1 Microsoft HT0-102 Questions $ Answers Number: HT0-102 Passing Score: 800 Time Limit: 120 min File Version: Microsoft HT0-102 Questions $ Answers Exam Name: HTI+ Systems Infrastructure

2 Certdumps QUESTION 1 Which of the following serial protocols allows the daisy chaining of devices? A. Fire Wire B. RS-232 C. RS-422 D. RS-485 /Reference: QUESTION 2 Which of the following is a requirement of a home automation system that allows the system to be set up for out of band remote maintenance from an off-site location? A. Dial-in modem B. Local terminal C. Infrared remote D. Wireless access point /Reference: QUESTION 3 Which of the following is a support that is mounted to the backboard and used to manage cables? A. Conduit B. 66 block C. D-ring D. Cable tray /Reference: QUESTION 4 A technician is programming the locations for devices used in home automation. Which of the following describes the Layer 2 address of the OSI model? A. IP address B. MAC address C. X10 address

3 D address /Reference: QUESTION 5 The design of a system requires a wall-mounted control device that works with a RS-485 based control processor. Control needs to be available at 16 locations. The interface should allow the technician to customize the menu options with icons and text associated with each of the push buttons. Which of the following meets the design criteria? A. Web pad B. LCD keypad C. If remove control D. Touch screen controller /Reference: QUESTION 6 An integrated home automation system is being designed to use a personal computer equipped with a single IEEE 1394 port. What is the total number of devices that additional ports are needed? A. 23 B. 43 C. 63 D. 83 /Reference: QUESTION 7 Which of the following methods offer protection from attenuation in larger installations using an X10 protocol to control devices? A. IR repeater

4 B. Signal bridge C. RS-232 to RS-485 converter D. 75 ohm to 100 ohm converter /Reference: QUESTION 8 Which of the following standards has the greatest maximum distance from the central office of the telephone company to the home? A. ADSL B. SDSL C. IDSL D. G.SHDSL /Reference: QUESTION 9 Which of the following systems utilizes the electrical cabling as a control media throughout the house? A. PLC B. HomeRF C. HomePNA D. Broadband coaxial /Reference: QUESTION 10 In a wireless security system, the controller should monitor each transmitter for: A. high interference B. low radiation level C. high humidity D. low battery /Reference:

5 QUESTION 11 Which of the following terms describes a point or group of points in an alarm system? A. Zone B. Area C. Perimeter D. Demarcation /Reference: QUESTION 12 Which of the following tools is used to fasten a connector to a cable end? A. Crimper B. Wire strippers C. Lineman's pliers D. Punch-down tool /Reference: QUESTION 13 Which of the following ANSI/TIA/EIA standards most directly concerns residential low-voltage an telecommunication cabling? A. 568-B B. 570 C. 570-A D. 606 /Reference: QUESTION 14 A programmable HVAC thermostat can be accessed remotely to: A. warm of a high heating bill B. light up the thermostat in dark hallways C. power the HVAC upon the loss of AC power D. allow the panel to control the temperature settings of the thermostat

6 /Reference: QUESTION 15 Which of the following types of systems is created by combining many signals into an existing single cable? A. Diplex B. Duplex C. Multiplex D. Balanced /Reference: QUESTION 16 A design calls for the installation of devices using the current AC wiring for control. The installation is complete, and the technician discovers that only one-half of the devices can be accessed from the central processor. Which of the following steps will resolve this problem? A. Rewire the home. B. Install a phase coupler. C. Place all devices on the same circuit. D. Move all devices closer to the central processor. /Reference: QUESTION 17 Which of the following information is NOT required when a technician is programming a control system? A. A cold water pipe B. A secondary ground rod C. The nearest grounded AC outlet D. The electrical service entrance ground /Reference: QUESTION 18

7 If the technician has verified that all the phone jacks but one in a home have a dial tone, the next step the technician should take is to check. A. The termination. B. For cross talk. C. For split pairs. D. The polarity. /Reference: QUESTION 19 Which of the following topologies is associated with the home run method? A. Bus. B. Star. C. Ring. D. Mesh. /Reference: QUESTION 20 Which of the following connectors is the eight pin connector used for data transmission over twisted pair wires? Pin connector used for data transmission over standard telephone wires. A. DIN. B. BNC C. RJ-45. D. RJ-11. /Reference: QUESTION 21 Which of the following connectors is used in the Community Access Television (CATV) industry on coaxial cable? A. BNC. B. RG-62 C. N D. F

8 /Reference: QUESTION 22 In order for devices to communicate and integrate over the home LAN infrastructure, the home integrate should ideally connect into these sub systems at the associated sub system. A. End devices. B. Control panel. C. Distribution panel. D. Residential gateway. /Reference: QUESTION 23 The maximum distance a control processor can be placed from the control device that supports RS at a data rate of 100 kbps is. A. 200 ft. B. 200 ft. C. 2,000 ft. D. 4,000 ft. /Reference: QUESTION 24 Which of the following tools will identify the location of a break in a cable? A. Multimeter B. Packet analyzer C. Frequency generator D. Time Domain Reflectometer (TDR) /Reference: QUESTION 25 Which of the following is NOT a valid X10 device address?

9 A. S12 B. L9 C. G15 D. A2 /Reference: QUESTION 26 A transformer is an electrical device that converts. A. AC voltage to a different AC voltage. B. AC wattage to a different AC wattage. C. DC voltage to a different DC voltage. D. DC wattage to a different tdc wattage. /Reference: QUESTION 27 Service wires brought to a building underground are referred to as a service. A. bus B. line C. mast D. lateral /Reference: QUESTION 28 Which of the following connector types would NOT be found on a structured wiring system? A. F B. RCA C. DB-15 D. RJ-45

10 /Reference: QUESTION 29 Cabling for all current and future client needs should be in place by the end of which of the following installation phases? A. Finish B. Trim-out C. Rough-in D. Programming /Reference: QUESTION 30 Which of the following best describes the demarcation point (demarc)? A. Main distribution facility B. Intermediate distribution facility C. Point in the wall the installer will measure from to determine a jack placement D. Point where the telephone company's responsibility ends and the owner's responsibility begins /Reference: QUESTION 31 The National Electrical Code (NEC) specifies the minimum size coppepr conductor for 120-volts AC residential service as: A. 14 American Wire Gauge (AWG) B. 12 American Wire Gauge (AWG) C. 10 American Wire Gauge (AWG) D. 8 American Wire Gauge (AWG) /Reference: QUESTION 32 Volt-amperes (VA) for a single-phase AC electrical circuit can be calculated as: A. volts times amperes B. watts divided by volts

11 C. volts times power factor D. amperes times resistance /Reference: QUESTION 33 The National Electrical Code (NEC) protects against electric shock in a Class 2 low-voltage circuit by: A. requiring surge protection B. specifying aluminum wire C. limiting current to 5 ma or less D. specifying redundant circuits /Reference: QUESTION 34 Communications cabling and other audio/video cabling should always cross electrical wiring at an angle of. A. 25 degrees B. 45 degrees C. 90 degrees D. 120 degrees /Reference: QUESTION 35 Which of the following types of cables has the MOST resistance to interference? A. Coaxial B. Fiber-optic C. Shielded Twisted Pair (STP) D. Unshielded Twisted Pair (UTP) /Reference:

12 QUESTION 36 The purpose of the National Electrical Code (NEC) is to provide minimum standards for the. A. performance standards of networks B. performance measures of wiring systems C. procedures for the testing of wiring systems D. practical safeguarding of persons and property /Reference: QUESTION 37 The purpose of the National Electrical Code (NEC) is to do which of the following? A. Train persons in the installation of high-voltage electrical products. B. Train persons in the installation of both high and low-voltage electrical products. C. Safeguard persons and property from hazards arising from the use of electricity. D. Assist designers by providing a reference for the creation of electrical job specifications. /Reference: QUESTION 38 A technician is on-site install a cable modem and router for a residential home network. There is a preexisting home network that consists of five computes all connected by 10Base2 Thinnet. The technician needs to install a router, hub, and firewall. Which of the following items should the technician use to accomplish this task? A. Five 10/100Base-T NIC cards and UTP cable with RJ-45 connectors B. Five 10/100Base-T NIC cards and STP cable with RJ-11 connectors C. Five 10Base5 NIC cards and UTP cable with AUI connectors D. Five 10Base2 NIC cards and UTP cable with RJ-45 connectors Correct Answer: /Reference: Answer: AThe router, hub, and firewall will most likely support UTP only. The easy solution is to change Network cards on the five PCs. QUESTION 39 The most common source of an electrical voltage surge is A. A. power failure B. blown transformer C. downed power pole D. nearby lighting strike

13 /Reference: QUESTION 40 Which of the following will provide continuous access to the home automation system using the Internet for communications? A. Dial-in server. B. Dial-up server. C. Dedicated line D. Switched line /Reference: QUESTION 41 The IEEE wireless protocol standard operates in: A. low frequency B. high frequency C. microwave frequency D. very high frequency /Reference: QUESTION 42 Which of the following should be used to provide greater flexibility for future changes in a home automation network? A. Daisy chain B. Patch panel C. Coaxial cable D. Fiber-optic cable /Reference: QUESTION 43

14 Which of the following ANSI/TIA/EIA standards most directly concerns residential low-voltage and telecommunication cabling? A. A 568-B B. 570 C. 570-A D. 606 /Reference: QUESTION 44 An automatic water shut off valve detection device must be located. A. at the water main B. at all plumbing fixtures C. on both hot and cold water pipes D. at the lowest possible point of water drain /Reference: QUESTION 45 Which of the following ANSI/TIA/EIA standards most directly concerns residential low-voltage an telecommunication cabling? A. 568-B B. 570 C. 570-A D. 606 /Reference: QUESTION 46 Which of the following is the recommended best practice for integrating the signal distribution and device controllers in a hoe automation project? A. Applying the ANSI 570A standard B. Installing a centralized home Control center C. Using Category 3 for voice and Category 6 for data D. Using blue cable for data and yellow cable for video

15 /Reference: QUESTION 47 Which of the following DSL standards has the greatest maximum downstream speed. A. ADSL B. IDSL C. VDSL D. HDSL-2 /Reference: QUESTION 48 Which of the following types of Digital Subscriber Lines (DSL) uses filters on each phone instead of a single splitter at the point the line pair enters the building? A. HDSL B. G.lite C. DSLAM D. Bridged ADSL /Reference: QUESTION 49 The component in a fiber cable designed to trap the light signal inside the optical fiber is called the. A. core B. cladding C. cable jacket D. protective buffer /Reference: QUESTION 50 Which of the following devices is used to arm and disarm the alarm system?

16 A. Keypad B. Terminal C. Knife switch D. Mercury switch /Reference: QUESTION 51 What is the maximum number of feet that Asymmetric Digital Subscriber Line (ADSL) can run on a 26 AWG cable? A. 6,000-9,000 B. 10,000-13,000 C. 15,000-18,000 D. 19,000-21,000 /Reference: QUESTION 52 Which of the following specifies the building requirements for grounding? A. National Electrical Code B. Electrical Industry Association (EIA) C. National Fire Protection Association (NFPA) D. American National Standards Institute (ANSI) /Reference: QUESTION 53 The proper cable to be used in connecting a Direct Broadcast Satellite (DBS) dish to a receives is A. A. A Romex cable B. Category 5 STP C. swept-tested RG-6 D. 16 AWG speaker wire

17 /Reference: QUESTION 54 Which of the following technologies should a design specify if a customer desires to control all elements of the whole house control system with a single remote from any location? A. Optical switches B. Mechanical switches C. Infrared light transceivers D. Radio Frequency (RF) transceivers /Reference: QUESTION 55 Which of the following cable types is used to climinate the effects of Electromagnetic Interference (EMI)? A. Category 5e UTP. B. Category 5 STP. C. Fiber Optic cable. D. Coaxial cable. /Reference: QUESTION 56 To limit the voltage imposed by lightning and line surges, electrical systems such as reformers and generators should be connected to which of the following. A. Earth ground. B. Circuit breaker. C. Electrical supply. D. Surge Suppressor. /Reference:

18 QUESTION 57 Which of the following connectors is used with Category 5 cables. A. RJ-31. B. RJ-45. C. RJ-48 D. RJ-61 /Reference: QUESTION 58 Which of the following types of cables is considered unbalanced? A. Coaxial. B. Fiber optic. C. Shielded Twisted Pair (STP) D. Unshielded Twisted Pair (UTP) /Reference: QUESTION 59 According to the Telecommunications Industry Association (TIA), which of the following topologies is the preferred method of wiring for residential premises? A. Bus B. Star C. Ring D. Mesh /Reference: QUESTION 60 Which of the following is the maximum number of addresses that can be assigned to a single X10 system? A. 64 B. 128 C. 256 D. 512

19 /Reference: QUESTION 61 Which of the following types of cables I prone to interference? A. Coaxial. B. Fiber optic. C. Shielded Twisted Pair (STP). D. Unshielded Twisted Pair (UTP) /Reference: QUESTION 62 The minimum bend radius standard for a Category 5 cable installation is: A. 4 in. B. 8 in. C. 12 in. D. 24 in. /Reference: QUESTION 63 According to the National Electrical Code (NEC), which of the following colors is acceptable for the "hot" wire in a residence? A. Red B. Grey C. White D. Green /Reference: QUESTION 64 Which of the following would NOT be found in the distribution panel of structured pre-wire?

20 A. LAN hub B. Structured outlet C. Video distribution module D. Telecommunications module /Reference: QUESTION 65 Which of the following types of cables may NOT be used to maintain a Category 5 certification for data transfer speed? A. UTP Category 3 B. STP Category 5 C. UTP Category 5e D. STP Category 6 /Reference: QUESTION 66 The purpose of an Uninterruptible Power Supply (UPS) is to: A. correct power factor B. correct phase imbalances C. solve grounding problems D. provide continuous, transient-free sinusoidal power /Reference: QUESTION 67 Quad-shield coaxial cable has: A. two foil shields covered by two braids B. three foil shields covered by a braid C. a foil shield covered by a braid, covered by a foil shield, covered by an outside braid D. a braid covered by a foil shield, covered by a braid, covered by an outside foil shield

21 /Reference: QUESTION 68 Which of the following is a type of wireless computer keyboard connector? A. DIN B. IrDA C. COM D. USB /Reference: QUESTION 69 Which of the following EIA/TIA standards defines the requirements for low-voltage cabling systems in single and multi-tenant residencies? A. 607A B. 570A C. 569A D. 568B /Reference: QUESTION 70 The area above a room or building space in which the primary function is air handling is know as the. A. riser area B. work area C. plenum area D. conduit area /Reference: QUESTION 71 Which of the following must be installed to allow infrared remote programming of a Central Control Unit (CCU) from anywhere in the home? A. Hub

22 B. Amplifier C. Repeater D. Optical switch /Reference: QUESTION 72 Which of the following tools is used to fasten an RJ-45 plug to a cable end? A. Crimper B. Wire strippers C. Lineman's pliers D. Punch-down tool /Reference: QUESTION 73 Which of the following termination devices could maintain Category 5 certification for data transfer speed? A. Wire nut B. Barrier strip C. Phoenix connector D. Type 110 punch-down block /Reference: QUESTION 74 If a home is automated with the available wireless standards, which of he following describes the available 11 Mbps protocol? A a B b C c D g /Reference:

23 QUESTION 75 The installation of an X10-based system in an apartment unit is complete. The apartment complex uses shared services to supply each unit with electric power, natural gas, and water. To protect the equipment, all A/V components and computers are connected to the A/C wiring by using surge suppressors. The client calls and states that some of the devices are operating erratically and spontaneously from any of the X10 controllers. The equipment is operating manually and other devices are operating normally. To remedy this problem, the technician should. A. install new wiring B. install a phase coupler C. replace the surge suppressors D. install a multiphase blocking coupler /Reference: QUESTION 76 Which of the following best describes the minimum Federal Communications Commission (FCC) requirements for home copper wiring? A. Solid, 24 gauge, twisted, marked to comply with Category 3 B. Solid, 18 gauge, twisted, marked to comply with Category 6 C. Standard, 24 gauge, twisted, marked to comply with Category D. Standard, 18 gauge, flat or twisted, marked to comply with Category 3 /Reference: QUESTION 77 Which of the following DSL types does NOT use POTS on the same line? A. ADSL B. G.lite C. VDSL /Reference: QUESTION 78 Which of the following is considered the "brain" of the home integration system? A. Control panel

24 B. Access point C. Distribution panel D. Demarcation point /Reference: QUESTION 79 A home is fully integrated and controlled by one processor. The instant messaging and notification are not working. Which of the following should the technician check first? A. X10 network B. Video distribution C. Computer network D. Internet connection /Reference: QUESTION 80 If the home automation controller supports connections to remote devices via RS-232 ports, and the design specifies 8 remote devices, how many RS-232 ports need to be installed in the controller? A. 1 B. 2 C. 4 D. 8 /Reference: QUESTION 81 According to the EIA/TIA 570 standard, which of the following types of cable make up a grade one outlet? A. One UTP Category 3 and one 75 ohm coaxial cable. B. Two UTP Category 5 and one UTP Category 3 cable. C. Two UTP Category 5 one UTP Category 3 and one 75 ohm coaxial cable. D. One UTP Category 5 one 75 ohm coaxial cable and one fiber optic cable.

25 /Reference: QUESTION 82 A technician is terminating a coaxial cable with a BNC connector. The maximum length of outer jacket that should be removed is. A. 3/16 in. B. 4/16 in. C. 8/16 in. D. 11/16 in. /Reference: QUESTION 83 Which of the following cables is used in Community Access Televisions (CATV). A. RG-58 B. RG-62 C. RG-6U D. RG-8 /Reference: QUESTION 84 Which of the following pairs of not for profit organizations develop and adopt standards for home automation technology? A. Continental Automated Building Association (CABA) and Internet Home Alliance (IHA). B. Customs Electronic Design and Installation Association (CEDIA) and Internet Home Alliance (IHA). C. Consumer Electronics Association (CEA) and Continetal Automated Building Association (CABA). D. Consumer Electronics Association (CEA) and Custom Electronic Design and Installation Association (CEDIA). /Reference: QUESTION 85 Which of the following should be used to provide greater flexibility for future changes in a home automation network? A. Home run.

26 B. Patch Panel. C. Fiber optic cable. /Reference: QUESTION 86 Which of the following video cables would provide optimal performance with satellite residential or light commercial use? A. RG-59 B. RG-6 C. Category 5 D. Category 6 /Reference: QUESTION 87 Which of the following types of cables has the most resistance to interference? A. Coaxial. B. Fiber optic. C. Shielded Twisted Pair (STP) D. Unshielded Twisted Pair (UTP) /Reference: QUESTION 88 The term "hertz" refers to the number of. A. cycle per second B. cycles per millisecond C. times voltage returns to 0 D. times current returns to 0 /Reference:

27 QUESTION 89 When wires are connected to a standard 120-volt outlet receptacle, the black wire is connected to which of the following terminals? A. Red B. Green C. Silver D. Copper /Reference: QUESTION 90 Which of the following could NOT be used as a control device in a home automation system? A. Touchscreen B. Motion detector C. Structured outlet D. Handheld remote /Reference: QUESTION 91 Which of the following is the proper fire rating for wire running in ventilation air spaces? A. PVC B. Riser C. Plenum D. Shielded /Reference: QUESTION 92 The unit of measurement for electrical power is the. A. volt B. ohm C. watt D. ampere

28 /Reference: QUESTION 93 The National Electrical Code (NEC) required that power-limited circuits are supplied by a source with a rated output of no more than: A. 15 volts B. 30 volts C. 120 volts D. 240 volts /Reference: QUESTION 94 A technician is running data communication Unshielded Twisted Pair (UTP) wire in a new construction home. To prevent signal degradation, the minimum distance between t he communications cable and the electrical cable should be. A. 5 in. B. 10 in. C. 12 in. D. 16 in. /Reference: QUESTION 95 Remote control and signaling circuits are classified by the National Electrical Code (NEC) according to the. A. type of wire used B. wire termination method C. location of the equipment D. limitation of the power supply /Reference: QUESTION 96

29 A client desires a home technology system that will primarily by used for controlling household appliances. In the future, the client plans to add components that will be used to control lighting. Which of the following is the most cost-effective solution for the technician to install? A. UTP cabling B. STP cabling C. RG-59 coaxial cabling D. Powerline carries to the existing AC wiring /Reference: QUESTION 97 A technician is asked to connect two computers to enable file sharing on an Ethernet network. Which of the following types of cables would be used to connect the computers without a hub or switch? A. 10Base-T through cable B. 10Base-T crossover cable C. 10Base2 Thinnet coaxial cable D. 10Base5 Thicknet coaxial cable /Reference: QUESTION 98 Which of the following types of cables is the MOST expensive to install? A. Coaxial B. Fiber-optic C. Shielded Twisted Pair (STP) D. Unshielded Twisted Pair (UTP) /Reference: QUESTION 99 The proper cable o be used in connecting a Direct Broadcast Satellite (DBS) dish to a receiver is A. B. Romex cable C. Category D. sweep-tested RG-6 E. 16 AWG speaker wire

30 /Reference: QUESTION 100 In the data wiring considerations for a new home, which of the following central termination interfaces provides the MOST flexible and LEAST expensive solution for moves, adds, and changes? A. Intermediate Distribution Facility (IDF) B. Patch panel C. M-150 Block D. Main Distribution Facility (MDF) /Reference: QUESTION 101 Which of the following techniques best describes the type of wireless network installed for a wireless networking solution that uses the IEEE standards? A. X10 B. HPNA C. Appletalk D. Ethernet /Reference: QUESTION 102 A computer is used to automate the control of the audio/video system. The components include the following connections: * RCA type A/V jacks * Infra-red remote control port * F-type input and out connectors * USB To integrate these components with a minimum of cabling, the computer should be equipped with: A. To integrate these components with a minimum of cabling, the computer should be equipped with: B. USB ports C. RCA A/V jacks D. IEEE 1394 ports

31 /Reference: QUESTION 103 Which of the following DSL standards has the geatest maximum downstream speed? A. G.lite B. SDSL C. HDSL D. G.SHDSL /Reference: QUESTION 104 Which of the following devices is used to protect an alarm circuit against accidental shorts or opens? A. Key switch B. Fuseable link C. End-of-line resistor D. Tamper-reinstant connector /Reference: QUESTION 105 Which of the following versions of the National Electrial Code (NEC) is valid in a given area? A. The one most recently published, except any portions overwritten or extended by state governments? B. The one most recently published, except any portioins overwritten or extended by the federal government. C. The one most recently accepted by local government, except any portions overwritten or extended by local government. D. The one most recently accepted by the federal government, except any portions overwritten or extended by the federal government. /Reference: QUESTION 106 The proper installation of a Direct Broadcast Satellite (DBS) dish includes: A. using 16 AWG speaker wire

