INSTALLATION GUIDE. Remote RMM-700 Intelligent Site Management Device. Installation Guide WESTELL.COM

Size: px
Start display at page:

Download "INSTALLATION GUIDE. Remote RMM-700 Intelligent Site Management Device. Installation Guide WESTELL.COM"

Transcription

1 Remote RMM-700 Intelligent Site Management Device Guide INSTALLATION GUIDE Westell Technologies April 2015 Part # Rev. A

2 Copyright 2015 by Westell, Inc. All Rights Reserved. Westell, Kentrox, and Optima Management System are registered trademarks of Westell. All other names are trademarks of their respective owners. Information is correct at time of publication and is subject to change without notice. Contact Westell in Aurora, Illinois, to verify current product information. Westell, Inc. is an Equal Opportunity/Affirmative Action employer. Westell, Inc. 750 North Commons Drive Aurora, Illinois USA Toll Free: (800) International: +1 (630) Fax: +1 (630) Page 2

3 Product Components Product Components Front Panel Components - Remote RMM Ethernet Ports 2 Serial Ports Serial port 1 operates only in RS232 mode. Serial port 2 operates in RS485 mode or RS422 mode. Tx/Rx SMA Female Cellular/ PCS Antenna Diversity SMA Female Cellular/PCS Antenna Chassis Ground Pinouts - see page 4 SiteBus Connection Analog Input Relay 12 Discrete Ports Unit Status LEDs DC Power Inputs A & B Page 3 LED Status ALM DC FLT LED Description Summary alarm LED: Illuminates when any point is in alarm state DC input power LED: Illuminated when valid DC input power is applied to the unit Hardware Failure LED: -- Illuminates when processor is not functioning, or when RMM-700 has been powered up and bootloader is loading -- Blinks when bootloader has loaded and kernel is loading -- Goes out when RMM-700 bootup is completed

4 Pinouts Pinouts SiteBus Port 8 1 Pin Signal 1 No connection No connection 4 data 6 ground 6 No connection 7 No connection 8 No connection Asynchronous Serial Ports RS232 Mode Pin Signal Direction 1 RTS Output 2 DTR Output 3 TXD Output 4 Ground 5 Ground 6 RXD Input 7 DSR Input 8 CTS Input 8 1 RS422 Mode Full Duplex Pin Signal Direction 1 Reserved* 2 TXb Output 3 TXa Output 4 Ground 5 Ground 6 RXa Input 7 RXb Input 8 Reserved* RS485 Mode Half Duplex Pin Signal Direction 1 Reserved* 2 TXRXb Bidirectional 3 TXRXa Bidirectional 4 Ground 5 Ground 6 Hi-Z 7 Hi-Z 8 Reserved* * On serial port 2, these pins are reserved for diagnostic access. Contact Westell Customer Assistance for more information. Ethernet Switch Ports Illuminates when a link is established. 8 1 Blinks when data transfer is active. Pin Signal Direction 1 RX+ Input 2 RX- Input 3 TX+ Output 4 Termination 5 Termination 6 TX- Output 7 Termination Input 8 Termination Input Page 4

5 Cautions and Warnings Cautions and Warnings Grounding and Electrical Safety CAUTION: Westell s Kentrox equipment and peripherals contain electrostatic sensitive components. Proper handling, shipping, and storage precautions must be exercised. CAUTION: During installation, read and observe all additional Cautions and Warnings shown in Step 1: Install SIM Chip and Wireless Phone Module Hardware in Remote RMM-700, Step 4: Attach Chassis Ground, and Step 5: Connect DC Power Input. CAUTION: For Westell s Kentrox equipment to operate safely and correctly, there must be a safety ground strap between the equipment ground bolts and the office ground. Environment CAUTION: In the event that Remote RMM-700 has been subjected to adverse environmental conditions, a service inspection of Remote RMM-700 should be made to ensure safe operation. Restricted Access Locations FCC CAUTION: The Remote RMM-700 is for use in restricted access locations only. Page 5 The Federal Communications Commission has set limits for emitted radio interference, and Remote RMM-700 is constructed with this electromagnetic interference (EMI) limitation in mind. Remote RMM-700 is classified under FCC regulations as a Class A device, that is, a device for use in commercial environments and not in residential areas. This device has been tested and shown to comply with the following FCC rule: Part 15 Subpart J. Operation of this equipment in a residential area may cause interference to radio and TV reception, requiring the user to take whatever steps are necessary to correct the interference.

