1 I/O-SYSTEM/Interface Modules New Items: Spring 20 N 3/4

2 The new items in this catalog supplement products found in the following main catalogs N 3/4 Volume 4 Interface Modules Volume 3 I/O-SYSTEM

3 Contents I/O-SYSTEM Volume Interface Modules Volume Tools and Accessories 06 Item Number Index 2 3

4 Contents AUTOMATION Fieldbus Couplers, Programmable Fieldbus Controllers, 750 Series ETHERNET Fieldbus Coupler 4 5 ETHERNET Programmable Fieldbus Controller 6 7 ETHERNET Programmable Fieldbus Controller 8 9 Media Redundancy ETHERNET Programmable Fieldbus Controller 0 EtherCAT Fieldbus Coupler 2 3 Linux Programmable Fieldbus Controller, RS I/O-Modules, 750, 753 Series 6-Channel Digital Input Module DC, high-side switching 6 8-Channel Digital Input Module DC, high-side switching, 2-conductor connection 7 8-Channel Digital Input Module DC, high-side switching, 2-conductor connection 8 8-Channel Digital Input Module DC, low-side switching, 2-conductor connection 9 4-Channel Digital Input Module DC, high-side switching, 3-conductor connection 20 4-Channel Digital Input Module DC, high-side switching, 3-conductor connection 2 4-Channel Digital Input Module DC, low-side switching, 3-conductor connection 22 8-Channel Digital Output Module DC, high-side switching, 2-conductor connection 23 8-Channel Digital Output Module DC, low-side switching, 2-conductor connection 24 Field Side Connection Module 6, DC 25 Field Side Connection Module 6-, DC 26 Field Side Connection Module 8/8-, DC / 27 Serial Interface RS-232 / RS-485, configurable/t 28 WAGO AS-Interface Master M4 V Channel Digital Input Safety Module PROFIsafe V2 ipar 32 8-Channel Digital Input Safety Module PROFIsafe V2 ipar 33 4/4-Channel Digital Input and Output Safety Module PROFIsafe V2 ipar 34 4-Channel Digital Input and -Channel Digital Output Safety Module PROFIsafe V2 ipar 35 Filter Module, for field side power supply 36 Filter Module, for system and field side power supply 37 WAGO USB Communication Cable 38 Wireless Technology, 758 Series Bluetooth ETHERNET Gateway 39 Telecontrol Technology, 76 Series TO-PASS Compact 40 Compact, 2 AI 4 Compact, Web 42 Compact, 2 AI, Web 43 TO-PASS Compact 44 Compact, 8 AI, ELog, DLog 45 Compact, 8 AI, Web, MODBUS 46 TO-PASS Mobile, 4 AI 47 Mobile, 4 AI, Web, MODBUS 48 Accessories for Telecontrol Modules 49 Modular I/O-SYSTEM IP67, 767 Series Digital Input/Output Module DC / 0.5 A 8 inputs/outputs (8 x M8) 50 5 Digital Input/Output Module DC / 0.5 A 8 inputs/outputs (4 x M2, two outputs per connector) Accessories S-BUS cable suitable for drag chains (system bus cable), 54 assembled on one end S-BUS cable suitable for drag chains (system bus cable), 55 assembled on both ends and unassembled

5 Relays and Optocouplers, 857 Series JUMPFLEX Relays 56 JUMPFLEX Optocouplers WAGO Ribbon Cables 60 6 Relays, 788 Series Sockets with Miniature Switching Relay Interface Modules in DIN-Rail Mountable Enclosure, 789 Series Relay with Make Contact ( a), Manual-0-Automatic Switch with Monitoring Contact 64 Relay with Changeover Contact ( u), Manual-0-Automatic Switch with Switch Position Monitoring 65 Interface Module RS-232/SMI in DIN-Rail Mountable Enclosure, 23 AC 66 Interface Module RS-232/SMI LoVo in DIN-Rail Mountable Enclosure, DC 67 Current Sensor with Bus Connection in DIN-Rail Mountable Enclosure, Measuring range A WINSTA,770 Series WINSTA Sunblind Box 70 7 Transducers, 857 Series JUMPFLEX Universal Isolation Amplifier JUMPFLEX Isolation Amplifiers, Fixed Setting for Voltage or Current Signals JUMPFLEX Ni Transducer for Ni 00, Ni 20, Ni 200, Ni 500, Ni JUMPFLEX KTY Transducer JUMPFLEX Supply and Through Module 80 8 JUMPFLEX Frequency Transducer JUMPFLEX Current Transducer Power Supplies, 787 Series EPSITRON COMPACT Power Supply, 23 AC / 2 V DC, 2 A 88 EPSITRON COMPACT Power Supply, 23 AC / 2 V DC, 4 A 89 EPSITRON COMPACT Power Supply, 23 AC / DC,.3 A 90 EPSITRON COMPACT Power Supply, 23 AC / DC, 2.5 A 9 EPSITRON COMPACT Power Supply, 23 AC / DC, 4 A 92 EPSITRON PRO Power Supply, 23 AC / 2 V DC, 6 A 93 EPSITRON PRO Power Supply, 23 AC / 2 V DC, 0 A 94 EPSITRON PRO Power Supply, 23 AC / 2 V DC, 5 A 95 EPSITRON PRO Power Supply, 23 AC / DC, 3 A 96 EPSITRON PRO Power Supply, 23 AC / DC, 20 A 97 EPSITRON PRO Power Supply, 23 AC / 48 V DC, 5 A 98 EPSITRON PRO Power Supply, 23 AC / 48 V DC, 0 A 99 EPSITRON PRO Power Supply, 40 AC / 48 V DC, 0 A 00 EPSITRON PRO Power Supply, 40 AC / 48 V DC, 20 A 0 EPSITRON Lead Gel Battery Modules 02 EPSITRON Redundancy Module 03 EPSITRON Wall Mounting Adapter 04 Accessories Mobile Printer, Flatbed Plotter Crimping Tools, Uninsulated Ferrules Test and Measurement Tools 0 Products highlighted in RED are new items for Spring 20

6 ETHERNET Fieldbus Coupler 0/00 Mbit/s; digital and analog signals I/O-SYSTEM Address Supply 8 ON 24V X3 0V ON : WBM 255: DHCP ETHERNET W LINK ACT LINK ACT 2 MS NS I/O Marking area Status indication -Fieldbus -Fieldbus node Data contacts Fieldbus connection RJ-45 X Fieldbus connection RJ-45 X2 Configuration and programming interface (with cover open) The ETHERNET Fieldbus Coupler connects ETHERNET to the modular WAGO-I/O-SYSTEM. The fieldbus coupler automatically configures, creating a local process image which may include analog, digital or specialty modules. Analog and specialty module data is sent via words and/or bytes; digital data is sent bit by bit. Two ETHERNET interfaces and an integrated switch allow the fieldbus to be wired in a line topology. This eliminates additional network devices such as switches or hubs. Both interfaces support Auto-Negotiation and Auto-MDI(X). The DIP switch configures the last byte of the IP address and may be used for IP address assignment (DHCP, BootP, static). The coupler is designed for fieldbus communication in both Ethernet/IP and MODBUS networks. It also supports a wide variety of standard ETHERNET protocols (e.g., HTTP, BootP, DHCP, DNS, SNMP, FTP). An integrated Web server provides configuration and status information to the coupler. The coupler has an integrated supply terminal for the system voltage. The field power jumper contacts are supplied via a separate supply module. Description ETHERNET Coupler System Data No. of couplers connected to Master limited by ETHERNET specification Transmission medium Twisted Pair S-UTP 00 Ω, Cat 5; Max. line length: 00 m Baud rate 0/00 Mbit/s Transmission performance Class D acc. to EN 5073 Buscoupler connection 2 x RJ-45 Protocols EtherNet/IP, MODBUS/TCP (UDP), HTTP, BootP, DHCP, DNS, FTP, SNMP Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Approvals Conformity marking r UL 508 Shipbuilding GL (Germanischer Lloyd)

7 5 0 nf DC DC I/O modules I/O-SYSTEM FIELDBUS INTERFACE ELECTRONICS 0 nf ELECTRONICS FIELDBUS INTERFACE Number of I/O modules 64 with bus extension 250 Fieldbus Max. input process image 020 words Max. output process image 020 words Configuration via PC Voltage supply DC (-25 % %) Input current typ. at rated load () 280 ma Efficiency of the power supply (typ.) at nominal load () 90 % Internal current consumption (5 V) 450 ma Total current for I/O modules (5 V) 700 ma Isolation 50 system/supply General Specifications Operating temperature 0 C C Wire connection CAGE CLAMP Cross sections 0.08 mm²....5 mm² / AWG Stripped lengths mm / 0.22 in Dimensions (mm) W x H x L 50 x 65 x 97 Height from upper-edge of DIN 35 rail Weight 0 g Storage temperature -25 C C Relative air humidity (no condensation) 95 % Vibration resistance acc. to IEC Shock resistance acc. to IEC Degree of protection IP20 EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) EMC: marine applications - immunity to interference acc. to Germanischer Lloyd (2003) EMC: marine applications - emission of interference acc. to Germanischer Lloyd (2003)

8 , / ETHERNET Programmable Fieldbus Controller 0/00 Mbit/s; digital and analog signals I/O-SYSTEM Address Fieldbus connection RJ-45 Fieldbus connection RJ-45 8 ON X X2 ON : WBM 255: DHCP ETHERNET W LINK ACT LINK ACT 2 MS NS I/O USR SD A B V 0V C D Marking area Status voltage supply -System -Power jumper contacts Data contacts Supply Supply via power jumper contacts Configuration and programming interface (with cover open) Power jumper contacts In conjunction with the WAGO-I/O-SYSTEM, the ETHERNET controller can be used as a programmable controller within ETHERNET networks. The fieldbus controller supports all digital, analog and specialty modules found within the 750/753 Series, and is suitable for data rates of 0/00 Mbit/s. Two ETHERNET interfaces and an integrated switch allow the fieldbus to be wired in a line topology. This eliminates additional network devices such as switches or hubs. Both interfaces support Auto-Negotiation and Auto-MDI(X). The DIP switch configures the last byte of the IP address and may be used for IP address assignment. The fieldbus controller supports both MODBUS/TCP and EtherNet/IP for use in industrial environments. It also supports a wide variety of standard ETHERNET protocols for easy integration into IT environments (e.g., HTTP, BootP, DHCP, DNS, SNTP, SNMP, FTP). An integrated Web server provides configuration options and status information from the controller. The device, which is programmable to IEC 63-3, is capable of multitasking and has a battery-backed, real-time clock. Mbyte of data memory is available. The controller has a slot for a removable memory card, allowing, for example, device parameters, boot files or other types of files to be transferred from one controller to another. The memory card can be accessed via FTP and be used as an additional drive. The SD-Card / is specified for industrial applications under harsh environmental conditions and for the use with the Controller. Description ETHERNET Controller ETHERNET Controller/T / Operating temperature -20 C C Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section SD memory card / System Data No. of controllers connected to Master limited by ETHERNET specification Transmission medium Twisted Pair S-UTP 00 Ω, Cat 5; Max. line length: 00 m Baud rate 0/00 Mbit/s Transmission performance Class D acc. to EN 5073 Buscoupler connection 2 x RJ-45 Protocols EtherNet/IP, MODBUS/TCP (UDP), HTTP, BootP, DHCP, DNS, SNTP, FTP, SNMP Programming WAGO-I/O-PRO CAA IEC 63-3 IL, LD, FBD, ST, FC SD card slot Push-push mechanism, sealable cover lid Type of memory card SD and SDHC up to 8 Gbytes (All guaranteed properties are only valid in combination with the WAGO / memory card.) Approvals Conformity marking r UL 508 Shipbuilding pending

9 7 5 / 0 nf DC DC I/O modules I/O-SYSTEM FIELDBUS INTERFACE ELECTRONICS nf ELECTRONICS FIELDBUS INTERFACE Number of I/O modules 64 with bus extension 250 Fieldbus Max. input process image 020 words Max. output process image 020 words Configuration via PC Program memory 024 Kbytes Data memory 024 Kbytes Non-volatile memory (retain) 32 Kbytes Voltage supply DC (-25 % %) Input current typ. at rated load () 500 ma Efficiency of the power supply (typ.) at nominal load () 90 % Internal current consumption (5 V) 450 ma Total current for I/O modules (5 V) 700 ma Isolation 50 system/supply General Specifications Operating temperature 0 C C Wire connection CAGE CLAMP Cross sections 0.08 mm² mm² / AWG Stripped lengths mm / 0.33 in Dimensions (mm) W x H x L 62 x 65 x 00 Height from upper-edge of DIN 35 rail Weight 64 g Storage temperature -25 C C Relative air humidity (no condensation) 95 % Vibration resistance acc. to IEC Shock resistance acc. to IEC Degree of protection IP20 EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) EMC: marine applications - immunity to interference acc. to Germanischer Lloyd (2003) EMC: marine applications - emission of interference acc. to Germanischer Lloyd (2003)

10 ETHERNET Programmable Fieldbus Controller 0/00 Mbit/s; digital and analog signals I/O-SYSTEM Address 8 ON ON : WBM 255: DHCP ETHERNET W LINK ACT LINK ACT 2 MS NS I/O USR A B V 0V C D Marking area Status voltage supply -System -Power jumer contacts Data contacts Supply Supply via power jumper contacts Fieldbus connection RJ-45 X Fieldbus connection RJ-45 X2 Configuration and programming interface (with cover open) Power jumper contacts The ETHERNET Fieldbus Controller connects ETHERNET to the modular WAGO-I/O-SYSTEM. The fieldbus controller automatically configures, creating a local process image which may include analog, digital or specialty modules. Analog and specialty module data is sent via words and/or bytes; digital data is sent bit by bit. Two ETHERNET interfaces and an integrated switch allow the fieldbus to be wired in a line topology. This eliminates additional network devices such as switches or hubs. Both interfaces support Auto-Negotiation and Auto-MDI(X). The DIP switch configures the last byte of the IP address and may be used for IP address assignment (DHCP, BootP, static). The controller is designed for fieldbus communication in both Ethernet/IP and MODBUS networks. It also supports a wide variety of standard ETHERNET protocols (e.g., HTTP, BootP, DHCP, DNS, SNTP, SNMP, FTP). An integrated Web server provides configuration and status information from the controller. The device, which is programmable to IEC63-3, is capable of multitasking and has a real-time clock. Description ETHERNET Controller System Data No. of controllers connected to Master limited by ETHERNET specification Transmission medium Twisted Pair S-UTP 00 Ω, Cat 5; Max. line length: 00 m Baud rate 0/00 Mbit/s Transmission performance Class D acc. to EN 5073 Buscoupler connection 2 x RJ-45 Protocols EtherNet/IP, MODBUS/TCP (UDP), HTTP, BootP, DHCP, DNS, SNTP, FTP, SNMP Programming WAGO-I/O-PRO CAA IEC 63-3 IL, LD, FBD, ST, FC Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Approvals Conformity marking r UL 508 Shipbuilding GL (Germanischer Lloyd)

11 9 5 / 0 nf DC DC I/O modules I/O-SYSTEM FIELDBUS INTERFACE ELECTRONICS nf ELECTRONICS FIELDBUS INTERFACE Number of I/O modules 64 with bus extension 250 Fieldbus Max. input process image 020 words Max. output process image 020 words Configuration via PC Program memory 024 Kbytes Data memory 52 Kbytes Non-volatile memory (retain) 32 Kbytes Voltage supply DC (-25 % %) Input current typ. at rated load () 500 ma Efficiency of the power supply (typ.) at nominal load () 90 % Internal current consumption (5 V) 450 ma Total current for I/O modules (5 V) 700 ma Isolation 50 system/supply General Specifications Operating temperature 0 C C Wire connection CAGE CLAMP Cross sections 0.08 mm² mm² / AWG Stripped lengths mm / 0.33 in Dimensions (mm) W x H x L 62 x 65 x 00 Height from upper-edge of DIN 35 rail Weight 60 g Storage temperature -25 C C Relative air humidity (no condensation) 95 % Vibration resistance acc. to IEC Shock resistance acc. to IEC Degree of protection IP20 EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) EMC: marine applications - immunity to interference acc. to Germanischer Lloyd (2003) EMC: marine applications - emission of interference acc. to Germanischer Lloyd (2003)

12 Media Redundancy ETHERNET Programmable Fieldbus Controller 0/00 Mbit/s; digital and analog signals I/O-SYSTEM Address Fieldbus connection RJ-45 Fieldbus connection RJ-45 8 ON X X2 ON : WBM 255: DHCP ETHERNET MR W LINK ACT LINK ACT 2 MS NS I/O USR A B V 0V C D Marking area Status voltage supply -System -Power jumper contacts Data contacts Supply Supply via power jumper contacts Configuration and programming interface (with cover open) Power jumper contacts In conjunction with the WAGO-I/O-SYSTEM, the Programmable Fieldbus Controller can be used in ETHERNET networks requiring fast and safe media redundancy. The controller supports all digital, analog and specialty modules found within the 750/753 Series, and is suitable for data rates of 0/00 Mbit/s. Media redundancy is achieved by operating the fieldbus controller in two separate networks, in which it is accessible via two different IP addresses (including two MAC IDs). Cross communication between separate channels is not possible. The two separate ETHERNET interfaces allow redundant connection of two transmission paths (no hub or switch required). Both interfaces support Auto-Negotiation and Auto-MDI(X). The DIP switch configures the last byte of both default IP address and may be used for IP address assignment (DHCP, BootP). The media redundancy controller is designed for fieldbus communication via both MODBUS and ETHERNET networks. It also supports a wide variety of standard ETHERNET protocols (e.g., HTTP, BootP, DHCP, DNS, FTP). An integrated Web server provides configuration options and status information from the fieldbus controller. Description Media Redundancy ETHERNET Controller Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section System Data No. of controllers connected to Master limited by ETHERNET specification Transmission medium Twisted Pair S-UTP 00 Ω, Cat 5; Max. line length: 00 m Baud rate 0/00 Mbit/s Transmission performance Class D acc. to EN 5073 Buscoupler connection 2 x RJ-45 Protocols MODBUS/TCP (UDP), HTTP, BootP, DHCP, DNS, FTP Programming WAGO-I/O-PRO CAA IEC 63-3 IL, LD, FBD, ST, FC Redundancy function via two logically separated ETHERNET interfaces Approvals Conformity marking r UL 508 Shipbuilding GL (Germanischer Lloyd)

13 5 / 0 nf DC DC I/O modules I/O-SYSTEM FIELDBUS INTERFACE ELECTRONICS nf ELECTRONICS FIELDBUS INTERFACE Number of I/O modules 64 with bus extension 250 Fieldbus Max. input process image 020 words Max. output process image 020 words Configuration via PC Program memory 024 Kbytes Data memory 52 Kbytes Non-volatile memory (retain) 32 Kbytes Voltage supply DC (-25 % %) Input current typ. at rated load () 500 ma Efficiency of the power supply (typ.) at nominal load () 90 % Internal current consumption (5 V) 450 ma Total current for I/O modules (5 V) 700 ma Isolation 50 system/supply General Specifications Operating temperature 0 C C Wire connection CAGE CLAMP Cross sections 0.08 mm² mm² / AWG Stripped lengths mm / 0.33 in Dimensions (mm) W x H x L 62 x 65 x 00 Height from upper-edge of DIN 35 rail Weight 60 g Storage temperature -25 C C Relative air humidity (no condensation) 95 % Vibration resistance acc. to IEC Shock resistance acc. to IEC Degree of protection IP20 EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) EMC: marine applications - immunity to interference acc. to Germanischer Lloyd (2003) EMC: marine applications - emission of interference acc. to Germanischer Lloyd (2003)

14 EtherCAT Fieldbus Coupler 00 Mbit/s; digital and analog signals Marking area I/O-SYSTEM Supply 24V X3 0V EtherCAT W L/A IN L/A OUT RUN ERR I/O Status indication -Fieldbus -Fieldbus node Data contacts Fieldbus connection RJ-45 Fieldbus connection RJ-45 X I N X 2 O UT Configuration and programming interface (with cover open) The EtherCAT Fieldbus Coupler connects EtherCAT (i.e., the real-time ETHERNET technology) to the modular WAGO-I/O-SYSTEM. The fieldbus controller automatically configures, creating a local process image which may include analog, digital or specialty modules. Analog and specialty module data is sent via words and/or bytes; digital data is sent bit by bit. The upper EtherCAT interface connects the coupler to the network. The lower RJ-45 socket may connect additional EtherCAT devices to the same line. EtherCAT (Ethernet Control Automation Technology) is a real-time ETHERNET solution designed for industrial automation applications and characterized by high performance, flexible topology and simple configuration. With EtherCAT, the costly ETHERNET star topology can be replaced with a simple line or tree structure. EtherCAT is regristered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. Description EtherCAT Coupler System Data No. of couplers connected to Master limited by EtherCAT specification Transmission medium Twisted Pair 2 x 2 or 4 x 2; AWG 26/7 to AWG 22/; SF/FTP, SF/UTP or S/FTP; 00 Ω, Cat 5; Max. line length: 00 m Baud rate 00 Mbit/s Transmission performance Class D acc. to EN Buscoupler connection 2 x RJ-45 Protocols EtherCAT (direct mode) Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Approvals Conformity marking r UL 508

15 3 0 nf DC DC I/O modules I/O-SYSTEM FIELDBUS INTERFACE ELECTRONICS 0 nf ELECTRONICS FIELDBUS INTERFACE Number of I/O modules Fieldbus Max. input process image 024 bytes Max. output process image 024 bytes Configuration via PC Voltage supply DC (-25 % %) Input current typ. at rated load () 250 ma Efficiency of the power supply (typ.) at nominal load () 85 % Internal current consumption (5 V) 300 ma Total current for I/O modules (5 V) 700 ma Isolation 50 system/supply General Specifications Operating temperature 0 C C Wire connection CAGE CLAMP Cross sections 0.08 mm²....5 mm² / AWG Stripped lengths mm / 0.22 in Dimensions (mm) W x H x L 65 x 50 x 97 Height from upper-edge of DIN 35 rail Weight 00 g Storage temperature -25 C C Relative air humidity (no condensation) 95 % Vibration resistance acc. to IEC Shock resistance acc. to IEC Degree of protection IP20 EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007)

16 Linux Programmable Fieldbus Controller, RS-232 ETHERNET 0/00 Mbit/s; digital and analog signals I/O-SYSTEM Fieldbus connection RJ-45 LINUX LINK ACT STATUS SERVICE USR I/O USR 2 A B V 0V C D Status voltage supply -System -Power jumer contacts Data contacts Supply Supply via power jumper contacts Fieldbus connection RS-232 W Configuration and programming interface (with cover open) Power jumper contacts With the Linux ETHERNET Controller, a platform is now available for a high-level language software running on an open operating system. The Linux operating system (kernel version 2.6), is tailor-made for the embedded controller, providing efficient software development as known from PC applications. Free availability of Linux source code and a license-free operating system are the major advantages of the Linux operating system. The Linux ETHERNET Controller is suitable for a wide range of applications currently using specialty hardware or small PC systems. The controller has a battery-backed, real-time clock and 32-bit multitasking CPU. The integrated RS-232 interface communicates with external devices. Software development is also commonly performed in a Linux environment and supported by illustrative examples. Support: Owing to the complexity of the open Linux ETHERNET Controller and WAGO-I/O-IPC, the large number of application options and potential error sources, WAGO can only provide hardware support for these versions. Users must contact our product partners for software support if required, which may incur additional charges. Description Linux ETHERNET Controller, RS System Data System data ETHERNET: No. of controllers connected to Master limited by ETHERNET specification Transmission medium Twisted Pair S-UTP 00 Ω Cat. 5 Max. length of fieldbus segment 00 m between hub station and ; max. length of network limited by ETHERNET specification Baud rate 0/00 Mbit/s Buscoupler connection RJ-45 Protocols MODBUS/TCP, HTTP, BootP, DHCP, FTP Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Linux Controller Distribution CD System data Serial: Transmission medium Max. length of fieldbus segment Baud rate Buscoupler connection Shielded Cu cable 2 (4) x 0.25 mm² 5 m depending on baud rate/cable (at 9,200 baud) 9,600 baud... 5,200 baud x D-Sub 9; socket Approvals Conformity marking r UL 508

17 5 5 / 0 nf DC DC I/O modules I/O-SYSTEM FIELDBUS INTERFACE ELECTRONICS nf ELECTRONICS FIELDBUS INTERFACE Number of I/O modules 64 with bus extension 250 Fieldbus Max. input process image 2 Kbytes Max. output process image 2 Kbytes CPU 32-Bit-Risc ARM7TDMI RAM memory 6 Mbyte SDRAM, 32 Kbyte NOVRAM Flash 8 Mbytes EEPROM 4 Kbytes Operating system Linux (Kernel version 2.6) Voltage supply DC (-5 % %) Max. input current () 500 ma Efficiency of the power supply 87 % Internal current consumption (5 V) 300 ma Total current for I/O modules (5 V) 700 ma Isolation 50 system/supply Voltage via power jumper contacts DC (-5 % %) Current via power jumper contacts (max.) 0 A DC General Specifications Operating temperature 0 C C Wire connection CAGE CLAMP Cross sections 0.08 mm² mm² / AWG Stripped lengths mm / 0.33 in Dimensions (mm) W x H x L 5 x 65 x 00 Height from upper-edge of DIN 35 rail Weight 200 g Storage temperature -25 C C Relative air humidity (no condensation) 95 % Vibration resistance acc. to IEC Shock resistance acc. to IEC Degree of protection IP20 EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007)

18 Channel Digital Input Module DC High-side switching I/O-SYSTEM Status DI... DI Data contacts CAGE CLAMP S connection DI DI 6 DI DI 3 DI 5 DI 7 DI 9 DI DI 2 DI 4 DI 6 DI 8 DI 0 DI 2 DI 0nF DI 0nF DI DI 4 DI DI 6 Power jumper contacts The digital input module provides 6 channels at a width of just 2mm (0.47in). It receives binary control signals from digital field devices (e.g., sensors, encoders, switches or proximity switches). CAGE CLAMP S terminations provide direct insertion of solid conductors. Each input channel has a noise-rejection RC filter with a 0.2ms time constant. A green LED indicates the switched status of each channel. An optocoupler provides electrical isolation between the bus and the field side operating tool (2.5mm blade) is required to open the CAGE CLAMP S. Description 6DI 24V DC 0.2ms Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Operating tool, with partially insulated shaft, type, blade (2.5 x 0.4) mm Number of inputs 6 Current consumption (internal) 25 ma Voltage via power jumper contacts DC (-25 % %) Signal voltage (0) -3 V... 5 V DC Signal voltage () 5 V... 3 DC Input filter 0.2 ms Input current (typ.) 0.6 ma (at -3 V... 5 V DC) 2. ma ma (at 5 V...32 V DC) Isolation 50 system/field Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm²....5 mm² / AWG fine-stranded: 0.25 mm²....5 mm² / AWG Stripped lengths mm / 0.33 in Width 2 mm Weight 50 g Approvals 750 Series Conformity marking

19 Channel Digital Input Module DC High-side switching, 2-conductor connection Status DI... DI 8 CAGE CLAMP S connection DI DI Data contacts DI DI 2 DI 3 DI 4 DI 5 DI DI 0nF DI 0nF I/O-SYSTEM DI DI Power jumper contacts The digital input module provides 8 channels in 2-wire connection at a width of just 2mm (0.47in). It receives binary control signals from digital field devices (e.g., sensors, encoders, switches or proximity switches). CAGE CLAMP S terminations provide direct insertion of solid conductors. Each input channel has a noise-rejection RC filter with a 3.0ms time constant. A green LED indicates the switched status of each channel. An optocoupler provides electrical isolation between the bus and the field side operating tool (2.5mm blade) is required to open the CAGE CLAMP S. Description 8DI 24V DC 3.0ms, 2-conductor Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Operating tool, with partially insulated shaft, type, blade (2.5 x 0.4) mm Number of inputs 8 Current consumption (internal) 6 ma Current consumption typ. (field side) 2 ma Voltage via power jumper contacts DC (-25 % %) Signal voltage (0) -3 V... 5 V DC (Type /3) Signal voltage () V... 3 DC (Type 3) Input filter 3.0 ms Input current (typ.).6 ma (at -3 V... 5 V DC) 4.3 ma ma (at V V) Isolation 50 system/field Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm²....5 mm² / AWG fine-stranded: 0.25 mm²....5 mm² / AWG Stripped lengths mm / 0.33 in Width 2 mm Weight 50 g Approvals 750 Series Conformity marking r UL 508 Shipbuilding GL (Germanischer Lloyd)

20 Channel Digital Input Module DC High-side switching, 2-conductor connection I/O-SYSTEM Status DI... DI 8 CAGE CLAMP S connection DI DI Data contacts DI DI 2 DI 3 DI 4 DI 5 DI DI 0nF DI 0nF DI DI Power jumper contacts The digital input module provides 8 channels in in 2-wire connection at a width of just 2mm (0.47in). It receives binary control signals from digital field devices (e.g., sensors, encoders, switches or proximity switches). CAGE CLAMP S terminations provide direct insertion of solid conductors. Each input channel has a noise-rejection RC filter with a 0.2ms time constant. A green LED indicates the switched status of each channel. An optocoupler provides electrical isolation between the bus and the field side operating tool (2.5mm blade) is required to open the CAGE CLAMP S. Description 8DI 24V DC 0.2ms, 2-conductor Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Operating tool, with partially insulated shaft, type, blade (2.5 x 0.4) mm Number of inputs 8 Current consumption (internal) 6 ma Current consumption typ. (field side) 2 ma Voltage via power jumper contacts DC (-25 % %) Signal voltage (0) -3 V... 5 V DC (Type /3) Signal voltage () V... 3 DC (Type 3) Input filter 0.2 ms Input current (typ.).6 ma (at -3 V... 5 V DC) 4.3 ma ma (at V V) Isolation 50 system/field Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm²....5 mm² / AWG fine-stranded: 0.25 mm²....5 mm² / AWG Stripped lengths mm / 0.33 in Width 2 mm Weight 50 g Approvals 750 Series Conformity marking r UL 508 Shipbuilding GL (Germanischer Lloyd)

