DSC PowerSeries Neo Integration

Size: px
Start display at page:

Download "DSC PowerSeries Neo Integration"

Transcription

1 DN DSC PowerSeries Neo Integration The purpose of this application note is to explain how to setup the DSC PowerSeries Neo integration with a KT-400 or a KT-1-M (or PCB) using an RS-232 or IP connection. Minimum Requirements: EntraPass Special, Corporate, or Global Edition 6.04 or higher. Kantech Controller: o KT-400 Firmware 1.17 or higher o KT-400 rev1 Firmware 1.23 or higher o KT-1-M or PCB Firmware 1.03 or higher DSC: o Neo alarm Panel Firmware 1.10 Verify Firmware at menu [900]-[000] o TL280R or TL2803GR(E) or 3G2080R(E) Firmware 5.00 Verify Firmware at menu [900]-[460] o Neo HS2LCD Keypad Firmware 1.10 Verify Firmware at menu [900]-[001] Connection 1

2 Neo Configuration: Using the DSC PowerSeries Neo Keypad: 1. Enable the TL280R, TL2803GR(E), 3G2080R(E) settings: a. [*8]-[installer code]-[382], Communicator Option 3, set option {5} ON 2. Enable SMS unicode a. Section [851][301] Option 5 SMS Unicode needs to be ON. 3. Enable communication: a. RS-232: [*8]-[installer code]-[851]-[425] > Ensure only bits 1 and 5 are ON b. IP: [*8]-[installer code]-[851]-[425] > bit 3 and 5 [*8]-[installer code]-[851]-[428] > define the panel IP address UDP: [*8]-[installer code]-[851]-[426] > bit 1, 3, 4 TCP: [*8]-[installer code]-[851]-[426] > bit 3 4. Enter Integration Identification Number in EntraPass a. [*8]-[installer code]-[851]-[422] Capture all 12 hex values and enter in EntraPass (only the first 6 digits will be visible, use the arrow keys to see the remaining digits) 5. Enter Integration Access Code in EntraPass a. [*8]-[installer code]-[851]-[423] Capture all 8 hex values and enter in EntraPass (only the first 4 digits will be visible, use the arrow keys to see the remaining digits) EntraPass Setup: If virtual zone is to be used, please program virtual zone. Address 560, please refer to PowerSeries Neo programming manual. Go to the Devices tab and select the Integrated Panel button a. Click the New button and name the device accordingly b. In the Connection Type drop down list, select DSC PowerSeries Neo connected to controller (Serial or IP) or DSC PowerSeries Neo connected 2

3 to gateway (Serial or IP) c. In the Panel model drop down list, select the Panel model d. Click the Configuration button and enter the master code in the Master code textbox Note: This code will be used for receiving the programming and updating the alarm panel with the new user codes. The default Master code in a DSC intrusion panel is e. In the Controller selection for pass-through select the controller is connected to DSC PowerSeries Neo panel 1. Enter the Integration Identification Number and Integration Access Code gathered in the Neo Configuration section 3

4 f. Under the communication tab, Select if the integration to the communicator will be done via RS-232 / IP-TCP or IP-UDP. For IP, enter the information obtained by the NEO configuration. 1. Using TCP, the IP address of the controller is automatically entered. Within the NEO configuration, will need to enter this IP address. g. Click Ok h. In the Panel Component tab, select the number of zones, partitions and users to be included i. Click Save j. The Configuration Form will reappear. Select the Default Code and click OK. Note: The uploading of the intrusion panel may take 2-3 minutes depending on the programming. During this time, the intrusion panel will be in programming mode. Once the 4

5 intrusion panel uploading is complete, an event called Panel components upload completed will occur in the message list. Programming user codes: To program new user codes or to modify existing ones, go to the Devices tab and select Integrated Component a. Within the Integrated component tab, make sure the View component hierarchy button is pressed b. To better manage the components, click the All Components button and select Users c. Select the Corporate gateway that the intrusion panel is connected to under the Gateway drop down list d. From the Panel drop down list, select the previously created intrusion panel e. From the Component drop down list, select a user, and name the user accordingly f. Click on Configuration g. Enter the user access code that will be used h. Save the configuration Note: there is an icon in the Component type list box. This icon represents the status of the component. 5

6 Note: The EntraPass system can only download information from the intrusion panel while it is disarmed. If the intrusion panel is armed, EntraPass will buffer the modification until the intrusion panel disarms. Arming and disarming via manual operations: To request an arming or disarming of partitions, go to the Operation tab and select Integrated panel a. If shown, on the left pane select the proper intrusion panel b. In the right pane, select the partition you wish to arm or disarm c. Right click on the partition and select a task 6

7 Intrusion on Graphics: To view a virtual keypad or intrusion components from a graphic, go to the Definition tab and select the Graphic button a. Create a new graphic or choose the appropriate graphic from the Graphic drop down list b. Click the Click here to create, edit or modify a graphic button c. Drag and drop the Panel component icon on the graphic screen d. Select the Keypad from the list box Note: You may also add zones and partitions on the graphic. You may arm and disarm partitions by setting default double click functions. e. Close the window by clicking on the at the top f. Save the graphic g. You may view a graphic from the graphic desktop Viewing events and reports: 1. To view intrusion events, go to the Desktop tab and select Desktop 1 Button. a. From the Message list, you can view all the access and intrusion events. b. To view only access or intrusion events, click on the All Events button and select DSC intrusion events 7

