TRANS-ATS AUTOMATIC TRANSFER SWITCH
|
|
- Neal Sparks
- 5 years ago
- Views:
Transcription
1 TRANS-ATS AUTOMATIC TRANSFER SWITCH 1. Introduction 1.1 General Specifications The unit provides the mains voltage monitoring and automatic transfer switching. In the event of a mains voltage failure, the remote start relay output is energized and the unit automatically transfers the load from the mains to the generator. Both automatic and manual control is possible. A test mode is also available which allows the generator to be run without taking the load. The unit is extensively programmable through the front panel, with password protection on two levels. Operational parameters can also be monitored and controlled from a PC via a built-in USB port. The unit monitors generator operation and gives warning of any faults that are detected. If a fault is detected, the unit shuts down the engine and shows the failure message on the LCD display. 1. Warranty EMKO Elektronik warrants that the equipment delivered is free from defects in material and workmanship. This warranty is provided for a period of two years. The warranty period starts from the delivery date. This warranty is in force if duty and responsibilities which are determined in warranty document and instruction manual performs by the customer completely. 1.3 Maintenance Repairs should only be performed by trained and specialized personnel. Cut power to the device before accessing internal parts. Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene etc.). Use of these solvents can reduce the mechanical reliability of the device. Use a cloth dampened in ethyl alcohol or water to clean the external plastic case. Introduction Brochure. ENG TRANS-ATS 1 V5 1/14
2 Ýçindekiler. Installation! Before beginning installation of this product, please read the instruction manual and warnings below carefully. A visual inspection of this product for possible damage occured during shipment is recommended before installation. It is your responsibility to ensure that qualified mechanical and electrical technicians install this product. If there is danger of serious accident resulting from a failure or defect in this unit, power off the system and seperate the electrical connection of the device from the system. Keep the power off until all of the wiring is completed so that electric shock and trouble with the unit can be prevented. Ýçindekiler.1 Configuration The unit can be programmed using the buttons and LCD display on the front panel or PC Software. Ýçindekiler. Panel Mounting The unit is designed for panel mounting. Fixing is by two screw fixings. 1- Insert the unit in the panel cut-out from the front. - Insert the fixings in the slotted at the corners of the unit and tighten the fixing screws to secure the unit against the panel.! During the equipment is putted in hole on the metal panel while mechanical installation some metal burrs can cause injury on hands, you must be careful. 15mm 135mm 9mm Figure.1 Front View 18mm Figure. Panel Cut-Out
3 .3 Electrical Connection TRANS-ATS three phase connections schematic LOAD L1 L L3 N Me c hanical i n t e rlock L1 GENERATOR L L3 MAINS L1 L L3 N N! Elect r ical interlock FUSE-6 FUSE-5 FUSE-4 G M FUSE-3 FUSE- FUSE Max. 3 Max. 3 8A Generator Contactor Relay Mains Contactor Relay 8A USB TRANSISTOR OUTPUTS MAX. 1 A BATTERY + 5A 5A FUSE-7 FUSE-8 BATTERY - BATTERY + Configurable Output-1 Configurable Output- Configurable Output-3 Configurable Output-4 BATTERY + Configurable Output-5 Remote Start or Configurable Output-6 1! BATTERY - Emergency Stop or Configurable Input-1 Mains Break. Feedback or Configurable Input- Gen. Break. Feedback or Configurable Input-3 Configurable Input-4 Configurable Input-5 Configurable Input-6 Configurable Input-7 Generator Ready or Configurable Input-8 BATTERY + FUSE-1, FUSE-, FUSE-5, FUSE-6 A. T FUSE-7 6 A. T FUSE-8 Max. 1 A. T FUSE-3, FUSE-4 8 A. T! 1- Connect the unit as shown in the appropriate diagram. Be sure to connect the battery supply the right way round and battery negative should be grounded. - Current transformers secondary should be grounded. 3
4 3. Changing And Saving Parameters Values Operation Screen MAINS V1: 38V V1: V V3: 38V V: V V31: 38V V3: V Mains okay When the Prog button is pressed, the parameters section is asked for accessing to parameters. PROGRAM Operator setting Technician setting Factory adjustment Press the Up or Down buttons to select the section you wish to view/change. PROGRAM Operator setting Technician setting Factory adjustment Press the Enter button. TECHNICIAN SETTING Password Enter password with cursor (Right, Left, Up and Down) buttons. TECHNICIAN SETTING Password 16 Note1: If Enter button is pressed and the technician password is zero, Password screen is ignored. TECHNICIAN SETTING System Mains Generator Power supply Press the Enter button to confirm password. If the password is incorrect, the unit will drop out of program mode. Press the Up or Down buttons to select the main parameter group you wish to view/change. TECHNICIAN SETTING System Mains Generator Power supply GENERATOR Volt level Frequency level Current level & act. Power level Press Enter button to access to all parameters page in currently main parameter group. Press Enter button to access to all parameters in currently parameter page. GENERATOR VOLT LEVEL Under volt shutdown Under volt prealarm Under volt reset Over volt shutdown GENERATOR VOLT LEVEL Under volt shutdown 3 Vac Parameter can be changed with Up and Down buttons. Press the Enter button to view parameter value. GENERATOR VOLT LEVEL Under volt shutdown 35 Vac GENERATOR Volt level Frequency level Current level & act. Power level Press Enter button to confirm the changed value. When the Escape button is pressed any time, previous page can be accessed. GENERATOR VOLT LEVEL Under volt shutdown Under volt prealarm Under volt reset Over volt shutdown To exit from programming mode any time, press Prog button. MAINS V1: 38V V1: V V3: 38V V: V V31: 38V V3: V Mains okay Operation Screen 4