21 750-47, Channel Digital Input Module DC Low-side switching, 2-conductor connection Status DI... DI 8 CAGE CLAMP S connection DI DI Data contacts DI DI 2 DI 3 DI 4 DI 5 DI DI 0nF 0nF DI 0nF I/O-SYSTEM DI DI Power jumper contacts The digital input module provides 8 channels in 2-wire connection at a width of just 2mm (0.47in). It receives binary control signals from digital field devices (e.g., sensors, encoders, switches or proximity switches). CAGE CLAMP S terminations provide direct insertion of solid conductors. Each input channel has a noise-rejection RC filter with a 3.0/0.2ms time constant. A green LED indicates the switched status of each channel. An optocoupler provides electrical isolation between the bus and the field side operating tool (2.5mm blade) is required to open the CAGE CLAMP S. Description 8DI 24V DC 3.0ms, low-side switching, 2-conductor 8DI 24V DC 0.2ms, low-side switching, 2-conductor Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Operating tool, with partially insulated shaft, type, blade (2.5 x 0.4) mm Number of inputs 8 Current consumption (internal) 2 ma Voltage via power jumper contacts DC (-25 % %) Signal voltage (0) (V V - 5 V DC)... V V Signal voltage () -3 V DC... (V V - 5 V) Input filter 3.0 ms (750-47) 0.2 ms (750-48) Input current (typ.) -0.6 ma (at -3 V... 5 V DC) -2.3 ma ma (at 5 V...32 V DC) Isolation 50 system/field Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm²....5 mm² / AWG fine-stranded: 0.25 mm²....5 mm² / AWG Stripped lengths mm / 0.33 in Width 2 mm Weight 50 g Approvals 750 Series Conformity marking r UL 508 Shipbuilding GL (Germanischer Lloyd)

22 Channel Digital Input Module DC High-side switching, 3-conductor connection Status DI... DI I/O-SYSTEM DI DI 2 Data contacts DI 3 DI 4 Power jumper contacts DI DI DI 3 DI 4 DI 0nF DI 0nF The digital input module provides 4 channels in 3-wire connection at a width of just 2mm (0.47in). It receives binary control signals from digital field devices (e.g., sensors, encoders, switches or proximity switches). CAGE CLAMP S terminations provide direct insertion of solid conductors. Each input channel has a noise-rejection RC filter with a 3.0ms time constant. A green LED indicates the switched status of each channel. An optocoupler provides electrical isolation between the bus and the field side operating tool (2.5mm blade) is required to open the CAGE CLAMP S. Description 4DI 24V DC 3.0ms, 3-conductor Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Operating tool, with partially insulated shaft, type, blade (2.5 x 0.4) mm Number of inputs 4 Current consumption (internal) 4 ma Current consumption typ. (field side) 2 ma Voltage via power jumper contacts DC (-25 % %) Signal voltage (0) -3 V... 5 V DC (Type /3) Signal voltage () V... 3 DC (Type 3) Input filter 3.0 ms Input current (typ.).6 ma (at -3 V... 5 V DC) 4.3 ma ma (at V V) Isolation 50 system/field Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm²....5 mm² / AWG fine-stranded: 0.25 mm²....5 mm² / AWG Stripped lengths mm / 0.33 in Width 2 mm Weight 50 g Approvals 750 Series Conformity marking r UL 508 Shipbuilding GL (Germanischer Lloyd)

23 Channel Digital Input Module DC High-side switching, 3-conductor connection Status DI... DI DI DI 2 Data contacts DI 3 DI 4 Power jumper contacts DI DI DI 3 DI 4 DI 0nF DI 0nF I/O-SYSTEM The digital input module provides 4 channels in 3-wire connection at a width of just 2mm (0.47in). It receives binary control signals from digital field devices (e.g., sensors, encoders, switches or proximity switches). CAGE CLAMP S terminations provide direct insertion of solid conductors. Each input channel has a noise-rejection RC filter with a 0.2ms time constant. A green LED indicates the switched status of each channel. An optocoupler provides electrical isolation between the bus and the field side operating tool (2.5mm blade) is required to open the CAGE CLAMP S. Description 4DI 24V DC 0.2ms, 3-conductor Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Operating tool, with partially insulated shaft, type, blade (2.5 x 0.4) mm Number of inputs 4 Current consumption (internal) 4 ma Current consumption typ. (field side) 2 ma Voltage via power jumper contacts DC (-25 % %) Signal voltage (0) -3 V... 5 V DC (Type /3) Signal voltage () V... 3 DC (Type 3) Input filter 0.2 ms Input current (typ.).6 ma (at -3 V... 5 V DC) 4.3 ma ma (at V V) Isolation 50 system/field Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm²....5 mm² / AWG fine-stranded: 0.25 mm²....5 mm² / AWG Stripped lengths mm / 0.33 in Width 2 mm Weight 50 g Approvals 750 Series Conformity marking r UL 508 Shipbuilding GL (Germanischer Lloyd)

24 , Channel Digital Input Module DC Low-side switching, 3-conductor connection Status DI... DI I/O-SYSTEM DI DI 2 Data contacts DI 3 DI 4 Power jumper contacts DI DI DI 3 DI 4 DI 0nF 0nF DI 0nF The digital input module provides 4 channels in 3-wire connection at a width of just 2mm (0.47in). It receives binary control signals from digital field devices (e.g., sensors, encoders, switches or proximity switches). CAGE CLAMP S terminations provide direct insertion of solid conductors. Each input channel has a noise-rejection RC filter with a 3.0/0.2ms time constant. A green LED indicates the switched status of each channel. An optocoupler provides electrical isolation between the bus and the field side operating tool (2.5mm blade) is required to open the CAGE CLAMP S. Description 4DI 24V DC 3.0ms, low-side switching, 3-conductor 4DI 24V DC 0.2ms, low-side switching, 3-conductor Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Operating tool, with partially insulated shaft, type, blade (2.5 x 0.4) mm Number of inputs 4 Current consumption (internal) 7 ma Voltage via power jumper contacts DC (-25 % %) Signal voltage (0) (V V - 5 V DC)... V V Signal voltage () -3 V DC... (V V - 5 V) Input filter 3.0 ms ( ) 0.2 ms ( ) Input current (typ.) -0.6 ma (at -3 V... 5 V DC) -2.3 ma ma (at 5 V V DC) Isolation 50 system/field Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm²....5 mm² / AWG fine-stranded: 0.25 mm²....5 mm² / AWG Stripped lengths mm / 0.33 in Width 2 mm Weight 50 g Approvals 750 Series Conformity marking r UL 508 Shipbuilding GL (Germanischer Lloyd)

25 Channel Digital Output Module DC High-side switching, 2-conductor connection Status DO... DO 8 CAGE CLAMP S connection DO DO Data contacts DO DO 2 DO 3 DO 4 DO 5 DO DO 0 nf 270 pf 0 nf DO I/O-SYSTEM DO DO Power jumper contacts The digital output module provides 8 channels in in 2-wire connection at a width of just 2mm (0.47in). It transmits binary control signals from the automation device to connected actuators (e.g., magnetic valves, contactors, transmitters, relays or other electrical loads). CAGE CLAMP S terminations provide direct insertion of solid conductors. A green LED indicates the switched status of each channel. An optocoupler provides electrical isolation between the bus and the field side operating tool (2.5mm blade) is required to open the CAGE CLAMP S. Description 8DO 24V DC 0.5A, 2-conductor Interference-free for use in safety functions (see manual) Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Operating tool, with partially insulated shaft, type, blade (2.5 x 0.4) mm No. of outputs 8 Max. current consumption (internal) 20 ma Voltage via power jumper contacts DC (-25 % %) Type of load resistive, inductive, lamps Max. switching frequency khz Output current (max.) 0.5 A, short-circuit protected Current consumption typ. (field side) 5 ma Isolation 50 system/field Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm²....5 mm² / AWG fine-stranded: 0.25 mm²....5 mm² / AWG Stripped lengths mm / 0.33 in Width 2 mm Weight 50 g Approvals 750 Series Conformity marking r UL 508 Shipbuilding GL (Germanischer Lloyd)

26 Channel Digital Output Module DC Low-side switching, 2-conductor connection I/O-SYSTEM Status DO... DO 8 CAGE CLAMP S connection DO DO Data contacts DO DO 2 DO 3 DO 4 DO 5 DO DO 0 nf 270 pf 0 nf DO DO DO Power jumper contacts The digital output module provides 8 channels in 2-wire connection at a width of just 2mm (0.47in). It transmits binary control signals from the automation device to connected actuators (e.g., magnetic valves, contactors, transmitters, relays or other electrical loads). CAGE CLAMP S terminations provide direct insertion of solid conductors. A green LED indicates the switched status of each channel. An optocoupler provides electrical isolation between the bus and the field side operating tool (2.5mm blade) is required to open the CAGE CLAMP S. Description 8DO 24V DC 0.5A, low-side switching, 2-conductor Interference-free for use in safety functions (see manual) Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Operating tool, with partially insulated shaft, type, blade (2.5 x 0.4) mm No. of outputs 8 Max. current consumption (internal) 20 ma Voltage via power jumper contacts DC (-25 % %) Type of load resistive, inductive, lamps Max. switching frequency khz Output current (max.) 0.5 A, short-circuit protected Current consumption typ. (field side) 8 ma Isolation 50 system/field Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm²....5 mm² / AWG fine-stranded: 0.25 mm²....5 mm² / AWG Stripped lengths mm / 0.33 in Width 2 mm Weight 50 g Approvals 750 Series Conformity marking r UL 508 Shipbuilding GL (Germanischer Lloyd)

27 Field Side Connection Module 6 DC CAGE CLAMP S connection Data contacts I/O-SYSTEM Power jumper contacts The field side connection module provides 24V power for the inputs of the and channel input modules (also suitable for 8 channel input modules in -wire connection), eliminating external terminal blocks operating tool (2.5mm blade) is required to open the CAGE CLAMP S. The 24V supply and 0V potential are derived from the internal power jumper contacts of an adjacent upstream I/O module. A connection of the potentials to the downstream I/O modules is made automatically via the power jumper contacts when snapping the I/O modules together. The 24V power is available to all 6 field side CAGE CLAMP S connections and the 0V potential is passed through without being used by the module. Description Field Side Connection Voltage via power jumper contacts (max.) Current via power jumper contacts (max.) Wire connection Cross sections Stripped lengths Width Weight DC DC0 A CAGE CLAMP S solid: 0.08 mm²....5 mm² / AWG fine-stranded: 0.25 mm²....5 mm² / AWG mm / 0.33 in 2 mm 48.5 g Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Operating tool, with partially insulated shaft, type, blade (2.5 x 0.4) mm Approvals 750 Series Conformity marking r UL 508 Shipbuilding GL (Germanischer Lloyd)

28 Field Side Connection Module 6- DC I/O-SYSTEM CAGE CLAMP S connection Data contacts Power jumper contacts The field side connection module provides 0V potential for the outputs of the 6-channel output module (also suitable for 8 channel output modules in -wire connection), eliminating external terminal blocks operating tool (2.5mm blade) is required to open the CAGE CLAMP S. The 24V supply and 0V potential are derived from the internal power jumper contacts of an adjacent upstream I/O module. A connection of the potentials to the downstream I/O modules is made automatically via the power jumper contacts when snapping the I/O modules together. The 0V potential is available to all 6 field side CAGE CLAMP S connections and the 24V power is passed through without being used by the module. Description Field Side Connection Voltage via power jumper contacts (max.) Current via power jumper contacts (max.) Wire connection Cross sections Stripped lengths Width Weight DC DC0 A CAGE CLAMP S solid: 0.08 mm²....5 mm² / AWG fine-stranded: 0.25 mm²....5 mm² / AWG mm / 0.33 in 2 mm 48.5 g Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Operating tool, with partially insulated shaft, type, blade (2.5 x 0.4) mm Approvals 750 Series Conformity marking r UL 508 Shipbuilding GL (Germanischer Lloyd)

29 Field Side Connection Module 8/8- / DC CAGE CLAMP S connection Data contacts CAGE CLAMP S connection I/O-SYSTEM Power jumper contacts The field side connection module provides and power for the inputs and outputs of the 8-channel input/output module (also suitable for 8-channel I/O modules, -wire connection) eliminating external terminal blocks. The 24V supply and 0V potential are derived from the internal power jumper contacts of an adjacent upstream I/O module. A connection of the potentials to the downstream I/O modules is made automatically via the power jumper contacts when snapping the I/O modules together. The and power is available to all eight filed side CAGE CLAMP S connections operating tool (2.5mm blade) is required to open the CAGE CLAMP S. Description Field Side Connection 8/ Voltage via power jumper contacts (max.) DC Current via power jumper contacts (max.) DC0 A Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm²....5 mm² / AWG fine-stranded: 0.25 mm²....5 mm² / AWG Stripped lengths mm / 0.33 in Width 2 mm Weight 48.5 g Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Operating tool, with partially insulated shaft, type, blade (2.5 x 0.4) mm Approvals 750 Series Conformity marking r UL 508 Shipbuilding GL (Germanischer Lloyd)

30 Serial Interface RS-232 / RS-485 Configurable I/O-SYSTEM Function Transmission status Reception status Error (buffer full) RTS (RS-232) Z (RS-485/422) 3 4 D0 D D2 D3 RS... enabled Flow control enabled User LED User LED 0 Data contacts TxD (RS-232) Y (RS-485/422) RTS/Z TxD/Y RxD/A CTS/B TxD/Y Logic CTS (RS-232) B (RS-485/422) Common (ground) Shield (screen) M M S S RxD (RS-232) A (RS-485/422) Common (ground) Shield (screen) Power jumper contacts CTS/B Common (ground) Shield (screen) RxD/A RTS/Z Common (ground) Shield (screen) 4 x 270 pf MΩ 0 nf Reception Transmission Operating mode (RS-232/-485) Flow control Function Delivered without miniature WSB markers The serial interface module connects RS-485/422 or RS-232 interface devices to the WAGO-I/O-SYSTEM 750. It also provides gateways between the serial interface and the fieldbus systems supported by the WAGO-I/O-SYSTEM 750. No higher protocol level is required by the module. Communication is completely transparent to the fieldbus master, which provides a wide range of applications for the serial interface module. If required, communication protocols can be configured via fieldbus master. The 2560-byte input buffer provides for high data transmission rates. At lower transmission rates, the data received in lower priority tasks is evaluated without data loss. The 52-byte output buffer provides fast transmission of larger data strings. The module can be configured via WAGO-I/O-CHECK or GSD files. Flexible baud rate and data width selection enable easy adaptation to applications. Compatible with the following couplers/controllers (SW=software): (SW 4), (SW 8 and only for 8-byte mode), (SW 7), (SW 02), (SW 03) and (SW 04) (additional couplers/controllers upon request) Description RS-232 / RS-485 configurable RS-232 / RS-485 configurable/t / (Operating temperature -20 C C) Accessories WAGO-I/O-CHECK, RS-232 kit Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Transmission channels TxD / RxD, full duplex, half duplex 7 or 8 bit data, or 2 stop bit Baud rate 9,600 baud (default setting) 300 baud... 5,200 baud Bit transfer RS-485/-422: ISO 8482 / DIN ; RS-232: EIA/TIA-232-F Line length RS-485/-422: max. approx. 000 m twisted pair, RS-232: max. 40 m Buffer 2560 bytes in / 52 bytes out Current consumption (internal) 85 ma Voltage supply via system voltage DC/DC Isolation 50 system/supply Internal bit width x 46/ x 24/ x 6 bytes in/out (parametrizable), 2 bytes control/status Wire connection CAGE CLAMP Cross sections 0.08 mm² mm² / AWG Stripped lengths mm / 0.33 in Width 2 mm Weight 50 g Approvals 750 Series Conformity marking r UL 508

31 29 I/O-SYSTEM

32 30 WAGO AS-Interface Master I/O-SYSTEM PROFIBUS ETHERNET TCP/IP DeviceNet CANopen PROFIBUS DP WAGO-I/O-SYSTEM NTERFACE Configuration via WAGO-I/O-CHECK for example DI Slaves Digital Input/ Digital Output AI DO AO IP20 IP67 Safety at Work Monitor M Motor Connections Slaves Analog Input/ Analog Output DI DI = Safety at Work Slave AS-Interface Power Supply

33 / WAGO AS-Interface Master Status M NC NC M M2 ASI ASI Data contacts M2 M AS-I M2 AS-i AS-i - AS-i AS-i - M M2 0nF Powerfail Comparator ASI4U Mode Logic I/O-SYSTEM AS-i ASI - ASI - AS-i AS-i 3 7 0nF AS-i - AS-i - AS-i Delivered without miniature WSB markers Power jumper contacts The AS-I Master Module connects AS-Interface systems to a higher-level fieldbus. The module acts as a master for the AS-Interface and as a slave for the fieldbus. The 75x-655 AS-I Master Module is an M4 master per AS-Interface V3.0 Specification. This means: Up to 62 AS-Interface slaves can be connected per AS-I line Analog signal transfer is integrated in the masters Slave profile support complies with V3.0 Combined -5 transaction types and acyclic write/read services are implemented. Description AS-Interface Master M4 V AS-Interface Master M4 V3.0 (without connector) Accessories Approvals 753 Series Coding elements Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section 750 and 753 Series Conformity marking AS-Interface certificate ZU 5060 r UL r ANSI/ISA Class I, Div. 2, Grp. ABCD, T4 750 Series 4 EN I M2 / II 3 GD Ex na IIC T4 Shipbuilding GL, Polski Rejestr Statkov The AS-I functions are provided both cyclically and acyclically via the fieldbus. In cyclic data transfer, up to 32 bytes of I/O data are transferred for the AS-I line binary data. Free cyclic process image areas can be mapped with analog values. Furthermore, analog signals and all other commands and data of the new AS-I specification can be transferred in a management channel via the fieldbus. Diagnostics, which go far beyond the AS-I specifications, simplify the detection of both sporadic configuration errors and AS-I communication interferences. An auto-installation mode allows an AS-Interface network to be created via sequential slave installation, with no addressing tool required. Both signal transmission and operating status, as well as trouble-free internal data bus communication are indicated via LEDs. AS-I specification 3.0 No. of slaves up to 62 Current consumption (AS-I) 40 ma Voltage supply (AS-I) 26.5 V V Max. length of AS-I cable 00 m (300 m through repeater) Cycle time AS-I 0.3 ms... 0 ms, depending on the number of slaves Configuration via process image, WAGO-I/O-CHECK Transmission channel Max. current consumption (internal) 55 ma Voltage supply via system voltage DC/DC Isolation 50 system/supply/as-i Bit width max bytes, configurable including byte control/status Wire connection CAGE CLAMP Cross sections 0.08 mm² mm² / AWG Stripped lengths, 750/753 Series mm / 0.33 in mm / 0.37 in Width 2 mm Weight 56 g EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) EMC: marine applications - immunity to interference acc. to Germanischer Lloyd (2003) EMC: marine applications - emission of interference acc. to Germanischer Lloyd (2003)

34 / ,750-66/ / Channel Digital Input Safety Module PROFIsafe V2 ipar Status LEDs Inputs A B C D E F G H Diagnostic LEDs I/O-SYSTEM Pulse output Pulse output 2 Data contacts Input Input 2 T T2 I I2 T Pulse output X Input 3 T I3 I T2 Pulse output 2 Input 4 T2 I4 I4 Power jumper contacts Fig. 753 Series/Delivered without miniature WSB markers Both / and / PROFIsafe Input Modules connect potential-free, emergency-off switches with contacts, protection door switches, mode selectors, safety sensors and semiconductor outputs. The modules have 4 clock-sensitive inputs (I-I4) fed via 2 differently clocked outputs (T-T2); clock outputs are short-circuit protected. Inputs are continually monitored for cross circuits and voltage supply from separate sources. Additional safety relevant parameters (e.g., operating modes, switching off test pulses, discrepancy or filter times) can be configured via WAGO-I/O-CHECK. The configuration tool can be conveniently integrated into engineering systems supporting both CC2 and CC3 tool calling interfaces (TCI). When exchanging modules, parameters are automatically downloaded into the control unit via PROFIsafe-compatible ipar server -- depending on the settings. The PROFIsafe address can be set using the DIP switch located on the side of the module, or via WAGO-I/O-CHECK. Description 4FDI 24V PROFIsafe V2 ipar / (without connector) 4FDI 24V PROFIsafe V2 ipar / Accessories 753 Series connector Coding elements Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section The modules support both PROFIsafe V (PROFIBUS) and V2 (PROFIBUS, PROFINET) protocols. An optocoupler provides electrical isolation between the bus and the field side. Individual I/O modules can be arranged in any combination when configuring the fieldbus node. To protect the module against surge voltages (over-voltage protection acc. to IEC ), the filter module or an external surge filter must be used to filter the 24V supply voltage. Reference the product manual for further information (available in German and English). Inputs: Sensor inputs I... I4; clock sensitive to T... T2 Type acc. to IEC63 Input current (typ.) 2.2 ma Input frequency (max.) 50 Hz General specifications: Achievable safety classes Cat. 4, SIL 3, PL e Voltage supply 5 V system voltage via internal bus via power jumper contacts Voltage via power jumper contacts DC (20.4 V V) Current consumption typ. (internal) 45 ma Current consumption typ. (field side) 20 ma Wire connection CAGE CLAMP Cross sections 0.08 mm² mm² / AWG Stripped lengths, 750/753 Series mm / 0.33 in mm / 0.37 in Width 2 mm Weight 5 g EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) Standards and Approvals 750 and 753 Series Safety standards IEC 6508; IEC 6206; EN 954-; EN ISO 3849 Conformity marking r UL 508

35 / , / / Channel Digital Input Safety Module PROFIsafe V2 ipar Status LEDs Inputs 3 32 A E B F C G D H I N K O L P M Q Diagnostic LEDs Status LEDs Inputs Pulse output Input Pulse output 2 Input 2 Data contacts Input 5 Pulse output Input 6 Pulse output 2 T, I T2, I2 T, I5 T2, I6 T I/O-SYSTEM Pulse output Input 3 X X 2 Input 7 Pulse output T, I3 T, I7 I T2 Pulse output 2 Input 4 Input 8 Pulse output 2 T2, I4 T2, I8 I8 Power jumper contacts Fig. 753 Series/Delivered without miniature WSB markers Both / and / PROFIsafe Input Modules connect potential-free, emergency-off switches with contacts, protection door switches, mode selectors, safety sensors and semiconductor outputs. The module provides 8 clock sensitive inputs (I-I8) fed via 2 differently clocked outputs (T-T2); clock outputs are short-circuit protected. Inputs are continually monitored for cross circuits and voltage supply from separate sources. Additional safety relevant parameters (e.g., operating modes, switching off test pulses, discrepancy or filter times) can be configured via WAGO-I/O-CHECK. The configuration tool can be conveniently integrated into engineering systems supporting both CC2 and CC3 tool calling interfaces (TCI). When exchanging modules, parameters are automatically downloaded into the control unit via PROFIsafe-compatible ipar -- server, depending on settings. The PROFIsafe address can be set using the DIP switch located on the side of the module, or via WAGO-I/O-CHECK. Description 8FDI 24V PROFIsafe V2 ipar / (without connector) 8FDI 24V PROFIsafe V2 ipar / Accessories 753 Series connector Coding elements Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section The modules support both PROFIsafe V (PROFIBUS) and V2 (PROFIBUS, PROFINET) protocols. An optocoupler provides electrical isolation between the bus and the field side. Individual I/O modules can be arranged in any combination when configuring the fieldbus node. To protect the module against surge voltages (over-voltage protection acc. to IEC ), the filter module or an external surge filter must be used to filter the 24V supply voltage. Reference the product manual for further information (available in German and English). Inputs: Sensor inputs I... I8; clock sensitive to T... T2 Type acc. to IEC63 Input current (typ.) 2.2 ma Input frequency (max.) 50 Hz General specifications: Achievable safety classes Cat. 4, SIL 3, PL e Voltage supply 5 V system voltage via internal bus via power jumper contacts Voltage via power jumper contacts DC (20.4 V V) Current consumption typ. (internal) 48 ma Current consumption typ. (field side) 20 ma Wire connection CAGE CLAMP Cross sections 0.08 mm² mm² / AWG Stripped lengths, 750/753 Series mm / 0.33 in mm / 0.37 in Width 24 mm Weight 90 g EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) Standards and Approvals 750 and 753 Series Safety standards IEC 6508; IEC 6206; EN 954-; EN ISO 3849 Conformity marking r UL 508

36 / , / / /4-Channel Digital Input and Output Safety Module PROFIsafe V2 ipar I/O-SYSTEM Status LEDs Inputs/ Outputs Pulse output Input Pulse output 2 Input A E B F C G D H I N K O L P M Q Diagnostic LEDs Status LEDs Inputs/ Outputs Data contacts Output - Output Output 2- Output 2 T, I T2, I2 O, O- O2, O2- O T Pulse output Input 3 X X 2 Output 3- Output 3 T, I3 O3, O3- O- O4 I T2 Pulse output 2 Input 4 Output 4- Output 4 T2, I4 O4, O4- O4- I4 Power jumper contacts Fig. 753 Series/Delivered without miniature WSB markers Both / and / Modules have 4 power outputs (O-O4), as well as 4 clock-sensitive inputs (I-I4). The sensors can be supplied directly with 24V or fed by 2 differently clocked outputs (T-T2). The inputs connect potential-free, emergency-off switches with contacts, protection door switches, mode selectors, as well as both safety sensors and semiconductor outputs (e.g., light barriers, PLC outputs). The power outputs switch both DC3 resistive and inductive loads with up to a 2A-rated current without requiring any additional external circuit. The power outputs operate in both bipolar (high-side/low-side switching) and unipolar (common potential on one side of the load) modes. The modules monitor short-circuits, cross circuits and 24V voltage supply from separate sources. Both the monitoring and additional safety relevant parameters (e.g., operating modes, switching off test pulses, discrepancy or filter times) can be configured via WAGO-I/O-CHECK. The configuration tool can be conveniently integrated into engineering systems supporting both CC2 and CC3 tool calling interfaces (TCI). Description 4FDI/4FDO 24V/2A PROFIsafe V2 ipar / (without connector) 4FDI/4FDO 24V/2A PROFIsafe V2 ipar / Accessories Standards and Approvals 753 Series connector Coding elements Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section 750 and 753 Series Safety standards IEC 6508; IEC 6206; EN 954-; EN ISO 3849 Conformity marking r UL 508 When exchanging modules, parameters are automatically downloaded into the control unit via PROFIsafe-compatible ipar server -- depending on settings. The PROFIsafe address can be set using the DIP switch on the side of the module, or via WAGO-I/O-CHECK. The module supports both the PROFIsafe V (PROFIBUS) and V2 (PROFIBUS, PROFINET) protocols. The individual input modules can be arranged in any combination when configuring the fieldbus node. To protect the module against surge voltages (over-voltage protection acc. to IEC ), the filter module or an external surge filter must be used to filter the 24V supply voltage. Reference the product manual for further information (available in German and English). Inputs: Sensor inputs I... I4; clock sensitive to T... T2 Type acc. to IEC63 Input current (typ.) 2.2 ma Input frequency (max.) 50 Hz Outputs: Power outputs O... O4; power outputs for actuators Output current (per channel) O... O4: 2 A Total output current 8 A Max. switching frequency Resistive load = 50 Hz; Inductive load = 0. Hz Capacitive load for each channel O... O4; 2.2 μf Test pulse length 0 ms ms General specifications: Achievable safety classes Cat. 4, SIL 3, PL e Voltage supply 5 V system voltage via internal bus via power jumper contacts Voltage via power jumper contacts DC (20.4 V V) Current consumption typ. (internal) 80 ma Current consumption typ. (field side) 20 ma charge Wire connection CAGE CLAMP Cross sections 0.08 mm² mm² / AWG Stripped lengths, 750/753 Series mm / 0.33 in mm / 0.37 in Width 24 mm Weight 00 g EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007)

37 / , / / Channel Digital Input and -Channel Digital Output Safety Module PROFIsafe V2 ipar 24V/0A semiconductor power output 35 Status LEDs Inputs/ Outputs Pulse output Input Pulse output 2 Input A E B F C G D H I N K O L P M Q Diagnostic LEDs Status LEDs Inputs/ Outputs Data contacts O OB T, I T2, I2, OB, O IN OUT /X2. T I T2 I4 I/O-SYSTEM Pulse output Input 3 Pulse output 2 Input 4 X X 2 O- O2A O2B T, I3 T2, I4 O2A, O- O2B OB O2A O2B /X2.5 Power jumper contacts The 75x-666/ module is equipped with 4 power outputs (O... O4) and 4 clock sensitive inputs (I... I4). The sensors can be supplied directly with 24V, or fed by 2 differently clocked outputs (T... T2). The inputs connect potential-free, emergency-off switches with contacts, protection door switches, mode selectors, as well as both safety sensors and semiconductor outputs (e.g., light barriers, PLC outputs). The power outputs switch both DC3 resistive and inductive loads with up to a 2A-rated current without requiring any additional external circuit. The power outputs operate in both bipolar (high-side/low-side switching) and unipolar (common potential on one side of the load) modes. The modules monitor short-circuits, cross circuits and 24V voltage supply from separate sources. Both the monitoring and additional safety relevant parameters (e.g., operating modes, switching off test pulses, discrepancy or filter times) can be configured via WAGO-I/O-CHECK. The configuration tool can be conveniently integrated into engineering systems supporting both CC2 and CC3 tool calling interfaces (TCI). Description 4FDI/FDO 24V/0A PROFIsafe V2 ipar; power safety module with transistor output (without connector) 4FDI/FDO 24V/0A PROFIsafe V2 ipar; power safety module with transistor output / / Accessories 753 Series connector Coding elements Standards and Approvals Miniature WSB Quick marking system unbedruckt with marking see Full Line Catalog 200/20 Volume 3, Section 750 and 753 Series Safety standards IEC 6508; IEC 6206; EN 954-; EN ISO 3849 Conformity marking When exchanging modules, parameters are automatically downloaded into the control unit via PROFIsafe-compatible ipar server -- depending on settings. The PROFIsafe address can be set using the DIP switch on the side of the module, or via WAGO-I/O-CHECK. The modules support both PROFIsafe V (PROFIBUS) and V2 (PROFIBUS, PROFINET) protocols. Individual input modules can be arranged in any combination when configuring the fieldbus node. To protect the module against surge voltages (over-voltage protection acc. to IEC ), the filter module or an external surge filter must be used the 24V supply voltage. Reference the product manual for further information (available in German and English). Inputs: Sensor inputs I... I4; clock sensitive to T... T2 Type acc. to IEC63 Input current (typ.) 2.2 ma Input frequency (max.) 50 Hz Outputs: Power outputs O... O2; power outputs for actuators Output current (per channel) O... O2: 0 A Total output current 0 A Max. switching frequency Resistive load = 50 Hz; Inductive load = 0. Hz Test pulse length 0 ms ms General specifications: Achievable safety classes Cat. 4, SIL 3, PL e Voltage supply 5 V system voltage via internal bus via power jumper contacts Voltage via power jumper contacts DC (20.4 V V) Current consumption typ. (internal) 80 ma Current consumption typ. (field side) 30 ma charge Wire connection CAGE CLAMP Cross sections 0.08 mm² mm² / AWG Stripped lengths, 750/753 Series mm / 0.37 in mm / 0.33 in Width 24mm Weight 00 g EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007)

