Disjoint Layer2 Uplinks (DLU)

Size: px
Start display at page:

Download "Disjoint Layer2 Uplinks (DLU)"

Transcription

1 Disjoint Layer2 Uplinks (DLU) 1

2 Overview In UCS release 1.4, network facing interfaces are configured to support all VLANs in the system. There is no way to configure a subset of VLANs on a network facing interface. A single network-facing interface is selected to receive multicast/broadcast traffic from the upstream network. This limits UCS to deployments where the upstream networks are symmetrical (all LAN segments are reachable by each border interface). Only workaround prior to 2.x was Switch Mode Brad Hedlund explains Disjoint Layer 2 concepts and workarounds concerning 1.4 and earlier: nbucshu38 2

3 Disjoint Layer 2 Sample Topology Network Prod1 VLANs Network Dev 2 VLANs Backup Network VLAN 31 BIF2 BIF1 BIF3 BIF1 BIF2 BIF3 UCS A UCS B Assumptions There is no overlap in VLAN IDs between the disparate networks Both FI s have access to the same set of VLANs. This ensures the function of fabric failover. 3

4 Disjoint L2 Configuration Overview Define all necessary VLANs 4

5 Disjoint L2 Configuration Overview Launch LAN Uplink Manager 5

6 Disjoint L2 Configuration Overview Associate VLANs with Uplinks 6

7 Disjoint L2 Configuration Overview Verifying Configuration From UCSM CLI NXOS Context: show interface trunk Should expect to see your associated VLANs on the assigned interfaces only. Ex. Eth 1/16-17 are Uplinks Port Vlans Allowed on Trunk Eth1/16 1,5-7,1000,3000 Only Eth1/16 allows VLAN 5 Eth1/17 1,6-7,1000,3000 Veth Veth709 1,1000 <snip> 7

8 Service Profile Circuit Paths A server s virtual interface (VIF) mapping can be displayed with the show service-profile circuit command. The VIF number can be used in the NXOS level of the FI to trace a path to the upstream. UCS-B# show service-profile circuit server 1/1 Service Profile: root/esxi_3 Server: 1/1 Fabric ID: A VIF vnic Link State Overall Status Admin Pin Oper Pin Transport Unknown Unknown 0/0 0/0 Unknown 9158 Up Active 0/0 0/0 Ether 964 eth0 Up Active 0/0 0/3 Ether 966 fc0 Up Active 0/0 0/0 Fc Fabric ID: B VIF vnic Link State Overall Status Admin Pin Oper Pin Transport Unknown Unknown 0/0 0/0 Unknown 9159 Up Active 0/0 0/0 Ether 965 eth1 Up Active 0/0 0/3 Ether 967 fc1 Up Active 0/0 0/0 Fc 8

9 Active Border Interfaces The interface a VIF will use to reach the upstream network can be determined by analyzing the active border-interfaces on the FI: UCS-B(nxos)# show pinning border-interfaces active Border Interface Status SIFs Eth1/7 Active Veth729, Veth730 Eth1/8 Active Veth731 Eth1/9 Active Veth732 Eth1/16 Active Veth733 Eth1/17 Active Eth1/18 Active Eth1/19 Active Eth2/1/29 Eth1/20 Active Veth706 Eth1/21 Active Eth1/22 Active Total Interfaces : 10 FI-6248-B(nxos)# 9

10 Determining DR for Bcast & Mcast The Designated Receiver (DR) port can be determined by: UCS-B(nxos)# show platform software enm internal info vlandb [id x] all vlan_id Designated receiver: Eth1/8 Membership: Eth1/8 Eth1/9 Eth1/16 Eth1/18 Eth1/19 Eth1/20 Eth1/21 Eth1/22 Eth1/17 vlan_id Designated receiver: Eth1/16 Membership: Eth1/16 <snip> 10

11 Disjoint Layer 2 Notes Default behavior is same as pre-2.0. VLANs will be allowed on all interfaces. If no interfaces are implicitly assigned to a VLAN, then default behavior will be implemented & that VLAN will be allowed on all interfaces (traffic dynamically pinned in Round Robin fashion) In UCSM 2.0, a designated broadcast/multicast receiver is allocated on a per VLAN basis rather than on a global basis. For a downgrade, disjoint Layer 2 config should be removed as it will not be supported in versions prior to UCSM 2.0 and may cause traffic disruption. 11

12 12

Troubleshooting the Cisco UCS Compute Deployment BRKCOM Cisco and/or its affiliates. All rights reserved.

