1 Hitachi Compute Blade Emulex Adapter User's Guide for Utility FASTFIND LINKS Getting Help Contents MK-99COM105-15

2 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or stored in a database or retrieval system for any purpose without the express written permission of Hitachi, Ltd. Hitachi, Ltd., reserves the right to make changes to this document at any time without notice and assumes no responsibility for its use. This document contains the most current information available at the time of publication. When new or revised information becomes available, this entire document will be updated and distributed to all registered users. Some of the features described in this document might not be currently available. Refer to the most recent product announcement for information about feature and product availability, or contact Hitachi Data Systems Corporation at Notice: Hitachi, Ltd., products and services can be ordered only under the terms and conditions of the applicable Hitachi Data Systems Corporation agreements. The use of Hitachi, Ltd., products is governed by the terms of your agreements with Hitachi Data Systems Corporation. Hitachi is a registered trademark of Hitachi, Ltd., in the United States and other countries. Hitachi Data Systems is a registered trademark and service mark of Hitachi, Ltd., in the United States and other countries. Archivas, Essential NAS Platform, HiCommand, Hi-Track, ShadowImage, Tagmaserve, Tagmasoft, Tagmasolve, Tagmastore, TrueCopy, Universal Star Network, and Universal Storage Platform are registered trademarks of Hitachi Data Systems Corporation. AIX, AS/400, DB2, Domino, DS8000, Enterprise Storage Server, ESCON, FICON, FlashCopy, IBM, Lotus, OS/390, RS6000, S/390, System z9, System z10, Tivoli, VM/ESA, z/os, z9, zseries, z/vm, z/vse are registered trademarks and DS6000, MVS, and z10 are trademarks of International Business Machines Corporation. All other trademarks, service marks, and company names in this document or website are properties of their respective owners. Microsoft product screen shots are reprinted with permission from Microsoft Corporation. ii

3 Contents Preface... v Document Conventions... vi Getting Help... ix Comments... ix Overview of This Manual Flow Chart of Setting up The OneCommand Manager application GUI (in Windows) The OneCommand Manager application CLI (in Linux) Supported Operating Systems Restrictions Acronyms and Abbreviations... Glossary-1 Contents iii

4

5 Preface Thank you very much for purchasing the Hitachi Compute blade. This document describes how to use the management utility for Emulex adapters. This preface includes the following information: Document Conventions Getting Help Comments Preface v

6 Document Conventions This document uses the following typographic conventions: Convention Bold Italic screen/code Description Indicates text on a window, other than the window title, including menus, menu options, fields, and labels. Example: Click OK. Indicates a variable, which is a placeholder for actual text provided by the user or system. Example: copy source-file target-file Note: Angled brackets (< >) are also used to indicate variables. Indicates text that is displayed on screen or entered by the user. Example: # pairdisplay -g oradb < > angled brackets Indicates a variable, which is a placeholder for actual text provided by the user or system. Example: # pairdisplay -g <group> Note: Italic font is also used to indicate variables. [ ] square brackets Indicates optional values. Example: [ a b ] indicates that you can choose a, b, or nothing. { } braces Indicates required or expected values. Example: { a b } indicates that you must choose either a or b. vertical bar Indicates that you have a choice between two or more options or arguments. Examples: [ a b ] indicates that you can choose a, b, or nothing. { a b } indicates that you must choose either a or b. underline Indicates the default value. Example: [ a b ] This document uses the following icons to draw attention to information: Icon Meaning Description NOTICE WARNING CAUTION NOTICE This indicates the presence of a potential risk that might cause death or severe injury. This indicates the presence of a potential risk that might cause relatively mild or moderate injury. This indicates the presence of a potential risk that might cause severe damage to the equipment and/or damage to surrounding properties. Note This indicates notes not directly related to injury or severe damage to equipment. Tip This indicates advice on how to make the best use of the equipment. vi Preface

7 Abbreviated Notations of Operating Systems (OS) In this manual, OS names are expressed as follows: Microsoft(R) Windows Server(R) 2012 R2 Standard (Windows Server 2012 R2 hereafter) Microsoft(R) Windows Server(R) 2012 R2 Datacenter (Windows Server 2012 R2 hereafter) Microsoft(R) Windows Server(R) 2012 Standard (Windows Server 2012 hereafter) Microsoft(R) Windows Server(R) 2012 Datacenter (Windows Server 2012 hereafter) Microsoft(R) Windows Server(R) 2008 Standard 32-bit (Windows Server 2008 (32bit) hereafter) Microsoft(R) Windows Server(R) 2008 Enterprise 32-bit (Windows Server 2008 (32bit) hereafter) Microsoft(R) Windows Server(R) 2008 Standard (Windows Server 2008 hereafter) Microsoft(R) Windows Server(R) 2008 Enterprise (Windows Server 2008 hereafter) Microsoft(R) Windows Server(R) 2008 Standard without Hyper-VTM 32-bit (Windows Server 2008 (32bit) hereafter) Microsoft(R) Windows Server(R) 2008 Enterprise without Hyper-VTM 32-bit (Windows Server 2008 (32bit) hereafter) Microsoft(R) Windows Server(R) 2008 Standard without Hyper-VTM (Windows Server 2008 hereafter) Microsoft(R) Windows Server(R) 2008 Enterprise without Hyper-VTM (Windows Server 2008 hereafter) Microsoft(R) Windows Server(R) 2008 R2 Standard (Windows Server 2008 R2 hereafter) Microsoft(R) Windows Server(R) 2008 R2 Enterprise (Windows Server 2008 R2 hereafter) Microsoft(R) Windows Server(R) 2008 R2 Datacenter (Windows Server 2008 R2 hereafter) Red Hat(R) Enterprise Linux(R) Server 7.2 (RHEL7.2 hereafter) Red Hat(R) Enterprise Linux(R) Server 7.1 (RHEL7.1 hereafter) Red Hat(R) Enterprise Linux(R) Server 6.7 (RHEL6.7 hereafter) Red Hat(R) Enterprise Linux(R) Server 6.6 (RHEL6.6 hereafter) Red Hat(R) Enterprise Linux(R) Server 6.5 (RHEL6.5 hereafter) Red Hat(R) Enterprise Linux(R) Server 6.4 (RHEL6.4 hereafter) Preface vii

8 Red Hat(R) Enterprise Linux(R) Server 6.2 (RHEL6.2 hereafter) Red Hat(R) Enterprise Linux(R) Server 5.9 (RHEL5.9 hereafter) Red Hat(R) Enterprise Linux(R) Server 5.7 (RHEL5.7 hereafter) Abbreviations for 10Gb Converged Network Expansion Cards Abbreviations for the following card model names are written in this manual. Abbreviation "onboard CNA" : CB500 series server blade onboard CNA CB2500 series server blade onboard CNA Abbreviation "CNA expansion card" : CB500 4-port converged network expansion card CB2000 2/4-port converged network expansion card CB2000 CNA board (PCI express adapter type) CB2500 CNA board (PCI express adapter type) Abbreviation "LAN expansion card" : CB500 10Gb 4-port LAN expansion card CB Gb 2/4-port LAN expansion card Abbreviation for Fiber Channel (FC) Card Abbreviation for the following FC card model name is written in this manual. Abbreviation "8Gb FC expansion card" CB500 8Gb 2-port Fiber Channel expansion card CB2000 8Gb 2-port Fiber Channel expansion card CB2000 8Gb 2-port Fibre Channel board (PCI express adapter type) CB2500 8Gb 2-port Fibre Channel board (PCI express adapter type) Abbreviation "8Gb FC board" CB2000 8Gb 2-port Fibre Channel board (PCI express adapter type) CB2500 8Gb 2-port Fibre Channel board (PCI express adapter type) Abbreviation "16Gb FC expansion card" CB500 16Gb 2-port Fiber Channel expansion card CB Gb 2-port Fibre Channel board (PCI express adapter type) CB Gb 2-port Fibre Channel board (PCI express adapter type) Abbreviation "16Gb FC board" CB Gb 2-port Fibre Channel board (PCI express adapter type) CB Gb 2-port Fibre Channel board (PCI express adapter type) Abbreviation "FC expansion card" 8Gb FC expansion card 16Gb FC expansion card 8Gb FC board 16Gb FC board viii Preface

9 Getting Help The Hitachi Data Systems customer support staff is available 24 hours a day, seven days a week. If you need technical support, log on to the Hitachi Data Systems Portal for contact information: Comments Please send us your comments on this document: doc.comments@hds.com. Include the document title and number including the revision level (for example, -07), and refer to specific sections and paragraphs whenever possible. All comments become the property of Hitachi Data Systems Corporation. Thank you! Preface ix

10

11 1 Overview of This Manual This manual describes the management utility for the Emulex products Hitachi Compute Blade Emulex Adapter User's Guide Overview of This Manual 1-1

12 Hitachi Compute Blade Emulex Adapter User's Guide Hitachi Compute Blade Emulex Adapter User's Guide is the manual for the following products. # System Model Products Product Code Remarks 1 CB A B1 Onboard CNA GGAGD0B1-TNNX14Y 2 series 520H B1 Onboard CNA GGAGC0B1-TNNX14Y 3 520H B2 Onboard CNA GG-RV3XGC0B2X1-Y 4 520H B3 Onboard CNA GG-RV3XGC0B3X1-Y 5 520H B4 Onboard CNA GG-RV3XGC0B4X1-Y 6 520X B1 Onboard CNA GG-RV3XGE0B1X1-Y 7 520X B2 Onboard CNA GG-RV3XGE0B2X1-Y 8 CNA expansion card GG-CN3MXG2X1-Y 9 GGX-CN3MXG2X1[EX] 10 GGX-CN3MXG2X3[EX] 11 LAN expansion card GG-CN3MXG2X2-Y 12 GGX-CN3MXG2X2[EX] 13 GGX-CN3MXG2X4[EX] 14 8Gb FC expansion card GG-CC3M8G1X1-Y 15 GGX-CC3M8G1X1[EX] 16 16Gb FC expansion card GG-CC3M161X1-Y 17 GGX-CC3M161X1[EX] 18 CB2000 CNA board GV-CN2NXG3X1-Y 19 series (for chassis) GV-CN2NXG3XR-Y for RoHS 20 GVX-CN2NXG3X1[BX] 21 GVX-CN2NXG3X2[BX] for CB2000 x4 model 22 CNA board GV-CN2DXG3X1-Y 23 (for I/O slot expansion unit) GVX-CN2DXG3X1[EX] 24 GVX-CN2DXG3X2[EX] for CB2000 x4 model 25 LAN expansion card (2-port) GV-CN2MXG1X1-Y 26 GVX-CN2MXG1X1[EX] 27 GVX-CN2MXG1X2[EX] for CB2000 x4 model 28 LAN expansion card (4-port) GV-CN2MXG2X1-Y 29 GVX-CN2MXG2X1[EX] 30 GVX-CN2MXG2X2[EX] for CB2000 x4 model 31 CNA expansion card (2-port) GV-CN2MXG3X1-Y 32 GVX-CN2MXG3X1[EX] 33 GVX-CN2MXG3X2[EX] for CB2000 x4 model 34 CNA expansion card (4-port) GV-CN2MXG4X1-Y 35 GVX-CN2MXG4X1[EX] 36 GVX-CN2MXG4X2[EX] for CB2000 x4 model 37 8Gb FC board GV-CC2N8G3X1-Y 38 (for chassis) GV-CC2N8G3XR-Y for RoHS 39 GVX-CC2N8G3X1[BX] 40 8Gb FC board GV-CC2D8G3X1-Y 41 (for I/O slot expansion unit) GVX-CC2D8G3X1[EX] 42 8Gb FC expansion card GV-CC2M8G3X1-Y 43 GV-CC2M8G3XR-Y for RoHS 44 GVX-CC2M8G3X1[EX] 45 16Gb FC board GV-CC2N163X1-Y 46 (for chassis) GVX-CC2N163X1[BX] 47 16Gb FC board GV-CC2D163X1-Y 48 (for I/O slot expansion unit) GVX-CC2D163X1[EX] 49 CB H B3 Onboard CNA GG-RV3XGC0B3X1-Y 50 series 520H B4 Onboard CNA GG-RV3XGC0B4X1-Y X B1 Onboard CNA GG-RV3XGE0B1X1-Y X B2 Onboard CNA GG-RV3XGE0B2X1-Y X B3 Onboard CNA GG-RV3XGE0B3X1-Y 54 CNA board GG-CN4NXG3X1-Y 1-2 Overview of This Manual

13 55 8Gb FC board GG-CC4N8G3X1-Y 56 16Gb FC board GG-CC4N163X1-Y Hitachi Compute Blade Emulex Adapter User's Guide consists of three documents : for Driver, for Hardware and for Utility. See the document "Hitachi Compute Blade LAN Advanced Function Manual for Emulex (MK-99COM082)" for how to setup the NIC teaming and how to setup the VLAN. # Document Name Contents Hitachi Compute Blade Emulex How to install the drivers of the adapters 1 Adapter User's Guide for Driver (MK-99COM103) How to setup the drivers Hitachi Compute Blade Emulex Adapter User's Guide for Hardware (MK-99COM104) Hitachi Compute Blade Emulex Adapter User's Guide for Utility (MK-99COM105) Hitachi Compute Blade LAN Advanced Function Manual for Emulex (MK-99COM082) Outline of Emulex adapters BIOS parameter list and the way to configure the parameters This document. How to install and to operate the utility that manages the Emulex adapters How to configure the parameters with the utility How to setup the NIC teaming How to setup the VLAN Overview of This Manual 1-3

14

15 2 Flow Chart of Setting up This chapter describes the flow chart of setting up for Emulex adapters. The flow chart of setting up for onboard CNA / CNA expansion card / LAN expansion card The flow chart of setting up for 8Gb / 16Gb Fibre Channel expansion card Flow Chart of Setting up 2-1

16 The Flow Chart of Setting up for Onboard CNA / CNA expansion card / LAN expansion card The flow chart of setting up for onboard CNA / CNA expansion card / LAN expansion card is as follows. Start Enabling PXE Disabling PXE Setting Personality Enabling multichannel function Disabling Multichannel function Setting iscsi initiator See "Hitachi Compute Blade Emulex Adapter User's Guide for Hardware" Setting iscsi target (for boot) Setting iscsi target (for data) Setting FCoE Setting FCoE (for booting) Setting FCoE (for data) Setup of OS See "OS Installation Guide" for each OS. NIC driver iscsi driver See "Hitachi Compute Blade Emulex Adapter User's Guide for Driver" FCoE driver Settings by OCM/OCM_CLI In this document, see the chapter 3 or chapter4. Settings by NIC Teaming Kit Teaming setting VLAN setting See "Hitachi Compute Blade LAN Advanced function manual for Emulex" 2-2 Flow Chart of Setting up End

17 The Flow Chart of Setting up for 8Gb / 16Gb FC expansion card The setting flow of 8Gb / 16Gb FC expansion card is as follows Start Setting Fibre Channel Device boot configuration for FC device See "Hitachi Compute Blade Emulex Adapter User's Guide for Hardware" OS Setting up See "OS Installation Guide" for each OS. Installing Driver See "Hitachi Compute Blade Emulex Adapter User's Guide for Driver" Configurations by OCM/OCM_CLI Configuring the driver parameters. In this document, see the chapter 3 or chapter 4. End Flow Chart of Setting up 2-3

18

19 3 The OneCommand Manager application GUI (in Windows) This chapter describes the OneCommand Manger application GUI (OCM hereafter) for Emulex adapters. OCM version List Installing OCM Uninstalling OCM Confirming OCM version Starting OCM Stopping OCM OCM functions Configuring by OCM The OneCommand Manager application GUI (in Windows) 3-1

20 OCM version List Supported OCM versions are as follows. Table 3-1 : No. Supported OCM version Remarks or or or Only for : CB500 CB520X B1 CB500 CB520X B2 CB500 CB520H B Only for : CB2500 CB520X B1 CB2500 CB520X B2 CB2500 CB520H B3 CB500 CB520H x2 CB500 CB520X B1 CB500 CB520X B2 CB500 CB520H B3 CB500 CB520H B4 CB2500 CB520X B1 CB2500 CB520X B2 CB2500 CB520H B3 CB2500 CB520H B4 3-2 The OneCommand Manager application GUI (in Windows)

21 Installing OCM This section describes the OCM installation procedure. The following description assumes that user logs on with administrator privilege (such as Administrator). The OCM has been installed to the OS preinstalled system with onboard CNA, CNA expansion card or LAN expansion card. Install OCM when reinstalling OS or installing the Emulex adapters newly to the system. The drivers and OCM are provided with CD/DVD media : "10Gb CNA Driver CD". 1. Start OCM and confirm the version. Windows Server 2008 / Windows Server 2008 R2 : Select Start All programs Emulex OCManager. Windows Server 2012 / Windows Server 2012 R2 : Select Start OCManager. 2. Click Help About OneCommand(TM) Manager and confirm the version. Confirm that the version is listed in Table 3-1. When the version is supported, the installation is not necessary. When upgrading or downgrading, go to next step. When reinstalling, go to next step after uninstalling. The uninstalling process is describes in the section "Uninstalling OCM". 3. Insert the driver media into the DVD-ROM drive, and open the following folder. Table 3-2: - CB500 CB520AA1, CB520H x1, CB540A x1 model : "CB500 10Gb CNA Driver CD ver.01-13(or higher)" media : OCM version Location of the installation file OS or \WinSrv2008\Utility\OCM Windows Server 2008 (32bit) Windows Server 2008 Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 - CB500 CB520H B2 model: "CB500 10Gb CNA Driver CD ver.01-19(or higher)" media OCM version Location of the installation file OS or \WinSrv2008\Utility\OCM Windows Server 2008 (32bit) Windows Server 2008 Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R \WinSrv2008\Utility\OCM_3 Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 The OneCommand Manager application GUI (in Windows) 3-3

22 - CB500 CB520X B1/ CB520X B2/CB520H B3 model: "CB500 10Gb CNA Drivers ver.01-19(or higher)" media : OCM version Location of the installation file OS or \WinSrv2008\Utility\OCM_2 Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R \WinSrv2008\Utility\OCM_3 Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 - CB500 CB520H B4 model: "CB500 10Gb CNA Drivers ver.01-21(or higher)" media : OCM version Location of the installation file OS \WinSrv2008\Utility\OCM_3 Windows Server 2012 Windows Server 2012 R2 - CB2500 CB520X B1/520X B2/520H B3 model: "CB Gb CNA Drivers ver.01-19(or higher)" media : OCM version Location of the installation file OS or \WinSrv2008\Utility\OCM_2 Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R \WinSrv2008\Utility\OCM_3 Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 - CB2000 Standard server blade x3 model : " Server installation and monitoring tool " media : OCM version Location of the installation file OS or See the file "support_en.html" in the root folder. - CB2000 High performance server blade, Standard server blade x4 model: " Server installation and monitoring tool " media : Windows Server 2008 (32bit) Windows Server 2008 Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 OCM version Location of the installation file OS or See the file "support_en.html" in the root folder. 4. Execute the following script file. Table 3-3: Windows Server 2008 (32bit) Windows Server 2008 Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 Script file OS OneCommandManager_Install_x86.bat Windows Server 2008 (32bit) OneCommandManager_Install_x64.bat Windows Server 2008 Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 5. The installation starts automatically. Wait until Emulex OCManager Enterprise on the task bar disappears. When Emulex OCManager Enterprise disappears, the installation is complete. 6. Restart the OS. 3-4 The OneCommand Manager application GUI (in Windows)

23 Uninstalling OCM 1. Select Start Control Panel Programs Uninstall a Program 2. Select Emulex OCManager Enterprise version". 3. Click Remove or Uninstall. 4. The pop-up message "This will remove Emulex OCManager Enterprise from your computer. Do you want to continue?" is displayed. Click Yes to start uninstalling. 5. When uninstalling is complete, the pop-up message Emulex OCManager Enterprise has been removed from your computer. is displayed. Click OK. The OneCommand Manager application GUI (in Windows) 3-5

24 Confirming OCM version 1. Start OCM and click Help About OneCommand(TM) Manager to display the version. 2. Confirm that the version is listed in Table Click OK to close the window. 3-6 The OneCommand Manager application GUI (in Windows)

25 Starting OCM 1. Starting OCM. - Windows Server 2008 / Windows Server 2008 R2 : Select Start All programs Emulex OCManager. - Windows Server 2012 / Windows Server 2012 R2 : Select Start OCManager. - OCManager WebLaunch Install is not supported. Do not select this icon. - OCManager WebLaunch Uninstall is not supported. Do not select this icon. - OCManager WebLaunch Update URL is not supported. Do not select this icon. The OneCommand Manager application GUI (in Windows) 3-7

26 Stopping OCM 1. Stopping OCM. Select File Exit in menu bar or click the close box located in upper right corner in the window. 3-8 The OneCommand Manager application GUI (in Windows)

27 OCM functions OCM functions Main OCM functions are as follows. Table 3-4: Main Functions Explanation Remarks Viewing the configuration information Viewing the configuration information of host, adapters, ASIC, port, device, etc. Setting the adapter Setting the driver parameter, iscsi target and NPIV function. OCM Window Element Definitions The OCM window contains five basic components: the menu bar, the toolbar, the discovery-tree, the property tabs, and the status bar. (1) Main Window A B C D E A : Menu bar The commands : File, Edit, View, Port, Discovery, Batch, Help are located in the menu bar. Many of the menu bar commands are also available from the toolbar. B : Toolbar The OneCommand Manager application GUI (in Windows) 3-9

