1 TRANS-MAINS SYNCHRONISING & AUTOMATIC TRANSFER SWITCH. Introduction. General Specifications TRANS-MAINS is a mains control, synchronising and automatic transfer unit. The unit is designed to synchronise the gensets (controlled by TRAN-SYNCRO units) with mains supplies. The unit controls the change over from mains supply to genset supply or runs gensets in parallel with the mains to provide no-break, peak lopping and peak shaving power solutions. General Specifications: - Load sharing with genset (up to 32 gensets) - Busbar voltages and frequency measurements - Bus failure detection - Peak lopping (mains or genset) - Power export to mains - Mains de-coupling protection with R.O.C.O.F and vector shift methods - Volts, frequency and phase matching - Synchroscope display - functionality for PLC.2 Warranty EMKO Elektronik warrants that the equipment delivered is free from defects in material and workmanship. This warranty is provided for a period of two years. The warranty period starts from the delivery date. This warranty is in force if duty and responsibilities which are determined in warranty document and instruction manual performs by the customer completely..3 Maintenance Repairs should only be performed by trained and specialized personnel. Cut power to the device before accessing internal parts. Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene etc.). Use of these solvents can reduce the mechanical reliability of the device. Use a cloth dampened in ethyl alcohol or water to clean the external plastic case. Introduction Brochure. ENG TRANS-MAINS V5 4/8
2 Ýçindekiler 2. Installation! Before beginning installation of this product, please read the instruction manual and warnings below carefully. A visual inspection of this product for possible damage occured during shipment is recommended before installation. It is your responsibility to ensure that qualified mechanical and electrical technicians install this product. If there is danger of serious accident resulting from a failure or defect in this unit, power off the system and seperate the electrical connection of the device from the system. Keep the power off until all of the wiring is completed so that electric shock and trouble with the unit can be prevented. Ýçindekiler 2. Configuration The unit can be programmed using the buttons and LCD display on the front panel or PC Software. Ýçindekiler 2.2 Panel Mounting The unit is designed for panel mounting. Fixing is by two screw fixings. - Insert the unit in the panel cut-out from the front. 2- Insert the fixings in the slotted at the corners of the unit and tighten the fixing screws to secure the unit against the panel.! During the equipment is putted in hole on the metal panel while mechanical installation some metal burrs can cause injury on hands, you must be careful. LOG 88.6mm ESC PROG 62mm MAINS ON LOAD ON RESET AUTO TEST MAN mm Figure 2. Front View 223mm Figure 2.2 Panel Cut-Out 2
3 MAINS L L2 L3 N USB PROGRAMMING MAX. 3V~ MAINS CURRENT MAINS VOLTS L LOAD CURRENT M LOAD B GENERATOR BUS L L2 L3 N 64 SCR H(+) L(-) MULTI LINK COMMUNICATION (CAN OPEN) 2 Bus Contactor Output USB HOST ETHERNET 23 RJ BATTERY + - Connect the unit as shown in the appropriate diagram. Be sure to connect the battery supply the right way round 2- The first and last units must be fitted with a 2 ohm resisýtor across H and L. Screened cable must be used for connecting the communication, The screen is grounded at one end ONLY. 3- Current transformers secondary should be grounded. The CT of 5VA is recommended. BATTERY MAX. 3V~ BUS VOLTS TRANSISTOR OUTPUTS MAX. A TRANSISTOR OUTPUTS MAX. 5 A SCR A(+) B(-) RS485 COMMUNUCATION 2.3 Electrical Connection TRANS-MAINS three phase connections schematic Conf. Input-3 Conf. Input-2 FUSE- Conf. Input FUSE-2 Conf. Input- FUSE-3 Conf. Input-9 Conf. Input-8 Conf. Input-7 Mains Contactor Output Conf. Input-6 Conf. Input-5 8A Conf. Input-4 Bus closed aux. (Conf. Input-3) Mains closed aux. (Conf. Input-2) Emergency stop (Conf. Input-) Electrical interlock Mechanical interlock 8A Conf. Output-9 Conf. Output-8 Conf. Output-7 Conf. Output FUSE-4 Conf. Output-5 FUSE-5 Conf. Output-4 FUSE-6 Conf. Output-3 Conf. Output-2 Conf. Output- FUSE-8 BATTERY+ FUSE-7 TO OTHER UNITS ON THE BUS BATTERY - EARTH FUSE-, FUSE-2, FUSE-3, FUSE-4, FUSE-5, FUSE-6: 2 A. T FUSE-7: A. T FUSE-8: 32A. T 3
4 3. Changing And Saving Parameters Values Operation Screen BUSBAR V2: V V23: V V3: V V: V V2: V V3: V Fq:.Hz Phase seq.: PROGRAM Operator settings Technician settings Factory adjustment Wait for start When the Prog button is pressed, the parameters section is asked for accessing to parameters. Press the Up or Down buttons to select the section you wish to view/change. PROGRAM Operator settings Technician settings Press the Enter button. Password TECHNICIAN SETTING Factory adjustment Enter password with cursor (Right, Left, Up and Down) buttons. Password TECHNICIAN SETTING 62 TECHNICIAN SETTING.System 2.Mains 3.Generator 4.Engine 5.Inputs 6.Outputs 7.Timers 8.Expansion modules 9.Synchronization Note: If Enter button is pressed and the technician password is zero, Password screen is ignored. Press the Enter button to confirm password. If the password is incorrect, the unit will drop out of program mode. Press the Up or Down buttons to select the main parameter group you wish to view/change. TECHNICIAN SETTING.System 2.Mains 3.Generator 4.Engine 5.Inputs 6.Outputs 7.Timers 8.Expansion modules 9.Synchronization 2.MAINS.Volt level 2.Frequency level 3.Actions Press Enter button to access to all parameters page in currently main parameter group. Press Enter button to access to all parameters in currently parameter page. 4
5 3. Parametrelerin Ayarlanmasý 2..MAINS VOLT LEVEL.Under volt trip 2.Under volt return 3.Over volt trip 4.Over volt return 2..MAINS VOLT LEVEL.Under volt trip 32 Vac Press the Enter button to view parameter value. Parameter can be changed with Up and Down buttons. 2..MAINS VOLT LEVEL.Under volt trip 325 Vac 2..MAINS VOLT LEVEL.Under volt trip 2.Under volt return 3.Over volt trip 4.Over volt return Press Enter button to confirm the changed value. To exit from programming mode any time, press Prog button. 2.MAINS.Volt level 2.Frequency level 3.Actions When the Escape button is pressed any time, previous page can be accessed. BUSBAR V2: V V23: V V3: V V: V V2: V V3: V Fq:.Hz Phase seq.: Operation Screen Wait for start 5
