PRODUCT BULLETIN NEW ACCESSORY RBC-VCK1 VERTICAL CONVERSION KIT. *** Third Party Supply and Fit ***
|
|
- Calvin Leslie Benson
- 5 years ago
- Views:
Transcription
1 PRODUCT BULLETIN NEW ACCESSORY VERTICAL CONVERSION KIT w RAV Standard Ducted SM_6BTP-E(1) w VRF Standard Ducted MMD-AP_6BHP1-E *** Third rty Supply and Fit *** are pleased to confir the availability of a new accessory to convert Standard Ducted RAV and VRF indoor units to vertical ount. The conversion accessory kit is factory fitted by a third party supplier and standard warranty ters are unaffected when processed through TC Liited Line-up Accessory Vertical Conversion Kit Retail Price Standard Ducted indoor unit conversion to vertical ount 455 Specification Height Width Accessory Depth Cooling External Static Pressure - Standard (Upper - Lower) Accessory Depth Cooling - Standard (Upper - Lower) AP0076BHP1-E AP0096BHP1-E AP0126BHP1-E AP0156BHP1-E AP0186BHP1-E AP0246BHP1-E (115 - ) AP0276BHP1-E (115 - ) AP06BHP1-E (115 - ) AP0366BHP1-E AP0486BHP1-E 1 AP0566BHP1-E 1 Height Width External Static Pressure
2 3. Features 4. Modification to existing drain pan. New stainless steel drain pan. Drain pan insulation. Drain pipe connection. Sensors repositioned. Release Date Available to order ex-works, delivery period 3-4 weeks. 5. Conversion Existing drain pan is cut and refitted to insulate and prevent dew point on outer casing. New insulated stainless steel drain pan is fitted to the indoor unit Existing drain pan bung is relocated to the disused condensate pup outlet to prevent air pressure loss through open pipe located on positive pressure side. Sensors are rerouted to prevent condensate water fro tracking into the electrical copartent. The drain pipe outlet size is increased to for easier connection. For further inforation please contact our custoer support tea on , your local representative, your supplier of products or eail any enquiries to: - general.enquiries@toshiba-ac.co
3 EN14825 Capacity Cooling/ Pressure Cooling/ Power Cooling/ RAVRAV h/a h/a RAV 3/h - g/ Aps SM4ATP-E 3.38/ / /A /A RAV DIGITAL INVERTER DUCTED SPECIFICATION SM564ATP-E SM804ATP-E SM1104ATP-E / / / /0 6./ / /B 4/B 3/B /A 3.83/A 4.14/A (115-) (115-) (115-) (115-) SM4ATP-E 46 to -15/24 to /50 64/ ±10 1.4/ /1/50-10 SM564ATP-E /48 63/65 5- ± 1.1/ /1/50- SM804ATP-E /52 65/ ± 1.7/ /1/50- SM1104ATP-E / x 900 x 3 ± 2.8/ /1/50-
4 EN14825 Capacity Cooling/ Pressure Cooling/ Power Cooling/ RAVRAV h/a h/a SM1104AT8P-E 3.18/ / /A /A RAV DIGITAL INVERTER DUCTED SPECIFICATION SM14ATP-E SM14AT8P-E SM03AT-E /1 2.74/1 2.73/ / / / RAV (115-) (115-) (115-) (115-) 3/h - g/ Aps SM1104AT8P-E / x 900 x 3 ± 3.1/ /3/50-10 SM14ATP-E / x 900 x 3 ± 2.8/ /1/50-32 SM14AT8P-E / x 900 x 3 ± 3.1/ /3/50-10 SM03AT-E1 51/53 /70 13 x 900 x 3 99 ± 3.1/ /1/50-32
