2100-IS RS232 to RS422\485 Converter.

Size: px
Start display at page:

Download "2100-IS RS232 to RS422\485 Converter."

Transcription

1 to RS\8 Converter. Converts and Isolates from a computer to RS or RS8 for communication to a field Datalogging system. REGI STERED ISO001 S U P P I L R E 1 TECHNOLOGY & QUALITY AWARD Features. l Audible & Relay Alarms for Communication Failure. l Easy to Install. l LED Status Indications. l Compact Desk Top Box. l Low Cost. l Selectable Alarm Time Delays. l Isolation Between Field Units & Computer. l Complete With Serial Cable & 2m Power Cord. Ordering Information. Standard Unit: Accessories: 00-IRT 00-IRG 00-IM 00-IP 00-IB Isolated to Convertor. Other 00 models include: 00-A16 :16AI, DI, 2 Relay Out; 00-A :AI, DI, Relay Out; 00-Ae :AI, DI, 8 Relay Out; 00-D :12DI, 12 Relay Out; 00-ME :Memory Expansion for 00-A; 00-M :16AI Multiplexer; 00-NS :Non-Isolated to RS; 00-R :16 Relay Expansion for 00-A. Adaptor Kit for Tait TA8 RF Radio Modem. Adaptor Kit for Gigatek RDL-201 RF Radio Modem. Adaptor Kit for Standard Telephone Modem. Cable for Parallel Connection of up to Four Convertors. Adaptor Kit for Boosting. Description. The is a compact, desktop module that isolates and converts from a computer to RS or RS8 for communication to a field data logging system. Its driver and receiver meet EIA standards RS--A and CCITT recommendations V.11 and X.27, and are designed for multipoint transmission on long bus lines in noisy environments. It includes thermal shutdown and over current limiting. The includes audible and fail safe alarms of communications failure, with selectable time delays. It is capable of interfacing to telephone modems, and RF modems. Its internal mains supply powers both sides of the isolation barrier, making it suitable for working with many types of PCs and PLCs. It comes complete with a 2m cable with a selection of either a way or 2 way connector for the PC. Front View Quality Assurance Programme. The modern technology and strict procedures of the ISO001 Quality Assurance Programme applied during design, development, production and final inspection grant long term reliability of the instrument. This instrument has been designed and built to comply with EMC and Safety Standards requirements

2 Installation Guide Index. Description and Ordering Information page 1 Specifications, LED Functions, Alarm Description. page 2 Circuit Board Layout, Switch Functions. page RS and RS8 Serial Connections. page Data Cable Installations. page and Booster. Modem Connections. page 6 Multiple Parallel. DB2 Pinout. page 7 Commissioning and Maintenance page 8 Specifications. Comms Baud Rate -Standard 600baud. -Optional 800 or 1200baud. Comms Input / Output Isolation 1.0kV ac/dc for 1min. Power Supply 20/11Vac±10%, 0/100mA, 0/60Hz. EMC Emissions Compliance EN 0-A EMC Immunity Compliance EN Safety Compliance. EN 600 Operating Temperature Storage Temperature Operating Humidity Housing Dimensions Weight Alarm Relay 0~60C. -20~80C. 0%RH Max. Non-Condensing. Desk Top Metal Box. L=10, W=11, H=8. 100g. (Includes Cables.) 2Vdc Max. Note 1. Specifications based on Standard Calibration Unit, unless otherwise specified. Note 2. Due to ongoing research and development, designs, specifications, and documentation are subject to change without notification. No liability will be accepted for errors, omissions or amendments to this specification.! CAUTI: Dangerous voltages may be present. The has no user serviceable parts. Protective enclosure only to be opened by qualified personnel. Remove ALL power sources before removing protective cover. Description of LED Functions. R.X. LED Unit Receiving Data From the Field. T.X. LED Unit Transmitting Data to the Field. T.X.E. LED Transmit Enable Line Active. ALARM LED Unit in Alarm. PWR LED Unit has Power Connected. RESET Switch Push this Switch to Reset the Alarm. This does not reset the computer. (See Description of Alarm Function). Description of Alarm Function. Note: In the description below we have selected an alarm time delay of minutes, Audible is active, Relay is active, and Time Out is active. After approx. minutes of the last RX data having been received the audible, relay and LED alarms activate. If more RX data is received after the unit has gone into alarm the alarms remain active until the RESET button is pushed. (1) When the RESET button is pushed the audible, relay and LED alarms reset. (2) If after approx. 1 hour of the RESET button being pushed no data has been received the alarm 'times out', and the audible, relay and LED alarms reactivate Notes: (1) To deactivate the audible alarm only, place S1-6. (2) To deactivate all audible, relay and LED alarms, place all S1 switches OFF. () To deactivate the 1 hour time out function, place S2-6 OFF

