3 Downloading the Project via Serial Cable

Size: px
Start display at page:

Download "3 Downloading the Project via Serial Cable"

Transcription

1 Downloading Projects to an EXTER Operator 1 Function and Area of Use This document describes different ways to download an Information Designer project to an EXTER operator terminal, especially in comparison to download methods of a CIMREX PROG project to a CIMREX operator terminal. 2 About this Start Up Document This Start Up document should not be considered as a complete manual. It is an aid to be able to start up a normal application quickly and easily. For further information we refer to the Information Designer reference manual (MA00749C). This document and other Start Up documents can be downloaded from 3 Downloading the Project via Serial Cable With CIMREX operator terminals, the most common way to download projects is via serial cable. With EXTER operator terminals, the most efficient download method is to use the built-in Ethernet port, but serial download is also possible. 3.1 Serial Connection via the RS232 Port The RS232 port (9-pin D-sub) on the EXTER operator terminal is a standard port. On the CIMREX operator terminal, pin 2 and 3, as well as pin 7 and 8, are alternated. Because of this, CAB5, that is used to program the CIMREX operator terminals, does not work to program an EXTER operator terminal. CAB30 is recommended instead. It is also possible to combine a CAB5 and a CAB12 that crosses pin 2 and 3. RS232 CAB30 or CAB5 + CAB12 RS232 Page 1 (6) Start Up template 0610 Head Office Beijer Electronics AB Box 426 SE Malmö, Sweden Tel: Fax: Subsidiary Beijer Electronics GmbH Zettachring 2A Stuttgart, Germany Tel: Fax: Subsidiary Beijer Electronics Inc. 939 N. Plum Grove Road, Suite F Schaumburg, IL , USA Tel: Fax: Subsidiary Hitech Electronics Corp. 4F, No , Chung-Cheng Road Shin-Tien, Taipei Shien, Taiwan, R.O.C. Tel: Fax:

2 3.2 Serial Connection via the RS422 Port Downloading projects via the RS422 port works in the same way as via the RS232 port, but another cable is used. CAB6 is used to connect the EXTER operator terminals, as well as the CIMREX operator terminals, serially to a. RS232 CAB6 RS Settings in Information Designer Regardless if the RS232 or the RS422 port is used, the same settings are to be made in Information Designer. Select Transfer/Project. Click Settings. Select Use serial transfer, and then indicate which port and baud rate to be used. A baud rate up to bit/s can be selected. Click OK. Check Send complete project and then click Send to transfer the project to the operator terminal. The operator terminal automatically changes to transfer mode, and receives the project. Page 2 (6)

3 4 Downloading the Project via Ethernet The most efficient way to download the project to the EXTER operator terminal is to use the built-in Ethernet card. The operator terminal is configured with a default IP address ( ) at delivery, which can be changed if desired. The operator terminal can easily be programmed via Ethernet, by following the steps below. 4.1 Connection to the Built-in Ethernet Port To program the operator terminal via Ethernet, an Ethernet connection is needed in the, and also a hub or switch, or a crossover twisted pair cable. Hub/switch Twisted pair cable Crossover twisted pair cable If the is not equipped with a network interface card, or the card in the is configured to be connected to an office network, CAB35 can be connected instead. CAB35 is a USB to Ethernet adapter and appears as an extra network interface card in the when connected. 4.2 Settings in the Operator At delivery, the IP address of the operator terminal is displayed on the welcome page, that is appears when power is connected to the operator terminal. To change the IP address from the welcome page, press Enter on a key terminal, or touch anywhere on the display of a touch terminal. It is also possible to change the IP address from the same menu in the operator terminal, even if it already loaded with a project, by setting switch 1 at the rear side of the operator terminal and then rebooting. Select TCP/IP settings and enter the desired IP address and subnet mask. In this example the following settings are made: Parameter Setting IP address Subnet mask The first three groups of numbers in the IP address ( ) is the network address, and the last group (1) is the address of the operator terminal. Page 3 (6)

4 4.3 Settings in the For the to be able to communicate with the operator terminal it needs to use the same network address as the operator terminal, and a unique address. In this Windows XP example the following settings are made: Parameter Setting IP address Subnet mask Select Start/Control Panel/Network Connections. Right-click on the network interface card and select Properties. Select Use the following address and fill in the IP address and subnet mask. Page 4 (6)

5 4.4 Settings in Information Designer Select Transfer/Project. Click Settings and select Use TCP/IP transfer. Click OK. Check Send complete project and then click Send to transfer the project to the operator terminal. A dialog is displayed, asking to which IP address to send the project. Make sure that the IP address of the operator terminal is selected; if not, change it. Click OK. The operator terminal automatically changes to transfer mode, and receives the project. Page 5 (6)

