CV-945 Stand-Alone Biometric Reader. Installation Instructions
|
|
- Posy Wilkinson
- 5 years ago
- Views:
Transcription
1 CV-945 Stand-Alone Biometric Reader Installation Instructions
2 Contents 1.0 Introduction Mounting Specifications Application Diagram Wiring Recommended Swiping Technique Programming Adding Admin Finger and delete all users Administrator Programming Add Finger Relay Add Finger Relay Add Finger Relay 1 & Delete Finger Delete All Fingers Change Admin Finger Change Installer Finger Administrator Programming Block Diagram Installer Programming Set Relay 1 Time Set Relay 2 Time Buzzer ON/OFF Backlight ON/OFF Installer Programming Block Diagram Pairing - Biometric and Remote Switch/Relay Unit... 11
3 1.0 Introduction CV-945 is a simple one-door standalone biometric system. The reader can store up to 98 finger templates. It has one relay output and one exit button input. If secure installation is needed, the reader can be connected to a remote relay unit in a secured area, which also acts as a request-to-exit push button. Complete setup and programming can be done by scrolling and tapping on the sensor. The sensor incorporates dedicated sensing hardware to facilitate the detection of spoofing attacks based on fake fingers. This data is embedded into the image data stream, and is processed on the processor. The system is capable of detecting and defeating well-known fake finger mechanisms, such as molded gummy fingers. The coating on the surface of the Touch Chip sensor provides protection from scratching and abrasion due to normal contact with fingertips and any incidental contact with fingernails. Recommendations Consult with installer about safety level of the installation. There are devices with relays compatible with this reader that can increase the security of the system if needed. One or two enrolled fingers are enough for one user. Ask the installer before he leaves the site to enroll your finger as administrator. Note The Reader is using physical roughness of the fingerprint to scan the finger. Some of the users may have very flat fingertips, making difficult for the sensor to recognize correctly the fingerprint. In most cases, these are children and older persons. To solve this problem, do the following: 1. Try with different user s fingers to find the best finger. 2. Check with the installer other models of the reader with added card reader or keypad for other type of access. Maintenance No special or periodic maintenance is required. If cleaning is needed, use soft wet cloth and wipe gently the dirt. Do not use chemicals and materials that can scratch the sensor. Warning! Do not touch the sensor with other objects than finger. Do not pour or splash with water or other liquids. When painting or construction work is ongoing in the area around the reader, protect the reader sensor area from possible damages and paint. If reader is to be dismounted or relocated, call authorized installer for the job. Disposal of this product must be handled according to all national laws and regulations. 2.0 Mounting CV-940-MCP 0.2 (5mm) 3 (3 x 1.2 ) 3 (3 x 30mm) 1 (M3 x 0.2 ) 1 (M3 x 6mm) Do not install the device and cabling close to a source of strong electro-magnetic fields like radio-transmitting antennas. Do not place the device near or above heating equipment. If cleaning, do not spray or splash water or other cleaning liquids. Wipe it out with a smooth cloth or towel. Do not let children touch the device without supervision. Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and fingerprints cannot be entered. If the biometric reader is installed and used outdoors, the reader MUST be fitted with the CV-940-MCP metal cover in order to protect the sensor from direct rainfall or snow. The operating temperature of the product is between -4 F to +122 F (-20ºC ºC). If the reader is installed in an environment where the temperature can drop below -4 F (-20ºC) and/or the sensor could only be exposed to direct sunlight, it is strongly recommended to install the reader inside a third party sealed wall mount box fitted with an additional heater if the temperature is below -4 F (-20 C) to keep the sensor level performance. Camden cannot guarantee the functionality of the product if these instructions are not followed. Page 3 of 11
