G.M. International S.r.l. Via Mameli, Villasanta (MB) - ITALY

Size: px
Start display at page:

Download "G.M. International S.r.l. Via Mameli, Villasanta (MB) - ITALY"

Transcription

1 Notes NET = Net Pricing, NOT discountable SV = Special Version; Non Stock Delivery NA = Not Yet Available NC = Free of Charge D = Din Rail Mounting DB = Power Bus Mounting BR = Board Mounting R = Rack Mounting PA = Panel Mounting FL = Flush Mounting PO = Pole Mounting LP = Loop Power FF = Fully Fitted Enclosure: Including Bottom Plate, DIN Rail, Earthing Bar, FF = Fully Fitted Enclosure: Including Bottom Plate, DIN Rail, Earthing Bar, Wall Mounting Brackets, Double Terminals Blocks for Redundand Line Shield connections, DIN Rail Stoppers in Number and Type Specified. Sizes in mm SIL Rating according to IEC6508/65 G.M. International S.r.l. Via Mameli, Villasanta (MB) - ITALY Tel. : Fax : info@gmintsrl.com Web Site : Price List 206 ( Rev. dated March st, 206 )

2 G.M. International srl Via San Fiorano, Villasanta (MB) - Italy Tel. : Fax : info@gmintsrl.com - Web : Price List 206 ( Rev. dated March st, 206 ) Page # 2 ANALOGUE INPUT I.S. MODULES D00S Ch; Smart-Hart; Active-Passive Input; Sink-Source Output; SIL D00D 2 Ch; Smart-Hart; Active-Passive Inputs; Sink-Source Outputs; Duplicator; SIL 2 D00S-026 Ch; 4-20 ma Input; 0-20 ma / 0-0 V Output D00D Ch; 4-20 ma Inputs; 0-20 ma / 0-0 V Outputs; Duplicator 2 D00S-046 Ch; Smart-Hart; Active-Passive Input; Sink-Source Output; Low I.S. Parameters; SIL D00D Ch; Smart-Hart; Active-Passive Inputs; Sink-Source Outputs; Duplicator; Low I.S. Parameters; SIL 2 D00S-047 Ch; 4-20 ma Input; 0-20 ma / 0-5 V Output D00D Ch; 4-20 ma Inputs; 0-20 ma / 0-5 V Outputs; Duplicator 2 D00S-054 Ch; -5 to +55 mv Input; 4-20 ma Output D00S-056 Ch; -5 to +35 mv Input; 4-20 ma Output D00S-057 Ch; -5 to +0 mv Input; 4-20 ma Output D02Q 4 Ch; 4-20 ma Passive non Isolated Inputs; 4-20 ma Source Outputs ; Factory Programmable Splitter 4 D04S Ch; Hart; 4-20 ma Passive Input; 4-20 ma Sink-Source Output; SIL D04S-060 Ch; Hart; 4-20 ma Passive Input; 4-20 ma Source Output up to KΩ Load; D04S-083 Ch; Hart; 4-20 ma Passive Input; 2-0 Volt Output; D04D Independent Ch; Hart; 4-20 ma Passive Inputs; 2-0 Volt Outputs; 2 D04D 2 Independent Ch; Hart; 4-20 ma Passive Inputs; 4-20 ma Sink-Source Outputs; SIL 2 D50S Ch; 4-20 ma 2-Wire IN; 4-20mA Source OUT; Hart; SIL 2 D50D 2 Ch; 4-20 ma 2-Wire IN; 4-20mA Source OUT; Hart; SIL D504S Ch; 4-20 ma, 2/3-Wire IN; ma/v Sink/Source OUT; Hart; SIL 2 D504D 2 Independent Ch; 4-20 ma, 2/3-Wire IN; ma/v Sink/Source OUT; Hart; SIL Note: Unit is field configurable as Duplicator IN - 2 OUTs D505S Ch; 4-20 ma, 2/3-Wire IN; 4-20mA Source OUT; Hart; S/K/V Versions Available; SIL 2 D505D 2 Ch; 4-20 ma, 2/3-Wire IN; 4-20mA Source OUT; Hart; S/K/V Versions Available; SIL Note: Unit is field configurable as Duplicator IN - 2 OUTs D522Q 4 Ch; 4-20 ma IN/OUT; Configurable as Duplicator, Triplicator or Quadruplicator 4 ANALOGUE OUTPUT I.S. MODULES D020S Ch; Smart-Hart; Isolating Driver for I/P; 0/4-20 ma IN-OUT; SIL D020D 2 Independent Ch; Smart-Hart; Isolating Driver for I/P; 0/4-20 ma IN-OUT; SIL 2 D020S-027 Ch; Isolating Driver for I/P; Input 2-0 V; Output 4-20 ma D020D Ch; Isolating Driver for I/P; Input 2-0 V; Output 4-20 ma 2 D020S-050 Ch; Isolating Driver for I/P; Input 0-0 V; Output 4-20 ma D020D Ch; Isolating Driver for I/P; Input 0-0 V; Output 4-20 ma 2 D020S-067 Ch; Isolating Driver for I/P; Input - 5 V; Output 4-20 ma D020D Ch; Isolating Driver for I/P; Input - 5 V; Output 4-20 ma 2 D0S Ch; Gas-Fire Detector Interface; Loop Powered -40 ma IN/OUT D0D 2 Ch; Gas-Fire Detector Interface; Loop Powered -40 ma IN/OUT 2 D5020S Ch; 4-20 ma, I/P Driver; Transparent Open-Short Circuit Alarm Function; Hart SIL 2 D5020D 2 Independent Ch; 4-20 ma, I/P Driver; Transparent Open-Short Circuit Alarm Function; SIL Note: Unit is field configurable as Duplicator IN - 2 OUTs

3 Price List 206 ( Rev. dated March st, 206 ) Page # 3 DIGITALI INPUT I.S. MODULES D030S Ch; + Relay Output SPDT (Duplication or LFD Alarm); Line Monitoring Function; SIL D030D 2 Ch; 2 Relay Outputs SPDT; Line Monitoring Function; SIL 2 D30S Ch; + Relay Output SPDT (Duplication or LFD Alarm); Line Monitoring Function; AC Power; SIL D30D 2 Ch; 2 Relay Outputs SPDT ; Line Monitoring Function; AC Power; SIL 2 D030S-08 Ch; + Relay Output SPDT (Duplication or LFD Alarm); Line Monitoring Function; 2VDC Power D030D-08 2 Ch; 2 Relay Outputs SPDT; Line Monitoring Function; 2 VDC Power Supply 2 D03D 2 Ch; 2+2 OC Transistor Outputs (Duplication or LFD Alarm); Line Monitoring Function; KHz Max; SIL 2 D03Q 4 Ch; 4 OC Transistor Outputs; Line Monitoring Function; KHz Max; SIL 4 D032D 2 Isolated Ch; 2+2 Relay Outputs SPST (Duplication or LFD Alarm); Line Monitoring Function; SIL 2 D032Q 4 Isolated Ch; 4 Relay Outputs SPST, Line Monitoring Function; SIL 4 D033D 2 Isolated Ch; 2+2 OC Transistor Outputs (Duplication or LFD Alarm); Line Monitoring Function; SIL 2 D033Q 4 Isolated Ch; 4 OC Transistor Outputs; Line Monitoring Function; SIL 4 D033D Iso. Ch; 2+2 OC Trans. Out (Dupl. or LFD Alarm); Line Mon. Func; Common Negative; 2 D033Q Isolated Ch; 4 OC Transistor Outputs; Line Monitoring Function; Common Negative; 4 D033D Iso. Ch; 2+2 OC Trans. Out (Dupl. or LFD Alarm); Line Mon. Func; Common Positive; 2 D033Q Isolated Ch; 4 OC Transistor Outputs; Line Monitoring Function; Common Positive; 4 D034S Ch; Trasparent to Contact-Proximity & Line Monitoring Function; SIL D034D 2 Independent Ch; Trasparent to Contact-Proximity & Line Monitoring Function; SIL 2 D5030S Ch; SPDT Relay Output; Line Monitoring Function; SIL 2 D5030D 2 Independent Ch; 2 SPST Relay Outputs; Line Monitoring Function; SIL Note: Unit is field configurable as Duplicator: IN / 2 OUTs or IN - + OUT (DI + LFD) D503S Ch; NO/NC Solid State Output; Line Monitoring Function; SIL 2 D503D 2 Independent Ch; 2 NO/NC Solid State Out; Line Monitoring Function; SIL Note: Unit is field configurable as Duplicator: IN / 2 OUTs or IN - + OUT (DI + LFD) D523E 8 Ch; NO/NC Solid State Output; Line Monitoring Function; Fully Programmable; SIL 8 Note: Unit is field fully configurable as Duplicator; Triplicator; etc. : up to IN / 8 OUTs or any combinations. D5032S Ch; SPST Relay Output; Line Monitoring Function; SIL 2 D5032D 2 Independent Ch; 2 SPST Relay Outputs; Line Monitoring Function; SIL Note: Unit is field configurable as Duplicator: IN / 2 OUTs or IN - + OUT (DI + LFD) D5034S Ch; Trasparent to Contact-Proximity & Line Monitoring Function; SIL 2 D5034D 2 Independend Ch; Trasparent to Contact-Prox & Line Monitoring Function; SIL D5036S Ch; SPDT Relay Output; Line Monitoring Function; SIL; No G3 Coating. 2 D5036D 2 Ch; 2 SPST Relay Outputs; Line Monitoring Function; SIL; No G3 Coating. D5037S Ch; NO/NC Solid State Output; Line Monitoring Function; SIL; No G3 Coating. 2 D5037D 2 Ch; 2 NO/NC Solid State Outputs; Line Monitoring Function; SIL; No G3 Coating. DIGITALI INPUT NON I.S. MODULES D5093S Ch; AC (24 to 0 Vac/Vdc) Digital Input Module; SIL 2 D5093D 2 Ch; AC (24 to 0 Vac/Vd) Digital Input Module; SIL

