PARKING CONTROL SYSTEM 119GU88-EN. SERIES PS Token INSTALLATION MANUAL PS HW. English

Size: px
Start display at page:

Download "PARKING CONTROL SYSTEM 119GU88-EN. SERIES PS Token INSTALLATION MANUAL PS HW. English"

Transcription

1 119GU88-EN PARKING CTROL SYSTEM SERIES PS Token INSTALLATI MANUAL PS HW English EN

2 2 PS TOKEN - Hardware and wiring SUMMARY TOPIC PAGE Parking system diagram and technical notes...4 Description of the units making up the PS BARCODE system...5 Technical data...5 Wiring Diagram...6 Dimensions, and anchoring bases...7 RBMP1 standard card description...9 PSR1 (PSE4000 PSU4000) basic card description...10 PSCA1 (PSC4000) card - description...11 PC30 description...12 PSI16 Auxiliary cash register control description...13 PSC1 Auxiliary cash registers description...14 PSIO1 Auxiliary device control - description...15 PSM4000 connections - (RBMP1) <--> Display <--> PC30 <-->PC...16 Display connections details...17 PSM4000 Connections - (RBMP1/PSI16) <--> PC via modem...18 Connections RBMP1 <--> PSR1 (PSE/PSU4000), PSCA1 (PSC4000) and PSF2 (PS6000/1)...19 PSM4000 connection (RBMP1) <--> Traffic lights...20 PSM4000 connections (RBMP1) <--> digital inputs...21 PSM4000 connections (RBMP1) <--> PSI16 and auxiliary (PSC1) cash registers...22 PSM4000 Connections (RBMP1) <--> PSIO PSE/PSU4000 Connections <---> Bar or other automated devices...24 Connections for the PSE4000 <---> Electromagnetic sensor (Coil)...25 Collegamenti PSE/PSU4000 <---> sensore transponder TSP PSCA2 + PSF2 (PSC6000/PSC6001) cards description...27 PSC6000/PSC6001 Connections...29 PSM4000 connections (RBMP1) <--> PSF2 (PSC6000/1)...30 Logical address assignation system components...31 List of system device addresses...32 Token loading procedure on PSE Token unloading procedure on the PSU Token issuing procedure...35 Coin loading procedure for the PSC6000/ Paper changing procedure on automatic cash registers...38 Setting the PSC6000/ COIN LOADING window Description...41 Setting the PSC6000/1 WITHDRAW window...42 How to withdraw coins manually...43 How to withdraw coins manually...43 How to withdraw banknotes...43 Setting the PSC6000/1 OPERATIS window...44 Setting the PSC6000/1 VARIOUS window...45 How to select the required language...46 How to change password...46 How to insert a telephone number to notify of any malfunctions...46 Setting the PSC6000/1 PRINTER window...47 How to read the receipt...47 Heating unit...48 RBMP1 DIP Switch Selecting functions...48 Accessing the AUTOMATIC PAY-STATI...49 p. 2 - Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

3 PS TOKEN - Hardware and wiring 3 INDUSTRIAL PC replacement INDUSTRIAL PC maintenance INDUSTRIAL TOUCH-SCREEN MITOR replacement INDUSTRIAL TOUCH-SCREEN MITOR maintenance VN9 BANKNOTE READER replacement VN9 BANKNOTE READER maintenance COIN VALIDATOR replacement COIN VALIDATOR maintenance COIN SELECTOR replacement COIN SELECTOR maintenance REPORT PRINTER replacement REPORT PRINTER maintenance TICKET DISPENSER replacement TICKET DISPENSER maintenance Replacing the BARCODE FIX-SCANNER p. 3 - Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

4 4 PS TOKEN - Hardware and wiring Parking system diagram and technical notes PSU4000 Magnetic coil Barrier PSM4000 PSC4000 Barrier PSE4000 Magnetic coil Traffic light The system and its software are able to manage up to 10,000 parking places, with a maximum of 2,500 registered users and 7,500 non-registered users. When designing a parking system one must take into account certain construction factors, in order to achieve maximum usability and safety for users. For example, planning for enough space for cars to steer in and out of the parking space. When driving into the parking lot, there needs to be enough room for the driver to pull up and collect a token or check into the system as a registered user. It is advisable to keep a distance of 2.5 m between the PSE4000 and the barrier. Also, there need to be clearly marked pedestrian transit lanes, featuring both horizontal and vertical signage. This is to prevent accidents and make pedestrian access quick and orderly, which in turn makes it easier for vehicles to access the parking lot. In any event, it is necessary to evaluate the morphology of the system (height differences, low visibility areas and so on) to try and prevent any collisions and dangerous steering, as well as dangerous situations for people in the parking lot. If needed, see to installing (zebra crossings, signage, mirrors, photocells, sensors, etc.) to reduce danger levels. Set up, upstream to the system, a dual-pole cut-off switch, with sectioned off power supply; (magnetothermic switch + differential switch) that has the following characteristics: Magnetothermic switch with maximum cut-off current of 6 A (230 V) or 10 A (120 V); differential switch with 30 ma of sensitivity. Use 4 mm² cables or greater when connecting the single devices to the site's grounding terminal. p. 4 - Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

5 PS TOKEN - Hardware and wiring 5 Description of the units making up the PS BARCODE system p. 5 - Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. PSM Manned cash register, complete with RBMP1 electronic control unit, management software, DISPLAY and PC30 interface for connecting up to a PC. PSE Entrance unit complete with sensor for transponder cards and key-fobs and (GET) token dispenser. PSU Steel exit unit complete with sensor for transponder cards and keyfobs and (GET) token collector. PSC Automatic cash register complete with sensor for transponder cards and key-fobs, accepts coins, with (GET) token reader and display; no change return device, with receipt dispenser. PSC Automatic cash register complete with personal computer, coin and banknote reader with change return device and credit card reader. PSC Automatic cash register complete with personal computer, coin and banknote reader with change return device. PSI16 - Interface for connecting up maximum 16 PSC1 units. PSC1 - Manual auxiliary cash register. Together with the PSI16 it provides a pay station without a permanently connected personal computer. PSIO1 - Auxiliary device controller for connecting up to PSSRV traffic lights, PSINS luminous signs, magnetic sensor and safety sensors (8 outputs max.). GET - Gettone transponder. PSINS - Double-sided vacant/full luminous sign. PSSRV- Traffic light with red-green lights, ø 200 mm. SMA - Single-channel magnetic sensor for detecting metallic masses. SMA2 - Dual-channel magnetic sensor for detecting metallic masses. Technical data PS TOKEN Power source Draw when idle PSM4000 Maximum power draw Max power output Protection rating RBMP1 230 V AC 50/60 Hz 35 ma AC PC30 12 V AC 175 ma AC - - IP20 DISPLAY 12 V AC 150 ma AC PSE V AC 50/60 Hz 98 ma AC * 180 ma AC *42 W IP54 PSU V AC 50/60 Hz 72 ma AC * 235 ma AC *55 W IP54 PSC V AC 50/60 Hz 125 ma AC * 200 ma AC *46 W IP40 PSC V AC 50/60 Hz 360 ma AC * 400 ma AC *92 W IP40 PSI V AC 50/60 Hz 35 ma AC PSC1 12 V AC 50/60 Hz 135 ma AC PSIO1 230 V AC 50/60 Hz 60 ma AC * With the heating unit active, the heating coil absorbs an extra 500 ma and requires an extra 90 W of power. ** PSC6000 also featuring a credit card reader. Working temperature - 20 / 55 C

6 COIN Came Cancelli Automatici è una società certificata ISO 9001 per il sistema di gestione della qualità aziendale e ISO per il sistema di gestione ambiantale. Came progetta e produce interamente in Italia. Came cancelli automatici s.p.a. 6 PS TOKEN - Hardware and wiring Wiring Diagram RBMP1 Central station PSM4000 Central control unit Maximum distance between the RBMP1 and the PC30, 1000m PC30 Interface RS232 cable Maximum 5m PC with Windows 98/2000/ xp/vista operating system Display Software RS232 cable Maximum 5m Serial printer via Martiri della Libertà, Dosson di Casier Treviso - Italy tel. (+39) fax (+39) info@came.it PSI16 Auxiliary cash register control PSC1 Auxiliary cash register (maximum 16 units) Serial printer RS232 cable Maximum 5m Maximum distance of the last PSC1, 1000m RS232 cable Maximum 5m PSI01 Auxiliary device control, e.g.: traffic lights magnetic coils luminous signs danger signs sensors (maximum 8 units) Barrier or other automation PSU4000 Exit unit (maximum 16 units) 1.5 mm2 Cables for 230 V a.c. MAGNETIC COIL 1.5 mm2 Cables for 230 V a.c. PSE4000 Entrance unit (maximum 16 units) PSINS PSC4000 Automatic cash register (maximum 8 units) Barrier or other automation PSSRV PSC6000/PSC6001 Automatic Cash Register (maximum 4 units) The system manages up to a maximum of 16 traffic lights that may be controller by either the RBMP1 or the PSI01 card????board??? Other unit (PSU4000 PSE4000 PSC4000 PSC7000/1) maximum distance between the RBMP1 and the last unit, 1000m * Suggested cable non-screened multi-pair braiede (CAT 5 - U/UTP - AWG 24) - ** Cable RS232, max 5 m - *** Cable Cross Null Modem, max 1.5 m. N.B. Computers and serial printers with relative cables are not supplied by Came. p. 6 - Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

