Lens of the access control (Optional) Camera: pick up the image. PP NN TS : configurator. ISP: entrance panel software upgrade connector

Similar documents
D45 System. Digital colour entrance panel with addresses list

Vandal-resistant entrance panel. Installer manual RA00054AA_I_EN01PC-12W16

Vandal-resistant entrance panel

D45 System. 3.5 Colour handsfree internal unit. Front view

item Instruction sheet PART. T6101D - 05/05-01 PC

05/16-01 PC Monobloc Audio Digital Entrance Panel. Installer manual

TiMonoblocEntrancePanel

Sfera Display Module. Installer manual 05/16-01 PC

TiSferaDesign. Instructions for use.

2 WIRE video door entry system

Agenda. August 23, 2017 Slide 2

D45 System. 7 touch screen handsfree internal unit. Front & side views

2 WIRE Video Door Entry system

Front view. Internal view. Legend

PUSH BUTTON PANEL. SECTION 3A (Rev. B) SECTION CONTENTS. Download from Technical Manuals area. sec.3a

Nortel IP Phone 2001 User Guide (CICM)

Installation Manual & User Instructions. MultiCom 100 / 500

Sfera Keypad Module. Installer manual 07/12-01 PC

CATALOGUE D45 High performance door entry system

Installation Manual & User Instructions. MultiCom 500

EN TECHNICAL MANUAL. Icona door entry monitor Art. 6601W - Art. 6601W/BM. Passion.Technology.Design.

Installation and User Guide

GSM Voice Active Monitoring OTP-GSM89

EN TECHNICAL MANUAL. Mini door entry monitor with handset Art / Passion.Technology.Design.

EN TECHNICAL MANUAL. ViP Mini hands-free monitor art. 6721W. Passion.Technology.Design.

8-wire Digital. Audio/Video Intercom Systems. Catalogue

Installation Manual & User Instructions

D45. High performance door entry system CATALOGUE A Group Brand

MULTIFUNCTION DEVICE: Type 6949

D1265. Installation Guide. Touchscreen Keypad

Configuring a Net2 Entry Monitor

180 Series Keypad. Handbook. Revision 2.1

CLASSE 300 THE CONNECTED VIDEO INTERNAL UNIT

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

Nortel IP Phone 1120E/1140E User Guide (CICM).

Configuring a Net2 Touch Entry Panel

Nortel IP Phone 1120E User Guide

IPERVOICE SYSTEM SWITCHBOARD INSTALLATION AND USER MANUAL

WiFi Video Doorbell. User Manual

Configuring a Net2 Entry Panel

Video Display Eteris. Installation manual 01GF-28W10

CLASSE 300 THE CONNECTED VIDEO INTERNAL UNIT

Phone Quick Reference Guide. Rev2. M I T E L. EMEA CALA. Global Headquarters U.S. Asia Pacific

Mini ViP and WIRES THE MINI SERIES IS COMPLETED WITH THE NEW IP VERSIONS

EN TECHNICAL MANUAL. Handsfree door entry phone Mini 6750W, Mini 6751W. Passion.Technology.Design.

smartentry Wireless Video Doorphone User Manual

2015/09/24. M-Touch

epad 5.0 Mobile Keypad

DT243-D4 4.3" COLOR TFT MONITOR USER MANUAL. Please read this manual carefully before using the product you purchase,and keep it well for future use.

NEW. Bticino modular entrance panels. Sfera. CHOOSE YOUR FINISH Replace the dots in the Cat. No. with either 1, 2, or 3 to select the desired finish

VIVO KIT. KIT VIDEO VIVO Code 97738EI V03_14. Page 2

Quick Guide for SD-902 Door phone Intercom

INTERQUARTZ. Doorphone ID 201 Doorphone ID 202 Doorphone ID 204. User manual

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation

Call Origination: Speaker/Mic: Camera: Mounting: Construction: Directory: Camera Aperture: Dimensions: Architects and Engineers Specification

Ref. 1717/31 (White) Ref. 1717/33 (Black)

USER MANUAL. 7" Intelligent Digital Video Doorphone Indoor Unit TIP-DPH-INT7. Product Overview Product Description

K44 Code lock. Technical manual

Aastra 673xi / 675xi. Telephony with SIP Phones at the Aastra 800/OpenCom 100 Communications System User Guide

SRM9030plus Mobile Radio Transceiver MPT1327 Trunked. Operating Instructions Issue 1.1