3 Circuit Board Layout. MINS: A.D AUTO RTS T.O. Relay V 11V Neut. Earth N.C. N.O. COM COM RX+ RX- TX+ TX- RAD STD H2 S1 Selectable Alarm Time Delays. 6 Way DIP Switch DIP Switch 1 -Turn on for: minute Alarm Time Delay. 2 -Turn on for: 7 1/2 minute Alarm Time Delay. -Turn on for: 0 minute Alarm Time Delay. -Turn on for: 1 hour Alarm Time Delay. -Turn on for: 2 hour Alarm Time Delay. 6 -Turn on to Disable the Audible Alarm. Notes 1/ Only 1 of DIP switches 1 to should be on at any one time. 2/ To disable all the alarms put all S1 DIP switches OFF. / All alarm time delays are approximate only. S2 Description of Switch Settings. 6 Way DIP Switch Notes 1/ 1 - connects TX to RX. 2 - connects TX to RX. - = RX automatic. OFF = RX permanently. - = TXE 20ms automatic switch OFF. - = TXE under RTS control. 6 - = alarm 1 hour time out. Only 1 of DIP switches and should be on at any one time. /8 Mode Settings. 6 Way DIP Switch Mode Settings. -Microscan 8-Microscan 8-RTS Control 1 OFF 2 OFF OFF OFF OFF OFF OFF 6 Refer to descriptionof alarm function

4 OUTSTATI LAYOUT. 2-Wire RS8 Serial Connections. ; PLC = = OFF S2-6 Position refer page. 00-A 00-A16 00-D DATA HI-WAY CABLE POLARITY MUST BE OBSERVED COM TX+ TX- to RS\8 CVERTOR \ ISOLATOR. 1 Shimaden SD20 with RS8 option. 2 Shimaden SR/ with RS8 option. 2 1 Shimaden SR7A/A with RS8 option. To other INTECH MICRO Remote Stations & Shimaden Controllers etc. IMPORTANT: (i) Resistor = 1kΩ. End of Data Hi-way Junction Box. DATA HI-WAY All cables must be screened. (ii) All screens must be connected together. (iii) The screen must not be earthed at any point. Notes: (i) RS8 can only be used with software release IQ onwards. (ii) RS8 Data Hi-way is not compatible with RS Data Hi-way devices such as IN-2000-AI, IN-2000-AO, IN-2000-DI, IN DO, FP, SR2, etc. The two Data Hi-ways must be run independent of each other, using two separate ', that share the same. Refer to parallel connection of into multiple ', on page 7. IMPORTANT: (i) All cables must be screened. (ii) All screens must be connected together. (iii) The screen must not be earthed at any point. Shimaden SR2 with RS8 option OUTSTATI LAYOUT. -Wire RS Serial Connections. PLC; S2:Factory set S2-6 Position refer page. OFF 00-A16 00-A 00-D 20 2 IN-2000-AI IN-2000-AO IN-2000-DI COM RX+ RX- TX+ TX IN-2000-DO to RS\8 CVERTOR \ ISOLATOR. DATA HI-WAY CABLE. POLARITY MUST BE OBSERVED To other INTECH MICRO Remote Stations & Shimaden Controllers etc. Resistors = 1kΩ. End of Data Hi-way Junction Box. 6 Shimaden FP Shimaden SD20 6 Shimaden SR2 6 Shimaden SR Shimaden SR/ 2 1 Shimaden SR7A/A IMPORTANT: (i) All cables must be screened. (ii) All screens must be connected together. (iii) The screen must not be earthed at any point.