28 The buttons : Discovery Refresh, Reset, Host View, Fabric View, Virtual Ports View, Local HBAs Only, Show Host Groups, Find Host and search, Refresh LUNS, Help are located in the menu bar. Many of the toolbar functions are also available from the menu bar. C : Property Tabs The property tabs display configuration, statistical and status information for network elements. The set of available tabs is context-sensitive, depending on the type of network element or adapter port currently selected in the discovery-tree. D: Discovery-Tree The icons : local host, Other hosts, adapter, port, iscsi, FCoE, NIC, ASIC, Virtual port, COMSTAR, Target, LUN, Media Exchanger, Tape LUN, Target Controller, Switch are located in the discovery-tree (left pane). E : Status Bar The status bar displays messages about OCM functions, such as Discovery in progress or the progress when performing an Export SAN Info operation. (2) Commands in the menu bar - File menu Table 3-5: Command function Remarks Management Mode Configures Management Mode or TCP/IP Ver or later Management Mode Export SAN Info Creates reports about discovered SAN elements. Reports are generated in.xml and.csv format. Exit Quits OCM 3-10 The OneCommand Manager application GUI (in Windows)

29 - Edit menu Table 3-6: Command function Remarks Find Enables you to search by host name for a particular host in the discovery-tree. Find Next Continues searching for more instances of the name you specified. - View menu Table 3-7: Command function Remarks Tool bar The toolbar is visible by default. Use the Toolbar item in the View menu to hide the toolbar. If the item is checked, the toolbar is visible. Status Bar The status bar is visible by default. Use the Status Bar item in the View menu to hide the status bar. When checked, the status bar is visible. Group Adapter by Host Displays the discovery-tree by Host Name. Name Group Adapter by Fabric Displays the discovery-tree by Fabric Address. Address Group Adapter by Virtual Displays the discovery-tree by Virtual Port. Port Show Host Groups - Displays hosts by their associated groups. - Displays available host groups. Manage Host Groups... Configures the host groups iscsi Name Displays by iscsi name. iscsi Aliases Displays by iscsi Aliases. Expand/Collapse tree to Displays the discovery-tree expand expression by Group, Host/Fabric Adapters, Ports, PCI Function, VirtualPorts, or Targets. The OneCommand Manager application GUI (in Windows) 3-11

30 - Port menu Table 3-8: Command function Remarks Reset Port... Resets the specified port. Edit Name Not supported Use Default Name --- Not supported - Discovery menu Table 3-9: Command function Remarks Modify Settings Not supported Refresh Refreshes the device to be connected with. Refresh LUNs Refreshes the LUN to be connected with. This command is enabled when the Target icon is selected. TCP/IP --- Not supported - Batch menu Table 3-10: Command function Remarks Download Firmware Not supported Update Driver Parameter Not supported 3-12 The OneCommand Manager application GUI (in Windows)

31 - Help menu Table 3-11: Command function Remarks Contents Displays the OCM's online help. About OneCommand (TM) Displays the version information of OCM Manager (3) Toolbar Buttons The toolbar buttons perform the following tasks: Table 3-12: Button task Remarks Discovery Refresh button - Initiates a discovery refresh cycle. Reset button - Resets the selected adapter. Host View button (default) - Displays the host system. - Displays the installed adapters within each host system. - Displays adapter ports and the port numbers if available. - Displays adapters by the WWNN if multiple adapters have the same model number. - Displays the WWPN if targets are present. Multiple adapters can refer to the same target. - Displays the LUN number if LUNs are present. Fabric View button - Displays the FC/FCoE fabrics in the SAN with their fabric IDs. - Displays the ports under each switch. - If targets are present, displays each WWPN. Multiple adapters can refer to the same target. - If LUNs are present, displays each LUN number. - If the fabric ID is all zeros, no fabric is attached. Note: iscsi and NIC ports are not displayed in Fabric View. Virtual Ports View button - Displays virtual ports in the SAN. Note: iscsi and NIC ports are not displayed in Virtual Ports View. Local HBAs Only button - Displays only local adapters. Show Host Groups button and menu - Displays hosts by their associated groups. - Displays available host groups. The OneCommand Manager application GUI (in Windows) 3-13

32 Find Host button and search field - Enables you to search by host name for a particular host in the discoverytree. Refresh LUNS button - Initiates a LUN discovery refresh cycle. Help button - Displays the OCM's online help. - Displays the About OCM dialog box. The dialog box displays version information including; RMAPI, Discovery, DFClib, MILI Service Version, MILI Library Version and Remote Management Agent Version. (4) Discovery-Tree Icons Discovery-tree icons represent the following: Table 3-13: Icon Content Remarks The local host. Other hosts connected to the system. A green adapter icon with black descriptive text represents an online adapter. Blue text represents an adapter port that had previously been discovered, but currently is not being seen by the discovery engine (service). The adapter is removed from the discovery-tree if it still is not seen after the undiscovered adapter expiration time has elapsed (default is 1800 seconds, or 30 minutes). If the adapter is discovered again before the expiration time has elapsed, it reverts back to normal black text. The port icon represents an adapter port. A port icon with a red X indicates the link is down. Note: Multiport adapters are represented in the discovery-tree with separate port icons for each port with the port number displayed next to the icon. The iscsi icon represents an iscsi PCI function instance. iscsi functions can support up to sixteen logical adapters, with each logical adapter appearing in the discovery-tree as a separate child node under the respective iscsi function. The green iscsi icon represents an iscsi PCI function on-line instance. A black iscsi icon represents an iscsi PCI function port-disabled instance. A red iscsi icon represents an iscsi PCI function link down instance. The green FCoE icon represents an FCoE PCI function on-line instance. A black FCoE icon represents an FCoE PCI function port-disabled instance. A red FCoE icon represents an FCoE PCI function link down instance. The NIC icon represents a NIC-Only PCI function instance. A green icon indicates this function instance is on-line, black indicates it is disabled, and red indicates a link down instance. The ASIC node icon, only displayed for OneConnect dual ASIC 4 port 8Gb/s FC adapters, represents each ASIC on the adapter. Each ASIC is managed independently. The ASIC node format "ASIC bus#-sub-adapter#" represents the PCI bus number and the sub-adapter number, which is a concatenation of the discovered port numbers for the ASIC. For example, "ASIC 64-12" represents PCI bus number 64, and 12 represents ports 1 and 2. If there were no discovered functions for a port on that ASIC, the label would be "ASIC 64-2" (port 1 is missing) The OneCommand Manager application GUI (in Windows)

33 The Virtual Port icon represents a virtual port. The COMSTAR icon represents COMSTAR target mode ports. The Target icon represents connections to individual storage devices. Not supported The LUN icon represents connections to individual disk LUNs. The Media Exchanger icon represents connections to individual media exchangers. A media exchanger is a jukebox-like device that is capable of swapping various media device instances (such as records or CDs) in and out. The Tape LUN icon represents LUNs that are tape devices. The Target Controller LUN icon represents LUNs that are storage controllers. Not supported Not supported The Switch icon represents connections to the switch. Configuration Information (1) Host information There are two tabs that show host information: the Host Information tab and the Host Driver Parameters tab. The Host Information tab is read-only. The Host Driver Parameters tab enables you to view and define adapter driver settings for a specific host. 1. From View menu, click Group Adapters by Host Name. 2. Select a host in the discovery-tree. 3. Select a tab. The OneCommand Manager application GUI (in Windows) 3-15

34 - Host Information Tab The Host Information tab displays information for the selected host such as the number of adapters installed in the selected host and the number of fabrics to which it is connected. Table 3-14: Item Content Remarks Operating System The operating system and version installed on the selected host. Management IP Address If the host is discovered with FC, the Management IP Address field display "Host discovered over Fibre Channel" If the host has been added with TCP/IP access, the Management IP Address field displays the host's IP address, for example, "Local Host" is displayed if you selected the host you are actually launching from. Remote Manager Server Version Number of Adapters Number of Physical Ports NIC Functions FC Functions FCoE Functions FC Targets VPorts iscsi Functions iscsi Targets The version of the OCM server that is running on the host. If different versions of the OCM are installed on different hosts in the SAN, those differences appear in this field. The number of adapters installed in the host. The number of discovered physical ports that can be managed by this host. The number of NIC functions running on the discovered adapters on this host. The number of FC functions running on the discovered adapters on this host. The number of FCoE functions running on the discovered adapters on this host. The number of FC targets discovered on the FC/FCoE functions on this host. The number of discovered virtual ports that can be managed by this host. (Not supported on VMware ESX servers being managed through the CIM interface.) The number of iscsi functions running on the discovered adapters on this host. The number of iscsi targets discovered on the iscsi functions on this host The OneCommand Manager application GUI (in Windows)

35 - Host Driver Parameters Tab The Host Driver Parameters tab enables you to view and edit the adapter driver parameter settings contained in a specific host. The host driver parameters are global values and apply to all adapters in that host unless they are overridden by parameters assigned to a specific adapter using the adapter Driver Parameters tab. For each parameter, the tab shows the current value, the range of acceptable values, the default value, and whether the parameter is dynamic. Table 3-15: Item Content Remarks Installed Driver Type The current drivers installed on this host. Adapter Parameter A list of adapter driver parameters for the selected driver type and their current values. Modify Adapter Parameter Area Adapter-specific information is displayed in this area. This can include value, range, default, activation requirements and description. Value Enter a new value in the Value field in the same hexadecimal or decimal format as the current value or select a value from the drop-down menu. If you enter a value and the current value is in hexadecimal format, it is prefaced by "0x" (for example, 0x2d). You can enter a new hexadecimal value without the "0x". make all changes temporary (if possible) Restore Button Defaults Button Apply Button If you want the change to be temporary (causing the parameter to revert to its last permanent setting when the system is rebooted), check the Make change temporary box. This option is available only for dynamic parameters. If you changed driver parameters, but did not click Apply and you want to restore the parameters to their last saved values, click Restore. Click to reset all driver parameter values to their default (out-ofbox) values. Click to apply any driver parameter changes. If you changed a driver parameter that is not dynamic, you may need to reset the adapter port or create a new ramdisk and reboot the system. The OneCommand Manager application GUI (in Windows) 3-17

36 (2) Configuration information of onboard CNA / CNA expansion card / LAN expansion card The property tabs of "Adapter" icon are explained below. - Adapter Information Tab (for 2-port onboard CNA) Table : Item Content Remarks Model The model of the selected adapter. Serial Number The serial number of the selected adapter. Active Firmware The firmware version currently being used by the adapter. Version Firmware State The condition of the firmware. BIOS Version The version of the BIOS in use. HW Version The hardware version of the selected adapter. NCSI Version The Network Controller Sideband Interface version. IPL File Name The name of the IPL (Initial Program Load) file currently loaded. PCI Express Link The speed of the PCI bus in which the adapter running. Speed PCI Express Bus Width The number of lanes for the slot in which the adapter is running. Adapter Temperature If the adapter's temperature is not available, "Not Supported" is displayed. If supported by the adapter, this field displays the adapter's temperature and one of the following temperature-related status messages: - Normal: The adapter's temperature is within normal operational range. - Warning: The adapter's temperature is beyond normal operational range. If the temperature continues to increase, the adapter shuts down. You must determine the cause of the temperature problem and fix it immediately. - Exceeds operational range: The temperature has reached critical limit. You must determine the cause of the temperature problem and fix it before resuming operation The OneCommand Manager application GUI (in Windows)

37 Personality Area After the system overheating issue is resolved and the adapter has cooled down, reboot the system or, if the system supports hot swapping, cycle the power of the adapter slot. - Current : The current personality in use by the adapter. - After Reboot : (Not supported) - Apply button : (Not supported) License Features --- Not supported Personality - After Reboot configuration is not supported. See "Hitachi Compute Blade Emulex Adapters User's Guide for Hardware" for the personality change. - Adapter Information Tab (for 4-port onboard CNA) Table : Item Content Remarks Model The model of the selected adapter. Serial Number The serial number of the selected adapter. Active Firmware The firmware version currently being used by the adapter. Version Firmware State The condition of the firmware. BIOS Version The version of the BIOS in use. HW Version The hardware version of the selected adapter. NCSI Version The Network Controller Sideband Interface version. IPL File Name The name of the IPL (Initial Program Load) file currently loaded. PCI Express Link The speed of the PCI bus in which the adapter running. Speed PCI Express Bus Width The number of lanes for the slot in which the adapter is running. The OneCommand Manager application GUI (in Windows) 3-19

38 Adapter Temperature If the adapter's temperature is not available, "Not Supported" is displayed. If supported by the adapter, this field displays the adapter's temperature and one of the following temperature-related status messages: - Normal: The adapter's temperature is within normal operational range. - Warning: The adapter's temperature is beyond normal operational range. If the temperature continues to increase, the adapter shuts down. You must determine the cause of the temperature problem and fix it immediately. - Exceeds operational range: The temperature has reached critical limit. You must determine the cause of the temperature problem and fix it before resuming operation. After the system overheating issue is resolved and the adapter has cooled down, reboot the system or, if the system supports hot swapping, cycle the power of the adapter slot. - Adapter Information Tab (for CNA expansion card/lan expansion card) Table 3-17: Item Content Remarks Model The model of the selected adapter. Serial Number The serial number of the selected adapter. HW Version The hardware version of the selected adapter. ASICs The number of ASICs on the selected adapter. The information of CNA expansion card or LAN expansion card that corresponds to Adapter Information of onboard CNA is displayed in ASIC Information tab The OneCommand Manager application GUI (in Windows)

39 The property tabs of ASIC node icon are explained below. - ASIC Information Tab (for CNA expansion card / LAN expansion card) Table 3-18: Item Content Remarks Model The model of the selected adapter. Serial Number The serial number of the selected adapter. Active Firmware The firmware version currently being used by the adapter. Version Firmware State The condition of the firmware. BIOS Version The version of the BIOS in use. HW Version The hardware version of the selected adapter. NCSI Version The Network Controller Sideband Interface version. IPL File Name The name of the IPL (Initial Program Load) file currently loaded. PCI Express Link The speed of the PCI bus in which the adapter running. Speed PCI Express Bus Width The number of lanes for the slot in which the adapter is running. Adapter Temperature If the adapter's temperature is not available, "Not Supported" is displayed. If supported by the adapter, this field displays the adapter's temperature and one of the following temperature-related status messages: - Normal: The adapter's temperature is within normal operational range. - Warning: The adapter's temperature is beyond normal operational range. If the temperature continues to increase, the adapter shuts down. You must determine the cause of the temperature problem and fix it immediately. - Exceeds operational range: The temperature has reached critical limit. You must determine the cause of the temperature problem and fix it before resuming operation. After the system overheating issue is resolved and the adapter has cooled down, reboot the system or, if the system supports hot swapping, cycle the power of the adapter slot. The OneCommand Manager application GUI (in Windows) 3-21

40 Personality Area - Current : The current personality in use by the adapter. - After Reboot : (Not supported) - Apply button : (Not supported) License Features --- Not supported Personality - After Reboot configuration is not supported. See "Hitachi Compute Blade Emulex Adapters User's Guide for Hardware" for the personality change. - Firmware Tab Table : Item Content Remarks Active Firmware The firmware version currently being used by the adapter. Version Flash Firmware Version The flash firmware version currently being used by the adapter. BIOS Version The version of the BIOS currently being used by the adapter. Boot Code Versions The version of boot code and so on. Area Download Firmware Button --- Not supported Diagnostic Dump Button --- Not supported 3-22 The OneCommand Manager application GUI (in Windows)

41 - Firmware Tab (4-port onboard CNA) Table : Item Content Remarks Active Firmware The firmware version currently being used by the adapter. Version Flash Firmware Version The flash firmware version currently being used by the adapter. BIOS Version The version of the BIOS currently being used by the adapter. Boot Code Versions The version of boot code and so on. Area Download Firmware Button --- Not supported Diagnostic Dump Button --- Not supported The OneCommand Manager application GUI (in Windows) 3-23

42 - Adapter Configuration Tab (4-port onboard CNA) (Not supported) The property tabs of port icon are explained below. - Physical Port Info Tab Table 3-20: Item Content Remarks PCI Function Summary displays the number of logical ports of NIC/iSCSI/FCoE Area physical Port Status Area - Status : displays current connection status - Interface Type : 3-24 The OneCommand Manager application GUI (in Windows)

43 - Configured Speed : - DAC Cable Length : - Disable Port Button : When you disable a physical port, you disable all functions, such as iscsi and NIC, for the port. Disabled ports appear in the discovery-tree as a black port icon. Note: You cannot disable a port if PXE Boot is enabled or if any of the iscsi target sessions are boot sessions. - Set Speed Button : (Not supported) - DCB Tab Table 3-21: Item Content Remarks DCBX State The current DCBX (Data Center discovery and Capability exchange protocol) state (enabled or disabled). DCBX Mode The DCBX mode can be either DCB or CIN. Note: DCBX mode also configures FIP mode. If DCBX mode is DCB, FIP is enabled. If it is CIN, FIP is disabled. LLDP Transmit State DCBX uses Link Layer Discovery Protocol (LLDP) to exchange parameters between two link peers. For the DCBX protocol to operate correctly, both LLDP Rx and Tx must be enabled. If either Rx or Tx is disabled, DCBX is disabled. LLDP Receive State DCBX uses LLDP to exchange parameters between two link peers. For the DCBX protocol to operate correctly, both LLDP Rx and Tx must be enabled. If either Rx or Tx is disabled, DCBX is disabled. PFC Properties Area - State : Enabled means that flow control in both directions (Tx and Rx) is enabled. - Active Priority : Lists the priorities with PFC set to Enabled. - Sync'd : If yes, the PFC priorities have been set by the peer. This parameter cannot be set. - Error : The error state. This capability indicates whether an error has occurred during the configuration exchange with the peer.error is also set to YES when the Compatible method for the capability fails. The OneCommand Manager application GUI (in Windows) 3-25

44 FCoE Properties Area (FCoE ports only) iscsi Properties Area ETS Priority Group Properties Area - State : The FCoE state. It can be Enabled or Disabled. - Active Priorities : The current active priority assigned for FCoE. - Sync'd : If yes, the FCoE priority has been set by the peer. This parameter cannot be set. - Error : The FCoE error state. This capability indicates whether an error has occurred during the configuration exchange with the peer. Error is also set to YES when the Compatible method for the capability fails. - State : The iscsi state. It can be Enabled or Disabled. - Active Priorities : The current active priority assigned for iscsi. - Sync'd : If yes, the iscsi priority has been set by the peer. This parameter cannot be set. - Error : The iscsi error state. This capability indicates whether an error has occurred during the configuration exchange with the peer. Error is also set to YES when the Compatible method for the capability fails. - State : The FCoE or NIC-only state. It can be Enabled or Disabled. - Sync'd : If yes, the Priority Groups have been set by the peer. This parameter cannot be set. - Error : The error state. This capability indicates whether an error has occurred during the configuration exchange with the peer. Error is also set to YES when the Compatible method for the capability fails. Active Groups - PG : The Priority Group number. It can be 0 to 7. - Priorities : The priorities that are assigned to each Priority Group. It is represented in comma separated format. - Bandwidth % : The percentage of available link bandwidth allocated to a particular Priority Group. - Max Configurable PGs : This field indicates maximum number of priority groups that can be configured on the selected OneConnect adapter port. Configure DCB Button --- Not supported - Diagnostics Tab (Not supported) 3-26 The OneCommand Manager application GUI (in Windows)

45 - Transceiver Data Tab (Not supported) - Channel Management Tab (Not supported) Channel Management tab of "OneCommand Manager ver (or higher)" is not supported. See "Hitachi Compute Blade Emulex Adapters User's Guide for Hardware" - "4.1.3 MultiChannel configuration" to configure the BW(Bandwidth). The OneCommand Manager application GUI (in Windows) 3-27

46 The property tabs of NIC icon are explained below. - Port Information Tab Table 3-22: Item Content Remarks Driver Name The NIC driver file name. Driver Version The NIC driver version. MAC Address The NIC MAC address currently assigned to the port. Perm MAC Address The original factory assigned NIC MAC address. IPv4 Address The IPv4 address for the NIC port. Subnet Mask The subnet mask for the NIC port. Gateway Address The NIC initiator gateway address. Link Status The status of the link on the selected adapter port. Interface Name The interface assigned to this port by the host operating system. Port Speed The current port speed of the selected port. IPv6 Address The IPv6 address for the NIC port. Device ID The PCI device ID assigned to the NIC function. SubSys Device ID The PCI subsystem ID assigned to the NIC function. Vender ID The PCI vendor ID assigned to the NIC function. SubSys Vender ID The PCI subsystem vendor ID assigned to the NIC function. IP Address Origin The origin of the IP address (DHCP or Static). PCI Function The PCI function number assigned to the NIC function. PCI Bus Number The PCI BUS number assigned to the NIC function. Max MTU The maximum transmission unit for iscsi traffic. Current MTU The current transmission unit for iscsi traffic. Bandwidth Limit The QoS bandwidth restriction on the port. (Non vnic adapters only) Enable PXE Boot --- Not supported Enable PXE Boot function is not supported. See "Hitachi Compute Blade Emulex Adapters User's Guide for Hardware" for changing the PXE Boot configuration The OneCommand Manager application GUI (in Windows)

47 - PCI Registers Tab - VPD Tab PCI Registers Table 3-23: Item Content Remarks Product Name Product information about the selected adapter port. PN (Part Number) The adapter's part number. SN (Serial Number) The adapter's serial number. VO Vendor unique data. "V" indicates a vendor-specific field. An adapter may have none, one or more of these fields defined. Valid values for this field are "VO" (the letter "O", not the number zero) and "Vx" (where "x" is a number). The OneCommand Manager application GUI (in Windows) 3-29