7 PS TOKEN - Hardware and wiring 7 Dimensions, and anchoring bases PSE Base di ancoraggio ø 12.5 ø 70 ø p. 7 - Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. PSU4000 Anchoring base ø 12.5 ø COIN

8 8 PS TOKEN - Hardware and wiring PSC Anchoring base ø 12.5 ø PSC6000/ Anchoring base ø 13 ø 150 ø Secure, in stable fashion, the cabinets on suitable foundation concrete slabs. Use proper size dowels, in terms of diameter and length. Warning: a loose fitting may compromise the proper use of the tools and constitute a hazard 1755 p. 8 - Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

9 PS TOKEN - Hardware and wiring 9 RBMP1 standard card description p. 9 - Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. 5 6* 1- Line fuse 315mA 2- Circuit protection fuse 630mA 3- Not used 4- Not used 5- Terminal for connecting up the battery and battery charger (BN1 optional) 6- Power source terminal * board 7- Terminals for connecting devices to be managed (i.e. automation devices, alarms, traffic lights, etc.) Terminal for connecting the PC30 9- Terminal for connecting the PSE/PSU units 10- Terminals for connecting incoming digital devices 11- Warning LED light for circuit on and communication underway 12- Modem connection (or PSI16 if used) 13-5-way DIP Switch (for function detailed on page 45) The minimum, double insulated, cable section, depends on the characteristics and dimensions of the system, and must not be less than 2.5 mm². Before connecting up the device, cut off the mains power supply.

10 10 PS TOKEN - Hardware and wiring PSR1 (PSE4000 PSU4000) basic card description * Terminals for connecting to transformer 2-5A token unit protection fuse 3- Power source and 5A heating element protection fuse 4- Terminals for powering * 230 V a.c. card 5- Terminals for connecting power to internal heating unit 6- Thermostat contact to monitor heating unit (see p. 45) 7-24V a.c. output 8- Token unit power source 9- Motor command micro-switch 10- Terminals for connecting the devices that need to be commanded (i.e. automations) 11- Token request button contact 12- Terminal for connecting the magnetic coil (only on token enabled PSE4000 units) 13- Terminals for connecting sensors and keyboard 14- Terminals for connecting to the RBMP1 or to another PSR1 or to a REM 15- Token present reader sensor connection 16- Connection to TSP00 sensors 17- Token quality control contact 18- Connectors for (R700 R800) signal decoding cards 19- Circuit On warning LED light 20- DIP Switch selector 21-1A circuit protection fuse The minimum, double insulated, cable section, depends on the characteristics and dimensions of the system, and must not be less than 2.5 mm². Before connecting up the device, cut off the mains power supply. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

11 PS TOKEN - Hardware and wiring 11 PSCA1 (PSC4000) card - description TRANSFORMER TERMINAL BLOCK L1T L2T 24V 0 CTROL BOARD FUSE 1A PROGRAMM./EMULATOR CTROL BOARD PSCA1 R700 2 LINE FUSE 5A WARNING! V1 V2 V3 6 1* L N POWER SUP. RESISTANCE 230V AC THERMOSTAT CTACT OUTPUT 24V AC BARRIER COMMAND CNECTI TO PSCAR1 A B GND 1 A B GND 2 S1 GND TSP00 p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. 1 - Terminals to power the * 230 V a.c. card 2 - Terminals for connecting power to internal heating unit 3 - (Control board) circuit protection fuse 4 - Circuit LED warning light 5 - DIP Switch selector 6 - Connector for (R700) signal decoding cards 7 - Terminals for connecting to the RBMP1 or to another PSCA1 or to a PSR1 The minimum, double insulated, cable section, depends on the characteristics and dimensions of the system, and must not be less than 2.5 mm². Before connecting up the device, cut off the mains power supply. 7

12 12 PS TOKEN - Hardware and wiring PC30 description V a.c. power input 2 - RS232 Serial port for connecting up Personal Computer 3 - Terminals for connecting up RBMP1 (RS485 serial port) 4-12V a.c. power supply unit 5 - Cable complete with RS m connectors 6 - Keyboard for memorising S5000/S6000/S7000 selector codes Area for TST01 Card (proximity card) memorisation and GET token reading 8 - Power LED warning light 9 - LED warning light for code or proximity card reading The minimum, double insulated, cable section, depends on the characteristics and dimensions of the system, and must not be less than 2.5 mm². Before connecting up the device, cut off the mains power supply. 2 1 p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

13 PS TOKEN - Hardware and wiring 13 PSI16 Auxiliary cash register control description CTROL BOARD PSI16 PROGRAMMING V1 V2 V3 V4 V5 LINE FUSE 315mA A B GND 1 A B GND 2 A B GND 3 A B GND 4 A B GND 5 A B GND 6 A B GND 7 A B GND 8 1 p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. L 2* N CTROL BOARD FUSE 630 ma 1 - Power surge protection fuse 3 A B GND 2 - Terminals for powering the 230 V a.c. * circuit board??? 3 - Circuit protection fuse (Control Board) 4 - Terminals for connecting PS13 units 9 A B GND 10 A B GND 11 A B GND 12 4 A B GND 5 - Power on warning LED light 13 A B GND 14 A B GND 6 - RS232 connector for connecting up RBMP1 card 7 - RS232 connector for connecting up MODEM The minimum, double insulated, cable section, depends on the characteristics and dimensions of the system, and must not be less than 2.5 mm². Before connecting up the device, cut off the mains power supply. Have in place a suitable dual pole cut-off switch with minimum contact openings of 3 mm, and section the power supply; 15 A B GND 16

14 14 PS TOKEN - Hardware and wiring PSC1 Auxiliary cash registers description The PSC1 unit is an auxiliary cash register, and as such it allows occasional user exits. This peripheral unit is much used in shopping malls or supermarkets, as it allows several units to be installed to grant free or discounted parking to shoppers V a.c. power input 2 - Connector for serial printer 3 - Connector for connecting up to PSI V a.c. power supply unit Command keyboard 6 - Power on warning LED light 7 - GET transponder token clearing reader 8 - Display 1 p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

15 PS TOKEN - Hardware and wiring 15 PSIO1 Auxiliary device control - description p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. 1* 1- Terminals for powering te 230 V a.c. board 2 - Power surge protection fuse 3 - PSIO1 Board protection fuse 4 - Terminals for connecting to RBMP1 or to another PSIO1 5 - Terminals for connecting up input devices (Coils, Photocells, etc.) DIP Switch 7 - Relay warning LED light 8 - Terminals for connecting up control devices (i.e. traffic lights, magnetic coils, etc.) 9 - Communication warning LED light 10 - Board power warning LED light The minimum, double insulated, cable section, depends on the characteristics and dimensions of the system, and must not be less than 2.5 mm². Before connecting up the device, cut off the mains power supply. Have in place a suitable dual pole cut-off switch with minimum contact openings of 3 mm, and section the power supply; 7

16 16 PS TOKEN - Hardware and wiring PSM4000 connections - (RBMP1) <--> Display <--> PC30 <-->PC Personal Computer PC30 GND B A 1.5 M CABLE for RS232 serial ports complete with connectors Cable* NOT INCLUDED Suggested type: nonscreened, twisted multipaired (CAT 5 U/UTP AWG24) Display connections details * AWG24 cable connection colours White/Orange braided on GND White/Green braided to split: White on A Green on B Insulate the remaining pairs. Cable* NOT INCLUDED Suggested type: nonscreened, twisted multipaired (CAT 5 U/UTP AWG24) RS V a.c. power supply unit for 230 V a.c Hz mains Working temperature between -20 to +50 C RBMP1 p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

17 PS TOKEN - Hardware and wiring 17 Display connections details 12V a.c. power supply unit for 230 V a.c Hz mains Working temperature between -20 to +50 C Serial printer NOT INCLUDED Required features characters per line 24 Serial Baud Rate Character Parity Flow control New paragraph RS bps 8 Bits none X / XOFF Enabled on CR Cable* NOT INCLUDED Suggested type: non-screened, twisted multi-paired (CAT 5 U/ UTP AWG24) p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. Cable* NOT INCLUDED Suggested type: nonscreened, twisted multipaired (CAT 5 U/UTP AWG24) * AWG24 cable connection colours White/Orange braided on GND White/Green braided to split: White on A Green on B Insulate the remaining pairs. RBMP1 N.B. Be careful with the order of the wires, the colour should match the display and the RBMP1 (A B GND).