6 5 Downloading the Project via External Memory Another possibility when downloading the project to the EXTER operator terminal is to use an external memory; a Compact Flash card or a USB memory stick. This can be convenient for example when upgrading an existing project in an establishment where no with Information Designer is available, or when bringing a is not possible. Note: The EXTER K30, EXTER T40, EXTER K60 and EXTER T60 operator terminals are not equipped with a Compact Flash memory card slot, but a USB memory stick can be used. 5.1 Loading the External Memory with the Project To be able to load the operator terminal with a project from an external memory, a transfer file has to be created to be saved on the memory. Connect the external memory to the. Open the desired Information Designer project. Select Transfer/Export Project Transfer File. Select the external memory as destination of the transfer file, and click Save. A.dat file is now created on the memory. Connect the operator terminal to power, and the connect the external memory. The memory is detected. If it is the first time to connect the external memory to an operator terminal, a dialog will be displayed, asking if a structure is to be created on the memory. Select Yes. The project is now loaded in the operator terminal. This procedure works on the operator terminal at delivery without any configuration. The function can be turned off, if desired, by selecting Setup/ Options in Information Designer, and unchecking Load project automatically on detection. Page 6 (6)

Name List in Information Designer

Name List in Information Designer Page 1 (9) PREN1111 2009-01 WHAT IS THE NAME LIST? 2 HOW TO USE THE NAME LIST 2 MAKING A NEW NAME LIST 2 MAKING A NAME LIST IN AN EXISTING PROJECT 3 IMPORT FROM CSV 4 IMPORT MODULES 5 SIEMENS STEP7 5 BECKHOFF

More information

Preface. Information Designer User s Guide. Preface

Preface. Information Designer User s Guide. Preface User s Guide Preface Information Designer User s Guide Preface Information Designer is a software application for the configuration of CIMREX and EXTER operator terminals. Information Designer helps you

More information

HMI I/O Controller. Installation Manual. English MAEN987,

HMI I/O Controller. Installation Manual. English MAEN987, MAEN987, 2009-06 HMI I/O Controller Installation Manual English Foreword HMI I/O Controller Installation Manual Foreword The H-T40m-P operator panel can be equipped with the HMI I/O Controller, an expansion

More information

Beijer Electronics Data Collector. Manual. English MAEN826D,

Beijer Electronics Data Collector. Manual. English MAEN826D, MAEN826D, 2015-11 Beijer Electronics Data Collector Manual English HEAD OFFICE SWEDEN Beijer Electronics Products AB Box 426 SE-201 24 Malmö, Sweden Tel: +46 40 35 86 00 Fax: +46 40 93 23 01 info@beijerelectronics.com

More information

Quick and easy intuitive configuration. Drivers enable full connectivity. Easy installation cables. Remote access and control.

Quick and easy intuitive configuration. Drivers enable full connectivity. Easy installation cables. Remote access and control. Quick and easy intuitive configuration Information Designer s easy-to-learn usability makes it easy to create applications that are logical and user friendly, enabling flexible and efficient interfaces

More information

EXTER INTELLIGENT DESIGN

EXTER INTELLIGENT DESIGN EXTER INTELLIGENT DESIGN As one of the world s leading suppliers of Human Machine Interface (HMI) solutions, Beijer Electronics makes a point of uniting function with form. Form has an important role to

More information

H-T80. Installation and Operation Manual. English MAEN833A

H-T80. Installation and Operation Manual. English MAEN833A H-T80 Installation and Operation Manual MAEN833A 2007-11 English Foreword H-T80 Installation and Operation Manual Foreword H-T80 is a Human Machine Interface (HMI) with a 7.5 STN Liquid Crystal Display,

More information

IFC ETTP, IFC ETCX. Manual. English MA00328C

IFC ETTP, IFC ETCX. Manual. English MA00328C MA00328C 2001-05 IFC ETTP, IFC ETCX Manual English Sweden Beijer Electronics AB Box 426 S-201 24 Malmö Telephone 46 40 35 86 00 Telefax 46 40 93 23 01 Norway Beijer Electronics AS Boks 487 N-3002 Drammen

More information

Start-Up. XAML-Import into ix Developer 2.10 KI Function and area of use. 2 About the Start-up document

Start-Up. XAML-Import into ix Developer 2.10 KI Function and area of use. 2 About the Start-up document Start-Up XAML-Import into ix Developer 2.10 KI00365 2014-09 1 Function and area of use This document explains how to import vector graphics, XAML-components, into ix Developer 2.10. WPF uses vector graphics

More information

H-T70. Installation and Operation Manual. English MAEN

H-T70. Installation and Operation Manual. English MAEN H-T70 Installation and Operation Manual MAEN922 2007-11 English Foreword H-T70 Installation and Operation Manual Foreword H-T70 is a Human Machine Interface (HMIs) with a 7 TFT Liquid Crystal Display,

More information

PWS6300S Operating Guide HITECH. Introduction

PWS6300S Operating Guide HITECH. Introduction PWS6300S Operating Guide HITECH Introduction PWS6300S is a Human Machine Interface (HMI) with a 3" STN LCD of a high resolution (160?80) and is IP65/NEMA4 proof with water and dust-resistant. The PWS6300S

More information

P W S -S E R I E S T H E R AT I O N A L C H O I C E.

P W S -S E R I E S T H E R AT I O N A L C H O I C E. P W S -S E R I E S T H E R AT I O N A L C H O I C E. The rational choice Operator terminals matching your specific needs The PWS-series offers valuable HMI functionality at an affordable level. The series

More information

NAT Proxy Server. Administrator Installation and Configuration Guide. 08NATPM.IX2.00c.en2

NAT Proxy Server. Administrator Installation and Configuration Guide. 08NATPM.IX2.00c.en2 NAT Proxy Server Administrator Installation and Configuration Guide 08NATPM.IX2.00c.en2 DSG, DSG logo, InterPBX, InterServer, Blaze Series, Savanna, VG5000, VG6000, VG7000, IP590, IP580, IP500, IP510,

More information

Installation Guide. Installation Instructions for Models: DI-148 Series DI-158 Series DI-710 Series DI-715B Series DI-718B(x) Series.