4 Price List 206 ( Rev. dated March st, 206 ) Page # 4 DIGITAL OUTPUT I.S. MODULES 4 Separated Channels; ma Imax; 334 Ω; SIL 4 D040Q Channels in parallel; ma Imax; 67 Ω; SIL 2 3 Channels in parallel; 26 ma Imax; Ω; SIL 4 Channels in parallel; 288 ma Imax; 84 Ω; SIL D04Q 4 Channels to drive LEDs; ,6 ma Imax; 484 Ω; SIL 4 4 Separated Channels, ,2 ma Imax; 273 Ω; SIL 4 D042Q Channels in parallel, ,4 ma Imax; 37 Ω; SIL 2 3 Channels in parallel, 264,6 ma Imax; 9 Ω; SIL 4 Channels in parallel, 352,8 ma Imax; 68 Ω; SIL 4 Separated Channels, ,6 ma Imax; 484 Ω; SIL 4 D043Q Channels in parallel, ,2 ma Imax; 242 Ω; SIL 2 3 Channels in parallel, 48,8 ma Imax; 6 Ω; SIL 4 Channels in parallel, 98,4 ma Imax; 2 Ω; SIL D045Y 2 Channels for ATOS Valve 249/307 ma Imax; 8/68 Ω (Alternating Channels) D046Y 2 Channels for WANDFLUH Valve 366 Imax; 68 Ω (Alternating Channels) 2 D048S Ch; NE Loads; Loop Powered; Line & Valve Monitoring Function; Selectable Output; SIL D049S Ch; NE Loads; Bus Powered; Line & Valve Monitoring Function; Selectable Output; SIL D5048S D5049S Ch; Solenoid Driver; Loop Powered; Transparent Line & Load Alarm Function; SIL Note: Unit has three field selectable Valve power Outputs; Both Open and Short Circuit Fault Detection Ch; Solenoid Driver; Bus Powered; Line & Load Alarm Function; SIL Note: Unit has three field selectable Valve power Outputs; Both Open and Short Circuit Fault Detection 2 2 D5040S Ch; Solenoid Driver; Loop Powered; SIL Note: Unit has two field selectable Valve power Outputs; D5040D 2 Ch; Solenoid Driver; Loop Powered; SIL Note: Unit has two field selectable Valve power Outputs; D5240T 3 Ch; Solenoid Driver; Bus Powered; SIL 3 Note: Unit has three field selectable Valve power Outputs; DIGITAL OUTPUT / RELAY OUTPUT I.S. MODULES D044S Channel; SPDT Relay Output to Hazardous Location D044D 2 Channel; 2 SPDT Relay Outputs to Hazardous Location; SIL 2 D5244S Channel; SPDT Relay Output to Hazardous Location; SIL D5244D 2 Channel; 2 SPDT Relay Outputs to Hazardous Location; SIL 2

5 Price List 206 ( Rev. dated March st, 206 ) Page # 5 SIGNAL CONDITIONERS & TRIP AMPLIFIERS I.S. MODULES D052S Ch; ma, V - Input, Output; Fully Software Programmable; D052D 2 Ch; ma, V - Input, Output; Fully Software Programmable; 2 D052X Input-2 Outputs Ch; Duplicator; ma, V - Input, Output; Fully Software Programmable D052Y 2 Ch; ma, V - Input, Output; High-Low Selector / Adder / Subtractor; Fully Software Programmable 2 D053S Ch; ma, V - Input, Output + 2 Trip Amplifiers; Fully Software Programmable; SIL D053S-02 Ch; ma, V - Input, Output + 2 Trip Amplifiers; Fully Software Programmable; 2 Vdc Power Supply; D054S Ch; Smart-Hart; 0/4-20 ma Input; ma-v Output + 2 Trip Amp; Fully Software Programmable; SIL D5254S Ch; Smart-Hart; 0/4-20 ma Input; ma-v Output + 2 Trip Amp; Fully Software Programmable; SIL 2 TEMPERATURE INPUT I.S. MODULES D072S Ch; TC-RTD-Tx Pot Input; ma-v Output; Fully Software Programmable; SIL D072D 2 Ch; TC-RTD-Tx Pot Input; ma-v Outputs; Fully Software Programmable; SIL 2 D072S-024 Ch; 0-80 or 6-80 mv Input / Output; D072D Ch; 0-80 or 6-80 mv Input / Output; 2 D072D Ch; Input & Output According to APN D073S Ch; TC-RTD-Tx Pot IN; ma-v Output + 2 Trip Amplifiers; Fully Software Programmable; SIL D073S-0 Ch. TC-RTD-Tx Pot IN; ma-v Output + 2 Trip Amp; Fully Software Programmable; 2Vdc Power Supply D5072S Ch; TC-RTD-Tx Pot Input; ma plus Burnout Alarm Outputs; Fully Programmable, SIL 2 D5072S-087 Ch; RTD Input; RTD Output; 2 D5072D 2 Ch; TC-RTD-Tx Pot Input; ma Outputs; Fully Programmable, SIL Note: Unit is field configurable as Duplicator IN - 2 OUT D5273S Ch; TC-RTD-Tx Pot Input; ma Outputs; + 2 Trip Amplifiers; Fully Programmable, SIL TEMPERATURE INPUT NON I.S. MODULES D072D Ch; TC-RTD-Tx Pot Input; ma-v Outputs; Fully Software Programmable; 2 FREQUENCY INPUT I.S. MODULES D035S Ch; Contact-Prox-LL-Magnetic Pick-up Input; 0-50 KHz Range; Pulse (Open Collector) Output D060S Ch; Cont-Prox-LL-Magnetic Pick-up Input; 0-50 KHz Range; Pulse + ma-v + Trip Ampl. Outputs; Note: Fully Software Programmable D060S-049 Ch; Cont-Prox-LL-Magnetic Pick-up Input; 0-50 KHz Range; Pulse + ma-v + Trip Ampl. Outputs; Note: Special Version with Clamping Diode; Fully Software Programmable D5060S Ch; 0-50 KHz Frequency Input; Analog Output plus Pulse Repeat or Alarm Output 2 D06S D06S-077 D062S D5062S SERIAL LINE I.S. MODULES FieldBus / ModBus Isolated Interface; Communication speed up to,5 M bit/sec; Note: Hazardous Areas: RS485, RS4; Safe Areas: RS485, RS4, RS232 FieldBus / ModBus Isolated Interface; Communication speed up to,5 M bit/sec; Note: Hazardous Areas: RS485, RS4; Safe Areas: RS485, RS4, RS232; Lower Safety Parameters VIBRATION INPUT I.S. MODULES Vibration Monitor Sensors Isolated Interface; Note: Input from Bentley Nevada, BK & Vibrometer Sensors Vibration Monitor Sensors Isolated Interface; SIL Note: Input from Bentley Nevada, BK & Vibrometer Sensors 2

