Ethernet evolution: what s new and what s next

Size: px
Start display at page:

Download "Ethernet evolution: what s new and what s next"

Transcription

1 Ethernet evolution: what s new and what s next Greg Hankins <greg.hankins@nokia.com> European Peering Forum Nokia 2016 EPF /09/19

2 I ve been giving presentations about Ethernet developments for over 10 years... Thanks for listening! Cutting edge: 24 x 10 GE switch 2 Nokia 2016

3 Ethernet evolution over 40+ years Driven by new diverse market requirements Market requirements for Ethernet are changing for different applications based on its success - Speed - Distance - Media - Cost Six new Ethernet speeds are coming to market to address these different requirements - Same amount as in the past 30 years New standards for existing speeds are also in development - Newer technology, lower cost - Automotive and industrial applications - Passive optical networks (PON) Roadmap courtesy of the Ethernet Alliance: 3 Nokia 2016

4 Recent IEEE Ethernet standards 803.3bw-2015: 100BASE-T by-2016: 25 Gb/s Ethernet 803.2bq-2016: 25/40GBASE-T 802.3bp-2016: 1000BASE-T br-2016: Interspersing Express Traffic (IET) IEEE Ethernet Working Group: 4 Nokia 2016

5 IEEE Ethernet Working Group projects There s a lot going on here... P802.3bn: EPON Protocol over Coax (EPoC) Task Force P802.3bs: 200 Gb/s and 400 Gb/s Ethernet Task Force P802.3bt: DTE Power via MDI over 4-Pair Task Force P802.3bu: 1-Pair Power over Data Lines (PoDL) Task Force P802.3bv: Gigabit Ethernet Over Plastic Optical Fiber Task Force P802.3bz: 2.5G/5GBASE-T Task Force P802.3ca: 25 Gb/s, 50 Gb/s, and 100 Gb/s Ethernet Passive Optical Networks Task Force P802.3cb: 2.5 Gb/s and 5 Gb/s Backplane and Copper Cables Task Force P802.3cc: 25 Gb/s Ethernet over Single-Mode Fiber Task Force P802.3cd: 50 Gb/s, 100 Gb/s, and 200 Gb/s Ethernet Task Force P /Cor 1: (IEEE 802.3ce) Multilane timestamping YANG Data Model(s) Study Group Mb/s Single Twisted Pair Ethernet Study Group Multi-Gig Automotive Ethernet PHY Call for Interest (for discussion at the November 2016 Plenary) IEEE Ethernet Working Group: 5 Nokia 2016

6 Higher speed Ethernet target applications Key application drivers 25 GE 25 GE 50 GE 50 GE 100 GE 100 GE 200 GE 400 GE 200 GE 50 GE 100 GE 25 GE 200 GE 50 GE 400 GE 100 GE 200 GE 25/50/100/200 GE applications Data center aggregation and core Data center access Server NICs Metro/campus core 50/100/200 GE applications Service provider aggregation and core Data center core Metro core 200/400 GE applications 25 GE 50 GE 100 GE 200 GE 25 GE 50 GE 100 GE 200 GE Service provider core Large data center core Large metro core 6 Nokia 2016

7 Agenda What s new: 2.5 GE and 5 GE (don t have time, grab for an intro) 1. What s new: 25 GE (grab for background info) What s new: 40 GE (no new development, see reference slides in back) 2. What s next: 50 GE 3. What s new: 100 GE 4. What s next: 200 GE 5. What s next: 400 GE What s new: detailed optical developments (don t have time, grab /presentations/2.3_Christian_Urricariet_AusNOG2016.pdf for an overview) 7 Nokia 2016

8 Market drivers for 25 Gb/s signaling and 25 GE Provide a connection speed faster than 10 GE that is optimized for cost, throughput and efficiency Use a single 25 Gb/s signaling lane based on existing 25 Gb/s technology that is used in other Ethernet speeds and in pluggable modules Connections to switch ASICs is limited by SerDes count and bandwidth - Single higher speed 25 Gb/s lanes maximize bandwidth and switch fabric utilization vs. 4 x 10 Gb/s lanes A single higher speed lane per physical port maximizes the number of connections per switch Initially for server to access switch connections, expanded for longer reaches SFP28 pluggable module (same size as SFP and SFP+) Image courtesy of the SFF Committee. 8 Nokia 2016

9 25 GE developments IEEE P802.3cc 25 Gb/s Ethernet over Single-Mode Fiber Task Force started in May GBASE-LR: 1 x 25 Gb/s over 10 km duplex (based on 100GBASE-LR4 with RS-FEC) - 25GBASE-ER: 1 x 25 Gb/s over 40 km duplex (based on ITU-T 4L1-9D1F ER4-lite with RS-FEC) - Optional Energy Efficient Ethernet (EEE) support (fast wake mode only) Generated Draft 1.0 for Task Force review Standard expected in October 2017 Interfaces expected on the market in Task Force web page 9 Nokia 2016

10 25 GE technology reference Physical layer reach 1 m backplane 3 m copper cable 5 m copper cable 30 m twisted-pair 70 m OM3 / 100 m OM4 10 km 40 km Name 25GBASE-KR-S 25GBASE-KR 25GBASE-CR-S 25GBASE-CR 25GBASE-T 25GBASE-SR 25GBASE-LR 25GBASE-LR Standard June 2016 IEEE 802.3by June 2016 IEEE 802.3by June 2016 IEEE 802.3by June 2016 IEEE 802.3bq June 2016 IEEE 802.3by October 2017 IEEE 802.3cc October 2017 IEEE 802.3cc Electrical signaling (Gb/s) 1 x 25 1 x 25 1 x 25 1 x 25 1 x 25 1 x 25 1 x 25 Media signaling (Gb/s) 1 x 25 1 x 25 1 x 25 1 x 25 1 x nm λ 1 x nm λ 1 x nm λ Media type Backplane Twinax copper Twinax copper Cat 8 Duplex MMF Duplex Duplex Module type Market availability Backplane SFP28 SFP28 RJ45 SFP28 SFP28 SFP Nokia 2016

11 25 GE details IEEE Std 802.3bq GBASE-T: 1 x 25 Gb/s over 30 m Cat 8 4-pair twisted-pair copper cabling (ISO/IEC JTC1 SC25 WG3 and TIA TR-42.7) Optional Energy Efficient Ethernet (EEE) support 11 Nokia 2016

12 25 GE details IEEE Std 802.3by GBASE-KR-S: 1 x 25 Gb/s over 1 m Megtron 6 backplane (no FEC, BASE-R FEC) 25GBASE-KR: 1 x 25 Gb/s over 1 m Megtron 6 backplane (no FEC, BASE-R FEC, RS-FEC) 25GBASE-CR-S: 1 x 25 Gb/s over 3 m copper twinax cable (no FEC, BASE-R FEC, RS-FEC) 25GBASE-CR: 1 x 25 Gb/s over 5 m copper twinax cable (RS-FEC) 25GBASE-SR: 1 x 25 Gb/s over 70 m OM3 and 100 m OM4 duplex MMF Auto-negotiation between copper interface types and FECs Passive direct attach cable (DAC) types - CA-N (2 m; no FEC, BASE-R FEC, RS-FEC) - CA-S (3 m; no FEC, BASE-R FEC, RS-FEC) - CA-L (5 m; RS-FEC) Optional Energy Efficient Ethernet (EEE) support Forward Error Correction (FEC) Added latency* (ns) Bit Error Rate (BER) None BASE-R (Clause 74) *The latency added by FEC is insignificant for links > 500 m. 12 Nokia 2016 RS (Clause 91)

13 Agenda 1. What s new: 25 GE 2. What s next: 50 GE 3. What s new: 100 GE 4. What s next: 200 GE 5. What s next: 400 GE 13 Nokia 2016

14 Market drivers for 50 Gb/s signaling and 50 GE A faster base signaling rate is needed to for higher capacities - Rack sizes, rack units and front panels on devices must stay the same size - This means we have to go faster to support higher capacity networks Similar to 25 GE, 50 GE extends existing common network topologies for higher speeds - Reuses existing leaf/spine network architectures - Reuses existing 1 x up / 4 x down architecture The server and data center market requirements vary widely - Variety of CPU architectures, clock speeds, number of cores, and CPUs per system - Different applications have different IO and compute power requirements - Need a variety of low and high speed options to meet bandwidth requirements CFI: 14 Nokia 2016

15 50 Gb/s maximizes bandwidth and efficiency ToR switch ASICs are designed to support 128 I/O lanes Connections to switch ASICs is limited by SerDes count and bandwidth Single higher speed 50 Gb/s lanes maximize bandwidth and switch fabric utilization A single lane per physical port maximizes utilization and total interconnect bandwidth Port speed (GE) Lane speed (Gb/s) Lanes / port Usable ports lane switch capacities Total capacity (Tb/s) Now Future Source: 15 Nokia 2016