5 00 SCADA. Data Cabling Installation eg 1. Data Cabling Installation eg 2. Terminating Resistors at Cable End. <0m <0m RS (e.g. 00-D) RS (e.g. Shimaden SR7) to CVERTOR MAY BE PLACED ANYWHERE ALG DATA HI-WAY. RS (e.g. 00-A16) <0m <0m >0m RS (e.g. 00-A) RS (e.g. 00-D) RS (e.g. Shimaden SR7) Terminating Resistors at Cable End. <0m >0m RS (e.g. Shimaden SR7) Note: RS = MICRO 2000 or 00 Remote Stations, or SHIMADEN CTROLLERS. IMPORTANT: The accompanying Installation Instructions must be strictly adhered to. Terminating Resistors at Cable End. Terminations for all Models of / 00-NS / IN-2000-IS. Model RS Alarm Mains (RS8) Relay Supply Terminations 00-NS IN-2000-IS Rev. 2 IN-2000-IS Rev.0, Rev. 1 Term No Connection Term No Connection Term No Connection Term No Connection 20Vac 1 Phase(2~20Vac) 1 20Vac 2 11Va c 2 Neutra l 2 11Va c 1 Neutra l Earth Neutra l 0 Earth Earth Earth 62 N.C. N.C. N.C. 61 N.O. 6 N.O. 6 N.O. 60 COM 7 COM 7 COM 7 Vdc, 200mA 8 0V 8 0V COM COM RX+ RX+ 7 RX+ 7 RX+ 10 RX- 10 RX- RX- RX- 11 0V 11 0V TX+ (RS8) TX+ 12 TX+ 12 TX+ TX- (RS8) TX- 1 TX- 1 TX

6 Booster Connection Diagram. Where the is required to exceed it's specified cable length of 1m, two or more ' can be used to extend the signal up to 1200m. (To extend further refer to the following section, using the 00-IB Booster Adapter.) Note. (1) This cannot be used for hardware handshaking. (2) PLC to use pin ( RTS) multidrop operation. Set S2- ''. RS RS ; PLC 1 Note 2. RS ; etc PLC 2 Note 2. Booster Connection Diagram. Where the Data Hi-way exceeds 1200m it is necessary to boost the signal. end of trunk line. 00-IB Adapter kit. Standard Cable supplied with. boosted signal. Note: Detailed connection information supplied with 00-IB Adapter Kit. Modem Connection Diagrams. Tait TA8 RF modem connection. Remote station. Standard Cable supplied with. H2 link in 'RAD' position. 00-IRT Adapter kit. Radio Gigatek RDL-201 RF modem connection. Remote station. Standard Cable supplied with. H2 link in 'RAD' position. 00-IRG Adapter kit. Radio Standard modem connection. Remote station. Standard Cable supplied with. H2 link in 'STD' position. 00-IM Adapter kit. Note: Detailed connection information supplied with each 00 Modem Adapter Kit Modem

7 Parallel Connection of to Multiple '. Used in situations where the Data Hi-way is going in different directions in a plant. Up to six ' can be connected in this configuration. Note: If the overall Data Hi-way does not exceed 1200m, one should be sufficient. COMPUTER / CTROL ROOM. Note 1.. Note 2. not to exceed 1m. Note. data hi-way 1 data hi-way 2 data hi-way Area 1 Area 2 Area Note. (1) Cable supplied with. (2) 00-IP cable for parallel connection of up to four convertors. () For connection of more than four ', two 00-IP cables can be connected together. () This mode is not to be confused with the interfaces "Dual Port Mode" which is used to access more than 2 Shimaden Controllers on two serial ports. () To parallel a with an IN-2000-IS remove any links from H2 on the. Pinout of DB2 Connector. = DCE. (Data Communications Equipment.) Pin Name TD RD RTS CTS SG DSR CD DTR RI Signal Name Transmitted Data Received Data Request to Send Clear to Send ignal Ground DB2 Connector D irection Pin No. H2 STD In 2 TX Out RX In TXE Out CTS H2 RAD TX RX TXE Radio CTS H2 Open TX RX TXE N/ C 0 S - 7 0V 0V V Data Ready to Send Carrier Detect Data Terminal Ready Ring Indicator In 6 Out 8 Out 20 N/ C N/ C linked linked N/ C linked N/ C linked Note: For position of header H2 refer to Circuit Board Diagram, page

