1 GeneMapper ID-X Software Version 1.2 USER BULLETIN DECEMBER 2010 SUBJECT: Verification Experiments and Installation Procedures Purpose of this user bulletin In this user bulletin This user bulletin: Describes the results of experiments performed by Life Technologies to verify the following: The GeneMapper ID-X Software Version 1.2 performs as designed to analyze data generated on legacy human identification capillary electrophoresis platforms such as the ABI PRISM 310, 3100, 3100-Avant, 3130, and 3130xl Genetic Analyzers, and the 3730 DNA Analyzer. The new features added do not adversely affect the software functionality carried over from GeneMapper ID-X Software Version Provides instructions for installing GeneMapper ID-X Software Version 1.2. This user bulletin covers: About GeneMapper ID-X Software Version Verification Software verification testing and results Sizing and genotyping concordance Mixture analysis Results Conclusions Installing GeneMapper ID-X Software Version General installation instructions About co-installation with Data Collection Software Perform a fresh GeneMapper ID-X Software Version 1.2 installation Upgrade from a previous version Troubleshooting Obtaining support

2 About GeneMapper ID-X Software Version 1.2 About GeneMapper ID-X Software Version 1.2 GeneMapper ID-X Software Version 1.2 contains the same functionality as GeneMapper ID-X Software Version 1.1.1, with additional capability to analyze.hid sample files generated on the 3500 and 3500xL Genetic Analyzers. Features incorporated from v1.1.1 software include: An option to separate each sample plot and table on individual pages when printing multiple samples at a time An option to enable/disable spike detection for allelic ladder samples Enhancements to printing speed to decrease total print time and increase print speed per page The full list of features incorporated from version are described in more detail in the GeneMapper ID-X Software Version User Bulletin (PN ), which is available to view or download at: applied_markets_support/documents/generaldocuments/cms_ pdf New features in version 1.2 software include: The ability to analyze.hid sample files generated on the 3500 and 3500xL Genetic Analyzers and view additional sample file information The ability to enable/disable the normalization of sample peaks when the normalization feature is enabled in 3500 and 3500xL Data Collection Software Compatibility with Windows Vista in addition to Windows XP and Windows 2000 Professional Operating Systems Updated database to the newest Oracle 11G database Verification Software verification testing and results The tests performed in this validation include the following: Concordance testing comparing a historical data set collected from legacy Genetic Analyzer instruments using a variety of AmpFlSTR kits analyzed using GeneMapper ID-X Software versions 1.1 and 1.2 (compare data in Genotypes and Sizing tables). Concordance testing comparing mixture analysis results generated from a historical mixture data set on the 3130xl Genetic Analyzer, using existing AmpFlSTR kits and analyzed using GeneMapper ID-X Software version 1.1 and 1.2. Verification of features carried over into GeneMapper ID-X Software Version 1.2 from GeneMapper ID-X Software version including: Adjustment of profile-comparison match-filtering to correct an issue where some matches were not properly displayed Update to correct marker name sorting in the profile comparison display Changes to the CODIS export file format to remove the registered trademark which could not be translated by Chinese operating systems Changes to the CODIS export file format to display September in 3 character format (SEP) The option to turn allelic ladder spike detection on or off 2 GeneMapper ID-X Software Version 1.2 User Bulletin

3 Verification Update to the local southern sizing algorithm to address a rarely observed issue with GeneScan 600 LIZ Size Standard, in which size standard fragments form a perfect line resulting in incorrect plot display and abnormal peak morphology Address an issue where modifications to the size standard or analysis method do not get exported when the project is exported (if the project is not re-analyzed) The test cases performed in this verification study and the passing criteria are summarized in Table 2 on page 5. A summary of the verification study tests and results is shown in Table 3 on page 7. Sizing and genotyping concordance A total of 2204.fsa sample files were used in the concordance test. The sources and types of samples are listed in Table 1 on page 4. GeneMapper ID-X Software Version 1.2 User Bulletin 3

4 4 GeneMapper ID-X Software Version 1.2 User Bulletin:Verification Experiments and Installation Procedures Table 1 Number of sample files by type used in concordance testing. The capillary electrophoresis instrument, data collection software version, and AmpFlSTR kit used to generate data are noted. Instrument/ Data Collection Software ABI PRISM 310 Genetic Analyzer DC Software v3.0/ Genetic Analyzer DC Software v1.1/ Avant Genetic Analyzer DC Software v xl Genetic Analyzer DC Software v Genetic Analyzer; DC Software v3.0 AmpFlSTR Kit Single Source Sensitivity Mixture Low Quality DNA LOR OMR Spike Good Ladder Low Quality Ladder Positive Negative Total COfiler Profiler Plus Identifiler SGM Plus SEfiler Yfiler MiniFiler COfiler Profiler Plus Identifiler SGM Plus SEfiler COfiler Profiler Plus Identifiler Profiler Plus Identifiler SGM Plus SEfiler Yfiler MiniFiler Sinofiler Identifiler Total Verification Experiments and Installation Procedures Verification

5 Verification The data listed in Table 1 were analyzed using both GeneMapper ID-X Software versions 1.1 and 1.2. The Genotypes and Sizing tables were exported and compared using Beyond Compare Software version to determine whether any differences in data output resulted. The peak heights, peak areas, data points, sizes, allele names, and all the PQV scores were compared between the two software versions. Mixture analysis A historical mixture sample data set was used to validate the concordance of the mixture analysis results between the GeneMapper ID-X Software versions 1.1 and 1.2. The data set included 2-contributor mixtures made from 8 pairs of genomic DNA samples prepared in 11 mixture ratios: 1:0, 1:1, 1:2, 1:3, 1:5, 1:9, 9:1, 5:1, 3:1, 2:1, and 0:1. The mixture samples were amplified with the AmpFlSTR Identifiler (1 ng and ng), Profiler Plus, COfiler, and SGM Plus PCR Amplification kits. The samples were analyzed on two 3130xl instruments. 476 sample files were used to test Mixture Interpretation Threshold (MIT) pruning and sample segregation; 287 sample files were used to compare pattern extraction; 31 sample files were used to test Random Match Probability (RMP), Combined Probability of Inclusion/Exclusion (CPI/ CPE), and Likelihood Ratio (LR) calculations; 24 sample files were used for known matching; 4 pairs of sample files were used to test multiple kit merging. Table 2 Verification test cases The following mixture analysis log files or exported files in.txt format were generated on both versions of the software with the exact same population databases, MIT and PHR thresholds, theta values, LR hypotheses, and conclusive options: SampleClassification_Log for MIT pruning and sample segregation. MixtureSamples and MixtureSamples (analysis log) for pattern extraction, PHR, residual, Mx and Avg Mx calculation, as well as UI flags and values. MixtureSampleStatsCalc_Log for RMP, CPI, and known matching calculations. Individual MAData export files for RMP, CPI, LR, and multiple kit merging calculations. These text files were compared using the Beyond Compare Software v The comparison tool lined up the text files from the two software versions, and compared the file contents for concordance. Tested Cases Test Description Passing Criteria CODIS export removal of registered trademark CODIS export date format Profile Comparison Match Display Profile Comparison Marker Order Display Perform analysis of 10 single-source samples. After genotyping analysis, export the CODIS tables. Perform analysis of 10 single-source samples from projects created in September After genotyping analysis, export the CODIS tables. Using a project displaying the issue, set the percent match threshold to 90%, 80%, and 70%. Check the accuracy of the profile match filtering. Select one mixture sample set each from Identifiler, Profiler Plus, SGM Plus, and COfiler kit data with mixture ratios of 0:1, 1:1, 1:3, 1:5, 1:9, and 1:0. Set the percent-match threshold to 90%, 80%, and 70%. Check the accuracy of the matching entry filtering. Using test data above, verify matching entries displayed in the same marker order. Verify the registered trademark is removed in CODIS export file. Verify September date is displayed as SEP. Verify all matches correctly displayed at each match threshold. Verify all matches correctly displayed with marker order sorted by dye color and size. GeneMapper ID-X Software Version 1.2 User Bulletin 5