8 2. You may generate reports, video trigger, real time notifications and alarm acknowledgments based on intrusion events. You can better search for events by sorting by access control events or intrusion events in the above mentioned windows. Single Partition Management (by partition) via a Reader: To arm a single partition via a reader, go to the Devices tab and click the Door button a. Make the appropriate Gateway, Site and Controller selections, and select the door used for arming/disarming the partition b. Go to the Options and alarm system tab and click the External alarm system options button c. In the Alarm system options window: i. For arming: 1) If you are arming via card and pushing button, choose the appropriate input in the Arming request Input 2) If you are arming via card and keypad button, choose the appropriate button to be used as an arming request in the keypad button drop down list ii. iii. Choose when cardholders will be able to arm the intrusion system by choosing a schedule in the Enable Arming Request schedule textbox Choose which card holder will be able to arm the intrusion system by choosing a single access level, or group of access levels, in the Arming access level textbox iv. Go to the Disarming request tab and choose which card holder will be able to disarm the intrusion system, by choosing a single access level or group of access levels in Postpone or disarm access level textbox 8

9 v. Go to the Partitions tab and under the Partition to arm textbox select the partition associated to this door. vi. Check the Authorize disarming during exit delay if you want to be able to disarm during an exit delay vii. Press Ok and save the door. Note: The default user code programmed earlier in step 2.f is used as the user code for arming and disarming of the partitions. PLEASE NOTE: THERE IS NO VIRTUAL KEYPAD WITH THE NEO INTEGRATION. 9

10 Virtual Zones Programming (Single Panel): DSC PowerSeries Neo allows the assignment of up to 32 of its total zones as virtual zones. A DSC PowerSeries Neo zone can be triggered in Alarm, Trouble, Tamper by Kantech inputs, doors or controller events using Virtual zones. The benefit is that a Kantech Controller Door can cause an event on a DSC PowerSeries Neo zone without any wiring, and transmit the event to the monitoring central station if needed. Note - the following Firmware is required: o KT-400 Firmware 1.17 or higher o KT-400 rev1 Firmware 1.23 or higher o KT-1-M or PCB Firmware 1.03 or higher Note: HS2016 can only have 16 virtual zones The following steps describe the method to program a single panel as a virtual zone: 1. DSC Virtual zones need to be assigned to a DSC physical zone using the DSC keypad using option a. On the keypad: [*8]-[installer Code],[560] b. Scroll the Virtual Zone desired and press * c. Choose the physical zone to be linked: ex: 009 d. Press # when done 2. Go to the Devices tab and select the Integrated Panel button a. Select the previously created DSC PowerSeries Neo panel b. Click the Panel Component tab c. Under Virtual zone select the number of virtual zones you have d. Save the integration module 3. Go to the Devices tab and select the Integrated Component button. a. Select the appropriate Virtual Zone in the Component dropdown list b. Click on Configuration c. Choose the Kantech component type to link in the Component type dropdown list d. Choose the Kantech component in the Component source 10

11 e. Check the proper DSC Component action the Virtual zone will cause on the DSC PowerSeries Neo f. Press Ok g. Save the virtual zone Virtual Zones Programming (Multiple Panels): The following describes the method to program a multiple panels as virtual zones using the virtual zone mapping window: In order to link components from multiple controllers, the gateway will manage or supervise the events of all controllers, other than the one where the Neo panel is used. The virtual zone mapping window will now be populated with all appropriate devices. When opening the mapping of components to a virtual zone, the list of components is based on the devices of the same gateway and same account where the Neo panel is used. For example, doors: the doors will be listed where Neo is connected, along with and doors of all the other controllers using the same gateway. 11

12 The Gateway will monitor the events from the other controllers and send commands to the KT s DLL to update the virtual zone, accordingly. Communication With NEO Panel RS-232 IP / 485 KT-1 KT-1 / KT-400 Neo passthrough IP / 485 Update KT DLL Command to Neo Panel IP State of components are reported to the gateway based on the normal process. Integration DLL at the gateway level process link between EntraPass Controller- Door-Input and, if required, send command to the KT/NEO interface to change the steate of the virtual input on the NEO panel. IP / 485 Slave Controller Gateway IP / 485 KT-300 slave controller IP Server Using this connectivity, where the gateway is sending commands to Neo (through a KT-1 or KT-400), it is possible to interact with all types of controllers on that gateway (KT-100, KT- 200, KT-300), even if connected through RS-485 bus. 12

13 Input Door Events EntraPass Events to DSC Virtual Zones status: Input in Alarm EntraPass EntraPass Events Input in Trouble (only Double EOL) Input tamper in alarm (only Double EOL) Open/Close (Door contact status) Door forced open Door alarm on relock Door pre-alarm open too long DSC PowerSeries Neo REPORT ALARM REPORT TROUBLE Door open too long Door lock device failure Duress Duress Feature (Timed Reset) Controllers Controller AC power failed / Controller AC power restored REPORT TAMPER Controllers Tamper switch in alarm / Tamper switch restored Controller Auxiliary power failure / Controller Auxiliary Controllers power restored Controllers Controller reader power failure / Controller reader power restored Controllers Controller battery power failure / Controller battery power restored Controllers Controller module communication failure /Controller module communication restore Controllers Controller DC power failed / Controller DC power restored Controller lock power failed / Controller lock power Controllers restored Controllers Controller power trouble (KT-1) Door Door forced open / Door forced open Restored Door Door open too long / Door open too long restore Door Door lock device failure / door lock device failure restored Access Denied Access Denied Bad Card Status (Timed Reset) 13