38 I/O-SYSTEM Filter Module for field side power supply A B 3 4 C D Status voltage supply -Power jumper contacts Data contacts Supply via power jumper contacts Delivered without miniature WSB markers Power jumper contacts The WAGO-I/O-SYSTEM 750 can also be used in shipping industry applications. Suitable onshore and offshore installations are: platforms, loading facilities, cranes, monitor systems for containers, and other onboard systems. This is possible via certification under the standards of leading agencies such as Germanischer Lloyd and Lloyd s Register. Proper system operation is ensured (certified) by using this overvoltage protection module. This module is equipped with surge suppression. Furthermore, version / is streamlined for use in systems with insulation monitoring / Required for shipbuilding certified operation with 750 Series I/O modules Required for shipbuilding certified operation with Ex-i supply module. Required for the use of 750 Series PROFIsafe modules. Description 24V DC Field Side Power Supply Filter with Overvoltage (Surge) Protection, High Isolation 24V DC Field Side Power Supply Filter with Overvoltage (Surge) Protection / Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Voltage via power jumper contacts (max.) DC (-25 % %) Current via power jumper contacts (max.) 0 A DC Wire connection CAGE CLAMP Cross sections 0.08 mm² mm² / AWG Stripped lengths mm / 0.33 in Width 2 mm Weight 5 g EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) EMC: marine applications - immunity to interference acc. to Germanischer Lloyd (2003) EMC: marine applications - emission of interference acc. to Germanischer Lloyd (2003) Approvals 750 Series Conformity marking r UL r ANSI/ISA Class I, Div. 2, Grp. ABCD, T4 4 EN I M2 / II 3 GD Ex na IIC T4 Shipbuilding see Full Line Catalog 200/20 Volume 3, Section

39 Filter Module for system and field side power supply 37 A B 3 4 C D Status voltage supply -System -Power jumper contacts Data contacts System power supply (Out) Supply via power jumper contacts I/O-SYSTEM System power supply (In) Delivered without miniature WSB markers Power jumper contacts The WAGO-I/O-SYSTEM 750 can also be used in shipping industry applications. Suitable onshore and offshore installations are: platforms, loading facilities, cranes, monitor systems for containers, and other onboard systems. This is possible via certification under the standards of leading agencies such as Germanischer Lloyd and Lloyd s Register. Proper system operation is ensured (certified) by using this filter module. The module filters the 24V system power supply and is equipped with surge suppression. Furthermore, version / is streamlined for use in systems with insulation monitoring / Required for shipbuilding certified operation with both 750 Series couplers and programmable controllers Required for shipbuilding certified operation with both 758 Series IPCs and Ex-i supply module. Required for the use of 750 Series PROFIsafe modules. Description 24V DC Power Supply Filter with Overvoltage (Surge) Protection, High Isolation 24V DC Power Supply Filter with Overvoltage (Surge) Protection / Accessories Miniature WSB Quick marking system plain with marking see Full Line Catalog 200/20 Volume 3, Section Voltage via power jumper contacts (max.) DC (-25 % %) Current via power jumper contacts (max.) 0 A DC Current via system voltage (max.) A /.5 A (depending on the version, see manual) Wire connection CAGE CLAMP Cross sections 0.08 mm² mm² / AWG Stripped lengths mm / 0.33 in Width 2 mm Weight 5 g EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) EMC: marine applications - immunity to interference acc. to Germanischer Lloyd (2003) EMC: marine applications - emission of interference acc. to Germanischer Lloyd (2003) Approvals 750 Series Conformity marking r UL r ANSI/ISA Class I, Div. 2, Grp. ABCD, T4 4 EN I M2 / II 3 GD Ex na IIC T4 Shipbuilding see Full Line Catalog 200/20 Volume 3, Section

40 , / WAGO USB Communication Cable I/O-SYSTEM The WAGO USB Communication Cable connects a PC (notebook) to either the service interface of the 857 Series Signal Conditioners and Relay Modules (JUMPFLEX), or to WAGO-I/O-SYSTEM buscouplers/controllers. Notice: Using the WAGO USB Communication Cable in combination with select programmable fieldbus controllers requires the specific firmware versions listed below (or greater): as from firmware version / as from firmware version 2 Description WAGO USB Communication Cable WAGO USB Communication Cable, length 5 m / USB specification 2.0 compatible/full-speed device Operating system Microsoft Windows 2000; Microsoft Windows XP Professional; Microsoft Windows Vista ; Microsoft Windows 7 Operating temperature -25 C C Interface USB Type A/m Length 2.5 m ( ) 5 m ( /000-00) Connector dimensions (WxHxD) 5 x 50 x 9 Test voltage 2.5 kv, 50 Hz, min. EMC: - immunity to interference acc. to EN , EN EMC: - emission of interference acc. to EN Approvals Conformity marking

41 Bluetooth ETHERNET Gateway Wireless transmission link for ETHERNET protocols 2 39 Power connector: M2 plug, A-coded : Vin (DC ) 2: External Trigger Ground 3: Vin GND () 4: External Trigger (DC ) 5: n.c. I/O-SYSTEM ETHERNET connector: M2 socket, D-coded : Transmit 2: Receive 3: Transmit - 4: Receive - The Bluetooth ETHERNET gateway simplifies creation of a wireless transmission link for ETHERNET protocols (e.g., PROFINET, MODBUS/TCP, Ethernet/IP). The gateway is used as a cable substitute to create a robust, industry-proven Bluetooth 2.0 link between two automation devices. The IP65 housing and circularly polarized antenna allow the gateway to be used even in harsh industrial environments. Simple, push-button operation provides very fast connection between two Bluetooth ETHERNET gateways. Additional settings can be made via Web-based management. Bluetooth Adaptive Frequency Hopping (AFH) and Low Emission Mode TM provide excellent coexistence with other wireless systems, such as WLAN. Note: Two Bluetooth ETHERNET gateways are required to establish a point-to-point connection. Description Bluetooth ETHERNET Gateway Accessories IP67 cables and connectors see Full Line Catalog 200/20 I/O-SYSTEM, Sections 6 and 9 Approvals R&TTE (Europe) FCC/CFR 47 part 5 IC (Industry Canada) Conformity marking Wireless technology Bluetooth 2.0 Topology Point-to-point connection Coexistence AFH, Low Emission Mode TM Profiles supported Generic Access Profile (GAP), Personal Area Networking Profile (PANU, NAP) Frequency band License-free ISM band, MHz Transmission range up to 400 m (class ) Antenna Internal, circularly polarized, directional antenna Voltage supply DC Voltage range 9 V... 3 DC Current consumption 46 ma at DC Ports ETHERNET connector: M2 socket, D-coded Power connector: M2 plug, A-coded Configuration Simple, push-button operation and Web-based management Number of inputs (trigger input) Dimensions (mm) W x H x L 66 x 36.2 x 9 Weight approx. 20 g Operating temperature -30 C C Storage temperature -40 C C Degree of protection IP65 EMC: - immunity to interference acc. to EN (2005)

42 TO-PASS Compact Telecontrol module for fault detection/indication, monitoring and remote control I/O-SYSTEM TO-PASS SIM Com Busy Run Status PC < 05 mm/4.2 in > < 09 mm/4.29 in > Compact telecontrol module for fault detection/indication and monitoring of machines and installations over a GSM network. The module can be used in many countries via an integrated quad-band GSM modem. Messages are sent via SMS, , fax or phone call. In addition, the process image can be transmitted in an adjustable cycle to a user-selected Internet address. Switching of outputs is performed via SMS. Special functions: Acknowledgment: Acknowledging any fault message Stand-by: Automatic remote switching of the stand-by service Remote parametrization: Programming and remote control conveniently performed from the office 4 digital inputs, 4 digital outputs and 2 analog inputs with integrated GSM modem. Ideal for applications in distributed stations for temperatures ranging from -20 C to 70 C. Ability to mount on DIN-rail and intuitive user software make unit easy to handle. Operating voltage ranges from 0V to 30VDC. Description TO-PASS Compact 76-0 Accessories Antennas, USB adapter, GSM modem and power supply units Approvals Approvals r UL 508 see page 47 and Full Line Catalog 200/20 Volume 3, Section 3 for all EU countries Approvals for other countries on request Operating temperature -20 C C Type of mounting DIN 35 rail Antenna connection SMA Wire connection Terminal strips (WAGO 250 Series) with push-wire connection Cross sections 0.5 mm²....5 mm² / AWG Stripped lengths 9 mm /0.35 in Dimensions (mm) W x H x L 09 x 05 x 78 Weight 42 g Storage temperature -40 C C Degree of protection IP20 EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) Digital inputs: Number of inputs 4 (Type 3) Input current max. 2.9 ma at 3 DC Signal voltage (0)... 5 V DC Signal voltage () 7 V... 3 DC Digital outputs: No. of outputs 4 contacts Output current (max.) 0.5 A/ 3 DC, short-circuit protected Communication GSM quad-band Communication types SMS (bidirectional), telecommunication dial-up connection (CSD) Signaling 3 LEDs for operating status indication Operating voltage... 3 DC Closed current approx. 20 ma at 24V operating voltage Current during transmission < 500 ma at 24V operating voltage

43 76- TO-PASS Compact, 2 AI Telecontrol module for fault detection/indication, monitoring and remote control 3 4 TO-PASS SIM Com Busy Run Status PC < 05 mm/4.2 in > I/O-SYSTEM < 09 mm/4.29 in > Compact telecontrol module for fault detection/indication and monitoring of machines and installations over a GSM network. The module can be used in many countries via an integrated quad-band GSM modem. Messages are sent via SMS, , fax or phone call. Switching of outputs is performed via SMS. 4 digital inputs, 4 digital outputs and 2 analog inputs with integrated GSM modem. Ideal for applications in distributed stations for temperatures ranging from -20 C to 70 C. Ability to mount on DIN-rail and intuitive user software make unit easy to handle. Operating voltage ranges from 0V to 30VDC. Special functions: Acknowledgment: Acknowledging any fault message Stand-by: Automatic remote switching of the stand-by service Remote parametrization: Programming and remote control conveniently performed from the office Description TO-PASS Compact, 2 AI 76- Accessories Antennas, USB adapter, GSM modem and power supply units Approvals Approvals r UL 508 see page 47 and Full Line Catalog 200/20 Volume 3, Section 3 for all EU countries Approvals for other countries on request Operating temperature -20 C C Type of mounting DIN 35 rail Antenna connection SMA Wire connection Terminal strips (WAGO 250 Series) with push-wire connection Cross sections 0.5 mm²....5 mm² / AWG Stripped lengths 9 mm /0.35 in Dimensions (mm) W x H x L 09 x 05 x 78 Weight 42 g Storage temperature -40 C C Degree of protection IP20 EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) Digital inputs: Number of inputs 4 (Type 3) Input current max. 2.9 ma at 3 DC Signal voltage (0)... 5 V DC Signal voltage () 7 V... 3 DC Analog inputs: Number of inputs 2 (0/4 ma ma) Internal resistance approx. 200 Ω / 20 ma Measuring error (25 C) < ± % of the full scale value Temperature coefficient < ± 0. % / K of the full scale value Digital outputs: No. of outputs 4 contacts Output current (max.) 0.5 A/ 3 DC, short-circuit protected Communication GSM quad-band Communication types SMS (bidirectional), telecommunication dial-up connection (CSD) Signaling 3 LEDs for operating status indication Operating voltage... 3 DC Closed current approx. 20 ma at 24V operating voltage Current during transmission < 500 ma at 24V operating voltage

44 TO-PASS Compact, WEB Telecontrol module for fault detection/indication, monitoring and remote control I/O-SYSTEM TO-PASS SIM Com Busy Run Status PC < 05 mm/4.2 in > < 09 mm/4.29 in > Compact telecontrol module for fault detection/indication and Internet connectivity for machines and installations over a GSM network. The module can be used in many countries via an integrated quad-band GSM modem. Messages are sent via SMS, , fax or phone call. In addition, the process image can be transmitted in an adjustable cycle to a user-selected Internet address. Switching of outputs is performed via SMS. 4 digital inputs and 4 digital outputs with integrated GSM modem. Ideal for applications in distributed stations for temperatures ranging from -20 C to 70 C. Ability to mount on DIN-rail and intuitive user software make unit easy to handle. Operating voltage ranges from 0V to 30VDC. Special functions: Acknowledgment: Acknowledging any fault message Stand-by: Automatic remote switching of the stand-by service Remote parametrization: Programming and process visualization conveniently performed from the office GPRS-dedicated line: Permanent online connection to the process on a WEB server or PC with fixed IP address (e.g., DSL connection) Description TO-PASS Compact, WEB 76-2 Accessories Antennas, USB adapter, GSM modem and power supply units Approvals Approvals r UL 508 see page 47 and Full Line Catalog 200/20 Volume 3, Section 3 for all EU countries Approvals for other countries on request Operating temperature -20 C C Type of mounting DIN 35 rail Antenna connection SMA Wire connection Terminal strips (WAGO 250 Series) with push-wire connection Cross sections 0.5 mm²....5 mm² / AWG Stripped lengths 9 mm /0.35 in Dimensions (mm) W x H x L 09 x 05 x 78 Weight 42 g Storage temperature -40 C C Degree of protection IP20 EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) Digital inputs: Number of inputs 4 (Type 3) Input current max. 2.9 ma at 3 DC Signal voltage (0)... 5 V DC Signal voltage () 7 V... 3 DC Digital outputs: No. of outputs 4 contacts Output current (max.) 0.5 A/ 3 DC, short-circuit protected Communication GSM quad-band Communication types SMS (bidirectional), telecommunication dial-up connection (CSD) GPRS connection to Internet Signaling 3 LEDs for operating status indication Operating voltage... 3 DC Closed current approx. 20 ma at 24V operating voltage Current during transmission < 500 ma at 24V operating voltage

45 76-3 TO-PASS Compact, 2 AI, WEB Telecontrol module for fault detection/indication, monitoring and remote control 3 43 TO-PASS SIM Com Busy Run Status PC < 05 mm/4.2 in > I/O-SYSTEM < 09 mm/4.29 in > Compact telecontrol module for fault detection/indication and Internet connectivity for machines and installations over a GSM network. The module can be used in many countries via an integrated quad-band GSM modem. Messages are sent via SMS, , fax or phone call. In addition, the process image can be transmitted in an adjustable cycle to a user-selected Internet address. Switching of outputs is performed via SMS. 4 digital inputs, 4 digital outputs and 2 analog inputs with integrated GSM modem. Ideal for applications in distributed stations for temperatures ranging from -20 C to 70 C. Ability to mount on DIN-rail and intuitive user software make unit easy to handle. Operating voltage ranges from 0V to 30VDC. Special functions: Acknowledgment: Acknowledging any fault message Stand-by: Automatic remote switching of the stand-by service Remote parametrization: Programming and process visualization conveniently performed from the office GPRS-dedicated line: Permanent online connection to the process on a WEB server or PC with fixed IP address (e.g., DSL connection) Description TO-PASS Compact, 2 AI, WEB 76-3 Accessories Antennas, USB adapter, GSM modem and power supply units Approvals Approvals r UL 508 see page 47 and Full Line Catalog 200/20 Volume 3, Section 3 for all EU countries Approvals for other countries on request Operating temperature -20 C C Type of mounting DIN 35 rail Antenna connection SMA Wire connection Terminal strips (WAGO 250 Series) with push-wire connection Cross sections 0.5 mm²....5 mm² / AWG Stripped lengths 9 mm /0.35 in Dimensions (mm) W x H x L 09 x 05 x 78 Weight 42 g Storage temperature -40 C C Degree of protection IP20 EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) Digital inputs: Number of inputs 4 (Type 3) Input current max. 2.9 ma at 3 DC Signal voltage (0)... 5 V DC Signal voltage () 7 V... 3 DC Analog inputs: Number of inputs 2 (0/4 ma ma) Internal resistance approx. 200 Ω / 20 ma Measuring error (25 C) < ± % of the full scale value Temperature coefficient < ± 0. % / K of the full scale value Digital outputs: No. of outputs 4 contacts Output current (max.) 0.5 A/ 3 DC, short-circuit protected Communication GSM quad-band Communication types SMS (bidirectional), telecommunication dial-up connection (CSD) GPRS connection to Internet Signaling 3 LEDs for operating status indication Operating voltage... 3 DC Closed current approx. 20 ma at 24V operating voltage Current during transmission < 500 ma at 24V operating voltage

46 TO-PASS Compact Telecontrol module for fault detection/indication, monitoring and remote control I/O-SYSTEM TO-PASS SIM Com Busy Run Status PC < 05 mm/4.2 in > < 09 mm/4.29 in > Universal telecontrol module for fault detection/indication and monitoring of machines and installations over a GSM network. The module can be used in many countries via an integrated quad-band GSM modem. Messages are sent via SMS, , fax or phone call. Switching of outputs is performed via SMS. 8 digital inputs, 4 digital outputs with integrated GSM modem. Ideal for applications in distributed stations for temperatures ranging from -20 C to 70 C. Ability to mount on DIN-rail and intuitive user software make unit easy to handle. Operating voltage ranges from 0V to 30VDC. Special functions: Acknowledgment: Acknowledging any fault message Stand-by: Automatic remote switching of the stand-by service Remote parametrization: Programming and remote control conveniently performed from the office Description TO-PASS Compact Accessories Antennas, USB adapter, GSM modem and power supply units Approvals Approvals r UL 508 see page 47 and Full Line Catalog 200/20 Volume 3, Section 3 for all EU countries Approvals for other countries on request Operating temperature -20 C C Type of mounting DIN 35 rail Antenna connection SMA Wire connection Terminal strips (WAGO 250 Series) with push-wire connection Cross sections 0.5 mm²....5 mm² / AWG Stripped lengths 9 mm /0.35 in Dimensions (mm) W x H x L 09 x 05 x 78 Weight 42 g Storage temperature -40 C C Degree of protection IP20 EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) Digital inputs: Number of inputs 8 (Type 3) Input current max. 2.9 ma at 3 DC Signal voltage (0)... 5 V DC Signal voltage () 7 V... 3 DC Digital outputs: No. of outputs 4 contacts Output current (max.) 0.5 A/ 3 DC, short-circuit protected Communication GSM quad-band Communication types SMS (bidirectional), telecommunication dial-up connection (CSD) Signaling 3 LEDs for operating status indication Operating voltage... 3 DC Closed current approx. 20 ma at 24V operating voltage Current during transmission < 500 ma at 24V operating voltage

47 76-24 TO-PASS Compact, 8 AI, ELog, DLog Telecontrol module for fault detection/indication, monitoring and remote control 3 45 TO-PASS SIM Com Busy Run Status PC < 05 mm/4.2 in > I/O-SYSTEM < 09 mm/4.29 in > Universal telecontrol module for fault detection/indication and monitoring of machines and installations over a GSM network. The module can be used in many countries via an integrated quad-band GSM modem. Messages are sent via SMS, , fax or phone call. An integrated event logger creates the process image of all occurring events and stores all digital and analog values available at the telecontrol module. The data memory stores up to 4096process images in an adjustable cycle time. Switching of outputs is performed via SMS. 8 digital inputs, 8 analog inputs, 4 digital outputs and 2 analog outputs with integrated GSM modem. Ideal for applications in distributed stations for temperatures ranging from -20 C to 70 C. Ability to mount on DIN-rail and intuitive user software make unit easy to handle. Operating voltage ranges from 0V to 30VDC. Special functions: Acknowledgment: Acknowledging any fault message Stand-by: Automatic remote switching of the stand-by service Remote parametrization: Programming and remote control conveniently performed from the office Event logger: Saves all occurring status changes Data logger: Saves all process values with adjustable cycle Description TO-PASS Compact, 8 AI, ELog, DLog Accessories Antennas, USB adapter, GSM modem and power supply units Approvals Approvals r UL 508 see page 47 and Full Line Catalog 200/20 Volume 3, Section 3 for all EU countries Approvals for other countries on request Operating temperature -20 C C Type of mounting DIN 35 rail Antenna connection SMA Wire connection Terminal strips (WAGO 250 Series) with push-wire connection Cross sections 0.5 mm²....5 mm² / AWG Stripped lengths 9 mm /0.35 in Dimensions (mm) W x H x L 09 x 05 x 78 Weight 42 g Storage temperature -40 C C Degree of protection IP20 EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) Digital inputs: Number of inputs 8 (Type 3) Input current max. 2.9 ma at 3 DC Signal voltage (0)... 5 V DC Signal voltage () 7 V... 3 DC Analog inputs: Number of inputs 8 (0/4 ma ma) Internal resistance approx. 200 Ω / 20 ma Measuring error (25 C) < ± % of the full scale value Temperature coefficient < ± 0. % / K of the full scale value Digital outputs: No. of outputs 4 contacts Output current (max.) 0.5 A/ 3 DC, short-circuit protected Analog outputs: No. of outputs 2 (0/4 ma ma) Load impedance 600 Ω Measuring error (25 C) < ± % of the full scale value Temperature coefficient < ± 0. % / K of the full scale value Communication GSM quad-band Communication types SMS (bidirectional), telecommunication dial-up connection (CSD) Signaling 3 LEDs for operating status indication Operating voltage... 3 DC Closed current approx. 20 ma at 24V operating voltage Current during transmission < 500 ma at 24V operating voltage

48 TO-PASS Compact, 8 AI, WEB, MODBUS Telecontrol module for fault detection/indication, monitoring and remote control I/O-SYSTEM TO-PASS SIM Com Busy Run Status PC < 05 mm/4.2 in > < 09 mm/4.29 in > Universal telecontrol module for fault detection/indication and Internet connectivity for machines and installations over a GSM network. The module can be used in many countries via an integrated quad-band GSM modem. Messages are sent via SMS, , fax or phone call. The data memory stores up to 4096 process images in an adjustable cycle time. In addition, the process image can be transmitted in an adjustable cycle to a user-selected Internet address. A Modbus slave (e.g., ) can be connected via RS-232 interface to link additional process values. Switching of outputs is performed via SMS. 8 digital inputs, 8 analog inputs, 4 digital outputs and 2 analog outputs with integrated GSM modem. Ideal for applications in distributed stations for temperatures ranging from -20 C to 70 C. Ability to mount on DIN-rail and intuitive user software make unit easy to handle. Operating voltage ranges from 0V to 30VDC. Description TO-PASS Compact, 8 AI, WEB, MODBUS Accessories Antennas, USB adapter, GSM modem and power supply units Approvals Approvals r UL 508 see page 47 and Full Line Catalog 200/20 Volume 3, Section 3 for all EU countries Approvals for other countries on request Operating temperature -20 C C Type of mounting DIN 35 rail Antenna connection SMA Wire connection Terminal strips (WAGO 250 Series) with push-wire connection Cross sections 0.5 mm²....5 mm² / AWG Stripped lengths 9 mm /0.35 in Dimensions (mm) W x H x L 09 x 05 x 78 Weight 42 g Storage temperature -40 C C Degree of protection IP20 EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007) Special functions: Acknowledgment: Acknowledging any fault message Stand-by: Automatic remote switching of the stand-by service Remote parametrization: Programming and process visualization conveniently performed from the office GPRS-dedicated line: Permanent online connection to the process on a WEB server or PC with fixed IP address (e.g., DSL connection) Event logger: Saves all occurring status changes Data logger: Saves all process values with adjustable cycle Digital inputs: Number of inputs 8 (Type 3) Input current max. 2.9 ma at 3 DC Signal voltage (0)... 5 V DC Signal voltage () 7 V... 3 DC Analog inputs: Number of inputs 8 (0/4 ma ma) Internal resistance approx. 200 Ω / 20 ma Measuring error (25 C) < ± % of the full scale value Temperature coefficient < ± 0. % / K of the full scale value Digital outputs: No. of outputs 4 contacts Output current (max.) 0.5 A/ 3 DC, short-circuit protected Analog outputs: No. of outputs 2 (0/4 ma ma) Load impedance 600 Ω Measuring error (25 C) < ± % of the full scale value Temperature coefficient < ± 0. % / K of the full scale value Communication GSM quad-band Communication types SMS (bidirectional), telecommunication dial-up connection (CSD) GPRS connection to Internet Signaling 3 LEDs for operating status indication Operating voltage... 3 DC Closed current approx. 20 ma at 24V operating voltage Current during transmission < 500 ma at 24V operating voltage

49 76-34 TO-PASS Mobile, 4 AI Telecontrol module for fault detection/indication, position monitoring and remote control 3 47 TO-PASS SIM Com Busy Run Status PC < 05 mm/4.2 in > I/O-SYSTEM < 09 mm/4.29 in > Universal telecontrol module for fault detection/indication and position monitoring of machines and products over a GSM network. The module can be used in many countries via an integrated quad-band GSM modem. Messages are sent via SMS, , fax or phone call. The data memory stores up to 4096 process images in an adjustable cycle time. Switching of outputs is performed via SMS. The module is equipped with 4 digital inputs, 4 analog inputs, 2 digital outputs and GPS position data, including an integrated GSM modem. Ideal for applications in distributed stations for temperatures ranging from -20 C to 70 C. Ability to mount on DIN-rail and intuitive user software make unit easy to handle. Operating voltage 0V... 30V DC. Special functions: Acknowledgment: Acknowledging any fault message Stand-by: Automatic remote switching of the stand-by service Remote parameterization: Programming and remote control conveniently performed from the office Event logger: Saves all occurring status changes Data logger: Saves all process values with adjustable cycle Description TO-PASS Mobile, 4 AI Accessories Antennas, USB adapter, GSM modem and power supply units Approvals Approvals see page 37 and Full Line Catalog 200/20 Volume 3, Section 3 for all EU countries Approvals for other countries on request Operating temperature -20 C C Type of mounting DIN 35 rail Antenna connection SMA socket (for both GSM and GPS) Wire connection Terminal strips (WAGO 250 Series) with push-wire connection Cross sections 0.5 mm²....5 mm² / AWG Stripped lengths 9 mm /0.35 in Dimensions (mm) W x H x L 09 x 05 x 78 Weight 42 g Storage temperature -40 C C Degree of protection IP20 Digital inputs: Number of inputs 4 (Type 3) Input current max. 2.9 ma at 3 DC Signal voltage (0)... 5 V DC Signal voltage () 7 V... 3 DC Analog inputs: Number of inputs 4 (0/4 ma ma) Internal resistance approx. 200 Ω / 20 ma Measuring error (25 C) < ± % of the full scale value Temperature coefficient < ± 0. % / K of the full scale value Digital outputs: No. of outputs 2 contacts Output current (max.) 0.5 A/ 3 DC, short-circuit protected Communication GSM quad-band Communication types SMS (bidirectional), telecommunication dial-up connection (CSD) Signaling 3 LEDs for operating status indication Operating voltage... 3 DC Closed current approx. 35 ma at 24V operating voltage Current during transmission < 500 ma at 24V operating voltage EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007)

50 TO-PASS Mobile, 4 AI, Web, MODBUS Telecontrol module for fault detection/indication, position monitoring and remote control I/O-SYSTEM TO-PASS SIM Com Busy Run Status PC < 05 mm/4.2 in > < 09 mm/4.29 in > Universal telecontrol module for fault detection/indication, position monitoring and Internet connectivity of machines/products over a GSM network. The module can be used in many countries via an integrated quad-band GSM modem. Messages are sent via SMS, , fax or phone call. The data memory stores up to 4096 process images in an adjustable cycle time. In addition, the process image and GPS position data can be transmitted in an adjustable cycle to a userselected Internet address. A MODBUS slave (e.g., ) can be connected via RS-232 interface to link additional process values. Switching of outputs is performed via SMS. The module is equipped with 4 digital inputs, 4 analog inputs, 2 digital outputs and GPS position data, including an integrated GSM modem. Ideal for applications in distributed stations for temperatures ranging from -20 C to 70 C. Ability to mount on DIN-rail and intuitive user software make unit easy to handle. Operating voltage 0V... 30V DC. Description TO-PASS Mobile, 4 AI, Web, MODBUS Accessories Antennas, USB adapter, GSM modem and power supply units Approvals Approvals see page 37 and Full Line Catalog 200/20 Volume 3, Section 3 for all EU countries Approvals for other countries on request Operating temperature -20 C C Type of mounting DIN 35 rail Antenna connection SMA socket (for both GSM and GPS) Wire connection Terminal strips (WAGO 250 Series) with push-wire connection Cross sections 0.5 mm²....5 mm² / AWG Stripped lengths 9 mm /0.35 in Dimensions (mm) W x H x L 09 x 05 x 78 Weight 42 g Storage temperature -40 C C Degree of protection IP20 Special functions: Acknowledgment: Acknowledging any fault message Stand-by: Automatic remote switching of the stand-by service Remote parameterization: Programming and process visualization conveniently performed from the office GPRS-dedicated line: Permanent online connection to the process on a WEB server or PC with fixed IP address (e.g., DSL connection) Event logger: Saves all occurring status changes Data logger: Saves all process values with adjustable cycle Digital inputs: Number of inputs 4 (Type 3) Input current max. 2.9 ma at 3 DC Signal voltage (0)... 5 V DC Signal voltage () 7 V... 3 DC Analog inputs: Number of inputs 4 (0/4 ma ma) Internal resistance approx. 200 Ω / 20 ma Measuring error (25 C) < ± % of the full scale value Temperature coefficient < ± 0. % / K of the full scale value Digital outputs: No. of outputs 2 contacts Output current (max.) 0.5 A/ 3 DC, short-circuit protected Communication GSM quad-band Communication types SMS (bidirectional), telecommunication dial-up connection (CSD) GPRS connection to Internet Signaling 3 LEDs for operating status indication Operating voltage... 3 DC Closed current approx. 35 ma at 24V operating voltage Current during transmission < 500 ma at 24V operating voltage EMC: - immunity to interference acc. to EN (2005) EMC: - emission of interference acc. to EN (2007)