5 4. Parameters 4.1 Operator Parameters Mains MAINS VOLT LEVEL (Mains->Volt level) Under volt trip Mains Under Voltage Under volt reset Mains Under Voltage Reset Over volt trip Mains Over Voltage Over volt reset Mains Over Voltage Reset Max MAINS FREQ. LEVEL (Mains->Frequency level) Under freq trip Mains Under Frequency Under freq reset Mains Under Frequency Reset Over freq trip Mains Over Frequency Over freq reset Mains Over Frequency Reset Max Generator GENERATOR VOLT LEVEL (Generator->Volt level) Under volt shutdown Generator Under Voltage Shutdown Under volt prealarm Generator Under Voltage Pre-Alarm Under volt reset Generator Under Voltage Pre-Alarm Reset Over volt shutdown Generator Over Voltage Shutdown Over volt prealarm Generator Over Voltage Pre-Alarm Over volt reset Generator Over Voltage Pre-Alarm Reset Shutdown delay time Generator Voltage Shutdown Delay Time Max 6(dis) 6 3 6(dis) (dis) GENERATOR FREQ LEVEL (Generator->Frequency level) Max Under freq shutdown Generator Under Frequency Shutdown 3.(dis) Under freq prealarm Generator Under Frequency Pre-Alarm 3.(dis) Under freq reset Over freq shutdown Over freq prealarm Over freq reset Generator Under Frequency Pre-Alarm Reset Generator Over Frequency Shutdown Generator Over Frequency Pre-Alarm Generator Over Frequency Pre-Alarm Reset 3. 3.(dis) 3.(dis) Shutdown delay time Generator Frequency Shutdown Delay Time GENERATOR CUR LEVEL (Generator->Current level) Under cur. set Under cur. prealarm Under cur. reset Over cur. set Over cur. prealarm Over cur. reset Generator Under Current Set Generator Under Current Pre-Alarm Generator Under Current Pre-Alarm Reset Generator Over Current Set Generator Over Current Pre-Alarm Generator Over Current Pre-Alarm Reset Max 1 A (dis) dis A 5 A A (dis) 999 A 998 A Note: dis = disable 5
6 GEN POWER LEVEL (Generator->Power level) Under power shutdown Under power prealarm Under power reset Over power shutdown Over power prealarm Over power reset Shutdown delay time Reverse power set Generator Under Power Shutdown Generator Under Power Pre-Alarm Generator Under Power Pre-Alarm Reset Generator Over Power Shutdown Generator Over Power Pre-Alarm Generator Over Power Pre-Alarm Reset Generator Power Shutdown Delay Time Reverse Power Set (dis) (dis) (dis) (dis) - Max 99 dis dis 5 dis dis kw GEN WORKING CALENDAR (Generator->Working calendar) Disable/enable select Working Calendar Disable or Enable Start time on monday Working Calendar Work Start Time on Monday Stop time on monday Working Calendar Work Stop Time on Monday Start time on tues. Stop time on tuesday Start time on wednes. Stop time on wednes. Start time on thurs. Stop time on thursday Start time on friday Stop time on friday Start time on satur. Stop time on saturday Start time on sunday Stop time on sunday Working Calendar Work Start Time on Tuesday Working Calendar Work Stop Time on Tuesday Working Calendar Work Start Time on Wednesday Working Calendar Work Stop Time on Wednesday Working Calendar Work Start Time on Thursday Working Calendar Work Stop Time on Thursday Working Calendar Work Start Time on Friday Working Calendar Work Stop Time on Friday Working Calendar Work Start Time on Saturday Working Calendar Work Stop Time on Saturday Working Calendar Work Start Time on Sunday Working Calendar Work Stop Time on Sunday Max /ENABL Technician Parameters 4..1 System SYSTEM NETWORK (System->Network) CT ratio Current Transformer Ratio PT ratio Voltage Transformer Ratio Type of AC system Phase sequence Generator rating Select AC system; Generator Phase Sequence (dis, L13 or L31) Generator rating set - 1 Phase Wire 1-3 Phase 4 Wire - Phase 3 Wire L1-L 3- Phase 3 Wire L1-L3 Max , L13, L31 3 Note: dis = disable 6
7 BREAKERS (System->Breakers) Type of Breaker Gen.brk.cls.contact Gen.brk.cls.relay Gen.brk.cls.time Gen.brk.open relay Gen.brk.open time Mains.brk.cls.contact Mains.brk.cls.relay Mains.brk.cls.time Mains.brk.open relay Mains.brk.open time Break.close puls.time Break.open pulse time Transfer time Spring loading time Retry number Hardware Breaker Selection Gen Close Breaker Contact Type Gen Close Breaker Relay Type Gen Close Timer Gen Open Breaker Relay Type Gen Open Timer Mains Close Breaker Contact Type Mains Close Breaker Relay Type Mains Close Timer Mains Open Breaker Relay Type Mains Open Timer Breaker Close Pulse Time Breaker Open Pulse Time Transfer Time Spring Loading Time Retry Number LCD DISPLAY (System->LCD display) Language Language Selection Contrast Contrast Setting Auto backlight off Auto Backlight Off Auto scroll time Auto Scroll Time Auto scroll number * 1 Auto Scroll Number Err. mesg scroll time Scroll Time For Error Messages Max NO / NC NOR / PULS NOR / PULS NO / NC NOR / PULS NOR / PULS Max ENGLISH/CHINESE ENGLISH ENABL/ (dis) COMMUNICATION (System->Communication) Max Slave address Slave Address Baud rate Parity Baud Rate: - 1 baud 1-4 baud - 48 baud 3-96 baud 4-19 baud baud Parity: - NONE ODD - EVEN Stop bit Stop Bit (-> 1 stop bit,1-> stop bit) 1 DATE & TIME SET (System->Date & time set) Year Month Year Month Day Week Hour ute ond Max Date 1 31 Day of week 1 7 Hour 3 ute 59 ond 59 Note: * 1 = Maximum value of this parameter is 4 at TRANS-AMF.CN device. NO / NC : Normally Open / Normally Close NOR / PULS : Normal / Pulse 7