16 50 GE pluggable modules Higher speeds in common sizes New 50 GE pluggable modules in same common form factor sizes SFP56 - Extension of SFF x 50 Gb/s for 1 x 50 GE QSFP56 - Extension of SFF x 50 Gb/s for 4 x 50 GE breakout - 4 x 50 Gb/s for 1 x 200 GE Enables common higher speed port density combinations : 32 x QSFP+ ports support 4 x 10 GE down and 40 GE up : 32 x QSFP28 ports support 4 x 25 GE down and 100 GE up : 32 x QSFP56 ports support 4 x 50 GE down and 200 GE up Images courtesy of the SFF Committee. 16 Nokia 2016 SFP56 pluggable module (same size as SFP, SFP+, SFP28) QSFP56 pluggable module (same size as QSFP, QSFP+, QSFP28)

17 50 GE developments IEEE P802.3cd 50 Gb/s, 100 Gb/s, and 200 Gb/s Ethernet Task Force started in May GBASE-KR: 1 x 50 Gb/s over 1 m Megtron 6 backplane - 50GBASE-CR: 1 x 50 Gb/s over 3 m copper twinax cable - 50GBASE-SR: 1 x 50 Gb/s over 70 m OM3 and 100 m OM4 duplex MMF - 50GBASE-FR: 1 x 50 Gb/s over 2 km duplex - 50GBASE-LR: 1 x 50 Gb/s over 10 km duplex - Optional Energy Efficient Ethernet (EEE) Standard expected in September 2018 Interfaces expected on the market in Task Force web page 17 Nokia 2016

18 50 GE technology reference Physical layer reach 1 m backplane 1 m backplane 5 m copper cable 5 m copper cable 70 m OM3 / 100 m OM4 2 km 10 km Name 50GBASE-KR 50GBASE-KR2 50GBASE-CR 50GBASE-CR2 50GBASE-SR 50GBASE-FR 50GBASE-LR Standard September 2018 IEEE 802.3cd September G Ethernet Consortium September 2018 IEEE 802.3cd September G Ethernet Consortium September 2018 IEEE 802.3cd September 2018 IEEE 802.3cd September 2018 IEEE 802.3cd Electrical signaling (Gb/s) 1 x 50 2 x 25 1 x 50 2 x 25 1 x 50 1 x 50 1 x 50 Media signaling (Gb/s) 1 x 50 2 x 25 1 x 50 2 x 25 1 x nm λ 1 x nm λ 1 x nm λ Media type Backplane Backplane Twinax copper Twinax copper Duplex MMF Duplex Duplex Module type Backplane Backplane SFP56, QSFP56 TBD SFP56, QSFP56 SFP56, QSFP56 SFP56, QSFP56 Market availability TBD TBD Nokia 2016

19 Agenda 1. What s new: 25 GE 2. What s next: 50 GE 3. What s new: 100 GE 4. What s next: 200 GE 5. What s next: 400 GE 19 Nokia 2016

20 Chasm 100 GE technology adoption lifecycle 2 nd generation 100 GE crossed the chasm 1M 100 GE ports projected in 2016 by Dell Oro 802.3cd 100 GE at 2 x 50 Gb/s 3.2 Tb/s 6.4 Tb/s Innovators Early adopters Early majority Late majority Laggards premium ports/slot CXP and CFP high cost ports/slot CFP lower cost ports/slot QSFP28 and CFP4 OSFP High density low cost ports OSFP and microqsfp 1 st generation 2 nd generation 3 rd generation High density commodity ports Future SFP112 and QSFP112 Pluggable module images courtesy of Finisar. microqsfp image courtesy of the microqsfp MSA. 20 Nokia 2016

21 100 GE pluggable module evolution Graphical view of module form factors XFP (10 GE) CFP4 CFP2 CFP CFP vs. iphone 6 CFP2 vs. iphone 6 CFP4 vs. iphone 6 XFP(10 GE) CFP4 CFP2 CFP CFP2 CFP4 QSFP28* CFP images courtesy of the CFP MSA. QSFP28 image courtesy of the SFF Committee. *Not quite to scale. 21 Nokia 2016 CFP

22 100 GE pluggable module evolution microqsfp Designed for high density, shorter reach and lower power requirements - Provides QSFP functionality in an SFP-sized form factor supporting up to >3.5 W - Can support DAC, MMF and cabling Features four electrical channels - 25 Gb/s data rates support 100 GE or 4 x 25 GE breakout - Expected to support 50 Gb/s data rates Maximum 1 RU densities of - 48 ports (4.8 Tb/s) - 72 ports in 3 rows (7.2 Tb/s) Increase in port density of - 4 x SFP x QSFP Images courtesy of the microqsfp MSA. 22 Nokia 2016

23 100 GE developments IEEE P802.3cd 50 Gb/s, 100 Gb/s, and 200 Gb/s Ethernet Task Force started in May GBASE-KR2: 2 x 50 Gb/s over 1 m Megtron 6 backplane - 100GBASE-CR2: 2 x 50 Gb/s over 3 m copper twinax cable - 100GBASE-SR2: 2 x 50 Gb/s over 70 m OM3, 100 m OM4 and 150 m WBMMF duplex MMF - 100GBASE-DR2: 2 x 50 Gb/s over 500 m parallel (TBD) - 100GBASE-FR2: 2 x 50 Gb/s over 2 km duplex (TBD) - Optional Energy Efficient Ethernet (EEE) Standard expected in September 2018 Interfaces expected on the market in Task Force web page 23 Nokia 2016

24 100 GE IEEE technology reference Physical layer reach 1 m backplane 1 m backplane 3 m copper cable 5 m copper cable 7 m copper cable 70 m OM3 / 100 m OM4 70 m OM3 / 100 m OM4 / 150 m WBMMF 100 m OM3 / 150 m OM4 500 m 2 m 10 km 40 km Name 100GBASE- KP4 100GBASE- KR4 100GBASE- KR2 100GBASE- CR2 100GBASE- CR4 100GBASE- CR10 100GBASE- SR4 100GBASE- SR2 100GBASE- SR10 100GBASE- DR2 100GBASE- DF2 100GBASE- LR4 100GBASE- ER4* Standard June 2014 IEEE 802.3bj Sep 2018 IEEE 802.3cd Sep 2018 IEEE 802.3cd June 2014 IEEE 802.3bj June 2010 IEEE 802.3ba Feb 2015 IEEE 802.3bm Sep 2018 IEEE 802.3cd June 2010 IEEE 802.3ba Sep 2018 IEEE 802.3cd Sep 2018 IEEE 802.3cd June 2010 IEEE 802.3ba June 2010 IEEE 802.3ba Electrical signaling (Gb/s) 4 x 25 2 x 50 2 x 50 4 x x 10 4 x 25 2 x x 10 2 x 50 2 x x x 10 Media signaling (Gb/s) 4 x 25 NRZ or PAM-4 2 x 50 2 x 50 4 x x 10 4 x nm λs 2 x nm λ 900 nm λ 10 x nm λs 2 x 50 2 x 50 4 x nm λs 4 x nm λs Media type Backplane Backplane Twinax Twinax Twinax Parallel MMF (MPO12) Duplex MMF Parallel MMF (MPO24) Parallel (MPO12) Duplex Duplex Duplex Module type Backplane Backplane QSFP28 CFP2, CFP4, QSFP28 CXP, CFP2, CFP4, QSFP28 CFP2, CFP4, CPAK, QSFP28 QSFP28 CFP, CFP2, CFP4, CPAK, CXP, QSFP28 QSFP28 QSFP28 CFP, CFP2, CFP4, CPAK, QSFP28 CFP, CFP2 Market availability None known *100GBASE-ER4-lite (ITU-T application code 4L1-9D1F) has different optical specifications and uses the RS-FEC. 24 Nokia 2016

25 100 GE MSA technology reference Physical layer reach 70 m OM3 / 100 m OM4 500 m 2 km 2 km 2 km 2 km 10 km 40 km Name SWDM4 PSM4 10x10-2km CWDM4 CLR4 OpenOptics 10x10-10km 10x10-40km Standard Future SWDM4 Alliance September G PSM4 MSA March x10 MSA November 2015 CWDM4 MSA Group March G CLR4 Alliance March 2014 OpenOptics MSA August x10 MSA August x10 MSA Electrical signaling (Gb/s) 4 x 25 4 x x 10 4 x 25 4 x 25 4 x x x 10 Media signaling (Gb/s) 4 x nm λs 4 x nm λs 10 x nm λs 4 x nm λs 4 x nm λs 4 x nm λs 10 x nm λs 10 x nm λs Media type Duplex MMF Parallel (MPO12) Duplex Duplex Duplex Duplex Duplex Duplex Module type QSFP28 CFP4, QSFP28 CFP CFP2, CFP4, QSFP28 QSFP28 QSFP28 CFP CFP Market availability TBD TBD Non-IEEE media signaling standards that comply to the IEEE electrical signaling interface. MSA means Multisource Agreement. 25 Nokia 2016