14 The PowerSeries Neo/Kantech integration provides users with the following abilities: Receiving programming of the intrusion system: the partition and zone names can be uploaded to the EntraPass software from the intrusion panel. The partitions and zones can be used for various actions, such as operator operations. Additionally, the user codes can be uploaded from the intrusion panel and stored in the EntraPass software. The EntraPass operator can program and download new user codes to the intrusion panel or modify existing ones. Receiving events from the intrusion panel: the intrusion panel events can be viewed on the message list, and be used for reporting in conjunction with the standard access events. Furthermore, these intrusion events can be used to trigger video recordings, pop-up alarms, notifications and other actions. Manual operations from EntraPass: the operator can perform manual operations on partitions from the EntraPass software, operations such as: Partition arm away, partition arm stay, partition arm no entry delay, partition arm with code, and disarm partition with code. Using intrusion components on graphics: the uploaded zones and partitions can be used in graphic floor plans to visualize where each zone, partitions and traditional access control components, are located on the floor plan. The operator can view the status of each of the components and perform operations on partitions. Arm and disarm partitions: the intrusion panel partition can be linked to a reader or readers to request an arming and disarming of the partition via a card. When a card holder presents a card and pushes the appropriate button on the reader, the KT- 400/KT-1 will send an arming request to the intrusion panel. When a card holder presents a card and opens the doors, the KT controller will send a disarming request to the intrusion panel. The EntraPass software supports single partition management per reader or multiple partition management per reader. There is no support for Virtual Keypad at this point with this integration. 14

DSC POWERSERIES NEO INTEGRATION. This application note will explain how to setup the DSC PowerSeries NEO integration on a KT-400 or a KT-1-M

DSC POWERSERIES NEO INTEGRATION. This application note will explain how to setup the DSC PowerSeries NEO integration on a KT-400 or a KT-1-M DN NUMBER HERE DSC POWERSERIES NEO INTEGRATION This application note will explain how to setup the DSC PowerSeries NEO integration on a KT-400 or a KT-1-M Minimum Requirements: EntraPass Special, Corporate,

More information

DSC MAXSYS INTEGRATION THROUGH A KT-400 CONTROLLER

DSC MAXSYS INTEGRATION THROUGH A KT-400 CONTROLLER DN NUMBER HERE DSC MAXSYS INTEGRATION THROUGH A KT-400 CONTROLLER The purpose of this application note is to configure the EntraPass system to integrate with the DSC Maxsys tm intrusion panel. Starting

More information

Release Notes. DN / Version 4.03

Release Notes. DN / Version 4.03 Release Notes DN1525-1003 / Version 4.03 Copyright 2010 Tyco International Ltd. and its Respective Companies. All Rights Reserved. All specifications were current as of publication date and are subject

More information

exacqvision DSC PowerSeries Neo integration

exacqvision DSC PowerSeries Neo integration Overview exacqvision can be integrated with DSC PowerSeries Neo intrusion systems. Configuration controls and realtime feedback have been added into the exacqvision client giving the user control and monitoring

More information

Connect Alarm app App operation quick guide

Connect Alarm app App operation quick guide SECURITY PRODUCTS If you can read this Click on the icon to choose a picture or Reset the slide. To Reset: Right click on the slide thumbnail and select reset slide or choose the Reset button on the Home

More information

Exacq Mobile. User Manual 9.2. (Updated March 9, 2018)

Exacq Mobile. User Manual 9.2. (Updated March 9, 2018) Exacq Mobile User Manual 9.2 (Updated March 9, 2018) www.exacq.com March 9, 2018 Contents ii Contents Introduction... 4 Installation...4 Web services... 4 Adding a web service...4 Activating and deactivating

More information

Developer s Guide. PC54O1 Serial Interface Module Version 1.0

Developer s Guide. PC54O1 Serial Interface Module Version 1.0 Developer s Guide PC54O1 Serial Interface Module Version 1.0 IMPORTANT This manual contains information on limitations regarding product use and function and information on the limitations as to liability

More information

Exacq Mobile. User Manual. September 2018 Version 9.6

Exacq Mobile. User Manual.   September 2018 Version 9.6 Exacq Mobile User Manual www.exacq.com September 2018 Version 9.6 Contents Introduction... 5 Installation...5 Web services...5 Adding a web service...6 Activating and deactivating a web service...6 Logging

More information

Pro-Watch 3.8 Eco System Galaxy Dimension Integration Guide

Pro-Watch 3.8 Eco System Galaxy Dimension Integration Guide Pro-Watch 3.8 Eco System Galaxy Dimension Integration Guide Document Date : Aug 2010 Pro-Watch 3.8 Galaxy Integration Guide.doc Page 1 of 15 Table of Contends Chapter Page Scope of this document 3 Installation

More information

exacqvision Kantech - Client Integration Guide

exacqvision Kantech - Client Integration Guide Overview ExacqVision can control and view status of Kantech access control equipment, such as KT-1 or KT400 hardware, via Entrapass Web. Operational controls and realtime feedback capability have been

More information

Telephone and Reporting Setup in ElkRP

Telephone and Reporting Setup in ElkRP Telephone and Reporting Setup in ElkRP 1. To add a telephone, right click on Telephones under Folder items on the left side of the screen. Then select New Telephone. 2. On the New Telephone IDs screen,

More information

New Product Announcement

New Product Announcement New Product Announcement EntraPass v7.30 Software Tyco Security Products is pleased to announce version 7.30 of Kantech s flagship EntraPass security management system software. We continue to build upon

More information

High Security and Access System EVO48 V2.1 EVO192 V2.1

High Security and Access System EVO48 V2.1 EVO192 V2.1 High Security and Access System EVO48 V2.1 EVO192 V2.1 Programming Guide Includes LCD Keypad Programming We hope this product performs to your complete satisfaction. Should you have any questions or comments,

