NM1 Moulded Case Circuit Breaker. 1. General. 2. Type Designation. 3. Classification. Moulded Case Circuit Breakers. Russia.

Size: px
Start display at page:

Download "NM1 Moulded Case Circuit Breaker. 1. General. 2. Type Designation. 3. Classification. Moulded Case Circuit Breakers. Russia."

Transcription

1 Moulded Case Netherland Czech Ukrain ussia outh Africa NM Moulded Case Circuit Breaker. General. Certificates: KEMA, CC, PCT, EC, UKTET;. Electric ratings: AC V,/Z, ~A;. Mounting mode: Vertical and horizontal;. tandard: IEC/EN9.. Type Designation N M / Type of Npole for P breaker* Application: Blank: for power distribution; : for motor protection elease type and accessory code (please refer to table on page ) Number of poles Operation mode: Blank: direct operation with handle; P: motordriven operation; Z: Operation with rotary handle Code of Breaking capacity : standard type; higher type; current limiting type Frame size rated current Design sequence number MCCB code Company code Note *: There are types of Npole for P breaker A: without current release components, NPole is always at making status, not makes and breaks with other three poles; B: Without current release components, NPole makes with the other three poles(npole first makes then breaks); C: With current release components, NPole makes and breaks with other three poles(npole first makes then breaks); D: With current release components, NPole is always at making status, not makes and breaks with other three poles;. Classification According to breaking capacity of breaker: tandard type () igher type () Currentlimiting type ().9.

2 According to wiring mode: Front connection ear conection plugin According to operation mode: Direct operation with handle Operation with rotary handle Motordriven operation P P According to number of poles: P. Operation Conditions. Temperature: ~+0 ; the average value within h shall not exceed +.(please contact with us if temperature at the mounted site beyond above values); for the circuit breaker with thermomagnetic release, +0 is set to be the standard temperature for ratings. For temperature not between ~+0, please contact us for temperature compensation correction;. Altitude: not exceed 00m (Please contact with us for reduction coefficient if altitude at the mounted site beyond 00m). Pollution grade: Grade ;. Air conditions: At mounting site, relative humidity not exceed % at the max temperature of +0, higher relative humidity is allowable under lower temperature. For example, could be % at +, special measures should be taken to occurrence of dews...

3 Moulded Case. Technical Data 00,,,,,,, 0,,, 0,,,, 0,, 0, 0,,, /00/ 0/00// 0/00// 0/00// 0/00// Frame size current ated current (A) ated insulation voltage (V) ated impulse withstand voltage(v) Uimp ated operational voltage (V) Arcing distance (mm) Number of poles Breaking capacity code breaking capacity Icu (ka, M) Test sequence:otco ated service shortcircuit breaking capacity Ics (ka, M) Test sequence:otcotco 00 0/00// 0/00/ 0, 00, 0,, 0, 00 00, 0, 0/00/ AC 0V/00V/V AC V AC 0V/00V/V AC V.... Frame size rated current (A) ated ultimate shortcircuit Front connection ear connection Plug in type hunt release Undervoltage release Auxiliary contact Alarm contact Note: ① For products of ~00, zeroarcing breakers are available(except 00/P). ② The symbols OtCo, OtCotCo are used for defining the sequence of operations. O: breaking operation; t: the time interval between two successive shortcircuit operations; CO: a making operation followed, after the appropriate opening time, by a breaking operation

4 Moulded Case. elease. Product overview NM Moulded Case Circuit Breaker Inverse time breaking action property of the over current releasing of the breaker ( for power distribution) at the status that all poles are electrified simultaneously No. Test current I/In Conventional time Initial status Conventional nontrip current.0 h(in A), Ih(In A) Cold status Conventional trip current.0 h(in A), Ih(In A) ight after test no. Inverse timedelay breaking operation property of the over current tripping of the breaker(for motor protection) at the status that all poles are electrified simultaneously(conforms to IEC9) erial No. emark etting current Conventional time tartup status.0in h Cold status.in h ight after test number.in min Cold status In min Cold status In.In s t s Cold status In s t s Cold status In Npole of P circuit breaker is at the right side, see table below for rated current of C, D type Npole release. Frame size rated current (A) ated current (A) Note: The rated current of Npole can be made equal to the other phases... ated current at Npole (A) MCCB (fixed type) Plugin type ear connection Undervoltage release hunt release Alarm contact Auxiliary contact Motordriven operation mechanism 9 Extended manual operation handle Mechanical interlock Cage clamp terminal (efer to P) hort terminal cover Front connection plate 9....