26 Agenda 1. What s new: 25 GE 2. What s next: 50 GE 3. What s new: 100 GE 4. What s next: 200 GE 5. What s next: 400 GE 26 Nokia 2016

27 Market drivers for 200 GE Similar to 25 GE and 50 GE, 200 GE extends existing common network topologies for higher speeds - Reuses existing leaf/spine network architectures - Reuses industry investment in 50 Gb/s technology - Reuses existing 1 x up / 4 x down architecture Network backbone links need to scale to higher, cost effective speeds to match growing server speeds at the edge - Servers migrating from 10 GE to 25 GE, 40 GE and 50 GE Investment in MMF cabling infrastructure can support 40 GE to 100 GE to 200 GE capacity upgrades - Same {40,100, 200}GBASE-SR4 technologies with MPO12 connector - 4 x 850 nm λs TX, 4 x 850 nm λs RX CFI: 27 Nokia 2016

28 200 GE maximizes aggregation bandwidth Total capacity (Tb/s) 100 GE ports, 25 Gb/s lanes 200 GE ports, 50 Gb/s lanes 400 GE ports, 50 Gb/s lanes Less than current port densities Greater than current port densities ToR switch port densities Current leaf/spine network architectures are designed around 32 x 100 GE ToR switches 200 GE interfaces in a leaf/spine switch provide higher port density at a lower ASIC bandwidth than 400 GE Source: 28 Nokia 2016

29 200 and 400 GE pluggable module evolution QSFP-DD (Quad Small Form-factor Pluggable - Double Density) Designed for high speed and high density requirements Slightly deeper form factor than QSFP28 supporting >7 W (target up to 10 W) - Backwards compatible with QSFP28 - Can support DAC, MMF and cabling Features eight electrical channels - 25 Gb/s and 50 Gb/s data rates - Supports 200 GE and 400 GE - 1 x or 4 x breakout Maximum 1 RU density of 36 x QSFP-DD (14.4 Tb/s) 2 x 1 stacked integrated cage and connector QSFP-DD QSFP28 Images courtesy of the QSFP-DD MSA. 29 Nokia 2016

30 200 GE developments Copper and fiber optic cables IEEE P802.3cd 50 Gb/s, 100 Gb/s, and 200 Gb/s Ethernet Task Force started in May GBASE-KR4: 4 x 50 Gb/s over 1 m Megtron 6 backplane - 200GBASE-CR4: 4 x 50 Gb/s over 3 m copper twinax cable - 200GBASE-SR4: 4 x 50 Gb/s over 70 m OM3 and 100 m OM4 parallel MMF - Optional Energy Efficient Ethernet (EEE) Working towards Draft 1.0 Standard expected in September 2018 Interfaces expected on the market in Task Force web page 30 Nokia 2016

31 200 GE developments Fiber optic cables IEEE P802.3bs 400 Gb/s Ethernet Task Force adopted 200 GE objectives in May 2016, and became the IEEE P802.3bs 200 Gb/s and 400 Gb/s Ethernet Task Force - 200GBASE-DR4: 4 x 50 Gb/s over 500 m parallel - 200GBASE-FR4: 4 x 50 Gb/s over 2 km duplex - 200GBASE-LR4: 4 x 50 Gb/s over 10 km duplex - Optional Energy Efficient Ethernet (EEE) Generated Draft 1.5 for Task Force review Standard expected in December 2017 (no change in standard schedule due to 200 GE) Interfaces expected on the market in Task Force web page 31 Nokia 2016

32 200 GE technology reference Physical layer reach 1 m backplane 3 m copper cable 70 m OM3 / 100 m OM4 500 m 2 km 10 km Name 200GBASE-KR4 200GBASE-CR4 200GBASE-SR4 200GBASE-DR4 200GBASE-FR4 200GBASE-LR4 Standard September 2018 IEEE 802.3cd September 2018 IEEE 802.3cd September 2018 IEEE 802.3cd December 2017 IEEE 802.3bs December 2017 IEEE 802.3bs December 2017 IEEE 802.3bs Electrical signaling (Gb/s) 4 x 50 4 x 50 8 x 25 4 x 50 8 x 25 4 x 50 8 x 25 4 x 50 8 x 25 4 x 50 8 x 25 Media signaling (Gb/s) 4 x 50 4 x 50 4 x nm λs 4 x nm λs 4 x nm λs 4x nm λs Media type Backplane Twinax Parallel MMF (MPO12) Parallel (MPO12) Duplex Duplex Module type Backplane QSFP56, QSFP-DD QSFP56, QSFP-DD QSFP56, QSFP-DD QSFP56, QSFP-DD QSFP56, QSFP-DD Market availability Nokia 2016

33 Agenda 1. What s new: 25 GE 2. What s next: 50 GE 3. What s new: 100 GE 4. What s next: 200 GE 5. What s next: 400 GE 33 Nokia 2016

34 400 GE developments IEEE P802.3bs 400 Gb/s Ethernet Task Force started in March 2014 Adopted 200 GE objectives in May 2016, and became the IEEE P802.3bs 200 Gb/s and 400 Gb/s Ethernet Task Force - 400GBASE-SR16: 16 x 25 Gb/s over 70 m OM3, 100 m OM4 and 150 m WBMMF (TBD) parallel MMF - 400GBASE-DR4: 4 x 100 Gb/s over 500 m parallel - 400GBASE-FR8: 8 x 50 Gb/s over 2 km duplex - 400GBASE-LR8: 8 x 50 Gb/s over 10 km duplex - Electrical interfaces: 25 Gb/s (NRZ) and 50 Gb/s (PAM-4) - Optional Energy Efficient Ethernet (EEE) Generated Draft 1.5 for Task Force review Standard expected in December 2017 (no change in standard schedule due to 200 GE) First interfaces expected to be available in Task Force web page 34 Nokia 2016

35 400 GE pluggable module evolution estimates Each module increases density, while reducing cost and power Electrical signaling (Gb/s) 1 st generation 2 nd generation 3 rd generation 16 x 25 8 x 50 8 x 50 4 x 100 Ethernet at terabit speeds becomes feasible Module type CFP8 (~CFP2 size) CFP16 (~CFP4 size), OSFP, QSFP-DD CFP16, Future QSFP112 Market availability estimate CFP8 image courtesy Finisar. 35 Nokia 2016

36 400 GE technology reference Physical layer reach 70 m OM3 / 100 m OM4/WBMMF 500 m 2 km 10 km Name 400GBASE-SR16 400GBASE-DR4 400GBASE-FR8 400GBASE-LR8 Standard December 2017 IEEE 802.3bs December 2017 IEEE 802.3bs December 2017 IEEE 802.3bs December 2017 IEEE 802.3bs Electrical signaling (Gb/s) 16 x 25 8 x x 25 8 x x 25 8 x x 25 8 x 50 Media signaling (Gb/s) 16 x nm λs 4 x nm λs 8 x nm λs 8 x nm λs Media type Parallel MMF (MPO32) Parallel (MPO12) Duplex Duplex Module type CFP8, OSFP, QSFP-DD CFP8, OSFP, QSFP-DD CFP8, OSFP, QSFP-DD CFP8, OSFP, QSFP-DD Market availability Nokia 2016

37 Ethernet evolution futures Ethernet continues to evolve to meet new and diverse market requirements Different new speeds are needed for different new applications Old 10 x performance for 3 x cost model doesn t work anymore as we get to higher speeds - 10 ME 100 ME 1 GE 10 GE 100 GE Current best technical and economic solutions are multiples of the highest lane rate - 2 x 50 Gb/s for 100 GE - 4 x 50 Gb/s for 200 GE - 8 x 50 Gb/s for 400 GE New technology based on 50 Gb/s is the basis of a new generation of speeds 37 Nokia 2016

38 Ethernet evolution summary 2.5 GE and 5 GE is coming soon for higher speed Cat 5e/6 applications 10 GE is widely deployed in every part of the network 25 GE is available now for server and ToR aggregation 40 GE is widely deployed in data center networks 50 GE is in development for server and ToR aggregation 100 GE has transitioned to 2nd generation technology with CFP2, CFP4 and QSFP28 - New interfaces based on 25 Gb/s and 50 Gb/s signaling - New OSFP and microqsfp pluggable modules Gb/s serial signaling for longer reaches is still a challenge 200 GE is in development for server and ToR aggregation - New QSFP-DD pluggable modules 400 GE is in development for core networks Ethernet at Terabit speeds is still unfeasible in the near future, but we ll get there eventually (2020+) 38 Nokia 2016