48 The property tabs of iscsi icon are explained below. - Port Information Tab displayed in Ver or later Table 3-24: Item Content Remarks Driver Name The iscsi driver file name. Driver Version The iscsi driver version. MAC Address The iscsi MAC address currently assigned to the port. Perm MAC Address The original factory-assigned iscsi MAC address. Device ID The PCI device ID assigned to the iscsi function. Vender ID The PCI vendor ID assigned to the iscsi function. PCI Function The PCI function number assigned to the iscsi function. LDTO (Link Down Time Out) The amount of time in seconds that the iscsi driver delays reporting a link down error to the operating system. Max MTU Maximum transmission unit for iscsi traffic. Default ETO The default extended timeout. Max CDB Length Maximum SCSI command descriptor block size. SubSys Device ID The PCI subsystem ID assigned to the iscsi function. SubSys Vender ID The PCI subsystem vendor ID assigned to the iscsi function. PCI Bus Number The PCI bus number assigned to the iscsi function. TCP/IP Info Area - DHCP Enabled : The DHCP authentication status of the selected port. - IP Address : The iscsi initiator IP address. - Subnet Mask : The iscsi initiator subnet mask. - Gateway Address : The iscsi initiator gateway address. - VLAN Enabled : The VLAN enabled state for the iscsi interface. - VLAN ID : The VLAN identifier to use (only valid when VLAN is enabled). - 0 indicates the VLAN is disabled. - VLAN Priority : The VLAN priority for the iscsi interface. Modify... Button Enables you to change TCP/IP settings for the selected port. You can change the port's VLAN tag, priority, IP address and more. Network Info Area - Link Status : The status of the link on the selected adapter port. - Port Speed : The port speed at which the selected port is running. Enable iscsi Boot check box --- Not supported 3-30 The OneCommand Manager application GUI (in Windows)

49 Enable iscsi Boot function is not supported. See "Hitachi Compute Blade Emulex Adapters User's Guide for Hardware" for changing the iscsi Boot configuration. - PCI Registers Tab The OneCommand Manager application GUI (in Windows) 3-31

50 - isns Tab (Not supported) VPD Tab Table 3-25: Item Content Remarks Product Name Product information about the selected adapter port. PN (Part Number) The adapter's part number. SN (Serial Number) The adapter's serial number. VO Vendor unique data. "V" indicates a vendor-specific field. An adapter may have none, one or more of these fields defined. Valid values for this field are "VO" (the letter "O", not the number zero) and "Vx" (where "x" is a number) The OneCommand Manager application GUI (in Windows)

51 The property tabs of Virtual Port icon under iscsi icon are explained below. - iscsi Statistics Tab Table 3-26: Item Content Remarks Node Roles The node role for this iscsi initiator. Portal Count The number of rows in the iscsiportaltypetable which are currently associated with this iscsi instance. Node Count The number of rows in the iscsinodetypetable which are currently associated with this iscsi instance. Session Count The number of rows in the iscsisessiontypetable which are currently associated with this iscsi instance. Session Failure Count The number of times a session belonging to this port has failed. Last Session Failure The type of failure encountered in the last session failure. Type Last Session Remote The iscsi name of the remote node from the failed session. Node Name Session Digest Errors The count of sessions which failed due to receipt of a PDU containing header or data digest errors. Session Connection Timeout The count of sessions which failed due to a sequence exceeding a time limit. Session Format Errors The count of sessions which failed due to receipt of an iscsi PDU that contained a format error. Login Failures The number of times a login from this initiator failed. Last Failure Time The timestamp of the most recent failure of a login attempt from this initiator. A value of 0 indicates that no failures have occurred. Last Failure Type A description of the last failure. Last Target Failure Name The UTF-8 string name of the target that most recently failed a login request from this initiator. Last Target Failure Address The Internet Network Address of the target that most recently failed. Login Accept Responses The count of Login Response PDUs received by this initiator that were accepted. Login Other Fail Responses The count of Login Response PDUs received by this initiator with any status code not counted by the other objects. The OneCommand Manager application GUI (in Windows) 3-33

52 Login Redirect Response Login Authentication Fail Responses Login Authentication Failures Login Negotiation Failures Logout Normals Logout Others Port Row Status Portal Role Portal Protocol Portal Tag The count of Login Response PDUs received by the initiator with status class Redirection. The count of Login Response PDUs with status class 0x201 Authentication Failed received by this initiator. The number of times the initiator has aborted a login because the target could not be authenticated. The number of times the initiator has aborted a login because parameter negotiation with the target failed. The count of Logout Command PDUs generated by this initiator with reason code normal. The count of Logout Command PDUs generated by this initiator with any status code other than normal. This field allows entries to be dynamically added and removed from this table via Simple Network Management Protocol (SNMP). The role of a portal. A portal can operate in either one of two roles as a target portal and/or an initiator portal. The portal's transport protocol. The portal's aggregation tag when the portal is used as an initiator. - iscsi Initiator Login Options Tab Table 3-27: Item Content Remarks iscsi Names Area - Initiator iscsi Name : The iscsi qualifier name of the initiator. - Initiator Alias : An optional non-unique string used to identify the initiator. Initiator Login Options Area --- Not supported Authentication Area - Authentication Method : Three options are available for the Authentication method: "None", "One-Way CHAP" and "Mutual CHAP". One-Way CHAP requires only that the authenticator (iscsi target) authenticate the iscsi initiator. Mutual CHAP 3-34 The OneCommand Manager application GUI (in Windows)

53 Apply Changes Button View Default Login Options...Button requires that both the iscsi target and iscsi initiator authenticate each other. When "None" is selected, no authentication is performed. - Target CHAP Name : The iscsi login name sent by the initiator to the target for authentication. This parameter is required for both One-Way CHAP and Mutual CHAP authentication. The parameter is also known as the username. It can be any sequence of characters and numbers. The minimum length of the name is 1 character and the maximum length is 256 characters. - Target Secret : The iscsi login secret sent by the initiator to the target for authentication. This parameter is required for both One-Way CHAP and Mutual CHAP authentication. It can be any sequence of characters and numbers. The minimum length of the secret is 12 characters and maximum length is 16 characters. - Initiator CHAP Name : The iscsi login name sent by the target to the initiator for authentication. This parameter is only required for Mutual CHAP authentication. The parameter is also known as the username. It can be any sequence of characters and numbers. The minimum length of the name is 1 character and the maximum length is 256 characters. - Initiator Secret : The iscsi login secret sent by the target to the initiator for authentication. This parameter is only required for Mutual CHAP authentication. It can be any sequence of characters and numbers. The minimum length of the secret is 12 characters and the maximum length is 16 characters. Click this button to save and apply your changes. Click this button to see the default login settings. ImmediateData, HeaderDigest, DataDigest, Authentication Method functions are not supported. Use these functions in default configurations. The OneCommand Manager application GUI (in Windows) 3-35

54 - iscsi Target Discovery Tab Table 3-28: Item Content Remarks Target Portals The Target Portals table contains all target portals that are queried for targets. Depending on the SAN setup, the contents of this table may be a subset of the available target portals, or it could contain the full set of target portals for all iscsi targets. Add Portal Button Click to add a target portal. Remove Portal Button Click to remove a portal. Targets The Targets table contains all currently discovered targets. Targets in this table come from one of three possible sources: - The target was manually added. - The target was discovered via a target portal. - The target was found through an isns server query. Target Login... Button Click to log in to a selected target. Manually Add Target... Click to manually add an iscsi target. Button Target Sessions... Click to view active sessions for the selected target. Button Remove Target... Click to manually remove an iscsi target. Button Refresh Target Click to manually force a complete rediscovery of the targets, querying all configured isns servers and target portals The OneCommand Manager application GUI (in Windows)

55 The property tabs of Target icon under iscsi - Virtual Port icon are explained below. - Target Information Tab Table 3-29: Item Content Remarks Target iscsi Name The iscsi name assigned to the target. Target Alias The iscsi alias assigned to the target. This is assigned at the target portal, not by the OCM. ETO (Extended Timeout Value) The ETO for the target. The driver ensures that I/Os are not "timed out" until this time has expired (from the time the target stopped responding). You can change this value if you want. Target Portal Information Area - IP Address : The IP address through which the initiator communicates with the target. - Port : The TCP port through which the initiator communicates with the target. - Group Tag : The tag of the group for which sub-groups must be refreshed. Sessions... button Click to view the currently active sessions for the target. Apply Button Click to save and apply your ETO changes. The OneCommand Manager application GUI (in Windows) 3-37

56 The property tabs of LUN icon under iscsi - Virtual Port Target icon are explained below. - LUN Information Tab Table 3-30: Item Content Remarks Vendor Name The name of the vendor of the LUN. Model Number The vendor's model number for the LUN. LUN Name The name of the LUN. (Available only on ESX platforms.) Serial Number The vendor's serial number for the LUN. Capacity The un-formatted size of the LUN. Block Size The size of a logical unit block in bytes The OneCommand Manager application GUI (in Windows)

57 (3) Configuration information of FC expansion card / CNA expansion card(fcoe mode) / onboard CNA(FCoE mode) The property tabs of Adapter icon are explained below. - Adapter Information Tab (FC expansion card) Table 3-31: Item Content Remarks Model The complete model name of the adapter. Serial Number The manufacturer's serial number for the selected adapter. Hardware Version For LightPulse adapters it displays the JEDEC ID. For OneConnect adapters it displays the board type and revision code. Device ID The default device ID for the selected adapter. (Not supported on VMware ESX servers being managed through the CIM interface.) Adapter Temperature If the adapter's temperature is not available, "Not Supported" is displayed. If supported by the adapter, this field displays the adapter's temperature and one of the following temperaturerelated status messages: - Normal : The adapter's temperature is within normal operational range. - Warning : The adapter's temperature is beyond normal operational range. If the temperature continues to increase, the adapter shuts down. You must determine the cause of the temperature problem and fix it immediately. - Exceeds operational range : Adapter stopped: The temperature has reached critical limit, forcing the adapter to shut down. You must determine the cause of the temperature problem and fix it before resuming operation. After the system overheating issue is resolved and the adapter has cooled down, reboot the system or, if the system supports hot swapping, cycle the power of the adapter slot. The OneCommand Manager application GUI (in Windows) 3-39

58 - Firmware Tab (FC expansion card) Table 3-32: Item Content Remarks Active Firmware Version The firmware version currently being used by the adapter. Flash Firmware Version The firmware version used by the adapter in next booting. Download Firmware - Not supported Diagnostic Dump - Not supported Download Firmware button is not supported. Diagnostic Dump button is not supported The OneCommand Manager application GUI (in Windows)

59 The property tabs of port icon are explained below. - Port Information Tab (FC expansion card) Table 3-33: Item Content Remarks Port Attributes Area - Port WWN : The Port World Wide Name of the adapter. - Node WWN : The Node World Wide Name of the selected adapter. - Fabric Name or Host Name : The Fabric Name field is displayed in Host view. This is a 64-bit worldwide unique identifier assigned to the fabric. The Host Name is displayed in Fabric view. The host name is the name of the host containing the adapter. (Not supported on VMware ESX servers being managed through the CIM interface.) - Boot Version : The version of boot code installed on the selected adapter port. If the boot code is disabled, the field displays "Disabled". - Port FC ID : The FC ID for the selected adapter port. - Driver Version : The version of the driver installed for the adapter. - Driver Name : The executable file image name for the driver as it appears in the Emulex driver download package. - Firmware Version : The version of Emulex firmware currently active on the adapter port. - Discovered Ports : The number of mapped and unmapped ports found during discovery by the Emulex adapter driver. The mapped ports are targets and the unmapped ports are nontargets such as switches or adapters. - Port Type : The FC type of the selected adapter's port. (Not available if the port link is down.) - OS Device Name : The platform-specific name by which the selected adapter is known to the operating system. (Not supported on VMware ESX servers being managed through the CIM interface.) - Symbolic Node Name : The FC name used to register the driver with the name server. - Supported Class of Service : A frame delivery scheme The OneCommand Manager application GUI (in Windows) 3-41

60 Port Status Area Enable/Disable Port Button Loop Map Table exhibiting a set of delivery characteristics and attributes. There are three classes of service.. Class 1 provides a dedicated connection between a pair of ports with confirmed delivery or notification of non-delivery.. Class 2 provides a frame switched service with confirmed delivery or notification of non-delivery.. Class 3 provides a frame switched service similar to Class 2 but without notification of frame delivery or non-delivery. - Supported FC4 Types : A 256-bit (8-word) map of the FC-4 protocol types supported by the port containing the selected adapter. - Link Status : The status of the link on the selected adapter port. - Port Speed : The current port speed of the selected adapter port. Click to enable or disable the selected FC port. The loop map shows the different ports present in the loop, and is present only if the port (adapter) is operating in loop mode. The simplest example would be to connect a JBOD directly to an adapter. When this is done, the port type is a private loop, and the loop map has an entry for the adapter, and one entry for each of the disks in the JBOD. (Not supported on VMware ESX servers being managed through the CIM interface.) - Port Information Tab (CNA expansion card / onboard CNA) Table 3-34: Item Content Remarks Port Attributes Area - Port WWN : The Port World Wide Name of the adapter. - Node WWN : The Node World Wide Name of the selected adapter. - Fabric Name or Host Name : The Fabric Name field is displayed in Host view. This is a 64-bit worldwide unique identifier assigned to the fabric. The Host Name is displayed in Fabric view. The host name is the name of the host containing 3-42 The OneCommand Manager application GUI (in Windows)

61 Port Status Area the adapter. - Boot Version : The version of boot code installed on the selected adapter port. If the boot code is disabled, the field displays "Disabled". - Port FC ID : The FCoE ID for the selected adapter port. - PCI Function : The PCI function number assigned by the system. - Driver Version : The version of the driver installed for the adapter. - Driver Name : The executable file image name for the driver as it appears in the Emulex driver download package. - Firmware Version : The version of Emulex firmware currently active on the adapter port. - Discovered Ports : The number of mapped and unmapped ports found during discovery by the Emulex adapter driver. The mapped ports are targets and the unmapped ports are nontargets such as switches or adapters. - Port Type : The current operational mode of the selected adapter's port. - Enable PFC Throttle checkbox : PFC throttle is enabled by default to prevent the loss of FCoE packets. Uncheck the box to disable PFC throttle. Note: The checkbox does not appear if the adapter does not support PFC throttle. - OS Device Name : The platform-specific name by which the selected adapter is known to the operating system. - Supported Class of Servic : A frame delivery scheme exhibiting a set of delivery characteristics and attributes. There are three classes of service.. Class 1 provides a dedicated connection between a pair of ports with confirmed delivery or notification of non-delivery.. Class 2 provides a frame switched service with confirmed delivery or notification of non-delivery.. Class 3 provides a frame switched service similar to Class 2 but without notification of frame delivery or non-delivery. - Supported FC4 Types : A 256-bit (8-word) map of the FC-4 protocol types supported by the port containing the selected adapter. - Link Status : The status of the link on the selected adapter port. - Port Speed : The current port speed of the selected adapter port. - Bandwidth Limit : The QoS bandwidth restriction on the port. The OneCommand Manager application GUI (in Windows) 3-43

62 - Statistics Tab (FC/FCoE) Table 3-35: Item Content Remarks Tx Frames FC frames transmitted by this adapter port. Tx Words FC words transmitted by this adapter port. Tx KB Count FC kilobytes transmitted by this adapter port. Tx Sequences FC sequences transmitted by this adapter port. LIP count The number of loop initialization primitive (LIP) events that have occurred for the port. This field is not supported if the topology is not arbitrated loop. Loop initialization consists of the following: - Temporarily suspending loop operations. - Determining whether loop capable ports are connected to the loop. - Assigning AL_PA IDs. - Providing notification of configuration changes and loop failures. - Placing loop ports in the monitoring state. Error Frames The number of frames received with cyclic redundancy check (CRC) errors. Link Failures The number of times the link has failed. A link failure is a possible cause of a timeout. Loss of Signal The number of times the signal was lost. Invalid Tx Words The total number of invalid words transmitted by this adapter port. Ex Count Orig The number of FC exchanges originating on this port. (Not supported on VMware ESX servers being managed through the CIM interface.) Active XRIs The number of active exchange resource indicators. (Not supported on VMware based ESX platforms using the CIM interface.) Received P_BSY The number of FC port-busy link response frames received. Link Transitions The number of times the SLI port sent a link attention condition. Elastic Buf Overruns The number of times the link interface has had its elastic buffer overrun. Rx Frames The number of FC frames received by this adapter port The OneCommand Manager application GUI (in Windows)

63 Rx Words Rx KB Count Rx Sequences NOS count Dumped Frames Loss of Sync Prim Seq Prot Errs Invalid CRCs Ex Count Resp Active RPIs Receive F_BSY Primitive Seq Timeouts Arbitration Timeouts The number of FC words received by this adapter port. The received kilobyte count by this adapter port. The number of FC sequences received by this adapter port. (Not supported on VMware ESX servers being managed through the CIM interface.) The number of NOS events that have occurred on the switched fabric. (Not currently supported for Emulex Windows drivers or arbitrated loop.) The number of frames that were lost due to a lack of host buffers available. (Not currently supported for the SCSIport Miniport driver, the Storport Miniport driver or the driver for Solaris.) The number of times loss of synchronization has occurred. The primitive sequence protocol error count. This counter is incremented whenever there is any type of protocol error. The number of frames received that contain CRC failures. The number of FC exchange responses made by this port. (Not supported on VMware ESX servers being managed through the CIM interface.) The number of remote port indicators. (Not supported on VMware ESX servers being managed through the CIM interface.) The number of FC port-busy link response frames received. The number of times a primitive sequence event timed out. (Not supported on VMware ESX servers being managed through the CIM interface.) The number of times the arbitration loop has timed out.large counts could indicate a malfunction somewhere in the loop or heavy usage of the loop. (Not supported on VMware ESX servers being managed through the CIM interface.) The OneCommand Manager application GUI (in Windows) 3-45

64 - Maintenance Tab (8Gb FC expansion card) Table 3-36: Item Content Remarks Firmware Area - Current Version : The Emulex firmware version number for this model of adapter. - Initial Load : The firmware version stub responsible for installing SLI code into its proper slot. - SLI-2 Name : The name of the SLI-2 firmware overlay. - Kernel Version : The version of the firmware responsible for starting the driver. - Operational Name : The name of the operational firmware for the selected adapter. - SLI-1 Name : The name of the SLI-1 firmware overlay. - SLI-3 Name : The name of the SLI-3 firmware overlay. - Adapter Boot Version : Displays one of the following:. The selected adapter port's boot code version if boot code is present.. "Disabled" if the boot code is disabled.. "Not Present" if boot code is not loaded. If boot code is not loaded, the Enable Adapter boot checkbox is not visible and you cannot configure the selected port to boot from SAN. Enable adapter boot checkbox Not supported Download Firmware... Button Not supported Configure Boot... Button Not supported WWN Management Area --- Not supported Change WWN... Button Not supported Download Firmware... button is not supported The OneCommand Manager application GUI (in Windows)

65 - Maintenance Tab (FCoE) Table 3-37: Item Content Remarks Firmware Area - Firmware Version on Flash : Specifies the firmware version stored on the adapter's non-volatile storage. When the system restarts, this version becomes the active firmware version. - Service Processor FW Version : Specifies the firmware version that is currently operational on the adapter. - Active Firmware Version : The version of firmware running on the selected adapter. - ULP FW Name : The firmware version running on the (Upper Layer Protocol) processors within the ASIC. Configure Boot... Button Not supported WWN Management Area --- Not supported Change WWN... Button Not supported The OneCommand Manager application GUI (in Windows) 3-47

66 - Maintenance Tab (16Gb FC expansion card) Table 3-38: Item Content Remarks Firmware Area - Active Firmware Version : The version of firmware running on the selected adapter. - Service Processor FW Version : Specifies the firmware version that is currently operational on the adapter. - Firmware Version on Flash : Specifies the firmware version stored on the adapter's non-volatile storage. When the system restarts, this version becomes the active firmware version. - ULP FW Name : The firmware version running on the (Upper Layer Protocol) processors within the ASIC. - Adapter Boot Version : Displays one of the following:. The selected adapter port's boot code version if boot code is present.. "Disabled" if the boot code is disabled.. "Not Present" if boot code is not loaded. If boot code is not loaded, the Enable Adapter boot checkbox is not visible and you cannot configure the selected port to boot from SAN. Configure Boot... Button Not supported WWN Management Area --- Not supported Change WWN... Button Not supported 3-48 The OneCommand Manager application GUI (in Windows)

67 - DHCHAP Tab (Not supported) - Target Mapping Tab (FC/FCoE) Table 3-39: Item Content Remarks Current Settings Area - Active Bind Type : WWPN, WWNN, or a destination identifier (D_ID). - Automapping : The current state of SCSI device automapping: enabled (default) or disabled. Current Mappings Area This table lists current mapping information for the selected adapter port. Persistent Binding Configuration Area This table lists persistent binding information for the selected adapter port. (Not available on VMware ESX servers being managed through the CIM interface.) Display Mode Radio Buttons Refresh Button Change Settings Button Show WWPN, Show WWNN or Show D_ID options enable you to choose how to display information in the Persistent Binding Configuration table. Click to refresh the Target Mapping tab. Click to enable or disable automapping, choose a bind type and enable or disable LUN mapping and unmasking. (Not available on VMware ESX servers being managed through the CIM interface.) Not supported Add Binding Button Click to add a persistent binding. Not supported Bind New Target Button Click to add a target that does not appear in the Persistent Binding table. Not supported Remove Button Click to remove the selected binding. Remove All Bindings Button Click to remove all persistent bindings that are displayed. The OneCommand Manager application GUI (in Windows) 3-49