6 Verification Tested Cases Test Description Passing Criteria Modified Size Standard/ Analysis Method Export Size Calling Issue Y-scale Display Print Individual Sample Followed by Page Break Disable Spike Detection for Allelic Ladders Select 3 single-source samples from a previously analyzed project. Modify the size standard by adding or deleting one or more peaks and click OK to save. Without re-analyzing the data, export the project and delete the project from GeneMapper Manager. Reimport the project, open it, verify that the changed size standard settings are persisted. Select 3 single-source samples from a previously analyzed project. Modify the Analysis Method by changing any of the parameters and save. Without reanalyzing the data, export the project and delete the project from GeneMapper Manager. Re-import the project, open it and verify that the changed Analysis Method settings are persisted. Using a project displaying the issue, verify the issue is corrected. Select 5 single-source samples from previously analyzed projects, including data generated on the 3730 with GS600, 31xx with GS500LIZ and 31xx with GS500ROX. Re-analyze the data to verify no changes happened due to this update. Perform analysis of 10 single-source samples. After genotyping analysis, zoom in on the y-scale of each sample to view the y-scale values. Print the electropherograms. Perform analysis of 10 single-source samples. After genotyping analysis, print the profiles and genotype tables with the page break. Perform analysis of 10 single-source samples and 10 allelic ladders containing spikes. Genotype the data with the spike detection for allelic ladder enabled and disabled. Compare the allele calls, sizing, and PQV results. Verify that size standard changes are persisted and can be exported with the project. Verify that analysis method changes are persisted and can be exported with the project. Verify that the issue is corrected for a sample that was previously affected. Verify that all remaining data were correct and unaffected by the update. Verify that the Y-scale is printed according to the plot settings. Verify the page break is inserted properly. Verify that spikes are not detected in allelic ladders when the spike detection option is disabled. Verify that spikes are detected in allelic ladders when the spike detection option is enabled. Verify that spikes are detected in samples when the Allelic Ladder spike detection option is enabled and disabled. 6 GeneMapper ID-X Software Version 1.2 User Bulletin

7 Verification Table 3 Summary of verification testing results Testing Categories Subcategories Expected Outcome Result Concordance with GMID-X v1.1 Genotyping Allele calls 100% concordant, with ladder spike detection on. Peak Detection Size, height, area, and data point 100% concordant. Pass PQVs With the ladder spike detection on, all the PQV scores, including SQ values, shall be 100% concordant. With the ladder spike detection off, the relevant PQV scores are expected to have discrepancies. Pass Pass Mixture Analysis All the mixture analysis calculations and flags shall be 100% concordant using the same analysis method and thresholds. Pass Verification of patch updates Profile Comparison Incorrect Result The % match filter shall generate correct result all matching entries shall be displayed when the match threshold is adjusted. Pass Profile Comparison Sorting of Marker The markers shall be sorted consistently across the samples in the Profile Comparison view, first by dye then by the size order. Pass CODIS Export - Date Format Issue For CODIS export, all months shall be three letters. The September shall show up as SEP. Pass CODIS Export - Registered Mark Issue In the CODIS export, the registered trademark in the software name shall be removed. Pass Start a New Page to Print for each Sample With the option to insert a page break after each individual sample plot, the printout will show that each sample is printed starting on a new page, even though one sample may overflow to multiple pages. Pass Results All metrics were met as described above and only one result of note was identified. In one specific case, a labeling difference was found between the two software versions in the size plot and table. This instance involved one AmpFlSTR Sinofiler kit allelic ladder sample which was deemed to be low-quality due to poor resolution (broad peaks). Due to a broad peak, the 19.3 and 20 alleles in the D12 marker were labeled as a single 19.3 allele and, in GeneMapper ID-X Software version 1.1, shifted every subsequent peak to the right. This resulted in labeling the first peak (allele 7) in D18 as the last peak (allele 27) in D12. The OVL warning was properly triggered and the Genotype Quality flag for the D12 marker was red, indicating that the ladder failed. GeneMapper ID-X Software Version 1.2 User Bulletin 7

8 Verification Two issues were observed: 1. In both v1.1 and v1.2 software, labeling of the first D18 peak in the sample plot was not consistent with the allele name in the size table. 2. Labeling of the first D18 peak in the sample plot was different between v1.1 and v1.2 software. In v1.1 software: The allele designation was 7 in the sizing table The allele designation was 27 in the sample plot When the peak in the sample plot was highlighted, the D18 row in the sizing table was selected In v1.2 software: The allele designation was 27 in the sizing table The allele designation in the sample plot was 7 When the peak in the sample plot was highlighted, the D12 row in the sizing table was selected In all cases, the contents of the genotypes table from v1.1 and v1.2 match each other. This issue was not observed with any allelic ladders that passed all quality metrics. Conclusions The GeneMapper ID-X Software Version 1.2 can be used to process.fsa files generated on legacy capillary electrophoresis instruments and with existing AmpFlSTR kits. The same results for sizing, genotyping, and mixture analysis were obtained using GeneMapper ID-X Software versions 1.1 and 1.2. All updates to GeneMapper ID-X Software Version 1.2 were successfully and correctly implemented without deleterious effects on other software functionality. A difference in handling overlapping marker data was observed between the two software versions in one instance of a low-quality Sinofiler kit allelic ladder. Based on the nature of the modifications addressed in this update, and the testing that we performed, it is recommended that users evaluate this software as appropriate for their laboratory workflow to demonstrate concordance to previously validated GeneMapper ID-X Software versions. Laboratories should determine the appropriate level of testing required based on their internal software validation guidelines and those of the appropriate governing agencies. 8 GeneMapper ID-X Software Version 1.2 User Bulletin

9 Installing GeneMapper ID-X Software Version 1.2 Installing GeneMapper ID-X Software Version 1.2 General installation instructions About coinstallation with Data Collection Software Perform a fresh GeneMapper ID-X Software Version 1.2 installation Before installing the GeneMapper ID-X Software Version 1.2, review the GeneMapper ID-X Software Version 1.2 Installation Guide and any supplemental documentation. General guidance to ensure successful GeneMapper ID-X Software Version 1.2 installation or upgrade from previous GeneMapper ID-X Software versions includes: Computer with 1 GB or higher memory is highly recommended Computer virtual memory should be set at Custom Size ( MB) before software installation or upgrade User must log in to the local computer and have Administrator privileges when installing, un-installing, or upgrading the GeneMapper ID-X Software Version 1.2 When un-installing the GeneMapper ID-X Software, the user should log in using the same user name as the one used when installing the software to ensure clean un-installation. User must follow the un-installation message prompts during uninstallation process. When performing an upgrade on a stand-alone computer, use the Add/Remove Program feature in Microsoft Windows to un-install the previous version of GeneMapper ID-X Software Computers with both GeneMapper ID-X Software Version 1.2 and Data Collection Software installed (referred to as a co-installation ) should not be used as the host computer for other clients. Such host computers can only connect to one client computer. When GeneMapper ID-X Software Version 1.2 is not co-installed with Data Collection Software, remote autoanalysis is supported for the 31xx platform, but not for the 3500/3500xL and 310 platforms. Use the GeneMapper ID-X v1.2 Full or Client installation CD for fresh installations or installations to computers installed with GeneMapper ID Software v3.2. A detailed description of different fresh installation scenarios and steps performed by the user is summarized in Table 4 on pages 10 and 11. GeneMapper ID-X Software Version 1.2 User Bulletin 9

