2 Contents Series 70 Modular I/O System, IP 0 ETHERNET TCP/IP -Port Programmable Fieldbus Controller 0 0 ETHERNET TCP/IP & RS- Programmable Fieldbus Controller 0 0 Programmable Fieldbus Controller for Telecontrol Applications KN IP Programmable Fieldbus Controller BACnet/IP Programmable Fieldbus Controller 0 WAGO ETS Plug-In/WAGO BACnet Configurator WAGOframe PROFIBUS Fieldbus Connector ETHERNET RJ- Connector, IP 0 6 USB Service Cable 7 Series 8 ETHERNET SWITCH -Port 00BASE-T Industrial Switch 8 8-Port 00BASE-T Industrial Switch 9 8-Port 00BASE-T + -Slot 00BASE-F Industrial Switch 0 7-Port 00BASE-T + -Slot 00BASE-F Industrial Managed Switch Accessories, SFP Module Series 76 TO-PASS Telecontrol Technology TO-PASS S, Telecontrol Module TO-PASS M, Telecontrol Module Software 6 Accessories, Antennas, Power Units, Battery and Outdoor Enclosure 7 Series 767 Modular I/O System, IP 67 PROFIBUS DP/V Fieldbus Coupler 8 9 PROFINET Fieldbus Coupler 0 ETHERNET Fieldbus Coupler DeviceNet Fieldbus Coupler CANopen Fieldbus Coupler 6 7 PROFIBUS DP/V Programmable Fieldbus Coupler 8 9 ETHERNET Programmable Fieldbus Coupler 0 CANopen Programmable Fieldbus Coupler Digital Input Module V DC; 8 Inputs (8 x M8) Digital Input Module V DC; 8 Inputs ( x M) 6 7 Digital Output Module V DC/0. A; 8 Outputs (8 x M8) 8 9 Digital Output Module V DC/0. A; 8 Outputs ( x M) 60 6 Digital Output Module V DC/.0 A; 8 Outputs (8 x M8) 6 6 Digital Output Module V DC/.0 A; 8 Outputs ( x M) 6 6 Analog Input Module Voltage/Current; Inputs Analog Input Module RTD; Inputs Analog Output Module Voltage/Current; Outputs 70 7 Power Divider V DC 7 7 Accessories, Cable, Connectors, Marking 7 79 Contents Interface Modules Series 88 Relay Socket and Industrial Relays Relay Socket for Industrial Relays 80 Industrial Relays 8 Accesories, Operation Status Indicator, Holding Bracket 8 Series 89 Interface Modules Interface Module with High-Density D-Sub Header for 9" Racks 8

3 70-87 ETHERNET TCP/IP Port Programmable Fieldbus Controller 0/00 Mbits/s; digital and analog signals Fieldbus connection RJ- Fieldbus connection RJ- ETHERNET LINK MS NS TxD/RxD I/O USR A B 0 0 V 0V + + C D Status voltage supply -System -Power jumer contacts Data contacts V 0 V via power jumper contacts V Address ON W V Configuration and programming interface Power jumper contacts This fieldbus controller connects the WAGO- to the ETHERNET fieldbus. The fieldbus controller automatically configures, creating a local process image that may include analog, digital or specialty modules. Analog and specialty module data is sent via words and/or bytes; digital data is sent bit by bit. This fieldbus controller permits data transmission rates of 0/00 Mbits/s and is programmable in accordance with IEC 6-. The controller provides KB program memory, 6 KB data memory and KB retain memory. It is capable of multitasking, has a battery-backed, real-time clock and is based on a -bit CPU. The controller offers many different application protocols which can be used for data acquisition or control (MODBUS, ETHERNET/IP) or for system management and diagnostics (HTTP, BootP, DHCP, DNS, SNTP, FTP, SNMP and SMTP). HTML pages can be placed on an internal server for use in Web-based applications. The second Ethernet interface allows daisy-chaining up to a maximum segment length of 00 m. Due to signal propagation time, the maximum number of controllers that can be wired in series is 0. In addition, the controller provides the option of configuring the IP address via built-in DIP switch. Description ETHERNET TCP/IP -Port Controller Accessories WAGO-I/O-PRO CAA 79- Miniature WSB quick marking system Plain 8-0 with marking see Full Line Catalog W Volume System Data No. of controllers connected to Master limited by ETHERNET specification Transmission medium Twisted Pair S-UTP 00 Ω Cat Max. length of fieldbus segment 00 m hub station and 70-87; max. length of network limited by ETHERNET specification Baud rate 0/00 Mbits/s Buscoupler connection x RJ- Protocols MODBUS/TCP (UDP), ETHERNET/IP, HTTP, BootP, DHCP, DNS, SNTP, FTP, SNMP, SMTP Programming WAGO-I/O-PRO CAA IEC 6- IL, LD, FBD, ST, FC Approvals Conformity marking

4 FI ELDBUS I NTERFA CE ELECTRON ICS V /0 V V 0 V V 0 V V 0 V 0 nf 0 nf DC DC ELECTRONICS FIELDBUS I NTERFACE I/O modules Number of I/O modules 6 With bus extension 0 Fieldbus Max. input process image Kbytes Max. output process image Kbytes Input variables (max.) bytes Output variables (max.) bytes Configuration via PC Program memory Kbytes Data memory 6 Kbytes Non-volatile memory (retain) Kbytes (6 Kbytes retain, 8 Kbytes flag) Voltage supply DC V (- % %) Max. input current ( V) 00 ma Efficiency of the power supply 87 % Internal current consumption ( V) 00 ma Total current for I/O modules ( V) 700 ma Isolation 00 V system/supply Voltage via power jumper contacts DC V (- % %) Current via power jumper contacts (max.) DC 0 A General Specifications Operating temperature 0 C... + C Wire connection CAGE CLAMP Cross sections 0.08 mm².... mm² / AWG 8... Stripped lengths mm / 0. in Dimensions (mm) W x H x D x6x00 Height from upper-edge of DIN rail Weight 8 g Storage temperature - C C Relative air humidity (no condensation) 9 % Vibration resistance acc. to IEC Shock resistance acc. to IEC Degree of protection IP0 EMC -Immy to interference acc. to EN (999) EMC -Emission of interference acc. to EN 008- (99)

5 70-87 ETHERNET TCP/IP & RS- Programmable Fieldbus Controller 0/00 Mbits/s; digital and analog signals Fieldbus connection RJ- ETHERNET LINK MS NS TxD/RxD I/O USR A B 0 0 V 0V + + C D Status voltage supply -System -Power jumer contacts Data contacts V 0 V via power jumper contacts V Fieldbus connection RS- W V Configuration and programming interface Power jumper contacts This fieldbus controller connects the WAGO- to ETHERNET. The fieldbus controller automatically configures, creating a local process image that may include analog, digital or specialty modules. Analog and specialty module data is sent via words and/or bytes; digital data is sent bit by bit. This fieldbus controller permits data transmission rates of 0/00 Mbits/s and is programmable in accordance with IEC 6-. The controller provides KB program memory, 6 KB data memory and KB retain memory. It is capable of multitasking, has a battery-backed, real-time clock and is based on a -bit CPU. The controller offers many different application protocols which can be used for data acquisition or control (MODBUS, ETHERNET/IP) or for system management and diagnostics (HTTP, BootP, DHCP, DNS, SNTP, FTP, SNMP and SMTP). HTML pages can be placed on an internal server for use in Web-based applications. The integrated RS- interface communicates with external devices. The controller can also be addressed as Modbus RTU slave via RS- interface. Description ETHERNET TCP/IP RS- Controller Accessories WAGO-I/O-PRO CAA 79- Miniature WSB quick marking system Plain 8-0 with marking see Full Line Catalog W Volume System Data System data ETHERNET: No. of controllers connected to Master limited by ETHERNET specification Transmission medium Twisted Pair S-UTP 00 Ω Cat Max. length of fieldbus segment 00 m hub station and 70-87; max. length of network limited by ETHERNET specification Baud rate 0/00 Mbits/s Buscoupler connection RJ- Protocols MODBUS/TCP (UDP), ETHERNET/IP, HTTP, BootP, DHCP, DNS, SNTP, FTP, SNMP, SMTP System data Serial: Transmission medium shielded Cu cable () x 0. mm² Max. length of fieldbus segment 00 m (depends on the baud rate / on the cable) Baud rate (00) 0 baud... (00) 900 baud Buscoupler connection x D-Sub 9; socket Programming WAGO-I/O-PRO CAA IEC 6- IL, LD, FBD, ST, FC Approvals Conformity marking

6 FI ELDBUS I NTERFA CE ELECTRON ICS V /0 V V 0 V V 0 V V 0 V 0 nf 0 nf DC DC ELECTRONICS FIELDBUS I NTERFACE I/O modules Number of I/O modules 6 With bus extension 0 Fieldbus Max. input process image Kbytes Max. output process image Kbytes Input variables (max.) bytes Output variables (max.) bytes Configuration via PC Program memory Kbytes Data memory 6 Kbytes Non-volatile memory (retain) Kbytes (6 Kbytes retain, 8 Kbytes flag) Voltage supply DC V (- % %) Max. input current ( V) 00 ma Efficiency of the power supply 87 % Internal current consumption ( V) 00 ma Total current for I/O modules ( V) 700 ma Isolation 00 V system/supply Voltage via power jumper contacts DC V (- % %) Current via power jumper contacts (max.) DC 0 A General Specifications Operating temperature 0 C... + C Wire connection CAGE CLAMP Cross sections 0.08 mm².... mm² / AWG 8... Stripped lengths mm / 0. in Dimensions (mm) W x H x D x6x00 Height from upper-edge of DIN rail Weight approx. 8 g Storage temperature - C C Relative air humidity (no condensation) 9 % Vibration resistance acc. to IEC Shock resistance acc. to IEC Degree of protection IP0 EMC -Immy to interference acc. to EN (999) EMC -Emission of interference acc. to EN 008- (99)

7 ,70-87/ Programmable fieldbus controller for telecontrol applications 0/00 Mbits/s; digital and analog signals Fieldbus connection RJ- ETHERNET LINK MS NS TxD/RxD I/O USR A B 0 0 V 0V + + C D Status voltage supply -System -Power jumer contacts Data contacts V 0 V via power jumper contacts V W V D-Sub (only for 70-87) Configuration and programming interface Power jumper contacts The programmable fieldbus controller of the WAGO- meets the requirements for use in telecontrol applications. The controller offers many different application protocols which can be used for data acquisition or control (MODBUS TCP/-RTU, IEC /-0, 96R, RK, ETHERNET/IP) or for system management and diagnostics (HTTP, BootP, DHCP, DNS, SNTP, FTP, SNMP and SMTP). HTML pages can be placed on an internal server for use in WEB-based applications. Programs can be called directly via ML and ASP. Furthermore, the product incorporates library functions for , SOAP, ASP, IP configuration, ETHERNET sockets and file system. The controller, based on a -bit CPU, is capable of multitasking and has a battery-backed, real-time clock. Programming of the application is done with WAGO-I/O-PRO CAA in accordance with IEC 6-. The programmer can access all fieldbus and I/O data. The programmer can access the IEC and 0 telecontrol protocol via function blocks using the CoDeSys program. As an alternative, users who do not want to write a PLC program can simply parameterize the IEC and -0 telecontrol protocol within the CoDeSys environment. Description Telecontrol Controller RJ- + D-Sub Telecontrol Controller RJ / Accessories WAGO-I/O-PRO CAA 79- Miniature WSB Quick marking system Plain 8-0 with marking see Full Line Catalog W Volume System Data System data ETHERNET: No. of controllers connected to Master limited by ETHERNET specification Transmission medium Twisted Pair S-UTP 00 Ω Cat Max. length of fieldbus segment 00 m hub station and 70-87; max. length of network limited by ETHERNET specification Baud rate 0/00 Mbits/s Buscoupler connection RJ- Protocols MODBUS/TCP (UDP), ETHERNET/IP, HTTP, BootP, DHCP, DNS, SNTP, FTP, SNMP, SMTP System data Serial: (only for 70-87) No. of controllers connected to Master limited Transmission medium shielded Cu cable () x 0. mm² Max. length of fieldbus segment 00 m (depends on the baud rate / on the cable) Baud rate 9600 baud baud Buscoupler connection x D-Sub 9; socket Approvals Marine applications see Full Line Catalog W Volume Conformity marking Programming IEC 6- Libraries WAGO-I/O-PRO CAA IL, LD, FBD, ST, FC IEC /-0, 96R/RK

8 7 FI ELDBUS I NTERFA CE ELECTRON ICS V /0 V V 0 V V 0 V V 0 V 0 nf 0 nf DC DC ELECTRONICS FIELDBUS I NTERFACE I/O modules Number of I/O modules 6 with bus extension 0 Fieldbus Max. input process image Kbytes Max. output process image Kbytes Input variables (max.) bytes Output variables (max.) bytes Configuration via PC Program memory Kbytes Data memory 6 Kbytes Non-volatile memory (retain) Kbytes (6 Kbytes retain, 8 Kbytes flag) File system MB 70-87/ MB Voltage supply DC V (- % %) Max. input current ( V) 00 ma Efficiency of the power supply 87 % Internal current consumption ( V) 00 ma Total current for I/O modules ( V) 700 ma Isolation 00 V system/supply Voltage via power jumper contacts DC V (- % %) Current via power jumper contacts (max.) DC 0 A IEC and -0 library Document of conformity see Number of control stations Number of information objects General Specifications Operating temperature 0 C... + C Wire connection CAGE CLAMP Cross sections 0.08 mm².... mm² / AWG 8... Stripped lengths mm / 0. in Dimensions (mm) W x H x L x 6 x 00 Height from upper-edge of DIN rail Weight approx. 8 g Storage temperature - C C Relative air humidity (no condensation) 9 % Vibration resistance acc. to IEC Shock resistance acc. to IEC Degree of protection IP0 EMC -Immy to interference acc. to EN (999) EMC -Emission of interference acc. to EN 008- (99)

9 KN IP Programmable Fieldbus Controller 0/00 Mbits/s; digital and analog signals Fieldbus connection RJ- Fieldbus connection RJ- Programming button for router modus and device mode PRG IP PRG RT KN IP LNK ACT LNK ACT 0 0 MS/PRG IP V 0V NS/PRG RT I/O USR W A B + + C D Status voltage -System -Power jumper contacts Data contacts V 0 V via power jumper contacts V 0V Configuration and programming interface (flap open) Power jumper contacts Mode switch The controller can include up to two logical KN devices at the same time.. In conjunction with the WAGO-, the KN IP Controller can be used as a programmable application controller within the KN IP network. The controller supports 70/7 Series digital, analog and specialty modules. The controller facilitates data transmission rates of 0/00 Mbits/s. It is programmable in accordance with IEC 6-. KN objects of any type (EIS/DPT) can be created using the programming tool. Libraries including ready-made function blocks are readily available on the WAGO Web site for programming. The controller supports a maximum of communication objects, group addresses and associations. Supported DPTs: All (acc. to KN standard 0_07_0 Datapoint Types V.0).. Combined with the KN/EIB/TP module, the KN IP Controller can be operated as router on an IP backbone (Ethernet). No IEC application is required for the router functionality. Both devices are commissioned and configured in the ETS using the WAGO product database. The software includes a plug-in that automatically installs and opens for configuration. The KN IP Controller features an integrated -port 0/00 Mbits/s switch and allows easy line structure creation without requiring additional network components. The maximum number of controllers that can be wired in series is 0. An internal server is available for Web-based applications. The controller has KB program memory, 6 KB data memory and KB retentive memory. It is capable of multitasking, has a battery-backed, real-time clock and is based on a -bit CPU. The controller offers many different application protocols for control tasks (Modbus, KNnet/IP), as well as for system management and diagnostics (HTTP, BootP, DHCP, DNS, AutoIP, SNTP, FTP, SNMP and SMTP). The number of KN/EIB/TP modules (70-66) that are supported by the KN IP Controller does not depend on the application. Description KN IP Controller Accessories Miniature WSB Quick marking system plain 8-0 with marking see Full Line Catalog W Volume WAGO ETS plug-in (included in WAGO ETS product database) Download: Service Downloads Gebäudeautomation ETS Produktdatenbank Approvals r UL 08 EN pending r ANSI/ISA..0 pending Conformity marking KN certified KN (pending) System Data No. of controllers limited by network topology Transmission medium S-UTP 00 Ω Cat Max. length of fieldbus segment 00 m limited by IEEE 80. Max. length of network 000 m; max. 0 controllers in series Baud rate 0/00 Mbits/s Buscoupler connection x RJ- (linked via -port switch) Protocols KNnet/IP, MODBUS/TCP (UDP), HTTP, BootP, DHCP, DNS, AutoIP, SNTP, FTP, SNMP V, SMTP Programming WAGO-I/O-PRO CAA IEC 6- IL, LD, FBD (CFC), ST, FC KN-specific KN/TP bus specification.0 Commissioning (KN side) with ETS plug-in, programming buttons Device mode: Number of communication objects Number of group addresses Number of associations Supported DPTs All ( *acc. to KN Specification 0_07_0 Data Point Types V.0) Max. number of logical KN devices, simultaneous ;. device,. router (with. KN/EIB/TP module)

10 9 FI ELDBUS I NTERFA CE ELECTRON ICS V /0 V V 0 V V 0 V V 0 V 0 nf 0 nf DC DC ELECTRONICS FIELDBUS I NTERFACE I/O modules Number of I/O modules 6 with bus extension 0 Configuration via PC Program memory Kbytes Data memory 6 Kbytes Non-volatile memory (retain) Kbytes (6 Kbytes retain, 8 Kbytes flag) Voltage supply DC V (-% %) Max. input current ( V) 00 ma Efficiency of the power supply 87 % Internal current consumption ( V) 00 ma Total current for I/O modules (V) 700 ma Isolation 00 V system/supply Voltage via power jumper contacts DC V (-% %) Current via power jumper contacts (max.) DC 0 A Fieldbus (Modbus/TCP): Max. input process image Kbytes Max. output process image Kbytes Input variables (max.) bytes Output variables (max.) bytes General Specifications Operating temperature 0 C... + C Wire connection CAGE CLAMP Cross sections 0.08 mm².... mm² / AWG 8... Stripped lengths mm / 0. in Dimensions (mm) W x H x L x 6 x 00 Height from upper-edge of DIN rail Weight approx. 90 g Storage temperature - C C Relative air humidity (no condensation) 9 % Vibration resistance acc. to IEC Shock resistance acc. to IEC Degree of protection IP 0 EMC -Immy to interference acc. to EN (00) EMC -Emission of interference acc. to EN (00) + A:00

11 BACnet/IP Programmable Fieldbus Controller 0/00 Mbits/s; digital and analog signals Fieldbus connection RJ- BACnet/IP LINK ACT BT MS NS I/O USR A B 0 0 C D V 0V + + Status voltage supply -System -Power jumer contacts Data contacts V 0 V via power jumper contacts V Fieldbus connection RS- 0 V Service interface as configuration and programming interface (with cover open) Power jumper contacts Mode switch The BACnet/IP Controller connects the WAGO- with the BACnet protocol. The controller corresponds to BACnet B-BC device profile according to DIN EN ISO 68-. The controller provides the three following functionalities:.native server: For each channel, appropriate BACnet objects are generated automatically for the digital, analog input and output modules that are connected to the controller..application server: Other supported BACnet objects can be created via IEC 6- programming environment..application client: Using the client functionality, objects and their properties can be accessed by other BACnet devices. Description BACnet/IP Controller Accessories Miniature WSB Quick marking system plain 8-0 with marking see Full Line Catalog W Volume PC software WAGO BACnet Configurator Access to BACnet/IP networks is provided by the controller's RJ- interface. The RS- interface can be used as standard RS- or as BACnet-PTP connection to other PTP-capable BACnet devices. For the Controller, application programming is completed with WAGO-I/O-PRO CAA in accordance with IEC 6-. The controller, based on a -bit CPU, is capable of multitasking and has a battery-backed, real-time clock. HTML pages can be placed on an internal server for use in Web-based applications. Start-up and configuration of the BACnet networks is performed using the Windows-compliant WAGO BACnet Configurator. System Data System data ETHERNET: No. of controllers limited by network topology Transmission medium S-UTP 00 Ω Cat Max. length of fieldbus segment 00 m limited by IEEE 80. Max. length of network acc. to IEEE 80. standard Baud rate 0/00 Mbits/s Buscoupler connection x RJ-, x RS- Protocols BACnet/IP, BACnet PTP, MODBUS/TCP (UDP), HTTP, BootP, DHCP, DNS, SNTP, FTP, SNMP V, SMTP System data Serial (BACnet PTP): Baud rate 9600 baud baud Max. length of fieldbus segment m depending on the baud rate / on the cable (at 900 baud) Buscoupler connection x D-Sub 9; socket Programming WAGO-I/O-PRO CAA IEC 6- IL, LD, FBD (CFC), ST, FC BACnet device profile B-BC (BACnet Building Controller) Approvals r UL 08 Conformity marking BACnet conformity test BACnet conformity (pending)