Troubleshooting the Cisco UCS Compute Deployment BRKCOM Cisco and/or its affiliates. All rights reserved. Troubleshooting the Cisco UCS Compute Deployment 2 Agenda Troubleshooting Cisco UCS Overview Physical Setup Software Setup Configuration Path Tracing Maintenance Key Takeaways Q & A 3 Overview UCS Building

More information

UCS IPv6 Management Configuration Example

UCS IPv6 Management Configuration Example UCS IPv6 Management Configuration Example Document ID: 118784 Contributed by Padmanabhan Ramaswamy and Shankar Prasath, Cisco TAC Engineers. Mar 06, 2015 Contents Introduction Prerequisites Requirements

More information

Cisco CCIE Data Center Written (Beta) Download Full Version :

Cisco CCIE Data Center Written (Beta) Download Full Version : Cisco 351-080 CCIE Data Center Written (Beta) Download Full Version : https://killexams.com/pass4sure/exam-detail/351-080 Answer: A QUESTION: 105 What is the function of the WWPN pool? A. to assign WWPNs

More information

UCS Direct Attached Storage and FC Zoning Configuration Example

UCS Direct Attached Storage and FC Zoning Configuration Example UCS Direct Attached Storage and FC Zoning Configuration Example Document ID: 116082 May 23, 2013 Contents Introduction Prerequisites Requirements Components Used Conventions Background Information UCS

More information

Understanding PVLANs in UCS

Understanding PVLANs in UCS Understanding PVLANs in UCS Introduction This document explains the PVLAN support in UCS - a feature which is introduced in the Balboa (1.4) release. This document explains the feature, the caveats and

More information

UCS Networking Deep Dive. Neehal Dass - Customer Support Engineer

UCS Networking Deep Dive. Neehal Dass - Customer Support Engineer UCS Networking Deep Dive Neehal Dass - Customer Support Engineer Agenda Chassis Connectivity Server Connectivity Fabric Forwarding M-Series Q & A Cisco Unified Computing System (UCS) Single Point of Management

More information

LAN Ports and Port Channels

LAN Ports and Port Channels Port Modes, page 2 Port Types, page 2 UCS 6300 Breakout 40 GB Ethernet Ports, page 3 Unified Ports, page 7 Changing Port Modes, page 10 Server Ports, page 16 Uplink Ethernet Ports, page 17 Appliance Ports,

More information

You can monitor or use SPAN on port channels only for ingress traffic.

You can monitor or use SPAN on port channels only for ingress traffic. This chapter includes the following sections: Traffic Monitoring, page 1 Guidelines and Recommendations for Traffic Monitoring, page 2 Creating an Ethernet Traffic Monitoring Session, page 3 Creating a

More information

UCS Networking Deep Dive

UCS Networking Deep Dive UCS Networking Deep Dive BRKCOM-2003 www.ciscolivevirtual.com Agenda Overview / System Architecture Physical Architecture Logical Architecture Switching Modes of the Fabric Interconnect Fabric Failover

More information

Fibre Channel Zoning

Fibre Channel Zoning Information About, page 1 Support for in Cisco UCS Manager, page 2 Guidelines and recommendations for Cisco UCS Manager-Based, page 4 Configuring, page 4 Creating a VSAN for, page 6 Creating a New Fibre

More information

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects? Volume: 327 Questions Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects? A. primary first, and then secondary

More information

Cisco Exam Questions & Answers

Cisco Exam Questions & Answers Cisco 642-995 Exam Questions & Answers Number: 642-995 Passing Score: 800 Time Limit: 120 min File Version: 36.9 http://www.gratisexam.com/ Exam Code: 642-995 Exam Name: Unified Computing Troubleshoot

More information

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5 Technical Marketing Solutions Guide Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5 Document Revision Date Revision Description (author) 5/16/2014 1. 0 Draft release (mmclaughlin)

More information

UCS Uplink Ethernet Connection Configuration Example

UCS Uplink Ethernet Connection Configuration Example UCS Uplink Ethernet Connection Configuration Example Document ID: 110267 Contents Introduction Prerequisites Requirements Components Used Conventions Configure Network Diagram 1. Configure Uplink Ethernet

More information

UCS Firmware Management Architecture

UCS Firmware Management Architecture UCS Firmware Management Architecture 2 Legal Disclaimer Many products and features described herein remain in varying stages of development and will be offered on a when-and-ifavailable basis. This roadmap

More information

UCS deployment guide for Nimble Storage

UCS deployment guide for Nimble Storage Summary This article is intended as a how to guide to allow for successful deployment of Nimble Storage iscsi connectivity to Cisco UCS. Nimble Storage / Cisco UCS connectivity checklist: 1) Determine

