auxiliaries without switching the main contacts. This function provides a simple alternative to a separately wired pushbutton Defeatable pistol handles automatically re-latch when the panel door is closed Front or side operation Flange operation NFPA 79 compliant kits Two-, three- and fourpole devices Standards and Certifications UL 98, File E859 for 0 to 800A ratings UL 89, File E05 for H-Frame switches CSA. No., File 776 CSA. No. 5, File 776, H-Frame only IEC 6097-, EN IEC 6097-, EN CE mark NFPA 79 8 Switching Devices PG008000E September 0
7 .0 R9 Series (UL 98) Fusible 0 800A Illustrations R9 Fusible 0A/CC and 0A/J H-Frame Direct and External Operation External front handles Direct handle Shaft extensions for external handles Configurable U Type ACs, for pre-break and signaling or TEST R9 Fusible 0A/J 800A/L (I N-Frames) Direct and External Operation 6 5 External front handle External right side handle (not applicable for N-Frame 600/800A) Direct handle Shaft extensions for external handles 5 Configurable U Type ACs, for pre-break and signaling or TEST 6 Side auxiliary contacts 7 Terminal shrouds 7 Switching Devices PG008000E September 0 9
8 .0 R9 Series (UL 98) Fusible 0 800A Product Selection Direct Operation Front and Right Side Operation (Frame) (Fuse Class) 0 Compact (H-Frame) (CC) 0 (H-Frame) (CC) 0 Compact (H-Frame) (J) 0 (H-Frame) (J) 0 (I-Frame) (CC) 0 (J-Frame) (J) 60 (J-Frame) (J) of Poles Note 00 ka short-circuit rating. Switch Body Only Direct Handle External Selector Handle (Choose one) RH00FCC DHR9HC Black,R, SHB0NHV Shaft Extension for Selector Handle Only (Choose one) + switched neutral RH00FCCSN ) SF0SH5X5H,R, RH00FJ DHR9HJ SHR0NHV 5.70 (00.0) SF00SH5X5H + switched neutral RH00FJSN Black,X SHB0NXHV,X SHR0NXHV R9I00FCC DHR9JM R9I00FCC 7.90 (00.0) SF00SH5X5H External Front Pistol Handle Black,R, PHBNF,R, PHRNF Black,X PHBNXF,X PHRNXF R9J00FJ Black,X Black R9J00FJ (w/ TEST Position) PHBNXFT R9J00FJ R9J060FJ,X R9J060FJ (w/ TEST Position) PHRNXFT R9J060FJ External Operation Switch body + Direct handle Switch body + Shaft + External handle External Right Side Pistol Handle, X PHBNXS, X PHRNXS 0 Switching Devices PG008000E September 0
9 .0 R9 Series (UL 98) Fusible 0 800A Front and Right Side Operation, continued Shaft Extensions for Pistol Handle Only In (mm) NFPA79 (Choose one) Kit 7.90 (00.0) SF00PH5X5.60 (0.0) SF0PH5X (00.0) SF00PH5X (00.0) SF00PH0X0.60 (0.0) SF0PH0X (00.0) SF00PH0X (500.0) SF500PH0X0 NFPA79H NFPA79JKL Auxiliary Contacts (Choose one) AC NO ACNOR9 AC NC ACNCR S Type Auxiliary Contacts (Choose one) Terminal Shrouds Integral to switch AC ACNONCJN AC ACNONCJN AC w/ TEST ACNONCJNT AC w/ TEST ACNONCJNT Switching Devices PG008000E September 0
10 .0 R9 Series (UL 98) Fusible 0 800A Front and Right Side Operation, continued (Frame) (Fuse Class) 60 (K-Frame) (J) 00 (K-Frame) (J) 00 (L-Frame) (J) 00 (M-Frame) (J) 600 (N-Frame) (J) 800 (N-Frame) (L) Notes 00 ka short-circuit rating. Requires test handle. of Poles Switch Body Only Direct Handle (Black) External Front Pistol Handle (Choose one) R9K060FJ R9K060FJ R9K060FJ DHR9JM Black,R, PHBNF R9K00FJ R9K00FJ R9K00FJ,R, PHRNF Black R9L00FJ,X PHBNXF R9L00FJ R9L00FJ R9M00FJ R9M00FJ,X PHRNXF Black,X (w/ TEST Position) PHBNXFT,X (w/ TEST Position) PHRNXFT R9N600FJ DHR9N Black R9N600FJ, X PHBNXF R9N600FJ R9N800FL,X R9N800FL PHRNXF R9N800FL External Right Side Pistol Handle (Choose one) Black, X PHBNXS, X PHRNXS Switching Devices PG008000E September 0