4 3.0 Specifications Fingerprint Capacity: Output: Push Button Input: Door Open Time: Entry Mode: Programming: Installer/Admin Fingers: Image resolution: Backlight ON/OFF: Buzzer ON/OFF: Firmware Upgrade: Current Consumption: Power Supply: Indication: Mounting: IP Factor: Storage/Operating Temperature: Storage/Operating Humidity: Dimensions: 98 templates 1 x Relay (1 A /24V AC/DC) Yes Pulse (1, 3, 5, 10, 20, 30, 60 seconds) or Toggle(ON/OFF) Finger By scrolling and tapping on the sensor or by keypad 1 Installer + 1 Admin Finger Up to 508 DPI Yes Yes Via RS485 converter and windows application 100 ma max V DC Tricolor Status LED and 4 x Programming LEDs Surface IP65-4 F to +122 F (-20 C to +50 C) 5% to 93% RH without condensation 3 5/8 H x 2 W x 1 D (92mm x 51mm x 25mm) 3 5/8 (92mm) 2 (51mm) 1 (25mm) 4.0 Application Diagram RS ft. (max. 50m) CV-945HS (Optional) 1 Relay Remote Unit and Request-to-Exit Button Secured Area Outside CV-945 Stand-Alone Biometric Reader Page 4 of 11
5 5.0 Wiring Red Black Pink Violet Blue Green Orange Gray Yellow White 12V DC GND A RS485 B Tamp PB NC COM NO Colour Red Black Green Blue Orange Pink Violet Grey Yellow White Connection 12V DC GND Tamper Tamper Push Button A (RS485) B (RS485) NC COM NO Relay (1A) Red Black Pink Violet Blue Green Orange Gray Yellow White + _ PB NC COM GND (PB) + _ 12VDC POWER SUPPLY 1N4001 Diode _ + Electro Magnetic Lock Page 5 of 11
6 6.0 Recommended Swiping Technique Starting from the first finger joint, place the selected finger on the swipe sensor and move it evenly downward in one steady movement. Result: For a valid swipe: Tricolour Status LED turns green + OK Beep (short + long beep) For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep (3 s) 7.0 Programming 7.1 Adding Admin Finger and delete all users 1.Push dip switch no.2 to position ON. 2.Reset the Power of the device. 3. for One long + multiple s 4.Put the dip switch in position OFF. (s will stop) 5. for the LED to blink Orange. 6.Swipe the Master finger min.6 times. (Until Ok Beep) ON 1 2 ON 1 2 x 6 No.2 No.2 Note: This procedure also deletes all the users and administrators previously enrolled. 8.0 Administrator Programming Use point fingers as Administrator and Installer. You can use the other fingers as access fingers. Administrator finger is enrolled at the end of the system installation. Initial enrollment of the Admin finger is described in installer manual. 8.1 ADD Finger Relay 1 (Finger that will activate relay 1) Swipe Admin Finger 1 time x 1 slow blinking Swipe User Finger min. 6 times (until short + long beep) x 6 fast blinking short + long beep Page 6 of 11
7 8.2 ADD Finger Relay 2 (Finger that will activate relay 2) Swipe Admin Finger 2 times x 2 slow blinking Swipe User Finger min. 6 times (until short + long beep) x 6 fast blinking short + long beep Relay 2 is available if the reader is used with remote relay unit with 2 relays(dinrtt and RU2). Consult the installer if Relay 2 is available in your system. 8.3 ADD Finger Relay 1 & 2 (Finger that will activate relay 1 & 2) Swipe Admin Finger 3 times x 3 slow blinking Swipe User Finger min. 6 times (until short + long beep) x 6 fast blinking short + long beep Relay 2 is available if the reader is used with remote relay unit with 2 relays(dinrtt and RU2). Consult the installer if Relay 2 is available in your system. 8.4 DELETE Finger Swipe Admin Finger 4 times x 4 slow blinking Swipe User Finger x 1 fast blinking short + long beep Relay 2 is available if the reader is used with remote relay unit with 2 relays(dinrtt and RU2). Consult the installer if Relay 2 is available in your system. Page 7 of 11