32 B. aiming the dish at the North Star C. shielding from ground-based radar D. establishing earth ground connection at the dish /Reference: QUESTION 107 Which of the following is a requirement of a home automation system that allows the system to be set up for remote maintenance from an off-site location? A. Dial-in-modem B. Local terminal C. Infrared remote D. Wireless access point /Reference: QUESTION 108 Which of the following is necessary for a wireless two-way touch panel? A. RF B. Relay C. RS-232 D. RS-422 /Reference: QUESTION 109 Which of the following is the major advantage of using RG-6 cable over RG-59? A. Lower cost. B. Higher bandwidth. C. Thicker center conductor. D. Higher attenuation per foot. /Reference:

33 QUESTION 110 Which of the following devices is used to trace wiring and locate specific wires? A. Digital millimeter. B. Time Domain Reflectometer (TDR). C. Signal generator and oscilloscope. D. Tone generator and inductive amplifier. /Reference: QUESTION 111 According to the EIA/TIA 570 standard, which of the following cables is the minimum grade required for a home computer network? A. Category 3 B. Category 5 C. One pair flat telephone D. Two pair flat telephone /Reference: QUESTION 112 Which of the following is a type of wireless personal computer keyboard connection? A. RF B. DIN C. COM D. USB /Reference: QUESTION 113 A circuit breaker is a device designed to: A. automatically open and close, and manually open a circuit B. automatically open and close, and manually close a circuit C. manually open and close, and automatically open a circuit D. manually open and close, and automatically close a circuit

34 /Reference: QUESTION 114 Which of the following is a typical U.S. household electrical current? A. AC/120 volt. 60 Hz B. DC/120 volt C. AC/120 volt 50 Hz D. DC/240 volt /Reference: QUESTION 115 Which of the following types of cables is required for wiring a digital satellite dish? A. RG-6 B. RG-11 C. RG-58 D. RG-59 /Reference: QUESTION 116 The maximum length for Category 5 cable is: A. 50 meters B. 75 meters C. 100 meters D. 125 meters /Reference: QUESTION 117 The maximum measured voltage appearing across a surge protector when a standard waveform is applied is referred to as:

35 A. bleed voltage B. clamp voltage C. threshold voltage D. let-through voltage /Reference: QUESTION 118 All of the following are typical rough-in-pre-wire tasks EXCEPT: A. marking locations B. preparing cable runs C. pulling and labeling cables D. installing outlet cover plates /Reference: QUESTION 119 Which of the following types of jacks is typically used for an analog modem? A. RG-6 B. RG-58 C. RJ-11 D. RJ-45 /Reference: QUESTION 120 All of the following are used as personal computer keyboard connectors EXCEPT. A. infrared B. centronics parallel C. Radio Frequency (RF) D. Universal Serial Bus (USB)

36 /Reference: QUESTION 121 Which of the following categories of cable can handle a maximum transmission frequency of 100 MHz? A. 2B. 3 B. 4 C. 5 /Reference: QUESTION 122 A device designed to protect a person from electrocution when contact between a live protected circuit and ground causes current to flow through a person's body is called A. A. knife switch B. circuit breaker C. phase protector D. ground-fault circuit interrupter /Reference: QUESTION 123 In order for devices to communicate and integrate over the homelan infrastructure, the home integrator should ideally connect at the associated sub-systems? A. end devices B. control panel C. distribution panel D. residential gateway /Reference: QUESTION 124 Which of the following is the term used for the wiring runs from the distribution device to the wall jack in each of the outlet locations: A. Vertical B. Backbone

37 C. Horizontal D. Plenum /Reference: QUESTION 125 The installation of a whole house X10-based system is complete. To protect the equipment, all of the A/V components and computers are connected to the household wiring by using surge suppressors. The client calls and states that none of the A/V system parts will operate from any of the X10 controllers. The equipment operates manually and other devices are operating normally. Which of the following steps should the technician take first? A. Repair the AC wiring. B. Reprogram the controller. C. Replace the surge suppressors. D. Install a multiphase blocking coupler. /Reference: QUESTION 126 Which of the following DSl standards has the lowest maximum upstream speed. A. ADSL B. G.lite C. HDSL D. SDSL /Reference: QUESTION 127 Which of the following terms is NOT used to describe the power of a projector bulb? A. Watts B. Amps C. Hours D. Lumens

38 /Reference: QUESTION 128 Which of the following types of sensors is most commonly used for occupancy detection? A. Laser B. Ultrasonic C. Retro-reflective D. Passive infrared /Reference: QUESTION 129 Which of the following is a split-support that is mounted to the backboard or rack and used to manage cables? A. Conduit B. 66 block C. Bridle ring D. Cabling tray /Reference: QUESTION 130 A controller with a built-in Web server is configured to control a home automation system. If a remote computer is used to access this system, it must be equipped with: A. an FTP client B. a Web browser C. terminal software D. remote control software /Reference: QUESTION 131 Which of the following control interfaces allows a customer to control a receiver that is 150 ft. from the central controller? A. RF

39 B. RS-232 C. RS-422 D. S-Link /Reference: QUESTION 132 Which of the following types of connectors is used to connect two male terminated RG-6 coaxial cables? A. Barral. B. RG-59 C. F-Male of F-Male. D. F-Female to RCA Male. /Reference: QUESTION 133 All of the following are considerations when a home technology integration system is designed EXCEPT: A. control system B. climate control C. client preferences D. type of building construction /Reference: QUESTION 134 Unshielded Category 5 cable crossing over an electric cable or fluorescent light can cause. A. attenuation B. crosstalk C. reflection D. termination /Reference:

40 QUESTION 135 A wiring defect that permits current to jump from one wire to another before the intended path has been completed is called. A. a sheath B. a short C. a farad D. an interference /Reference: QUESTION 136 Which of the following may NOT be used to control equipment in a home automation system? A. RS-232 B. Infrared (IR) C. Video sync D. Contact closure /Reference: QUESTION 137 The National Electrical Code (NEC) states that all exposed non-current-carrying metal parts of a low-voltage system must be double insulated or: A. clean B. covered C. painted D. grounded /Reference: QUESTION 138 Which of the following types of cables is the LEAST expensive to install? A. Coaxial B. Fiber-optic C. Shielded Twisted Pair (STP) D. Unshielded Twisted Pair (UTP)

41 /Reference: QUESTION 139 The National Electrical Code (NEC) specifies that the maximum resistance to ground is: A. 10 ohms B. 25 ohms C. 35 ohms D. 40 ohms /Reference: QUESTION 140 Which of the following represents a structured connection from a distribution panel to the final termination point? A. Loop B. Wireless C. Home run D. Daisy chain /Reference: QUESTION 141 The control system uses an embedded HTTM server to provide accessing to programs and control functions. The client states that the system can no longer be accessed. Which of the following commands should be technician use to verify connectivity to the server? A. ping B. path C. nestat D. nslookup /Reference:

42 QUESTION 142 The IEEE wireless protocol standard operates in: A. low frequency B. high frequency C. spread spectrum D. shared channel /Reference: QUESTION 143 The National Electrical Code (NEC) is published in an updated edition every? A. 18 months B. 24 months C. 30 months D. 36 months /Reference: QUESTION 144 After installing a Category 5 data drop, the wire map test fails showing the cable to have an open and a split pair. Which of the following should the technician perform first to correct this problem? A. Replace the Category 5 cable. B. Check the wire run for breaks. C. Replace the Category 5 jack. D. Check the cable for proper termination. /Reference: QUESTION 145 Which of the following is the term used for the wiring runs from the wiring closet above the ceiling to the wall jack in each of the office locations? A. Vertical. B. Backbone. C. Horizontal. D. Home run.