6 Cautions and Warnings Information is available from the FCC describing possible corrective actions. To maintain low EMI levels, we suggest that you use only metal connectors and shielded cable grounded to the frame. Specifications are subject to change without notice. Clock Battery CAUTION: The Real Time Clock battery is intended to last for the life of the product, and should not require replacement under normal operation. If for any reason the battery does require replacement, the unit should be returned for service at Kentrox. Contact Customer Assistance if this need arises. Page 6

7 Customer Assistance Customer Assistance All customers, partners, and resellers who have a valid Westell Support and Services Agreement have complete access to the technical support resources. Pre-sales Support Westell offers pre-sales technical support from 9 a.m. to 5 p.m. Eastern time, Monday - Friday. Representatives are standing by to assist with customer account information and product ordering and answer questions regarding Westell products and solutions. Phone number: , option 1 Before you call or Before you contact Westell for assistance, please have the following information available: The versions of hardware and software you are currently running The error number and exact wording of any messages that appeared on your screen What happened and what you were doing when the problem occurred How you tried to solve the problem Technical Support support is available. You may send at any time during the day; however, responses will be provided only during normal business hours, in accordance with your Service and Support Agreement. To contact Technical Support, send to: support@westell.com Telephone Technical Support Available to qualified Westell customers or partners who have not been able to resolve their technical issue by using our online services. To qualify for support, you must have a valid Support and Services Agreement. Phone number: , option 2 Normal Business Hours: 8 a.m. to 6 p.m. Eastern time After-Hours Support: Available to qualified customers who are experiencing serviceaffecting outages that cannot wait until the next business day. To qualify for after-hours support, you must have a valid 24x7 Support and Services Agreement. Call the number above, option 2, and follow the prompts for after-hours service. Page 7

8 Customer Assistance Product Documentation You can also access and view the most current versions of Kentrox product documentation on our web site at: Page 8

9 Required Tools and Materials Required Tools and Materials Tools Materials #2 Phillips screwdriver Small flathead screwdriver (Phoenix 3 mm, recommended) Crimping tool Wire cutter Wire stripper ESD wrist strap PC or laptop with Kentrox Redirect software installed Screws and lock washers sized to fit your equipment rack Wire for input power connections (16 AWG solid or stranded insulated) Wire for ground connection (14 AWG, copper conductor) Ground lugs for rack or other earth ground Antioxidant Various required rack cables and cable assemblies. For assistance in acquiring cables, contact Westell Customer Assistance. Page 9

10 Step 1: Install SIM Chip and Wireless Phone Module Hardware in Remote RMM-700 CAUTION: Kentrox equipment and peripherals contain electrostatic sensitive components. Proper handling precautions must be exercised. If your Remote RMM-700 includes the wireless phone module, follow these steps to install the necessary hardware: Note: of a SIM Chip and/or wireless phone module is not necessary in all applications. If your Remote RMM-700 comes with the phone module and SIM chip installed, proceed to Step 2: Install Mounting Flanges. 1. Affix the FCC sticker (included with the phone module) to the product label on Remote RMM Using a screwdriver, remove the top/back cover from Remote RMM-700 by removing the screws from both sides of the top and the center of the back of the unit. (See Figure 1-1 on page 10). Slide the top cover back and remove it from the unit. Screws Figure 1-1 The installer removes the screw from the back side of Remote RMM-700. Page 10

11 3. The SIM chip slides into a card holder on the back edge of the circuit board, shown in Figure 1-2. Follow the steps shown in Figure 1-3 to install the SIM.. SIM Chip Figure 1-2 The SIM Chip is shown partially inserted into its card holder. 1. Slide metal lock back (toward hinge) 2. Open card holder 3. Insert SIM 4. Press card holder into place against the circuit board and slide metal lock forward to lock holder into place Figure 1-3 steps for the SIM. 4. To install the Phone Module, start by inserting the two antenna terminals into the openings in the front of the unit. Turn both wires so they are oriented to connect Page 11

