Details on reader configuration, administration and general functionality are contained in the Cheetah SE Reader User Guide.

Size: px
Start display at page:

Download "Details on reader configuration, administration and general functionality are contained in the Cheetah SE Reader User Guide."

Transcription

1 Innometriks Cheetah SE Reader Quick Start Guide REVISION B0 APRIL 2018 Overview This guide provides quick start installation and connection information for the Cheetah SE Reader models. The reader is configured using the web browser. See Browser Based Administration on Page 12. Default or configured settings can be displayed using the keypad. See Keypad Operation on Page 11. NOTE Details on reader configuration, administration and general functionality are contained in the Cheetah SE Reader User Guide. Figure 1: Contactless and Contactless/Contact Cheetah SE Reader Models Figure 1 on Page 1 shows the indoor contactless and contactless/contact models of the readers. In addition, there are outdoor models with the same dimensions as their indoor counterparts. Over the keypad of every reader are four function keys, F1 to F4, from left to right. Ordering Codes Table 1: Cheetah SE Reader Product Codes Product Codes INN-SECHTA-RF INN-SECHTA-CT INN-SECHTA-RFO INN-SECHTA-CTO Description Indoor: RF Only (Contactless) Indoor: RF and Contact Outdoor: RF Only (Contactless) Outdoor: RF and Contact

2 Features The Innometriks Cheetah SE Reader is a networked smart card reader that provides: Compact design Smart card authentication - contactless or contact reader models HID SE module contactless Smart Reader Carrier frequency of the RF interface: MHz. Supported card formats: iclass, PIV, PIV-I, CAC, TWIC, MIFARE, DESFire, EV1, EV2, smart card CSN, HID SEOS. Microchip SEC1210 Smart Card Reader (contact) & HID SE module (contactless) The HID module supports all features above. Standard smart cards are supported: CAC, PIV, PIV-I, TWIC. A slot at the bottom of the reader accepts insertion of these chip cards. NOTE MIFARE proximity cards are Underwriters Laboratories (UL) tested for contactless authentication. 200 bit PIV and 128 bit PIV-I are UL tested for contact and contactless authentication. Controller communications Gigabit Ethernet communication, used for configuration and troubleshooting Supports both RM and OSDP protocols RM communication to the istar Ultra or istar Ultra SE panel. OSDP communication is supported from the reader through an RS485 connector then to any PACS (physical access control system) which supports OSDP. NOTE Innometriks services communicate with readers across TCP/IP using ports 5001 and In environments with multiple network segments, all intermediate routers and switches must be set to forward TCP ports 5001 and Ethernet is not UL tested. Connect Ethernet only when configuring or troubleshooting the reader. OSDP is not verified by UL. LCD display - 2x16 characters; adjustable brightness set via keypad Keypad - 3x4 touchpad for adjusting LCD display brightness and displaying reader parameters Contains numerals 0-9 and four unmarked function keys F1 to F4, over the numerals Buzzer - Indicates card read has occurred Inputs/Outputs Two supervised inputs Two physical outputs: one dry contact relay, one optically isolated TTL output One virtual output NOTE The optically isolated TTL output also serves as the Normal/Secure switch for some reader profiles. This output indicates the state of the Normal/Secure reader operational mode. Evaluated by UL as a configurable output. The virtual output is used in FICAM to set Secure Mode operation. Both the TTL output and the Virtual output operate as Output Two in RM and will trigger together. Tamper support - enabled in PACS software Three indicator LED light bars LED light bars at the left and right sides of reader show Access Granted, Access Denied or Enter PIN. The LED light bar at the bottom of the contact reader shows reader readiness for inserting a chip card. 2

3 Web browser support and firmware/configuration file manipulations Includes support for updating reader firmware through a web browser. Provides for saving or uploading the reader configuration to/from a file. PACS / Reader formations - single reader, star, daisy chain NOTE The configuration file contains all independent reader settings such as Normal and Secure mode settings, card support configuration, and reader communication options (RM, OSDP). Web browser, firmare updates, and configuration are not UL evaluated. Only the single reader configuration is UL tested. Standards NOTE Cheetah SE readers are UL listed to Standard UL294, Access Control Systems. UL has not evaluated Ethernet or FICAM. Ethernet is not for permanent connection. Do not mount outside of the protected area when access point actuator is controlled by unit's relay outputs. Specifications Network and I/O Cables Table 2: Network and I/O Cables Usage Cable Description Network Cat5 Ethernet - reader to host system. Ethernet connections are used only for configuration and troubleshooting. Do not permanently connect Ethernet. Use standard Ethernet cables and adhere to standard Ethernet distances. Maximum length of this cable is 300 ft (100 m). Data - PACS to reader Recommended Belden #9841 or equivalent The maximum length is 4000 ft (1219 m) between the PACS and the reader. Data - RS485 to reader Twisted pair minimum of 22 AWG For RS485 communications to a reader. You can also use a stranded cable. In either case, you should use a shielded cable when readers communicate in noisy environments. Maximum RS485 wire length is 4000 ft (1219 m). Input The maximum length is 500 ft (152 m) Optical relay The maximum length is 500 ft (152 m) 3