User Manual MiniVision

Emergency Phone with 2-Way Speech SOS Pendant Model: 1225

Access control panel U-Prox IC E (Elevator control)

Aastra 6725ip Microsoft Lync 2010 Phone Work Smart User Guide

WiFi Wireless Video Door Phone. User Manual

791/793 Easy Entry Keypads

Metaphase DDC-3. Technologies USER MANUAL. Version 7.X August metaphase-tech.com. pg. 1

Configuring a Net2 Entry Panel

Digital 2.4GHz 3.5 LCD Monitor

Vacon HVAC100 Commissioning Guide

Configuring and Managing the IP Camera

Quick Start Guide. GV-CS1320 Camera Access Controller

Home Automation, Inc. Model 32A00-5. OmniTouch with Video Touchscreen

DESSMANN - FINGERPRINT LOCK

Wireless VoIP Phone Model: BT-WFP1000

Video Display Eteris User guide 01GF-28W10

2 -Wire Intercom System

Thomson Telecom S.A.S with a capital of RCS Copyright THOMSON 2005 All rights reserved 09/

AS Keypad User Manual

Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules

8. Electric Lock Connection

IP Phone 1210 User Guide CICM

Installation Instructions

Installation and User Guide

From lab to production, providing a window into the process. Universal Input Indicator Start-up Guide. Operating Manual.

SKANTI. Scansat-7701 Telephone System for Maritime Communication

2214 EVENT LOGGER MODULE FOR THE VX2200 SYSTEM

INSTALLATION SHEET 791 and 793 Easy Entry Keypads

Installation and Operation Manual Model 9A02 Software Version 2.0

ZDL-V200. Refer to Steps: 1 Thru. 4 Please Follow Wiring Steps Carefully.

Size of Mounting Plate /2 inches High x 7 inches Wide x 3 1/16 inches Deep (includes circuit boards)

H2i. s u p p o r f i n g e r t e c. c o m. H2i. Simple Fingerprint Door Access & Time Attendance System. User Guide

FB00084-EN PROGRAMMING MANUAL DDVC/08 VR - DDC/08 VR

New Account Creation. 2. Launch the CarLink app. from your phone s application list. 3. Enter a name for the vehicle.

MobileCam. GM-GV3 MobileCam & Viewer Software User Guide

GV-AS200 Controller. Hardware Installation Guide

System Administrator s Manual Arista Systems Corporation

Figure 1: The BM12 Button Module

4 Wire Video Intercom System

Do not place or mount Ocli 1 in an area where it will be exposed to water. Ocli 1 is designed for indoor use.

Transcription:

322011 LE06448AA01CN-13W17 Description 12 1 11 10 9 23 13 14 2 22 15 16 8 21 17 7 3 20 6 4 5 19 18 1. Compensation Lamp 10. Lens of the access control (Optional) 18. Targe BUS use CAT5 table connect to targe 2. Key used to send the call to the selected resident 3. Door lock release key 4. Photosensitive lamp 5 Microphone 11. 12. 13. 14. Loudspeaker Camera: pick up the image PP NN TS : configurator ISP: entrance panel software upgrade connector 19. 20. SYSTEM BUS use CAT5 cable connect to system 6P connector +12V/GND: supply power to A/C module UNLOCK: unlock signal output by A/C module DAS: connector of electronical lock status signal LOCK-/LOCK+: connect electronical lock. 6. Management center pushbutton: call the management center 15. SPK: adjust loudspeaker volume 21. SPK-OUT/GND/GND/SPK-OUT: connect entrance panel loudspeaker 7. Delete key 16. MIC: adjust microphone volume 22. V-GAIN: video gain setting 8. Number pushbutton 17. VIDEO-IN/GND/NC/+12V/LED-: connect entrance panel camera and compensation Lamp 23. RESET: for password reset 9. Resident search keys

Technical data - standby current 25 ma; voltage 30 Vdc working current 245mA; voltage 30 Vdc 125 mm 44,5 mm - setting entrance panel address by configuration resistors 325 mm P P N N T S P: Entrance panel address N: Call number (Not used) T: Door lock time delay(not used) S: Type of call signal(not used) Installation on the wall Installation on the door Note - Embedded box for installation on door should be bought separately. - This installation instruction is just for entry panel. For embedded box installation, please refer to embedded box installation instruction. 2