11 .0 R9 Series (UL 98) Fusible 0 800A Front and Right Side Operation, continued (Frame) (Fuse Class) 60 (K-Frame) (J) 00 (K-Frame) (J) 00 (L-Frame) (J) 00 (M-Frame) (J) 600 (N-Frame) (J) 800 (N-Frame) (L) of Poles Notes 00 ka short-circuit rating. Requires test handle. Switch Body Only Shaft Extensions for External Handle In (mm) (Choose one) NFPA79 Kit Auxiliary Contacts (Choose one) Auxiliary Contacts (Choose one) Terminal Shrouds R9K060FJ 7.90 (00.0) NFPA79JKL AC AC Integral to switch R9K060FJ Pistol NO SF00PH0X0 ACNOR9 ACNONCJN R9K060FJ R9K00FJ.60 (0.0) AC AC Pistol NC R9K00FJ R9K00FJ SF0PH0X (00.0) ACNCR9 ACNONCJN AC R9L00FJ R9L00FJ R9L00FJ ACNONCJNT 9.70 (500.0) Pistol AC Pistol SF00PH0X0 w/ TEST TSR9L TSR9L TSR9L R9M00FJ R9M00FJ SF500PH0X0 w/ TEST ACNONCJNT TSR9M TSR9M R9N600FJ 7.90 (00.0) NFPA79N AC TSR9N R9N600FJ Pistol SF00PHX ACNONCJN TSR9N R9N600FJ TSR9N R9N800FL.60 (0.0) AC Pistol TSR9N R9N800FL SF0PHX ACNONCJN TSR9N R9N800FL 5.70 (00.0) TSR9N Pistol SF00PHX 9.70 (500.0) Pistol SF500PHX Switching Devices PG008000E September 0
12 .0 R9 Series (UL 98) Fusible 0 800A Accessories NFPA 79 Compliant Mechanism for Flange Handle Flange Handle for Flange-Operated Switches Cable Operator Rod Operator NFPA 79 Through the Door Kit (Frame) Note Defeatable. (Frame) Handle Type NEMA Type Catalog For side-operated switches only (J-, K-, L-, M-Frame) Standard handle,, R,, FHS Provides heavy-duty flange style 0 00 (J-, K-, L-, M-Frame) operation. Meets both UL 508A and Chrome-plated handle,, R,, X, FHCP NFPA 79 requirements. Please order cable or rod link between handle and switch. Link between Flange handle and side-operated switches. Please order mechanism and Flange handle. Link between Flange handle and side-operated switches. Mechanism included. Please order Flange handle. For front-operated switches only. Meets both UL 508A and NFPA 79 requirements. Kit includes mechanism, shaft and internal handle. Please also order a PH type external pistol handle. (Frame) NEMA Type 0 00 (J-, K-, L-, M-Frame) Mechanism for Flange handle (Frame) For Enclosure Depth In (mm) Cable Length In (mm) CFM 6.00 (9.) CFC (5.0) CFC (08.0) CFC (J-, K-, L-, M-Frame) ( ) RFM Catalog Catalog Catalog 0 (H-Frame) NFPA79H 0 00 (J-, K-, L-, M-Frame) NFPA79JKL (N-Frame) NFPA79N Switching Devices PG008000E September 0
13 .0 R9 Series (UL 98) Fusible 0 800A SO Type Handle PH Type Handle PH Type Handle PH Type Handle Direct Handles Door Interlocked External Front Handles (Frame) Handle Type NEMA Type Color Right Side External Handles (Frame) Handle Type NEMA Type Color Note Includes TEST position. (Frame) Fuse Catalog Front operation. Black. 0 (H-Frame) CC DHR9HC 0 (H-Frame) J DHR9HJ The handle locking function of the front external operation handle prevents the user from opening the door of the enclosure when the switch is in the ON position, and when the switch is padlocked in the OFF position (PH, PH and PH type handles only). Opening the door when the switch is in the OFF position is possible by defeating the locking function with the use of a tool (authorized persons only). The locking function is restored when the door is closed back. 0 (I-Frame) CC DHR9JM 0 00 (J-, K-, L-, M-Frame) J DHR9JM (N-Frame) J/L DHR9N Standard Catalog 0 (H-Frame) SO, R, Black SHB0NHV 0 (H-Frame) SO, R, /yellow SHR0NHV 0 (H-Frame) SO, X Black SHB0NXHV 0 (H-Frame) SO, X /yellow SHR0NXHV 0 60 (H-, I-, J-Frame) PH, R, Black