6 4. Parameters 4. Operator Parameters 4.. Mains 2..MAINS VOLT LEVEL ( Mains-> Volt level).under volt trip Mains Under Voltage V 2. Under volt return Mains Under Voltage Return V 3.Over volt trip Mains Over Voltage V 4.Over volt return Mains Over Voltage Return V 2.2.MAINS FREQ. LEVEL ( Mains-> Frequency level) Mains Under Frequency Mains Under Frequency.Under freq trip 2. Under freq return 3.Over freq trip 4. Over freq return Return Mains Over Frequency Mains Over Frequency Return Hz Hz Hz Hz 4..2 Generator 3.6.GENERATOR GENERAL ( Generator->General) 3.All warning are latch All Warnings Are Latched En/Dis ENABL/DISBL DISBL Note: dis = disable 6
7 4.2 Technician Parameters 4.2. System..SYSTEM NETWORK ( System->Network).Mains CT ratio Mains Current Transformer Ratio 2. Load CT ratio Load Current Transformer Ratio 3.PT ratio Voltage Transformer Ratio 4.Type of AC system - Phase 2 Wire - 3 Phase 4 Wire 2-2 Phase 3 Wire L-L2 3-2 Phase 3 Wire L-L3 5.Phase sequence 6.Mains kw rating 7.Mains kvar rating. Nominal voltage. Nominal frequency System Phase Sequence Mains kw Rating Mains kvar Rating System Nominal Voltage System Nominal Frequency (dis) DISBL, L23, L (dis) 3 L kw kvar V Hz.2.BREAKERS ( System->Breakers).Type of Breaker 2.Busbar close breaker cont.type 3.Busbar close breaker relay typ 4.Busbar close timer 5.Busbar open breaker relay type 6.Busbar open timer 7.Mains close breaker cont.type 8.Mains close breaker relay type 9.Mains close timer.mains open breaker relay type.mains open timer 2.Breaker close pulse time 3.Breaker open pulse time 4.Transfer time 5.Spring loading time 6.Retry number Hardware Breaker Selection Bus Close Breaker Contact Type Bus Close Breaker Relay Type Bus Close Timer Bus Open Breaker Relay Type Bus Open Timer Mains Close Breaker Cont. Type Mains Close Breaker Relay Type Mains Close Timer Mains Open Breaker Relay Type Mains Open Timer Breaker Close Pulse Time Breaker Open Pulse Time Transfer Time Spring Loading Time Retry Number 3 NO / NC NO NOR / PULS 25 5 NOR / PULS 25 5 NO / NC NO NOR / PULS 25 5 NOR / PULS LCD DISPLAY ( System->LCD display).language Language Selection ENGLISH/TURKISH ENGLISH 2.Auto scroll time Auto Scroll Time (dis) 25 3.Auto scroll number 4.Err. mesg scroll time Auto Scroll Number Scroll Time For Error Messages SERIAL COMMUNICATION ( System->Serial Comm. ).Slave address Slave Address Baud rate Baud Rate: - 2 baud - 24 baud 2-48 baud 3-96 baud 4-92 baud baud Timeout Timeout (dis) Note- : NO / NC : Normally Open / Normally Close 2 : NOR / PULS : Normal / Pulse 7
8 .5.RS485 COMMUNICATION ( System->RS 485 Comm. ).Slave address Slave Address Baud rate Baud Rate: - 2 baud - 24 baud 2-48 baud 3-96 baud 4-92 baud baud ASCII/RTU selection ModBus ASCII/RTU Selection ASCII / RTU ASCII.6.DATA LOGGING ( System->Data logging).data log memory 2.Data log period Data Logging Memory.7.DATE & TIME SET ( System->Date & time set) Year Month.Year 2.Month 3.Day 4.Week 5.Hour 6.ute 7.ond -Disable -Internal memory 2-External USB Host Data log Period.(dis) Max 99 2 Date 3 Day of week 7 Hour 23 ute 59 ond 59 Default.8.DEFAULT SETTINGS ( System->Default settings).save setting to def. Save setting to default 2.Reset default sets Reset default sets 3.Reset factory sets Reset factory sets.9.password SETTINGS ( System->Password settings).operator password Operator Password 2.Technician password Technician Password YES / NO NO YES / NO NO YES / NO NO
9 4.2.2 Mains 2..MAINS VOLT LEVEL ( Mains-> Volt level).under volt trip Mains Under Voltage V 2. Under volt return Mains Under Voltage Return V 3.Over volt trip Mains Over Voltage V 4.Over volt return Mains Over Voltage Return V 2.2.MAINS FREQ. LEVEL ( Mains-> Frequency level) Mains Under Frequency Mains Under Frequency.Under freq trip 2. Under freq return 3.Over freq trip 4. Over freq return Return Mains Over Frequency Mains Over Frequency Return Hz Hz Hz Hz 2.3. MAINS ACTIONS ( Mains->Actions).Mains failure detection Mains Failure Detection En/Dis 2.Mains failure at stop mode Look Mains Failure at Stop Mode 3.Always return delay Always Look Mains Return Delay ENABL/DISBL ENABL ENABL/DISBL ENABL ENABL/DISBL DISBL Generator 3.5.GEN WORKING CALENDAR ( Generator->Working calendar).disable/enable select Calendar Disable or Enable 2.Start time on Monday Calendar Start Time on Monday 3.Stop time on monday Calendar Stop Time on Monday 4. Start time on tues. Calendar Start Time on Tuesday 5. Stop time on tuesday Calendar Stop Time on Tuesday 6. Start time on wednes. Calendar Start Time on Wednesday 7. Stop time on wednes. Calendar Stop Time on Wednesday 8. Start time on thurs. Calendar Start Time on Thursday 9. Stop time on thursday Calendar Stop Time on Thursday. Start time on friday Calendar Start Time on Friday. Stop time on friday Calendar Stop Time on Friday 2. Start time on satur. Calendar Start Time on Saturday 3. Stop time on saturday Calendar Stop Time on Saturday 4. Start time on sunday Calendar Start Time on Sunday 5. Stop time on sunday Calendar Stop Time on Sunday 3.6.GENERATOR GENERAL ( Generator->General) 3.All warning are latch All Warnings Are Latched En/Dis DISBL / ENABL DISBL H H H H H H H H H H H H H H. ENABL/DISBL DISBL Note: dis = disable 9
10 4.2.4 Engine 4.4.ENGINE PLANT BATTERY ( Engine->Plant battery).under volt Undervolts Warning 2. Under volt reset Undervolts Warning Reset 3. Under volt delay Undervolts Delay 4.Over volt Undervolts Warning 5. Over volt reset Overvolts Warning Reset 6. Over volt delay Overvolts Delay 6.(dis) (dis) V V V V 4.6.CANBUS ERROR SET ( Engine->CanBus error set).can fault actions Can Fault Actions: - Disable - Warning Non-Latching 2- Warning 3- Electrical Trip 4- Shutdown 2.CAN fault activation 3.CAN fault delay Can Fault Activation: - Active From Starting - Active From Safety On 2- Always Active Max (dis) 4 2 Default Can Fault Delay TEST MODE ( Engine->Test mode).disable/enable select Test Mode Selection DISBL / ENABL ENABL 4.9.EXERCISE ( Engine->Exercise).Disable/enable select Exercise Disable or Enable 2.Start time on monday Exercise Start Time on Monday 3.Stop time on monday Exercise Stop Time on Monday 4. Start time on tues. Exercise Start Time on Tuesday 5. Stop time on tuesday Exercise Stop Time on Tuesday 6. Start time on wednes. Exercise Start Time on Wednesday 7. Stop time on wednes. Exercise Stop Time on Wednesday 8. Start time on thurs. Exercise Start Time on Thursday 9. Stop time on thursday Exercise Stop Time on Thursday. Start time on friday Exercise Start Time on Friday. Stop time on friday Exercise Stop Time on Friday 2. Start time on satur. Exercise Start Time on Saturday 3. Stop time on saturday Exercise Stop Time on Saturday 4. Start time on sunday Exercise Start Time on Sunday 5. Stop time on sunday Exercise Stop Time on Sunday DISBL / ENABL DISBL H H H H H H H H H H H H H H. Note: dis = disable