Installation Guide. Installation Instructions for Models: DI-148 Series DI-158 Series DI-710 Series DI-715B Series DI-718B(x) Series. Installation Guide Installation Instructions for Models: DI-148 Series DI-158 Series DI-710 Series DI-715B Series DI-718B(x) Series Revision G M-101030 Hardware and Software Installation Guide DI-148,

More information

Before installing this product, ensure that the following prerequisites are completed.

Before installing this product, ensure that the following prerequisites are completed. 2 Preparation 2.1 Items to Check...2-2 2.2 Connecting PC with display unit...2-6 2.3 Setting PC Network...2-7 2.4 Set the network of display unit...2-19 2-1 Items to Check 2.1 Items to Check Before installing

More information

Before installing this product, ensure that the following prerequisites are completed.

Before installing this product, ensure that the following prerequisites are completed. 2 Preparation 2.1 Items to Check...2-2 2.2 Connecting PC with display unit...2-5 2.3 Setting PC Network...2-6 2.4 Set the network of display unit...2-19 2-1 Items to Check 2.1 Items to Check Before installing

More information

SHEET. BAS Portable Router BACnet Multi-Network Router. BAS Portable Router

SHEET. BAS Portable Router BACnet Multi-Network Router. BAS Portable Router BAS Portable Router d a t a SHEET BAS Portable Router BACnet Multi-Network Router The BAS Portable Router provides stand-alone routing between BACnet networks such as BACnet/IP, BACnet Ethernet, and BACnet

More information

Application Note #5525

Application Note #5525 May-13 Application Note #5525 Connecting a DMC-30012 to a Beijer ExterT60 HMI Table of Contents Description... 1 Set-up... 2 Materials... 2 Connecting to the DMC-30012... 2 Connecting the BLM Motor...

More information

Diagnostic Utility. Quick Start Guide

Diagnostic Utility. Quick Start Guide Diagnostic Utility Quick Start Guide Contents 1. Getting started with Diagnostic Utility...1 1.1 Start the Diagnostic Utility...1 1.2 Select the PC interface connected with bar code printer...2 2. Configure

More information

Kollmorgen Visualization Builder

Kollmorgen Visualization Builder Kollmorgen Visualization Builder AKI2G-MOD-CDB ***NOT SUPPORTED*** ***NOT SUPPORTED*** AKI2G-MOD-CDA ***NOT SUPPORTED*** ***NOT SUPPORTED*** Edition A, April 2017 Keep all manuals as a product component

More information

Print Server. User s Manual. Rev. 01 (April, 2004) Made In Taiwan

Print Server. User s Manual. Rev. 01 (April, 2004) Made In Taiwan Print Server User s Manual Rev. 01 (April, 2004) Made In Taiwan TABLE OF CONTENTS ABOUT THIS GUIDE... 4 INTRODUCTION... 5 PACKAGE CONTENTS... 6 SYSTEM REQUIREMENTS... 6 GENERAL FEATURES... 7 PRODUCT VIEW...

More information

NAT Proxy Server. Administrator Installation and Configuration Guide. 06NATPM.IX1.01a.en1

NAT Proxy Server. Administrator Installation and Configuration Guide. 06NATPM.IX1.01a.en1 NAT Proxy Server Administrator Installation and Configuration Guide 06NATPM.IX1.01a.en1 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, IP580, IP500, InterClient, NAT Proxy, and S300X are trademarks

More information

In-Circuit Emulator. UNetICE for ARM

In-Circuit Emulator. UNetICE for ARM In-Circuit Emulator UNetICE for ARM User Manual Version 1.0 Rorixwell Inc. Authorized distributor by Embest Info&Tech Tel: +1 (416) 757 0764 Fax: +1 (416) 757 0764 10 Electro Road, Toronto, ON, M1R 2A7,

More information

EZ-ETHERNET APPLICATION GUIDE

EZ-ETHERNET APPLICATION GUIDE 1. Select DirectLogic Ethernet Rev D as the PLC Type and Protocol. 2. Once the information above is entered click the OK button. 3. Using a standard Category 5 Ethernet patch cable connect the panel to

More information

EEG ComCC 1250m Modem Data Multiplexer

EEG ComCC 1250m Modem Data Multiplexer EEG ComCC 1250m Modem Data Multiplexer Product Manual EEG Enterprises, Inc. 586 Main Street Farmingdale, New York 11735 TEL: (516) 293-7472 FAX: (516) 293-7417 Copyright EEG Enterprises, Inc. 2010 All

More information

Operating Instruction MEW01082 Revision -

Operating Instruction MEW01082 Revision - Operating Instruction MEW01082 Revision - OPC512 V2.5.x for Web-server II, 1598 Author: Anders Malmberg Date of issue: 2008-02-25 Date of rev: This page has deliberately been left blank. Table of contents

More information

How to Upgrade or Recover the Firmware of the UC-7400 Series Embedded Computers

How to Upgrade or Recover the Firmware of the UC-7400 Series Embedded Computers How to Upgrade or Recover the Firmware of the UC-7400 Series Embedded Computers Bruce Chen, Project Supervisor, Moxa Technical Support Dept. Moxa offers the boot loader utility for firmware upgrade or