12 FI ELDBUS I NTERFA CE ELECTRON ICS V /0 V V 0 V V 0 V V 0 V 0 nf 0 nf DC DC ELECTRONICS FIELDBUS I NTERFACE I/O modules Number of I/O modules 6 with bus extension 0 Configuration via PC Program memory Kbytes Data memory 6 Kbytes Non-volatile memory (retain) Kbytes (6 Kbytes retain, 8 Kbytes flag) Voltage supply DC V (-% %) Max. input current ( V) 00 ma Efficiency of the power supply 87 % Internal current consumption ( V) 00 ma Total current for I/O modules (V) 700 ma Isolation 00 V system/supply Voltage via power jumper contacts DC V (-% %) Current via power jumper contacts (max.) DC 0 A BACnet implementation acc. to DIN EN ISO 68- =ANSI/ASHRAE -00 Fieldbus (Modbus/TCP): Max. input process image Kbytes Max. output process image Kbytes Input variables (max.) bytes Output variables (max.) bytes General Specifications Operating temperature 0 C... + C Wire connection CAGE CLAMP Cross sections 0.08 mm².... mm² / AWG 8... Stripped lengths mm / 0. in Dimensions (mm) W x H x L x 6 x 00 Height from upper-edge of DIN rail Weight approx. 88 g Storage temperature - C C Relative air humidity (no condensation) 9 % Vibration resistance acc. to IEC Shock resistance acc. to IEC Degree of protection IP 0 EMC -Immy to interference acc. to EN (00) EMC -Emission of interference acc. to EN (00) + A:00

13 WAGO ETS Plug-In/WAGO BACnet Configurator Description WAGO ETS Plug-In Description WAGO BACnet Configurator The WAGO ETS Plug-In is an ETS product database extension that allows the use of WAGO products, such as: the 7-66 KN/EIB/TP Module, the KN IP Controller as well as the KNnet/IP Router (consisting of KN module and KN IP Controller). This ETS extension represents the type of control software that gives the ETS access to new options for WAGO devices and enables their configuration. The software s enhanced structure offers intuitive navigation providing both experienced ETS users and newcomers with exceptional usability. A key feature of the KN/EIB/TP Module or controller software is that the PLC variables : are mapped in the communication objects of the ETS. When a group address is assigned for the first time, the communication object is made visible within the ETS. When the objects are disconnected again, they are no longer visible within the ETS. The WAGO BACnet Configurator is an independent commissioning, configuration and management software. Among the configurator s capabilities are the logical structuring of the project and network, addressing of the controller and configuration of the client and the server in every BACnet/IP Controller. The representation of the devices, objects and configuration data is done in a logical, structured network and an IP view, which is divided into client/server function and its location in the building. The configurator displays all configuration data. The user may change the data, load it onto either one, or several, controllers and save it in an override file. The configurator provides a browser to view the BACnet object properties and modify the current parameters (communicate value changes, write property values, utilize BACnet services, etc.). Additionally, a LOG window is also available for client services. System requirements: Operating System: Windows 98, Windows 000, Windows P (P recommended) Other: The Plug-In requires the ETS in version.0d System requirements: Operating System: Windows 000/P The ETS Plug-In can be downloaded for free. see: The WAGO BACnet Configurator can be downloaded for free. see:

14 WAGOframe FDT frame application for parameterization, commissioning and diagnostics of devices with DTM device driver WAGOframe: Parameterizing a JUMPLE transducer WAGOframe: Wizard function Description WAGOframe WAGOframe is an FDT/DTM-based software used for parameterization, commissioning and diagnostics of field devices. DTM device drivers for the devices employed are required to use the WAGOframe FDT frame application. The WAGOframe FDT frame application provides a wizard, which simplifies the operation of components, such as WAGO JUMPFLE DTMs. For example, this wizard guides the user through the different operating modes of DTM device drivers. Depending on the PC communication interface used, an appropriate communication cable including DTM is required. System requirements: PC Pentium GHz or higher Operating system Microsoft Windows 000 Microsoft Windows P Professional Microsoft Windows Vista Memory Min. Mbytes (Windows P) Min. 0 Mbytes (Windows Vista) Hard disk storage Min. 0 Mbytes CD ROM required Graphics card GA or higher; Mouse required Other Free interface in PC for communication with the device (e.g., USB, Serial, ETHERNET,...) Included: Additional requirements: CD ROM with software and documentation Cable between PC communication interface and device. DTM software for the communication interface used in the PC. DTM software of the device. Windows is a registered trademark of Microsoft Corporation

15 70-97 PROFIBUS Fieldbus Connector 6. mm.9 mm 7.8 mm Thread ø mm B A B A S 90 Ω 0 Ω 90 Ω Male connector mm.6 mm. mm mm mm. mm mm 6 mm 7 mm The fieldbus connector links a PROFIBUS device to a PROFIBUS line. The fieldbus connector has the following features: Compact design. It is particularly well-suited for the connection to an S7 PLC. No losable parts. horizontal cable entries. One input and one output. Fast and maintenance-free CAGE CLAMP connection, can be held in the open position with the help of an actuation slide mechanism. Externally operable switch to activate and/or deactivate the network terminating resistor. For the first and last station on the bus, the switch must be set to ON (terminating resistor activated, outgoing bus line disconnected). Switch setting to OFF for the intermediate stations on the bus (terminating resistor deactivated). Description Bus Connector with D-Sub Male Connector; 9 Poles Accessories Screwdriver with partially insulated shaft Type, blade. x 0. mm / x 0.06 in Test pin, mm / 0.09 in Test wire for soldering Markers Double cable input Ø 8. mm Data transmission rate corresponding to PROFIBUS specification up to Mbits/s Voltage supply DC.7 V.... V Current consumption max. (internal) ma Fixing screw UNC- A -0 Max. tightening torque 0. Nm Housing material PC-V0 Housing color light gray Degree of protection IP 0 Ambient operating temperature 0 C C Storage temperature - C C Relative air humidity (no condensation) 9 % Wire connection CAGE CLAMP terminal strip with locking slide (WAGO Series 8) mm² / AWG sep. connection 0.7 mm / AWG 8 possible Stripped length see graphic

16 70-97 PROFIBUS Fieldbus Connector 6. mm. mm 7.8 mm Thread ø mm B A B A S Female connector 90 Ω 0 Ω 90 Ω Male connector 9 9 mm. mm. mm mm mm. mm mm 6 mm 7 mm The fieldbus connector links a PROFIBUS device to a PROFIBUS line. The fieldbus connector has the following features: Compact design. It is particularly well-suited for the connection to an S7 PLC. No losable parts. PG interface horizontal cable entries. One input and one output. Fast and maintenance-free CAGE CLAMP connection, can be held in the open position with the help of an actuation slide mechanism. Externally operable switch to activate and/or deactivate the network terminating resistor. Description Bus Connector with D-Sub Male and Female Connectors; 9 Poles Accessories Screwdriver with partially insulated shaft Type, blade. x 0. mm / x 0.06 in Test pin, mm / 0.09 in Test wire for soldering Markers For the first and last station on the bus, the switch must be set to ON (terminating resistor activated, outgoing bus line disconnected). Switch setting to OFF for the intermediate stations on the bus (terminating resistor deactivated). Double cable input Ø 8. mm Data transmission rate corresponding to PROFIBUS specification up to Mbits/s Voltage supply DC.7 V.... V Current consumption max. (internal) ma Fixing screw UNC- A -0 Max. tightening torque 0. Nm Housing material PC-V0 Housing color light gray Degree of protection IP 0 Ambient operating temperature 0 C C Storage temperature - C C Relative air humidity (no condensation) 9 % Wire connection CAGE CLAMP terminal strip with locking slide (WAGO Series 8) mm² / AWG sep. connection 0.7 mm / AWG 8 possible Stripped length see graphic

17 Ethernet RJ- Connector, IP 0 Ethernet 0/00 Mbit/s; for field assembly < mm > R9 <_ mm _> <_ mm _> < min. mm / max. 9 mm > < 6,6 > <,7 mm > < 6,0 mm > Versatile RJ- connector for industrial, office and building wiring. The compact RJ- uses IDC technology for easy field assembly connection is made without tools. The connector is compliant with all required standards. Large conductor cross sections can also be connected and the connector satisfies Category e. Description Ethernet RJ- Connector, IP General specifications: No. of poles 8 Contact material Bronze (CuSn6) Contact plating >. μm gold over. μm nickel Insulation material Connector, polycarbonate (UL-9-V0) Housing material Plastic, gray, (UL9-V0) Mating cycles min. > 000 Wire connection IDC acc. to 60- IDC surface treatment Tin-plated, approx. μm Cross section solid: 0. mm mm / AWG 6/... /; stranded: 0. mm mm / AWG 6/7... /7 Admissible insulation Ø.60 mm Cable jacket Ø. mm mm Wire strain relief With plastic ribs Cable strain relief > 0 N Shield contacting Large surface >80 (on cable shield) Shield material Brass (CuZn), hot-dip tinned μm Temperature range -0 C C Storage temperature -0 C C Electrical data Contact resistance (wire IDC) < mω; (strand IDC) < mω Connector shield < 0 mω Insulation resistance (00 V) > 00 MΩ Dielectric strength (contact-contact) > 000 V, min.; (shield-contact) > 00 V, min. Nominal current.7 A / 0 C Approvals - Basic standard: IEC RJ-, Category - CD ISO/IEC 80: 00 - EN 07: 00 - EIA/TIA 68B: 00

18 70-9 WAGO USB Service Cable 7 The WAGO USB Service Cable connects a PC (notebook) to either the service interface of the 87 Series Signal Conditioners and Relay Modules (JUMPFLE) or to WAGO- buscouplers/controllers. Notice: In connection with the fieldbus coupler: 70-8 as from firmware version 70-87/ as from firmware version Description WAGO USB Service Cable 70-9 USB specification.0 compatible/full-speed device Operating system Windows 98/000/P/VISTA Operating temperature - C C Interface USB type A/m Length. m Connector dimensions (WxHxD) x 0 x 9 mm Test voltage. kv, 0 Hz, min. Conformity marking Immy to interference EN EN Emission of interference EN 0

19 Port 00BASE-T Industrial Switch PWR RPS ALM Primary Power LED Redundant Power LED Alarm LED T port 00 Mbps LED T port LNK/ACT LED 6 T ports () 6 -port 0/00 Industrial Switch LNK/ACT The 8-0 Industrial Switch is a -port 0/00Base-T Ethernet switch. The switch has a rugged housing, a redundant power supply and function monitoring with relay, making it ideal for a wide range of applications. Features: Redundant DC power supply Wide supply voltage range: 9 V... 8 V DIP switch enables alarm functions Full compliance with IEEE80., 80.u stantards Non-blocking, store-and-forward switching Auto-negotiation on all 0/00BaseT ports Auto-MDI/MDI (crossover) on all 0/00BaseT ports Description -Port 00BASE-T Industrial Switch 8-0 Ports x 0/00Base-T (RJ-) Standards IEEE 80.u 00Base-T; IEEE 80. 0Base-T Maximum distances 0/00Base-T: 00 m voltage DC 9 V... 8 V (line length < 0 m) Operating temperature 0 C C Storage temperature -0 C C Relative air humidity (no condensation) 9 % Dimensions (mm) W x H x L 0 x 0 x 0 Weight approx. 780 g Vibration resistance acc. to IEC Shock resistance acc. to IEC Degree of protection IP 0 EMC -Immy to interference acc. to EN (00) EMC -Emission of interference acc. to EN (00)

20 8-0 8-Port 00BASE-T Industrial Switch 9 PWR RPS ALM Primary Power LED Redundant Power LED Alarm LED T port 00 Mbps LED T portlnk//act LED 8-0 0/ LNK/ACT 8-port 0/00 Industrial Switch The 8-0 Industrial Switch is an 8-port 0/00Base-T Ethernet switch. The switch has a rugged housing, a redundant power supply and function monitoring with relay, making it ideal for a wide range of applications. Features: Redundant DC power supply Large supply voltage range: 9 V... 8 V DIP switch enables alarm functions Full compliance with IEEE80., 80.u stantards Non-blocking, store-and-forward switching Auto-negotiation on all 0/00BaseT ports Auto-MDI/MDI (crossover) on all 0/00BaseT ports Description 8-Port 00BASE-T Industrial Switch 8-0 Ports 8 x 0/00Base-T (RJ-) Standards IEEE 80.u 00Base-T; IEEE 80. 0Base-T Throughputs,880/8,800 packets per second (pps) to 0/00 Mbps ports Maximum distances 0/00Base-T: 00 m voltage DC 9 V... 8 V (line length < 0 m) Operating temperature 0 C C Storage temperature -0 C C Relative air humidity (no condensation) 9 % Dimensions (mm) W x H x L 0 x 6 x 0 Weight approx. 780 g Vibration resistance acc. to IEC Shock resistance acc. to IEC Degree of protection IP 0 EMC -Immy to interference acc. to EN (00) EMC -Emission of interference acc. to EN (00)

21 Port 00BASE-T + -Slot 00BASE-F Industrial Switch PWR RPS ALM 00 LNK/ACT OFF LINE T 9 R 00 T 0 R 8-0 Primary Power LED Redundant Power LED Alarm LED T port 00 Mbps LED T port LNK/ACT LED 6 0/00 Base-T ports (8) 7 00 Base-F LC Fiber slots (SFP-type) () 8 Fiber port Offline LED () 9 Fiber port LNK/ACT LED () 0 Fiber port 00 Mbps LED () 0/ LNK/ACT 8-port 0/00+-port 00-F Industrial Switch The 8-0 Industrial Switch is an 8-port 0/00Base-T with dual SFP 00Base-F port (SFP modules are optional) Ethernet switch. The switch has a rugged housing, a redundant power supply and function monitoring with relay, making it ideal for a wide range of applications. Features: Redundant DC power supply Large supply voltage range: 9 V... 8 V DIP switch enables alarm functions Full compliance with IEEE80., 80.u stantards Non-blocking, store-and-forward switching Auto-negotiation on all 0/00BaseT ports Auto-MDI/MDI (crossover) on all 0/00BaseT ports Description 8/ Port 00BASE-T/F Industrial Switch 8-0 Accessories SFP Modules : 0nm, 00Base-F Multi-mode LC, km SFP Modules 0: 0nm, 00Base-F Single-mode LC, 0 km 8-0/ /07-00 Ports 8 x 0/00Base-T (RJ-); x SFP 00Base-F Fiber Standards IEEE 80.u 00Base-T/F; IEEE 80. 0Base-T Throughputs,880/8,800 packets per second (pps) to 0/00 Mbps ports Wavelength (optical fibers) depend on SFP module Maximum distances 0/00Base-T: 00 m; Fiber optic: up to 0 km voltage DC 9 V... 8 V (line length < 0 m) Operating temperature 0 C C Storage temperature -0 C C Relative air humidity (no condensation) 9 % Dimensions (mm) W x H x L 0 x 6 x 0 Weight approx. 780 g Vibration resistance acc. to IEC Shock resistance acc. to IEC Degree of protection IP 0 EMC -Immy to interference acc. to EN (00) EMC -Emission of interference acc. to EN (00)

22 8-0 7-Port 00BASE-T + -Slot 00BASE-F Industrial Managed Switch LNK/ACT T R 00 T PWR RPS ALM POST OFF LINE 8-0 LASER ON Reset 6 Primary Power LED Redundant Power LED Alarm LED POST LED LASER ON LED for fiber-optic modules 6 Reset button 7 T-port 00 Mbps LED 8 T-port LNK/ACT LED 9 RS- Console port (RJ-) 0 T-ports 0/00 Mbps (7) 00 Base-F LC Fiber slots (SFP-type) () Fiber 00 Mbps LED () Fiber port LNK/ACT LED () Fiber port Offline LED () R 00 0/ LNK/ACT CONSOLE 7-port 0/00+-port 00-F Managed Switch (RS-) The 8-0 Industrial Switch is a 7-port 0/00Base-T with dual SFP 00Base-F port (SFP modules are optional) configurable Ethernet switch. The switch has a rugged housing, a redundant power supply and function monitoring with relay. These functions along with extensive Ethernet switch options make it ideal for a wide range of applications. Features: Web-based/SNMP management Redundant DC power supply Large supply voltage range: 9 V... 8 V DIP switch enables alarm functions Full compliance with IEEE80., 80.u, 80.x,80.d, 80.q, 80.p standards press Ring (redundant ring recovery < 0 ms) Non-blocking, store-and-forward switching Auto-negotiation on all 0/00BaseT ports Auto-MDI/MDI (crossover) on all 0/00BaseT ports VLAN (80.q) VID IGMP Snooping for multicast filtering Port configuration, status, statistics Port Trunking SNMP v/v and RMON Description 7/-Port 00BASE-T/F Industrial Managed Switch Accessories SFP Modules : 0nm, 00Base-F Multi-mode LC, km SFP Modules 0: 0nm, 00Base-F Single-mode LC, 0 km / /07-00 Ports 7 x 0/00Base-T (RJ-); x SFP 00Base-F Fiber; x RS- (RJ-) Standards IEEE 80.u 00Base-T/F; IEEE 80.ad Port Trunking; IEEE 80. 0Base-T; IEEE 80.d Spanning Tree Protocol; IEEE 80.x Flow Control; IEEE 80.p Priority Queues; IEEE 80.q VLAN Tagging MAC table Up to K addresses VLANs Port-based and Tag-based (6VIDs) Throughputs,880/8,800 packets per second (pps) to 0/00 Mbps ports Wavelength (optical fibers) depend on SFP module Maximum distances 0/00Base-T: 00 m; Fiber optic: up to 0 km; RS-: m voltage DC 9 V... 8 V (line length < 0 m) Operating temperature 0 C C Storage temperature -0 C C Relative air humidity (no condensation) 9 % Dimensions (mm) W x H x L 0 x 6 x 0 Weight approx. 780 g Vibration resistance acc. to IEC Shock resistance acc. to IEC Degree of protection IP 0 EMC -Immy to interference acc. to EN (00) EMC -Emission of interference acc. to EN (00)

23 SFP Modules 00Base-F LC ELECTRICAL SUBASSEMBLY < 6,6 mm > < mm > T < 6, > R <, mm > DATA DATA/ T_DISABLE T_FAULT (0) () () DATA DATA/ R_LOS LD Driver & Fault Sense MOD_DEF LASER OPTICAL SUB- ASSEMBLIES PRE- AMPLIFIER IC xxx Diode Description SFP Module : 0nm, 00Base-F Multi-mode LC, km SFP Module 0: 0nm, 00Base-F Single-mode LC, 0 km Characteristics: Duplex LC optical connector; Industry standard small form pluggable (SFP) package; Compliant with Fast Ethernet standard; Differential LVPECL inputs and outputs; Single.V power supply; TTL signal detect indicator; Hot pluggable capability Connector Duplex LC Wavelength 0 nm Fiber type Multi-mode 6./ µm, 0/ µm Maximum distances 000 m Operating temperature 0 C C Storage temperature -0 C C Dimensions (mm) W x H x D. x. x 6.6 Laser Class acc. to EN 608- Connector Duplex LC Wavelength 0 nm Fiber type Single-mode 9/ µm, 0/ µm Maximum distances 000 m Operating temperature 0 C C Storage temperature -0 C C Dimensions (mm) W x H x D. x. x 6.6 Laser Class acc. to EN / /07-00