43 /Reference: QUESTION 146 The term "ground fault" refers to a current that. A. Fails to flow at all. B. Flows inside the normal circuit path. C. Flows outside the normal circuit path. D. Fails to flow outside the normal circuit path. /Reference: QUESTION 147 Which of the following pairs of copper wire gauges would be specified for lighting or outlet wiring installations? A. 6 and 8 B. 8 and 10 C. 10 and 12 D. 12 and 14 /Reference: QUESTION 148 Which of the following connector types would NOT be found on a structured wiring system? A. F B. RCA C. DB-15 D. RJ-45 /Reference: QUESTION 149 he IEEE 1394 port is a good choice for integrating consumer A/V and media devices because it supports data transfer rates as high as:

44 A. 200 Mbps B. 400 Mbps C. 600 Mbps D. 800 Mbps /Reference: QUESTION 150 Which of the following modular outlet configurations is used to terminate the cable conductors when a fourposition, four-conductor modular connector is used? A. USOC B. T568B C. T568A D. IDC /Reference: QUESTION 151 Which of the following devices uses Wireless Application Protocol (WAP)? A. Cordless phone B. Remote control C. Keyless entry card D. Personal Digital Assistant (PDA) /Reference: QUESTION 152 A design requires that a laptop, PDA, Web-enabled phone, or any computer with Internet access can be used to monitor and control the home. Which of the following features should the controller include? A. Integrated Web server B. RF remote control C. If remote control D. Terminal access

45 /Reference: QUESTION 153 When Category 5 cable is installed, the maximum pull force is. A. 20 lbs. B. 25 lbs. C. 30 lbs. D. 35 lbs. /Reference: QUESTION 154 Which of the following color pairs does NOT occupy consecutive pins in a Category 5 cable wired to the 568B specification? A. Blue/blue and white B. Brown/brown and white C. Green/green and white D. Orange/orange and white /Reference: QUESTION 155 A light that needs to be controlled from two locations requires a minimum of. A. two 3-way switches B. two single-pole switches C. one 4-way switch and one 3-way switch D. one 3-way switch and one single-pole switch /Reference: QUESTION 156 When a technician wires for a High Definition Television (HDTV) satellite dish, all of the following are factors to be considered EXCEPT: A. compass angle

46 B. unobstructed view C. height from ground D. number and type of cable /Reference: QUESTION 157 Which of the following types of cables has the LEAST resistance to interference? A. Coaxial B. Fiber-optic C. Shielded Twisted Pair (STP) D. Unshielded Twisted Pair (UTP) /Reference: QUESTION 158 Which of the following serial protocols allows the daisy chaining of devices? A. MIDI B. RS-232 C. RS-422 D. RS-485 /Reference: QUESTION 159 Which of the following describes the X10 protocol? A. IR control of up to 256 devices B. UHF control of up to 144 devices C. Powerline control of upto 256 devices D. Ethernet control of upto 1,024 devices /Reference:

47 QUESTION 160 Which of the following types of systems uses an RJ-31X jack with twisted-pair cabling? A. Satellite B. Home audio C. Home security D. Energy management /Reference: QUESTION 161 Which of the following individuals should sign off on all acceptance testing? A. Owner's representative B. Vendor representative C. Lead electrician D. Contactor /Reference: QUESTION 162 Which of the following devices should be used to program a Central Control Unit (CCU) by using its serial port? A. Notebook computer B. RF remote control C. Infrared remote D. Web browser /Reference: QUESTION 163 Standard Ethemet operates at which of the following data transfer speeds? A Kbps. B Mbps. C. 10 Mbps. D Mbps.

48 /Reference: QUESTION 164 The term "Electrical transient refers to A. A. Sag. B. Spike. C. Blackout. D. Brownout. /Reference: QUESTION 165 Which of the following does NOT need to be addressed when a technician perform a pre-wire walk through? A. Outlet design B. Panel design C. Outlet location D. Panel location /Reference: QUESTION 166 Which of the following agencies inspects and regulates to protect workers against job-site hazards? A. Federal Trade Commission (FTC) B. National Fire Protection Association (NFPA) C. Occupational Safety and Health Administration (OSHA) D. International Brotherhood of Electrical Workers (IBEW) /Reference: QUESTION 167 Which of the following control interfaces, without repeaters, allows a customer to control a receiver that is 150 ft. from the central controller? A. IR

49 B. RS-232 C. RS-422 D. S-Link /Reference: QUESTION 168 The term "Ohm" is defined a unit of electrical. A. Reactance. B. Reluctance. C. Resistance. D. Resonance. /Reference: QUESTION 169 A device that combine different signal types into a single able is: A. a repeater B. an amplifier C. a multiplexer D. a POTS splitter /Reference: QUESTION 170 The purpose of the National Electrical Code (NEC) is to: A. Standardize electrical product manufacturing. B. Regulate power usage throughout the United States. C. Standee electrical voltage throughout the United States. D. Set safety standards for electrical design construction and maintenance. /Reference: : The most widely adopted element of a building code in the United States and the world, NFPA 70,

50 National Electrical Code (NEC) is the benchmark for safe and efficient electrical installations. Source:

KillTest. 半年免费更新服务

KillTest.   半年免费更新服务 KillTest 质量更高 服务更好 学习资料 http://www.killtest.cn 半年免费更新服务 Exam : HT0-102 Title : HTI+ Systems Infrastructure and Integration Version : DEMO 1 / 5 1.Which of the following serial protocols allows the daisy

More information

3 Chapter Introduction. 3.2 Copper Cable

3 Chapter Introduction. 3.2 Copper Cable 3 Chapter 3 3.1 Introduction The Network Media is the device that physically carries the data from computer to computer. The three major types of network media are: Copper Cable Fiber-Optic Cable Wireless

More information

A+ Guide to Managing & Maintaining Your PC, 8th Edition. Chapter 16 Networking Types, Devices, and Cabling

A+ Guide to Managing & Maintaining Your PC, 8th Edition. Chapter 16 Networking Types, Devices, and Cabling A+ Guide to Managing & Maintaining Your PC, Chapter 16 Networking Types, Devices, and Cabling Objectives Learn about network types and topologies Learn about the hardware used to build local networks Learn

More information

Physical Layer V What does the physical layer provide?

Physical Layer V What does the physical layer provide? SEMESTER 1 Chapter 8 Physical Layer V 4.0 90 Points 8.1.1 What does the physical layer provide? What are the four elements of delivering frames across the media? 8.1.2 What are the three basic forms of

More information

Network Media and Layer 1 Functionality

Network Media and Layer 1 Functionality Network Media and Layer 1 Functionality BSAD 146 Dave Novak Dean, Chapter 3, pp 93-124 Objectives Introduction to transmission media Basic cabling Coaxial Twisted pair Optical fiber Basic wireless (NIC)

More information

Networking Fundamentals

Networking Fundamentals Networking Fundamentals Cable types and connectors Fiber A fiber optic cable consists of a bundle of glass threads, each of which is capable of transmitting messages modulated onto light waves. Fiber optics

More information

Cables and Connectors

Cables and Connectors Module 2 Cables and Connectors Twisted Pair Two wires that carry the data signals (one conductor carries a positive signal; one carries a negative signal). Two wires are twisted to reduce the effects of

More information

Computer Networks. Week 04 Media and Devices. College of Information Science and Engineering Ritsumeikan University

Computer Networks. Week 04 Media and Devices. College of Information Science and Engineering Ritsumeikan University Computer Networks Week 04 Media and Devices College of Information Science and Engineering Ritsumeikan University Network Media and Devices l When you build a network, the network hardware may be used

More information

with its cables, connectors, Switches, Hubs and topologies

with its cables, connectors, Switches, Hubs and topologies Introduction to LAN www.mycsvtunotes.in with its cables, connectors, Switches, Hubs and topologies LAN Small interconnected computers or workstations within a building or small area up to 10 Kms. Small

More information

Tarleton State University. Specifications

Tarleton State University. Specifications Tarleton State University Campus Communication Infrastructure Specifications Cabling Standards Summary This document identifies Tarleton State University communication infrastructure standards. The communication