11 4.2.5 Inputs 5.3.CONF. INPUT-X ( Inputs->Conf. input-x).dis,user conf.or list - Disable - User Configured 2- Select From List 2.Polarity - Normally Open (Close To Activate) - Normally Close (Open To Activate) 3.Indication 4.Activation 5.Select from list If User Configured - Status - Warning Non-Latching 2- Warning Latching 3- Electrical Trip 4- Shutdown If User Configured - Active From Starting - Active From Safety On 2- Always Active If Select From List -Remote Start On Load -Remote Start Off Load 2-Auxiliary Mains Fail 3-Bus Breaker Open/Close 4-Simulate Horn Reset Button 5-Simulate Alarm Reset Button 6-Simulate Auto Button 7-Simulate Test Button 8-Simulate Manual Button 9-Simulate Start Button -Simulate Stop Button -Bus Closed Auxiliary 2-Bus Load Inhibit 3-Mains Closed Auxiliary 4-Mains Load Inhibit 5-Auto Restore Inhibit 6-Auto Start Inhibit 7-Panel Lock 8-Scheduled Runs(Exercise) Inhibited 9-Top priority 2-Force Break Transfer 2-Force No-break Transfer 22-Force Soft Transfer 23-Force Parallel Operation 24-Mains Breaker Open/Close 25-Emergency Stop (for only input-) 26-Emergency Stop No-Latching (for only input-) (dis) 2 In,2,3=2 Others= In= Others= In=26 In=25 Others=24 In2=3 In3= Others=4 6.Active delay Input active delay 25 Note- : x = (input -), 2( input-2), 3( input-3), 4( input-4), 5( input-5), 6( input -6), 7(input -7), 8(input -8), 9(input -9), (input -), (input -), 2(input -2) or 3(input -3). Note-2 : dis = disable
12 5.6.CONF. EXP. INPUT-X ( Inputs->Conf. exp. input-x).dis,user conf.or list - Disable - User Configured 2- Select From List 2.Hardware type - > -Ve ( Switched To Battery -) - > +Ve ( Switched To Battery + ) 3.Polarity 4.Indication 5.Activation 6.Select from list 7.Active delay - Normally Open (Close To Activate) - Normally Close (Open To Activate) If User Configured - Status - Warning Non-Latching 2- Warning Latching 3- Electrical Trip 4- Shutdown If User Configured - Active From Starting - Active From Safety On 2- Always Active If Select From List 2-Auxiliary Mains Fail 3-Bus Breaker Open/Close 4-Simulate Horn Reset Button 5-Simulate Alarm Reset Button 6-Simulate Auto Button 7-Simulate Test Button 8-Simulate Manual Button 9-Simulate Start Button -Simulate Stop Button -Bus Closed Auxiliary 2-Bus Load Inhibit 3-Mains Closed Auxiliary 4-Mains Load Inhibit 5-Auto Restore Inhibit 6-Auto Start Inhibit 7-Panel Lock 8-Scheduled Runs(Exercise) Inhibited 9-Top priority 2-Force Break Transfer 2-Force No-break Transfer Input active delay (dis) 2 Max Default Note- : x = (exp. input -), 2( exp. input-2), 3( exp. input-3), 4( exp. input-4), 5( exp. Input-5), 6( exp. input -6), 7(exp. Input -7) or 8(exp. Input -8). Note-2 : dis = disable 2
13 4.2.6 Outputs 6..CONF. OUTPUT- ( Outputs->Conf. output-).polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) -NOT USED -RESERVED 2-ALARM RESET 3-AUDIBLE ALARM 4-AUTO START INHIBIT 5-AUXILIARY MAINS FAILURE 6-BATTERY HIGH VOLTAGE 7-BATTERY LOW VOLTAGE 8-CALLING FOR SCHEDULED RUN(EXERCISE) 9-RESERVED -RESERVED -RESERVED 2-COMMON ALARM 3-COMMON ELECTRICAL TRIP ALARM 4-COMMON SHUTDOWN ALARM 5-COMMON WARNING ALARM 6-RESERVED 7-RESERVED 8-RESERVED 9-RESERVED 2-RESERVED 2-RESERVED 22-DELAYED ALARMS ACTIVE 23-DIGITAL INPUT- ALARM 24-DIGITAL INPUT-2 ALARM 25-DIGITAL INPUT-3 ALARM 26-DIGITAL INPUT-4 ALARM 27-DIGITAL INPUT-5 ALARM 28-DIGITAL INPUT-6 ALARM 29-DIGITAL INPUT-7 ALARM 3-DIGITAL INPUT-8 ALARM 3-DIGITAL INPUT-9 ALARM 32-DIGITAL INPUT- ALARM 33-DIGITAL INPUT- ALARM 34-DIGITAL INPUT-2 ALARM 35-DIGITAL INPUT-3 ALARM 36-EXPANSION INPUT- ALARM 37-EXPANSION INPUT-2 ALARM 38-EXPANSION INPUT-3 ALARM 39-EXPANSION INPUT-4 ALARM 4-EXPANSION INPUT-5 ALARM 4-EXPANSION INPUT-6 ALARM 42-EXPANSION INPUT-7 ALARM 43-EXPANSION INPUT-8 ALARM 44-RESERVED 45-EMERGENCY STOP 46-RESERVED 47-RESERVED 48-RESERVED 49-RESERVED 5-RESERVED 5-GENERATORAT REST 52-GENERATOR AVAILABLE 53-BUS CLOSED AUXILIARY 54-BUS FAILED TO CLOSE 55-BUS FAILED TO OPEN 56-RESERVED 57-RESERVED 58-RESERVED 59-RESERVED 6-BUS LOAD INHIBIT 6-RESERVED 62-RESERVED 63-RESERVED 64-RESERVED 65-GENERATOR STOPPING 66-BUS OPEN BREAKER 67-HORN OUTPUT LATCHED 68-HORN OUTPUT PULSED 69-LAMP TEST 7-RESERVED 7-RESERVED 72-RESERVED 73-RESERVED 74-MAINS CLOSED AUXILIARY 75-MAINS FAILED TO CLOSE 76-MAINS FAILED TO OPEN 77-MAINS FAILURE 78-MAINS HIGH FREQUENCY 79-MAINS HIGH VOLTAGE 8-MAINS LOAD INHIBIT 8-MAINS LOW FREQUENCY 82-MAINS LOW VOLTAGE 83-MAINS OPEN BREAKER 84-NO LOADING COMMAND 85-RESERVED 86-RESERVED 87-RESERVED 88-RESERVED 89-RESERVED 9-RESERVED 9-RESERVED 92-RESERVED 93-RESERVED 94-RESERVED 95-PANEL LOCK 96-RESERVED 97-RESERVED 98-RESERVED 99-RESERVED -REMOTE START -RESERVED 2-RESERVED 3-RESERVED 4-RESERVED 5-STARTING ALARMS ARMED 6-RESERVED 7-SYSTEM IN AUTO MODE 8-SYSTEM IN MANUAL MODE 9-SYSTEM IN STOP MODE -SYSTEM IN TEST MODE -RESERVED 2-RESERVED 3-RESERVED 4-RESERVED 5-RESERVED 6-RESERVED 7-WAITING FOR GENERATOR 8-RESERVED 9-LOAD SUPPLY FROM BUS 2-LOAD SUPPLY FROM MAINS 2-RESERVED 22-RESERVED 23-RESERVED 24-RESERVED 25-RESERVED 26-RESERVED 27-RESERVED 28-REMOTE CONTROL ACTIVE 29-RESERVED 3-RESERVED 3-RESERVED 32-RESERVED 33-RESERVED 34-RESERVED 35-REMOTE OUTPUT 36-RESERVED 37-RESERVED 38-BUS NOT ALIVE 39-SYNCHRONIZATION FAIL 4-RESERVED 4-RESERVED 42-RESERVED 43-RESERVED 44-RESERVED 45-RESERVED 46-RESERVED 47-MAINS ROCOF ALARM 48-MAINS VECTOR SHIFT ALARM