6 Price List 206 ( Rev. dated March st, 206 ) Page # 6 D063S D064S to 4 parallel 350 Ohm Load Cell Input; 5V, 80 ma total capability; 6-Wire IN-OUT; Note: Fully Transparent; Division Accuracy to 4 parallel 350 Ohm Load Cell Input; 5V, 80 ma total capability; 6-Wire Input; 4-20 ma & Modbus Output; Note: Division Accuracy; Automatic Bridge Calibration System D5263S to 4 parallel 350 Ohm Load Cell Input; 5V, 80 ma total capability; 6-Wire IN-OUT; SIL Note: Fully Transparent; Division Accuracy D5264S to 4 parallel 350 Ohm Load Cell Input; 5V, 80 ma total capability; 6-Wire Input; 4-20mA & Modbus Out; SIL Note: Division Accuracy; Automatic Bridge Calibration System LOAD CELL INPUT I.S. MODULES ANALOG INPUT NON I.S. MODULES D00D Ch; 0-5 Vdc Input; 4-20 ma Output; Fix Range 2 D00S-00 Ch; Vdc Input; 4-20 ma Output; Fix Range D00S-05 Ch; 0-50 Vdc Input; 4-20 ma Output; Fix Range D00S-06 Ch; 0-20 mvdc Input; 4-20 ma Output; Fix Range D00S-07 Ch; Vdc Input; 4-20 ma Output; Fix Range D00S-023 Ch; Vdc Input; 4-20 ma Output; Fix Range D00D Ch; ma Input; 0-20 ma Output; Fix Range 2 D00D Ch; 0-0 Vdc Input; 4-20 ma Output; Fix Range 2 D00D Ch; 0-5 Vdc Input; 4-20 ma Output; Fix Range 2 D00S-038 Ch; Vdc Input; 4-20 ma Output; Fix Range D00S-055 Ch; 0-70 Vdc Input; 4-20 ma Output; Fix Range D00D-06 2 Ch; 0-40 Vdc Input; 4-20 ma Output; Fix Range 2 FLAMMABLE LIQUID DETECTOR INPUT I.S. MODULES D080D 2 Ch; Relay Output SPDT; Suitable for 3 Wire probes 2 D08D 2 Ch; O.C. Transistor Outputs; Suitable for for 3 Wire probes 2 D80D 2 Ch; Relay Output SPDT; Suitable for for 3 Wire probes; AC Power Supply 2 POWER SUPPLY MODULES PSD000 Zone 2 Power Supply; 24 VDC - 0,6 A Output; For AC power of D000 Modules PSD000F Power Supply; 24 VDC - 0,6 A Output; For AC power of D000 Modules with Alarm PSD00 I.S. Power Supply; 4 Parallelable Outputs each with 5 V - 20 ma; SIL 4 PSD00C I.S. Power Supply IIB-IIA Group; 3.5 V -00 ma Output ; SIL PSD520 I.S. Power Supply IIB-IIA Group; 4.5 V -50 ma Output ; SIL PSD200 Series PSD20/IP66 Zone 2 Power Supply; II 3 G EEx na IIC T4; 24 V - 0 A Output; IP66; SIL 200 PSS200 Series PSW250 Zone 2 Power Supply Module; 24 V - 50 A Output; Wall Mounting (DinRail aval.); SIL 6 PSW230 Zone 2 Power Supply Module; 24 V - 30 A Output; Wall Mounting (DinRail aval.); SIL 6 PSM250 Zone 2 Power Supply Module; 24 V - 50 A Output; Rack Mounting; SIL - - PSO250 Zone 2 Power Supply Display/Diagnostic Module; RS-485 ModBus Output. Rack Mounting; Optional - - PSS250-HS-7--D 9" Rack for N 6 PSM250 + N PSO250 Module; Zone 2 Hot swapping; Amps PSS250-HS-7-2-D 9" Rack for N 6 PSM250 + N PSO250 Module; Zone 2 Hot swapping; & Amps PSS250-HS-7-3-D 9" Rack for N 6 PSM250 + N PSO250 Module; Zone 2 Hot swapping; N 3 x Amps PSS D 9" Rack for N 6 PSM250 + N PSO250 Module; Zone 2; Amps PSS D 9" Rack for N 6 PSM250 + N PSO250 Module; Zone 2; & Amps PSS D 9" Rack for N 6 PSM250 + N PSO250 Module; Zone 2; N 3 x Amps PSS250-HS-3-D 9" Rack for N 2 PSM250 + N PSO250 Module; Zone 2 Hot swapping; Amps PSS250-3-D 9" Rack for N 2 PSM250 + N PSO250 Module; Zone 2; Amps MCHP 8 Blank Panel for empty position of PSS250 rack series - -