8 8.5 DELETE ALL Fingers Swipe Admin Finger 4 times x 4 slow blinking slow blinking Swipe Admin Finger 2 times x 2 fast blinking multiple beeps 8.6 CHANGE ADMIN Finger Swipe Admin Finger 5 times x 5 slow blinking slow blinking Swipe NEW Admin Finger min.6 times x 6 fast blinking 3 s 8.7 CHANGE INSTALLER Finger Swipe Admin Finger 6 times x 6 slow blinking slow blinking Swipe NEW Installer Finger min.6 times x 6 fast blinking 3 s Page 8 of 11
9 9.0 Administrator Programming Block Diagram Swipe the ADMIN Finger 1 to 6 times depending of the desired menu CV-945 Stand-Alone Biometric Reader 1 Swipe 2 Swipes 3 Swipes 4 Swipes 5 Swipes 6 Swipes ADD Finger Relay 1 ADD Finger Relay 2 ADD Finger Relay 1 & 2 DELETE FINGER Relay 1 & 2 Change ADMIN Finger Enroll INSTALLER Finger new finger min. 6 times new finger min. 6 times new finger min. 6 times already enrolled finger 1 time ADMIN finger 2 times to DELETE ALL new ADMIN FINGER min. 6 times new INSTALLER FINGER min. 6 times 10.0 Installer Programming 10.1 Set Relay 1 Time Swipe Installer Finger 1 time x 1 slow blinking Swipe the INSTALLER Finger and start counting seconds Swipe the INSTALLER Finger to stop or wait 30 seconds to put the relay in toggle mode x 1 fast blinking beeps on 1 second x 1 fast blinking short + long beep Page 9 of 11
10 10.2 Set Relay 2 Time Swipe Installer Finger 2 times x 1 slow blinking Swipe the INSTALLER Finger and start counting seconds Swipe the INSTALLER Finger to stop or wait 30 seconds to put the relay in toggle mode x 1 fast blinking beeps on 1 second x 1 fast blinking short + long beep Relay 2 is available if the reader is used with remote relay unit with 2 relays(dinrtt and RU2). Consult the installer if Relay 2 is available in your system BUZZER On/Off Swipe Installer Finger 3 times x 3 slow blinking Swipe INSTALLER Finger x 1 fast blinking short + long beep 10.4 BACKLIGHT On/Off Swipe Installer Finger 4 times x 4 slow blinking Swipe INSTALLER Finger x 1 fast blinking short + long beep Page 10 of 11
11 11.0 Installer Programming Block Diagram Swipe the INSTALLER Finger 1 to 4 times depending of the desired menu 1 Swipe 2 Swipes 3 Swipes 4 Swipes Set RELAY 1 Time Set RELAY 2 Time BUZZER ON/OFF BACKLIGHT ON/OFF Swipe the Installer Finger and start counting seconds Swipe the Installer Finger and start counting seconds Swipe the Installer Finger to put the Buzzer ON/OFF Swipe the Installer Finger to put the Backlight ON/OFF Swipe the Installer Finger to stop or wait 30 seconds to put the relay in toggle ON/OFF mode Swipe the Installer Finger to stop or wait 30 seconds to put the relay in toggle ON/OFF mode 12.0 Pairing - Biometric Reader and Remote Switch/Relay Unit 12.1 Pairing CV-945HS If a more secure installation is required, the reader can be connected to a remote switch/relay unit in a secured area, which also acts as request-to-exit push button. Follow the instructions bellow to pair (couple) the devices. 12 VDC - + Black Red Yellow Black COM GND White NO 1N Put Dipswitch No.1 to position ON. HS beeps continuously and the red LED blinks. 2. Put Dipswitch No.1 to position OFF. Red Pink Violet Brown 12V out Pink A (RS485) Violet B (RS485) ON for Beep + OK Beep (short + short + long beep) After the OK beep, the pairing is done. CV-945 HS Switch Relay Push Buttons Keypads Strikes Magnetic Locks Key Switches Relays & Timers Access Control 5502 Timberlea Blvd., Mississauga, ON Canada L4W 2T7 Toll Free: Page 11 of 11 File: CV-945 Stand-Alone Biometric Reader Installation Instructions.indd R2 Revision: 27/03/2017 Part No.: 40-82B184
B100-SA Standalone Biometric Reader
EN B100-SA Standalone Biometric Reader User Manual v.b1 Contents 1.0 INTRODUCTION 2.0 MOUNTING 3.0 SPECIFICATIONS......... 3 3 3 4.0 APPLICATION DIAGRAM... 4 5.0 WIRING... 4 6.0 RECOMMENDED SWIPING TECHNIQUE...