More information

BAS Router BACnet Multi-Network Router

BAS Router BACnet Multi-Network Router BAS Router BACnet Multi-Network Router The BAS Router provides stand-alone routing between BACnet networks such as BACnet/IP, BACnet Ethernet, and BACnet MS/TP thereby allowing the system integrator to

More information

Network USB over IP Server With 1-USB2.0 Port. User Manual V1.0

Network USB over IP Server With 1-USB2.0 Port. User Manual V1.0 Network USB over IP Server With 1-USB2.0 Port User Manual V1.0 1 2 TABLE OF CONTENTS COPYRIGHT...4 1. INTRODUCTION...5 PRODUCT OVERVIEW...5 COMPONENTS AND FEATURES...5 HARDWARE INSTALLATION...5 2. THE

More information

Longshine Technologie Europe GmbH

Longshine Technologie Europe GmbH Longshine Technologie Europe GmbH www.longshine.de TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3 2. MFP SERVER INSTALLATION...5

More information

User Manual FRM301 SNMP Upgrade Procedure

User Manual FRM301 SNMP Upgrade Procedure User Manual FRM301 SNMP Upgrade Procedure FRM301 SNMP Upgrade Procedure Version 1.0 July 2005 CTC Union Technologies Co.,Ltd. 2005 All rights reserved The contents of this document are subject to change

More information

JARLTECH. ISO 9002 Certified. Lead with technology JP-8005U USB. Win customers with service. Cash Drawer Opener

JARLTECH. ISO 9002 Certified. Lead with technology JP-8005U USB. Win customers with service. Cash Drawer Opener JARLTECH ISO 9002 Certified Lead with technology Win customers with service JP-8005U USB Cash Drawer Opener Jarltech International Inc. 2003. All rights reserved. Under the copyright laws, this manual

More information

Lab IP Addresses and Network Communication

Lab IP Addresses and Network Communication Lab 3.5.2 IP Addresses and Network Communication Objectives Build a simple peer-to-peer network and verify physical connectivity. Assign various IP addresses to hosts and observe the effects on network

More information

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver www.longshine.de TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3

More information

WELCOME TO TOSIBOX EN / V.1.01.

WELCOME TO TOSIBOX EN / V.1.01. WELCOME TO TOSIBOX EN / V.1.01. 1. Why TOSIBOX?...3 2. TOSIBOX terminology...4 3. Initial setup...6 4. Additional locations...9 5. Creating Backup Key...10 6. Defining access rights for additional users...11

More information

Application Note Redundancy Configuration FG-110 FF

Application Note Redundancy Configuration FG-110 FF Application Note Redundancy FG-110 FF 1 Commissioning the Hardware... 2 1.1 Hardware Installation... 2 1.2 Adding a Second Linking Device... 3 2 Commissioning the Software... 3 2.1 Network... 3 2.2 of

More information

L2+ 16-/24-Port Gigabit PoE. + 2-/4-Port 10G SFP+ Managed Switch. with LCD Touch Screen GS P2XV(R)/GS UP2XV(R)

L2+ 16-/24-Port Gigabit PoE. + 2-/4-Port 10G SFP+ Managed Switch. with LCD Touch Screen GS P2XV(R)/GS UP2XV(R) L2+ 16-/24-Port Gigabit PoE + 2-/4-Port 10G SFP+ Managed Switch with LCD Touch Screen GS-5220-16P2XV(R)/GS-5220-16UP2XV(R) GS-5220-24P4XV(R)/GS-5220-24PL4XV(R) GS-5220-24UP4XV(R)/GS-5220-24UPL4XV(R) Quick

More information

2 Preparation. 2.1 Items to Check Connecting PC with GP Setting PC Network Setting GP Network...

2 Preparation. 2.1 Items to Check Connecting PC with GP Setting PC Network Setting GP Network... 2 Preparation 2.1 Items to Check...2-2 2.2 Connecting PC with GP...2-6 2.3 Setting PC Network...2-9 2.4 Setting GP Network...2-27 2-1 Items to Check 2.1 Items to Check Before installing this product, ensure

More information

Access Control System

Access Control System Access Control System Version 3.0 Hardware and Software Installation Guide Long Range RFID (UHF) Readers and Tags Specialist Smart Key Access Control System Installation Guide i Smart Key Contact Information

More information

MODEL: B09014-LAP- Compact Flash 4.1-M

MODEL: B09014-LAP- Compact Flash 4.1-M MODEL: B09014-LAP- Compact Flash 4.1-M PART NO: VERSION: V1.00 Approver GM PM Check Design Customer Confirm *Please fax the file to Zeroplus Technology after signing. 2F, NO.123, Jian Ba Rd, Tel:+886-2-66202225

More information

INTUITIVE Marine HMI.