7 Price List 206 ( Rev. dated March st, 206 ) Page # 7 SIL 3 RELAY MODULES D092S D092S-069 D092D D092D-069 D093S Ch; SIL3 Relay; Out: N 2 SPST NO Relay ( for NE Loads & for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or Energized Relay / Energized Load; Not Comp. to L.M. Pulses. Ch; SIL3 Relay; Out: N 2 SPST NO/NC Relay ( for NE Loads & for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or De-energized Relay / Energized Load; Not Comp. to L.M. Pulses. 2 Ch; SIL 3 Relay; Out: N 4 SPST NO Relay (2 for NE Loads & 2 for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or Energized Relay / Energized Load; Not Comp. to L.M. Pulses. 2 Ch; SIL 3 Relay; Out: N 4 SPST NO/NC Relay (2 for NE Loads & 2 for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or De-energized Relay / Energized Load; Not Comp. to L.M. Pulses. Ch; SIL3 Relay; Out: N 2 SPST NO Relay ( for NE Loads & for ND Loads); SIL Note: With Line Open Circuit Detection for NE or ND Loads; Note: Safety Function is De-energ. Relay / De-energ. Load or Energized Relay / Energized Load; Not Comp. to L.M. Pulses. 2 2 D5090S D5090S-086 D509S D5094S D5095S D5096S D5097S Ch; SIL3 Relay for NE Load; SPST NO 5 Amps contacts plus Service Output; SIL Note: Safety Function is De-energized Relay / De-energized Load. Ch; SIL3 Relay for NE Load; SPST NC 5 Amps contacts plus Service Output SIL Note: Safety Function is Energized Relay / De-energized Load. Ch; SIL3 Relay for ND Load; SPDT 5 Amps contacts with Service Output; SIL Note: Safety Function is Energized Relay / Energized Load or De-energized Realy / Energized Load. Ch; SIL3 Relay for NE or ND Load; SPST NO 5 Amps contacts; SIL Note: Safety Function is De-energ. Relay / De-energ. Load or Energ. Relay / Energ. Load; Fault Tolerant for increased availability. Ch; SIL3 Relay for NE or ND Load; SPST NO 5 Amps contacts; SIL Note: Safety Function is De-energ. Relay / Energ. Load or Energ. Relay / De-energ. Load; Fault Tollerant for increased availability. Ch; SIL3 Relay for NE or ND Load; SPST NO 5 Amps contacts; SIL Note: With Line-Load Open and Short Circuit, Supply Voltage; Note: Safety Function is De-energ. Relay / De-energ. Load or Energ. Relay / Energ. Load; Fault Tolerant for increased availability. Ch; SIL3 Relay for NE or ND Load; SPST NO 5 Amps contacts; SIL Note: With Line-Load Open and Short Circuit, Supply Voltage; Note: Safety Function is De-energ. Relay / Energ. Load or Energ. Relay / De-energ. Load; Fault Tollerant for increased availability. D5098S Ch; SIL3 Relay for NE Load; SPST NO 5 Amps contacts plus Service Output; SIL Note: Safety Function is De-energized Relay / De-energized Load. Current consumption limited to 20 ma 2 D5098D 2 Ch; SIL3 Relay for NE Load; SPST NO 5 Amps contacts plus Service Output; SIL Note: Safety Function is De-energized Relay / De-energized Load. Current consumption limited to 20 ma 2 D5290S D5290S/SA D5290S-078 D5290S-078/SA D5290S-079 D5290S-080 D5290S-084 D5290S-09 D529S D5292S Ch; SIL3 Relay for NE Load; SPST NO 0 Amps contacts plus Service Output; SIL Note: Safety Function is De-energized Relay / De-energized Load. Ch; SIL3 Relay for NE Load; SPST NO 0 Amps contacts plus Service Output; SIL Note: Safety Function is De-energized Relay / De-energized Load / Safe Area only / Not Compatible to L.M. Pulses. Ch; SIL3 Relay for NE/ND Load; 2 SPDT + 2 SPST NO 5 Amps contact; SIL Note: Safety Function is De-energ. Relay/De-energ. Load or Energ. Relay/Energ. Load or De-energized Relay/Energized Load. Ch; SIL3 Relay for NE/ND Load; 2 SPDT + SPST NO 5 Amps contacts; SIL Note: Safety Function is De-energ. Relay/De-energ. Load or De-energ. Relay/Energ. Load / Safe Area only / Not Comp. to L.M. Pulses. Ch; SIL3 Relay for NE/ND Load; 2 SPDT + 2 SPST NO 5 Amps contacts; 5Vac Coil ; SIL Note: Safety Function De-energ. Relay/De-energ. Load or De-energ. Relay/Energ. Load Safe Area only / Not Comp. to L.M. Pulses. Ch; SIL3 Relay for NE Load; SPST NO 0 Amps contacts plus Service Output; 5Vac Coil; SIL Note: Safety Function is De-energized Relay / De-energized Load / Safe Area only / Not Compatible to L.M. Pulses. Ch; SIL3 Relay for NE/ND Load; 2 SPDT + 2 SPST NO 5 Amps contacts; 0Vdc Coil ; SIL Note: Safety Function De-energ. Relay/De-energ. Load or De-energ. Relay/Energ. Load Safe Area only / Not Comp. to L.M. Pulses. Ch; SIL3 Relay for NE Load; SPST NO 0 Amps contacts plus Service Output; 230Vac Coil; SIL Note: Safety Function is De-energized Relay / De-energized Load / Safe Area only / Not Compatible to L.M. Pulses. Ch; SIL3 Relay for ND Load; SPDT 0 Amps contacts with Service Output; SIL Note: Safety Function is Energized Relay / Energized Load or De-energized Relay / Energized Load. Ch; SIL3 Relay; Out: N 2 SPST NO Relay ( for NE Loads & for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or Energized Relay / Energized Load; D5292S-093 D5292D D5292D-093 D5293S D5294S Ch; SIL3 Relay; Out: N 2 SPST NO/NC Relay ( for NE Loads & for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or De-energized Relay / Energized Load; 2 Ch; SIL 3 Relay; Out: N 4 SPST NO Relay (2 for NE Loads & 2 for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or Energized Relay / Energized Load; 2 Ch; SIL 3 Relay; Out: N 4 SPST NO/NC Relay (2 for NE Loads & 2 for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or De-energized Relay / Energized Load; Ch; SIL3 Relay for NE Load; + SPST NO 4 Amps contacts plus Fault Output; SIL Note: With Line-Load Open and Short Circuit, Supply Voltage, & Relay Coil Short Circuit Detection; RS485 Output; Note: Safety Function is De-energized Relay / De-energized Load. Ch; SIL3 Relay for ND Load; 2 +2 SPST NO 4 Amps contacts plus Fault Output; SIL Note: With Line-Load Open and Short Circuit, Supply Voltage, Hearth Leakage & Relay Coil Short Circuit Detection; RS485 Output; 2 2 Note: Safety Function is De-energ. Relay / De-energ. Load or Energ. Relay / Energ. Load; Fault Tolerant for increased availability. Ch; SIL3 Relay for ND Load; 2 +2 SPST NC 4 Amps contacts plus Fault Output; SIL D5295S Note: With Line-Load Open and Short Circuit, Loss of Power, Earth Leackage Detection; RS485 Output; Note: Safety Function is De-energ. Relay / Energ. Load or Energ. Relay / De-energ. Load; Fault Tollerant for increased availability.

8 Price List 206 ( Rev. dated March st, 206 ) Page # 8 HART MULTIPLEXER D5400 Series D5400 Hart Multiplexer Master; Compatbile with Hart Multiplexer boards TB-D5000-HRT-00 & 002; SIL - 2 SURGE PROTECTION DEVICES D9000 Series D9024S Ch; Floating signal circuit SPD (AI,AO,DI,DO); Din-rail version; disconnect knife; Nom.Volt. 24 VDC; SIL 6 D9324S Ch; Floating signal circuit SPD (AI,AO,DI,DO); Screw-on version; IP67; Nominal voltage 24 VDC; SIL - ISOLATORS FOR NON IS APPLICATIONS D6000 Series D605S Ch; 4-20 ma, 2/3-Wire IN; 4-20mA Source OUT; Hart; S/K Versions Available; SIL 2 D605D 2 Ch; 4-20 ma, 2/3-Wire IN; 4-20mA Source OUT; Hart; S/K Versions Available; SIL Note: Unit is field configurable as Duplicator IN - 2 OUTs D604S Ch; 4-20 ma, 2/3-Wire IN; ma/v Sink/Source OUT; Hart; SIL 2 D604D D622Q 2 Independent Ch; 4-20 ma, 2/3-Wire IN; ma/v Sink/Source OUT; Hart; SIL Note: Unit is field configurable as Duplicator IN - 2 OUTs 4 Ch; 4-20 ma IN/OUT; Configurable as Duplicator, Triplicator or Quadruplicator Note: Unit is field configurable as Duplicator, Triplicator or Quadruplicator; IN - 2,3 or 4 OUTs D6020S Ch; 4-20 ma, I/P Driver; Transparent Open-Short Circuit Alarm Function; Hart SIL 2 D6020D 2 Independent Ch; 4-20 ma, I/P Driver; Transparent Open-Short Circuit Alarm Function; SIL Note: Unit is field configurable as Duplicator IN - 2 OUTs D6030S Ch; SPDT Relay Output; Line Monitoring Function; SIL 2 D6030D 2 Independent Ch; 2 SPST Relay Outputs; Line Monitoring Function; SIL Note: Unit is field configurable as Duplicator: IN / 2 OUTs or IN - + OUT (DI + LFD) D603S Ch; NO/NC Solid State Output; Line Monitoring Function; SIL 2 D603D 2 Independent Ch; 2 NO/NC Transistor Out; Line Monitoring Function; SIL Note: Unit is field configurable as Duplicator: IN / 2 OUTs or IN - + OUT (DI + LFD) D623E 8 Ch; NO/NC Solid State Output; Line Monitoring Function; SIL 8 D6034S Ch; Trasparent to Contact-Proximity & Line Monitoring Function; SIL 2 D6034D 2 Independend Ch; Trasparent to Contact-Prox & Line Monitoring Function; SIL D6036S Ch; SPDT Relay Output; Line Monitoring Function; No G3 Coating; SIL 2 D6036D 2 Ch; 2 SPST Relay Outputs; Line Monitoring Function; No G3 Coating; SIL D6037S Ch; NO/NC Solid State Output; Line Monitoring Function; No G3 Coating; SIL 2 D6037D 2 Ch; 2 NO/NC Solid State Output; Line Monitoring Function; No G3 Coating; SIL D6254S Ch; Smart-Hart; 0/4-20 ma Input; ma-v Output + 2 Trip Amp; Fully Softw. Program; SIL D6072S Ch; TC-RTD-Tx Pot Input; ma plus Burnout Alarm Outputs; Fully Programmable, SIL 2 D6072S-087 Ch; RTD Input; RTD Output, SIL 2 D6072D 2 Ch; TC-RTD-Tx Pot Input; ma Outputs; Fully Programmable, SIL Note: Unit is field configurable as Duplicator IN - 2 OUT D6273S Ch; TC-RTD-Tx Pot Input; ma Outputs; + 2 Trip Amplifiers; Fully Programmable, SIL I.S. DISPLAY MODULES T3000 Series T300S 4-20 ma Intrinsically Safe 4.5 digit Indicator; Loop Powered; IP 65; Size 44x44x6 mm; 44 Note: 20 mm high Display; Suitable for Wall Mounting; Flush or Pipe mounting using OPT3092-OPT3093 OPT3092 Stainless Steel Bracket set and Gasket for Flush-Panel Mounting - - OPT3093 Stainless Steel Bracket set for mm Pipe Mounting & SS set for Flush-Panel Mounting - -