24

25 76-xx TO-PASS TM Telecontrol Module S Wireless fault detector and telecontrol module Compact telecontrol module for fault detection/indication and Internet connectivity for machines and installations over a GSM network. The module can be used worldwide via an integrated quad-band GSM modem. Messages are sent via SMS, , fax or phone call. In addition, the process image can be transmitted in an adjustable cycle to a user-selected Internet address. Switching of outputs is performed via SMS. digital inputs, digital outputs and analog inputs with integrated GSM modem. Ideal for applications in distributed stations for temperatures ranging from -0 C to +70 C. Ability to mount on DIN-rail and intuitive user software make easy to handle. Operating voltage ranges from 8 to 6 VDC. Description Telecontrol Module S Telecontrol Module S AI 76-0 Telecontrol Module S WEB 76-0 Telecontrol Module S AI WEB 76-0 Accessories Antennas, USB adapter, GSM modem and power supply s Approvals Conformity marking see page 6 Special functions: Acknowledgment: Acknowledging any fault message Stand-by: Automatic remote switching of the stand-by service GPRS-dedicated line: Permanent online connection to the process on a WEB server or PC with fixed IP address (e.g., DSL connection) LED indicators: Continuous "Com" + "Busy" + "Run" LED: CSD connection/communication initialization phase approx. 0 sec. Continuous "Busy" + "Run" LED: Active mode "Run" LED Hz: Error "Run" LED 0. Hz: Ready for operation No. of inputs Digital ( V... V); Analog (0/ ma... 0 ma) No. of outputs Digital: contacts Number of receivers (PC, SMS, , phone, fax) Communication GSM quad-band Communication types SMS (bidirectional), telecommunication dial-up connection (CSD), GPRS Internet connection Operating voltage DC 8 V... 6 V Closed current ma Current during transmission < 600 ma Internal resistance (analog inputs) 0 Ω Max. input current ( V).6 ma Load of digital outputs AC/DC 60 V/ A Operating temperature -0 C C Type of mounting TS Wire connection Terminal strips with push-wire connection (WAGO Series 0) Cross sections 0. mm².... mm² / AWG... Stripped lengths 9 mm /0. in Dimensions (mm) W x H x L 09 x 0 x 78 Weight.7 g Storage temperature -0 C C Degree of protection IP 0 EMC -Immy to interference acc. to EN (00)

26 76-xx TO-PASS TM Telecontrol Module M Telecontrol master for remote connection, telecontrol and monitoring Compact telecontrol module for fault detection/indication and Internet connectivity for machines and installations over a GSM network. The module can be used worldwide via an integrated quad-band GSM modem. Messages are sent via SMS, , fax or phone call. In addition, the process image can be transmitted in an adjustable cycle to a user-selected Internet address. Switching of outputs is performed via SMS. 8 digital inputs, 8 analog inputs, digital outputs and analog outputs with integrated GSM modem. Ideal for applications in distributed stations for temperatures ranging from -0 C to +70 C. Ability to mount on DIN-rail and intuitive user software make easy to handle. Operating voltage ranges from 8 to 6 VDC. Both event and data loggers are available as special functions. A Modbus participant (e.g., 70-86) can also be connected via RS- interface to link additional process values. Description Telecontrol Module M Telecontrol Module M 8AI 76-0 Telecontrol Module M 8AI ESP 76-0 Telecontrol Module M 8AI DSP 76-0 Telecontrol Module M 8AI ESP, DSP 76-0 Telecontrol Module M WEB MODBUS 76-0 Telecontrol Module M 8AI WEB MODBUS Accessories Antennas, USB adapter, GSM modem and power supply s Approvals Conformity marking see page 6 Special functions: Acknowledgment: Acknowledging any fault message Stand-by: Automatic remote switching of the stand-by service Remote parameterization: Programming and process visualization conveniently performed from the office Event logger: Saves all occurring status changes Data logger: Saves all process values with adjustable cycle GPRS-dedicated line: Permanent online connection to the process on a WEB server or PC with fixed IP address (e.g., DSL connection) LED indicators: Continuous "Com" + "Busy" + "Run" LED: CSD connection/communication initialization phase approx. 0 sec. Continuous "Busy" + "Run" LED: Active mode "Run" LED Hz: Error "Run" LED 0. Hz: Ready for operation No. of inputs Digital 8 ( V... V); Analog 8 (0/ ma... 0 ma) No. of outputs Digital: contacts, Analog: (0/ ma... 0 ma) Number of receivers (PC, SMS, , phone, fax) Communication GSM quad-band Communication types SMS (bidirectional), telecommunication dial-up connection (CSD), GPRS Internet connection Operating voltage DC 8 V... 6 V Closed current ma Current during transmission < 600 ma Internal resistance (analog inputs) 0 Ω Max. input current ( V).6 ma Load of digital outputs AC/DC 60 V/ A Operating temperature -0 C C Type of mounting TS Wire connection Terminal strips with push-wire connection (WAGO Series 0) Cross sections 0. mm².... mm² / AWG... Stripped lengths 9 mm /0. in Dimensions (mm) W x H x L 09 x 0 x 78 Weight.7 g Storage temperature -0 C C Degree of protection IP 0 EMC -Immy to interference acc. to EN (00)

27 6 Accessories for Telecontrol Modules, Series 76 Description Dipole antenna with. m cable Theft-proof antenna with. m cable Rod antenna, long Description Connection cable for rod antenna, 6 m long USB adapter with m connection cable Description Dual-band GSM modem incl. power supply Power supply /charge regulator V... 0 V AC to V DC A, also for battery operation Battery VDC. Ah lead-acid Description Outdoor enclosure TO-PASS TM Outdoor is a compact for the installation of TO-PASS TM telecontrol modules in an IP 66 enclosure with an integrated GSM antenna, 0 VAC to VDC power supply, power failure safety protection provided by batteries and terminal block connections for the supply of additional sensors.

28 79-90 TO-PASS TM Configuration Software 7 Software used to configure both 76-xx and 76-xx telecontrol modules. Compatible with Windows 000 and P. Communication to the modules via RS- port, USB port (via USB adapter, included in accessories) or external GSM modem (see accessories). Features: Intuitive parameterization of modules, without previous programming experience Display of current process values Line diagram for both data and event loggers Test of module's GSM received intensity Documentation and archival of configuration data Fast Copy function for the multiplication of configuration data German and English language interfaces Description Configuration software for 76-xx and 76-xx telecontrol modules System requirements: PC Pentium 00 MHz or faster Operating system Microsoft Windows 000 ; Microsoft Windows P Professional ; Microsoft Windows Vista Memory Min. 6 Mbytes (Windows P); Min. 0 Mbytes (Windows Vista) Hard disk storage Min. Mbytes CD-ROM required Graphics card GA or higher Mouse required Other Serial interface Included: CD ROM with software and documentation Additional requirements: Cable between PC communication interface and device. Windows is a registered trademark of Microsoft Corporation

29 08 IP67The New Performance Standard The trend toward decentralization requires increasingly powerful IP67 solutions. In addition to installing components directly on a machine (which saves space as well as overall switch cabinet costs), there is a growing need to divide installations into function s. This allows them to be jointly operated, while developing, testing, producing and extending them individually. This requires IP67 systems that are just as flexible and functional as current IP0 systems. Both the consideration and synergies resulting from these characteristics form the unique mechatronic basis for the WAGO SPEEDWAY 767. In addition to the features of a standard fieldbus component, a distributed programmable solution to IEC 6- has been created for demanding control and communication tasks.

30 Overview of system features 09 Short cycle times Expedites preprocessing and data transmission WAGO-DSC (Digital System Control) Improves the data transmission rate depending on the system requirements Synchrony Supplies time-synchronous collection and transmission of signals Safety feature Transmits safety-relevant data deep into the field level CoDeSys.x programmable (IEC6-) Provides signal pre-processing, relief of higher-level control systems and improved system availability FDT/DTM parameterization For multi-vendor device management Asynchronous and synchronous diagnostics Performs rapid, precise error analysis and reduces shutdown times USB interface Standardizes access during parameterization and programming Temperature range from C to +60 C Ideal for extreme environments IP67 degree of protection, fully encapsulated Ensures uncompromising safety in the harshest conditions Modular design Allows on-site signal acquisition and transmission according to user requirements Fieldbus independent Accommodates an increasingly wide variety of installation requirements Screw and DIN-rail mounting Enables the flexible installation of modules Excellent EMC protection Electromagnetic compatibility safeguards the application Effective power supply concept Conveniently powers modules Standard connection technology (Plug & Play) Supplies all components with easy and safe connections Ergonomic design Design clearly identifies all indications and markings

31 00 Improved features Performance WAGO-DSC (Digital System Control) Synchronous, highly accurate signal processing Cycle times < 00 µs Capacity Temperature range from C to +60 C IP67 degree of protection Excellent EMC protection Fully encapsulated Ergonomy

32 0 Functionality Integrated safety features Synchronous and asynchronous diagnostics Programmable and configurable Connectivity Open for all fieldbus systems Standard connection technology USB interface Innovative marking options Ergonomic design Variable mounting options

33 0 Improved data transmission WAGO-DSC (Digital System Control) Time-synchronous collection and transmission of signals Jitter/Skew < µs Low latency Example: digital signals < 00 µs * 6 analog signals < ms * digital signals and 8 analog signals < 0 µs * * Worst case (at a maximum total system extension of 00 meters) Cycle time [µsec] Digital Analog Number of signals _ + _ 0 00

34 Up to the physical limit 0 Modern ETHERNET-based fieldbus systems such as PROFINET, Powerlink and SERCOS III provide for data communication performance and an application range that greatly exceeds those found in standard PLC systems. The communication bottleneck between the fieldbus system and the sensors/actuators has been eliminated by improving the following four features of the remote WAGO SPEEDWAY 767 I/O system: WAGO-DSC (Digital System Control) Maximum speed up to the physical limit: Depending on the installation type, WAGO SPEEDWAY 767 can automatically determine the maximum data rate at startup and optimize set data transmission. Using speed control, the cycle times for installations with short cable runs can be reduced significantly as compared to the times stated in the Data Transmission Example. Even at a maximum extension of 00 meters, control loops, motion controls and rapid metering of signal acquisition can be performed via fieldbus. This results in considerably easier and less expensive automation solutions. Synchrony WAGO SPEEDWAY 767 also provides time-synchronous signal acquisition and transmission. This is completed by the trigger being sent to either the fieldbus system clock or to another external time base. Jitter/Skew Control algorithms can only be performed if the acquisition times are equidistant to the control variable. WAGO SPEEDWAY 767 has a jitter of < µs, which provides the highest levels of control quality. Triggering the signals (Skew), which are distributed over the whole system, is completed using the same precision of < µs. Latency In data communication, control and regulation delays are undesirable but theoretically inevitable. The WAGO SPEEDWAY 767 system latency is minimal and constant.

35 0 Improved, local signal acquisition/transmission Performance parameters Up to: 6 I/O modules per station 8 channels per module 0 channels per station 00 m total extension per station 0 m between two modules Fieldbus coupler/controller module System bus Spacer module Total Fieldbus USB interface Safety module

36 0 Consistently modular for maximum efficiency The system has a consistent modular design: I/O modules are used for the modular extension of fieldbus couplers and IEC6- programmable fieldbus couplers. Only two lines (communication, supply) are required for connecting the system, so that processing I/O signals can be directly performed on site, even when mounted in very different ways. When installed in areas of high signal concentration, the modules can be mounted in a horizontal and/or a vertical position for maximum space efficiency. Additionally, the 767's modularity ensures that the acquisition of a few, but widely distributed signals, can also be easily performed. Consider expensive field wiring or space-related problems in switch cabinets a thing of the past. extention 00 m Power distribution module Additional supply I/O module

37 FB 8 7 BF CS DIA PS ACT/LNK RES B/E 0I R/S 9I SI 8I ⁷ 7 ⁶ 6 ⁵ ⁴ ³ ² ¹ ⁰ 0 V U LS U A 767-xxxx I I I I I I I I I 06 WAGO SPEEDWAY 767 Dimensions and assembly dimensions Fieldbus coupler/programmable fieldbus coupler _> _>, > _> _> >,7, <,7 > < > < < 0, 08, 7 COM _> > > > < > < > 9 _> < 7 >, I/O module _> _>, > _> _> >,7, <_ 8, <_ < > < < 0, 08, 7 0 V U LS U A 767-xxxx _> > > > < > <,7 > 7,7 _> < 0 >, Power divider _> _>, > >, > >, <_ 8, <_ 6 < > < < 0, 08, 7 V U LS U A _> > > > < > <,7 > 7,7 _> < 0 >,

38 WAGO SPEEDWAY 767 General specifications 07 Materials: Enclosures Polyamide (PA) light gray (RAL70) Makrolon (address switch cover) transparent Flammability acc. to UL9-V0 halogen-, silicon-free Sealing Polyurethane (PUR) halogen-, silicon-free M8+M connectors M8x Ms nickel-plated tapped bush Mx Ms nickel-plated tapped bush CUSn6 contacts (Ni/Au surface) 0 mating cycles Viton seal Transportation and storage requirements: Free fall m IEC/EN Temperature -0 C C Relative humidity... 9 % without condensation Air pressure hpa m Operating conditions: Operating temperature C any fitting position Temperature change K/ s Air pressure hpa m Pollutant concentration SO: <0. ppm HS: <0. ppm Degree of pollution IEC6066 (IEC6) Protection class I IEC606 (VDE006, Part) Degree of protection IP 67 (NEMA 6&6P) DIN000 (EN609) Mechanical capacities: Vibration resistance acc. to IEC Shock resistance (temporary) acc. to IEC Continuous shock resistance acc. to IEC Impact resistance acc. to IEC Electromagnetic compatibility: Immy to interference acc. to EN Emission of interference acc. to EN

39 PROFIBUS DP/ V Fieldbus Coupler incl. 8 digital inputs (8 x M8) PROFIBUS PROFIBUS Input () PROFIBUS Output () LED indicators Operation panel RUN DIA CS BF BUS I RES I B/E 7I ⁶ 6I ⁶ I ⁴ I ³ I ² I ¹ I ⁰ FB System bus connection () Module marking Digital inputs () Channel marking USB connection () COM 0 V U LS U A output () input () PROFIBUS is a manufacturer-independent, open fieldbus standard for a wide range of automation applications. Its operation is based on the Master-Slave principle; communication with active participants is performed via Token Passing method. As a slave, the fieldbus coupler links the WAGO SPEEDWAY 767 System to PROFIBUS. When initializing, the buscoupler determines the station's module structure and creates a process image of all inputs and outputs. Device, module and channel diagnostics are supported according to the PROFIBUS standard. - 8 digital inputs DC V included - Modular and extendable up to 6 I/O modules (via system bus connection) - USB interface for servicing purposes - GSD or FDT/ DTM (incl. diagnostics and simulation) parameterization - Enclosed operation panel (operating mode and address switch) Included: WMB module marker card, yellow ( pcs) Channel marker strips ( pcs) M8 protective caps ( pcs) Description FC PROFIBUS DP 8DI V DC Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages Fieldbus: Type PROFIBUS DP/ V slave Wire connection () M connectors, B coded, poles ) Baud rate MBits/s (automatic recognition) Transmission medium Copper cable Address area 0-6 (adjustable by hardware) Additional data see PROFIBUS specification Module supply: Wire connection () M connectors, A coded, poles ) voltage Logic and sensor voltage V LS DC V (- % %) ) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. 0 ma + sensors (max. 00 ma) Actuator current I A ma Protection Reverse voltage protection for V LS + V A ; short circuit protection for sensor supply GSD files DTM (Device Type Manager) Download: Download: ) Derating must be observed ) Also required for power supply transmission

40 9 PROFIBUS Input Output M B coded Operation panel ON < Reset Boot / Execute ⁶ Address ⁵ ⁴ ³ ² ¹ ⁰ : + V * : Line A : GND * : Line B : Shield Housing: Shield *Internal signal Digital inputs... 8 M8 System bus connection M B coded : V : 0 V U LS : Input : TD+ : TD-- : RD-- : RD+ : GND Housing: Shield + Digital Input... 8 M8 70 pf Block diagram of an input 70 pf Input M Logic Error F USB COM M8 : + V : Data : +Data : GND Housing: Shield Input Output M A coded : V V LS : V V A : 0 V V LS : 0 V V A Module mount Digital inputs: No. of inputs 8 Wire connection () M8 connectors, poles Wire connection - to -wire Input filter parametrizable Input characteristic Type, acc. to IEC 6- Input circuit high-side switching Input voltage V DC (-0 V DC < V IN < +0 V DC) Input current typ..8 ma Cable length, unshielded 0 m Wrong connection of inputs No effect System bus: Number of expendable modules 6 Wire connection () M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus, fieldbus 00 V AC each Service: Type USB Wire connection () M8 connectors, poles Standards and approvals: PROFIBUS IEC68 r UL 08 Conformity marking Configurable functions: Fieldbus coupler see manual Digital inputs Input filter (per channel) 0./ 0./ / /0 ms/ filter off Online simulation (per channel) Lock/unlock; simulation value: 0/ Diagnostics (per channel) Overload and short circuit (sensor supply) Undervoltage (V LS + V A ) Process image: Input process image bytes Output process image bytes LED indicators: RUN: Coupler initialization LED (green/red) DIA: PROFIBUS diagnostics LED (red) CS: Coupler status LED (green/red) BF: PROFIBUS bus error LED (red) BUS: PROFIBUS projecting error LED (red) : Input status LED (yellow) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching General Specifications Dimensions (mm) W x H x L 7 x 7 x Weight approx. 0 g

41 PROFINET Fieldbus Coupler incl. 8 digital inputs (8 x M8) PROFINET PROFINET Input () PROFINET Input () LED indicators Operation panel BF CS DIA ACT/LNK I RES I B/E 9ISI 8I⁷ 7I ⁸ 6I ⁶ I ⁴ I ³ I ² I ¹ I ⁰ FB System bus connection () Module marking Digital inputs () Channel marking USB connection () COM 0 V U LS U A output () input () PROFINET is the innovative and open Industrial Ethernet standard for automation. PROFINET covers all requirements of automation technology. PROFINET offers solutions for manufacturing/process automation and safety applications in addition to covering an entire range of needs from drive technology to synchronous motion control applications. The fieldbus coupler links the WAGO SPEEDWAY 767 System to PROFINET. When initializing, the buscoupler determines the station's module structure and creates a process image of all inputs and outputs. The application protocol PROFINET IO is available for process data and the protocol services SNMP, DCP and LLDP for the system administration and diagnostics. - 8 digital inputs DC V included - Modular and extendable up to 6 I/O modules (via system bus connection) - USB Interface for servicing purposes - FDT/DTM (incl. diagnostics and simulation) parameterization - Enclosed operation panel (operating mode and address switch ) Included: WMB module marker card, yellow ( pcs) Channel marker strips ( pcs) M8 protective caps ( pcs) Description FC PROFINET 8DI V DC Fieldbus: Type Wire connection () Baud rate Transmission medium Device name PROFINET IO Device M connectors, D coded, poles 00 Mbits/s Copper cable Adjustable by hardware (or via DCP) Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages DTM (Device Type Manager) Download: Protocols PROFINET Additional data see PROFINET specification Module supply: Wire connection () M connectors, A coded, poles ) voltage Logic and sensor voltage V LS DC V (- % %) ) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. ma + sensors (max. 00 ma) Actuator current I A ma Protection Reverse voltage protection for V LS + V A ; short circuit protection for sensor supply ) Derating must be observed ) Also required for power supply transmission