INTUITIVE Marine HMI. INTUITIVE Marine HMI. Your partner for intuitive marine solutions. As a leading developer of Marine HMI technology, Beijer Electronics knows the industry inside out. We are constantly upgrading our complete

More information

Please take the time now to check the contents of your package: HPS12U Print Server One CD-ROM Quick Installation Guide One power adapter

Please take the time now to check the contents of your package: HPS12U Print Server One CD-ROM Quick Installation Guide One power adapter Congratulations on purchasing Hawking s HPS12U 1-Port Parallel + 2 USB Ports 10/100M Internet Print Server. The Hawking HPS12U is a powerful and convenient network printing solution that will connect your

More information

Portable BASrouter BACnet Multi-Network Router

Portable BASrouter BACnet Multi-Network Router Portable BASrouter BACnet Multi-Network Router The Portable BASrouter is a compact BACnet multi-network router which provides versatile standalone routing between BACnet/IP, BACnet Ethernet (ISO 8802-3),

More information

ix - FX3U-ENET(ADP) and FX3GE KI00311A

ix - FX3U-ENET(ADP) and FX3GE KI00311A 1 Function and area of use This document explains how to set up ethernet connection with FX3U-ENET/-APD or FX3GE and ix application. Software covered in this document: ix Developer 2.0 or higher FX Configurator

More information

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3 2. MFP SERVER INSTALLATION...5 PREPARATION...5 CONFIGURATION SOLUTION TABLE...5

More information

C5100 Computer Connections & Software Install Guide

C5100 Computer Connections & Software Install Guide C5100 Computer Connections & Software Install Guide Installation Checklist Network Install: Hardware...4 Connect to the Network Port...4 Network Install: Software...5 TCP/IP...5 Local Install: USB, Hardware...7

More information

RC90 Upgrade Procedures

RC90 Upgrade Procedures RC90 Upgrade Procedures EM136R2547F Table of Contents Thank you for purchasing our robot system. Before using the robot system, please read this manual thoroughly and use the product properly. Keep this

More information

Quick Start Guide. GV-Video Server. 1 Introduction. Packing List

Quick Start Guide. GV-Video Server. 1 Introduction. Packing List Introduction Quick Start Guide GV-Video Server Welcome to the GV-Video Server Quick Start Guide. In the following sections, you will learn about the basic installations and configurations of the GV-Video

More information

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Ethernet Option W8, W18 March 2012, Rev. E Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without

More information

L2+ Managed Gigabit/10 Gigabit Ethernet Switch GS-5220 Series

L2+ Managed Gigabit/10 Gigabit Ethernet Switch GS-5220 Series L2+ Managed Gigabit/10 Gigabit Ethernet Switch GS-5220 Series Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Terminal Setup... 5 4. Logon to Console... 6 5.

More information

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual HOME AUTOMATION, INC. Model 93A00-1 Serial Server User s Manual Document Number 93I00-1 Rev. A December, 2009 Introduction The 93A00-1 is a RS232/RS485 to TCP/IP converter integrated with a robust system

More information

L2+ Managed PoE Switch GS-5220 PoE Series

L2+ Managed PoE Switch GS-5220 PoE Series L2+ Managed PoE Switch GS-5220 PoE Series Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 5 3. Terminal Setup... 6 4. Logon to Console... 7 5. Configuring IP Address...

More information

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision 1.03.00 Motortronics / Phasetronics 1600 Sunshine Drive Clearwater, Florida 33765 Tel: 727-573-1819 Fax: 727-573-1803

More information

User Manual FMUX01(A) SNMP Upgrade Procedure

User Manual FMUX01(A) SNMP Upgrade Procedure User Manual FMUX01(A) SNMP Upgrade Procedure FMUX01(A) SNMP Upgrade Procedure Version 1.0 June 2004 CTC Union Technologies Co.,Ltd. 2004 All rights reserved The contents of this document are subject to

More information

Fast Ethernet Print Server 1 Parallel, 2 USB

Fast Ethernet Print Server 1 Parallel, 2 USB Fast Ethernet Print Server 1 Parallel, 2 USB User s Manual Rev. 01 (Nov, 2005) Made In Taiwan TABLE OF CONTENTS ABOUT THIS GUIDE... 4 INTRODUCTION... 5 PACKAGE CONTENTS... 6 SYSTEM REQUIREMENTS... 6 GENERAL

More information

2 Preparation. 2.1 Items to Check Connecting PC with GP Setting PC Network Setting GP Network

2 Preparation. 2.1 Items to Check Connecting PC with GP Setting PC Network Setting GP Network 2 Preparation 2.1 Items to Check...2-2 2.2 Connecting PC with GP...2-6 2.3 Setting PC Network...2-9 2.4 Setting GP Network...2-21 Pro-Server EX Reference Manual 2-1 Items to Check 2.1 Items to Check Before

More information

Transparent mode with ix Developer 2.0 KI

Transparent mode with ix Developer 2.0 KI 1 Function and area of use This document explains how too set up transparent and passthrough mode in ix Developer 2.0. This document will explain the two routing features, transparent and passthrough mode.

