NA762TB High-Performance Thunderbolt Storage User s Guide V1.00 Mar. 9, 2014
|
|
- Janice Eunice McGee
- 5 years ago
- Views:
Transcription
1 NA762TB High-Performance Thunderbolt Storage User s Guide V1.00 Mar. 9, 2014 HighPoint Technologies Inc. 1
2 Table of Contents 1. Introduction SYSTEM REQUIREMENTS What s in the Box? NA762TB Overview Setting up the NA762TB HDD Installation Connecting the NA762TB to a Mac System Install the software for NA762TB Configuring RAID Arrays Configuring RAID Arrays Using the RAID disk with Mac OS X Deleting RAID Storage RAID Disk Failure Recovery Expanding RAID Storage Capacity NA762TB Audible Alarm Technical Support LIMITED WARRANTY APPENDIX A - Using the WebGUI (full guide) APPENDIX B - Web RAID Management ICON Definition List APPENDIX C - RAID Technology Explanation APPENDIX D - Thunderbolt Daisy Chain configuration HighPoint Technologies Inc. 2
3 1. Introduction HighPoint's NA762TB Thunderbolt Storage Solution delivers high-performance, hardware RAID storage from a single cable connection! The fully integrated hardware RAID controller and eight removable disk modules were designed for today's fastest 6 Gb/s storage devices - perfect for professional, I/O intensive applications such as digital content creation and media post production. The NA762TB's robust, stylish aluminum construction ensures your storage stays cool while running at optimum efficiency. Key Features Stylish, compact and Whisper-Quiet Enclosure Thunderbolt interface with 10Gbps of throughput in both channels Eight (3.5 ) SAS/SATA Removable Disk Tray Module RAID level 0, 1, 10, 5, 6, 50, & JBOD Comprehensive Storage Management Suite Simplified Cabling Solution Temperature/fan failure LEDs and mutable buzzer alarm 2. SYSTEM REQUIREMENTS Apple Mac system with Thunderbolt support. Mac OS X 10.8.x or higher 3. What s in the Box? A. NA762TB Enclosure x 1 B. Disk module x 8 (Installed) C. Thunderbolt cable x 1 (2 meters) D. Power Cord x 1 E. Hard Disk Drive mounting screw x 32 F. Key for HDD tray x 2 HighPoint Technologies Inc. 3
4 4. NA762TB Overview Specifications Host Interface : Thunderbolt 10Gbps Bi-directional Controller & RAID Feature : Supports RAID Level 0, 1, 10, 5, 6, 50, Single Disk or JBOD Multiple RAID Selection Online Array Roaming Greater than 2TB Capacity per Disk Drive Support Storage : Supports up to 8 SAS/SATA 3Gb/s or 6Gb/s 3.5" HDDs (Hard Disks Sold Separately) Stylish Aluminum Housing with Solid Metal Structure Thunderbolt Port for Daisy-chain up to 6 Devices Individual Key lock of each HDD tray for physical security Monitors/Indicators : Web base GUI RAID Manager for Remote Management SMTP Support for Notification FAN fail LED Over Temperature LED HDD fail LEDs Cooling Fans: Two 80x 80x 25mm Hot-Swappable HighPoint Technologies Inc. 4
5 Power Supply: Server-grade 300W Single Power Supply Low-noise Design Universal: 100~240VAC, 50/60Hz Environmental Requirements: Operation Temperature: 5 C ~ 50 C Storage Temperature: -20 C~ 70 C Operation Humidity: 10% ~ 80%, non-condensing Storage Humidity: 5% ~ 95% Dimensions : 231(D) x 156(W) x 365(H) mm 9.1(D) x 6.1(W) x 14.4(H) inch Operating System Support: Mac OS X 10.6.x/ 10.7.x/ 10.8.x /10.9.x (Driver was integrated by Apple OS X 10.9.x) Scalability : Thunderbolt port for daisy-chain up to 6 devices Panel Layout 1. HDD Power LED: White - Power On Indicator 2. HDD Status LED: Flash Blue - HDD Access Indicator, Red - HDD Failure Indicator 3. Power on LED: White - Enclosure power on 4. Fan Status LED: Normal - Green, Failure - Red (too slow RPM or stop) 5. Temperature LED: Normal - Green; Over-temperature - Red HighPoint Technologies Inc. 5
6 6. Mute Button: Reset for Buzzer Beeping 7. Thunderbolt connectors: Connecting Thunderbolt cables to host, upstream and downstream device 8. Hot-swappable cooling fans 9. Power cord receptacle 10. Power switch 5. Setting up the NA762TB 5.1 HDD Installation The NA762TB has 8 Disk modules. It can support both SATA and SAS hard disk drives. Note: Use only enterprise RAID edition series hard disks for RAID applications. step 1. Place the NA762TB on a level surface and remove each disk module. step 2. Carefully insert the HDD into each disk module and secure them with the provided mounting screws. Once complete, insert each disk module back into the front panel of the NA762TB. HighPoint Technologies Inc. 6
7 5.2 Connecting the NA762TB to a Mac System. step 1. Connect the NA762TB to the host system with the Thunderbolt cable, and then connect the NA762TB with a power source. step 2. With the power cord connected to the power source, turn on the NA672TB using the power switch on the rear panel (switch to the I position to power on the NA762TB). Note: The NA762TB is designed to be powered on and powered off simultaneously with the HOST system, when the NA762TB is connected to the HOST system with the Thunderbolt cable. Therefore, power on HOST first the NA762TB will automatically power on. (NA762TB supports hot-plug and hot-unplug for powering-on and powering-off) 5.3 Install the software for NA762TB 1) Driver installation. step 1. Driver Installation. Please visit ( for the latest driver package. Once downloaded, unzip the package, and follow the procedure below: a. Double-click the uninstall.command script file to uninstall the currently installed driver. b. Double-click the HighPointIOP.mpkg icon to install the driver package. You will be asked to input the administrator s password in order to complete this. Once HighPoint Technologies Inc. 7
8 complete, you will be asked to reboot the system. Confirm the prompt to proceed. step 2. Verifying driver installation. After the driver has been installed and the system rebooted, verify the NA762TB device status using OS X System Information pane. To verify the NA762TB driver status; Click the Apple icon on top left of the screen, and select About This Mac, and then select More Info. Next, select System Report, and click PCI Cards on left side of the System Information pane. The Driver Installed entry for controller pci1103, 4520 should be Yes 2) RAID Management software installation. All hard disks installed into the NA762TB will be configured as single drives by default, and will be recognized by OS X Disk Utility. In order to configure RAID array you will need to install the Web RAID Management software (also known as the WebGUI). step 1. WebGUI Installation Download and install the RAID Management software from the NA762TB product page: step 2. Running the WebGUI HighPoint Technologies Inc. 8
9 Unzip the package and double-click the HighPoint WebGUI icon to install WebGUI. You ll be asked to input system administrator s password to complete installation. After installation is complete, a WebGUI icon will be displayed on desktop screen. Double-click this icon to open the WebGUI. The system s default web browser will open a login page. To login, use the default user name: RAID and password: hpt. 6. Configuring RAID Arrays 6.1 Configuring RAID Arrays The NA762TB RAID controller supports multiple RAID levels. The steps below describe how to quickly configure a RAID5 array. step 1. Verify the physical device status. Click the Physical tab to make sure all of the HDD s are detected. Each drive will be designated as Device 1-N, where N refers to the disk module number. Click device icon, it will display detail device information. If any of the disks are not detected, check the corresponding disk module and make sure the drive is securely installed (see page 6 for more information). HighPoint Technologies Inc. 9
10 step 2. Verify the Logical Device status. Click the Logical tab to check if any of the disks were previously part of another RAID array. If a RAID configuration is reported, click on Maintenance, displayed toward the right of the Status column and delete the array. Back up data first if you need to keep the data on this array before doing array deletion. step 3. Creating a RAID Array. HighPoint Technologies Inc. 10
11 The following procedure demonstrates how to configure a RAID5 array. A RAID5 array s usable capacity is calculated using the following formula: N-1, multiplied by the capacity of the smallest disk (where N refer to the total number of disks). For more detailed instructions, see section 4.1 Logical: Create Array, on page 20. Note: We recommend using identical hard disk when creating a RAID array. In addition, only use enterprise class RAID edition hard drives. Follow the steps below to create a RAID 5 Array. A. Click the Create Array button on the left panel. B. Select the Array Type (RAID level): RAID 5 C. Select the Initialization Method: Foreground Note: For RAID5, only foreground or background initialization is recommended. The initialization time is dependent on array capacity. The initialization process will zero out all disks so a correct parity can be generated during disk writes. Correct, consistent parity information is essential for the integrity of data when rebuilding RAID 5 arrays. D. Select the Available Disks: Click the Select all button. E. Click the Create button to create the array. HighPoint Technologies Inc. 11
12 The following diagram displays RAID5 foreground initialization in progress. step 4. After the array has been created, it will be displayed under the Logical tab. HighPoint Technologies Inc. 12
