SPECIAL SPECIFICATION 6146 Fiber Optic RS-232 Data Modem

Similar documents
SPECIAL SPECIFICATION 6230 Fiber Optic RS-232 Data Modem

SPECIAL SPECIFICATION 6518 IP Video Codec

SPECIAL SPECIFICATION 1861 Premium Subrate Data Multiplexer and Distribution Panel

SPECIAL SPECIFICATION 6192 Hardened Ethernet Switch

SPECIAL SPECIFICATION 8143 Wireless Ethernet Radio System

SPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System

SPECIAL SPECIFICATION 6274 Microwave Vehicle Detection System

SPECIAL SPECIFICATION 8885 Wireless Ethernet Radio (Backhaul) Link

SPECIAL SPECIFICATION 1606 ISDN Compressed Video Equipment

SPECIAL SPECIFICATION 6838 Wireless Ethernet Microwave Radio

SPECIAL SPECIFICATION 1672 ISDN Compressed Video Equipment

SPECIAL SPECIFICATION 8167 Ethernet Switch

SPECIAL SPECIFICATION 6027 Lane Control Signal Equipment

SPECIAL SPECIFICATION 6325 Wireless Ethernet Microwave Radio

SPECIAL SPECIFICATION 6475 CCTV Field Equipment

SPECIAL SPECIFICATION 1826 Field Ethernet Switch

SPECIAL SPECIFICATION 8371 Field Terminal Server

SPECIAL SPECIFICATION 6025 CCTV Field Equipment

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM 6392 CCTV FIELD EQUIPMENT

SPECIAL SPECIFICATION 1528 Add/Drop Multiplexor/Demultiplexor

SPECIAL SPECIFICATION 6287 CCTV Field Equipment

SPECIAL SPECIFICATION 1986 CCTV Field Equipment

SPECIAL SPECIFICATION 8939 Retrofit Existing Fiber Optic Dynamic Message Sign System to LED

1995 Metric CSJ's & SPECIAL SPECIFICATION ITEM CCTV Field Equipment

SPECIAL SPECIFICATION 6620 Add/Drop Multiplexor

SPECIAL SPECIFICATION 1838 Computer Room VoIP Gateway/Gatekeeper

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console

SPECIAL SPECIFICATION 1252 System Control Unit Console

Special Specification 6168 Add/Drop Multiplexor

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

SPECIAL SPECIFICATION 6373 Wireless Radio Traffic Management Sites

Special Specification 6073 Model 170E Series Traffic Signal Controller, Cabinets and Related Equipment

MODIFIED SPECIAL PROVISION APPROVAL REQUEST (REV ) Date: 11/02/2015 District: 5 Type: Project Specific

Special Specification 2342 Environmentally Controlled Radio Tower Cabinet

SPECIAL SPECIFICATION 1332 Variable Message Sign Cabinet and Controller Replacement

SPECIAL SPECIFICATION 6900 LED Lane Control System

Special Specification 6082 LED Lane Control System

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

Master Hub Ethernet Switch (MHES)

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR MICROWAVE VEHICLE DETECTION SYSTEM

Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units. Reference Number SPS 30 - (RIC Standard: SC SP)

ICF-1150 Series Quick Installation Guide

MICHIGAN DEPARTMENT OF TRANSPORTATION

Special Specification 6017 Communications Hub Building

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

SPECIAL SPECIFICATION 1859 Programmable Logic Controller

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR MICROWAVE VEHICLE DETECTION SYSTEM

USER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Cabinet

DIN Molded Cable Assemblies

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

Special Specification 6016 ITS Field Equipment Cabinet

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR TRAVEL TIME SYSTEM. UNIV:SRP 1 of 6 ITS:APPR:CLC:DBP:

Data channel ports and LAN channel ports will be referred to as channel ports when distinction between the two is not required.

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

PAGE 818. The following new Section is added after Section 678. SECTION 7684 INTELLIGENT TRANSPORTATION SYSTEMS NETWORK DEVICES

DATA CONNECT ENTERPRISE

ICF-1150 Series Quick Installation Guide

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

Click Desktop Kit. Click Desktop Kit

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA)

VCL-TP, Teleprotection Equipment

CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual

Table 1. Termini Types

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

ADAM Fiber Optic to RS-232/422/485 Converter

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

SPECIAL SPECIFICATION 1303 Lifelink

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series

78 Series Electromechanical Relay Selection Guide

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

Fiber optic converter audio and CAN TA OPERATION MANUAL

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Product Performance Specifications QuadraPaddle Connector