More information

VG5000 Analog Voice Gateway

VG5000 Analog Voice Gateway VG5000 Analog Voice Gateway Administrator Installation and Configuration Guide 08VG50M.xg2.00g.EN3 DSG, DSG logo, InterPBX, Blaze, Savanna, VG5000, VG6000, VG7000, IP590, IP580, IP500, IP510, InterConsole,

More information

Industrial 24-Port 10/100/1000Mbps Managed Gigabit. Switch (-40~75 degrees C) with 4 Shared SFP Ports IGSW-24040T. Quick Installation Guide

Industrial 24-Port 10/100/1000Mbps Managed Gigabit. Switch (-40~75 degrees C) with 4 Shared SFP Ports IGSW-24040T. Quick Installation Guide Industrial 24-Port 10/100/1000Mbps Managed Gigabit Switch (-40~75 degrees C) with 4 Shared SFP Ports IGSW-24040T Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4

More information

Industrial 2-port RS422/485 Modbus Gateway

Industrial 2-port RS422/485 Modbus Gateway 2-port RS422/485 Serial Interface Two RS422/485 ports with 5-contact terminal block Cost effective for RS422/ to Fast Ethernet 10/100BASE- TX application Supports 4-wire RS422 or 2-wire with 5-contact

More information

Chapter 1 Introduction eremote Remote Control Software Supported Models System Requirement...

Chapter 1 Introduction eremote Remote Control Software Supported Models System Requirement... Table of Contents Chapter 1 Introduction... 1-1 1.1 eremote Remote Control Software... 1-1 1.2 Supported Models... 1-1 1.3 System Requirement... 1-2 Chapter 2 Software Installation... 2-1 2.1 eremote Setup...

More information

D100 ISM Step by Step Installation Guide

D100 ISM Step by Step Installation Guide D100 ISM Step by Step Installation Guide Revision 1.00 5/15/2009 Overview The Inertial Stabilization Module for the D100 requires several connections before the unit can be operated. This guide will walk

More information

SIP Proxy Server. Administrator Installation and Configuration Guide. 06SIPXM.SY1.00a.EN1

SIP Proxy Server. Administrator Installation and Configuration Guide. 06SIPXM.SY1.00a.EN1 SIP Proxy Server Administrator Installation and Configuration Guide 06SIPXM.SY1.00a.EN1 DSG, DSG logo, InterPBX, InterServer, Blaze Series, Savanna Series, VG5000, IP580, IP500, InterClient, NAT Proxy,

More information

SIP Proxy Server. Administrator Installation and Configuration Guide. 08SIPXM.SY2.20a.EN2

SIP Proxy Server. Administrator Installation and Configuration Guide. 08SIPXM.SY2.20a.EN2 SIP Proxy Server Administrator Installation and Configuration Guide 08SIPXM.SY2.20a.EN2 DSG, DSG logo, InterPBX, InterServer, Blaze Series, Savanna, VG5000, VG6000, VG7000, IP590, IP580, IP500, IP510,

More information

Service Bulletin Rev Firmware Upgrade for ACRC100 Series

Service Bulletin Rev Firmware Upgrade for ACRC100 Series Rev. 3.1.0 Firmware Upgrade for ACRC100 Series Objective This Service Bulletin defines the procedure for upgrading the firmware for the InRow ACRC to version AOS 3.1.3 and APP 3.1.0. This upgrade is mandatory

More information

AirLive RS Security Bandwidth Management. Quick Setup Guide

AirLive RS Security Bandwidth Management. Quick Setup Guide AirLive RS-2000 Security Bandwidth Management Quick Setup Guide Important Information The AP mode s default IP address is The default Subnet Mask is The default login name is The default password is!!!!

More information

Report Generator in ix Developer 2.0 KI

Report Generator in ix Developer 2.0 KI 1 Function and area of use The report generator allows generating Excel reports based on an Microsoft Excel made report template. The generated report can be output to a printer or saved as an Excel file.

More information

USB 2.0 Print Server. User s Manual. Rev. 01 (Jan, 2004) Made In Taiwan

USB 2.0 Print Server. User s Manual. Rev. 01 (Jan, 2004) Made In Taiwan USB 2.0 Print Server User s Manual Rev. 01 (Jan, 2004) Made In Taiwan TABLE OF CONTENTS ABOUT THIS GUIDE... 4 INTRODUCTION... 5 PACKAGE CONTENTS... 6 SYSTEM REQUIREMENTS... 6 GENERAL FEATURES... 7 PRODUCT

More information

Infosystem. User Manual. Version 1.0. Serial to Ethernet Converter with 3 sockets. Infosystem Technology Corporation, Ltd.

Infosystem. User Manual. Version 1.0. Serial to Ethernet Converter with 3 sockets. Infosystem Technology Corporation, Ltd. WS-100B Serial to Ethernet Converter with 3 sockets Copyright 2005 Infosystem Technology Corporation, Ltd. No. 45, Lane 167, Dongnan St. Hsinchu, Taiwan 300, R.O.C. TEL: +886-3-562-7187 FAX: +886-3-561-1435

More information

16/24/48-Port 10/100/1000T + 2/4-Port 100/1000X SFP Managed Switch GS T2S/GS T2S/GS T4S. Quick Installation Guide

16/24/48-Port 10/100/1000T + 2/4-Port 100/1000X SFP Managed Switch GS T2S/GS T2S/GS T4S. Quick Installation Guide 16/24/48-Port 10/100/1000T + 2/4-Port 100/1000X SFP Managed Switch GS-4210-16T2S/GS-4210-24T2S/GS-4210-48T4S Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3.

More information

EEG CC1260 icap Interface Card

EEG CC1260 icap Interface Card EEG CC1260 icap Interface Card Product Manual EEG Enterprises, Inc. 586 Main Street Farmingdale, New York 11735 TEL: (516) 293-7472 FAX: (516) 293-7417 Copyright EEG Enterprises, Inc. 2018 All rights reserved.