More information

Traffic Monitoring. Traffic Monitoring

Traffic Monitoring. Traffic Monitoring , page 1 Creating a Session, page 6 Editing an Existing Session, page 7 Activating or Deactivating a Session, page 7 Deleting a Session, page 8 Traffic monitoring copies traffic, from one or more source

More information

UCS Networking 201 Deep Dive

UCS Networking 201 Deep Dive UCS Networking 20 Deep Dive BRKCOM-2003 Brad Hedlund bhedlund@cisco.com Manish Tandon mtandon@cisco.com Agenda Overview / System Architecture Physical Architecture Logical Architecture Switching Modes

More information

UCS Engineering Details for the SAN Administrator

UCS Engineering Details for the SAN Administrator UCS Engineering Details for the SAN Administrator Craig Ashapa 2 First things first: debunking a myth Today (June 2012 UCS 2.02m) there is no FCoE northbound of UCS unless you really really really want

More information

Expert Reference Series of White Papers. Cisco UCS B Series Uplink Strategies

Expert Reference Series of White Papers. Cisco UCS B Series Uplink Strategies Expert Reference Series of White Papers Cisco UCS B Series Uplink Strategies 1-800-COURSES www.globalknowledge.com Cisco UCS B Series Uplink Strategies Chris Olsen, Global Knowledge Instructor, Author,

More information

UCS Networking Deep Dive

UCS Networking Deep Dive UCS Networking Deep Dive Steve McQuerry, CCIE # 6108, UCS Technical Marketing @smcquerry 2 UCS LAN Deep Dive Agenda High-level system overview review of different Fabric Interconnects, IOM and Cisco adapters

More information

Layer 2 Implementation

Layer 2 Implementation CHAPTER 3 In the Virtualized Multiservice Data Center (VMDC) 2.3 solution, the goal is to minimize the use of Spanning Tree Protocol (STP) convergence and loop detection by the use of Virtual Port Channel

More information

Cisco UCS Director Baremetal Agent Installation and Configuration Guide, Release 5.2

Cisco UCS Director Baremetal Agent Installation and Configuration Guide, Release 5.2 UCS Director Baremetal Agent Installation The purpose to this document is to illustrate the steps to install the UCS Director Baremetal Agent (PXE Server) which can be used to write/use workflows that

More information

UCS Performance Troubleshooting

UCS Performance Troubleshooting UCS Performance Troubleshooting Robert Burns, Technical Leader CCIE Data Center #37856 Housekeeping Phones on Silent Bring it in, Take it out Ask questions! 2 Agenda IInfrastructure Path Tracing LAN Performance

More information

Configuring the Fabric Interconnects

Configuring the Fabric Interconnects Configuring the Fabric Interconnects This chapter includes the following sections: Initial System Setup, page 1 Performing an Initial System Setup for a Standalone Configuration, page 3 Initial System

More information

UCS Networking Deep Dive

UCS Networking Deep Dive UCS Networking Deep Dive Sarva Chakravarthi Cisco Services UCS LAN Deep Dive - Agenda High-level System Overview Fabric Forwarding Mode of Operations Uplink Pinning Chassis / Fabric Extender Server Connectivity

More information

Overview. About the Cisco UCS S3260 System

Overview. About the Cisco UCS S3260 System About the Cisco UCS S3260 System, on page 1 How to Use This Guide, on page 3 Cisco UCS S3260 System Architectural, on page 5 Connectivity Matrix, on page 7 Deployment Options, on page 7 Management Through

More information

UCS Fabric Fundamentals

UCS Fabric Fundamentals UCS Fabric Fundamentals Hardware State Abstraction MAC Address NIC Firmware NIC Settings UUID BIOS Firmware BIOS Settings Boot Order BMC Firmware Drive Controller F/W Drive Firmware State abstracted from

More information

UCS Technical Deep Dive: Getting to the Heart of the Matter

UCS Technical Deep Dive: Getting to the Heart of the Matter UCS Technical Deep Dive: Getting to the Heart of the Matter Session ID Agenda Introductions UCS Architecture, Innovations, Topology Physical Building Blocks Logical Building Blocks Typical Use Cases (Live

More information

Introducing Cisco UCS Central 1.4

Introducing Cisco UCS Central 1.4 This chapter includes the following sections: Overview of Cisco UCS Central 1.4 Features, page 1 Behavior and Design Changes in HTML5 UI, page 10 Multi-version Management Support, page 11 Feature Support