PHBNF 0 60 (H-, I-, J-Frame) PH, R, /yellow PHRNF 0 60 (H-, I-, J-Frame) PH, X Black PHBNXF 0 60 (H-, I-, J-Frame) PH, X /yellow PHRNXF 0 60 (H-, I-, J-Frame) PH, X Black PHBNXFT 0 60 (H-, I-, J-Frame) PH, X /yellow PHRNXFT (K-, L-, M-Frame) PH, R, Black PHBNF (K-, L-, M-Frame) PH, R, /yellow PHRNF (K-, L-, M-Frame) PH, X Black PHBNXF (K-, L-, M-Frame) PH, X /yellow PHRNXF (K-, L-, M-Frame) PH, X Black PHBNXFT (K-, L-, M-Frame) PH, X /yellow PHRNXFT (N-Frame) PH, X Black PHBNXF (N-Frame) PH, X /yellow PHRNXF Standard Catalog 0 60 (J-Frame) PH, X Black PHBNXS 0 60 (J-Frame) PH, X /yellow PHRNXS (K-, L-, M-Frame) PH, X Black PHBNXS (K-, L-, M-Frame) PH, X /yellow PHRNXS Switching Devices PG008000E September 0 5
14 .0 R9 Series (UL 98) Fusible 0 800A X Shaft Extensions for External Handles (Frame) Handle Type Handle Types SH and PH, X Minimum Dimensions Dimensions X (Frame) In (mm) Handle Type Shaft Length In (mm) Catalog 0 (H-Frame) SH (00.0) SF00SH5X5H 0 (H-Frame) SH0.60 (0.0) SF0SH5X5H 0 (H-Frame) SH (00.0) SF00SH5X5H 0 (H-Frame) PH 7.90 (00.0) SF00PH5X5 0 (H-Frame) PH.60 (0.0) SF0PH5X5 0 (H-Frame) PH 5.70 (00.0) SF00PH5X (I-, J-, K-, L-, M-Frame) PH 7.90 (00.0) SF00PH0X (I-, J-, K-, L-, M-Frame) PH.60 (0.0) SF0PH0X (I-, J-, K-, L-, M-Frame) PH 5.70 (00.0) SF00PH0X (I-, J-, K-, L-, M-Frame) PH 9.70 (500.0) SF500PH0X (N-Frame) PH 7.90 (00.0) SF00PHX (N-Frame) PH.60 (0.0) SF0PHX (N-Frame) PH 5.70 (00.0) SF00PHX (N-Frame) PH 9.70 (500.0) SF500PHX Shaft Length In (mm) Catalog 0 (H-Frame) ( ) SH (00.0) SF00SH5X5H 0 (H-Frame).0.7 ( ) SH0.60 (0.0) SF0SH5X5H 0 (H-Frame) ( ) SH (00.0) SF00SH5X5H 0 (H-Frame) ( ) PH 7.90 (00.0) SF00PH5X5 0 (H-Frame).0.7 ( ) PH.60 (0.0) SF0PH5X5 0 (H-Frame) ( ) PH 5.70 (00.0) SF00PH5X (I-, J-, K-Frame) ( ) PH, PH 7.90 (00.0) SF00PH0X0 00 (L-Frame) ( ) PH, PH 7.90 (00.0) SF00PH0X0 00 (M-Frame) ( ) PH, PH 7.90 (00.0) SF00PH0X0 0 00A (I-, J-, K-Frame) ( ) PH, PH.60 (0.0) SF0PH0X0 00 (L-Frame) ( ) PH, PH.60 (0.0) SF0PH0X0 00 (M-Frame) ( ) PH, PH.60 (0.0) SF0PH0X (I-, J-, K-Frame) ( ) PH, PH 5.70 (00.0) SF00PH0X0 00 (L-Frame) ( ) PH, PH 5.70 (00.0) SF00PH0X0 00 (M-Frame) ( ) PH, PH 5.70 (00.0) SF00PH0X (I-, J-, K-Frame) ( ) PH, PH 9.70 (500.0) SF500PH0X0 00 (L-Frame) ( ) PH, PH 9.70 (500.0) SF500PH0X0 00 (M-Frame) ( ) PH, PH 9.70 (500.0) SF500PH0X (N-Frame) ( ) PH.60 (0.0) SF0PHX (N-Frame) (70.0.0) PH.60 (0.0) SF0PHX (N-Frame) ( ) PH 5.70 (00.0) SF00PHX (N-Frame) ( ) PH 9.70 (50.00) SF500PHX 6 Switching Devices PG008000E September 0
15 .0 R9 Series (UL 98) Fusible 0 800A Terminal Shrouds Auxiliary Contacts For the R9 Series Fusible 0 800A, indication of the O and I positions by to auxiliary contacts. Electrical principle: Cabling by terminal cage with #6 AWG maximum. High electrical characteristics: A600/D600 Auxiliary Contacts NO or NC (Frame) of ACs Catalog The different functions (pre-break, 0 and indication, NO Auxiliary Contact TEST feature) are easily configurable with pegs (one or two pegs per position). Two superposed (H M-Frame) ACNOR9 auxiliary contacts maximum. NC Auxiliary Contact For 0A/CC (H-Frame), maximum of four ACs. For 0A/J (H-Frame), maximum of two ACs (H M-Frame) ACNCR9 For 0 to 00A/J (I, J and K-Frame), maximum of four ACs. For 00 to 600A/J (L and M-Frame), maximum of eight ACs. Cabling to the control circuit by terminals with a maximum section of x.5 mm. Electrical characteristics: A00 Terminal Shrouds Notes (Frame) of ACs Same-make/same-break