5 Moulded Case. Curves(for power distribution, calibrated at 0 ). Curves Operation property curve of NM(0~) NM(0~) Operation property curve of NM(~) NM(~) time (s) time (s) Temperature compensation curve of NM(~) NM(~) Temperature compensation curve of NM(0~) NM(0~) ated ated current(%) Ambient temperature( ).. Multiple of rated current Multiple of rated current current(%) 0 0 Ambient temperature( ) 0

6 Operation property curve of NM Operation property curve of NM time (s) time (s) Multiple of rated current current(%) Temperature compensation curve of NM0 ated current(%) 0 0 Multiple of rated current Temperature compensation curve of NM ated 0 0 Ambient temperature( ) Ambient temperature( )..

7 Moulded Case Operation property curve of NM 00 Operation property curve of NM time (s) time (s) Multiple of rated current Multiple of rated current Temperature compensation curve of NM 00 ated Temperature compensation curve of NM ated current(%) current(%) Ambient temperature( ) 0 0 Ambient temperature( ). Temperature compensation correction NM series temperature compensation coefficient table calibration at 0, for the calibration at other temperature standards please contact with us Type Current range Compensation coefficient NM,, ~A NM,, 0~A NM,, ~A NM,, 0~A NM,, ~A NM0,, ~00A NM,, 0~A NM00, ~00A NM 0~A

8 9. Wiring Front connection(fixed connection) Extended connection terminals (for products ~A, extended terminals are available) Connection screws C Frame level Current (A) 0 0 Breaking capacity code Front connection screw exagonal socket screw (B) exagonal head screw (A) B A Cross screw (C).0.

9 Moulded Case Frame level Current (A) Breaking capacity code Front connection screw exagonal socket screw (B) exagonal head screw (A) Cross screw (C)

10 Frame level Current (A) Breaking capacity code Front connection screw exagonal socket screw (B) exagonal head screw (A) Cross screw (C) Cage clamp terminals (for products ~A, cage clamp terminals are available) A ty pe ear connection ear connection is applicable to P and P products of NM~NM00 B ty pe C ty pe Plugin connection Plugin connection is applicable to P and P products of NM~NM00..

11 Moulded Case LOAD LOAD LOAD OFF LINE ON ON ON LINE LOAD OFF OFF LOAD LINE LOAD Modes of downlead () and () illustrated in the figure are available for your wiring operation. For its breaking capacity may be affected, mode of downlead () is not recommended, before reception of any authorized announcement from the manufacturer; the mode of downlead () is prohibited for your wiring. LINE OFF LINE ON LOAD LINE () LOAD () LINE LINE () (). Overall and Mounting Dimensions Overall and mounting dimensions of NM (Fixed type) Barrier for arcing isolation A A A G B C L L E L F E F Undervoltage release G G G Φd Undervoltage release Barrier for arcing isolation Φd Φd W W P P (max) W P (mm) Model Overall dimensions Mounting dimensions.. C E F G G L L L W W W A B Φd NM NM NM NM NM NM.. NM NM...

12 Overall and mounting dimensions of NM0 00 (Fixed type) Barrier for arcing isolation Undervoltage release A E C L C F L B E F A L G G Undervoltage release Barrier for arcing isolation A W W P P (max) (mm) Model NM0 NM NM0 NM NM NM00/P NM00/ NM0 NM C 9.. C 9.. E F G 0. 0 G Overall 9. dimension Mounting dimensions..... L 0 0 L L W W A A B Φd..

13 Moulded Case Overall and mounting dimensions of NM (rear connection) M M P P Overall and mounting dimensions of NM0 00(rear connection) Φd Φd P P Boring diagram of rear connection P.. P

14 Plugin type 9 L M L L L Φd K Moungint plate P mounting diagram P boring diagram of mounting plate (mm) Model NM NM NM NM0 NM NM NM00 NM NM NM0 NM0 NM NM NM00 NM NM Dimensions of rear connection and plugin type A 0 Φd... Φd Φ. Φ. Φ. Φ. Φd. 9. ΦD ΦD L L L 9 9 L L 0/* 9/* /* /* /* /* M M M M K. J. 9 M M M M M M M M 0 Note: With "*" stands for dimension of p circuit breaker..