42 PROFINET Input Input M D coded Operation panel ON < Reset Boot / Execute Set Network ⁷ Address ⁶ ⁵ ⁴ ³ ² ¹ ⁰ : TD+ : RD+ : TD : RD Housing: Shield Digital Input... 8 M8 M B coded System bus connection : V : 0 V U LS : Input : TD+ : TD-- : RD-- : RD+ : GND Housing: Shield + Digital Input... 8 M8 70 pf Block diagram of an input 70 pf Input M Logic Error F USB COM M8 : + V : Data : +Data : GND Housing: Shield Input Output M A coded : V V LS : V V A : 0 V V LS : 0 V V A Module mount Digital inputs: No. of inputs 8 Wire connection () M8 connectors, poles Wire connection - to -wire Input filter parametrizable Input characteristic Type, acc. to IEC 6- Input circuit high-side switching Input voltage V DC (-0 V DC < V IN < +0 V DC) Input current typ..8 ma Cable length, unshielded 0 m Wrong connection of inputs No effect System bus: Number of expendable modules 6 Wire connection () M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus, fieldbus 00 V AC each Service: Type USB Wire connection () M8 connectors, poles Standards and approvals: PROFINET IEC68 r UL 08 Conformity marking Configurable functions: Fieldbus coupler see manual Digital inputs Input filter (per channel) 0./ 0./ / /0 ms/ filter off Online simulation (per channel) Lock/unlock; simulation value: 0/ Diagnostics (per channel) Overload and short circuit (sensor supply) Undervoltage (V LS + V A ) Process image: Input process image bytes Output process image bytes LED indicators: BF: PROFINET bus error LED (red) ACT/LNK : PROFINET network LED (green/red) connection CS: Coupler status LED (green/red) DIA: PROFINET diagnostics LED (red) ACT/LNK : PROFINET data LED (green/red) exchange : Input status LED (yellow) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching General Specifications Dimensions (mm) W x H x L 7 x 7 x Weight approx. 0 g

43 767-0 EtherNet Fieldbus Coupler incl. 8 digital inputs (8 x M8) EtherNet EtherNet Input () EtherNet Input () LED indicators Operation panel MS CS NS ACT/LNK I RES I B/E 9ISN 8I⁷ 7I ⁸ 6I ⁵ I ⁴ I ³ I ² I ¹ I ⁰ FB System bus connection () Module marking Digital inputs () Channel marking USB connection () COM 0 V U LS U A output () input () In addition to ModBus-TCP, the EtherNet/IP protocol has proven itself as an industrial communication standard over Ethernet. The fieldbus coupler links the WAGO SPEEDWAY 767 System to EtherNet. When initializing, the buscoupler determines the module structure of the station, to create a process image of all inputs and outputs. The application protocols ModBus-TCP and EtherNet/IP are available for process data and the protocol services Http, BootP, DHCP, DNS, SNTP, FTP and SNMP (on request) for the system administration and diagnostics. - 8 digital inputs DC V included - Modular and extendable up to 6 I/O modules (via system bus connection) - USB Interface for servicing purposes - FDT/DTM (incl. diagnostics and simulation) parameterization - Enclosed operation panel (operating mode and address switch) Included: WMB module marker card, yellow ( pcs) Channel marker strips ( pcs) M8 protective caps ( pcs) Description FC EtherNet 8DI V DC Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages DTM (Device Type Manager) Download: Fieldbus: Type EtherNet Wire connection () M connectors, D coded, poles Baud rate 0/00 Mbits/s Transmission medium Copper cable Address area - adjustable by hardware (last byte of IP address) Protocols ModBus/ TCP (UDP), EtherNet/ IP Module supply: Wire connection () M connectors, A coded, poles ) voltage Logic and sensor voltage V LS DC V (- % %) ) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. ma + sensors (max. 00 ma) Actuator current I A ma Protection Reverse voltage protection for V LS + V A ; short circuit protection for sensor supply ) Derating must be observed ) Also required for power supply transmission

44 EtherNet Input Input M D coded Operation panel ON < Reset Boot / Execute Set Network ⁷ Address ⁶ ⁵ ⁴ ³ ² ¹ ⁰ : T+ : R+ : T : R Housing: Shield Digital Inputs... 8 M8 System bus connection M B coded : V : 0 V U LS : Input : TD+ : TD-- : RD-- : RD+ : GND Housing: Shield + Digital Input... 8 M8 70 pf Block diagram of an input 70 pf Input M Logic Error F USB COM M8 : + V : Data : +Data : GND Housing: Shield Input Output M A coded : V V LS : V V A : 0 V V LS : 0 V V A Module mount Digital inputs: No. of inputs 8 Wire connection () M8 connectors, poles Wire connection - to -wire Input filter parametrizable Input characteristic Type, acc. to IEC 6- Input circuit high-side switching Input voltage V DC (-0 V DC < V IN < +0 V DC) Input current typ..8 ma Cable length, unshielded 0 m Wrong connection of inputs No effect System bus: Number of expendable modules 6 Wire connection () M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus, fieldbus 00 V AC each Service: Type USB Wire connection () M8 connectors, poles Standards and approvals: r UL 08 Conformity marking Configurable functions: Fieldbus coupler see manual Digital inputs Input filter (per channel) 0./ 0./ / /0 ms/ filter off Online simulation (per channel) Lock/unlock; simulation value: 0/ Diagnostics (per channel) Overload and short circuit (sensor supply) Undervoltage (V LS + V A ) Process image: Input process image 08 bytes Output process image 08 bytes LED indicators: MS: EtherNet module status LED (green/red) ACT/LNK : EtherNet data LED (green) exchange/network connection CS: Coupler status LED (green/red) NS: EtherNet network status LED (green/red) ACT/LNK : EtherNet data LED (green) exchange/network connection : Input status LED (yellow) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching General Specifications Dimensions (mm) W x H x L 7 x 7 x Weight approx. 0 g

45 767-0 DeviceNet Fieldbus Coupler incl. 8 digital inputs (8 x M8) DeviceNet DeviceNet Input () DeviceNet Output () LED indicators Operation panel MS NS IO MBO CS I RES I B/E 9IBR 8I 7I⁶ 6I ⁵ I ⁴ I ³ I ² I ¹ I ⁰ FB System bus connection () Module marking Digital inputs () Channel marking USB connection () COM 0 V U LS U A output () input () DeviceNet is a manufacturer-independent, open CAN-based fieldbus protocol typically used for networking sensors and actuators with higher-level automation devices. It operates in both master-slave and multi-master modes, while active participants communicate via a point-to-point or a multipoint connection. As a slave, the fieldbus coupler links the WAGO SPEEDWAY 767 System to DeviceNet. When initializing, the buscoupler determines the station's module structure and creates a process image of all inputs and outputs. - 8 digital inputs DC V included - Extendable in a modular way up to 6 I/O modules (via system bus connection) - USB Interface for servicing purposes - FDT/DTM (incl. diagnostics and simulation) parameterization - Sealable operation panel (operating mode and address switch ) Included: WMB module marker card, yellow ( pcs) Channel marker strips ( pcs) M8 protective caps ( pcs) Description FC DeviceNet 8DI V DC Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages Fieldbus: Type DevieNet Slave Wire connection () M connectors, A coded, poles Baud rate / 0/ 00 Kbits/s Transmission medium Copper cable Address area -6 (adjustable by hardware) Additional data see DeviceNet specification Module supply: Wire connection () M connectors, A coded, poles ) voltage Logic and sensor voltage V LS DC V (- % %) ) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. 80 ma + sensors (max. 00 ma) Actuator current I A ma Protection Reverse voltage protection for V LS + V A ; short circuit protection for sensor supply DTM (Device Type Manager) Download: ) Derating must be observed ) Also required for power supply transmission

46 DeviceNet Input Output M A coded Operation panel ON < Reset Boot / Execute DS Baudrate ⁵ ⁴ ³ Address ² ¹ ⁰ : Drain : V+ : V : CAN_H : CAN_L Housing: Shield Digital Inputs... 8 M8 System bus connection M B coded : V : 0 V U LS : Input : TD+ : TD-- : RD-- : RD+ : GND Housing: Shield + Digital Input... 8 M8 Block diagram of an input Input M Logic Error F 8 Off Off On On 7 Off On Off On 0 00 Auto KB KB KB 70 pf 70 pf USB COM M8 : + V : Data : +Data : GND Housing: Shield Input Output M A coded : V V LS : V V A : 0 V V LS : 0 V V A Module mount Digital inputs: No. of inputs 8 Wire connection () M8 connectors, poles Wire connection - to -wire Input filter parametrizable Input characteristic Type, acc. to IEC 6- Input circuit high-side switching Input voltage V DC (-0 V DC < V IN < +0 V DC) Input current typ..8 ma Cable length, unshielded 0 m Wrong connection of inputs No effect System bus: Number of expendable modules 6 Wire connection () M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus, fieldbus 00 V AC each Service: Type USB Wire connection () M8 connectors, poles Standards and approvals: DeviceNet IEC606-, EN0- r UL 08 Conformity marking Configurable functions: Fieldbus coupler see manual Digital inputs Input filter (per channel) 0./ 0./ / /0 ms/ filter off Online simulation (per channel) Lock/unlock; simulation value: 0/ Diagnostics (per channel) Overload and short circuit (sensor supply) Undervoltage (V LS + V A ) Process image: Input process image 08 bytes Output process image 08 bytes LED indicators: MS: DeviceNet module status LED (green/ red) NS: DeviceNet network status LED (green/ red) CS: Coupler status LED (green/red) IO: IO status LED (green/red) MBO: MAC-ID/Baud rate LED (orange) overwritten : Input status LED (yellow) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching General Specifications Dimensions (mm) W x H x L 7 x 7 x Weight approx. 0 g

47 CANopen Fieldbus Coupler incl. 8 digital inputs (8 x M8) CANopen CANopen Input () CANopen Output () LED indicators Operation panel RUN ERR CS R T I RES I B/E 9IBR 8I 7I⁶ 6I ⁵ I ⁴ I ³ I ² I ¹ I ⁰ FB System bus connection () Module marking Digital Inputs () Channel marking USB connection () COM 0 V U LS U A output () input () CANopen is an industrial fieldbus protocol based on the Controller Area Network (CAN) system. The fieldbus links the WAGO SPEEDWAY 767 System as a slave to CANopen. As a slave, the fieldbus coupler links the WAGO SPEEDWAY 767 System to CANopen. Data is transmitted using PDOs and SDOs. When initializing, the buscoupler determines the station's module structure and creates a process image of all inputs and outputs. The local process image is divided into two data zones containing the data received and the data to be sent. The process data is made available to the CANopen fieldbus. - 8 digital inputs DC V included - Modular and extendable up to 6 I/O modules (via system bus connection) - USB Interface for servicing purposes - FDT/DTM (incl. diagnostics and simulation) parameterization - Enclosed operation panel (operating mode and address switch) Included: WMB module marker card, yellow ( pcs) Channel marker strips ( pcs) M8 protective caps ( pcs) Description FC CANopen 8DI V DC Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages Fieldbus: Type CANopen slave Wire connection () M connectors, A coded, poles Baud rate / 00/ 000 Kbits/s Transmission medium Copper cable Address area -7 (adjustable by hardware) Additional data see CANopen specification Module supply: Wire connection () M connectors, A coded, poles ) voltage Logic and sensor voltage V LS DC V (- % %) ) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. 8 ma + sensors (max. 00 ma) Actuator current I A ma Protection Reverse voltage protection for V LS + V A ; short circuit protection for sensor supply DTM (Device Type Manager) Download: ) Derating must be observed ) Also required for power supply transmission

48 7 CANopen Input Output M A coded Operation panel ON < Reset Boot / Execute Baudrate ⁶ ⁵ ⁴ ³ Address ² ¹ ⁰ : CAN_SHILD : CAN_V+ : CAN_GND : CAN_H : CAN_L Housing: Shield Digital Inputs... 8 M8 System bus connection M B coded : V : 0 V U LS : Input : TD+ : TD-- : RD-- : RD+ : GND Housing: Shield + Digital Input... 8 M8 Block diagram of an input Input M Logic Error F 9 8 Off Off On On Off On Off On 00 Auto KB KB MB 70 pf 70 pf USB COM M8 : + V : Data : +Data : GND Housing: Shield Input Output M A coded : V V LS : V V A : 0 V V LS : 0 V V A Module mount Digital inputs: No. of inputs 8 Wire connection () M8 connectors, poles Wire connection - to -wire Input filter parametrizable Input characteristic Type, acc. to IEC 6- Input circuit high-side switching Input voltage V DC (-0 V DC < V IN < +0 V DC) Input current typ..8 ma Cable length, unshielded 0 m Wrong connection of inputs No effect System bus: Number of expendable modules 6 Wire connection () M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus, fieldbus 00 V AC each Service: Type USB Wire connection () M8 connectors, poles Standards and approvals: r UL 08 Conformity marking Configurable functions: Fieldbus coupler see manual Digital inputs Input filter (per channel) 0./ 0./ / /0 ms/ filter off Online simulation (per channel) Lock/unlock; simulation value: 0/ Diagnostics (per channel) Overload and short circuit (sensor supply) Undervoltage (V LS + V A ) Process image: Input process image bytes Output process image bytes LED indicators: RUN: CANopen status LED (green/ red) ERR: CANopen bus error LED (green/ red) CS: Coupler status LED (green/red) R: CANopen receiver buffer LED (red) T: CANopen transmit buffer LED (red) : Input status LED (yellow) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching General Specifications Dimensions (mm) W x H x L 7 x 7 x Weight approx. 0 g

49 PROFIBUS DP/ V Programmable Fieldbus Coupler incl. 8 digital inputs (8 x M8) PROFIBUS PROFIBUS Input () PROFIBUS Output () LED indicators Operation panel RUN DIA CS BF BUS PS I RES I B/E 0I R/S 7I ⁶ 6I ⁵ I ⁴ I ³ I ² I ¹ I ⁰ FB System bus connection () Module marking Digital Inputs () Channel marking USB connection () COM 0 V U LS U A output () input () PROFIBUS is a manufacturer-independent, open fieldbus standard for a wide range of automation applications. Its operation is based on the Master-Slave principle; communication with active participants is performed via Token Passing method. As a slave, the fieldbus coupler links the WAGO SPEEDWAY 767 System to PRO- FIBUS. When initializing, the buscoupler determines the station's module structure and creates a process image of all inputs and outputs. Device, module and channel diagnostics are supported according to the PROFIBUS standard. In addition, this fieldbus coupler is programmable to IEC6- and can thus relieve the central control system and fieldbus, reduce response times, define the operating mode in the event of failure (fieldbus failure) as well as divide complex applications into independent, functional s. - 8 digital inputs DC V included - Modular and extendable up to 6 I/O modules (via system bus connection) - USB Interface for servicing purposes - GSD or FDT/ DTM (incl. diagnostics and simulation) parameterization - Programming acc. to IEC6- - Enclosed operation panel (operating mode and address switch) Included: WMB module marker card, yellow ( pcs) Channel marker strips ( pcs) M8 protective caps ( pcs) Description PFC PROFIBUS DP 8DI V DC Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages GSD files DTM (Device Type Manager) Download: Download: Fieldbus: Type PROFIBUS DP/ V slave Wire connection () M connectors, B coded, poles Baud rate Mbits/s (automatic recognition) Transmission medium Copper cable Address area 0-6 (adjustable by hardware) Additional data see PROFIBUS specification Programming: WAGO-I/O-PRO Software CoDeSys.x IEC 6- IL, LD, FBD, ST, FC Module supply: Wire connection () M connectors, A coded, poles ) voltage Logic and sensor voltage V LS DC V (- % %) ) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. 0 ma + sensors (max. 00 ma) Actuator current I A ma Protection Reverse voltage protection for V LS + V A ; short circuit protection for sensor supply ) Derating must be observed ) Also required for power supply transmission

50 9 PROFIBUS Input Output M B coded Operation panel ON < Reset Boot / Execute Run / Stop ⁶ Address ⁵ ⁴ ³ ² ¹ ⁰ : + V * : Line A : GND * : Line B : Shield Housing: Shield *Internal signal Digital Inputs... 8 M8 System bus connection M B coded : V : 0 V U LS : Input : TD+ : TD-- : RD-- : RD+ : GND Housing: Shield + Digital Input... 8 M8 70 pf Block diagram of an input 70 pf Input M Logic Error F USB COM M8 : + V : Data : +Data : GND Housing: Shield Input Output M A coded : V V LS : V V A : 0 V V LS : 0 V V A Module mount Digital inputs: No. of inputs 8 Wire connection () M8 connectors, poles Wire connection - to -wire Input filter parametrizable Input characteristic Type, acc. to IEC 6- Input circuit high-side switching Input voltage V DC (-0 V DC < V IN < +0 V DC) Input current typ..8 ma Cable length, unshielded 0 m Wrong connection of inputs No effect System bus: Number of expendable modules 6 Wire connection () M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus, fieldbus 00 V AC each Service: Type USB Wire connection () M8 connectors, poles Standards and approvals: PROFIBUS IEC68 r UL 08 Conformity marking Configurable functions: Fieldbus coupler see manual Digital inputs Input filter (per channel) 0./ 0./ / /0 ms/ filter off Online simulation (per channel) Lock/unlock; simulation value: 0/ Diagnostics (per channel) Overload and short circuit (sensor supply) Undervoltage (V LS + V A ) Process image: Input process image bytes Output process image bytes Input variables bytes Output variables bytes Program memory 0 Kbytes Data memory 6 Kbytes Remanent memory Kbytes (0 Kbytes retain, Kbytes flag) LED indicators: RUN: Coupler initialization LED (green/red) DIA: PROFIBUS diagnostics LED (red) CS: Controller status LED (green/ red) BF: PROFIBUS bus error LED (red) BUS: PROFIBUS projecting error LED (red) PS: Program status LED (green/red) : Input status LED (yellow) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching General Specifications Dimensions (mm) W x H x L 7 x 7 x Weight approx. 0 g

51 EtherNet Programmable Fieldbus Coupler incl. 8 digital inputs (8 x M8) EtherNet EtherNet Input () EtherNet Input () LED indicators Operation panel MS CS NS PS ACT/LNK I RES I B/E 0I R/S 9ISN 8I⁷ 7I ⁶ 6I ⁵ I ⁴ I ³ I ² I ¹ I ⁰ FB System bus connection () Module marking Digital inputs () Channel marking USB connection () COM 0 V U LS U A output () input () In addition to ModBus-TCP, the EtherNet/IP protocol has proven itself as an industrial communication standard over Ethernet. The fieldbus coupler links the WAGO SPEEDWAY 767 System to EtherNet. When initializing, the buscoupler determines the station's module structure and creates a process image of all inputs and outputs. The application protocols ModBus-TCP and EtherNet/IP are available for process data and the protocol services Http, BootP, DHCP, DNS, SNTP, FTP and SNMP (on request) for the system administration and diagnostics. In addition, this fieldbus coupler is programmable to IEC6- and can thus relieve the central control system and fieldbus, reduce response times, define the operating mode in the event of failure (fieldbus failure) as well as divide complex applications into independent, functional s. Description PFC EtherNet 8DI V DC Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages DTM (Device Type Manager) Download: digital inputs DC V included - Modular and extendable up to 6 I/O modules (via system bus connection) - USB Interface for servicing purposes - FDT/DTM (incl. diagnostics and simulation) parameterization - Programming acc. to IEC6- - Enclosed operation panel (operating mode and address switch) Included: WMB module marker card, yellow ( pcs) Channel marker strips ( pcs) M8 protective caps ( pcs) Fieldbus: Type EtherNet Wire connection () M connectors, D coded, poles Baud rate 0/ 00 Mbits/s Transmission medium Copper cable Address area - adjustable by hardware (last byte of IP address) Protocols ModBus/ TCP (UDP), EtherNet/ IP Programming: WAGO-I/O-PRO Software CoDeSys.x IEC 6- IL, LD, FBD, ST, FC Module supply: Wire connection () M connectors, A coded, poles ) voltage Logic and sensor voltage V LS DC V (- % %) ) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. ma + sensors (max. 00 ma) Actuator current I A ma Protection Reverse voltage protection for V LS + V A ; short circuit protection for sensor supply ) Derating must be observed ) Also required for power supply transmission