10 10 GeneMapper ID-X Software Version 1.2 User Bulletin:Verification Experiments and Installation Procedures Table 4 Fresh installation scenarios and steps Installation Type GeneMapper ID-X Software Version 1.2 Full installation GeneMapper ID-X Software Version 1.2 Full fresh installation GeneMapper ID-X Software Version 1.2 Full installation to a computer installed with GeneMapper ID Software v3.2 Scenario Choose CD Steps Stand Alone Computer without any version of GeneMapper ID-X Software or Data Collection Software installed Co-Install to a computer with Data Collection Software installed # Stand Alone Computer with GeneMapper ID Software v3.2 Co-Install to a computer with GeneMapper ID Software v3.2 and Data Collection Software installed # GeneMapper ID-X v1.2 Full PN Log on to the local computer to an account with Administrator privileges. 2. Insert the CD and follow the instructions. Installation takes about 1 hour to complete. 3. Enter the Registration Code to launch the software. 1. Log on to the local computer to an account with Administrator privileges. 2. Insert the CD and follow the instructions. The software detects the GeneMapper ID Software v3.x. 3. Export the data objects (projects, analysis methods, etc.) 4. Uninstall the GeneMapper ID Software v3.2 (Remove Program). 5. Restart the computer, then log on to the local computer to an account with Administrator privileges. 6. Install the GeneMapper ID-X Software v1.2 Full. 7. Enter the Registration Code to launch the software. Verification Experiments and Installation Procedures Installing GeneMapper ID-X Software Version 1.2

11 GeneMapper ID-X Software Version 1.2 User Bulletin:Verification Experiments and Installation Procedures 11 Installation Type GeneMapper ID-X Software Version 1.2 Client installation Fresh client installation Fresh installation to a computer with GeneMapper ID Software v3.2 Scenario Choose CD Steps Stand Alone Computer without any version of GeneMapper ID-X Software installed Co-Install to a computer with Data Collection Software installed # Stand Alone Computer with GMID v3.2 installed Co-Install to a computer with GeneMapper ID Software v3.2 and Data Collection Software installed GeneMapper ID-X v1.2 Client PN Log on to the local computer to an account with Administrator privileges. 2. Insert the CD and follow the instructions. Installation takes about 15 minutes to complete. 3. Enter the Registration Code to launch the software. 1. Log on to the local computer to an account with Administrator privileges. 2. Insert the CD and follow the instructions. The software detects the GeneMapper ID Software v3.x. The installation stops because GeneMapper ID-X v1.2 Client version does not have an export utility. 3. Insert a GeneMapper ID-X v1.2 full version CD to export the data objects (projects, analysis methods, etc.). 4. Uninstall the GeneMapper ID Software v3.2 (Remove Program). 5. Restart the computer, then log on to the local computer to an account with Administrator privileges. 6. Install the GeneMapper ID-X Software v1.2 Client. 7. Enter the registration code to launch the software. In order to use the Client version, a GeneMapper ID-X Software Version 1.2 Full version must be installed on another computer first. If GeneMapper ID Software v3.1 is installed on the computer, uninstall v3.1 or upgrade to GeneMapper ID v3.2 before installing GeneMapper ID-X Software Version 1.2. # GeneMapper ID-X Software Version 1.2 can be co-installed with legacy Data Collection Software v2.0 and 3.0, 3500 Data Collection Software on Windows XP OS, or on 3500 Data Collection Software on Windows Vista OS. However, co-installation with 3500 Data Collection Software is not recommended. Verification Experiments and Installation Procedures Installing GeneMapper ID-X Software Version 1.2

12 Installing GeneMapper ID-X Software Version 1.2 Upgrade from a previous version GeneMapper ID-X Software versions 1.0, 1.0.1, 1.1, and can be upgraded to GeneMapper ID-X Software Version 1.2 by using the GeneMapper ID-X Software Version 1.2 Full Upgrade or Client Upgrade CD. Table 5 Upgrade scenarios and steps 1. Before upgrading the software, back up all GeneMapper ID-X Software project data and results, close all instances of previous versions of GeneMapper ID-X Software (on both Client and Full computers), and close all other software programs and open windows. 2. During the installation of GeneMapper ID-X Software Version 1.2 (in both fresh installation and software upgrade cases): a. Install the GeneMapper ID-X Software Version 1.2 on the Full version first and then on all Client versions which will connect to the Full version database. b. Allow the CD to Autostart, or double-click the Setup.exe file to launch the installer. 3. After the software upgrade, enter the registration code obtained with the previous software version to launch the software. The data analyzed from previous GeneMapper ID-X Software versions can be imported and viewed in GeneMapper ID-X Software Version 1.2. A detailed description of different upgrade scenarios and steps performed by the user is summarized in Table 5. Installation Type Scenario Choose CD Steps Upgrade to GeneMapper ID-X Software Version 1.2 Full Upgrade GeneMapper ID-X Software v1.0, 1.0.1, or 1.1 Full installed on a stand-alone computer GeneMapper ID-X v1.2 Full Upgrade PN Log on to the local computer to an account with Administrator privileges. 2. Export the data objects (projects, analysis methods, etc.) 3. Uninstall the previous version of GeneMapper ID-X Software (Remove Program). 4. Restart the computer, then log on to the local computer to an account with Administrator privileges. 5. Insert the CD. 6. Install the GeneMapper ID-X Software v1.2 Full Upgrade. 7. Enter the Registration Code from the previous version to launch the software. Upgrade GeneMapper ID-X Software v1.0, 1.0.1, or 1.1 co-installed with Data Collection Software 1. Log on to the local computer to an account with Administrator privileges. 2. Insert the CD and follow the instructions. 3. Enter the Registration Code from the previous version to launch the software. 12 GeneMapper ID-X Software Version 1.2 User Bulletin

13 Installing GeneMapper ID-X Software Version 1.2 Installation Type Scenario Choose CD Steps Upgrade to GeneMapper ID-X Software Version 1.2 Client Upgrade GeneMapper ID-X Software v1.0, 1.0.1, or 1.1 Client installed on a stand-alone computer Upgrade GeneMapper ID-X Software v1.0, 1.0.1, or 1.1 Client co-installed with Data Collection Software GeneMapper ID-X v1.2 Client Upgrade PN Log on to the local computer to an account with Administrator privileges. 2. Insert the CD and follow the instructions. The software detects the previous version of GeneMapper ID-X Software. 3. Enter the Registration Code from the previous version to launch the software. In order to use the Client version, a GeneMapper ID-X Software Version 1.2 Full version must be installed on another computer first. Please note: Upgrade all instances of previous versions of the GeneMapper ID-X Software, including both GeneMapper ID-X Software Client and Full versions before launching the GeneMapper ID-X Software Version 1.2. Depending on your computer configuration, you may be able to directly upgrade the previous version of GeneMapper ID-X Software to version 1.2, or you may need to completely uninstall the previous version before installing version 1.2. For Full installations of v1.2, you must manually uninstall any previous versions. For Client versions of v1.2, the installer software automatically performs the upgrade when you insert the version 1.2 CD. If the GeneMapper ID-X Software is installed on a computer platform that has not been validated by Applied Biosystems/Life Technologies, you may experience difficulties during the software upgrade. Please review the list of recommended software operating systems before beginning installation, and report any issues encountered during installation to your local Human Identification support specialist. Troubleshooting Setup.exe errors during software installation If you see the following error message, or any setup.exe error, when you install the software, the virtual memory settings of your Windows operating system are insufficient and need to be adjusted as follows: 1. Close the error message window and let the installation finish, then uninstall the software using Add/Remove programs. 2. After uninstallation, adjust the virtual memory settings: a. Right-click My Computer, then select Properties. b. In the System Properties dialog, select the Advanced tab, then select Performance Settings. GeneMapper ID-X Software Version 1.2 User Bulletin 13