14 6.2.CONF. OUTPUT-2 ( Outputs->Conf. output-2).polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options CONF. OUTPUT-3 ( Outputs->Conf. output-3).polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options CONF. OUTPUT-4 ( Outputs->Conf. output-4).polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options CONF. OUTPUT-5 ( Outputs->Conf. output-5).polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options CONF. OUTPUT-6 ( Outputs->Conf. output-6).polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options CONF. OUTPUT-7 ( Outputs->Conf. output-7).polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options CONF. OUTPUT-8 ( Outputs->Conf. output-8).polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options CONF. OUTPUT-9 ( Outputs->Conf. output-9).polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options CONF. EXP. OUTPUT- ( Outputs->Conf. exp. Output-).Polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options CONF. EXP. OUTPUT-2 ( Outputs->Conf. exp. output-2).polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options CONF. EXP. OUTPUT-3 ( Outputs->Conf. exp. Output-3).Polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options
15 6.4.CONF. EXP. OUTPUT-4 ( Outputs->Conf. exp. Output-4).Polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options CONF. EXP. OUTPUT-5 ( Outputs->Conf. exp. Output-5).Polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options CONF. EXP. OUTPUT-6 ( Outputs->Conf. exp. Output-6).Polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options CONF. EXP. OUTPUT-7 ( Outputs->Conf. exp. Output-7).Polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options CONF. EXP. OUTPUT-8 ( Outputs->Conf. exp. output-8).polarity 2.Function - Normally Open (Close To Activate) - Normally Close (Open To Activate) The same as Configurable Output- options Timers 7..START TIMERS ( Timers->Start timers).mains transient delay Mains Transient Delay Mains fail start delay Mains Fail Start Delay Remote start delay Remote Start Delay Horn duration Horn Duration (dis) STOPPING TIMERS ( Timers->Stopping timers).mains return delay Mains Return Delay 2.Remote stop delay Remote Stop Delay Note: dis = disable 5
16 4.2.8 Expansion Modules 8..IO (-8) MODULE ( Expansion modules->io (-8)).Disable/enable select Exp. I/O Module Selection Max ENABL/DISBL Default DISBL 8.2.DIAL-UP( Expansion modules->dial-up).disable/enable select Exp. Dial-up Module Selection 2.Call back selection Call Back Selection Max ENABL/DISBL ENABL/DISBL Default ENABL DISBL 8.4.GPRS MODULE ( Expansion modules->gprs).disable/enable select Expansion GPRS Module Selection 2.Call back selection 3.Cell info refresh rate 4.Location data 5.Location warning Call Back Selection Cell info refresh rate Location data Location warning -DISABLE -GPRS SERVER -GPRS SERVER 2-GPRS CLIENT 3-SMS ENABL/DISBL DISBL (dis) ENABL/DISBL DISBL (dis) 999 (dis) Km 8.5.GPRS WEB MODULE (Expansion modules->gprs Web).Disable/enable select GPRS-Web Module Selection Max ENABL/DISBL Default ENABL Note: dis = disable 6
17 4.2.9 Synchronization 9.3.PF CONTROL ( Synchronization->PF control) 6.PF control set Power Factor Control Set Value CANOPEN CONTROL ( Synchronization->CANOPEN control).device number 2.Baudrate 3.Message transmission rate 4.Data delay time 5.Can Open fault actions Device Number Baud Rate: Message Transmission Rate Data Delay Time Can Open fault actions kbaud ENABL/DISBL ENABL 9.6.SYNCHRON CONTROL ( Synchronization->Synchron control).deadbus voltage set 2.Maximum voltage difference 3.Positive frequency difference 4.Negative frequency difference 5.Maximum positive phase angle 6.Maximum negative phase angle 7.Relay closing time 8.Maximum synchronization time 9.Synchron dwell time.frequency set value offset Dead Busbar Voltage Level Maximum Voltage Difference Positive Frequency Difference Negative Frequency Difference Maximum Positive Phase Angle Maximum Negative Phase Angle Contactor Closing Time Maximum Synchronization Time Synchronization Dwell Time Slip Frequency Set Value Offset V 5 3 V.49. Hz. -.8 Hz msec Hz 9.9.SYNCHRON GENERAL (Synchronization->General 2.Number of gensets on system 3.imum genset fault actions Number Of Gensetss On System imum Genset Fault Actions: - Disable - Warning 2- Electrical Trip 3- Shutdown 32 2 (dis) 3 4.Number of mains on system Number Of Mains On System 32 5.Mains priority Mains Priority 32 7
18 9..BREAKER&LOAD CONT. ( Synchronization->Breaker&load cont).breaker transition mode Breaker Transition Mode Selection: - Break - No break 2- Soft 3- Parallel 2.No break transition time 3.Load control mode 4.Load control set 5.Load control hysteresis 6.Import power start delay 7.Import power stop delay 2.Soft transition high limit 3.Soft transition low limit 4.Soft transition timeout No break transition time Load Control Mode Selection: - Import Power - Export Power 2- Constant Power Load Control Set Load Control Hysteresis Import Power Start Delay Import Power Stop Delay Soft Transition High Limit Soft Transition Low Limit Soft Transition Timeout kw kw % % 9..MAINS DECOUPLING ( Synchronization->Mains decoupling).vector shift set Vector Shift Set Value 2.Rocof (df/dt) set Rocof (df/dt) Set Value 3.Rocof (df/dt) delay Rocof (df/dt) Delay 4.Mains decoupling actions Mains Decoupling Actions: - Warning - Electrical Trip 2- Auxiliary Mains Failure 5.Mains decoupling control delay Mains Decoupling Control Delay (dis).4(dis) º Hz/s
19 4.2...CONF. AUXILIARY FLAGS (Logic controller->conf. auxiliary flags).auxiliary flag-: Auxiliary Flag- Configuration 2.Auxiliary flag- 2: Auxiliary Flag-2 Configuration 3.Auxiliary flag- 3: Auxiliary Flag-3 Configuration 4.Auxiliary flag- 4: Auxiliary Flag-4 Configuration 5.Auxiliary flag- 5: Auxiliary Flag-5 Configuration 6.Auxiliary flag- 6: Auxiliary Flag-6 Configuration 7.Auxiliary flag- 7: Auxiliary Flag-7 Configuration 8.Auxiliary flag- 8: Auxiliary Flag-8 Configuration 9.Auxiliary flag- 9: Auxiliary Flag-9 Configuration.Auxiliary flag- : Auxiliary Flag- Configuration.Auxiliary flag- : Auxiliary Flag- Configuration 2.Auxiliary flag- 2: Auxiliary Flag-2 Configuration 3.Auxiliary flag- 3: Auxiliary Flag-3 Configuration 4.Auxiliary flag- 4: Auxiliary Flag-4 Configuration 5.Auxiliary flag- 5: Auxiliary Flag-5 Configuration 6.Auxiliary flag- 6: Auxiliary Flag-6 Configuration Max Default.2.CONFIGURE OUTPUTS (Logic controller->configure