12 to the module via the standoff posts with a minimum of twisting. Secure each terminal with a lock washer and a nut as shown in Figure 1-4. Figure 1-4 The installer secures an antenna terminal in the front of Remote RMM-700 with a lock washer and nut. 5. Connect the module lead labeled Main to the opening marked on the Remote cover as TX/RX, and connect the lead labeled Aux to the opening labeled Diversity. 6. As shown in Figure 1-5, insert the end of the phone module opposite the leads into the module socket on the motherboard. Next, press down the other end of the phone module until it locks in place. Figure 1-5 The installer inserts the non-lead end of the phone module into its socket, above left, and then snaps the module into place, above right. Page 12

13 7. Run the lead wires through the clips on top of the two white plastic standoffs near the module as shown in Figure 1-6. In the completed installation, the wires should be clear of the circuit board. Standoffs Figure 1-6 Run the lead wires through the tops of the standoffs to keep them clear of the circuit board. 8. Reinstall the Remote RMM-700 top cover, and reinsert and tighten the screws in the top and back panels. Step 2: Install Mounting Flanges The Remote RMM-700 is designed for installation in a 19-inch or 23-inch equipment rack using mounting flanges which attach to each side of the device. The Remote RMM- 700 also can be mounted onto a wall using the same mounting flanges. Page 13

14 Figure 1-7 Mounting flanges oriented to install Remote RMM-700 in a 19-inch rack. To install Remote RMM-700 flush with the rack face, use screws to attach the mounting flanges to the three openings near the front of the device as shown in Figure 1-7. Orient the short and long sides of the mounting brackets as needed to fit the rack width The installer can place the Remote RMM-700 to protrude from the front of the rack or to be recessed behind the front by changing the flange orientation and/or by attaching the flanges to the openings at the rear of each side. To attach Remote RMM-700 to a wall, attach the flanges to the openings at the rear of each side, oriented so the other side of the flanges are flush with the rear of the device. The Remote RMM-700 can then be attached to the wall with screws turned through openings on the flanges. Step 3: Attach Remote RMM-700 to Rack Install mounting screws and lock washers into the mounting holes and tighten firmly to the face of the rack. No space is required between Remote RMM-700 and any component above or below Remote RMM-700. Step 4: Attach Chassis Ground Connect the chassis ground on the front face of Remote RMM-700 to a suitable ground such as the frame ground of a rack system or a reliable earth ground. CAUTION: The chassis ground must be connected to the same earthing electrode conductor as the DC supply system or to a bonding jumper (from an earthing terminal or bus) connected to the earthing electrode of the DC supply system. The chassis must be located in the same immediate area (such as adjacent cabinets) as other equipment connected to the same DC power system Page 14

15 and earthing electrode conductor. The DC system cannot be earthed elsewhere. The DC power source must be located in the same premises as the chassis. No switching or disconnecting devices can occur between the earthed conductor of the DC source and the earthing electrode conductor. Notes: For ground connection, use 14AWG or larger conductor. Apply an appropriate antioxidant to the bare conductors before crimping the connector to the connector mating surface. Step 5: Connect DC Power Input WARNING: Turn off the power feed before connecting wires. Connect the input power feed to the power supply connector. Be careful to observe polarity. Unscrew these two screws to remove the power connector, if necessary. Caution: A readily accessible disconnect device (suitably approved and rated) must be incorporated in the field wiring. To connect wires: 1. Turn off power feed. 2. Strip ends of wire 5/16 in. (7 mm). 3. (optional) Using a small flathead screwdriver, loosen screws on sides of power connector on the bottom right front of Remote RMM (optional) Remove power connector. Page Insert wire into connector and tighten screws.