13 6.2 Using the RAID disk with Mac OS X. A newly created RAID Array will be recognized as an empty disk. OS X must initialize it before it can be used. step 1. Initializing the RAID disk. After a RAID array has been created, OS X will display a pop-up window with options to initialize, Ignore or Eject. Click Initialize to open Disk Utility. step 2. Erase the Disk Select the RAID volume, and select the Erase tab. Enter a name in the Name: field, and click the Erase button towards the bottom right-hand corner to format the array. Once complete, the RAID array will be ready for use, and will be mounted on the desktop. HighPoint Technologies Inc. 13
14 After the RAID disk is erased, the RAID5 disk volume icon will be found on the desktop and finder as a new disk volume. step 3. Ejecting the RAID array To eject the RAID array using Mac OS X, select Go from the Desktop, and select Computer. Click on the RAID array (it will be displayed using the name you selected on step 2), and click on File. Select Eject from the drop-down menu to eject the RAID array. Note: The NA762TB supports Thunderbolt power management. While the NA762TB is connected to the host system using the Thunderbolt cable, shutting down the host will automatically power down the NA762TB HighPoint Technologies Inc. 14
15 7. Deleting RAID Storage To delete a RAID array: 1) Log-in to the WebGUI. 2) Switch to the Logical tab. 3) Locate the RAID array that you wish to delete. 4) Click the Maintenance link to the right of the RAID array. 5) Click the Delete button from the Array Maintenance pop up window. 6) Confirm the deletion by click OK button. Note: All data on the selected RAID array will be deleted after you confirm this selection. 8. RAID Disk Failure Recovery The NA762TB s RAID controller continually monitors the health of each of the disk drives. In the event of a disk failure, an audible alarm will sound. The web GUI will also report the failed drive and its physical position. NOTE: For redundant RAID arrays (RAID 1, 5, 6, 10 or 50), a drive failure does not result in data loss. However, the array is now in an unprotected state and the failed drive should be replaced as soon as possible to avoid data loss. HighPoint Technologies Inc. 15
16 NOTE: If the NA762TB was configured in RAID 6 mode, up to two drives can fail with no loss of data. Replace any failed drive as soon as possible. Follow the steps below to identify and replace a failed drive. 1) Launch the WebGUI 2) Mute the alarm with the Beeper Mute button. 3) The WebGUI will display information like that shown below. An exclamation mark on the RAID array icon indicates that the Status of the array is Critical. The lower portion of the GUI indicates which drive in which disk unit has failed. Note: In this example drive 4 of the RAID 5 Array of has failed. 4) Unlock the disk module Key and remove the failed drive by gently sliding the drive module out of the enclosure. WARNING: Make absolutely sure that you remove the failed drive indicated by the GUI. The HDD status LED can also help locate the Failed disk. When the disk has failed, the NA762TB s HDD status LED will emit a solid red light. Reinstall the disk module immediately if you remove the wrong disk module. 5) Replace the failed drive with a new disk module and secure in place. Once the drive has spun up to speed, the GUI will indicate that the array is rebuilding (The Status shows Rebuilding and the percentage complete) as shown below. The rebuild time is approximately 2 hours per TB. 6) Once the rebuild is complete, the RAID array will return to the Normal status. Your data is now secure. HighPoint Technologies Inc. 16
17 9. Expanding RAID Storage Capacity Note: Mac OS X cannot support partition expansion DO NOT attempt to use the WebGUI s OCE or ORLM functions with a Mac system. To Expand RAID storage capacity: a. Back up all original data to a separate storage device. b. Delete the current RAID array c. Create a new array using the original and added disks. d. Restore the data from the backup source to the new array. 10. NA762TB Audible Alarm The NA762TB has two internal Alarm buzzers. These two Alarm buzzers will emit different types of sound when an error condition is detected Storage controller buzzer: This buzzer is for HDD failure (offline) status notification and it will emit a high pitch continuous sound. This alarm will sound when a disk failure occurs or a disk or an array is removed without using the unplug feature in the WebGUI. When the sound is triggered, follow the steps below to check the HDD status and mute the alarm. a. Open the WebGUI and switch to the logical tab. The alarm can be stopped using the WebGUI s Mute button, or the Rescan function found under the Physical or Logical tabs. b. Check the physical device status if there are any disabled drives. c. Locate the disk module number. The NA762TB s HDD status LED will emit a solid red light if a disk has failed. Check the HDD status LED and locate the failed disk. d. If the RAID is in critical status, please follow Chapter 8 RAID Disk Failure Recovery to recover the RAID disk e. For other RAID status, please refer p.37 for RAID recovery 10.2 Enclosure buzzer The alarm buzzer will emit an intermittent sound when a cooling fan has failed, or the enclosure is overheating. Follow the steps below to check the enclosure status and mute the alarm. a. Use the mute button on the front panel of NA762TB to mute the alarm. b. Check if the FAN and Temperature LED from the front panel of NA762TB is light on red. c. If the enclosure alarm actives, this is usually related to NA762TB hardware problem. Please contact Technical Support and report the issue. HighPoint Technologies Inc. 17
18 11. Technical Support If you encounter any problems while utilizing the HighPoint NA762TB, or have any questions about this or any other HighPoint Technologies, Inc. product, feel free to contact our Customer Support Department. Web Support: Thunderbolt Support: Phone: (408) Skype: HighPoint.Thunderbolt 12. LIMITED WARRANTY HighPoint warrants your Product against any defect in material and workmanship, under normal use, for the designated warranty period. If the Product should become defective within the warranty period, HighPoint will at its discretion, repair or replace the Product. Repair or replacement parts or Products will be furnished on an exchange basis and will be either new or reconditioned. All replaced parts or Products shall become the Property of HighPoint. This warranty shall not apply if the Product has been damaged by accident, misuse, abuse or as a result of unauthorized service or parts. Warranty service is available to the purchaser by obtaining a Return Material Authorization number (RMA) and by delivering the Product during the warranty period to an authorized HighPoint service facility or to HighPoint. The purchaser shall bear all shipping, packing and insurance costs and all other costs, excluding parts and labor, necessary to effectuate repair, replacement or refund under this warranty. All returned products must be shipped to HighPoint in the original shipping container. For more information on how to obtain warranty service, an RMA number or to acquire shipping materials, contact HighPoint Technical Support. The support information is listed on Chapter 11 section. IN THE EVENT A PRODUCT BECOMES DEFECTIVE DURING THE WARRANTY PERIOD, THE PURCHASER S EXCLUSIVE REMEDY SHALL BE REPAIR OR REPLACEMENT AS PROVIDED ABOVE. INCIDENTAL OR CONSEPROUENTAL DAMAGES, INCLUDING WITHOUT LIMITATION LOSS OF DATA, ARISING FROM BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ARE NOT THE RESPONSIBILITY OF GTECH AND, TO THE EXTENT PERMITTED BY LAW, ARE HEREBY EXCLUDED BOTH FOR PROPERTY DAMAGE, AND TO THE EXTENT NOT UNCONSCIONABLE, FOR PERSONAL INJURY DAMAGE HighPoint Technologies Inc. 18
19 APPENDIX A - Using the WebGUI (full guide) HighPoint s web-based RAID Management Software (also known as the WebGUI) is used to monitor and configure hard disks and RAID arrays attached to HighPoint RocketRAID host adapter which is intergraded to the NA762TB. 1. Running the HighPoint Web RAID Management software (WebGUI) After downloading and installing the WebGUI, open the WebGUI by double-clicking the icon found on the desktop: Login to the WebGUI and configure the RAID arrays. Use the default user name: RAID and password: hpt to login Remote Login Users connected to a local network can remotely access the WebGUI through the IP address the machine is located on. Open a terminal and type in the following command: ifconfig Once the IP address is obtained users can remotely access the machine by typing in the following address: Address:7402 HighPoint Technologies Inc. 19
20 2. Web RAID Management Software - Global View A Controller(0): Drop-down menu that displays the controller that is currently being managed. B Host Adapter Model: Name of the RAID controller C Enclosure Count: Total number of HighPoint Rocket EJ (Port Multiplier) devices connected. It should be always 0 D Physical Drive: Total physical drives detected by this RAID controller E Legacy Disk: Total physical drives which has partition information created detected by this RAID controller F RAID Count Total RAID array count has been detected by this RAID controller G Total Capacity: Total capacity of all detected HDD s H Configured Capacity: Total GB of capacity configured for in Logical devices I Free Capacity: Total GB of capacity that is free for use in creating a JBOD or RAID array HighPoint Technologies Inc. 20
