ASHRAE CHAPTER TECHNOLOGY AWARD Illinois Chapter, Region VI

Similar documents
CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM

Energy Engineering: Tools and Trends

New Wisconsin Energy Code: What it Means for Me?

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Beverly D. Grappone Hall Certified LEED Silver Home of NHTI s State-of-the Art Nursing Simulation Center

DEDICATED HEAT RECOVERY UNIT (DHRC)

CASE STUDIES. Brevard Community College: Florida Power & Light. Cape Canaveral Air Force Station: NORESCO

Energy Action Plan 2015

Energy Efficiency in Existing Buildings, New Buildings and Large-Scale Application

ASHRAE. Shaping Tomorrow s Built Environment Today

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

ASHRAE elearning Course Catalog

Achieving Operational Excellence

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

HOURLY ANALYSIS PROGRAM v5.00 and v5.01

CenterPoint Energy Retro-Commissioning Program Application

SMART VENTILATION MANAGEMENT: CHANGING THE WAY WE THINK ABOUT VENTILATION

Trailblazer AGZ-E air-cooled scroll chillers

Building Tune-Up Program Application

HVAC Energy Management System

Trane mytest Water-cooled Chiller Performance Validation What you spec is what you get *

CARRIER HOURLY ANALYSIS PROGRAM v5.0

Energy Solutions for Buildings

The challenge is that BAS are often very complex with 1000s of data points to review. EMS Optimization Software

MSYS 4480 AC Systems Winter 2015

Air-Cooled Series R Chiller

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Your data center s hidden source of revenue

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

HPE Energy Efficiency Certification Service

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Committed to Energy Efficiency

where we are, where we could be, how we can get there. 12/14/2011

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

Predictive Software for Facilities Management

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Energy Performance Contracting

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

OUR ACHIEVEMENTS 4/27/2015. Why Certify? AEE Georgia Building Certifications. Pamela Moua, EIT, LEED AP O+M Sustainability Manager, Associate Engineer

AIR-COOLED A (Surprisingly) Cost-Effective Alternative to Water-Cooled Chiller Plants

Rack cooling solutions for high density racks management, from 10 to 75 kw

The Future. Today. YZ MAGNETIC BEARING CENTRIFUGAL CHILLER

Efficiency of Data Center cooling

SCHENDT ENGINEERING PRIOR EXPERIENCE

Data Center Energy and Cost Saving Evaluation

CECIP 18 GWH3. 16KMTCO 2 e 4 ABOUT CECIP CALTECH ENERGY CONSERVATION INVESTMENT PROGRAM ANNUAL REPORT 2014 ABOUT CALTECH INVESTED TO DATE

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

ASHRAE s Energy Efficiency Technical Guidance

Reducing Data Center Cooling Costs through Airflow Containment

Why would you want to use outdoor air for data center cooling?

CARRIER edesign SUITE NEWS

18 th National Award for Excellence in Energy Management. July 27, 2017

Driving Proactive Facility Operations with Automated HVAC Diagnostics

7th Annual Statewide Energy Efficiency Forum Applying Building Technologies to Realize Savings June 16, 2016

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Data Centers. Powerful Solutions That Put You in Control. Energy Management Solutions. Where your energy dollars are used. 1

Green IT and Green DC

Precision Controls of Indianapolis

ASHRAE UPDATE. DRC Report to Chapters 2017 Winter Conference. By Doug Cochrane, P.Eng., LEED AP Region II

Water cooled chiller plant (all-variable)

Continuous Commissioning at Sandia National Laboratories

James Donahue Control Consultants, Inc.

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Next Generation Cooling

Session 6: Data Center Energy Management Strategies

INNOVATE DESIGN APPLY.

ecoenergy Innovation Initiative Research and Development Component Public Report

Planning a Green Datacenter

INNOVATE DESIGN APPLY.