51 Antenna Accessories 3 49 Self-adhesive antenna Rod antenna Magnetic foot antenna Theft-proof antenna Description I/O-SYSTEM Self-adhesive antenna with 2.5m cable and SMA straight plug GSM/ UMTS/ Bluetooth / WLAN 850/900/800/900/200/2400 MHz Dimension: 7 mm x 2 mm Cable length: 2.5 m Cable type: RG74 Gain: 2.5 dbi VSWR: <.5 Connector: SMA straight plug Rod antenna with m cable and SMA straight plug GSM/ 850/900/800/900 MHz Height: 298 mm Cable length: m Cable type: RG58 Gain: 2.2 dbi VSWR: <.6 Connector: SMA straight plug Magnetic foot antenna with 2.5m cable and SMA straight plug GSM/ UMTS 850/ 900/ 800/ 900/ 200 MHz Height: 88 mm Cable length: 2.5 m Cable type: RG74 Gain: 2.2 dbi VSWR: <2.0 Connector: SMA straight plug Theft-proof antenna with m cable and SMA straight plug GSM/ UMTS/ Bluetooth / WLAN 850/900/800/900/200/2400 MHz Dimension: 70 mm x 5 mm Cable length: m Cable type: RG74 Max. gain: 2.2 dbi VSWR: <2.0 Connector: SMA straight plug Adaptor Adaptor Adaptor Cable, SMA socket/ SMA plug Antenna splitter RF lighting protector Description Adaptor, FME plug to SMA plug GSM/ UMTS/ Bluetooth / WLAN Adaptor, FME socket to SMA socket GSM/ UMTS/ Bluetooth / WLAN Adaptor, SMA plug to SMA plug GSM/ UMTS/ Bluetooth / WLAN Cable with SMA socket and SMA plug, m long, H55 type GSM/ UMTS/ Bluetooth / WLAN / Cable with SMA socket and SMA plug, 3 m long, H55 type GSM/ UMTS/ Bluetooth / WLAN / Cable with SMA socket and SMA plug, 5 m long, H55 type GSM/ UMTS/ Bluetooth / WLAN / Cable with SMA socket and SMA plug, 0 m long, H55 type GSM/ UMTS/ Bluetooth / WLAN / Antenna splitter with 3 SMA sockets GSM/ UMTS/ Bluetooth / WLAN RF lighting protector, SMA socket to SMA socket GSM/ UMTS/ Bluetooth / WLAN

52 Digital Input/Output Module DC / 0.5 A 8 inputs/outputs (8 x M8) I/O-SYSTEM Module marking System bus input (3) LED indicators X 7 X 5 X X 8 X 6 X 4 X 2 System bus output (3) Digital inputs / outputs (2) Channel marking Supply input () X 0 U LS U A Supply output () Short description: This digital input/output module records binary signals from switches, sensors and proximity switches (BEROs), and it controls actuators (e.g., magnetic valves, DC contactors, indicators). Characteristics: - 8 digital inputs/outputs DC / 0.5 A - Input/output, parametrizable channel for channel - Diagnostic capable (per channel/per module) - Parametrizable (operating mode, filter, inversion, substitute value strategy, substitute value, manual mode, online simulation and diagnostics) Included: x WMB module marker card, orange x marker strip 2 x M8 protective cap Note: The module is supported by all (programmable) fieldbus couplers (Exception: PROFINET IO Fieldbus Coupler). Please also observe the notes in the manual. Description 8DIO 24V DC 0.5A (8xM8) Accessories Marker strips, marking pen, spacer see Full Line Catalog 200/20 module and protective caps Volume 3 IP67 cables and connectors see Full Line Catalog 200/20 Volume 3 Module supply: Connection type () M2 connectors, A coded, 4 poles; Derating must be observed Current carrying capacity of supply connections max. 8 A (U LS : 4 A, U A : 4 A) Supply voltage Logic and sensor voltage UL S DC (-25 % %) Actuator voltage U A DC (-25 %...30 %) Supply current Logic and sensor current I LS typ. 45 ma (only logic part) Actuator current I A typ. 75 ma sensors/actuators (max. 800 ma) load Protection Reverse voltage protection for U LS U A Short-circuit protection for sensor/actuator supply Digital inputs: Number of inputs 8 Connection type (2) M8 connectors, 3 poles Wire connection 2- to 3-wire Input filter Hardware: 0 μs Software: parametrizable Input characteristic Type 2, acc. to IEC 63-2 Signal voltage (0) -3 V... 5 V DC Signal voltage () V... 3 DC Input wiring High-side switching Input voltage DC (-3 VDC < U IN < 3DC); Power from U A is strongly recommended, recovery for voltages > U A Input current (typ.) 7.0 ma Connection of 2-wire BEROs max..5 ma admissible closed current Cable length, unshielded 30 m Input characteristic: Input voltage Typical input current DC 0 5 V 2.7 ma V 6.8 ma 7 ma 3 7. ma

53 6 5 System bus Input Output M2, B coded Digital Inputs/Outputs X... X8 : RD/TD 2: RD--/TD-- 3: TD--/RD-- 4: TD/RD 5: GND Housing: Shield : 3: U A Digital Input/Output X... X8 M8 3 Block diagram of an input/output Diagnostics sensor/actuator supply Input Supply M2 2 4 I/O-SYSTEM Logic 0 nf 0 nf M8 4: In-/Output 4 Output Input/Output Error F Supply Input Output M2, A coded : U LS 2: U A 3: U LS 4: U A 270 pf 270 pf Module mount Digital outputs: No. of outputs 8 Connection type (2) M2 connectors, A coded, 5 poles Wire connection 2- to 3-wire Output voltage U A Output current (per channel) 0.5 A (max. 0.6 A), short-circuit/overload proof (thermal disconnection) Voltage drop against U A at 500 ma max. 0.2 V DC Output current (module) max. 4 A Leakage current in OFF state typ. 5 μa Output circuit High-side switching Information on actuator selection: Delay time HW from "0" to "" (0-90%) typ. 90 μs (resistive load) Delay time HW from "" to "0" (0-90%) typ. 30 μs (resistive load) Rise time from "0" to "" typ. 60 μs (resistive load) Rise time from "" to "0" typ. 45 μs (resistive load) Cable length 30 m Reverse current (in case of recovery for voltages > U A ) 0,5 A (error: channel) Type of load Inductive, resistive loads and lamps Switching frequency Inductive load approx. 20 Hz Resistive load approx. 500 Hz Lamp load approx. 500 Hz Parallel connection of 2 outputs for power boost for redundant actuation of a load Type of protective circuit External protection (e.g., recovery diodes) Output resistance < 0.4 Ω Operating state influence on output: PLC CPU stop Acc. to substitute value strategy Supply voltage under rated voltage tolerance status Interruption of supply voltage status Output operation Non-latching Overload behavior Automatic restart Counters*: No. of counters 2 Counter type Event, gate time, pulse duration counter Counting/switching frequency 0 Hz... khz System bus: Connection type (3) M2 connectors, B coded, 5 poles, shielded Standards and approvals: r UL 508 Conformity marking Isolation: Channel - Channel no U LS, U A, system bus 50 DC each Configurable functions: Operating mode (per module) DO-Module/DI-Module/DIO-Module/ DIO counter*/dio 2 counters* Input filter (per channel) 0./ 0.5/ 3 /5 /20 ms/ filter off Inversion (per channel) On/off Substitute value strategy (per channel) Switch substitute value/hold last value Substitute value (per channel) 0/ Manual mode (per channel) On/off Manual mode value (per channel) 0/ Online simulation (per channel) Lock/unlock; simulation value: 0/ Online simulation (per channel/module) Diagnostics I/O diagnostics: I/O diagnostics (per channel) Overtemperature I/O diagnostics (per module) Short-circuit of sensor/actuator supply Undervoltage (U LS U A ) Process image: Process data width Depends on operating mode LED indicators: SB: System bus status LED (green/red) F: Error status LED (red) : Input and output signal status LED (yellow) : Output diagnostics LED (red) U LS U A : Supply status LED (green) Indicators Non-latching * pending General Specifications Dimensions (mm) W x H x L 50 x 35.7 x 7 Weight approx. 230 g

54 Digital Input/Output Module DC / 0.5 A 8 inputs/outputs (4 x M2, two inputs/outputs per connector) Module marking System bus input (3) System bus output (3) I/O-SYSTEM LED indicators X X 4 Digital inputs / outputs (2) 0 X 2 X 3 Channel marking Supply input () U LS U A Supply output () Short description: This digital input/output module records binary signals from switches, sensors and proximity switches (BEROs), and it controls actuators (e.g., magnetic valves, DC contactors, indicators). Characteristics: - 8 digital inputs/outputs DC / 0.5 A - Input/output, parametrizable channel for channel - Diagnostic capable (per channel/per module) - Parametrizable (operating mode, filter, inversion, substitute value strategy, substitute value, manual mode, online simulation and diagnostics) Included: x WMB module marker card, orange x marker strip 2 x M8 protective cap Note: The module is supported by all (programmable) fieldbus couplers (Exception: PROFINET IO Fieldbus Coupler). Please also observe the notes in the manual. Description 8DIO 24V DC 0.5A (4xM2) Accessories Marker strips, marking pen, spacer see Full Line Catalog 200/20 module and protective caps Volume 3 IP67 cables and connectors see Full Line Catalog 200/20 Volume 3 Module supply: Connection type () M2 connectors, A coded, 4 poles; Derating must be observed Current carrying capacity of supply connections max. 8 A (U LS : 4 A, U A : 4 A) Supply voltage Logic and sensor voltage UL S DC (-25 %...30 %) Actuator voltage U A DC (-25 %...30 %) Supply current Logic and sensor current I LS typ. 45 ma (only logic part) Actuator current I A typ. 75 ma sensors/actuators (max. 800 ma) load Protection Reverse voltage protection for U LS U A Short-circuit protection for sensor/actuator supply Digital inputs: Number of inputs 8 Connection type (2) M2 connectors, A coded, 5 poles Wire connection 2- to 3-wire Input filter Hardware: 0 μs Software: parametrizable Input characteristic Type 2, acc. to IEC 63-2 Signal voltage (0) -3 V... 5 V DC Signal voltage () V... 3 DC Input wiring High-side switching Input voltage DC (-3 VDC < U IN < 3DC); Power from U A is strongly recommended, recovery for voltages > U A Input current (typ.) 7.0 ma Connection of 2-wire BEROs max..5 ma admissible closed current Cable length, unshielded 30 m Input characteristic: Input voltage Typical input current DC 0 5 V 2.7 ma V 6.8 ma 7 ma 3 7. ma

55 6 53 System bus Input Output M2, B coded Digital Inputs/Outputs X... X4 (doppelt belegt) : RD/TD 2: RD--/TD-- 3: TD--/RD-- 4: TD/RD 5: GND Housing: Shield : 3: U A Digital Input/Output X... X4 M2 3 Block diagram of an input/output Diagnostics sensor/actuator supply Input Supply M2 2 4 I/O-SYSTEM M2, A coded 5: n.c. 4: In-/Output A 2: In-/Output B 4/2 Output Logic 0 nf 0 nf Input/Output Error F Supply Input Output M2, A coded : U LS 2: U A 3: U LS 4: U A 270 pf 270 pf Module mount Digital outputs: No. of outputs 8 Connection type (2) M2 connectors, A coded, 5 poles Wire connection 2- to 3-wire Output voltage U A Output current (per channel) 0.5 A (max. 0.6 A), short-circuit/overload proof (thermal disconnection) Voltage drop against U A at 500 ma max. 0.2 V DC Output current (module) max. 4 A Leakage current in OFF state typ. 5 μa Output circuit High-side switching Information on actuator selection: Delay time HW from "0" to "" (0-90%) typ. 90 μs (resistive load) Delay time HW from "" to "0" (0-90%) typ. 30 μs (resistive load) Rise time from "0" to "" typ. 60 μs (resistive load) Rise time from "" to "0" typ. 45 μs (resistive load) Cable length 30 m Reverse current (in case of recovery for voltages > U A ) 0,5 A (error: channel) Type of load Inductive, resistive loads and lamps Switching frequency Inductive load approx. 20 Hz Resistive load approx. 500 Hz Lamp load approx. 500 Hz Parallel connection of 2 outputs for power boost for redundant actuation of a load Type of protective circuit External protection (e.g., recovery diodes) Output resistance < 0.4 Ω Operating state influence on output: PLC CPU stop Acc. to substitute value strategy Supply voltage under rated voltage tolerance status Interruption of supply voltage status Output operation Non-latching Overload behavior Automatic restart Counter*: No. of counters 2 Counter type Event, gate time, pulse duration counter Counting/switching frequency 0 Hz... khz System bus: Connection type (3) M2 connectors, B coded, 5 poles, shielded Standards and approvals: r UL 508 Conformity marking Isolation: Channel - Channel no U LS, U A, system bus 50 DC each Configurable functions: Operating mode (per module) DO-Module/DI-Module/DIO-Module/ DIO counter*/dio 2 counters* Input filter (per channel) 0./ 0.5/ 3 /5 /20 ms/ filter off Inversion (per channel) On/off Substitute value strategy (per channel) Switch substitute value/hold last value Substitute value (per channel) 0/ Manual mode (per channel) On/off Manual mode value (per channel) 0/ Online simulation (per channel) Lock/unlock; simulation value: 0/ Online simulation (per channel/module) Diagnostics I/O diagnostics: I/O diagnostics (per channel) Overtemperature I/O diagnostics (per module) Short-circuit of sensor/actuator supply Undervoltage (U LS U A ) Process image: Process data width Depends on operating mode LED indicators: SB: System bus status LED (green/red) F: Error status LED (red) : Input and output signal status LED (yellow) : Output diagnostics LED (red) U LS U A : Supply status LED (green) Indicators Non-latching * pending General Specifications Dimensions (mm) W x H x L 50 x 35.7 x 7 Weight approx. 230 g

56 6 54 WAGO-SPEEDWAY 767 S-BUS cable suitable for drag chains (system bus cable), assembled on one end I/O-SYSTEM ø5 42 L*) 35±2 (mm) M2 socket, straight, B coded, suitable for drag chains M2 socket, straight, one free cable end, 2.0 m / M2 socket, straight, one free cable end, 5.0 m / M2 socket, straight, one free cable end, 0.0 m / M2 socket, straight, one free cable end, 20.0 m / Pin - 5: 0.4 mm² red 2 black 3 blue 4 brown 5 yellow, green, orange, gray 32 33,5 L*) 35±2 (mm) Pin - 5: 0.4 mm² red 2 black 3 blue 4 brown 5 yellow, green, orange, gray ø5 M2 socket, right angle, B coded, suitable for drag chains M2 socket, right angle, one free cable end, 2.0 m / M2 socket, right angle, one free cable end, 5.0 m / M2 socket, right angle, one free cable end, 0.0 m / M2 socket, right angle, one free cable end, 20.0 m / ø5 M2x L*) 48,5 35± Pin - 5: 0.4 mm² red 2 black 3 blue 4 brown 5 yellow, green, orange, gray (mm) M2 plug, straight, B coded, suitable for drag chains M2 plug, straight, one free cable end, 2.0 m / M2 plug, straight, one free cable end, 5.0 m / M2 plug, straight, one free cable end, 0.0 m / M2 plug, straight, one free cable end, 20.0 m / ,5 L*) 33,5 35±2 (mm) Pin - 5: 0.4 mm² red 2 black 3 blue 4 brown 5 yellow, green, orange, gray M2x ø5 M2 plug, right angle, B coded, suitable for drag chains M2 plug, right angle, one free cable end, 2.0 m / M2 plug, right angle, one free cable end, 5.0 m / M2 plug, right angle, one free cable end, 0.0 m / M2 plug, right angle, one free cable end, 20.0 m / *) Cable length

57 WAGO-SPEEDWAY 767 S-BUS cable suitable for drag chains (system bus cable), assembled on both ends and unassembled 6 55 ø5 42 L*) 48,5 (mm) M2 socket, straight / M2 plug, straight, B coded, suitable for drag chains M2 socket, straight, M2 plug, straight, 0.2 m / M2 socket, straight, M2 plug, straight, 0.3 m / M2 socket, straight, M2 plug, straight, 0.5 m / M2 socket, straight, M2 plug, straight,.0 m / M2 socket, straight, M2 plug, straight, 2.0 m / M2 socket, straight, M2 plug, straight, 5.0 m / M2 socket, straight, M2 plug, straight, 0.0 m / M2 socket, straight, M2 plug, straight, 20.0 m / M2 socket, straight, M2 plug, straight, 50.0 m / M2x ø Pin - 5: 0.4 mm² red 2 black 3 blue 4 brown 5 yellow, green, orange, gray I/O-SYSTEM 32 33,5 L*) 33,5 (mm) 38, Pin - 5: 0.4 mm² red 2 black 3 blue 4 brown 5 yellow, green, orange, gray ø5 M2x ø5 M2 socket, right angle / M2 plug, right angle, B coded, suitable for drag chains M2 socket, right angle, M2 plug, right angle, 0.2 m / M2 socket, right angle, M2 plug, right angle, 0.3 m / M2 socket, right angle, M2 plug, right angle, 0.5 m / M2 socket, right angle, M2 plug, right angle,.0 m / M2 socket, right angle, M2 plug, right angle, 2.0 m / M2 socket, right angle, M2 plug, right angle, 5.0 m / M2 socket, right angle, M2 plug, right angle, 0.0 m / M2 socket, right angle, M2 plug, right angle, 20.0 m / M2 socket, right angle, M2 plug, right angle, 50.0 m / *) Cable length S-Bus cable, not fitted with connectors, suitable for drag chains S-BUS cable, not fitted with connectors, 25.0 m / S-BUS cable, not fitted with connectors, 50.0 m / S-BUS cable, not fitted with connectors, 00.0 m /

58 56 JUMPFLEX Relay Interface Modules < 96 mm/3.76 in > < 94 mm/3.68 in > _> _> 6 mm/0.23 in With 2 relays, with make contact ( a) for normal switching power Nominal input voltage V N AC/DC A 3 Note: Inductive loads have to be attenuated by an appropriate protective circuit in order to protect relay coils A4 and contacts. Description V N I N JUMPFLEX Relais, for DIN 35 rail A2 A3 4 AC/DC 0 ma Accessories see Full Line Catalog 200/20 Interface Modules Contact material AgSnO 2 Input voltage range V N -5 % % Max. switching voltage 25 AC Max. continuous current (terminal blocks in a row) 4 A Max. Switching power (resistive) AC 00A; DC see load limit curve Recommended minimum load 00 ma / 2 V AC/DC Max. switching rate with / without load 6 min - / 20 s - Operating power < 300 mw / < 700 mw Pull-in/drop-out/bounce time typ. 5 ms / 6 ms / 5 ms Nominal operating mode continuous duty Dielectric strength contact-coil 2.5 kv Surge capacity open contact kv eff Nominal voltage acc. to VDE 00 Part /4.97, 25 / 4 kv / 3 IEC Mechanical life 5 x 0 6 switching operations Mechanical life at max. load (resistance) 5 x 0 4 switching operations Ambient operating temperature (V N ) -25 C C Storage temperature -40 C C Dimensions (mm) W x H x L 6 x 96 x 94 Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm² mm² / AWG fine-stranded: 0.34 mm² mm² / AWG Stripped lengths mm / 0.37 in Approvals VDE 00 / EN 60664; VDE 0435 / EN 680-

59 JUMPFLEX Optocouplers S 57 Optocoupler Input: 2 x DC Output: 2 x 9 6DC / 0. A Optocoupler Input: 2 x DC Output: 2 x 3 3DC / 3 A < 96 mm/3.76 in > < 94 mm/3.68 in > _> _> 6 mm/0.23 in Interface Modules A 3 A 3 A2 4 RL A2 4 RL A3 23 A3 23 A4 24 RL A4 24 RL Description JUMPFLEX Optocoupler, for DIN 35 rail Accessories see Full Line Catalog 200/20 Interface Modules Control circuit: Nominal input voltage (V N ) 2 x DC 2 x DC Input voltage range V N -30 % 25 % V N -30 % 25 % Input voltage range (low level)... 5 V... 5 V Input voltage range (high level) 6.8 V V... 3 Input current range 3 ma ma 4.25 ma... ma Nominal input current (I N ) 5.6 ma 7.75 ma Load circuit: Switching voltage 2 x DC 9 V x DC 3 V... 3 Max. switching current 2 x 0. A DC 2 x 3 A DC Peak reverse voltage 0 55 V Forward voltage at max. switching current < 2 V < 0.2 V Leakage current at nominal voltage 25 μa 250 μa Switch on/switch off time 20 μs / 20 μs 25 μs / 250 μs Max. switching frequency.5 khz 300 Hz Dielectric strength control/switching circuit 2.5 kv 2.5 kv Dielectric strength channel/channel 4 kv 4 kv Ambient operating temperature -25 C C -25 C C Storage temperature -40 C C -40 C C Dimensions (mm) W x H x L 6 x 96 x 94 6 x 96 x 94 Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP S CAGE CLAMP S Cross sections solid: 0.08 mm² mm² / AWG fine-stranded: 0.34 mm² mm² / AWG solid: 0.08 mm² mm² / AWG fine-stranded: 0.34 mm² mm² / AWG Stripped lengths mm / 0.37 in mm / 0.37 in 8

60 58 JUMPFLEX Optocouplers Interface Modules Optocoupler Input: 2 x DC Output: 2 changeover contacts, 2 x DC / 0.5 A A 2 Description JUMPFLEX Optocoupler, for DIN 35 rail A RL RL Accessories see Full Line Catalog 200/20 Interface Modules Control circuit: Nominal input voltage (V N ) DC Input voltage range V N -30 % 25 % Input voltage range (low level)... 5 V Input voltage range (high level) 6.8 V... 3 Input current range 5.3 ma ma Nominal input current (I N ) 5.9 ma Load circuit: Switching voltage 2 x DC 3 V... 3 Max. switching current 2 x 500 ma Min. switching current 2 x 0.5 ma Forward voltage at max. switching current <.5 V Leakage current at nominal voltage 20 μa Switch on/switch off time 25 μs / 250 μs Max. switching frequency.5 khz Dielectric strength control/switching circuit 3.75 kv Ambient operating temperature -25 C C Storage temperature -40 C C Dimensions (mm) W x H x L 6 x 96 x 94 Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm² mm² / AWG fine-stranded: 0.34 mm² mm² / AWG Stripped lengths mm / 0.37 in

61 S 59

62 60 WAGO Ribbon Cables Interface Modules 4-pole female connector 4-pole female connector 6-pole female connector 6-pole female connector The 4-pin cables transmit signals one-to-one from the 4-pole female connector and are available in -, 2- and 3-meter lengths. The 6-pin cables transmit signals one-to-one from the 6-pole female connector and are available in -, 2- and 3-meter lengths. Signal transmission from the Interface Adapter is also possible. Suitable for system wiring when combined with the JUMPFLEX Interface Adapter ( and ) Suitable for system wiring when combined with the JUMPFLEX Interface Adapter ( ) Description Description WAGO ribbon cable 4/4, m long / WAGO ribbon cable 6/6, m long /30-00 WAGO ribbon cable 4/4, 2m long / WAGO ribbon cable 6/6, 2m long / WAGO ribbon cable 4/4, 3m long / WAGO ribbon cable 6/6, 3m long / Connections 2 x 4-pole female connector acc. to DIN 465 Connections 2 x 6-pole female connector acc. to DIN 465 Wire cross-section 0.4 mm 2 LiYY Wire cross-section 0.4 mm 2 LiYY Color coding acc. to DIN VDE 4700 Color coding acc. to DIN VDE 4700 Current per channel max. A Current per channel max. A Operating temperature -25 C C Operating temperature -25 C C Degree of protection IP20 Degree of protection IP20 Length m ( /300-00) 2 m ( / ) 3 m ( / ) Length m ( /30-00) 2 m ( /30-200) 3 m ( /30-300)

63 WAGO Ribbon Cables 6 Interface Modules 20-pole female connector 20-pole female connector 4-pole female connector 4-pole female connector 5-pole D-sub female connector 5-pole D-sub female connector The cables provide fast and easy connection of WAGO I/O modules featuring ribbon cable connectors. The following WAGO I/O modules and adapters are compatible: (6 DO) -- > (DO) (8 DO / 8 DI) --> (DO) and (DI) The ribbon cables are available in -, 2- and 3-meter lengths -- each has one 20-pole or two 4-pole female connectors on the ends. Suitable for system wiring when combined with the JUMPFLEX Interface Adapter ( and ) The cables provide fast and easy connection of WAGO I/O modules featuring ribbon cable connectors. The following WAGO I/O modules and D-sub adapters are compatible: (6 DO) --> (DO) The ribbon cables are available in -, 2- and 3-meter lengths -- each has one 20-pole or two 5-pole female connectors on the ends. Suitable for system wiring when combined with the JUMPFLEX Interface Adapter ( ) Description Description WAGO ribbon cable 20/2x4, m long / WAGO ribbon cable 20/2x5, m long / WAGO ribbon cable 20/2x4, 2m long / WAGO ribbon cable 20/2x5, 2m long / WAGO ribbon cable 20/2x4, 3m long / WAGO ribbon cable 20/2x5, 3m long / Connections x 20-pole female connector / 2 x 4- pole female connector to DIN 465 Connections x 20-pole female connector to DIN 465 / 2 x 5-pole D-sub female connector to DIN 4652 Wire cross-section 0.4 mm 2 LiYY Wire cross-section 0.4 mm 2 LiYY Color coding acc. to DIN VDE 4700 Color coding acc. to DIN VDE 4700 Current per channel max. A Current per channel max. A Operating temperature -25 C C Operating temperature -25 C C Degree of protection IP20 Degree of protection IP20 Length m ( /304-00) 2 m ( / ) 3 m ( / ) Length m ( /306-00) 2 m ( / ) 3 m ( / )

64 62 Sockets with Miniature Switching Relay Interface Modules Switching current (A) change over contact 2 change over contacts Relay with changeover contact Electrical and mechanical status indication Manual operation (Relay height: 25 mm) Nominal input voltage V N : DC, 48 V DC, DC Relay with 2 changeover contact Electrical and mechanical status indication Manual operation (Relay height: 25 mm) Nominal input voltage V N : DC, 48 V DC, DC Switching voltage (V) Description V N I N Relay sockets with pluggable miniature switching relay, for DIN 35 rail A A2-4 2 V N I N DC 6.7 ma DC 6.7 ma V DC 8.3 ma V DC 8.3 ma DC 3.6 ma DC 3.6 ma A A Accessories see Full Line Catalog 200/20 Volume 4 Contact material AgNi AgNi Input voltage range U N ± 0 % U N ± 0 % Max. switching voltage 25 AC 25 AC Max. continuous current 6 A 2 x 8 A Max. Switching power (resistive) 4 kva AC 2 x 2 kva AC Operating power 400 mw typ. 400 mw typ. Responce time/drop-out time max. 5 ms / 8 ms 5 ms / 8 ms Nominal operating mode continuous duty continuous duty Dielectric strength contact-coil 5 kv 5 kv Dielectric strength open contact kv kv Nominal voltage acc. to VDE 00 Part /4.97, IEC / 4 kv / 3 25 / 4 kv / 3 Mechanical life 5 x 0 6 switching operations 5 x 0 6 switching operations Degree of protection IP20 IP20 Ambient operating temperature -25 C C -25 C C Storage temperature -40 C C -40 C C Dimensions (mm) W x H x L 5 x 73 x 86 5 x 73 x 86 Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP S CAGE CLAMP S Cross sections 0.34 mm² mm² / AWG mm² mm² / AWG Stripped lengths mm / 0.37 in mm / 0.37 in Standards/Specifications DIN VDE 040 part, DIN EN 640; DIN VDE 060, EN 5078; degree of protection II DIN VDE 040 part, DIN EN 640; DIN VDE 060, EN 5078; degree of protection II

65 S 63 Switching current (A) change over contact 2 change over contacts Relay with changeover contact Electrical and mechanical status indication Manual operation (Relay height: 25 mm) Nominal input voltage V N : AC, 5 V AC, 23 AC Relay with 2 changeover contact Electrical and mechanical status indication Manual operation (Relay height: 25 mm) Nominal input voltage V N : AC, 5 V AC, 23 AC Interface Modules Switching voltage (V) Similar to illustration Similar to illustration Description V N I N Relay sockets with pluggable miniature switching relay, for DIN 35 rail A A2 4 2 V N I N DC 3.6 ma DC 3.6 ma V AC 6.6 ma V AC 6.6 ma AC 3.2 ma AC 3.2 ma A A Accessories see Full Line Catalog 200/20 Volume 4 Contact material AgNi AgNi Input voltage range U N ± 0 % U N ± 0 % Max. switching voltage 25 AC 25 AC Max. continuous current 6 A 2 x 8 A Max. Switching power (resistive) 4 kva AC 2 x 2 kva AC Operating power 0.75 VA typ VA typ. Responce time/drop-out time max. 5 ms / 8 ms 5 ms / 8 ms Nominal operating mode continuous duty continuous duty Dielectric strength contact-coil 5 kv 5 kv Dielectric strength open contact kv kv Nominal voltage acc. to VDE 00 Part /4.97, IEC / 4 kv / 3 25 / 4 kv / 3 Mechanical life 5 x 0 6 switching operations 5 x 0 6 switching operations Degree of protection IP20 IP20 Ambient operating temperature -25 C C -25 C C Storage temperature -40 C C -40 C C Dimensions (mm) W x H x L 5 x 73 x 86 5 x 73 x 86 Height from upper-edge of DIN 35 rail Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP S CAGE CLAMP S Cross sections 0.34 mm² mm² / AWG mm² mm² / AWG Stripped lengths mm / 0.37 in mm / 0.37 in Standards/Specifications DIN VDE 040 part, DIN EN 640; DIN VDE 060, EN 5078; degree of protection II DIN VDE 040 part, DIN EN 640; DIN VDE 060, EN 5078; degree of protection II