8 DEFAULT SETTINGS (System-> settings) Save setting to def. Save setting to default Reset default sets Reset default sets Reset factory sets Reset factory sets PASSWORD SETTINGS (System->Password settings) Operator password Operator Password Technician password Technician Password Max YES / NO NO YES / NO NO YES / NO NO Max 4.. Mains MAINS VOLT LEVEL (Mains->Volt level) Under volt trip Mains Under Voltage Under volt reset Mains Under Voltage Reset Over volt trip Mains Over Voltage Over volt reset Mains Over Voltage Reset Max MAINS FREQ. LEVEL (Mains->Frequency level) Under freq trip Mains Under Frequency Under freq reset Mains Under Frequency Reset Over freq trip Mains Over Frequency Over freq reset Mains Over Frequency Reset Max MAINS ACTIONS (Mains->Actions) Mains failure detect Mains Failure Detection En/Dis Mains fail.stop mode Look Mains Failure at Stop Mode En/Dis Always return delay Always Look Mains Return Delay Max ENABL/ ENABL ENABL/ ENABL ENABL/ 4..3 Generator GENERATOR VOLT LEVEL (Generator->Volt level) Under volt shutdown Generator Under Voltage Shutdown Under volt prealarm Generator Under Voltage Pre-Alarm Under volt reset Generator Under Voltage Pre-Alarm Reset Over volt shutdown Generator Over Voltage Shutdown Over volt prealarm Generator Over Voltage Pre-Alarm Over volt reset Generator Over Voltage Pre-Alarm Reset Shutdown delay time Generator Voltage Shutdown Delay Time Max 6(dis) 6 3 6(dis) (dis) GENERATOR FREQ LEVEL (Generator->Frequency level) Max Under freq shutdown Generator Under Frequency Shutdown 3.(dis) Under freq prealarm Generator Under Frequency Pre-Alarm 3.(dis) Under freq reset Over freq shutdown Over freq prealarm Over freq reset Generator Under Frequency Pre-Alarm Reset Generator Over Frequency Shutdown Generator Over Frequency Pre-Alarm Generator Over Frequency Pre-Alarm Reset 3. 3.(dis) 3.(dis) Shutdown delay time Generator Frequency Shutdown Delay Time Note: dis = disable 8
9 GEN CUR LEVEL & ACT (Generator->Current level & act.) Under cur. set Generator Under Current Set Under cur. prealarm Generator Under Current Pre-Alarm Under cur. reset Generator Under Current Pre-Alarm Reset Under cur. act. Generator Under Current Actions - Disable 1 - Warning (Alarm Only, No Shutdown) - Electrical Trip (Alarm/Off Load Generator Followed By Shutdown After Cooling) 3 - Shutdown (Alarm And Shutdown) Under act. delay time Over cur. set Over cur. prealarm Over cur. reset Over cur. act. Over act. delay time Short circuit cur. Generator Under Current Actions Delay Time Generator Over Current Set Generator Over Current Pre-Alarm Generator Over Current Pre-Alarm Reset Generator Over Current Actions - Disable 1 - Warning (Alarm Only, No Shutdown) - Electrical Trip (Alarm/Off Load Generator Followed By Shutdown After Cooling) 3 - Shutdown (Alarm And Shutdown) Generator Over Current Actions Delay Time Generator Short Circuit Current Set Max 1 (dis) dis 5 (dis) 3 dis 99 (dis) (dis) dis A A A A A A A GEN POWER LEVEL (Generator->Power level) Under power shutdown Under power prealarm Under power reset Over power shutdown Over power prealarm Over power reset Shutdown delay time Reverse power set Reverse power act. Rv.pow.act.delay time Generator Under Power Shutdown Generator Under Power Pre-Alarm Generator Under Power Pre-Alarm Reset Generator Over Power Shutdown Generator Over Power Pre-Alarm Generator Over Power Pre-Alarm Reset Generator Power Shutdown Delay Time Reverse Power Set Reverse Power Actions - Disable 1 - Warning (Alarm Only, No Shutdown) - Electrical Trip (Alarm/Off Load Generator Followed By Shutdown After Cooling) 3 - Shutdown (Alarm And Shutdown) Reverse Power Action Delay Time (dis) (dis) (dis) (dis) - (dis) Max dis dis 5 dis dis (dis) kw 9
10 GEN WORKING CALENDAR (Generator->Working calendar) Disable/enable select Working Calendar Disable or Enable Start time on monday Working Calendar Work Start Time on Monday Stop time on monday Working Calendar Work Stop Time on Monday Start time on tues. Stop time on tuesday Start time on wednes. Stop time on wednes. Start time on thurs. Stop time on thursday Start time on friday Stop time on friday Start time on satur. Stop time on saturday Start time on sunday Stop time on sunday Working Calendar Work Start Time on Tuesday Working Calendar Work Stop Time on Tuesday Working Calendar Work Start Time on Wednesday Working Calendar Work Stop Time on Wednesday Working Calendar Work Start Time on Thursday Working Calendar Work Stop Time on Thursday Working Calendar Work Start Time on Friday Working Calendar Work Stop Time on Friday Working Calendar Work Start Time on Saturday Working Calendar Work Stop Time on Saturday Working Calendar Work Start Time on Sunday Working Calendar Work Stop Time on Sunday Max /ENABL GENERATOR GENERAL (Generator->General) Max Sens.option gen.freq Sensing Options Generator Frq En/Dis ENABL/ ENABL All warning are latch All Warnings Are Latched En/Dis ENABL/ 4..4 Power Supply ENGINE PLANT BATTERY (Engine->Plant battery) Max Under volt Battery Undervolts Warning 6.(dis) Under volt reset Battery Undervolts Warning Reset Under volt delay Battery Undervolts Volts Delay Over volt Battery Overvolts Warning 6.(dis) Over volt reset Battery Overvolts Warning Reset Over volt delay Battery Overvolts Delay Engine LOAD TEST (Engine->Load test) Max Disable/enable select Disable, No Load or On Load Selection -DISABLE 1-NO LOAD -ON LOAD 1-NO LOAD EXERCISE (Engine->Exercise) Time of Period Week Start time Generator exercise working period on related day Generator exercise working day of week Generator exercise work start time on related day Max (dis) 99 dis ENGINE GENERAL (Engine->General) Engine running volt Engine Running Voltage Engine running freq. Engine Running Frequency Max 6(dis)