More information

Physical Layer Part 3

Physical Layer Part 3 Physical Layer Part 3 Transmission Media Computer Networks: Transmission Media 1 Transmission Media Transmission medium:: the physical path between transmitter and receiver. Repeaters or amplifiers may

More information

Upon completing this chapter, you will be able to: Describe the primary types and uses of twisted-pair cables Describe the primary types and uses of

Upon completing this chapter, you will be able to: Describe the primary types and uses of twisted-pair cables Describe the primary types and uses of Upon completing this chapter, you will be able to: Describe the primary types and uses of twisted-pair cables Describe the primary types and uses of coaxial cables Describe the primary types and uses of

More information

ANSI/TIA/EIA-568-B Cabling Standard

ANSI/TIA/EIA-568-B Cabling Standard 83 Pair Numbers and Color Coding The conductors in a UTP cable are twisted in pairs and color coded so that each pair of wires can be easily identified and quickly terminated to the appropriate pin on

More information

Section 1.1: Networking Overview

Section 1.1: Networking Overview Section 1.1: Networking Overview This section provides an introduction to networking. Students will become familiar with the following aspects of a network: Components of a network o Computers o Transmission

More information

Physical Layer Part 3

Physical Layer Part 3 Physical Layer Part 3 Transmission Media Networks: Transmission Media 1 Transmission Media Transmission medium:: the physical path between transmitter and receiver. Repeaters or amplifiers may be used

More information

Cabling Infrastructure

Cabling Infrastructure Introduction Ethernet Banking on Structured Cabling Technology Drivers Classification of Cables Fibre-optic cable Cables in building Cabling Infrastructure Cabling systems address the networking requirements

More information

Review: Networking Fall Final

Review: Networking Fall Final Review: Networking Fall Final Question 1 of 43 You have implemented a network where each device provides shared files with all other devices on the network. What type of network do you have? Peer to peer

More information

Physical Layer Part 3

Physical Layer Part 3 Physical Layer Part 3 Transmission Media Networks: Transmission Media 1 Transmission Media Transmission medium:: the physical path between transmitter and receiver. Repeaters or amplifiers may be used

More information

Lecture (07) Media & Switching III Ethernet Protocol & Network Hardware Components

Lecture (07) Media & Switching III Ethernet Protocol & Network Hardware Components Lecture (07) Media & Switching III Ethernet Protocol & Network Hardware Components By: Dr. Ahmed ElShafee ١ Agenda Ethernet Protocol Physical layer Physical layer devices The Data Link Layer ٢ Ethernet

More information

(Network Programming) Basic Networking Hardware

(Network Programming) Basic Networking Hardware EEE 448 Computer Networks with (Network Programming) Basic Networking Hardware Lecture #2 Dept of Electrical and Electronics Engineering Çukurova University Agenda What is a network device? Network Media

More information

Multiplexing (Recap)

Multiplexing (Recap) Multiplexing (Recap) Multiplexing How to transfer data between two sites once there is a digital link between them? Analog to Digital (A2D) conversion Human voice is a continuous signal in the range 0-4

More information

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) Site Preparation Guide This guide is designed to assist local on-site contacts to understand what you will need to

More information

Lecture (03) Ethernet Protocol & Network Hardware Components

Lecture (03) Ethernet Protocol & Network Hardware Components Lecture (03) Ethernet Protocol & Network Hardware Components Dr. Ahmed M. ElShafee 1 Agenda Ethernet Protocol/ and cable types Network interface card Network nodes Servers Clients Storage area network

More information

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) Site Preparation Guide 2015 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T

More information

f) Telecommunications Equipment Rooms

f) Telecommunications Equipment Rooms SECTION 270000 - COMMUNICATIONS PART 1 - GENERAL 1.1 GENERAL REQUIREMENTS A. The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification

More information

Transmission Media. Criteria for selection of media. Criteria for selection of media 2/17/2016. Chapter 3: Transmission Media.

Transmission Media. Criteria for selection of media. Criteria for selection of media 2/17/2016. Chapter 3: Transmission Media. Chapter 3: Transmission Media Marks- 20 Transmission Media Transmission media carries the information from sender to receiver. Different types of cables or waves to transmit data. Data is transmitted through

More information

Twisted Pair Cable Testers Int l Phone

Twisted Pair Cable Testers Int l Phone Twisted Pair Cable Testers Int l Phone 001.804.550.1121 Main LAN ProNavigator Tester & Remote If you re a technician on the go, you need the LAN ProNavigator from Paladin Tools! Two-piece tester includes

More information

Network basics. Unit objectives Describe the basic components of a network Identify characteristics of network technologies Analyze the OSI model

Network basics. Unit objectives Describe the basic components of a network Identify characteristics of network technologies Analyze the OSI model Network basics Unit objectives Describe the basic components of a network Identify characteristics of network technologies Analyze the OSI model Topic A Topic A: Network concepts Topic B: Network architectures

More information

A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e. Chapter 10 Networking Essentials

A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e. Chapter 10 Networking Essentials A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e Chapter 10 Networking Essentials Objectives Learn about hardware devices used for networking Learn about the different types of networks

More information

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The

More information

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO Cabling Standards Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO 1. Purpose CABLING STANDARDS This technical note

More information

Communications. UNM IT/Telecommunications Guide Specification Communications

Communications. UNM IT/Telecommunications Guide Specification Communications The material below covers specific information we definitely want to be included in the contract documents and may not be a completed specification section. This material is to be highlighted in your preliminary

More information

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120 DESIGN GUIDELINES PRESTO INSTALLATION & CONNECTIVITY PAGE 1 of 4 ELECTRICAL CONNECTIVITY AND WIRING Communications Conduits Conduits designated for Presto equipment data wiring shall be clearly identified

More information

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling Page 1 of 7 Title Demonstrate basic knowledge of electronic security data protocols and cabling Level 3 Credits 15 Purpose This unit standard is for electronic security installers engaged in the installation

More information

Experiment # 2 Transmission Media & Networking Components

Experiment # 2 Transmission Media & Networking Components Experiment # 2 Transmission Media & Networking Components Objectives: Study different types of networking cables, connectors and other network components. Transmission Media (refer to text book, sec 3.7)

More information

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual 10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1

More information

A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e. Chapter 10 Networking Essentials

A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e. Chapter 10 Networking Essentials A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e Chapter 10 Networking Essentials Objectives Learn about hardware devices used for networking Learn about the different types of networks

More information

Demonstrate and apply knowledge of computer networking infrastructure principles

Demonstrate and apply knowledge of computer networking infrastructure principles Demonstrate and apply knowledge of computer networking infrastructure principles 22713 version 1 Page 1 of 5 Level 4 Credits 15 Purpose This unit standard covers the necessary introductory skills required

More information

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT 4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with

More information

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

end systems, access networks, links circuit switching, packet switching, network structure

end systems, access networks, links circuit switching, packet switching, network structure Introduction Chapter 1: roadmap 1.1 What is the Internet? 1.2 Network edge end systems, access networks, links 1.3 Network core circuit switching, packet switching, network structure 1.4 Delay, loss and

More information

Ethernet 10Base-T Hub EH-500 EH-800A EH Rev. 3.0

Ethernet 10Base-T Hub EH-500 EH-800A EH Rev. 3.0 Ethernet 10Base-T Hub EH-500 EH-800A EH-1600 Rev. 3.0 Trademarks Copyright PLANET Technology Corp. 1998. PLANET is a registered trademark of PLANET Technology Corp. The information in this manual is subject

More information

Specifications for Modular Sound Shadow Sound Masking Sound Management Group, LLC.