More information

Introducing Cisco UCS Central 2.0

Introducing Cisco UCS Central 2.0 This chapter includes the following sections: Overview of Central 2.0 Features, on page 1 Behavior Changes in Release 2.0, on page 7 Multi-version Management Support, on page 8 Feature Support Matrix,

More information

Introducing Cisco UCS Central 1.3

Introducing Cisco UCS Central 1.3 This chapter includes the following sections: Overview of Cisco UCS Central 1.3 Features, page 1 Overview of Cisco UCS Central 1.3 Features Cisco UCS Central, release 1.3 allows you to take charge of the

More information

Direct Attached Storage

Direct Attached Storage , page 1 Fibre Channel Switching Mode, page 1 Configuring Fibre Channel Switching Mode, page 2 Creating a Storage VSAN, page 3 Creating a VSAN for Fibre Channel Zoning, page 4 Configuring a Fibre Channel

More information

UCS C Series Rack Servers VIC Connectivity Options

UCS C Series Rack Servers VIC Connectivity Options UCS C Series Rack Servers VIC Connectivity Options Document ID: 117637 Contributed by Shankar Prasath, Cisco TAC Engineer. Apr 25, 2014 Contents Introduction Prerequisites Requirements Components Used

More information

FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch

FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch Document ID: 117280 Contributed by Padmanabhan, Cisco TAC Engineer. Mar 25, 2014 Contents Introduction Prerequisites Requirements

More information

Cisco Actualtests Questions & Answers

Cisco Actualtests Questions & Answers Cisco Actualtests 642-999 Questions & Answers Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 22.8 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot Cisco

More information

Overview. Overview. Cisco UCS 6324 Fabric Interconnect with Cisco UCS B-Series Servers and C-Series Servers, which is. Overview 1

Overview. Overview. Cisco UCS 6324 Fabric Interconnect with Cisco UCS B-Series Servers and C-Series Servers, which is. Overview 1 This chapter includes the following sections:, on page 1 Components That Support Firmware Upgrade, on page 6 Firmware Version Terminology, on page 7 Cross-Version Firmware Support, on page 8 Server Pack,

More information

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2.

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2. UCS-ABC Why Firefly Length: 5 Days Format: Lecture/Lab Course Version: 5.0 Product Version: 2.1 This special course focuses on UCS Administration and Troubleshooting UCS Manager 2.0 and provides additional

More information

UC Voice Application Connectivity in a VMware UCS Environment

UC Voice Application Connectivity in a VMware UCS Environment UC Voice Application Connectivity in a VMware UCS Environment Contents Introduction Troubleshoot Introduction This document describes how to troubleshoot connectivity issues when Cisco Unified Communications

More information

Q&As. Troubleshooting Cisco Data Center Infrastructure. Pass Cisco Exam with 100% Guarantee

Q&As. Troubleshooting Cisco Data Center Infrastructure. Pass Cisco Exam with 100% Guarantee 300-180Q&As Troubleshooting Cisco Data Center Infrastructure Pass Cisco 300-180 Exam with 100% Guarantee Free Download Real Questions & Answers PDF and VCE file from: 100% Passing Guarantee 100% Money

More information

Vendor: Cisco. Exam Code: Exam Name: DCID Designing Cisco Data Center Infrastructure. Version: Demo

Vendor: Cisco. Exam Code: Exam Name: DCID Designing Cisco Data Center Infrastructure. Version: Demo Vendor: Cisco Exam Code: 300-160 Exam Name: DCID Designing Cisco Data Center Infrastructure Version: Demo Exam A QUESTION 1 Which three options are features of a Cisco Nexus 7700 Switch? (Choose three.)

More information

Configuring Fabric and Interfaces

Configuring Fabric and Interfaces Fabric and Interface Configuration, on page 1 Graceful Insertion and Removal (GIR) Mode, on page 2 Configuring Physical Ports in Leaf Nodes and FEX Devices Using the NX-OS CLI, on page 3 Configuring Port

More information

Configuring Adapter-FEX

Configuring Adapter-FEX The chapter contains the following sections: Adding a Server with a Server Network Adapter, page 1 Removing a Server with a Server Network Adapter, page 12 Disabling Adapter-FEX on a Switch, page 15 Adding

More information

VLANs. LAN Switching and Wireless Chapter 3. Version Cisco Systems, Inc. All rights reserved. Cisco Public 1

VLANs. LAN Switching and Wireless Chapter 3. Version Cisco Systems, Inc. All rights reserved. Cisco Public 1 VLANs LAN Switching and Wireless Chapter 3 Version 4.0 2006 Cisco Systems, Inc. All rights reserved. Cisco Public 1 Objectives Explain the role of VLANs in a converged network. Explain the role of trunking