8 The Proper Installation & Wiring of the. MOUNTING. (1) Mount in a clean environment. (2) Do not subject to vibration, excess temperature or humidity variations. () Avoid mounting near power control equipment. ANALOGUE SIGNAL CABLING. (1) All analogue cables should be good quality, overall screened, INSTRUMENTATI CABLE, with the screen earthed at one end only. (e.g. Austral Standard Cables B102ES.) (2) Analogue signal cables should be laid a minimum distance of 00mm from power and data cables. () It is recommended that you do not ground current loops or use power supplies with ungrounded outputs. () Lightning arresters should be used on inputs and outputs when there is a danger from this source. () Refer to diagrams for connection details. COMMS CABLING. (1) Use only low capacitance, twisted pair, overall screened data cable. The cable must equal or better the following specifications. Cable Specifications. Conductor Size. 7/0.20mm, 2AWG Conductor 20C. 8. Ω/100m Max. Working Voltage. 00Vrms Capacitance between wires of a pair. 0ρF/ m Capacitance between each wire to all others bunched together. ρf/ m Cross-talk between 100kHz >-0dB/100m >-0dB/100m Characteristic 100kHz 1Ω Attenuation of a 1.MHz 0.1dB/100m 0.2dB/100m 0.8dB/100m 0.dB/100m 1.dB/100m 2.dB/100m NOTE: All cables are to be subject during manufacture to in-process spark kvrms. All cables are to be tested between conductors and conductors to screen for 100Vrms. (2) Minimum cable pairs: RS = 2. (Plus overall screen.) RS8 = 1. (Plus overall screen.) () Take care not to stress or damage cables during installation. () Total length of trunk line, including spurs, is not to exceed 1200m without isolating boosters. () Terminating resistors -1kΩ. (6) Cabling paths should avoid sources of radio frequency interferences such as fluorescent lights, variable speed motor drives, welding equipment, radio transmitters, etc. (7) There should be a minimum of 200mm physical separation between power cables and data cables. (8) Data cables should not be exposed to excessive heat or moisture, and should not be buried directly in the ground without protection. () Avoid powering a remote station or controller from the same power supply as a variable speed drive. P.O. Box 60, Thompson Ridge, NY VESPO VESPO ( ax) Website: E mail: controls@vespo.com

INTECH Micro 2100-IS Rev 1.1.

INTECH Micro 2100-IS Rev 1.1. INTECH Micro Rev 1.1. REG ISTERED ISO9001 MANU CTURER F A TECHNOLOGY & QUALITY AWAR D Z985 Installation Guide. 14.05-1 Section A. Description, Ordering and Specifications. Installation Guide Index. Section

More information

INTECH Micro 2100-NET

INTECH Micro 2100-NET INTECH Micro REG ISTERED ISO9001 MANU CTURER F A TECHNOLOGY & QUALITY AWAR D Z985 Installation Guide. 14.12-1 Section A. Description, Ordering and Specifications. Installation Guide Index. Section A. Description,

More information

Z-2400-RB/TCP TURBO Wireless Data Links Using ZIGBEE For MicroScan Protocols.

Z-2400-RB/TCP TURBO Wireless Data Links Using ZIGBEE For MicroScan Protocols. Z-2400-RB/TCP TURBO Wireless Data Links Using ZIGBEE For MicroScan Protocols. Installation Guide. Z-2400-Base/Remote Turbo Installation Guide Index: Description. Page 3 Ordering Information. Page 3 Specifications.

More information

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RO4 Installation Guide. The 2300 series stations are designed to

More information

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to

More information

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RTD6 Installation Guide. The 2300 series stations are designed to

More information

Intech Micro 2400-A16

Intech Micro 2400-A16 Intech Micro 2400A16 Installation Guide. 2400A16 Installation Guide Index. Features. Page 4 Product Liability. Page 4 Description. Page 4 Ordering Information. Page 5 Ordering Examples. Page 5 2400A16

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS Serial Communications Accessories SITRANS RD200/300 Operating Instructions 05/2013 SITRANS Siemens Auto SIT SITRANS RD300RANS RD300 Safety Guidelines: Warning notices must be observed to ensure personal

More information

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems Interface converter for RS- to transmission systems. Short Description The rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

Thermocouple Input Module Product Specifications and Installation Data

Thermocouple Input Module Product Specifications and Installation Data Thermocouple Input Module Product Specifications and Installation Data 1 DESCRIPTION The Horner APG Thermocouple Input Modules allow thermocouple temperature sensors to be directly connected to the PLC