4 Power Source Requirements The Cheetah SE Reader requires nominally 12 VDC at 1 Amp to operate correctly. The power source can be from the power supply on the PACS or can be a separate local supply. The reader must be powered by a compatible UL listed access control panel or a UL294 listed power supply. CAUTION: If you are using a separate local power supply, ensure that the ground of the local supply connects to the ground of the PACS. The local power supply must be a UL listed access control power source. UL 1076 burglar installations require UL 603 listed power supply with minimum 4 hours standby power. Power Wiring The wiring to deliver power to the reader should conform to proper electrical installation practices and codes, and should be of a gauge required to deliver the required voltage and current to the reader without excessive loss or heating. Wiring methods shall be in accordance with the National Electrical Code ANSI/NFPA 70 or CSAC Canadian Electrical Code, Part 1, Safety Standard for Electrical Installations. The recommended power wiring is Belden #8461/8442 twisted pair. The maximum length depends on the wire gauge. Installation This section contains the instructions for wiring the readers and mounting the reader on a wall or similar support. Reader Dimensions Figure 2 on Page 4 shows the physical dimensions of the Cheetah SE readers. The dimensions of the contactless reader are the same as the contact models, except that the contact models have a card insertion slot at the bottom and the contactless models have no slot and have eliminated the recess for that slot. Figure 2: Reader Dimensions Pre-Installation Checks Site Check power, wiring, equipment clearances, and code compliance at the site. Ensure that the mounting site is ready by verifying that: the site has been approved and all wiring complies with UL requirements and other codes, as appropriate. all preliminary site work is complete, and the site is clean and free of dust or other contaminants. an appropriate power supply is accessible. the reader operating temperature is 14 F (-10 C) to F (66 C). When installing the reader, use anchoring systems capable of sustaining a load of at least 25 lb. 4

5 Tools Ensure the proper tools (not supplied) are available: small needle nose pliers, small Phillips screwdriver, small Torx screwdriver, wire strippers. Mounting Plate Figure 3 on Page 5 shows front and back views of the mounting plate for the Cheetah SE readers. Figure 3: Mounting Plate Front and Back Views Installation Instructions To remove the mounting plate from the reader housing: 1. The mounting plate is delivered connected to the reader housing by two Torx screws located at the bottom of the reader housing, as shown in Figure 3 on Page 5. Using a Torx screwdriver, remove the two Torx screws from the bottom of the housing. 2. Separate the mounting plate from the reader housing. 3. Remove the 6-pin and 9-pin Molex connectors from the reader housing if already connected. To wire the connectors: Disconnect all power sources before modifying the wiring. 1. Wiring should use proper ESD procedures and follow instructions shown in Wiring Diagrams on Page Reconnect the Molex connectors to the reader housing. 5

6 To attach gaskets to mounting plate (outdoor installations only): Figure 4: Mounting Plate with Outdoor Gaskets 1. Insert the perimeter gasket to the front of the mounting plate and attach the wall gasket to the rear of the mounting plate (both gaskets supplied loose in the Outdoor Install Kit). See Figure 4 on Page 6. To secure the mounting plate to a support: Figure 2 on Page 4 shows the dimensions of the mounting plate (matches the back plate of the reader). With the mounting plate facing forward, attach the mounting plate to a wall or other support by inserting two or four screws (not supplied) into the mounting plate holes (see Figure 5 on Page 6). The type of screws depends on the type of support used. Figure 5: Mounting Reader to a Support For mounting outdoors, the wall plate will most likely be attached to a brick wall. Suitable screws and wall anchors (not supplied) would be: No. 6 (3.5mm) x 1" long minimum PHIL CSK Tapping Screw A2 Stainless Steel: Figure 6: Screws for attaching reader to brick wall Gauge/Metric: #6 (3.5) dk: ; k (max): 2.10; d (drive): #2 For mounting indoors, wall anchors (not supplied) that can be used include: ANCH PL W/O SCR 7/8L #6 #8 # Butterfly Wall Plug for #6 Screw (for hollow/dry wall) 6