9 Price List 206 ( Rev. dated March st, 206 ) Page # 9 OPTIONS & ACCESSORIES BUS Extra Price for Power Bus Housing; Add: " /B " to model number - OPT096 Kit For Bus Mounting Include: N 2 MOR06, N MOR07, N MOR0, N 2 MCHP OPT097 Kit For Bus Mounting Include: N MOR05, N MOR0, N 2 MCHP MOR sqmm Terminal Block 4p, Blue Color (RAL505); Number Marking to be specified - - MOR sqmm Terminal Block 4p, Gray Color (RAL7042); Number Marking to be specified - - MOR 06 Din Rail Stopper - 0 MOR 05 Plug-in terminal block male, vertical out, for Power Bus - - MOR 07 Plug-in terminal block male, horizontal out, for Power Bus - - MOR 0 Plug-in terminal block female, horizontal out, for Power Bus - - MOR 046/2 Terminal Block for APN0005: Passive output for D05XX / D060S / D07XX ( for each channel) - 5 MOR 058 Terminal Block for PLC Pulse Damping of D09X relay - 5 MOR 062 Terminal Block with resistors KR Serie/0KR Parallel for LFD; Blue, Screw Connection; L70xH65xW5.2mm - 5 MOR 062/C Terminal Block Cover for MOR 062, blue; one needed for each group - 2 MCHP 044 D000 Serie Enclosure Gray; Marking to be specified - MCHP 06 D000 Serie BUS Enclosure Gray; Marking to be specified - MCHP 065 Din Rail Anchor for terminal block side of the Power Bus - 0 PPC090 Pocket Portable Configurator required to configure programmable units; includes CABF PPC092 PC Adapter to configure D000 series programmable units; Include CABF004-00, USB Adapter & SWC SWC090 Software for modules configuration via PPC092; Available on our web site free of charge - - CABF004 RJ 6 Poles Male-Male cable for connecting PPC090-PPC092 to D000 Serie Modules; - - CABF00 Sub D 9 Poles Female-Female Nul-Modem; 800 mm lenght - - CABF02 Load cells cable with N 3 twisted & screened sqmm pairs + overall screen (price x meter) - - USB adapter USB to serial line RS-232 Adapter; - - OPT09 Cold Junction Compensator to be ordered for THCs Inputs; One required for each input - GEST_CONF Extra Price for Module Configuration according to Customer Specification - - MCHP 064 Tagplate in policarbonate material - - MCHP mylar white lables for tagging (A4); Software for compilation on our web site free of charge - - MCHP 39 5 mm Spacer for spacing of modules on DIN Rail TS 35-5 MCHP 06/3 Dummy Bus module with Bus connector removed - D000D Dummy module to be used with custom boards PBCO series - D09S Common Alarm Module for with Fault Output, SPDT Relay Output D002S Redundant Power Connection & Common Alarm Module (SPST) for ; Max 4 Amp CABF030 Cable Assembly for PBCO; Connect Module Safe Area terminals to Board - - D000R 9" Rack unit, 3 units High, suitable for 6 D000 series modules D5000, D6000 & D9000 Series JDFT mm Power Bus Connector for DIN Rail Mounting; One needed for each BUS Module D5000-D JDFT 050 mm Power Bus Connector for DIN Rail Mounting; One needed for each BUS Module D5200-D MCHP96 Bus End Stopper; One for each end of Bus Required - 0 OPT5096 Kit For Bus Mounting Include: N MOR07, N MOR0, N 2 MCHP96 Note: One needed for each group of modules - - MOR 07 Plug-in terminal block male, horizontal out, for Power Bus - - MOR 0 Plug-in terminal block female, horizontal out, for Power Bus - - MOR sqmm Terminal Block 4p, Blue Color (RAL505) D5200-D6200; Number Marking to be specified - - MOR sqmm Terminal Block 2p, Blue Color (RAL505) D5000-D6000; Number Marking to be specified - - MOR sqmm Terminal Block 2p, Gray Color (RAL7042) D5000-D6000; Number Marking to be specified - - MOR sqmm Terminal Block 4p, Gray Color (RAL7042) D5200-D6200; Number Marking to be specified - - MOR 062 Terminal Block with resistors KR Serie/0KR Parallel for LFD; Blue, Screw Connection; L70xH65xW5.2mm - 5 MOR 062/C Terminal Block Cover for MOR 062, blue; one needed for each group - 2 MCHP 39 5 mm Spacer for spacing of modules on DIN Rail TS 35-5 MCHP83 Blue Terminal Block Plug 2 mm D MCHP84 Grey Terminal Block Plug 2 mm D5000-D MCHP85 Blue Terminal Block Plug mm D MCHP86 Grey Terminal Block Plug mm D5200-D MCHP242 End Cover for D9024S - 2 LABL0 Front Label Blue Colour (RAL505) 2mm, Page of 60 pcs D LABL02 Front Label Yellow Colour (RAL08) 2mm, Page of 60 pcs D LABL03 Front Label Blue Colour (RAL505) mm, Page of 60 pcs D LABL04 Front Label Yellow Colour (RAL08) mm, Page of 60 pcs D LABL06 Front Label Gray Colour (RAL7042) 2mm, Page of 60 pcs D5000-D LABL07 Front Label Gray Colour (RAL7042) mm, Page of 60 pcs D5200-D D5000D Dummy module with Hazardous Area & Safe AreaTerminal blocks; 2 mm - 2 D5200D Dummy module with Hazardous Area & Safe Area Terminal blocks; mm - D5000D/TBH Dummy module with Hazardous Area Terminal blocks; 2 mm - 2 D5200D/TBH Dummy module with Hazardous Area Terminal blocks; mm - D5000D/ENC Dummy module without Terminal blocks; 2 mm - 2 D5200D/ENC Dummy module without Terminal blocks; mm - D6000D Dummy module with Field & Control Room Terminal blocks; 2 mm - 2 D6200D Dummy module with Field & Control Room Terminal blocks; mm - D520S Common Alarm Module (SPST) for D5000/D6000 Series; D5202S Redundant Power Connection & Common Alarm Module (SPST) for D5000/D6000 Series; Max 4 Amps SWC5090 Software for configuration available on our web site free of charge - - PPC 5092 PC Adapter to configure D5000 & D6000 series programmable units; Include SWC5090 Software. - - G3_D5000 Extra Price for G3 coating for Non Coated SIL 2 modules; Add: " /G " to model number - - G3_TB Extra Price for G3 coating for Termination Boards; Add: " /G " to model number - - GEST_CONF Extra Price for Module Configuration according to Customer Specs. - -