More information

Honeywell Total Connect enables notifications and control via the Web, , or Phone from a Remote Location

Honeywell Total Connect enables notifications and control via the Web,  , or Phone from a Remote Location Total Connect User Guide GSM Network GPRS data SMS data AlarmNet Central Station Protected Premises with 7845GSMR/i-GSM AlarmNet Radio Internet Control Panel Honeywell Total Connect enables notifications

More information

MG/SP Series (V4.9/V5.1) What s New

MG/SP Series (V4.9/V5.1) What s New MG/SP Series (V4.9/V5.1) What s New Firmware: SP4000 and SP5 version 5.1 SP5500, SP000, SP7000, and MG5050 version 4.9 (SP5500 pictured) Overview: New Programming Sections New Events New Trouble Display

More information

M2M Services. M2M Smartphone Application Overview v.2.0

M2M Services. M2M Smartphone Application Overview v.2.0 M2M Services M2M Smartphone Application Overview v.2.0 First steps with the RControl app and login instructions Depending on your phone you can get the application from Apple App Store, Android PlayStore

More information

Configuring Door and Device Templates

Configuring Door and Device Templates CHAPTER 8 This chapter describes how to create and modify door and device templates. Device templates define common settings for device types, such as Gateways, readers and locks. Door templates define

More information

Understanding Door Configuration

Understanding Door Configuration CHAPTER 5 This chapter describes the concepts used to configure doors and templates. A door configuration is a collection of devices, such as locks and readers, connected to a Cisco Physical Access Gateway

More information

Avantis AXI WEB SERVER MODULE USER MANUAL

Avantis AXI WEB SERVER MODULE USER MANUAL Avantis AXI WEB SERVER MODULE USER MANUAL CONTENTS CHAPTER 1: SYSTEM LOGIN AND WEB PAGE LAYOUT 1.0 ACCESSING THE WEB PAGE 1.1 USER AUTHORITY 1.1.1 MASTER USER 1.1.2 USER/ GUEST SETTING 1.1.3 INSTALLER

More information

TCS Access Control System Cheat Sheet

TCS Access Control System Cheat Sheet TCS Access Control System Cheat Sheet Access Control Main Screen 1 Toolbar 2 Device View Toolbar No. Name Function 1 Login Logs in the ASServer. 2 Logout Logs out the ASServer. 3 Devices Defines controllers

More information

INT-TSI Brief User Manual

INT-TSI Brief User Manual int-tsi_u_en 03/15 Keypad INT-TSI Brief User Manual SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. 58 320 94 00 info@satel.pl www.satel.eu Firmware version 1.04 WARNINGS Please read this

More information

2015/09/24. M-Touch

2015/09/24. M-Touch M-Touch 2.00.12 VERSION HISTORY (> 1.00) Graphics Maps: by means of Graphic Maps it s possible to display the alarm zones simply by tapping icons on the map shown on keypad screen. It s very simple to

More information

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel:

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel: FSK TX CELLULAR PLUS Installation and Programming Guide Tel: 0861 105 962 www.fsk.co.za INTRODUCTION The FSK TX Cellular Plus (TXC+) is a highly featured GSM based unit which is used for the transmission

More information

SOFTWARE VERSION 3.20

SOFTWARE VERSION 3.20 48EPEP-00 SOFTWARE VERSION 3.20 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]

More information

Digiplex EVO High Security and Access System What s New EVO192 V2.7

Digiplex EVO High Security and Access System What s New EVO192 V2.7 Digiplex EVO High Security and Access System What s New EVO192 V2.7 Overview New zone programming and additional zone/system/anti-mask options EN 50131 compliancy Now supports automatic label broadcast

More information

Release Notes Access Control and Security Management Software

Release Notes Access Control and Security Management Software Access Control and Security Management Software DN1553-1105 / 5.00 Version Copyright 2011 Tyco International Ltd. and its Respective Companies. All Rights Reserved. All specifications were current as of

More information

5.5 AS Layout. GeoVision Technical Handbook 77

5.5 AS Layout. GeoVision Technical Handbook 77 5.5 AS400 5.5.1 Layout GeoVision Technical Handbook 77 5.5.2 Wiegand Reader Connection AS400 supports up to eight Wiegand 26 ~ 64bit readers Wiegand connection has a distance limitation of 30m (~ 100ft)

More information

Keypad LCD (software version 3.10) CA-10 plus

Keypad LCD (software version 3.10) CA-10 plus PROGRAMMING AND INSTALLATION MANUAL Keypad LCD (software version 3.10) CA-10 plus GDAŃSK ca10plci_e 09/03 WARNING Due to safety reasons, alarm system should be installed by qualified personnel only. Because

More information

NOTE: This integration applies only to the Bentel Access Control Panel/Keypad equipment with firmware version 3.50 or later.

NOTE: This integration applies only to the Bentel Access Control Panel/Keypad equipment with firmware version 3.50 or later. This integration guide applies to the Absoluta series of access control panels from Bentel Security. (Test reference: model ABS104 control panel and M-Touch keypad) Overview exacqvision can be integrated

More information

SOFTWARE VERSION 3.10

SOFTWARE VERSION 3.10 728PEP-03 SOFTWARE VERSION 3.10 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]

More information

Total Connect 2.0 Online Help

Total Connect 2.0 Online Help Security Events Users Locations Video Hints for use. After logging in hit F11 to toggle full screen mode. Hover over icons for tool tip help. Upon the initial login, control panel data should be imported

More information

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

IDS.  Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2. INHEP DIGITAL IDS S E C U R I T Y Users Guide to Keypad Functions MANUAL NO. 700-146-01D ISSUED NOVEMBER 2002 VERSION 2.17 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm

More information

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL

More information

pro ACTpro IOM INPUT/OUTPUT MODULE Installation and Configuration Instructions for the ACTpro IOM Input/Output Module ACT Product Code: ACTPRO IOM

pro ACTpro IOM INPUT/OUTPUT MODULE Installation and Configuration Instructions for the ACTpro IOM Input/Output Module ACT Product Code: ACTPRO IOM pro ACTpro IOM INPUT/OUTPUT MODULE Installation and Configuration Instructions for the ACTpro IOM Input/Output Module ACT Product Code: ACTPRO IOM pro CONTENTS Technical Specification... 4 Product Overview...