18 18 PS TOKEN - Hardware and wiring PSM4000 Connections - (RBMP1/PSI16) <--> PC via modem Warning! The telephone number which will be inputed to make the call is that of the modem connected to the RBMP1 PC for remote control Built in or external modem Telephone line RBMP1 or, if present, PSI16 RS232 cable MODEM Warning!! Each time you hook up a modem, cut off and power back up again the RBMP1 board Communication takes place among a PC, its modem, the receiving modem and the RBMP1, during connection any parameter can be modified, and any information may be read. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

19 Line B* Line A* PS TOKEN - Hardware and wiring 19 Connections RBMP1 <--> PSR1 (PSE/PSU4000), PSCA1 (PSC4000) and PSF2 (PS6000/1) Two-way connection: the RBMP1 may be situated along any point of the cable route RBMP1 RBMP1 PSR1 Between the first and last PSR1/PSACA1/PSF2, la the distance (meaning the route of the connection cable) must be 1000 m long maximun PSCA1 PSCA2 PSCA1 Cable* NOT INCLUDED Suggested type: nonscreened, twisted multipaired (CAT 5 U/UTP AWG24) Cable* NOT INCLUDED Suggested type: nonscreened, twisted multipaired (CAT 5 U/UTP AWG24) p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. Each unit is identified by the RBMP1 thanks to progressive sequential numbering, independently from the position along the connection cable route; such numbering (also known as an address) must be set on the relative DIP Switch on the peripheral unit s board (Entrance or Exit units and automatic cash register) PSR1/PSCA1/PSF At the subsequent* PSR1/PSCA1/PSF2 (entrance and exit connectable on either terminal boards 1 or 2) *The PSR1 cards equip the PSE/PSU4000 entrance/exit units, while the PSCA1s equip the PSC4000/1 cash registers, and the PSCA2s equip the PSC6000/1 cash registers. * AWG24 cable connection colours White/Orange braided on GND White/Green braided to split: White on A Green on B Insulate the remaining pairs. PSR1/PSCA1/PSF2 At the subsequent* PSR1/PSCA1/PSF2 (entrance and exit connectable on either terminal boards 1 or 2)

20 20 PS TOKEN - Hardware and wiring PSM4000 connection (RBMP1) <--> Traffic lights 230 V a.c. N = Black = GREEN/FREE M = Brown = RED/FULL B = Blue = Common N M B Partial traffic lights, associated to different floors or sectors, up to a maximum of 8, controlled by standard issue software. The minimum, double insulated, cable section, depends on the characteristics and dimensions of the system, and must not be less than 2.5 mm². Before connecting up the device, cut off the mains power supply. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

21 PS TOKEN - Hardware and wiring 21 PSM4000 connections (RBMP1) <--> digital inputs Digital inputs are use to connect up the magnetic coils which instantly provide a count of the number of vehicles in the parking facility, they command the traffic lights independently of the PSE/PSU4000 entrance and exit units. They are often used in multi-level parking, or ones with one entrance and one exit. The coils may be used to obtain an exact count of the number of vehicles on each level, which provides and exact number of free spaces on each parking level. Example of multi-level parking with vehicle count coils on each level. Traffic light Traffic light Exit magnetic coil Entrance magnetic coil Traffic light PSM4000 p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. PSU4000 PSC4000 RBMP1 PSE4000 Entrance magnetic coil Traffic light Method to connect the extra RBMP1/PSIO coils, to count the exact number of cars at each floor. A tw-channel detector device such as th e SMA2 is preferable, used in mono-directional mode. Also see product literature. Exit SMA2 Entrance SMA2

22 22 PS TOKEN - Hardware and wiring PSM4000 connections (RBMP1) <--> PSI16 and auxiliary (PSC1) cash registers 12V a.c. power supply unit for 230 V a.c Hz mains Working temperature between -20 to +50 C PSC1 Serial printer NOT INCLUDED Required features characters per line Serial Baud Rate Character Parity Flow control New paragraph 24 RS bps 8 Bits none X / XOFF Enabled on CR (GND) Diagram for connecting up to the control board s main (RBMP1) panel of the PSI16 auxiliary cash registers, and for connecting to the PSC1 auxiliary cash registers, maximum distance 1000 m. * AWG24 cable connection colours White/Orange braided on GND White/Green braided to split: White on A Green on B Insulate the remaining pairs. RBMP1 (B) (A) RS232 PSI16 Cable NOT INCLUDED for RS232 serial ports Cable* NOT INCLUDED Suggested type: nonscreened, twisted multipaired (CAT 5 U/UTP AWG24) PSI16 Warning!: connect the adapter cable supplied with the PSI16. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

23 PS TOKEN - Hardware and wiring 23 PSM4000 Connections (RBMP1) <--> PSIO1 RBMP1 p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. * AWG24 cable connection colours White/Orange braided on GND White/Green braided to split: White on A Green on B Insulate the remaining pairs. TRANSFORMER TERMINAL BLOCK LINE FUSE 5A L 230 V 0V 24V N 230V AC U2 CTROL BOARD FUSE 630mA A B GND A B GND PSIO1 Nc NC No NO C Nc NC No NO C Nc NC No NO C Nc NC No NO C Nc NC No NO C Nc NC No NO C Nc NC No NO C Nc NC No NO C OUT 1 OUT 2 Cable* NOT INCLUDED Suggested type: nonscreened, twisted multipaired (CAT 5 U/UTP AWG24) PSIO1 TAMPER P1 P2 P3 P4 Com P5 P6 P7 P8 Com OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT V1 V2 V3 V4 V5

24 PSR COIN PSR PS TOKEN - Hardware and wiring PSE/PSU4000 Connections <---> Bar or other automated devices Connection is the same for either the PSE unit or the PSU unit COIN PSR p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

25 PSR COIN PS TOKEN - Hardware and wiring 25 Connections for the PSE4000 <---> Electromagnetic sensor (Coil) The detection metal mass detector sensor can only connect to the PSE4000 p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. Electromagnetic metal mass (vehicle) detection sensor PSR

26 COIN PS TOKEN - Hardware and wiring Collegamenti PSE/PSU4000 <---> sensore transponder TSP00 A GREEN LED indicator light inside the TSP00 means the reader is not properly set. A RED LED indicator light inside the TSP00 means the reader is properly set. Transponder reader TSP00 for proximity Card Proximity card TST01 The connection is the same for either the PSE or the PSU unit COIN RED = S1 BLACK = GND PSR1 p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

27 PS TOKEN - Hardware and wiring 27 PSCA2 + PSF2 (PSC6000/PSC6001) cards description PSCA2 managing primary components L1T L2T 35V 24V 0V LAMPADA p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. 3 4* R700 L N NC NO C A B GND KEY1 K KEY2 TAMPER AUX OUT S1 GND CSENSO STAMPANTE MITOR PC OUT PC485 TSP00 TASTIERA 1- Terminals for connecting to transformer 2-6.3A Card protection fuse A Power surge protection fuse V power source (from PSF2) 5- Terminals for connecting indoor courtesy lamp 6- Connector for connecting RS232 PC cable 7- Connector for processing banknotes 8 - Plug connector for POS system 9 - Change return processing connector 10 - Token dispenser connection 11- External keyboard connector 12 - R700 signal decoding card connector 13 - Cash register address DIP Switch 14- Connector Plug for printer ICM330 badge reader unit connector Contact linking terminal for cash register configuration (closing the contact causes a keyboard to appear on the monitor) 17- Connection to TSP00 sensors 18- Auxiliary output???exit??? Terminal clip (not used) 19- Terminal clip for open cash register warning 20- Terminal clip for connecting sensor on open cash register keys 21 - Terminal clip already connected 22 - Output terminal clip 23- Terminal clip for powering PC Monitor 24 - Terminal clip for Printer power 25- Power LED warning light

28 28 PS TOKEN - Hardware and wiring PSCA2 + PSF2 (PSC6000/PSC6001) cards description PSF2 managing auxiliary components 1* L N LAMPADA TERMOSTATO RESISTENZA HELP CITOFO A B GND Terminals for powering the 230 V a.c. * board 2 - Terminal clip for connecting internal lamp (already connected) 3 - Terminal clip for connecting the internal thermostat (already connected) 4 - Terminal clip for connecting anti-freeze heating element (already connected 5 - Terminal clip for connecting HELP button 6- Terminal clip for connecting a possible intercom 7- Terminal clip for connecting automatic cash register to other cash registers or parking facility components 8- Already connected The minimum, double insulated, cable section, depends on the characteristics and dimensions of the system, and must not be less than 2.5 mm². Before connecting up the device, cut off the mains power supply. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

29 L N LAMPADA TERMOSTATO RESISTENZA HELP CITOFO A B GND PS TOKEN - Hardware and wiring 29 PSC6000/PSC6001 Connections Overall, the auxiliary and utility inputs inside the cash register, are rated for a maximum of 1A 250W p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. 230 V 50/60 Hz L N Already connected LAMPADA TERMOSTATO RESISTENZA HELP CITOFO A B GND Already connected button Intercom Warning! Perform the grounding directly onto the frame of the cash register, exactly as shown in the photograph. At the subsequent* PSR2/PSF2 (entrance and exit connectable on either terminal boards 1 or 2)

30 30 PS TOKEN - Hardware and wiring PSM4000 connections (RBMP1) <--> PSF2 (PSC6000/1) RBMP1 L * AWG24 cable connection colours White/Orange braided on GND White/Green braided to split: White on A Green on B Insulate the remaining pairs. N LAMPADA TERMOSTATO RESISTENZA HELP CITOFO A B GND Cable* NOT INCLUDED Suggested type: nonscreened, twisted multipaired (CAT 5 U/UTP AWG24) p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