More informationB100PROX-MF-SA Standalone Biometric Mifare Reader USER S MANUAL. Relay1 time (for Relay 1 in B100PROX-MF-SA,RU2, RTT and DINRTT )
11.9 Set Door Relay Time Relay1 time (for Relay 1 in B100PROX-MF-SA,RU2, RTT and DINRTT ) Relay2 time (for Relay 2 in RU2, DINRTT Remote Relay Unit) B100PROX-MF-SA Standalone Biometric Mifare Reader Swipe
More informationDINB100-SA Standalone Biometric Reader
a Visual Plus Corporation Company EN DINB100-SA Standalone Biometric Reader User Manual v.a1 Contents 1.0 INTRODUCTION... 2.0 MOUNTING AND DISMOUNTING... 3.0 SPECIFICATIONS... 4.0 APPLICATION DIAGRAM 5.0
More informationDINB100-SA Standalone Biometric Reader
EN DINB100-SA Standalone Biometric Reader User Manual v.b2 Contents 1.0 INTRODUCTION... 3 2.0 MOUNTING AND DISMOUNTING... 3 3.0 SPECIFICATIONS... 3 4.0 APPLICATION DIAGRAM... 4 5.0 WIRING... 4 6.0 RECOMMENDED
More informationDINB100-SA-KIT Standalone Biometric Kit
DINB100-SA DINRTT DINB100-SA-KIT Standalone Biometric Kit User Manual v.b3 Contents 1.0 INTRODUCTION... 3 2.0 MOUNTING AND DISMOUNTING... 3 3.0 SPECIFICATIONS... 3 4.0 APPLICATION DIAGRAM... 4 5.0 WIRING...
More informationEX8. User Manual. Ver 1.0
EX8 User Manual Ver 1.0 EX8 manual ver1.0 Power supply important issue! Use separate power supply when ever is possible, one for EX8 and Reader and another for door lock. This way electrical isolation
More informationCM-110SK Standalone Keypad Installation Instructions
CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm
More informationCV-110SPK Standalone Keypad/Prox Access Control Installation Instructions
CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4
More informationBIOC3 V1 USER S MANUAL. Biometric Reader v. b1
BIOC3 V1 EN Biometric Reader USER S MANUAL v. b1 www.xprgroup.com 1 Contents 1. DESCRIPTION 2. SPECIFICATIONS 3. MOUNTING 4. WIRING 5. CONNECTING BIOMETRIC READERS TO EWS CONTROLLER 5.1 CONNECTING BIOMETRIC
More informationCV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions
CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver
More informationB100PROX-EH(AH) Biometric Proximity Reader INSTALLER MANUAL
B100PROX-EH(H) EN Biometric Proximity Reader INSTLLER MNUL 1 CONTENTS 1. DESCRIPTION 2. SPECIFICTIONS 3. MOUNTING 4. WIRING 5. CONNECTING BIOMETRIC REDERS TO EWS CONTROLLER 5.1 CONNECTING BIOMETRIC REDERS
More informationF6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode
-Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add
More informationSL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.
SL2000E Electronic Code Lock Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming MASTER code for arming/disarming
More informationWaterproof. Keypad/Reader/Controller
Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing
More informationSingle Door Standalone Access Control User Manual
Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self
More informationDOLXFD1000B. Waterproof Access Control/Reader
DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to
More informationDINBIOC3 V1 USER S MANUAL. EN Biometric Reader. v.b2
DINBIOC3 V1 EN Biometric Reader USER S MNUL v.b2 1 Contents 1. DESCRIPTION 2. SPECIFICTIONS 3. MOUNTING 4. WIRING 4.1 CONNECTING DINBIOC3 V1 WITH DINMTPX PROXIMITY REDER 4.2 CONNECTING DINBIOC3 V1 WITH
More informationBIOPAD-M Biometric Keypad Reader User s Manual
BIOPD-M Biometric Keypad Reader User s Manual v.a4 EN Contents 1. DESCRIPTION 2. SPECIFICTIONS 3. MOUNTING 4. WIRING 5. CONNECTING BIOMETRIC REDERS TO EWS CONTROLLER 5.1 CONNECTING BIOMETRIC REDERS IN
More informationFingerprint Access Control F1. User Manual
Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.