14 Installing GeneMapper ID-X Software Version 1.2 c. In the Performance Options dialog, select the Advanced tab, then select Virtual memory Change. d. Select the drive that contains the Windows operating systems (usually the C: drive), then select Custom size. Enter 2046 MB for Initial size and 4092 for Maximum size. Note: For some systems, any values larger than 500 MB may be sufficient. e. Click Set, click OK, then click Apply. 3. Restart the computer, then return to the Virtual Memory dialog and confirm that the Paging File Size is set for the drive that contains the Windows operating system (usually the C: drive). 4. Install the GeneMapper ID-X Software Version 1.2. Note: If you receive an error at this stage indicating that Oracle is found on the system, delete the X:\AppliedBiosystems\OracleGMIDX folder, restart the system, then attempt another install. In more severe cases, you may need to run the RemoveOracle.exe program found on the installation CD in the Tools folder. 14 GeneMapper ID-X Software Version 1.2 User Bulletin

15 Installing GeneMapper ID-X Software Version 1.2 Obtaining support For HID support: In the United States and Canada send an to or call option 1. Outside the United States and Canada contact your local support office. For the latest services and support information for all locations, go to: At the Applied Biosystems web site, you can: Access worldwide telephone and fax numbers to contact Applied Biosystems Technical Support and Sales facilities. Search through frequently asked questions (FAQs). Submit a question directly to Technical Support. Order Applied Biosystems user documents, SDSs, certificates of analysis, and other related documents. Download PDF documents. Obtain information about customer training. Download software updates and patches. GeneMapper ID-X Software Version 1.2 User Bulletin 15

16 For Research, Forensic, or Paternity Use Only. Not intended for any animal or human therapeutic or diagnostic use. Information in this document is subject to change without notice. APPLIED BIOSYSTEMS DISCLAIMS ALL WARRANTIES WITH RESPECT TO THIS DOCUMENT, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TO THE FULLEST EXTENT ALLOWED BY LAW, IN NO EVENT SHALL APPLIED BIOSYSTEMS BE LIABLE, WHETHER IN CONTRACT, TORT, WARRANTY, OR UNDER ANY STATUTE OR ON ANY OTHER BASIS FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING FROM THIS DOCUMENT, INCLUDING BUT NOT LIMITED TO THE USE THEREOF, WHETHER OR NOT FORESEEABLE AND WHETHER OR NOT APPLIED BIOSYSTEMS IS ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Purchase of this software product alone does not imply any license under any process, instrument or other apparatus, system, composition, reagent or kit rights owned or otherwise controlled by Life Technologies, either expressly, or by estoppel. Not for re-sale. THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF APPLIED BIOSYSTEMS AND IS TO BE RETAINED IN CONFIDENCE, NOT TO BE REPRODUCED, COPIED, OR INCORPORATED IN ANY MANNER Life Technologies Corporation. All rights reserved. The trademarks mentioned herein are the property of Life Technologies Corporation or their respective owners. Beyond Compare is a trademark of Scooter Software Inc. Windows Vista and Windows are trademarks of Microsoft Corporation. Part Number Rev. A 12/2010 Headquarters 5791 Van Allen Way Carlsbad, CA USA Phone Technical Resources and Support For the latest technical resources and support information for all locations, please refer to our Web site at

User Bulletin. GeneMapper ID-X Software Version Update. GeneMapper ID-X Software Version Verification. In this user bulletin.

User Bulletin. GeneMapper ID-X Software Version Update. GeneMapper ID-X Software Version Verification. In this user bulletin. User Bulletin GeneMapper ID-X Software Version 1.1.1 Update October 2009 SUBJECT: GeneMapper ID-X Software Version 1.1.1 Verification In this user bulletin Overview This user bulletin covers: Overview......................................................

More information

GeneMapper ID-X Software

GeneMapper ID-X Software Quick Reference Guide GeneMapper ID-X Software Version 1.0 Overview GeneMapper ID-X Software Version 1.0 is an automated genotyping software solution for all human identification (HID) data analysis needs,

More information

User Bulletin. GeneMapper ID Software v3.2.1 Patch. In This User Bulletin. Obtaining and Installing the GeneMapper ID Software v3.2.

User Bulletin. GeneMapper ID Software v3.2.1 Patch. In This User Bulletin. Obtaining and Installing the GeneMapper ID Software v3.2. User Bulletin GeneMapper ID Software v3.2.1 Patch 01/2007 SUBJECT: GeneMapper ID Software v3.2.1 Patch In This User Bulletin This user bulletin provides information about four minor changes provided in

More information

User Bulletin. GeneMapper Software Version 4.1. In This User Bulletin. Overview This user bulletin supplements the GeneMapper Software v4.

User Bulletin. GeneMapper Software Version 4.1. In This User Bulletin. Overview This user bulletin supplements the GeneMapper Software v4. User Bulletin GeneMapper Software Version 4.1 April 2009 SUBJECT: Autoanalysis In This User Bulletin This user bulletin covers: Autoanalysis Using GeneMapper Software v4.1.............. 2 Autoanalysis

More information

GeneMapper Software v3.5

GeneMapper Software v3.5 GeneMapper Software v3.5 Installation Instructions This document includes: Before You Install v3.5................................... 2 Installing the Instrument Configuration...................... 6 Installing

More information

Installing the GeneMapper Software and Creating a Matrix on the ABI PRISM 310 Genetic Analyzer

Installing the GeneMapper Software and Creating a Matrix on the ABI PRISM 310 Genetic Analyzer User Bulletin GeneMapper Software Version 4.0 and Version 3.7 September 2005 SUBJECT: Installing the GeneMapper Software and Creating a Matrix on the ABI PRISM 310 Genetic Analyzer In This User Bulletin

More information

Applied Biosystems TrueScience Aneuploidy STR Kits

Applied Biosystems TrueScience Aneuploidy STR Kits Applied Biosystems TrueScience Aneuploidy STR Kits Software Setup and Data Analysis User Guide The results obtained from these or any other diagnostic kits should be used and interpreted only in the context

More information

User Bulletin. ABI PRISM 310 Genetic Analyzer. DRAFT February 6, :09 pm, A.fm. G5v2 Module for Use with Dye Set 33 (DS-33)

User Bulletin. ABI PRISM 310 Genetic Analyzer. DRAFT February 6, :09 pm, A.fm. G5v2 Module for Use with Dye Set 33 (DS-33) User Bulletin ABI PRISM 310 Genetic Analyzer Issue Date 2/06/03 SUBJECT: G5v2 Module for Use with Dye Set 33 (DS-33) In This User Bulletin Overview This user bulletin describes how to install the for the

More information

Configuring GeneMapper ID Software

Configuring GeneMapper ID Software Configuring GeneMapper ID Software using Advanced algorithm analysis Importing the Panels and Bins In order to successfully genotype AmpFlSTR kit samples, the panels and bins must be imported. The panels

More information

RELEASE NOTES TABLE OF CONTENTS SOFTWARE OVERVIEW

RELEASE NOTES TABLE OF CONTENTS SOFTWARE OVERVIEW RELEASE NOTES GeneMapper TM ID-X Software v1.5.2 Life Technologies is a Thermo Fisher Scientific brand. 2016 Thermo Fisher Scientific Inc. All rights reserved October 2016 TABLE OF CONTENTS * Software

More information

User Bulletin. 3730/3730xl DNA Analyzer Data Collection Software. New features. SUBJECT: Data Collection Software version 3.1. In this user bulletin

User Bulletin. 3730/3730xl DNA Analyzer Data Collection Software. New features. SUBJECT: Data Collection Software version 3.1. In this user bulletin User Bulletin 3730/3730xl DNA Analyzer Data Collection Software May 2009 SUBJECT: Data Collection Software version 3.1 In this user bulletin This user bulletin covers: New features....................................................1

More information

ABI PRISM GeneMapper Software Version 3.0 SNP Genotyping

ABI PRISM GeneMapper Software Version 3.0 SNP Genotyping ABI PRISM GeneMapper Software Version 3.0 SNP Genotyping Tutorial ABI PRISM GeneMapper Software Version 3.0 SNP Genotyping Tutorial September 25, 2002 1:20 pm, 7x9_Title.fm Copyright 2002, Applied Biosystems.