21 3. Web RAID Management Software - Physical 3.1 Physical - Controller A. Controller Information It lists the following controller information Model Name: RAID controller model number BIOS Version: RAID controller BIOS version Vendor: Vendor Name PCI Bus Number: PCI slot information PCI Device Number: PCI device number PCI Func Number: PCI function number B. Extended Information It lists controller other information such as processor type, temperatures, voltage, SDRAM, Battery, Firmware version, and SAS address. C. Update Firmware Controller BIOS/Firmware can be update from Physical page. Browse for BIOS image and click the Submit button. HighPoint Technologies Inc. 21
22 3.2 Physical - Devices A. Physical Device Information: Itlists devices attached to this controller. Information includes disk model name and capacity. B. By clicking device icon, it displays detail device properties Unplug: Powers off the device or RAID array and allow you to remove the device Model: Device model information Revision: Firmware revision Location: Location number of the device on the RAID controller Max Free: Max free space for creating a single disk JBOD or to be part of a RAID array Status: Device status is Legacy or Normal Serial Serial Number of device Number: Capacity: Total capacity of the device Read Ahead: Caching mode to improve Read performance Write Cache: Caching mode to improve Write performance NCQ: Native Command Queuing, I/O commands that are in a queue are re-ordered for better efficiency HighPoint Technologies Inc. 22
23 Identify LED: A blinking cursor to identify the location of a HDD 3.3 Physical - Rescan The item will rescan the controller to detect devices. 4 Web RAID Management Software - Logical A. Logical Device Information: It is the logical disk that is connected to the RAID controller and has already been reported to the operating system. Example: Mac OSX Disk Utility B. Physical Device Information: The physical disk attached to the RAID controller. 4.1 Logical - Create Array To create an array, users need to provide information to tell utility how to construct this array. This section gives a detail description. The following diagram shows the creation page. HighPoint Technologies Inc. 23
24 A. Array Type Choose the RAID type to create. The NA762TB s RAID controller supports RAID 0, 1, 5, 6, 10, 50 & JBOD. HighPoint Technologies Inc. 24
25 B. Array Name Enter the name for the RAID array. C. Initialization Method The initialization of array is to clean up array disk so there is no invalid data exists. This is essential for array with parity information. During data rebuilding, only valid parity data can re-construct the correct data. There are four options to choose from. 1. Keep Old Data: This is the default option when creating a RAID array. a. This option leaves existing data intact. b. This option does not initialize the array disk. You can use this option when creating RAID arrays with new hard disks (initialization is not generally necessary for new drives, as they contain no data). c. In some cases, this option can be used to recover disabled RAID arrays. 2. Quick Init: The RAID array will be immediately accessible. a. This option will delete all content on the disks. b. This option will not perform disk array initialization. When new HDD s are used this option can be ignored since there is no data on the hard disk. 3. Foreground: The RAID array is not accessible until initialization is completed. a. This option will delete all content on the disks. b. The logical disks will not be reported to the operating system until initialization is complete. This method is faster than Background, and requires far less time to complete. 4. Background: The RAID array is accessible while disk initialization is being performed. a. This option will delete all content on the disks. b. This method will slow the initialization process, but allows the array to be utilized immediately HighPoint Technologies Inc. 25
26 D. Cache Policy Two options are available when creating redundant RAID arrays (1, 5, 6, 10, 50). 1. Write Back Provides higher write performance for redundant RAID arrays. Data is at risk when there is a power failure, system kernel panic and/or the system is not responsive. 2. Write Through Provides superior data protection when there is a power failure. Data is written directly to disk. E. Block Size Block sizes are adjustable from 16K through 1024K, default is 64K F. Number of RAID5 member disks This option is related to creating a RAID 50 array. G. Select All HighPoint Technologies Inc. 26
27 User can select how many disks to construct the array or click this select all to use all HDDs for the array creation. H. Capacity This allows users to define how much disk capacity will be used. If maximum is chosen, then it means use all calculated available disk space. After the array has been created, it will be displayed under Logical Device Information (4.3). The following information is displayed for each logical device: Name: Type: Capacity: Cache Policy: Block Size: Sector Size: OS Name: Status: Default name of the RAID array Type of RAID array Total capacity of the RAID array Redundant RAID array options for performance or protection RAID array block size RAID array sector size Name of HDD seen in the OS Status of RAID array. Other option include (Normal, Critical, Disable, Rebuilding, Verifying) Array Maintenance: Maintenance provides a selection of general maintenance features and options for the selected array: 1. Diagram 1: Array is in Normal Status HighPoint Technologies Inc. 27
28 2. Diagram 2: Array is in Critical status The arrays current status and RAID level determine which options and features are provided by Maintenance: 1. Delete : Delete the selected RAID array 2. Unplug : Power off the RAID array and remove it. Without using this feature, removing any disk member will trigger the alarm. 3. Verify : This option is only available when RAID is in Normal status. 4. Add : This option is only available when RAID is in Critical status. Click the add disk button to add a new disk in. The following diagram shows how to add a free disk to join the critical array rebuilding. HighPoint Technologies Inc. 28
29 5. Rebuild: Add a disk and rebuild a critical RAID array to normal. The following diagram shows rebuilding array in processing. 6. Change cache Policy: Toggle Between Write Through and Write Back Write Through: Lower write performance because data is written directly to HDD. Data cannot be lost due to power failure or some other circumstance. Write Back: Higher write performance but chances of data lose are greater since data still resides in cache 7. Rename: Rename the array other than the default 4.2 Logical - Spare Pool When creating redundant RAID arrays (1, 5, 6, 10 or 50) a Spare HDD can be configured to automatically help rebuild a degraded redundant RAID. Users can assign any free storage into spare pool. And any disk is in spare pool can be removed as well. The following diagrams show how to operate spare pool. HighPoint Technologies Inc. 29
30 4.3 Logical Logical Device Displays logical devices hosted by the NA762TB. HighPoint Technologies Inc. 30
31 4.4 Logical - Rescan When hot-plugging a single device or RAID array, the Rescan button prompts the RAID controller to scan for device changes. 4.5 Logical - Beeper Mute This will temporarily disable the internal speaker on the RAID controller. 5 Web RAID Management Software - Setting This tab displays various controller settings and options: 5.1 Setting - System A. Enable auto rebuild: If enabled, any new disk attached to the RAID controller will be used to rebuild the critical RAID array. B. Enable Continue Rebuilding on error: Note: The new disk needs to be equal to or larger than the minimum capacity among the remaining disk members of the array. Enabled by default. If disabled, the WebGUI will ignore bad sectors/read failures and allow the rebuild process to continue. Warning: this option should only be enabled in the case of an emergency data inconsistency or data loss may result. Review the Event Log before enabling this option, and check for HDD bad HighPoint Technologies Inc. 31
32 sector events. If bad sectors are found, we recommend first contacting the HDD manufacturer, then technical support, for further advice. C. Enable audible alarm: D. Set Spindown Idle Disk (Minutes): E. Restrict to localhost access: When a disk goes off-line the beeper on the RAID controller will sound. Hard drives can be instructed to spin down when there is no disk activity for a set period of time. You are free to specify the interval from 10 to 240 minutes. This option is used to restrict WebGUI access to the local system and not allowing remote access. F. Set Rebuild Priority: When rebuilding a critical RAID array, there are five rebuilding options to choose from. Each rebuild priority will affect the rebuild completion time. Lowest Lowest Priority when rebuilding arrays. System resources will be assigned to all other tasks first. Low Low Priority. Most of the system s tasks have priority over the rebuild procedure. Medium Medium Priority is the default option system resources are equally distributed between the rebuild procedure and other system tasks. High High Priority the majority of available system resources will be directed towards the rebuild procedure. HighPoint Technologies Inc. 32