5 EN14825 Capacity Cooling/ Pressure Cooling/ Power Cooling/ RAVRAV h/a h/a RAV 3/h - g/ Aps SP4ATP-E 3.38/ / /A /A RAV SUPER DIGITAL INVERTER DUCTED SPECIFICATION SP564ATP-E SP804ATP-E SP1104AT-E /1 3.45/2 3.79/4 4.80/0 6.70/ / /B 5.88/A+ 5.65/A /A+ 0/A 3.87/A SP4ATP-E /47 62/64 5- ± 1.0/ / SP564ATP-E /48 63/64 44 ± 1.4/ / SP804ATP-E /49 64/ x 900 x 3 66 ± 2.1/ 2 0/ SP1104AT-E /50 66/67 13 x 900 x 3 93 ± 3.1/ /
6 EN14825 Capacity Cooling/ Pressure Cooling/ Power Cooling/ RAVRAV h/a h/a SP1104AT8-E1 3.79/4 9.70/ /A /A 3906 RAV SUPER DIGITAL INVERTER DUCTED SPECIFICATION SP14AT-E1 SP14AT8-E1 SP04AT8-E / / /3.48 0/0 0/ / RAV /h - g/ Aps SP1104AT8-E1 46 to -15/15 to /50 66/67 13 x 900 x 3 95 ± 3.1/ /3/50-10 SP14AT-E1 43 to -15/15 to - 51/52 /69 13 x 900 x 3 93 ± 3.1/ / SP14AT8-E1 46 to -15/15 to - 51/52 /69 13 x 900 x 3 95 ± 3.1/ /3/50- SP04AT8-E1 46 to -15/15 to - 51/53 /70 13 x 900 x 3 95 ± 3.1/ /3/50-
7 VRF STANDARD DUCTED SPECIFICATION Capacity Code MMD- AP0076BHP1-E HP 0.8 AP0096BHP1-E 1.0 AP0126BHP1-E 1.3 AP0156BHP1-E 1.7 AP0186BHP1-E 2.0 AP0246BHP1-E Capacity / / / / / / Electrical Aps Start Current Aps AP0246BHP1-E MMD- AP0076BHP1-E External Static Pressure Standard Upper - Lower AP0096BHP1-E AP0126BHP1-E AP0156BHP1-E AP0186BHP1-E /8-1/4 Capacity Code Electrical /8-1/4 3/8-1/4 0-2/1/ /1/ /1/ /1/ /1/ /1/50-5 MMD- AP0276BHP1-E HP 3.0 AP06BHP1-E 3.2 AP0366BHP1-E AP0486BHP1-E AP0566BHP1-E Capacity 1 7.3/ / / / / Aps Start Current Aps AP06BHP1-E AP0366BHP1-E AP0486BHP1-E AP0566BHP1-E MMD- AP0276BHP1-E External Static Pressure Standard Upper - Lower Pressure Power /1/ /1/ /1/ /1/ /1/50-5
MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH
MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationMCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH
MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:
More informationMCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH
MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More information1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS PRODUCT SPECIFICATIONS Horizontal Bulletin No. 20667 November 206 Supersedes August 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION CH 35-8 A - 2 F Unit Type CH = Indoor - Horizontal Series Nominal
More information1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS C35 PRODUCT SPECIFICATIONS Upflow - Cased and Uncased Bulletin No. 20666 February 208 Supersedes November 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION Unit Type C = Indoor Coil = Upflow Series
More informationCeiling Concealed Split System C Series
Brochure AP MCC C 07A Ceiling Concealed Split System C Series features: Microprocessor Controlled ith the microprocessor controlling the operation, the MCC model can offer comfortable room conditions according
More information1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS CX35 Upflow - Cased - R-40A PRODUCT SPECIFICATIONS Bulletin No. 0668 November 06 Supersedes September 05.5 to 5 Tons MODEL NUMBER IDENTIFICATION C X 35-36 A - 6 F Unit Type C = Indoor Coil
More informationDatasheet.