39 References IEEE P802.3cc 25 Gb/s Ethernet over Single-Mode Fiber Task Force - IEEE P802.3cd 50 Gb/s, 100 Gb/s, and 200 Gb/s Ethernet Task Force - IEEE P802.3bs 200 Gb/s and 400 Gb/s Ethernet Task Force - CDFP MSA - CFP MSA - COBO - microqsfp MSA - QSFP-DD MSA - SFF Committee Nokia 2016

40 Questions? Acknowledgements: Scott Kipp, Brocade Samuel Liu, Nokia Steve Trowbridge, Nokia Christian Urricariet, Finisar Some older and reference slides are next Nokia 2016

41

42 MPO cable assemblies High density parallel fiber cabling 40 GE and 100 GE short reach pluggable modules use a Multifiber Push-On (MPO) cable assembly to interconnect network devices - Also called MTP by US Conec Widely available in a variety of high density multimode fiber (MMF) and single-mode fiber () cabling options for data centers - MPO to MPO - MPO cassette for patch panels with into LC, SC, etc - Keyed connectors maintain correct transmit/receive orientation 40GBASE-SR4 uses a 12-fiber OM3 or OM4 MMF MPO12 cable - 8 fibers used, left 4 for transmit and right 4 for receive - 4 middle fibers are unused 100GBASE-SR10 uses a 24-fiber OM3 or OM4 MMF MPO24 cable - 20 fibers used, top middle 10 for receive and bottom middle 10 for transmit - 2 fibers on each end are unused MPO12 connector 10 x receive 10 x transmit 100GBASE-SR10 CXP 42 Nokia 2016

43 40 GE transmission Multimode and single-mode fiber Multimode ribbon fiber - Used for distances of 100 m on OM3 and 150 m on OM4 MMF - Data is sent using multiple 850 nm lasers transmitting over multiple parallel fibers - MPO cables provide multiple separate transmit and receive strands of multimode fiber in a ribbon cable assembly Single-mode duplex fiber - Used for distances of 2 km, 10 km and 40 km on standard duplex - WDM component in the pluggable module multiplexes four transmit λs over one strand of fiber and four receive λs over the other strand of fiber in the 1310 nm CWDM band for 40GBASE-LR4 and 40GBASE-ER4-40 Gb/s serial transmit over one strand of fiber and receive over the other strand of fiber on one 1550 nm λ is used for 40GBASE-FR 4 x 10 Gb/s over parallel MMF 40GBASE-SR4 4 x 10 Gb/s over duplex 40GBASE-LR4 and 40GBASE-ER4 43 Nokia 2016

44 100 GE transmission Multimode and single-mode fiber Multimode ribbon fiber - Used for distances of 100 m on OM3 and 150 m on OM4 MMF - Data is sent using multiple 850 nm lasers transmitting over multiple parallel fibers - MPO cables provide multiple separate transmit and receive strands of multimode fiber in a ribbon cable assembly Single-mode duplex fiber - Used for distances of 2 km, 10 km and 40 km on standard duplex - WDM component in the pluggable module multiplexes all transmit λs over one strand of fiber and all receive λs over the other strand of fiber 10x10 MSA standards use 10 x 10 Gb/s λs in the 1550 nm DWDM band IEEE standards use 4 x 25 Gb/s λs in the 1310 nm CWDM band 10 x 10 Gb/s over parallel MMF 100GBASE-SR10 10 x 10 Gb/s over duplex 10x10-2km, 10x10-10km and 10x10-40km 4 x 25 Gb/s over duplex 100GBASE-LR4 and 100GBASE-ER4 44 Nokia 2016

45 40 Gb/s QSFP+ modules overview Quad Small Form-factor Pluggable+ Created for high density interfaces primarily short reach interfaces for data center applications - Small compact form factor enables low power consumption and high density - Also used for longer reach 40 GE Used for a variety of Ethernet, Fibre Channel and InfiniBand applications - 40 GE uses 4 x 10 Gb/s bidirectional channels Supports a variety of copper and fiber 40 GE interfaces - Breakout from 40 GE to 4 x 10 GE Same faceplate size as an XFP but slightly shorter 40GBASE-SR4 40GBASE-LR4 Images courtesy of Finisar. 45 Nokia 2016

46 40 GE QSFP+ pluggable modules Data center server and access: native 40 GE and 4 x 10 GE breakout Aggregation and core: native 40 GE Physical layer reach 10 m passive copper cable 100 m OM3/OM4 7 m passive copper cable 100 m OM3/ 150 m OM4 10 km 40 km Pluggable module 10GSFP+Cu 10GBASE-SR 40GBASE-CR4 40GBASE-SR4 40GBASE-LR4 40GBASE-ER4 Media Integrated twinax (QSFP+ to 4 x SFP+) Parallel MMF (MPO to 4 x Duplex LC) Integrated twinax (QSFP+ to QSFP+) Parallel MMF (MPO12) Duplex (LC) Duplex (LC) Standard July 2009 SFF-8431 June 2002 IEEE 802.3ae June 2010 IEEE 802.3ba June 2010 IEEE 802.3ba June 2010 IEEE 802.3ba February 2015 IEEE 802.3bm 40GBASE-SR4, 40GBASE-LR4, and 40GBASE-ER4 QSFP+ images courtesy of Finisar. 46 Nokia 2016

47 40 GE technology reference Physical layer reach 1 m backplane 7 m copper cable 30 m twisted-pair 100 m OM3 / 150 m OM4 2 km 10 km 40 km Name 40GBASE-KR4 40GBASE-CR4 40GBASE-T 40GBASE-SR4 40GBASE-FR 40GBASE- LR4 40GBASE-ER4 Standard June 2010 IEEE 802.3ba June 2010 IEEE 802.3ba June 2016 IEEE 802.3bq June 2010 IEEE 802.3ba March 2011 IEEE 802.3bg June 2010 IEEE 802.3ba February 2015 IEEE 802.3bm Electrical signaling (Gb/s) 4 x 10 4 x 10 4 x 10 4 x 10 4 x 10 4 x 10 4 x 10 Media signaling (Gb/s) 4 x 10 4 x 10 4 x 10 4 x nm λs 1 x nm λ (RX) 1550 nm λs (TX, RX) 4 x nm λs 4 x nm λs Media type Backplane Twinax Cat 8 Parallel MMF (MPO12) Duplex Duplex Duplex Module type Backplane QSFP+ RJ45 CFP, QSFP+ CFP CFP, QSFP+ QSFP+ Market availability None known CFP 2010 QSFP Note: there are a few 40 GE MSA standards that are not shown. 47 Nokia 2016

48 1 st generation 100 GE limitations Fundamental 1st generation technology constraints limit higher 100 GE density and lower cost Electrical signaling to the CFP Gb/s Attachment Unit Interface (CAUI) uses 10 x 10 Gb/s lanes (CAUI-10) Optical signaling on the media - 100GBASE-SR10: 10 x 10 Gb/s parallel - 10x10 MSA: 10 x 10 Gb/s λs - 100GBASE-LR4 and 100GBASE-ER4: 4 x 25 Gb/s λs CFP module size, complexity and power consumption 2nd generation modules based on 4 x 25 Gb/s electrical signaling are available now Image courtesy of Finisar. 48 Nokia cm GE Electrical signaling Optical signaling

49 1 st generation vs 2 nd generation 100 GE signaling 1 st generation 100 GE 10 x 10 Gb/s electrical and 4 x 25 Gb/s optical 2 nd generation 100 GE 4 x 25 Gb/s electrical and optical Diagram source: 49 Nokia Gb/s electrical signaling and 10:4 gearbox adds complexity, cost, space, and consumes power

50 CFP comparison Images courtesy of the CFP MSA. 50 Nokia 2016

100 GBE - WHAT'S NEW AND WHAT'S NEXT

100 GBE - WHAT'S NEW AND WHAT'S NEXT Here is more rough stuff on the ALTO ALOHA network. Memo sent by Bob Metcalfe on May 22, 1973. 100 GBE - WHAT'S NEW AND WHAT'S NEXT Greg Hankins UKNOF25 UKNOF25 2013/04/18 40 Gigabit

More information

Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications

Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications Optical Trends in the Data Center Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications Telecom 2017 Corning Restricted Incorporated 2 Server Access Switch

More information

New Data Center and Transport Interconnect Technology

New Data Center and Transport Interconnect Technology New Data Center and Transport Interconnect Technology Tom McDermott Fujitsu Network Communications, Inc. October 30, 2014 Changing Requirements Datacenters are expanding in size. Continued need for 100m

More information

SLIDE 1 - COPYRIGHT G. Across the country, Across the Data Centre. Tim Rayner. Optical Engineer, AARNet.