More information

Q&As. Troubleshooting Cisco Data Center Unified Computing. Pass Cisco Exam with 100% Guarantee

Q&As. Troubleshooting Cisco Data Center Unified Computing. Pass Cisco Exam with 100% Guarantee 642-035 Q&As Troubleshooting Cisco Data Center Unified Computing Pass Cisco 642-035 Exam with 100% Guarantee Free Download Real Questions & Answers PDF and VCE file from: 100% Passing Guarantee 100% Money

More information

Global VSAN. Creating VSANs. Global VSAN, on page 1 Fibre Channel Zoning, on page 6

Global VSAN. Creating VSANs. Global VSAN, on page 1 Fibre Channel Zoning, on page 6 , on page 1 Fibre Channel Zoning, on page 6 Cisco UCS Central enables you to define global VSAN in the SAN cloud, at the domain group root, or at a domain group level. The global VSANs created in Cisco

More information

Deploying Applications in Today s Network Infrastructure

Deploying Applications in Today s Network Infrastructure Deploying Applications in Today s Network Infrastructure 2 Abstract Why did I create this Presentation? What Network engineers need to know before deploying applications Wikipedia defines virtualization

More information

Equipment Policies. Chassis/FEX Discovery Policy

Equipment Policies. Chassis/FEX Discovery Policy /FEX, page 1 Connectivity, page 6 Rack Server, page 7 Aging Time for the MAC Address Table, page 8 /FEX The chassis/fex discovery policy determines how the system reacts when you add a new chassis or FEX.

More information

UCS Fabric Fundamentals

UCS Fabric Fundamentals UCS Fabric Fundamentals Hardware State Abstraction MAC Address NIC Firmware NIC Settings UUID BIOS Firmware BIOS Settings Boot Order BMC Firmware Drive Controller F/W Drive Firmware State abstracted from

More information

UCS Networking Deep Dive

UCS Networking Deep Dive UCS Networking Deep Dive Michael Ciesla, Customer Support Engineer #clmel Agenda UCS Overview Chassis Connectivity Server Connectivity Fabric Forwarding Topologies Cisco Unified Computing System (UCS)

More information

Cisco Troubleshooting Cisco Data Center Unified Computing. Download Full Version :

Cisco Troubleshooting Cisco Data Center Unified Computing. Download Full Version : Cisco 642-035 Troubleshooting Cisco Data Center Unified Computing Download Full Version : https://killexams.com/pass4sure/exam-detail/642-035 QUESTION: 154 HOTSPOT Answer: QUESTION: 155 Which command

More information

Fabric Failover Scenarios in the Cisco Unified Computing System

Fabric Failover Scenarios in the Cisco Unified Computing System White Paper Fabric Failover Scenarios in the Cisco Unified Computing System What you will Learn Fabric failover is a feature that is unique to the Cisco Unified Computing System (UCS) and is available

More information

Traffic Monitoring and Engineering for UCS

Traffic Monitoring and Engineering for UCS Traffic Monitoring and Engineering for UCS Steve McQuerry, CCIE# 6108 Technical Marketing Engineer Agenda UCS Networking Overview Network Statistics in UCSM Understanding Collection Policies Hotspot Detection

More information

Cisco UCS Local Zoning

Cisco UCS Local Zoning Configuration Guide Cisco UCS Local Zoning Configuration Guide May 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of 30 Contents Overview...

More information

Virtualized Access Layer. Petr Grygárek

Virtualized Access Layer. Petr Grygárek Virtualized Access Layer Petr Grygárek Goals Integrate physical network with virtualized access layer switches Hypervisor vswitch Handle logical network connection of multiple (migrating) OS images hosted

More information

Cisco Exam Implementing Cisco Data Center Unified Computing Version: 9.0 [ Total Questions: 173 ]

Cisco Exam Implementing Cisco Data Center Unified Computing Version: 9.0 [ Total Questions: 173 ] s@lm@n Cisco Exam 642-999 Implementing Cisco Data Center Unified Computing Version: 9.0 [ Total Questions: 173 ] Question No : 1 HOTSPOT Answer: 2 Explanation: The fabric interconnect b changes from subordinate

More information

Virtualization Design

Virtualization Design VMM Integration with UCS-B, on page 1 VMM Integration with AVS or VDS, on page 3 VMM Domain Resolution Immediacy, on page 6 OpenStack and Cisco ACI, on page 8 VMM Integration with UCS-B About VMM Integration