11 4..6 Inputs CONF. INPUT-X (Inputs->Conf. input-x) Dis,user conf.or list - Disable 1- User Configured - Select From List Indication Activation Select from list - Normally Open (Close To Activate) If User Configured - Status 1- Warning Non-Latching - Warning Latching 3- Electrical Trip 4- Shutdown If User Configured - Active From Starting 1- Active From Safety On - Always Active If Select From List -Remote Start On Load 1-Remote Start Off Load -Auxiliary Mains Fail 3-Simulate Lamp Test Button 4-Simulate Horn Reset Button 5-Simulate Alarm Reset Button 6-Simulate Auto Button 7-Simulate Test Button 8-Simulate Manual Button 9-Simulate Start Button 1-Simulate Stop Button 11-Generator Closed Auxiliary 1-Generator Load Inhibit 13-Mains Closed Auxiliary 14-Mains Load Inhibit 15-Auto Restore Inhibit 16-Auto Start Inhibit 17-Panel Lock 18-Scheduled Runs(Exercise) Inhibited 19-Reserved -Transfer To Generator/Open Mains 1-Transfer To Mains/Open Generator -Remote Inhibit 3-Engine Running 4-Generator available 5 - Emergency Stop (for only input-1) Max in1= (dis) in, 3= in4, 5= in6, 7= in8= 1 in1, 3=1 in, 4= in5, 6= in7, 8= 4 in1= in= in3=4 in4= in5= in6= in7= in8= in1, = in3, 4= in5, 6= in7, 8= in1=5 in=4 in3=4 in4=4 in5=4 in6=4 in7=4 in8=4 in1=5 in=13 In3=11 in4=19 in5=3 in6=7 in7=3 in8=4 Active delay Input active delay 5 in1= in, 3, 4=1 in5, 6, 7=1 In8=1 Note-1 : x = 1(input-1), (input-), 3(input-3), 4(input-4), 5(input-5), 6(input-6), 7(input-7) or 8(input-8) Note- : 5 - Emergency Stop (for only input-1) Note-3 : dis = disable 11
12 CONF. EXP. INPUT-X (Inputs->Conf. exp. input-x) Dis,user conf.or list - Disable 1- User Configured - Select From List Hardware type Indication Activation Select from list Active delay -> -Ve (Switched To Battery -) 1-> +Ve (Switched To Battery +) - Normally Open (Close To Activate) If User Configured - Status 1- Warning Non-Latching - Warning Latching 3- Electrical Trip 4- Shutdown If User Configured - Active From Starting 1- Active From Safety On - Always Active If Select From List -Auxiliary Mains Fail 3-Simulate Lamp Test Button 4-Simulate Horn Reset Button 5-Simulate Alarm Reset Button 6-Simulate Auto Button 7-Simulate Test Button 8-Simulate Manual Button 9-Simulate Start Button 1-Simulate Stop Button 11-Generator Closed Auxiliary 1-Generator Load Inhibit 13-Mains Closed Auxiliary 14-Mains Load Inhibit 15-Auto Restore Inhibit 16-Auto Start Inhibit 17-Panel Lock 18-Scheduled Runs Inhibited 19-Reserved -Transfer To Generator/Open Mains 1-Transfer To Mains/Open Generator Input active delay Max (dis) Note-1 : x = 1(exp. input -1), (exp. input -), 3(exp. input -3), 4(exp. input -4), 5(exp. input -5), 6(exp. input -6), 7(exp. input -7) or 8(exp. input -8) Note- : dis = disable 1
13 4..7 Outputs CONF. OUTPUT-1 (Outputs->Conf. output-1) - Normally Open (Close To Activate) -NOT USED 1-AIR FLAP CONTROL -ALARM RESET 3-AUDIBLE ALARM 4-AUTO START INHIBIT 5-AUXILIARY MAINS FAILURE 6-BATTERY HIGH VOLTAGE 7-BATTERY LOW VOLTAGE 8-CALLING FOR SCHEDULED RUN(EXERCISE) 9-RESERVED 1-RESERVED 11-RESERVED 1-COMMON ALARM 13-COMMON ELECTRICAL TRIP ALARM 14-COMMON SHUTDOWN ALARM 15-COMMON WARNING ALARM 16-COOLING FAN AFTER START 17-COOLING FAN AFTER STOP 18-RESERVED 19-RESERVED -COOLING DOWN TIMER IN PROGRESS 1-RESERVED -DELAYED ALARMS ACTIVE 3-DIGITAL INPUT1 ALARM 4-DIGITAL INPUT ALARM 5-DIGITAL INPUT3 ALARM 6-DIGITAL INPUT4 ALARM 7-DIGITAL INPUT5 ALARM 8-DIGITAL INPUT6 ALARM 9-DIGITAL INPUT7 ALARM 3-EXPANSION INPUT1 ALARM 31-EXPANSION INPUT ALARM 3-EXPANSION INPUT3 ALARM 33-EXPANSION INPUT4 ALARM 34-EXPANSION INPUT5 ALARM 35-EXPANSION INPUT6 ALARM 36-EXPANSION INPUT7 ALARM 37-EXPANSION INPUT8 ALARM 38-DIGITAL INPUT8 ALARM 39-EMERGENCY STOP 4-FAIL TO START ALARM 41-FAIL TO STOP ALARM 4-RESERVED 43-RESERVED 44-RESERVED 45-GENERATOR AT REST 46-GENERATOR AVAILABLE 47-GENERATOR CLOSED AUXILIARY 48-GENERATOR FAILED TO CLOSE 49-GENERATOR FAILED TO OPEN 5-GENERATOR HIGH FREQUENCY PRE-ALARM 51-GENERATOR HIGH FREQUENCY SHUTDOWN 5-GENERATOR HIGH VOLTAGE PRE-ALARM 53-GENERATOR HIGH VOLTAGE SHUTDOWN 54-GENERATOR LOAD INHIBIT 55-GENERATOR LOW FREQUENCY PRE-ALARM 56-GENERATOR LOW FREQUENCY SHUTDOWN 57-GENERATOR LOW VOLTAGE PRE-ALARM 58-GENERATOR LOW VOLTAGE SHUTDOWN 59-GENERATOR STOPPING 6-GENERATOR OPEN BREAKER 61-HORN OUTPUT LATCHED 6-HORN OUTPUT PULSED 63-LAMP TEST 64-RESERVED 65-RESERVED 66-RESERVED 67-RESERVED 68-MAINS CLOSED AUXILIARY 69-MAINS FAILED TO CLOSE 7-MAINS FAILED TO OPEN 71-MAINS FAILURE 7-MAINS HIGH FREQUENCY 73-MAINS HIGH VOLTAGE 74-MAINS LOAD INHIBIT 75-MAINS LOW FREQUENCY 76-MAINS LOW VOLTAGE 77-MAINS OPEN BREAKER 78-NO LOADING COMMAND 79-RESERVED 8-RESERVED 81-RESERVED 8-RESERVED 83-OVER CURRENT PRE-ALARM 84-OVER CURRENT 85-OVER POWER PRE-ALARM 86-OVER POWER SHUTDOWN 87-RESERVED 88-RESERVED 89-PANEL LOCK 9-RESERVED 91-RESERVED 9-RESERVED 93-RESERVED 94-REMOTE START PRESENT 95-RESERVED 96-SHORT CIRCUIT 97-RESERVED 98-RESERVED 99-STARTING ALARMS ARMED 1-RESERVED 11-SYSTEM IN AUTO MODE 1-SYSTEM IN MANUAL MODE 13-SYSTEM IN STOP MODE 14-SYSTEM IN TEST MODE 15-UNDER CURRENT PRE-ALARM 16-UNDER CURRENT 17-UNDER POWER PRE-ALARM 18-UNDER POWER SHUTDOWN 19-RESERVED 11-RESERVED 111-WAITING FOR GENERATOR 11-RESERVED 113-LOAD SUPPLY FROM GENERATOR 114-LOAD SUPPLY FROM MAINS 115-RESERVED 116-RESERVED 117-RESERVED 118-RESERVED 119-RESERVED 1-RESERVED 11-RESERVED 1-REMOTE CONTROL ACTIVE 13-REVERSE POWER 14-RESERVED 15-RESERVED 16-RESERVED 17-RESERVED 18-RESERVED 19-REMOTE OUTPUT Max
14 CONF. OUTPUT- (Outputs->Conf. output-) - Normally Open (Close To Activate) Max CONF. OUTPUT-3 (Outputs->Conf. output-3) - Normally Open (Close To Activate) Max CONF. OUTPUT-4 (Outputs->Conf. output-4) - Normally Open (Close To Activate) Max CONF. OUTPUT-5 (Outputs->Conf. output-5) - Normally Open (Close To Activate) Max CONF. OUTPUT-6 (Outputs->Conf. output-6) - Normally Open (Close To Activate) Max CONF. EXP. OUTPUT-1 (Outputs->Conf. exp. output-1) - Normally Open (Close To Activate) Max CONF. EXP. OUTPUT- (Outputs->Conf. exp. output-) - Normally Open (Close To Activate) Max CONF. EXP. OUTPUT-3 (Outputs->Conf. exp. output-3) - Normally Open (Close To Activate) Max CONF. EXP. OUTPUT-4 (Outputs->Conf. exp. output-4) - Normally Open (Close To Activate) Max CONF. EXP. OUTPUT-5 (Outputs->Conf. exp. output-5) - Normally Open (Close To Activate) Max CONF. EXP. OUTPUT-6 (Outputs->Conf. exp. output-6) - Normally Open (Close To Activate) Max