More informationBIOPAD-M V1. Biometric keypad reader INSTALLER MANUAL. v.b2
BIOPD-M V1 EN Biometric keypad reader INSTLLER MNUL v.b2 1 Contents 1. DESCRIPTION 2. SPECIFICTIONS 3. MOUNTING 4. WIRING 5. CONNECTING BIOMETRIC REDERS TO EWS CONTROLLER 5.1 CONNECTING BIOMETRIC REDERS
More informationQUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control
QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.
More informationW3-H Waterproof Keypad/Reader/Controller
W3-H Waterproof Keypad/Reader/Controller User Manual 1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark
More informationStandalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit
Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad
More informationStandalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm
Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver
More informationContents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection
Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection LAN Connection RS485 Connection Relay Connection Digital
More informationInstruction Manual. Vogue. Security. Technology. Innovation 2013-V01
Instruction Manual DH16A-60DTE Model 60 with plastic keypad, stand alone access control DH16A-60DTQE Model 60 with plastic keypad, networked access control 2013-V01 Security Technology Vogue Innovation
More informationBIOPROX-MF V1 Biometric Mifare Reader
This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with RoHS directive EN50581:2012 BIOPROX-MF V1 Biometric Mifare Reader User s Manual Visual Plus Corporation,
More informationCM-500 SK 500 USER CODES KEYPAD
CM-500 SK 500 USER CODES KEYPAD Wiring diagram PCB front view ST2 1 3 1 3 N/C contact RL1 (magnet) N/O contact RL1 (strike) ST1 3 2 1 ST2 1 3 RL2 RL1 Strike 2 1 E M B 3 5 T C O 12 V V1 PB2 PB1 Input voltage
More informationRD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual
RD-SR2 Proximity Card Reader with Remote Control User Manual INTRODUCTION The RD-SR2 is a compact, weather resistant multi-function card reader that can be used as a standalone programmable access control
More informationQuick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0
Quick Start Guide ProBio & ProFAC + ZKBioSecurity 3.0 CONTENT 1 Safety Precautions...2 On Using Face Recognition Device...3 Device Overview...5 Product Dimensions & Installation...6 Power Connection...7
More informationSafety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate
www.zkaccess.com Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate Power Connection Ethernet Connection
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationINSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control
STALLATION GUIDE.4 Inch TFT Terminal Time Attendance & Access Control Optional accessories Safety Precautions The following precautions are to keep user s safe and prevent any damage. Please read carefully
More informationEL-ST100 KEYPAD CONTROLLER
WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6
More informationRBR-SB-KTZ001 LAR 2. User Manual
RBR-SB-KTZ001 LAR 2 User Manual INTRODUCTION KTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. Read both EM and HID card.
More informationW3-M. Metal waterproof standalone access control/reader. User Manual
W3M Metal waterproof standalone access control/reader User Manual Name Digital Keypad W3M User Manual Screw driver Rubber bungs Selftapping screws Diode 1. Packing List Quantity 1 1 1 4 4 1 Remark 6*27mm,
More informationPartizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating
1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without
More information-DTZ001- Stand-Alone Proximity Access Control. User Manual
-DTZ001- Stand-Alone Proximity Access Control User Manual INTRODUCTION DTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users,
More informationStand-alone Proximity Access Control
Stand-alone Proximity Access Control User Manual INTRODUCTION VIDI-AC-1C is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. It uses
More informationOperation manual For NG BIOSINGLE Version 1.1
Operation manual For NG BIOSINGLE Version 1.1 SMART-I ELECTRONICS SYSTEMS PVT. LTD.(An ISO 9001:2008 certified company) R&D, Training & Customer Support Center: First Floor, Arihant Plaza Phase II, Village-Ovala,
More informationTEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018
TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018 00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. PRODUCT PRODUCT PROFILE TECHNICAL PARAMETERS 03. INSTALLATION PRODUCT
More informationUser Manual. PCKeypad Wireless Keypad
User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option
More informationVIDI-AC-2CS Access Controller/ Reader
VIDI-AC-2CS Access Controller/ Reader User Manual CONTENTS INTRODUCTION 2 INSTALLATION.4 STANDALONE MODE 6 CONTROLLER MODE.11 WIEGAND READER MODE.. 13 ADVANCE APPLICATION..14 1 INTRODUCTION The VIDI-AC-2CS
More informationINSTALLATION GUIDE BioLite Net English Version 2.10 EN BLN V2.10A
www.supremainc.com INSTALLATION GUIDE English Version 2.10 EN 101.00.BLN V2.10A Contents Safety Instructions... 3 Getting Started... 5 Components... 5 Part names and features... 6 Cables and connectors...