More information

EA500. Installation Instructions Transponder

EA500. Installation Instructions Transponder EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3 INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

ISOLATED RS-232 TO RS-422/485 CONVERTER

ISOLATED RS-232 TO RS-422/485 CONVERTER QUICK START GUIDE ICD400A ISOLATED RS-232 TO RS-422/485 CONVERTER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Specifications Complies with FCC Class B and CE requirements. Withstands

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 Manual PCD3.C90 Revision History Date Modification Asked by: Version 14.09.09 E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 22.09.09 Added E/A Bus Connector PCD3.K116 Müller.R 1.2 06.01.10

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

RTU32. Installation and wiring manual. Utility Outstation and Controller. Doc No Version 3.00

RTU32. Installation and wiring manual. Utility Outstation and Controller. Doc No Version 3.00 Utility Outstation and Controller Installation and wiring manual Doc No 40215 Version 3.00 Regulations for the installation and operation of electrical systems The RTU32 devices are produced under the

More information

Voltage Transducer UMT516 / MT516

Voltage Transducer UMT516 / MT516 Voltage Transducer UMT516 / MT516 True RMS AC voltage measurements Voltage auto range measurements up to 600V # Wide frequency measurement range 16 400 Hz High accuracy class 0.2 (IEC-688), 0.1 on communication

More information

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter ICD105A 1008 page 1/5 7319 r001 ICD105A Industrial RS-232 to RS-422/485 Converter Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

MEV Limited USB232/485 INSTRUCTION MANUAL

MEV Limited USB232/485 INSTRUCTION MANUAL MEV Limited USB232/485 INSTRUCTION MANUAL USB TO RS232 / RS485 SERIAL COMMUNICATIONS INTERFACE WITH ISOLATION OPTION Issue 5 LIST OF CONTENTS 1 INTRODUCTION 1 1.1 The Products Described in this Manual

More information

Multifunction Transducer MT440

Multifunction Transducer MT440 Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up

More information

Media Converters. Media Converters. Product Selection Guides

Media Converters. Media Converters. Product Selection Guides Product Selection Guides Media Converters Serial-to-Fiber Converter Selection Guide....................................-2 Serial-to-Serial Converter Selection Guide...................................-3

More information

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.

More information

IQ21x Series Controllers

IQ21x Series Controllers IQ1x Series Controllers IQ1x SERIES CONTROLLERS Description Features The IQ1x series of intelligent controllers are designed for use as unitary controllers in building control systems. Full compatibility

More information

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector Gigabit Ethernet Switch with PoE+ for Industrial Use Page 2/11 Table of Contents General... 3 Benefits... 3 Front View...

More information

MED102A. Industrial Serial to Single-mode Fiber Converter

MED102A. Industrial Serial to Single-mode Fiber Converter MED102A - 0708 pg. 1 / 5 MED102A Industrial Serial to Single-mode Fiber Converter Data Rates up to 115.2 kbps 9 Mile (15 km) Range 10 to 48 VDC Input Voltage Wide Operating Temperature 2000V Isolation

More information

Koppelmodul (HART--Modem) für SIMATIC PDM Interface (HART modem) for SIMATIC PDM

Koppelmodul (HART--Modem) für SIMATIC PDM Interface (HART modem) for SIMATIC PDM Koppelmodul (HART--Modem) für SIMATIC PDM Interface (HART modem) for SIMATIC PDM 7MF4997--1DA Ausgabe Februar 2002 Edition February 2002 C73000--B7164--C170--2 1 /16 Koppelmodul für SIMATIC PDM Interface

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

Sauter Systems

Sauter Systems 96.692/1 EYZ 292:, interface The is a interface for connecting the CASE Suite/ programming tools and the various novapro software on the management level to the EY3600 system with in a local area network

More information

Manual Industry Interfaces

Manual Industry Interfaces Manual Industry Interfaces W&T Release. Type 0, 0 0, 00 0, 0 0, 0 Industry Interfaces 0/0 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make mistakes, none of our statements should

More information

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide Industrial Serial RS-232 to Fiber Converter KSC-200 Series Installation Guide DOC.100803-KSC-200-1- (C) 2006 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any

More information

modunet292: novanet-ethernet interface

modunet292: novanet-ethernet interface SAUTER EY-modulo 2 PDS 96.015 en Product Data Sheet EY-BU292 : - interface How energy efficiency is improved SAUTER EY-modulo 2 integrated into familiar IP technology Areas of application Parameterisation

More information

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 05/2009 MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES.