31 PS TOKEN - Hardware and wiring 31 Logical address assignation system components For the RBMP1 to communicate with the other connected devices (i.e. PSE, PSU, PSU, PSI01 and PSC7000/1) each of these must be assigned a univocal address; set the DIP Switches in the their control boards as shown in the following pages. ND ND ND PSIO NC A NO B GND C NC A NO B GND L CN NC A NO B GND C NC A NC ANO B GND NO BC GND C1 2NC A 3 BNO 4 GND 5NC AC 6 NO B7 8GND NC A 9C 10NO B GND C NC A NO BNC A GND NO BCGND C NC A NO B GND C NC A NO B GND C NC A NO B GND C NC A NO B GND C OUT 3 TAMPER P1 P2 P3 P4 Com P5 P6 P7 P8 Com TRANSFORMER TERMINAL BLOCK LINE FUSE 5A OUT 4230V AC 230 V 0V 24V U2 PSIO1 OUT 5 CTROL BOARD FUSE 630mA OUT OUT 1 6 A B GND A B GND OUT OUT 7 OUT V1 4 V2 5 6 V3 7 V4 8 9 V V1 4 V2 5 6 V3 7 V4 8 9 V V1 V2 V3 V4 V5 OUT OUT 8 4 TAMPER P1 P2 P3 P4 Com P5 P6 P7 P8 Com PSIO1 OUT 5 OUT NC A NO B GND C NC A NO B GND C NC A NO B GND C NC A NO B GND C NC A5 6 NO B7 NC NO C NC NO C GND 8 NC C9 10 L N A A NO B GND C NC A NO BNC A GND NO BC 1 B2 GND A7 8B 9GND 10 GND C NC A NO B GND C NC A NO B GND C NC A NO B GND C NC A NO B GND C OUT 3 TAMPER P1 P2 P3 P4 Com P5 P6 P7 P8 Com TRANSFORMER TERMINAL BLOCK LINE FUSE 5A TRANSFORMER TERMINAL BLOCK OUT 4230V AC LAMPADA A B GND A B GND LINE FUSE 5A 230 V 0V 24V U2 PSIO1 OUT 5 CTROL BOARD FUSE 630mA OUT OUT 1 6 A B GND A B GND OUT 2 OUT 7 OUT 3 OUT OUT 8 4 TAMPER P1 P2 P3 P4 Com P5 P6 P7 P8 Com PSIO1 OUT 5 OUT 6 OUT NC A NO B GND C NC A NO B GND L CN NC A NO B GND C NC A NC ANO B GND NO BC GND C NC A BNOGND NC AC NO B GND NC AC NO B GND C NC A NO BNC A GND NO BCGND C NC A NO B GND C NC A NO B GND C NC A NO B GND C NC A NO B GND C OUT 3 TAMPER P1 P2 P3 P4 Com P5 P6 P7 P8 Com OUT 4230V AC 230 V 0V 24V PSIO1 U2 OUT 5 CTROL BOARD FUSE 630mA A B GND A B GND TAMPER P1 P2 P3 P4 Com P5 P6 P7 P8 Com OUT OUT OUT OUT 7 OUT 3 PSIO V1 V2 V3 V4 V5 OUT OUT 8 4 TAMPER P1 P2 P3 P4 Com P5 P6 P7 P8 Com PSIO1 C NO B GND C NC A NO B GND C NC A NO B GND C NC A NO B GND C NC R700 A NO B GND C NC A NO B GND C NO B OUT GND C NC 3 A BNOGND C NC A NO B GND C NC A NO B C NC NO C NC NO C NC NO C NC NO C OUT 4 OUT 5 OUT GND 6 A B OUT GND A B GND A B GND1 2A 3B GND 4 7 OUT 8 T ITOR PC p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. OUT 2 TRANSFORMER TERMINAL BLOCK 230 V 0V 24V OUT 3 CTROL BOARD FUSE 630mA OUT 4 TAMPER P1 P2 P3 P4 Com P5 P6 P7 P8 Com OUT 5 NC NO C A B GND S1 GND CSENSO KEY1 K KEY2 TAMPER AUX OUT OUT PC485 TSP00 TASTIERA LINE FUSE 5A U PSR1 PSE4000 PSR1 PSU4000 PSCA1 PSC4000 PSIO1 Device control extension PSCA2 PSC6000/6001 A B GND A B GND OUT The flashing LED indicator means proper dialogue is taking place with the RBMP1 board OUT 7 The flashing LED indicator means proper dialogue is taking place with the RBMP1 board. OUT 5 PSIO1 OUT V1 V2 V3 V4 V5 OUT OUT OUT 7 TAMPER P1 P2 P3 P4 Com P5 P6 P7 P8 Com OUT 8 The flashing LED indicator means proper dialogue is taking place with the RBMP1 board. OUT 8 The flashing LED indicator means proper dialogue is taking place with the RBMP1 board. OUT 8 The flashing LED indicator means proper dialogue is taking place with the RBMP1 board. default default default default default V1 V2 1 V3 2 V4 3 4 V V1 V2 V3 1 2 V4 3 4 V V1 V2 V3 V4 V V1 V2 V3 V4 V5

32 32 PS TOKEN - Hardware and wiring List of system device addresses PSE4000 Number of serial position The DIP Switches on the various cards are factory-set to the n.1 position. Set Dip-switch 10 to in case a termination is necessary on RS485 line. Switch * N 1 OFF OFF OFF OFF OFF OFF OFF OFF OFF N 2 OFF OFF OFF OFF OFF OFF OFF OFF N 3 OFF OFF OFF OFF OFF OFF OFF OFF N 4 OFF OFF OFF OFF OFF OFF OFF N 5 OFF OFF OFF OFF OFF OFF OFF OFF N 6 OFF OFF OFF OFF OFF OFF OFF N 7 OFF OFF OFF OFF OFF OFF OFF N 8 OFF OFF OFF OFF OFF OFF N 9 OFF OFF OFF OFF OFF OFF OFF OFF N 10 OFF OFF OFF OFF OFF OFF OFF N 11 OFF OFF OFF OFF OFF OFF OFF N 12 OFF OFF OFF OFF OFF OFF N 13 OFF OFF OFF OFF OFF OFF OFF N 14 OFF OFF OFF OFF OFF OFF N 15 OFF OFF OFF OFF OFF OFF N 16 OFF OFF OFF OFF OFF PSU4000 Number of serial position Switch N 1 OFF OFF OFF OFF OFF OFF OFF OFF N 2 OFF OFF OFF OFF OFF OFF OFF N 3 OFF OFF OFF OFF OFF OFF OFF N 4 OFF OFF OFF OFF OFF OFF N 5 OFF OFF OFF OFF OFF OFF OFF N 6 OFF OFF OFF OFF OFF OFF N 7 OFF OFF OFF OFF OFF OFF N 8 OFF OFF OFF OFF OFF N 9 OFF OFF OFF OFF OFF OFF OFF N 10 OFF OFF OFF OFF OFF OFF N 11 OFF OFF OFF OFF OFF OFF N 12 OFF OFF OFF OFF OFF N 13 OFF OFF OFF OFF OFF OFF N 14 OFF OFF OFF OFF OFF N 15 OFF OFF OFF OFF OFF N 16 OFF OFF OFF OFF PSC4000 Switch Number of serial position N 1 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF N 2 OFF OFF OFF OFF OFF OFF OFF OFF OFF N 3 OFF OFF OFF OFF OFF OFF OFF OFF OFF N 4 OFF OFF OFF OFF OFF OFF OFF OFF N 5 OFF OFF OFF OFF OFF OFF OFF OFF OFF N 6 OFF OFF OFF OFF OFF OFF OFF OFF N 7 OFF OFF OFF OFF OFF OFF OFF OFF N 8 OFF OFF OFF OFF OFF OFF OFF p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

33 PS TOKEN - Hardware and wiring 33 PSI01 Switch Number of serial position N 1 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF N 2 OFF OFF OFF OFF OFF OFF OFF OFF OFF N 3 OFF OFF OFF OFF OFF OFF OFF OFF OFF N 4 OFF OFF OFF OFF OFF OFF OFF OFF N 5 OFF OFF OFF OFF OFF OFF OFF OFF OFF N 6 OFF OFF OFF OFF OFF OFF OFF OFF N 7 OFF OFF OFF OFF OFF OFF OFF OFF N 8 OFF OFF OFF OFF OFF OFF OFF PSC6000/1 Number of serial position Switch 1 2 3* 4** N 1 OFF OFF OFF N 2 OFF OFF N 3 OFF OFF N 4 OFF * (default) Model NV9 bank-bill receiver. OFF MATRIX model bank-bill receiver. ** OFF (default) Model RM5 coin receiver. GIODY model coin receiver. Token loading procedure on PSE4000 p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice add the required amount of tokens COIN 1- release the locks, using the apposite keys 2-pull outwards on the PSE4000 unit panel 4-press the button shown to properly position the first token, then close the token dispensino unit back up again. 2 4

34 34 PS TOKEN - Hardware and wiring Token unloading procedure on the PSU release the locks, using the apposite keys 2 2- open the small door COIN 3 3- remove the token inside the container, then close back up again. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

35 PS TOKEN - Hardware and wiring 35 Token issuing procedure - Stop the car atop the metal mass detection coil. - Press the red button on the PSE4000 entrance unit. - Retrieve the token from the tray. The token must be stored carefully for it work when exiting at one of the parking facility s cash registers. Corrugated ø 25 mm flexible tube for signal cables (type U/UTP Cat 5 AWG 24) Corrugated ø 35 mm flexible tube for power cables EXAMPLE OF ENTRANCE AND EXIT CFIGURATI min Safety coil 500 GARD BAR 300 p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. Coil controller Minimum suggested section for the cement base of the devices 150 Coil controller Safety coil 600 EXIT PSU EXIT UNIT PSE ENTRANCE UNIT GARD BAR ENTRANCE 1800 Parked vehicle detection coil Entrance coil controller

36 36 PS TOKEN - Hardware and wiring Coin loading procedure for the PSC6000/1 Release the cash register using the apposite keys Pull on the top section of the cash register to open it (you may need to insert your hand into the coin retrieval well. Once opened, press the button located on the panel box. A software access window will open: Enter the following password (default 1234) directly onto the monitor using the keypad and confirm by pressing E (in case of error, press C to cancel). Once the password is entered, a group of windows will open. Into the window, type WITHDRAW and in the box labelled ENABLE enter the denomination of banknotes accepted for payment; the greater denomination shall also be the minimum value of the coins that the change giving device may hold. changes Click on the SAVE button to validate the p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

37 PS TOKEN - Hardware and wiring 37 In the Loaded Coins box set the number of coins that you are going to actually load into the cash register. The right-hand buttons increase the number, while those on the right, decrease the number. changes Click on the SAVE button to validate the p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. Insert the coins into the apposite container which is located just behind the cash register front-piece, while being careful to enter the exact number of coins registered on the software.