15 CONF. EXP. OUTPUT-7 (Outputs->Conf. exp. output-7) - Normally Open (Close To Activate) Max CONF. EXP. OUTPUT-8 (Outputs->Conf. exp. output-8) - Normally Open (Close To Activate) Max Timers START TIMERS (Timers->Start timers) Max Mains transient delay Mains Transient Delay... Mains fail start dely Mains Fail Start Delay Remote start delay Remote Start Delay 36 4 Generator fail delay Generator fail delay 5 45 Safety on delay Safety On Delay 99 5 Warming up time Warmup Time 5 3 Horn duration Horn Duration (dis) STOPPING TIMERS (Timers->Stopping timers) Max Mains return delay Mains Return Delay 36 5 Remote stop delay Remote Stop Delay 5 4 Cooling time Cooling Time (dis) 36 6 Fail to stop delay Fail To Stop Time Expansion Modules IO (1-8) MODULE (Expansion modules->io (1-8)) Disable/enable select Expansion I/O Module Selection CAN fault actions Can Fault Actions: - Disable 1- Warning Non-Latching - Warning (Alarm Only, No Shutdown) 3- Electrical Trip (Alarm/Off Load Generator Followed By Shutdown After Cooling) 4- Shutdown (Alarm And Shutdown) Max ENABL/ (dis) 4 CAN fault activation Can Fault Activation: - Active From Starting 1- Active From Safety On - Always Active CAN fault delay Can Fault Delay 5 1 DIAL-UP & ETHERNET (Expansion modules-> Dial-up & Ethernet) Max Disable/enable select Expansion Dal-up&Ethernet Module Selection ENABL/ Call back selection Call Back Selection ENABL/ Note: dis = disable cont = continuous 15
16 GSM MODULE (Expansion modules->gsm) Disable/enable select Expansion GSM Module Selection Call back selection Call Back Selection SMS SMS Feature Enable or Disable Max ENABL/ ENABL/ ENABL/ GPRS MODULE (Expansion modules->gprs) Disable/enable select Expansion GPRS Module Selection Call back selection Call Back Selection Max ENABL/ ENABL/ WEB SERVER MODULE (Expansion modules->web Server Disable/enable select Web Server Module Selection Max ENABL/ 4..1 User Adjustment MAINS VOLTAGE OFFSET (User adjustment->mains voltage offset) Mains V1 offset Mains V offset Mains V3 offset Mains V1 Offset Mains V Offset Mains V3 Offset GEN. VOLTAGE OFFSET (User adjustment->gen. voltage offset) Gen. V1 offset Gen. V offset Gen. V3 offset Generator V1 Offset Generator V Offset Generator V3 Offset CURRENT OFFSET (User adjustment->current offset) Current I1 offset Current I offset Current I3 offset Current I1 Offset Current I Offset Current I3 Offset Max Max Max - A - A - A BATTERY OFFSET (User adjustment->battery offset) Max Batt.volt offset Battery Voltage Offset Note: dis = disable 16
17 5. Specifications Equipment use Housing & Mounting Panel Cut-Out Protection Weight Environmental rating Operating/Storage Temperature Operating/Storage Humidity Installation Over Volt. Category Pollution Degree Mode of Operation DC Battery Supply Voltage Cranking Dropouts : Electrical control equipment for generating sets. : 9 mm x 15 mm x 41 mm. (including connectors). Plastic housing for panel mounting. : 18mm x 135mm. : IP65 at front panel. : Approximately,53 Kg. : Standard, indoor at an altitude of less then meters with non-condensing humidity. : - C to +7 C / -3 C to +8 C : 9 % max. (non-condensing) : II Appliances, portable equipment : II, Normal office or workplace, non conductive pollution : Continuous. : 8 to 3 V. Max. operating current is 36 ma. : Battery voltage can be VDC for max. 5 ms during cranking (battery voltage should be at least nominal voltage before cranking). Battery Voltage Measurement Mains Voltage Measurement Mains Frequency : 8 to 3 V, accuracy: 1 % FS, resolution:,1 V : 3 to 3 VAC Ph-N, 5 to Accuracy: 1 % FS, Resolution: 1 V. : 5 to 99.9 (min. VAC Ph-N) Accuracy:,5 % FS, Resolution:,1. Generator Voltage Measurement : 3 to 3 VAC Ph-N, 5 to Accuracy: 1 % FS, Resolution: 1 V. Generator Frequency : 5 to 99.9 (min. VAC Ph-N) Accuracy:,5 % FS, Resolution:,1. CT secondary : 5A. Communication interface : USB programming and communication port. Optional Expansion I/O Module : Expansion I/O module including 8 inputs and 8 outputs. Optional Comm. Modules : Ethernet/Dial-up, GSM/GPRS and Web Server modules. Relay Outputs : Generator contactor relay output 8A@5 Mains contactor relay output 8A@5 Configurable output-5 5A@5 Configurable output-6 5A@5 Transistor Outputs : Configurable output-1 1A at DC supply voltage Configurable output- 1A at DC supply voltage Configurable output-3 1A at DC supply voltage Configurable output-4 1A at DC supply voltage All transistor ouputs supplied from DC supply terminal 17
18 6. Other Informations Manufacturer Information: Emko Elektronik Sanayi ve Ticaret A.Þ. Demirtaþ Organize Sanayi Bölgesi Karanfil Sk. No: BURSA/TURKEY Phone : Fax : Repair and maintenance service information: Emko Elektronik Sanayi ve Ticaret A.Þ. Demirtaþ Organize Sanayi Bölgesi Karanfil Sk. No: BURSA/TURKEY Phone : Fax : Your Technology Partner Thank you very much for your preference to use Emko Elektronik products, please visit our web page to download detailed user manual. 18
TRANS-ATS AUTOMATIC TRANSFER SWITCH User Manual
TRANS-ATS AUTOMATIC TRANSFER SWITCH User Manual EMKO ELEKTRONÝK A. Þ. Demirta þ Org. San. Bolg. Karanfil Sk. No: 6 TR 16369 Bursa / TURKEY Phone Faks Url E-mail : +9 4 61 19 : +9 4 61 191 : www.emkoelektronik.com.tr
More informationTRANS-MINIAMF AUTOMATIC MAINS FAILURE UNIT
1.Introduction 1.1 General Specifications TRANS-MINIAMF MATIC MAINS FAILURE UNIT The unit provides for automatic transfer of a load from mains to generator in the event of a mains failure. Intended for
More informationTRANS-MAINS SYNCHRONISING & AUTOMATIC TRANSFER SWITCH
TRANS-MAINS SYNCHRONISING & AUTOMATIC TRANSFER SWITCH. Introduction. General Specifications TRANS-MAINS is a mains control, synchronising and automatic transfer unit. The unit is designed to synchronise
More informationTRANS-MINIAUTO AUTOMATIC START UNIT
TRANS-MINI MATIC START UNIT 1.Introduction 1.1 General Specifications The unit provides automatic start and stop the engine and protect the generator system. Both automatic and manual control is possible.