More information

Use a hardwired Ethernet to RS232 Converter [Moxa N Port Express ]

Use a hardwired Ethernet to RS232 Converter [Moxa N Port Express ] How to XTA Electronics Ltd. The Design House Vale Business Park Worcester Road Stourport-on-Severn Worcs. DY13 9BZ. England Tel: 01299 879977 (Intl. +44 1299 879977) Fax: 01299 879969 (Intl. +44 1299 879969)

More information

16/24-Port 10/100/1000T 802.3at PoE + 2-Port 100/1000X SFP Managed Switch GS P2S GS P2S. Quick Installation Guide

16/24-Port 10/100/1000T 802.3at PoE + 2-Port 100/1000X SFP Managed Switch GS P2S GS P2S. Quick Installation Guide 16/24-Port 10/100/1000T 802.3at PoE + 2-Port 100/1000X SFP Managed Switch GS-4210-16P2S GS-4210-24P2S Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Terminal

More information

alt option esc Ctrl Internet Remote Client Local Client Computer Switching OSD

alt option esc Ctrl Internet Remote Client Local Client Computer Switching OSD 6-Port Combo IP KVM Switch Hardware U rack-mount size and desktop design Standalone machine controls up to 6 sets of computers Up to 2 levels can be cascaded and up to 256 computers can be controlled.

More information

TxA SoftControl - FnIO-S NA-9173 / NA-9473 Modbus RTU KI

TxA SoftControl - FnIO-S NA-9173 / NA-9473 Modbus RTU KI TxA SoftControl - FnIO-S NA-9173 / NA-9473 Modbus RTU KI00302 2012-11 1 Function and area of use The terminal TxA SoftControl communicates with a remote I/O (Crevis FnIO-S Serie) in a Modbus RTU (serial)

More information

Onetouch Technologies Co., Ltd. CA Drivers Manual. Windows 2000, XP, 98se, ME RS-232, USB

Onetouch Technologies Co., Ltd. CA Drivers Manual. Windows 2000, XP, 98se, ME RS-232, USB Onetouch Technologies Co., Ltd. CA Drivers Manual Windows 2000, XP, 98se, ME RS-232, USB Rev 6.20cs Copyright Onetouch Technologies Co., Ltd 2006 2008 All rights reserved. Onetouch are the exclusive trademarks

More information

L2+ Managed LCD Switch GS T2XV(R) / GS T4XV(R) Quick Installation Guide

L2+ Managed LCD Switch GS T2XV(R) / GS T4XV(R) Quick Installation Guide L2+ Managed LCD Switch GS-5220-16T2XV(R) / GS-5220-24T4XV(R) Quick Installation Guide Table of Contents 1 Package Contents... 3 2. Requirements... 4 3. Terminal Setup... 5 3.1 Logon to Console... 6 3.2

More information

Beijer BoX2 Image Manual. User s Guide. English MAEN205C,

Beijer BoX2 Image Manual. User s Guide. English MAEN205C, Beijer BoX2 Image Manual MAEN205C, 2018-05 User s Guide English Foreword User s Guide for Beijer BoX2 Image Manual Foreword The information in this document is valid for the latest versions of the devices

More information

Quick Start Guide. GV-Video Server

Quick Start Guide. GV-Video Server Quick Start Guide GV-Video Server Thank you for purchasing GV-Video Server. This guide is designed to assist the new user in getting immediate results from the GV-Video Server. For advanced information

More information

How to upgrade your NetComm NB5 ADSL2+ Modem From version x or to (current)

How to upgrade your NetComm NB5 ADSL2+ Modem From version x or to (current) How to upgrade your NetComm NB5 ADSL2+ Modem From version 38.51.x or 62.51.1 to 62.51.2-002 (current) IMPORTANT: 1. This upgrade utility works on Windows XP or Windows 2000 machines only. Contact NetComm

More information

Alcor USB To Serial Bridege Controller User Manual V2.00 Page 1 of 10

Alcor USB To Serial Bridege Controller User Manual V2.00 Page 1 of 10 0 User Manual For AU9720 USB To Serial Bridge Controller User Guide Official Release Revision 2.00 Public Aug 2008 Data Sheet Status Objective specification Preliminary specification Product specification

More information

Volume. EverAccess. Instruction Manual

Volume. EverAccess. Instruction Manual Volume 1 EverAccess Instruction Manual EA-LAN1 Network Adapter EVERFOCUS ELECTRONICS CORPORATION EA-LAN1 Instruction Guide 2004 Everfocus Electronics Corp 2445 Huntington Drive Phone 626.844.8888 Fax 626.844.8838

More information

Congratulations on purchasing Hawking s HWPS12UG 1-Port Parallel + 2 USB Ports Wireless G Print Server. The Hawking HWPS12UG is a powerful and

Congratulations on purchasing Hawking s HWPS12UG 1-Port Parallel + 2 USB Ports Wireless G Print Server. The Hawking HWPS12UG is a powerful and Congratulations on purchasing Hawking s HWPS12UG 1-Port Parallel + 2 USB Ports Wireless G Print Server. The Hawking HWPS12UG is a powerful and convenient network printing solution that will connect your

More information

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

Printing with Windows 98SE/Me (continued)

Printing with Windows 98SE/Me (continued) Printing with Windows 98SE/Me (continued) Select your DP-311P wireless print server 192.168.0.10 Click OK HP LaserJet Series II Click Apply > OK You have completed setting up your printer in Win 98SE/Me!