More information

This document is an introduction to Unified Computing System (UCS) Mini. UCS Manager software, Release 3.0, which supports only Cisco UCS Mini

This document is an introduction to Unified Computing System (UCS) Mini. UCS Manager software, Release 3.0, which supports only Cisco UCS Mini Contents Introduction Prerequisites Requirements Configure Supported Features Unsupported Features: New Features: Configuring Unified Ports (4*10G Ports) FI Swaps a. Valid swaps b. Invalid Swaps Supported

More information

Overview. Overview. This chapter includes the following sections:

Overview. Overview. This chapter includes the following sections: This chapter includes the following sections:, page 1 Components That Support Firmware Upgrade, page 6 Firmware Version Terminology, page 7 Cross-Version Firmware Support, page 8 Server Pack, page 10 Light

More information

Overview. About the Cisco UCS S3260 System

Overview. About the Cisco UCS S3260 System About the Cisco UCS S3260 System, on page 1 How to Use This Guide, on page 3 Cisco UCS S3260 System Architectural, on page 4 Deployment Options, on page 5 Management Through Cisco UCS Manager, on page

More information

Configuring the MAC Address Table

Configuring the MAC Address Table CHAPTER 2 For information about creating interfaces, see the document, Cisco Nexus 1000V Interface Configuration Guide, Release 4.0(4)SV1(3). This chapter includes the following topics: Information About

More information

"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary

Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary Description Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary v6.0 is a five-day instructor-led course that is designed to help students prepare for the Cisco CCNP Data Center

More information

Agenda Registration & Coffee

Agenda Registration & Coffee Agenda 09.15 Registration & Coffee 09:45 Welcome & Overview - Paul D'Cruz Data Centre Systems Engineering Manager 10:00 Unified Fabric - Virtualising the Network and Storage Domain - Gordon Hirst DC CSE

More information

Connect array to Cisco UCS and VMware vsphere

Connect array to Cisco UCS and VMware vsphere Summary This article provides a step-by-step guidance to setup a Cisco UCS with a Nimble Storage iscsi array and VMware vsphere. Note: This document does not cover any boot from SAN configuration. Setup

More information

Cisco UCS Manager Network Management Guide, Release 3.2

Cisco UCS Manager Network Management Guide, Release 3.2 First Published: 2017-08-18 Last Modified: 2018-03-21 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387)

More information

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

Actual4Test.   Actual4test - actual test exam dumps-pass for IT exams Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : 642-999 Title : Implementing Cisco Data Center Unified Computing Vendor : Cisco Version : DEMO Get Latest

More information

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example Document ID: 116248 Contributed by Jim Hicks and Shelley Bhalla, Cisco TAC Engineers. May 01, 2014 Contents Introduction Prerequisites

More information

Configuring Auto-Anchor Mobility

Configuring Auto-Anchor Mobility Information About Auto-Anchor Mobility, page 1 Guest Anchor Priority, page 5 Information About Auto-Anchor Mobility You can use auto-anchor mobility (also called guest tunneling) to improve load balancing

More information

WLC 7.0 and Later: VLAN Select and Multicast Optimization Features Deployment Guide

WLC 7.0 and Later: VLAN Select and Multicast Optimization Features Deployment Guide WLC 7.0 and Later: VLAN Select and Multicast Optimization Features Deployment Guide Document ID: 112932 Contents Introduction Prerequisites Requirements Platforms Supported Conventions VLAN Select Feature

More information

Cisco UCS Manager Firmware Management Using the CLI, Release 3.1

Cisco UCS Manager Firmware Management Using the CLI, Release 3.1 First Published: 2016-01-20 Last Modified: 2017-04-27 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387)

More information

Configuring VM-FEX. Information About VM-FEX. VM-FEX Overview. VM-FEX Components. This chapter contains the following sections:

Configuring VM-FEX. Information About VM-FEX. VM-FEX Overview. VM-FEX Components. This chapter contains the following sections: This chapter contains the following sections: Information About VM-FEX, page 1 Licensing Requirements for VM-FEX, page 3 Default Settings for VM-FEX, page 3, page 4 Verifying the VM-FEX Configuration,

More information

Next Generation Data Centers Networks Consolidation and Virtualization

Next Generation Data Centers Networks Consolidation and Virtualization Next Generation Data Centers Networks Consolidation and Virtualization Samuel TAYLOR Directeur Technique Channel - WCA samtaylo@cisco.com 1 70 % of CIOs would increase spending on virtualization even if

More information

Cisco. Exam Questions DCUCI Implementing Cisco Data Center Unified Computing (DCUCI)

Cisco. Exam Questions DCUCI Implementing Cisco Data Center Unified Computing (DCUCI) Cisco Exam Questions 642-999 DCUCI Implementing Cisco Data Center Unified Computing (DCUCI) 1. Which two are true with respect to the unified ports on the Cisco Unified Computing System 62XX Fabric Interconnect?