More information

iologik E1200H Series

iologik E1200H Series iologik E1200H Series Ethernet remote I/O for offshore wind power applications Features and Benefits User-definable Modbus TCP Slave addressing 2-port Ethernet switch for daisy-chain topologies Active

More information

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types Millenium 3 General Characteristics Millenium 3 Compact Range Millenium 3 Expandable Range Millenium 3 Communication Options Millenium 3 Range General environment characteristics for CB, CD, XD, XR and

More information

Z-2400-SERIES Wireless Data Links Using ZIGBEE For MicroScan Protocols

Z-2400-SERIES Wireless Data Links Using ZIGBEE For MicroScan Protocols Z-2400-SERIES Wireless Data Links Using ZIGBEE For MicroScan Protocols Installation Guide Z-2400-RB Installation Guide Index Description Page 3 Specifications Page 3 Ordering Information Page 3 Physical

More information

DATA CONNECT ENTERPRISE

DATA CONNECT ENTERPRISE DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

EY-EM : Remote I/O module, ecolink

EY-EM : Remote I/O module, ecolink EY-EM 510...512: Remote I/O module, ecolink510...512 How energy efficiency is improved Optimum adjustment to applications by means of module technology. Reduction in wiring Features Part of the SAUTER

More information

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU) Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU) Rev. 2 September 2012 Part No. 4417552 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax :

More information

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX Entry Line Fast Ethernet Switch Fast Ethernet Switch for Industrial Use Page 2/11 Table of Contents General... 3 Benefits... 3 Front

More information

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China. FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection

More information

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M USB to Optical Adapter Industrial Isolated RS- 232/422/485 Product Manual Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M 2 USB-COMi-SI-M Product Manual Revision History Revision Date

More information

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION TECHNICAL DESCRIPTION SPECIFICATIONS... 14

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION TECHNICAL DESCRIPTION SPECIFICATIONS... 14 Contents INTRODUCTION...1 OVERVIEW...1 WHAT S INCLUDED...1 FACTORY DEFAULT SETTINGS...1 CARD SETUP...2 ADDRESS SELECTION...2 IRQ SELECTION...3 INTERRUPT MODES...4 RS-485 ENABLE MODES...5 CONNECTOR PIN

More information

RS-232 Industrial Media Converter

RS-232 Industrial Media Converter USER GUIDE The leader in rugged fiber optic technology. U-151 2018C-0327 Industrial Media Converter COMPACT, RUGGED & TEMPERATURE HARDENED Introduction This Industrial Serial Data media converter transports

More information

Channel Switch CS. General Operating, Maintenance and Installation Manual

Channel Switch CS. General Operating, Maintenance and Installation Manual Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V130 COM Modules: V100-17-CAN, V100-17-RS4/X, V100-17-ET2 This guide shows you how to install an additional communication module in a V130 controller. Instructions and technical specifications

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

Moxa TCC-100 Series Hardware Installation Guide

Moxa TCC-100 Series Hardware Installation Guide Moxa TCC-100 Series Hardware Installation Guide Twelfth Edition, January 2015 www.moxa.com/product 2015 Moxa Inc. All rights reserved. P/N: 1802001000319 Moxa TCC-100 Series Hardware Installation Guide

More information

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual page 2 of 15 Contents: Overview... 2 Models... 3 Power... 4 Probes... 4 Connector identification... 5 Pin-out diagrams... 6

More information

XT-9100 Technical Bulletin

XT-9100 Technical Bulletin System 9100 Technical Manual 636.4 Technical Bulletins Section Technical Bulletin Issue Date 0896 XT-9100 Technical Bulletin XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3 SX

More information

This guide provides basic information for Unitronics controllers V C30B and V T40B.