66 64 Relay Modules in DIN-Rail Mounted Enclosure Relay with make contact ( a), manual-0-automatic switch with monitoring contact Capability of different lamp loads: (switching operations acc. to EN 60669) Interface Modules Switching current (A) 00 0 AC resistive load DC resistive load Switching voltage (V) Type of load Capability Electrical life Incandescent lamp 2200 W Halogen lamp 23 AC 400 W Halogen trafo 2A Fluorescent lamp not comp., CB, cos ϕ 0,4-0,6 20 x 58 W Fluorescent lamp comp., Conv. ballast, C parallel 9 x 58 W Fluorescent lamp comp., Conv. ballast, Duo-circuit 600 W Fluorescent lamp with electronic ballast 2 x 58 W Energy saving lamp 5 W 25 pcs Energy saving lamp 3 W 30 pcs Energy saving lamp 9 W 38 pcs Gas discharge lamp 000 W Dulux-Lamp not compensated 800 W Dulux-Lamp compensated 500 W Max. capacitance at 23 AC 60 µf min Note:Inductive loads have to be attenuated by an appropriate protective circuit in order to protect relay coils and contacts! Description V N Relay modules in DIN-rail mounted enclosure, for DIN 35 rail A 0 A (24V) A3 B n.c. B2 A2 - A2 - A = Automatic (AUTO) 0 = OFF = Manual ON (MAN) DC Accessories see Full Line Catalog 200/20 Volume 4 Contact material Ag alloy Input voltage range V N -5 % % Current input at rated voltage (coil 20 C) 9 ma Max. switching voltage 25 AC Max. make current 20 A at 23 AC (50 ms) Max. continuous current 6 A Max. Switching power (resistive) 400A AC, resistance see load limit curve Recommended minimum load > 00 ma / 2 V AC/DC Operating power 400 mw Pull-in/drop-out/bounce time typ. 5 ms / 5 ms / - Nominal operating mode continuous duty Dielectric strength contact-coil 4 kv eff Surge capacity open contact kv eff Nominal voltage acc. to VDE 00 Part /4.97, IEC / 4 kv / 3 Mechanical life 0 x 0 6 switching operations Mechanical life at max. load (resistance) min switching operations Mechanical life at max. lamp load see "Lamp loads" table Signaling Isolated monitoring contact (B/B2 closed in automatic mode; max. A, 25 AC) Ambient operating temperature -25 C C Storage temperature -40 C C Dimensions (mm) W x H x L 7.5 x 55 x 90 Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP Cross sections 0.08 mm² mm² / AWG Stripped lengths mm / 0.22 in Standards/Specifications DIN VDE 060 EN 5078, degree of protection II

67 Relay Modules in DIN-Rail Mounted Enclosure 65 Relay with changeover contact ( u), manual-0-automatic switch with switch position monitoring Capability of different lamp loads: (switching operations acc. to EN 60669) Switching current (A) 00 0 AC resistive load DC resistive load Switching voltage (V) Type of load Capability Electrical life Incandescent lamp 2200 W Halogen lamp 23 AC 400 W Halogen trafo 2A Fluorescent lamp not comp., CB, cos ϕ 0,4-0,6 20 x 58 W Fluorescent lamp comp., Conv. ballast, C parallel 9 x 58 W Fluorescent lamp comp., Conv. ballast, Duo-circuit 600 W Fluorescent lamp with electronic ballast 2 x 58 W Energy saving lamp 5 W 25 pcs Energy saving lamp 3 W 30 pcs Energy saving lamp 9 W 38 pcs Gas discharge lamp 000 W Dulux-Lamp not compensated 800 W Dulux-Lamp compensated 500 W Max. capacitance at 23 AC 60 µf min Interface Modules Note:Inductive loads have to be attenuated by an appropriate protective circuit in order to protect relay coils and contacts! Description V N Relay modules in DIN-rail mounted enclosure, for DIN 35 rail A (24V) A3 B B3 A2 - A2 - A 0 A = Automatic (AUTO) 0 = OFF = Manual (MAN) 4 2 DC Accessories see Full Line Catalog 200/20 Volume 4 Contact material Ag alloy Input voltage range V N -5 % % Current input at rated voltage (coil 20 C) 9 ma Max. switching voltage 25 AC Max. make current 20 A at 23 AC (50 ms) Max. continuous current 2 A Max. Switching power (resistive) 400A AC, resistance see load limit curve Recommended minimum load > 00 ma / 2 V AC/DC Operating power 400 mw Pull-in/drop-out/bounce time typ. 5 ms / 5 ms / - Nominal operating mode continuous duty Dielectric strength contact-coil 4 kv eff Surge capacity open contact kv eff Nominal voltage acc. to VDE 00 Part /4.97, IEC / 4 kv / 3 Mechanical life 0 x 0 6 switching operations Mechanical life at max. load (resistance) min switching operations Mechanical life at max. lamp load see "Lamp loads" table Signaling Switch position monitoring (B = automatic, B3 = manual; max. A, DC) Ambient operating temperature -25 C C Storage temperature -40 C C Dimensions (mm) W x H x L 7.5 x 55 x 90 Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP Cross sections 0.08 mm² mm² / AWG Stripped lengths mm / 0.22 in Standards/Specifications DIN VDE 060 EN 5078, degree of protection II

68 Interface Module RS-232/SMI in DIN-Rail Mountable Enclosure For SMI drives, 23 AC Interface Modules TxD RxD GND 24 RS-232 I- I L N I- I PE Max. cable length 350 m brown blue gray black yellow/green L N I- I PE SMI drive ~ 230V L N I- I PE SMI drive ~ 230V L N I- I PE SMI drive ~ 230V The RS-232/SMI Interface Module is a standard interface for SMIcompliant electrical drives. The interface represents a purely physical level conversion between the standard RS-232 interface and the SMI signal level. The interface module operates up to 6 SMI drives, and the complete SMI range of functions can be used. The special WAGO-I/O-PRO function blocks communicate between applications and SMI drives. The modules support both single and group addressing, as well as status monitoring. Both 750 Series programmable fieldbus controllers' RS-232 onboard interfaces and / or / serial RS-232 interfaces can connect to the SMI Interface Module. The module must be supplied with an external 24VDC power source. RS-232 and 24V power supply are electrically isolated from the SMI connections. Description Interface module RS-232/SMI There is no electrical isolation between power supply and RS-232. The module is DIN-rail mountable. Notes on SMI: SMI stands for Standard Motor Interface, a standard interface for electrical drives. SMI was developed for connecting drives with integrated electronic circuitry for applications in shutters and sunshade systems. Voltage supply DC Voltage range ± 0 % Current consumption (internal) max. 55 ma Number of SMI channels Number of drives per channel 6 Operational indication LED green Interface RS-232 (interface input) Type of cable, cable length max. 350 m (SMI bus) max. 3 m (data and power supply cable, RS-232) Degree of protection IP20 Mounting position any Ambient operating temperature 0 C C Storage temperature -25 C C Dimensions (mm) W x H x L 35 x 55 x 90 Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP (WAGO 804 Series) Cross sections 0.5 mm² mm² / AWG Stripped lengths 0... mm / 0.42 in Approvals EN

69 Interface Module RS-232/SMI LoVo in DIN-Rail Mountable Enclosure For SMI drives, DC 67 TxD RxD GND 24V RS-232 LoV o I- I Interface Modules 24V 0V I- I Max. cable length 350 m 24V 24V 24V 0V SMI 0V SMI 0V SMI I- drive I- drive I- drive I 24V I 24V I 24V The RS-232/SMI LoVo Interface Module is a standard interface for SMI LoVo-compliant electrical drives. The interface represents a purely physical level conversion between the standard RS-232 interface and the SMI LoVo signal level. The interface module operates up to 6 SMI LoVo drives, and the complete SMI range of functions can be used. The special WAGO-I/O-PRO function blocks communicate between applications and SMI LoVo drives. The modules support both single and group addressing, as well as status monitoring. Both 750 Series programmable fieldbus controllers' RS-232 onboard interfaces and / or / serial RS-232 interfaces can connect to the SMI LoVo Interface Module. The module must be supplied with an external 24VDC power source. RS-232 and 24V power supply are electrically isolated from the SMI LoVo connections. Description Interface module RS-232/SMI LoVo There is no electrical isolation between power supply and RS-232. The module is DIN-rail mountable. Notes on SMI: SMI stands for Standard Motor Interface, a standard interface for electrical drives. SMI was developed for connecting drives with integrated electronic circuitry for applications in shutters and sunshade systems. Voltage supply DC Voltage range ± 0 % Current consumption (internal) max. 55 ma Number of SMI LoVo channels Number of drives per channel 6 Operational indication LED green Interface RS-232 (interface input) Type of cable, cable length max. 350 m (SMI bus) max. 3 m (data and power supply cable, RS-232) Degree of protection IP20 Mounting position any Ambient operating temperature 0 C C Storage temperature -25 C C Dimensions (mm) W x H x L 35 x 55 x 90 Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP (WAGO 804 Series) Cross sections 0.5 mm² mm² / AWG Stripped lengths 0... mm / 0.42 in Approvals EN

70 Current Sensor with Bus Connection in DIN-Rail Mountable Enclosure Measuring range A Interface Modules Digital Digital = Ix364, I/A Intelligent current sensor for monitoring solar plants or inverters for DC measurements within a large current measuring range. Description Current sensor with bus connection Accessories Accessories for data and auxiliary power supply RJ-45 interface module RJ-45 interface module with shield (screen) clamping saddle Approvals Conformity marking DIN EN 5078; EN ; EN General Specifications Dimensions (mm) W x H x L 35 x 55 x 90 Height from upper-edge of DIN 35 rail Ambient operating temperature -20 C C Storage temperature -40 C C Electrical data: Measuring range A DC Voltage supply 2 V V Max. current consumption 8 ma at Transmission error 0.5 % of upper range value (at room temperature) Temperature coefficient 0.0 % /K Time frame for polling by master < 30 ms Hot plugging possible Terminating resistor 50 Ω (can be activated via DIP switch ) Status indication Green: power Red: measured current < -3 A or > 83 A Mechanical data: Power cable feed-through 5 mm Degree of protection IP20 Communication: Interface RS-485 Transmission channels Half duplex 8-bit data, stop bit Protocols MODBUS over serial line Connector RJ-45 Addressing Max. length of bus line 200 m Baud rate 9,200 baud Parity Even

71 69 DIP Switch Adjustability: Pin Function Ub 2 3 n.c. 4 A (Data) 5 B (Data-) 6 n.c. 7 GND 8 RS-485 half duplex Uart: Communication settings required for transducer: Baud rate = 9200 bd Data bits = 8 Parity = Even Stop bits = Interface Modules Communication Description: MODBUS Function Read Holding Registers (0x03) Data Type Measurement Device Type 0x0000 Char Firmware 0x000 Char Errror Code 0x0002 Integer Measurement 0x0004 Integer Exception Code 0x0006 Integer Error Numbers: id Description Illegal Function Illegal Data Overflow (Current > 83 A) Underflow (Current < -3 A) DIP Switch Adjustability = ON Adress Dip Switch Terminating DIP switch resistor 2-50 Ohm NOTICE: 3 Only set the MODBUS address in the 32 OFF state.

72 / WINSTA Sunblind Box Bus Central Interface Modules S S2 S3 S4 S S ON DI P ON DI P DIP-Modul 2 DIP-Modul Jumper 4 3 S7 2 N M3 2 NC NC A B N GND NC M M 2 M N N N N M4 2 M M 2 M2 N N 23 N N L L The WINSTA Sunblind Box is a decentralized, stand-alone unit that controls 4 sunblind motors operated via standard switches. Output group configuration, operating time and "slat/sunblind" mode selection are performed via DIP switch. Operating the boxes in a network configuration provides extended functionality:. The sunblinds for all connected boxes are moved into the upper or end position via a central 24V control line. Either a weather station, a timer or a central switch enables this functionality. 2. The boxes also connect to a serial bus, allowing a higher-level control system to access up to 6 boxes connected to one bus segment. This operating mode addresses both individual channels and groups of boxes. Description WINSTA sunblind box / Supply: Voltage supply 23AC, 50 Hz Hz Voltage range ± 0 % Fuse protection Internal, glass cartridge fuse, accessible from outside Connection type () Socket with strain relief housing, 3-pole (item no ) Accessories 750 Series WAGO-I/O-Module RS-485 / configurable / Connector set for WINSTA sunblind box / The set includes: x socket with strain relief housing, 3-pole (item no ) 4 x plug with strain relief housing, 4-pole (item no ) x socket without strain relief housing, 4-pole (item no ) x strain relief housing, 4-pole (item no ) 4 x female connector, 3-pole (item no ) 4 x snap-on type strain relief housing (item no ) Configuration: Configuration Inputs: Number of inputs Signal voltage Transmission medium Connection type (2) via DIP switch/header 4 switch inputs for on-site switches 2 V Control line: J-Y (St) Y 2x2x0.6 mm 2, max. 0 m Female connector, 3-pole (item no ) Snap-on type strain relief housing h-distribution connector, bi-directional, plug - socket / socket

73 Connection type (2) Connection type (3) Connection type (4) Connection type (3) Connection type (3) Interface Modules Connection type (3) Connection type () 30 Motors: No. of outputs Switching voltage Switching current Switching power Connection type (3) Control: Operating mode Connection type (4) 4 power outputs (up, down, locked against each other) AC 23 x 6 A at 23 AC 300 W (AC3) Plug with strain relief housing, 4-pole (item no ) Bus control or central control via 24VDC signal Socket with strain relief housing, 4-pole (item no ) Strain relief housing, 4-pole (item no ) Standards and approvals: Conformity marking General specifications: Ambient operating temperature -5 C C Storage temperature -25 C C Dimensions (mm) W x H x L 200 x 45 x 30 Weight approx. 450 g Type of mounting Wall screw adapter Assembly Interior area, e.g., intermediate floors, suspended ceiling Mounting position any Degree of protection IP20 Degree of pollution 2 Housing material Polyamide (PA 6.6), flammability class UL94 V-0 Bus control: Data transmission Serial, master-slave procedure Baud rate 9,600 baud Bus interface Serial interface RS-485, max. 6 slaves Transmission medium Shielded bus cable: YCYM 2x2x0.8 mm 2, max. 800 m Central control via 24V signal: Operating voltage DC 0 % / -50 % Current consumption (internal) max. 5 ma Transmission medium Shielded bus cable: YCYM 2x2x0.8 mm 2

74 JUMPFLEX Transducers Universal Isolation Amplifier Interface Modules OUT OUT- Us GND 3 U I I I-/U IN U; I OUT U; I POWER 8 < 96 mm/3.76 in > < 94 mm/3.68 in > _> _> 6 mm/0.23 in Short description: The Universal Isolation Amplifier converts, amplifies and electrically isolates analog standard signals. The device has a 3-way isolation with a 2.5kV test voltage. In addition to standard signals, both unipolar and bipolar signals (± 0V, ± 20mA) up to 200V and 00mA can be set on the input side via DIP switches, which are accessible from the side of the housing. The analog output also supports standard unipolar and bipolar signals. Measurement range switching is calibrated. The device is supplied with 24VDC, which can be efficiently commoned using lateral push-in type jumper bars. A green LED on the front panel indicates normal operation. The isolation amplifier provides safe isolation of input, output and supply circuits with 2.5kV test voltage according to EN 640. A self-resetting fuse effectively protects the current input against overload. The fuse automatically resets when the overload is removed. Description Universal isolation amplifier Accessories General accessories see Full Line Catalog 200/20 Interface Modules Approvals Shipbuilding g (pending) 4 r ANSI/ISA (pending) Conformity marking General Specifications Dimensions (mm) W x H x L 6 x 96 x 94 Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm² mm² / AWG fine-stranded: 0.34 mm² mm² / AWG Stripped lengths mm / 0.37 in Ambient operating temperature -25 C C Storage temperature -40 C C Configuration DIP switch Input signal Voltage: ± 60 mv, 0 60 mv, ± 00 mv, 0 00 mv ± 50 mv, 0 50 mv, ± 300 mv, mv, ± 500 mv, mv, ± V, 0 V,± 5 V, V,... 5 V, ±, 0..., 2... ± 0, 0 0, ± 20, 0 20 Current: ± 0.3 ma, ma, ± ma, 0... ma,± 5 ma, ma,± 0 ma, ma, ma,± 20 ma, ma, ma,± 50 ma, ma,± 00 ma, ma Output signal Voltage: ±, 0..., 2..., ± 5 V, V,... 5 V Current: ± 20 ma, ma, ma, ± 0 ma, ma, ma Load impedance 600 Ω (I output) kω (U output) Max. operating frequency 00 Hz / > 5 khz (switchable via DIP switch) Voltage supply V N DC Supply voltage range 6.8 V V Transmission error < 0.08 % of upper range value Test voltage (input/output/supply) 2.5 kv AC, 50 Hz, min.

75 DIP Switch Adjustability = ON DIP Switch S Max. Operating Input Signal Ranges Zero/Span Adjustment Frequency Default setting* Inactive < 00 Hz 0 60 mv Active 5 khz ± 60 mv 0 00 mv ± 00 mv 0 50 mv ± 50 mv mv ± 300 mv mv ± 500 mv 0 V ± V 0 5 V ± 5 V 0 ± ± ± ± 20 DIP Switch S Input Signal Ranges ma ± 0.3 ma 0 ma ± ma 0 5 ma ± 5mA 0 0 ma ± 0 ma 0 20 ma ± 20 ma 0 50 ma ± 50 ma 0 00 ma ± 00 ma 5 V ma 4 20 ma 3 73 Interface Modules DIP Switch S2 Output Signal Ranges Reserve Clipping Rocker Switch Lock Default setting* 0 ± V ± 5 V 5 V 0 20 ma ± 20 ma 4 20 ma 0 0 ma ± 0 ma 2 0 ma inactive (analog response) active (limiting response) switched off switched on *Default setting Input ± Output ± Max. operating frequency > 5 khz * The input and output range DIP switches must be readjusted when changing the default setting.

76 , , , , , JUMPFLEX Transducers Isolation amplifiers, fixed setting for voltage or current signals Interface Modules IN GND Us GND IN POWER OUT OUT GND 2 Us GND 3 < 96 mm/3.76 in > < 94 mm/3.68 in > _> _> 6 mm/0.23 in Short description: The configurable isolation amplifiers convert, amplify, filter and electrically isolate analog standard signals. The devices have a 3-way isolation with a 2.5kV test voltage. The Isolation Amplifier provides electrical isolation between the 0(4) - 20mA input and the 0(4) - 20mA output analog current signals. The Isolation Amplifier provides electrical isolation between the 0(2) - 0V input and the 0(2) - 0V output analog voltage signals. The device is supplied with 24VDC, which can be quickly and cost-effectively commoned via lateral, push-in type jumper bars. A green LED on the front panel indicates normal operation. The isolation amplifiers meet the requirements for safe isolation of input, output and supply circuits with 2.5kV test voltage according to EN 640. Description Input signal Output signal Isolation amplifier 0(4) ma 0(4) ma Isolation amplifier 0(2)... 0(2) Isolation amplifier ma Isolation amplifier ma Isolation amplifier ma Isolation amplifier ma Accessories General accessories see Full Line Catalog 200/20 Interface Modules Approvals Shipbuilding g 4 r ANSI/ISA Class I, Div. 2, Grp. ABCD, T4 Conformity marking General Specifications Dimensions (mm) W x H x L 6 x 96 x 94 Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm² mm² / AWG fine-stranded: 0.34 mm² mm² / AWG Stripped lengths mm / 0.37 in Dimensions (mm) W x H x L 6 x 96 x 94 Input signal 857-4: 0(4) ma : 0(2) : : : ma : ma Input resistance 50 Ω (I input) 00 kω (U input) Output signal 857-4: 0(4) ma 857-4: 0(2) : ma 857-4: ma 857-4: : 0... Load impedance 600 Ω (I output) 2 kω (U output) Max. operating frequency 00 Hz Response time (T 0-90 ) < 3.5 ms Voltage supply V N DC Supply voltage range 6.8 V V Current consumption at DC < 25 ma Transmission error < 0. % of the full scale value Temperature coefficient 0.0 % /K Test voltage (input/output/supply) 2.5 kv AC, 50 Hz, min Ambient operating temperature -25 C C Storage temperature -40 C C

77 3 75 Interface Modules

78 JUMPFLEX Transducers Ni Transducer for Ni 00, Ni 20, Ni 200, Ni 500, Ni 000 Interface Modules IN 5 OUT 6 7 POWER 8 OUT GND Us GND 2 < 96 mm/3.76 in > < 94 mm/3.68 in > _> _> 6 mm/0.23 in Short description: The Ni Transducer (Ni = nickel) is ideal for standardized Ni sensors. On the output side, the Ni temperature transducer converts the temperature signal into an analog standard signal. The following signals are available: 0-20mA, 4-20mA, 0-0V, 2-0V, 0-5V, - 5V, 0-0mA and 2-0mA. The device has a 3-way isolation with a 2.5kV test voltage. It is configurable via DIP switches, which are accessible from the side of the housing. The device is supplied with 24VDC, which can be efficiently commoned using lateral push-in type jumper bars. A green LED on the front panel indicates normal operation. The temperature transducer provides safe isolation of input, output and supply circuits with 2.5kV test voltage according to EN 640. Description Ni transducer for Ni 00, Ni 20, Ni 200, Ni 500, Ni 000 with temperature coefficients: 678 ppm/k (DIN 43760) 5000 ppm/k; 6720 ppm/k; 6370 ppm/k Accessories General accessories see Full Line Catalog 200/20 Interface Modules Approvals Shipbuilding g (pending) 4 r ANSI/ISA (pending) Conformity marking Configuration DIP switch Input signal Ni sensors Max. input signal ± 3.2 V DC Output signal ma, ma, 0..., 2..., V,... 5 V, ma, ma Load impedance 600 Ω (Out = ma) 2 kω (Out = V) Step response < 60 ms at 2- and 4-conductor measurement Voltage supply V N DC Supply voltage range 6.8 V V Sensor types Ni 00, Ni 20, Ni 200, Ni 500, Ni 000 Sensor connection 2-wire, 3-wire, 4-wire (switchable) Transmission error 0. % of upper range value Test voltage (input/output/supply) 2.5 kv AC, 50 Hz, min. General Specifications Dimensions (mm) W x H x L 6 x 96 x 94 Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm² mm² / AWG fine-stranded: 0.34 mm² mm² / AWG Stripped lengths mm / 0.37 in Ambient operating temperature -25 C C Storage temperature -40 C C

79 DIP Switch Adjustability = ON DIP Switch S Connection Technology Temperature Coefficient Sensor Type conductor 678 ppm/k Ni 00 3-conductor 5000 ppm/k Ni 20 4-conductor 6720 ppm/k Ni 200 Reserve Ni 500 Ni 000 DIP Switch S Interface Modules Start Temperature End Temperature C T / C T / C T / C DIP Switch S2 Output Signal Measuring Range Underflow Measuring Range Overflow Wire Break Short Circuit 0 20 ma Lower limit of output range 4 20 ma -5 % * Upper limit of output range 2.5 % Upper limit of output range 5 % Lower limit of output range -2.5 % * 0 0 ma Upper limit of output range Lower limit of output range 2 0 ma 2.5 % 0 Upper limit of output Lower limit of output range 2 range 0 5 V Upper limit of output Lower limit of output range 5 V range Upper limit of output range 5 % Upper limit of output range 5 % Lower limit of output range Lower limit of output range Upper limit of output range 5 % Lower limit of output range * but not when lower limit of output range = 0V or 0mA Default Setting All DIP switches are in OFF position for delivery. Sensor connection 2-conductor Sensor type NI 00 Temperature coeffi cient 678 ppm/k Start temperature 0 C End temperature 00 C Output signal 0 20 ma Measuring range underfl ow 0 ma Measuring range overfl ow 20.5 ma Wire break 2 ma Short circuit 0 ma

80 JUMPFLEX Transducers KTY Transducer Interface Modules IN IN- DO GND 2 KTY 2 3 DO 4 OUT U; I POWER 8 OUT GND Us GND 2 < 96 mm/3.76 in > < 94 mm/3.68 in > _> _> 6 mm/0.23 in Short description: The KTY Transducer is ideal for standardized KTY sensors. On the output side, the KTY temperature transducer converts the temperature signal into an analog standard signal. The following signals are available: 0-20mA, 4-20mA, 0-0V, 2-0V, 0-5V, - 5V, 0-0mA and 2-0mA. The device has a 3-way isolation with a 2.5kV test voltage. It is configurable via DIP switches, which are accessible from the side of the housing. The device is supplied with 24VDC, which can be efficiently commoned using lateral push-in type jumper bars. A green LED on the front panel indicates normal operation. The temperature transducer provides safe isolation of input, output and supply circuits with 2.5kV test voltage according to EN 640. Description KTY Transducer Accessories General accessories see Full Line Catalog 200/20 Interface Modules Approvals Shipbuilding g (pending) 4 r ANSI/ISA (pending) Conformity marking General Specifications Dimensions (mm) W x H x L 6 x 96 x 94 Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm² mm² / AWG fine-stranded: 0.34 mm² mm² / AWG Stripped lengths mm / 0.37 in Ambient operating temperature -25 C C Storage temperature -40 C C Configuration DIP switch Input signal KTY sensors Max. input signal ± 3 DC Output signal ma, ma, 0..., 2..., V,... 5 V, ma, ma Load impedance 600 Ω (Out = ma) 2 kω (Out = V) Step response < 50 ms Voltage supply V N DC Supply voltage range 6.8 V V Sensor types KTY8-0, KTY8-20, KTY8-50 KTY82-0, KTY82-20, KTY82-50, KTY8-2, KTY82-2, KTY8-22, KTY82-22, KTY8-20, KTY8-220, KTY82-20, KTY82-220, KTY8-22, KTY82-22, KTY8-222, KTY82-222, KTY8-250, KTY82-250, KTY83-0, KTY83-20, KTY83-50, KTY83-2, KTY83-22, KTY83-5, KTY84-30, KTY84-50, KTY84-5, KTY6, KTY9, ST3, ST20 Sensor connection 2-conductor Transmission error 0. % of upper range value Test voltage (input/output/supply) 2.5 kv AC, 50 Hz, min.

81 DIP Switch Adjustability = ON DIP Switch S Sensor Type KTY8-0, KTY8-20, KTY82-0, KTY82-20 KTY8-2, KTY82-2 KTY8-22, KTY82-22 KTY8-50, KTY82-50 KTY8-20, KTY8-220, KTY82-20, KTY KTY8-22, KTY82-22 KTY8-222, KTY KTY8-250, KTY KTY83-0, KTY83-20, KTY83-2 KTY83-22 KTY83-50 KTY83-5 KTY84-30, KTY84-50 KTY84-5 KTY6, KTY9, ST3, ST20 Interface Modules DIP Switch S2 Start Temperature End Temperature 2 3 C C C C DIP Switch S Output Signal Measuring Range Underflow Measuring Range Overflow Wire Break Short Circuit 0 20 ma E Lower limit of output range 4 20 ma F -5 % * Upper limit of output range 2.5 % Upper limit of output range 5 % Lower limit of output range -2.5 % * 0 0 ma G Upper limit of output range Lower limit of output range 2 0 ma H 2.5 % 0 J 2 K 0 5 V L 5 V M Lower limit of output range Lower limit of output range Upper limit of output range Upper limit of output range Upper limit of output range 5 % Upper limit of output range 5 % Lower limit of output range Lower limit of output range Upper limit of output range 5 % Lower limit of output range * but not when lower limit of output range = 0V or 0mA Default Setting All DIP switches are in OFF position for delivery. Sensor type KTY8-0, KTY8-20, KTY82-0, KTY82-20 Start temperature 0 C End temperature 00 C Output signal 0 20 ma Measuring range underfl ow 0 ma Measuring range overfl ow 20.5 ma Wire break 2 ma Short circuit 0 ma Digital output not active DIP Switch S2 9 0 Digit Output DO Signaling DO not active DO Us switching DO GND switching

82 JUMPFLEX Supply and Through Module Supply and Through Module Signal 5 Signal Interface Modules GND Us GND GND Us GND < 96 mm/3.76 in > < 94 mm/3.68 in > _> _> 6 mm/0.23 in Short description: The Supply and Through Module transmits electrically isolated signals, e.g. in conjunction with the JUMPFLEX Interface Adapter, for analog signals. When used as a through module, it transmits the power from the connected clamping points to the adjacent JUMPFLEX modules via push-in type jumper bars. Description Supply and through module Accessories General accessories see Full Line Catalog 200/20 Interface Modules Max. voltage Current carrying capacity Contact resistance 33 V AC/DC 8 A < 0 mω Approvals r UL 508 (pending) Shipbuilding g (pending) Conformity marking General Specifications Dimensions (mm) W x H x L 6 x 96 x 94 Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm² mm² / AWG fine-stranded: 0.34 mm² mm² / AWG Stripped lengths mm / 0.37 in Ambient operating temperature -25 C C Storage temperature -40 C C

83 3 8 Interface Modules

84 JUMPFLEX Transducers Frequency transducer 0. Hz khz Interface Modules 8,2V(Namur) f IN GND NPN/PNP IN f OUT U, I POWER 8 OUT GND 2 Us GND 3 Short description: The frequency transducer collects 0. Hz - 20 khz signals from NAMUR, NPN or PNP sensors and converts them into an analog standard signal. This standard signal can be set to 0-20 ma, 4-20 ma, 0-0 ma, 2-0 ma, 0 -, 2 -, 0-5 V or - 5 V. The devices are configurable either via FDT/DTM configuration tool or via DIP switches, which are accessible from the side of the housing. Measurement range switching is calibrated. The device is supplied with 24VDC, which can be efficiently commoned using lateral, push-in type jumper bars. A green LED on the front panel indicates normal operation. The frequency transducer provides safe isolation of input, output and supply circuits with 2.5kV test voltage according to EN 640. Description Frequency transducer Accessories General Approvals see Full Line Catalog 200/20 Interface Modules Shipbuilding g (pending) 4 r ANSI/ISA (pending) Conformity marking System Data Configuration DIP switch Sensor types -Frequency generators -NAMUR sensors -NPN/PNP transistor outputs without pull-up or pull-down resistor -mech. contact (dry contact) Output signal Voltage: 0..., 2..., V,... 5 V Current: ma, ma, ma, ma Load impedance 600 Ω (I output) 2 kω (U output) Conversion time Gate time measurement principle: < 20 ms Pulse measurement method: < 200 μs Voltage supply V N DC Supply voltage range 6.8 V V Current consumption at DC < 40 ma Transmission error < 0. % of upper range value Temperature coefficient 0.0 % /K Test voltage (input/output/supply) 2.5 kv AC, 50 Hz, min. Refer to following pages for DIP Switch Table, Pin Assignments and other technical data.