16 Notes: Connect power connector to a reliably grounded -48 VDC safety extra-low voltage (SELV) source. Use 16 AWG copper conductors. Typical circuit fuse: 3 A Step 6: Connect the Port Cables Connect all port cables per your application. For assistance in acquiring cables, contact Westell Customer Assistance. Note: When connecting the communication ports to an external device that does not share the same earth and signal grounding system, an isolation device should be used. Connecting to an Asynchronous Serial Port Asynchronous serial ports allow terminal devices with asynchronous serial ports (such as PCs, NEs, and asynchronous modems) to connect to Remote RMM-700. Connect one of the asynchronous serial ports (labeled RS 232 and RS 485/422 on the front panel) to an external device, such as a modem: 8-pin modular plug to 8-pin modular plug rollover DTE ro DTE null RS232 cable Male DB-25 to 8-pin modular plug DTE to DCE straight cable Female DB-25 to 8-pin modular plug DTE to DTE null RS232 cable Female DB-9 to 8-pin modular plug DTE to DTE null RS232 cable Note: Use shielded cable to ensure compliance with applicable emission standards. Connecting to a Switched Ethernet Port The switched Ethernet ports allow you to connect Ethernet-capable devices to Remote RMM-700 and allow you to connect Remote RMM-700 to a LAN. Use an 8-pin modular plug to 8-pin modular plug straight 100BaseT cable to connect one of the switched Ethernet ports (labeled ETHERNET on the Remote RMM-700 front panel) to an Ethernet device on your network. Step 7: Configure an IP Address Configuring the IP address allows Remote RMM-700 to be accessed remotely. Page 16

17 To configure the IP address: 1. Install Westell s Kentrox Redirect software on your laptop or PC. When the installation is complete, Kentrox Redirect and Kentrox Kickstart icons appear on your desktop. 2. Use a standard CAT5 Ethernet cable to connect the PC or laptop to an Ethernet port on Remote RMM Launch Kentrox Kickstart. Kickstart discovers the Remote RMM-700 device, as shown in Figure 1-8. Note: If the Remote RMM-700 device is not discovered within one minute, select Help > About in Kentrox Kickstart, then click the Network Troubleshooting Guide link for instructions. Figure 1-8 The Kentrox Kickstart GUI shows that it has discovered a Remote, in this case under the hostname rmc27. Important: If a security alert appears advising that the server s host key is not cached in the registry, click the yes button to add the key to the cache. See Figure 1-9. Page 17

18 Figure 1-9 Host key security alert. 4. Click SSH Terminal (or select Tools > SSH Terminal). An SSH window opens, displaying the login prompt. 5. At the login prompt, enter admin. This is the default login. 6. At the Remote RMM-700 password prompt, enter password. This is the default password. 7. At the command prompt, enter config interface bridge switch ip address, followed by the IP address and subnet mask. For example: config interface bridge switch ip address At the command prompt, enter config ip route default and the default gateway address. For example: config ip route default Page 18

19 Technical Specifications Technical Specifications Specification Weight Size Mounting Operating Environment (Ambient) Power Fuse Ratings Input/Output Ports Description 3.15 lb (1.42 kg) Height: 1.6 in. (4.1 cm) Width: 11.8 in. (30 cm) Depth: 8.6 in. (21.8 cm) Mounts in a standard 19-in. or 23-in. rack. Also wall mounts. Temperature: -40 to 65 C Relative humidity: 0% to 95% (non-condensing) Dual input (A/B feed): 5 watts minimum, 12 watts maximum Input voltage range: +/- 20 to 60VDC Voltage applications: +24VDC and -48VDC 0.5 A at 60 VDC 2 10/100 BaseT Ethernet switch ports 1 RS232 asynchronous serial port 1 RS485/RS422 asynchronous serial port 1 SiteBus, One Wire Interface Up to 12 One Wire sensors 12 Digital inputs, pre-wetted with common ground 1 Analog input: Voltage mode: Range: +/- 0 to 10 VDC Input impedance: greater than or equal to 400K Ohm Current mode: Range: 4 to 20 ma DC Input impedance: 100 Ohm Accuracy: +/-2% of full-scale 1 Relay output: Contact rating: 30 VDC at 2 A resistive Contact type: Form C Page 19

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide Remote RMM-1400 Intelligent Remote Site Management Device Guide INSTALLATION GUIDE Westell Technologies Part # 030-300645 Rev. A Copyright 2015 by Westell Technologies. All Rights Reserved. Westell, Kentrox

More information

INSTALLATION GUIDE. Remote RMM-800 Intelligent Site Management Device. Installation Guide WESTELL.COM

INSTALLATION GUIDE. Remote RMM-800 Intelligent Site Management Device. Installation Guide WESTELL.COM Remote RMM-800 Intelligent Site Management Device Guide INSTALLATION GUIDE Westell Technologies July 2016 Part # 030-300731 Rev. C Copyright 2016 by Westell, Inc. All Rights Reserved. Westell, Kentrox,