10 Price List 206 ( Rev. dated March st, 206 ) Page # 0 DOCUMENTATION DOC_CERT_SAFETY Copy of I.S. Complete Certificate; Specify certificate type (IEC-Ex; ATEX; FM, UL, GHOST;..) - - DOC_CERT_TEST Copy of Individual Test certificate; One per each ordered instrument - - DOC_MANUAL Copy of Instruction Manuals in English Language; - - DOC_CONFORMITY Copy of EC Declaration of Conformity; - - DOC_CD_GM Copy of complete documentation set on CD Rom; One free copy included with each order; - - DOC_CERT_ORIGIN Certificate of Origin; Available only for export area outside of EC - - DOC_CERT_ORIG_GMI Certificate of Origin issue by GMI; Available only for export area outside of EC - - DOC_POSTER_EX Poster Intrinsic Safety Applications - - DOC_POSTER_SIL Poster SIL Applications - - DOC_SHORT_FORM_GM Short Form Catalogue - - Note Certificates, Data Sheets, Instruction Manuals free from our web site: TEMPERATURE AND DIGITAL I.S. MULTIPLEXER D200M D20M D2030M D2050M 6 Analog-temperature Input channels Intrinsically Safe Multiplexer unit, Note: For installation in hazardous Areas, in congiunction with the D2050M unit, Note: Din Rail Mounting. Up to n 4 D200M modules can be connected to a D2050M unit 6 Analog-temperature Input channels Intrinsically Safe Multiplexer-Expander unit, Note: For installation in hazardous Areas, in congiunction with the required D200M unit, Note: Din Rail Mounting, Up to n 3 D20M modules can be connected to a D200M unit. 32 Digital Input channels Intrinsically Safe Multiplexer unit, Note: For installation in hazardous Areas, in congiunction with the D2050M unit, Note: Din Rail Mounting, Up to n 4 D2030M modules can be connected to a D2050M unit Supply Interface unit with redundant comunication up to 4 Multiplexer units D200M-D2030M, Note: For installation in Safe Areas, Din Rail Mounting, Note: RTU Modbus redundant output line RS485 D2000 Series D2052M 32 Relay Output Module to repeat D2030M input, connection to D2050M 32 0 D2053M 32 Transistor Output Module to repeat D2030M input, connection to D2050M 32 0 OPTIONS & ACCESORIES D2000 Series D090Q 4 Channels Shunt Module for ma inputs of D200M & D20M Units 4 D094Q 4 Channels Divider Module for V inputs of D200M & D20M Units 4 OPT209 Cold Junction Compensator to be ordered for THCs Inputs Mounted on Terminal Block - Note: compensator per each D200M - D20M units OPT2094 Wall Mounting KIT for GM 2300 Series Enclosures - - OPT2095 Front Door Mounting KIT for GM 2300 Series Enclosures - - MOR 06 Din Rail Stopper - 0 MOR sqmm Terminal Block 4p, Blue Color (RAL505); - - MOR 045 Double Terminal Block to anchor CABF008 Line wires & shield - - CABF005 5 cm flat cable to interconnect D200M - D20M units - - CABF cm flat cable to interconnect D200M - D20M units - - CABF cm flat cable to interconnect D200M - D20M units - - CABF008 Cable to interconnect D2050M with D200M or D2030M units (price per meter), - - CABF0 5 cm flat cable to interconnect D2050M - D2052M - D2053M units - - CABF cm flat cable to interconnect D2050M - D2052M - D2053M units - - CABF cm flat cable to interconnect D2050M - D2052M - D2053M units - - CABF00 Sub D 9 Poles Female-Female Nul-Modem, 800 mm lenght for RS-232 connection - - SWC2090 Software for configuration available on our web site free of charge - - PRE-ASSEMBLED & FULLY WIRED ENCLOSURES D2000 Series GM2320-SS-08- Stainless Steel Enclosure, for installation of N D2050M Module. GM2320-SS-20- Dim.: 400x300x200 mm. With a total of N 4 M20-DN07 + N 4 M20-DN. Nichel Plated Brass Cable Glands. Note: Suitable for N - D2050M module Stainless Steel Enclosure, for installation of N D200M Module. GM2320-SS-36- Dim.: 400x300x200 mm. With a total of N 6 M20-DN07 + N 4 M20-DN. Nichel Plated Brass Cable Glands. Note: Suitable for N - D200M module Stainless Steel Enclosure, for installation of N D2030M Module. GM2330-SS-36- Dim.: 400x300x200 mm. With a total of N 32 M20-DN07 + N 4 M20-DN. Nichel Plated Brass Cable Glands. Note: Suitable for N - D2030M module Stainless Steel Enclosure, for installation of N 2 D200M or N D200M & N D20M Modules. Dim.: 600x400x200 mm. With a total of N 32 M20-DN07 + N 4 M20-DN. Nich. Plated Brass Cable Glands + 32 NB Caps. Note: Suitable for N - D2030M module or N 2 - D200M modules or N - D200M + N D20M modules GM2330-SS-52- Stainless Steel Enclosure, for instal. of N D200M & N D2030M Modules or N D200M & N 2 D20M Mod. Dim.: 600x400x200 mm. With a total of N 48 M20-DN07 + N 4 M20-DN. Nich. Plated Brass Cable Glands + 6 NB Caps. Note: Suitable for N 3 - D200M module or N - D200M + N 2 D20M modules or N - D200 + N - D2030 modules GM2330-SS-68- Stainless Steel Enclosure, for installation of N 4 D200M / D20M or N 2 D2030M Modules. Dim.: 600x400x200 mm. With a total of N 64 M20-DN07 + N 4 M20-DN. Nichel Plated Brass Cable Glands. Note: Suitable for N 2 D2030M mod. or N 4 D200M mod. or N D200M+N 3 D20M mod. or N 2 D200M+N 2 D20M mod.

11 Price List 206 ( Rev. dated March st, 206 ) Page # DSC Euro Each GMI Eq. ELCON'S ADAPTERS 000 SERIES Note: TO ORDER PLEASE SPECIFY COMPLETE ORIGINAL PART NUMBER IN EXAMPLE: "025-A AA" Analog Input, Power Supply Repeaters 0 V - ma Input / V - ma output fullly programmable V - ma Input / V - ma output fullly programmable /4W TX Supply and Repeat, Setpoint Trip Amplifier, Relay Output 2 x SPDT, Smart Tx Compatible Analog Input Repeater, Smart Tx Compatible, (non Honeywell Compatible) 25 0 Analog Input Repeater, Smart Tx Compatible, (non Honeywell Compatible) Analog Input Repeater, Floating Output Analog Input Repeater, Smart Tx Compatible G Analog Input Repeater, Smart Tx Compatible, 3 Port Isolation, Isc=93mA Analog Input Repeater, Smart Tx Compatible G Analog Input Repeater, Smart Tx Compatible, 3 Port Isolation, Isc=93mA Tx or Current Source Repeater, 2 Setpoint Trip Amplifier, Relay Output 2 x SPST, Smart Tx Compatible Analog Input Repeater, Smart Tx Compatible, Sink/Source Output, Isc=93mA Analog Input Repeater, Smart Tx Compatible, Sink/Source Output, Isc=93mA 2 25 Analog Output, Powered Isolating Drivers for I/P 03 Analog Output Repeater, Bus Powered Analog Output Repeater, Bus Powered Analog Output Repeater, Loop Powered Analog Output Repeater, Loop Powered Analog Output Repeater, Bus Powered for Smart I/P and Positioner Analog Output Repeater, Bus Powered for Smart I/P and Positioner 2 25 Anolog Signal and Temperature Converters Fully Programmable 06 TC or mv Input, Linear 4-20 ma/-5 V Output; Including C.J. Compensator TC or mv Input, Linear 4-20 ma/-5 V Output; Including C.J. Compensator TC or mv Input, Linear mv Output; Including C.J. Compensator TC or mv Input, Linear mv Output; Including C.J. Compensator RTD or Tx Pot Input, Linear 4-20 ma/-5 V Output RTD or Tx Pot Input, Linear 4-20 ma/-5 V Output RTD or Tx Pot Input, Linear 4-20 ma/-5 V Output, 3 Port Isolation RTD or Tx Pot Input, Linear 4-20 ma/-5 V Output, 3 Port Isolation Strain Gauge or Load Cell Input, 0-20/4-20 ma, 0-5/-5/0-0 V Output 25 Analog Signal and temperature Trip Amplifiers Fully Programmable 30 V/mA Input, 2 Setpoint, Relay Output, 2 x SPDT 25 3 V/mA Input, 2 Setpoint, Relay Output, 2 x SPDT TC /mv Input, 2 Setpoint, Relay Output, 2 x SPST, including Compensator TC /mv Input, 2 Setpoint, Relay Output, 2 x SPST, including Compensator RTD/Pot Input, 2 Setpoint, Relay Output, 2 x SPST RTD/Pot Input, 2 Setpoint, Relay Output, 2 x SPST Tx or Current Source Repeater, 2 Setpoint Trip Amplifier, Relay Output 2 x SPST, Smart Tx Compatible 25 Digital Input Contact-Proximity Repeater 82 Namur Prox/Contact Input Repeater, Relay Output ( x DPDT) 25 8 Namur Prox/Contact Input Repeater, Relay Output (2 x SPDT) Namur Prox/Contact Input Repeater, Transistor Output Namur Prox/Contact Input Repeater, Transistor Output Safe Area Contact Input Repeater, Relay Output ( x SPDT) Safe Area Contact Input Repeater, Relay Output (2 x SPDT) 2 25 Digital Output Drivers for Solenoid Valves, LEDs, Horns 87 Digital Output Repeater for Solenoid Valves Digital Output Repeater for Solenoid Valves Digital Output Repeater for Solenoid Valves, ONLY CODE 872-U WW (with Series D5000 Adapter) Digital Output Repeater for Solenoid Valves Digital Output Repeater for Solenoid Valves Digital Output Repeater for Solenoid Valves, ONLY CODE 874-U WW (with Series D5000 Adapter) Digital Output Repeater for Solenoid Valves Digital Output Repeater for Solenoid Valves 2 25 Note CHECK VALVE I.S. AND FUNCTIONAL PARAMETERS FOR PROPER BARRIER SELECTION D04*Q Frequency to Analog Converter + Pulse Repeater 89 Pulse Input, Prox or Mag Sensor, 4-20mA/-5 V Output, Pulse Repeater Pulse Input, Prox or Mag Sensor, 4-20mA/-5 V Output, Pulse Repeater 25