This guide provides basic information for Unitronics controllers V C30B and V T40B. Vision OPLC V570-57-C30B and V570-57-T40B (Color) This guide provides basic information for Unitronics controllers V570-57-C30B and V570-57-T40B. General Description Vision OPLCs are programmable logic

More information

APP 700 Technical Specification

APP 700 Technical Specification Issued: 12/12 Supersedes: 4/12 Description The APP 700 hardware series are especially designed for waste and clean water systems, both in construction and functionality. The RTUs¹ are developed to meet

More information

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

MODEL USB-FLEXCOM4. USB to Four RS-232/422/485 Serial Ports and MODEL USB-COM232-4A USB to Four RS-232 Serial Ports USER MANUAL

MODEL USB-FLEXCOM4. USB to Four RS-232/422/485 Serial Ports and MODEL USB-COM232-4A USB to Four RS-232 Serial Ports USER MANUAL Embedded Solutions MODEL USB-FLEXCOM4 USB to Four RS-232/422/485 Serial Ports and MODEL USB-COM232-4A USB to Four RS-232 Serial Ports USER MANUAL FILE: MUSB-FLEXCOM4.B1f ADL Embedded Solutions GmbH, Eiserfelder

More information

Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS

Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS SWH Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS Rev.1 01/03/2013 1. Overview The SWH is a complete board Cellular Terminal solution for GSM GPS/GLONASS applications.

More information

GT- IRDM-9603 Product description Rev. 2 17/06/2014

GT- IRDM-9603 Product description Rev. 2 17/06/2014 GT- IRDM-9603 Product description Rev. 2 17/06/2014 1 1. Overview The GT- IRDM- 9603 is a complete Satellite Terminal solution for Satellite applications. Based on IRIDIUM 9603 module. 2. Hardware Interface

More information

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company Data Sheet SRM-3A Ultra-Miniature Isolated Short-Range Async Modem The Access Company Features Asynchronous transmission of up to 19.2 kbps Transmission range of up to 13 km (8 miles) Ultra-miniature modem

More information

FEATURES DESCRIPTION FEATURES

FEATURES DESCRIPTION FEATURES FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs 24 Sinking or Sourcing Inputs 16 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate

More information

Quick Start Guide. Installation. User s Manual 1

Quick Start Guide. Installation.  User s Manual 1 Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. This is the Hardened Ethernet Extender of choice for harsh environments constrained by space. Installation

More information

SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21

SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21 SSW7 Adapter for MPI-Bus 700-751-1VK21 User Manual Version:2 / 2009-03-20 HW: 1 / FW: 3.0 and higher Order number of manual: 700-751-1VK21/en Systeme Helmholz GmbH Hannberger Weg 2 D-91091 Großenseebach

More information

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual 5915 SDI-12 Interface Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:

More information

SX90 Process Controller

SX90 Process Controller Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications UC-7100 Series Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports Features and Benefits MOXA ART Arm9 32-bit 192 MHz processor 16 or 32 MB RAM 8 or 16 MB Flash ROM Dual or single

More information

RS-232 Fiber Link Card System

RS-232 Fiber Link Card System USER GUIDE The leader in rugged fiber optic technology. U-152 2018B-0406 Fiber Link Card System SYSTEM INSTALLATION INFORMATION Introduction The Fiber Link Card system transports a full 9-Pin copper signal

More information

Features and Benefits. Certifications

Features and Benefits. Certifications iologik R1200 Series RS-485 remote I/O Features and Benefits Dual RS-485 remote I/O with built-in repeater Supports the installation of multidrop communications parameters Install communications parameters

More information

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration Manual Universal FO Interface Converter Model 81215 Release 1.0 Subject to error and alteration 13 10/2012 by Wiesemann & Theis GmbH Subject to error and alteration: Since it is possible that we make mistakes,

More information

TCNM-ACBB1 Installation Manual

TCNM-ACBB1 Installation Manual The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is

More information

EZ864 UMTS Terminal Telit Cellular GSM Engine

EZ864 UMTS Terminal Telit Cellular GSM Engine EZ864 UMTS Terminal Telit Cellular GSM Engine Version: 01.01 EZ864 UMTS Terminal_HD_V01.01 06.Mar.2008-1 - Hardware Interface Description 1. Hardware Features of the EZ864 UMTS Terminal Feature Implementation

More information

Temperature Controller

Temperature Controller 2 728 Temperature Controller ultizone Floor Heating Systems RRV817 ultizone model with up to 7 zone outputs by combining 2 RRV817 controllers. Used for central control of underfloor heating systems in

More information

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd PRODUCT MANUAL Power Supply Westell Technologies. 960-1152-MNL rd DISCLAIMER All information and statements contained herein are accurate to the best of Westell Technologies knowledge. Westell Technologies