7 Figure 7: Attaching Reader to Mounting Plate To attach the reader housing to the mounting plate: 2. Affix the reader housing to the secured mounting plate. 3. Secure the reader housing to the mounting plate using proper ESD procedures by inserting screws (supplied) into the two seats at the bottom of the reader. The type of screws should be Screw 4-40 UNC x 1/2" CSK Socket 4. Apply power to the reader. Figure 8: Cheetah SE Reader Rear View Table 4: Connector Descriptions Connectors Description A: Ethernet RJ45 connector. Provides network connectivity for applications and browser based reader configuration. B: 9-pin Molex Ground, Power, Bus, RS485, Supervised Inputs. See "FICAM/OSDP Wiring" on page 9 and "RM Wiring" on page 10. C: 6-pin Molex Bus, Relays, Output, Digital/Common Ground. See "FICAM/OSDP Wiring" on page 9 and "RM Wiring" on page 10. Molex 9-Pin Connector Properties Table 5 on Page 8 describes the 9-pin Molex keyed connector. Since the connector is keyed, it can only be inserted into the reader in one configuration, that is, with pin 9 on the left and with pin 1 on the right as you face the rear of the reader. 7

8 Table 5: 9-Pin Molex Connector Properties Pin # Pin Name Properties Wiring 1 GND Chassis Ground Chassis Ground that should be connected to Earth Ground by a low impedance path 2 PowerIN_N Power Negative line From negative terminal of power source 3 PowerIN_P Power Positive line From positive terminal of power source 4 5Vdc 5 VDC outputs at 0.5 amps Optional 5Vdc to external connector 5 RS485-A EIA-485 differential line 1: '+', TxD- /RxD-, or inverting pin 6 RS485-B EIA-485 differential line 2:' ', TxD+/RxD+, or non-inverting pin To PACS Panel RS485 4-pin reader connector. To PACS Panel RS485 4-pin reader connector. 7 GND Signal Ground Reference 8 SUPRV_ INPUT1 9 SUPRV_ INPUT2 Supervised Input 1. Maximum length of 2000 ft (610 m) Supervised Input 2. Maximum length of 2000 ft (610 m) From PACS Panel From PACS Panel Molex 6-pin Connector Properties Table 6 on Page 8 describes the 6-pin Molex keyed connector. Since the connector is keyed, it can only be inserted into the reader in one configuration, that is, with pin 6 on the left and with pin 1 on the right as you face the rear of the reader. Table 6: 6-Pin Molex Connector Properties Pin # Pin Name Properties Wiring 1 5Vdc 5 VDC outputs at 0.5 amps Optional 5Vdc supplied to external connector 2 RELAY1_ COM Relay CO (Common) RLY: RELAY COMMON - typically used where the reader is independent of a PACS system. 3 RELAY_ NC Relay NC (Normally Closed) 4 RELAY_ NO Relay NO (Normally Open) RELAY NORMALLY CLOSED - typically used where the reader is independent of a PACS system. Relay can be used to control magnetic and electric strikes. RLY: RELAY NORMALLY OPEN - typically used where the reader is independent of a PACS system. Relay can be used to control magnetic and electric strikes. 5 CONN_ WOUT0 Output 0 For RM or OSDP to PACS or device 6 GND Signal Ground Reference Table 7 on Page 9 shows additional information regarding circuits. 8

9 Table 7: Circuits Circuit Voltage Current Power input 12 V 0.6 A Power input 24 V 0.3 A Relay Output (dry) 30 VDC 1 A 5 V Output (two connections provided) 5 V 0.5 A (combined maximum) Optical Relay (wet) 5 V 0.05 A Wiring Diagrams Wiring for FICAM/OSDP Connectivity Figure 9 on Page 9 shows an example of FICAM/OSDP wiring. Figure 11 on Page 10 shows wiring for supervised inputs. Figure 9: FICAM/OSDP Wiring Wiring for RM Connectivity Figure 10 on Page 10 shows an example of RM wiring. Figure 11 on Page 10 shows wiring for supervised inputs. 9

10 Figure 10: RM Wiring Wiring Supervised Inputs Figure 11 on Page 10 shows examples of wiring normally closed (NC) and normally open (NO) supervised inputs. The pin numbers refer to the 9-pin Molex connectors (J7) shown in Figure 9 on Page 9 and Figure 10 on Page 10. Figure 11: Examples of Supervised Inputs Setting Up the Reader The default or configured settings for the reader are shown in the reader LCD display. All settings can be changed through browser based administration, except the reader's LCD brightness, which is the only setting configurable at the reader. See Keypad Operation on Page 11 and Browser Based Administration on Page 12. To begin browser based administration, you must get the reader IP Address from the reader LCD display. 10