More information

RMB Peripheral Units Installation Guide

RMB Peripheral Units Installation Guide RMB Peripheral Units Installation Guide Part Number 65-000101 2011 by Kentrox, Inc. All rights reserved. Copyright 2011 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication

More information

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A RMB-3 Peripheral Unit Installation Guide INSTALLATION GUIDE Westell Technologies Part # 030-300812 Rev. A Copyright 2017 by Westell Technologies. All Rights Reserved. The material discussed in this publication

More information

AI130 AIswitch Series 130 Chassis Installation Guide

AI130 AIswitch Series 130 Chassis Installation Guide AI130 AIswitch Series 130 Chassis Installation Guide Part Number QR-130 Rev 3 2007 by Kentrox, Inc. All rights reserved. Copyright 2007 by Kentrox, Inc. All Rights Reserved. The material discussed in this

More information

AI port High Speed Asynchronous Line Card Installation Guide

AI port High Speed Asynchronous Line Card Installation Guide AI232 32-port High Speed Asynchronous Line Card Installation Guide Part Number QR-232 Rev 3 2008 by Kentrox, Inc. All rights reserved. Copyright 2008 by Kentrox, Inc. All Rights Reserved. The material

More information

AI180I AIswitch Series 180 Integrated Chassis Installation Guide

AI180I AIswitch Series 180 Integrated Chassis Installation Guide AI180I AIswitch Series 180 Integrated Chassis Installation Guide Part Number QR-180I Rev 5 2008 by Kentrox, Inc. All rights reserved. Copyright 2008 by Kentrox, Inc. All Rights Reserved. The material discussed

More information

Remote RMX-3200 Intelligent Site Management Device. Installation Guide

Remote RMX-3200 Intelligent Site Management Device. Installation Guide Remote RMX-3200 Intelligent Site Management Device Installation Guide INSTALLATION GUIDE Westell Technologies Part # 030-300637 Rev. A Copyright 2015 by Westell Technologies. All Rights Reserved. Westell,

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0

More information

Installing the Cisco AS5400XM Universal Gateway

Installing the Cisco AS5400XM Universal Gateway CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions 3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These

More information

Enclosure TS-530 User Manual

Enclosure TS-530 User Manual Enclosure TS-530 User Manual 16525 East Laser Drive Fountain Hills, AZ 85268 TEL 480.837.5200 FAX 480.837.5300 info@embeddedx86.com http://www.embeddedx86.com/ Technologic Systems, Inc. COPYRIGHT 1998-200

More information

An ISO-9001 Certified Company

An ISO-9001 Certified Company USER MANUAL MODEL 1002 and 1002S Asynchronous 2-Wire / Coax Short Range Modem An ISO-9001 Certified Company Part #07M1002-C Doc. #050011UC Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT

More information

Installing the Cisco 2524 and Cisco 2525 Routers

Installing the Cisco 2524 and Cisco 2525 Routers CHAPTER 3 Installing the Cisco 2524 and Cisco 2525 Routers This chapter guides you through the installation of the Cisco 2524 and Cisco 2525 routers and includes the following sections: Required Tools

More information

Perle SMI Media Converter Installation Guide

Perle SMI Media Converter Installation Guide Perle SMI Media Converter Installation Guide P/N 5500316-14 Overview This guide contains instructions necessary for the installation and operation of the Perle SMI Media Converter. This media converter

More information

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

WIRESPEED ADSL MODEM (MODEL 2000) User Guide WIRESPEED ADSL MODEM (MODEL 2000) User Guide Copyright 2001 Westell, Inc. All rights reserved. 030-300187 Rev. A Printed in the United States of America December 2001 CONTENTS 1. PRODUCT DESCRIPTION...