auxiliary contacts. Auxiliary contacts without Test cannot be used on I M-Frame switches. Early-break/same-make auxiliary contacts. For replacement only. Both line and load side terminal shrouds are included with 00A switch. Operating Current I e (Amperes) Nominal Current (Amperes) Catalog (N-Frame) 0 ACNONCJN (N-Frame) NO + NC 0 ACNONCJN 0 00 (I M-Frame) (w/ TEST) 0 ACNONCJNT 0 00 (I M-Frame) NO + NC (w/ TEST) 0 ACNONCJNT Characteristics for Pre-Break Auxiliary Contacts Operating Current I e (Amperes) Nominal Current Contact Type Amperes 50 Vac AC- 00 Vac AC- Vdc DC- 8 Vdc DC (Frame) of Poles Catalog Line or load side protection against direct contact 0 00 (H-, I-, J-, K-Frame) // Integral to switch with terminals or the connection parts 00 (L-Frame) TSR9L 00 (L-Frame) TSR9L 00 (L-Frame) TSR9L 00 (M-Frame) TSR9M 00 (M-Frame) TSR9M 00 (M-Frame) TSR9M (N-Frame) TSR9N (N-Frame) TSR9N (N-Frame) TSR9N Switching Devices PG008000E September 0 7
16 . R9 Series (UL 98) DC Rated Disconnects Accessories Direct Handle PH Type Handle Direct Handle Handle Color Catalog Front operation Black DHR9DE Door Interlocked External Handle Front Operation l 0, Three- and Four-Pole Handle Handle Color NEMA Type Catalog PH Type Black, R, PHBNF PH Type /yellow, R, PHRNF PH Type Black, X PHBNXF PH Type /yellow, X PHRNXF Auxiliary Contacts of AC Type Catalog Early-break/same-make and signaling of positions 0 and : to NO/NC auxiliary contacts to low level NO/NC auxiliary contacts Characteristics: NO/NC AC: IP with front and side operation Connection to the control circuit: By 6.5 mm fast-on terminal Electrical Characteristics: 0,000 operations; A00 Terminal Screens of Poles Position Catalog Line or load side protection against Three- and Four-Pole direct contact with terminals or connection parts Top (line) TSR9DT Bottom (load) TSR9DB Top or bottom (line or load) TSR9DTB 00 Top (line) TSR9ET 00 Bottom (load) TSR9EB 00 Top or bottom (line or load) TSR9ETB Note Order two sets for line and load sides. NO/NC Contact for Three and Four Poles AC C Type AC C Type Low Level NO/ NC Contact for Three and Four Poles AC C Type AC C Type ACNONCDE ACNONCDE ACNONCDELL ACNONCDELL Switching Devices PG008000E September 0 9
17 . Enclosed Rotary Disconnects Product Selection Enclosed Rotary Non-Fusible Ampere Rating Maximum Horsepower Ratings NEMA Enclosure Indoor Accessories for Enclosed Rotary Disconnects 67 NEMA Enclosure Dust-Tight/ Rainproof NEMA X Enclosure Corrosion-Resistant, Stainless Steel Notes Short-circuit current ratings are same as those listed in the table on Page 0, for the respective disconnect amperage. For CSA listed switches, add prefix letter C to the front of the catalog number. NEMA Type enclosures (6 80A) can be field modified to meet NEMA Type R rainproof requirements when a factory-provided drain hole is opened. GB suffix = Gray cover, Black handle; GR suffix = Gray cover, handle; YR suffix = Yellow cover, handle. 5 culus only. 6 Ordered and shipped as separate components not integral to enclosed device. 