11 Keypad Operation To Display Configured Settings: Keys Status Screen Display 1. Press function keys F1 and F4 at same time to display the Status Screen. Pressing 1 will redisplay the current firmware version. 2. Press key 2 to display the reader's current IP address. 3. Press key 3 to display Ethernet Status. 4. Press key 4 to display the current Reader Address. 5. Press key 5 to display the current Reader Baud Rate. 6. Key 6 is not used. 7. Press key 7 to display Tamper Status. 11

12 Keys Status Screen Display 8. Press key 8 to display Supervised Inputs. Keys 9 and 0 are not used. Press # to exist the status menu. To Configure Reader Brightness 1. Press keys F2 and F4 simultaneously to display screen contrast setting. Sample text displays on line one; control keys display on line two. a. Use the F2 (for +) or F3 (for -) keys to increase or decrease the display contrast. Default Factory Settings Reader starts by reading a default behavioral profile "RM+CSN". Web user name set to admin ; password set to password IP set to Static IP address set to RM address set to 1 RM baud rate set to 9600 Screen brightness and contrast set to normal setting Browser Based Administration This section provides instructions for using browser-based administration to configure the reader. Network Connection Requirements For each new reader, you must set network parameters before using browser-based administration to complete the configuration across a TCP/IP network connection. Prior to connecting to the network: 1. Have the correct network settings. 2. Ensure the reader is properly wired for 12 Vdc power. 3. Ensure the Ethernet port of the reader is connected to the network. 4. Obtain the IP Address of the reader from its LCD display. See Keypad Operation on Page 11 12

13 Connecting to the Network All readers ship with unprotected access to Administration Mode. The default administrator user name is "admin" and the default password is "password". Additional administrators should be created and the password for the initial administrator should be changed for security purposes. From a web browser, connect to the reader's IP Address. The login screen displays. Figure 12: Login screen Enter the administrator user name and password. Default user name: admin Default password: password The Main Screen displays. Figure 13: Main screen Click on Set Profile to display the default profile: Menu of profile selections: 13

14 Select a profile from the dropdown menu. Click on Continue to configure additional parameters for that profile. Click on Save Profile to restart the reader with the changed profile parameters. Upon the reader restarting, log back in as administrator. Select Network from the main screen. Depending on the reader's setting for Static IP address or DHCP, a screen similar to one of the following is displayed: Figure 14: Ethernet Screens If you make changes to either network screen and select Update Settings, the reader will restart with the changed settings. After logging back in, selecting UTIL tab from main screen displays the utility options. 14

15 From the UTIL menu, to change the browser based administration password, select WEB PASSWORD. To restart the reader with the changed password, select Update Settings. To update reader firmware, select UPDATE and supply the location of a new firmware file. Click the Upload File button to upload the file to the reader and update the firmware. The reader will then restart. To display options to download, upload or restore a configuration file, select CONFIGURATION FILE. To reset the reader to factory defaults, select RESET TO DEFAULT CONFIGURATION. Innometriks Cheetah SE Reader Quick Start Guide To restart the reader select RESTART READER, and after the reader restarts the login screen will be again displayed. 15

16 Support Information Innometriks Support Contact Information Innometriks Inc. 6 Technology Park Drive Westford, MA support@innometriks.com Phone: Use your FTP client and provided credentials to access the ftp.innometriks.com site to download the puchased applications and documentation. Additional Information Canadian Radio Emissions Requirements The digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le present appareil numerique n emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la class A prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada. FCC Digital Device Limitations Radio and Television Interference This equipment has been tested and found to comply with the limits for a digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and television reception. Caution: Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate this equipment. Cheetah SE Reader is a trademark of Johnson Controls. The trademarks, logos, and service marks displayed on this document are registered in the United States [or other countries]. Any misuse of the trademarks is strictly prohibited and Johnson Controls will aggressively enforce its intellectual property rights to the fullest extent of the law, including pursuit of criminal prosecution wherever necessary. All trademarks not owned by Johnson Controls are the property of their respective owners, and are used with permission or allowed under applicable laws. Products offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your regional sales manager. This manual is proprietary information of Johnson Controls. Unauthorized reproduction of any portion of this manual is prohibited. The material in this manual is for information purposes only. It is subject to change without notice. Johnson Controls assumes no responsibility for incorrect information this manual may contain Johnson Controls All rights reserved. 16