SLIDE 1 - COPYRIGHT G. Across the country, Across the Data Centre. Tim Rayner. Optical Engineer, AARNet. SLIDE 1 - COPYRIGHT 2015 100G Across the country, Across the Data Centre Tim Rayner Optical Engineer, AARNet Tim.Rayner@AARNet.edu.au Agenda SLIDE 2 - COPYRIGHT 2015 Review of 10G, 40G &100G Standards

More information

Fiber Optic Cabling Systems for High Performance Applications

Fiber Optic Cabling Systems for High Performance Applications Fiber Optic Cabling Systems for High Performance Applications BICSI Conference Bangkok, Thailand 17-18 November 2016 Nicholas Yeo, RCDD/NTS/DCDC Data Center Trends Computing evolution Cloud computing Servers

More information

Roadmap to 400 Gigabit Ethernet over Multimode Fiber WHITEPAPER

Roadmap to 400 Gigabit Ethernet over Multimode Fiber WHITEPAPER Roadmap to 400 Gigabit Ethernet over Multimode Fiber WHITEPAPER The unprecedented exponential growth of information technology (IT) data is not a new finding. What is new is that there is now an end in

More information

Arista 400G Transceivers and Cables: Q&A

Arista 400G Transceivers and Cables: Q&A Arista 400G Transceivers and Cables: Q&A What are the benefits of moving to 400G technology? 400G Transceivers and Cables Q&A Arista s 400G platforms allow data centers and high-performance computing environments

More information

400GE at the Cost of 4 x 100GE

400GE at the Cost of 4 x 100GE 400GE at the Cost of 4 x 100GE Jeffery J. Maki Distinguished Engineer, Optical Juniper Networks, Inc. May 17, 2013 400 Gb/s Ethernet Study Group Victoria BC, Canada, May 2013 400GE over SMF by using the

More information

Cisco 100GBASE QSFP-100G Modules

Cisco 100GBASE QSFP-100G Modules Data Sheet Cisco 100GBASE QSFP-100G Modules Product Overview The Cisco 100GBASE Quad Small Form-Factor Pluggable (QSFP) portfolio offers customers a wide variety of high-density and low-power 100 Gigabit

More information

NGBASE-T Cabling Requirements

NGBASE-T Cabling Requirements NGBASE-T Cabling Requirements Dr. T. C. Tan, DMTS, CommScope Labs B.Sc (Eng), DIC, PhD, CEng, FIET White paper www.commscope.com Contents Contents Contents 2 1.0 Introduction 3 2.0 IEEE 802.3 NGBASE-T

More information

100G and Beyond: high-density Ethernet interconnects

100G and Beyond: high-density Ethernet interconnects 100G and Beyond: high-density Ethernet interconnects Kapil Shrikhande Sr. Principal Engineer, CTO Office Force10 Networks MIT MicroPhotonics Center Spring Meeting April 5, 2011 [ 1 ] Ethernet applications

More information

OFC/NFOEC 2011 Interoperability Demonstration

OFC/NFOEC 2011 Interoperability Demonstration OFC/NFOEC 2011 Interoperability Demonstration March 7, 2011 1. Overview The Ethernet Alliance has twelve members participating in the OFC/NFOEC 2011 demonstration. The participating companies include:

More information

DELL EMC NETWORKING TRANSCEIVERS AND CABLES

DELL EMC NETWORKING TRANSCEIVERS AND CABLES DELL EMC NETWORKING TRANSCEIVERS AND CABLES Features and benefits Hot-swappable for simplified maintenance (no power-down required for installation or replacement) Some of the smallest and lowestpower

More information

Ethernet 100G and Beyond

Ethernet 100G and Beyond Ethernet 100G and Beyond Steve Jones Phone: +44 7900 881729 steve.jones@hubersuhner.com www.hubersuhner.com www.cubeoptics.com blog.cubeoptics.com We don t want this to be you 2 Global Data Center Traffic

More information

Trends in Testing Data Center Infrastructure. Ed Gastle VIAVI Solutions

Trends in Testing Data Center Infrastructure. Ed Gastle VIAVI Solutions Trends in Testing Data Center Infrastructure Ed Gastle VIAVI Solutions Agenda INTRODUCTION Modern Data Center Architecture Historically Enterprise has been a 3 tier topology Core, Aggregation, Access Cloud

More information

Optics Modules and Cables Data Sheet

Optics Modules and Cables Data Sheet Optics Modules and Cables Data Sheet Key Features Deployment flexibility of 100GbE, 40GbE, 25GbE, 10GbE or 1GbE modules Smallest and lowest power SFP optic module form factor for 1GbE, 10GbE and 25GbE

More information

100 GBE AND BEYOND. Diagram courtesy of the CFP MSA Brocade Communications Systems, Inc. v /11/21

100 GBE AND BEYOND. Diagram courtesy of the CFP MSA Brocade Communications Systems, Inc. v /11/21 100 GBE AND BEYOND 2011 Brocade Communications Systems, Inc. Diagram courtesy of the CFP MSA. v1.4 2011/11/21 Current State of the Industry 10 Electrical Fundamental 1 st generation technology constraints

More information

A Fork in the Road OM5 vs. Single-Mode in the Data Center. Gary Bernstein, Sr. Director, Product Management, Network Solutions

A Fork in the Road OM5 vs. Single-Mode in the Data Center. Gary Bernstein, Sr. Director, Product Management, Network Solutions A Fork in the Road OM5 vs. Single-Mode in the Data Center Gary Bernstein, Sr. Director, Product Management, Network Solutions Outline Definition of Enterprise and Cloud Data Centers The Growth of Cloud

More information

Dell Networking Optics and Cables Connectivity Guide

Dell Networking Optics and Cables Connectivity Guide Dell Networking and Cables Connectivity Guide 1 Gigabit Ethernet (1GbE) 10 Gigabit Ethernet (10GbE) 40 Gigabit Ethernet (40GbE) 100 Gigabit Ethernet (100GbE) Fibre Channel Networking I/O Connectivity Options

More information

ExtremeSwitching TM. 100Gb Ethernet QSFP28 Transceivers and Cables. Product Overview. Data Sheet. Highlights. 100Gb Ethernet QSFP28 SR4 MMF

ExtremeSwitching TM. 100Gb Ethernet QSFP28 Transceivers and Cables. Product Overview. Data Sheet. Highlights. 100Gb Ethernet QSFP28 SR4 MMF Data Sheet Highlights Compact Quad Small Form-factor Pluggable (QSFP28) products for high density 100Gb Ethernet applications Hot swappable, field serviceable modular interfaces for Extreme Networks switches

More information

WHITE PAPER THE CASE FOR 25 AND 50 GIGABIT ETHERNET WHITE PAPER

WHITE PAPER THE CASE FOR 25 AND 50 GIGABIT ETHERNET WHITE PAPER THE CASE FOR 25 AND 50 GIGABIT ETHERNET OVERVIEW The demand for cloud-based solutions has grown rapidly, leaving many datacenters hungry for bandwidth. This has created a demand for cost-effective solutions

More information

Delivering100G and Beyond. Steve Jones Phone: blog.cubeoptics.

Delivering100G and Beyond. Steve Jones Phone: blog.cubeoptics. Delivering100G and Beyond Steve Jones Phone: +44 7900 881729 steve.jones@hubersuhner.com www.hubersuhner.com www.cubeoptics.com blog.cubeoptics.com We don t want this to be you 2 100G Access/Metro Figures

More information

Cisco 40GBASE QSFP Modules

Cisco 40GBASE QSFP Modules Data Sheet Cisco 40GBASE QSFP Modules Product Overview The Cisco 40GBASE QSFP (Quad Small Form-Factor Pluggable) portfolio offers customers a wide variety of high-density and low-power 40 Gigabit Ethernet

More information

Next-gen 400 and 200 Gb/s PHYs over Fewer MMF Pairs Call For Interest Consensus Presentation. IEEE Draft 0.3

Next-gen 400 and 200 Gb/s PHYs over Fewer MMF Pairs Call For Interest Consensus Presentation. IEEE Draft 0.3 Next-gen 400 and 200 Gb/s PHYs over Fewer MMF Pairs Call For Interest Consensus Presentation IEEE 802.3 Draft 0.3 Agenda Overview Discussion Presenter 1 Presentations Market Drivers Presenter 2 Technical

More information

400G PAM4 The Wave of the Future. Michael G. Furlong - Senior Director, Product Marketing

400G PAM4 The Wave of the Future. Michael G. Furlong - Senior Director, Product Marketing 400G The Wave of the Future Michael G. Furlong - Senior Director, Product Marketing mfurlong@inphi.com ECOC 2017 100G is Ramping in the Cloud 100G Now Shipping (~2H2016) Numerous Market Reports Millions