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS SHORT FORM 2002 SERIES D1000 Intrinsically Safe Galvanic Isolators SERIES D1000, for DIN Rail Mounting, provide the most simple and cost effective

More information

SIL 2/3 Relays for all applications, with or without Line & Load Diagnostics. Product presentation

SIL 2/3 Relays for all applications, with or without Line & Load Diagnostics. Product presentation SIL 2/3 for all applications, with or without Line & Load Diagnostics Product presentation Safety Safety Functions Safety Functions can be basically divided in two main groups: ETS, Energize to Safety

More information

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General

More information

Intrinsically Safe Barriers

Intrinsically Safe Barriers Intrinsically Safe Barriers Description Page No. Safety Barriers 464-472 Din Rail Isolated Barriers 473-488 477 Intrinsically Safe Barriers Product Overview We have simplified intrinsic safety! Cooper

More information

SHORT FORM INTRINSICALLY SAFE, SIL CERTIFIED INSTRUMENTATION FOR HAZARDOUS AREAS

SHORT FORM INTRINSICALLY SAFE, SIL CERTIFIED INSTRUMENTATION FOR HAZARDOUS AREAS SHORT FORM INTRINSICALLY SAFE, SIL CERTIFIED INSTRUMENTATION FOR HAZARDOUS AREAS Short Form Catalog DTS03460 COMPANY PROFILE COMPANY PROFILE Headquarter offices in Villasanta (Milan) ITALY GLISENTE LANDRINI

More information

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet Process Automation IS Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the problems associated with the

More information

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

INSTRUCTION MANUAL. SIL 2 Switch / Proximity Detector Repeater, Open Collector Output DIN-Rail and Termination Board, Model D5231E

INSTRUCTION MANUAL. SIL 2 Switch / Proximity Detector Repeater, Open Collector Output DIN-Rail and Termination Board, Model D5231E D5231E INSTRUCTION MANUAL SIL 2 Switch / Proximity Detector Repeater, Open Collector put DINRail and Termination Board, Model D5231E D5231E SIL 2 Switch/Proximity Detector Repeater, O.C. put G.M. International

More information

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications. Safety Barriers Description Safety barriers limit the energy fed to an intrinsically safe circuit so that neither sparks nor thermal effects (hot surfaces) can cause an explosion. CEAG safety barriers

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/ www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069 D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according

More information

LB Remote I/O. CEAG Sicherheitstechnik GmbH 256

LB Remote I/O. CEAG Sicherheitstechnik GmbH 256 LB Remote I/O Description LB Remote I/O modules are used as signal conditioning units between field devices and control systems. They plug into a backplane system which is mounted on a standard DIN rail.

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs Overview This document provides information relating to the use of THE BARRIER HiC2, the SMART universal barrier from Pepperl+Fuchs, a

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Introduction Honeywell s STT 3000 family of microprocessor based smart temperature

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O Engineering Guideline pac-carriers Type 995 for Honeywell system Experion Series C I/O pac-carrier Type 995 Engineering Guideline/Honeywell 04..009 pac-carrier Type 995 Integration of conventional process

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

APPLICATION GUIDE. Interface Modules IM Series.

APPLICATION GUIDE. Interface Modules IM Series. Interface Modules IM Series APPLICATION GUIDE www.turck.com Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12 0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

I/A Series HARDWARE Product Specifications

I/A Series HARDWARE Product Specifications I/A Series HARDWARE Product Specifications PSS 21H-2Y6 B4 Intrinsically Safe I/O Subsystem ISCM Base Unit for LB (Zone 2) Applications ISCM Base, Extension and Redundancy Units for FB (Zone 1) Applications

More information

Backplane. System integration. Backplane

Backplane. System integration. Backplane Backplane System integration Backplane Backplanes designed for minimum overall life cycle costs Simple, reliable and professional design Using standard cost-optimised DIN-rail devices Flexible connection

More information

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S D109S INSTRUCTION MANUAL SIL Relay Output Module with Line and diagnostics DINRail Model D109S D109 SIL Relay Output Module with Line and diagnostics ISM0096 SIL Applications For Safety Related System

More information

Backplane. Allen-Bradley. System integration. Backplane

Backplane. Allen-Bradley. System integration. Backplane Backplane System integration Allen-Bradley Backplane Backplanes designed for minimum overall life cycle costs Simple, reliable and professional design Using standard cost-optimised DIN-rail devices Flexible

More information

G.M.International Termination Boards

G.M.International Termination Boards G.M.International Termination Boards Customized and universal Termination Boards for 8/16 Units, 32/64 Channels Series D5000TB and TB-D5001-HRT G.M. International All rights reserved, also regarding any

More information

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S D5090S INSTRUCTI MANUAL 4 A Relay Output Module for NE, DIN-Rail and Termination Board, Model D5090S D5090-4 A Relay Output Module for NE G.M. International ISM09-3 Characteristics General Description:

More information

Inductive sensor BI5-EM18-Y1X-H1141

Inductive sensor BI5-EM18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Level gauges Series LS Level indicator, switch and transmitter for liquids

Level gauges Series LS Level indicator, switch and transmitter for liquids Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

MTL830 SERIES. Cuts installation and cable costs for all IS hazardous-area circuits

MTL830 SERIES. Cuts installation and cable costs for all IS hazardous-area circuits 830 SERIES Cuts installation and cable costs for all IS hazardous-area circuits Reduce the cost of installing hazardous-area cabling Save installation time, space and weight Highlight problems quickly

More information

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505 Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

APS SCALE SERIES DIMENSIONS

APS SCALE SERIES DIMENSIONS APS SCALE SERIES DIMENSIONS 4300 Section page 4 Model APS4300 Recommended Column/Base Combinations 14 Atlas Column 20 Atlas Column 30 Atlas Column Atlas Scale Series Dimensions: 4300 OPTIONS 4300 Section

More information

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mounting Corrosion resistant housing in SS316 available Selectable Units for Mass, Volume, Density

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner

More information

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i / I.S. solenoid valves, piezo and booster valves Intrinsically safe outputs Ex ia IIC Additional input for "Outputs OFF" available

More information

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Front View KEY FEATURES SIL1 / IEC 61508:2010 compliant Dual Channel Speed and Ratio Monitor with

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL

More information

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to

More information

FieldLink process networking

FieldLink process networking FieldLink process networking Enclosures Junction module (JM) StoneL s Junction Module (JM) enclosure is an environmetally hardened platform which is suitable for use in the most extreme corrosive and hazardous