Innometriks Cheetah SE Reader User Guide

Innometriks Cheetah SE Reader User Guide Innometriks Cheetah SE Reader User Guide 8200-1558-02 B0 AUGUST 2018 6 Technology Park Drive Westford, MA 01886 www.innometriks.com Phone: +1 760-542-0200 Canadian Radio Emissions Requirements The digital

More information

Quick Start Installation Guide

Quick Start Installation Guide RM-iCLASS Series Quick Start Installation Guide Version C0 Document Part Number UM-208 June 2009 OVERVIEW The RM-iClass Quick Start Installation Guide provides a summary of installation and connection

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A Installation Guide Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit Issue: 052209 PN: 883884-11L Rev. A ii Copyright Notice 2009, Wyse Technology Inc. All rights reserved. This manual and the software

More information

INNOMETRIKS INC. Rhino Quick Start Guide

INNOMETRIKS INC. Rhino Quick Start Guide INNOMETRIKS INC Rhino Quick Start Guide Rhino Quick Start Guide Innometriks Inc Fallbrook, Ca. 92028 Phone 760-207-6908 Sales: Sales@innometriksinc.com General Information: Info@innometriksinc.com Customer

More information

Allworx Tx 92/24 Telephone Expander Installation Guide

Allworx Tx 92/24 Telephone Expander Installation Guide Allworx Tx 92/24 Telephone Expander Installation Guide No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical,

More information

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude Start Here The NETGEAR Model DS108 Dual Speed Hub is a network hub that enables users to mix and match 10 and 100 megabits per second (Mbps) devices on the same network. This capability eliminates the

More information

1.0 Description. 2.0 Unpacking. 3.0 Installation

1.0 Description. 2.0 Unpacking. 3.0 Installation ES-H, ES-HA Series Precision Balance Thank you for purchasing the Model ES-H and ES-HA precision balance. Please read all operating instructions carefully before using and note the following items to ensure

More information

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents. User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply

More information

NSD/M1 Installation Instructions

NSD/M1 Installation Instructions NSD/M1 Installation Instructions DOC. #560502200 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set forth in UL

More information

PC Media Converter, Switching (TP-TX/FX)

PC Media Converter, Switching (TP-TX/FX) April 2006 LH6620C LH6621C LH6622C LH6623C PC Media Converter, Switching (TP-TX/FX) Copyright 2006. Black Box Corporation. All rights reserved 1000 Park Drive * Lawrence, PA. 35055-1018 * 724-746-5500

More information

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs VDSL LAN Extender Products LMC5220A (Standalone Set, AC) LMC5221A (Standalone, AC, CO Unit) LMC5222A (Standalone, AC, CPE Unit) LMC5223A (Standalone Set, Multi-Power) LMC5224A (Standalone, Multi-Power,

More information

QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules

QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules APPLICATION PRODUCT DATA The QS7800A Network Interface ControlBus Module allows remote monitoring and diagnostics of the 7800 SERIES

More information

Gallagher T20 Reader. Installation Note. The Gallagher T20 Reader

Gallagher T20 Reader. Installation Note. The Gallagher T20 Reader ATTENTION: This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any servicing. The The is a smart card proximity

More information

NCH-1000 (Multiple Breaker Types) Installation Instructions

NCH-1000 (Multiple Breaker Types) Installation Instructions 20M1 12345678 NCH-1000 (Multiple Breaker Types) Installation Instructions DOC. #560502100 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance

More information

RS-232 HS4 JANUARY 1997 IC131C CUSTOMER SUPPORT INFORMATION

RS-232 HS4 JANUARY 1997 IC131C CUSTOMER SUPPORT INFORMATION JANUARY 199 IC131C RS-3 HS CUSTOER SUPPORT INFORATION Order toll-free in the U.S. hours, A.. onday to midnight Friday: 8-8-BBOX FREE technical support, hours a day, days a week: Call --00 or fax --0 ail

More information

2DScan TM Barcode Scanner

2DScan TM Barcode Scanner 2DScan TM Barcode Scanner Quick Start Manual Default Check Version FCC WARNING STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part

More information

7800 SERIES S7810B Multi-Drop Switch Module

7800 SERIES S7810B Multi-Drop Switch Module 7800 SERIES S7810B Multi-Drop Switch Module PRODUCT DATA APPLICATION The Honeywell 7800 SERIES is a microprocessor-based integrated burner control for automatically fired gas, oil or combination fuel single-burner