More information

RS-232/RS-422 Optical Isolator

RS-232/RS-422 Optical Isolator MAY 1998 IC457A-F IC457A-M RS-232/RS-422 Optical Isolator CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules This document provides the installation and removal instructions for the AC and DC input power supply and fan modules

More information

Storage/Control I/O Module

Storage/Control I/O Module CHAPTER 4 The performs two functions: to connect outside interfaces to the system controller and to house the hard disk drive. It plugs into the back of the VCO/4K system and provides the I/O interfaces

More information

Installation and Configuration Guide

Installation and Configuration Guide Installation and Configuration Guide Trademark Notices Comtrol, NS-Link, and DeviceMaster are trademarks of Comtrol Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation.

More information

TCNM-ACBB1 Installation Manual

TCNM-ACBB1 Installation Manual The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is

More information

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis 5910 High Density Lifeline POTS Splitter Installation Instructions Document Number 5910-A2-GZ40-00 May 2005 About the 5910 POTS Splitter The 5910 is a double-density POTS splitter that separates the (Digital

More information

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Hypercable injecteur HPOE -  Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail : Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15

More information

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions

More information

Miniature Asynchronous 4-Wire High Speed Modems

Miniature Asynchronous 4-Wire High Speed Modems ME1862A-F ME1863A-F JULY 2003 ME1862A-M ME1863A-M Miniature Asynchronous 4-Wire High Speed Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)

More information

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1225 ParaLink TM Parallel Short Range Modem C E R T I F I E D An ISO-9001 Certified Company Part #07M1225-B Doc. #104011UB Revised 9/12/97 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT

More information

DATA CONNECT ENTERPRISE

DATA CONNECT ENTERPRISE DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7

More information

Channel Switch CS. General Operating, Maintenance and Installation Manual

Channel Switch CS. General Operating, Maintenance and Installation Manual Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September

More information

16-Port Chassis Media Converter System Manual

16-Port Chassis Media Converter System Manual 16-Port Chassis Media Converter System Manual 17732-B 16-Port Media Converter (ST Connectors, Shown) INTRODUCTION This system manual describes the ADC 16-Port Media Converter with SC and ST connectors,

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis The Transition Networks CPSMC0200-2x0 series dual-slot PointSystem chassis is designed for installation of one or two selectable Transition Networks

More information

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

PIX 515/515E. PIX 515/515E Product Overview CHAPTER CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses

More information

TN-5308 Quick Installation Guide

TN-5308 Quick Installation Guide TN-5308 Quick Installation Guide Moxa ToughNet Switch Edition 6.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

Cardax FT Controller 3000

Cardax FT Controller 3000 Installation Note Cardax FT Controller 000 CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any

More information

SoundwebTM. Installation Guide

SoundwebTM. Installation Guide 105 SoundwebTM Soundweb TM 9000 Installation Guide Soundweb TM Regulatory Information An example of this equipment has been tested and found to comply with the following European and international Standards

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date: EasySync Ltd ES-R-2x01-M RS232 to RS422 / RS485 Converter User Guide Document Reference No.: ES_000011 Issue Date: 2009-04-10 The ES-R-2001-M and ES-R-2101-M provide a simple method of converting RS232

More information

Installing the Cisco Unified Videoconferencing 3545 MCU

Installing the Cisco Unified Videoconferencing 3545 MCU CHAPTER 2 Installing the Cisco Unified Videoconferencing 3545 MCU The Cisco Unified Videoconferencing 3545 MCU works together with a Cisco Unified Videoconferencing 3545 EMP Enhanced Media Processor (EMP)

More information

Perle SMI Media Converter Installation Guide

Perle SMI Media Converter Installation Guide Perle SMI Media Converter Installation Guide P/N 5500316-10 Introduction Perle SMI Media Converters provide seamless high-speed managed integration of Ethernet to Fiber networks. Overview This guide contains

More information

Preparing to Install the Cisco AS5350XM Universal Gateway

Preparing to Install the Cisco AS5350XM Universal Gateway CHAPTER 2 Preparing to Install the Cisco AS5350XM Universal Gateway This chapter describes the tasks you must perform before you begin to install the Cisco AS5350XM universal gateway and includes the following

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function Appendix A Specifications This appendix lists the specifications for the BANDIT family of products. Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200

More information

Follow the procedure below for unpacking the carton in which the device is shipped. DW-GTW-AC-E1060 Four anti-slide bumpers for desktop installation