Industrial Test & Mixing Equipment Bringing Test Innovation to you Datasheet This product datasheet has been provided by John Godrich & SJ Electronics in Partnership with BINDER www.johngodrich.co.uk www.sjelectronics.co.uk
More informationSelf-Contained package The Clion-Marine Self-Contained package consists of the following items: Self Contained unit, Control box, Display kit
Self Contained DC Speed control - Reverse cycle (cooling and heating) - Stainless steel drainpan - High performance boxblower with 0-10V speed control - Multiple air outlets - Extremely quiet Self-Contained
More informationTechnical HandBook. Version
Technical HandBook 24 Hour Technical Helpline: 0870 843 0333 Fault & DN Code Apps: Android & iphone Web Page toshiba calc.co.uk/fault codes/ Fault Code Text Service: 07624 803 017 technical.enquiries@toshiba-ac.com
More informationTechnical HandBook. Version
Technical HandBook 24 Hour Technical Helpline: 0870 843 0333 Fault & DN Code Apps: Android & iphone Web Page toshiba calc.co.uk/fault codes/ Fault Code Text Service: 07624 803 017 technical.enquiries@toshiba-ac.com
More informationRBC-AMT32E / RBC-AMS41E
Pocket Quick Reference Guide On the TOSHIBA RBC-AMT32E / RBC-AMS41E Remote Controllers Quick Reference Guide To assist service engineers working on Toshiba air conditioning equipment, there is a large
More informationModel KMF 720 Constant climate chambers with expanded temperature / humidity range
Model KMF 720 Constant climate chambers with expanded temperature / humidity range The BINDER KMF ensures absolutely constant test conditions throughout the testing area. A big advantage of this constant
More informationPocket Quick Reference Guide On the TOSHIBA
Pocket Quick Reference Guide On the TOSHIBA RBC-AMS51E / RBC-AMS54E Remote Controller Quick Reference Guide To assist service engineers working on Toshiba air conditioning equipment, there is a large quantity
More informationWO P-NF-L-M-407c Spec Submittal
WO2-2-10000-2P-NF-L-M-407c Spec Submittal General Specifications WO2-2-10000(801304) Width: IN/CM 136.25/346.07 Height: IN/CM 84.5/214.63 Depth: IN/CM 41.7/105.92 Dry weight: LB/KG 4000/1814.37 Operational
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARYG72LHTA ARYG90LHTA OUTDOOR AOYG72LRLA AOYG90LRLA DR_AR012EF_03 2017.04.07 Notices: Product specifications and design are subject to change
More informationTOSHIBA AIR CONDITIONING
Introduction The following specification describes the Toshiba Super Digital Inverter Heat Pump air conditioning system(s) to be installed at the site below: (ADD SITE NAME) The system(s) shall consist
More informationRIVA I 66. Fire size Riva kW. Heat output
RIVA I 66 Not only will this magnificent landscape cassette fire provide you with significant heating capacity but it will also be a stunning focal point in your living room. Although it is possible for
More informationOur slimmest cistern. Sigma concealed cistern 75 mm for floor-standing toilets
Our slimmest cistern for floor-standing toilets Geberit inwall cisterns hit all the right buttons Easy to install, tough and virtually maintenance free 75 mm Geberit has the most extensive product range
More informationTOSHIBA AIR CONDITIONING
Introduction The following specification describes the Toshiba Digital Inverter Heat Pump air conditioning system(s) to be installed at the below site: (ADD SITE NAME) The system(s) shall consist of the
More informationTechnology is nothing without control
46 Technology is nothing without control An innovative and complete range of integrated controls for application in the Toshiba VRF MiNi-SMMS, SMMS, SHRM systems ensures maximum comfort and excellent performance
More informationSlim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL
E5-3I D-AP 4SP2U Slim Ducted type D-AP0074SP2U D-AP0094SP2U D-AP024SP2U D-AP054SP2U D-AP084SP2U Contents. Specifications 2. Dimensions 3. Center of gravity 4. Piping diagram 5. Wiring diagram 6. Electrical
More informationTemperature probes 468 Hans Turck GmbH & Co. KG Tel Fax Edition I/
468 Hans Turck GmbH & Co. KG Tel. +49 208 49 52-0 Fax +49 208 49 52-264 Temperature probe a Temperature probes TP series TP series Highest possible flexibility A temperature probe has to be flexible and
More informationModel KB 400 Cooling incubators with compressor technology