7 Enclosed disconnects can accept one power pole, neutral or up to two auxiliary contacts (one mounted on either side of switch). Contact the Safety Switch Flex Center ( ) for factory-installed accessories or other special modifications. NEMA X Enclosure Corrosion-Resistant, Non-Metallic NEMA X Enclosure Polycarbonate- Non-Metallic Three-Phase AC 08V 0V 80V 600V Catalog Catalog Catalog Catalog Catalog Three-Pole, 600 Vac ER506UG ER506UD ER506UW ER506UX 5 7-/ 7-/ 5 0 ER505UG ER505UD ER505UW ER505UX 0 7-/ 7-/ 5 0 ER500UG ER500UD ER500UW ER500UX ER500UPGB / 7-/ 0 5 ER500UG ER500UD ER500UW ER500UX ER5060UG ER5060UD ER5060UW ER5060UX ER5060UPGB ER5080UG ER5080UD ER5080UW ER5080UX Four-Pole, 600 Vac ER506UG ER506UD ER506UW ER506UX 5 7-/ 7-/ 5 0 ER505UG ER505UD ER505UW ER505UX 0 7-/ 7-/ 0 5 ER500UG ER500UD ER500UW ER500UX 0 7-/ 7-/ 0 5 ER500UG ER500UD ER500UW ER500UX Disconnect Switched Fourth Pole Unswitched Neutral Pole Auxiliary Contacts (Choose one) Terminal Shrouds 6 SPR56 UNMR5A Single-pole 5 SPR55 ACNONC TSR5A 0 SPR50 NC Three-pole 0 SPR50 ACNC TSR5A SPR560 SPR580 UNMR5B Single-pole TSR5B Three-pole TSR5B Switching Devices PG008000E September
8.2 R5 Series (UL 508) Non-Fusible 16 80A. 8.4 MTS Manual Transfer/Double Throw Switches
. Introduction UL/CSA Standards for Disconnect Switches.................... UL Standards for Electrical Machinery......................... Eaton Solutions for UL 50A and NFPA 79...................... R5
More informationR9 Series Non-Fusible A Compact Page 47 Page 49 Page 51. R9 Series. Page 53 Page 58 Page 59 IEC EN
Circuit Protection.3 Open Rotary Disconnects Product Overview Rotary Disconnect Switch Selection Guide Description Product Description Approvals Description Product Description Approvals Note Q4 2010 R5
More informationContents. Volume 5 Motor Control and Protection CA E December
Rotary Disconnects.4 Contents Description Page Product Description............................. 677 Standards and Certifications...................... 677 Product Selection..............................
More informationFUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A
Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches
More informationFUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A
Fuse protection The solution for > Motor load break. > Protection of industrial cabinet. > Electrical distribution. ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches
More informationNon-Fusible Disconnect Switches
UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of
More informationNon-Fusible Disconnect Switches
UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure
More informationSOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES
MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:
More informationIDE Load break switches for machine control Remotely trippable switch from 32 to 160 A
The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct
More informationFUSERBLOC from 30 to 800 A
from 30 to 800 Product presentation FB30DT FB30SO Ferraz Shawmut FUSERBLO disconnect switches are extremely durable, manually operated, fusible disconnect switches. The switches employ double break contacts
More informationComplete UL/CSA Disconnect Switch Kits
Product Selection Complete UL/CSA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA handle, auxiliary contacts, and padlock attachment.
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationSIRCO Load break switches for power distribution from 125 to 5000 A
The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct
More informationUL 98 Fusible Disconnect Switches
UL 98 Fusible Mersen s fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices capable of fully rated load-break and load-make.
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable f padlocks) E-FA Painted Steel Enclosure