52 EtherNet Input Input M D coded Operation panel ON < Reset Boot / Execute Run / Stop Set Network ⁷ Address ⁶ ⁵ ⁴ ³ ² ¹ ⁰ : T+ : R+ : T : R Housing: Shield Digital Inputs... 8 M8 System bus connection M B coded : V : 0 V U LS : Input : TD+ : TD-- : RD-- : RD+ : GND Housing: Shield + Digital Input... 8 M8 70 pf Block diagram of an input 70 pf Input M Logic Error F USB COM M8 : + V : Data : +Data : GND Housing: Shield Input Output M A coded : V V LS : V V A : 0 V V LS : 0 V V A Module mount Digital inputs: No. of inputs 8 Wire connection () M8 connectors, poles Wire connection - to -wire Input filter parametrizable Input characteristic Type, acc. to IEC 6- Input circuit high-side switching Input voltage V DC (-0 V DC < V IN < +0 V DC) Input current typ..8 ma Cable length, unshielded 0 m Wrong connection of inputs No effect System bus: Number of expendable modules 6 Wire connection () M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus, fieldbus 00 V AC each Service: Type USB Wire connection () M8 connectors, poles Standards and approvals: r UL 08 Conformity marking Configurable functions: Fieldbus coupler see manual Digital inputs Input filter (per channel) 0./ 0./ / /0 ms/ filter off Online simulation (per channel) Lock/unlock; simulation value: 0/ Diagnostics (per channel) Overload and short circuit (sensor supply) Undervoltage (V LS + V A ) Process image: Input process image 08 bytes Output process image 08 bytes Input variables bytes Output variables bytes Program memory 0 Kbytes Data memory 6 Kbytes Remanent memory Kbytes (0 Kbytes retain, Kbytes flag) LED indicators: MS: EtherNet module status LED (green/red) ACT/LNK : EtherNet data LED (green) exchange/network connection CS: Controller status LED (green/ red) NS: EtherNet network status LED (green/red) ACT/LNK : EtherNet data LED (green) exchange/network connection PS: Program status LED (green/red) : Input status LED (yellow) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching General Specifications Dimensions (mm) W x H x L 7 x 7 x Weight approx. 0 g

53 767-0 CANopen Programmable Fieldbus Coupler incl. 8 digital inputs (8 x M8) CANopen CANopen Input () CANopen Output () LED indicators Operation panel RUN ERR CS R T PS I RES I B/E 0IR/S 9IBR 8I 7I⁶ 6I ⁵ I ⁴ I ³ I ² I ¹ I ⁰ FB System bus connection () Module marking Digital inputs () Channel marking USB connection () COM 0 V U LS U A output () input () CANopen is an industrial fieldbus protocol based on the Controller Area Network (CAN) system. The fieldbus links the WAGO SPEEDWAY 767 System as a slave to CANopen. Data is transmitted using PDOs and SDOs. When initializing, the buscoupler determines the station's module structure and creates a process image of all inputs and outputs. The local process image is divided into two data zones containing: data received and data to be sent. The process data is available to the CANopen fieldbus. In addition, this fieldbus coupler is programmable to IEC6- and can thus relieve the central control system and fieldbus, reduce response times, define the operating mode in the event of failure (fieldbus failure) as well as divide complex applications into independent, functional s. - 8 digital inputs DC V included - Modular and extendable up to 6 I/O modules (via system bus connection) - USB Interface for servicing purposes - FDT/DTM (incl. diagnostics and simulation) parameterization - Programming acc. to IEC6- - Enclosed operation panel (operating mode and address switch) Included: WMB module marker card, yellow ( pcs) Channel marker strips ( pcs) M8 protective caps ( pcs) Description PFC CANopen 8DI V DC Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages DTM (Device Type Manager) Download: Fieldbus: Type CANopen slave Wire connection () M connectors, A coded, poles Baud rate / 00/ 000 Kbits/s Transmission medium Copper cable Address area -7 (adjustable by hardware) Additional data see CANopen specification Programming: WAGO-I/O-PRO Software CoDeSys.x IEC 6- IL, LD, FBD, ST, FC Module supply: Wire connection () M connectors, A coded, poles ) voltage Logic and sensor voltage V LS DC V (- % %) ) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. 8 ma + sensors (max. 00 ma) Actuator current I A ma Protection Reverse voltage protection for V LS + V A ; short circuit protection for sensor supply ) Derating must be observed ) Also required for power supply transmission

54 CANopen Input Output M A coded Operation panel ON < Reset Boot / Execute Run / Stop Baudrate ⁶ ⁵ ⁴ ³ Address ² ¹ ⁰ : CAN_SHILD : CAN_V+ : CAN_GND : CAN_H : CAN_L Housing: Shield Digital Inputs... 8 M8 System bus connection M B coded : V : 0 V U LS : Input : TD+ : TD-- : RD-- : RD+ : GND Housing: Shield + Digital Input... 8 M8 Block diagram of an input Input M Logic Error F 9 8 Off Off On On Off On Off On 00 Auto KB KB MB 70 pf 70 pf USB COM M8 : + V : Data : +Data : GND Housing: Shield Input Output M A coded : V V LS : V V A : 0 V V LS : 0 V V A Module mount Digital inputs: No. of inputs 8 Wire connection () M8 connectors, poles Wire connection - to -wire Input filter parametrizable Input characteristic Type, acc. to IEC 6- Input circuit high-side switching Input voltage V DC (-0 V DC < V IN < +0 V DC) Input current typ..8 ma Cable length, unshielded 0 m Wrong connection of inputs No effect System bus: Number of expendable modules 6 Wire connection () M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus, fieldbus 00 V AC each Service: Type USB Wire connection () M8 connectors, poles Standards and approvals: r UL 08 Conformity marking Configurable functions: Fieldbus coupler see manual Digital inputs Input filter (per channel) 0./ 0./ / /0 ms/ filter off Online simulation (per channel) Lock/unlock; simulation value: 0/ Diagnostics (per channel) Overload and short circuit (sensor supply) Undervoltage (V LS + V A ) Process image: Input process image bytes Output process image bytes Input variables bytes Output variables bytes Program memory 0 Kbytes Data memory 6 Kbytes Remanent memory Kbytes (0 Kbytes retain, Kbytes flag) LED indicators: RUN: CANopen status LED (green/ red) ERR: CANopen bus error LED (green / red) CS: Controller status LED (green/ red) R: CANopen receiver buffer LED (red) T: CANopen transmit buffer LED (red) PS: Program status LED (green/red) : Input status LED (yellow) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching General Specifications Dimensions (mm) W x H x L 7 x 7 x Weight approx. 0 g

55 Digital Input Module V DC 8 inputs (8 x M8) Module marking LED indicators System bus output () System bus input () Digital inputs () Channel marking 0 V U LS U A output () input () Digital input module records binary signals from switches, sensors and proximity switches (BEROs). - 8 digital inputs DC V - Diagnostic capable - Parametrizable (filter, online simulation and diagnostics) Included: WMB module marker card, yellow ( pcs) Marker strips ( pcs) M8 protective caps ( pcs) Description 8DI V DC (8xM8) Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages Module supply: Wire connection () M connectors, A coded, poles ) voltage Logic and sensor voltage V LS DC V (- % %) ) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. 0 ma + sensors (max. 00 ma) Actuator current I A ma Protection Reverse voltage protection for V LS + V A ; short circuit protection for sensor supply Digital inputs: No. of inputs 8 Wire connection () M8 connectors, poles Wire connection - to -wire Input filter parametrizable Input characteristic Type, acc. to IEC 6- Input circuit high-side switching Input voltage V DC (-0 V DC < V IN < +0 V DC) Input current typ. 7. ma Connection of -wire BEROs max.. ma admissible closed current Cable length, unshielded 0 m Wrong connection of inputs No effect ) Derating must be observed ) Also required for power supply transmission

56 System bus Input Output M B coded Digital Inputs... 8 M8 : RD+/TD+ : RD--/TD-- : TD--/RD-- : TD+/RD+ : GND Housing: Shield : V : 0 V V LS : Input + Digital Input... 8 M8 Block diagram of an input Input M Logic Error F 70 pf 70 pf Input Output : V V LS : V V A : 0 V V LS : 0 V V A Module mount M A coded Input characteristic: Input voltage Typical input current -0 V DC < V IN < 0 V DC 0. ma 6. ma 7. ma 0 7. ma System bus: Wire connection () Standards and approvals: r UL 08 Conformity marking M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus 00 V AC each Configurable functions: Input filter (per channel) 0./ 0./ / /0 ms/ filter off Online simulation (per channel) Lock/unlock; simulation value: 0/ Diagnostics (per channel) Overload and short circuit (sensor supply) Undervoltage (V LS + V A ) Process image: Process data width -byte data + status LED indicators: : Input status LED (yellow) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching General Specifications Dimensions (mm) W x H x L 0 x 7 x Weight approx. 0 g

57 Digital Input Module V DC 8 inputs ( x M - two inputs per connector) Module marking System bus output () System bus input () LED indicators 6 7 Digital inputs () 0 Channel marking V U LS U A output () input () Digital input module records binary signals from switches, sensors and proximity switches (BEROs). - 8 digital inputs DC V - Diagnostic capable - Parametrizable (filter, online simulation and diagnostics) Included: WMB module marker card, yellow ( pcs) Marker strips ( pcs) M protective caps ( pcs) Description 8DI V DC (xm) Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages Module supply: Wire connection () M connectors, A coded, poles ) voltage Logic and sensor voltage V LS DC V (- % %) ) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. 0 ma + sensors (max. 00 ma) Actuator current I A ma Protection Reverse voltage protection for V LS + V A ; short circuit protection for sensor supply Digital inputs: No. of inputs 8 Wire connection () M connectors, A coded, poles Wire connection - to -wire Input filter parametrizable Input characteristic Type, acc. to IEC 6- Input circuit high-side switching Input voltage V DC (-0 V DC < V IN < +0 V DC) Input current typ. 7. ma Connection of -wire BEROs max.. ma admissible closed current Cable length, unshielded 0 m Wrong connection of inputs No effect ) Derating must be observed ) Also required for power supply transmission

58 7 System bus Input Output M B coded Digital Inputs... (two intputs/connector) M A coded : RD+/TD+ : RD--/TD-- : TD--/RD-- : TD+/RD+ : GND Housing: Shield : V : 0 V V LS : n.c. : Input A : Input B + + Digital Input... M / 70 pf Block diagram of an input 70 pf Input M Logic Error F Input Output : V V LS : V V A : 0 V V LS : 0 V V A Module mount M A coded Input characteristic: Input voltage Typical input current -0 V DC < V IN < 0 V DC 0. ma 6. ma 7. ma 0 7. ma System bus: Wire connection () Standards and approvals: r UL 08 Conformity marking M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus 00 V AC each Configurable functions: Input filter (per channel) 0./ 0./ / /0 ms/ filter off Online simulation (per channel) Lock/unlock; simulation value: 0/ Diagnostics (per channel) Overload and short circuit (sensor supply) Undervoltage (V LS + V A ) Process image: Process data width -byte data + status LED indicators: : Input status LED (yellow) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching General Specifications Dimensions (mm) W x H x L 0 x 7 x Weight approx. 0 g

59 Digital Output Module V DC / 0. A 8 outputs (8 x M8) Module marking LED indicators System bus output () System bus input () Digital outputs () Channel marking 0 V U LS U A output () input () Digital output module for actuator control (e.g., magnetic valves, DC contactors, indicators). - 8 digital outputs DC V / 0. A - Diagnostic capable - Parametrizable (substitute values, online simulation and diagnostics) Included: WMB module marker card, red ( pcs) Marker strips ( pcs) M8 protective caps ( pcs) Description 8DO V DC 0.A (8xM8) Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages Module supply: Wire connection () M connectors, A coded, poles ) Current carrying capacity of supply connections max. 8 A (V LS : A, V A : A) voltage Logic and sensor voltage V LS DC V (- % %) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. ma (only logic part) Actuator current I A typ. ma + actuators Protection Reverse voltage protection for V LS + V A Digital outputs: No. of outputs 8 Wire connection () M8 connectors, poles Wire connection - to -wire Output voltage V A Output current (per channel) 0. A (max. 0.6 A), short-circuit/overload proof (thermal disconnection) Voltage drop against V A at 00 ma approx. 0. V DC Output current (module) max. A Leakage current when switched off typ. 0 µa Switching on of overload circuit parametrizable Output circuit high-side switching ) Derating must be observed

60 9 System bus Input Output M B coded Digital Outputs... 8 : RD+/TD+ : RD--/TD-- : TD--/RD-- : TD+/RD+ : GND Housing: Shield : V V A : 0 V V A Digital Output... 8 M8 Block diagram of an output M + Logic 0 nf 0 nf M8 : Output 70 pf Input Output : V V LS : V V A : 0 V V LS : 0 V V A Output Error F Module mount M A coded Information on selecting the actuor: Rise time from "0" to "" from "" to "0" typ. 0 µs (resistive load) typ. 0 µs (resistive load) Line length 0 m Resistance to reverse voltages on request Type of load Inductive, resistive loads and lamps Switching frequency Inductive load approx. 0 Hz Resistive load approx. 00 Hz Lamp load approx. 00 Hz Type of protective circuit External protection (e.g., recovery diodes) required Output resistance < 0. Ω Influence of operating states on output: CPU stop of PLC Acc. to substitute value strategy voltage under rated voltage tolerance 0 V status Interruption of supply voltage 0 V status Procedure of output Behavior in case of overload System bus: Wire connection () non-latching Auto restart M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus 00 V AC each Configurable functions: Substitute value strategy (per channel) Switch substitute value / hold last value Substitute value (per channel) 0 / (Default: 0) Online simulation (per channel) Lock/unlock; simulation value: 0/ Diagnostics (per channel) (per module) Overload and short circuit (actuators) Undervoltage (V LS + V A ) Process image: Process data width -byte data + status LED indicators: : Output status LED (yellow / red) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching Standards and approvals: r UL 08 Conformity marking General Specifications Dimensions (mm) W x H x L 0 x 7 x Weight approx. 0 g

61 Digital Output Module V DC / 0. A 8 outputs ( x M - two outputs per connector) Module marking System bus output () System bus input () LED indicators 6 7 Digital outputs () 0 Channel marking V U LS U A output () input () Digital output module for actuator control (e.g., magnetic valves, DC contactors, indicators). - 8 digital outputs DC V / 0. A - Diagnostic capable - Parametrizable (substitute values, online simulation and diagnostics) Included: WMB module marker card, red ( pcs) Marker strips ( pcs) M protective caps ( pcs) Description 8DO V DC 0.A (xm) Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages Module supply: Wire connection () M connectors, A coded, poles ) Current carrying capacity of supply connections max. 8 A (V LS : A, V A : A) voltage Logic and sensor voltage V LS DC V (- % %) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. ma (only logic part) Actuator current I A typ. ma + actuators Protection Reverse voltage protection for V LS + V A Digital outputs: No. of outputs 8 Wire connection () M connectors, A coded, poles Wire connection - to -wire Output voltage V A Output current (per channel) 0. A (max. 0.6 A), short-circuit/overload proof (thermal disconnection) Voltage drop against V A at 00 ma approx. 0. V DC Output current (module) max. A Leakage current when switched off typ. 0 µa Switching on of overload circuit parametrizable Output circuit high-side switching ) Derating must be observed

62 6 System bus Input Output M B coded Digital Outputs... (two outputs/connector) : RD+/TD+ : RD--/TD-- : TD--/RD-- : TD+/RD+ : GND Housing: Shield : V V A : 0 V V A Digital Output... M Block diagram of an output M : n.c. + + / Logic 0 nf 0 nf M A coded : Output A : Output B 70 pf Input Output : V V LS : V V A : 0 V V LS : 0 V V A Output Error F Module mount M A coded Information on selecting the actuor: Rise time from "0" to "" from "" to "0" typ. 0 µs (resistive load) typ. 0 µs (resistive load) Line length 0 m Resistance to reverse voltages on request Type of load Inductive, resistive loads and lamps Switching frequency Inductive load approx. 0 Hz Resistive load approx. 00 Hz Lamp load approx. 00 Hz Type of protective circuit External protection (e.g., recovery diodes) required Output resistance < 0. Ω Influence of operating states on output: CPU stop of PLC Acc. to substitute value strategy voltage under rated voltage tolerance 0 V status Interruption of supply voltage 0 V status Procedure of output Behavior in case of overload System bus: Wire connection () non-latching Auto restart M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus 00 V AC each Configurable functions: Substitute value strategy (per channel) Switch substitute value / hold last value Substitute value (per channel) 0 / (Default: 0) Online simulation (per channel) Lock/unlock; simulation value: 0/ Diagnostics (per channel) (per module) Overload and short circuit (actuators) Undervoltage (V LS + V A ) Process image: Process data width -byte data + status LED indicators: : Output status LED (yellow / red) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching Standards and approvals: r UL 08 Conformity marking General Specifications Dimensions (mm) W x H x L 0 x 7 x Weight approx. 0 g

63 Digital Output Module V DC /.0 A 8 outputs (8 x M8) Module marking LED indicators System bus output () System bus input () Digital outputs () Channel marking 0 V U LS U A input () input () Digital output module for actuator control (e.g., magnetic valves, DC contactors, indicators). - 8 digital outputs DC V /.0 A - Diagnostic capable - Parametrizable (substitute values, online simulation and diagnostics) Included: WMB module marker card, red ( pcs) Marker strips ( pcs) M protective caps ( pcs) Description 8DO V DC.0A (8xM8) Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages Module supply: Wire connection () M connectors, A coded, poles ) Current carrying capacity of both supply inputs max. 8 A ( x V A : A) voltage Logic and sensor voltage V LS DC V (- % %) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. ma (only logic part) Actuator current I A typ. ma + actuators Protection Reverse voltage protection for V LS + V A Digital outputs: No. of outputs 8 Wire connection () M8 connectors, poles Wire connection - to -wire Output voltage V A Output current (per channel).0 A (max.. A), short-circuit/overload proof (thermal disconnection) Voltage drop against V A at.0 A approx. 0. V DC Output current (module) max. 8 A Leakage current when switched off typ. 780 µa Switching on of overload circuit parametrizable Output circuit high-side switching ) Derating must be observed

64 6 System bus Input Output M B coded Digital Outputs... 8 : RD+/TD+ : RD--/TD-- : TD--/RD-- : TD+/RD+ : GND Housing: Shield : V V A : 0 V V A Digital Output... 8 M8 Block diagram of an output M + Logic 0 nf 0 nf M8 : Output 70 pf Input Output : V V LS : V V A : 0 V V LS : 0 V V A Output Error F Module mount M A coded Information on selecting the actuor: Rise time from "0" to "" from "" to "0" typ. 0 µs (resistive load) typ. 0 µs (resistive load) Line length 0 m Resistance to reverse voltages A Type of load Inductive, resistive loads and lamps Switching frequency Inductive load approx. 0 Hz Resistive load approx. 00 Hz Lamp load approx. 00 Hz Type of protective circuit External protection (e.g., recovery diodes) required Output resistance approx. 0. Ω Influence of operating states on output: CPU stop of PLC Acc. to substitute value strategy voltage under rated voltage tolerance 0 V status Interruption of supply voltage 0 V status Procedure of output Behavior in case of overload System bus: Wire connection () non-latching Auto restart M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus 00 V AC each Configurable functions: Substitute value strategy (per channel) Switch substitute value / hold last value Substitute value (per channel) 0 / (Default: 0) Online simulation (per channel) Lock/unlock; simulation value: 0/ Diagnostics (per channel) (per module) Overload and short circuit (actuators) Undervoltage (V LS + V A ) Process image: Process data width -byte data + status LED indicators: : Output status LED (yellow / red) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching Standards and approvals: r UL 08 Conformity marking General Specifications Dimensions (mm) W x H x L 0 x 7 x Weight approx. 0 g