33 Highest Highest Priority the RAID controller will utilize all available system resources to rebuild the array. G. Port Number 7402: The listening port number used to log into the WebGUI is the default port number. Other port numbers can be used in place of the default as long as they are free. H. Password Setting: The default password hpt can be changed. Note: If the current password is lost or forgotten, you can uninstall and reinstall the Web RAID Management software to restore the default settings. When changing the password, the maximum number of characters allowed is eight. 5.2 Setting - The NA762TB s RAID controller can be configured to send Event Log entries to one or more addresses. The setting has SMTP setting and recipient which users need to configure it HighPoint Technologies Inc. 33
34 A. Enable Event Check this item to enable Event Notification Notification: B. Server address: This is SMTP mail server address. It can be IP address or SMTP name C. Mail From: This is address of the sender D. Login Name: The login name of send s account E. Password: The login password of send s account F. SMTP Port: This is SMTP port number. The default is 25 for non-ssl SMTP server G. Support SSL: Check this box if using SSL SMTP and change SMTP port to SSL port number. Click Change setting to save new information. H. Support SSL: Setup the recipient s address I. Name: The name of the recipient J. Event level Check which information that you want to send out for monitoring. The Test check-box is used to verify if setting is working. 6 Web RAID Management Software - Event The Event tab will open the Event View interface. Event View logs all RAID related activity including administrative actions, warnings and hardware failures. HighPoint Technologies Inc. 34
35 There are three options to operate this event log section Clear: Next: Download: Click Clear to remove all current entries from the Event View log. The Event View log can span several pages. Click Next to view past entries. The Event View log can be saved as a text file for reference. 7 Web RAID Management Software - SHI (Storage Health Inspector) Storage Health Inspector: HDD Temperature Threshold: SMART: Schedule SHI will inspect each HDD periodically. If any abnormal status is found, it will be recorded in the Event log. SHI can help to identify problems with HDD s and prevent further damage or data loss. If additional proof of errors is needed, the HDD s can be placed onto the onboard SATA/SAS port and a 3rd party SMART software utility can be run. Setup the HDD temperature threshold to prevent HDD overheating. When the HDD goes beyond the threshold an alert will be triggered. SMART attributes for each HDD will be displayed. The following diagram display detail SMART information read out from HDD This allows user to schedule a task to run HighPoint Technologies Inc. 35
36 When schedule button is checked, it displays the following configuration page to schedule a task to run. Task List: The Task tab allows you to schedule maintenance sessions for RAID 1, 5, 6, 10 and 50 arrays. User can name each task and specify the frequency, date, hour, minute and second for each session. Regular maintenance is highly recommended for any redundant RAID array, and is essential for maintaining healthy, reliable storage configurations. HighPoint Technologies Inc. 36
37 8 Web RAID Management Software - Recover Recover can help repair RAID arrays that have been assigned the disabled status. This feature helps protect RAID configurations by storing multiple copies of RAID configuration data, which administrators can use to restore a disabled RAID array. Note: Please refer the How-To guide that explains this Recover feature: HighPoint Technologies Inc. 37
38 APPENDIX B - Web RAID Management ICON Definition List The following table lists the definition of each ICON used by the RAID Management interface (The examples use a RAID 5 array for reference). Icon Description The array status is "Normal". The array has stopped Initializing. Current status is Uninitialized. The array is Initializing : Initializing (Foreground) and Initializing (Background). The array is performing a data consistency checking and its current status is Verifying. The array status is "Critical" - a disk is missing from the RAID array. The array status is "Verifying". This indicates that the array is running a data integrity check. The array status is "Rebuilding". This occurs when the data verification fails or when adding a new disk into the "Critical" array. The array status is "Critical". This indicates that current array needs "rebuild". This icon will also show up on a device in a RAID disk member as needing to "rebuild" its data. The status of the "Array" or "Device" is "Disabled". The array is "Initializing". There are two types of initialization- Foreground and Background. The array OCE/ORLM operation has stopped. This icon means the RAID array is "Uninitialized". On the RAID array either Foreground or Background initialization has stopped (Incomplete). On a disk ( ), it indicates that the disk is not initialized and will need to be initialized for the 1 st time before it can be used with HighPoint RAID card. The device status "Legacy". An existing file system has been created HighPoint Technologies Inc. 38
39 on the HDD. The device is a "Spare". It is used to replace the failed RAID disk member to rebuild automatically. Information. Warning. Error. The array is inconsistent and it needs to rebuild. The current status is Critical. Array disk member diagram is listed below. It shows a RAID-5 disk member is lost and its current status is Critical. Array disk member diagram is listed below. The array is rebuilding and its current status is Rebuilding. Array disk member diagram is listed below. The array is not available. Two scenarios can cause this to happen. First - a lost RAID disk member exceed the minimum required to maintain a RAID level. Second - a disk failed before the initialization or HighPoint Technologies Inc. 39
40 rebuilding process complete. The status is in Disabled. Array disk member diagram is like this: APPENDIX C - RAID Technology Explanation Type Description Mini. disks Usable space JBOD Just a 1 100% Each drive can be bunch of accessed as a single disk volume RAID 1 RAID 0 RAID 10 RAID 5 RAID 50 RAID 6 Disk Mirroring Disk Striping Disk Mirroring followed by stripe Disk Striping with Rotating parity RAID5 set followed by stripe Disk Striping with dual rotating parity Advantage Disadvantage Application 2 50% It provides convenient low-cost data redundancy for smaller systems and servers 2 100% Offers the highest performance 4 50% High read performance and medium write performance with data protection for up to 2-drive failures % High read performance, and medium write performance with data protection with a single drive failure % High read performance, and medium write performance with data protection with a single drive failure % High read performance, and medium write performance with data protection in case of up to two drives failure No fault tolerance - failure of one drive results in complete data loss Useable storage space is 50% of total available capacity No fault tolerance failure of one drive in the array results in complete data lose Useable storage capacity equals total capacity of all drives in the array minus two Not recommended for database applications that require frequent/heavy write sessions. Cost is high because minimum disks requirement is 6 Not recommended for applications that require frequent/heavy write sessions. Backup Operating system, backup, and transaction database. Temporary file, performance driven application. Fast database and application servers which need performance and data protection Data archives, and ideal for application that require data protection Large database, file server, application servers Data archives and ideal for application that requires data protection HighPoint Technologies Inc. 40
41 APPENDIX D - Thunderbolt Daisy Chain configuration Thunderbolt s Daisy Chain feature can connect the host system with 6 Thunderbolt devices (or 5 devices and 1 display). Configuration 1: Connect the host with 6 Thunderbolt Devices. Configuration 2: Connect the host with 5 Thunderbolt devices and one display. HighPoint Technologies Inc. 41
RocketStor 6328 Thunderbolt 2 RAID Host Adapters User s Guide for Mac
RocketStor 6328 Thunderbolt 2 RAID Host Adapters User s Guide for Mac Revision: 1.00 Mar. 12, 2014 HighPoint Technologies, Inc. 1 Table of Contents 1. HighPoint RocketStor 6328.3 2. System Requirement
More informationRocketRAID 644L / 642L
淘汰 RocketRAID 644L / 642L 6Gb/s esata PCI-Express 2.0 RAID HBA For Mac User s Guide Revision: 1.0 Nov. 24, 2012 HighPoint Technologies, Inc. 1 Copyright Copyright 2012 HighPoint Technologies, Inc. This
More informationRocketRAID For Mac User s Guide. SATA 6Gb/s PCI-Express 2.0 x 8 RAID HBA. Revision: 1.00 Jun. 26, 2013 HighPoint Technologies, Inc.
