Product Information ECN 1324S EQN 1336S Absolute Rotary Encoders with DRIVE-CLiQ Interface for Safety-Related Applications 112015
ECN 1324S, EQN 1336S Rotary encoders for absolute position values with safe singleturn information Installation diameter 65 mm Expanding ring coupling 07B Taper shaft 65B Required mating dimensions = Bearing of mating shaft M1 = Measuring point for operating temperature M2 = Measuring point for vibration, see D 741714 1 = Clamping screw for coupling ring, width AF 2, tightening torque 1.25 0.2 Nm 2 = Die-cast cover 3 = Screw plug, widths AF 3 and 4, tightening torque 5+0.5 Nm 4 = Plug connector, 12-pin + 4-pin 5 = Screw DIN 6912 M5x50 08.8 MKL width AF 4, tightening torque 5+0.5 Nm 6 = Back-off thread M6 7 = Back-off thread M10 8 = Compensation of mounting tolerances and thermal expansion, no dynamic motion permitted 9 = Chamfer is obligatory at start of thread for materially bonding anti-rotation lock 10 = Direction of shaft rotation for output signals as per the interface description
Specifications ECN 1324S Singleturn EQN 1336S Multiturn These data apply for ID 1042274-01 ID 1042276-01 Functional safety For applications up to As single-encoder system for monitoring and closed-loop functions SIL 2 according to EN 61508 (further basis for testing: EN 61800-5-2) Category 3 PL d according to EN ISO 13849-1:2008 Safe in the singleturn range 27 x 10-9 (probability of dangerous failure per hour) PFH 1) Safe position 2) Device: ± 1.76 (safety-relevant measuring step SM = 0.7 ) mechanical coupling:± 2 (fault exclusion for loosening of shaft and stator coupling, designed for accelerations 300 ms 2 ) Interface DRIVE-CLiQ Ordering designation DQ01 Siemens software (version 12. 2. 2014) SINAMICS, SIMOTION: V4.4 HF4; SINUMERIK with safety: V4.4 SP2 Position valuesrevolution 16 777 216 (24 bits) Revolutions - Processing time Time_max_actual 8 µs System accuracy ± 20 Electrical connection PCB connector Rotary encoder: 12-pin Temperature sensor: 3) 4-pin Cable length 30 m (see the Interfaces of HEIDENHAIN Encoders brochure; with nmg = 1 incl. adapter cable) Voltage supply DC 24 V (10 V to 28.8 V) 4096 (12 bits) (possible up to DC 36.0 V without impairment of functional safety) Power consumption 4) (maximum) At 10 V: 900 mw; at 28.8 V: 1000 mw At 10 V: 1000 mw; at 28.8 V: 1140 mw Current consumption (typical) At 24 V: 38 ma (without load) At 24 V: 43 ma (without load) Shaft* Taper shaft Ø 9.25 mm; taper 1:10 Speed 15 000 rpm (at 2 position requests per rev.) Starting torque at 20 C 0.01 Nm Moment of inertia of rotor 2.6 10-6 kgm 2 Angular acceleration of rotor 1 x 10 5 rads 2 Axial motion of measured shaft ± 0.5 mm Vibration 55 to 2000 Hz 5) Shock 6 ms 300 ms 2 (EN 60 068-2-6) 2000 ms 2 (EN 60 068-2-27) Operating temperature 30 C to 100 C Trigger threshold of error message for excessive temperature 125 C (measuring accuracy of the internal temperature sensor: ± 7 K) Relative humidity 93 % (40 C21 d as per EN 60 068-2-78); without condensation Protection EN 60 529 IP 40 (see Insulation under General mechanical information in the Encoders for Servo Drives catalog; contamination due to the intrusion of liquids must be avoided) Mass 0.25 kg * 1) 2) 3) 4) 5) 12 000 rpm (at 2 position requests per rev.) Please select when ordering For application elevation 1000 m above sea level Further tolerances may occur in subsequent electronics after position value comparison (contact manufacturer of subsequent electronics) See Temperature measurement in motors in the Encoders for Servo Drives catalog. See General electrical information in the Interfaces of HEIDENHAIN Encoders brochure 10 Hz to 55 Hz, constant over distance, 4.9 mm peak to peak
ECN 1324S, EQN 1336S Rotary encoders for absolute position values with safe singleturn information Installation diameter 65 mm Expanding ring coupling 07B Blind hollow shaft for axial clamping 67M Required mating dimensions = Bearing of mating shaft M1= Measuring point for operating temperature M2 = Measuring point vibration, see D741714 1 = Clamping screw for coupling ring, width AF 2, tightening torque 1.25 0.2 Nm 2 = Die-cast cover 3 = Screw plug, widths AF 3 and 4, tightening torque 5+0.5 Nm 4 = Plug connector, 12-pin + 4-pin 5 = Screw DIN 6912 M5x25 08.8 MKL width AF 4, tightening torque 5+0.5 Nm 6 = Compensation of mounting tolerances and thermal expansion, no dynamic motion permitted 7 = Chamfer is obligatory at start of thread for materially bonding anti-rotation lock 8 = Direction of shaft rotation for output signals as per the interface description