More information

ADL-100 Operator s Manual

ADL-100 Operator s Manual 040604-510896-(01) ADL-100 Operator s Manual For Use With the Accent Disc Laminator 2004 All rights reserved. Notices: The information in this document is subject to change without notice. NO WARRANTY

More information

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before

More information

FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING)

FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING) JANUARY 2008 Model# SW1006A FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING) CUSTOMER Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical support, 24 hours a day,

More information

FIBER OPTIC A/B/C/D SWITCH (LATCHING)

FIBER OPTIC A/B/C/D SWITCH (LATCHING) JANUARY 2008 Model# SW1005A FIBER OPTIC A/B/C/D SWITCH (LATCHING) CUSTOMER Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical support, 24 hours a day, 7 days

More information

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis The Transition Networks CPSMC0200-2x0 series dual-slot PointSystem chassis is designed for installation of one or two selectable Transition Networks

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

RS-232/RS-422 Optical Isolator

RS-232/RS-422 Optical Isolator MAY 1998 IC457A-F IC457A-M RS-232/RS-422 Optical Isolator CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours

More information

Installation Instructions RF5010 and RF5210

Installation Instructions RF5010 and RF5210 Installation Instructions RF5010 and RF5210 HES, Inc. 22630 N. 17th Ave. Phoenix, AZ 85027 800-626-7590 1 Product Description Dimensions Orientation Compatibility Access Control Systems Proximity Cards

More information

Infosystem Remote Touchscreen Installation Instructions

Infosystem Remote Touchscreen Installation Instructions Infosystem Remote Touchscreen Installation Instructions DOC. #569102100 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements

More information

Installation Instructions RF5010 and RF5210

Installation Instructions RF5010 and RF5210 Installation Instructions RF5010 and RF5210 HES, Inc. 2260 N. 17th Ave. Phoenix, AZ 85027 800-626-7590 1 Product Description Dimensions Orientation Compatibility Access Control Systems Proximity Cards

More information

Rack Input Module Installation Instructions

Rack Input Module Installation Instructions Rack Input Module Installation Instructions DOC. #560105000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set

More information

H3-EM Electronic Swinghandle Operating Instructions

H3-EM Electronic Swinghandle Operating Instructions H3-EM-66-100 Electronic Swinghandle Operating Instructions Package Contents H3-EM-66-x00 Electronic Swinghandle with RFID Reader (qty1) EM-0-45827 M3x25 POZIDRIV Mounting Screws (qty 4) EM-0-47151 M3x14

More information

QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules

QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules APPLICATION PRODUCT DATA The QS7800B Network Interface ControlBus Module allows remote monitoring and diagnostics

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS READ THIS MANUAL CAREFULLY! FAILURE TO INSTALL THIS EQUIPMENT PER THESE INSTRUCTIONS WILL VOID THE WARRANTY. AM16904-1 Rev. C pg. 1 of 12 SPECIAL NOTICES The following notices

More information

SYSNet QS7700A Network Interface ControlBus Module for BCS7700

SYSNet QS7700A Network Interface ControlBus Module for BCS7700 SYSNet QS7700A Network Interface ControlBus Module for BCS7700 FEATURES PRODUCT DATA Up to six ControlBus Modules per Network Interface Unit. Remote programming of nonsafety BCS 7700 values via the ControlBus

More information

Cat. No KT/B. Installation Data

Cat. No KT/B. Installation Data Cat. No. 1784-KT/B Installation Data The 1784-KT/B Communication Interface Module allows personal computers, workstations or terminals to communicate with Allen-Bradley processors and controllers, either

More information

Four Port RS-232 Serial Interface

Four Port RS-232 Serial Interface JUNE 000 IC1C IC181C Four Port RS-3 Serial Interface CUSTOER SUPPORT INFORATION Order toll-free in the U.S. hours, A.. onday to midnight Friday: 8-8-BBOX FREE technical support, hours a day, days a week:

More information

Keyboard Display Unit

Keyboard Display Unit Keyboard Display Unit 980010-001 Rev.E Page 1 GENERAL INSTRUCTIONS The Keyboard Display Unit (KDU) is a terminal unit that interfaces with Eltron s LP+, TLP and P2242 Series printers in a stand-alone capacity.