More information

Important Notice. Customer Information. 2 WisDom User Manual

Important Notice. Customer Information. 2 WisDom User Manual User Manual Important Notice This manual is delivered subject to the following conditions and restrictions: This manual contains proprietary information belonging to RISCO Group. The information is supplied

More information

XR500/XR100 Command Processor Review. a) Zone expanders c) Output expanders b) All of these d) Single point detectors

XR500/XR100 Command Processor Review. a) Zone expanders c) Output expanders b) All of these d) Single point detectors Name Answer Key Company Address City, State, Zip Instructor Date Your email User Name = Password = XR500/XR100 Command Processor Review 1. may be connected to the LX-Bus. a) Zone expanders c) Output expanders

More information

CONCEPT 3000/Access 4000 User Manual UK Supplement

CONCEPT 3000/Access 4000 User Manual UK Supplement CONCEPT 3OOO & Access 4000. 1 CONCEPT 3000/Access 4000 User Manual UK Supplement Revision 5.70 This manual is intended for use in conjunction with the Concept 4000 User Manual, Revision 5.6 or later. CONTENTS

More information

User Guide. Connect2Go User Guide rev1.0 PO Box 3382 Station Main, Meaford Ontario N4L 1A5 T: (+1)

User Guide. Connect2Go User Guide rev1.0 PO Box 3382 Station Main, Meaford Ontario N4L 1A5 T: (+1) User Guide Contents 1.0 About This Guide... 4 2.0 Accessing Your Connect2Go Account From a Web Browser... 4 2.1. Account Login... 4 2.2. Landing Page... 4 2.3. Left Vertical Menu and Device View... 4 2.4.

More information

PROGRAMMING HELP GUIDE

PROGRAMMING HELP GUIDE DIGIPLEX EVO48-192 PROGRAMMING HELP GUIDE Entering Programming Mode 1) Press and hold the [0] key 2) Enter your [Installer Code] (default-000000) 3) Enter 4-digit [section] you wish to program 4) Enter

More information

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL

More information

INT-RS module - short technical description

INT-RS module - short technical description INT-RS module - short technical description The module INT-RS is dedicated to work with INTEGRA panels with firmware v1.06 2008-01-08 or above. It is an INTEGRA (LCD) bus to RS-232 converter. To properly

More information

2 IDS LCD Keypad User Manual C Issued March 2009

2 IDS LCD Keypad User Manual C Issued March 2009 2 3 4 Contents 1. Introduction to the IDS LCD Digital Keypad...8 2. Arming the Control Panel...8 2.1 Away Arming...8 2.1.1 How to Away Arm...8 2.1.2 Quick Away Arm Shortcut Key...8 2.2 Stay Arming...9

More information

Total Connect User Guide K /09 Rev. C

Total Connect User Guide K /09 Rev. C K14741 12/09 Rev. C Total Connect User Guide TRADEMARKS Honeywell is a registered trademark of Honeywell International Inc. Windows and Windows Vista are trademarks, or registered trademarks of Microsoft

More information

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web: ACCESS CONTROL QUICK INSTALL GUIDE tel: +44 (0)1457 874 999 fax: +44 (0)1457 829 201 email: sales@cop-eu.com web: www.cop-eu.com WIRING CONFIGURATION - ACS CONTROLLERS CONNECTIONS Dahua access controllers

More information

USER MANUAL. Disclaimer

USER MANUAL. Disclaimer USER MANUAL Disclaimer The instructions in this document have been carefully checked for accuracy and are presumed to be reliable. Smart I Electronics Systems Pvt. Ltd. and its writers assume no responsibility

More information

M1 APPLICATION NOTE. Access Control Interface to Ness IP Access Control Systems (i.e. Edge, V2000 and V1000 Controllers)

M1 APPLICATION NOTE. Access Control Interface to Ness IP Access Control Systems (i.e. Edge, V2000 and V1000 Controllers) M1 APPLICATION NOTE Access Control Interface to Ness IP Access Control Systems (i.e. Edge, V2000 and V1000 Controllers) The M1 can interface with the Ness IP Access Control Series of controllers (Edge,

More information

PROGRAMMING AND INSTALLATION MANUAL

PROGRAMMING AND INSTALLATION MANUAL PROGRAMMING AND INSTALLATION MANUAL Keypad LCD-S (software version 3.10) CA-10 plus GDAŃSK ca10plci_s_e 09/03 WARNING Due to safety reasons, alarm system should be installed by qualified personnel only.

More information

EVOHD. Programming Guide. Version

EVOHD. Programming Guide. Version EVOHD Programming Guide Version 1.11 www.paradox.com Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on our Web site: www.paradox.com. Your

More information

TouchOne Mini User s Guide

TouchOne Mini User s Guide TouchOne Mini User s Guide Contents 1 Introduction 6 1.1 Product Summary 6 1.2 Version 7 1.3 Features not covered 7 2 General Usage 8 2.1 Home Screen 8 2.2 Keypad Screen 10 2.3 Arming the System 12 2.3.1

More information

Keypad LCD-L (software version 3.10) CA-10 plus

Keypad LCD-L (software version 3.10) CA-10 plus PROGRAMMING AND INSTALLATION MANUAL Keypad LCD-L (software version 3.10) CA-10 plus GDAŃSK ca10plci_l_e 09/03 WARNING Due to safety reasons, alarm system should be installed by qualified personnel only.