Follow the procedure below for unpacking the carton in which the device is shipped. DW-GTW-AC-E1060 Four anti-slide bumpers for desktop installation 1 Introduction This document provides a hardware description of the DW-GTW-AC-E1060 (hereafter referred to as device) and step-by-step procedures for mounting and cabling the device. The device supports

More information

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R LOOP TELECOMMUNICATION INTERNATIONAL, INC. 8F, NO. 8, HSIN ANN

More information

Site Preparation CHAPTER

Site Preparation CHAPTER CHAPTER 3 Site Preparation This chapter describes the steps to take and the considerations you should keep in mind prior to installing the modules in an open rack. It also contains information that applies

More information

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1000P Non-Powered Short Haul Modem C E R T I F I E D An ISO-9001 Certified Company Part #07M1000PA Doc. #022031UA Revised 2/17/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007

More information

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

1. Carefully unpack the um260 s shipping carton and check the contents for damage. um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing

More information

Perle MCR200 Installation Guide

Perle MCR200 Installation Guide Perle MCR200 Installation Guide P/N 5500322-10 Introduction The Perle MCR200 Chassis is a 2 slot chassis able to accommodate up to 2 Perle Media Converter modules or 1 Media Converter Module and an MCR-MGT

More information

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem USER MANUAL MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem An ISO-9001 Certified Company Part #07M1003-B Doc. #050021UB Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL

More information

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input. LMC5103A-R2 1-slot Multipower Desktop Chassis (Module Not Included) This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power

More information

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

Product names mentioned in this manual may be trademarks or registered trademarks of those products. FCC Statement The FCC (Federal Communications Commission) restricts the amount of radio frequency emission and radiation coming from computer equipment. The equipment introduced in this manual has been

More information

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT 4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with

More information

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input. LNP-0500-24 series 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input User Manual FCC Warning This Equipment has been tested and found to comply with

More information

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL

More information

G.SHDSL NTU with Fixed Serial Interfaces

G.SHDSL NTU with Fixed Serial Interfaces DECEMBER 2006 ME231A ME232A ME233A G.SHDSL NTU with Fixed Serial Interfaces CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support,

More information

UR51 Industrial Cellular Router

UR51 Industrial Cellular Router UR51 Industrial Cellular Router Quick Start Guide 1 Ursalink Technology Co., Ltd. Welcome Thank you for choosing Ursalink UR51 industrial cellular router. This guide describes how to install the UR51 and

More information

Installation and Operation Manual. Ethernet Interface for SIMREX Radio Modems. SIMREX P/N: MAN.UBRIDGE Rev. B APRIL 2005

Installation and Operation Manual. Ethernet Interface for SIMREX Radio Modems. SIMREX P/N: MAN.UBRIDGE Rev. B APRIL 2005 Installation and Operation Manual SIMREX Corporation ubridge Ethernet Interface for SIMREX Radio Modems SIMREX P/N: MAN.UBRIDGE Rev. B APRIL 2005 SIMREX CORPORATION Your Trusted Wireless Solution Provider

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

G.SHDSL NTU DECEMBER 2006 LB510A

G.SHDSL NTU DECEMBER 2006 LB510A DECEMBER 2006 LB510A G.SHDSL NTU CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

SitePORTAL Lite TA-SPL32-R48

SitePORTAL Lite TA-SPL32-R48 SitePORTAL Lite TA-SPL32-R48 Quick Connect Guide The TA-SPL32-R48 is a 19 inch, 2 RU rack mountable siteportal Lite (spl). It comes with 8 analog inputs, 8 temperature inputs (sensors sold separately),

More information

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

Mercury Helios ASSEMBLY MANUAL & USER GUIDE Mercury Helios ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards NOTE: Boot Camp

More information

Installing Power Modules

Installing Power Modules This chapter contains the procedures for installing cards and modules into the chassis after the chassis has been installed into a rack. This chapter also describes how to connect cables to RSP, RP, alarm,

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

Power Supply Installation

Power Supply Installation Power Supply Module Overview, on page Installation Guidelines, on page 4 Installing or Replacing an AC Power Supply, on page 6 Installing a DC Power Supply, on page 7 Finding the Power Supply Module Serial

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.