淘汰 RocketRAID 3600 SATA 6Gb/s PCI-Express 2.0 x 8 RAID HBA For Mac User s Guide Revision: 1.00 Jun. 26, 2013 HighPoint Technologies, Inc. 1 Copyright Copyright 2013 HighPoint Technologies, Inc. This document
More informationSSD7110 Hybrid Connectivity M.2 + SAS/SATA Ports, All-in one RAID Controller. User Guide V1.01
SSD7110 Hybrid Connectivity M.2 + SAS/SATA Ports, All-in one RAID Controller User Guide V1.01 1 Table of Contents System Requirements... 3 SSD7101A Hardware... 3 NVMe Drive Installation:... 4 Setting up
More informationRocketU 1144CM Host Controller
RocketU 1144CM Host Controller 4-Port USB 3.0 PCI-Express 2.0 x4 RAID HBA for Mac User s Guide Revision: 1.0 Dec. 13, 2012 HighPoint Technologies, Inc. 1 Copyright Copyright 2013 HighPoint Technologies,
More informationRocketStor 6314A User Manual
RocketStor 6314A User Manual Sept. 25, 2015 Revision v1.02 HighPoint Technologies, Inc. 1 Copyright Copyright 2015HighPointTechnologies, Inc. This document contains materials protected by International
More informationRocketStor 6674T. User Manual. November 14 th, 2017 Revision HighPoint Technologies, Inc.
RocketStor 6674T User Manual November 14 th, 2017 Revision 1.0.0 HighPoint Technologies, Inc. 1 Copyright Copyright 2017 HighPoint Technologies, Inc. This document contains materials protected by International
More informationrdrive 6114VM User Manual 12/6/17 Revision HighPoint Technologies, Inc.
rdrive 6114VM User Manual 12/6/17 Revision 1.0.0 HighPoint Technologies, Inc. 1 Copyright Copyright 2017 HighPoint Technologies, Inc. This document contains materials protected by International Copyright
More informationRocketU 1144BM Host Controller
RocketU 1144BM Host Controller USB 3.0 Host Adapters for Mac User s Guide Revision: 1.0 Oct. 22, 2012 HighPoint Technologies, Inc. 1 Copyright Copyright 2012 HighPoint Technologies, Inc. This document
More informationHigh Density RocketRAID EJ6172 Device Board Data RAID Installation Guide
High Density RocketRAID 2711 + EJ6172 Device Board Data RAID Installation Guide Introduction The HighPoint High Density Storage Solutions hammer down high density storage cost over a single mini- SAS port.
More informationrdrive 6628AW User Manual 1/17/18 Revision HighPoint Technologies, Inc.
rdrive 6628AW User Manual 1/17/18 Revision 1.0.3 HighPoint Technologies, Inc. 1 Copyright Copyright 2018 HighPoint Technologies, Inc. This document contains materials protected by International Copyright
More informationG-SPEED Product Guide
G-SPEED Product Guide G-Technology Inc. Tel: (310) 449-4599 Fax: (310) 449-4670 support@g-technology.com TABLE OF CONTENTS 1. INTRODUCTION 2. SAFETY PRECAUTIONS 3. SYSTEM REQUIREMENTS 4. WHAT S IN THE
More informationrdrive 6114VW User Manual 12/6/17 Revision HighPoint Technologies, Inc.
rdrive 6114VW User Manual 12/6/17 Revision 1.0.0 HighPoint Technologies, Inc. 1 Copyright Copyright 2017 HighPoint Technologies, Inc. This document contains materials protected by International Copyright
More informationHigh Density RocketRAID Rocket EJ240 Device Board Data RAID Installation Guide
High Density RocketRAID 2711 + Rocket EJ240 Device Board Data RAID Installation Guide Introduction The HighPoint High Density Storage Solutions hammer down high density storage cost over a single mini-
More informationRocketStor 6114V. User Manual. May 2, 2017 Revision 1.00 HighPoint Technologies, Inc.
RocketStor 6114V User Manual May 2, 2017 Revision 1.00 HighPoint Technologies, Inc. 1 Copyright Copyright 2017 HighPoint Technologies, Inc. This document contains materials protected by International Copyright
More informationHighPoint NA381TB3. 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion. User Manual
HighPoint NA381TB3 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion User Manual First edition, June. 2017 1. Overview 3 2. Package Checklist 3 3. Panel Layout 4 4. Hardware Configuration
More informationRocketRAID 2840A. SAS 6Gb/s PCI-Express 3.0 x8 RAID Controller. User s Guide v1.0
RocketRAID 2840A SAS 6Gb/s PCI-Express 3.0 x8 RAID Controller User s Guide v1.0 1 Table of Contents 1. HighPoint RocketRAID 2840A Overview... 3 2. Board Layout & Hardware Installation... 4 3. Using the
More informationRocketRAID 3600 Series
RocketRAID 3600 Series SATA 6Gb/s PCI-Express 2.0 x 8 RAID HBA User s Guide Revision: 1.01 Jun. 23, 2015 HighPoint Technologies, Inc. 1 Copyright Copyright 2013 HighPoint Technologies, Inc. This document
More informationSSD Bay U.2 NVMe RAID Enclosure. User Guide V1.00
SSD6540 4-Bay U.2 NVMe RAID Enclosure User Guide V1.00 1 Kit Contents 1x 4-Bay Tower Enclosure 1x PCIe 3.0 x16 RAID Controller 4x Drive Trays 2x HD mini-sas cable (1 meter) 1x UL Power Cord 16x 2.5 SSD
More informationSAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1
SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying
More informationIntroduction...1. Package Contents... 1 Product Features... 1 Specifications Product Schematic...2. HDD Installation...3
1 Table of Contents Introduction...1 Package Contents... 1 Product Features... 1 Specifications... 1 Product Schematic...2 HDD Installation...3 Connecting to your Computer...6 Connecting to Mac...7 Connecting
More informationFIVE-BAY RAID SYSTEM FOR 3.5 SATA HARD-DISK DRIVES
DRD-501 FIVE-BAY RAID SYSTEM FOR 3.5 SATA HARD-DISK DRIVES USER MANUAL Thank you for choosing Xcellon. The Xcellon DRD-501 Five-Bay RAID System is a convenient solution for large-data storage needs, housing
More informationTaurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.inxtron.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
More informationSAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2
SAS to SAS/SATA JBOD Subsystem Revision 1.2 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Subsystem... 6 1.4 Identifying Parts
More informationTaurus Mini Super-S3. Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.1
Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.1 EN Table of Contents Table of Contents 1 Introduction... 1 1.1 System Requirements... 1 1.1.1 PC
More informationSAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1
SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying
More informationMAXPower esata 6G-4e PCIe 2.0 Controller Card
MAXPower esata 6G-4e PCIe 2.0 Controller Card USER GUIDE TABLE OF CONTENTS 1.1 ABOUT THIS MANUAL 1 1.2 PACKAGE CONTENTS 1 1.3 SYSTEM REQUIREMENTS 1 2.1 RAID MODES 2 2.2 HARDWARE INSTALLATION 2 2.3 SOFTWARE
More informationHydra Super-S LCM. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 30, v1.2
4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 30, 2009 - v1.2 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM
More informationTaurus Mini Super-S LCM
Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives User Manual August 1, 2011 v1.0 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 System Requirements...