More information

Configuring Network-Related Policies

Configuring Network-Related Policies This chapter includes the following sections: Configuring vnic Templates, page 1 Configuring Ethernet Adapter Policies, page 8 Configuring the Default vnic Behavior Policy, page 19 Configuring LAN Connectivity

More information

Reference Architecture. DataStream. UCS Direct Connect. For DataStream OS 2.6 or later Document # NA Version 1.08 April

Reference Architecture. DataStream. UCS Direct Connect. For DataStream OS 2.6 or later Document # NA Version 1.08 April DataStream For DataStream OS 2.6 or later Document # 310-0026NA Version 1.08 April 2017 www.cohodata.com Abstract This reference architecture describes how to connect DataStream switches to Cisco Unified

More information

Overview of the Cisco OpenFlow Agent

Overview of the Cisco OpenFlow Agent About OpenFlow, page 1 Information About Cisco OpenFlow Agent, page 2 About OpenFlow OpenFlow is an open standardized interface that allows a software-defined networking (SDN) controller to manage the

More information

Microsoft Network Load Balancing on UCS B Series Servers Deployment Configuration Example

Microsoft Network Load Balancing on UCS B Series Servers Deployment Configuration Example Microsoft Network Load Balancing on UCS B Series Servers Deployment Configuration Example Document ID: 118262 Contributed by Charles Stizza, Vishal Mehta, and Vincent La Bua, Cisco TAC Engineers. Aug 14,

More information

BMC BladeLogic for Cisco UCS. Tore Brynaa Business Solution Manager, BMC Software

BMC BladeLogic for Cisco UCS. Tore Brynaa Business Solution Manager, BMC Software BMC BladeLogic for Cisco UCS Tore Brynaa Business Solution Manager, BMC Software Gartner Group: Virtualizing the Data Center Sprawled Component-Orientation Virtualized Layer-Orientation Automated Service-Orientation

More information

Network Configuration Example

Network Configuration Example Network Configuration Example Configuring Private VLANs on a QFX Switch Using Extended Functionality Modified: 2016-08-01 Juniper Networks, Inc. 1133 Innovation Way Sunnyvale, California 94089 USA 408-745-2000

More information

Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group

Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group 2 UCS Bundled Upgrades Useful for Staging, Labs, and Non Productions This does a very quick fast upgrade

More information

CISCO EXAM QUESTIONS & ANSWERS

CISCO EXAM QUESTIONS & ANSWERS CISCO 642-999 EXAM QUESTIONS & ANSWERS Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 32.5 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot CISCO 642-999

More information

CCIE Data Center Lab Exam Version 1.0

CCIE Data Center Lab Exam Version 1.0 CCIE Data Center Lab Exam Version 1.0 CCIE Data Center Sky rocketing Popularity should not come as any surprise As per Cisco Global Cloud index, published in 2012, gave prediction that by 2016 nearly two

More information

Configure Cisco UCS Organization-Aware VLANs to Restrict Network Access

Configure Cisco UCS Organization-Aware VLANs to Restrict Network Access White Paper Configure Cisco UCS Organization-Aware VLANs to Restrict Network Access What You Will Learn Cisco UCS Manager Release 2.0 allows users to configure service profiles to access any upstream VLAN,

More information

UCS Management Deep Dive

UCS Management Deep Dive UCS Management Deep Dive Jeff Silberman UCS Technical Marketing Engineer 2 Agenda Introductions UCS Architecture, Innovations, Topology Physical Building Blocks Logical Building Blocks Typical Use Cases

More information

CISCO EXAM QUESTIONS & ANSWERS

CISCO EXAM QUESTIONS & ANSWERS CISCO 642-999 EXAM QUESTIONS & ANSWERS Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 32.5 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot CISCO 642-999

More information

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect Vblock Architecture Andrew Smallridge DC Technology Solutions Architect asmallri@cisco.com Vblock Design Governance It s an architecture! Requirements: Pretested Fully Integrated Ready to Go Ready to Grow