Specifications ECN 1324S Singleturn EQN 1336S Multiturn These data apply for ID 1042274-03 ID 1042276-02 Functional safety For applications up to As single-encoder system for monitoring and closed-loop functions SIL 2 according to EN 61508 (further basis for testing: EN 61800-5-2) Category 3 PL d according to EN ISO 13849-1:2008 Safe in the singleturn range 27 x 10-9 (probability of dangerous failure per hour) PFH 1) Safe position 2) Device: ± 1.76 (safety-relevant measuring step SM = 0.7 ) mechanical coupling:± 2 (fault exclusion for loosening of shaft and stator coupling, designed for accelerations 300 ms 2 ) Interface DRIVE-CLiQ Ordering designation DQ01 Siemens software (version 12. 2. 2014) SINAMICS, SIMOTION: V4.4 HF4; SINUMERIK with safety: V4.4 SP2 Position valuesrevolution 16 777 216 (24 bits) Revolutions - Processing time Time_max_actual 8 µs System accuracy ± 20 Electrical connection PCB connector Rotary encoder: 12-pin Temperature sensor: 3) 4-pin Cable length 30 m (see the Interfaces of HEIDENHAIN Encoders brochure; with nmg = 1 incl. adapter cable) Voltage supply DC 24 V (10 V to 28.8 V) 4096 (12 bits) (possible up to DC 36.0 V without impairment of functional safety) Power consumption 4) (maximum) At 10 V: 900 mw; at 28.8 V: 1000 mw At 10 V: 1000 mw; at 28.8 V: 1140 mw Current consumption (typical) At 24 V: 38 ma (without load) At 24 V: 43 ma (without load) Shaft* Blind hollow shaft for axial clamping Ø 12.7 mm Speed 12 000 rpm (at 2 position requests per revolution) Starting torque at 20 C 0.01 Nm Moment of inertia of rotor 3.2 10-6 kgm 2 Angular acceleration of rotor 5 10 4 rads 2 Axial motion of measured shaft ± 0.5 mm Vibration 55 to 2000 Hz 5) Shock 6 ms 300 ms 2 (EN 60 068-2-6) 2000 ms 2 (EN 60 068-2-27) Operating temperature 30 C to 100 C Trigger threshold of error message for excessive temperature 125 C (measuring accuracy of the internal temperature sensor: ± 7 K) Relative humidity 93 % (40 C21 d as per EN 60 068-2-78); without condensation Protection EN 60 529 IP 40 (see Insulation under General mechanical information in the Encoders for Servo Drives catalog; contamination due to the intrusion of liquids must be avoided) Mass 0.25 kg * 1) 2) 3) 4) 5) Please select when ordering For application elevation 1000 m above sea level Further tolerances may occur in the subsequent electronics after the position value comparison (contact the manufacturer of the subsequent electronics) See Temperature measurement in motors in the Encoders for Servo Drives catalog. See General electrical information in the Interfaces of HEIDENHAIN Encoders brochure 10 Hz to 55 Hz, constant over distance, 4.9 mm peak to peak
Mounting The shaft of the rotary encoder is slid onto the motor s drive shaft and fastened with a central screw. It is particularly important to ensure that the positive-locking element of the stator coupling securely engages the corresponding slot in the mating part. Use a screw with materially bonding anti-rotation locking (see Mounting accessories). The stator coupling is clamped by an axially tightened screw in a location bore. Conditions required on the motor side for a safe mechanical connection: Mating shaft Mating stator Material Steel Aluminum Tensile strength Rm 600 Nmm 2 220 Nmm 2 Interface pressure PG 500 Nmm 2 200 Nmm 2 Surface roughness RZ 10 µm 10 µm Coefficient of expansion αtherm (10 to 17) 10-6 K -1 25 10-6 K -1 The following maximum torque Mmax is to be used when designing the mechanical fault exclusion for the shaft connection: Mmax = J x α + 0.2 Nm where J: Rotor moment of inertia (see Specifications of the encoder) α: Rotor angular acceleration (see Specifications of the encoder) The customer s mechanical design must ensure that the maximum torque Mmax occurring in the application can be transmitted. Mounting accessories Screws Screws (central screw, mounting screws) are not included in delivery. They can be ordered separately. ECN 1324S, EQN 1336S Central screws for fastening the shaft 1) For taper shaft 65B DIN 6912-M5 50-08.8-MKL ID 202264-54 For hollow shaft 67M DIN 6912-M5 25-08.8-MKL ID 202264-55 1) Lot size 10 or 100 pieces With coating for materially bonding anti-rotation lock Please note the information on screws from HEIDENHAIN in the catalog titled Encoders for Servo Drives, chapter General mechanical information under Rotary encoders with functional safety. Mounting aid The mounting aid serves to plug and unplug the PCB connector. It prevents damage to the cable because the strain is applied only to the connector. The wires themselves must not be strained. ID 1075573-01 For further mounting information and mounting aids, refer to the Encoders for servo drives catalog.