15 Moulded Case. Accessories Inner accessories Auxiliary contact Left Auxiliary alarm contact Alarm contact hunt release Undervoltage release ight andle Accessory code Accessory Magnetic only release Compound release NM NM P No accessory 0 00 Alarm contact 0 hunt release Auxiliary contact Undervoltage release hunt release, auxiliary contact hunt release, undervoltage release Two groups of auxiliary contacts Auxiliary contact, undervoltage release hunt release, alarm contact Auxiliary alarm contact Undervoltage release, alarm contact hunt release, auxiliary alarm contact Two groups auxiliary contact of auxiliary alarm contact Undervoltage release auxiliary alarm contact.. Mounting and wiring mode NM0 NM NM NM0 NM NM00 NM NM P P P P P P NM P

16 . Undervoltage release a. Un=~% Us, reliable operation b. Un=<% Us,prevent breaker from making c. Un=>% Us, reliable operation The rated voltage of the undervoltage release is z, 0V and 00V. Code of undervoltage release code A A D D voltage AC 0V AC 00V DC V DC 0V z z rated frequency Wiring diagram of undervoltage release. hunt release The rated control voltage of shunt release is z, 0V and 00V. Un=%~% Us, reliable operation Code of shunt release code A A A D D D voltage AC /V AC 0V AC 00V DC V DC 0V DC V z z/z z/z rated frequency Note: when voltage is DC V, rated current should be up to A±% Wiring diagram of shunt release. Auxiliary contact and alarm contact ated parameter of auxiliary contact Conventional heating current Ith (A) ated current Ie (A) at AC 00 V ated current Ie (A) at DC 0 V Inm A Inm 00A 0. Frame size a. Auxiliary contact Circuit breaker is at breaking status F F F F F Circuit breaker is at making status F..

17 Moulded Case b. Alarm contact When circuit breaker normally makes and breaks, alarm contact doesn't operate. After free release (or release due to failure) alarm contact operate; and after the circuit breaker operates again,alarm contact returns to the original status. B Circuit breaker is at "breaking" or "making" status B B B Circuit breaker is at free release (or alarming) status B B Wiring diagram of NM auxiliary contact Power supply Making circuit Breaking circuit Wiring diagram of NM alarm contact Power supply External accessories. Motordriven operation mechanism Model NM NM, NM NM0 NM, NM00, NM Electromagnet Motor Code of AC voltage A, A A, A Code of DC voltage D, D D, D Items tructure form Note: A V/0V/0V, A:0V/00V/V; D: DCV, D:DCV..9.

18 NM0,, 00, making and breaking diagram of motordriven operation mechanism(ac) K M Y K K K K M X K Y X Making T Making T Breaking M Breaking U~ With selflocking relay Without selflocking relay pecification AC z 0V or 00V otary manual operation mechanism Making/breaking wiring diagram of manual operation mechanism Mounting dimensions of manual operation mechanism Circuit breaker Y Φ Φ gemel X Φ. 0 Boring diagram of handle mounting D MIN=mm (mm) Model NM NM NM NM0 NM NM0 NM NM00 NM0 NM00 Mounting size 9 Y value of the handle related to the center of the breaker

19 Moulded Case Mounting and boring dimensions F C A B A φd D E A breaker B breaker L Note:. * stands for length of boring.. install the breaker on the frame first,then install the mechanical interlock on the breaker. (mm) Model A B NM 0 NM NM0 NM E F L Φd 0. * C D NM NM00.9.

20 . Complementary Technical Information. The customized products of NM, of which the capacity can be enriched to A is available.. NM products are equipped with connection plate when they are sold; if you need connection plate for products of other model, the connection plate should be ordered separately.. Only type breaker is applicable to manufacture NM series switch disconnector.. Terminal covers of the whole series NM products are available, and the protection degree can be up to IP0 after the breaker is equipped with terminal cover. For NM0~ For NM~. afe distance between other electric apparatuses for mounting (mm) Type NM00 NM NM NM NM NM0 NM Line side Load side ight side Left side Distance(min).9.

21 Moulded Case. Tightening torque table ated current (A) Tightening torque(n m) Front connection plate Boxing terminal Wire size(copper) AWG/MCM mm. In <In /0 9 <In <In 00 00<In 0 0<In 0 0 <In 00 00<In 0. Technical Data of NM series Frame current (A) Icu/Ics(kA) Model Number of poles Ui (V) 0V 0 V 0V 0 0V V NM NM NM NM NM NM NM NM NM NM NM NM NM NM0 NM0 NM0 NM0 NM NM NM NM NM00 NM00 NM 0V 0V 0V / / / / /. /. /. /. / /. /. /. /. / / /. / / / /. / /. / /. /. /. /. /. / / / /. /. / / / /. /. /. / / /. /. / / /0 / /. / / / / / / / /. / / / / /. 0/ 0/ / /. 0/ 0/ / /. /. /. /. / /. /. /. /. / /. /. /. /. /. /. /. / /. /. /. 0/ 0/ 0/ 0/ /. / / / / /. / / / / / / / /. / / /. / / / /.