More information

within IEEE Alan Flatman LAN Technologies

within IEEE Alan Flatman LAN Technologies Ethernet Developments within IEEE Alan Flatman Principal Consultant Principal Consultant LAN Technologies Focal Points Bandwidth Growth Technology Choice What s Next? Market Trends Copper vs. Fibre 5 Generations

More information

Cisco 100GBASE QSFP-100G Modules

Cisco 100GBASE QSFP-100G Modules Data Sheet Cisco 100GBASE QSFP-100G Modules Product Overview The Cisco 100GBASE Quad Small Form-Factor Pluggable (QSFP) portfolio offers customers a wide variety of high-density and low-power 100 Gigabit

More information

Cabling Solutions for Nexus 9000 Switches With Dual-Rate 40/100G BiDi Transceiver and Panduit Connectivity

Cabling Solutions for Nexus 9000 Switches With Dual-Rate 40/100G BiDi Transceiver and Panduit Connectivity Cabling Solutions for Nexus 9000 Switches With Dual-Rate 40/100G BiDi Transceiver and Panduit Connectivity Introduction Virtualization and cloud technologies have applied an incredible amount of pressure

More information

Tim Takala RCDD. Vice President Field Application Engineer APAC. Mobility is Driving Changing Network Architectures & Transceiver Evolutions

Tim Takala RCDD. Vice President Field Application Engineer APAC. Mobility is Driving Changing Network Architectures & Transceiver Evolutions Tim Takala RCDD Vice President Field Application Engineer APAC Mobility is Driving Changing Network Architectures & Transceiver Evolutions 5TOP TRENDS SHAPING NETWORKS 1. Mobility 2. Connected Devices

More information

40 Gigabit and 100 Gigabit Ethernet Are Here!

40 Gigabit and 100 Gigabit Ethernet Are Here! WHITE PAPER www.brocade.com High- Performance Networks 40 Gigabit and 100 Gigabit Ethernet Are Here! The 40 Gigabit and 100 Gigabit Ethernet standards were adopted by the Institute of Electrical and Electronics

More information

Ethernet The Next Generation

Ethernet The Next Generation Ethernet The Next Generation John D Ambrosia Chair, IEEE P802.3ba Task Force Scientist Sr., Components Technology Force10 Networks Presented by: Debbie Montano dmontano@force10networks.com Per IEEE-SA

More information

Optics Modules and Cables Data Sheet

Optics Modules and Cables Data Sheet Key Features Deployment flexibility of 100GbE, 40GbE, 10GbE or 1GbE modules Smallest and lowest power 10GbE optic module form factor Hot swappable to maximize uptime and simplify serviceability SFP+ Optical

More information

LAN Standards, News & Trends Update 2017 June 15, 2017

LAN Standards, News & Trends Update 2017 June 15, 2017 LAN Standards, News & Trends Update 2017 June 15, 2017 Greg Olson Jtech Systems, Inc Infrastructure Specialist Greg@jtechreps.com 425-437-1962 Our Objectives Review new & ongoing applications work in IEEE

More information

Fast Lanes and Speed Bumps on the Road To Higher-Performance, Higher-Speed Networking

Fast Lanes and Speed Bumps on the Road To Higher-Performance, Higher-Speed Networking Fast Lanes and Speed Bumps on the Road To Higher-Performance, Higher-Speed Networking Bruce Tolley Linux Foundation End User Summit, 24 June 2014 Copyright 2013 Solarflare Communica9ons, Inc. All rights

More information

IEEE Working Group November 2014 Plenary Week

IEEE Working Group November 2014 Plenary Week IEEE 802.3 Working Group November 2014 Plenary Week David Law Chair, IEEE 802.3 Working Group dlaw@hp.com Web site: www.ieee802.org/3 Page 1 Current IEEE 802.3 activities IEEE 802.3 Task Forces IEEE P802.3bm

More information

Pivotal Issues for 400 Gb/s Ethernet

Pivotal Issues for 400 Gb/s Ethernet Pivotal Issues for 400 Gb/s Ethernet Jeffery J. Maki Distinguished Engineer, Optical Juniper Networks IEEE P802.3bs 400GbE Task Force Norfolk, VA, May 2014 Outline 400G Reach Objectives Optical Lanes Cabling

More information

100 GIGABIT ETHERNET. So we ve got 802.3ba, now what do we do with it? Chris Bull Service Provider ANZ

100 GIGABIT ETHERNET. So we ve got 802.3ba, now what do we do with it? Chris Bull Service Provider ANZ 100 GIGABIT ETHERNET Chris Bull Service Provider Systems Engineer ANZ So we ve got 802.3ba, now what do we do with it? Standards How we got to 802.3ba 2011 Brocade Communications Systems, Inc. 2 Summary

More information

Higher Speed Ethernet

Higher Speed Ethernet 1 Higher Speed Ethernet Agenda 100 GbE Technology Requirements IEEE P802.3ba Standards Update 2 What is Driving the Need for 40 GbE and 100 GbE? 3 Research network trends 10 GbE WANs Cluster and grid computing

More information

Scaling the Compute and High Speed Networking Needs of the Data Center with Silicon Photonics ECOC 2017

Scaling the Compute and High Speed Networking Needs of the Data Center with Silicon Photonics ECOC 2017 Scaling the Compute and High Speed Networking Needs of the Data Center with Silicon Photonics ECOC 2017 September 19, 2017 Robert Blum Director, Strategic Marketing and Business Development 1 Data Center

More information

ETHERNET OPTICS TODAY: 25G NRZ

ETHERNET OPTICS TODAY: 25G NRZ ETHERNET OPTICS TODAY: 25G NRZ THE STATE OF ETHERNET OPTICS PANEL Brad Smith, Director of Marketing, LinkX Interconnects, Mellanox March 23, 2016 OFC 2016 Anaheim, CA BradS@Mellanox.com 1GBASE-T CAT5 is

More information

Ethernet Adoption: SERDES Rates & Form Factors

Ethernet Adoption: SERDES Rates & Form Factors Ethernet Adoption: SERDES Rates & Form Factors Jeffery J. Maki IEEE P802.3cd 50 Gb/s, 100 Gb/s, and 200 Gb/s Ethernet Task Force San Diego, CA, July 2016 Supporters Scott Kipp, Brocade Matt Traverso, Cisco

More information

ETHERNET ROADMAP UPDATE. Scott Kipp October 2014

ETHERNET ROADMAP UPDATE. Scott Kipp October 2014 ETHERNET ROADMAP UPDATE Scott Kipp skipp@brocade.com October 2014 1 DISCLAIMER The views expressed in this presentation are the views of the presenter and not of the Ethernet Alliance. 2 Ethernet Roadmap

More information

Fiber in Data Centers What s Next? Srinivasan B, RCDD

Fiber in Data Centers What s Next? Srinivasan B, RCDD Fiber in Data Centers What s Next? Srinivasan B, RCDD Hubbell Fiber Systems 10G / 40G / 100G / 400G Standards, Applications and Practices Agenda Part 1: Current Technologies Standards Review IEEE 802.3:

More information

Building Tomorrow s Networks Session #1: New High-Speed and Long Reach Optical Interfaces. January 20, 2018

Building Tomorrow s Networks Session #1: New High-Speed and Long Reach Optical Interfaces. January 20, 2018 Building Tomorrow s Networks Session #1: New High-Speed and Long Reach Optical Interfaces January 20, 2018 Introductions Panel Organizers John D Ambrosia (Futurewei), Acting Chair, IEEE 802.3 Beyond 10km

More information

What s the technology Buzz at the 2017 Optical Fiber Communications Conference?