Integrated temperature evaluation These rotary encoders feature an internal temperature sensor integrated in the encoder electronics as well as an evaluation circuit for an external temperature sensor. In both cases, the respective digitized temperature value is transmitted purely serially over the DRIVE-CLiQ interface. It must be noted that the temperature measurement and the transmission of the temperature value are not safe in the sense of functional safety. The temperature measured by the internal temperature sensor is higher by a devicespecific and application-specific amount than the temperature at the measuring point M1 in accordance with the dimension drawing. The rotary encoders output the error message Alarm 405 if the internal temperature reaches a specific threshold. This threshold depends on the encoder model and is shown in the specifications. Keeping a sufficient distance from the error-message threshold is recommended during operation. The encoder s intended use requires compliance with the operating temperature at the measuring point M1.
Electrical requirements Switch-on and switch-off conditions Off Switchon SW startup System preparation including - Link detection - Topology detection - Configuration - Acyclic operation 36 V 10 V Duration depends on system 100 ms Position values available for controlling cyclic operation (safe mode for functional safety) Switchoff Up (at encoder) Operation t
Electrical connection Cables Cables inside the motor housing EPG Ø 3.7 mm; [2 2 0.06 mm + 4 0.06 mm 2 ] Complete with PCB connector (12-pin and 4-pin) and M12 flange socket (male), 8-pin; with wires for temperature sensor ID 1138203-xx 1) Complete with PCB connector (12 and 4 pin) and M23-SpeedTEC right-angle socket (male) 9-pin; with wires for temperature sensor ID 1120945-xx 1) Note for safety-related applications: Provide bit error rate! PUR connecting cable Ø 6.8 mm; [2 2 0.17 mm²) + (2 0.24 mm²)]; AP = 0.24 mm 2 Complete with M12 connector (female) and M12 coupling (male), 8 pins each ID 822504-xx Complete with 8-pin M12 connector (female) and Siemens RJ45 connector (IP 67) ID 1094652-xx Complete with 8-pin M12 connector (female) and Siemens RJ45 connector (IP20) ID 1093042xx Complete with M23 SpeedTEC connector (female) and Siemens RJ45 connector (IP20) ID 1121546-xx Complete with M23 SpeedTEC connector (female) and M12 coupling (male), 8-pin ID 1121536-xx AP: Cross section of power supply lines SpeedTEC is a registered trademark of Intercontec Pfeiffer Industriesteckverbindungen GmbH.
Electrical connection Pin layout 8-pin flange socket, M12 9-pin M23 right-angle socket 12-pin PCB connector 4-pin PCB connector Voltage supply M12 M23 Absolute position values Other signals 1) 1 5 3 4 7 6 8 4 5 6 1 2 3a 4b 6b 1a 2b 5a 1a 1b UP 0V RXP RXN TXP TXN T+ 2) T- 2) White WhiteGreen Gray Pink Violet Yellow Brown Green 12 4 1) 2) Only with output cables inside the motor Connections for external temperature sensor; evaluation optimized for KTY 84-130 (see Temperature measurement in motors in the Encoders for Servo Drives catalog) Cable shield connected to housing; Up = Power supply Vacant pins or wires must not be used! Encoder cables with a cable length > 0.5 m require strain relief of the cable DRIVE-CLiQ, SINUMERIK, SINAMICS and SIMOTION are registered trademarks of Siemens Aktiengesellschaft This Product Information supersedes all previous editions, which thereby become invalid. The basis for ordering from HEIDENHAIN is always the Product Information valid when the contract is made. Related documents: Adhere to the information in the following documents to ensure the correct and intended operation of the encoder: Catalog: Position Encoders for Servo Drives: 208922-xx ECN 1324S, EQN 1336S Mounting Instructions: 1038275-xx Technical Information: Safety-Related Position Measuring Systems596632 1089629 03 A 02 112015 PDF