More informationThe safest way to switch power on and off in your industrial control panels.
The safest way to switch power on and off in your industrial control panels. Your problem: You need a range of disconnect switches for your industrial control requirements ranging from Service Entrance
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 10V 40V 40V 480V V 1V 0V Ref. Cat. No. Non-d 0 7. 1 0 A 194R-0-NN 60 1 0 40 B 194R-60-NN UL Class
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 1V 240V 240V 480V V 12V V Ref. Non-d 0 2 7. 1 A2 194R-0-NN 60 1 0 40 B2 194R-60-NN UL Class CC
More informationReferences. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb_cat Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle Direct handle acces_147_a_2_cat
More informationManual Motor Control Switches and Disconnects
Manual Motor Control Switches and Disconnects Vario, GS1, GS2, and LK4 9421CT0301R09/12 2013 CONTENTS Description............................................. Page Mini-VARIO and VARIO Manual Motor Control
More informationSwitch rated plugs and receptacles with NEMA 4X protection
DSN Features and Ratings p. 22 DSN20 p. 23 DSN30 p. 25 DSN60 p. 27 Spare parts p. 29 Dimensions p. 31 21 Switch rated plugs and receptacles with NEMA 4X protection DSN Series products are switch and hp
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationJockey Pump Controllers
BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single
More informationReferences. References. Rating (A) Référence
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
Spec-00252 Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories Modular Disconnect Enclosure, Type 12 INDUSTRY STANDARDS UL 508A Listed; Type 12; File No. E61997
More informationMOTOR PROTECTION CIRCUIT BREAKERS
MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm
More informationJockey Pump Controllers
BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationEnclosed Disconnect Switches
Enclosed isconnect witches ICONNECT ITCE Mersen enclosed disconnect switches are designed to meet customer s requirements for compact and durable individual disconnecting means. Both fusible and non-fusible
More informationFree-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects
763.422.2600 SPEC-00250 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS FREE-STAND TYPE 12 DISCONNECTS Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects TWO-DOOR WITH
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
763.422.2600 SPEC-00252 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS TYPE 12 MODULAR FREE-STAND DISCONNECTS AND ACCESSORIES Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand
More informationUS 5,634,357 D 385,7683 Bulletin: A28S4
763.422.2600 Spec-00385 J763.422.2211 Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Heavy Duty s Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Heavy Duty s Stainless Steel
More informationM C. Ex d M-0... control, monitoring and signalling devices
Ex d M-0... control, monitoring and signalling devices M-0 M-0 series control, monitoring and signalling devices are installed as external accessories on Cortem 'Ex d' enclosures used in any industrial
More informationPowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)
PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 0CT00R/0 0 CONTENTS Description..............................................Page Description.............................................