85 < 96 mm/3.76 in > < 94 mm/3.68 in > _> _> 6 mm/0.23 in Interface Modules General Specifications Input for frequency generators or NPN/PNP transistor outputs with pull-up or pull-down resistor Frequency range 0. Hz khz Signal level.5 V,, 2 (switchable) Max. input signal ± DC 3.2 V Pulse length μs Signal form Any Coupling AC/DC (AC above 0 Hz) (adjustable) Min. measuring span 0 Hz Input resistance 0 kω General Specifications Dimensions (mm) W x H x L 6 x 96 x 94 Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm² mm² / AWG fine-stranded: 0.34 mm² mm² / AWG Stripped lengths mm / 0.37 in Ambient operating temperature -25 C C Storage temperature -40 C C Input for NAMUR sensors per DIN EN Sensor supply DC 8.2 V Signal current (0).2 ma Signal current () 2. ma Hysteresis 0.45 ma Input resistance < 600 Ω Frequency range 0. Hz... khz Pulse length 500 μs Min. measuring span 0 Hz Short-circuit current 4 ma Short circuit monitoring > 4.7 ma Wire break monitoring < 0.2 ma Input for NPN/PNP transistor outputs without pull-up or pull-down resistor or mech. contact (dry contact) Frequency range 0. Hz khz Pulse length 25 μs Min. measuring span 0 Hz Open-circuit voltage DC 5 V NPN_Residual voltage <.5 V PNP Switching voltage > 7.5 V residual voltage U CE sat

86 3 84 DIP Switch Adjustability DIP Switch S = ON Operation with disturbed frequency signals for acceptable signal level Source Input Coupling (applies only to f IN input) Interface Modules Frequency generator or NPN/PNP transistor outputs with pull-up or pull-down resistor AC/DC High Low NAMUR AC (without DC), see Figure >.5 V < 0.4 V NPN/PNP transistor outputs without pull-up or pull-down resistor input > < 8 V Dry Contact > 2 <6 V >.5 V < 0.4 V DIP Switch S DIP Switch S2 Input Input Frequency/Hz Frequency/Hz Start Value End Value Default Setting Input: Input source U Figure : Coupling AC/DC AC Frequency generator/transistor output with pull-up or pull-down resistor AC/DC Coupling Signal level >.5V Start value 00 Hz End value 000 Hz Measuring technique Gate time measurement method Output: Output signal Current Start value 0 ma End value 20 ma Measuring range underfl ow 0 ma Measuring range overfl ow 20.5 ma t DIP Switch S2 Output Signal Measuring Range Measuring Range Only for NAMUR Sensors Underflow Overflow Wire Break Short Circuit 0 20 ma Lower limit of output range* Upper limit of output range* Upper limit of output range* Lower limit of output range * 4 20 ma -5 % 2.5 % 5 % -2.5 % 0 0 ma Upper limit of output range Upper limit of output range Lower limit of output range 2 0 ma 2.5 % 5 % Lower limit of output range 0 Upper limit of output range Upper limit of output range Lower limit of output range Upper limit of output range 2 5 % 5 % 0 5 V 5 V Lower limit of output range Upper limit of output range Lower limit of output range Lower limit of output range *acc. to NAMUR NE 43

87 , Wiring Material 2-Conductor DC (Mechanical Contact) 2-Conductor DC NAMUR Sensor 3 85 BN BN BU IN OUT POWER BU IN OUT POWER Interface Modules NPN Transistor Output NPN Transistor Output with Pull-Up Resistor BN OUT R BN BK OUT BK BU IN BU IN POWER POWER PNP Transistor Output PNP Transistor Output with Pull-Down Resistor BN OUT BN BK OUT BK R BU IN BU IN POWER POWER Frequency Generator OUT IN POWER

88 JUMPFLEX Transducers Current transducer AC/DC 0... A, A Interface Modules IN A (GND ) IN 5A (GND ) DO (GND 3) GND IN 2 3 DO 4 5 OUT 6 7 POWER 8 OUT GND 2 Us GND 3 < 96 mm/3.76 in > < 94 mm/3.68 in > _> _> 6 mm/0.23 in Short description: The current transducer collects the following AC and DC currents: 0 - A AC/DC and 0-5 A AC/DC. Both sinusoidal and non-sinusoidal signals (true RMS measurement) can be collected. On the output side, the current transducer converts these signals into an analog standard signal. This standard signal can be set to 0-20 ma, 4-20 ma, 0-0 ma, 2-0 ma, 0 -, 2 -, 0-5 V or - 5 V. The devices are configurable either via FDT/DTM configuration tool or via DIP switches, which are accessible from the side of the housing. Measurement range switching is calibrated. A digital switching output is available that can also be configured using FDT/DTM configuration tool. Description Current transducer Accessories General accessories see Full Line Catalog 200/20 Interface Modules Approvals Shipbuilding g (pending) 4 r ANSI/ISA (pending) Conformity marking General Specifications Dimensions (mm) W x H x L 6 x 96 x 94 Height from upper-edge of DIN 35 rail Wire connection CAGE CLAMP S Cross sections solid: 0.08 mm² mm² / AWG fine-stranded: 0.34 mm² mm² / AWG Stripped lengths mm / 0.37 in Ambient operating temperature -25 C C Storage temperature -40 C C The device is supplied with 24VDC, which can be efficiently commoned using lateral push-in type jumper bars. A green LED on the front panel indicates normal operation. The current transducer provides safe isolation of input, output and supply circuits with 2.5kV test voltage according to EN 640. Configuration DIP switch or FDT/DTM configuration tool Input signal 0... A AC/DC; A AC/DC Input resistance 0 mω (5 A); 47 mω ( A) Frequency range 30 Hz Hz Output signal Voltage: 0..., 2..., V,... 5 V Current: ma, ma, ma, ma Load impedance 600 Ω (I output)** 2 kω (U output) Measuring procedure Arithmetic mean value True RMS measurement Signal mapping Response time.5 ms Signal cycle duration Max. response time 30 ms Voltage supply V N DC Supply voltage range 6.8 V V Current consumption at DC < 40 ma Transmission error < 0. % typ. (< 0.2 % max.) Temperature coefficient 0.0 % /K Min. measuring span 2 ma... A; 4 ma... 5 A Test voltage (input/output/supply) 2.5 kv AC, 50 Hz, min. Output - Digital Min. measuring span 2 ma... A; 4 ma... 5 A Max. continuous current 500 ma (up to 60 C) 00 ma (60 C C) ( * Additional setting options are possible via FDT-/DTM configuration tool.) **Operating restrictions may occur within the temperature range

89 DIP Switch Adjustability = ON DIP Switch S 3 87 Input Signal Measuring Method Output Signal A Mean square value ma A Arithmetic mean value ma Signal mapping 0... Absolute value measurement ma ma V... 5 V Interface Modules DIP Switch S Overcurrent Measuring Range Underflow Measuring Range Overflow 7 8 (Input Signal - End Value 20%) 9 0 Lower limit of measuring range - 5 % Upper limit of measuring range 2.5 % Upper limit of measuring range 5 % Digit Output DO Signaling DO not active Lower limit of measuring range Upper limit of measuring range 2.5 % Upper limit of measuring range 5 % DO Us switching Lower limit of measuring range Upper limit of measuring range Lower limit of measuring range DO GND switching Lower limit of measuring range Upper limit of measuring range Upper limit of measuring range

90 4 88 Primary Switch Mode Power Supply EPSITRON COMPACT Power Interface Modules L N DC DC DC - DC - Description Description Primary switch mode power supply unit Prepared for class II equipment Natural convection cooling when horizontally mounted Stage profile, ideal for distribution boards or distribution boxes Primary Switch Mode Power Supply, 2 V DC / 2 A Input: Environmental requirements: Nominal input voltage Vi nom AC Ambient operating temperature -25 C C Input voltage range 85 V V AC; V DC Storage temperature -25 C C Input voltage derating < 0 AC: Ia max..5 A Rel. humidity 30 % % (no condensation) Frequency 44 Hz Hz: 0 Hz Derating -3 % / K (> 45 C) Input current Ii 0.6 A at AC / 0.4 A at 23 AC Degree of pollution 2 (acc. to EN 5078) Discharge current ma typ. Climatic category 3K3 (acc. to EN 6072) Inrush current < 30 A, NTC Safety and protection: Mains failure hold-up time > 0 ms at AC / > 80 ms at 23 AC Enclosure Plastic, light gray, Flammability class V0 acc. to UL94 Output: Test voltage pri. - sec. 4.2 kv Nominal output voltage Vo nom 2 V DC Protection class Prepared for class II equipment Output voltage range 0.8 V... 8 V DC adjustable Degree of protection IP20 (acc. to EN 60529) Output current Io 2A at 2V DC Overvoltage protection < 30V DC (in the event of a fault) 0.75A at 8V DC Short circuit protection yes max..4a (2 V DC) in any mounting No-load proof yes position Feedback voltage max. 2 DC Factory preset 2 V DC Parallel operation yes Adjustment accuracy 2 % Series connection yes Residual ripple < 50 mvpp at 20 MHz Connection and type of mounting: Current limitation. x Io typ. Wire connection Input/Output: WAGO 740 Series / Overload behavior Constant current WAGO 740 Series Operational indication LED green (Va) Cross sections Input: 0.08 mm² mm² / Efficiency / power losses: Efficiency 80 % typ. AWG Output: 0.08 mm² mm² / Power loss P V 3 W (no load) / 6 W (rated load) Stripped lengths AWG Input: mm / in Max. power loss P V 6 W typ. (0 AC / 2 V DC, 2 A) Output: mm / in Fuse protection: Type of mounting DIN-rail mount (EN 6075) Internal fuse 2 AT Dimensions and weight: External fuse Wire breaking 0A, 6A, Characteristic B, C An external DC fuse is required for the Dimensions (mm) W x H x L 54 x 59 x 89 Height: 55mm, from upper-edge of DIN 35 rail DC input voltage Weight approx. 80 g Standards and approvals: Standards/Specifications EN (SELV), EN (PELV), EN , UL 60950, UL 508

91 Primary Switch Mode Power Supply EPSITRON COMPACT Power 4 89 L N DC DC DC - DC - Interface Modules Description Description Primary switch mode power supply unit Prepared for class II equipment Natural convection cooling when horizontally mounted Stage profile, ideal for distribution boards or distribution boxes Primary Switch Mode Power Supply, 2 V DC / 4 A Input: Environmental requirements: Nominal input voltage Vi nom AC Ambient operating temperature -25 C C Input voltage range 85 V V AC; V DC Storage temperature -25 C C Input voltage derating < 0 AC: Ia max. 3.5 A Rel. humidity 30 % % (no condensation) Frequency 44 Hz Hz: 0 Hz Derating -3 % / K (> 45 C) Input current Ii 0.9 A at AC / 0.5 A at 23 AC Degree of pollution 2 (acc. to EN 5078) Discharge current ma typ. Climatic category 3K3 (acc. to EN 6072) Inrush current < 30 A, NTC Safety and protection: Mains failure hold-up time > 0 ms at AC / > 80 ms at 23 AC Enclosure Plastic, light gray, Flammability class V0 acc. to UL94 Output: Test voltage pri. - sec. 4.2 kv Nominal output voltage Vo nom 2 V DC Protection class Prepared for class II equipment Output voltage range 0.5 V V DC adjustable Degree of protection IP20 (acc. to EN 60529) Output current Io 4A at 2V DC Overvoltage protection < 30V DC (in the event of a fault) max. 2.4A in any mounting position Short circuit protection yes Factory preset 2 V DC No-load proof yes Adjustment accuracy 2 % Feedback voltage max. 2 DC Residual ripple < 00 mvpp at 20 MHz Parallel operation yes Current limitation. x Io typ. Series connection yes Overload behavior Constant current Connection and type of mounting: Operational indication LED green (Va) Wire connection Input/Output: WAGO 740 Series / Efficiency / power losses: WAGO 740 Series Efficiency 85 % typ. Cross sections Input: 0.08 mm² mm² / Power loss P V 2.5 W (no load) / 9 W (rated load) AWG Output: 0.08 mm² mm² / Max. power loss P V 9 W typ. (0 AC / 2 V DC, 4 A) AWG Fuse protection: Stripped lengths Input: mm / in Internal fuse 2 AT Output: mm / in External fuse Wire breaking 0A, 6A, Characteristic B, C An external DC fuse is required for the DC input voltage Type of mounting DIN-rail mount (EN 6075) Dimensions and weight: Dimensions (mm) W x H x L 72 x 59 x 89 Height: 55mm, from upper-edge of DIN 35 rail Weight approx. 255 g Standards and approvals: Standards/Specifications EN (SELV), EN (PELV), EN , UL 60950*, UL 508* (* pending)

92 4 90 Primary Switch Mode Power Supply EPSITRON COMPACT Power Interface Modules L N DC DC DC - DC - Description Description Primary switch mode power supply unit Prepared for class II equipment Natural convection cooling when horizontally mounted Stage profile, ideal for distribution boards or distribution boxes Primary Switch Mode Power Supply, DC /.3 A Input: Environmental requirements: Nominal input voltage Vi nom AC Ambient operating temperature -25 C C Input voltage range 85 V V AC; V DC Storage temperature -25 C C Input voltage derating < 0 AC: Ia max. A Rel. humidity 30 % % (no condensation) Frequency 44 Hz Hz: 0 Hz Derating -3 % / K (> 45 C) Input current Ii 0.7 A at AC / 0.5 A at 23 AC Degree of pollution 2 (acc. to EN 5078) Discharge current ma typ. Climatic category 3K3 (acc. to EN 6072) Inrush current < 30 A, NTC Safety and protection: Mains failure hold-up time > 0 ms at AC / > 80 ms at 23 AC Enclosure Plastic, light gray, Flammability class V0 acc. to UL94 Output: Test voltage pri. - sec. 4.2 kv Nominal output voltage Vo nom DC Protection class Prepared for class II equipment Output voltage range 22.8 V V DC adjustable Degree of protection IP20 (acc. to EN 60529) Output current Io.3A at 24V DC Overvoltage protection < 40V DC (in the event of a fault) max. 0.9A in any mounting position Short circuit protection yes Factory preset DC No-load proof yes Adjustment accuracy 2 % Feedback voltage max. 3 DC Residual ripple < 00 mvpp at 20 MHz Parallel operation yes Current limitation. x Io typ. Series connection yes Overload behavior Constant current Connection and type of mounting: Operational indication LED green (Va) Wire connection Input/Output: WAGO 740 Series / Efficiency / power losses: WAGO 740 Series Efficiency 82 % typ. Cross sections Input: 0.08 mm² mm² / Power loss P V 3 W (no load) / 7.3 W (rated load) AWG Output: 0.08 mm² mm² / Max. power loss P V 7.3 W typ. (0 AC / DC,.3 A) AWG Fuse protection: Stripped lengths Input: mm / in Internal fuse 2 AT Output: mm / in External fuse Wire breaking 0A, 6A, Characteristic B, C An external DC fuse is required for the DC input voltage Type of mounting DIN-rail mount (EN 6075) Dimensions and weight: Dimensions (mm) W x H x L 54 x 59 x 89 Height: 55mm, from upper-edge of DIN 35 rail Weight approx. 80 g Standards and approvals: Standards/Specifications EN (SELV), EN (PELV), EN , UL 60950, UL 508

93 Primary Switch Mode Power Supply EPSITRON COMPACT Power 4 9 L N DC DC DC - DC - Interface Modules Description Description Primary switch mode power supply unit Prepared for class II equipment Natural convection cooling when horizontally mounted Stage profile, ideal for distribution boards or distribution boxes Primary Switch Mode Power Supply, DC / 2.5 A Input: Environmental requirements: Nominal input voltage Vi nom AC Ambient operating temperature -25 C C Input voltage range 85 V V AC; V DC Storage temperature -25 C C Input voltage derating < 0 AC: Ia max. 2.0 A Rel. humidity 30 % % (no condensation) < 9 AC: Ia max..8 A Derating -3 % / K (> 45 C) Frequency 44 Hz Hz: 0 Hz Degree of pollution 2 (acc. to EN 5078) Input current Ii.4 A at AC / 0.6 A at 23 AC Climatic category 3K3 (acc. to EN 6072) Discharge current ma typ. Safety and protection: Inrush current < 30 A, NTC Enclosure Plastic, light gray, Mains failure hold-up time > 0 ms at AC / Flammability class V0 acc. to UL94 > 80 ms at 23 AC Test voltage pri. - sec. 4.2 kv Output: Protection class Prepared for class II equipment Nominal output voltage Vo nom DC Degree of protection IP20 (acc. to EN 60529) Output voltage range 22.8 V V DC adjustable Overvoltage protection < 40V DC (in the event of a fault) Output current Io 2.5A at 24V DC Short circuit protection yes max..6a in any mounting position No-load proof yes Factory preset DC Feedback voltage max. 3 DC Adjustment accuracy 2 % Parallel operation yes Residual ripple < 00 mvpp at 20 MHz Series connection yes Current limitation. x Io typ. Connection and type of mounting: Overload behavior Constant current Wire connection Input/Output: WAGO 740 Series / Operational indication LED green (Va) WAGO 740 Series Efficiency / power losses: Cross sections Input: 0.08 mm² mm² / Efficiency 88 % typ. AWG Power loss P V 2.5 W (no load) / 0.5 W (rated load) Output: 0.08 mm² mm² / AWG Max. power loss P V 0.5 W typ. (0 AC / DC, 2.5 A) Stripped lengths Input: mm / in Fuse protection: Output: mm / in Internal fuse 2 AT Type of mounting DIN-rail mount (EN 6075) External fuse Wire breaking 0A, 6A, Characteristic B, C An external DC fuse is required for the DC input voltage Dimensions and weight: Dimensions (mm) W x H x L 72 x 59 x 89 Height: 55mm, from upper-edge of DIN 35 rail Weight approx. 255 g Standards and approvals: Standards/Specifications EN (SELV), EN (PELV), EN , UL 60950, UL 508

94 4 92 Primary Switch Mode Power Supply EPSITRON COMPACT Power Interface Modules L N DC DC DC - DC - Description Description Primary switch mode power supply unit Prepared for class II equipment Natural convection cooling when horizontally mounted Stage profile, ideal for distribution boards or distribution boxes Primary Switch Mode Power Supply, DC / 4 A Input: Environmental requirements: Nominal input voltage Vi nom AC Ambient operating temperature -25 C C Input voltage range 85 V V AC; V DC Storage temperature -25 C C Input voltage derating on request Rel. humidity 30 % % (no condensation) Frequency 44 Hz Hz: 0 Hz Derating -3 % / K (> 45 C) Input current Ii.6 A at AC / 0.9 A at 23 AC Degree of pollution 2 (acc. to EN 5078) Discharge current ma typ. Climatic category 3K3 (acc. to EN 6072) Inrush current < 30 A, NTC Safety and protection: Mains failure hold-up time > 5 ms at AC / > 00 ms at 23 AC Enclosure Plastic, light gray, Flammability class V0 acc. to UL94 Output: Test voltage pri. - sec. 4.2 kv Nominal output voltage Vo nom DC Protection class Prepared for class II equipment Output voltage range 22.8 V V DC adjustable Degree of protection IP20 (acc. to EN 60529) Output current Io 4A at 24V DC Overvoltage protection < 40V DC (in the event of a fault) max. 2.4A in any mounting position Short circuit protection yes Factory preset DC No-load proof yes Adjustment accuracy 2 % Feedback voltage max. 3 DC Residual ripple < 00 mvpp at 20 MHz Parallel operation yes Current limitation. x Io typ. Series connection yes Overload behavior Constant current Connection and type of mounting: Operational indication LED green (Va) Wire connection Input/Output: WAGO 740 Series / Efficiency / power losses: WAGO 740 Series Efficiency 88 % typ. Cross sections Input: 0.08 mm² mm² / Power loss P V < W (no load) / 4.8 W (rated load) AWG Output: 0.08 mm² mm² / Max. power loss P V 4.8 W typ. (264 V AC / DC, 6 A) AWG Fuse protection: Stripped lengths Input: mm / in Internal fuse 4 AT Output: mm / in External fuse Wire breaking 0A, 6A, Characteristic B, C An external DC fuse is required for the DC input voltage Type of mounting DIN-rail mount (EN 6075) Dimensions and weight: Dimensions (mm) W x H x L 90 x 59 x 89 Height: 55mm, from upper-edge of DIN 35 rail Weight approx. 30 g Standards and approvals: Standards/Specifications EN (SELV), EN (PELV), EN , UL 60950*, UL 508* (* pending)

95 Primary Switch Mode Power Supply EPSITRON - PRO - Power 4 93 L N Stand-by DC O.K. DC DC DC - DC - Interface Modules Description Description Primary switch mode power supply with PowerBoost and TopBoost Stand-by input for switching off the output and minimizing power consumption Prepared for class I equipment Natural convection cooling when horizontally mounted Enclosed for use in switchgear cabinets Parallel operation, series connection possible Primary Switch Mode Power Supply, 2 V DC / 6 A Input: Environmental requirements: Nominal input voltage Vi nom /2 x AC Ambient operating temperature -0 C C Input voltage range 85 V V AC; DC Storage temperature -25 C C (use of DC requires external protection) Rel. humidity 30 % % (no condensation) Input voltage derating -5 % / V AC < AC 95 V Derating -3 % / K (>50 C) Frequency 50 Hz Hz Degree of pollution 2 (acc. to EN 5078) Input current Ii 0.5 A at 23 AC and 6 A DC Climatic category 3K3 (acc. to EN 6072) Discharge current ma typ. Safety and protection: Inrush current < 5 Ap Test voltage pri. - sec. 4.2 kv Mains failure hold-up time 70 ms typ. at 23 AC Protection class Prepared for class I equipment Output: Degree of protection IP20 (acc. to EN 60529) Nominal output voltage Vo nom 2 V DC, SELV Overvoltage protection Varistor at primary circuit Output voltage range V... 8 V DC adjustable Short circuit protection yes Output current Io 6 A at 2 V DC No-load proof yes PowerBoost 2 A DC (for 4 s); 9 A DC (for 8 s) Feedback voltage max. 25 V DC TopBoost 2 A DC (for 25 ms) Parallel operation yes Factory preset 2 V DC Series connection yes Adjustment accuracy % Connection and type of mounting: Residual ripple < 70 mvpp Wire connection Input/Output: WAGO 23 Series / Current limitation. x Io typ. WAGO 23 Series Overload behavior Constant current Signalising: WAGO 733 Series Operational indication LED green (Vo), LED red (error) Cross sections Input: 0.08 mm² mm² / Signaling Relay contact DC O.K. (changeover contact) AWG Efficiency / power losses: Efficiency 83 % typ. Output: 0.08 mm² mm² / AWG Power loss P V Fuse protection: Internal fuse 0.5 W (stand-by) / 3.0 W (no load) / 9.4 W (rated load) 2 AT Stripped lengths Signalising: 0.08 mm² mm² / AWG Input: mm / 0.33 in Output: mm / 0.33 in Signalising: mm / 0.22 in External fuse 6 A, 0 A and 6 A circuit breakers, B and C characteristics An external DC fuse is required for DC input voltage. Type of mounting DIN-rail mounting (EN 6075) in 2 positions Dimensions and weight: Dimensions (mm) W x H x L 40 x 63 x 27 Height from upper-edge of DIN 35 rail, dimensions without female plugs Weight approx. 800 g Standards and approvals: EN 60950, EN , UL 60950, UL 508* (* pending)

96 4 94 Primary Switch Mode Power Supply EPSITRON - PRO - Power Interface Modules L N Stand-by DC O.K. DC DC DC - DC - Description Description Primary switch mode power supply with PowerBoost and TopBoost Stand-by input for switching off the output and minimizing power consumption Prepared for class I equipment Natural convection cooling when horizontally mounted Enclosed for use in switchgear cabinets Parallel operation, series connection possible Primary Switch Mode Power Supply, 2 V DC / 0 A Input: Environmental requirements: Nominal input voltage Vi nom /2 x AC Ambient operating temperature -0 C C Input voltage range 85 V V AC; DC Storage temperature -25 C C (use of DC requires external protection) Rel. humidity 30 % % (no condensation) Input voltage derating -5 % / V AC < AC 95 V Derating -3 % / K (>50 C) Frequency 50 Hz Hz Degree of pollution 2 (acc. to EN 5078) Input current Ii 0.97 A at 23 AC and 0 A DC Climatic category 3K3 (acc. to EN 6072) Discharge current ma typ. Safety and protection: Inrush current < 5 Ap Test voltage pri. - sec. 4.2 kv Mains failure hold-up time 35 ms typ. at 23 AC Protection class Prepared for class I equipment Output: Degree of protection IP20 (acc. to EN 60529) Nominal output voltage Vo nom 2 V DC, SELV Overvoltage protection Varistor at primary circuit Output voltage range V... 8 V DC adjustable Short circuit protection yes Output current Io 0 A at 2 V DC No-load proof yes PowerBoost 20 A DC (for 4 s); 5 A DC (for 8 s) Feedback voltage max. 25 V DC TopBoost 60 A DC (for 25 ms); Parallel operation yes 40 A DC at V IN < AC (for 25 ms) Series connection yes Factory preset 2 V DC Connection and type of mounting: Adjustment accuracy % Wire connection Input/Output: WAGO 23 Series / Residual ripple < 70 mvpp WAGO 23 Series Current limitation. x Io typ. Signalising: WAGO 733 Series Overload behavior Constant current Cross sections Input: 0.08 mm² mm² / Operational indication LED green (Vo), LED red (error) AWG Signaling Relay contact DC O.K. (changeover contact) Output: 0.08 mm² mm² / Efficiency / power losses: Efficiency 87.8 % typ. AWG Signalising: 0.08 mm² mm² / Power loss P V Fuse protection: 0.5 W (stand-by) / 5.0 W (no load) / 4.6 W (rated load) Stripped lengths AWG Input: mm / 0.33 in Output: mm / 0.33 in Signalising: mm / 0.22 in Internal fuse 4 AT Type of mounting DIN-rail mounting (EN 6075) External fuse 6 A, 0 A and 6 A circuit breakers, B and C characteristics An external DC fuse is required for DC input voltage. Dimensions and weight: Dimensions (mm) W x H x L in 2 positions 57 x 63 x 27 Height from upper-edge of DIN 35 rail, dimensions without female plugs Weight approx. 00 g Standards and approvals: EN 60950, EN , UL 60950, UL 508* (* pending)

97 Primary Switch Mode Power Supply EPSITRON - PRO - Power 4 95 L N Stand-by DC O.K. DC DC DC - DC - Interface Modules Description Description Primary switch mode power supply with PowerBoost and TopBoost Stand-by input for switching off the output and minimizing power consumption Prepared for class I equipment Natural convection cooling when horizontally mounted Enclosed for use in switchgear cabinets Parallel operation, series connection possible Primary Switch Mode Power Supply, 2 V DC / 5 A Fuse protection: Input: Environmental requirements: Nominal input voltage Vi nom /2 x AC Ambient operating temperature -0 C C Input voltage range 85 V V AC; DC Storage temperature -25 C C (use of DC requires external protection) Rel. humidity 30 % % (no condensation) Input voltage derating -.5 % / V AC < AC Derating -3 % / K (>50 C) Frequency 50 Hz Hz Degree of pollution 2 (acc. to EN 5078) Input current Ii.2 A at 23 AC and 5 A DC Climatic category 3K3 (acc. to EN 6072) Discharge current ma typ. Safety and protection: Inrush current < 8 A (active inrush current limitation) Test voltage pri. - sec. 4.2 kv Mains failure hold-up time 30 ms typ. at 23 AC Protection class Prepared for class I equipment Output: Degree of protection IP20 (acc. to EN 60529) Nominal output voltage Vo nom 2 V DC, SELV Overvoltage protection Varistor at primary circuit Output voltage range V... 8 V DC adjustable Short circuit protection yes Output current Io 5 A at 2 V DC No-load proof yes PowerBoost 30 A DC (for 4 s); 22.5 A DC (for 8 s) Feedback voltage max. 25 V DC TopBoost 55 A DC (for 25 ms) Parallel operation yes Factory preset 2 V DC Series connection yes Adjustment accuracy % Connection and type of mounting: Residual ripple < 70 mvpp Wire connection Input/Output: WAGO 23 Series / Current limitation. x Io typ. WAGO 23 Series Overload behavior Constant current Signalising: WAGO 733 Series Operational indication LED green (Vo), LED red (error) Cross sections Input: 0.08 mm² mm² / Signaling Relay contact DC O.K. (changeover contact) AWG Efficiency / power losses: Efficiency 87 % typ. Output: 0.08 mm² mm² / AWG Power loss P V Fuse protection: Internal fuse 0.8 W (stand-by) / 4.6 W (no load) / 23.4 W (rated load) 6.3 AT Stripped lengths Signalising: 0.08 mm² mm² / AWG Input: mm / 0.33 in Output: mm / 0.33 in Signalising: mm / 0.22 in External fuse 6 A, 0 A and 6 A circuit breakers, B and C characteristics An external DC fuse is required for DC input voltage. Type of mounting DIN-rail mounting (EN 6075) in 2 positions Dimensions and weight: Dimensions (mm) W x H x L 57 x 79 x 27 Height from upper-edge of DIN 35 rail, dimensions without female plugs Weight approx. 300 g Standards and approvals: EN 60950, EN , UL 60950, UL 508* (* pending)