More informationTaurus Super-S LCM. Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives. User Manual July 27, v1.2
Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives User Manual July 27, 2009 - v1.2 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III
More informationG-RAID 2 Installation Guide
G-RAID 2 Installation Guide TABLE OF CONTENTS 1. INTRODUCTION 2. SAFETY PRECAUTIONS 3. SYSTEM REQUIREMENTS 4. WHAT S IN THE BOX 5. G-RAID2 OVERVIEW 6. INSTALLING G-RAID2 7. INITIALIZING G-RAID2 7.1 Mac
More informationNA381TB3. 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion. User Manual
NA381TB3 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion User Manual First edition, June. 2017 1. Overview 3 2. Package Checklist 3 3. Panel Layout 4 4. Hardware Configuration 5 5. Building
More informationNAS System. User s Manual. Revision 1.0
User s Manual Revision 1.0 Before You Begin efore going through with this manual, you should read and focus on the following safety guidelines. Information about the NAS system s packaging and delivery
More informationMD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0
4-Bay Rack Mount Chassis User Manual February 6, 2009 - v1.0 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM esata equipped
More informationRocketRAID 600L. User s Guide. SATA 6Gb/s PCI-Express 2.0 RAID Host Adapters. Revision: 1.0 Nov. 19, 2012 HighPoint Technologies, Inc.
RocketRAID 600L SATA 6Gb/s PCI-Express 2.0 RAID Host Adapters User s Guide Revision: 1.0 Nov. 19, 2012 HighPoint Technologies, Inc. 1 Copyright Copyright 2012 HighPoint Technologies, Inc. This document
More informationUSB 3.1 Type-C Gen 2 Dual-Bay External SATA SSD Enclosure Model
USB 3.1 Type-C Gen 2 Dual-Bay External SATA SSD Enclosure Model 201080 User Manual (Available in a PDF file) support@cablematters.com Table of Contents 1. INTRODUCTION... 1 1.1 Introduction 1.2 Copyright
More informationTOWERSTOR TS25CT. QUICK INSTALLATION GUIDE v1.0
TOWERSTOR TS25CT QUICK INSTALLATION GUIDE v1.0 Contents Preface... 2 Before You Begin... 3 Chapter 1 Introduction... 4 1.1 Technical Specification... 4 1.2 Identifying Parts of the RAID Subsystem...5 1.2.1
More informationRocketRAID 2840A. SAS 6Gb/s PCI-Express 3.0 x8 RAID Controller. Quick Installation Guide v1.0
RocketRAID 2840A SAS 6Gb/s PCI-Express 3.0 x8 RAID Controller Quick Installation Guide v1.0 1 Table of Contents HighPoint RocketRAID 2840A... 3 Kit Contents... 3 Board Layout... 4 Hardware Installation...
More informationConfiguration Tool and Utilities v3.25 Operation Manual. for Fusion RAID Storage Systems
Configuration Tool and Utilities v3.25 Operation Manual for Fusion RAID Storage Systems Contents 1.0 ATTO Configuration Tool Overview... 1 About the Configuration Tool Configuration Tool Launch Configuration
More informationUSB 3.1 Type-C Gen 2 Dual-Bay External M.2 NGFF SATA Enclosure Model
USB 3.1 Type-C Gen 2 Dual-Bay External M.2 NGFF SATA Enclosure Model 201078 User Manual (Available in a PDF file) support@cablematters.com Table of Contents 1. INTRODUCTION... 1 1.1 Introduction 1.2 Copyright
More informationRAIDTech USER S MANUAL. Revised October 3, Features
RAIDTech USER S MANUAL Revised October 3, 2006 Features Simple, hardware-based RAID (levels 0 or 1) On-the-fly data protection: RAID 1 makes backing up as painless as possible. The data is mirrored in
More informationFirst Edition, July 2011
First Edition, July 2011 Copyright Netstor Technology Co., Ltd. All rights reserved Table of contents 1. Introduction P1 2. Configuration via GUI 2.1 Starting the RAID Manager P1 2.1.1 For Windows operating
More informationSAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0
SAS to SAS/SATA JBOD Subsystem Revision 1.0 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Terminologies... 6 Chapter 2 Getting Started... 7 2.1 Unpacking
More informationNT2 U3. 2-Bay RAID Storage Enclosure. User Manual May 18, 2010 v1.1
2-Bay RAID Storage Enclosure User Manual May 18, 2010 v1.1 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM Windows Vista, Windows
More informationDrobo 5D3 User Guide
Drobo 5D3 User Guide 1 Drobo 5D3 User Guide... 6 2 Before You Begin... 7 2.1 Product Features at a Glance... 7 2.2 Checking Box Contents... 8 2.3 Checking System Requirements... 9 2.3.1 Operating Systems
More informationProduct Release Notes
Product Release Notes ATTO Configuration Tool v3.38 - Windows 1. General Release Information The ATTO Configuration Tool helps you customize the settings of your ATTO storage Controller to maximize the
More informationRocketRAID 2720C2. User Manual V1.00
RocketRAID 2720C2 User Manual V1.00 Nov. 6, 2013 1 Table of contents 1. HighPoint RocketRAID 2720C2 -Cross-Synch Storage Solution... 3 2. Kit Contents... 3 3. Installing the RocketRAID 2720C2 Host Adapters...
More informationDual/Quad 3.5 SATA to USB 3.0 & esata External Hard Drive RAID/Non-RAID Enclosure w/fan. User s Manual
Dual/Quad 3.5 SATA to USB 3.0 & esata External Hard Drive RAID/Non-RAID Enclosure w/fan User s Manual Package Contents: NextStar HX4/HX4R NextStar HX2R 1 2 1 2 3 4 3 4 5 6 5 6 7 1 NexStar HX4R/HX4 2 USB
More informationRocketRAID Series Data RAID Set Up Guide
RocketRAID Series Data RAID Set Up Guide Products: RocketRAID 4522 and 4520 RocketRAID RocketRAID 3740A and 840A 2760A RocketRAID 2740 and 2744 RocketRAID 2722, 2721 and 2711 Revision: v1.0.1 January 30
More information1 Drobo 8D User Guide Before You Begin Product Features at a Glance Checking Box Contents... 9
Drobo 8D User Guide 1 Drobo 8D User Guide... 6 1.1 Before You Begin... 7 1.1.1 Product Features at a Glance... 8 1.1.2 Checking Box Contents... 9 1.1.3 Checking System Requirements... 10 1.1.3.1 Operating
More informationXL-RAID-213SA User Manual
XL-RAID-213SA User Manual Introduction English Thank you for purchasing our products. This manual will introduce the XL-RAID-213SA Series. Before using your XL-RAID-213SA, please read this manual thoroughly.