Function setting 1.Configuration using the keypad 1.1Access to the configuration menu Press and hold down keys for more than 10 seconds Confirm OK 1.3.3 Home page The home page can be used to enter a customised welcome message, or any other message; the message can use a maximum of three rows of text of 15 characters (Template); to switch from upper case to lower case and vice versa use the arrow keys. The length of time the - message is displayed on the screen (5, 10, or 15 sec.) (Timeout). Entering the text, Press OK Enter the access code (default 1234) If the correct code has been entered, direct access to the configuration menu will be granted Select the row text and confirm OK where to enter the new text, or change the existing To exit the configuration menu, or to return to the previous menu, select EXIT and press OK Press OK to select the text field 1.2 If the password is forgotten If the password has been forgotten it s possible to reset it in this way: Press the RESET key which on the back of the device for about 6s. password recover the default 1234. 1.3 Panel settings Enter the text using the alphanumeric keypad, in the same way as you would write an SMS message on your mobile phone Confirm OK The new message will appear continuously on the home page for the period set a Timeout 1.3.4Restore default settings Select the menu, Confirm OK Select the function, Press OK 1.3.1Device settings The DEVICE SETTINGS submenu can be used to set the following functions: Brightness Display brightness adjustment Contrast Contrast adjustment(not used) Exit return to the previous menu 1.3.2 Password setup Press OK The settings of the entrance panel revert to the factory settings. This function does not delete the data contained in the residents address book. 1.4 Address book This menu can be used to enter residents data, including call codes and door lock release codes, as well as for performing any other functions described in the following paragraphs. To change the access password: Press OK,Enter the new password 6789 1.4.1 Calling mode - List of names This setting determines how the names of the residents are displayed; if enabled, the display will show the following message: 3

To search the desired name use the indicated key, or enter the surname using the alphanumeric keypad. NO = The name and the surname of the resident are hidden, the call is possible by entering the ID number. Apart address: Enter the handset SCS address Call code: Numerical call code Lock code: Door lock release numerical code 1.4.7 Delete contact This function gives the possibility of deleting the contact selected 1.4.2 Calling mode - Type of code Enter the type of code to use when calling the residents Select the contact to change,press OK Apart address: SCS address of the handset Call code : Numerical code assigned to the resident The request to confirm the elimination of the contact appears, press OK 1.4.3Calling mode Recall 1.4.8Delete address book This function gives the possibility of deleting all the contacts of the entrance panel address book, press OK. When this function is enabled, the entrance panel will automatically repeat the call every 10 seconds for up to 4 times. 1.4.4 Contact setting The call codes and the door lock release codes can be set with a length of 1 to 8 digits for the Call code and 4 to 9 digits for the Lock code. 1.5Phonic module settings The configurations of this menu are only possible if the phonic (speaker) module is not configured physically Call code digits: Length of the codes for calling residents (default 4 digits) Lock code digits: Length of the door lock release codes (default 9 digits) 1.4.5 Modify contact This function gives the possibility of changing the contact selected P - panel number: Entrance panel SCS address T - Lock time: Door lock time delay (Not used) Switchboard: SCS address of the switchboard Signal type of lock: ON=open NC=close Dismantle alarm : ON=enable OFF=unable 1.6 FW versions This menu shows the versions of the firmware installed on the device. Select the contact to change, Confirm OK 1.4.6 New contact This function can be used to enter new residents in the address book 2 Using the entrance panel 2.1Calling residents Residents may be called in three different ways: 2.1.1Searching using the arrow keys Press one of the arrow keys to access the address book For each resident it will be possible to set the following data: ID number: Identification number; the entrance panel assigns a progressive num ber to each resident. This function gives the possibility of changing this ID with a 4 digits number defined by the installer. Surname (Text 1*): Surname of resident Name (Text 2*): Name of the resident Public: YES = The name and the surname of the resident appear on the display during the selection for call Use the arrow keys to scroll through the names until the name of the desired resident appears; for fast scrolling press and hold the key, Press to send the call OK. 4

2.1.2Tramite ricerca per cognomen Press one of the arrow keys to access the address book Use the keypad in the same way as a mobile phone keypad to enter the surname, or even just the initial of the contact to call Press to send the call OK 2.1.3Using the numerical code If the resident s call code is known, simply enter it on the keypad Enter the resident code Press to send the call OK 2.2 Call to the switchboard To call the switchboard directly press this key 2.3 Door lock release using a numerical code The procedure to follow for releasing the door lock associated to the entrance panel using the lock code changes depending on the length of the codes assigned to the residents, which can be up to the maximum length set. Press the key If the length of the code is the same as the maximum length set the door lock is released 5