More informationFinger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot
Overview Fingerprint & Finger Vein Device Front Left Side: Finger Vein Device Touch screen Card reader Fingerprint reader Finger vein reader Finger vein sensor: During registration, after finger touches
More informationWiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:
Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact
More informationREX F-0-9 Standalone or Access Controller
REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes
More informationVIS-3200 / VIS-3201 User Manual
2.4GHz Indoor Black Wireless Exit Button Receiver Keypad / Reader Access Control 500 Users Range of 50 Feet Delay and On/Off Toggle Mode Battery Operated Standalone No Software 1 VIS-3200 / VIS-3201 User
More informationGV-Card Reader. User s Manual
GV-Card Reader User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. READER-B 2016 GeoVision, Inc. All rights
More informationBiometric finger print entry system.
Biometric finger print entry system. Installation / Operating Instructions. v1.0b ML-E-BIO-KIT (non-bluetooth) ML-E-BTBIO-KIT (Bluetooth Enabled) Table of Contents Introduction.... 3 Installation & Operating
More information_ Access control SISTEMAS DE SEGURIDAD
_ Access control SISTEMAS DE SEGURIDAD SECURITY SYSTEMS Access control 01 Concept 02 Product 03 Characteristics 04 Compatibility 05 New functions 06 New software 07 References, accessories and diagrams
More informationInstallation Guide (ver 1.0)
IP based Fingerprint Access Control Installation Guide (ver 1.0) www.supremainc.com Contents Safety precautions 3 Basics of fingerprint recognition 5 How to place a finger 6 Product Contents 8 Front Side
More informationDG-800 Stand-Alone Proximity Reader Instruction Manual
DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity
More informationRFT1000 reader in RACS 5. User Manual
Roger Access Control System RFT1000 reader in RACS 5 User Manual Firmware version: 1.3 or newer Hardware version: 1.1 Document version: Rev. A 2016 ROGER sp. z o.o. sp.k. All rights reserved. This document
More informationUser Manual. Before using this device, read and follow all instructions for safety
User Manual Before using this device, read and follow all instructions for safety Copyrightc 2014 KJTECH Co., Ltd. All rights reserved. It is provided for informational purposes only in this manual. All
More informationInstallation Instructions
Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line
More informationINSTALLATION GUIDE BioEntry W2 English Version 1.00 EN BEW2 V1.00A
www.supremainc.com INSTALLATION GUIDE English Version 1.00 EN 101.00.BEW2 V1.00A Contents Safety Instructions... 3 Introduction... 5 Components... 5 Name and function of each part... 6 Cables and connectors...
More informationEZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY
EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual_Layout.indd 8//06 5:8:0 System Components Proximity and Reader 0 x Proximity Tags x Hex Key x Plastic wall plug x Countersunk
More informationSection 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions
CM-120TX Wireless Digital Keypads Installation Instructions Package Contents - (1) Keypad and faceplate assembly - (1) Foam gasket (CM-120W only) - (2) #6-32 x 1 S/S Phillips screws - (2) #6-32 x 1 Tamperproof
More informationKeypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual
secure open Keypad CT Art. No.:, (black) Art. No.:, (white) Installation Manual CT_installation_ENGmay Conlan ApS Speditorvej A DK- Aalborg Tel: + Fax: + www.conlan.eu info@conlan.eu Table of contents.