Model KB 400 Cooling incubators with compressor technology The powerful virtuoso in cooling incubators for microorganisms: the KB masters temperature ranges from -5 C to 100 C. The new KB series consumes
More informationModel KB 240 Cooling incubators with compressor technology
Model KB 240 Cooling incubators with compressor technology The powerful virtuoso in cooling incubators for microorganisms: the KB masters temperature ranges from -5 C to 100 C. The new KB series consumes
More informationModel VDL 115 Vacuum drying chambers for flammable solvents
Model VDL 115 Vacuum drying chambers for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber
More informationLevel sensor Stainless steel version Model RLT-1000, for industrial applications
Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring
More informationVRF. Technical Data Book. DVM S Eco 8, 9 HP
VRF Technical Data Book DVM S Eco 8, 9 HP Version Modification Date Remark Ver.1.0 Released DVM S Eco 8,9HP TDB.06.26 Ver.1.1 Max pipe length modified(equivalent length) : 0 -> 130m 15.04.07 Nomenclature
More informationMillenium II +: general characteristics
Millenium II +: general characteristics Starter kit Blind Temperature sensors Special starter kits Bare board Power supply Level detection Local extensions Accessories Standard Expandable Adjacent extensions
More informationModel KT 53 Cooling incubators with thermoelectric cooling
Model KT 53 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the
More informationSINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU
SINGLE Technical Data Book Big Duct for EU (R4A, 0Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU History Version Modification Date Remark Ver 1.0 Release SINGLE Big Duct for EU (R4A, 0Hz, HP)
More informationPressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2
Electronic pressure measurement Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 WIKA data sheet PE 81.53 Applications Test bench construction Water jet
More informationTank Calibration Survey Report Details
Tank Calibration Survey Report Details Eail: info@avccr.co Fax Subission: -855-707-508 Client Inspection Agency Copany Address File Nuber City Custoer Eail State/Prov Phone/Fax - Zip/Postal Code - Inspector
More informationFPS SERIES Super Slim Ceiling Mount Air Handling Units
About Multistack 19, Multistack is well-known in the international air conditioning industry by its invention of modular chiller. Today, Multistack has grown into an international refrigeration & air conditioning
More informationModel KB 400 Cooling incubators with compressor technology
Model KB 400 Cooling incubators with compressor technology BENEFITS Safe and reproducible incubation conditions even at high environmental conditions Disinfection routine at 100 C MAIN FEATURES Model 400
More informationBlue e+ chillers with the principle
Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide
More informationEE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210
Humidity and Temperature Transmitter for Demanding Climate Control The transmitter by E+E Elektronik meets the highest requirements in demanding climate control applications. Besides the accurate measurement
More informationMAKING MODERN LIVING POSSIBLE. Installation Guide. Twin Kit 086L
MAKING MODERN LIVING POSSIBLE Installation Guide 086L70 www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The
More informationKNX T-UP. Temperature Sensor. Technical specifications and installation instructions
EN KNX T-UP Temperature Sensor Technical specifications and installation instructions Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70 56 / 93 97-0
More informationDEPENDABLE BY DESIGN EASE OF USE PERFORMANCE SERVICEABILITY DURABILITY
FOR VENDED LAUNDRY DEPENDABLE BY DESIGN The Maytag Multi-Load Washer is built to provide the performance and durability your business needs. PERFORMANCE Experience optimal wash performance with a consistent
More informationLinx Continuous Ink Jet Printers Parts List
Linx Continuous Ink Jet Printers Parts List Parts Only Edition 11 June 2013 Parts List Using This Parts and Prices List The information in this Parts List is to provide a distributor of Linx products with
More informationPressure sensor For highest pressure applications to 15,000 bar Model HP-2