More information

Adapter Kit - QSI Electronics to TM Meter Installation Instructions

Adapter Kit - QSI Electronics to TM Meter Installation Instructions Adapter Kit - QSI Electronics to TM Meter Installation Instructions These installation instructions cover the adapter kit installation of the QSI1, QSI2 and QSI3 versions of communications electronics

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

4 â Active barrier RN221N with optional HART diagnosis. Technical Information Technical Information Active barrier with optional HART diagnosis Active barrier with power supply for safe separation of 4 to 20 ma current circuits Application Galvanic isolation of 4 to 20 ma current

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

S900 Remote I/O System Intrinsic safety in the field ABB

S900 Remote I/O System Intrinsic safety in the field ABB S900 Remote I/O System Intrinsic safety in the field ABB 2 S900 REMOTE I/O SYSTEM INTRINSIC SAFETY IN THE FIELD The S900 Remote I/O System 01 Example of Field housing FH660S in stainless steel with complete

More information

S800 I/O ABB Automation

S800 I/O ABB Automation S800 I/O 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 1 S800 I/O S800 I/O 3 : Fieldbus Communication Interface (FCI) I/O Module Module Termination Unit (MTU), Compact or Extended version 3BCNIIT F HW02-S800-V0102

More information

Backplane. System integration. Backplane

Backplane. System integration. Backplane Backplane System integration Backplane Backplanes designed for minimum overall life cycle costs Simple, reliable and professional design Using standard cost-optimised DIN-rail devices Flexible connection

More information

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

General. Remote I/O A4/1.

General. Remote I/O A4/1. www.stahl.de > Intrinsically safe Ex ia IIC, Ex e, Ex na or Ex nl inputs and outputs > Fieldbus communication: Modbus RTU, Profibus DP V0 and DP V1 HART, Industrial Ethernet, Modbus TCP, EtherNet/IP, PROFINET

More information

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250 Characteristics: Features: PSS 1250 General Description: The Power Supply System type PSS1250 is an anodized aluminum 19 Rack unit (4U high) suitable to accept up to 6 plugin Power Supply Modules type

More information

Signal Conditioning Modules and Terminal Boards

Signal Conditioning Modules and Terminal Boards Signal Conditioning Modules and Terminal Boards Terminal Board Selection Guide 17-2 Isolated Signal Conditioning Modules ADAM-3000 Series Isolated Signal Conditioning Modules 17-4 ADAM-3011 ADAM-3013 ADAM-3014

More information

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D D603S D603D INSTRUCTI MANUAL SIL 3 Switch/Proximity Detector Repeater Relay, Termination Board Models D603S, D603D D603 SIL 3 Switch/Proximity Detector Repeater Relay G.M. International ISM0400 General

More information

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor with analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous

More information

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS. The LPI-LCD-6-4~20mA panel display is ideal for displaying a variety of process variables, and is easy to scale to your required engineering units. LPI-LCD-6 4~20mA Panel Display. Loop powered. Loop powered

More information

List of Components Versions for Safetec SFT-9000 systems

List of Components Versions for Safetec SFT-9000 systems SAFETEC srl Certificate No.: 01/205/5591.00/17 Table 1a: SIL3-Certified HW Components Report-Number ST DIN-10 DIN-1007.00-XXXX ST DIN-11 DIN-1107.00-XXXX safety digital input card, 2x12 NAMUR inputs safety

More information

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE In times where energy conservation is a top priority for all progressive enterprises, the measurement of flow rates and consumption is becoming more and

More information

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250 PSS 1250 Characteristics: General Description: The Power Supply System type PSS1250 is an anodized aluminum 19 Rack unit (4U high) suitable to accept up to 6 plugin Power Supply Modules type and 1 Overview

More information

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mounting Corrosion resistant housing in SS316 available Selectable Units for Mass, Volume, Density

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

SWC1090 configuration software for G.M. International Isolators series D1000 and E1000. Installation and use manual

SWC1090 configuration software for G.M. International Isolators series D1000 and E1000. Installation and use manual SWC1090 configuration software for G.M. International Isolators series D1000 and E1000 Installation and use manual ISM0084-2 Installation and use of the SWC1090 calibration software Page 1 of 12 Index

More information

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3. Line A Inverse parallel scrs Load a Line B FUSION SCR POWER O delta CONTROLLERS Line c inverse parallel scrs Load C FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC or DC Output AC Models: 50-1200

More information

MULTICHANNEL DATA RECORDERS

MULTICHANNEL DATA RECORDERS MULTICHANNEL DATA RECORDERS Introduction ma + V / mv RTD + - universal inputs + - TC universal inputs: RTD + TC or U + I (SRD-99) fixed inputs: RTD, TC, U, I (SRD-N16) 2 relay outputs memory up to 3 000

More information

Digital electropneumatic Positioner SideControl

Digital electropneumatic Positioner SideControl Digital electropneumatic Positioner SideControl Type 8791 BASIC can be combined with Compact and robust design Easy to start using tune function Dynamic positioning system with no air consumption in controlled

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

-Camille Bauer Div. of Absolute Process Instruments, Inc. Phone: Fax: J-1

-Camille Bauer Div. of Absolute Process Instruments, Inc. Phone: Fax: J-1 Solving Your Y Application Challenges! Phone: 800-462-4040 Fax: 800-949-7502 www.apicb.com 1220 American Way Libertyville, IL 60048 USA Copyright Absolute Process Instruments, Inc. 02/03 CBSK2003A J-1

More information

Discrete I/O connected direct onto. Input and Output Function Blocks. Two built-in Solid State Relay Outputs. Discrete Function Blocks in the field

Discrete I/O connected direct onto. Input and Output Function Blocks. Two built-in Solid State Relay Outputs. Discrete Function Blocks in the field Discrete I/O connected direct onto Profibus-PA Input and Output Function Blocks Two built-in Solid State Relay Outputs Discrete Function Blocks in the field Integrated I/O on the same hardware Two dry

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications. EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier

More information

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller /

More information

M-series Intrinsically Safe I/O

M-series Intrinsically Safe I/O DeltaV Distributed Control System Product Data Sheet M-series Intrinsically Safe I/O Features full system modularity Reduces system footprint Decreases installation time and expense Plug-and-play installation

More information

Adapter Kit - QSI Electronics to G2 Meter Installation Instructions

Adapter Kit - QSI Electronics to G2 Meter Installation Instructions Adapter Kit - QSI Electronics to G2 Meter Installation Instructions These installation instructions cover the adapter kit installation of the QSI1, QSI2 and QSI3 versions of communications electronics

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Universal Safety IO System board for Honeywell Universal Process IO For 6-channel cards USIO and UPIO For 6 modules Recommended modules: HiC8R (DI), HiC85R

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

Signal conditioners with Functional Safety The MACX ranges

Signal conditioners with Functional Safety The MACX ranges Signal conditioners with Functional Safety The MACX ranges Reliable and safe MACX signal conditioners Maximum safety for your systems and machines: in all phases of the product lifecycle, MACX signal conditioners

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof

More information

Relays SAFETY RELAYS SERIES. High Integrity Safety Relays. Suitable for SIL 3 applications according to IEC and IEC D5000 / D1000 SERIES

Relays SAFETY RELAYS SERIES. High Integrity Safety Relays. Suitable for SIL 3 applications according to IEC and IEC D5000 / D1000 SERIES D5000 / D1000 SERIES SFETY RELYS SERIES High Integrity Safety Relays Suitable for applications according to IEC 61508 and IEC 61511 Relays technology for safety DTS0262-1 27 SFETY RELY - FETURES SFETY

More information

IHP24. Intelligent Hydraulic Positioner D HP- PL

IHP24. Intelligent Hydraulic Positioner D HP- PL IHP24 Intelligent Hydraulic Positioner D HP- PL- 0 0 3-01 IHP24 Intelligent Hydraulic Positioner Val Controls A/S Intelligent valve control based on the latest know-how concerning digital technology for

More information

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018 September 2018 Module Status LED Channel Status LEDs Digital Input Connector Ground 24 V DC FE Analog Input Module RSTI-EP Slice I/O Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664,

More information