More information

Procedure for GeneMapper ID. 1.0 Purpose To specify the steps for performing analysis on DNA samples using GeneMapper ID (GMID) software.

Procedure for GeneMapper ID. 1.0 Purpose To specify the steps for performing analysis on DNA samples using GeneMapper ID (GMID) software. Procedure for GeneMapper ID 1.0 Purpose To specify the steps for performing analysis on DNA samples using GeneMapper ID (GMID) software. 2.0 Scope This procedure applies to DNA Database Forensic Scientists

More information

User Bulletin Applied Biosystems StepOne /StepOnePlus Real-Time PCR System

User Bulletin Applied Biosystems StepOne /StepOnePlus Real-Time PCR System User Bulletin Applied Biosystems StepOne /StepOnePlus Real-Time PCR System July 30, 2007 SUBJECT: Network Port Calibration and StepOne Instrument Connection Procedures In This User Bulletin How to Check

More information

About Data Collection Preferences. Before You Begin. Macintosh computer - Step One: Setting Folder Locations

About Data Collection Preferences. Before You Begin. Macintosh computer - Step One: Setting Folder Locations To navigate within this document use the or keys ABI PRISM 310 Genetic Analyzer Data Collection Software Preferences Module Macintosh computer BEFORE PERFORMING ANY TROUBLESHOOTING WORK ON YOUR ABI PRISM

More information

Release Notes QuantStudio 3D Software v 3.0

Release Notes QuantStudio 3D Software v 3.0 CONTENTS OVERVIEW FEATURES KNOWN ISSUES LICENSE DOWNLOAD SOFTWARE INSTALL SOFTWARE LEGAL STATEMENTS Release Notes QuantStudio 3D Software v 3.0 OVERVIEW QuantStudio 3D Software supports the Applied Biosystems

More information

SequencePro Data Analysis Application. User Guide

SequencePro Data Analysis Application. User Guide SequencePro Data Analysis Application User Guide SequencePro Data Analysis Application User Guide DRAFT October 31, 2001 12:52 pm, Title_page.fm Copyright 2001, Applied Biosystems. All rights reserved.

More information

User Bulletin. ABI PRISM GeneScan Analysis Software for the Windows NT Operating System. Introduction DRAFT

User Bulletin. ABI PRISM GeneScan Analysis Software for the Windows NT Operating System. Introduction DRAFT User Bulletin ABI PRISM GeneScan Analysis Software for the Windows NT Operating System SUBJECT: June 2002 Overview of the Analysis Parameters and Size Caller Introduction In This User Bulletin Purpose

More information

Use the AccuSEQ Software v2.0 Custom Experiment mode

Use the AccuSEQ Software v2.0 Custom Experiment mode QUICK REFERENCE Use the AccuSEQ Software v2.0 Custom Experiment mode Publication Part Number 4425585 Revision Date 25 January 2013 (Rev. B) Custom Experiments Note: For safety and biohazard guidelines,

More information

Next generation Confirmation (NGC) module

Next generation Confirmation (NGC) module QUICK REFERENCE Next generation Confirmation (NGC) module Catalog Number A28221 Pub. No. MAN0015891 Rev. A.0 Product description The Applied Biosystems Next generation Confirmation (NGC) module analyzes

More information

Demonstrated Protocol: How to Set Up the Ion OneTouch 2 Instrument When Switching Between the Ion PGM System and Ion Proton System

Demonstrated Protocol: How to Set Up the Ion OneTouch 2 Instrument When Switching Between the Ion PGM System and Ion Proton System USER BULLETIN Demonstrated Protocol: How to Set Up the Ion OneTouch 2 Instrument When Switching Between the Ion PGM System and Ion Proton System Publication Number MAN0007719 Revision 2.0 Overview.............................................................

More information

ABI PRISM 3100-Avant and 3100 Data Collection v2.0 Software Frequently Asked Questions (FAQ)

ABI PRISM 3100-Avant and 3100 Data Collection v2.0 Software Frequently Asked Questions (FAQ) ABI PRISM 3100-Avant and 3100 Data Collection v2.0 Software Frequently Asked Questions (FAQ) Table of Contents General Information...2 Access Control/Auditing Features...2 Instrument/Plate Setup...3 Spectral

More information

ABI PRISM GeneMapper Software Version 3.0. User s Manual

ABI PRISM GeneMapper Software Version 3.0. User s Manual ABI PRISM GeneMapper Software Version 3.0 User s Manual Copyright 2002, Applied Biosystems. All rights reserved. For Research Use Only. Not for use in diagnostic procedures. Information in this document

More information

MicroSeq ID Analysis Software Version 1.0

MicroSeq ID Analysis Software Version 1.0 MicroSeq ID Analysis Software Version 1.0 Getting Started Guide Copyright 2003, Applied Biosystems. All rights reserved. For Research Use Only. Not for use in diagnostic procedures. Information in this

More information

Getting Started Guide. HID Real-Time PCR Analysis Software Version 1.0 For 7500 Real-Time PCR System

Getting Started Guide. HID Real-Time PCR Analysis Software Version 1.0 For 7500 Real-Time PCR System Getting Started Guide HID Real-Time PCR Analysis Software Version 1.0 For 7500 Real-Time PCR System Getting Started Guide Get Started HID Real-Time PCR Analysis Software Version 1.0 For 7500 Real-Time

More information

Devyser QF-PCR. Guide to Sample Runs, Data Analysis & Results Interpretation

Devyser QF-PCR. Guide to Sample Runs, Data Analysis & Results Interpretation Devyser QF-PCR Guide to Sample Runs, Data Analysis & Results Interpretation Version 4-2013 Contents 1. Setting up a sample run on an ABI Genetic Analyzer... 3 1.1 Introduction... 3 1.2 Workflow... 3 1.3

More information

Applied Biosystems RapidFinder Software Version 1.0 and SDS Software Version Beta Release 10/05 Release Notes (PN Rev A)

Applied Biosystems RapidFinder Software Version 1.0 and SDS Software Version Beta Release 10/05 Release Notes (PN Rev A) Applied Biosystems RapidFinder Software Version 1.0 and SDS Software Version 1.3.2 Beta Release 10/05 Release Notes (PN 4370225 Rev A) Software Release notes for: Applied Biosystems RapidFinder Software

More information

You will see the difference!

You will see the difference! NDIS Approved Expert System Fast, Accurate, and User-friendly ~ Documented time savings of up to 40%1 ~ Up to 70% less analyst intervention2 User Management with Audit Trail Mixture Analysis Relationship

More information

Quest Collaboration Services 3.6. Installation Guide

Quest Collaboration Services 3.6. Installation Guide Quest Collaboration Services 3.6 Installation Guide 2010 Quest Software, Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide

More information

User Bulletin. Applied Biosystems StepOne Real-Time PCR System DRAFT. SUBJECT: StepOne System Updates. In This Bulletin Installation Updates...

User Bulletin. Applied Biosystems StepOne Real-Time PCR System DRAFT. SUBJECT: StepOne System Updates. In This Bulletin Installation Updates... Applied Biosystems StepOne Real-Time PCR System User Bulletin User Bulletin Applied Biosystems StepOne Real-Time PCR System January 2007 SUBJECT: StepOne System Updates In This Bulletin Installation Updates.................................................