More information

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-COM Modules Installation Guide UAC-01RS2,UAC-02RS2,UAC-02RSC Uni-COM is a family of communication modules that are compatible with the UniStream control platform. This guide provides basic installation

More information

UniStream CPU-for-Panel

UniStream CPU-for-Panel UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UIA-0402N Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

HEC. General Operating, Maintenance and Installation Manual

HEC. General Operating, Maintenance and Installation Manual HEC General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet : http://www.ipcomm.de Email: info@ipcomm.de Edition November 2005 Version

More information

Modular Connectors 75

Modular Connectors 75 75 Plug/Jack Compliant to Enhanced Category 5 standards Connector type Size Series Name Page plug connectors compliant to enhanced category 5 standards 8 TM21P 77 jack connectors for high-speed LAN transmission

More information

Installation Instructions for UL Rev A

Installation Instructions for UL Rev A NetController II Installation Instructions for UL 864 30-3001-1008 Rev A Mounting Screw Andover Continuum Power Supply Connector Third-Party Power Supply Connector I/O Bus Connector Cover Mounting Screw

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

Installation Manual. Table of Contents

Installation Manual. Table of Contents Table of Contents Table of Contents... 4-1 4.1 Confirming the Installation Preparations... 4-1 4.2 Installation Flowchart... 4-1 4.3 Mounting the Switch to the Designated Position... 4-2 4.3.1 Mounting

More information

RocketPort Plus Hardware Installation

RocketPort Plus Hardware Installation RocketPort Plus Hardware Installation Introduction This Hardware Installation document discusses the following information: Product overview RocketPort terminology Before installing the hardware Installing

More information

DeviceMaster RTS 16-Port Hardware Installation

DeviceMaster RTS 16-Port Hardware Installation DeviceMaster RTS -Port Hardware Installation Red underscored text link to Internet URLs. Blue underscored text link to sections within this document or to another document in the library. Note: If you

More information

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents. User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply

More information

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1018 High Speed Short Range Modem w/ Extra Controls Part# 07M1018-B Doc# 013021UB Revised 11/3/95 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION

More information

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com

More information

PCI Hardware Installation

PCI Hardware Installation PCI Hardware Installation Product Overview The RocketPort PCI series multiport serial card fits into the PCI slot of a personal computer, and uses a 36 MHz processor that is specifically designed to process

More information

Product Data Sheet. BMS/Graphics Interface. Features

Product Data Sheet. BMS/Graphics Interface. Features BMS/Graphics Interface Product Data Sheet Features The Mxp-010 interface allows BMS systems and graphics PCs to be integrated with the Mx- 4000 series of Fire Control Panels and Remote Terminals. The interface

More information

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

AS1008-P AS1026-P AS2008-P AS2024-P User Manual Fast Ethernet and Gigabit Ethernet PoE+ Unmanaged Switches AS1008-P AS1026-P AS2008-P AS2024-P User Manual Version 1.0.0.1 Sep 2017 Contents Compliances and Safety Statements... 3 1. AS1000 Series Product

More information

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP AX3000 Platine Terminal Ethernet TCP/IP Model 85B Installation Guide September 2013 - Ref: I85BE0922-1 Model AX3000/M85B The reproduction of this material, in part or whole, is strictly prohibited. For

More information

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas.

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas. Industrial Opto-Isolated RS-232 to RS-422/485 Converter Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas. Rugged IP30-rated metal case for panel mounting. Quick Start Guide Customer

More information

INJ-24A Series Quick Installation Guide

INJ-24A Series Quick Installation Guide INJ-24A Series Quick Installation Guide Moxa High-Power PoE+ Injector Edition 4.1, August 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

M40e and M160 CIP Installation Instructions

M40e and M160 CIP Installation Instructions Part No. 530-005365-01 Revision 2 23 January 2002 CIP Description This document describes how to remove and replace the Connector Interface Panel (CIP) on a Juniper Networks M40e Internet router or M160

More information

Installation and Maintenance

Installation and Maintenance CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,

More information

VPN Routers. OnSite 2800 Series. Quick Start Guide

VPN Routers. OnSite 2800 Series. Quick Start Guide OnSite 2800 Series VPN Routers Quick Start Guide Part Number: 07M2800-QS, Rev. E Revised: February 22, 2012 Sales Office: +1 (301) 975-1000 Technical Support: +1 (301) 975-1007 E-mail: support@patton.com

More information