98 4 96 Primary Switch Mode Power Supply EPSITRON - PRO - Power Interface Modules L N Stand-by DC O.K. DC DC DC - DC - Description Description Primary switch mode power supply with PowerBoost and TopBoost Stand-by input for switching off the output and minimizing power consumption Prepared for class I equipment Natural convection cooling when horizontally mounted Enclosed for use in switchgear cabinets Parallel operation, series connection possible Primary Switch Mode Power Supply, DC / 3 A Input: Environmental requirements: Nominal input voltage Vi nom /2 x AC Ambient operating temperature -0 C C Input voltage range 85 V V AC; DC Storage temperature -25 C C (use of DC requires external protection) Rel. humidity 30 % % (no condensation) Input voltage derating -5 % / V AC < AC 95 V Derating -3 % / K (>50 C) Frequency 50 Hz Hz Degree of pollution 2 (acc. to EN 5078) Input current Ii 0.5 A at 23 AC and 3 A DC Climatic category 3K3 (acc. to EN 6072) Discharge current ma typ. Safety and protection: Inrush current < 5 Ap Test voltage pri. - sec. 4.2 kv Mains failure hold-up time 70 ms typ. at 23 AC Protection class Prepared for class I equipment Output: Degree of protection IP20 (acc. to EN 60529) Nominal output voltage Vo nom DC, SELV Overvoltage protection Varistor at primary circuit Output voltage range 22 V V DC adjustable Short circuit protection yes Output current Io 3 A at DC No-load proof yes PowerBoost 6 A DC (for 4 s); 4.5 A DC(for 8 s) Feedback voltage max. 35 V DC TopBoost 4 A DC (for 25 ms) Parallel operation yes Factory preset DC Series connection yes Adjustment accuracy % Connection and type of mounting: Residual ripple < 70 mvpp Wire connection Input/Output: WAGO 23 Series / Current limitation. x Io typ. WAGO 23 Series Overload behavior Constant current Signalising: WAGO 733 Series Operational indication LED green (Vo), LED red (error) Cross sections Input: 0.08 mm² mm² / Signaling Relay contact DC O.K. (changeover contact) AWG Efficiency / power losses: Efficiency 87.8 % typ. Output: 0.08 mm² mm² / AWG Power loss P V Fuse protection: Internal fuse 0.5 W (stand-by) / 3.0 W (no load) / 8.8 W (rated load) 2 AT Stripped lengths Signalising: 0.08 mm² mm² / AWG Input: mm / 0.33 in Output: mm / 0.33 in Signalising: mm / 0.22 in External fuse 6 A, 0 A and 6 A circuit breakers, B and C characteristics An external DC fuse is required for DC input voltage. Type of mounting DIN-rail mounting (EN 6075) in 2 positions Dimensions and weight: Dimensions (mm) W x H x L 40 x 63 x 27 Height from upper-edge of DIN 35 rail, dimensions without female plugs Weight approx. 800 g Standards and approvals: EN 60950, EN , UL 60950, UL 508* (* pending)

99 Primary Switch Mode Power Supply EPSITRON - PRO - Power 4 97 L N Stand-by DC O.K. DC DC DC - DC - Interface Modules Description Description Primary switch mode power supply with PowerBoost and TopBoost Stand-by input for switching off the output and minimizing power consumption Prepared for class I equipment Natural convection cooling when horizontally mounted Enclosed for use in switchgear cabinets Parallel operation, series connection possible Primary Switch Mode Power Supply, DC / 20 A Input: Environmental requirements: Nominal input voltage Vi nom /2 x AC Ambient operating temperature -0 C C Input voltage range 85 V V AC; DC Storage temperature -25 C C (use of DC requires external protection) Rel. humidity 30 % % (no condensation) Input voltage derating -.5 % / V AC < AC Derating -3 % / K ( > 50 C) Frequency 44 Hz Hz Degree of pollution 2 (acc. to EN 5078) Input current Ii 2.3 A at 23 AC and 20 A DC Climatic category 3K3 (acc. to EN 6072) Discharge current ma typ. Safety and protection: Inrush current < 8 A (active inrush current limitation) Test voltage pri. - sec. 4.2 kv Mains failure hold-up time 25 ms typ. at 23 AC Protection class Prepared for class I equipment Output: Degree of protection IP20 (acc. to EN 60529) Nominal output voltage Vo nom DC, SELV Overvoltage protection Varistor at primary circuit Output voltage range 22 V V DC adjustable Short circuit protection yes Output current Io 20 A at DC No-load proof yes PowerBoost 30 A DC (for 4 s); 25 A DC (for 8 s) Feedback voltage max. 35 V DC TopBoost 80 A DC (for 25 ms) Parallel operation yes Factory preset DC Series connection yes Adjustment accuracy % Connection and type of mounting: Residual ripple < 70 mvpp Wire connection Input/Output: WAGO 23 Series / Current limitation. x Io typ. WAGO 83 Series Overload behavior Constant current Signalising: WAGO 733 Series Operational indication LED green (Vo), LED red (error) Cross sections Input: 0.08 mm² mm² / Signaling Relay contact DC O.K. (changeover contact) AWG Efficiency / power losses: Efficiency 9 % typ. Output: 0.5 mm²... 0 mm² / AWG Power loss P V Fuse protection: Internal fuse 0.8 W (stand-by) / 4.8 W (no load) / 50.2 W (rated load) 0 AT Stripped lengths Signalising: 0.08 mm² mm² / AWG Input: mm / 0.33 in Output: mm / 0.55 in Signalising: mm / 0.22 in External fuse 0 A and 6 A circuit breakers, B and C characteristics An external DC fuse is required for DC input voltage. Type of mounting DIN-rail mounting (EN 6075) in 2 positions Dimensions and weight: Dimensions (mm) W x H x L 97 x 87 x 63 Height from upper-edge of DIN 35 rail, dimensions without female plugs Weight approx g Standards and approvals: EN 60950, EN , UL 60950*, UL 508* (* pending)

100 4 98 Primary Switch Mode Power Supply EPSITRON - PRO - Power Interface Modules L N Stand-by DC O.K. DC DC DC - DC - Description Description Primary switch mode power supply with PowerBoost and TopBoost Stand-by input for switching off the output and minimizing power consumption Prepared for class I equipment Natural convection cooling when horizontally mounted Enclosed for use in switchgear cabinets Parallel operation, series connection possible Primary Switch Mode Power Supply, 48 V DC / 5 A Input: Environmental requirements: Nominal input voltage Vi nom /2 x AC Ambient operating temperature -0 C C Input voltage range 85 V V AC; DC Storage temperature -25 C C (use of DC requires external protection) Rel. humidity 30 % % (no condensation) Input voltage derating -.5 % / V AC < AC Derating -3 % / K (>50 C) Frequency 50 Hz Hz Degree of pollution 2 (acc. to EN 5078) Input current Ii.2 A at 23 AC and 5 A DC Climatic category 3K3 (acc. to EN 6072) Discharge current ma typ. Safety and protection: Inrush current < 8 A (active inrush current limitation) Test voltage pri. - sec. 4.2 kv Mains failure hold-up time 20 ms typ. at 23 AC Protection class Prepared for class I equipment Output: Degree of protection IP20 (acc. to EN 60529) Nominal output voltage Vo nom 48 V DC, SELV Overvoltage protection Varistor at primary circuit Output voltage range 33 V V DC adjustable Short circuit protection yes Output current Io 5 A at 48 V DC No-load proof yes PowerBoost 0 A DC (for 4 s); 7.5 A DC (for 8 s) Feedback voltage max. 63 V DC TopBoost 30 A DC (for 25 ms) Parallel operation yes Factory preset 48 V DC Series connection yes Adjustment accuracy % Connection and type of mounting: Residual ripple < 70 mvpp Wire connection Input/Output: WAGO 23 Series / Current limitation. x Io typ. WAGO 23 Series Overload behavior Constant current Signalising: WAGO 733 Series Operational indication LED green (Vo), LED red (error) Cross sections Input: 0.08 mm² mm² / Signaling Relay contact DC O.K. (changeover contact) AWG Efficiency / power losses: Efficiency 9 % typ. Output: 0.08 mm² mm² / AWG Power loss P V Fuse protection: Internal fuse 0.8 W (stand-by) / 7.4 W (no load) / 2.6 W (rated load) 6.3 AT Stripped lengths Signalising: 0.08 mm² mm² / AWG Input: mm / 0.33 in Output: mm / 0.33 in Signalising: mm / 0.22 in External fuse 6 A, 0 A and 6 A circuit breakers, B and C characteristics An external DC fuse is required for DC input voltage. Type of mounting DIN-rail mounting (EN 6075) in 2 positions Dimensions and weight: Dimensions (mm) W x H x L 57 x 79 x 27 Height from upper-edge of DIN 35 rail, dimensions without female plugs Weight approx. 300 g Standards and approvals: EN 60950, EN , UL 60950, UL 508* (* pending)

101 Primary Switch Mode Power Supply EPSITRON - PRO - Power 4 99 L N Stand-by DC O.K. DC DC DC - DC - Interface Modules Description Description Primary switch mode power supply with PowerBoost and TopBoost Stand-by input for switching off the output and minimizing power consumption Prepared for class I equipment Natural convection cooling when horizontally mounted Enclosed for use in switchgear cabinets Parallel operation, series connection possible Primary Switch Mode Power Supply, 48 V DC / 0 A Input: Environmental requirements: Nominal input voltage Vi nom /2 x AC Ambient operating temperature -0 C C Input voltage range 85 V V AC; DC Storage temperature -25 C C (use of DC requires external protection) Rel. humidity 30 % % (no condensation) Input voltage derating -.5 % / V AC < AC Derating -3 % / K (>50 C) Frequency 50 Hz Hz Degree of pollution 2 (acc. to EN 5078) Input current Ii 2.3 A at 23 AC and 0 A DC Climatic category 3K3 (acc. to EN 6072) Discharge current ma typ. Safety and protection: Inrush current < 8 A (active inrush current limitation) Test voltage pri. - sec. 4.2 kv Mains failure hold-up time 20 ms typ. at 23 AC Protection class Prepared for class I equipment Output: Degree of protection IP20 (acc. to EN 60529) Nominal output voltage Vo nom 48 V DC, SELV Overvoltage protection Varistor at primary circuit Output voltage range 33 V V DC adjustable Short circuit protection yes Output current Io 0 A at 48 V DC No-load proof yes PowerBoost 7.5 A DC (for 4 s); 5 A DC (for 8 s) Feedback voltage max. 63 V DC TopBoost 60 A DC (for 25 ms) Parallel operation yes Factory preset 48 V DC Series connection yes Adjustment accuracy % Connection and type of mounting: Residual ripple < 70 mvpp Wire connection Input/Output: WAGO 23 Series / Current limitation. x Io typ. WAGO 83 Series Overload behavior Constant current Signalising: WAGO 733 Series Operational indication LED green (Vo), LED red (error) Cross sections Input: 0.08 mm² mm² / Signaling Relay contact DC O.K. (changeover contact) AWG Efficiency / power losses: Efficiency 9 % typ. Output: 0.5 mm²... 0 mm² / AWG Power loss P V Fuse protection: Internal fuse 0.8 W (stand-by) / 4.8 W (no load) / 43.2 W (rated load) 0 AT Stripped lengths Signalising: 0.08 mm² mm² / AWG Input: mm / 0.33 in Output: mm / 0.55 in Signalising: mm / 0.22 in External fuse 0 A and 6 A circuit breakers, B and C characteristics An external DC fuse is required for DC input voltage. Type of mounting DIN-rail mounting (EN 6075) in 2 positions Dimensions and weight: Dimensions (mm) W x H x L 97 x 87 x 27 Height from upper-edge of DIN 35 rail, dimensions without female plugs Weight approx g Standards and approvals: EN 60950, EN , UL 60950*, UL 508* (* pending)

102 4 00 Primary Switch Mode Power Supply EPSITRON - PRO - Power Interface Modules L L2 L3 DC DC DC - DC - Description Description Primary switch mode power supply with PowerBoost and TopBoost Prepared for class I equipment Natural convection cooling when horizontally mounted Enclosed for use in switchgear cabinets Parallel operation, series connection possible Primary Switch Mode Power Supply, 48 V DC / 0 A Input: Environmental requirements: Nominal input voltage Vi nom 2/3 x AC Ambient operating temperature -0 C C Input voltage range AC; DC Storage temperature -25 C C Frequency 50 Hz Hz Rel. humidity 30 % % (no condensation) Input current Ii. A at 3 x 34 AC Derating -3 % / K (>50 C) Discharge current ma typ. Degree of pollution 2 (acc. to EN 5078) Inrush current < 30 A Climatic category 3K3 (acc. to EN 6072) Mains failure hold-up time 35 ms typ. at 3 x 50 AC Safety and protection: Output: Test voltage pri. - sec. 4.2 kv Nominal output voltage Vo nom 48 V DC, SELV Protection class Prepared for class I equipment Output voltage range 37 V... 5 V DC adjustable Degree of protection IP20 (acc. to EN 60529) Output current Io 0 A at 48 V DC Overvoltage protection Varistor at primary circuit PowerBoost 5 A DC (for 4 s); 3 A DC (for 6 s) Short circuit protection yes TopBoost 55 A DC (for 50 ms) No-load proof yes Factory preset 48 V DC Feedback voltage max. 63 V DC Adjustment accuracy % Parallel operation yes Residual ripple < 70 mvpp Series connection yes Current limitation. x Io typ. Connection and type of mounting: Overload behavior Constant current Wire connection Input/Output: WAGO 23 Series / Operational indication LED green (Vo), LED red (error) WAGO 83 Series Efficiency / power losses: Efficiency 93 % typ. Cross sections Signalising: WAGO 733 Series Input: 0.08 mm² mm² / Power loss P V 8.3 W (no load) / 38 W (rated load) AWG Fuse protection: Internal fuse 3 x 3.2 AT Output: 0.5 mm²... 0 mm² / AWG External fuse 3 x (6 A, 0 A and 6 A) circuit breakers, B and C characteristics An external DC fuse is required for DC input voltage. Stripped lengths Signalising: 0.08 mm² mm² / AWG Input: mm / 0.33 in Output: mm / 0.55 in Signalising: mm / 0.22 in Type of mounting DIN-rail mounting (EN 6075) in 2 positions Dimensions and weight: Dimensions (mm) W x H x L 77 x 79 x 27 Height from upper-edge of DIN 35 rail, dimensions without female plugs Weight approx. 300 g Standards and approvals: EN 60950, EN , UL 60950*, UL 508* (* pending)

103 Primary Switch Mode Power Supply EPSITRON - PRO - Power 4 0 L L2 L3 DC DC DC - DC - Interface Modules Description Description Primary switch mode power supply with PowerBoost and TopBoost Prepared for class I equipment Natural convection cooling when horizontally mounted Enclosed for use in switchgear cabinets Parallel operation, series connection possible Primary Switch Mode Power Supply, 48 V DC / 20 A Input: Environmental requirements: Nominal input voltage Vi nom 2/3 x AC Ambient operating temperature -0 C C Input voltage range AC; DC Storage temperature -25 C C Frequency 50 Hz Hz Rel. humidity 30 % % (no condensation) Input current Ii 2.0 A at 3 x 34 AC Derating -3 % / K (>50 C) Discharge current ma typ. Degree of pollution 2 (acc. to EN 5078) Inrush current < 30 A Climatic category 3K3 (acc. to EN 6072) Mains failure hold-up time 42.9 ms typ. at 3 x 50 AC Safety and protection: Output: Test voltage pri. - sec. 4.2 kv Nominal output voltage Vo nom 48 V DC, SELV Protection class Prepared for class I equipment Output voltage range 37 V... 5 V DC adjustable Degree of protection IP20 (acc. to EN 60529) Output current Io 20 A at 48 V DC Overvoltage protection Varistor at primary circuit PowerBoost 30 A DC (for 4 s); 25 A DC (for 6 s) Short circuit protection yes TopBoost 80 A DC (for 25 ms) No-load proof yes Factory preset 48 V DC Feedback voltage max. 63 V DC Adjustment accuracy % Parallel operation yes Residual ripple < 70 mvpp Series connection yes Current limitation. x Io typ. Connection and type of mounting: Overload behavior Constant current Wire connection Input/Output: WAGO 23 Series / Operational indication LED green (Vo), LED red (error) WAGO 83 Series Efficiency / power losses: Efficiency 94.4 % typ. Cross sections Signalising: WAGO 733 Series Input: 0.08 mm² mm² / Power loss P V 5.2 W (no load) / 59.2 W (rated load) AWG Fuse protection: Internal fuse 3 x 3.2 AT Output: 0.5 mm²... 0 mm² / AWG External fuse 3 x (6 A, 0 A and 6 A) circuit breakers, B and C characteristics An external DC fuse is required for DC input voltage. Stripped lengths Signalising: 0.08 mm² mm² / AWG Input: mm / 0.33 in Output: mm / 0.55 in Signalising: mm / 0.22 in Type of mounting DIN-rail mounting (EN 6075) in 2 positions Dimensions and weight: Dimensions (mm) W x H x L 28 x 205 x 27 Height from upper-edge of DIN 35 rail, dimensions without female plugs Weight approx g Standards and approvals: EN 60950, EN , UL 60950, UL 508* (* pending)

104 4 02 EPSITRON - Lead Gel Battery Modules Interface Modules 5 AT NTC DC Temp Temp DC Description Description Lead Gel Battery Module Lead-acid Absorbed Glass Mat (AGM) battery module for uninterruptible power supply (UPS) Can be connected to UPS Controller Parallel connections to increase the buffer time With built-in NTC K64 temperature sensor DIN 35 mountable rail fastener Input: Fuse protection: Nominal input voltage Vi nom DC Internal fuse 5 AT (Type FK 2) Output: Environmental requirements: Nominal output voltage Vo nom DC Ambient operating temperature -0 C C Output current Io max. 7.5 A Storage temperature -20 C C Final load voltage max. 27 V DC (at 25 C) Service life typ. 5/ 4/ 2 years at 20 C/ 30 C/ Charging current max. 0.3 A 40 C Capacity.2 Ah Safety and protection: Temperature sensor NTC K64 (4.7 kω) Protection class III Degree of protection IP20 (acc. to EN 60529) Connection and type of mounting: Wire connection Input/Output: (WAGO 23 Series) Temperature sensor: (WAGO 23 Series) Cross sections Input/Output: 0.08 mm² mm² / AWG Temperature sensor: 0.08 mm² mm² / AWG Stripped lengths Input/Output: mm / 0.33 in Temperature sensor: mm / 0.33 in Type of mounting DIN-rail mount (EN 6075) Dimensions and weight: Dimensions (mm) W x H x L 55 x 26 x 53 Width, incl. female connector, Height from upper-edge of DIN 35 rail Weight approx g Standards and approvals: Standards/Specifications Battery is tested to VdS

105 EPSITRON - Redundancy Module IN OUT Interface Modules Description Description Redundancy module with 2 inputs for decoupling 2 power supplies For redundant or uninterruptible power supply With potential-free contact for input voltage monitoring Redundancy Module 48V DC, 2 x 20A / x 40A Input: Fuse protection: Nominal input voltage Vi nom 2 x 48 V DC Internal fuse no Input voltage range 36 V V DC Environmental requirements: Input current Ii 2 x 20 A, max. x 40 A Ambient operating temperature -0 C C Output: Storage temperature -25 C C Nominal output voltage Vo nom 48 V DC Rel. humidity 30 % % (no condensation) Output voltage range Ve - V DC Safety and protection: Output current Io 20 A, max. 40 A Test voltage 50 DC (terminals to enclosure) Operational indication LED green (Vo), 2 x LED yellow (Vi) Protection class III Signaling x floating relay contact 3 DC, A Reverse voltage protection yes Degree of protection IP20 (acc. to EN 60529) Efficiency / power losses: Feedback voltage max. 6 DC Efficiency 96 % typ. Parallel operation yes Power loss P V.7 W (no load) / 20 W (rated load) (20 A) / 40 W (rated load) (40 A) Connection and type of mounting: Wire connection Input/Output: (WAGO 83 Series) Relay: (WAGO 23 Series) Cross sections Input/Output: 0.5 mm²... 0 mm² / AWG Relay: 0.08 mm² mm² / AWG Stripped lengths Input/Output: mm / 0.55 in Relay: mm / 0.33 in Type of mounting DIN-rail mounting (EN 6075) in 2 positions Dimensions and weight: Dimensions (mm) W x H x L 40 x 63 x 8 Height from upper-edge of DIN 35 rail T=27mm without pluggable female connectors Weight approx. 000 g Standards and approvals: Standards/Specifications EN 60950, UL 60950*, UL 508*, EN , EN (* pending)

106 4 04 EPSITRON Wall Mounting Adapter Wall mounting adapter, for screw fixing of 787-8xx devices on mounting plate or wall without DIN 35 rail. Wall mounting adapter, for screw fixing of 787-8xx devices on mounting plate or wall without DIN 35 rail. The wall mounting adapter replaces the rail support of the 787-8xx device. The adapter is screwed to the 787-8xx device using one of the provided screws. Description Wall Mounting Adapter Material Galvanized sheet steel Dimensions (mm) W x H x L 35 x 5 x 58.5 Fixing Fixing holes: 4 slots, 5.3 mm x 9 mm Fixing hole spacing: 43 mm x 9.5 mm Included: Wall mounting adapter x screw M4 x 6 x screw M4 x 20 x screw M4 x 30

107 4 05 Interface Modules

108 06 Mobile Printer DYMO RHINO 6000 Print-out preparation: First, insert the label cartridge. To do this, open the cover on the device and insert the cartridge as shown. Ensure the cartridge visibly and audibly locks into place. The two blue catches must latch on to the top edge of the cartridge. Then close the cover. Turn the unit on. A query will appear in the display about setting the material width. Select your current label width and confirm it with "OK." The unit is now ready for use. Note: You can also work with the unit while it is charging. Please use the latest driver. Download: under SERVICE / Download / ProServe Description DYMO RHINO 6000 Mobile Printer Includes: Hard carrying case, AC adapter, battery, RHINO CONNECT software and two marking cartridges with 9 mm and 24 mm adhesive strips WAGO supplementary set for DYMO RHINO 6000 Includes: ProServe CD, ProServe flyer and quick installation guide for adding on to an existing manual printer Accessories Marking strips white, mm width x 5.5 m Adhesive strips white, 9 mm width x 7 m 2-62 Adhesive strips white, 9 mm width x 7 m 2-63 Resolution Tape sizes Tape styles Keyboard style Tape cutter Shock protection Memory Symbols Barcodes Number of font styles 4 Number of font sizes 7 Number of printed lines 5 Print preview yes PC connection USB Display 65 mm x 35 mm Weight approx g Operating time 8 hours Battery charge indicator yes 80 dpi 9 mm, mm, 9 mm, 24 mm (other sizes upon request) Permanent polyester, flexible nylon, vinyl, heat shrink tube ABC yes yes 000 labels ( MB) yes yes (e.g., Code 39, Code 28, EAN 8 3) Heat shrink tube Heat shrink tube white, 9 mm width x,5 m white, 9 mm width x.5 m

109 Flatbed Plotter IP Rugged, aluminum construction Plotting area, A4: 220 mm x 305 mm Easy replacement of marker receptacles Auto calibration Up to 0.5 mm wide markers can be plotted Special solutions for up to 5 mm wide markers are available Universal power supply, 00-24AC Neat plotting right from the very first marker PC interfaces: USB ports Command language: HPGL IP200 firmware can be updated via PC and Internet Description Flatbed plotter IP Plotting area 200 mm x 305 mm Interfaces USB Level. Language Based on HP-GL 7475A Data buffer 6 MB Speed max. 40 mm/s Drive system Two-phase step motor Plotter pen Special plotter pens with HP receptacle Addressable resolution 0.0 mm Repeat accuracy 0.05 mm Repeat accuracy after pen change 0.05 mm with optimun pen Power supply Separate power supply with exchangeable plug adapters Operating voltage AC / 50 Hz Hz Current consumption (internal) 0.7 A max. at 22 AC Dimensions (mm) W x H x L 25 x 440 x 440 Operating temperature 0 C C Rel. humidity 35 % % Safety approvals EN Immunity to interference EN B EN bis 6 EN Included: IP200 Plotter, power supply, USB data cable, operating manual ProServe software

110 08 Crimping Tools Crimping tool 025 Crimping tool for insulated and uninsulated ferrules Crimping range: 0 mm 2, 6 mm 2 and 25 mm 2 Weight: 560 g Crimping tool 3550 Crimping tool for insulated and uninsulated ferrules Crimping range: 35 mm 2 and 50 mm 2 Weight: 560 g Crimping tool 025 Crimping tool 3550 Crimping range: 0 mm 2, 6 mm 2 and 25 mm 2 Crimping range: 35 mm 2 and 50 mm What is "gas-tight?" In a gas-tight connection, the conductor and the ferrule are compressed together, eliminating all spaces. Under normal atmospheric conditions, neither a liquid nor a gaseous medium can penetrate into the crimped connection. Oxidation between crimped single conductors is prevented, ruling out nearly any increase in the crimped connection resistance. In some exceptional cases, minute, isolated spaces may be present. These instances can be considered as closed off due to twisted wires, however. Inadequate crimping can allow the conductor to be pulled out of the connection. Hollow spaces also remain in which oxidation can form and lead to an increase in contact resistance. Elevated resistance is detrimental for signal transmission, as the signal flow is damped (weakened), and for power transmission, as power loss and, hence a temperature increase due to contact (risk of fire) can result. Crimping tools with built-in ratchets are recommended, such as the WAGO Variocrimp tools. These tools only open after the crimping process has been fully completed. Space-saving crimping from all four sides is ideal for spring clamp termination. Cross section data for ferruled conductors indicated for WAGO products is based on this crimping method. Insert ferruled conductor into crimping station. Squeeze handles until ratchet mechanism is released. A perfect gastight crimp - both electrically and mechanically reliable.