68 - Driver Parameters Tab (FC/FCoE) Table 3-40: Item Content Remarks Installed Driver Type The current drivers installed on this host. If there is more than one driver type installed, the Installed Driver Types drop-down menu shows a list of all driver types that are installed on the adapters in the host and enables you to select the particular driver type to configure. Adapter Parameter table A list of adapter driver parameters for the selected driver type and their current values. Modify Adapter Parameter Area Adapter-specific information is displayed in this area. This can include value, range, default, activation requirements and description. Make all changes temporary check Box Restore Button Default Button Globals Button Apply Button Save Button If you are making changes to multiple parameters, and you want all the changes to be temporary, check the Make all changes temporary box. This setting overrides the setting of the Make change temporary box. Only dynamic parameters can be made temporary. If you changed driver parameters, but did not click Apply and you want to restore the parameters to their last saved values, click Restore. Click to reset all driver parameter values to their default (outof-box) values. Click to apply any driver parameter changes. If you changed a driver parameter that is not dynamic, you may need to reset the adapter port or create a new ramdisk and reboot the system The OneCommand Manager application GUI (in Windows)

69 - Diagnostics Tab Table 3-41: Item Content Remarks Diagnostic Test --- Not supported Beacon --- Not supported Diagnostic Dump... button --- Not supported PCI Registers Flash Contents - Transceiver Data Tab (Not supported) The OneCommand Manager application GUI (in Windows) 3-51

70 - VPD Tab Table 3-42: Item Content Remarks Product Name Product information about the selected adapter port. PN (Part Number) The adapter's part number. SN (Serial Number) The adapter's serial number. VO Vendor unique data. "V" indicates a vendor-specific field. An adapter may have none, one or more of these fields defined. Valid values for this field are "VO" (the letter "O", not the number zero) and "Vx" (where "x" is a number) The OneCommand Manager application GUI (in Windows)

71 The property tabs of Target icon under Adapter - Port icon are explained below. - Target Information Tab Table 3-43: Item Content Remarks Mapping Information Area - FC ID : The FC ID for the target; assigned automatically in the firmware. - SCSI Bus Number : The SCSI bus number to which the target is mapped. - SCSI Target Number : The target's identifier on the SCSI bus. - Node WWN : A unique 64-bit number, in hexadecimal, for the target (N_PORT or NL_PORT). - Port WWN : A unique 64-bit number, in hexadecimal, for the fabric (F_PORT or Switched Fabric Loop Port [FL_PORT]). - OS Device Name : The operating system device name. The OneCommand Manager application GUI (in Windows) 3-53

72 - LUN Masking Tab (In disabled state) Table 3-44: Item Content Remarks Re-enable LUN enables LUN masking again. masking Button 3-54 The OneCommand Manager application GUI (in Windows)

73 - LUN Masking Tab (In enabled state) Table 3-45: Item Content Remarks LUN The FC LUN number. On Reboot The 'On Reboot' column shows the mask configuration currently saved to the configuration file on disk (Solaris) or to the Registry (Windows). Normally, for a specific LUN, the states reported in the 'On Reboot' and 'Current' column are identical. However, there can be times where these do not match. For example, the hbacmd utility can be used to change only the 'Current' mask state for a LUN and not touch the 'On Reboot' mask state contained in the configuration file. Current The 'Current' column displays the live mask state currently in use by the driver. When you first see the LUN Masking tab, the mask states displayed in the 'Current' column are identical to the mask states for the corresponding LUNs in the discoverytree. The OneCommand Manager application GUI (in Windows) 3-55

74 The property tabs of LUN icon under Adapter - Port Target icon are explained below. - LUN Information Tab Table 3-46: Item Content Remarks Vendor/Product Information Area - Vendor Name : The name of the vendor of the LUN. - Product ID : The vendor-specific ID for the LUN. - Revision : The vendor-specific revision number for the LUN. Mapping Information Area LUN Capacity Area LUN Masking Information Area - FCP LUN : The FC identifier used by the adapter to map to the SCSI OS LUN. - SCSI OS LUN : The SCSI identifier used by the OS to map to the specific LUN. - OS Device Name : The name assigned by the OS to the LUN. Note: LUN capacity information is only provided when the LUN is a mass-storage (disk) device. Other devices like tapes and scanners, etc. do not display capacity. - Capacity : The capacity of the LUN, in megabytes. - Block Size : The length of a logical unit block in bytes. - Current Mask Status : Possible states are masked or unmasked The OneCommand Manager application GUI (in Windows)

75 Configuring by OCM Configuring the Personality Configuring the personality of onboard CNA or CNA expansion card by the OCM is not supported. See "Hitachi Compute Blade Emulex Adapter User's Guide for Hardware" for configuring the personality. Configuring the PXE Boot Configuring the PXE by OCM is not supported. See "Hitachi Compute Blade Emulex Adapter User's Guide for Hardware" for configuring the PXE. Configuring UEFI on the system is necessary for the PXE Boot. See "EFI User's Guide" for the PXE boot Driver Parameter Settings The driver parameter can be set by the OCM. Setting the parameter Queue Depth of "exlfc" driver which is the driver of the FC expansion card is explained below. The performance may be improved by changing the setting of Queue Depth. 1. Start the OCM. Windows Server 2008 / Windows Server 2008 R2 : Select Start All programs Emulex OCManager. Windows Server 2012 / Windows Server 2012 R2 : Select Start OCManager. 2. (a) Select LPe1205A-HI Port in the discovery-tree. (b) Open Driver Parameters tab. (c) Select Queue Depth in Adapter Driver list. (d) Input a value in Value field (e) Click Apply button. (b) (d) (a) (c) (e) The OneCommand Manager application GUI (in Windows) 3-57

76 3. The message Are you sure you want to save these new drivers parameter settings? is popped-up. Click Yes 4. The message The specified changes have been made. is popped-up. 5. Reboot the system. The setting value of Queue Depth : The performance may be improved by changing the setting of Queue Depth. The value is limited as follows. The number of LUN to be accessed * Queue_Depth must be less than 512. (Queue Depth = 1 ~ 32) LUN is 17 for example: - When Queue Depth is 32 : 17 * 32 = 544 : NG (larger than 512) - When Queue Depth = 31 : 17 * 31 = 527 : NG (larger than 512) - When Queue Depth = 31 : 17 * 30 = 510 : OK (less than 512) If you need to reset the value to the default, click Defaults button and Apply button and then reboot the system. iscsi Target Settings (1) Connecting to iscsi Target Connecting to or disconnecting the iscsi target can be set by the OCM. The procedure for CNA expansion card for example is explained below. 1. Start OCM. - Windows Server 2008 / Windows Server 2008 R2 : Select Start All programs Emulex OCManager. - Windows Server 2012 / Windows Server 2012 R2 : Select Start OCManager. 2. Set the IP Address of the iscsi initiator. (a) Select OCxxxxxxxxx-xx-HI - ASIC xx-x - Port- iscsi in the discovery-tree. (b) Open Port Information tab. (c) Click Modify button The OneCommand Manager application GUI (in Windows)

77 (b) (a) (c) 3. Modify TCP/IP Configuration window is displayed. Input the values to IP Address field and Subnet Mask field, and click OK - VLAN function is not supported. Do not check VLAN Enabled check box. See " Hitachi Compute Blade LAN Advanced Function Manual for Emulex" for VLAN setting. - DHCP function is not supported. Do not check DHCP Enabled check box. - Do not enter any value to Gateway Address field. The OneCommand Manager application GUI (in Windows) 3-59

78 4. Confirm the value in the TCP/IP Info area to be set to the inputted value. 5. Set the iscsi initiator name. (a) Select OCxxxxxxxxx-xx-HI - ASIC xx-x - Port- iscsi Virtual Port icon in the discovery-tree. (b) Open the iscsi Initiator Login Options tab. (c) Input to Initiator iscsi Name field. (d) Click Apply Changes button. (b) (c) (a) (d) Apply Changes - Immediate Data, Header Digest, Data Digest, Authentication Method are not supported. Use the default values The OneCommand Manager application GUI (in Windows)

79 6. Connect to the iscsi target (a) Select OCxxxxxxxxx-xx-HI - ASIC xx-x - Port- iscsi Virtual Port icon in the discovery-tree. (b) Open iscsi Target Discovery tab. (c) Click Add Portal button. (b) (a) (c) 7. Input the IP Address of iscsi disk array to be connected to. (a) Input the IP address to the Portal Address field. (b) Click OK. (a) (b) 8. When the IP address is correct, the message Success adding send target portal. is displayed. The OneCommand Manager application GUI (in Windows) 3-61

80 9. Login to the target. (a) Select iscsi Name of the iscsi disk array to be connected. (b) Click Target Login button. (a) (b) 10. Target Login window is displayed, and click OK The OneCommand Manager application GUI (in Windows)

81 11. Confirm that the value in Status column changes to Connected. 12. Confirm that the target has been connected to. (a) Confirm that the Target icon and LUN icon are added under the Virtual Port icon in the discovery-tree. (b) Confirm the values in Target iscsi Name field and IP Address in Target Information tab. And the procedure is complete. (b) (a) The OneCommand Manager application GUI (in Windows) 3-63

82 (2) Disconnecting the iscsi target The procedure to disconnect the iscsi target is described below. 1. Select the iscsi target to be disconnected. (a) Select OCxxxxxxxxx-xx-HI - ASIC xx-x - Port- iscsi Virtual Port icon in the discovery-tree. (b) Open iscsi Target Discovery tab. (c) Select the target to be disconnected in the Target area. (d) Click Target Sessions button. (b) (a) (c) (d) 2. Target Sessions window is displayed, and click Logout. 3. Target Logout Warning popped up window is displayed, and click Yes. 4. Confirm that the value in the Status column changes to Unconnected. And the procedure is complete The OneCommand Manager application GUI (in Windows)

83 NPIV Settings (1) Conditions to use NPIV (N_Port ID Virtualization) function is supported for FC expansion card in Windows Server 2012 / Windows Server 2012 R2 environment. The following conditions are required to use NPIV. Table 3-47: 8Gb FC expansion card FC Firmware ver. 2.01A12 or higher. Driver ver (Windows 2012) or higher Driver ver (Windows 2012 R2) or higher OneCommand / Manager ver. or higher 16Gb FC expansion card or higher or higher or higher / or higher (2) Setting procedure Set Enabled to EnableNPIV item to use NPIV. 1. Start OCM. - Windows Server 2012 / Windows Server 2012 R2 : Select Start OCManager. The OneCommand Manager application GUI (in Windows) 3-65

84 2. Select the port Port x: xx:xx:xx:xx:xx:xx: xx:xx of the FC adaper LPe12xxxxx to configure, and select Driver Parameters tab. 3. Move the cursor to EnableNPIV in Adapter Parameter column, and select Enabled The OneCommand Manager application GUI (in Windows)

85 4. Press Apply button on the bottom of the window. 5. Select Yes for the message Are you sure you want to save these new driver parameter settings? in the Driver Parameter Configuration window. 6. Press OK for the message The specified changes have been made. One or more of your changes require a reboot before they become active. in the Driver Parameter Configuration window. If the NPIV settings are required for other ports or adapters, repeat the step 2 to step Reboot the OS and the system. - To enable the NPIV function, the configurations in OS like the virtual SAN manager setting on the Hyper-V manager on Windows 2012 or Windows 2012 R2 are also required other than this setting by OCM. - When connecting to the disk array equipment via FC switch, the FC switch has to support the NPIV protocol. - Link up the NPIV port of the virtual machine or the virtual machine may fail to boot up. - To enable the security function of disk array equipment (Hostgroup setting, LUN security setting etc.) per NPIV port, the WWN that is assigned to NPIV port has to be registered. The OneCommand Manager application GUI (in Windows) 3-67

86

87 4 The OneCommand Manager application CLI (in Linux) This chapter describes the OneCommand Manger application CLI (OCM_CLI hereafter) for Emulex adapters. OCM CLI version List OCM CLI version ListInstalling OCM CLI Uninstalling OCM CLI Confirming OCM CLI version Starting OCM CLI Stopping OCM CLI OCM CLI functions Configuring by OCM CLI The OneCommand Manager application CLI (in Linux) 4-1

88 OCM_CLI version List Supported OCM_CLI versions are as follows. Table 4-1 : No. Supported OCM_CLI version Remarks Initial release or Only for : CB500 CB520X B1 CB500 CB520X B2 CB500 CB520H B3 CB2500 CB520X B1 CB2500 CB520X B2 CB2500 CB520H B3 Only for RHEL6.6 (except CB500 CB520AA1) Only for RHEL6.5 and later Only for : CB500 CB520H x2 CB500 CB520X B1 CB500 CB520X B2 CB500 CB520H B3 CB500 CB520H B4 CB2500 CB520X B1 CB2500 CB520X B2 CB2500 CB520H B3 Only for RHEL The OneCommand Manager application CLI (in Linux)

89 Installing OCM_CLI This section describes the OCM_CLI installation procedure. The following description assumes that user logs on with administrator privilege (such as root). The OCM_CLI has been installed to the OS preinstalled system with onboard CNA, CNA expansion card or LAN expansion card. Install OCM_CLI when reinstalling OS or installing the Emulex adapters newly to the system. The drivers and OCM_CLI are provided with CD media : "Server installation and monitoring tool" or " 10Gb CNA Driver CD". 1. Confirm the OCM_CLI version. Execute the following command and see the value of "Command Line Interface" column. # hbacmd Version Confirm that the version is listed in Table 4-1. When the version is supported, the installation is not necessary. When upgrading or downgrading, go to next step. When reinstalling, go to next step after uninstalling. The uninstalling process is describes in the section "Uninstalling OCM_CLI". 2. Insert "Server installation and monitoring tool" or "10Gb CNA Driver CD" media into the DVD-ROM drive of system console. For CB500/CB2500: Select Tools - Launch Virtual Media located in upper side of Remote Console menu and open Virtual Media Session window. Check the Mapped check box of the CD/DVD drive to set the virtual drive. For CB2000: Select Remote CD/DVD - Start CD/DVD in the tool bar of the remote console. Then, select CD/DVD Drive button and click OK. (See "Hitachi Compute Blade 2000 USER'S GUIDE" for Remote Console Application (Java Application).) Table 4-2: - CB500 CB520A A1 model : "CB500 10Gb CNA Driver CD ver (or higher)" media : OS OCM_CLI version Location of the installation file RHEL6.2/5.7/ /RHEL6/Utility/elxocm06*-<version>.tgz RHEL ("*" is a number.) RHEL /RHEL6u5/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL6.6/6.7 Not supported - RHEL7.1 Not supported - RHEL7.2 Not supported - The OneCommand Manager application CLI (in Linux) 4-3

90 - CB500 CB520H x1/cb540a x1 model : "CB500 10Gb CNA Driver CD ver.01-13(or higher)" media : OS OCM_CLI version Location of the installation file RHEL6.2/5.7/ /RHEL6/Utility/elxocm06*-<version>.tgz RHEL ("*" is a number.) RHEL /RHEL6u5/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL6.7 Not supported - RHEL7.1 Not supported - RHEL7.2 Not supported - - CB500 CB520H B2 model: "CB500 10Gb CNA Driver CD ver.01-22(or higher)" media : OS OCM_CLI version Location of the installation file RHEL /RHEL6/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL or /RHEL6u5/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL or /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL6.7 Not supported - RHEL /RHEL7u1/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL7u2/Utility/elxocm06*-<version>.tgz ("*" is a number) - CB500 CB520X B1/CB520H B3 model: "CB500 10Gb CNA Driver CD ver.01-22(or higher)" media : OS OCM_CLI version Location of the installation file RHEL or /RHEL6u5/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL or /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL6.7 Not supported - RHEL /RHEL7u1/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL7u2/Utility/elxocm06*-<version>.tgz ("*" is a number) - CB500 CB520X B2 model: "CB500 10Gb CNA Driver CD ver (or higher)" media : OS OCM_CLI version Location of the installation file RHEL or /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL6.7 Not supported - RHEL /RHEL7u1/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL7u2/Utility/elxocm06*-<version>.tgz ("*" is a number) - CB500 CB520H B4 model: "CB500 10Gb CNA Driver CD ver (or higher)" media : OS OCM_CLI version Location of the installation file RHEL /RHEL6u7/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL7u2/Utility/elxocm06*-<version>.tgz ("*" is a number) 4-4 The OneCommand Manager application CLI (in Linux)

91 - CB2500 CB520X B1/CB520H B3 model: "CB Gb CNA Driver CD ver (or higher)" media : OS OCM_CLI version Location of the installation file RHEL or /RHEL6u5/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL or /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL6.7 Not supported - RHEL /RHEL7u1/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL7u2/Utility/elxocm06*-<version>.tgz ("*" is a number) - CB2500 CB520X B2 model: "CB Gb CNA Driver CD ver (or higher)" media : OS OCM_CLI version Location of the installation file RHEL or /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL6.7 Not supported - RHEL /RHEL7u1/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL7u2/Utility/elxocm06*-<version>.tgz ("*" is a number) - CB2500 CB520H B4 model: "CB Gb CNA Driver CD ver (or higher)" media : OS OCM_CLI version Location of the installation file RHEL /RHEL7u2/Utility/elxocm06*-<version>.tgz ("*" is a number) - CB2000 High performance server blade x2, Standard server blade x3 model : "CB Gb CNA Driver CD ver (or higher)" media : OS OCM_CLI version Location of the installation file RHEL6.2/5.7/ /RHEL6/Utility/elxocm06*-<version>.tgz RHEL ("*" is a number.) RHEL /RHEL6u5/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL6.7 Not supported - RHEL7.1 Not supported - RHEL7.2 Not supported - - CB2000 Standard server blade x4 model: "CB Gb CNA Driver CD ver (or higher)" media : OS OCM_CLI version Location of the installation file RHEL6.2/5.7/ /RHEL6/Utility/elxocm06*-<version>.tgz RHEL ("*" is a number.) RHEL /RHEL6u5/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL6.7 Not supported - RHEL7.1 Not supported - RHEL7.2 Not supported - Mount the media to any directory in the system. # mount /dev/cdrom /media Copy the utility file from the mounted media to the directory in the system. The directory in the system is /tmp/ocmwork/ for example. # mkdir /tmp/ocmwork # cp a /media/<path to the install file>/elxocm<version>.tgz /tmp/ocmwork # umount /media # cd /tmp/ocmwork The OneCommand Manager application CLI (in Linux) 4-5

92 Extract the utility file. # tar -zxvf /tmp/ocmwork/elxocm<version>.tgz 3. Execute the following command. # chmod 755 install.sh #./install.sh -q 4. Reboot the system and the procedure is complete. 4-6 The OneCommand Manager application CLI (in Linux)

93 Uninstalling OCM_CLI 1. Confirm the OCM_CLI version. Execute the following command and see the value of "Command Line Interface" column. # hbacmd Version Confirm that the version is listed in Table Insert "Server installation and monitoring tool" or "10Gb CNA Driver CD" media into the DVD-ROM drive of system console. For CB500/CB2500: Select Tools - Launch Virtual Media located in upper side of Remote Console menu and open Virtual Media Session window. Check the Mapped check box of the CD/DVD drive to set the virtual drive. For CB2000: Select Remote CD/DVD - Start CD/DVD in the tool bar of the remote console. Then, select CD/DVD Drive button and click OK. (See "Hitachi Compute Blade 2000 USER'S GUIDE" for Remote Console Application (Java Application).) Table 4-3: - CB500 CB520A A1 model : "CB500 10Gb CNA Driver CD ver (or higher)" media : OS OCM_CLI version Location of the installation file RHEL6.2/5.7/ /RHEL6/Utility/elxocm06*-<version>.tgz RHEL ("*" is a number.) RHEL /RHEL6u5/Utility/elxocm06*-<version>.tgz ("*" is a number.) - CB500 CB520H x1/cb540a x1 model : "CB500 10Gb CNA Driver CD ver.01-13(or higher)" media : OS OCM_CLI version Location of the installation file RHEL6.2/5.7/ /RHEL6/Utility/elxocm06*-<version>.tgz RHEL ("*" is a number.) RHEL /RHEL6u5/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) - CB500 CB520H B2 model: "CB500 10Gb CNA Driver CD ver.01-22(or higher)" media : OS OCM_CLI version Location of the installation file RHEL /RHEL6/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL or /RHEL6u5/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL or /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL7u1/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL7u2/Utility/elxocm06*-<version>.tgz ("*" is a number) The OneCommand Manager application CLI (in Linux) 4-7

94 - CB500 CB520X B1/CB520H B3 model: "CB500 10Gb CNA Driver CD ver.01-22(or higher)" media : OS OCM_CLI version Location of the installation file RHEL or /RHEL6u5/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL or /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL7u1/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL7u2/Utility/elxocm06*-<version>.tgz ("*" is a number) - CB500 CB520X B2 model: "CB500 10Gb CNA Driver CD ver (or higher)" media : OS OCM_CLI version Location of the installation file RHEL /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL7u1/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL7u2/Utility/elxocm06*-<version>.tgz ("*" is a number) - CB500 CB520H B4 model: "CB500 10Gb CNA Driver CD ver.01-22(or higher)" media : OS OCM_CLI version Location of the installation file RHEL /RHEL6u7/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL7u2/Utility/elxocm06*-<version>.tgz ("*" is a number) - CB2500 CB520X B1/CB520H B3 model: "CB Gb CNA Driver CD ver (or higher)" media : OS OCM_CLI version Location of the installation file RHEL or /RHEL6u5/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL or /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL7u1/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL7u2/Utility/elxocm06*-<version>.tgz ("*" is a number) - CB2500 CB520X B2 model: "CB Gb CNA Driver CD ver (or higher)" media : OS OCM_CLI version Location of the installation file RHEL /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL RHEL /RHEL7u1/Utility/elxocm06*-<version>.tgz ("*" is a number.) /RHEL7u2/Utility/elxocm06*-<version>.tgz ("*" is a number) - CB2500 CB520H B4 model: "CB Gb CNA Driver CD ver (or higher)" media : OS OCM_CLI version Location of the installation file RHEL /RHEL7u2/Utility/elxocm06*-<version>.tgz ("*" is a number) - CB2000 High performance server blade x2, Standard server blade x3 model : "CB Gb CNA Driver CD ver (or higher)" media : OS OCM_CLI version Location of the installation file RHEL6.2/5.7/ /RHEL6/Utility/elxocm06*-<version>.tgz RHEL ("*" is a number.) RHEL /RHEL6u5/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) 4-8 The OneCommand Manager application CLI (in Linux)