More information

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function Appendix A Specifications This appendix lists the specifications for the BANDIT family of products. Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200

More information

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ. Vision OPLC V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ. General Description V1210 OPLCs are programmable logic controllers that comprise a built-in operating

More information

AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC REPEATER. USER GUIDE Doc. ref : Distribué par : Contact :

AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC REPEATER. USER GUIDE Doc. ref : Distribué par : Contact : Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Siège social : 2 rue René Laennec 51500 Taissy France www.hvssystem.com AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC

More information

Serial Data DIN Fiber Link System

Serial Data DIN Fiber Link System USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-120 2017A-0420 DIN Fiber Link System COMPACT, RUGGED & TEMPERATURE HARDENED Introduction The DIN Fiber Link system transports

More information

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1 TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT NOTICE... 2 PRODUCT CONFORMITY... 3 WARRANTY AND SAFETY INSTRUCTIONS... 4 1 GENERAL... 5 1.1 SATEL I-LINK 100 MODBUS I/O- CONVERTER... 5 2 SPECIFICATIONS...

More information

High Performance Output Filter Instruction Manual

High Performance Output Filter Instruction Manual High Performance Output Filter Instruction Manual R TECHNOLOGY AND QUALITY ASSURANCE Since 1976 Zener Electric has supplied many thousands of drives to industry. These drives have been installed into numerous

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

CS485. User s Manual. Version ZYPEX, Inc.

CS485. User s Manual. Version ZYPEX, Inc. CS485 User s Manual Version 2.0 2003 ZYPEX, Inc. Table of Contents Product Description 1 CS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter

More information

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions 3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface DESCRIPTION The modems are a series of general-purpose industrial modems, which can be used for data communication through Public Switched Telephone Networks (PSTN). The modems can operate in 2-wire, full-duplex,

More information

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 TOSHIBA Corporation 2004 All Rights Reserved. ( Ver. 1.6 ) Safety Precautions Before using this product, please read this chapter carefully. This

More information

1. Safety Precautions (Read these precautions before use.)

1. Safety Precautions (Read these precautions before use.) R P5102S/N/N1 HMI Installation Guide Thank you for purchasing FATEK HMI. Before installing or operating the unit, please read this installation guide carefully to ensure correct use. 1. Safety Precautions

More information

LLR-MOD Modbus Light Level and Occupancy Sensor

LLR-MOD Modbus Light Level and Occupancy Sensor Product sheet SN1.418 Type LLR-MOD LLR-MOD Modbus Light Level and Occupancy Sensor The LLR-MOD sensors are designed to measure Light Level (LUX) in the room spaces and have built-in RS485 Modbus communication

More information

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel

More information

COM32. Installation & Operation Manual

COM32. Installation & Operation Manual COM32 Installation & Operation Manual DANGER ElectricaI equipment contains hazardous voltages and high speed moving parts. Can cause death, serious injury or property damage. See safety instruction contained

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET Measurement input, auto range Up to 1000 V AC L-L Up to 12.5 A (sinusoidal) 16 400 Hz Output Up to four analogue outputs Relay output RS 485 Modbus

More information

AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine

AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine Version: 01.01 AQ_G24 Terminal Card_HD_V01.01 17.JUL.2008-1 - Hardware Interface Description 1. Hardware Features of the AQ_G24 Terminal Card Feature

More information

Installation & Configuration manual. InduBox GSM IV

Installation & Configuration manual. InduBox GSM IV Installation & Configuration manual InduBox GSM IV 2008 / 02 / 19 2 ! CAUTION! ELECTRIC SHOCK HAZARD IF COVER REMOVED SERVICE BY QUALIFIED PERSONEL ONLY Document History Date Version Auteur 02/10/2006

More information

MGate MB3170/MB3270 Quick Installation Guide

MGate MB3170/MB3270 Quick Installation Guide MGate MB3170/MB3270 Quick Installation Guide Edition 7.1, February 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

M-Bus Central Unit. Use

M-Bus Central Unit. Use 6 M-Bus Central Unit OZW The M-bus central unit is used for the remote readout, remote operation and supervision of an M-bus plant with a maximum of consumption meters and controllers featuring an M-bus

More information

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications IA260 Series Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA Features and Benefits Cirrus Logic EP9315 Arm9 CPU, 200 MHz 128 MB RAM onboard, 32 MB flash disk

More information