What s the technology Buzz at the 2017 Optical Fiber Communications Conference? 40G 100G.400G 800G? What s the technology Buzz at the 2017 Optical Fiber Communications Conference? Lylette Macdonald, RCDD Legrand Data Communications Division lylette.macdonald@legrand.us The Future

More information

DC Network Connectivity

DC Network Connectivity DC Network Connectivity Options & Optimizing TCO Rakesh SAMBARAJU - Application Engineer Nexans Data Center Solutions Agenda l Part I Ethernet Standards and Technologies Ø Current Ethernet Standards Ø

More information

40G and 100G Products

40G and 100G Products 40G and 100G Products QSFP+ esr4 QSFP+ 40G extended range transceiver, in excess of 300m QSFP-40G-SR4 Application The Prolabs QSFP+ esr4 transceiver has been designed to reach distances which can be up

More information

Choosing MPO Connectors for the Data Center. Ken Hall, RCDD, NTS Data Center Architect CommScope

Choosing MPO Connectors for the Data Center. Ken Hall, RCDD, NTS Data Center Architect CommScope Choosing MPO Connectors for the Data Center Ken Hall, RCDD, NTS Data Center Architect CommScope Agenda Network Architecture changes Data Center & MPO Standards Application comparisons Additional considerations

More information

The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures. Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress

The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures. Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress 36 Years of Experience CABLExpress is a manufacturer of

More information

IEEE P802.3ba 40 GbE and 100 GbE Standards Update

IEEE P802.3ba 40 GbE and 100 GbE Standards Update IEEE P802.3ba 40 GbE and 100 GbE Standards Update Greg Hankins RIPE 56 EIX WG RIPE 56 2008/05/08 Per IEEE-SA Standards Board Operations Manual, January 2005 At lectures,

More information

Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications

Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications Optical Trends in the Data Center Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications Higher speeds Higher density Higher reliability Lower capex Lower opex

More information

Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope

Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope Category 8 paves the way for IEEE 40GBASE-T David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope Agenda Market need for 40 G over balanced twisted pair cabling Standards ISO/IEC 11801-99-1

More information

Ethernet Alliance Technology Exploration Forum 2014 The Rate Debate

Ethernet Alliance Technology Exploration Forum 2014 The Rate Debate 1 Ethernet Alliance Technology Exploration Forum 2014 The Rate Debate Session 1: Data Center Speeds Ethernet Alliance Roadmap Introduction Scott Kipp, Brocade Roadmap Subcommittee Vice-Chair President

More information

Future Datacenter Interfaces Based on Existing and Emerging Technologies

Future Datacenter Interfaces Based on Existing and Emerging Technologies Future Datacenter Interfaces Based on Existing and Emerging Technologies Summer Topicals IEEE Photonics Society Waikoloa, Hawaii 8-10 July 2013 Chris Cole Outline 10G Multi-link 10G 40G Serial 40G 100G

More information

Arista 7500 Series Interface Flexibility

Arista 7500 Series Interface Flexibility Arista 7500 Series Interface Flexibility Today s large-scale virtualized datacenters and cloud networks require a mix of 10Gb, 25Gb, 40Gb, 50Gb and 100Gb Ethernet interface speeds able to utilize the widest

More information

Objectives for HSSG. Peter Tomaszewski Scientist, Signal Integrity & Packaging. rev3 IEEE Knoxville Interim Meeting, September 2006

Objectives for HSSG. Peter Tomaszewski Scientist, Signal Integrity & Packaging. rev3 IEEE Knoxville Interim Meeting, September 2006 Objectives for HSSG Peter Tomaszewski Scientist, Signal Integrity & Packaging 1 September 20 21, 2006 rev3 Agenda Propose objectives for: MAC Data Rate Reach Objectives Standardize ygmii Interface BER

More information

IEEE P802.3ba 40 GbE and 100 GbE Standards Update

IEEE P802.3ba 40 GbE and 100 GbE Standards Update IEEE P802.3ba 40 GbE and 100 GbE Standards Update Greg Hankins 1 NANOG 42 NANOG 42 2008/02/19 Per IEEE-SA Standards Board Operations Manual, January 2005 At lectures, symposia,

More information

Pluggable Transceivers Industry standard Pluggable Transceivers and Direct Attach Cables

Pluggable Transceivers Industry standard Pluggable Transceivers and Direct Attach Cables DATASHEET Pluggable Transceivers Industry standard Pluggable Transceivers and Direct Attach Cables Product Overview Modular Ethernet interfaces from 100Mbps to 40Gbps Support for a large variety of cable

More information

100G / Lane Electrical Interfaces for Datacenter Switching - Desirable Solution Attributes

100G / Lane Electrical Interfaces for Datacenter Switching - Desirable Solution Attributes 100G / Lane Electrical Interfaces for Datacenter Switching - Desirable Solution Attributes Rob Stone Geneva, January 2018 1 802.3 100GEL Study Group, Geneva January 2018 Why will datacenters migrate to

More information

ARISTA WHITE PAPER Arista 7500E Series Interface Flexibility

ARISTA WHITE PAPER Arista 7500E Series Interface Flexibility ARISTA WHITE PAPER Arista 7500E Series Interface Flexibility Introduction: Today s large-scale virtualized datacenters and cloud networks require a mix of 10Gb, 40Gb and 100Gb Ethernet interface speeds

More information

CDFP MSA Delivers 400 Gb/s Today

CDFP MSA Delivers 400 Gb/s Today CDFP MSA Delivers 400 Gb/s Today The CDFP Form Factor The CDFP module is the first 400 Gb/s form factor and will enable the highest port and bandwidth density of any pluggable form factor. With a 32mm

More information

Wideband Multimode Fiber What is it and why does it make sense?

Wideband Multimode Fiber What is it and why does it make sense? White Paper Wideband Multimode Fiber What is it and why does it make sense? March, 2015 Contents Executive summary 3 A brief history of MMF 3 The role of fiber connectors 4 Introducing WBMMF 5 2 Executive

More information

100 Gigabit Ethernet. An Industry Update. John D Ambrosia Chair, IEEE P802.3ba Task Force Senior Scientist, Force10 Networks October 8, 2009

100 Gigabit Ethernet. An Industry Update. John D Ambrosia Chair, IEEE P802.3ba Task Force Senior Scientist, Force10 Networks October 8, 2009 100 Gigabit Ethernet An Industry Update John D Ambrosia Chair, IEEE P802.3ba Task Force Senior Scientist, Force10 Networks October 8, 2009 Copyright Copyright 2009 Force10 2009 Force10 Networks, Networks,

More information

Optical multi-speed splitting

Optical multi-speed splitting Optical multi-speed splitting For Xena 00 G and 40 G test modules Xena 00GE and 40GE test modules can support 00 Gbps, 50 Gbps, 40 Gbps, 25 Gbps and 0 Gbps port speeds depending on test module, transceiver

More information

High Speed Migration 100G & Beyond

High Speed Migration 100G & Beyond High Speed Migration 100G & Beyond Moses Ngugi Field Application Engineer 5th September 2017 BANDWIDTH GROWTH Mobile Data IP Video Global Cloud IP Traffic Global IP Traffic Cisco CAGR: 50+% CAGR: 35%+

More information

Overview Brochure Direct attach and active optical cables

Overview Brochure Direct attach and active optical cables Overview Brochure Direct attach and active optical cables Contact us on: Tel: 01189 122 980 Email: sales@cabcon.co.uk www.sterlingcablingsolutions.co.uk Contents High Speed Cables and Transceivers page

More information

PREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND

PREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND PREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND Cindy Montstream, RCDD/NTS, EE, CPLP Director of elearning and Standards DATA COMMUNICATIONS

More information

25 Gb/s Ethernet Study Group CSD: Technical Feasibility. Joel Goergen - Cisco Matt Brown APM Version goergen_25ge_01_0914d

25 Gb/s Ethernet Study Group CSD: Technical Feasibility. Joel Goergen - Cisco Matt Brown APM Version goergen_25ge_01_0914d 25 Gb/s Ethernet Study Group CSD: Technical Feasibility Joel Goergen - Cisco Matt Brown APM Version goergen_25ge_01_0914d Supporters Rich Meltz Intel Brad Booth Microsoft Nathan Tracy TE Kent Lusted Intel

More information

The Dawn of Channelized Ethernet

The Dawn of Channelized Ethernet The Dawn of Channelized Ethernet Nathan Farrington Hot Interconnects 22, Mountain View, CA, USA, August 26-27, 2014 Outline This talk is mostly about parallelism. EtherChannel: Parallelism Going Up Kalpana

More information

Networking Terminology Cheat Sheet

Networking Terminology Cheat Sheet Networking Cheat Sheet YOUR REFERENCE SHEET FOR GOING WEB-SCALE WITH CUMULUS LINUX With Cumulus Linux, you can build a web-scale data center with all the scalability, efficiency and automation available

More information

IEEE Working Group March 2018 Plenary Week

IEEE Working Group March 2018 Plenary Week IEEE 802.3 Working Group March 2018 Plenary Week David Law Chair, IEEE 802.3 Working Group dlaw@hpe.com Web site: www.ieee802.org/3 Page 1 Current IEEE 802.3 activities IEEE 802.3 Task Forces IEEE P802.3bs

More information

Overcoming the Testing Challenges of 40G and Beyond. Eric Farst Channel Sales Manager

Overcoming the Testing Challenges of 40G and Beyond. Eric Farst Channel Sales Manager Overcoming the Testing Challenges of 40G and Beyond Eric Farst Channel Sales Manager Agenda Introduction Increased demand for speed & capacity in the Enterprise/Data Center How Enterprises/Data Centers

More information

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only 1 Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only Gautier Humbert, RCDD Standards Coordinator Digital Infrastructures Legrand District Chair Mainland Europe BICSI 2 Agenda

More information

DC Center Copper Cabling up to 40Gbase-T. Halim Senjaya

DC Center Copper Cabling up to 40Gbase-T. Halim Senjaya DC Center Copper Cabling up to 40Gbase-T Halim Senjaya CTDC CTIA Data Center Expert Datwyler Singapore Diploma in Eng ng in Physics Bandung IT Diploma in Cloud DC Technologies - NP MBA Middlebury Institute