outputs).configurable output-: 2.Configurable output- 2: 3.Configurable output- 3: 4.Configurable output- 4: 5.Configurable output- 5: 6.Configurable output- 6: 7.Configurable output- 7: 8.Configurable output- 8: 9.Configurable output- 9: Configurable Output- Configuration Configurable Output-2 Configuration Configurable Output-3 Configuration Configurable Output-4 Configuration Configurable Output-5 Configuration Configurable Output-6 Configuration Configurable Output-7 Configuration Configurable Output-8 Configuration Configurable Output-9 Configuration Max Default.3.CONFIG. EXP. OUTPUTS (Logic controller->config. exp. outputs).config. expansion output-: 2.Config. expansion output- 2: 3.Config. expansion output- 3: 4.Config. expansion output- 4: 5.Config. expansion output- 5: 6.Config. expansion output- 6: 7.Config. expansion output- 7: 8.Config. expansion output- 8: Config. Exp. Output- Configuration Config. Exp. Output-2 Configuration Config. Exp. Output-3 Configuration Config. Exp. Output-4 Configuration Config. Exp. Output-5 Configuration Config. Exp. Output-6 Configuration Config. Exp. Output-7 Configuration Config. Exp. Output-8 Configuration Max Default.4.CONF. LOGIC FUNCTIONS (Logic controller->conf. logic functions) 4.Changed mode to auto: 5.Changed mode to test: 6.Changed mode to manual: 7.Changed mode to stop: 8.Informed mains interruption: Max Changed Mode To Auto Configuration Changed Mode To Test Configuration Changed Mode To Man Configuration Changed Mode To Stop Configuration Informed Mains Interrupt Configuration Default 9
20 .5.CONFIGURE TIMERS (Logic controller->configure timers).timer- hour Timer- Hour 2.Timer- minute Timer- ute 3.Timer- second Timer- ond 4.Timer-2 hour Timer-2 Hour 5.Timer-2 minute Timer-2 ute 6.Timer-2 second Timer-2 ond 7.Active day Active Day 8.Active hour Active Hour 9.Active minute Active ute.active second Active ond. Monday disable/enable Monday Disable/Enable 2. Tuesday disable/enable Tuesday Disable/Enable 3. Wednesday disable/enable Wednesday Disable/Enable 4. Thursday disable/enable Thursday Disable/Enable 5. Friday disable/enable Friday Disable/Enable 6. Saturday disable/enable Saturday Disable/Enable 7. Sunday disable/enable Sunday Disable/Enable Max ENABL/DISBL ENABL/DISBL ENABL/DISBL ENABL/DISBL ENABL/DISBL ENABL/DISBL ENABL/DISBL Default DISBL DISBL DISBL DISBL DISBL DISBL DISBL Hour Hour Hour.6. LOGIC CONTROLLER GENERAL (Logic controller-> General). Register set- 2. Register set-2 3. Register set-3 4. Register set-4 5. Register set-5 6. Register set-6 7. Register set-7 8. Register set-8 Register Set- Value Register Set-2 Value Register Set-3 Value Register Set-4 Value Register Set-5 Value Register Set-6 Value Register Set-7 Value Register Set-8 Value Max Default 4.2. User Adjustment.4. BATTERY VOLT OFFSET ( User adjustment->battery volt offset) MaxDefault.Batt.volt offset Battery Voltage Offset V 2
21 5. Specifications Equipment use : Electrical control equipment for generating sets. Housing & Mounting : 276 mm x 89 mm x 45 mm. (including connectors). Plastic housing for panel mounting. Panel Cut-Out : 223mm x 62mm. Protection : IP65 at front panel. Weight : Approximately,82 Kg. Environmental rating : Standard, indoor at an altitude of less then 2 meters with non-condensing humidity. Operating/Storage Temperature : -2 C to +7 C / -3 C to +8 C Operating/Storage Humidity : 9 % max. (non-condensing) Installation Over Volt. Category : II Appliances, portable equipment Pollution Degree : II, Normal office or workplace, non conductive pollution Mode of Operation : Continuous. DC Battery Supply Voltage : 8 to 32 V. Max. operating current is 86 ma. Cranking Dropouts : Battery voltage can be VDC for max. 5 ms during cranking (battery voltage should be at least nominal voltage before cranking). Battery Voltage Measurement : 8 to 32 V, Accuracy: % FS, Resolution:, V Busbar Voltage Measurement : 3 to 3 VAC Ph-N, 5 to 99.9 Hz. Accuracy: % FS, Resolution: V. Busbar Frequency : 5 to 99.9Hz (min. 2 VAC Ph-N) Accuracy:,25 % FS, Resolution:, Hz. Mains Voltage Measurement : 3 to 3 VAC Ph-N, 5 to 99.9 Hz. Accuracy: % FS, Resolution: V. Mains Frequency : 5 to 99.9Hz (min. 2 VAC Ph-N) Accuracy:,25 % FS, Resolution:, Hz. CT secondary : 5A. Communication interface : USB programming and communication port, CanOpen, Ethernet, RS485. Optional Expansion I/O Module : Expansion I/O module including 8 inputs and 8 outputs. Optional Comm. Modules : GSM/GPRS and Web Server modules. Relay Outputs : Bus contactor relay output 8A at DC supply voltage Mains contactor relay output 8A at DC supply voltage Transistor Outputs : Configurable output- 5A at DC supply voltage Configurable output-2 5A at DC supply voltage Configurable output-3,4,5,6,7,8,9 A at DC supply voltage Approvals :, 2
22 6. Other Informations Manufacturer Information: Emko Elektronik Sanayi ve Ticaret A.Þ. Demirtaþ Organize Sanayi Bölgesi Karanfil Sk. No: BURSA/TURKEY Phone : Fax : Repair and maintenance service information: Emko Elektronik Sanayi ve Ticaret A.Þ. Demirtaþ Organize Sanayi Bölgesi Karanfil Sk. No: BURSA/TURKEY Phone : Fax : Your Technology Partner Thank you very much for your preference to use Emko Elektronik Products. 22
TRANS-ATS AUTOMATIC TRANSFER SWITCH
TRANS-ATS AUTOMATIC TRANSFER SWITCH 1. Introduction 1.1 General Specifications The unit provides the mains voltage monitoring and automatic transfer switching. In the event of a mains voltage failure,
More informationTRANS-ATS AUTOMATIC TRANSFER SWITCH User Manual
TRANS-ATS AUTOMATIC TRANSFER SWITCH User Manual EMKO ELEKTRONÝK A. Þ. Demirta þ Org. San. Bolg. Karanfil Sk. No: 6 TR 16369 Bursa / TURKEY Phone Faks Url E-mail : +9 4 61 19 : +9 4 61 191 : www.emkoelektronik.com.tr
More informationTRANS-MINIAMF AUTOMATIC MAINS FAILURE UNIT
1.Introduction 1.1 General Specifications TRANS-MINIAMF MATIC MAINS FAILURE UNIT The unit provides for automatic transfer of a load from mains to generator in the event of a mains failure. Intended for
More informationTRANS-MINIAUTO AUTOMATIC START UNIT
TRANS-MINI MATIC START UNIT 1.Introduction 1.1 General Specifications The unit provides automatic start and stop the engine and protect the generator system. Both automatic and manual control is possible.