More informationINSTALLATION GUIDE BioEntry Plus English Version 2.11 EN BEP V2.11A
www.supremainc.com INSTALLATION GUIDE English Version 2.11 EN 101.00.BEP V2.11A Contents Safety Instructions... 3 Getting Started... 4 Components... 4 Features... 5 Part names and features... 5 Cables
More informationINSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3
INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: June, 2016 Version: 1.3 2 What s in the Box 2 Screws & Anchors 2 Screwdriver 4 Diode CONTENT Contents What s in the Box...2 Optional accessories...4
More informationInstallation Guide (ver 1.0)
IP based Fingerprint Access Control Installation Guide (ver 1.0) www.supremainc.com Contents Safety precautions 3 Basics of fingerprint recognition 5 How to place a finger 6 Product Contents 8 Front Side
More informationWiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader
Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader www.grantsautomation.com.au grant@grantsautomation.com.au Wiring Diagrams for MAW6 Digital Keypad For Pedestrian
More informationIP based Fingerprint Access Control. Installation Guide.
IP based Fingerprint Access Control Installation Guide EN 101.00.BEP (ver V1.30 1.2) www.supremainc.com Contents Safety precautions 3 Basics of fingerprint recognition 5 How to place a finger 6 Product
More informationINSTALLATION GUIDE BioEntry W English Version 2.10 EN BEW V2.10A
www.supremainc.com INSTALLATION GUIDE English Version 2.10 EN 101.00.BEW V2.10A Contents Safety Instructions... 3 Getting Started... 4 Components... 4 Features... 5 Part names and features... 5 Cables
More informationGV-RK1352 and GV-R1352 Card Reader
GV-RK1352 and GV-R1352 Card Reader The GV-RK1352 and GV-R1352 are card readers designed to recognize identifications cards. GV-RK1352 comes with keypad, allowing it to also recognize PIN codes. Featured
More informationINSTALLATION INSTRUCTIONS Model 930 EntryCheck
SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 930 EntryCheck
More informationBiometric Lock Programming & Operating Instructions. info. code. Biometric Lock Information. Setting The Master Code. Enrolling A Fingerprint
Biometric Lock Programming & Operating Instructions? info Biometric Lock Information code Setting The Master Code fingerprint Enrolling A Fingerprint Backlight Backlight Settings changing battery Changing
More informationEZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY
EZTAG Manual.qxp_Layout 0/0/06 :7 Page EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual.qxp_Layout 0/0/06 :7 Page System Components Proximity and Reader 0 x Proximity Tags x
More informationInstallation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B
Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Introduction This document contains minimum information that is necessary to properly install the device and to perform its
More informationACCESS CONTROL SYSTEM
ACCESS CONTROL SYSTEM System versions Standalone controllers series based on integrated models KZ-400, 500, 600, 700, KZC-300,800, 900 KaDe Lite system based on integrated controllers KZ-1000 KaDe Premium
More informationPR602LCD v1.0 Installer Manual Rev. A
PR602LCD v1.0 Installer Manual Rev. A Introduction This document contents minimum information required for electrical connections and installation of the PR602LCD access controller in Roger Access Control
More informationWiring Guide EP.NMINI. Version 1.02 Last Updated:
Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass
More informationLTK1100 Series Card Reader User Manual
LTK1100 Series Card Reader User Manual User Manual About this Manual This Manual is applicable to Card Reader. The Manual includes instructions for using and managing the product. Pictures, charts, images
More informationGV-AS Controller. Installation Guide
GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.
More informationVANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD
VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start
More informationBC Digital Keypad. User Manual
BC2200 Digital Keypad User Manual Name Digital Keypad BC2200 User manual Screw driver Rubber bungs Self tapping screws Diode 1. Packing List Quantity Remarks 1 1 1 4 Φ6mm 28 mm, used for fixing 4 Φ4mm
More informationM-PROX2 Installation Instructions
M-PROX Installation Instructions Section General Description The M-PROX (CV-60) is a door access control system. It has inputs for HID/AWID proximity readers, Form C relay outputs for connection to electrified
More informationAS Keypad User Manual
AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output
More informationINSTALLATION GUIDE BioStation L2 English Version 1.00 EN BSL2 V1.00A
www.supremainc.com INSTALLATION GUIDE English Version 1.00 EN 101.00.BSL2 V1.00A Contents Safety instructions... 3 Introduction... 5 Components... 5 Name and function of each part... 6 Cables and connectors...