More informationESM-3711-CL 77 x 35 DIN Size, Minimum & Maximum Temperature Record, Digital, ON / OFF Cooling Controller
ESM-3711-CL 77x35 DIN Size Cooling Controller Internal Buzzer ESM-3711-CL 77 x 35 DIN Size, imum & imum Temperature Record, Digital, ON / OFF Cooling Controller - 3 Digits display - NTC input or, PTC input
More informationESM H 77x35 DIN Size Heating Controller Digital, ON / OFF Temperature Controller
Internal Buzzer ESM- 3711-H 77x35 DIN Size Heating Controller ESM-3711-H 77 x 35 DIN Size Digital, ON / OFF Temperature Controller - 3 Digits display - PTC Input or, J type Thermocouple Input or, K type
More informationEPM x35 DIN Size Control Panel For V/F Speed Controller
EM-3790 77x35 DIN Size Control anel For V/F Speed Controller EM-3790 77 x 35 DIN Size Control anel For V/F Speed Controller - 4 Digits Display - Easily adjustable set value from front panel - Configurable
More informationINSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:
DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated
More informationATS CONTROLLER OPERATING MANUAL
HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER OPERATING MANUAL Smartgen Electronic CONTENT 1 SUMMARY... 4 2 PERFORMANCE AND CHARACTERISTICS... 4 3 SPECIFICATION... 5 4 OPERATING... 6 4.1
More informationHAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL
HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD CONTENT 1 OVERVIEW... 5 2 PERFORMANCE AND CHARACTERISTICS... 6 3 SPECIFICATION... 8 4 OPERATING...
More informationDEEP SEA ELECTRONICS PLC DSE334 Configuration Suite Software Manual
DEEP SEA ELECTRONICS PLC DSE334 Configuration Suite Software Manual Document Number 057-156 Author: Paul Gibbons DSE334 Configuration Suite Software Manual ISSUE 1 DSE334 Configuration Suite Software Manual
More informationHAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL
HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co.,
More informationDM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER
DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is
More informationHGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology
HGM9580 Bus Tie Bus Parallel Unit USER MANUAL Smartgen Technology This manual is suitable for HGM9580 bus tie bus parallel unit only. Clarification of notation used within this publication. SIGN INSTRUCTION
More informationQuick Start Guide TS A
Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer
More informationTRANS-SYNCRO SYNCHRONISING & LOAD SHARING UNIT FOR GAS/DIESEL/GASOLINE GENERATORS WITH J1939 ECUs User Manual
TRANS-SYNCRO SYNCHRONISING LOAD SHARING UNIT FOR GAS/DIESEL/GASOLINE GENERATORS WITH J1939 ECUs User Manual EMKO ELEKTRONÝK A.Þ. Demirtaþ Org. San. Bolg. Karanfil Sk. No: 6 TR 16369 Bursa / TURKEY Phone
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE705 ATS CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More informationModel P4470 Save A Watt Operation Manual
Model P4470 Save A Watt Operation Manual Thank you for purchasing the P4470 Save A Watt. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation,
More informationTime Mark Corporation Model 42A Pump Controller User s Guide
Time Mark Corporation Model 42A Pump Controller User s Guide Graphic display User friendly Expandable Communications capable 2009 Time Mark Corporation. All rights reserved. Made in the U.S.A. Time Mark
More informationHITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions
HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction
More informationEZM x72 DIN SIZE Programmable Counter. EZM x 72 DIN Size Universal Input Programmable Counter
EZM-7730 72x72 DIN SIZE rogrammable Counter EZM-7730 72 x 72 DIN Size Universal Input rogrammable Counter - 6 digits rocess (V) and 6 digits Set (SV) Value Display - Operation with 1 Set Value - Reset,
More informationCM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL
CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
More informationINSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers
2010-12-10 5011699201-PBB1 Eaton Logic Controller ELCB Controllers INSTRUCTION SHEET [Applicable Controllers] ELCB-PB10 ELCB-PB14 ELCB-PB20 ELCB-PB30 ELCB-PB40 IL05001005E 002-1310020-02 Thank you for
More informationACCESS 9340/9360 Meter Input/Output Module
Installation Manual PMIM-IOMOD-0208 ACCESS 9340/9360 Meter Input/Output Module 9340-60-I/O2222 and 9340-60-I/O26 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the
More informationOwner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español
Owner's Manual True RMS Multimeter Model No. 82023 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español
More informationSOLARIMMERSION IV Advanced Installation Manual v1.9
SOLARIMMERSION IV Advanced Installation Manual v1.9 1 Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation
More informationESM x 96 1/4 DIN Temperature Controller with Universal Input
ESM-9920 96x96 1/4 DIN Temperature Controller ESM-9920 96 x 96 1/4 DIN Temperature Controller with Universal Input - 4 digits process(v) and 4 digits process set value(sv) display - Universal process input
More informationTT /12b INSTALLATION INSTRUCTIONS. Introduction
TT-1545 11/12b INSTALLATION INSTRUCTIONS Original Issue Date: 6/10 Model: 20-300 kw Generator Sets Market: Industrial Subject: Decision-Maker 3000 Controller Service Replacement Kit GM75376 Introduction
More informationGRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2
USER MANUAL MPI-1500/2000/3000/4000/6000 Series GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2 WWW.MPPSOLAR.COM WARNING: ONLY A CERTIFIED ELECTRICIAN OR TRAINED ASSEMBLING PROFESSIONAL SHOULD OPEN OR INSTALL
More informationIso DIN. User Manual. 1 channel Earth Fault Monitoring
Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee
More informationOPERATING INSTRUCTION
OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation
More informationUser's Guide. MiniTec TM Series Model MN25 MultiMeter
User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a
More informationMYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL
MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING
More informationAutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82175 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
More informationQuick Start Installation and User Manual
1 Quick Start Installation and User Manual Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation Settings
More informationProduct Specifications
Product Specifications Models: USC-10001, USC-10002 USC-20001, USC-20002 USC-30001, USC-30002 Guide Specification for UniStar C Series Rack/Universal 1, 2, 3Kva Single-Phase, On-Line Double Conversoin
More informationP4472 Save A Watt HD Operation Manual
P4472 Save A Watt HD Operation Manual Thank you for purchasing the P4472 Save A Watt HD. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation,
More informationMAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS
MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...
More informationAcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter
AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter Install Guide Revision C (12/18) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Revision C (12/18) Turn off all power supplying equipment
More informationTechnical Specificaions. kwh Energy Meter
Technical Specificaions of kwh Energy Meter (SPK301) Class 1.0S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email : info@spowerz.com
More informationSINUS PENTA 6. ACCESSORIES 6.1. BRAKING RESISTORS APPLICATION TABLES 111/209
INSTALLATION. ACCESSORIES.. BRAKING RESISTORS... APPLICATION TABLES From size S to size S, inverters are supplied with a built-in braking module. The braking resistor is to be connected outside the inverter
More informationUser Manual. Solar Inverter for Water Pump
User Manual Solar Inverter for Water Pump SP Revival Series Version: 1.2 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...
More informationUSER S GUIDE Programmable DC Power Supply Model IT6322
USER S GUIDE Programmable DC Power Supply Model IT6322 Copyright 2005 All Rights Reserved Ver1.0/Aug, 2005/ IT6300-508 CHAPTER 1 QUICK START... 6 1.1 Front Panel & Rear Panel...6 1.2 Preliminary Checkout...7
More informationATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)
Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product
More informationMYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL
MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR LC1 MANUAL 062114 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features Dimensions WIRING
More information2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...
TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...
More informationOZONE SWITCH Model OS-6. OS-6 Features
USER MANUAL OZONE SWITCH Model OS-6 OS-6 Features The OS-6 is an industrial grade ozone controller and monitor. The OS-6 design is optimized for accuracy and ease of installation, setup and operation.
More informationVLT 2800 DRIVE SPECIFICATIONS
VLT 2800 DRIVE SPECIFICATIONS Drive Input Power Input voltage 3 phase... 200 through 240, or 380 through 460; 3-phase all ratings 200 through 240, 1-phase through 2 HP Input voltage range for full output...
More informationDATA SHEET Compact Genset Controller, CGC 200
DATA SHEET Compact Genset Controller, CGC 200 Auto start and parameter monitoring Warnings and shutdown protections Includes 5 digital inputs, 5 relay outputs Configurable for other applications Licence-free
More informationInstallation Manual GENERAL DESCRIPTION...2 WIRING INFORMATION FOR NX-507 AND NX NX-507 TERMINAL DESCRIPTION...3 NX-507 DRAWING...
NX-0 RELAY EXPANDER NX-0 OUTPUT EXPANDER Installation Manual GENERAL DESCRIPTION... WIRING INFORMATION FOR NX-0 AND NX-0... NX-0 TERMINAL DESCRIPTION... NX-0 DRAWING... NX-0 TERMINAL DESCRIPTION... NX-0
More informationCDD4 Duct Carbon Dioxide Transmitter
Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean
More informationUPS READY POWER DISTRIBUTION ASSEMBLY
UPS READY POWER DISTRIBUTION ASSEMBLY FOR TRAFFIC CABINETS with LED Signals INSTALLATION & OPERATOR S MANUAL VERSION 1.2 1 Note The instructions contained in this manual are not intended to cover all of
More informationThis manual was downloaded on (0) TS8000. Firewire Option 8000/FA/00 HA Issue 1
TS8000 Firewire Option 8000/FA/00 HA471483 Issue 1 Copyright SSD Drives, Inc. 2006 All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted in any form
More informationAutoranging True RMS Multimeter User Manual
Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.
More informationML Multi Stage Thermostat Installation & User Guide
ML Thermostat PR0122-STA PR0123-STA ML Multi Stage Thermostat Installation & User Guide For Products: - PR0710, PR0711, PR0720, PR0721 Resource Data Management Ltd 80 Johnstone Avenue, Hillington Industrial
More informationOwner s Manual Revision 4.01 Option 1
Owner s Manual Revision 4.01 Option 1 Special Version of the SW series Inverter / Charger for Motor Coach Applications Part # 2031-7 (Supplement to Normal Manual) Effective Date: April 17, 1996 Trace Engineering
More informationMini Digital Multimeter
User's Guide Mini Digital Multimeter Model MN15 Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity
More informationJunos WebApp Secure 5.0 Hardware Guide
Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a
More informationTABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...
TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE... 2 1.0 General Information... 3 1.1 System Components... 3 1.2 Specifications... 3 1.2.1 Torque Ranges... 3 1.2.2 Electrical Specifications...
More informationUser s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389
User s Guide 600A True RMS AC/DC Clamp Meter Model 38389 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further
More informationEWCH 485 Electronic Pulse Counter
Electronic Pulse Counter Technical Data Sheet INSTRUMENT DESCRIPTION GENERAL DESCRIPTION is a programmable microprocessor based counter with 1or 2 outputs. The instrument offers the possibility to program:
More informationMiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities
MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs
More informationInstallation, Operation and Maintenance Manual
Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationTable of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A
Table of Contents 1. Important Safety Instructions... 2 2. Overview... 3 3. Product Functional Description... 4 3.1. Front Panel... 4 3.2. LCD Display Description... 5 3.3. Rear Panel... 6 3.4. Communication
More informationOperation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.
Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE4130 AUTOMATIC TRANSFER SWITCH CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND
More informationUser Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8
User Manual 2.2KW/7.5KW/11KW Solar Inverter for Water Pump Version: 1.8 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...