More informationESM-3711-CL 77 x 35 DIN Size, Minimum & Maximum Temperature Record, Digital, ON / OFF Cooling Controller
ESM-3711-CL 77x35 DIN Size Cooling Controller Internal Buzzer ESM-3711-CL 77 x 35 DIN Size, imum & imum Temperature Record, Digital, ON / OFF Cooling Controller - 3 Digits display - NTC input or, PTC input
More informationESM H 77x35 DIN Size Heating Controller Digital, ON / OFF Temperature Controller
Internal Buzzer ESM- 3711-H 77x35 DIN Size Heating Controller ESM-3711-H 77 x 35 DIN Size Digital, ON / OFF Temperature Controller - 3 Digits display - PTC Input or, J type Thermocouple Input or, K type
More informationINSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:
DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated
More informationHGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology
HGM9580 Bus Tie Bus Parallel Unit USER MANUAL Smartgen Technology This manual is suitable for HGM9580 bus tie bus parallel unit only. Clarification of notation used within this publication. SIGN INSTRUCTION
More informationEPM x35 DIN Size Control Panel For V/F Speed Controller
EM-3790 77x35 DIN Size Control anel For V/F Speed Controller EM-3790 77 x 35 DIN Size Control anel For V/F Speed Controller - 4 Digits Display - Easily adjustable set value from front panel - Configurable
More informationATS CONTROLLER OPERATING MANUAL
HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER OPERATING MANUAL Smartgen Electronic CONTENT 1 SUMMARY... 4 2 PERFORMANCE AND CHARACTERISTICS... 4 3 SPECIFICATION... 5 4 OPERATING... 6 4.1
More informationTRANS-SYNCRO SYNCHRONISING & LOAD SHARING UNIT FOR GAS/DIESEL/GASOLINE GENERATORS WITH J1939 ECUs User Manual
TRANS-SYNCRO SYNCHRONISING LOAD SHARING UNIT FOR GAS/DIESEL/GASOLINE GENERATORS WITH J1939 ECUs User Manual EMKO ELEKTRONÝK A.Þ. Demirtaþ Org. San. Bolg. Karanfil Sk. No: 6 TR 16369 Bursa / TURKEY Phone
More informationHAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL
HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD CONTENT 1 OVERVIEW... 5 2 PERFORMANCE AND CHARACTERISTICS... 6 3 SPECIFICATION... 8 4 OPERATING...
More informationMULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:
MULTI-LINE 2 APPLICATION NOTES Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com
More informationEMS-GC10 Genset Controller. Modbus Communication Mapping Manual Section 75
EMS-GC10 Genset Controller Modbus Communication Mapping Manual 1311311 2013-10-10 Section 75 In order to consistently bring you the highest quality, full featured products, we reserve the right to change
More informationDEEP SEA ELECTRONICS PLC DSE334 Configuration Suite Software Manual
DEEP SEA ELECTRONICS PLC DSE334 Configuration Suite Software Manual Document Number 057-156 Author: Paul Gibbons DSE334 Configuration Suite Software Manual ISSUE 1 DSE334 Configuration Suite Software Manual
More informationHAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL
HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co.,
More informationACCESS 9340/9360 Meter Input/Output Module
Installation Manual PMIM-IOMOD-0208 ACCESS 9340/9360 Meter Input/Output Module 9340-60-I/O2222 and 9340-60-I/O26 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the
More informationDM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER
DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is
More informationTechnical Specificaions. kwh Energy Meter
Technical Specificaions of kwh Energy Meter (SPK301) Class 1.0S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email : info@spowerz.com
More informationGenset Controller Unit Model EMS - GC10. Installation Manual Section
Genset Controller Unit Model EMS - GC10 Installation Manual 00-02-0794 Section 75 2013-01-28 In order to consistently bring you the highest quality, full featured products, we reserve the right to change
More informationProduct Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx
ECO Types ECG, AMF Technical data Product overview ECO ECG and ECO AMF are microprocessor controlled devices for use in low voltage single genset applications for standby power generation. The front-side
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5520 AUTOMATIC MAINS FAILURE CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND
More informationQuick Start Guide TS A
Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer
More informationIso DIN. User Manual. 1 channel Earth Fault Monitoring
Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee
More informationDKM-407 DIN RAIL TYPE NETWORK ANALYZER
DKM-407 User Manual DKM-407 DIN RAIL TYPE NETWORK ANALYZER DESCRIPTION The DKM-407 is a DIN rail mounted precision and low cost unit allowing measurement and remote monitoring of AC parameters of a distribution
More informationMIC-2 MKII, Multi-instrument DATA SHEET
MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationMultifunction Transducer MT440
Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up
More informationSOLARIMMERSION IV Advanced Installation Manual v1.9
SOLARIMMERSION IV Advanced Installation Manual v1.9 1 Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation
More informationMIC-2 Multi-instrument DATA SHEET
Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules
More informationPFC-10 Power Factor Controller
PFC-10 Power Factor Controller Instruction Manual Ver. 6.0 / 2002 (2-2005 update) Table of Contents Page Subject 3 Starter ion 4-5 Installation Notes 6-7 Terminals Review & Control Wiring 8 Front-panel
More informationTT /12b INSTALLATION INSTRUCTIONS. Introduction
TT-1545 11/12b INSTALLATION INSTRUCTIONS Original Issue Date: 6/10 Model: 20-300 kw Generator Sets Market: Industrial Subject: Decision-Maker 3000 Controller Service Replacement Kit GM75376 Introduction
More information100% electricity. Automatic transfer switch controllers ATL series
100% electricity Automatic transfer switch controllers ATL series Automatic transfer switch controllers Keep control around the clock General characteristics Rated auxiliary power supply: 220-230-240VAC
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More informationPowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006
PowerLogic power-monitoring units Technical data sheet 2006 Functions and characteristics E90463 The PowerLogic PM500 Power Meter provides all measurement capabilities required to monitor an electrical
More information2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...
TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...
More informationComprehensive Modular Genset Controller
Inteligen Learn More Comprehensive Modular Genset Controller Brief Description The Inteligen is a comprehensive controller for single and multiple generating sets operating in standby or parallel to the
More informationTIME SERVER NETSILON. Quick start.
TIME SERVER NETSILON Quick start This document refers to the following products: 907,900 NETSILON 7 (100-240 VAC) 907,901 NETSILON 7 (18-36 VDC) 907,902 NETSILON 7 (100-240 VAC + 18-36 VDC) www.bodet-time.com
More informationTechnical Specifications. Dual Source kwh Energy Meter
Technical Specifications of Dual Source kwh Energy Meter (SPKG300) Class 0.5S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email
More informationATS Automatic transfer switches Advanced version
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 ATS CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 5. CONFORMITY 4 6. EQUIPMENTS
More informationQUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE
QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE User s Manual SR250HL Power Supply/ Float Charger for Lead Acid Batteries STANDARD FEATURES OPTIONAL FEATURES 3 Relay Alarms-Form
More informationML Multi Stage Thermostat Installation & User Guide
ML Thermostat PR0122-STA PR0123-STA ML Multi Stage Thermostat Installation & User Guide For Products: - PR0710, PR0711, PR0720, PR0721 Resource Data Management Ltd 80 Johnstone Avenue, Hillington Industrial
More informationGenset control and protection with safety system
APPLICATION NOTES Generator Protection Unit, GPU-3 APPLICATION NOTES Genset control and protection with safety system Application description Functional description Wiring I/O lists Basic setup Flowcharts
More informationManual TU510A. Auto Transfer Controller HM1043ER1
Harsen Manual TU510A Auto Transfer Controller HM1043ER1 History History No. Rev. Date Editor Validation Changes 1 HM1043ER1 2011.1.1 P.L New Harsen I Contents Contents Description... 1 1. The Outline Dimensional
More informationESM x 96 1/4 DIN Temperature Controller with Universal Input
ESM-9920 96x96 1/4 DIN Temperature Controller ESM-9920 96 x 96 1/4 DIN Temperature Controller with Universal Input - 4 digits process(v) and 4 digits process set value(sv) display - Universal process input
More informationTechnical Specifications. Multi Function Meter
Technical Specifications of Multi Function Meter (SPM300) Class 0.5S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email : info@spowerz.com
More informationDIN16A DIGITAL INPUT MODULE USER MANUAL
DIN16A DIGITAL INPUT MODULE USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou
More informationInstallation Manual. Multi Power Controller MPC-1 multi-line D
Installation Manual Multi Power Controller MPC-1 multi-line Complete control system in one package: - island operation - parallel with mains operation - emergency generator control 3-phase AC measurements
More informationAGC 200 Advanced Gen-set Controller DATA SHEET
AGC 200 Advanced Gen-set Controller DATA SHEET Operation modes Automatic mains failure Island operation Fixed power/base load Peak shaving Load take over Mains power export Protection (ANSI) 5 x Overload
More informationModel P4470 Save A Watt Operation Manual
Model P4470 Save A Watt Operation Manual Thank you for purchasing the P4470 Save A Watt. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation,
More informationMultiple Generator Automatic Synchronising System
R Millennium Power Manufacturing Corp. R Multiple Generator Automatic Synchronising System Synchronising System Type Choice Independent Control Cabinet Type Feature: Independent Control Cabinet Type Functions:
More informationEC700. Pulses concentrator. User instructions
EC700 Pulses concentrator User instructions Contents Hazards and warning... 3 Initial checks... 3 Introduction... 4 Jbus/Modbus Communication... 5 Installation... 6 Configuration... 9 Use... 9 Programming...
More informationPRO1250D CT MODBUS MID Three phase four wire energy meter.
PRO1250D CT MODBUS MID Three phase four wire energy meter. User manual Version 1.11 1 Safety instructions...3 2 Foreword...4 3 MID certificate...5 4 CE certificate...6 5 Performance criteria...8 6 Specifications...8
More informationMULTI-LINE 2 APPLICATION NOTES
MULTI-LINE 2 APPLICATION NOTES Converting PPM-2 to PPM 300 Parameter conversion Wiring Options I/O list Modbus DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com
More informationMIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET
& DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationINSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers
2010-12-10 5011699201-PBB1 Eaton Logic Controller ELCB Controllers INSTRUCTION SHEET [Applicable Controllers] ELCB-PB10 ELCB-PB14 ELCB-PB20 ELCB-PB30 ELCB-PB40 IL05001005E 002-1310020-02 Thank you for
More informationQuick Start Installation and User Manual
1 Quick Start Installation and User Manual Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation Settings
More informationGRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2
USER MANUAL MPI-1500/2000/3000/4000/6000 Series GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2 WWW.MPPSOLAR.COM WARNING: ONLY A CERTIFIED ELECTRICIAN OR TRAINED ASSEMBLING PROFESSIONAL SHOULD OPEN OR INSTALL
More informationCEM M-RS485 INSTRUCTION MANUAL (M014B A)
Communications interface CEM M-RS485 INSTRUCTION MANUAL (M014B01-03-14A) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below. DANGER Warns of a risk, which could
More informationUser's Guide. MiniTec TM Series Model MN25 MultiMeter
User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a
More informationMID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID
PRELIMINARY DATA SHEET RI-D35-100 Series Single Phase Multifunction Energy Meter (MID Certified) MID direct connected Two pulse outputs LED pulse indication High definition LCD display with white backlight
More informationEZM x72 DIN SIZE Programmable Counter. EZM x 72 DIN Size Universal Input Programmable Counter
EZM-7730 72x72 DIN SIZE rogrammable Counter EZM-7730 72 x 72 DIN Size Universal Input rogrammable Counter - 6 digits rocess (V) and 6 digits Set (SV) Value Display - Operation with 1 Set Value - Reset,
More informationTechnical Specifications. Dual Source Energy Meter (EB / DG)
Technical Specifications of Dual Source Energy Meter (EB / DG) (SPMG300) Class 0.5S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com
More informationAcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter
AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter Install Guide Revision C (12/18) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Revision C (12/18) Turn off all power supplying equipment
More informationInterface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016
Interface Definition RISH EM 2340/1320/30/40 1 2-60-006-00-00494_Rev. D - 8/2016 2 Section DIGITAL MULTIFUNCTION INSTRUMENT Contents 1. Introduction Programmable Multi-function Energy Meter Installation
More informationTable of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A
Table of Contents 1. Important Safety Instructions... 2 2. Overview... 3 3. Product Functional Description... 4 3.1. Front Panel... 4 3.2. LCD Display Description... 5 3.3. Rear Panel... 6 3.4. Communication
More informationProducts no longer available
Technical data sheet BKS24-.. MONICO-Controller BKS24-.. Forms an efficient fire protection system together with the motorisation sets BF(G)24MP Controller with application software for control and monitoring
More informationQuantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III
Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North
More informationOwner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español
Owner's Manual True RMS Multimeter Model No. 82023 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español
More informationManual 09/11 MN Z-EN. NZM-XATS-C Automatic Transfer Switch-Controller Modbus Communication Protocol
Manual 09/11 MN01219007Z-EN NZM-XATS-C Automatic Transfer Switch-Controller Modbus Communication Protocol All brand and product names are trademarks or registered trademarks of the owner concerned. Emergency
More informationVoltage Transducer UMT516 / MT516
Voltage Transducer UMT516 / MT516 True RMS AC voltage measurements Voltage auto range measurements up to 600V # Wide frequency measurement range 16 400 Hz High accuracy class 0.2 (IEC-688), 0.1 on communication
More informationATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink
Characteristics variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application
More informationAPU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET
APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET Measurement input, auto range Up to 1000 V AC L-L Up to 12.5 A (sinusoidal) 16 400 Hz Output Up to four analogue outputs Relay output RS 485 Modbus
More informationUser Manual. Solar Inverter for Water Pump
User Manual Solar Inverter for Water Pump SP Revival Series Version: 1.2 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...