Specifications for Modular Sound Shadow Sound Masking Sound Management Group, LLC. Specifications for Modular Sound Shadow Sound Masking Sound Management Group, LLC. 1.01 General Requirements This section details general requirements for plenum sound masking installations. 1.1 Contract

More information

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual 4-port 10/100TX + 1 or 2-port 100FX Industrial Switch User Manual Rev.1.03 Sep-2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant

More information

DVI Extender over Single CAT5 Model #: DVI-C5-M-SET

DVI Extender over Single CAT5 Model #: DVI-C5-M-SET DVI Extender over Single CAT5 Model #: DVI-C5-M-SET 2013 Avenview Inc. All rights reserved. The contents of this document are provided in connection with Avenview Inc. ( Avenview ) products. Avenview makes

More information

ex-s1110-xt Gigabit Ethernet Extenders

ex-s1110-xt Gigabit Ethernet Extenders ex-s1110- Gigabit Ethernet Extenders perle.com/products/10-100-1000-industrial-ethernet-extender.shtml 10/100/1000 Industrial Temperature Copper Extender Extends 10/100/1000Base-T Ethernet up to 10,000

More information

HITEC 2003 Produced by Hospitality Financial and Technology Professionals

HITEC 2003 Produced by Hospitality Financial and Technology Professionals Infrastructure of a Hotel Dan Phillips Bob Stoutenburgh David Hostetter Presenters Dan Phillips Founding partner and COO of ITS Inc., Dan manages and organizes telecommunications and data projects for

More information

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input. LNP-0500-24 series 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input User Manual FCC Warning This Equipment has been tested and found to comply with

More information

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express AT&T Virtual Private Network Service (VPN) and AT&T VPN Express Site preparation guide This guide is designed to assist local on-site contacts to understand what you will need to accomplish in preparation

More information

Networking Jamie Tees

Networking Jamie Tees Ethernet is the main networking technology, UTP (Unshielded Twisted Pair) cabling is the main networking cable types, this cabling uses RJ-45 connectors either end. While UTP is the main type we have STP

More information

COMPUTER SKILLS COMP101

COMPUTER SKILLS COMP101 COMPUTER SKILLS COMP101 Chapter 4 Introduction to Computer Networks Definitions and Terminologies Computer Network A network consists of two or more computers that are linked in order to share resources

More information

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch SAM-SW5U: 5-port 10/100 Ethernet Switch 1. Introduction The 5 port 10/100BASE-TX Switch is compact and attractively designed for use within Suttle s SOHO Access TM Enclosure. They are ideal solution for

More information

Cable TV, Broadband, Telephone, and Security

Cable TV, Broadband, Telephone, and Security Chapter 7 Cable TV, Broadband, Telephone, and Security Because of the increasingly widespread use of communications and security systems over the past two decades, electricians have been called upon to

More information

ANSI/TIA/EIA-568-B Cabling Standard

ANSI/TIA/EIA-568-B Cabling Standard 73 ANSI/TIA/EIA-568-B Cabling Standard In the mid-1980s, consumers, contractors, vendors, and manufacturers became concerned about the lack of specifications relating to telecommunications cabling. Before

More information

Connector and Cable Specifications

Connector and Cable Specifications APPENDIX B This appendix describes the pinouts and cabling requirements for the interfaces and cables used on the Cisco ubr925 cable access router. All connectors for these interfaces are on the rear-panel,

More information

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual Lantech IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to

More information

CTS2134 Introduction to Networking. Module : Troubleshooting

CTS2134 Introduction to Networking. Module : Troubleshooting CTS2134 Introduction to Networking Module 10.1 10.3: Troubleshooting Troubleshooting Methodology Facts 1. Identify the symptoms and potential causes. 2. Identify the affected area and determine how large

More information

INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET

INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET 1 Contents ETHERNET Switches ECO and Standard 3 4 SFP Modules Interface for Fiber-Optic 5 ETHERNET Switches Managed 6

More information

Transmission Media :- It can be broadly classified into two types

Transmission Media :- It can be broadly classified into two types Transmission Media :- It can be broadly classified into two types - Guided Transmission Media:- in this type of media, a physical path is established between source and destination. The signal or electrical

More information

Lecture #25: Networks and Communications. Communication and Networks. What will we learn?

Lecture #25: Networks and Communications. Communication and Networks. What will we learn? Lecture #25: Networks and Communications Communication and Networks What will we learn? How a communications system works What a network is What networks used for What network operating systems do What

More information

Wireless Area Controller (WAC60)

Wireless Area Controller (WAC60) Installation Instructions The Daintree WAC60 Wireless Area Controller (WAC) is at the heart of the Daintree wireless controls solution for smart buildings. It provides intelligent control across a large

More information

Network+ Guide to Networks 7 th Edition

Network+ Guide to Networks 7 th Edition Network+ Guide to Networks 7 th Edition Chapter 4 Structured Cabling and Networking Elements 2016 Cengage Learning. May not be scanned, copied or duplicated, or posted to a publicly accessible website,

More information

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM 1993 SPECIFICATIONS CSJ 1685-05-068, ETC. & 1685-02-042 1.0 DESCRIPTION SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM THIS ITEM DESCRIBES THE OPERATION AND INSTALLATION OF AN ARTERIAL

More information

TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch. User s Guide

TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch. User s Guide TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch User s Guide FCC Warning This equipment has been tested and found to comply with the regulations for a Class A digital device, pursuant to Part 15 of the

More information

Chapter 4: Network Access

Chapter 4: Network Access 4.0.1.1 Chapter 4: Network Access To support our communication, the OSI model divides the functions of a data network into layers. Each layer works with the layers above and below to transmit data. 4.0.1.2

More information

COMPUTER NETWORK WIRING SYSTEMS FOR PLCs

COMPUTER NETWORK WIRING SYSTEMS FOR PLCs SECTION 13744 COMPUTER NETWORK WIRING SYSTEMS FOR PLCs NOTE TO SPECIFIER: This section applies to primary learning centers only. PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete computer network

More information

Protect It! 8-Outlet A/V Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Modem/Coax Protection

Protect It! 8-Outlet A/V Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Modem/Coax Protection Protect It! 8-Outlet A/V Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Modem/Coax Protection MODEL NUMBER: AV810 Highlights 8 outlets / 10-ft. cord with space saving right angle plug 3240 joule rating

More information

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual 8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a

More information

Number: Passing Score: 750 Time Limit: 120 min File Version: 1.0. Microsoft Exam Name: Identity with Windows Server 2016 (beta)

Number: Passing Score: 750 Time Limit: 120 min File Version: 1.0. Microsoft Exam Name: Identity with Windows Server 2016 (beta) 70-742 Number: 70-742 Passing Score: 750 Time Limit: 120 min File Version: 1.0 Microsoft 70-742 Exam Name: Identity with Windows Server 2016 (beta) Sections 1. Understanding Local Area Networks 2. Defining

More information

WS must be used in a temperature controlled place. It is compliant to ETS Class T

WS must be used in a temperature controlled place. It is compliant to ETS Class T Important Information about the Sagemcom F@ST 2705 WS: Operational working: F@ST2705 WS must be used in a temperature controlled place. It is compliant to ETS 300 019-1-3 Class T 3.2 standard: 1. Temperature

More information

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual LNP-0602 series 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A

More information

TCP/IP and OSI Model Ethernet LAN Network Cables Network Devices Network Topologies Redundant Internet Connections VLANs Wireless LANs Upcoming

TCP/IP and OSI Model Ethernet LAN Network Cables Network Devices Network Topologies Redundant Internet Connections VLANs Wireless LANs Upcoming 2 TCP/IP and OSI Model Ethernet LAN Network Cables Network Devices Network Topologies Redundant Internet Connections VLANs Wireless LANs Upcoming Network Technologies 3 4 Elements of the Network Sender

More information

Los Angeles Community College District Design Standards

Los Angeles Community College District Design Standards LACCD Facilities Design Standards - Structural Cabling and Telecommunications Room Facilities Ver Approved: DTC February 0, 0 LACCD has developed the following Districtwide standard for IT infrastructure