38 38 PS TOKEN - Hardware and wiring Paper changing procedure on automatic cash registers. 1. Release the locks and open the panel-door completely. 2. Cutt off power supply to the printer. 3. Free the roll support by pressing the apposite lock-teeth and removing the side band. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

39 PS TOKEN - Hardware and wiring Insert the new roll. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. 6. Place paper in the apposite slit under the roll support - the printer will hook it automatically. Close the panel-door. 5. Power up again.

40 40 PS TOKEN - Hardware and wiring Setting the PSC6000/1 3 Once opened, press the button located on the panel box. 1 Release the cash register using the apposite keys 2 Pull on the handles to open the top section of the cash register. A software access window will open: Enter the following password (default 1234) directly onto the monitor using the keypad and confirm by pressing E (in case of error, press C to cancel). p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

41 PS TOKEN - Hardware and wiring 41 COIN LOADING window Description p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice Touch screen activation button 2- Save settings button 3 - Monetary value reduction column 4 - Box to view the total monetary value contained in the cash register 5- Number of the connected cash register Click on the SAVE button to validate the changes 6 - Box to view the monetary value of each single fraction or coin unit. 7 - Monetary value increase column 8 - END button to conclude various operations. 9- Setting the maximum allowed change N.B.: To load the coins read the instructions on pages 35 and 36. Each time someone pays the toll, the central box (6) will be updates with the number of inserted coins and the lower box (4) will always display the total sum of the value in the cash register

42 42 PS TOKEN - Hardware and wiring Setting the PSC6000/1 WITHDRAW window Manual coin withdrawal button from the cash register (the button only serves to update the software in case coins are manually removed from the cash register). 2 - Automatic withdrawal button. 3- Box which displays the total value of coins to be withdrawn. 4- By selecting boxes on the touch screen, various monetary values to be withdrawn can be entered, depending on the fractions or coin units (0.05, 0.10, ). 5- Touch screen activation button. 6- Manual banknote withdrawal button from cash register (the button only serves to update the software in case banknotes are manually withdrawn from the cash register). 7- Box which displays the total value of banknotes to be withdrawn. 8 - Number of the connected cash register. 9 - By selecting boxes on the touch screen, various monetary values to be withdrawn can be entered. 10- Using these boxes allows you to enable the banknote values that can be inserted into the cash register. 11- Button to save the banknote value settings. 12- END button to conclude the various operations. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

43 PS TOKEN - Hardware and wiring 43 How to withdraw coins manually Open the register with the apposite keys. 2. Activate tbe button located aboe the control panel box. 3. Access the software via password. 4. Use keyboard, enter the number of coins to withdraw for each denomination or just enter the total, leaving the choice of denominations to the register. 6. Manually remove from the container the coins you wish to withdraw. 7. Click on the button with the small hand to update the software. Warning: always check that the entered values and actual coins in the register exactly match. How to withdraw coins manually p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. 5 How to withdraw banknotes Open the cash register using the apposite keys. 2. Press the button located on the panel box. 3. Use password to access the software. 4. Use the keypad to enter the number of coins to withdraw. 5. Click on the button (which has a small arrow diagram) 6. The change giving device will automatically dispense the exact number of coins which you have chosen for withdrawal. Warning: always check that the entered values and actual coins in the register exactly match. 1. Open the cash register using the apposite keys. 2. Press the button located on the panel box. 3. Use password to access the software. 4. Use the keypad to enter the number of banknotes to withdraw. 5. Click on the button (which has a small arrow diagram) to update the software. 6. Remove the box containing the banknotes. 7. Remove from the box only the banknotes which you have decided to withdraw. Warning: always check that the entered values and actual coins in the register exactly match.

44 44 PS TOKEN - Hardware and wiring Setting the PSC6000/1 OPERATIS window Button to activate the touch screen keyboard. 4- Operations carried out information window. 2- Cancel file button (once pressed all files will be cancelled) 5- Number of cash register connected. 3- Button to export operations in text format file. 6- END button to conclude various operations. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

45 PS TOKEN - Hardware and wiring 45 Setting the PSC6000/1 VARIOUS window p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. 1 - Software language selection box. 2 - TSAVE language box. 3 - Password change or enter box. 4 - Touch screen activation box. 5 - Button to halt management software and to switch display to operating system. N.B. : To return to the management software, click twice on the following icon: 6 - Cash register components diagnostic box. 7 - Telephone number for Text messaging alarms: by connecting an (optional) GSM modem the software will send a warning Text message in the event of selected malfunctions (see point 9 below). 8 - Button to save diagnostic settings. 9 - Selecting these boxes, activates alarms that in case of system component malfunctions. A Text message is sent if a GSM modem is connected up Number of cash register connected END button to conclude various operations.

46 46 PS TOKEN - Hardware and wiring How to select the required language Open the cash register using the apposite keys. 2.Press the button located on the panel box. 3.Use password to access the software. 4.Select the VARIOUS box. 5.Select the required language. 6.Save the setting. How to change password Open the cash register using the apposite keys. 2.Press the button located on the panel box. 3.Use password to access the software. 4.Select the VARIOUS box. 5.Enter the new password. 6.Re-enter the new password. 7.Save the setting. How to insert a telephone number to notify of any malfunctions Open the cash register using the apposite keys. 2. Press the button located on the panel box. 3. Use password to access the software. 4. Select the VARIOUS box. 5. Enter the telephone number in the given space. 6. Click on the SAVE button to validate the function. Warning: the Test Text message sending function is active only when the GSM modem is connected to the system. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

47 PS TOKEN - Hardware and wiring 47 Setting the PSC6000/1 PRINTER window CAME spa Via Martiri della Liberta 15 TREVISO -- ITALY Per rimborso, rivolgersi a: Mario Rossi c/o Uscita Piazzale Est. machina : p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice Window for entering name of the company managing the parking facility. 2- Button to cancel phrases selected on the Printer Heading. 3 - Button to save Heading on window. 4- Button to activate internal keypad. 5- Window to enter data of person assigned to giving reimbursements in case change is not returned or system malfunction. How to read the receipt Name of the company managing the parking facility Counter for the number of transactions made Amount due Change due If the cash register does not have enough change, the amount not returned is show Receipt issue date CAME Cancelli Automatici S.p.A. via Martiri della Libertà Dosson di Casier TREVISO - ITALY Cassa automatica : Operazione N : 7 tipo : gettone 0F45EB7F Importo : 0,50 Pagato : 0,80 Resto : 0,30 Resto erogato : 0,20 Resto Non erogato : 0, Per Rimborso, rivolgersi a: Ditta Mario Rossi c/o Uscita Piazzale Est. tel Treviso 26/02/2008, 10:12:20 6- Button to cancel phrases selected on Reimbursements. 7- Button to save Reimbursement data on window. 8- Number of cash register connected. 9- END button to conclude carious operations. Number of the automatic cash register which issued the receipt Type of subject used in the calculation Amount paid or inserted Change given Name of company to contact in case of change not given or cash register malfunction

48 48 PS TOKEN - Hardware and wiring Heating unit With condensation and/or extreme temperatures, we suggest switching on the heating unit using the apposite thermostat. Thermostat Heating element RBMP1 DIP Switch Selecting functions DIP Switches 1 and 2 = select s the time available for barrier to open, once token is retrieved from the PSC4000 s tray. DIP Switch 4 = select time available for payment, once token is placed on the PSC4000 s sensor. OFF OFF Dip 1 e 2 OFF...3 seconds Dip seconds. OFF OFF Dip 1, 2 OFF...5 seconds Dip 4 OFF...2,5 seconds (suggested). OFF Dip 1 OFF, seconds OFF Dip 1, seconds N.B.: DIP Switch 3 and 5 not used, leave in the OFF position. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

49 PS TOKEN - Maintenance guide 49 Accessing the AUTOMATIC PAY-STATI CUT OFF THE MAINS POWER SUPPLY. use the supplied keys to open the unit p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. pull towards yourself on the two handles fitted to the front of the unit

50 50 PS TOKEN - Maintenance guide If replacing inner accessories should present any difficulties, remove the unit's front piece by following the following instructions. WARNING! Two or more people are required for this procedure. disconnect the cables Loosen the screw remove the metal plate Remove the panel by moving it to the opening limit switch, lift and pull towards yourself. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

51 PS TOKEN - Maintenance guide 51 INDUSTRIAL PC replacement spare part code -> 119RIR362 unplug all cables beneath the industrial PC Warning! PC power supply = 24 V DC p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. INDUSTRIAL PC maintenance The industrial PC needs periodic maintenance. loosen the four screws