95 - CB2000 Standard server blade x4 model: "CB Gb CNA Driver CD ver (or higher)" media : OS OCM_CLI version Location of the installation file RHEL6.2/5.7/ /RHEL6/Utility/elxocm06*-<version>.tgz RHEL ("*" is a number.) RHEL /RHEL6u5/Utility/elxocm06*-<version>.tgz ("*" is a number.) RHEL /RHEL6u6/Utility/elxocm06*-<version>.tgz ("*" is a number.) Mount the media to any directory in the system. # mount /dev/cdrom /media Copy the utility file from the mounted media to the directory in the system. The directory in the system is /tmp/ocmwork/ for example. # mkdir /tmp/ocmwork # cp a /media/<path to the install file>/elxocm<version>.tgz /tmp/ocmwork # umount /media # cd /tmp/ocmwork Extract the utility file. # tar -zxvf /tmp/ocmwork/elxocm<version>.tgz 3. Execute the following command. # chmod 755 uninstall.sh #./uninstall.sh 4. Reboot the system and the procedure is complete. The OneCommand Manager application CLI (in Linux) 4-9

96 Confirming OCM_CLI version 1. Execute the following command. # hbacmd Version 2. See the value of "Command Line Interface" column The OneCommand Manager application CLI (in Linux)

97 Starting OCM_CLI The CLI Client component of the OneCommand Manager application provides access to the capabilities of the Remote Management library or the CIM interface from a console command prompt to get the management information. The CLI Client is intended for use in scripted operations from within shell scripts or batch files. The CLI Client is a console application named HbaCmd. A single operation is performed by entering "hbacmd", followed by a CLI client command and its possible parameters, at the command line. # hbacmd <command> [parameters] When the specified operation is completed, the command prompt is displayed. For a majority of commands, the first parameter following the command is the WWPN or MAC address of the port that the command is to act upon. The following syntax rules and usage are applicable for the HbaCmd application:. Parameters denoted within angle brackets < > are required.. Parameters denoted within square brackets [ ] are optional.. For Linux,program names must be in lowercase letters, therefore, the command line must begin with "hbacmd" (rather than "HbaCmd").. An optional IP address or host name can be specified using the "h" option with the following syntax: hbacmd [h=ip_address[:port] Hostname[:port]] <command> [parameters]. If the "h" option is omitted, the command is run on the local host.. If the "h" option is specified, the command is sent to the specified remote host (assuming it is specified correctly, the remote host is up, and the remote host is running the OneCommand Manager remote management agent.. The ":port" option is optional. If omitted, the OneCommand Manager remote management protocol uses the default TCP port. If specified, it uses the user-specified TCP port.. Examples: Using the IP address: hbacmd h= ListHBAs Using the host name: hbacmd h=cp-hp5670 ListHBAs. The "h" option is available for all commands except for the AddHost, RemoveHost, and the Version commands. The OneCommand Manager application CLI (in Linux) 4-11

98 . For FC ports, the WWPN of the adapter must be specified. Where the WWPN is specified, each pair of numbers within the WWPN is separated by colons (:) or spaces ( ). When using space separators, the entire WWPN must be enclosed in quotes (" "). For example, the following command displays the port attributes for the adapter with the specified WWPN: hbacmd PortAttributes 10:00:00:00:c9:20:20:20. For iscsi and NIC ports, the MAC address must be specified. Where a MAC address is specified, each pair of numbers within the MAC address is separated by a dash (-). For example, the following command sets the target properties for the UCNA port with the specified MAC address with an extended timeout value of "1": hbacmd SetTargetProperties iscsitarget 1. For NIC ports, only the permanent MAC address is supported for the port address parameter on an HbaCmd command line. Normally, for a UCNA port, the port's permanent MAC address and current MAC address parameters are equal. However, it is possible to set a userspecified (current) MAC Address that is different from the permanent MAC address. Also, for some implementations, it is possible to have multiple UCNA ports with the same current MAC addresses, but with unique permanent MAC addresses. Therefore, to ensure that the OneCommand Manager can access the correct port, only the permanent MAC address is supported. Note that both the permanent MAC address and the current MAC address are displayed by using the ListHBAs command The OneCommand Manager application CLI (in Linux)

99 Stopping OCM_CLI No operation is needed to stop OCM_CLI normally. The OneCommand Manager application CLI (in Linux) 4-13

100 OCM_CLI functions OCM_CLI functions Main OCM_CLI functions are as follows. Table 4-4: Main Functions Explanation Remarks Viewing the configuration information Viewing the configuration information of host, adapters, ASIC, port, device, etc. Setting the adapter Setting the driver parameter, and iscsi target. OCM_CLI commands (1) OCM_CLI Command List Table 4-5: Help Command Command Command Syntax Description Remarks help hbacmd Help Displays command information for [GroupName][CmdName] the HbaCmd application. Table 4-6: Adapter License Management Command Command Command Syntax Description Remarks ShowLicenseAdapterID hbacmd ShowLicenseAdapterID --- Not supported <WWPN MAC> InstallAdapterLicense hbacmd InstallAdapterLicense --- Not supported <WWPN MAC> <LicenseFile> ShowAdapterLicenseFe atures hbacmd ShowAdapterLicenseFeatures <WWPN MAC> --- Not supported Table 4-7: Attributes Command Command Command Syntax Description Remarks HbaAttributes hbacmd [h=<ipaddress>] hbaattributes <WWPN> Shows a list of all adapter attributes for all ports on the adapter. PortAttributes hbacmd <h=ipaddress of host> PortAttributes <WWPN MAC> Shows a list of all port attributes for the adapter. PortStatistics hbacmd PortStatistics <WWPN> --- Not supported ServerAttributes hbacmd ServerAttributes <WWPN MAC> --- Not supported SetPhyPortSpeed SetPhyPortSpeed <WWPN MAC --- Not supported address> <Mode> [Speed [Length]] SetPortEnabled SetPortEnabled <WWPN MAC address> <PortEnable> --- Not supported Table 4-8: Authentication Command Command Command Syntax Description Remarks AuthConfigList hbacmd AuthConfigList <WWPN> --- Not supported DeleteAuthConfig hbacmd DeleteAuthConfig <WWPN1> --- Not supported <WWPN2> <PasswordType> <Password> GetAuthConfig hbacmd GetAuthConfig <WWPN1> --- Not supported <WWPN2> GetAuthStatus, hbacmd GetAuthStatus <WWPN1> <WWPN2> --- Not supported 4-14 The OneCommand Manager application CLI (in Linux)

101 Command Command Syntax Description Remarks InitiateAuth hbacmd InitiateAuth <WWPN1> --- Not supported <WWPN2> SetAuthConfig hbacmd SetAuthConfig <WWPN1> --- Not supported <WWPN2> <PasswordType> <Password> <Parameter> <Value> SetPassword hbacmd SetPassword <WWPN1> <WWPN2> <Flag> <Cpt> <Cpw> <Npt> <Npw> --- Not supported Table 4-9: Boot Command Command Command Syntax Description Remarks EnableBootCode hbacmd EnableBootCode <WWPN MAC> --- Not supported <Flag> GetBootParams hbacmd GetBootParams <WWPN> <Type> --- Not supported SetBootParam hbacmd SetBootParam <WWPN> <Type> <Param> <Value1> [BootDev <Value2>] --- Not supported Table 4-10: DCB Command Command Command Syntax Description Remarks GetDCBParams hbacmd GetDCBParams <WWPN MAC> --- Not supported SetDCBParam hbacmd SetDCBParam <WWPN MAC> --- Not supported <Param> <Value> GetPGInfo hbacmd GetPGInfo <WWPN MAC> --- Not supported SetDCBPriority hbacmd SetDCBPriority <WWPN MAC> --- Not supported <PFC Priorities> <Priorities of PGID0> <Priorities of PGID1>...<Priorities of PGID7> SetCnaPGBW hbacmd SetCnaPGBW <WWPN MAC> <BW0 BW7> --- Not supported Table 4-11: Diagnostic Command Command Command Syntax Description Remarks EchoTest hbacmd EchoTest <WWPN Source> --- Not supported <WWPN Destination> <Count> <StopOnError> <Pattern> GetBeacon hbacmd GetBeacon <WWPN MAC> --- Not supported GetXcvrData hbacmd GetXcvrData <WWPN MAC> --- Not supported LoadList hbacmd LoadList <WWPN> --- Not supported LoopBackTest hbacmd LoopBackTest <WWPN MAC> --- Not supported <Type> <Count> <StopOnError> [Pattern] LoopMap hbacmd LoopMap <WWPN> --- Not supported PciData hbacmd PciData <WWPN MAC> <Type> --- Not supported PostTest hbacmd PostTest <WWPN> --- Not supported SetBeacon hbacmd SetBeacon <WWPN MAC> --- Not supported <BeaconState> SetCableNVP hbacmd SetCableNVP <WWPN MAC> --- Not supported <NVP> TDRTest hbacmd TDRTest <WWPN MAC address> --- Not supported SelfTest hbacmd SelfTest <WWPN MAC address> --- Not supported Wakeup hbacmd WakeUp <WWPN> --- Not supported Table 4-12: Driver Parameter Command Command Command Syntax Description Remarks DriverConfig hbacmd DriverConfig <WWPN> <FileName> --- Not supported <Flag> GetDriverParams hbacmd GetDriverParams <WWPN> Shows the name and values of each parameter. GetDriverParamsGlobal hbacmd GetDriverParamsGlobal <WWPN> Shows the name and the global value of each driver parameter. The OneCommand Manager application CLI (in Linux) 4-15

102 Command Command Syntax Description Remarks SaveConfig hbacmd SaveConfig <WWPN> <FileName> --- Not supported <Flag> SetDriverParam --- Changes a driver Not supported parameter and designates the scope of the change. SetDriverParamDefault s --- Changes all values to the default for the adapter(s). Not supported Table 4-13: Dump Command Command Command Syntax Description Remarks DeleteDumpFiles hbacmd DeleteDumpFiles <WWPN MAC> --- Not supported Dump hbacmd Dump <WWPN MAC> --- Not supported GetDumpDirectory hbacmd h=ipaddress[:port] m=cim --- Not supported [u=username] [p=password] [n=root/emulex] GetDumpDirectory <WWPN MAC> SetDumpDirectory ESX/ESXI using the CIM interace: --- Not supported hbacmd h=ipaddress[:port] m=cim [u=username] [p=password] [n=root/emulex] setdumpdirectory <DumpDirectoryName> ESX using the RM (remote management) interface: hbacmd h=ipaddress[:port] setdumpdirectory <DumpDirectoryName> GetRetentionCount hbacmd GetRetentionCount <WWPN MAC> --- Not supported SetRetentionCount hbacmd SetRetentionCount <WWPN MAC> --- Not supported <Value> GetDumpFileNames hbacmd GetDumpFileNames --- Not supported <WWPN MAC> GetDumpFile hbacmd [h=ipaddress] GetDumpFile <WWPN MAC> <filename> --- Not supported Table 4-14: FCoE Command Command Command Syntax Description Remarks GetFIPParams hbacmd GetFIPParams <WWPN> --- Not supported SetFIPParam hbacmd SetFIPParams <WWPN> --- Not supported GetFCFInfo hbacmd GetFCFInfo <WWPN> --- Not supported Table 4-15: iscsi Command Command Command Syntax Description Remarks AddARPTableEntry hbacmd [h=host_ip[:port] hostname[:port]] --- Not supported AddARPTableEntry <MAC_Address> <Dest_MAC_Address> <Dest_IP_Address> AddRouteTableEntry hbacmd [h=host_ip[:port] hostname[:port]] --- Not supported AddRouteTableEntry <MAC_Address> <Dest_IP_Address> <Subnet_Mask> <Gateway> AddTarget hbacmd [h=host_ip[:port] hostname[:port]] AddTarget <MAC_Address> <Target_IP> <Port> <iscsi_target_name> [ImmediateData=<0 1>] [HeaderDigest=<0 1>] [DataDigest=<0 1>] [Auth=<0 1 2> "TgtCHAPName" "TgtSecret" Adds a target to the list of targets seen by the initiator and logs into the target once it has been successfully created. "InitCHAPName" "InitSecret"] AddTargetPortal hbacmd [h=host_ip[:port] hostname[:port]] AddTargetPortal <MAC_Address> <Target_IP> <Port> [ImmediateData=<0 1>] [HeaderDigest=<0 1>] [DataDigest=<0 1>] [Auth=<0 1 2> "TgtCHAPName" "TgtSecret" "InitCHAPName" "InitSecret"] --- Not supported 4-16 The OneCommand Manager application CLI (in Linux)

103 Command Command Syntax Description Remarks CleariSNSServer hbacmd [h=host_ip[:port] hostname[:port]] --- Not supported CleariSNSServer <MAC_Address> DelARPTableEntry hbacmd [h=host_ip[:port] hostname[:port]] --- Not supported DelARPTableEntry <MAC_Address> <Dest_MAC_Address> <Dest_IP_Address> DelRouteTableEntry hbacmd [h=host_ip[:port] hostname[:port]] --- Not supported DelRouteTableEntry <MAC_Address> <Dest_IP_Address> <Subnet_Mask> <Gateway> DiscoveriSNSServer hbacmd [h=host_ip[:port] hostname[:port]] --- Not supported DiscoveriSNSServer <MAC_Address> GetInitiatorProperties hbacmd [h=host_ip[:port] hostname[:port]] GetInitiatorProperties <MAC_Address> Shows all the initiator login options for the GetiSCSILuns GetiSCSIPortStats GetNetworkConfiguratio n GetSessionInfo iscsiping ListSessions RemoveTarget RemoveTargetPortal SetInitiatorProperties SetNetworkConfiguratio n SetTargetLoginProperti es SetTargetProperties hbacmd [h=host_ip[:port] hostname[:port]] GetiSCSILuns <MAC_Address> <iscsi_target_name> hbacmd [h=host_ip[:port] hostname[:port]] GetiSCSIPortStats <MAC_Address> hbacmd GetNetworkConfiguration <MAC address> hbacmd [h=host_ip[:port] hostname[:port]] GetSessionInfo <MAC_Address> <iscsi_target_name> <TSIH <ISID_Qual Target_IP>> hbacmd [h=host_ip[:port] hostname[:port]] iscsiping <MAC_Address> <IP_Address> hbacmd [h=host_ip[:port] hostname[:port]] ListSessions <MAC_Address> <iscsi_target_name> hbacmd [h=host_ip[:port] hostname[:port]] RemoveTarget <MAC_Address> <iscsi_target_name> hbacmd [h=host_ip[:port] hostname[:port]] RemoveTargetPortal <MAC_Address> <Target_IP> <Port> hbacmd [h=host_ip[:port] hostname[:port]] SetInitiatorProperties <MAC_Address> [Initiator_Name="initiator_name"] [Initiator_Alias="initiator_alias"] [ImmediateData=<0 1>] [HeaderDigest=<0 1>] [DataDigest=<0 1>] [Auth=<0 1 2> "TgtCHAPName" "TgtSecret" "InitCHAPName" "InitSecret"] hbacmd [h=host_ip[:port] hostname[:port]] SetNetworkConfiguration <MAC_Address> <VLAN_ENABLED=<0 1> [<VLAN_ID=<0-4096>> <Priority=<0-7>>] <DHCP=<0 1>> [<IP_Address> <Subnet_Mask> [Gateway]] hbacmd [h=host_ip[:port] hostname[:port]] SetTargetLoginProperties <MAC_Address> <iscsi_target_name> [ImmediateData=<0 1>] [HeaderDigest=<0 1>] [DataDigest=<0 1>] [Auth=<0 1 2> "TgtCHAPName" "TgtSecret" "InitCHAPName" "InitSecret"] hbacmd [h=host_ip[:port] hostname[:port]] SetTargetProperties <MAC_Address> <iscsi_target_name> <ETO> specified port. Shows all the LUNs and their information for a specified target. Lists all session information for a specified session. Lists a port's TCP/IP information. Lists all session information for a specified session. Issues ICMP echo requests to a target. Lists all the sessions on a specified target. Not supported --- Not supported --- Not supported Sets the initiator properties for the specified port. Sets the TCP/IP configuration on a specified port. --- Not supported --- Not supported The OneCommand Manager application CLI (in Linux) 4-17

104 Command Command Syntax Description Remarks SetTPLoginProperties hbacmd [h=host_ip[:port] hostname[:port]] --- Not supported SetTPLoginProperties <MAC_Address> <Target_IP> <Port> [ImmediateData=<0 1>] [HeaderDigest=<0 1>] [DataDigest=<0 1>] [Auth=<0 1 2> TgtCHAPName TgtSecret InitCHAPName InitSecret] ShowARPTable hbacmd [h=host_ip[:port] hostname[:port]] ShowARPTable <MAC_Address> Shows the current ARP table for the specified port. ShowiSNSServer hbacmd [h=host_ip[:port] hostname[:port]] --- Not supported ShowiSNSServer <MAC_Address> ShowRouteTable hbacmd [h=host_ip[:port] hostname[:port]] ShowRouteTable <MAC_Address> --- Not supported ShowTarget ShowTargetPortal TargetLogin TargetLogout UpdateiSNSServer hbacmd [h=host_ip[:port] hostname[:port]] ShowTarget <MAC_Address> [<iscsi_target_name> refreshtargets] hbacmd [h=host_ip[:port] hostname[:port]] ShowTargetPortal <MAC_Address> [<Target_IP> <Port>] hbacmd [h=host_ip[:port] hostname[:port]] TargetLogin <MAC_Address> [<target_ip> <port>] hbacmd [h=host_ip[:port] hostname[:port]] TargetLogout <MAC_Address> <iscsi_target_name> <TSIH <ISID_Qual Target_IP> hbacmd [h=host_ip[:port] hostname[:port]] UpdateiSNSServer <MAC_Address> <Server_IP> <Port> Table 4-16: LUN Masking Command Shows the properties for a specified target. --- Not supported Logs in to a target. Logs out of a target. --- Not supported Command Command Syntax Explanation Remarks GetLunList hbacmd GetLunList <HBA WWPN> <Target --- Not supported WWPN> <Option> GetLunUnmaskByHba hbacmd GetLunUnMaskByHBA <HBA --- Not supported WWPN> <Option> GetLunUnmaskByTarg hbacmd GetLunUnMaskByTarget <HBA --- Not supported et WWPN> <Target WWPN> <Option> RescanLuns hbacmd RescanLuns <HBA WWPN> --- Not supported <Target WWPN> SetLunMask hbacmd SetLunMask <HBA WWPN> <Target WWPN> <Option> <Lun> <LunCount> <MaskOp> --- Not supported Table 4-17: Miscellaneous Command Command Command Syntax Explanation Remarks Download hbacmd Download <WWPN MAC> --- Not supported <FileName> ExportSANInfo hbacmd ExportSANInfo [format] --- Not supported GetQoSInfo hbacmd [h=host_ip[:port] hostname[:port]] GetQoSInfo <MAC_Address> Shows the QoS information for a specified NIC port. GetVPD hbacmd GetVPD <WWPN MAC> Shows the port s VPD. ListHBAs hbacmd [h=<ipaddress>] listhbas [local] [m=model] [pt=type] Shows a list of the manageable Emulex adapters found by local, remote in-band (FC), and remote outof-band (TCP/IP) discovery. --- Not supported GetElxSecInfo hbacmd [h=host_ip[:port] hostname[:port]] GetQoSInfo <MAC_Address> Reset hbacmd Reset <WWPN> --- Not supported TargetMapping hbacmd TargetMapping <WWPN> --- Not supported 4-18 The OneCommand Manager application CLI (in Linux)

105 Command Command Syntax Explanation Remarks SetCimCred hbacmd SetCimCred <username> --- Not supported <password> <namespace> <portnum> GetCimCred hbacmd GetCimCred --- Not supported AddHost hbacmd AddHost host_address --- Not supported RemoveHost hbacmd RemoveHost host_address --- Not supported CnaGetEventLog hbacmd CnaGetEventLog <WWPN MAC> --- Not supported CnaClearEventLog hbacmd CnaClearEventLog <WWPN MAC> --- Not supported SetPfcThrottle hbacmd SetPfcThrottle <WWPN> <0 1> --- Not supported Table 4-18: Persistent Binding Command Command Command Syntax Explanation Remarks AllNodeInfo hbacmd AllNodeInfo <WWPN> --- Not supported BindingCapabilities hbacmd BindingCapabilities <WWPN> --- Not supported BindingSupport hbacmd BindingSupport <WWPN> --- Not supported <Source> PersistentBinding hbacmd PersistentBinding <WWPN> --- Not supported <Source> RemoveAllPersistentBi nding hbacmd RemoveAllPersistentBinding <WWPN> --- Not supported RemovePersistentBindi ng SetBindingSupport SetPersistentBinding hbacmd RemovePersistentBinding <WWPN> <BindType> <ID> <SCSIBus> <SCSITarget> hbacmd SetBindingSupport <WWPN> <BindFlag> hbacmd SetPersistentBinding <WWPN> <Scope> <BindType> <TargetId> <SCSIBus> <SCSITarget> Table 4-19: Personality Management Command --- Not supported --- Not supported --- Not supported Command Command Syntax Explanation Remarks ShowPersonalities hbacmd ShowPersonalities <WWPN MAC> --- Not supported ChangePersonality hbacmd ChangePersonality <WWPN MAC> <personality_type> --- Not supported Table 4-20: VPort Command Command Command Syntax Explanation Remarks CreateVPort hbacmd CreateVPort <physical WWPN> --- Not supported auto [vname] DeleteVPort hbacmd DeleteVPort <physical WWPN> --- Not supported <virtual WWPN> ListVPorts hbacmd ListVPorts <physical WWPN> --- Not supported VPortTargets hbacmd VPortTargets <physical WWPN> --- Not supported <virtual WWPN> ListVMs hbacmd ListVMs <physical WWPN> <virtual WWPN> --- Not supported Table 4-21: WWN Management Command Command Command Syntax Explanation Remarks ChangeWWN hbacmd ChangeWWN <WWPN> <New --- Not supported WWPN> <New WWNN> <Type> GetWWNCap hbacmd GetWWNCap <WWPN> --- Not supported ReadWWN hbacmd ReadWWN <WWPN> <Type> --- Not supported RestoreWWN hbacmd RestoreWWN <WWPN> <Type> --- Not supported The OneCommand Manager application CLI (in Linux) 4-19