More informationDATA SHEET Compact Genset Controller, CGC 200
DATA SHEET Compact Genset Controller, CGC 200 Auto start and parameter monitoring Warnings and shutdown protections Includes 5 digital inputs, 5 relay outputs Configurable for other applications Licence-free
More informationOPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR
1 OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR Micro Seven, Inc. 1095-K N.E. 25 th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982 fax: 503-693-9742, email to: sales@microseveninc.com www.microseveninc.com
More informationPRO1250D CT M-bus MID DIN rail three phase four wire energy meter. User manual Version 1.11
PRO1250D CT M-bus MID DIN rail three phase four wire energy meter. User manual Version 1.11 1 Safety instructions...3 2 Foreword...4 3 MID certificate...5 4 CE certificates...6 6 Performance criteria...8
More informationApplication Note (Revision NEW) Original Instructions. EGCP-2 Differences
Application Note 51199 (Revision NEW) Original Instructions General Precautions Read this entire manual and all other publications pertaining to the work to be performed before installing, operating, or
More informationQUICK START GUIDE Paralleling and Protection Unit PPU 300
QUICK START GUIDE Paralleling and Protection Unit PPU 300 DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4189341107B 1. Introduction
More informationTRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features
TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation
More informationATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet
Characteristics variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet Main Range of product Product or component type Device application Device short name Variant Product destination Mounting
More informationP4472 Save A Watt HD Operation Manual
P4472 Save A Watt HD Operation Manual Thank you for purchasing the P4472 Save A Watt HD. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation,
More informationWhat is new in the easygen3000xt
PRELIMINARY What is new in the easygen3000xt Content Hardware... 3 Housing... 3 New Layout / Operation... 3 Base Models... 3 Terminals... 4 I/O Features... 4 Communication Interfaces... 4 Functionality...
More informationOption H3 Serial communication Profibus DP
MULTI-LINE 2 DESCRIPTION OF OPTIONS Option H3 Serial communication Profibus DP Description of option Functional description Parameters Data tables Document no.: 4189340443H Multi-line 2 Option H3, Serial
More informationUser s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389
User s Guide 600A True RMS AC/DC Clamp Meter Model 38389 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further
More informationR5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com
Model R5050 TRMS AC/DC Clamp Meter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-6 Instrument Description...7-8 Measurement Procedures...9-12 Battery
More informationInteliPro. Protection Relay for Parallel Applications. Technical Specification
InteliPro Protection Relay for Parallel Applications Product description InteliPro is a highly flexible interconnection/mains decoupling protective relay with extensive protective functions. It meets the
More informationM260 Load Cell Amplifiers
E L 4 - + 2-3 1-2 M260 Load Cell Amplifiers Description. This fast start guide shows basic installation, setup, and calibration for most applications. For more specific information contact Minsterport.
More informationRGM180 Display Series
Quick Start Guide RGM180 Display Series BG0509 REV.A2 RGM180 QUICKSTART LIMITED WARRANTY The manufacturer offers the customer a 24-month functional warranty on the instrument for faulty workmanship or
More informationCompact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus
DATA SHEET Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus DEIF A/S Frisenborgvej 33 DK-7800 Skive
More informationMYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL
MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING
More informationInstallation Manual GENERAL DESCRIPTION...2 WIRING INFORMATION FOR NX-507 AND NX NX-507 TERMINAL DESCRIPTION...3 NX-507 DRAWING...
NX-0 RELAY EXPANDER NX-0 OUTPUT EXPANDER Installation Manual GENERAL DESCRIPTION... WIRING INFORMATION FOR NX-0 AND NX-0... NX-0 TERMINAL DESCRIPTION... NX-0 DRAWING... NX-0 TERMINAL DESCRIPTION... NX-0
More informationTemperature/Process Controllers Manual
3200 SERIES Temperature/Process Controllers Manual The innovative range of 3200 controllers offer precision control of temperature and other process variables together with a host of advanced features
More informationATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21
Characteristics variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination
More informationPRO2DM DIN rail single phase two wire energy meter
PRO2DM DIN rail single phase two wire energy meter User manual Version 1.04 1 Safety instructions...3 2 Foreword...4 3 CE Certificate...5 4 Performance criteria...6 5 Specifications...6 6 Basic errors...6
More informationDGC-2000 DIGITAL GENSET CONTROLLER
DGC-2000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-2000) offers an integrated alternative for genset control and monitoring. Control includes engine starting and shutdown
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE705 ATS CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723
More informationUSER MANUAL 2012 V1.1
SMART MINI POWER SDM630 USER MANUAL 2012 V1.1-1 - Installation and Operation Instructions Important Safety Information is contained in the Maintenance section. Familiarise yourself with this information
More informationINSTALLATION MANUAL Z-UMTS
INSTALLATION MANUAL Datalogger HSPA + with built-in I/O, telecontrol functions, embedded UPS and advanced programming language EN SENECA s.r.l. Headquarters: Via Austria, 26 35127 PADOVA ITALY Phone +39.049.8705355-8705359
More informationDKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY
datakom@datakom.com.tr http://www.datakom.com.tr Tel: +9-216 466 84 6 Fax: +9-216 364 65 65 DKM-45 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY INTRODUCTION The DKM-45 is a low cost precision
More informationFunction permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%
Operating range: 0.10 to 30 xin (step 0.01) 50P(2) Activation level 100% Deactivation level 95% Timer accuracy: 30 ms Operating range: 0.10 to 30 xin (step 0.01) 50N/G(2) Activation level 100% Deactivation
More information