More informationSOHOTANK ST4-TB User Manual
SOHOTANK ST4-TB User Manual Introduction SOHOTANK ST4-TB User Manual Thank you for purchasing STARDOM products. This manual will introduce the ST4 Series. Before using your ST4, please read this manual
More informationDrobo B810n Getting Started Guide
Drobo B810n Getting Started Guide Table of Contents 1: Before You Begin... 4 1.1 Product features at a glance... 4 1.2 Checking box contents... 5 1.3 Checking system requirements... 5 1.4 Checking hardware
More informationPROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL
PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL Copyright 2002, Promise Technology, Inc. Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be reproduced or transmitted
More informationRocketRAID esata For Mac HighPoint Technologies, Inc.
RocketRAID esata For Mac HighPoint Technologies, Inc. Version 1.1 Copyright 2009 HighPoint Technologies, Inc. All Right Reserved Last Updated on August 2009 Page 1 Table of Contents 1. About RocketRAID
More informationA12S2-PS. Quick Start Guide. August, 2012 V.1.4
A12S2-PS August, 2012 V.1.4 Revision Sheet Release No. Date Revision Description V.1.1 2012/4/10 Initial creation. V.1.2 2012/8/22 Piuture correct on P.3, P.4, P.7, P.11, Modify some wording on P.5, P.10,
More informationRocketRAID 231x/230x SATAII Host Adapter
RocketRAID 231x/230x SATAII Host Adapter User s Guide Revision: 1.4 Date: November 2007 HighPoint Technologies, Inc. Copyright Copyright 2007 HighPoint Technologies, Inc. This document contains materials
More informationA+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e. Chapter 6 Supporting Hard Drives
A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e Chapter 6 Supporting Hard Drives Objectives Learn about the technologies used inside a hard drive and how data is organized on the drive
More informationInfoSafe esata/usb 2.0 Dual 3.5 SATA Drive Enclosure with RAID
InfoSafe esata/usb 2.0 Dual 3.5 SATA Drive Enclosure with RAID SAT3520U2ER SAT3520UERGB FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital
More informationAtlas S8+ Product Manual. Version Promise Technology, Inc. All Rights Reserved.
Atlas S8+ Product Manual Version 1.0 2018 Promise Technology, Inc. All Rights Reserved. Promise Technology Atlas S8+ Copyright 2018 PROMISE Technology, Inc. All Rights Reserved. Important data protection
More informationThe Industry s First Thunderbolt 2 Hardware RAID Adapter
RocketStor 6328 Dual Thunderbolt 20Gb/s to 8x 6Gb/s SAS/SATA Hardware RAID Adapter The Industry s First Thunderbolt 2 Hardware RAID Adapter Industry s First Thunderbolt 2 RAID Adapter HighPoint s palm-sized
More informationRocketRAID 464. User, s Manual. Revision: 1.0 Date: Jun HighPoint Technologies, Inc.
RocketRAID 464 User, s Manual Revision: 1.0 Date: Jun. 2004 HighPoint Technologies, Inc. Copyright Copyright 2004 HighPoint Technologies, Inc. This document contains materials protected by International
More informationRocketRAID 231x SATAII Host Adapter
RocketRAID 231x SATAII Host Adapter User s Guide Revision: 1.2 Date: April 2007 HighPoint Technologies, Inc. Copyright Copyright 2007 HighPoint Technologies, Inc. This document contains materials protected
More information3. Specifications I Features System Requirements Creating A New Partition / Formatting The Hard Drive RAID Mode Selection...
MANUAL Table of Contents: 1. Introduction...1 2. Package Contents...2 3. Specifications I Features...3 4. System Requirements...4 5. Interface Information...5 6. Installation...6 7.Driver Installation...9
More informationSAS JBOD Installation Reference Guide Revision 1.0
SAS JBOD 16-bay Rackmount Enclosure Installation Reference Guide Revision 1.0 P/N: PW0020000000281 Copyright No part of this publication may be reproduced, stored in a retrieval system, or transmitted
More informationRocketRAID 2760A. 6Gb/s SAS/SATA Host Adapter. Quick Instal l ation Guide v1.1
RocketRAID 2760A 6Gb/s SAS/SATA Host Adapter Quick Instal l ation Guide v1.1 Contents HighPoint RocketRAID 2760A PCI-Express 2.0 x16... 3 Hardware Installation... 4 Kit Contents... 4 Installing the RR2760A
More informationapple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.
apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May 2004 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc.
More informationapple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.
apple Service Source Xserve RAID 17 March 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc. All rights reserved. Overview Xserve RAID
More informationTaurus S2. User Manual. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. (English )
Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives User Manual (English ) v1.1 April 23, 2008 EN Table of Contents CHAPTER 1 - INTRODUCTION 1 CHAPTER 3 - SYSTEM SET UP 7 ICON KEY 1 THE TAURUS S2
More informationThe Industry s First Thunderbolt 2 Hardware RAID Adapter
Thunderbolt Storage Solutions RocketStor 6328 Dual Thunderbolt 20Gb/s to 8x 6Gb/s SAS/SATA Hardware RAID Adapter The Industry s First Thunderbolt 2 Hardware RAID Adapter Industry s First Thunderbolt 2
More informationLenovo RAID Introduction Reference Information
Lenovo RAID Introduction Reference Information Using a Redundant Array of Independent Disks (RAID) to store data remains one of the most common and cost-efficient methods to increase server's storage performance,
More informationSSD7101A-1. 4x M.2 Port to PCIe 3.0 x16 NVMe RAID Controller. User Guide V1.00
SSD7101A-1 4x M.2 Port to PCIe 3.0 x16 NVMe RAID Controller User Guide V1.00 1 Table of Contents SSD7101A-1 Overview...3 Kit Contents...3 System Requirements...4 SSD7101A-1 Hardware...5 Setting up the
More informationDrobo 5N2 User Guide
Drobo 5N2 User Guide Contents 1 Drobo 5N2 User Guide... 6 1.1 Before You Begin... 7 1.1.1 Product Features at a Glance... 8 1.1.2 Checking Box Contents...10 1.1.3 Checking System Requirements...11 1.1.3.1
More informationManaging Storage Adapters
This chapter includes the following sections: Self Encrypting Drives (Full Disk Encryption), page 2 Create Virtual Drive from Unused Physical Drives, page 3 Create Virtual Drive from an Existing Drive
More informationOwner s s Manual. SATA A II LCD Hot-Swap Systems. Macintosh, Windows, Linux EXTERNAL SYSTEM INTERNAL 5.25 SYSTEM DUAL EXTERNAL SYSTEM
Owner s s Manual SATA A II LCD Hot-Swap Systems EXTERNAL SYSTEM INTERNAL 5.25 SYSTEM DUAL EXTERNAL SYSTEM Macintosh, Windows, Linux SATA (Serial ATA) Hot-Swap Drive System / Case Kit Table of Contents
More informationThunderbolt TM LTO. mtape
Thunderbolt TM LTO mtape 1 You are now the proud owner of the world s first certified Thunderbolt LTO tape drive! mtape revolutionizes LTO, empowering users to easily connect LTO technology to portable,
More informationYour Data Security Guardian. SafeTANK GR5630-WSB3+ User Manual. v.1.0 (Oct, 2012)
SafeTANK GR5630-WSB3+ User Manual v..0 (Oct, 202) Table of Contents Chapter. Package Contents and Product Views Chapter 2. Environmental Requirements Chapter 3. Hardware Requirements and Precautions Chapter
More informationRocketRAID mini-sas 6G HBA Series Data RAID. Installation Guide
RocketRAID mini-sas 6G HBA Series Data RAID Installation Guide Overview: This installation guide provides step and step instructions on how to configure the RocketRAID mini-sas 6G storage to support a
More informationSATA Hard Drive Enclosure
S252U2ERR Instruction Manual SATA Hard Drive Enclosure 2.5 Black esata and USB to Dual Removable SATA Hard Drive Enclosure with RAID FCC Compliance Statement This equipment has been tested and found to
More informationModel: DS-2250J. Venus T5 mini 2.5 SATA RAID. User Manual.