111 Uninsulated Ferrules 09 Ferrule, uninsulated, electro-tin plated, electrolytic copper, gastight crimped <D2> < D > < L > Ferrule, uninsulated sleeve for 25 mm² / AWG 4 25 mm strip length L=25 mm D=9.5 mm, D2=7.3 mm Ferrule, uninsulated sleeve for 35 mm² / AWG 2 25 mm strip length L=25 mm D= mm, D2=8.3 mm Ferrule, uninsulated sleeve for 35 mm² / AWG 2 30 mm strip length L=30 mm D= mm, D2=8.3 mm Ferrule, uninsulated sleeve for 50 mm² / AWG 30 mm strip length L=30 mm D=3 mm, D2=0.3 mm Ferrule, uninsulated sleeve for 50 mm² / AWG 35 mm strip length L=35 mm D=3 mm, D2=0.3 mm

112 0 Test and Measurement Tools WAGO Profi LCD 2-pole voltage tester with LCD display 6-00 AC/DC WAGO Profi LED 2-pole voltage tester with LED display 6-00 AC/DC WAGO Profi LCD 2-pole voltage tester with LCD display WAGO Profi LED 2-pole voltage tester with LED display Measuring range: 6 V AC/DC Measuring range: 6 V AC/DC, Degree of protection: IP65 Degree of protection: IP65 Resistance measurement: up to 2000 Ω, removable test probes, 4 mm Ø Resistance measurement: up to 2000 Ω, removable test probes, 4 mm Ø Additional product features for WAGO Profi LCD: Automatic measurement range selection Single-pole phase testing AC >0 Two-pole sequence testing (R and L) Continuity testing FI/RCD testing (30 ma) via buttons One-hand operation for SCHUKO and CEE sockets LED torch lamp function Automatic backlight Auto power-off function CAT IV 00 TÜV/GS tested and approved IEC/EN (DIN VDE ) Additional product features for WAGO Profi LED: Automatic measurement range selection Single-pole phase testing AC >0 Two-pole sequence testing (R and L) Continuity testing FI/RCD testing (30 ma) via buttons One-hand operation for SCHUKO and CEE sockets LED torch lamp function CAT IV 00 TÜV/GS tested and approved IEC/EN (DIN VDE ) WAGO Profi LCD and WAGO Profi LED - Improved socket contact via 4 mm test probes - Removable test probes for small test ports (suitable for all WAGO terminal blocks)

113 WAGO Multi Tester Digital multimeter 60 AC/DC 0 A AC/DC WAGO Amp Tester Digital clamp meter A AC/DC WAGO Multi Tester Digital multimeter with contact-less voltage tester Measuring range: 60 AC/DC 0 A AC/DC Resistance measurement: up to 20 MΩ Includes: carrying case WAGO Amp Tester Digital clamp meter Measuring range: Degree of protection: True RMS measuring method Includes: 0.0 A A AC/DC IP44 carrying case Additional product features for WAGO Multi Tester: Contact-less voltage test AC >0 (optical and acoustical) Resistance measurement up to 20 MΩ Acoustical continuity test Diode test Data hold function Auto power-off function LED torch lamp function CAT IV 60 TÜV/GS tested and approved IEC/EN 600- (DIN VDE 04) Additional product features for WAGO Amp Tester: AC and DC current measurement True RMS measurement Data hold function Maximum jaw opening: 2 mm Ø Compact design for measuring in tight spaces Resolution: 0.0 A at 40 A Resolution: 0. A at 200 A Sampling rate: 3 times per second Auto power-off function CAT III 30 TÜV/GS tested and approved IEC/EN 600- (DIN VDE 04)

114 2 Item Number Index 6 Bit) Page Page Page Page 206 Series 750 Series 756 Series 767 Series Series Series Series Series Series Series Series / / / / / / / / / / / / Series / / / / / / / / / / Series / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / Series / / / / / Series Series Series / / Series Series Series Products highlighted in RED are new items for Spring 20

115 3

116 WAGO Worldwide Companies and Representatives 4 Argentina Bruno Schillig S.A. Arenales 4030, B604CFD Florida, PBA Phone Fax robertor@schillig.com.ar Australia NHP ELECTRICAL ENGINEERING PRODUCTS PTY LTD River Street Richmond, Victoria, 32, P.O. Box 99 Phone Fax export@wago.com Austria WAGO Kontakttechnik Ges.m.b.H. Laxenburger Straße Wien Phone Fax info.at@wago.com Azerbaijan AZ Technics LTD Y.Safarov str.33, AZ025, Baku Phone Fax info@aztechnics.az Belarus UP FEK pr-t Pushkina 29-B Minsk Phone Fax wago@fek.by Belgium WAGO Kontakttechnik Excelsiorlaan 930 Zaventem Phone Fax info-be@wago.com Bosnia and Herzegovina please contact WAGO Bulgaria Brazil WAGO Eletroeletrônicos Ltda Rua Américo Simões 470 São Roque da Chave Itupeva SP Brasil Phone Fax info.br@wago.com Bulgaria WAGO Kontakttechnik GmbH & Co. KG Business Center Serdika 2E Akad. Ivan Geshov Blvd. Building, Floor 4, Offi ce Sofi a Phone Fax info-bg@wago.com Canada please contact WAGO USA Chile Desimat Chile Av Puerto Vespucio 9670 Pudahuel Santiago Phone Fax ventaschile@desimat.cl China WAGO ELECTRONIC (TIANJIN) Co. LTD No.5, Quan Hui Road, Wuqing Development Area Tianjin Phone Fax info-cn@wago.com Columbia T.H.L. Ltda. Cra. 49 B # 9-33 Bogotá Phone Fax ventas-thl@thl-ltda.com Croatia M.B.A. d.o.o. za trgovinu i zastupanje Frana Supila 5 52 Matulji HR Phone Fax mba@ri.htnet.hr GENERA CTR d.o.o. - just for automation technology - Siget 8 b 0020 Zagreb Phone Fax wago@geneza.hr Czech Republic WAGO Elektro spol. sr. o. Rozvodova 6/ Praha 4 - Modřany Phone Fax info.cz@wago.com Denmark WAGO Danmark Filial of WAGO Kontakttechnik GmbH & Co. KG Lejrvej 7 350ærløse Phone Fax salg.dk@wago.com Ecuador ECUAINSETEC CIA LTDA El Zurriago 77 y El Vengador P.O. Box Quito Phone Fax g.castro@ecuainsetec.com.ec Egypt IBN Engineering Instrumentation & Control 7 a El Shaheed Ahmed Hamdi St. King Faisal, Giza Phone Fax sales@ibnengineering.com Estonia Eltarko OÜ Laki Tallinn Phone Fax andres@eltarko.ee Finland WAGO Kontakttechnik GmbH & Co. KG Filial i Finland Vellamonkatu 30 B Helsinki Phone Fax tilaus@wago.fi France WAGO CONTACT S.A. Paris Nord 2 83 Rue des Chardonnerets B.P Tremblay en France ROISSY CDG CEDEX Phone Fax info-fr@wago.com Germany WAGO Kontakttechnik GmbH & Co. KG Postfach 28 80, Minden Hansastraße Minden Phone Fax info@wago.com WAGO Kontakttechnik GmbH & Co. KG Waldstraße Sondershausen Phone Fax info@wago.com Great Britian WAGO Limited Triton Park, Swift Valley Industrial Estate RUGBY Warwickshire, CV2 SG Phone Fax uksales@wago.com Greece PANAGIOTIS SP. DIMOULAS - BIOMAT Kritis Str Athen Phone Fax export@wago.com Hong Kong National Concord Eng., Ltd. A-B, 5/F. Southeast Industrial Building 6-69 Castle Peak Road Tsuen Wan, N.T. Phone Fax sales@nce.com.hk Hungary WAGO Hungá ria KFT Ipari Park, Gyár u Budapest Phone Fax info.hu@wago.com Iceland S. Gudjonsson ehf. Audbrekku Kopavogur Phone Fax export@wago.com India WAGO & CONTROLS (INDIA) LTD. C-27, Sector-58, Phase-III Noida Gautam Budh Nagar (U.P) Phone Fax info@wagoindia.com Indonesia please contact WAGO Singapore Iran Patsa Industry No. 2 Bahar St. South Shiraz Ave P.O. Box.: Tehran Phone Fax export@wago.com Ireland Drives & Controls F4, Riverview Business Park Nangor Road Dublin 2 Phone Fax wago@drivesandcontrols.ie Israel Comtel Israel Electronic Solutions Ltd. Bet Hapaamon 20 Hataas Street P.O. Box Kefar-Saba Phone Fax sales@comtel.co.il Italy WAGO ELETTRONICA SRL Via Parini Casalecchio di Reno (BO) Phone Fax info-ita@wago.com Japan WAGO Co. of JAPAN Ltd. Nittetsu ND-Tower Building 4F Kameido -5-7 Koto-Ku Tokyo Phone Fax info-jp@wago.com Kazakhsta TOO INTANT ul. Muratbaeva, d Almaty Phone Fax info@intant.kz TOO Technik-Trade ul. i. A. Protosanova, Ust-Kamenogorsk Phone Fax info@technik.kz Korea Mahani Electric Co. Ltd Yeoksam-Dong Kangnam-Gu, Seoul, Korea Phone Fax export@wago.com Kosovo please contact WAGO Bulgaria Kuwait Kuwait Controls Company Al Sour Street, Above Lufthansa Airline Safat Kuwait 3062 Phone Fax Latvia INSTABALT LATVIA SIA Vestienas iela 6 Rīga, LV-035 Phone Fax info@instabalt.lv Lebanon Gemayel Trading & Contracting Antonins Project P.O. BOX Antelias, Lebanon Phone Fax gtc.libanon@gmail.com Lithuania INSTABALT LIT UAB Savanorių 87 Vilnius, 2053 Phone Fax info@instabalt.lt Luxembourg please contact WAGO Belgium

117 Macedonia please contact WAGO Bulgaria Malaysia WAGO Representative Offi ce Malaysia No 806, Block A4, Leisure Commerce Square, No 9, Jalan PJS 8/9, 4650 Petaling Jaya, Selangor Darul Ehsan, Malaysia Phone Fax kian.guan.tan@wago.com HPH Materials (M) Sdn Bhd No. 4, Jalan Nilam /6 Suban Hi-Tech Industrial Park Shah Alam Selangor, D.E. Malaysia Phone Fax info@hphmaterials.com Setia Raya Teknik Sdn. Bhd. 40 & 42 Jalan SS5/4 Subang Jaya, P.J. Selangor D.E. Malaysia Phone Fax sales@setiaraya.com.my Mexico WAGO SA de CV Av. Del Marques 38 Bodega 3 P. I. Bernardo Quintana El Marques, Querétaro Phone Fax Toll-Free: info.mx@wago.com Netherlands WAGO Nederland Laan van de Ram BW Apeldoorn Phone Fax info-nl@wago.com New Zealand NHP NZ 7 Lockhart Place Mt Wellington New Zealand Phone Fax export@wago.com Norway WAGO Norge NUF Jerikoveien Oslo Phone Fax info.no@wago.com Pakistan FuziLogiX Automation & Control Suit No. 4, 5th Floor, Shan Arcade New Garden Town, Lahore Pakistan Phone Fax info@fuzilogix.com Peru Desimat Peru Av. Velasco Astete 237 Surco Lima Phone Fax export@wago.com Philippines please contact WAGO Singapore Poland WAGO ELWAG sp. z o. o. ul. Piękna 58 a Wrocław Phone Fax wago.elwag@wago.com Portugal MORGADO & CA. LDA - SEDE Estrada Exterior da Circunvalação 3558/3560 Apartado Rio Tinto Phone Fax export@wago.com Republic of Moldova Electroservice Slavinschi T.T. str. Bolgarskaia 9, offi ce Kishinev Phone Fax es@es.mldnet.com Romania WAGO Kontakttechnik GmbH & Co. KG WAGO Representative Offi ce Bucharest Str. Nicolae G. Caramfi l Nr. 26, Bl. D, Et. 3, Ap. 7, Sect. Bucuresti Romania Phone Fax info-ro@wago.com Romania VDR & Servicii srl Str. Valeriu Branişte, nr. 60, ap., sector 3 Romania Phone /76 Fax offi ce@componente-automatizari.ro SC Civitronic SRL Str. Prof. Gh. Longinescu Nr. 7 Timisoara, Romania Phone Fax sales@civitronic.ro Russia ООО WAGO Kontakt Rus Gostinichny proezd 4B 2706 Moscow Russia Phone Fax info.ru@wago.com WAGO Branch offi ce Ekaterinburg Phone WAGO Branch offi ce Novosibirsk Phone WAGO Branch offi ce St. Petersburg Phone Saudi Arabia Ali Zaid Al Quraishi & Partners Electrical Services of S.A. Al Quraishi Center, King Khalid Street P.O. Box 7386 Dammam Phone Fax export@wago.com Serbia please contact WAGO Bulgaria AVALON Partners D.O.O. Str. Nemanjina 4/XII 000 Belgrade / Serbia Phone Fax Tel/Fax: 65 AVALONP offi ce@avalon.rs Singapore WAGO Electronic Pte Ltd 0 Upper Aljunied Link #04-04 Johnson Controls Building Singapore Phone Fax info-sing@wago.com Slovakia WAGO Elektrik spol. s r. o Odborárska Bratislava Tel export@wago.com Proelektro spol. s r.o. Na barine Bratislava Lamač Tel info@wago.sk Slovenia GENERA d.o.o. Prevale Trzin Phone Fax wago@genera.si IC elektronika d.o.o. Vodovodna cesta Ljubljana Phone Fax info@ic-elect.si South Africa Shorrock Automation (Pty) Ltd Postnet Suite # 29 Private Bag X 8,Elardus Park 0047 Pretoria Phone Fax sales@shorrock.co.za Spain DICOMAT S.L. Avda. de la Industria, 36 Apartado Correos, Alcobendas (Madrid) Phone Fax info@dicomat.com Sweden WAGO Sverige WAGO Kontakttechnik GmbH Tyskland Filial Box 639, 7527 Järfälla Datavägen 9 A, 7543 Järfälla Phone Fax info.se@wago.com Switzerland WAGO CONTACT SA Rte. de l Industrie 9 Case Postale Domdidier Phone 4/ Fax 4/ info.switzerland@wago.com Syria Zahabi Co. 8/5 Shouhadaa St., P.O. Box 8262 Aleppo Phone / 6 Fax export@wago.com Taiwan R.O.C. WAGO Contact, Ltd. 5F., No.68, Jiankang Rd Zhonghe City Taipei County 23585, Taiwan Phone Fax info.taiwan@wago.com Thailand WAGO Representative Offi ce Thailand 4th Floor, KS Building 23/6-8 Rachada Phisek Road Ding Daeng Bangkok 0320 Phone Fax wago@asianet.co.th US Power Distribution Co., Ltd. 4th Floor K.S. Building 23/6-8 Rachada Phisek Road Ding Daeng, Bangkok 0400 Phone Fax wago@asianet.co.th Turkey WAGO Elektronik Sanayi ve Ticaret Ltd. Şti. Barbaros Mahallesi Mimar Sinan Caddesi No Yenisahra - Kadıköy Istanbul Turkey Phone Fax info.tr@wago.com Ukraine NPP Logicon Predslavinskaya street, 39, offi ce Kiev Phone Fax info@logicon.ua OOO Mikropribor ul. Kotelnikova, Kiev Phone Fax sales@micropribor.kiev.ua NPP VD MAIS ul. Dontsia Kiev Phone Fax info@vdmais.kiev.ua ed Arab Emirates (UAE) WAGO Middle East (FZC) Bldg: Z-Offi ce: 9 P.O. Box: Sharjah, UAE Phone Fax USA WAGO Corporation N20 W929 Freistadt Road Germantown, WI Phone Fax Toll-Free: -800 DIN Rail ( ) info.us@wago.com Venezuela PETROBORNAS, C.A. Av. Principal UD 304-Zona Ind. Los Pinos C.C. Los Pinos-Local E 805-Puerto Ordaz-Edo, Bolivar Phone Fax info@petrobornas.net Vietnam please contact WAGO Germany (Minden) Version: 09/200 Current addresses at 5

Channel Digital Input Module 24 V DC High-side switching

Channel Digital Input Module 24 V DC High-side switching 0-0 -Channel Digital Input Module DC High-side switching 0-0 0-0... 9 0 connection 9 9 0 0 0nF 0nF The digital input module provides channels at a width of just mm (0.in). It receives binary control signals

More information

Programmable Fieldbus Controller XTR. Section 2 Section 3.1 Programmable Fieldbus Controllers. Section 3.3 PFC200

Programmable Fieldbus Controller XTR. Section 2 Section 3.1 Programmable Fieldbus Controllers. Section 3.3 PFC200 Programmable Controllers Section 2 Section 3. Programmable Controllers PERSPECTO Control Panels Merging control and visualization 8.9 cm... 38. cm (3.5 5 ) PFC200 Maximum performance in a minimum space

More information

PLC PFC200 Controller PFC200 CS 2ETH RS

PLC PFC200 Controller PFC200 CS 2ETH RS 0-202 PLC PFC200 Controller PFC200 CS 2ETH RS Marking area Serial interface RJ-4 RJ-4 ACT X2 LNK ETH ACT X LNK X3 RS232/4 U U U4 U3 U2 U STOP RESET 0-202 SYS I/O MS NS U RST SD 0 02 A B 24V 0V + + Status

More information

AUTOMATION INTERFACE ELECTRONIC. Supplementary Catalog to Full Line Catalogs, Volumes 3/4 Edition 2013/2 3/4

AUTOMATION INTERFACE ELECTRONIC. Supplementary Catalog to Full Line Catalogs, Volumes 3/4 Edition 2013/2 3/4 AUTOMATION Supplementary Catalog to Full Line Catalogs, Volumes 3/4 Edition 203/2 3/4 The new items in this catalog supplement products found in the following main catalogs 3/4 Volume 4 Volume 3 AUTOMATION

More information

Address. Supply 24 V 0 V Fieldbus connection RJ-45. Fieldbus connection RJ-45. Configuration and programming interface. Pack. System Data.

Address. Supply 24 V 0 V Fieldbus connection RJ-45. Fieldbus connection RJ-45. Configuration and programming interface. Pack. System Data. 20 70-00 PLC PFC00 Controller PFC00 CS 2ETH ECO Address Supply Configuration and programming IP-Adresse ACT X2 LNK ACT X LNK 0V X3 24V 2 3 4 6 7 0: SW/DHCP 2: DHCP RESET STOP RUN SYS RUN I/O MS NS USR

More information

I/O-System 750 and 753 Series

I/O-System 750 and 753 Series -System 750 and 753 Series -System 750 and 753 Series Section 5 Section 6 Highly versatile More than 500 modules available Functional safety Ex i -System 750 XTR Series -System SPEEDWAY For demanding applications

More information

Automation Technology Interface Electronic. Supplementary Catalog to Full Line Catalogs, Volumes 3/4 Edition 2015/2

Automation Technology Interface Electronic. Supplementary Catalog to Full Line Catalogs, Volumes 3/4 Edition 2015/2 Automation Technology Supplementary Catalog to Full Line Catalogs, Volumes 3/4 Edition 2015/2 The new items in this catalog supplement products found in the following main catalogs 3/4 Full Line Catalog,

More information

I/O-SYSTEM/Interface Modules. New Items: Autumn 2009 N 3/4

I/O-SYSTEM/Interface Modules. New Items: Autumn 2009 N 3/4 /Interface Modules New Items: Autumn 2009 N 3/4 N 3/4 The new items in this catalog supplement products found in the following main catalogs Volume 3 Volume 4 Interface Modules WAGO Registered Trademarks

More information

I/O-SYSTEM/Interface Modules. New Items: Spring 2008 N 3/4

I/O-SYSTEM/Interface Modules. New Items: Spring 2008 N 3/4 /Interface Modules New Items: Spring 008 N / Contents Modular IP0 Series 70, 79 ETHERNET TCP/IP -Port Programmable Fieldbus Controller 0 0 ETHERNET TCP/IP & RS- Programmable Fieldbus Controller 0 0 SERCOS

More information

Printview: End module for internal data bus extension - Item No.:

Printview: End module for internal data bus extension - Item No.: Printview: End module for internal data bus extension - Item No: 70-627 End module for internal data bus extension Item No: 70-627 End module for internal data bus extension Marking Business data Supplier

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200F, CPU 1215 FC, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24VDC; 10 DO 24V DC 0.5A; 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200F, CPU 1214 FC, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY 125 KB General information

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes Datasheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY:

More information

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB Display with display Supply

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Datasheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Engineering

More information

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage. Input current. Encoder supply. Power losses Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1217C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT ONBOARD I/O: 10 DI 24V DC; 4 DI RS422/485; 6 DO 24V DC; 0,5A; 4 DO RS422/485; 2 AI 0-10V DC, 2 AQ 0-20MA; POWER SUPPLY: DC

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Product

More information

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 75 KB Display with

More information

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 6 DI 24V DC; 4 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Product

More information

Peripheral modules for distributed automation Wrocław tel ul. Wyścigowa 38 fax w w w. a r a p n e u m a t i k.

Peripheral modules for distributed automation Wrocław tel ul. Wyścigowa 38 fax w w w. a r a p n e u m a t i k. Peripheral modules for distributed automation Digital and Analog Inputs & Outputs, Fieldbus couplers & accessories Autoryzowany dystrybutor Parker: 53-012 Wrocław ul. Wyścigowa 38 tel. 71 364 72 82 fax

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 100 KB General information Firmware

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 50 KB General information

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory Data sheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40...+70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG40-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC 10 DO 24 V DC 2 AI 0-10V DC, POWER

More information

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration NX-series SSI Input Unit CSM DS_E_1_1 Read position information from encoders with Synchronous Serial Interface (SSI). Process SSI encoder input data using the MC Function Modules of the NJ-series Machine

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current Datasheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG31-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER

More information

Modular controllers CECX

Modular controllers CECX Key features At a glance Versatile The controller is functionally designed as a master and motion controller. It is a powerful control unit that can Economical simultaneously execute both comprehensive

More information

I/O-SYSTEM/Interface Modules. New Items: Autumn 2007

I/O-SYSTEM/Interface Modules. New Items: Autumn 2007 /Interface Modules New Items: Autumn 007 Contents Series 70 Modular I/O System, IP 0 ETHERNET TCP/IP -Port Programmable Fieldbus Controller 0 0 ETHERNET TCP/IP & RS- Programmable Fieldbus Controller 0

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet *** SPARE PART*** SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General

More information

General information Engineering with Programming package. Display with display

General information Engineering with Programming package. Display with display Datasheet SIPLUS S7-1200 CPU 1212C AC/DC/RLY -40... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7212-1BE31-0XB0. COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 8 DI 24V DC 6 DO RELAY 2A 2 AI 0-10V DC, POWER

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

WAGO-I/O-SYSTEM. Fieldbus Technology. for Use in Hazardous Areas

WAGO-I/O-SYSTEM. Fieldbus Technology. for Use in Hazardous Areas WAGO-I/O-SYSTEM Fieldbus Technology for Use in Hazardous Areas For Use in Hazardous Areas The WAGO-I/O-SYSTEM 0 is a modular, fi eldbus-independent I/O system for decentralized automation. This system,

More information

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.: Extract from the online catalog MINI MCR-SL-UI-2I-NC Order No.: 2864176 4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration

More information

Remote I/O Product Specification

Remote I/O Product Specification Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 Digital I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications... 2 2.2 Ethernet TCP/IP Specifications...

More information

JUMO mtron T Measuring, Control, and Automation System

JUMO mtron T Measuring, Control, and Automation System Data Sheet 705001 Page 1/10 JUMO mtron T Measuring, Control, and Automation System Central processing unit Brief description The central processing unit is the heart of the system. It contains the process

More information

Remote I/O Product Specification

Remote I/O Product Specification Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 Digital I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications... 2 2.2 Ethernet TCP/IP Specifications...

More information

Controller - PLC-V8C/SC-24DC/BM

Controller - PLC-V8C/SC-24DC/BM Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET

INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET 1 Contents ETHERNET Switches ECO and Standard 3 4 SFP Modules Interface for Fiber-Optic 5 ETHERNET Switches Managed 6

More information

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is

More information

Industrial Switches Industrial Switches

Industrial Switches Industrial Switches Industrial Switches Industrial Switches Copper cables Fiber optic cable Ring redundancy Industrial Switches Contents 23 General Product Information 2 Interfaces and Configurations 2 Application and Installation

More information

WAGO MODULAR IP67 I/O SYSTEM

WAGO MODULAR IP67 I/O SYSTEM WAGO MODULAR IP67 I/O SYSTEM modular design high performance data transfer extended temperature range 300 500 400-25 C +60 C 600 IP67 distributed I/O Reduce system cost and boost performance with WAGO

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output Switched-Mode Power Supplies.,,, VDC Output Nominal output current [ADC] Input, -phase Input, -/-phase EN 0 curus 090 Approvals culus 0 GL ANSI/ISA.. ATEX/IEC Ex DC OK signal/contact RS- serial interface

More information

IP67 IP20. Controllers Open Flexible Compact SPEEDWAY. Programmable. Fieldbus Couplers. Programmable. Fieldbus Controllers

IP67 IP20. Controllers Open Flexible Compact SPEEDWAY. Programmable. Fieldbus Couplers. Programmable. Fieldbus Controllers WAGO Controllers Controllers Open Flexible Compact WAGO s IEC 61131-3 programmable controllers perform a variety of automation tasks, while providing all the benefits of standard PLC technology (e.g.,

More information

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O DATASHEET NI REM-11180 Bus Coupler for Remote I/O Deterministic communication and data transfer to host system EtherCAT cycle time of

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

Controllers CECC Key features

Controllers CECC Key features Key features Application Controller State-of-the-art programming The controllers CECC are modern, compact and versatile controllers that enable programming with CODESYS according to IEC 61131-3. CODESYS

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

Programmable Set for Simple I/O Communication via Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-S-6

Programmable Set for Simple I/O Communication via Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-S-6 CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection

More information

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC) 6ES7212-1BD30-0XB0 Page 1 Product data sheet 6ES7212-1BD30-0XB0 SIMATIC S7-1200, CPU 1212C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 0,5A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC

More information

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555 Industrial Switches Industrial Switch, Base- Industrial Switch, Base- Industrial Switch, Base-, Slots Base-FX Industrial Managed Switch, Base-, Slots Base-FX Industrial Eco Switch, Base- Industrial Eco

More information

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20

More information

TM251MESC controller M251 Ethernet CAN

TM251MESC controller M251 Ethernet CAN Characteristics controller M251 Ethernet CAN Price* : 278.88 GBP Main Range of product Product or component type [Us] rated supply voltage Complementary Number of I/O expansion module Supply voltage limits

More information

. PC cards for all common fieldbus. systems Industrial Ethernet switches. . EtherCAT junctions and media converters in IP 20 and IP 67 ratings

. PC cards for all common fieldbus. systems Industrial Ethernet switches. . EtherCAT junctions and media converters in IP 20 and IP 67 ratings 610. Highlights. PC cards for all common fieldbus. systems. Industrial Ethernet switches. EtherCAT junctions and media converters in IP 20 and IP 67 ratings Infrastructure Components PC Fieldbus Cards,

More information

RSTI-EP Slice I/O. EtherCAT Network Adapter Module EPXETC001. GFK-2967B Septembery 2016

RSTI-EP Slice I/O. EtherCAT Network Adapter Module EPXETC001. GFK-2967B Septembery 2016 Septembery 2016 RSTI-EP Slice I/O EtherCAT Network Adapter Module PWR, BF, MT, L/A IN, L/A OUT, RUN, and ERROR LEDs Ethernet Ports Door for Micro USB Port EtherCAT Network Adapter Power Supply LED The

More information

Remote I/O Product Specification

Remote I/O Product Specification Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 1.1.3 Digital I/O List:... 1 Analog I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications...

More information

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts Data sheet Electronic timer CT-SDS. Star-delta change-over with n/o contacts The CT-SDS. is an electronic timer from the CT-S range with Star-delta change-over and 7 time ranges. All electronic timers

More information

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged

More information

Features and Benefits. Certifications

Features and Benefits. Certifications iopac 8600 Series Rugged modular programmable controllers Features and Benefits Modular CPU/power/backplane design that supports 85M/86M modules Tag-centric design with ready-to-run services Supports C/C++

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet 2CDC 251 056 F0t07 Features Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function ON-delay timer One device includes 10 time ranges (0.05 s - 300 h) 1 c/o contact 2 LEDs for status indication

More information

CM597 Ethernet Communication Module

CM597 Ethernet Communication Module Ordering Data DATA SHEET CM597 Ethernet Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 700 R0001 1SAP 373 700 R0001 CM597-ETH, communication module Ethernet

More information

I/O systems. I/O systems from Phoenix Contact are the perfect solution for control cabinet engineering Axioline F. For the control cabinet (IP20)

I/O systems. I/O systems from Phoenix Contact are the perfect solution for control cabinet engineering Axioline F. For the control cabinet (IP20) 144 PHOENIX CONTACT I/O systems from Phoenix Contact are the perfect solution for control cabinet engineering or field installation. Axioline F Axioline F is Phoenix Contact's I/O system for the control

More information

General information. Supply voltage

General information. Supply voltage Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1

More information

TM241CEC24R controller M IO relay Ethernet CAN master

TM241CEC24R controller M IO relay Ethernet CAN master Characteristics controller M241 24 IO relay Ethernet CAN master Main Range of product Product or component type [Us] rated supply voltage Nov 28, 2017 Modicon M241 Logic controller 100...240 V AC Discrete

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

Electronic timer CT-ERS.21

Electronic timer CT-ERS.21 2CDC 251 057 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function ON delay timer One device includes 10 time ranges (0.05 s 300 h) 2 c/o contacts 2 LEDs for status indication Width

More information

Ver. 01. FnIO S-Series. Integrated Systems for the Speed and Quality

Ver. 01. FnIO S-Series. Integrated Systems for the Speed and Quality Ver. 01 FnIO S-Series Integrated Systems for the Speed and Quality Convenience Economics Stability Considered Design for User. Compact Size : We applied Ultra-small size RTB(Removable Terminal Block) and

More information

Product type designation. General information. Supply voltage

Product type designation. General information. Supply voltage Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1

More information

New Product Highlights. Issue 1/2014

New Product Highlights. Issue 1/2014 New Product Highlights Issue 1/2014 Small and Very Clever 221 Series COMPACT Splicing Connectors for All Wire Types Item No. 221-413 Item No. 221-415 Item No. 221-412 Technical data: 0.14 4 mm 2 (AWG 24

More information

New Product Highlights. Issue 1/2014

New Product Highlights. Issue 1/2014 New Product Highlights Issue 1/2014 WAGO-I/O-SYSTEM 750 XTR Taking it to the extreme The standard for 750 XTR The WAGO-I/O-SYSTEM 750 XTR is easily recognizable by its dark-gray modules. Benefit from the

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is

More information

CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP BL67-PG-EN-V3

CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP BL67-PG-EN-V3 CODESYS V3 programmable acc.to IEC 61131-3 Ethernet and USB programming interface Protection class IP67 Integrated power supply LEDs for display of PLC status, supply voltage, group and bus errors Programmable

More information

CPU 1214C. Overview. Design. The compact CPU 1214C has:

CPU 1214C. Overview. Design. The compact CPU 1214C has: CPU 1214C Overview The compact high-performance CPU With 24 integral input/outputs Expandable by: 1 signal board (SB) or communication board (CB) 8 signal modules (SM) Max. 3 communication modules (CM)

More information

TM241CE40R controller M IO relay Ethernet

TM241CE40R controller M IO relay Ethernet Product data sheet Characteristics TM241CE40R controller M241 40 IO relay Ethernet Complementary Main Discrete I/O number 40 Discrete input logic Discrete input voltage Discrete input voltage type Voltage

More information

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.

More information

QUINT-PS/ 1AC/24DC/20/CO

QUINT-PS/ 1AC/24DC/20/CO Extract from the online catalog QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective

More information

Fieldbus Independent I/O Modules 2 DI DC 24 V 3.0 ms, High-Side Switching (/xxx-xxx) Manual

Fieldbus Independent I/O Modules 2 DI DC 24 V 3.0 ms, High-Side Switching (/xxx-xxx) Manual Fieldbus Independent 2 DI DC 24 V 3.0 ms, High-Side Switching 750-400(/xxx-xxx) Manual Version 1.0.6 ii General Copyright 2006 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik

More information

TM241CE40R controller M IO relay Ethernet

TM241CE40R controller M IO relay Ethernet Characteristics controller M241 40 IO relay Ethernet Main Range of product Product or component type [Us] rated supply voltage Apr 10, 2018 Modicon M241 Logic controller 100...240 V AC Discrete input number

More information

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

IB IL 24/48 DOR 2/W-XC-PAC

IB IL 24/48 DOR 2/W-XC-PAC Inline digital output terminal, version for extreme conditions, 2 relay PDTs Data sheet 8463_en_01 PHOENIX CONTACT 2015-08-12 1 Description The terminal is designed for use within an Inline station. It

More information

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/40 Order No.: 2866242 Uninterruptible power supply 24 V/40 A. In the download area, there is a clearly arranged selection table available with load currents

More information

XC-CPU-201 XC-CPU-201-XV

XC-CPU-201 XC-CPU-201-XV / XC-CPU- XC-CPU--XV Ethernet integrated The / MBit Ethernet interface of the XC offers the perfect link to IT communication. Whether you need rapid access to programs, high-speed data exchange between

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module

More information

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation

More information

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3 Programmable multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP OPC-Server CODESYS V3 programmable acc.to IEC 61131-3 Ethernet and USB programming interface Protection type IP20 Integrated

More information