More information

HID Real-Time PCR Analysis Software

HID Real-Time PCR Analysis Software USER GUIDE HID Real-Time PCR Analysis Software Version 1.3 for use with: 7500 Real-Time PCR Instruments QuantStudio 5 Real-Time PCR Instruments (with 0.2-mL 96-Well Block) Quantifiler DNA Quantification

More information

1.0. Quest Enterprise Reporter Discovery Manager USER GUIDE

1.0. Quest Enterprise Reporter Discovery Manager USER GUIDE 1.0 Quest Enterprise Reporter Discovery Manager USER GUIDE 2012 Quest Software. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide

More information

Applied Biosystems SDS Plate Utility v2.2 For the ABI PRISM 7900HT Sequence Detection System

Applied Biosystems SDS Plate Utility v2.2 For the ABI PRISM 7900HT Sequence Detection System Applied Biosystems SDS Plate Utility v2.2 For the ABI PRISM 7900HT Sequence Detection System User Guide Copyright 2004 Applied Biosystems. All rights reserved. For Research Use Only. Not for use in diagnostic

More information

Applied Biosystems AutoCaller Software

Applied Biosystems AutoCaller Software User Guide Introduction Applied Biosystems AutoCaller Software SNP Genotyping Analysis Tool Preparation Tasks Manage Studies and Assay Information View and Edit Data Publish Data Copyright 2008, Applied

More information

Agilent Genomic Workbench 7.0

Agilent Genomic Workbench 7.0 Agilent Genomic Workbench 7.0 Workflow User Guide For Research Use Only. Not for use in diagnostic procedures. Agilent Technologies Notices Agilent Technologies, Inc. 2012, 2015 No part of this manual

More information

MicroSEQ ID Analysis Software Version 2.2. Getting Started Guide

MicroSEQ ID Analysis Software Version 2.2. Getting Started Guide MicroSEQ ID Analysis Software Version 2.2 Getting Started Guide For Research Use Only. Not intended for any animal or human therapeutic or diagnostic use. Information in this document is subject to change

More information

Procedure for DNA Database Analysis and Technical Review of Database Samples

Procedure for DNA Database Analysis and Technical Review of Database Samples Procedure for DNA Database Analysis and Technical Review of Database Samples 1.0 Purpose The purpose of this document is to provide a procedure for the analysis and technical review of quality control

More information

One Identity Active Roles 7.2

One Identity Active Roles 7.2 One Identity December 2017 This document provides information about the Active Roles Add_on Manager7.2. About Active Roles Add_on Manager New features Known issues System requirements Getting started with

More information

Ion Chef Instrument Network Connection

Ion Chef Instrument Network Connection Ion Chef Instrument Network Connection USER GUIDE Publication Number MAN0013444 Revision C.0 For Research Use Only. Not for use in diagnostic procedures. Manufacturer: Life Technologies Holdings Pte Ltd

More information

Agilent CytoGenomics 2.5

Agilent CytoGenomics 2.5 Agilent CytoGenomics 2.5 Installation and Administration Guide Research Use Only. Not for Diagnostic Procedures. Agilent Technologies Notices Agilent Technologies, Inc. 2012 No part of this manual may

More information

Applied Biosystems DNA Sequencing Analysis Software Version 5.1 for Windows XP and 2000 Platforms. User Guide

Applied Biosystems DNA Sequencing Analysis Software Version 5.1 for Windows XP and 2000 Platforms. User Guide Applied Biosystems DNA Sequencing Analysis Software Version 5.1 for Windows XP and 2000 Platforms User Guide Applied Biosystems DNA Sequencing Analysis Software Version 5.1 for Windows XP and 2000 Platforms

More information

Dell Statistica. Statistica Enterprise Server Installation Instructions

Dell Statistica. Statistica Enterprise Server Installation Instructions Dell Statistica Statistica Enterprise Server Installation Instructions 2014 Dell Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in

More information

Stellar Phoenix Windows Data Recovery - Pro

Stellar Phoenix Windows Data Recovery - Pro Stellar Phoenix Windows Data Recovery - Pro Version 4.2 Installation Manual 1 Overview Stellar Phoenix Windows Data Recovery is a complete solution to recover data from hard disk. However, Microsoft Windows

More information

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies Agilent 34826A BenchLink Data Logger for 34980A Getting Started Guide Agilent Technologies Notices Agilent Technologies, Inc. 2006 No part of this manual may be reproduced in any form or by any means (including

More information

JD Edwards EnterpriseOne 8.12 Standalone Client Installation Guide. for the Oracle Application Server

JD Edwards EnterpriseOne 8.12 Standalone Client Installation Guide. for the Oracle Application Server JD Edwards EnterpriseOne 8.12 Standalone Client Installation Guide for the Oracle Application Server April 2006 JD Edwards EnterpriseOne 8.12 Standalone Client Installation Guide Copyright 2006, Oracle.

More information

Applied Biosystems Variant Reporter Software

Applied Biosystems Variant Reporter Software Getting Started Guide Applied Biosystems Variant Reporter Software Version 1.1 Getting Started Guide Get Started Variant Reporter Software Version 1.1 Set Up the Software Set Up a Project Review a Project

More information

During the calibration the following keys move the autosampler in the desired directions: Page Up. Hold SHIFT key together with the above key

During the calibration the following keys move the autosampler in the desired directions: Page Up. Hold SHIFT key together with the above key To navigate within this document use the or keys ABI PRISM 310 Genetic Analyzer BEFORE PERFORMING ANY TROUBLESHOOTING WORK ON YOUR ABI PRISM 310 GENETIC ANALYZER, PLEASE READ THE INSTRUMENT USER S MANUAL

More information

Authentication Services ActiveRoles Integration Pack 2.1.x. Administration Guide

Authentication Services ActiveRoles Integration Pack 2.1.x. Administration Guide Authentication Services ActiveRoles Integration Pack 2.1.x Administration Guide Copyright 2017 One Identity LLC. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright.

More information

Stellar WAB to PST Converter 1.0

Stellar WAB to PST Converter 1.0 Stellar WAB to PST Converter 1.0 1 Overview Stellar WAB to PST Converter software converts Outlook Express Address Book, also known as Windows Address Book (WAB) files to Microsoft Outlook (PST) files.

More information

DME-N Network Driver Installation Guide for M7CL

DME-N Network Driver Installation Guide for M7CL DME-N Network Driver Installation Guide for M7CL ATTENTION SOFTWARE LICENSE AGREEMENT PLEASE READ THIS SOFTWARE LICENSE AGREEMENT ( AGREEMENT ) CAREFULLY BEFORE USING THIS SOFTWARE. YOU ARE ONLY PERMITTED

More information

Agilent Genomic Workbench 6.5

Agilent Genomic Workbench 6.5 Agilent Genomic Workbench 6.5 Product Overview Guide For Research Use Only. Not for use in diagnostic procedures. Agilent Technologies Notices Agilent Technologies, Inc. 2010, 2015 No part of this manual

More information

VERITAS StorageCentral 5.2

VERITAS StorageCentral 5.2 VERITAS StorageCentral 5.2 Release Notes Windows Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software Corporation makes no warranty of any kind

More information

PageScope Box Operator Ver. 3.2 User s Guide

PageScope Box Operator Ver. 3.2 User s Guide PageScope Box Operator Ver. 3.2 User s Guide Box Operator Contents 1 Introduction 1.1 System requirements...1-1 1.2 Restrictions...1-1 2 Installing Box Operator 2.1 Installation procedure...2-1 To install

More information

GeneMapper Software v3.5

GeneMapper Software v3.5 GeneMapper Software v3.5 User Guide August 29, 2003 9:32 am, GM v3.5 Title.fm Copyright 2003, Applied Biosystems. All rights reserved. For Research Use Only. Not for use in diagnostic procedures. Information

More information

Release Notes QuantStudio TM Design & Analysis Software v1.4.3

Release Notes QuantStudio TM Design & Analysis Software v1.4.3 Release Notes QuantStudio TM Design & Analysis Software v1.4.3 CONTENTS OVERVIEW OVERVIEW FEATURES UPDATES FIXED DEFECTS LICENSE COMPATIBILITY ONLINE HELP KNOWN ISSUES SYSTEM REQUIREMENTS INSTALL SOFTWARE

More information

Applied Biosystems MicroSeq ID Analysis Software Version 2.0

Applied Biosystems MicroSeq ID Analysis Software Version 2.0 Applied Biosystems MicroSeq ID Analysis Software Version 2.0 Getting Started Guide Getting Started Guide Applied Biosystems MicroSeq ID Analysis Software Version 2.0 Software Basics Administrator: Set

More information

Table of Contents. Part I About Oxygen Software. Part II Introduction. Part III Data extraction. Part IV Settings. Part V Copyright notes.