More informationRevision Date: 02 Mar 2018
KAS Bluetooth Locks HOMES AIRBNB OFFICES SHARED SPACE Revision Date: 02 Mar 2018 COPYRIGHT: Information in this document is subject to change without further notice. No part of this document can be reproduced
More informationFingerprint and Card Reader User Manual
Fingerprint and Card Reader User Manual UD01679N User Manual This Manual is applicable to Card Reader. The Manual includes instructions for using and managing the product. Pictures, charts, images and
More informationXpass S2. Installation Guide. Intelligent IP Access Control Reader EN XPS2 V1.11.
Intelligent IP Access Control Reader Installation Guide EN 101.00.XPS2 V1.11 www.supremainc.com Important Safety Information Carefully review the information within the user manual before installing or
More informationComfort, the Intelligent Home System. Comfort Fingerprint Reader Interface FPR01
Comfort, the Intelligent Home System Comfort Fingerprint Reader Interface FPR01 Introduction to the Comfort Fingerprint Reader Interface... 1 Specifications... 2 Equipment... 2 Settings... 2 Connections...
More informationRXTH DUAL ROOM SENSOR / SWITCH
DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE
More information716 Converter. Programmable Data Converter
716 Converter Programmable Data Converter The 716 can perform over 30 different conversions, supporting Rs232, wieigand, magnetic stripe, wieaba, wand emulation, f2f, and others. Flash upgrading allows
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More informationGENERAL QUICK START GUIDE
GENERAL QUICK START GUIDE 2.8InchPalm & Fingerprint Time Attendance & Access Terminal Version: 1.0 Date: May., 2017 Note: The picture and function presented in this manual are only for reference. The following
More informationAC-2000.USER GUIDE. Version Eng Copyright 2000 By Union Community Co., LTD.
AC-2000.USER GUIDE Version Eng-1.00 Copyright 2000 By Union Community Co., LTD. AC-2000 User Guide 2 Version Date Description Firmware Version 1.00 2016-12-06 -Initial Release 10.61.00-000.02
More informationTwo-door Access Controller
Two-door Access Controller Quick Start Guide V1.0.0 Preface Overview This document elaborates on structure, installation, interface and wiring of two-door access controller. Symbol Definition The following
More information7 Digital Photo Frame
7 Digital Photo Frame Instruction manual L7DPF17 12 month manufacturer's warranty -------------------------------------------------------------------------- --------------------------------------------------------------------------
More informationHSY-S209 EM Metal waterproof access control system User Manual
HSY-S209 EM Metal waterproof access control system User Manual Reading carefully before Install and use this manual 1. Product Profile The product is Contact-less inductive card Metal Password Access Controller,
More informationBioPointe. User's Manual
BioPointe User's Manual Getting to know the BioPointe Notices: Information in this document is subject to change without notice. NO WARRANTY OF ANY KIND IS MADE WITH REGARD TO THIS MATERIAL INCLUDING,
More informationM U L TI - SP ORT SCOREBOARD
M U L TI - SP ORT SCOREBOARD FEATURES: 24 hour clock display Count up timer with range to 9 hr. 59 min. 59 sec. Presettable countdown timer with loud beep Large 4 inch LCD digits for viewing from as far
More informationBluetooth Enabled Access Control MODEL BG-FE. Operating Instructions
BlueGuard FE Bluetooth Enabled Access Control MODEL BG-FE Operating Instructions CAUTION AND SAFETY INFORMATION IMPORTANT: If the equipment is used in a manner not specified in this manual, the protection
More informationManual er under oversettelse til norsk.
Manual er under oversettelse til norsk. Suprema Inc. 16F Parkview Office Tower, Jeongja-dong, Bundang-gu, Seongnam, Gyeonggi, 463-863 Korea E-mail : support@supremainc.com Website : www.supremainc.com
More informationSpecifications: Features:
ROFU Features: Applicable card mode EM Card / Key Fob 1 Administrator and 200 Users 200 Proximity Cards / Key fobs Access Modes:Use Bluetooth smartphone or Card / Key fob to access Built-in Tamper alarm
More information4 Wire Video Intercom System
VT596(F)/KP USER MANUAL(EN) 4 Wire Video Intercom System VT596/KP VT596F/KP Read this manual carefully before using the product, and keep it well for future use. -1-1. Parts and Functions Camera Lens Speaker
More informationKP2000E/EM Series Style Keypad
23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact
More information