65 Digital Output Module V DC /.0 A 8 outputs ( x M - two outputs per connector) Module marking System bus output () System bus input () LED indicators 6 7 Digital outputs () 0 Channel marking V U LS U A input () input () Digital output module for actuator control (e.g., magnetic valves, DC contactors, indicators). - 8 digital outputs DC V /.0 A - Diagnostic capable - Parametrizable (substitute values, online simulation and diagnostics) Included: WMB module marker card, red ( pcs) Marker strips ( pcs) M8 protective caps ( pcs) Description 8DO V DC.0A (xm) Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages Module supply: Wire connection () M connectors, A coded, poles ) Current carrying capacity of both supply inputs max. 8 A ( x V A : A) voltage Logic and sensor voltage V LS DC V (- % %) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. ma (only logic part) Actuator current I A typ. ma + actuators Protection Reverse voltage protection for V LS + V A Digital outputs: No. of outputs 8 Wire connection () M connectors, A coded, poles Wire connection - to -wire Output voltage V A Output current (per channel).0 A (max.. A), short-circuit/overload proof (thermal disconnection) Voltage drop against V A at.0 A approx. 0. V DC Output current (module) max. 8 A Leakage current when switched off typ. 780 µa Switching on of overload circuit parametrizable Output circuit high-side switching ) Derating must be observed

66 6 System bus Input Output M B coded Digital Outputs... (two outputs/connector) : RD+/TD+ : RD--/TD-- : TD--/RD-- : TD+/RD+ : GND Housing: Shield : V V A : 0 V V A Digital Output... M Block diagram of an output M : n.c. + + / Logic 0 nf 0 nf M A coded : Output A : Output B 70 pf Input Output : V V LS : V V A : 0 V V LS : 0 V V A Output Error F Module mount M A coded Information on selecting the actuor: Rise time from "0" to "" from "" to "0" typ. 0 µs (resistive load) typ. 0 µs (resistive load) Line length 0 m Resistance to reverse voltages A Type of load Inductive, resistive loads and lamps Switching frequency Inductive load approx. 0 Hz Resistive load approx. 00 Hz Lamp load approx. 00 Hz Type of protective circuit External protection (e.g., recovery diodes) required Output resistance approx. 0. Ω Influence of operating states on output: CPU stop of PLC Acc. to substitute value strategy voltage under rated voltage tolerance 0 V status Interruption of supply voltage 0 V status Procedure of output Behavior in case of overload System bus: Wire connection () non-latching Auto restart M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus 00 V AC each Configurable functions: Substitute value strategy (per channel) Switch substitute value / hold last value Substitute value (per channel) 0 / (Default: 0) Online simulation (per channel) Lock/unlock; simulation value: 0/ Diagnostics (per channel) (per module) Overload and short circuit (actuators) Undervoltage (V LS + V A ) Process image: Process data width -byte data + status LED indicators: : Output status LED (yellow / red) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching Standards and approvals: r UL 08 Conformity marking General Specifications Dimensions (mm) W x H x L 0 x 7 x Weight approx. 0 g

67 Analog Input Module Voltage/Current inputs Module marking System bus output () System bus input () LED indicators Ch Er Ch Er Ch Analog inputs () Ch Er Er Channel marking V U LS U A output () input () Analog input module records voltage and current signals. - analog inputs 0-0 ma, -0 ma, ±0 ma, 0-0 V or ±0 V - Diagnostic capable - Parametrizable (measuring range, operating mode, filter, limiting values, online simulation and diagnostics) Included: WMB module marker card, green ( pcs) Marker strips ( pcs) M protective caps ( pcs) Description AI V/I Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages Module supply: Wire connection () M connectors, A coded, poles ) voltage Logic and sensor voltage V LS DC V (- % %) ) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS ma + sensors (max. 00 ma) Actuator current I A ma Protection Reverse voltage protection for V LS + V A ; short circuit protection for sensor supply Analog inputs: No. of inputs Wire connection () M connectors, A coded, poles Type of signal Currents and voltages (differencial inputs) Wire connection - to -wire (external shield (screen) via knurled nut) Measuring range 0-0 ma, -0 ma, ±0 ma, 0-0 V, ±0 V Input impedance AI(V) 00 kω AI(I) 00 Ω Type of cable, cable length shielded, 0 m ) Derating must be observed ) Also required for power supply transmission

68 67 System bus Input Output M B coded Analog Inputs... : RD+/TD+ : RD--/TD-- : TD--/RD-- : TD+/RD+ : GND Housing: Shield : V V LS : Input + Analog Input... M Block diagram of an input A/D Logic M M A coded : Schield : Input - : 0 V V LS Housing: Shield + _ + _ Shield 0 nf 70 pf Ch... Er... Input Output : V V LS : V V A : 0 V V LS : 0 V V A Module mount M A coded Analog value creation: Resolution Method of conversion Monotonicity without error codes Conversion time Sampling delay Sampling time of repetition Failures and errors: Voltage proof Max. measuring error at C Temperature error Maximum error over the full temperature range Maximum temporary deviation Common mode rejection System bus: Wire connection () Standards and approvals: r UL 08 Conformity marking 6 bits SAR yes ms ms (module) < 00 µs (channel/channel) ms up to V (internal current limitation) approx. ± 0. % of the measuring range approx. ± 0.0 % of the measuring range on request on request yes M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus 00 V AC each Configurable functions: Measuring range (per channel) 0-0 ma, -0 ma, ±0 ma, 0-0 V, ±0 V Limiting values (per channel) (per channel) Lock/unlock Min/ Min/ Max/ Max Input filter (per channel) Low pass Sampling duration (per channel),,, 8 ms Interference frequency suppression (per channel) 0/60 Hz Online simulation (per channel) Lock/unlock; simulation value: (according to measuring range) Diagnostics (per module) (per module) (per channel) (per channel) (per channel) Short circuit (sensor power supply) Undervoltage (V LS + V A ) Wire break (-0 ma) Limit value violation Overrange/measuring range underflow Process image: Process data width 8-byte data + status LED indicators: Ch... Ch: Input status indicator LED (yellow) Er... Er: Input error indication LED (red) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching General Specifications Dimensions (mm) W x H x L 0 x 7 x Weight approx. 0 g

69 Analog Input Module RTD inputs Module marking System bus output () System bus input () LED indicators Ch Er Ch Er Ch Analog inputs () Ch Er Er Channel marking V U LS U A output () input () Analog input module records the values from resistance thermometers, resistors and potentiometer adjustment. - RTD analog inputs - Diagnostic capable - Parametrizable (measuring range, operating mode, filter, limiting values, online simulation and diagnostics) Included: WMB module marker card, green ( pcs) Marker strips ( pcs) M protective caps ( pcs) Description AI RTD Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages Module supply: Wire connection () M connectors, A coded, poles ) voltage Logic and sensor voltage V LS DC V (- % %) ) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. 0 ma Actuator current I A ma Protection Reverse voltage protection for V LS + V A Analog inputs: No. of inputs Wire connection () M connectors, A coded, poles Type of signal Resistance thermometers, resistors, potentiometers Wire connection -/-/-wire (external shield (screen) via knurled nut) Signal measuring range RTD Pt00, Pt00, Pt00, Pt000 Ni00, Ni0, Ni000 Resistances. kω and kω Potentiometer % setting angle (for. kω and kω) Free characteristics Pt000, NTC, etc. Temperature range Pt: -00 C C Ni: -60 C C Resolution (over whole range) 0. C / 0. Ω / 0.0 % Measuring current < 0. ma Type of cable, cable length shielded, 0 m ) Derating must be observed ) Also required for power supply transmission

70 69 System bus Input Output M B coded Analog Inputs... : RD+/TD+ : RD--/TD-- : TD--/RD-- : TD+/RD+ : GND Housing: Shield : R+ : RL+ Analog Input... M Block diagram of an input k M M A coded Input M A coded Output : Shield : RL - : R - Housing: Shield : V V LS : V V A : 0 V V LS : 0 V V A ϑ ϑ ϑ Shield 70 pf MU A/D Logic Ch... Er... Module mount Analog value creation: Resolution Input filter Method of conversion Monotonicity without error codes Conversion time Sampling time of repetition Linearizations Failures and errors: Max. measuring error at C Temperature error Maximum error over the full temperature range Maximum temporary deviation Repeat accuracy System bus: Wire connection () Isolation: Channel - Channel V LS, V A, system bus Standards and approvals: r UL 08 Conformity marking 6 bits 6,7 Hz, Hz, 0 Hz, 60 Hz, 0 Hz, 0 Hz, 00 Hz SigmaDelta yes / Input sampling frequency (s) Number of active channels x Conversion time x See free characteristic ± 0. % of the measuring range ± 0.00 % of the measuring range/ K on request on request on request M connectors, B coded, poles, shielded no 00 V AC each Configurable functions: Measuring range (per channel) (per channel) (per channel) Pt00/ Pt00/ Pt00/ Pt000, Ni00/ Ni0/ Ni000. kω / kω % setting angle (for. kω and kω) Pt000, NTC, separate characteristic (per channel) Wire connection (per channel) -wire/-wire/-wire Limiting values (per channel) Lock/unlock (per channel) Min/ Min/ Max/ Max Input filter (per channel) 6,7 Hz, Hz, 0 Hz, 60 Hz, 0 Hz, 0 Hz, 00 Hz Linearization (per channel) See free characteristic Online simulation (per channel) Lock/unlock; simulation value: (according to measuring range) Diagnostics (per module) (per channel) (per channel) (per channel) Undervoltage (V LS + V A ) Wire break Overrange/measuring range underflow Limit value violation Process image: Process data width 8-byte data + status LED indicators: Ch... Ch: Input status indicator LED (yellow) Er... Er: Input error indication LED (red) F: Fault status LED (red) V LS + V A : status LED (green) SB: System bus status LED (green/red) Indicators non-latching General Specifications Dimensions (mm) W x H x L 0 x 7 x Weight approx. 0 g

71 Analog Output Module Voltage/Current outputs Module marking System bus output () System bus input () LED indicators Ch Er Ch Er Ch Analog outputs () Ch Er Er Channel marking V U LS U A output () input () Analog output module for the output of voltage and current signals. - analog outputs 0-0 ma, -0 ma, ±0 ma, 0-0 V or ±0 V - Diagnostic capable - Parametrizable (measuring range, substitute value strategy, substitute values, online simulation and diagnostics) Included: WMB module marker card, blue ( pcs) Marker strips ( pcs) M protective caps ( pcs) Description AO V/I Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages Module supply: Wire connection () M connectors, A coded, poles ) voltage Logic and sensor voltage V LS DC V (- % %) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS 8 ma (only logic part) Actuator current I A ma + actuators Protection Reverse voltage protection for V LS + V A ; Overload and short circuit protection for V LS Analog outputs: No. of outputs Wire connection () M connectors, A coded, poles Type of signal Currents and voltages Wire connection - to -wire (external shield (screen) via knurled nut) Measuring range 0-0 ma, -0 ma, ±0 ma, 0-0 V, ±0 V Output load (load impedance) 00 Ω (current) kω (voltage) Maximum capacitive load (at voltage outputs) 0 nf Maximum inductive load (at current outputs) mh Type of cable, cable length shielded, 0 m ) Derating must be observed

72 7 System bus Input Output M B coded Analoge Outputs... : RD+/TD+ : RD--/TD-- : TD--/RD-- : TD+/RD+ : GND Housing: Shield : V : Output +/- Analog Output... M Block diagram of an output M M A coded : Schield : Output - : 0 V V A Housing: Shield + Ch.. Er.. Logic Input Output M A coded : V V LS : V V A : 0 V V LS : 0 V V A Error F Module mount Analog value creation: Resolution -bit unipolar, 6-bit bipolar Monotonicity yes Cycle time approx. ms Recovery time for resistive, inductive and capacitive loads approx. ms Failures and errors: Maximum continuous overload (without failure) 0 Ω Max. measuring error at C approx. ± 0. % of the measuring range Temperature error on request Maximum error over the full temperature range on request Overshooting approx. ± 0.0 % of the measuring range Output ripple approx. ± 0.0 % of the measuring range Crosstalk between the channels at DC voltage and AC voltage 0 Hz and 60 Hz - 90 db Maximum temporary deviation on request Short circuit protection electronic Nominal output current max. A System bus: Wire connection () M connectors, B coded, poles, shielded Isolation: Channel - Channel no V LS, V A, system bus 00 V AC each Configurable functions: Measuring range (per channel) 0-0 ma, -0 ma, ±0 ma, 0-0 V, ±0 V Substitute value strategy (per channel) Switch substitute value / hold last value Substitute value (per channel) 0 ma or 0 V / substitute value according to measuring range (Default: 0 ma or 0 V) Online simulation (per channel) Lock/unlock; simulation value: (according to measuring range) Diagnostics (per channel) (per module) Short circuit (voltage) or wire break (current) (actuator supply) Undervoltage (V LS + V A ) Process image: Process data width 8-byte data + status LED indicators: Ch... Ch: output status LED (yellow) Er... Er: output error LED (red) F: Fault status LED (red) V LS + V A : supply status LED (green) SB: system bus status LED (green/red) Indicators non-latching Standards and approvals: r UL 08 Conformity marking General Specifications Dimensions (mm) W x H x L 0 x 7 x Weight approx. 0 g

73 Power Divider V DC 6 outputs (6xM) 6 outputs () 7 V U LS U A intputs () Power divider for supplying SPEEDWAY modules distributed over a large network. Included: WMB module marker card, gray ( pcs) Marker strips ( pcs) M protective caps ( pcs) Description Power Divider Accessories Marker strips, marking pen, spacer See pages module and protective caps IP67 cables and connectors See pages Module supply: Wire connection () M connector, 6 poles* voltage Logic and sensor voltage V LS DC V (- % %) Actuator voltage V A DC V (- % %) current Logic and sensor current I LS typ. ma Actuator current I A typ. ma outputs No. of outputs 6 Wire connection () M connectors, A coded, poles * Current carrying capacity / connector max. 8 A (V LS : A, V A : A) * Current carrying capacity / module max. A (V LS max. 8 A) (V A max. 6 A) * Short circuit protection no Isolation: U LS - U A 00 V AC Standards and approvals: r UL 08 Conformity marking * ) Derating must be observed

74 7 outputs... 6 M A coded : V V LS : V V A : 0 V V LS : 0 V V A : n.c. input 7 M Block diagram of power divider output... 6 M ULS Input 6 M : V V LS : 0 V V LS : n.c. : V V A : 0 V V A 6: n.c. UA General Specifications Dimensions (mm) W x H x L 0 x 7 x Weight approx. 0 g

75 7 WAGO SPEEDWAY 767 System bus / power supply cable + accessories System bus cable, with both ends of cable fitted, B coded M socket, straight, M plug, straight, 0.m M socket, straight, M plug, straight, 0.m M socket, straight, M plug, straight, 0.m M socket, straight, M plug, straight,.0m M socket, straight, M plug, straight, 0.m M socket, straight, M plug, straight,.0m M socket, straight, M plug, straight, 0.0m M socket, straight, M plug, straight, 0.0m M socket, straight, M plug straight, 0.0m M socket, right angle, M plug, right angle, 0.m M socket, right angle, M plug, right angle, 0.m M socket, right angle, M plug, right angle, 0.m M socket, right angle, M plug, right angle,.0m M socket, right angle, M plug, right angle, 0.m M socket, right angle, M plug, right angle,.0m M socket, right angle, M plug, right angle, 0.0m M socket, right angle, M plug, right angle, 0.0m M socket, right angle, M plug, right angle, 0.0m 76-0/ / / / / / / / / / / / / / / / / / SPEEDWAY accessories M system bus terminating plug, B coded, straight USB communication cable / / cable, with both ends of cable fitted, A coded M socket, straight, M plug, straight, 0.m M socket, straight, M plug, straight, 0.m M socket, straight, M plug, straight, 0.m M socket, straight, M plug, straight,.0m M socket, straight, M plug, straight, 0.m M socket, straight, M plug, straight,.0m M socket, straight, M plug, straight, 0.0m M socket, straight, M plug, straight, 0.0m M socket, right angle, M plug, right angle, 0.m M socket, right angle, M plug, right angle, 0.m M socket, right angle, M plug, right angle, 0.m M socket, right angle, M plug, right angle,.0m M socket, right angle, M plug, right angle, 0.m M socket, right angle, M plug, right angle,.0m M socket, right angle, M plug, right angle, 0.0m M socket, right angle, M plug, right angle, 0.0m 76-0/ / / / / / / / / / / / / / / /

76 WAGO SPEEDWAY 767 PROFIBUS cable + accessories 7 PROFIBUS cable, with one end of cable fitted, B coded M socket, straight, one free cable end,.0m M socket, straight, one free cable end,.0m M socket, straight, one free cable end, 0.0m M socket, straight, one free cable end, 0.0m M socket, right angle, one free cable end,.0m M socket, right angle, one free cable end,.0m M socket, right angle, one free cable end, 0.0m M socket, right angle, one free cable end, 0.0m M plug, straight, one free cable end,.0m M plug, straight, one free cable end,.0m M plug, straight, one free cable end, 0.0m M plug, straight, one free cable end, 0.0m M plug, right angle, one free cable end,.0m M plug, right angle, one free cable end,.0m M plug, right angle, one free cable end, 0.0m M plug, right angle, one free cable end, 0.0m 76-0/ / / / / / / / / / / / / / / / PROFIBUS cable, with both ends of cable fitted, B coded M socket, straight, M plug, straight, 0.m M socket, straight, M plug, straight,.0m M socket, straight, M plug, straight, 0.0m M socket, straight, M plug, straight, 0.0m M socket, right angle, M plug, right angle, 0.m M socket, right angle, M plug, right angle,.0m M socket, right angle, M plug, right angle, 0.0m M socket, right angle, M plug, right angle, 0.0m 76-0/ / / / / / / / PROFIBUS accessories M plug, B coded, straight, can be pre-assembled M socket, B coded, straight, can be pre-assembled M terminating plug, B coded, straight, can be pre-assembled 76-90/ / / For additional technical data see: Full Line Catalog W Volume, Accessories Series

77 76 WAGO SPEEDWAY 767 EtherNet, PROFINET cable + accessories EtherNet, PROFINET cable, with one end of cable fitted, D M plug, straight, one free cable end,.0m M plug, straight, one free cable end,.0m M plug, straight, one free cable end, 0.0m M plug, straight, one free cable end, 0.0m M plug, right angle, one free cable end,.0m M plug, right angle, one free cable end,.0m M plug, right angle, one free cable end, 0.0m M plug, right angle, one free cable end, 0.0m 76-0/ / / / / / / / EtherNet, PROFINET cable, with both ends of cable fitted, D M plug, straight, plug, straight, 0.m M plug, straight, plug, straight,.0m M plug, straight, plug, straight, 0.0m M plug, straight, plug, straight, 0.0m M plug, right angle, plug, right angle,.0m M plug, right angle, plug, right angle,.0m M plug, right angle, plug, right angle, 0.0m M plug, right angle, plug, right angle, 0.0m 76-0/ / / / / / / / EtherNet, PROFINET accessories M plug, D coded, straight, can be pre-assembled Adapter M socket, D coded/ RJ- socket Ethernet RJ- Connector IP / /