Table of Contents. Part I About Oxygen Software. Part II Introduction. Part III Data extraction. Part IV Settings. Part V Copyright notes. Contents I Table of Contents Part I About Oxygen Software 2 Part II Introduction 2 Part III Data extraction 3 1 Call Data Records... 3 File import... 4 Field Mapping... 6 Conditions... 8 Results... 11

More information

Security Removable Media Manager. Excel AddIn. Version (December 2015) Protect your valuable data

Security Removable Media Manager. Excel AddIn. Version (December 2015) Protect your valuable data Security Removable Media Manager Excel AddIn Version 7.0.8.0 (December 2015) Protect your valuable data 2011 Squadra Technologies, LLC. ALL RIGHTS RESERVED. This guide contains proprietary information

More information

SonicWALL CDP 2.1 Agent Tool User's Guide

SonicWALL CDP 2.1 Agent Tool User's Guide COMPREHENSIVE INTERNET SECURITY b SonicWALL CDP Series Appliances SonicWALL CDP 2.1 Agent Tool User's Guide SonicWALL CDP Agent Tool User s Guide Version 2.0 SonicWALL, Inc. 1143 Borregas Avenue Sunnyvale,

More information

GPS Explorer Software For Protein Identification Using the Applied Biosystems 4700 Proteomics Analyzer

GPS Explorer Software For Protein Identification Using the Applied Biosystems 4700 Proteomics Analyzer GPS Explorer Software For Protein Identification Using the Applied Biosystems 4700 Proteomics Analyzer Getting Started Guide GPS Explorer Software For Protein Identification Using the Applied Biosystems

More information

GeneMapper Software Version 3.5

GeneMapper Software Version 3.5 GeneMapper Software Version 3.5 User Guide Copyright 2003, Applied Biosystems. All rights reserved. For Research Use Only. Not for use in diagnostic procedures. Information in this document is subject

More information

Agilent ChemStation. ECM Interface Guide. Agilent Technologies

Agilent ChemStation. ECM Interface Guide. Agilent Technologies Agilent ChemStation ECM Interface Guide Agilent Technologies Notices Agilent Technologies, Inc. 2004, 2005-2007 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Variant Reporter Software

Variant Reporter Software Getting Started Guide Variant Reporter Software Getting Started Version 1.0 Set Up the Software Set Up a Project Review a Project Getting Started Guide Get Started Variant Reporter Software Version 1.0

More information

Symantec ediscovery Platform

Symantec ediscovery Platform Symantec ediscovery Platform Native Viewer (ActiveX) Installation Guide 7.1.5 Symantec ediscovery Platform : Native Viewer (ActiveX) Installation Guide The software described in this book is furnished

More information

Avaya VPN Client Software Release 10.05_100

Avaya VPN Client Software Release 10.05_100 Avaya VPN Client Software Release 10.05_100 1. Release Summary Release Date: September 1 st, 2011 Purpose: Software maintenance release to address customer requests and software issues. 2. Important Notes

More information

Analyzing a Project without a Reference

Analyzing a Project without a Reference Applied Biosystems Variant Reporter Software v1.0 Analyzing a Project without a Reference Quick Reference Card This quick reference card summarizes the procedures for setting up a project in Applied Biosystems

More information

Symantec Backup Exec System Recovery Granular Restore Option User's Guide

Symantec Backup Exec System Recovery Granular Restore Option User's Guide Symantec Backup Exec System Recovery Granular Restore Option User's Guide Symantec Backup Exec System Recovery Granular Restore Option User's Guide The software described in this book is furnished under

More information

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures.

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures. Agilent SureCall 3.5 Installation Guide For Research Use Only. Not for use in diagnostic procedures. Agilent Technologies Notices Agilent Technologies, Inc. 2016 No part of this manual may be reproduced

More information

NCD ThinPATH PC Installation Guide and Release Notes

NCD ThinPATH PC Installation Guide and Release Notes NCD ThinPATH PC Installation Guide and Release s Copyright Copyright 2001 by Network Computing Devices, Inc. (NCD).The information contained in this document is subject to change without notice. Network

More information

SonicWall Secure Mobile Access SMA 500v Virtual Appliance 8.6. Getting Started Guide

SonicWall Secure Mobile Access SMA 500v Virtual Appliance 8.6. Getting Started Guide SonicWall Secure Mobile Access SMA 500v Virtual Appliance 8.6 Getting Started Guide Copyright 2017 SonicWall Inc. All rights reserved. SonicWall is a trademark or registered trademark of SonicWall Inc.

More information

PRODUCT GUIDE. N u c l e u s D a t a R e c o v e r y. C o m P r i v a t e L i m i t e d

PRODUCT GUIDE. N u c l e u s D a t a R e c o v e r y. C o m P r i v a t e L i m i t e d PRODUCT GUIDE Table of Contents 1. About Kernel for PST Split... 4 1.1 Using this Manual... 4 1.2 Introduction to Kernel for PST Split... 4 1.3 Key Features... 5 1.4 System Requirements... 5 2. Understanding

More information

Tofino CMP Installation & Upgrade Guide Tofino CMP Version Tofino Firmware Version 1.7.0

Tofino CMP Installation & Upgrade Guide Tofino CMP Version Tofino Firmware Version 1.7.0 Tofino CMP Installation & Upgrade Guide Tofino CMP Version 1.7.0 Tofino Firmware Version 1.7.0 March 9, 2012 Copyright Information By res Security Inc and MT L Instrum ents While this information is presented

More information

Agilent Genomic Workbench Lite Edition 6.5

Agilent Genomic Workbench Lite Edition 6.5 Agilent Genomic Workbench Lite Edition 6.5 SureSelect Quality Analyzer User Guide For Research Use Only. Not for use in diagnostic procedures. Agilent Technologies Notices Agilent Technologies, Inc. 2010

More information

GeneChip TM Human Mapping

GeneChip TM Human Mapping GeneChip TM Human Mapping 250K Nsp Assay Software Module v1.1 User s Guide For Research Use Only. Not for use in diagnostic procedures. Information in this document is subject to change without notice.

More information

Microcat Daihatsu. Parts Quick Start Guide

Microcat Daihatsu. Parts Quick Start Guide Microcat Daihatsu Parts Quick Start Guide Contents Introduction... 2 About the guide... 2 Installing Microcat... 3 Getting started... 4 Microcat overview... 4 Set up Microcat... 7 Log on to Microcat...

More information

Microcat Authorisation Server (MAS ) User Guide

Microcat Authorisation Server (MAS ) User Guide Microcat Authorisation Server (MAS ) User Guide Contents Introduction... 2 Install Microcat Authorisation Server (MAS)... 3 Configure MAS... 4 License Options... 4 Internet Options... 5 Licence Manager...