1510 MOTOR CONTROLLERS

TOWN OF MANCHESTER GENERAL SERVICES DEPARTMENT 494 MAIN STREET P.O. BOX 191 MANCHESTER, CONNECTICUT

SPECIAL SPECIFICATION 6710 Fiber Optic Dynamic Message Sign System

SPECIFICATION FOR THE SUPPLY OF A BATTERY MONITORING SYSTEM

Precise Fiber Couple Laser Light Source

MC 11 EB-2 Power supply cabinet with external bus, AC version

Serial to Fiber Optic Converter Technical Guide

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

8520/8520R. User Manual

COOPER POWER SERIES. Fiber-optic/RS-232 communications module installation and operation instructions. Voltage Regulators MN225020EN

MED102A. Industrial Serial to Single-mode Fiber Converter

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

MLC. Semi Metal USB. Generation 5 / 5L HERCULES-PB Series. Product Specification MLC. Semi Metal USB Flash Disk Generation 5/5L

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SPECIAL SPECIFICATION Gbps ATM Switches

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

Transcription:

2004 Specifications CSJ s 0508-07-027, 0177-06-064, 0271-04-067, 0389-13-049 SPECIAL SPECIFICATION 6146 Fiber Optic RS-232 Data Modem 1. Description. Furnish and install Fiber Optic RS-232 Data Modem (FO-MODEM) in locations as shown on the plans and as detailed in the Special Specifications. A. Submittal Components. As a minimum, the submittal for this Item completely addresses the following: - optical wavelength - data rate - data input/output compatibility - unit physical size - optical input/output power and range - bit error rate - transmitting device - modulation method - optical fiber compatibility - optical detector - power requirements - transient suppression - connectors - overcurrent protection optical - environmental parameters data power gold plating 2. Material. A. General Requirements. Ensure all materials furnished, assembled, fabricated or installed under this Item are new, corrosion resistant and in strict accordance with the details shown on the plans and in the specifications. B. Functional Requirements. The FO-MODEM supports the transmission of full duplex data at true RS-232 levels on both the input and output circuits and operates over 2 single mode or 2 multimode optical fibers between specified locations as shown on the plans, as detailed in the specifications, and as directed by the Engineer. Do not adjust the FO-MODEM either in the field where the links are installed, nor periodically thereafter. C. Electrical/Optical Requirements. 1. Transmitting Device. Ensure the transmitting device for the single mode unit is a laser. An LED is the transmitting device for the multimode unit. 2. Transmitter Optical Output. Provide an output power to 8.5/125 single mode glass fiber at a wavelength of 1300 nm to accommodate a link loss budget of 15 db or more. Provide an output power to 50/125 multimode glass fiber at a wavelength of 1300 nm to accommodate a link loss budget of 13 db or more. 1-5 6146

3. Optical Detector. Provide the optical detector of the receiver to be an APD diode or Pin diode. 4. Receiver Optical Input. Ensure receiver input to have a minimum sensitivity of 15 db below the transmitter output level and operate within the parameters of this specification. 5. Transmitting/Receiving Devices. Ensure the transmitting/receiving devices has a minimum mean time between failure (MTBF) of 100,000 hours at 122ºF (50ºC) ambient. Ensure the devices incorporate diagnostic power and data activity input LED s in both the transmitter and the receiver for quick visual indication of link operation. 6. Modulation. Provide FM Modulation 7. Operating Mode. Asynchronous, full duplex. 8. Input/Output Impedance. Per RS-232. 9. System Bandwidth. DC to 19.2 Kbaud, minimum. 10. Optical Fiber Compatibility. Optical Fiber Compatibility is 8.5/125 micron single mode glass fiber or 50/125 micro multimode glass fiber as required on plans. 11. Data Performance Requirements. Ensure digital data transmitted and received by the FO-MODEM conforms to all the requirements of EIA Standard RS-232. 12. Data Rate. Ensure the FO-MODEM supports all required data transmission rates currently defined within an approved and published CCITT communication protocol standard. 13. Bit Error Rate (BER). Ensure the bit error rate of each data channel does not exceed 10 to the -9 power within optical budget. 14. Power Requirements. Ensure each FO-MODEM operates at 12 to 24 volts DC from a separate power supply to be provided as part of this bid item and does not draw more than 5 Watts of power each. Operate the separate power supply from 115 volts AC ± 10%, 60 Hz ± 3 Hz. Ensure the equipment operation is not be affected by the transient voltages, surges and sags normally experienced on commercial power lines. Ensure responsibility to check the local power service to determine if any special design is needed for the equipment. The extra cost, if required, is included in the bid of this Item. 15. Power Service Transients. Ensure the equipment meets the requirements of Section 2.1.6, Transients, Power Service, of the NEMA Standard TS1-1989, or the latest revision. 16. Wiring. Ensure all wiring meets the requirements of the National Electrical Code. Cut all wires to proper length. Provide sufficient cable slack to facilitate removal 2-5 6146