More information

Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules

Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules This guide supplements the Synergis Master Controller Configuration Guide and explains how to configure Axis interface modules

More information

New Product Announcement

New Product Announcement New Product Announcement KT-400 Ethernet-Ready Four-Door Controller with Standalone Mode Johnson Controls is pleased to announce that Kantech s KT-400 four door controller is now available to operate in

More information

IDS X-Series User Manual E Issued June 2013

IDS X-Series User Manual E Issued June 2013 1 2 Contents 1. Introduction to the IDS X-Series Panels... 6 2. Before Operating Your Alarm System... 6 3. Understanding the Keypad LEDs... 7 3.1 Viewing Data on an LED Keypad... 11 3.2 Entering Data on

More information

WebStation User Manual

WebStation User Manual DN1709-1107/ Version 5.00 Copyright 2011 Tyco International Ltd. and its respective companies. All Rights Reserved. All specifications were current as of publication date and are subject to change without

More information

Bosch Intrusion Panel Integration Guide

Bosch Intrusion Panel Integration Guide B-Series/G-Series intrusion panel for use with B93x/B93x and B91x/B92x keypads. (Test reference: model B5512 control panel and B920 keypad) Overview exacqvision can be integrated with Bosch B and G-Series

More information

Stay connected to your home or business. Connect remotely from anywhere in the world.

Stay connected to your home or business. Connect remotely from anywhere in the world. Total Connect User Guide Stay connected to your home or business. Connect remotely from anywhere in the world. K14741 3/09 Rev. B TRADEMARKS Honeywell is a registered trademark of Honeywell International

More information

S P E C I A L E D I T I O N E N T R A P A S S TM

S P E C I A L E D I T I O N E N T R A P A S S TM S P E C I A L E D I T I O N E N T R A P A S S TM Architectural and Engineering Specifications Access Control and Integrated Systems DN1610-1004 / Version 4.03 TABLE OF CONTENTS PART I GENERAL... 3 1.1

More information

Wireless Alarm System User Guide

Wireless Alarm System User Guide Wireless Alarm System User Guide Alarm Panel Time 10:09 c RINS1902 Document SAP: 102015108-03 Contents ProControl+ 4 Setting Devices 5 The Wireless Panel Keypad 5 Wireless Keyfobs 5 Locking the Keyfob

More information

EntraPass WebStation. User Manual DN

EntraPass WebStation. User Manual DN EntraPass WebStation User Manual DN1709-1011 EntraPass WebStation User Manual Table of Contents General Information...1 Copyright Information...1 EntraPass WebStation Documentation...1 Related Documentation...1

More information

User manual. Misterhouse

User manual. Misterhouse DSC Alarm PC5401 Serial Module User manual Misterhouse DSC Alarm PC5401 Serial Module Version 1.2 2005-01-31 DSC Alarm PC5401 Serial Module http://misterhouse.net/ AUTHOR Gaétan Lord Jocelyn Brouillard

More information

Envisalink4/Honeywell Vista Installation and Programming Guide

Envisalink4/Honeywell Vista Installation and Programming Guide Envisalink4/Honeywell Vista Installation and Programming Guide This document outlines how to connect your Envisalink4 to a Honeywell Vista Panel (10P/15P/20P/21iP/128/150) and to initially program your

More information

Modules Programming Guide

Modules Programming Guide Modules Programming Guide Programming Methods The modules can be programmed using the following methods: 1) Through the WinLoad Security Management Software. The modules can be programmed at 19,200 baud

More information

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote... Contents 1. Introduction to the Watchguard WGAP864 LCD Digital Keypad... 6 2. Viewing Violated Zones... 6 3. Arming the Control Panel... 7 3.1 Away Arming... 7 3.1.1 How to Away Arm... 7 3.1.2 Quick Away

More information

Access Easy Controller 2.1 APC-AEC21-UPS1. Software Manual

Access Easy Controller 2.1 APC-AEC21-UPS1. Software Manual Access Easy Controller 2.1 APC-AEC21-UPS1 en Software Manual Access Easy Controller 2.1 Table of Contents en 3 Table of Contents 1 Introduction 9 1.1 Access Easy Controller 2.1 Functional Features 9 1.2

More information

New Product Announcement EntraPass v7.10 Software

New Product Announcement EntraPass v7.10 Software New Product Announcement EntraPass v7.10 Software Tyco Security Products is pleased to announce version 7.10 of Kantech s flagship EntraPass security management system software. We continue to build upon

More information

Technical documentation

Technical documentation Document type: Technical documentation Scope: Galaxy Integration Product: IFTER EQU Prepared: 2015 1 Contents 1.0 IFTER EQU Visualization software 4 2.0 Honeywell Galaxy control units visualization 6 3.0

More information

Access Control and Security Management Software Release Notes

Access Control and Security Management Software Release Notes Access Control and Security Management Software Release Notes DN1525-1310 / Version 6.01 Copyright 2013 Tyco International Ltd. and its Respective Companies. All Rights Reserved. All specifications were

More information

Installer Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE

Installer Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE Installer Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE 1. Programming can only be done with a 6139 Alpha Keypad on Vista-10/20/30PSE models. 2. When entering programming for the first time during Installations

More information

Update: Protection One OnLine Access now also offers the ability to make changes or additions to contacts on your account.