106 Configuration Information (1) HbaAttributes Command Devices : onboard CNA, CNA expansion card, FC expansion card Syntax : hbacmd hbaattrib <WWPN or MAC> WWPN : WWPN of the adapter. MAC : MAC address of the NIC or iscsi port. Examples : hbacmd hbaattrib c9-db HBA Attributes for c9-db Host Name : localhost.localdomain Manufacturer : Emulex Corporation Serial Number : FC Model : OCm11104-F2-HI Model Desc : Hitachi OCm11104-F2-HI 4-Port 10Gbps Converged Network Mezzanine Card HW Version : E3 A2 FW Version : Vendor Spec ID : 19A2 Number of Ports : 2 Driver Name : be2net.ko Device ID : 0710 Operational FW : PXE Boot : Disabled Driver Version : Board Temperature : Normal Function Type : NIC Sub Device ID : 3054 Port Number : 0 PCI Bus Number : 17 PCI Func Number : 0 Sub Vendor ID : 1054 Firmware Status : Working IPL Filename : M32FHIB5 NCSI Version : N/A Start-up Boot Code Version : FCoE Universal Version : 7.04a13 FCoE x86 BIOS Version : 4.02a15 FCoE EFI Version : 5.01a11 FCoE FCODE Version : 4.01a1 UEFI NIC Version : UEFI FCODE Version : UEFI iscsi Version : PCI Express Link Speed : 5GT/s PCI Express Bus Width : x The OneCommand Manager application CLI (in Linux)

107 (2) PortAttributes Command Devices : onboard CNA, CNA/LAN expansion card, FC expansion card Syntax : hbacmd PortAttrib <WWPN or MAC> WWPN : WWPN of the adapter. MAC : MAC address of the NIC or iscsi port. Examples : hbacmd PortAttrib 10:00:00:00:c9:dc:4a:49 Port Attributes for 10:00:00:00:c9:dc:4a:49 Node WWN : c9 dc 4a 49 Port WWN : c9 dc 4a 49 Port Symname : Emulex PPN-10:00:00:00:c9:dc:4a:49 Port FCID : F0900 Port Type : Fabric Port State : Operational Port Service Type : 8 Port Supported FC4 : Port Active FC4 : Port Supported Speed : GBit/sec Port Speed : 8 GBit/sec Max Frame Size : 2048 OS Device Name : /sys/class/scsi_host/host5 Num Discovered Ports : 2 Fabric Name : e a Function Type : FC The OneCommand Manager application CLI (in Linux) 4-21

108 (3) GetDriverParams Command Devices : onboard CNA(FCoE), CNA expansion card(fcoe), FC expansion card Syntax : hbacmd GetDriverParams <WWPN> WWPN : WWPN of the adapter. Examples : hbacmd GetDriverParams 10:00:00:00:c9:dc:4a:48 Driver Params for 10:00:00:00:c9:dc:4a:48. Values in HEX format. DX string Low High Def Cur Exp Dyn 00: log-verbose 0 ffffffff 0 0 a00d 1 01: lun-queue-depth e 1e a00d 4 02: scan-down a00d 4 03: nodev-tmo 1 ff 1e 1e a00d 1 04: topology a00d 5 05: link-speed a00d 5 06: fcp-class a00d 4 07: use-adisc a00d 1 08: ack a00d 4 09: cr-delay 0 3f 0 0 a00d 4 0a: cr-count 1 ff 1 1 a00d 4 0b: fdmi-on a00d 4 0c: max-luns 0 ffff ff ff a00d 4 0d: enable-npiv a00d 4 0e: use-msi a00d 4 (4)GetDriverParamsGlobal Command Devices : onboard CNA(FCoE), CNA expansion card(fcoe), FC expansion card Syntax : hbacmd GetDriverParamsGlobal <WWPN> WWPN : WWPN of the adapter. Examples : hbacmd GetDriverParam sglobal 10:00:00:00:c9:dc:4a:48 Driver Params for 10:00:00:00:c9:dc:4a:48. Values in HEX format. DX string Low High Def Cur Exp Dyn 00: log-verbose 0 ffffffff 0 0 a00d 1 01: lun-queue-depth e 1e a00d 4 02: scan-down a00d 4 03: nodev-tmo 1 ff 1e 1e a00d 1 04: topology a00d 5 05: link-speed a00d 5 06: fcp-class a00d 4 07: use-adisc a00d 1 08: ack a00d 4 09: cr-delay 0 3f 0 0 a00d 4 0a: cr-count 1 ff 1 1 a00d 4 0b: fdmi-on a00d 4 0c: max-luns 0 ffff ff ff a00d 4 0d: enable-npiv a00d 4 0e: use-msi a00d The OneCommand Manager application CLI (in Linux)

109 (5)GetInitiatorProperties Command Devices : onboard CNA(iSCSI), CNA expansion card(iscsi) Syntax : hbacmd GetInitiatorProperties <MAC> MAC : The MAC address of the UCNA port Examples : hbacmd GetInitiatorProperties c9-db Initiator login options for c9-db-56-49: Initiator iscsi Name: Initiator Alias: ImmediateData: HeaderDigest: DataDigest: AuthMethod: TargetCHAPName: InitCHAPName: iqn com.emulex:00-00-c9-db abcd Yes None None None Not Available Not Available Default Login Options: InitialR2T: Yes ImmediateData: Yes HeaderDigest: None DataDigest: None MaxConnections: 1 MaxOutstandingR2T: 1 FirstBurstLength: 8192 MaxBurstLength: MaxRecvDataSegmentLength: DefaultTime2Wait: 2 DefaultTime2Retain: 20 ErrorRecoveryLevel: 0 DataPDUInOrder: 1 DataSequenceInOrder: 1 (6)GetiSCSILuns Command Devices : onboard CNA(iSCSI), CNA expansion card(iscsi) Syntax : hbacmd GetiSCSILuns <MAC> <Target-name> MAC : The MAC address of the UCNA port Target-name: Target's iscsi name enclosed in quotes (string length: ) Examples : hbacmd GetiSCSILuns c9-db-56-4d iqn jp.co.hitachi:rsd.d8m.t a035 LUN 0: Vendor Name: HITACHI Model Number: DF600F Serial Number: LUN Type: 0 Capacity: GB Block Size: 512 The OneCommand Manager application CLI (in Linux) 4-23

110 (7)GetiSCSIPortStats Command Devices : onboard CNA(iSCSI), CNA expansion card(iscsi) Syntax : hbacmd GetiSCSIPortStats <MAC> MAC : The MAC address of the UCNA port Examples : hbacmd GetiSCSIPortStats c9-db-56-4d Port Statistics for c9-db-56-4d: Node Roles: Initiator Portal Count: 1 Node Count: 1 Session Count: 1 Session Failure Count: 0 Last Session Failure Type: OtherErrors Last Session Remote Node Name: Session Digest Errors: 0 Session Connection Timeout: 0 Session Format Errors: 0 Login Failures: 0 Last Failure Time: 0 Last Failure Type: UnknownFailure Last Target Failure Name: Last Target Failure Address: Login Accept Responses: 0 Login Other Failure Responses: 0 Login Redirect Responses: 0 Authentication Failure Responses: 0 Authentication Failures: 0 Login Negotiation Failures: 0 Logout Normals: 0 Logout Others: 0 Port Row Status: 1 Portal Role: Initiator Portal Protocol: 6 Portal Tag: 255 (8)GetNetworkConfiguration Command Devices : onboard CNA(iSCSI), CNA expansion card(iscsi) Syntax : hbacmd GetNetworkConfiguration <MAC> MAC : The MAC address of the UCNA port Examples : hbacmd GetNetworkConfiguration c9-db-56-4d TCP/IP Configuration for c9-db-56-4d: DHCP Enabled: No VLAN Enabled: NO VLAN ID: 0 Priority: 0 IP Address: Subnet Mask: Gateway: The OneCommand Manager application CLI (in Linux)

111 (9)ListSessions Command Devices : onboard CNA(iSCSI), CNA expansion card(iscsi) Syntax : hbacmd ListSessions <MAC> <Target-name> MAC : The MAC address of the UCNA port Target-name: Target's iscsi name enclosed in quotes (string length: ) Examples : hbacmd ListSessions c9-db-56-4d iqn jp.co.hitachi:rsd.d8m.t a035 Total Sessions: 1 Session 1 Initiator Name: iqn com.emulex:00-00-c9-db-56-4d Status: Open TSIH: ISID: 0x c0000 ISID Qualifier: 0 Target IP Address: Automatic Login: Yes iscsi Boot: No The OneCommand Manager application CLI (in Linux) 4-25

112 (10)GetSessionInfo Command Devices : onboard CNA(iSCSI), CNA expansion card(iscsi) Syntax : hbacmd GetSessionInfo <MAC><Target-name> <TSIH <ISID_Qual Target_IP>> MAC : The MAC address of the UCNA port Target-name: Target's iscsi name enclosed in quotes (string length: ) TSIH: TSIH value of the session (value: ) ISID_Qual Target_IP: ISID qualifier of the session (value: ) Examples : hbacmd GetSessionInfo c9-db-56-4d iqn jp.co.hitachi:rsd.d8m.t a Session Info for: TSIH: ISID Qualifier: 0 Session Negotiated Login Options ImmediateData: No MaxConnections: 1 MaxOutstandingsR2T: 1 FirstBurstLength: N/A MaxBurstLength: DefaultTime2Wait: 2 DefaultTime2Retain: 20 ErrorRecoveryLevel: 0 DataPDUInOrder: 0 DataSequenceInOrder: 0 Session Statistics Session Direction: 2 Cmd PDUs: 91 Response PDUs: 91 Xmit Data Octets: 0 Recv Data Octets: Digest Errors: 0 Connection Timeout Errors: 0 Session Target Alias: Connection Information iscsi Connection ID: 0 Status: Logged-In Source IP Address: Source Port: Destination IP Address: Destination Port: 3260 Redirected Destination IP Address: Redirected Destination Port: 0 Connection Negotiated Login Options Authentication Method: None HeaderDigest: None DataDigest: None MaxSendDataSegmentLength: TCPMSS: The OneCommand Manager application CLI (in Linux)

113 (11)ShowARPTable Command Devices : onboard CNA(iSCSI), CNA expansion card(iscsi) Syntax : hbacmd ShowARPTable <MAC> MAC : The MAC address of the UCNA port Examples : hbacmd ShowARPTable c9-db-56-4d MAC ADDRESS IP ADDRESS (12)ShowTarget Command Devices : onboard CNA(iSCSI), CNA expansion card(iscsi) Syntax : hbacmd ShowTarget <MAC> [<iscsi_target_name> refreshtargets] MAC : MAC address of the UCNA port iscsi_target_name: Target's iscsi name enclosed in quotes (string length: ) refreshtargets : Refresh all targets before displaying the information. Examples : hbacmd ShowTarget c9-db-56-4d iqn jp.co.hitachi:rsd.d8m.t a035 Target iscsi Name: iqn jp.co.hitachi:rsd.d8m.t a035 Target Alias: ETO: 90 Sessions: Yes Connected Sessions: Yes Login Options ImmediateData: HeaderDigest: DataDigest: AuthMethod: TargetCHAPName: InitCHAPName: Yes None None None Target Portal :3260 Target Portal Group Tag: 1 The OneCommand Manager application CLI (in Linux) 4-27

114 (13)ListHBAs Command Devices : onboard CNA, CNA/LAN expansion card, FC expansion card Syntax : hbacmd ListHBAs <pt=type> pt=type : Port type filter (valid types: NIC, iscsi, FC, FCoE) Examples : hbacmd ListHBAs pt=nic Manageable HBA List Permanent MAC : c9-db Current MAC : c9-db Flags : Host Name : localhost.localdomain Mfg : Emulex Corporation Serial No. : FC Port Number : 0 Mode : Initiator PCI Bus Number : 17 PCI Function : 0 Port Type : NIC Model : OCm11104-F2-HI Sub-Adapter ID : 01 Permanent MAC : c9-db-56-4c Current MAC : c9-db-56-4c Flags : Host Name : localhost.localdomain Mfg : Emulex Corporation Serial No. : FC Port Number : 1 Mode : Initiator PCI Bus Number : 17 PCI Function : 1 Port Type : NIC Model : OCm11104-F2-HI Sub-Adapter ID : 01 When the Emulex devices (CNA, LAN or FC) are busy, ListHBAs command may not display the device list or "Log Collect" tool may fail. In that case, try again after waiting about 5 minutes. Still the problem persists, reboot the OS. (14)GetQoSInfo Command Devices : onboard CNA, CNA/LAN expansion card Syntax : hbacmd GetQoSInfo <MAC> MAC : MAC address of the UCNA port. Examples : hbacmd GetQoSInfo c9-db NIC QoS values for c9-db-56-50: MaxBitsPerSecond: The OneCommand Manager application CLI (in Linux)

115 (15)GetVPD Command Devices : onboard CNA, CNA/LAN expansion card, FC expansion card Syntax : hbacmd GetVPD <WWPN MAC> MAC : MAC address of the UCNA port. Examples : hbacmd GetVPD c9-db VPD for HBA port c9-db Product Name : Hitachi OCm11104-F2-HI 4-Port 10Gbps Converged Network Mezzanine Card, NIC PF PN (Part Number) : OCm11104-F2-HI SN (Serial Number) : FC V0 : FC VB : PCIe 2.0 x8 5GT/s V1 : Hitachi OCm11104-F2-HI 4-Port 10Gbps Converged Network Mezzanine Card V2 : OCm11104-F2-HI V4 : 2 (16)ShowPersonalities Command Devices : onboard CNA, CNA/LAN expansion card Syntax : hbacmd ShowPersonalities <WWPN MAC> MAC : MAC address of the UCNA port. Examples : hbacmd CnaGetEventLog c9-db Adapter Personalities: NIC iscsi (active & configured) FCoE : 2 The OneCommand Manager application CLI (in Linux) 4-29

116 Configuring by OCM_CLI Configuring the Personality Configuring the personality of onboard CNA or CNA expansion card by the OCM_CLI is not supported. See "Hitachi Compute Blade Emulex Adapter User's Guide for Hardware" for configuring the personality. Configuring the PXE Boot Configuring the PXE by OCM_CLI is not supported. See "Hitachi Compute Blade Emulex Adapter User's Guide for Hardware" for configuring the PXE. Configuring UEFI on the system is necessary for the PXE Boot. See "EFI User's Guide" for the PXE boot Driver Parameter Settings The driver parameter can be set by the OCM_CLI. Setting the parameter "lun-queue-depth" is explained below. The performance may be improved by changing the setting of "lun-queue-depth". 1. Confirm the current value of "lun-queue-depth" parameter by "GetDriverParamsGlobal" command. Syntax : hbacmd GetDriverParamsGlobal <WWPN> WWPN : Adapter's WWPN Example : hbacmd GetDriverParamsGlobal 10:00:00:00:c9:dc:4a:48 2. Change the value of "lun-queue-depth" parameter by "SetDriverParam" command. For example, the "lun-queue-depth" value changes from "1e (default value)" to "1f" in this explanation. Execute the following command. Syntax : hbacmd setdriverparam <WWPN> <Flag1> <Flag2> <Param> <Value> Flag1 : L = Make change local for this adapter only. G = Make change global (all adapters on this host). Flag2 : P = Make change permanent (persists across reboot). T = Make change temporary. Param : Name of the parameter to modify. Value : New parameter value, decimal or hexadecimal (0xNNN) The OneCommand Manager application CLI (in Linux)

117 Example : hbacmd setdriverparam 10:00:00:00:c9:dc:4a:48 G P lunqueue-depth 1f 3. This procedure is successful if the following is displayed. Set Driver Parameter lun-queue-depth=0x1f (G P) for 10:00:00:00:c9:dc:4a:48 Driver Parameter 'lun-queue-depth' successfully set to '0x1f' for all emulex adapters on this host. 4. Reboot the system and the procedure is complete. The setting value of "lun-queue-depth" : The performance may be improved by changing the setting of "lun-queue-depth". The value is limited as follows. The number of LUN to be accessed * lun-queue-depth must be less than 512. (lun-queue-depth = 1 ~ 32) LUN is 17 for example: - When lun-queue-depth is 32 : 17 * 32 = 544 : NG - When lun-queue-depth is 31 : 17 * 31 = 527 : NG - When lun-queue-depth is 30 : 17 * 30 = 510 : OK iscsi Target Settings (1) Connecting to iscsi Target Connecting to or disconnecting the iscsi target can be set by the OCM_CLI. The procedure for CNA expansion card for example is explained below. This example is based on OCM_CLI version Confirm the MAC address of the adapter that is connected to the iscsi target. Syntax : hbacmd listhbas [local] [m=model] [pt=type] local : Only display local adapters m=model : Model filter (append * to end of model name for wildcard match, e.g. LP9*) pt=type : Port type filter (valid types: NIC, iscsi, FC, FCoE) The OneCommand Manager application CLI (in Linux) 4-31

118 Example : # hbacmd listhbas Manageable HBA List Permanent MAC : c9-da-be-3f Current MAC : c9-da-be-3f Logical HBA# : 0 Flags : Host Name : lin62x86 Mfg : Emulex Corporation Serial No. : FC Port Number : 0 Mode : Initiator PCI Bus Number : 42 PCI Function : 2 Port Type : iscsi Model : OCm11104-F2-HI Sub-Adapter ID : Set the IP address of the adapter. Syntax : hbacmd SetNetworkConfiguration <MAC_Address> <VLAN_ENABLED=<0 1> [<VLAN_ID=<0-4096>> <Priority=<0-7>>] <DHCP=<0 1>> [<IP_Address> <Subnet_Mask> [Gateway]] Example : MAC_Address : Only display local adapters VLAN_ENABLED : 0 = Disabled (Not supported) VLAN_ID : (Not supported) Priority : VLAN priority of the interface (Not supported) DHCP : 0 = Disabled (Not supported) IP_Address : New IP address (for example: ) Subnet_Mask : Subnet Mask (for example: ) Gateway : (Not supported) # hbacmd SetNetworkConfiguration c9-da-be-3f VLAN_Enabled=0 DHCP= "DHCP" function is not supported. - "VLAN" function is not supported. - "Gateway" function is not supported. 3. Confirm the IP address to have been set. Syntax : GetNetworkConfiguration <MAC_Address> MAC_Address : The MAC address of the UCNA port The OneCommand Manager application CLI (in Linux)

119 Example : # hbacmd GetNetworkConfiguration c9-da-be-3f TCP/IP Configuration for c9-da-be-3f: DHCP Enabled: No VLAN Enabled: NO VLAN ID: 0 Priority: 0 IP Address: Subnet Mask: Gateway: Set the iscsi initiator name. Syntax : hbacmd SetInitiatorProperties <MAC_Address> [Initiator_Name="initiator_name"] [Initiator_Alias="initiator_alias"] [ImmediateData=<0 1>] [HeaderDigest=<0 1>] [DataDigest=<0 1>] [Auth=<0 1 2> "TgtCHAPName" "TgtSecret" "InitCHAPName" "InitSecret"] Example : MAC_Address : MAC address of the CNA port Initiator_Name : Initiator iscsi name enclosed in quotes (string length: 1-224) Initiator_Alias : Initiator iscsi alias enclosed in quotes (string length: 0-32) ImmediateData : (Not supported. Use default: 1 = Yes) HeaderDigest : (Not supported. Use default: 0= None) DataDigest : (Not supported. Use default: 0= None) Auth : (Not supported. Use default: 0= None) TgtCHAPName : Target CHAP name enclosed in quotes (string length: 1-256) TgtSecret : Target Secret enclosed in quotes (string length: 12-16) InitCHAPName : Initiator CHAP name enclosed in quotes (string length: 1-256) InitSecret : Initiator Secret enclosed in quotes(string length:12-16) # hbacmd SetInitiatorProperties c9-da-be-3f initiator_name=iqn jp.co.hitachi:i.0 "ImmediateData", "HeaderDigest", "DataDigest", "Auth" functions are not supported. Use each default value. 5. Confirm the iscsi initiator name to have been set. Syntax : hbacmd GetInitiatorProperties <MAC_Address> The OneCommand Manager application CLI (in Linux) 4-33