22 Frame current (A) Icu/Icm(kA) Model Number of poles Ui (V) 0V 0 V 0V NM NM NM NM NM NM NM NM NM NM NM NM NM NM0 NM0 NM0 NM0 NM NM NM NM NM00 NM00 NM 0V 0V 0V /0 /. /. /. / / / / /. / / / / / / / / / / / / / / / /0 /. /. /. / / / / /. / / / / /. /. / / /. /. / / / / / / /0 /0 /0 /. /. /. / /0 /. /. /. / 0/ 0/ /. / 0/ 0/ /. / / / / 0 0V V Note: Parameters in black are only for your reference..9.

23 Moulded Case. Cascading.. Cascading (/0/0V) Upstream: NM~ Downstream: DZ, DZ, DZ, NB, NB, NM~ Upstream Breaking capacity (ka M) NM NM NM NM NM NM NM Downstream Breaking capacity (ka M) DZ 0 DZ 0 NB 0 NB(Icn=00A) NB(Icn=00A) 0 DZ 0 0 NM NM NM NM NM NM NM0 NM0 NM NM NM00 NM.9.

24 .9. NM NM NM0 NM0 NM0 NM NM NM NM00 NM

25 Moulded Case.. Cascading (0/00/V) Upstream: NM~ Downstream: DZ, DZ, DZ, NB, NB, NM~ Upstream Breaking capacity (ka M) NM NM NM NM NM NM NM Downstream Breaking capacity (ka M) DZ NB(Icn=00A) NB(Icn=00A) DZ NM NM NM NM NM NM NM0 NM0 NM NM NM00 NM.9.

26 .9. NM NM NM0 NM0 NM0 NM NM NM NM00 NM00

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

Air Circuit Breaker (ACB)

Air Circuit Breaker (ACB) MPACT Air Circuit Breaker (ACB) Rated from 0 to 000A the MPACT circuit breaker has been designed to meet the most stringent demands in fault detection and safe interruption thereof. Available in frame

More information

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu) DC circuit supplementary protectors for photovoltaic C60PV-DC PB108403-50 The C60PV-DC is a DC circuit breaker dedicated to multi string photovoltaic. This circuit breaker is designed to protect the cables

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

NC2 Contactor, 115~630A. 1. General. 2. Type Designation. 3. Terminal Connection. Cabling(Cu) Cable 2. Tightening torque (N m) Screw size

NC2 Contactor, 115~630A. 1. General. 2. Type Designation. 3. Terminal Connection. Cabling(Cu) Cable 2. Tightening torque (N m) Screw size R C US LISTED EU Germany Czech Ukrain South Africa USA NC Contactor, 5~30A. General. Certificates: CE, VDE, ESC, UKRTEST, RCC, UL.. Electric ratings; AC50/0Hz, up to 000V, up to 30A;.3 Application: remote

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Motor protection relays

Motor protection relays Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30

More information

RM4TR31 three-phase network control relay RM4-T - range V

RM4TR31 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 160..220 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit

More information

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Motor protection circuit breakers

Motor protection circuit breakers Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability

More information

Supplementary Circuit Protectors Type GSB63

Supplementary Circuit Protectors Type GSB63 Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

K1B004TLH cam switch - 1 pole A - screw mounting

K1B004TLH cam switch - 1 pole A - screw mounting Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide

More information

K1D012ULH cam changeover switch - 2-pole A - screw mounting

K1D012ULH cam changeover switch - 2-pole A - screw mounting Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

RM4TA32 three-phase network control relay RM4-T - range V

RM4TA32 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 380..500 V Complementary [Us] rated supply voltage Output contacts Main Range of product Product or component type Relay type Product specific

More information

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers Type CTI 25M, CTI 45MB Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is

More information

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1 Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload

More information

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

K1D004ACH cam switch - 4-pole A - for Ø 22 mm Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

K1F006ALH cam switch - 6-pole A - screw mounting

K1F006ALH cam switch - 6-pole A - screw mounting Characteristics cam switch - 6-pole - 45-12 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting

More information

RM4JA01F current measurement relay RM4-J - range ma V AC

RM4JA01F current measurement relay RM4-J - range ma V AC Characteristics current measurement relay RM4-J - range 3..1000 ma - 110..130 V AC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Power consumption in

More information

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 MKING MODERN LIVING POSSIBLE Technical brochure CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit- and overload protection of motor applications

More information

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC Characteristics adjustable off-delay timing relay - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay

More information

Motor protection circuit breakers

Motor protection circuit breakers R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,

More information

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct

More information

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB Motors Automation Energy Transmission & Distribution Coatings DWB Molded Case Circuit Breakers DWB Molded Case Circuit Breakers Molded Case Circuit Breakers DWB Summary Presentation 0 General Characteristics

More information

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

RUC-M industrial relays for DC loads

RUC-M industrial relays for DC loads Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Min. breaking capacity

More information

SR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display

SR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display Characteristics compact smart relay Zelio Logic - 20 I O - 100..240 V AC - clock - display Main Range of product Product or component type Complementary Local display Number or control scheme lines Cycle

More information

RM4JA32MW current measurement relay RM4-J - range A V AC DC

RM4JA32MW current measurement relay RM4-J - range A V AC DC Characteristics current measurement relay RM4-J - range 0.3..15 A - 24..240 V AC DC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Power consumption in

More information

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display Characteristics modular smart relay Zelio Logic - 26 I O - 100..240 V AC - clock - display Main Range of product Product or component type Zelio Logic Modular smart relay Complementary Local display Number

More information

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display Characteristics modular smart relay Zelio Logic - 26 I O - 100..240 V AC - clock - display Main Range of product Product or component type Zelio Logic Modular smart relay Complementary Local display Number

More information

RM4UA33M voltage measurement relay RM4-U - range V V AC

RM4UA33M voltage measurement relay RM4-U - range V V AC Characteristics voltage measurement relay RM4-U - range 30..500 V - 220..240 V AC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Time delay Power consumption

More information

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display Characteristics compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display Main Commercial Status Range of product Product or component type Commercialised Zelio Logic Compact smart relay Complementary

More information

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal

More information

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)

More information

RATINGS AND SPECIFICATIONS

RATINGS AND SPECIFICATIONS RATINGS AND SPECIFICATIONS MCCB ELECTRICAL CHARACTERISTICS TO IEC 609472, EN 609472, JIS C 121 ANN.1, AS/NZS 39472, NEMA AB1 Frame Quantity Unit Condition 125 Model E125 S125 Number of Poles 1 Type NJ

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors

More information

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3 Wiring diagrams Content Information for reading and graphic symbols... 5/2 Wiring diagrams of the circuit-breakers... 5/3 Electrical accessories... 5/4 5/1 Information for reading and graphic symbols State

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60 DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm Characteristics body for BCD encoded output switch - 1 pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Sub-assembly

More information

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC Characteristics time delay relay for star-delta starter - 0.05..1 s - 24 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time

More information

Description. Installation. Power supply

Description. Installation. Power supply Air circuit breakers Special versions Series MEGT07 0V/500V/DC 50 up to 5000 A The air circuit breakers MEGT07 are suitable for use as disconnecting switch in DC distributions up to a rated voltage of

More information

MOTOR & CIRCUIT PROTECTION

MOTOR & CIRCUIT PROTECTION 2 MOTOR & CIRCUIT PROTECTION Motor Protection Circuit Breakers p2-1 Motor Protection Relays p2-13 Thermistor Protection Relay p2-18 Fuse Holders p2-20 Miniature Circuit Breakers p2-23 Residual Current

More information

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm Product data sheet Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal

More information

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure MKING MODERN LIVING POSSIBLE CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M - 100 Technical brochure 2 IC.PD.C00.5.02-520B3595 Danfoss /S (R-MC/mr) 08-2009 Contents Page Circuit Breakers/

More information

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display Characteristics compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display Main Range of product Product or component type Zelio Logic Compact smart relay Complementary Local display Number or

More information

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20 Characteristics limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20 Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device

More information

TeSys contactors From 115 to 2750 A

TeSys contactors From 115 to 2750 A Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW) Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED Characteristics power plug-in relay - Zelio RPM - 4 C/O - 230 V AC - 15 A - with LED Complementary Shape of pin [Ui] rated insulation voltage Main Range of product Series name Product or component type

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW) Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20 Characteristics limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20 Complementary Switch actuation Electrical connection Contacts insulation form Number of steps 1 Positive opening