More information

IEEE Working Group March 2014 Plenary Week. David Law Chair, IEEE Working Group Web site:

IEEE Working Group March 2014 Plenary Week. David Law Chair, IEEE Working Group Web site: IEEE 802.3 Working Group March 2014 Plenary Week David Law Chair, IEEE 802.3 Working Group dlaw@hp.com Web site: www.ieee802.org/3 Page 1 Current IEEE 802.3 activities IEEE 802.3 Task Forces IEEE P802.3bj

More information

Solutions Guide. Pluggable Optics for the Data Center

Solutions Guide. Pluggable Optics for the Data Center Solutions Guide Pluggable Optics for the Data Center Pluggable Optics for the Data Center The data center ecosystem is going through unprecedented growth and innovation as new players, new business models

More information

40 and 100 Gigabit Ethernet Overview

40 and 100 Gigabit Ethernet Overview Extreme Networks White Paper 40 and 100 Gigabit Ethernet Overview Abstract This paper takes a look at the main forces that are driving Ethernet bandwidth upwards. It looks at the standards and architectural

More information

High Speed Migration: Choosing the right multimode multi-fiber push on (MPO) system for your data center

High Speed Migration: Choosing the right multimode multi-fiber push on (MPO) system for your data center High Speed Migration: Choosing the right multimode multi-fiber push on (MPO) system for your data center Table of Contents Introduction 3 Figure 1 - The Ethernet road map 3 Planning considerations 4 Fiber

More information

Industry Standards Activity Overview

Industry Standards Activity Overview Industry Standards Activity Overview Most Recent Plenary Meeting: June 12-16, 2017 in Quebec City, QC, CAN Updated: July 7, 2017 TR-42.1 Commercial Building Cabling: TIA TSB-185 Environmental Classification

More information

Testing Parallel Optics

Testing Parallel Optics White Paper Testing Parallel Optics Author: Ed Gastle VIAVI Solutions To accommodate the relentless need for speed, driven by mobile devices, watching videos online and uploading and sharing content, network

More information

Opt-X Unity. Fiber Optic Migration System

Opt-X Unity. Fiber Optic Migration System Opt-X Unity Fiber Optic Migration System PRE-TERMINATED FIBER MIGRATION SYSTEM The Opt-X Unity 40, 100, 200, 400 Gb/s system offers an ideal migration path to speeds beyond 10 GbE, and meets IEEE and MSA

More information

QDR Active Optical Cables. SC 10 New Orleans

QDR Active Optical Cables. SC 10 New Orleans QDR Active Optical Cables SC 10 New Orleans Christian Urricariet (christian.urricariet@finisar.com) November 16, 2010 World s Largest Supplier of Fiber Optic Components Company Highlights Market leader:

More information

Everything you wanted to know about cabling, but were afraid to ask

Everything you wanted to know about cabling, but were afraid to ask Everything you wanted to know about cabling, but were afraid to ask Join the teleconference To receive a call back, click Communicate/Teleconference/Join Teleconference. In the pop-up window, enter your

More information

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards Anticipating Cat 8 Agenda Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards What is Cat 8? Next Generation Copper Cabling 25G and 40G data rates over twisted pair copper

More information

Insuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions. Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions

Insuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions. Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions Insuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions Fiber Optics LAN Section Part of the Telecommunications Industry

More information

Silicon Photonics and the Future of Optical Connectivity in the Data Center

Silicon Photonics and the Future of Optical Connectivity in the Data Center Silicon Photonics and the Future of Optical Connectivity in the Data Center ECOC MARKET FOCUS September 19, 2016 Robert Blum Director, Strategic Marketing and Business Development 1 Data Center Traffic

More information

Don t Get Left Behind: Cabling Designs You Can Trust to Support Speeds of 32G to 400G

Don t Get Left Behind: Cabling Designs You Can Trust to Support Speeds of 32G to 400G Don t Get Left Behind: Cabling Designs You Can Trust to Support Speeds of G to 00G Dave Fredricks Data Center Infrastructure Architect #DATACENTERWORLD #CPEXPO CHANNELPARTNERSCONFERENCE.COM DATACENTERWORLD.COM

More information

Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks

Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks Agenda New ISO/IEC 11801 Standard New Fibre standards and encoding methods Higher speeds,

More information

The Arista Universal transceiver is the first of its kind 40G transceiver that aims at addressing several challenges faced by today s data centers.

The Arista Universal transceiver is the first of its kind 40G transceiver that aims at addressing several challenges faced by today s data centers. ARISTA WHITE PAPER QSFP-40G Universal Transceiver The Arista Universal transceiver is the first of its kind 40G transceiver that aims at addressing several challenges faced by today s data centers. Increased

More information

40 GbE: What, Why & Its Market Potential

40 GbE: What, Why & Its Market Potential 40 GbE: What, Why & Its Market Potential Contributors: Gautam Chanda, Cisco Systems Yinglin (Frank) Yang, CommScope, Inc. November 2010 1 P a g e Table of Contents Executive Summary...3 Introduction: The

More information

Optical Trends in the Data Center

Optical Trends in the Data Center Optical Trends in the Data Center Romeo Lazar Sales Manager, Eastern Europe Corning Optical Communications EMEA September 2016 Agenda Agenda Corning overview Data Center Server and Switch Trends Standards

More information

Active Optical Cable. Optical Interconnection Design Innovator 25G SFP28 AOC 10G SFP+ AOC. Shenzhen Gigalight Technology Co.,Ltd.

Active Optical Cable. Optical Interconnection Design Innovator 25G SFP28 AOC 10G SFP+ AOC. Shenzhen Gigalight Technology Co.,Ltd. Optical Interconnection Design Innovator Active Optical Cable Shenzhen Gigalight Technology Co.,Ltd. Add: 17F, Zhongtai Nanshan Zhujue Building, 4269 Dongbin Road, Nanshan District, Shenzhen, Guangdong

More information

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee Standards Update Mylaraiah J N, RCDD Member, BICSI India Steering Committee Standards Update International Standards Interrelations Reference Guide Standard ISO/IEC CENELEC TIA/EIA Performance / Generic

More information

Leaders in the Advancement of Multimode Fiber. Fiber Future and Beyond

Leaders in the Advancement of Multimode Fiber. Fiber Future and Beyond Leaders in the Advancement of Multimode Fiber Fiber Future and Beyond Major Milestones in the Advancement of Multimode Fiber (MMF) Transmission OM4 Signature Core Fiber Cabling TIA WBMMF ISO/IEC OM5 (WBMMF)

More information

Higher Speed Ethernet Update

Higher Speed Ethernet Update Higher Speed Ethernet Update Greg Hankins 1 RIPE 53 2006/10/05 Per IEEE-SA Standards Board Operations Manual, January 2005 At lectures, symposia, seminars, or educational

More information

Consensus building discussion on next-generation MMF PMDs. Presented by Robert Lingle, Jr. IEEE Interim Huntington Beach, CA January 9 th, 2017

Consensus building discussion on next-generation MMF PMDs. Presented by Robert Lingle, Jr. IEEE Interim Huntington Beach, CA January 9 th, 2017 Consensus building discussion on next-generation MMF PMDs Presented by Robert Lingle, Jr. IEEE 802.3 Interim Huntington Beach, CA January 9 th, 2017 Contributors and Collaborators Supplied materials for

More information

OIF CEI-56G Project Activity

OIF CEI-56G Project Activity OIF CEI-56G Project Activity Progress and Challenges for Next Generation 400G Electrical Links David R Stauffer Kandou Bus, SA OIF Physical & Link Layer Working Group Chair June 12, 2014 Electrical Implementation

More information

Alternate Path to Consensus on 400 GbE PMDs

Alternate Path to Consensus on 400 GbE PMDs Alternate Path to Consensus on 400 GbE PMDs Ali Ghiasi Ghiasi Quantum LLC IEEE 802.3bs Task Force November 2014 Current 802.3bs Objec=ve Per Dallas Mee=ng q Provide physical layer specificahons which support

More information

Trends in Data Centre

Trends in Data Centre Trends in Data Centre The impact on the IT infrastructure Thomas Ko Product Manager Market Situation Standards Update and Topology 40G and 100G Ethernet - Impact on IT Cabling Migration Options with Fiber

More information

IEEE Working Group Interim meeting 17 th September 2015

IEEE Working Group Interim meeting 17 th September 2015 IEEE 802.3 Working Group Interim meeting 17 th September 2015 David Law Chair, IEEE 802.3 Working Group dlaw@hp.com Agenda, voter list: http://www.ieee802.org/3/minutes/sep15/index.html IEEE 802.3 Working

More information