More information

interface info bond0 Interface : bond0 Interface Type : Bonding Interface Slave Interfaces : eth2, eth3 climconfig bond0 bond0 bond0 eth4: <BROADCAST,

interface info bond0 Interface : bond0 Interface Type : Bonding Interface Slave Interfaces : eth2, eth3 climconfig bond0 bond0 bond0 eth4: <BROADCAST, interface info bond0 Interface : bond0 Interface Type : Bonding Interface Slave Interfaces : eth2, eth3 climconfig bond0 bond0 bond0 eth4: state DOWN eth5: state

More information

Creating private Megaport connections using Juniper MX and EX series devices

Creating private Megaport connections using Juniper MX and EX series devices devices 1 Creating private Megaport connections using Juniper MX and EX series devices In this article, we will document, how to create a Point-to-Point connection between two end-points on Megaport Backbone.

More information

UCS Manager Configuration Best Practices (and Quick Start)

UCS Manager Configuration Best Practices (and Quick Start) UCS Manager Configuration Best Practices (and Quick Start) UCS TME White Paper by Jeff Silberman Version 0.85 What You Will Learn The UCS Manager (UCSM) presents a new paradigm for server management. Among

More information

Configuring Virtual Port Channels

Configuring Virtual Port Channels This chapter contains the following sections: Information About vpcs vpc Overview Information About vpcs, on page 1 Guidelines and Limitations for vpcs, on page 11 Verifying the vpc Configuration, on page

More information

Introduction to Cisco UCS Central

Introduction to Cisco UCS Central Introducing Cisco UCS Central, page 1 Introducing Cisco UCS Central Cisco UCS Central provides scalable management solution for growing Cisco UCS environment. Cisco UCS Central simplifies the management

More information

Deploying Secure Multi-Tenancy into Virtualized Data Centers

Deploying Secure Multi-Tenancy into Virtualized Data Centers Deploying Secure Multi-Tenancy into Virtualized Data Centers April 5, 2010 Introduction IT infrastructure today too often suffers from over segmentation of server, network, and storage resources. Each

More information

Vendor: Cisco. Exam Code: Exam Name: Designing Cisco Data Center Unified Fabric (DCUFD) Version: Demo

Vendor: Cisco. Exam Code: Exam Name: Designing Cisco Data Center Unified Fabric (DCUFD) Version: Demo Vendor: Cisco Exam Code: 642-996 Exam Name: Designing Cisco Data Center Unified Fabric (DCUFD) Version: Demo DEMO QUESTION 1 Which three Cisco technologies or solutions are used during the virtualization

More information

Configuring Flex Links

Configuring Flex Links This chapter describes how to configure flex links. It contains the following sections: Information About Flex Links, page 1 Guidelines, page 2 Default Settings, page 3, page 3 Configuring Flex Link Preemption,

More information

UCS C-Series Deployment Options, Best Practice and UCSM Integration

UCS C-Series Deployment Options, Best Practice and UCSM Integration UCS C-Series Deployment Options, Best Practice and UCSM Integration Steve McQuerry, Manager, Technical Marketing, CCIE #6108 #clmel Agenda Overview and Common Applications C-Series Integration Connectivity

More information

HPE2-Z39. Fast Track - Applying Aruba Switching Fundamentals for Mobility. Download Full version :

HPE2-Z39. Fast Track - Applying Aruba Switching Fundamentals for Mobility. Download Full version : HP HPE2-Z39 Fast Track - Applying Aruba Switching Fundamentals for Mobility Download Full version : http://killexams.com/pass4sure/exam-detail/hpe2-z39 QUESTION: 44 A switch receives a broadcast frame

More information

Cisco Nexus 1000V for VMware vsphere VDP Configuration Guide, Release 5.x

Cisco Nexus 1000V for VMware vsphere VDP Configuration Guide, Release 5.x Cisco Nexus 1000V for VMware vsphere VDP Configuration Guide, Release 5.x First Published: August 12, 2014 Last Modified: November 10, 2014 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive

More information

Service Profiles and Templates

Service Profiles and Templates Service Profile Templates, page 1 Service Profiles, page 3 Service Profile Templates Service profile templates enable you to quickly create several service profiles with the same basic parameters, such

More information

Managing Network Adapters

Managing Network Adapters Managing Network Adapters This chapter includes the following sections: Overview of the Cisco UCS C-Series Network Adapters, page 1 Viewing Network Adapter Properties, page 3 Configuring Network Adapter

More information

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections:

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections: This chapter contains the following sections: Information About FCoE NPV, page 1 FCoE NPV Model, page 3 Mapping Requirements, page 4 Port Requirements, page 5 NPV Features, page 5 vpc Topologies, page

More information