More information

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

General Description. Product Application. Eaton Innovative Technology Special Applications

General Description. Product Application. Eaton Innovative Technology Special Applications Eaton Innovative Technology Special s Technical Data New Information Page General.............................................. 1 Product.............................................. 1 Dedicated Load

More information

Chapter 9 Introduction to Networks

Chapter 9 Introduction to Networks Chapter 9 Introduction to Networks 9.1 Uses of a network Networks are used in many situations. We can see networks in places like offices, airports and factories. In fact we use networks in many situations

More information

Contents. Introduction to Networking. Preface...i. Introduction... xix

Contents. Introduction to Networking. Preface...i. Introduction... xix Contents Introduction to Networking Introduction to Networking Preface...i Key Topics...i Course Objectives...ii Pedagogical Features...ii Learning Objectives, Unit Summaries, Discussion Questions, and

More information

Application of Cable Assembly

Application of Cable Assembly Total Solution and Application of Cable Assembly ITEM Functions Txxpo Pxxxdxn FXXKE Pro skit MT-7068 Transmitter 1KHz 1KHz 1KHz 1KHz Tone Mode TWO (Hi/Lo) TWO (Hi/Lo) TWO (Hi/Lo) TWO (Hi/Lo) Compatible

More information

HDMI 1.3 Matrix Switch Receiver over CAT5 with IR Pass-Through

HDMI 1.3 Matrix Switch Receiver over CAT5 with IR Pass-Through HDMI 1.3 Matrix Switch Receiver over CAT5 with IR Pass-Through Model #: HDMI-C5SW-R 20010 Avenview Inc. All rights reserved. The contents of this document are provided in connection with Avenview Inc.

More information

Objectives. Learn how computers are connected. Become familiar with different types of transmission media

Objectives. Learn how computers are connected. Become familiar with different types of transmission media Objectives Learn how computers are connected Become familiar with different types of transmission media Learn the differences between guided and unguided media Learn how protocols enable networking 2 Objectives

More information

Leveraging the Structured Cabling System for Security Applications. Mark Dearing, RCDD Leviton Network Solutions

Leveraging the Structured Cabling System for Security Applications. Mark Dearing, RCDD Leviton Network Solutions Leveraging the Structured Cabling System for Security Applications Mark Dearing, RCDD Leviton Network Solutions Trends - Cable Category Mix Source: Leviton projections based on market growth rates Over

More information

Copyright Black Box Corporation. All rights reserved.

Copyright Black Box Corporation. All rights reserved. Copyright 2000. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 JUNE 2000 SP141A SP501A SP508A SP515A-R2 SP523A-R2 SP604A SP350A-R2 SP502A

More information

Media and Access Method. Tory Klementsen, MCP A+ Sno Isle Skill Center Network+ Module 2

Media and Access Method. Tory Klementsen, MCP A+ Sno Isle Skill Center Network+ Module 2 Media and Access Method Tory Klementsen, MCP A+ Sno Isle Skill Center Network+ Module 2 Transmission Media The stuff that carries signals from computer to computer or device on a network. Different media

More information

2X8 HDMI 1.3 Extender / Splitter over Single CAT5

2X8 HDMI 1.3 Extender / Splitter over Single CAT5 2X8 HDMI 1.3 Extender / Splitter over Single CAT5 Model #: HDM-C5SP-8 2009 Avenview Inc. All rights reserved. The contents of this document are provided in connection with Avenview Inc. ( Avenview ) products.

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

TEX-100. Ethernet Extender User Manual

TEX-100. Ethernet Extender User Manual TEX-100 Ethernet Extender User Manual Version 2.00 March 2014 1 Table of Contents Chapter 1 Introduction...3 1.1 Features...4 1.2 Specification...5 1.3 Applications... 5 Chapter 2 Hardware Installation...7

More information

Introduction to LAN Topologies Cabling. 2000, Cisco Systems, Inc. 3-1

Introduction to LAN Topologies Cabling. 2000, Cisco Systems, Inc. 3-1 Introduction to LAN Topologies Cabling 2000, Cisco Systems, Inc. 3-1 Objectives Upon completion of this chapter, you will be able to perform the following tasks: Media / Cabling Local Area Network Cabling

More information

Telecommunications Structured Cabling Systems

Telecommunications Structured Cabling Systems Section 18 Telecommunications Structured Cabling Systems 18.1.0 Introduction 18.1.1 Important Codes and Standards 18.1.2 Comparison of ANSI/TIA/EIA, ISO/IEC, and CENELEC Cabling Standards 18.2.0 Major

More information

Course Outline 11/6/ Santa Teresa Blvd Gilroy, CA COURSE: CSIS 274 DIVISION: 50 ALSO LISTED AS: SHORT TITLE: TELECOM/NETWK CABLE

Course Outline 11/6/ Santa Teresa Blvd Gilroy, CA COURSE: CSIS 274 DIVISION: 50 ALSO LISTED AS: SHORT TITLE: TELECOM/NETWK CABLE 5055 Santa Teresa Blvd Gilroy, CA 95020 Course Outline COURSE: CSIS 274 DIVISION: 50 ALSO LISTED AS: TERM EFFECTIVE: Fall 2011 Inactive Course SHORT TITLE: TELECOM/NETWK CABLE LONG TITLE: Telecommunication

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

CCNA 1 Chapter 5. Cabling LANs and WANs

CCNA 1 Chapter 5. Cabling LANs and WANs CCNA 1 Chapter 5 Cabling LANs and WANs Overview Even though each local-area network is unique, there are many design aspects that are common to all LANs. For example, most LANs follow the same standards

More information

Network Devices. March 6, Copyright 2011 by World Class CAD, LLC. All Rights Reserved.

Network Devices. March 6, Copyright 2011 by World Class CAD, LLC. All Rights Reserved. Network Devices March 6, 2011 Copyright 2011 by World Class CAD, LLC. All Rights Reserved. Types of Network Devices In this lesson, we will learn about Network Interface Cards (NIC), Hubs, Switches, and

More information

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services BLACKBOX NETWORK SERVICES one source for worldwide infrastructure services 24 Port 10/100Mbps plus 2 Gigabit TX/FX Auto-MDIX Modular Gigabit Ethernet Switch User s Manual FCC Warning This device has been

More information

Data Communication. Introduction of Communication. Data Communication. Elements of Data Communication (Communication Model)

Data Communication. Introduction of Communication. Data Communication. Elements of Data Communication (Communication Model) Data Communication Introduction of Communication The need to communicate is part of man s inherent being. Since the beginning of time the human race has communicated using different techniques and methods.

More information

Chapter 1: introduction

Chapter 1: introduction Chapter 1: introduction our goal: v get feel and terminology v more depth, detail later in course v approach: use Internet as example overview: v what s the Internet? v what s a protocol? v edge; hosts,

More information

Mike Meyers Network+ Guide to Managing & Troubleshooting Networks Instructor s Manual Chapter 3

Mike Meyers Network+ Guide to Managing & Troubleshooting Networks Instructor s Manual Chapter 3 Chapter 3: Cabling and Topology Learning Objectives This chapter introduces students to the concept of network topologies, and how they apply to the physical connections as well as to the flow of signals

More information

exp-s1110pe PoE+ Gigabit Ethernet Extenders

exp-s1110pe PoE+ Gigabit Ethernet Extenders perle.com https://www.perle.com/products/10-100-1000-poe+-ethernet-extender.shtml exp-s1110pe PoE+ Gigabit Ethernet Extenders 10/100/1000 PoE+ Ethernet Copper Extenders Extends 10/100/1000Base-T up to

More information

The six major components of a structured wiring system are:

The six major components of a structured wiring system are: OBJECTIVES 1. Describe various ANSI/TIA/EIA standards for commercial buildings and residential settings. 2. Discuss the specific Technical Systems Bulletins that can affect telecommunications installations.

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information