Pressure Pressure sensor For highest pressure applications to 15,000 bar Model HP-2 WIKA data sheet PE 81.53 for further approvals see page 6 Applications Test bench construction Water jet cutting High-pressure
More informationSlim duct (AMTTTFNLDEH ) Indoor units
Slim duct (AMTTTFNLDEH ) Slim duct. Specifications 1) Technical specifications Model AM22FNLDEH AM28FNLDEH AMFNLDEH AM4FNLDEH AMFNLDEH Power Supply Ø, #, V, Hz 1,2,22-24, 1,2,22-24, 1,2,22-24, 1,2,22-24,
More informationTemperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual
Temperature and humidity regulator H3020 H3021 H3023 H3027 Instruction Manual Table of content 1. GENERAL SAFETY RULES... 3 2. GENERAL DESCRIPTION... 4 3. REGULATOR MOUNTING AND CONNECTION... 4 4. DESCRIPTION
More informationYour Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant
Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,
More informationSection 10 Mk5 and Mk7 Printhead Offset Code Availability
Mk5 and Mk7 Printhead Offset Code Availability Offset codes available to recalibrate printheads for the Linx inks shown below, if necessary. XXXXXXXXXXXX XXXXXXXInkXXX XXXXXXXXXPrint head 1009 1010 1014
More informationSpecification and Design Catalog. Waterside Economizer
Specification and Design Catalog Waterside Economizer Table of Contents Waterside Economizer Applications.................................................... 4 Application Notes..................................................................
More informationVRF. Technical Data Book. Slim duct for America (R410A, 60Hz, HP) Model : AM***FNLDCH***
VRF Technical Data Book Slim duct for America (R41A, 6Hz, HP) Model : AM***FNLDCH*** History Version Modification Date Remark Ver.1. Release Slim duct for America (R41A, 6Hz, HP) 1.11.4 - Ver.1.1 1.12.28
More informationNEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.
NEW product No, NPPDF 6-01E-3 Large digital sensor 31series SEU-31 Easily viewable LCD dual displays. igh level visibility with 3-color display 2-Color indications depending on output. Main display : Pressure
More informationSorensen SG Series - Water Cooled kw V A. Programmable Precision High Power DC Power Supply
Sorensen SG Series - Water Cooled Programmable Precision High Power DC Power Supply High Power Density: up to 15 kw in 3U Wide Voltage Range: 0-40 V and 0-60 V, in increments of 5 kw from 5 to 15 kw Fast
More informationTEC Unit Conditioner Controller
Document No. 540-1026 TEC Unit Conditioner Controller Generic Controller I/O Layout. See Wiring Diagram for application specific details. Control Applications 2040 and 2041 2050 through 2054 Product Description
More informationBLÜCHER Compact. The flexible drains for easy solutions in housing and commercial applications
BLÜCHER Compact The flexible drains for easy solutions in housing and commercial applications K E E P I N G U P T H E F L O W S T A I N L E S S S T E E L D R A I N A G E S Y S T E M S BLÜCHER Compact
More informationTykoflex cold method. A safe, simple and proven cold method TYKOFLEX COLD METHOD
Tykoflex cold method A safe, simple and proven cold method TYKOFLEX COLD METHOD Our new cold compression method Tykoflex cold compression method has bushings for micro cables in the size range of Ø.8-9.5
More informationVARIABLE REFRIGERANT FLOW SYSTEMS HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL
HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL Expanding the possibilities STATE-OF-THE-ART DESIGN TAKES PERFORMANCE TO NEW LEVELS Our re-engineered Outdoor Units boast an extended operating
More informationHTZ. Description. Features. Smart HART Humidity and Temperature Transmitter
March 2018 Description The HTZ Smart HART Transmitter simultaneously measures humidity and temperature in industrial, commercial, manufacturing, and HVAC applications. Based on the humidity and temperature
More informationModel KT 53 Cooling incubators with thermoelectric cooling
Model KT 53 Cooling incubators with thermoelectric cooling BENEFITS Safe and reproducible incubation conditions even at high environmental conditions Disinfection routine at 100 C Energy efficient, environmentally
More informationModel KB 400 Cooling incubators with compressor technology
Model KB 400 Cooling incubators with compressor technology BENEFITS Safe and reproducible incubation conditions even at high environmental conditions Disinfection routine at 100 C MAIN FEATURES Model 400