Update: Protection One OnLine Access now also offers the ability to make changes or additions to contacts on your account. Welcome to Protection One s convenient OnLine Access service! Our OnLine Access allows you to view your account information through a standard Web browser. In addition, if you subscribe to receive reports,

More information

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): MAXSYS Series

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): MAXSYS Series Manufacturer: DSC Integration Note Model Number(s): MAXSYS Series Core Module Versions: 4.0 (all builds) Comments: Document Revision Date: 1/30/2013 OVERVIEW AND SUPPORTED FEATURES The DSC MAXSYS Series

More information

Bosch solution 6000 cheat sheets

Bosch solution 6000 cheat sheets Adding a token to a user Select add token and user if prompted by keypad select reader Menu 120 Select door/s that the user will have access to (if applicable) Menu 145 Select areas that the user will

More information

TM50 Touch Intuitive Touchscreen

TM50 Touch Intuitive Touchscreen TM50 Touch Intuitive Touchscreen Description With its bright color display, intuitive icons, and menu-driven interface, the TM50 Touch Intuitive Touchscreen reflects Paradox s commitment to user-centric

More information

PROGRAMMING. Alarm Control Panel. SATEL sp. z o.o. ul. Budowlanych Gdańsk POLAND tel Firmware Version 1.

PROGRAMMING. Alarm Control Panel. SATEL sp. z o.o. ul. Budowlanych Gdańsk POLAND tel Firmware Version 1. Alarm Control Panel Firmware Version 1.01 PROGRAMMING perfecta_p_en 10/17 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. +48 58 320 94 00 www.satel.eu Before you start programming, please

More information

Installation Guide. ZKAccess CLASSIC 3.5. www. zkaccess.com

Installation Guide. ZKAccess CLASSIC 3.5. www. zkaccess.com Installation Guide ZKAccess CLASSIC.5 www. zkaccess.com Contents Downloading... Installation & Adding an Area...4 Adding an Area...5 Adding a Device...6 To add a standalone device:... 6 To add an Access

More information

Lab 5: Access Control Training Station

Lab 5: Access Control Training Station Lab 5: Access Control Training Station Learning Objectives At the end of the lab, trainees should be able to: 1. Understand the functional block and hardware of an access control system. 2. Understand

More information

Applicable to the EURO 46, 76, 162 and 280 control panels, software V9 or above.

Applicable to the EURO 46, 76, 162 and 280 control panels, software V9 or above. Applicable to the EURO 46, 76, 162 and 280 control panels, software V9 or above. Please note that this manual has been prepared to highlight the new PD6662, BS8243 and EN50131-1 features. RINS1530-1 CHAPTER

More information

INT-GSM. GPRS communication module. Firmware version 1.00 int-gsm_en 07/18

INT-GSM. GPRS communication module. Firmware version 1.00 int-gsm_en 07/18 INT-GSM GPRS communication module Firmware version 1.00 int-gsm_en 07/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. +48 58 320 94 00 www.satel.eu IMPORTANT The module should be installed

More information

SK-NET. Version 2. Installation and Operating Manual

SK-NET. Version 2. Installation and Operating Manual SK-NET Version 2 Installation and Operating Manual Version Note: This manual covers features available in SK-NET Version 2.40. A few features described in this manual are only available with SK-ACP and

More information

PR402 v1.0 SINGLE DOOR ACCESS CONTROLLER

PR402 v1.0 SINGLE DOOR ACCESS CONTROLLER PR402 v1.0 SINGLE DOOR ACCESS CONTROLLER FIRMWARE VERSION 117.0 Installation Manual MASCO Biztonságtechnikai és Nyílászáró Automatizálási Kereskedelmi Kft. 1045 Budapest, Madridi út 2. Tel: (06 1) 3904170,

More information

SILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad.

SILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad. S Y S T E M U S E R G U I D E SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad. IS THIS A FALSE ALARM? YES NO displays. REAL ALARM

More information

ACCO SOFT. Configuration program for ACCO NET access control system. User Manual

ACCO SOFT. Configuration program for ACCO NET access control system. User Manual ACCO SOFT Configuration program for ACCO NET access control system User Manual Program version 1.15.8 acco soft_en 11/17 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. +48 58 320 94 00 www.satel.eu

More information

to that area and whether or not the Cardax FT GBUS URI (Standard or person holds these competencies. Wiegand variant)

to that area and whether or not the Cardax FT GBUS URI (Standard or person holds these competencies. Wiegand variant) The Cardax FT Controller 6000 is a powerful modular, intelligent field controller for processing, storing and communicating large amounts of data in real time, independently of the Cardax FT Command Centre

More information

Series. NX-8-EUR Control Panel. Installation manual

Series. NX-8-EUR Control Panel. Installation manual g GE Security NetworX TM Series NX-8-EUR Control Panel Installation manual NX-8-EUR Installation manual Page 2 23/12/04 CONTENTS CONTENTS...3 GENERAL INFORMATION...5 ORDERING INFORMATION...5 FEATURE DEFINITIONS...6

More information

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

Safecom Solution-16 Quick Reference Guide ISSUE 1.10 Safecom Solution-16 Quick Reference Guide ISSUE 1.10 2 Solution-16 Safecom Quick Reference Guide Safecom Solution-16 Quick Reference Guide Copyright 1998 by, SYDNEY, AUSTRALIA Document Part Number MA8016Q

More information

Antipassback, Parking and Access Areas. Technical Support Engineering Rosslare Security NA For more information please see