and replacement of assemblies, panels, and modules. Do not double back the wires to take up slack. Neatly lace wires into cable with nylon lacing or plastic straps. Secure cables with clamps. 17. Transient Suppression. Provide all DC relays, solenoids, and holding coils with diodes or other protective devices across the coils for transient suppression. 18. Power Service Protection. Ensure the equipment contains readily accessible, manually reset table or replaceable circuit protection devices (such as circuit breakers or fuses) for equipment and power source protection. 19. Fail Safe Provision. Design the equipment such that the failures of the equipment does not cause the failure of any other unit of equipment. D. Mechanical Requirements. 1. Modular Design. Design modular equipment to allow major portions to be readily replaced in the field. Mechanically key modules of unlike functions to prevent insertion into the wrong socket or connector. Provide all modules and assemblies to be clearly identified with name, model number, serial number and any other pertinent information required to facilitate equipment maintenance. 2. Connectors and Harnesses. Ensure all external connections are made by means of connectors. Key the connectors to preclude improper hookups. Color code and/or appropriately mark all wires to and from the connectors. Plate each and every conductive contact surface or pin with 20 microns of gold. Ensure optical input and output connectors have the FC type for the single mode units and ST type for the multimode units. Digital data inputs to and outputs from the FO-MODEM are via DB 25 connectors configured in a format compatible with the interface requirements of the data communications equipment attached. Use a connecting harness of appropriate length and terminated with matching connectors for interconnection with the terminal equipment shown on the plans, or as directed by the Engineer. E. Environmental Design Requirements. Ensure the equipment meets all its specified requirements during and after subjecting it to any combination of the following requirements: 1. Ambient temperature range of 0ºF to 140ºF. 2. Relative humidity from 0% to 95%. 3-5 6146

3. Construction Methods. A. General. Utilize equipment design and construction of the latest available techniques with a minimum number of parts, subassemblies, circuits, cards and modules to maximize standardization and commonality. Design the equipment for ease of maintenance. Ensure all component parts are readily accessible for inspection and maintenance. Provide test points for checking essential voltages and waveforms. B. Electronic Components. Ensure all electronic components comply with Special Specification, Electronic Components. C. Mechanical Components. Ensure all external screws, nuts, and locking washers are stainless steel; no self-tapping screws are used unless approved by the Engineer. Ensure all parts are made of corrosion resistant material, such as plastic, stainless steel, anodized aluminum or brass. Protect all materials used in construction from fungus growth and moisture deterioration. Separate dissimilar metals by an inert dielectric material. D. Documentation Requirements. Provide documentation requirements in accordance with the Special Specification, Testing, Training, Documentation and Warranty, Section 4. E. Testing. Perform testing in accordance with the Special Specification, Testing, Training, Documentation, Final Acceptance and Warranty, Article 2 2(6). Testing includes the following: 1. Data Performance Tests. Include all tests necessary during digital data performance testing to ensure compliance with all of the requirements of EIA Standard 232. As a minimum these tests demonstrate data communications between the transmitting equipment and the corresponding receiving equipment of each link. Using a loopback plug at each EIA-232 channel terminating at a field location, a 24 hour bit error rate test (BERT) for each channel is conducted using a data communications test set. This BERT is used to determine the bit error rate (BER) through the system and terminating equipment at each end, and to certify that the EIA-232 channels can operate at a sustained rate of 9,600 bits/sec (bps) for a 24 hour period. Use the 511-bit CCITT standard pseudo-random pattern for testing. The BER measured at 9,600 bps is not to exceed the requirements of this specification, with the error free seconds (EFS) better than 99.98%. If this BER is exceeded on any channel, correct the problem and the entire BERT will be completely restarted from the beginning, as if no previous BERT had been conducted. If a component has been modified as a result of the subsystem test failure, prepare a report and deliver it to the Engineer prior to testing. Ensure to supply all required test equipment. 4-5 6146

F. Training. Provide training in accordance with Special Specification, Testing, Training, Documentation, Final Acceptance and Warranty, Article 3. G. Warranty. Provide a warranty in accordance with the Special Specification, Testing, Training, Documentation, Final Acceptance and Warranty, Article 6. 4. Measurement. This Item is measured as each unit furnished, installed, made fully operational and tested in accordance with these Special Specifications or as directed by the Engineer. 5. Payment. The work performed and materials furnished in accordance with this Item and measured as provided under Measurement are paid for at the unit prices bid for Fiber Optic RS-232 Data Modem (Single Mode) or Fiber Optic RS-232 Data Modem (Multimode). This price includes all equipment described under this Item with all cables and connectors, all documentation and testing and the cost of furnishing all labor, materials, training, warranty, equipment, and incidentals necessary to complete the work. 5-5 6146