120 MAC_Address : MAC address of the CNA port Example : # hbacmd GetInitiatorProperties c9-da-be-3f Initiator login options for c9-da-be-3f: Initiator iscsi Name: iqn jp.co.hitachi:i.0 Initiator Alias: ImmediateData: Yes HeaderDigest: None DataDigest: None AuthMethod: None TargetCHAPName: Not Available InitCHAPName: Not Available 6. Set the target Syntax : hbacmd AddTarget <MAC_Address> <Target_IP> <Port> <iscsi_target_name> [ImmediateData=<0 1>] [HeaderDigest=<0 1>] [DataDigest=<0 1>] [Boot=<0 1>] [Login=<0 1>] [Auth=<0 1 2> "TgtCHAPName" "TgtSecret" "InitCHAPName" "InitSecret"] Example : MAC_Address : The MAC address of the UCNA port. Target_IP : IP address of the target portal Port : Port number of the target portal (value: ) iscsi_target_name : Target's iscsi name enclosed in quotes (string length: ). ImmediateData : (Not supported. Use default: 1 = Yes) HeaderDigest : (Not supported. Use default: 0= None) DataDigest : (Not supported. Use default: 0= None) Boot : This optional parameter specifies whether the added target is a boot device: 0 = Added target is not a boot device. 1 = Added target is a boot device. Login : This optional parameter specifies whether to log in to the target after it has been added: 0 = Do not log in to the target. 1 = Specify log in to the target. If the Login parameter is omitted, the default is 1. Auth : (Not supported. Use default: 0= None) TgtCHAPNam : Target CHAP name enclosed in quotes (string length: 1-256). TgtSecret : Target Secret enclosed in quotes (string length: 12-16). InitCHAPName : Initiator CHAP name enclosed in quotes (string length: 1-256). InitSecret : Initiator Secret enclosed in quotes(string length:12-16). # hbacmd AddTarget c9-da-be-3f iqn jp.co.hitachi:t The OneCommand Manager application CLI (in Linux)

121 "ImmediateData", "HeaderDigest", "DataDigest", "Auth" functions are not supported. Use each default value. 7. Login to the target Syntax : hbacmd TargetLogin <MAC_Address> <iscsi_target_name> [target_portal_ip <port>] [ImmediateData=<0 1>] [HeaderDigest=<0 1>] [DataDigest=<0 1>] [Auth=<0 1 2> "TgtCHAPName" "TgtSecret" "InitCHAPName" "InitSecret"] Example : MAC_Address : The MAC address of the UCNA port. iscsi_target_name : The target s iscsi name enclosed in quotes (string length: ). Port : The port number of the target portal. The possible values are ImmediateData : (Not supported. Use default: 1 = Yes) HeaderDigest : (Not supported. Use default: 0= None) DataDigest : (Not supported. Use default: 0= None) Auth : (Not supported. Use default: 0= None) TgtCHAPNam : The Target CHAP name enclosed in quotes (string length: 1-255). TgtSecret : The Target Secret enclosed in quotes (string length: 12-16). InitCHAPName : The Initiator CHAP name enclosed in quotes (string length: 1-255). InitSecret : The Initiator Secret enclosed in quotes (string length: 12-16). # hbacmd TargetLogin c9-da-be-3f iqn jp.co.hitachi:t "ImmediateData", "HeaderDigest", "DataDigest", "Auth" functions are not supported. Use each default value. 8. Confirm the connection to the LU Syntax : hbacmd GetiSCSILuns <MAC_Address> <iscsi_target_name> MAC_Address : MAC address of the CNA port The OneCommand Manager application CLI (in Linux) 4-35

122 iscsi_target_name : Target s iscsi name enclosed in quotes (string length: ) Example : # hbacmd GetiSCSILuns c9-da-be-3f iqn jp.co.hitachi:t.0.0 LUN 0: Vendor Name: HITACHI Model Number: DF600F Serial Number: E LUN Type: 0 Capacity: GB Block Size: 512 (2) Disconnecting the iscsi target The procedure to disconnect the iscsi target is described below. 1. Confirm the MAC address of the port that is connected to the iscsi target. Syntax : hbacmd ListHBAs [pt=type] pt=type: Port type filter (valid types: NIC, iscsi, FC, FCoE) Example : # hbacmd listhbas Manageable HBA List Permanent MAC : c9-da-be-3f Current MAC : c9-da-be-3f Logical HBA# : 0 Flags : Host Name : lin62x86 Mfg : Emulex Corporation Serial No. : FC Port Number : 0 Mode : Initiator PCI Bus Number : 42 PCI Function : 2 Port Type : iscsi Model : OCm11104-F2-HI Sub-Adapter ID : Confirm the "TSIH" value in the session information of the target Syntax : hbacmd ListSessions <MAC> <Target-name> MAC : The MAC address of the UCNA port Target-name: Target's iscsi name enclosed in quotes (string length: ) 4-36 The OneCommand Manager application CLI (in Linux)

123 Example : # hbacmd ListSessions c9-da-be-3f iqn jp.co.hitachi:t.0.0 Total Sessions: 1 Session 1 Initiator Name: iqn jp.co.hitachi:t.0.0 Status: Open TSIH: ISID: 0x c0000 ISID Qualifier: 0 Target IP Address: Automatic Login: Yes iscsi Boot: No 3. Disconnect the target. Syntax : hbacmd TargetLogout <MAC_Address> <iscsi_target_name> <TSIH <ISID_Qual Target_IP>> Example : MAC_Address : The MAC address of the UCNA port. iscsi_target_name : The target s iscsi name enclosed in quotes (string length: ). TSIH : The TSIH value of the session. The possible values are ISID_Qual : The ISID qualifier of the session. The possible values are Target_IP : The target's IP address. # hbacmd TargetLogout c9-da-be-3f iqn jp.co.hitachi:t A target can be disconnected only per name. 4. Confirm that the LU has been disconnected. Syntax : hbacmd GetiSCSILuns <MAC_Address> <iscsi_target_name> Example : # hbacmd GetiSCSILuns c9-da-be-3f iqn jp.co.hitachi:t.0.0 This procedure is complete. The OneCommand Manager application CLI (in Linux) 4-37

124

125 5 Supported Operating Systems The Emulex adapters support the following operating systems. Supported Operating Systems Supported Operating Systems 5-1

126 Supported Operating Systems The Emulex adapters support the following operating systems. (1) The OneCommand Manager application GUI - Windows Server 2012 R2 Standard - Windows Server 2012 R2 Datacenter - Windows Server 2012 Standard - Windows Server 2012 Datacenter - Windows Server 2008 R2 Standard - Windows Server 2008 R2 Enterprise - Windows Server 2008 R2 Datacenter - Windows Server 2008 Standard - Windows Server 2008 Enterprise - Windows Server 2008 Datacenter - Windows Server 2008 Standard without Hyper-V - Windows Server 2008 Enterprise without Hyper-V - Windows Server 2008 Datacenter without Hyper-V - Windows Server 2008 Standard 32-bit - Windows Server 2008 Enterprise 32-bit - Windows Server 2008 Datacenter 32-bit - Windows Server 2008 Standard without Hyper-V 32-bit - Windows Server 2008 Enterprise without Hyper-V 32-bit - Windows Server 2008 Datacenter without Hyper-V 32-bit 5-2 Supported Operating Systems

127 (2) The OneCommand Manager application CLI - Red Hat Enterprise Linux7.2 (64-bit x86_64) - Red Hat Enterprise Linux7.1 (64-bit x86_64) - Red Hat Enterprise Linux 6.7 (64-bit x86_64) - Red Hat Enterprise Linux 6.6 (64-bit x86_64) - Red Hat Enterprise Linux 6.6 (32-bit x86) - Red Hat Enterprise Linux 6.5 (64-bit x86_64) - Red Hat Enterprise Linux 6.5 (32-bit x86) - Red Hat Enterprise Linux 6.4 (64-bit x86_64) - Red Hat Enterprise Linux 6.4 (32-bit x86) - Red Hat Enterprise Linux 6.2 (64-bit x86_64) - Red Hat Enterprise Linux 6.2 (32-bit x86) - Red Hat Enterprise Linux 5.9 (AMD/Intel64) - Red Hat Enterprise Linux 5.9 (x86) - Red Hat Enterprise Linux 5.7 (AMD/Intel64) - Red Hat Enterprise Linux 5.7 (x86) Supported Operating Systems 5-3

128

129 6 Restrictions This chapter describes the restrictions on the OCM and OCM_CLI. Restrictions on OCM and OCM_CLI Restrictions 6-1

130 Restrictions on OCM and OCM_CLI The OCM and OCM_CLI functions for the system have the following restrictions. For the system : Configuring the PXE is not supported. For network : "DHCP", "VLAN", "Gateway" functions are not supported. For iscsi : "ImmediateData", "HeaderDigest", "DataDigest", "Authentication" functions are not supported. For CNA : Configuring the personality is not supported. Else : - Dump function to create a "dump" file for a selected adapter is not supported. - When the Emulex devices (CNA, LAN or FC) are busy, ListHBAs command may not display the device list or "Log Collect" tool may fail. In that case, try again after waiting about 5 minutes. Still the problem persists, reboot the OS. For the functions above, see the following document. - "Hitachi Compute Blade Emulex Adapters User's Guide for Hardware (MK-99COM104)" - "Hitachi Compute Blade LAN Advanced Function Manual for Emulex (MK-99COM082)" 6-2 Restrictions

131 Acronyms and Abbreviations OS's Windows Server 2012 R2 Windows Server 2012 Windows Server 2008 R2 Windows Server 2008 Windows Server 2008 (32bit) Microsoft(R) Windows Server(R) 2012 R2 Standard Microsoft(R) Windows Server(R) 2012 R2 Datacenter Microsoft(R) Windows Server(R) 2012 Standard Microsoft(R) Windows Server(R) 2012 Datacenter Microsoft(R) Windows Server(R) 2008 R2 Standard Microsoft(R) Windows Server(R) 2008 R2 Enterprise Microsoft(R) Windows Server(R) 2008 R2 Datacenter Microsoft(R) Windows Server(R) 2008 Standard without Hyper- V TM Microsoft(R) Windows Server(R) 2008 Enterprise without Hyper-V TM Microsoft(R) Windows Server(R) 2008 Standard Microsoft(R) Windows Server(R) 2008 Enterprise Microsoft(R) Windows Server(R) 2008 Standard without Hyper- V TM 32-bit Microsoft(R) Windows Server(R) 2008 Enterprise without Hyper-V TM 32-bit Microsoft(R) Windows Server(R) 2008 Standard 32-bit Microsoft(R) Windows Server(R) 2008 Enterprise 32-bit RHEL5.7 Red Hat(R) Enterprise Linux(R) Server 5.7 RHEL5.9 Red Hat(R) Enterprise Linux(R) Server 5.9 RHEL6.2 Red Hat(R) Enterprise Linux(R) Server 6.2 RHEL6.4 Red Hat(R) Enterprise Linux(R) Server 6.4 RHEL6.5 Red Hat(R) Enterprise Linux(R) Server 6.5 RHEL6.6 Red Hat(R) Enterprise Linux(R) Server 6.6 RHEL6.7 Red Hat(R) Enterprise Linux(R) Server 6.7 RHEL7.1 Red Hat(R) Enterprise Linux(R) Server 7.1 RHEL7.2 Red Hat(R) Enterprise Linux(R) Server 7.2 ESXi5.0 VMware ESXi5.0 ESXi5.1 VMware ESXi5.1 ESXi5.5 VMware ESXi5.5 Adapters onboard CNA CNA expansion card LAN expansion card CB500 series onboard CNA 10Gb 4-port converged network expansion card (GG-CN3MXG2X1-Y) 10Gb 4-port LAN expansion card (GG-CN3MXG2X2-Y) Glossary Glossary-1

Hitachi Compute Blade Emulex Adapter User's Guide for Driver

Hitachi Compute Blade Emulex Adapter User's Guide for Driver Hitachi Compute Blade Emulex Adapter User's Guide for Driver FASTFIND LINKS Getting Help Contents MK-99COM103-13 2013-2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced

More information

Use Restrictions for Hitachi Compute Blade 500 Series FASTFIND LINKS. Getting Help Contents MK-91CB

Use Restrictions for Hitachi Compute Blade 500 Series FASTFIND LINKS. Getting Help Contents MK-91CB Use Restrictions for Hitachi Compute Blade 500 Series FASTFIND LINKS Getting Help Contents MK-91CB500072-16 2010-2016 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or

More information

Hitachi Compute Blade 2500 Intel LAN Driver Instruction Manual for SUSE Linux Enterprise Server

Hitachi Compute Blade 2500 Intel LAN Driver Instruction Manual for SUSE Linux Enterprise Server Hitachi Compute Blade 2500 Intel LAN Driver Instruction Manual for SUSE Linux Enterprise Server FASTFIND LINKS Getting Help Contents MK-99CB2500054-02 2016 Hitachi, Ltd. All rights reserved. No part of

More information

Hitachi Compute Rack Series RAID Driver Instruction Manual For Red Hat Enterprise Linux

Hitachi Compute Rack Series RAID Driver Instruction Manual For Red Hat Enterprise Linux Hitachi Compute Rack Series RAID Driver Instruction Manual For Red Hat Enterprise Linux FASTFIND LINKS Document Organization Getting Help Contents MK-90CRC008-00 2011-2013 Hitachi, Ltd. All rights reserved.

More information

Hitachi Compute Blade 500 Series

Hitachi Compute Blade 500 Series Hitachi Compute Blade 500 Series Server Blade Setup Guide Document Organization Product Version Getting Help Contents MK-91CB500012-09 2010-2015 Hitachi, Ltd. All rights reserved. No part of this publication

More information

Hitachi Compute Blade 500/2500 LSI MegaRAID SAS 3004 (imr) firmware update User s Guide

Hitachi Compute Blade 500/2500 LSI MegaRAID SAS 3004 (imr) firmware update User s Guide Hitachi Compute Blade 500/2500 LSI MegaRAID SAS 3004 (imr) firmware update User s Guide FASTFIND LINKS Document organization Product version Getting help Contents MK-99COM153-01 2010-2017 Hitachi, Ltd.

More information

Hitachi Compute Blade CB Base-T 4-port LAN Adapter User's Guide

Hitachi Compute Blade CB Base-T 4-port LAN Adapter User's Guide Hitachi Compute Blade CB2500 1000Base-T 4-port LAN Adapter User's Guide FASTFIND LINKS Getting Help Contents MK-99CB2500025-00 2014 Hitachi, Ltd. All rights reserved. No part of this publication may be

More information

BBI Quick Guide Networking OS for 1/10Gb LAN Switch Module

BBI Quick Guide Networking OS for 1/10Gb LAN Switch Module BBI Quick Guide Networking OS for 1/10Gb LAN Switch Module FASTFIND LINKS Product Version Getting Help Contents MK-99CB2500038-00 2014 Hitachi, Ltd. All rights reserved. No part of this publication may

More information

Hitachi Compute Blade HVM Navigator User s Guide - LPAR Configuration

Hitachi Compute Blade HVM Navigator User s Guide - LPAR Configuration Hitachi Compute Blade HVM Navigator User s Guide - LPAR Configuration FASTFIND LINKS Document organization Product version Getting help Contents MK-99COM042-11 2012-2015 Hitachi, Ltd. All rights reserved.

More information

Hitachi Compute Blade HVM Navigator User s Guide - LPAR Configuration

Hitachi Compute Blade HVM Navigator User s Guide - LPAR Configuration Hitachi Compute Blade HVM Navigator User s Guide - LPAR Configuration FASTFIND LINKS Document organization Product version Getting help Contents MK-99COM042-09 2012-2015 Hitachi, Ltd. All rights reserved.

More information

Use Restrictions for Hitachi Compute Blade 2500 Series FASTFIND LINKS. Getting Help Contents MK-99CB

Use Restrictions for Hitachi Compute Blade 2500 Series FASTFIND LINKS. Getting Help Contents MK-99CB Use Restrictions for Hitachi Compute Blade 2500 Series FASTFIND LINKS Getting Help Contents MK-99CB2500053-02 2014-2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced

More information

Hitachi Compute Blade 2000 LSI MegaRAID SAS 2208 RAID controller firmware update User s Guide

Hitachi Compute Blade 2000 LSI MegaRAID SAS 2208 RAID controller firmware update User s Guide Hitachi Compute Blade 2000 LSI MegaRAID SAS 2208 RAID controller firmware update User s Guide FASTFIND LINKS Document organization Product version Getting help Contents MK-99BDS2K105-02 2010-2014 Hitachi,

More information

Hitachi Compute Blade Logical VGA SnapShot

Hitachi Compute Blade Logical VGA SnapShot Hitachi Compute Blade Logical VGA SnapShot FASTFIND LINKS Getting Help Contents MK-99COM074-07 2010-2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted

More information

Hitachi Compute Blade Installation Guide for Oracle Solaris OS Installation Guide

Hitachi Compute Blade Installation Guide for Oracle Solaris OS Installation Guide Hitachi Compute Blade OS Installation Guide FASTFIND LINKS Getting Help Contents -99COM072-0 2010-2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in

More information

Hitachi Compute Blade HVM Navigator Installation Manual

Hitachi Compute Blade HVM Navigator Installation Manual Hitachi Compute Blade HVM Navigator Installation Manual FASTFIND LINKS Document organization Product version Getting help Contents MK-99COM023-17 2012-2016 Hitachi, Ltd. All rights reserved. No part of

More information

Use Restrictions for Hitachi Compute Blade 500 Series. Getting Help Contents MK-91CB

Use Restrictions for Hitachi Compute Blade 500 Series. Getting Help Contents MK-91CB Use Restrictions for Hitachi Compute Blade 500 Series FASTFIND LINKS Getting Help Contents MK-91CB500072-09 2010-2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or

More information

Hitachi Compute Blade Series Logical Partitioning Manager Version Upgrade / Revision Update Guide

Hitachi Compute Blade Series Logical Partitioning Manager Version Upgrade / Revision Update Guide Hitachi Compute Blade Series Logical Partitioning Manager Version Upgrade / Revision Update Guide FASTFIND LINKS Getting Help Contents MK-99BDS2K004-03 2012-2013 Hitachi, Ltd. All rights reserved. No part

More information

Use Restrictions for Hitachi Compute Blade 500 Series FASTFIND LINKS. Getting Help Contents MK-91CB

Use Restrictions for Hitachi Compute Blade 500 Series FASTFIND LINKS. Getting Help Contents MK-91CB Use Restrictions for Hitachi Compute Blade 500 Series FASTFIND LINKS Getting Help Contents MK-91CB500072-07 2010-2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or

More information

Hitachi Compute Blade 2500 Series

Hitachi Compute Blade 2500 Series Hitachi Compute Blade 2500 Series Logical partitioning manager User Guide Document Organization Product Version Getting Help Contents MK-99CB2500006-01 2014-2015 Hitachi, Ltd. All rights reserved. No part

More information

Hitachi Compute Blade Emulex Adapter User's Guide for Hardware

Hitachi Compute Blade Emulex Adapter User's Guide for Hardware Hitachi Compute Blade Emulex Adapter User's Guide for Hardware FASTFIND LINKS Getting Help Contents MK-99COM104-12 2013-2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced

More information

Hitachi Compute Blade Installation Guide for Oracle Linux OS Installation Guide

Hitachi Compute Blade Installation Guide for Oracle Linux OS Installation Guide Hitachi Compute Blade OS Installation Guide FASTFIND LINKS Getting Help Contents MK-99COM083-05 2010-2016 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted

More information

Hitachi Server Adapter for the SAP HANA Cockpit

Hitachi Server Adapter for the SAP HANA Cockpit Hitachi Server Adapter for the SAP HANA Cockpit v01.1.0 Release Notes Contents About This Document... 2 Intended Audience... 2 Getting Help... 2 About Release v01.1.0... 2 Supported Hardware and Software...

More information

Hitachi Command Suite. Automation Director. Messages MK-92HC221-02

Hitachi Command Suite. Automation Director. Messages MK-92HC221-02 Hitachi Command Suite Automation Director Messages MK92HC22102 2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic

More information

Hitachi Compute Blade Series Hitachi Compute Rack Series

Hitachi Compute Blade Series Hitachi Compute Rack Series Hitachi Compute Blade Series Hitachi Compute Rack Series OS Installation Guide for Windows Server Document Organization Product Version Getting Help Contents MK-99COM076-10 2013-2016 Hitachi, Ltd. All

More information

Hitachi Data Ingestor

Hitachi Data Ingestor Hitachi Data Ingestor Cluster Getting Started Guide Product Version Getting Help Contents MK-90HDI001-13 2010-2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted

More information

Hitachi NAS Platform F1000 Series

Hitachi NAS Platform F1000 Series Hitachi NAS Platform F1000 Series Backup Restore Features Supplement for Hitachi Data Protection Suite Product Version Getting Help Contents MK-92NAS069-07 2012-2015 Hitachi, Ltd. All rights reserved.

More information

Hitachi Storage Command Portal Installation and Configuration Guide

Hitachi Storage Command Portal Installation and Configuration Guide Hitachi Storage Command Portal Installation and Configuration Guide FASTFIND LINKS Document Organization Product Version Getting Help Table of Contents # MK-98HSCP002-04 Copyright 2010 Hitachi Data Systems

More information

Hitachi Data Ingestor

Hitachi Data Ingestor Hitachi Data Ingestor Backup Restore Features Supplement for IBM Tivoli Storage Manager Product Version Getting Help Contents MK-90HDICOM010-02 2010-2014 Hitachi, Ltd. All rights reserved. No part of this

More information

Hitachi Data Ingestor

Hitachi Data Ingestor Hitachi Data Ingestor Cluster Getting Started Guide Product Version Getting Help Contents MK-90HDICOM001-02 2010-2016 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or

More information

Hitachi Data Ingestor

Hitachi Data Ingestor Hitachi Data Ingestor Backup Restore Features Supplement for Hitachi Data Protection Suite Product Version Getting Help Contents MK-90HDICOM009-03 2010-2016 Hitachi, Ltd. All rights reserved. No part of

More information

Hitachi Dynamic Link Manager (for AIX) Release Notes

Hitachi Dynamic Link Manager (for AIX) Release Notes Hitachi Dynamic Link Manager (for AIX) 8.1.4-00 Release Notes Contents About this document... 1 Intended audience... 1 Getting help... 2 About this release... 2 Product package contents... 2 New features

More information

Hitachi Compute Blade 500 Series

Hitachi Compute Blade 500 Series Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide Document Organization Product Version Getting Help Contents MK-91CB500068-16 2012-2015 Hitachi, Ltd. All rights reserved. No part

More information

Hitachi Storage Connector for VMware vrealize Orchestrator

Hitachi Storage Connector for VMware vrealize Orchestrator Hitachi Storage Connector for VMware vrealize Orchestrator Contents v01.4.0 Release Notes Contents... 1 About this Document... 2 Intended Audience... 2 Getting Help... 2 Hardware and Software Support...