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationFree-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Heavy Duty Disconnects US 5,634,357 D 385,7683 BULLETIN: A28S4
763.422.2600 SPEC-00385 L763.422.2211 DISCONNECT FREE-STAND STAINLESS STEEL PREFERRED-CUTOUT DISCONNECTS STAINLESS STEEL HEAVY DUTY DISCONNECTS Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless
More informationthe Santon FCS-type switch Disconnect Superior Switch Solutions
the Santon FCS-type switch Disconnect Superior Switch Solutions The technical information given in this table applies to 3 and 4 pole fuse combination switches. FRAME SIZE 1 1 2 3 3 4 4a 4b 5 6 6 nominal
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
. Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT
More informationFree-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects US 5,634,357 D 385,7683 BULLETIN: A21S4
763.422.2600 SPEC-00384 J763.422.2211 DISCONNECT FREE-STAND STAINLESS STEEL PREFERRED-CUTOUT DISCONNECTS STAINLESS STEEL TWO-DOOR DISCONNECTS Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless
More informationUS 5,634,357 D 385,7683 Bulletin: A21S4
763.422.2600 Spec-00384 H763.422.2211 Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Two-Door s Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Two-Door s Two-Door Stainless
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
763.422.2600 Spec-00252 L763.422.2211 Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and accessories Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and Accessories Modular Enclosure,
More informationFree-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects
Spec-01054 Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects Free-Stand Disconnect with Quick-Release Continuous Hinge, Type 4 APPLICATION Simple, heavy-duty with easy door removal
More informationSECTION DISCONNECT SWITCHES
SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase
More informationK1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm
Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure
More information1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers
.2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225 A, 8 to 42
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More informationSwitch-disconnectors OTDC and OTDCP Switches for photovoltaic applications
Protection and Connection Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications DC switch-disconnectors
More informationMetering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs
.3 Features and Benefits Saves installation time and cost One part number to order; no need to worry that any part has been left out Pick the meter or meters you need as it is designed to fit various Eaton
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More informationMotor protection circuit breakers
Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationK1D004ACH cam switch - 4-pole A - for Ø 22 mm
Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam
More informationFUSERBLOC LMDC Fuse combination switches FUSERBLOC Live Maintenance DC
Fuse protection The solution for > Live maintenance of speed drives supplied by a common DC bus > Live maintenance of PV inverters connected in parallel on a same circuit fuser-lm_2_a Strong points > Compact
More informationFree-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects
763.422.2600 SPEC-01054 C763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS FREE-STAND TYPE 4 DISCONNECTS FREE-STAND DISCONNECT WITH QUICK-RELEASE CONTINUOUS HINGE, TYPE 4 APPLICATION Simple,
More informationASCO 920 Remote Control (RC) Switches
Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationMagnetically Actuated Safety Interlock Switches
Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,
More informationSWITCH DISCONNECTORS 11
SWITCH DISCONNECTORS 16A to 1600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 850A 1000VDC in DC21B duty
More informationMaximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches
Series 300 Power Transfer Switches Maximum Reliability & Excellent Value With a Series 300 Transfer Switch, you get a product backed by ASCO Power Technologies, the industry leader responsible for virtually
More informationAllen-Bradley Bulletin 100 Contactors
Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS FR FX FK FW 5 6 7 11 1 14 NC NC snap action snap
More informationPerformance. Standards. Technical data
ilos Loadbreak disconnectors for wall mounting ilos H up to ilos up to 5 ilos 4 0 up to Order codes pplications pprovals / Marking ilos H4 ilos H ddon devices Performance Wall mounting Main disconnector,
More informationStandard Product One-Door Enclosures. Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects
Spec-00251 Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 SPECIFICATIONS 11 gauge steel (.121 inch) Seams continuously welded
More informationTransfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description...