More informationModel VD 23 Vacuum drying chambers for non-flammable solvents
Model VD 23 Vacuum drying chambers for non-flammable solvents A BINDER vacuum drying oven VD series gently dries materials with homogeneous temperature distribution. The patented expansion shelf technology
More informationPocket Quick. Reference Guide. On the TOSHIBA RBC-AMS51E. Remote Controller
Pocket Quick Reference Guide On the TOSHIBA RBC-AMS51E Remote Controller Quick Reference Guide To assist service engineers working on Toshiba air conditioning equipment, there is a large quantity of data
More informationIL CAN BK-TC-PAC. Extract from the online catalog. Order No.:
Extract from the online catalog IL CAN BK-TC-PAC Order No.: 2718701 CANopen bus coupler, 24 V DC, bus interface 2 x 5-pos. TWIN- COMBICON connector, complete with accessories (connector and labeling field)
More informationGENERAL SPECIFICATIONS FOR SINGLE-SPINDLE SEMI AUTOMATIC DICING MACHINE MODEL: SS20PLUS
20-May.2015 GENERAL SPECIFICATIONS FOR SINGLE-SPINDLE SEMI AUTOMATIC DICING MACHINE MODEL: SS20PLUS Make Approval 新井 '15/06/04 ( 裕 ) TOKYO SEIMITSU CO., LTD. TOKYO, JAPAN - The contents of this manual
More informationStandard Installation Charges
RATE CARD Standard Installation Charges Product (City) (Upcountry) Window AC or Portable AC 00 00 Split AC (Fixed Speed) 00 00 Inverter AC 00 00 Cassette AC / Verticool (Tower) AC or Floor Standing AC
More informationApplication. Types Available. Duct sensor for air quality, temperature and humidity (optional) Datasheet
LK+ CO2+VOC Duct sensor for air quality, temperature and humidity (optional) Datasheet Subject to technical alteration Issue date: 04.04.2018 A002 Application Duct air quality sensor for detection of CO2,
More informationUser's manual. GREE AHU kit. Type: U-Match Version: 1.02
User's manual GREE AHU kit Type: U-Match Version: 1.02 Thank you for choosing AHU com, please read this user's manual carefully before operation and keep it for further reference. If you have lost the
More information09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD
Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,
More information1:1 Model Connection Interface
Air Conditioner Installation Manual 1:1 Model Connection Interface Model name: TCB-PCNT31TLUL Installation Manual Digital Inverter Air Conditioner 1 English Manuel d installation Climatiseur inverseur
More informationTemperature sensors and accessories for heat and cooling measurement points
Temperature sensors and accessories for heat and cooling measurement points Applications Temperature sensors are metrological components for heat or cold measuring points. They are used in pairs and measure
More informationPROLINE ExtERNal ComPONENts. PROLINE tops and Bases
Spec-00428 E763.422.2211 763.422.2600 PROLINE ExtERNal ComPONENts PROLINE Tops and Bases PROLINE ExtERNal ComPONENts PROLINE tops and Bases Solid tops Solid Tops are used to close the top opening on an
More informationS u p p l y a i r h o o d J S I
Supply air hood JSI PAGE Table of Contents Product description & Product code Functioning principle, Parts Dimensions Positioning, Design Service Exhaust air Pressure loss & sound data Supply air 9 Supply
More informationProduct Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres
Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how
More informationTemperature Measurement SITRANS TS300
Siemens AG 018 For food, pharmaceuticals and biotechnology modular design Dimensional drawings Cable gland M1x1.5 for cable Ø 3... 6.5 (0.1... 0.6) Ø 60 (.36) Ø d = N + H 1 Ø 50.5 (1.99) U X H 1 N H Ø
More informationFloat switch For industrial applications Model RLS-1000
Level measurement Float switch For industrial applications Model RLS-000 WIKA data sheet LM 50.0 Applications Level measurement of liquids in machine building Control and monitoring tasks for hydraulic
More information1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings
Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional
More informationMETAL BLOCK THERMOSTATS
list 2018 METAL BLOCK THERMOSTATS Liquidless temperature control LABTHERM list Metalblock-Thermostats 2018 is the basic system from the Liebisch Product Series with fixed heating block. bottom (W) of case
More informationNEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.