More informationModels beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)
Models beginning with 2M, 2L or 2X Series 2000 Multiple Meter Units (MMUs) Product Description Technical Specifications Installation Instructions February 28 th, 2013 List of Figures...2 List of Tables...2
More informationTechnical Specifications. Dual Source kwh Energy Meter
Technical Specifications of Dual Source kwh Energy Meter (SPKG300) Class 0.5S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Table of Contents 1. General Safety Requirements... 1 2. Safety Terms and Symbols...
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5320 AUTO MAINS FAILURE MODULE OPERATING MANUAL http://bestgenerator.spb.ru/?page_id=6765 Deep Sea Electronics Plc Highfield House Hunmanby North
More informationThermoelectric Cooler Controller TED1000
Thermoelectric Cooler Controller TED1000 Operating Instructions MANUAL-TED1000-1.0 Aug 2015 Rev.1 2 Contents 1 General... 4 1.1 Warranty and Assistance... 4 1.2 Maintenance... 4 1.3 General Safety Considerations...
More informationDEEP SEA ELECTRONICS PLC
DEEP SEA ELECTRONICS PLC 7xx series configuration software for Windows Software Manual Author Anthony Manton Deep Sea Electronics Plc Highfield House Hunmanby Industrial Estate North Yorkshire YO14 0PH
More informationDIN16A DIGITAL INPUT MODULE USER MANUAL
DIN16A DIGITAL INPUT MODULE USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou
More informationKodiak Mobile INTELLIGENT DOCKING STATION USERS MANUAL PART NUMBER: PANASONIC CF53 TOUGHBOOK COMPATIBLE AN ISO 9001:2008 CERTIFIED COMPANY
CUSTOMER SERVICE If you have any questions or require additional information please contact Customer Service at 877-455-6886, Monday though Friday, 8:00am - 5:00pm CST. TECHNICAL SUPPORT Kodiak Mobile
More informationQuick Start Guide TS 870 ATS
Quick Start Guide TS 870 ATS 100A - 800A (with TSC 900 Controller) DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating
More informationVBT-75 S2 VACUUM BOTTLE TESTER
VBT-75 S2 VACUUM BOTTLE TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 July 7, 2017 Revision 1 SAFETY
More informationATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)
Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component
More informationU-FLASH Setup Guide U-FLASH.
U-FLASH Setup Guide Thank you for purchasing the U-FLASH. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,
More informationBLDA-1 & 2 Water Leak Detection Manual. CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel:
BLDA-1 & 2 Water Leak Detection Manual CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel: 01825 733600 Contents 1) System Overview 2) Installation 3) Wiring 4) Water
More informationEPS Power Supply
EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------
More informationMP211 HARDWARE MANUAL
MP211 HARDWARE MANUAL MP211 PLC Series 10 / 2017 MIKRODEV_HM_MP211_EN V1.1 CONTENTS 1 MP211 GENERAL INFORMATION... 6 1.1 Physical Interfaces... 6 1.2 General Device Specifications... 7 2 INSTALLATION INFORMATION...
More informationH Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION
H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the
More informationPRO-1250D CT MID DIN rail three phase four wire energy meter.
PRO-1250D CT MID DIN rail three phase four wire energy meter. 1.1 Safety instructions 1.2 Foreword 1.3 MID certificate 1.4 Performance criteria 1.5 Specifications 1.6 Basic errors 1.7 Description 1.8 Dimensions
More informationInstallation and Operation Manual SPC1
Installation and Operation Manual SPC1 BIA-SPC1 rev 5 Page 1 TABLE OF CONTENTS Page QUICK GUIDE DRAINAGE PUMP FLOATS CONNECTED TO PANEL 4-5 QUICK GUIDE DRAINAGE PUMP FLOAT CONNECTED TO PUMP 6-7 QUICK GUIDE
More informationUSER MANUAL 2012 V1.1
SMART MINI POWER SDM630 USER MANUAL 2012 V1.1-1 - Installation and Operation Instructions Important Safety Information is contained in the Maintenance section. Familiarise yourself with this information
More informationUser's Guide. Extech AM A AC Analog Clamp Meter
User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.
More informationNetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup
NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL
More informationSIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018
SIRIUS CAPACITOR MODULE User Manual Model number: 3550-48-A-1.7C-M-SD-G Version 1.0; Release Date: April 2018 Introduction The Sirius Capacitor Module ( Sirius ) is supercapacitor-based storage that uses
More informationOPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES
PRICE: $25.00 LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES www.unipowertelecom.com Manual No. LVD-201-2 8/29/01/L46Man 2001 UNIPOWER Corp. All Rights Reserved UNIPOWER Telecom, Division of UNIPOWER
More informationQUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE
QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE User s Manual SR250HL Power Supply/ Float Charger for Lead Acid Batteries STANDARD FEATURES OPTIONAL FEATURES 3 Relay Alarms-Form
More informationMYRIAD RTU REMOTE TELEMETRY UNITS INSTRUCTION MANUAL
MYRIAD RTU REMOTE TELEMETRY UNITS INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR RTU MANUAL 061314 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING 8 Dwg
More informationEMS-GC10 Genset Controller. Modbus Communication Mapping Manual Section 75
EMS-GC10 Genset Controller Modbus Communication Mapping Manual 1311311 2013-10-10 Section 75 In order to consistently bring you the highest quality, full featured products, we reserve the right to change
More informationUser's Guide. Digital Multimeter. Model MN42
User's Guide Digital Multimeter Model MN42 Introduction Congratulations on your purchase of the Extech MN42 MultiMeter. The MN42 offers AC/DC Voltage, DC Current, and Resistance testing. Proper use and
More informationMini Digital Multimeter
User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series
More informationMaking Hazardous Operations Safe and Productive
NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series
More informationGenset Controller Unit Model EMS - GC10. Installation Manual Section
Genset Controller Unit Model EMS - GC10 Installation Manual 00-02-0794 Section 75 2013-01-28 In order to consistently bring you the highest quality, full featured products, we reserve the right to change
More informationCMSA-100 Manual. Cinema Media Server Automation
CMSA-100 Manual Cinema Media Server Automation 181 Bonetti Drive San Luis Obispo, CA 93401-7397 USA Phone: +1 805 549 0161 Fax: +1 805 549 0163 www.uslinc.com Table of Contents 1. Safety Notice... 3 2.
More informationUninterruptible Power Supplies
Xi Series 1-6kVA True On-Line UPS Features Rack-Mount/Standalone Format Universal Battery Design (Optional 10 year batteries) Dual Mains Input Dual Position Backlit LCD LCD Load Segment Control 2.5kVA
More information