Venus T5 mini 2.5 SATA RAID User Manual www.amselectronics.com 1 Contents 1. Features...3 2. DIP Switch and RAID Mode cross reference...5 2.1 RAID 0 for High Performance...7 2.2 RAID 1 (Mirror) for High
More informationRocketRAID 2322 SATAII Host Adapter
RocketRAID 2322 SATAII Host Adapter User s Guide Revision: 1.0 Date: January 2006 HighPoint Technologies, Inc. Copyright Copyright 2006 HighPoint Technologies, Inc. This document contains materials protected
More informationRocketRAID 272x/271x Host Adapter
RocketRAID 272x/271x Host Adapter Quick Installation Guide V2.2 1 Content HighPoint RocketRAID 272x/271x Series PCI-Express 2.0... 3 Kit Contents... 3 Installing the RocketRAID Series Host Adapter... 4
More informationRocketRAID Intelli-VRM (Intelligent Virtual RAID Management) Early Warning System and Virtual System Rescue
RocketRAID Intelli-VRM (Intelligent Virtual RAID Management) Early Warning System and Virtual System Rescue Introduction The fast-paced, high-definition requirements of our modern, digital age, has increased
More informationAMD RAID Installation Guide
AMD RAID Installation Guide 1. AMD BIOS RAID Installation Guide.. 3 1.1 Introduction to RAID.. 3 1.2 RAID Configurations Precautions 4 1.3 Installing Windows 8 / 8 64-bit / 7 / 7 64-bit / Vista / Vista
More informationDual-Bay 2.5 to 3.5 SATA Hard Drive Adapter Enclosure with RAID
Dual-Bay 2.5 to 3.5 SATA Hard Drive Adapter Enclosure with RAID Product ID: 35SAT225S3R This unique dual-bay adapter enclosure gives you an easy and cost-effective way to upgrade legacy systems such as
More informationNA611TB3. Thunderbolt 3 NVMe SSD Storage. User Manual
NA611TB3 Thunderbolt 3 NVMe SSD Storage User Manual First edition, Nov. 2017 1. Unpack the NA611TB3 3 2. Install M.2 NVMe SSD 4 2.1 Configuration Options 2.2 Pre-Steps for M.2 SSD Module Installation 2.3
More informationRAID Rack (RR2035RPHMS)
RAID Rack (RR2035RPHMS) www.addonics.com Technical Support If you need any assistance to get your unit functioning properly, please have your product information ready and contact Addonics Technical Support
More informationRocketRAID 2700 Series
RocketRAID 2700 Series PCI-E 2.0 x8/x16 6Gb/s SAS/SATA RAID HBA s The Industry s Most Cost-Effective, Comprehensive Selection of SAS/SATA 6Gb/s RAID HBA s HighPoint RocketRAID 2700 HBA s are the most diverse,
More informationTaurus Super-S Combo
Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives User Manual May 11, 2009 - v1.1 EN Table of Contents CHAPTER 1 - INTRODUCTION 1 CHAPTER 3 - SYSTEM SET UP 7 ICON KEY 1 THE TAURUS SUPER-S COMBO
More informationFUSION QR. User s Guide. 4-Drive Hardware RAID 5 SATA Storage System with Quad Interface. For Windows
FUSION QR 4-Drive Hardware RAID 5 SATA Storage System with Quad Interface User s Guide For Windows Contents 1 Fusion QR Features 1 2 Enclosure Setup; Access Drives and Mode Switch 2 Connect the Fusion
More informationRocketRAID 2700 Series
RocketRAID 2700 Series PCI-E 2.0 x8/x16 6Gb/s SAS/SATA RAID HBA s The Industry s Most Cost-Effective, Comprehensive Selection of SAS/SATA 6Gb/s RAID HBA s HighPoint RocketRAID 2700 HBA s are the most diverse,
More informationSATA II HDD Canister KISS DA 435 Quick Reference Guide
SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...
More informationPROMISE ARRAY MANAGEMENT ( PAM) FOR FastTrak S150 TX2plus, S150 TX4 and TX4000. User Manual. Version 1.3
PROMISE ARRAY MANAGEMENT ( PAM) FOR FastTrak S150 TX2plus, S150 TX4 and TX4000 User Manual Version 1.3 Promise Array Management Copyright 2003 Promise Technology, Inc. All Rights Reserved. Copyright by
More informationSOHORAID Series. SR2611 Series. Manual. Two Bays RAID 1 Internal Module
SOHORAID Series SR611 Series Manual Two Bays RAID 1 Internal Module Your Data Security Guardian SOHORAID Series w w w. s t a r d o m. c o m. t w SR611-S-S1 Quick Installation Guide SOHORAID Series Version:1.0
More informationFUSION R400 RAID USB 3.0
FUSION R400 RAID USB 3.0 1U Rackmount 4-Drive Hardware RAID 5 SATA Storage System with USB 3.0 Interface User s Guide For Windows Contents 1 Fusion R400 RAID USB 3.0 Features 1 2 Drive Installation and
More informationCONTENT. English. Overview 1-3. Self- Assembly 4-5. Setup Initialization References BAY RAID ENCLOSURE.
4-BAY RAID ENCLOSURE Model: QB-35RFEU3 English CONTENT Overview 1-3 Self- Assembly 4-5 Setup 6-14 RAID Modus Einstellungen / LED Anzeigen Initialization 15-24 Windows Vista / Windows 7 / Macintosh O.S.
More informationMini-EPICa USB 3.0-to-SATA II RAID SUBSYSTEM
Mini-EPICa USB 3.0-to-SATA II RAID SUBSYSTEM Revision 1.0 Contents Preface... 3 Before You Begin... 4 Chapter 1 Introduction... 6 1.1 Technical Specification... 7 1.2 Identifying Parts of the RAID Subsystem...
More informationInTANK Series ir2620-2s-s2 / SR2611-2S-S2R User Manual
InTANK Series ir2620-2s-s2 / SR26-2S-S2R User Manual ir2620-2s-s2 SR26-2S-S2R v.2.2 (Jun, 20) Index Chapter Check Package Contents and Accessories... Chapter 2 Hardware Introduction... Chapter Precaution
More informationGT 062 3TB Quickstart Addendum
GT 062 3TB Quickstart Addendum NOTE: This document is an addendum to the GT 062 manual, and is intended for the GT 062 3TB model only. 610028 GT 062 3TB Quickstart Addendum.pdf June 17, 2009 The GT 062
More informationFiT RAID SUBSYSTEM. User s Manual V1.0
FiT RAID SUBSYSTEM User s Manual V1.0 Contents Chapter 1 Introduction to FiT RAID subsystem 4 Overview 4 Features & Specification 4 External RAID Subsystems 4 Inner RAID Cages 5 Safety Precautions 5 System
More information