NEW product No, NPPDF 6-01E Large digital sensor 31series SEU-31 Easily viewable LCD dual displays. igh level visibility with 3-color display 2-Color indications depending on output. Main display : Pressure
More informationRefrigerated incubators with forced convection
KB series (E3.1) Incubators Refrigerated incubators with forced convection The most versatile incubator for microorganisms: The BINDER KB series controls a temperature range of -5 C to 100 C. With its
More informationSAFETY re-defined. Backwater Protection. The new Staufix FKA/SWA and Pumpfix F series Top-level backwater protection. Quality Safety Success
SAFETY re-defined Backwater Protection The new Staufix FKA/SWA and Pumpfix F series Top-level backwater protection Quality Safety Success Backwater protection: KE System innovations Body with only mm gradient
More informationIndication and Adjustment Product Information VEGADIS 61. Level Switching Pressure
Indication and Adjustment Product Information VEGADIS 61 Level Switching Pressure 2 VEGADIS 61 Contents Contents 1 Product description...4 1.1 Configuration... 4 1.2 Principle of operation... 4 1.3 Adjustment...
More informationFloor Access Covers. The easy way to see what s underneath! For all horizontal access solutions - talk to Bilco!
Floor Access Covers The easy way to see what s underneath! For all horizontal access solutions - talk to Bilco! Bilco Floor Access Covers Bilco floor access covers are designed to provide convenient, direct
More informationVAREC 5000/5010 SERIES FLAME ARRESTERS
VAREC 000/00 SERIES FLAME ARRESTERS Group D end-of-line flame arresters with a unique extensible bank frame designed to stop the propagation of flame from external sources FEATURES 00 SERIES - HORIZONTAL
More informationTRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights
HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated
More informationInsertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )
The flow meter is based on the thermal mass flow measurement and is ideal for measuring the flow of compressed air and gases in pipes from DN50 (2 ) to DN700 (28 ). With the, the consumption of compressed
More informationA NEW GENERATION OF AIR-CONDITIONING SYSTEMS FOR BOATS AND YACHTS TECHNICAL SPECIFICATIONS CLION-MARINE AIR-CONDITIONING
A NEW GENERATION OF AIR-CONDITIONING SYSTEMS FOR BOATS AND YACHTS TECHNICAL SPECIFICATIONS CLION-MARINE AIR-CONDITIONING TECHNICAL SPECIFICATIONS CLION-MARINE AIR-CONDITIONING Index Specifications Chiller
More informationIKON PRO SENSORS FOR DECKING KITS Add extra functionality with our new Ikon Pro sensors Range includes PIR Presence or Photocell Twilight Detectors
NEW PRODUCT IKON PRO SENSORS FOR DECKING KITS Add extra functionality with our new Ikon Pro sensors Range includes PIR Presence or Photocell Twilight Detectors NEW PRODUCT PRICE LIST PAGE 9 Within this
More informationProduct Data HC2, HC3 HOT WATER COIL - CASED MULTIPOISE
HC2, HC3 HOT WATER COIL - CASED MULTIPOISE Fig.1 ModelHC2/HC3 Product Data A07331 The HydroPlust hydronic coil incorporates proven standards for reliable system operation and performance. The HC2 and HC3
More informationTEFC - Three-Phase - C-Face Foot Mount... A-120. TEFC - Three-Phase - C-Face Foot Mount... A-122. TEFC - Three-Phase - C-Face Foot Mount...