52 52 PS TOKEN - Maintenance guide INDUSTRIAL TOUCH-SCREEN MITOR replacement spare part code -> 119RIR363 unplug the cables beneath the 119RIR362 industrial PC unplug the cables beneath the 119RIR363 monitor INDUSTRIAL TOUCH-SCREEN MITOR maintenance Clean using a moist cloth, specific for PC monitor cleaning. Do not use alcohol or aggressive detergents. loosen the six nuts Warning! Hold the touchscreen monitor with your hand. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

53 PS TOKEN - Maintenance guide 53 VN9 BANKNOTE READER replacement spare part code -> 119RIR365 slightly move the holding tab remove the banknote collector, moving it upwards and towards you. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. press the two tabs to remove the NV9 banknote reader unplug the cable

54 54 PS TOKEN - Maintenance guide VN9 BANKNOTE READER maintenance Maintenance must be done once per month. Warning! Do not lubricate the NV9 banknote reader move the tab to the right open the NV9 banknote reader p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

55 PS TOKEN - Maintenance guide 55 The NV9 banknote reader's capacity is 300, maximum for cleaning inside, use a soft moist nonfrayed cloth. be sure that the sensor lenses are properly cleaned and dry. the lenses on the front sensor must be cleaned with either a wad or a soft brush. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

56 56 PS TOKEN - Maintenance guide COIN VALIDATOR replacement unplug the cable spare part code -> 119RIR360 with a flat head screwdriver, slightly move the holding tab... COIN VALIDATOR maintenance and remove the coin validator. from the support. Maintenance must be done once per month. Use compressed air to clean the coin validator. Warning! Do not lubricate the coin validator. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

57 PS TOKEN - Maintenance guide 57 COIN SELECTOR replacement spare part code -> 119RIG295 unplug the cable p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. loosen the two screws lift and remove from the metal support, the coin selector.

58 58 PS TOKEN - Maintenance guide COIN SELECTOR maintenance Perform periodic maintenance according to the operating conditions (at least once per year). Warning! Do not lubricate the coin selector. clean the coin exit slot, with compressed air clean the inside of the coin selector, moving the holding tab leftwards and using a screwdriver to lift the hatch door. clean using compressed air and a moist unfrayed cloth (including the coin basket) p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

59 REPORT PRINTER replacement PS TOKEN - Maintenance guide 59 spare part code 119RIR361 disconnect the two cables: power and data supplies turn the green knob counter clockwise, until the paper extracts from the printer. Compress the center tabs and remove the white roll holding disc. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. cut automatically. loosen the four fastening screws. once the printer is replaced, cut the paper edge on the roll using scissors. Power up the printer, fit the rolled paper into the corresponding slot, the paper is hooked and

60 60 PS TOKEN - Maintenance guide REPORT PRINTER maintenance Maintenance must be done once per month. Warning! Do not lubricate the report printer. remove the paper by turning the green knob counter clockwise open the black hatch, clean inside the hatch and the rubber cylinder, using a damp cloth and by turning the green knob. TICKET DISPENSER replacement spare part code -> 119RIR359 unplug the two connectors, behind the ticket mover Loosen the four fastening screws p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

61 PS TOKEN - Maintenance guide 61 loosen the ticket mover fastening screw use a screwdriver the remove the ticket mover TICKET DISPENSER maintenance Maintenance must be done once per month. Warning! Do not lubricate the ticket dispenser. p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice. Replacing the BARCODE FIX-SCANNER spare part code 119RIR358 use compressed air to clean the inside of the ticket mover, without dismantling it. remove the covers from the grooves

62 62 PS TOKEN - Maintenance guide loosen the four fastening screws remove the cable, connected up to the control unit p Manual code: 119GU88-EN v. 5 06/2016 CAME S.p.A. - The data and information in this manual may be changed at any time and without notice.

Ps Barcode Code Automatic parking facilities Description with barcode tickets

Ps Barcode Code Automatic parking facilities Description with barcode tickets ???Price (VAT included)??? Ps Barcode Code Automatic parking facilities Description with barcode tickets (Excl. VAT) The barcode solution for managing occasional users and payments System for managing

More information

RBM21. Access Control. Access control systems for easily managing. up to 500 users

RBM21. Access Control. Access control systems for easily managing. up to 500 users Access control systems for easily managing up to 500 users RBM21 Access Control Versatile, complete and easy to use, it is the ideal access control solution for up to 500 users It is specifically designed

More information

Unipark. Automatic parking space bar guard. Today reserving your parking space is possible.

Unipark. Automatic parking space bar guard. Today reserving your parking space is possible. Automatic parking space bar guard Unipark Today reserving your parking space is possible. The Unipark automatic bar is an innovative idea that can be applied in residential and industrial settings. It

More information

Automatic fare collection system for car park

Automatic fare collection system for car park Automatic fare collection system for car park ENTRY FEATURES - Large size display - 2D code ticket opening - 2D code ticket insert slot - Ticket request push button - Intercom call push button - Aluminium

More information

GPE4P ECONOMY PARKING SYSTEMS

GPE4P ECONOMY PARKING SYSTEMS GPE4P ECONOMY PARKING SYSTEMS PARKING SYSTEM ECONOMY Parking system designed for the collection of parking fees, suitable for both public and private car parks municipal car parks, parking at accommodation

More information

GP4P VARIANT PARKING SYSTEMS

GP4P VARIANT PARKING SYSTEMS GP4P VARIANT PARKING SYSTEMS VARIANT PARKING SYSTEM parking system designed for parking fee collection, suitable for shopping centres, parking garages, hotels, airports, hospitals, P+R car parks, etc.

More information

Automatic fare collection system for car park

Automatic fare collection system for car park Automatic fare collection system for car park ENTRY FEATURES - Large size display - Lighted plexiglass spout opening for chipcoin withdrawal - Chipcoin protected insert slot - Chipcoin request push button

More information

ACCESS CONTROL SYSTEM FA00190-EN CONFIGURATION MANUAL RBM84 - SW. English

ACCESS CONTROL SYSTEM FA00190-EN CONFIGURATION MANUAL RBM84 - SW. English ACCESS CONTROL SYSTEM FA00190-EN CONFIGURATION MANUAL RBM84 - SW EN English 2 ACCESS CONTROL SYSTEM - CONTROL SOFTWARE TOPIC SUMMARY PAGE Ch. 1 - System configuration Software installation...4 Software

More information

EL-ST100 KEYPAD CONTROLLER

EL-ST100 KEYPAD CONTROLLER WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6

More information

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Iso DIN. User Manual. 1 channel Earth Fault Monitoring Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee

More information

()*+,(*-.(/012/ /-/ 9+0:4,6+;9+)+ +*678/)+ +* 34-2 VER -63* <.5-2/9+/,+6*(=< V700E!""#$% &'

()*+,(*-.(/012/ /-/ 9+0:4,6+;9+)+ +*678/)+ +* 34-2 VER -63* <.5-2/9+/,+6*(=< V700E!#$% &' VER V700E Pag. 2 - Manual code: 119EU87 ver. 0.1 01/2009 cancelli automatici s.p.a. Pag. 3 - Manual code : 119EU87 ver. 0.1 01 / 2009 cancelli automatici s.p.a. ~ 1 1 2 2 4.4 Pag. 4 - Manual code: 119EU87

More information

Note: the wiring of the dead-man buttons has been changed since October 2001.

Note: the wiring of the dead-man buttons has been changed since October 2001. UniOP epalm10 The epalm10 is a state-of-the-art handheld HMI device with a graphic display and a keypad. The rugged polyamide enclosure offers a high level of shock and environmental resistance making

More information

WWW.DASHOU-CHINA.COM Xiamen Dashou Technology Ltd. Add.: The 2nd Floor, No. 205 Xin Feng Road, Xiamen, China 361006 Tel: 0086 592 5558660 Fax: 0086 592 5511002 Email: info@dashou-china.com www.dashou-china.com

More information

DITEC control, monitoring and safety accessories

DITEC control, monitoring and safety accessories ENG DITEC control, monitoring and safety accessories Each automation system must be equipped with control, monitoring and safety devices compatible with all the components fitted in the system and with

More information

RTD-NET Installation Instructions

RTD-NET Installation Instructions LED3 SW1 LED4 RTD-NET Installation Instructions 0V +V POWER 15-24VDC English RTD-NET Installation Instructions 100.00 RTD-NET Control Interface realtime Control Systems REMC P1 P2 RS485 D-BUS DB DA GND

More information

Single Door Standalone Access Control User Manual

Single Door Standalone Access Control User Manual Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self

More information

WWW.DASHOU-CHINA.COM Xiamen Dashou Technology Ltd. Add.: The 2nd Floor, No. 205 Xin Feng Road, Xiamen, China 361006 Tel: 0086 592 5558660 Fax: 0086 592 5511002 Email: info@dashou-china.com www.dashou-china.com

More information

With INTRATONE, you can easily secure all kinds of access points. You choose the management mode

With INTRATONE, you can easily secure all kinds of access points. You choose the management mode With INTRATONE, you can easily secure all kinds of access points (Car parks, isolated doors, pedestrian gates, etc.) You choose the management mode REAL-TIME and REMOTE USING GSM READ/WRITE MODE How does

More information

Installing Sentor. Hardware Installation

Installing Sentor. Hardware Installation Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3

More information

Lab 5: Access Control Training Station

Lab 5: Access Control Training Station Lab 5: Access Control Training Station Learning Objectives At the end of the lab, trainees should be able to: 1. Understand the functional block and hardware of an access control system. 2. Understand