78 WAGO SPEEDWAY 767 CANopen, DeviceNet cable + accessories 77 CANopen, DeviceNet with one end of cable fitted, A coded M socket, straight, one free cable end,.0m M socket, straight, one free cable end,.0m M socket, straight, one free cable end, 0.0m M socket, straight, one free cable end, 0.0m M socket, right angle, one free cable end,.0m M socket, right angle, one free cable end,.0m M socket, right angle, one free cable end, 0.0m M socket, right angle, one free cable end, 0.0m M plug, straight, one free cable end,.0m M plug, straight, one free cable end,.0m M plug, straight, one free cable end, 0.0m M plug, straight, one free cable end, 0.0m M plug, right angle, one free cable end,.0m M plug, right angle, one free cable end,.0m M plug, right angle, one free cable end, 0.0m M plug, right angle, one free cable end, 0.0m 76-0/ / / / / / / / / / / / / / / / CANopen, DeviceNet with both ends of cable fitted, A coded M socket, straight, M plug, straight,.0m M socket, straight, M plug, straight,.0m M socket, straight, M plug, straight, 0.0m M socket, straight, M plug, straight, 0.0m M socket, right angle, M plug, right angle,.0m M socket, right angle, M plug, right angle,.0m M socket, right angle, M plug, right angle, 0.0m M socket, right angle, M plug, right angle, 0.0m 76-0/ / / / / / / / CANopen, DeviceNet accessories, A coded M plug, straight, can be pre-assembled M socket, straight, can be pre-assembled M terminating plug, straight / / / For additional technical data see: Full Line Catalog W Volume, Accessories Series

79 78 WAGO SPEEDWAY 767 General accessories Marking pen with fiber tip and marker strips Description Marker strips for couplers and I/O modules with 8xM8 connectors Marker strips for I/O modules with xm connectors Marker strips for power distribution modules Marking pen with fiber tip, for permanent marking Spacer module 0 Cable tie mounts 7 mm Description Spacer module 767-0

80 WAGO SPEEDWAY 767 General accessories 79 CR-Adapter CR-Adapter Carrier rail adapters and profile adapters Carrier rail adapter for coupler/progr. coupler Carrier rail adapter for I/O module and power distribution module Profile adapter for coupler/progr. coupler Profile adapter for I/O module and power distribution module on request on request on request on request M8 M M M Description M8 protective cap for unused sockets M protective cap for unused sockets M protective cap for unused plugs M protective cap for unused plugs Connectable cable Ø mm / max.. mm² M plug, can be pre-assembled 6 poles, M plug, straight, soldering technology M plug, right angle, soldering technology / / Connectable cable Ø mm / max.. mm² M socket, can be pre-assembled 6 poles, M socket, straight, soldering technology M socket, right angle, soldering technology / / For additional technical data see: Full Line Catalog W Volume, Accessories Series

81 80 Relay Socket for Industrial Relays, Series 88 Relay socket for industrial relays, and changeover contacts Interface Modules A Note: Inductive loads have to be attenuated by an appropriate protective circuit in order to protect relay coils and contacts. Description Relay Socket for Industrial Relays ( and Changeover Contacts) A Nominal input voltage (V N ) depending on relay; max. AC 0 V Max. switching voltage AC 0 V Max. continuous current x A ( changeover contacts); x 0 A ( changeover contacts) Max. switching power (resistive) AC 000 VA Nominal operating mode continious duty Voltage resistance kv (depending on relay) Nominal voltage acc. to VDE 00 Part /.97, IEC V / kv / Degree of protection IP 0 Ambient operating temperature - C C (depending on relay) Storage temperature -0 C C Dimensions (mm) W x H x L x 8 x 96 Height from upper-edge of DIN rail Wire connection Terminal strips with CAGE CLAMP Super Compact connection Stripped lengths mm / 0.7 in Cross sections 0. mm².... mm² / AWG... 6 Approvals IEC6066 / IEC6066A / DIN VDE00 Degree of pollution Overvoltage category

82 Accessories for Relay Sockets, Series 88 8 Pluggable industrial relays, changeover contacts Pluggable industrial relays, changeover contacts 8 max, max,8 Interface Modules max.... * In order to prevent the gold layerfrom being damaged, these values should not be exceeded. Higher switching power leads to evaporation of the gold layer. The resulting deposits in the enclosure may cause sparkover between the coil and the contact. Description Nominal input voltage (V N ) Nominal input voltage (V N ) Pluggable Industrial Relays DC V 88-0 AC 0 V 88- DC V * 88- AC 0 V * Coil Coil voltage DC V AC 0 V Rated power 0.9 W. VA Coil current 6.9 ma 8. ma Operating range x V x V Holding voltage 0 % of V N 80 % of V N Release voltage 0. x V 0. x V Contacts Contact material AgCe* AgCe + µm Au AgCe Continuous current A * A * Inrush current A / s A / s Switching voltage 0 V AC / 0 V DC 0 V AC / 0 V DC Max. switching power AC / AC 0 VA / 00 VA 0 VA / 00 VA -phase motor load AC 0. kw 0. kw Max. switching current DC A at DC 0 V A at DC 0 V Min. switching load V / 00 ma V / 00 ma Switching frequency under load 0 cycles/min. 0 cycles/min. General Specifications Mechanical life 0 x 0 6 switching operations 0 x 0 6 switching operations Electrical life x 0 switching operations x 0 switching operations Pull-in / drop-out / bounce time typ. ms / ms / ms ms / ms / ms Nominal voltage acc. to VDE 00 Part /.97, IEC V / kv / 0 V / kv / Surge capacity contact-coil (./0 µs) kv kv Dielectric strength contact-coil (AC, min). kv. kv Open circuit kv kv Dielectric strength contact-contact. kv. kv Ambient operating temperature - C C - C C Mounting distance in a row 6 mm 6 mm Weight approx. 7 g approx. 7 g

83 8 Accessories for Relay Sockets, Series 88 Holding bracket Interface Modules Description Holding bracket for industrial relays (height. mm.... mm) Operation status indicator Description Recovery diode DC 6-0 V Operation status indicator DC V Operation status indicator AC/DC 0/0 V (7 V varistor)

84 8 Interface Modules

85 8 Interface Modules Interface Modules Interface module with high density D-sub header for 9" racks S S 6 7 S 6 7 S Description No. of "L" mm Interface Module for 9" Racks Operating voltage AC / DC V Nominal current A Connector contact Copper alloy, gold-plated 0.8 µm Contact resistance 0 m Performance level to DIN 6 00 mating cycles, without corrosion Degree of pollution Nominal voltage acc. to VDE 00 Part /.97, IEC V / 0.8 kv / Touch-proof terminal strip IP0 Touch-proof HD D-sub header IP00 Dimensions (mm) L x W x H incl. mounting feet or mounting carrier 80 x x 7 Wire connection Terminal strips with CAGE CLAMP connection (WAGO Series 79) Cross sections 0.08 mm².... mm² / AWG 8... * * (AWG: THHN, THWN) Stripped lengths... 6 mm / 0, in Mounting direction vertical Pull relief stud bolt UNC -0 Ambient operating temperature -0 C... + C Storage temperature -0 C C Approvals EN 6066

86 Item Number Index 6 Bit) Page Page Page Page Series Series Series Series / Series Series / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / Series Series Series Series / /07-00 Series

87 WAGO Worldwide Companies and Representations Argentina Bruno Schillig S.A. Arenales 00, B60CFD Florida, PBA Phone Fax robertor@schillig.com.ar Australia NHP ELECTRICAL ENGINEERING PRODUCTS PTY LTD -67 River Street Richmond, Victoria, P.O. Box 99 Phone Fax export@wago.com Austria WAGO Kontakttechnik Ges.m.b.H. Laxenburger Straße 0 Wien Phone Fax info.at@wago.com Belgium WAGO Kontakttechnik Excelsiorlaan 90 Zaventem Phone Fax info-be@wago.com Bosnia and Herzegovina WAGO Kontakttechnik GmbH & Co. KG Representative Office Sofia Bulgaria Twardischiki Prohod, ap. 0 Sofia Phone Fax info-bg@wago.com SC_Technik doo Kadić Mahala 7 Bosnia-Herzegovina Phone Fax sc_technik@yahoo.de Brasil WAGO Eletroeletrônicos Ltda Rua Américo Simões 70 Sãu Roque da Chave Itupeva SP Brasil Phone Fax info.br@wago.com Bulgaria WAGO Kontakttechnik GmbH & Co. KG Representative Office Sofia Bulgaria Twardischiki Prohod, ap. 0 Sofia Phone Fax info-bg@wago.com RIM Project Ltd. Probuda - A str., et. 7 Sofia Bulgaria Phone Fax office@rim-bg.com Canada please contact WAGO USA Chile Desimat Chile Av Puerto Vespucio 9670 Pudahuel Santiago Phone Fax ventaschile@desimat.cl China WAGO ELECTRONIC (TIANJIN) Co. LTD No., Quan Hui Road Wuqing Development Area Tianjin 0700 Phone Fax info-cn@wago.com Columbia T.H.L. Ltda. Cra. 9 B # 9- Bogotá Phone Fax ventas-thl@thl-ltda.com Croatia M.B.A. d.o.o. za trgovinu i zastupanje Frana Supila Matulji HR Phone Fax mba@ri.htnet.hr Czech Republic WAGO Elektro spol. sr. o. Rozvodova 6/6 00 Praha - Modřany Phone Fax info.cz@wago.com Denmark WAGO Danmark Filial of WAGO Kontakttechnik GmbH &Co. KG Lejrvej 9 00 Værløse Phone Fax salg.dk@wago.com Ecuador INSETEC CIA. LTDA. El Zurriago 77 y El Vengador P.O. Box Quito Phone Fax g.castro@insetec.com.ec Egypt IBN Engineering Instrumentation & Control 7 a El Shaheed Ahmed Hamdi St. King Faisal, Giza Phone Fax sales@ibnengineering.com Estland Eltarko OÜ Laki Tallinn Phone Fax andres@eltarko.ee Finland WAGO Kontakttechnik GmbH & Co. KG Filial i Finland Vellamonkatu 0 B 000 Helsinki Phone Fax export@wago.com France WAGO CONTACT S.A. Paris Nord 8 Rue des Chardonnerets B.P Tremblay en France ROISSY CDG CEDE Phone Fax info-fr@wago.com Germany WAGO Kontakttechnik GmbH & Co. KG Postfach Minden Hansastrasse 7 Minden Phone Fax info@wago.com Great Britian WAGO Limited Triton Park, Swift Valley Industrial Estate RUGBY Warwickshire, CV SG Phone Fax uksales@wago.com Greece PANAGIOTIS SP. DIMOULAS - BIOMAT Kritis Str Athen Phone Fax export@wago.com Hong Kong National Concord Eng., Ltd. Unit A-B, /F. Southeast Industrial Building 6-69 Castle Peak Road Tsuen Wan, N.T. Phone Fax sales@nce.com.hk Hungary WAGO Hungá ria KFT Ipari Park, Gyár u. 00 Budapest Phone Fax info@wago.hu Iceland S. Gudjonsson ehf. Audbrekku 9-0 Kopavogur Phone Fax export@wago.com India WAGO & CONTROLS (INDIA) LTD. C-7, Sector-8, Phase-III Noida-0 0 Gautam Budh Nagar (U.P) Phone Fax info@wagoindia.com Indonesia please contact WAGO Singapore Iran Patsa Industry No. Bahar St. South Shiraz Ave P.O. Box.: Tehran Phone Fax export@wago.com Ireland Drives & Controls Unit F, Riverview Business Park Nangor Road Dublin Phone Fax wago@drivesandcontrols.ie Israel Comtel Israel Electronic Solutions Ltd. Bet Hapaamon 0 Hataas Street P.O.Box 66 Kefar-Saba Phone Fax sales@comtel.co.il Italy WAGO ELETTRONICA SRL Via Vittoria, /b 0068 San Lazzaro di Savena (BO) Phone Fax info-ita@wago.com Japan WAGO Co. of JAPAN Ltd. Nittetsu ND-Tower Building F Kameido --7 Koto-Ku Tokyo Phone Fax info-jp@wago.com Korea Mahani Electric Co. Ltd Yeoksam-Dong Kangnam-Gu, -080 Seoul, Korea Phone Fax export@wago.com Kosovo please contact WAGO Bulgaria Kuwait Kuwait Controls Company Al Sour Street, Above Lufthansa Airline Safat Kuwait 06 Phone Fax Latvia INSTABALT LATVIA SIA Vestienas iela 6 Rīga, LV-0 Phone Fax info@instabalt.lv

88 Lebanon G.T.C. Antonine Project Block G P.O.BO Antelias Lebanon Phone Fax rgemayel@inco.com.lb Lithuania INSTABALT LIT UAB Savanorių 87 Vilnius, 0 Phone Fax info@instabalt.lt Luxembourg please contact WAGO Belgium Macedonia please contact WAGO Bulgaria Malaysia WAGO Representative Office Malaysia No 806, Block A, Leisure Commerce Square, No 9, Jalan PJS 8/9, 60 Petaling Jaya, Selangor Darul Ehsan, Malaysia Phone Fax kian.guan.tan@wago.com HPH Materials (M) Sdn Bhd No., Jalan Nilam /6 Suban Hi-Tech Industrial Park 0000 Shah Alam Selangor, D.E. Malaysia Phone Fax info@hphmaterials.com Setia Raya Teknik Sdn. Bhd. 0 & Jalan SS/ Subang Jaya, 700 P.J. Selangor D.E. Malaysia Phone Fax sales@setiaraya.com.my Mexico WAGO CORPORATION N0 W99 Freistadt Road Germantown, WI 0 Phone Fax Toll-Free: info.mx@wago.com Netherlands WAGO Nederland van Leeuwenhoekstraat 0-86 CB Harderwijk Phone Fax info-nl@wago.com New Zealand NHP NZ 7 Lockhart Place Mt Wellington New Zealand Phone Fax export@wago.com Norway WAGO Norge NUF Jerikoveien Oslo Phone Fax info.no@wago.com Peru Desimat Peru Av. E. Salazar Barreto No. 80 Surco - Lima Phone Fax export@wago.com Philippines please contact WAGO Singapore Poland WAGO ELWAG sp. z o. o. ul. Piękna 8 a 0-06 Wrocław Phone Fax wago.elwag@wago.com Portugal MORGADO & CA. LDA - SEDE Estrada Exterior da Circunvalação 8/60 Apartado 07 Rio Tinto Phone Fax export@wago.com Romania WAGO Kontakttechnik GmbH & Co. KG WAGO Representative Office Bucharest Str. Nicolae G. Caramfil Nr. 6, Bl. D, Et., Ap. 7, Sect. Bucuresti Romania Phone +0-(0) 8 68 Fax +0-(0) 0 titus.reus@wago.com VDR & Servicii srl Str. Valeriu Branişte, nr. 60, ap., sector Romania Phone +0 07/76 Fax office@componente-automatizari.ro SC Civitronic SRL Str. Prof. Gh. Longinescu Nr. 7 Timisoara, Romania Phone Fax sales@civitronic.ro Russia ООО ВАГО Контакт Рус Россия 706 г. Москва Гостиничный проезд Б Phone Fax info@wago.ru Saudi Arabia Al Quraishi Electrical Services of S. A. P.O. Box 786 Dammam-6 Phone Fax export@wago.com Serbia WAGO Kontakttechnik GmbH & Co. KG Representative Office Sofia Bulgaria 0 Sofia Phone Fax info-bg@wago.com AVALON Partners D.O.O. Str. Nemanjina /II 000 Belgrade / Serbia Phone Fax Tel/Fax: 6 AVALONP office@avalon.co.yu Singapore WAGO Electronic Pte Ltd 0 Upper Aljunied Link, # 0-0 York International, Industrial Building Singapore 6790 Phone Fax info.sing@wago.com Slovakia WAGO Elektrik spol.s r. o Odborárska 80 Bratislava Phone + 80 Fax + 80 export@wago.com South Africa Shorrock Automation (Pty) Ltd Postnet Suite # 9 Private Bag 8,Elardus Park 007 PRETORIA Phone +7 9 Fax +7 sales@shorrock.co.za Spain DICOMAT S.L. Avda. de la Industria, 6 Apartado Correos, Alcobendas (Madrid) Phone Fax info@dicomat.com Sweden WAGO Sverige WAGO Kontakttechnik GmbH Tyskland Filial Box 69, 77 Järfälla Datavägen 9 A, 7 Järfälla Phone Fax info.se@wago.com Switzerland WAGO CONTACT SA Rte. de I Industrie 9 Case Postale 68 6 Domdidier Phone +/ Fax +/ info.switzerland@wago.com Syria Zahabi Co. 8/ Shouhadaa St., P.O. Box 86 Aleppo Phone +96 / 6 Fax export@wago.com Taiwan R.O.C. WAGO Taiwan 8/F., No. 8, Jing-An Road Chung-Ho City, 6 Taipei Hsien. T a i w a n Phone Fax Thailand WAGO Representative Office Thailand th Floor, KS Building /6-8 Rachada-Phisek Road Dingdaeng Bangkok 00 Phone Fax wago@asianet.co.th US Power Distribution Co., Ltd. th Floor K.S. Building /6-8 Rachada Phisek Road Ding Daeng, Bangkok 000 Phone Fax Turkey WAGO Elektronik Sanayi ve Ticaret Ltd. Şti. Barbaros Mahallesi Mimar Sinan Caddesi No Yenisahra - Kadıköy Istanbul Turkey Phone Fax info.tr@wago.com United Arab Emirates (UAE) Binghalib Engineering Ent. Trading Division Al Khabeshi Area P.O. Box 7 Dubai Phone Fax export@wago.com USA WAGO Corporation N0 W99 Freistadt Road Germantown, WI 0 Phone Fax + 6 Toll-Free: -800 DIN Rail (6-7) info.us@wago.com Venezuela PETROBORNAS, C.A. Av. Principal UD 0-Zona Ind. Los Pinos C.C. Los Pinos-Local E 80-Puerto Ordaz-Edo, Bolivar Phone Fax info@petrobornas.net Vietnam please contact WAGO Singapore Version: 0/008 Current addresses at

I/O-SYSTEM/Interface Modules. New Items: Spring 2008 N 3/4

I/O-SYSTEM/Interface Modules. New Items: Spring 2008 N 3/4 /Interface Modules New Items: Spring 008 N / Contents Modular IP0 Series 70, 79 ETHERNET TCP/IP -Port Programmable Fieldbus Controller 0 0 ETHERNET TCP/IP & RS- Programmable Fieldbus Controller 0 0 SERCOS

More information

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555 Industrial Switches Industrial Switch, Base- Industrial Switch, Base- Industrial Switch, Base-, Slots Base-FX Industrial Managed Switch, Base-, Slots Base-FX Industrial Eco Switch, Base- Industrial Eco

More information

Industrial Switches Industrial Switches

Industrial Switches Industrial Switches Industrial Switches Industrial Switches Copper cables Fiber optic cable Ring redundancy Industrial Switches Contents 23 General Product Information 2 Interfaces and Configurations 2 Application and Installation

More information

Programmable Fieldbus Controller XTR. Section 2 Section 3.1 Programmable Fieldbus Controllers. Section 3.3 PFC200

Programmable Fieldbus Controller XTR. Section 2 Section 3.1 Programmable Fieldbus Controllers. Section 3.3 PFC200 Programmable Controllers Section 2 Section 3. Programmable Controllers PERSPECTO Control Panels Merging control and visualization 8.9 cm... 38. cm (3.5 5 ) PFC200 Maximum performance in a minimum space

More information

PLC PFC200 Controller PFC200 CS 2ETH RS

PLC PFC200 Controller PFC200 CS 2ETH RS 0-202 PLC PFC200 Controller PFC200 CS 2ETH RS Marking area Serial interface RJ-4 RJ-4 ACT X2 LNK ETH ACT X LNK X3 RS232/4 U U U4 U3 U2 U STOP RESET 0-202 SYS I/O MS NS U RST SD 0 02 A B 24V 0V + + Status

More information

11 PROFIBUS Fieldbus Connector

11 PROFIBUS Fieldbus Connector 750-960 PROFIBUS Fieldbus Connector 634 54 mm> < < 45mm 5 < 36,7mm < 372 mm < 54 mm < 36 mm / 42 in < 5-6 mm / 022 in < 0 mm / 0394 in The fieldbus connector links a PROFIBUS device

More information

Address. Supply 24 V 0 V Fieldbus connection RJ-45. Fieldbus connection RJ-45. Configuration and programming interface. Pack. System Data.