More information

Microsoft Outlook Integration for ApplicationXtender 6.0

Microsoft Outlook Integration for ApplicationXtender 6.0 Microsoft Outlook Integration for ApplicationXtender 6.0 Integration Guide 300-008-270 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 1994-2009

More information

SonicWall Content Filtering Client for Windows and Mac OS

SonicWall Content Filtering Client for Windows and Mac OS SonicWall Content Filtering Client 3.1.60 for Windows and Mac OS January 2018 These release notes provide information about SonicWall Content Filtering Client 3.1.60 release for Windows and Mac OS. Topics:

More information

Migrating Performance Data to NetApp OnCommand Unified Manager 7.2

Migrating Performance Data to NetApp OnCommand Unified Manager 7.2 Technical Report Migrating Performance Data to NetApp OnCommand Unified Manager 7.2 Dhiman Chakraborty, Yuvaraju B, Tom Onacki, NetApp March 2018 TR-4589 Version 1.2 Abstract NetApp OnCommand Unified Manager

More information

Release Notes for Avaya Proactive Contact 5.0 Agent. Release Notes for Avaya Proactive Contact 5.0 Agent

Release Notes for Avaya Proactive Contact 5.0 Agent. Release Notes for Avaya Proactive Contact 5.0 Agent Release Notes for Avaya Proactive Contact 5.0 Agent Copyright@2011 Notice: While reasonable efforts were made to ensure that the information in this document was complete and accurate at the time of printing,

More information

Rapid Recovery License Portal Version User Guide

Rapid Recovery License Portal Version User Guide Rapid Recovery License Portal Version 6.1.0 User Guide 2017 Quest Software Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide

More information

FlukeView Forms. Documenting Software. Getting Started

FlukeView Forms. Documenting Software. Getting Started FlukeView Forms Documenting Software Getting Started PN 1574021 September 2000 2000 Fluke Corporation. All rights reserved. Printed in USA All product names are trademarks of their respective companies.

More information

SQL Optimizer for Oracle Installation Guide

SQL Optimizer for Oracle Installation Guide SQL Optimizer for Oracle 9.2.2 Installation Guide Copyright 2017 Quest Software Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this

More information

Security Removable Media Manager. Excel AddIn. Version (January 2018) Protect your valuable data

Security Removable Media Manager. Excel AddIn. Version (January 2018) Protect your valuable data Security Removable Media Manager Excel AddIn Version 9.9.0.0 (January 2018) Protect your valuable data 2011 Squadra Technologies, LLC. ALL RIGHTS RESERVED. This guide contains proprietary information protected

More information

VERITAS StorageCentral 5.2

VERITAS StorageCentral 5.2 VERITAS StorageCentral 5.2 Installation Instructions Windows Introduction to the Installation Process The steps below summarize what you must do to install StorageCentral on your system. Step To do this

More information

Agilent ChemStation Plus

Agilent ChemStation Plus Agilent ChemStation Plus Getting Started Guide Agilent Technologies Notices Agilent Technologies, Inc. 2004, 2006-2008 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Fujitsu ScandAll PRO V2.1.5 README

Fujitsu ScandAll PRO V2.1.5 README -------------------------------------------------------- Fujitsu ScandAll PRO V2.1.5 README -------------------------------------------------------- Copyright PFU Limited 2007-2017 This file contains information

More information

For Research Use Only. Not for use in diagnostic procedures.

For Research Use Only. Not for use in diagnostic procedures. SMRT View Guide For Research Use Only. Not for use in diagnostic procedures. P/N 100-088-600-02 Copyright 2012, Pacific Biosciences of California, Inc. All rights reserved. Information in this document

More information

Remote ialarm Center. User s Manual

Remote ialarm Center. User s Manual Remote ialarm Center User s Manual July 2011 COPYRIGHT 2011 AVer Information Inc. All rights reserved. No part of this document may be reproduced or transmitted in any form, or by any means without the

More information

SonicWall Global VPN Client Getting Started Guide

SonicWall Global VPN Client Getting Started Guide SonicWall Global VPN Client 4.10 Getting Started Guide Copyright 2017 SonicWall Inc. All rights reserved. SonicWall is a trademark or registered trademark of SonicWall Inc. and/or its affiliates in the

More information

Operating instructions for MixtureCalc v1.2 (Freeware Version)

Operating instructions for MixtureCalc v1.2 (Freeware Version) 1 Objective To provide instructions for importing data into and for performing mixture calculations using MixtureCalc-v1.2. MixtureCalc-v1.2 is validated for SPSA casework only and no warranty is provided

More information

New Features in Primavera Professional 15.2

New Features in Primavera Professional 15.2 New Features in Primavera Professional 15.2 COPYRIGHT & TRADEMARKS Copyright 2015, Oracle and/or its affiliates. All rights reserved. Oracle is a registered trademark of Oracle Corporation and/or its affiliates.

More information

Oracle Utilities Work and Asset Management

Oracle Utilities Work and Asset Management ESRI (ArcMap) Oracle Utilities Work and Asset Management ESRI (ArcMap) Installation and Configuration Guide Release 1.9.0.4.6 E26186-02 October 2012 Oracle Utilities Work and Asset Management ESRI (ArcMap)

More information

PRODUCT GUIDE. L e p i d e S o f t w a r e P r i v a t e L i m i t e d

PRODUCT GUIDE. L e p i d e S o f t w a r e P r i v a t e L i m i t e d PRODUCT GUIDE Table of Contents 1. About Kernel for PDF to Word... 4 1.1 Using this Manual... 4 1.2 Kernel for PDF to Word... 5 1.4 Who Should Use this Software?... 6 2. Getting Started... 7 2.1 Installation

More information

APDM. Accounts Payable InstaDocs

APDM. Accounts Payable InstaDocs DSD Business Systems Sage 100 Enhancements APDM Accounts Payable InstaDocs Version 6.00 2 A/P InstaDocs Information in this document is subject to change without notice. Copyright 1993-2018, DSD Business

More information

Dell GPOADmin 5.7. About Dell GPOADmin 5.7. New features. Release Notes. December 2013

Dell GPOADmin 5.7. About Dell GPOADmin 5.7. New features. Release Notes. December 2013 Dell GPOADmin 5.7 December 2013 These release notes provide information about the Dell GPOADmin release. About Dell GPOADmin 5.7 New features Resolved issues s System requirements Product licensing Getting

More information

Recording Server Maintenance Tool

Recording Server Maintenance Tool A-EE9-100-12 (1) Recording Server Maintenance Tool User s Guide Software Version 2.0.0 and Later NSR-500 NSR-1000 Series RealShot Manager Advanced 2012 Sony Corporation Table of Contents Copyright Notice...

More information

Nokia Horizon Manager Release Notes. Version1.4 SP1

Nokia Horizon Manager Release Notes. Version1.4 SP1 Nokia Horizon Manager Release Notes Version1.4 SP1 Part No. N450000005 Rev 001 November 2005 Nokia Contact Information Corporate Headquarters Web Site Telephone http://www.nokia.com 1-888-477-4566 or 1-650-625-2000

More information

ChromQuest 4.2 Chromatography Data System

ChromQuest 4.2 Chromatography Data System ChromQuest 4.2 Chromatography Data System Installation Guide CHROM-97200 Revision A April 2005 2006 Thermo Electron Corporation. All rights reserved. Surveyor is a registered trademark and ChromQuest is

More information

StoneGate IPsec VPN Client Release Notes for Version 5.0.0

StoneGate IPsec VPN Client Release Notes for Version 5.0.0 StoneGate IPsec VPN Client Release Notes for Version 5.0.0 Created: April 30, 2009 Table of Contents What s New... 3 System Requirements... 4 Build Version... 4 Product Binary Checksums... 4 Compatibility...

More information