More information

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM RTD-RA Installation Instructions 37.50 LEDS 4 3 2 1 D English Installation Instructions 80.00 80.00 ALL DIMENSIS IN MM C realtime Control Systems A B LEDS 4 3 2 1 D S21 J3 J6 1 2 3 4 J5 5 6 7 0V S1 0V

More information

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel

More information

Fast Safe Secure USER MANUAL. Sentinel Z18 Flap Barrier. For more Information: t: e:

Fast Safe Secure USER MANUAL. Sentinel Z18 Flap Barrier. For more Information: t: e: Fast Safe Secure USER MANUAL Sentinel Z18 Flap Barrier For more Information: t: +61 07 3205 1123 e: info@rotech.com.au www.rotech.com.au 6 Table of Contents Summary... 1. Technical Parameter... 2. Function

More information

GV-AS Controller. Installation Guide

GV-AS Controller. Installation Guide GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

Audio GSM module for modular plate

Audio GSM module for modular plate Audio GSM module for modular plate FB00758-EN PROGRAMMING MANUAL MTMA/GSM A General precautions Read the instructions carefully before beginning the installation and carry out the actions as specified

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

smartentry Wireless Video Doorphone User Manual

smartentry Wireless Video Doorphone User Manual smartentry Wireless Video Doorphone User Manual Designed & Engineered Version 1.2 in the United Kingdom Contents Precautions... 3 1. Product Overview... 4 1.1. Product Features... 4 1.2. Contents... 4

More information

ZDL-V200. Refer to Steps: 1 Thru. 4 Please Follow Wiring Steps Carefully.

ZDL-V200. Refer to Steps: 1 Thru. 4 Please Follow Wiring Steps Carefully. Box Content: - [System] - Inside Extensions - Decoder - Connector Cables - Power Supply Box Refer to Steps: 1 Thru. 4 Please Follow Wiring Steps Carefully. Support Cat5e/6 Cable Or 4-Conductor Cable Quick

More information

Suprex RS-485 SPX-7500 Wired Reader-Extender

Suprex RS-485 SPX-7500 Wired Reader-Extender Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778

More information

Parking system. Complete range of car park systems

Parking system. Complete range of car park systems Parking system Complete range of car park systems 1 The innovative technology that gives you more power An absolute innovation, and Bft exclusive, with surprising new-generation performance: U-Link is

More information

DESIGN GUIDE FOR INFINITY SYSTEMS

DESIGN GUIDE FOR INFINITY SYSTEMS Doc. 6001564 Rev B DESIGN GUIDE FOR INFINITY SYSTEMS WITH STAND ALONE OR MULTI-LINK LINK FIRMWARE TABLE OF CONTENTS 1. CABINET DIMENSIONS...3 2. WIRE CHART...3 A. CABLING TO THE MAIN PROCESSOR BOARD...

More information

GV-AS200 Controller. Hardware Installation Guide

GV-AS200 Controller. Hardware Installation Guide GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.

More information

WWW.DASHOU-CHINA.COM Xiamen Dashou Technology Ltd. Add.: The 2nd Floor, No. 205 Xin Feng Road, Xiamen, China 361006 Tel: 0086 592 5558660 Fax: 0086 592 5511002 Email: info@dashou-china.com www.dashou-china.com

More information

Creone AB Box 148 S Tranås SWEDEN Tel: +46(0) Fax: +46(0) Internet: All data

Creone AB Box 148 S Tranås SWEDEN Tel: +46(0) Fax: +46(0) Internet:   All data INSTRUCTION MANUAL Keybox 9000 Basic Keybox 9000 System Keybox 9000 Expansion KeyWin Light Creone AB Box 148 S-573 22 Tranås SWEDEN Tel: +46(0)140-38 61 80 Fax: +46(0)140-38 61 89 E-mail: mailbox@creone.com

More information

PARKY PARKY. car park management. system. Functionalism, modularity, professionalism. maximum versatility: wide range for a made-tomeasure

PARKY PARKY. car park management. system. Functionalism, modularity, professionalism. maximum versatility: wide range for a made-tomeasure PARKY Car park management system PARKY Functionalism, modularity, professionalism D831912 00002 Rev. 01 maximum versatility: wide range for a made-tomeasure car park management system high technology:

More information

Technology Security Low consumption

Technology Security Low consumption Control units Technology Security Low consumption TECHNOLOGICAL SOLUTIONS FOR SECURE OPERATION All the latest generation V2 control units can be configured via smartphone and tablet, with V2AppTool. The

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

RTD-W Installation Instructions

RTD-W Installation Instructions RTD-W Installation Instructions 0V +V POWER 15-24VDC 0V S1 S2 S3 0V S4 S5 S6 English RTD-W Installation Instructions 100.00 RTD-W Control Interface realtime Control Systems 24VAC/30VDC, 1A REMC P1 P2 RS485

More information

HI SEC Integrated Systems

HI SEC Integrated Systems Service Note 145 HI SEC Integrated Systems Subject: New S-ART 2xx Range Ref. No.: 93014501 Service Note 145 Summary: This Service Note describes a new enhanced range of S-ART s which will replace the existing

More information

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX ISC910-1-0-GB-XX ISC911-5-0-GB-XX ISC920-0-0-GB-XX ISC921-5-0-GB-XX The ImproX IXP20 is a fully featured, stand-alone Access Control System supporting up to 1 000 Tagholders and 5 000 transactions. Designed

More information

To view the last sale paid out or previous sale, select a fueling position and hold the * (asterisks, or star) button.

To view the last sale paid out or previous sale, select a fueling position and hold the * (asterisks, or star) button. EZ Config - This is the same software TMS uses to connect remotely from our factory. This a free software program that is required to program the EZ console, either with a direct connection from a PC via

More information

_ Access control SISTEMAS DE SEGURIDAD

_ Access control SISTEMAS DE SEGURIDAD _ Access control SISTEMAS DE SEGURIDAD SECURITY SYSTEMS Access control 01 Concept 02 Product 03 Characteristics 04 Compatibility 05 New functions 06 New software 07 References, accessories and diagrams

More information

Digital Speed Controller User Manual

Digital Speed Controller User Manual Diesel Engine for Generators Digital Speed Controller User Manual (DSC-1000) Ver_1.0 Doosan Infracore 페이지 1 / 36 Contents 1. Product Overview and General Specification 1.1 Product Information 1.2 Product

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-C

More information

INSTALLATION MANUAL Z-UMTS

INSTALLATION MANUAL Z-UMTS INSTALLATION MANUAL Datalogger HSPA + with built-in I/O, telecontrol functions, embedded UPS and advanced programming language EN SENECA s.r.l. Headquarters: Via Austria, 26 35127 PADOVA ITALY Phone +39.049.8705355-8705359

More information

Tel Fax: Toll free:

Tel Fax: Toll free: ELECTRONIC CONTROL UNIT (cod. 2302B Series) for swing gates automation (Mini Tank Series) C5 Accessories power supply: 24V dc Max 200 ma T1 Trimmer regulation: Operating times Open pause time Leaf delay

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated: Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact

More information

Two-door Access Controller

Two-door Access Controller Two-door Access Controller Quick Start Guide V1.0.0 Preface Overview This document elaborates on structure, installation, interface and wiring of two-door access controller. Symbol Definition The following

More information

AUTOMATION FOR SWING GATES ATI SERIES INSTALLATION MANUAL A 3024 N A 5024 N

AUTOMATION FOR SWING GATES ATI SERIES INSTALLATION MANUAL A 3024 N A 5024 N AUTOMATION FOR SWING GATES ATI SERIES INSTALLATION MANUAL A 3024 N A 5024 N IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work

More information

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details EN FULL DETAILS SKB Vandal Resistant keypad - Full Details WARNINGS Carry out the installation by carefully following the instructions provided by the manufacturer in accordance with the current standards.

More information

15P0102Q2 SINUS PENTA KEYPAD CONNECTED TO NETWORK RS485 USERS MANUAL

15P0102Q2 SINUS PENTA KEYPAD CONNECTED TO NETWORK RS485 USERS MANUAL 15P0102Q2 SINUS PENTA KEYPAD CONNECTED TO NETWORK RS485 Upd. 08/06/04 R. 00 English This manual is integrant and essential to the product. Carefully read the instructions contained herein as they provide

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

BROADEN YOUR HORIZONS

BROADEN YOUR HORIZONS Call Off Aux List Close 01:06 West Entrance BROADEN YOUR HORIZONS 7 display and advanced functions bpt.it BROADEN YOUR HORIZONS Simple and intuitive graphic interface The new era in video entry systems

More information

User Manual. Split access control with intelligent secured power supply.

User Manual. Split access control with intelligent secured power supply. User Manual Split access control with intelligent secured power supply. Contents. Introduction, features and specifications. Installation and Wiring Diagram 3. Manager Card Operation 4. User Settings 5.