Address. Supply 24 V 0 V Fieldbus connection RJ-45. Fieldbus connection RJ-45. Configuration and programming interface. Pack. System Data. 20 70-00 PLC PFC00 Controller PFC00 CS 2ETH ECO Address Supply Configuration and programming IP-Adresse ACT X2 LNK ACT X LNK 0V X3 24V 2 3 4 6 7 0: SW/DHCP 2: DHCP RESET STOP RUN SYS RUN I/O MS NS USR

More information

I/O-SYSTEM/Interface Modules. New Items: Spring 2011 N 3/4

I/O-SYSTEM/Interface Modules. New Items: Spring 2011 N 3/4 I/O-SYSTEM/Interface Modules New Items: Spring 20 N 3/4 The new items in this catalog supplement products found in the following main catalogs N 3/4 Volume 4 Interface Modules Volume 3 I/O-SYSTEM Contents

More information

PROFIBUS Fieldbus Connector 634

PROFIBUS Fieldbus Connector 634 750-960 PROFIBUS Fieldbus Connector 634 54 mm> < < 45mm < 36,7mm < 372 mm < 54 mm < 36 mm / 142 in < 5-6 mm / 022 in < 10 mm / 0394 in The fieldbus connector links a PROFIBUS

More information

INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET

INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET 1 Contents ETHERNET Switches ECO and Standard 3 4 SFP Modules Interface for Fiber-Optic 5 ETHERNET Switches Managed 6

More information

AUTOMATION INTERFACE ELECTRONIC. Supplementary Catalog to Full Line Catalogs, Volumes 3/4 Edition 2013/2 3/4

AUTOMATION INTERFACE ELECTRONIC. Supplementary Catalog to Full Line Catalogs, Volumes 3/4 Edition 2013/2 3/4 AUTOMATION Supplementary Catalog to Full Line Catalogs, Volumes 3/4 Edition 203/2 3/4 The new items in this catalog supplement products found in the following main catalogs 3/4 Volume 4 Volume 3 AUTOMATION

More information

Industrial Switches. Industrial switches. Copper cables Fiber optic cables Ring redundancy

Industrial Switches. Industrial switches. Copper cables Fiber optic cables Ring redundancy Industrial Switches Industrial switches Copper cables Fiber optic cables Ring redundancy www.wago.com Volume Section Industrial Switches Industrial Switches Contents Page General Product Information 8

More information

8-Port EN Certified Railway IP67 WATERPROOF MANAGED Gigabit PoE SWITCH. EMG8508 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

8-Port EN Certified Railway IP67 WATERPROOF MANAGED Gigabit PoE SWITCH. EMG8508 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION EMG8508 Series 8-Port EN 50155 Certified Railway IP67 WATERPROOF MANAGED Gigabit PoE SWITCH FEATURE HIGHLIGHTS Up to 8 10/100/1000 BASE-T(X) ports, M12 connector Up to or 8 802.af or 802.at complaint PoE

More information

INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET

INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET 1 Contents ETHERNET Switches ECO, Standard, PoE 3 5 SFP Modules Interface for Fiber-Optic 6 ETHERNET Switches Managed

More information

WAGO MODULAR IP67 I/O SYSTEM

WAGO MODULAR IP67 I/O SYSTEM WAGO MODULAR IP67 I/O SYSTEM modular design high performance data transfer extended temperature range 300 500 400-25 C +60 C 600 IP67 distributed I/O Reduce system cost and boost performance with WAGO

More information

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3 Programmable multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP OPC-Server CODESYS V3 programmable acc.to IEC 61131-3 Ethernet and USB programming interface Protection type IP20 Integrated

More information

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3 Programmable multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP OPC-Server CODESYS V3 programmable acc.to IEC 61131-3 Ethernet and USB programming interface Protection type IP20 Integrated

More information

CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP BL67-PG-EN-V3

CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP BL67-PG-EN-V3 CODESYS V3 programmable acc.to IEC 61131-3 Ethernet and USB programming interface Protection class IP67 Integrated power supply LEDs for display of PLC status, supply voltage, group and bus errors Programmable

More information

I/O-System 750 and 753 Series

I/O-System 750 and 753 Series -System 750 and 753 Series -System 750 and 753 Series Section 5 Section 6 Highly versatile More than 500 modules available Functional safety Ex i -System 750 XTR Series -System SPEEDWAY For demanding applications

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

Ethernet Accessories. For the WAGO-I/O-SYSTEM

Ethernet Accessories. For the WAGO-I/O-SYSTEM Ethernet Accessories For the WAGO-I/O-SYSTEM 852-101 5-Port 100BASE-TX Industrial Switch The 852-101 Industrial Switch is a 5-port 10/100Base-TX Ethernet switch. The switch has a rugged housing, a redundant

More information

Channel Digital Input Module 24 V DC High-side switching

Channel Digital Input Module 24 V DC High-side switching 0-0 -Channel Digital Input Module DC High-side switching 0-0 0-0... 9 0 connection 9 9 0 0 0nF 0nF The digital input module provides channels at a width of just mm (0.in). It receives binary control signals

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Product

More information

Features and Benefits. Certifications

Features and Benefits. Certifications EDS-508A Series 8-port managed Ethernet switches Features and Benefits Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), and STP/RSTP/MSTP for network redundancy TACACS+, SNMPv3, IEEE

More information

IP67 IP20. Controllers Open Flexible Compact SPEEDWAY. Programmable. Fieldbus Couplers. Programmable. Fieldbus Controllers

IP67 IP20. Controllers Open Flexible Compact SPEEDWAY. Programmable. Fieldbus Couplers. Programmable. Fieldbus Controllers WAGO Controllers Controllers Open Flexible Compact WAGO s IEC 61131-3 programmable controllers perform a variety of automation tasks, while providing all the benefits of standard PLC technology (e.g.,

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA

More information

Automation Technology Interface Electronic. Supplementary Catalog to Full Line Catalogs, Volumes 3/4 Edition 2015/2

Automation Technology Interface Electronic. Supplementary Catalog to Full Line Catalogs, Volumes 3/4 Edition 2015/2 Automation Technology Supplementary Catalog to Full Line Catalogs, Volumes 3/4 Edition 2015/2 The new items in this catalog supplement products found in the following main catalogs 3/4 Full Line Catalog,

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

Ver. 01. FnIO S-Series. Integrated Systems for the Speed and Quality

Ver. 01. FnIO S-Series. Integrated Systems for the Speed and Quality Ver. 01 FnIO S-Series Integrated Systems for the Speed and Quality Convenience Economics Stability Considered Design for User. Compact Size : We applied Ultra-small size RTB(Removable Terminal Block) and

More information

Modular IP67 I/O System

Modular IP67 I/O System Modular IP I/O System Where previously discrete wiring was once required, fieldbuses now provide communication between control unit, system and machine. Depending on equipment type, cabinet-free automation

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 50 KB General information

More information

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 75 KB Display with

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 6 DI 24V DC; 4 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Product

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 100 KB General information Firmware

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1217C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT ONBOARD I/O: 10 DI 24V DC; 4 DI RS422/485; 6 DO 24V DC; 0,5A; 4 DO RS422/485; 2 AI 0-10V DC, 2 AQ 0-20MA; POWER SUPPLY: DC

More information

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB Display with display Supply

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Datasheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Engineering

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200F, CPU 1215 FC, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24VDC; 10 DO 24V DC 0.5A; 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes Datasheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY:

More information

8 or 12-Port IEC Certified Industrial Managed Gigabit Switch. EHG9508 EHG9512 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

8 or 12-Port IEC Certified Industrial Managed Gigabit Switch. EHG9508 EHG9512 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION EHG9508 EHG9512 Series 8 or 12-Port IEC61850- Certified Industrial Managed Gigabit Switch FEATURE HIGHLIGHTS IEC61850- Certified Up to 6 or 8 10/100/1000 BASE-T(X) ports and 2 or 1000 BASE-X SFP ports

More information

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

Features and Benefits. Certifications

Features and Benefits. Certifications EDS-505A Series 5-port managed Ethernet switches Features and Benefits Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), and STP/RSTP/MSTP for network redundancy TACACS+, SNMPv3, IEEE

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage. Input current. Encoder supply. Power losses Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200F, CPU 1214 FC, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY 125 KB General information

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

Network Infrastructure Industrial Switches and ETHERNET Components

Network Infrastructure Industrial Switches and ETHERNET Components Network Infrastructure Industrial Switches and ETHERNET Components Content Industrial ECO Switches 4 Industrial Switches 6 Industrial Managed Switches 7 Function Overview of the Industrial Managed Switch

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

Printview: End module for internal data bus extension - Item No.:

Printview: End module for internal data bus extension - Item No.: Printview: End module for internal data bus extension - Item No: 70-627 End module for internal data bus extension Item No: 70-627 End module for internal data bus extension Marking Business data Supplier

More information

Industrial Gigabit Managed Ethernet Switch

Industrial Gigabit Managed Ethernet Switch HMG-828 HMG-828E Industrial Gigabit Managed Ethernet Switch Features High Performance Network Switching Technology Complies with IEEE 802.3, IEEE 802.3u, IEEE 802.3X, IEEE 802.1p, IEEE 802.1q, IEEE 802.1d,

More information

PT-7728 Series. IEC G-port Gigabit modular managed Ethernet switch. Introduction PT-7728

PT-7728 Series. IEC G-port Gigabit modular managed Ethernet switch. Introduction PT-7728 STAT PWR1 PWR2 FAULT MASTER COUPLER LNK/ACT SPEED FDX/HDX MODE COUPLER RING PORT PORT 1 2 3 4 M1 M2 M3 M4 PT-2 PT-2 Series IEC 6150-3 24+4G-port Gigabit modular managed Ethernet switch IEC 6150-3, IEEE

More information

Application RTU560 RJ45 RJ45. Management. Switch RJ45 RJ45. Switch 560NMS34 SDSL. Data Sheet Switch 560NMS34. Port 1. Port 2. Port 3.

Application RTU560 RJ45 RJ45. Management. Switch RJ45 RJ45. Switch 560NMS34 SDSL. Data Sheet Switch 560NMS34. Port 1. Port 2. Port 3. Switch 560NMS34 Application The RTU component 560NMS34 is a managed plug and play Layer2-switch providing four Fast auto-negotiating RJ45-ports with auto MDI/X (Automatic Crossover Detection and Correction)

More information

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 05/2009 MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES.

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory Data sheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40...+70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG40-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC 10 DO 24 V DC 2 AI 0-10V DC, POWER

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

General information Engineering with Programming package. Display with display

General information Engineering with Programming package. Display with display Datasheet SIPLUS S7-1200 CPU 1212C AC/DC/RLY -40... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7212-1BE31-0XB0. COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 8 DI 24V DC 6 DO RELAY 2A 2 AI 0-10V DC, POWER

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet *** SPARE PART*** SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General

More information

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1- KSD-800 Series Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity Installation Guide DOC.110516A -1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

TN-4516A-4GTX Series. EN port managed Ethernet switches. Introduction. Specifications. Industry-specific Ethernet Switches

TN-4516A-4GTX Series. EN port managed Ethernet switches. Introduction. Specifications. Industry-specific Ethernet Switches TN-4516A-4GTX Series EN 50155 16-port managed Ethernet switches Isolated power inputs with universal 24 to 110 VDC power supply Essential compliance with EN 50155* -40 to 75 C operating temperature range

More information

NEW. Phone: Fax: Web: -

NEW. Phone: Fax: Web:  - NEW 8-port unmanaged switch in IP67 Just 54 mm wide One LED per port for link / speed / data Fault relay: 1 x M12 A-coded, 5-pole (24 V DC / 1 A) 8 x M12 D-coded, 4-pole Redundant voltage supply 2 x M12

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current Datasheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG31-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER

More information

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation

More information

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety iologik 4000 Series Modular remote I/O I/O expansion without a backplane Supports SNMPv1/v2c Active communications with MX-AOPC UA Server Easy configuration with Modular ioadmin utility Friendly configuration

More information

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI On-machine Compact fieldbus I/O block EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet Switch 10 Mbps / 100 Mbps Two 4-pole M12, D-coded, connectors for fieldbus connection 2 rotary switches

More information

iologik E1200H Series

iologik E1200H Series iologik E1200H Series Ethernet remote I/O for offshore wind power applications Features and Benefits User-definable Modbus TCP Slave addressing 2-port Ethernet switch for daisy-chain topologies Active

More information

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter Industrial 10/100/BASE-T to 100/BASE-X SFP Media Converter Physical Port 1-port 10/100/BASE-T RJ45 with auto MDI / MDI-X function 1 SFP interface, 100/BASE-X dual mode (auto detection) Layer 2 Features

More information

WaveLine managed switches with IOs

WaveLine managed switches with IOs WaveLine managed switches with IOs Our WaveLine switches come optionally with two digital IOs (input and output). After the IOs are configured, network parameters can be monitored with the managed switch.

More information

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty ioogik E4200 Modular Active Ethernet I/O adaptor Supports up to 16 I/O modules Dual Ethernet ANs and one RS-232 port Front-end intelligence that supports 80 Click&Go rules Unicode Active Messaging with

More information

HARTING Ha-VIS mcon 3000 Next Generation Full managed Ethernet PROFINET Switch

HARTING Ha-VIS mcon 3000 Next Generation Full managed Ethernet PROFINET Switch HARTING Ha-VIS mcon 3000 Next Generation Full managed Ethernet PROFINET Switch Datenblatt / Datasheet Zubehör / Accessoires 1 Ha-VIS mcon 3000 Next Generation Introduction and features Ha-VIS mcon 3000

More information

4 or 8-Port Industrial Managed Gigabit PoE Switch. EHG7504 EHG7508 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

4 or 8-Port Industrial Managed Gigabit PoE Switch. EHG7504 EHG7508 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION EHG7504 EHG7508 Series 4 or 8-Port Industrial Managed Gigabit PoE Switch FEATURE HIGHLIGHTS Up to 8 10/100/1000 BASE-T(X) RJ45 ports or 1000 BASE-X SFP slots. Up to 8 802.af/ 802.at Power over Ethernet

More information

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual 10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1

More information

1Industrial Ethernet Switch

1Industrial Ethernet Switch Ethernet Switch DIN-Rail Managed Fast PoE Ethernet Switch v2.0a / Feb, 2013 Features 10-port managed PoE Ethernet switch with 8x10/100Base- T(X) P.S.E. and 2xGigabit combo ports, SFP socket, 24V power

More information

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters Ethernet Switches and Media Converters SE2 Series DIN Rail mounted switches Features Broadcast storm protection Wide temp range option Optional panel mounting accessory 12, 24, 48 VDC & 18-30 VAC redundant

More information

IEC / EN G-port Gigabit modular managed rackmount Ethernet switches STAT PWR1 PWR2 FAULT MASTER COUPLER LNK/ACT SPEED FDX/HDX

IEC / EN G-port Gigabit modular managed rackmount Ethernet switches STAT PWR1 PWR2 FAULT MASTER COUPLER LNK/ACT SPEED FDX/HDX STAT PWR1 PWR2 FAULT MASTER COUPLER LNK/ACT SPEED FDX/HDX MODE COUPLER RING PORT PORT M1 M2 M3 M4 M1 M2 M3 M4 PT-7728 PT-7728 Series IEC 61850-3 / EN50155 24+4G-port Gigabit modular managed rackmount Ethernet

More information

EN port managed Ethernet switch with 8x10/100Base-T(X) and 2xGigabit combo ports, SFP socket

EN port managed Ethernet switch with 8x10/100Base-T(X) and 2xGigabit combo ports, SFP socket EN50155 10-port managed Ethernet switch with 8x10/100Base-T(X) and 2xGigabit combo ports, SFP socket Features Leading EN50155-compliant Ethernet switch for rolling stock application World s fastest Redundant

More information

Industrial Managed Ethernet Switch

Industrial Managed Ethernet Switch HME-823 HME-823E Industrial Managed Ethernet Switch Features High Performance Network Switching Technology Complies with IEEE 802.3, IEEE 802.3u, IEEE 802.3X, IEEE 802.1p, IEEE 802.1q, IEEE 802.1d, IEEE

More information

ies8g COMMUNICATIONS Features Intelligent 8 Port Managed Gigabit Ethernet Switch Tel: Fax:

ies8g COMMUNICATIONS Features Intelligent 8 Port Managed Gigabit Ethernet Switch Tel: Fax: ies8g www.is5com.com Intelligent 8 Port Managed Gigabit Switch Features Rapid Ring Recovery: iring (recovery time < 30ms up to 250 ethernet switches) ies8g C O M TM P2 P1 ibridge is a unique feature that

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

Modular IP67 I/O System

Modular IP67 I/O System Modular IP I/O System Where previously discrete wiring was once required, fieldbuses now provide communication between control unit, system and machine. Depending on equipment type, cabinet-free automation

More information

JUMO mtron T Measuring, Control, and Automation System

JUMO mtron T Measuring, Control, and Automation System Data Sheet 705001 Page 1/10 JUMO mtron T Measuring, Control, and Automation System Central processing unit Brief description The central processing unit is the heart of the system. It contains the process

More information

Features and Benefits. Certifications

Features and Benefits. Certifications iopac 8600 Series Rugged modular programmable controllers Features and Benefits Modular CPU/power/backplane design that supports 85M/86M modules Tag-centric design with ready-to-run services Supports C/C++

More information

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description SB2WEB BACnet Controller Benefits Configurable by software. Building automation functions and energy data logging are configurable by software. Spread sheets compatible. All data exports are compatible

More information

1Industrial Ethernet Switch

1Industrial Ethernet Switch Ethernet Switch DIN-Rail Managed Ethernet Switch v2.0a / Dec, 2011 Features 18-port managed Ethernet switch with 16x10/100Base-T(X) and 2xGigabit combo ports, SFP socket 1 Ethernet Switch Fastest Redundant

More information

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System Features 10/100Mbps Ethernet full duplex Auto Negotiation Support C++/C Modbus/TCP drivers and OPC server Support configuration via built-in Web browsing, (HTML), Device Finder and I/O configuration utilities

More information

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type designation Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100

More information

Programmable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2

Programmable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2 Type designation Ident no. 1545069 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

Controllers Open Flexible Compact

Controllers Open Flexible Compact Controllers Open Flexible Compact CONTROLLERS Open Flexible Compact Based on CODESYS 3 Based on CODESYS 2.3 WAGO offers programmable controllers in a wide variety of performance classes for controlling

More information

Modular IP67 I/O-SYSTEM

Modular IP67 I/O-SYSTEM Modular IP I/O-SYSTEM Machine-Mount, Cabinet-Free Automation Solution Where previously discrete wiring was once required, fieldbuses now provide communication between the control and field levels. Depending

More information

MGate 5102-PBM-PN Series

MGate 5102-PBM-PN Series MGate 5102-PBM-PN Series 1-port PROFIBUS-to-PROFINET gateways Features and Benefits Protocol conversion between PROFIBUS and PROFINET Supports PROFINET IO device Supports PROFIBUS DP V1 master Automatic

More information

FL SWITCH Factoryline 5- and 8-port managed switches with optional fiber optic ports and wide temperature ratings. Data sheet.

FL SWITCH Factoryline 5- and 8-port managed switches with optional fiber optic ports and wide temperature ratings. Data sheet. Factoryline 5- and 8-port managed switches with optional fiber optic ports and wide temperature ratings Data sheet 3037_en_B PHOENIX CONTACT 2012-06-20 1 Description The FL SWITCH 300 managed switches

More information