More information

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1. Document Number: 466-1632 Rev. B September 2000 Product Summary The ITI SuperBus 2000 2 x 20 LCD (liquid crystal display) Alphanumeric Touchpad gives you complete on-site system programming and operation

More information

CHS 7Ci. Bluetooth Cordless Barcode Scanner. Quick Start Guide

CHS 7Ci. Bluetooth Cordless Barcode Scanner.  Quick Start Guide Quick Start Guide CHS 7Ci Bluetooth Cordless Barcode Scanner www.socketmobile.com PACKAGE CONTENTS Product Information Product label Blue/Green/Red LED Scanner head Trigger button CHS 7Ci Lanyard NiMH

More information

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input. LMC5103A-R2 1-slot Multipower Desktop Chassis (Module Not Included) This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power

More information

Quick Start Installation Guide

Quick Start Installation Guide RM-DCM-2 Quick Start Installation Guide Version G0 Document Part Number UM-215 May 2010 OVERVIEW The RM-DCM-2 is a UL294 Listed and UL1076 Listed door control module that includes the RM-4E Reader Module

More information

Edgeport. USB Expansion Modules. Installation Guide

Edgeport. USB Expansion Modules. Installation Guide Edgeport USB Expansion Modules Installation Guide Revision history 90000403 Revision Date Description J June, 2009 Updated the product CD. K July, 2013 Removed the DoC section. L November, 2013 Updated

More information

Installation Guide for. PCC Premier Precision Camera Controller. Document Rev. C

Installation Guide for. PCC Premier Precision Camera Controller. Document Rev. C Installation Guide for PCC Premier Precision Camera Controller Document 342-1136 Rev. C Contents About this Guide 1 Product Overview 2 Features 2 Unpacking the Camera Controller 3 Installation 4 Don t

More information

2-Port Serial-to-IP Ethernet Device Server - RS232

2-Port Serial-to-IP Ethernet Device Server - RS232 2-Port Serial-to-IP Ethernet Device Server - RS232 NETRS2322P *actual product may vary from photos FR: Guide de l utilisateur - fr.startech.com DE: Bedienungsanleitung - de.startech.com ES: Guía del usuario

More information

USB USB Data Transfer

USB USB Data Transfer DECEMBER 2000 IC149A-R2 USB USB Data Transfer USB to USB Data Transfer CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support,

More information

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax Copyright 2003. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 AUI to 10BASE-FL Transceiver MAY 2003 LE1603A CUSTOMER SUPPORT INFORMATION

More information

Installation Guide. Avigilon ACM Embedded Controller

Installation Guide. Avigilon ACM Embedded Controller Installation Guide Avigilon ACM Embedded Controller 2016, Avigilon Corporation. Portions 2003-2014 HID Global Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER and ACM

More information

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A Stacking Module AT-MCF2000S Installation Guide PN 613-000708 Rev A Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission

More information

Giga-MiniMc TX & RX USER MANUAL

Giga-MiniMc TX & RX USER MANUAL Giga-MiniMc 856-10730-TX & 856-10730-RX USER MANUAL Advantech B+B SmartWorx - Americas 707 Dayton Road Ottawa, IL 61350 USA Phone 1 (815) 433-5100 Fax 1 (815) 433-5105 Advantech B+B SmartWorx - Europe

More information

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide HARDWARE GUIDE Water Loop Controller C1000 Series Specifications and Operational Guide www.proloncontrols.com info@proloncontrols.com 17 510, rue Charles, Suite 100, Mirabel, QC, J7J 1X9 REV. 6.1.6 PL-HRDW-WLC-C1000-C/F-EN

More information

Support for Non-Ultra2 SCSI Devices

Support for Non-Ultra2 SCSI Devices 512030a.qxd 11/24/98 2:08 PM Page 1 INTRODUCTION With the SCSI Card 3950U2, you can connect up to 30 SCSI devices, such as hard disk drives, scanners, CD-ROM drives, and tape drives, to any IBM-compatible

More information

istar Pro Installation Guide

istar Pro Installation Guide istar Pro Installation Guide UM-241 Version A1 October 2010 istar Pro Installation Quick Start Guide System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general

More information

Mounting and Operating Instructions (Simple Programming) Art.No..: , published: 10/2003

Mounting and Operating Instructions (Simple Programming) Art.No..: , published: 10/2003 Mounting and Operating Instructions (Simple Programming) Art.No..: 732.29.125, published: 10/2003 Wall Terminal 2000 V.7 Art. No. Model Trans. Format Art. No. Model Trans. Format 917.01.101 Int., 1 Relay

More information

PETROL (P-SERIES), TTL, INSERTION READER TECHNICAL REFERENCE MANUAL

PETROL (P-SERIES), TTL, INSERTION READER TECHNICAL REFERENCE MANUAL PETROL (P-SERIES), TTL, INSERTION READER TECHNICAL REFERENCE MANUAL Manual Part Number 99875139 Rev 8 MAY 2003 REGISTERED TO ISO 9001:2000 20725 South Annalee Avenue Carson, CA 90746 Phone: (310) 631-8602