More information

Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User s Guide alive monitoring functions

Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User s Guide alive monitoring functions Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User s Guide alive monitoring functions FASTFIND LINKS Getting Help Contents MK-99COM065-02 2012-2014 Hitachi,

More information

Hitachi Storage Adapter for Microsoft Windows PowerShell

Hitachi Storage Adapter for Microsoft Windows PowerShell Hitachi Storage Adapter for Microsoft Windows PowerShell v06.2.0 Release Notes Contents About This Document... 2 System Requirements... 2 Software and Hardware Support... 3 HCP Requirement*... 5 Changes

More information

Hitachi Compute Blade 500 Series

Hitachi Compute Blade 500 Series Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide Document Organization Product Version Getting Help Contents MK-91CB500068-15 2012-2015 Hitachi, Ltd. All rights reserved. No part

More information

OneCommand Manager Application for Windows Release Notes

OneCommand Manager Application for Windows Release Notes OneCommand Manager Application for Windows Release Notes Version: 10.6.144.19 System: Windows Server 2008 (x86 and x64) Windows Server 2008 R2, Windows Server 2012, and Windows Server 2012 R2 (x64 versions,

More information

Tuning Manager. Hitachi Command Suite. Getting Started Guide MK-96HC FASTFIND LINKS Document Organization. Product Version.

Tuning Manager. Hitachi Command Suite. Getting Started Guide MK-96HC FASTFIND LINKS Document Organization. Product Version. Hitachi Command Suite Tuning Manager Getting Started Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-96HC120-23 2014, 2015 Hitachi, Ltd. All rights reserved No part

More information

Hitachi NAS Platform F

Hitachi NAS Platform F Hitachi NAS Platform F Plug-in for VMware vsphere Administrator's Guide Product Version Getting Help Contents MK-92NAS072-04 2013-2015 Hitachi, Ltd. All rights reserved. No part of this publication may

More information

Hitachi Compute Blade 2500 Series

Hitachi Compute Blade 2500 Series Hitachi Compute Blade 2500 Series UEFI Setup Guide Document Organization Product Version Getting Help Contents MK-99CB2500005-01 2014-2015 Hitachi, Ltd. All rights reserved. No part of this publication

More information

OneCommand Manager Application for Windows Release Notes

OneCommand Manager Application for Windows Release Notes OneCommand Manager Application for Windows Release Notes Version: 11.1.38.62 System: Windows Server 2008 (x86 and x64) Windows Server 2008 R2, Windows Server 2012, and Windows Server 2012 R2 (x64 versions,

More information

Hitachi Dynamic Link Manager (for AIX) Release Notes

Hitachi Dynamic Link Manager (for AIX) Release Notes Hitachi Dynamic Link Manager (for AIX) 8.4.1-00 Release Notes Contents About this document... 1 Intended audience... 1 Getting help... 2 About this release... 2 Product package contents... 2 New features

More information

BBI Quick Guide Networking OS for 1/10Gb LAN Switch Module. Product Version Getting Help Contents

BBI Quick Guide Networking OS for 1/10Gb LAN Switch Module. Product Version Getting Help Contents Networking OS for 1/10Gb LAN Switch Module FASTFIND LINKS Product Version Getting Help Contents 2014 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any

More information

Hitachi Unified Storage VM Block Module

Hitachi Unified Storage VM Block Module Hitachi Unified Storage VM Block Module Hitachi Volume Shredder User Guide FASTFIND LINKS Contents Product Version Getting Help MK-92HM7021-05 2012-2015 Hitachi, Ltd. All rights reserved. No part of this

More information

Hitachi Infrastructure Adapter for Microsoft System Center Operations Manager

Hitachi Infrastructure Adapter for Microsoft System Center Operations Manager Hitachi Infrastructure Adapter for Microsoft System Center Operations Manager v01.10.0 FASTFIND LINKS Contents Getting Help MK-92SCOM009-10 2012, 2016 Hitachi, Ltd. All rights reserved. No part of this

More information

OneCommand Manager Application for Windows Release Notes

OneCommand Manager Application for Windows Release Notes OneCommand Manager Application for Windows Release Notes Version: 10.0.803.9 System: Windows Server 2008 (x86 and x64) Windows Server 2008 R2, and Windows Server 2012 (x64 versions, Enterprise and Server

More information

Hitachi Dynamic Link Manager (for AIX) v Release Notes

Hitachi Dynamic Link Manager (for AIX) v Release Notes Hitachi Dynamic Link Manager (for AIX) v8.2.1-00 Release Notes Contents About this document... 1 Intended audience... 1 Getting help... 2 About this release... 2 Product package contents... 2 New features

More information

Hitachi Compute Blade 2500 Series

Hitachi Compute Blade 2500 Series Hitachi Compute Blade 2500 Series Logical Partitioning Manager User Guide Document Organization Product Version Getting Help Contents MK-99CB2500006-00 2014 Hitachi, Ltd. All rights reserved. No part of

More information

Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Storage Navigator Messages

Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Storage Navigator Messages Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Storage Navigator Messages FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-96RD613-18 Copyright

More information

Hitachi Virtual Storage Platform G1000

Hitachi Virtual Storage Platform G1000 Hitachi Virtual Storage Platform G1000 Hitachi Volume Shredder User Guide FASTFIND LINKS Contents Product Version Getting Help MK-92RD8025-01 2014 Hitachi, Ltd. All rights reserved. No part of this publication

More information

Replication Manager. Hitachi Command Suite. Application Agent CLI Reference Guide MK-90HC Document Organization. Product Version.

Replication Manager. Hitachi Command Suite. Application Agent CLI Reference Guide MK-90HC Document Organization. Product Version. Hitachi Command Suite Replication Manager Application Agent CLI Reference Guide Document Organization Product Version Getting Help Contents MK-90HC181-15 2014, 2015 Hitachi, Ltd. All rights reserved. No

More information

Hitachi WAN Optimizer VMware vsphere Setup Guide

Hitachi WAN Optimizer VMware vsphere Setup Guide Hitachi WAN Optimizer VMware vsphere Setup Guide FASTFIND LINKS Contents Product Version Getting Help MK-95HWO002-00 July 2016 2007, 2016 Hitachi, Ltd. All rights reserved. No part of this publication

More information

Hitachi Data Instance Director

Hitachi Data Instance Director Hitachi Data Instance Director Quick Start Guide FASTFIND LINKS Software Version Getting Help Contents MK-93HDID002-01 2013-2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced

More information

Compute Systems Manager

Compute Systems Manager Hitachi Command Suite Compute Systems Manager User Guide MK-91HC194-14 2014, 2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means,

More information

Hitachi Command Suite

Hitachi Command Suite Hitachi Command Suite Installation and Configuration Guide MK-90HC173-22 2014, 2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any

More information

Hitachi Content Platform HCP Data Migrator 6.1 Release Notes HCP-DM Version June 27, 2014

Hitachi Content Platform HCP Data Migrator 6.1 Release Notes HCP-DM Version June 27, 2014 Hitachi Content Platform HCP-DM Version 6.1.0.9 June 27, 2014 RN-90ARC031-10 2014 Hitachi Data Systems Corporation. All rights reserved. No part of this publication may be reproduced or transmitted in

More information

Global Link Manager. Hitachi Command Suite. Installation and Configuration Guide MK-95HC Document Organization. Product Version.

Global Link Manager. Hitachi Command Suite. Installation and Configuration Guide MK-95HC Document Organization. Product Version. Hitachi Command Suite Global Link Manager Installation and Configuration Guide Document Organization Product Version Getting Help Contents MK-95HC107-18 2015 Hitachi, Ltd. All rights reserved. No part

More information

Hitachi Command Suite. Automation Director. Installation and Configuration Guide MK-92HC204-02

Hitachi Command Suite. Automation Director. Installation and Configuration Guide MK-92HC204-02 Hitachi Command Suite Automation Director Installation and Configuration Guide MK-92HC204-02 2015 Hitachi, Ltd. All rights reserved No part of this publication may be reproduced or transmitted in any form

More information

Hitachi Data Ingestor

Hitachi Data Ingestor Hitachi Data Ingestor Single Node Getting Started Guide Product Version Getting Help Contents MK-90HDI028-09 2010-2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or

More information

Hitachi Compute Blade 500 Series

Hitachi Compute Blade 500 Series Hitachi Compute Blade 500 Series Management Module Setup Guide Document Organization Product Version Getting Help Contents MK-91CB500014-15 2012-2015 Hitachi, Ltd. All rights reserved. No part of this

More information

Hitachi Device Manager Mainframe Agent Release Notes Contents

Hitachi Device Manager Mainframe Agent Release Notes Contents Hitachi Device Manager Mainframe Agent 8.5.0-00 Release Notes Contents About this document... 2 Intended audience... 2 Getting help... 2 About this release... 2 Product package contents... 2 New features

More information

Emulex OneCommand Manager for VMware vcenter for LightPulse Adapters. User Guide Release 12.0

Emulex OneCommand Manager for VMware vcenter for LightPulse Adapters. User Guide Release 12.0 Emulex OneCommand Manager for VMware vcenter for LightPulse Adapters Release 12.0 July 5. 2018 , the pulse logo, Connecting everything, Avago Technologies, Avago, and the A logo are among the trademarks

More information

Hitachi Data Instance Director Disaster Recovery Reference

Hitachi Data Instance Director Disaster Recovery Reference Hitachi Data Instance Director Disaster Recovery Reference FASTFIND LINKS Software Version Getting Help Contents MK-93HDID004-00 2015 Hitachi, Ltd. All rights reserved. No part of this publication may

More information

Mainframe Analytics Recorder v Release Notes

Mainframe Analytics Recorder v Release Notes Mainframe Analytics Recorder v8.2.1-00 Release Notes Contents About this document... 1 Intended audience... 1 Getting help... 2 About this release... 2 Product package contents... 2 New features and important

More information

Compute Systems Manager

Compute Systems Manager Hitachi Command Suite Compute Systems Manager Messages FASTFIND LINKS Document Organization Product Version Getting Help Contents MK91HC19713 2014, 2015 Hitachi, Ltd. All rights reserved. No part of this

More information

Hitachi Dynamic Link Manager (for VMware ) Release Notes

Hitachi Dynamic Link Manager (for VMware ) Release Notes Hitachi Dynamic Link Manager (for VMware ) 8.5.1-04 Release Notes Contents About this document... 1 Intended audience... 1 Getting help... 1 About this release... 2 Product package contents... 2 New features

More information

Configuring Server Boot

Configuring Server Boot This chapter includes the following sections: Boot Policy, page 1 UEFI Boot Mode, page 2 UEFI Secure Boot, page 3 CIMC Secure Boot, page 3 Creating a Boot Policy, page 5 SAN Boot, page 6 iscsi Boot, page

More information

Hitachi Data Ingestor

Hitachi Data Ingestor Hitachi Data Ingestor Single Node Getting Started Guide Product Version Getting Help Contents MK-90HDI028-07 2010-2014 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or

More information

Hitachi Compute Blade 500 Series OS Installation Guide for Windows Server 2008

Hitachi Compute Blade 500 Series OS Installation Guide for Windows Server 2008 Hitachi Compute Blade 500 Series OS Installation Guide for Windows Server 2008 FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-91CB500037-07 2012-2014 Hitachi, Ltd. All rights

More information

Configuring Cisco UCS Server Pools and Policies

Configuring Cisco UCS Server Pools and Policies This chapter contains the following sections: Global Equipment Policies, page 1 UUID Pools, page 3 Server Pools, page 5 Management IP Pool, page 7 Boot Policy, page 8 Local Disk Configuration Policy, page

More information

Hitachi Command Suite. Dynamic Link Manager. (for VMware ) User Guide. Document Organization. Product Version. Getting Help. Contents MK-92DLM130-12

Hitachi Command Suite. Dynamic Link Manager. (for VMware ) User Guide. Document Organization. Product Version. Getting Help. Contents MK-92DLM130-12 Hitachi Command Suite Dynamic Link Manager (for VMware ) User Guide Document Organization Product Version Getting Help Contents MK-92DLM130-12 2014, 2015 Hitachi, Ltd. All rights reserved. No part of this

More information

Hitachi Converged Adapter 2.0 for Microsoft SCOM 2012 Administration Manual HCA for SCOM Administration Manual

Hitachi Converged Adapter 2.0 for Microsoft SCOM 2012 Administration Manual HCA for SCOM Administration Manual Hitachi Converged Adapter 2.0 for Microsoft SCOM 2012 Administration Manual MK-92UCP082-01 2014-2016 Hitachi Data Systems Corporation. All rights reserved. No part of this publication may be reproduced

More information

Hitachi Data Center Analytics v7.0 Release Notes

Hitachi Data Center Analytics v7.0 Release Notes Hitachi Data Center Analytics v7.0 Release Notes Contents About this document... 2 Intended audience... 2 Getting help... 2 About this release... 2 New features and important enhancements... 3 Distribution

More information

Hitachi Command Suite. Tuning Manager. Server Administration Guide. FASTFIND LINKS Contents. Product Version. Getting Help MK-92HC021-39

Hitachi Command Suite. Tuning Manager. Server Administration Guide. FASTFIND LINKS Contents. Product Version. Getting Help MK-92HC021-39 Hitachi Command Suite Tuning Manager Server Administration Guide FASTFIND LINKS Contents Product Version Getting Help MK-92HC021-39 2014, 2015 Hitachi, Ltd. All rights reserved. No part of this publication

More information

Hitachi Compute Blade 500 Series

Hitachi Compute Blade 500 Series Hitachi Compute Blade 500 Series Web Console User's Guide Document Organization Product Version Getting Help Contents MK-91CB500015-11 2012-2015 Hitachi, Ltd. All rights reserved. No part of this publication

More information

Contents. About This Document Intended Audience Getting Help Hardware and Software Support Storage Models (All adapters)...

Contents. About This Document Intended Audience Getting Help Hardware and Software Support Storage Models (All adapters)... Hitachi Adapters for Oracle Database v01.2.0 Release Notes Contents About This Document... 3 Intended Audience... 3 Getting Help... 3 Hardware and Software Support... 4 Storage Models (All adapters)...

More information

Emulex OneCommand Manager for VMware vcenter. User Guide Release 12.2

Emulex OneCommand Manager for VMware vcenter. User Guide Release 12.2 Emulex OneCommand Manager for VMware vcenter User Guide Release 12.2 January 28, 2019 , the pulse logo, Connecting everything, Avago Technologies, Avago, the A logo, Brocade, ClearLink, Emulex, ExpressLane,

More information

Hitachi Command Suite

Hitachi Command Suite Hitachi Command Suite Installation and Configuration Guide MK-90HC173-20 2014, 2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any

More information

Hitachi Virtual Storage Platform

Hitachi Virtual Storage Platform Hitachi Virtual Storage Platform Encryption License Key User Guide Document Organization Product Version Getting Help Contents MK-90RD7015-11 2010-2016 Hitachi, Ltd. All rights reserved. No part of this

More information

Hitachi Compute Blade 500 Series

Hitachi Compute Blade 500 Series Hitachi Compute Blade 500 Series Web Console User's Guide Document Organization Product Version Getting Help Contents MK-91CB500015-24 2012-2017 Hitachi, Ltd. All rights reserved. No part of this publication

More information

Hitachi Adapters for Oracle Database

Hitachi Adapters for Oracle Database Hitachi Adapters for Oracle Database v01.1.0 Release Notes Contents About This Document... 2 Intended Audience... 2 Getting Help... 2 Hardware and Software Support... 3 Hitachi Storage Adapter for Oracle

More information

Hitachi Data Ingestor Hyper-V Installation Guide 6.0.0

Hitachi Data Ingestor Hyper-V Installation Guide 6.0.0 Hitachi Data Ingestor Hyper-V Installation Guide 6.0.0 This guide provides instructions for installing Hitachi Data Ingestor (HDI) on Hyper-V. Instances of HDI installed on Hyper-V are referred to as VMA.

More information

Hitachi Data Ingestor

Hitachi Data Ingestor Hitachi Data Ingestor Single Node Getting Started Guide Product Version Getting Help Contents MK-90HDI028-10 2010-2016 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or

More information

OneCommand Manager Application for Solaris Release Notes

OneCommand Manager Application for Solaris Release Notes OneCommand Manager Application for Solaris Release Notes Version: 11.0.243.13 System: Solaris 10, and 10 Update 13 Solaris 11, and 11 Update 3 Solaris 12 (64-bit, x86, and SPARC) Date: March 1, 2016 Purpose

More information

Tuning Manager Software

Tuning Manager Software Hitachi Command Suite Tuning Manager Software Getting Started Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-96HC120-08 Copyright 2010 Hitachi Ltd., Hitachi Data Systems

More information

Hitachi Global Link Manager Release Notes

Hitachi Global Link Manager Release Notes Hitachi Global Link Manager 8.1.3-00 Release Notes Contents Contents... 1 About this document... 1 Intended audience... 1 Getting help... 1 About this release... 2 Product package contents... 2 New features

More information

Hitachi Command Suite. Command Director. CLI Reference Guide MK-90HCMD004-04

Hitachi Command Suite. Command Director. CLI Reference Guide MK-90HCMD004-04 Hitachi Command Suite Command Director CLI Reference Guide MK-90HCMD004-04 2014 Hitachi. Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means,

More information

Hitachi Infrastructure Director v1.0.0 Release Notes

Hitachi Infrastructure Director v1.0.0 Release Notes Hitachi Infrastructure Director v1.0.0 Release Notes Contents About this document... 1 Intended audience... 1 Getting help... 2 About this release... 2 Features... 2 System requirements... 3 Known issues...

More information

Emulex Universal Multichannel

Emulex Universal Multichannel Emulex Universal Multichannel Reference Manual Versions 11.2 UMC-OCA-RM112 Emulex Universal Multichannel Reference Manual Corporate Headquarters San Jose, CA Website www.broadcom.com Broadcom, the pulse

More information

Hitachi Command Suite

Hitachi Command Suite Hitachi Command Suite Virtual Appliance Installation Guide MK-92HC236-01 2016 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means,

More information

Hitachi Command Suite

Hitachi Command Suite Hitachi Command Suite 8.6 Virtual Appliance Installation Guide This manual explains how to use the virtual appliance for Hitachi Command. MK-92HC236-02 May 2018 2016, 2018 Hitachi, Ltd. All rights reserved.

More information

Hitachi Storage Adapter for Microsoft System Center Virtual Machine Manager

Hitachi Storage Adapter for Microsoft System Center Virtual Machine Manager Hitachi Storage Adapter for Microsoft System Center Virtual Machine Manager v01.3.0 Release Notes Contents About This Document... 2 Intended Audience... 2 Getting Help... 2 Hardware Requirements... 3 Volume

More information

Hitachi Virtual Storage Platform G1000

Hitachi Virtual Storage Platform G1000 Hitachi Virtual Storage Platform G1000 Hitachi Compatible FlashCopy User Guide FASTFIND LINKS Contents Product Version Getting Help MK-92RD8010-02 2014 Hitachi, Ltd. All rights reserved. No part of this

More information

Hitachi Virtual Storage Platform G1000

Hitachi Virtual Storage Platform G1000 Hitachi Virtual Storage Platform G1000 Hitachi Compatible FlashCopy User Guide Hitachi Compatible Mirroring for IBM FlashCopy V2 Hitachi Compatible Mirroring for IBM FlashCopy SE Product Version Getting

More information

Hitachi Virtual Storage Platform G1000

Hitachi Virtual Storage Platform G1000 Hitachi Virtual Storage Platform G1000 Nondisruptive Migration User Guide MK-92RD8086-01 2015 Hitachi, Ltd All rights reserved No part of this publication may be reproduced or transmitted in any form or

More information

Emulex OneConnect NIC Teaming and Multiple VLAN Driver and Application Release Notes

Emulex OneConnect NIC Teaming and Multiple VLAN Driver and Application Release Notes Emulex OneConnect NIC Teaming and Multiple VLAN Driver and Application Release Notes Version (Kit): 2.8.5 Date: March 2015 Purpose and Contact Information These release notes describe the installation

More information

Emulex OneConnect NIC Teaming and Multiple VLAN Driver and Application Release Notes

Emulex OneConnect NIC Teaming and Multiple VLAN Driver and Application Release Notes Emulex OneConnect NIC Teaming and Multiple VLAN Driver and Application Release Notes Version (Kit): 2.8.5 Date: September 2014 Purpose and Contact Information These release notes describe the installation

More information

Hitachi Adapter for Oracle Enterprise Manager - Database Cloning

Hitachi Adapter for Oracle Enterprise Manager - Database Cloning Hitachi Adapter for Oracle Enterprise Manager - Database Cloning v02.0.0 Release Notes Contents About This Document... 2 Intended Audience... 2 Getting Help... 2 About This Release... 2 Hardware Requirements...

More information

Hitachi Storage Adapter for Oracle VM

Hitachi Storage Adapter for Oracle VM Hitachi Storage Adapter for Oracle VM v05.1.0 Release Notes Contents About This Document... 2 Intended Audience... 2 Getting Help... 2 About Release v05.1.0... 2 Hardware and Software... 3 Host Interface...

More information

Emulex OneCommand Manager Application for LightPulse Adapters. User Guide Release 12.0

Emulex OneCommand Manager Application for LightPulse Adapters. User Guide Release 12.0 Emulex OneCommand Manager Application for LightPulse Adapters Release 12.0 July 5. 2018 , the pulse logo, Connecting everything, Avago Technologies, Avago, and the A logo are among the trademarks of and/or

More information