Antipassback, Parking and Access Areas. Technical Support Engineering Rosslare Security NA For more information please see Antipassback, Parking and Access Areas Technical Support Engineering Rosslare Security NA For more information please see www.axtraxng.com Antipassback prevents a user from using the same credential multiple

More information

XT30/XT50 OVERVIEW. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training System Overview. XT30/XT50 Description

XT30/XT50 OVERVIEW. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training System Overview. XT30/XT50 Description Slide 1 XT30/XT50 Basic Training System Overview Slide 2 Objectives After completing this course you will be able to: 1) Understand the basic features of the panel. 2) Understand the different modes of

More information

G L O B A L E D I T I O N E N T R A P A S S TM

G L O B A L E D I T I O N E N T R A P A S S TM G L O B A L E D I T I O N E N T R A P A S S TM Architectural and Engineering Specifications Access Control and Integrated Systems DN1606-1004 / Version 4.03 TABLE OF CONTENTS PART I GENERAL... 4 1.1 GENERAL

More information

C O R P O R A T E E D I T I O N E N T R A P A S S TM

C O R P O R A T E E D I T I O N E N T R A P A S S TM C O R P O R A T E E D I T I O N E N T R A P A S S TM Architectural and Engineering Specifications Access Control and Integrated Systems DN1609-1004 / Version 4.03 TABLE OF CONTENTS PART I GENERAL... 4

More information

C24 Installation and Activation

C24 Installation and Activation C24 Installation and Activation March 5, 2012 Agenda Brief overview of installation process for: o DSC Power Series 1864 + Gateway Live activation demo after this overview This overview assumes previous

More information

EC-11 Ethernet Converter

EC-11 Ethernet Converter EC-11 Ethernet Converter PSTN Contact ID to TCP Converter Installation and Operations Manual Version 8.H3.MID 1 Table of Contents About EC-11 Ethernet Converter... 3 Circuit Board Layout and Wiring Diagram...

More information

Colour Graphic Terminal User Manual. Rev 3.1

Colour Graphic Terminal User Manual. Rev 3.1 Integriti. Colour Graphic Terminal User Manual. 1 Colour Graphic Terminal User Manual. Rev 3.1 2013-2014. Inner Range Pty. Ltd. Part Number: 636000U 2 Integriti. Revision 3.1 June 2014. SYSTEM DETAILS

More information

VISTA-20SEa. 3-Partition Security System. Programming Form. V20SEaPRV1 9/98

VISTA-20SEa. 3-Partition Security System. Programming Form.   V20SEaPRV1 9/98 VISTA-20SEa 3-Partition Security System New style cover to be used Programming Form V20SEaPRV1 9/98 Local programming requires the use of a 2-line Alpha keypad connected to Partition 1 keypad terminals

More information

New Product Announcement EntraPass v7.10/7.11 Software

New Product Announcement EntraPass v7.10/7.11 Software New Product Announcement EntraPass v7.10/7.11 Software Tyco Security Products is pleased to announce version 7.10 of Kantech s flagship EntraPass security management system software. We continue to build

More information

ACTsmart2 Product Range Operating and Installation Instructions

ACTsmart2 Product Range Operating and Installation Instructions ACTsmart2 Product Range Operating and Installation Instructions 18-00045 Contents ORDERING INFORMATION......4 INSTALLATION NOTES......5 IMPORTANT......5 PRODUCT SPECIFICATION......5 30 SECOND PROGRAMMING

More information

Modules Programming Guide. paradox.com

Modules Programming Guide. paradox.com Keypad Modules Annunciator Module Motion Detector Modules Zone Expansion Modules Access Control Module Voice Assisted Modules Accessory Modules Integration Module Internet Module Modules Programming Guide

More information

LCD User Station User Manual

LCD User Station User Manual LCD User Station User Manual PUBLICATION INFORMATION 504A R Final Release CONTENTS 1.0 INTRODUCTION... 4 1.1 Legend... 2.2 Terminology... 2.0 OPERATION... 8 2.1 Indicator Lights... 2.2 Visual Display...

More information

USER GUIDE. for ios Version 1. alula.net ALULA 1

USER GUIDE. for ios Version 1. alula.net ALULA 1 USER GUIDE for ios Version 1 alula.net 1-888-88-ALULA 1 1. GETTING STARTED 3 2. DOWNLOAD THE ALULA APP 3 3. SIGN IN 3 4. 4. LOCATIONS 4 5. MAIN DASHBOARD SCREEN 5 5.1. Application Menu 5 5.3. Feature Menus

More information

4.2. LockView N. Instruction Man

4.2. LockView N. Instruction Man 4.2 Manual n io t c u r t s TC In LockView N ual Instruction Man Table of Contents LockView NTC 4.2 Operator s Manual LockView NTC Instruction Manual LockView NTC Instruction Manual Introduction... 4 Operation...

More information

Wednesday, October 07, WebBrix. Admin Guide

Wednesday, October 07, WebBrix. Admin Guide Wednesday, October 07, 2015 WebBrix Admin Guide Contents 3 Table of Contents Foreword Part I Web Client 0 4 1 Monitor/Command... 5 Events... 5 Status... 7 HID Edge and... Edge EVO 8 HID V1000 and... V1000

More information

LIFT CONTROL WITH FLOOR BUTTON FEEDBACK (V3 OR LATER)

LIFT CONTROL WITH FLOOR BUTTON FEEDBACK (V3 OR LATER) Applications Programming Guide - LIFT CONTROL WITH BUTTON FEEDBACK. Rev 4.51 Page 1 LIFT CONTROL WITH FLOOR BUTTON FEEDBACK (V3 OR LATER) Lift control logic can be used to control Floor security for a

More information