Magnitude magnetic bearing centrifugal chillers

Optimiz Chilled January 25, 2013

ASHRAE. Shaping Tomorrows Built Environment Today. Erich Binder - Director At Large

Case Study: Energy Systems Integration Facility (ESIF)

Magnitude magnetic bearing centrifugal chillers

Data Center Trends and Challenges

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

Commercial HVAC and Other Measures for 7P. Outline

Remote Monitoring. for Building HVAC Systems. A unique combination of human expertise and technology helps ensure optimum operation.

RAPID CITY CALL CENTER 1400 TURBINE DRIVE RAPID CITY, SD FOR SALE / FOR LEASE OFFICE / CALL CENTER 133,102 SQ. FT.

Comprehensive Energy Management & Utility Master Plan

LCP Hybrid Efficient performance with heat pipe technology

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

IT Air Conditioning Units

DR and EE Standards for SCE Buildings

Ecolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001

Introducing the Heat Wheel to the Data Center

Connect with Comfort. Phone not included. Smart Wi-Fi Universal Thermostats

Engineered Energy Solutions An Overview. Controls, Automation and Energy Conservation

Second Stakeholder Meeting for Nonresidential HVAC Proposals Based on ASHRAE Revisions to Waterside Economizer

Development of GSAS Framework

NEW FEATURES IN CARRIER BUILDING SYSTEM OPTIMIZER 1.40

Retro-Commissioning Report

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

ComEd Retro-Commissioning and Monitoring-Based Commissioning

LEADERS IN MEP, COMMISSIONING & ICT FOR BOSTON AND THE NORTHEAST

About Schneider Electric

Sir Walter Scott may not have been thinking of building automation systems. How BACnet. Is Connecting At ASHRAE s Headquarters

Transcription:

CHICAGO GRAND RAPIDS PHILADELPHIA DELHI AHMEDABAD ASHRAE CHAPTER TECHNOLOGY AWARD Illinois Chapter, Region VI Chinatown Branch Chicago Public Library 2100 South Wentworth Avenue Chicago, IL 60616

CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM 1. Category (Check one and indicate New or Existing, if applicable) Commercial Buildings New or Existing Institutional Buildings: Educational Facilities New or Existing Other Institutional New or Existing Health Care Facilities New or Existing Industrial Facilities or Processes New or Existing Public Assembly New or Existing Residential (Single and Multi-Family) 2. Name of building or project: City/State: Chinatown Branch Chicago Public Library Chicago, IL 3. Project Description: New, 16,000 sq. ft., state-of-the-art public library Project Study/Design Period: 09/2013 to 10/2014 Begin date (mm/yyyy) End date (mm/yyyy) Percent Occupancy at time of submission: 100% 4. Entrant (ASHRAE member with significant role in project): a. Name: Anand Sachin Last First Middle Membership Number: Chapter: Region: b. Address (including country): 5184161 Illinois VI 303 W. Erie Street, Suite 510 Chicago IL 60654 U.S. City State Zip Country c. Telephone: (O) (312) 915-0557 d. Email: sanand@dbhms.com e. Member s Role in Project: Design Engineer f. Member s Signature: 5. Engineer of Record: dbhms By affixing my signature above, I certify that the information contained in this application is accurate to the best of my knowledge. In addition, I certify that I have discussed this entry with the owner and have received permission from the owner to submit this project to the ASHRAE Technology Awards Competition.