More information

PSI-MODEM-SHDSL/SERIAL

PSI-MODEM-SHDSL/SERIAL PSI-MODEM-/SERIAL -SERIAL permanent line modem Data sheet 104460_en_02 PHOENIX CONTACT 2011-12-06 1 Description The industrial SERIAL permanent line modem enables broadband networking of serial devices

More information

IGLOO IGLOO EASY INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky

More information

ACTsmart2 Product Range Operating and Installation Instructions

ACTsmart2 Product Range Operating and Installation Instructions ACTsmart2 Product Range Operating and Installation Instructions 18-00045 Contents ORDERING INFORMATION......4 INSTALLATION NOTES......5 IMPORTANT......5 PRODUCT SPECIFICATION......5 30 SECOND PROGRAMMING

More information

STYLO STYLO ME - STYLO RME English EN

STYLO STYLO ME - STYLO RME English EN 119DV11EN EXTERNAL OPERATOR FOR SWING GATES Installation manual STYLO STYLO ME - STYLO RME English EN EN CAUTION! important personal safety instructions: READ CAREFULLY! Foreword This product should only

More information

Thomas. Change Machine. Operator Guide

Thomas. Change Machine. Operator Guide Thomas 5002 Change Machine Operator Guide Contents On Receiving Your New Change Machine...3 Coin Mech Installation...3 Fitting...3 Removing...3 Opening...3 Switching On...4 Machine Alarm and Alarm Keyswitch

More information

PXL-250 Tiger Controller

PXL-250 Tiger Controller PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and

More information

Installation and operation manual Z60DV-Z60DT

Installation and operation manual Z60DV-Z60DT Installation and operation manual Z60DV-Z60DT DESCRIPTION: Type Z60DV is a floor distributor unit for video door phone INFINITEPLAY. Type Z60DT is a distributor unit for entrance panel and concierge station

More information

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4 Table of Contents 1 ABOUT THIS GUIDE... 3 1.1 CONTACT INFORMATION... 3 2 ANTENNA INSTALLATION... 4 2.1 GENERAL INFORMATION... 4 2.2 SPECIFIC MOUNTING EXAMPLES... 5 2.3 CONNECTOR MOISTURE PROTECTION...

More information

SMARTLINE WIRELESS INTERFACE SYSTEM INSTALLATION MANUAL

SMARTLINE WIRELESS INTERFACE SYSTEM INSTALLATION MANUAL SMARTLINE WIRELESS INTERFACE SYSTEM INSTALLATION MANUAL SmartLine (Wireless) Installation Manual v1.9 1.Contents 2. Overview...2 Equipment List...2 Introduction... 2 Monitoring Software Compatibility...2

More information

Ellard Product Instructions

Ellard Product Instructions Ellard Product Instructions Motor Controller - V3D Maxi Stock Code Description Roundthorne Ind Est Floats Road Wythenshawe Manchester M23 9WB Tel: +44 (0) 161 945 4561 Fax: +44 (0) 161 945 4566 Iss: 1

More information

HopperOne S11 Std Pulse

HopperOne S11 Std Pulse HopperOne S11 Std Pulse Operator s manual Rev. 1.02 HopperOne S11 Std Pulse Standard / Reverse Operator s Manual 1. General description Congratulations for your purchase of the Alberici HopperOne S11!

More information

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER Table of contents 1 PRODUCT INTRODUCTION... 2 1.1 NAME AND FUNCTION OF EACH PART... 2 1.2 CABLE COLOR TABLE... 4 1.3 CABLE SELECTION... 6 2 IDENTIFYING

More information

Gladiator Lift Services Ltd OPTIO MRL Controller Specification

Gladiator Lift Services Ltd OPTIO MRL Controller Specification Gladiator Lift Services Ltd OPTIO MRL Controller Specification 1 Control System Specification General Requirements Control Cabinet A new MRL control panel shall be provided being of the enclosed steel

More information

Key Switch. Document version: 1.5 (Updated 02 May 2017)

Key Switch. Document version: 1.5 (Updated 02 May 2017) Key Switch Document version: 1.5 (Updated 02 May 2017) Contents ii Contents 1 Key Switch R10S.3... 4 2 Quick Guides...4 2.1 Controlling an Electric Lock...5 2.2 Controlling an Alarm System... 5 2.3 Controlling

More information

Micro-Ohmmeter Model 6292

Micro-Ohmmeter Model 6292 Micro-Ohmmeter Model 6292 Quick Start Guide ENGLISH www.aemc.com CHAUVIN ARNOUX GROUP Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated

More information

WIEG-EXT Wiegand to RS485 extender module.

WIEG-EXT Wiegand to RS485 extender module. WIEG-EXT Wiegand to RS485 extender module. Designed for embedding into products manufactured by third-parties, this Wiegand to RS485 extender is designed to transfer wiegand data from Access Control Card

More information

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

GSM-X. Communication module. Quick installation guide. Full manual is available on   Firmware version 1.02 gsm-x_sii_en 08/18 GSM-X Communication module Quick installation guide Full manual is available on www.satel.eu Firmware version 1.02 gsm-x_sii_en 08/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk Poland tel. +48 58

More information

MULTIWAY 2-12 WAY DOOR ENTRY SYSTEM

MULTIWAY 2-12 WAY DOOR ENTRY SYSTEM MULTIWAY 2-2 WAY DOOR ENTRY SYSTEM FTDEVM2-2 Instruction Rev0 CONTENTS Part. Product introduction. Panel(s) layout.2 Specification Part 2. Connection 2. Cable requirements 2.2 Cables and distance 2.3 Terminals

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : BS120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5. BASIC

More information

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V. ECL Apex 20 controller and ECA 20 (ECL Apex Web Panel) Description ECL Apex 20 and ECA 20 ECL Apex 20 The ECL Apex 20 and the ECA 20 (ECL Apex Web Panel) are used in large district heating applications.

More information

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS (WITH CAPACITOR CHARGER BOARD A3517-02) The process depends on Generator and System configuration. This document applies to installation of Capacitors

More information

Diamond Cabinet Slant Top Users Manual Revision 1.0

Diamond Cabinet Slant Top Users Manual Revision 1.0 Diamond Cabinet Slant Top Users Manual Revision 1.0 1 Table of Contents 1.1 Sections 1 Table of Contents...2 1.1 Sections...2 1.2 List of Figures...3 1.3 List of Tables...3 2 Revision History...5 3 Overview...6

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

Touch screen. Uses of Touch screen: Advantages of Touch screen: Disadvantages of Touch screen:

Touch screen. Uses of Touch screen: Advantages of Touch screen: Disadvantages of Touch screen: Touch screen A touch screen is the only device which works as both an input and an output device. You view the options available to you on the screen (output) and you then use your finger to touch the

More information

installation quick guide integrated access control & environmental monitoring

installation quick guide integrated access control & environmental monitoring installation quick guide integrated access control & environmental monitoring Introduction This Installation Quick Guide is suitable for standard wallmountable AX300 controllers. Illustrative technical

More information

Installation Instructions (KF-2000)

Installation Instructions (KF-2000) VERSION 2005. 10 Installation Instructions (KF-2000) Keico Hightech, Inc. Installation Instructions KF-2000 Keico Hightech Ace Twin Tower I 12 th FL 212-1, Guro-Dong, Guro-Gu Phone +82-2-853-9000 Fax +82-2-830-7809

More information

EASYVEND Series 5 CONTROL BOARD SPECIFICATION (P213)

EASYVEND Series 5 CONTROL BOARD SPECIFICATION (P213) Page 1 EASYVEND Series 5 CONTROL BOARD SPECIFICATION (P213) ISSUE B File : EasyVend Series 5 VMC Specification B.doc Changes: Issue Date Changes A 18 May 2009 Initial Release B 31 May 2009 Connector References

More information

Full Height Turnstile Manual

Full Height Turnstile Manual Full Height Turnstile Manual 1 Dear respected customers: Preface Thank you for purchasing our Full Height Turnstile. The Full Height Turnstile are available with standard electrical interface and compatible

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

High Level Lift Protocol Controller Model TS0868

High Level Lift Protocol Controller Model TS0868 High Level Lift Protocol Controller Model TS0868 High Level Lift Protocol Controller : Model TS0868 INSTALLATION GUIDE A high level lift protocol interface for the TS0869 Intelligent Four Lift Controller

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

100% electricity. Automatic transfer switch controllers ATL series

100% electricity. Automatic transfer switch controllers ATL series 100% electricity Automatic transfer switch controllers ATL series Automatic transfer switch controllers Keep control around the clock General characteristics Rated auxiliary power supply: 220-230-240VAC

More information

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad

More information

Specifications: Features:

Specifications: Features: ROFU Features: Applicable card mode EM Card / Key Fob 1 Administrator and 200 Users 200 Proximity Cards / Key fobs Access Modes:Use Bluetooth smartphone or Card / Key fob to access Built-in Tamper alarm

More information

GSM TEXT PAGER OPERATION AND INSTALLATION MANUAL 5 SIMPLE OPERATION TEST STEPS. Model: MTP4

GSM TEXT PAGER OPERATION AND INSTALLATION MANUAL 5 SIMPLE OPERATION TEST STEPS. Model: MTP4 5 SIMPLE OPERATION TEST STEPS GSM TEXT PAGER OPERATION AND INSTALLATION MANUAL 1. INSERT A GSM SIM CARD * 2. FROM YOUR MOBILE PHONE, SEND A PAIRING CODE TEXT MESSAGE TO THE PAGERS SIM CARD NUMBER. 3. LEAVE

More information

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

Token software -

Token software - Project: Token Software: v1.9.5.1 Board: CASH-Interface2 Date: 3. September 2018 SPECIFICATION: Token software - http://www.casino-software.de With the TOKEN-Package it is possible to realize a simple

More information

3700 SERIES USER MANUAL

3700 SERIES USER MANUAL SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with

More information

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information