HYDRODUTY - STAINLESS STEEL - ENCAPSULATED TEFC - Three-Phase - C-Face Foot Mount... A-120 TEFC Three-Phase C-Face Footless... A-121 PICKERPLUS - WHITE EPOXY - ENCAPSULATED TEFC - Three-Phase - C-Face
More informationEnvironmental simulation chambers MK MKF MKT MKFT
Environmental simulation chambers MK MKF MKT MKFT 2 Environmental simulation chambers from BINDER Perfectly matched to testing standards. Optimally designed for reliability. We were the first to realize
More informationTemposonics. R-Series Profibus. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm
Temposonics Absolute, Non-Contact Position Sensors R-Series Temposonics RP and RH Stroke length 25 7600 mm Advanced Communication offers Multi-Position Measurement Rugged industrial sensor Linear and absolute
More informationTracer Controllers. Tracer MP503 Input/Output Module BAS-PRC009-EN. January 2005
Tracer Controllers Tracer MP503 Input/Output Module January 2005 BAS-PRC009-EN Introduction The Tracer MP503 input/output (I/O) module is a configurable, multi-purpose device used to provide data monitoring
More informationModel KBW 720 Growth chambers with light
Model KBW 720 Growth chambers with light The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural illumination. That allows this growth chamber
More informationVIREO Ceiling with ALX
Square ceiling air diffuser with nozzles for supply air, with plenum box QUICK FACTS Flush design Suitable for VAV-applications Fast and easy installation Sealing ring, standard for spigot Energy efficient
More information323E L/LN Hydraulic Excavator
E L Diensions All diensions are approxiate. 9 8 0 Reach Boo. VA Boo Stick R.9B R.B R.9B R.B Shipping Height without Guard Rail* 0 080 90 00 Shipping Height with Guard Rail 0 0 0 0 Shipping Height with
More informationK1B004TLH cam switch - 1 pole A - screw mounting
Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam
More informationLimit switch attachments
Limit switch attachments Type codes SRBF SRBF CA3 YR90 MW 22A C2M20 Type SRBF Limit switch attachment Design C Sensor box Mechanical interface A3 A4 A5 A6 Mounting adapter, hole pattern 30x80 mm, for drives
More informationRectangular straight silencer
silencer DLD Dimensions b a l Description DLD has a conventional design with dimensions that not exceed the corresponding connection dimensions. The silencer can be manufactured in all standard duct sizes.
More informationInstallation Service. 1.0 Executive Summary. Factory Trained Technician Train Customer Support Staff On Basic Operation Of The Equipment
Installation Service Statement of Work Start-up Service for Cooling Start-up - 1 - Service for Cooling Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0
More informationAir Conditioning Technical Data FVA-A > FVA71AMVEB > FVA100AMVEB > FVA125AMVEB > FVA140AMVEB
Air Conditioning Technical Data FVA-A > FVA71AMVEB > FVA0AMVEB > FVA1AMVEB > FVA1AMVEB Indoor Unit FVA-A TABLE OF CONTENTS FVA-A 1 Features.............................................................
More informationProgrammable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual
T0210 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual Instruction manual for use of T0210 transmitter
More informationModular system for ACO Bath gullies Easyflow
Modular system for ACO page 54 f. Designer gratings Designer gratings Tileable surface Glass covers Page 67 Top section circular + detached thin bed flange Top section square + detached thin bed flange
More informationASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Multi-Speed ECM Based Air Handler ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions... Airflow Data...6 Heat Kit Data... Wiring
More information