.1 Transfer Switch Equipment Product Selection Guide.................................... Product Description....................................... Application Description......................................2
More informationFree-Stand Type 12 Disconnect Enclosures. Heavy-Duty Free-Stand Disconnect Enclosure, Type 12
Spec-00251 FPH FX (763) 422-2600 422-2211 Disconnect Free-Stand Universal-Cutout Disconnect Enclosures Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 Industry Standards UL 508A Listed; Type 12; File
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationFUSERBLOC and high speed fuses (ur) Fuse combination switches protection of power semi-conductors up to 1250 A
fuser_47_a_1_cat The solution for > Protection of inverters and variable speed drives FUSERBLOC 60 to 150 A Strong points > Limitation of short-circuit current Extended range fuser_49_a_1_cat FUSERBLOC
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationQuick Start Guide TS A
Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationJ7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1
Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload
More informationSafety switches with manual mechanical delay and separate actuator
D Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF VF KEYF VF KEYF7 VF KEYF ACTUATORS MECHANICAL DELAY C L L0 Short knob 0 sec. Short knob sec.
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase
More informationK1K015NZ4 cam stepping switch - 2-pole A - screw mounting
Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationControl Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety
SWE Series: 16 and 2 A Switches Increased Safety 16 A Version - Type 1 16 A Version - Type 2 2 A Version Compliance Data: ATEX - IEC: Zone 1 & 2, 21 & 22 ATEX IEC CE Ex de IIC T6 Ex td A21 T8 C IP66 -
More informationEnclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1
KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG 551 Q4 ~
More informationFree-Stand Disconnects and Accessories
763.422.2600 Spec-00067 L763.422.2211 Free-Stand Preferred-Cutout s Free-Stand s and Accessories Free-Stand Preferred-Cutout s Free-Stand s and Accessories Free-Stand Enclosure, Type 1 INDUSTRY STANDARDS
More informationCS7 Industrial Control Relays
CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)
DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery
More informationSafety switches with separate actuator
A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT
More informationMolded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-...
Circuit Breakers, 09/054 Moeller Electric Corporation Auxiliary Contacts for Type Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic N.O. N.C. Standard auxiliary
More informationLarge Frame IEC Contactors
Large Frame IEC Contactors Bulletin 100-E PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 1 Changing Applications for Contactors There are fewer and fewer traditional large motor starting
More informationSeries CA7 Contactors
Series Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor line.
More informationUL 489 Cable-In / Cable-Out Branch Circuit Breaker
Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up
More informationIntroduction Circuit Protection
Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short
More information22mm Non Illuminated Metal Operators
22mm 22mm Non Illuminated Metal Operators Altech Corp. can provide other push button and actuator options. If your requirement calls for a 22 mm operator which is not shown, please do not hesitate to call.
More informationSafety switches with manual mechanical delay and separate actuator
Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS short knob 20 seconds MECHANICAL DELAY C L05 L L20 long
More informationK1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm
Product data sheet Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationSafety switches for hinged doors
C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More information