CHICAGO GRAND RAPIDS PHILADELPHIA DELHI AHMEDABAD Located on a prominent site in the Chinatown neighborhood of Chicago, the new 16,000 sq. ft. Chinatown Branch Library aims to create a new civic, educational and social hub for the surrounding community, providing a place of discovery and learning in the new digital age. The state-of-the-art library offers a unique blend of traditional library services and the cutting edge technology featured in 21st century libraries, as well as striking modern architecture and community specific design features. The library has a large central space for community gathering and a large, a glass-enclosed community room for events and programs and two meeting rooms for small group work. It features a large reading room, a YOUmedia digital media space for teens, an expanded community room, children's reading room, meeting space for community use, state of the art technology, Wi-Fi, and self-checkout stations. The planning process for the library included strong participation from the community, and included visioning sessions with the Chinatown community and key stakeholders to create design goals and a spatial program concept. dbhms integrated design approach leveraged waste heat from a small on-site generator that further reduced energy consumption through a radiant tempering system. These systems are all proven, stateof-the-art technologies, yet needed to be tuned to work in harmony with one another to create an incredible environment that maintains the high standards set by the architectural design and are required by the Public Building Commission of Chicago, which developed the project on behalf of its client, Chicago Public Library. The library is designed to achieve LEED Gold Certification. Energy Efficiency The building systems are designed to be energy efficient, reducing overall consumption by 44.1% over a baseline system (ASHRAE 90.1-2007). The building expects to achieve 17 LEED points for optimizing energy performance (EAc1 LEED Version 3). Table 1 provides the predicted building energy performance. Table 1: Predicted Energy Performance Relative to ASHRAE 90.1-2007 Baseline Energy Model Baseline Electricity Consumption 100,499 kwh 196,661 kwh Gas Consumption 2,669 therms 2,967 therms Total Consumption 610 MMBtu 968 MMBtu The design consists of the following systems: The library includes a radiant heating and cooling system throughout all public areas of the building. The radiant system consists of suspended polypropylene radiant mats that are coordinated to provide an aesthetic effect throughout the building. Each mat has the capability for both direct radiant and convective conditioning. Small circulation fans are available to augment convective effect if needed. The building is zoned to optimize thermal comfort and operating efficiency. Coupled with the radiant system, a dedicated

outside air unit that provides ventilation air into the building. The system has energy recovery capabilities through an energy recovery core integral to the unit. The library includes both chilled and hot water systems serving all radiant and air handling equipment. A magnetic bearing air-cooled chiller with an integral economizer and condensing boilers are provided to serve these systems. Additionally, to optimize operating efficiency an array of gas absorption heat pumps provides either chilled or hot water under partial loads. Indoor Air Quality The open environment of the library provides effective opportunity for demand control ventilation. CO2 sensors are located within the space monitoring air quality and modulate outdoor air as required. Innovation The library s open environment provides a highly effective climate for radiant space conditioning. This is ideal for allowing uniformity in thermal comfort throughout the entire space, without warm and cold spots synonymous with all-air systems. Operation & Maintenance The library is open year round with a large number of visitors from local schools as well as community residents. The occupancy of the building varies by day and even by hour, which makes demand control ventilation essential for maintaining air quality as well as reducing energy use. Cost Effectiveness Chinatown Branch Library is a prime example of effective planning and cost effective design. The systems of the building are fine-tuned for the application, allowing more capital for finishes and program space. Examples of cost-effective design strategies include polypropylene hydronic piping and radiant mats, reduced ductwork for ventilation only, and ECM pumps. Environmental Impact Table 2 summarizes the predicted environmental impact of the building relative to the ASHRAE 90.1-2007 Appendix G Baseline: Table 2: CO2 Reduction from ASHRAE 90.1-2007 Baseline Energy Model Baseline Reduction LBs CO2 Emitted* 189,473 337,562 148,090 Estimated Building Energy Intensity (kbtu/sf) 37.3 59.1 21.8 *1.54 lbs CO2/ kwh and 116.97 lbs CO2/MMBtu- EPA 2009 2

CHINATOWN BRANCH LIBRARY SYSTEMS DIAGRAM RADIANT HOT & CHILLED WATER EXHAUST AIR CHILLER GAS ABSORPTION HEAT PUMP BOILER OUTSIDE AIR OUTSIDE AIR ENERGY RECOVERY CORE OUTSIDE AIR EXHAUST AIR HIGH GRADE HOT & CHILLED WATER