More information

RM4JA31M current measurement relay RM4-J - range ma V AC

RM4JA31M current measurement relay RM4-J - range ma V AC Characteristics current measurement relay RM4-J - range 3..1000 ma - 220..240 V AC Complementary [Us] rated supply voltage Operating voltage tolerance Main Range of product Product or component type Relay

More information

RPM13F7 power plug-in relay - Zelio RPM - 1 C/O V AC - 15 A - with LED

RPM13F7 power plug-in relay - Zelio RPM - 1 C/O V AC - 15 A - with LED Characteristics power plug-in relay - Zelio RPM - 1 C/O - 120 V AC - 15 A - with LED Stock Code: Non-Stock - Not normally stocked in distribution facility Price*: 5.00 USD Complementary Shape of pin [Ui]

More information

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations

More information

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm Characteristics body for BCD encoded output switch - 1 pole - 30-12 A - for Ø 22 mm Complementary Main Number of decimal 11 Switching angle 30 Range of product Product or component type Component name

More information

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT Characteristics limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT Complementary Switch actuation Electrical connection Contacts insulation form Number of steps 1 Positive

More information

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13 Characteristics limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13 Complementary Switch actuation Electrical connection Contacts insulation form Number of steps 1 Positive opening

More information

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm Characteristics sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm Main Range of product Product or component type [Us] rated supply voltage Number of channels 16 Number of terminal

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

XCKP2145N12 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

XCKP2145N12 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT Characteristics limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device

More information

XCKD2145N12 limit switch XCKD - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

XCKD2145N12 limit switch XCKD - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT Characteristics limit switch XCKD - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT Complementary Switch actuation Electrical connection Cable entry Contacts insulation form Positive opening

More information

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz Product datasheet Characteristics RE7YA12BU Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range Zelio Time Industrial timing relay

More information

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics. Characteristics soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application

More information

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display Characteristics compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display Main Range of product Product or component type Complementary Local display Number or control scheme lines Cycle

More information

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D75S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5

More information

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated

More information

Square D General Purpose Relays

Square D General Purpose Relays Square D General Purpose Relays Class 850R miniature control relays 850RS4 standard 850RS24 low level 850RS34 hermetically sealed Catalog 204 Contents Class 850R miniature control relays bbspecifications....................................................

More information

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation ARC FAULT DETECTION DEVICE (AFDD) The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation The S-ARC1 is the new Arc Fault Detection Device (AFDD) with an integrated Miniature Circuit

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11 Characteristics limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11 Complementary Switch actuation Electrical connection Cable entry Contacts insulation form Positive opening

More information

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un): Safety module CS AR-91, according to EN 81 Safety modules for the lift automatic floor levelling operation according to EN 81 Main functions For safety applications up to SIL 3 / PL e Choice between automatic

More information

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A Complementary Shape of pin Main Range of product Series name Product or component type Device short name Contacts type and composition

More information

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx Characteristics limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx Main Range of product Series name Product or component type Device short name Sensor design Body type Head type Material Fixing

More information

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions with adaptor (V) with adaptor (H) Power relays of general application AC and DC coils Mounting: in sockets; 35 mm rail mount acc. to PN-EN 60715; on panel; PCB Versions: faston 187 (4,8 x 0,5 mm); faston

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery

More information

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC Characteristics off-delay timing relay with control contact - 0.05..1 s - 24 V AC DC - 1OC Main Range of product Product or component type Component name Time delay type Time delay range [Us] rated supply

More information

QF(26) - Series Miniature Circuit Breakers - High Rating ( A)

QF(26) - Series Miniature Circuit Breakers - High Rating ( A) 1 pole 2 pole 3 pole 3+N Features AC Circuit Breaker Hydraulic-Magnetic technology % rating capability, independent of ambient temperature One, two, three pole, 1+N and 3+N (VDE) VC 8036 compliant (SANS

More information

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation. Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010 NG160 circuit breaker Ready to install NG160 General contents Presentation

More information

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O Characteristics industrial timing relay - 0.3..30 s - type A - 24 V AC/DC, 110..240 V AC - 1 C/O Main Range of product Product or component type Component name Time delay type Time delay range [Us] rated

More information

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D47S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW) Characteristics soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW)/500V(45kW) Price* : 683.00 GBP Main Range of product Altistart 22 Product or component type Product destination Product

More information

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Max. breaking capacity

More information