More information

ZigBee Server USER GUIDE

ZigBee Server USER GUIDE ZigBee Server USER GUIDE Version: 1.0 Issued Date: For Models: ZS211H / ZS212H / UBIQ520 1 Contents Chapter 1: Introduction 1 Welcome 1 Chapter 2: Installing 2 Chapter 3: Using the ZigBee Server 3 3.1

More information

G2-ES Configuration Instructions

G2-ES Configuration Instructions G2-ES Configuration Instructions This instructional support document is written for the G2-ES (Gravimetric Gateway Ethernet to Serial Converter), which in this case, is the MOXA NPort Express DE-211 Ethernet

More information

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...

More information

HMI at the speed of thought Minimize the distance between your idea and a fully deployable HMI application.

HMI at the speed of thought Minimize the distance between your idea and a fully deployable HMI application. ix HMI solution HMI at the speed of thought Minimize the distance between your idea and a fully deployable HMI application. Changing the way you develop human machine interfaces. Feature by feature. The

More information

EN7000 & Anybus Communicator EIP/MODBUS-RTU user guide 1

EN7000 & Anybus Communicator EIP/MODBUS-RTU user guide 1 EN7000 & Anybus Communicator EIP/MODBUS-RTU user guide 1 This document describes how to use the HMS Anybus Communicator (ABC) with an EN7000 to control the I/O via EtherNetIP (EIP). The ABC is a gateway

More information

Multitouch/BACnet Functional description UMG 604 / UMG 605 / UMG 508 / UMG 511

Multitouch/BACnet Functional description UMG 604 / UMG 605 / UMG 508 / UMG 511 Functional description Multitouch/BACnet UMG 604 / UMG 605 / UMG 508 / UMG 511 Doc no. 2.033.107.0 www.janitza.com BACnet activation UMG 604, Article no.: 52.16.081 BACnet activation UMG 605, Article no.:

More information

factory field upgrade

factory field upgrade CK721-A Network Controller factory field upgrade version 3.1 build 25 24-10025-75 Revision B October, 2013 Copyright 2013 Johnson Controls, Inc. All Rights Reserved No part of this document may be reproduced

More information

XPort Development Kit Quick Start Guide. XPort Quick Start Guide

XPort Development Kit Quick Start Guide. XPort Quick Start Guide XPort Development Kit Quick Start Guide XPort Quick Start Guide Part Number 900-312 Revision D January 2006 Contents Contents... 1 Introduction... 1 What s in the Box... 1 Connect the XPort Evaluation

More information

E X T E R I n t e lli g e n t d e s i g n

E X T E R I n t e lli g e n t d e s i g n EXTER - Intelligent design in HMI E X T E R I n t e lli g e n t d e s i g n Robust and elegant HMI design Combining form and function, the EXTER panel s award winning design brings high-performance together

More information

Multi-port Coax + 2-port 10/100/1000T + 2-port. 100/1000X SFP Long Reach PoE over Coaxial. Managed Switch LRP-822CS / LRP-1622CS

Multi-port Coax + 2-port 10/100/1000T + 2-port. 100/1000X SFP Long Reach PoE over Coaxial. Managed Switch LRP-822CS / LRP-1622CS Multi-port Coax + 2-port 10/100/1000T + 2-port 100/1000X SFP Long Reach PoE over Coaxial Managed Switch LRP-822CS / LRP-1622CS Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements...

More information

USB to DB25 RS232 Adapter User Manual. Features. Windows 7/ Vista / 2003 / XP / 2000 Driver Installation

USB to DB25 RS232 Adapter User Manual. Features. Windows 7/ Vista / 2003 / XP / 2000 Driver Installation 765289 USB to DB25 RS232 Adapter User Manual The USB Serial Adapter is designed to make serial port expansion quick and simple. Connecting to a USB port on your computer or USB hub, the USB Serial Adapter

More information

TRP-C34H. Ethernet to 4 RS232/422/485 Converter. User s Manual. Printed Sep Rev 1.1

TRP-C34H. Ethernet to 4 RS232/422/485 Converter. User s Manual. Printed Sep Rev 1.1 TRP-C34H Ethernet to 4 RS232/422/485 Converter User s Manual Printed Sep. 2013 Rev 1.1 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax:

More information

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

QL-580N QL-1060N. Software installation guide

QL-580N QL-1060N. Software installation guide QL-580N QL-060N Software installation guide English LB95600A Features CD-ROM Precautions Do not scratch the CD-ROM. Do not subject the CD-ROM to extremely high or extremely low temperatures. Do not put

More information

User Guide V1.1. Technology Corporation. Supported by: PSC-0A-E. June 2005 Copyright 2005 Raritan Computer, Inc.

User Guide V1.1. Technology Corporation. Supported by: PSC-0A-E. June 2005 Copyright 2005 Raritan Computer, Inc. User Guide V1.1 PSC-0A-E 255-30-6107 June 2005 Copyright 2005 Raritan Computer, Inc. Raritan Computer Inc. 400 Cottontail Lane Somerset, NJ 08873 USA Tel. 1-732-764-8886 Fax. 1-732-764-8887 E-mail: sales@raritan.com

More information