More information

Mobile UHF Reader. Quick Guide. For full user s manual, please contact your local distributor. Mobile UHF Reader Quick Guide (Rev2) P/N:

Mobile UHF Reader. Quick Guide. For full user s manual, please contact your local distributor. Mobile UHF Reader Quick Guide (Rev2) P/N: Mobile UHF Reader Quick Guide For full user s manual, please contact your local distributor. Mobile UHF Reader Quick Guide (Rev2) P/N: 8012-0064001 FCC WARNING STATEMENT This equipment has been tested

More information

INSTALLATION GUIDE ADAPTEC SCSI CARD ULTRA160 SCSI CONTROLLER

INSTALLATION GUIDE ADAPTEC SCSI CARD ULTRA160 SCSI CONTROLLER R INSTALLATION GUIDE ADAPTEC SCSI CARD 29160 ULTRA160 SCSI CONTROLLER Adaptec SCSI Card 29160 INTRODUCTION The Adaptec SCSI Card 29160 Ultra160 SCSI controller enables you to connect up to 15 SCSI devices

More information

Installer/User Guide

Installer/User Guide Installer/User Guide Avocent Corporation 4991 Corporate Drive Huntsville, Alabama 35805-6201 USA 256-430-4000 (Fax) 256-430-4030 http://www.avocent.com FCC Notification Warning: Changes or modifications

More information

Model Bulk Sampling Scale. User s Manual

Model Bulk Sampling Scale. User s Manual Model 7050 Bulk Sampling Scale User s Manual UNITED STATES This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits

More information

rcc.1081 Installation Instructions

rcc.1081 Installation Instructions rcc.1081 Installation Instructions Table of Contents Introduction...1 Specifications...2 Mounting...3 Wiring...5 Wiring Method...7 BACnet Network Wiring...8 Setting BACnet Address...9 Setting the BACnet

More information

10/100 Autosensing PC Media Converter

10/100 Autosensing PC Media Converter April 2006 LE6610C LE6611C LE6612C LE6613C 10/100 Autosensing PC Media Converter Copyright 2006. Black Box Corporation. All rights reserved 1000 Park Drive * Lawrence, PA. 35055-1018 * 724-746-5500 * Fax

More information

CSM200 Expansion Tray

CSM200 Expansion Tray CSM200 Expansion Tray Initial Setup Guide for SANtricity users or VTL environments EC1718-1-E3, Third Edition Proprietary Rights Notice This document contains proprietary information of LSI Logic Corporation

More information

Installation Guide AVA-2902E/I. PCI-to-Fast SCSI Host Adapters. PCI SCSI Host Adapter with Internal or External Connector

Installation Guide AVA-2902E/I. PCI-to-Fast SCSI Host Adapters. PCI SCSI Host Adapter with Internal or External Connector Installation Guide AVA-2902E/I PCI-to-Fast SCSI Host Adapters PCI SCSI Host Adapter with Internal or External Connector R 1 Installing the Host Adapter and SCSI Device WARNING: Before you start, turn OFF

More information

SGI Altix PA Expansion Module User s Guide

SGI Altix PA Expansion Module User s Guide SGI Altix PA Expansion Module User s Guide 007-4712-001 CONTRIBUTORS Written by Mark Schwenden Illustrated by Chrystie Danzer Production by Karen Jacobson Engineering contributions by Dick Brownell, Gary

More information

Verify Package Contents

Verify Package Contents Start Here Instructions in this guide are for users of Windows who are installing the Model EA101 USB Ethernet Adapter. For instructions on installing and verifying the Windows network driver, refer to

More information

IP7 -SS20. IP Paging Amplifier. Reference Manual

IP7 -SS20. IP Paging Amplifier. Reference Manual IP7 -SS20 IP Paging Amplifier Reference Manual This page left blank Table of Contents Overview...1 Specifications...2 IP7-SS20 Layout...3 LED Indicators...6 LEDs... 6 LED Status Table... 6 LAN Connector

More information

SCSI Fiber Optic Extender

SCSI Fiber Optic Extender Black Box Corporation The Source for Connectivity JUNE 1996 IC495A-R2 SCSI Fiber Optic Extender SCSI FIBER OPTIC EXTENDER LINK ACTIVE BUS ACTIVE LINK ERROR POWER CUSTOMER SUPPORT INFORMATION Call our Technical

More information

Safety and Radio-Frequency Interference

Safety and Radio-Frequency Interference FieldPoint Read Me First Safety and Radio-Frequency Interference This document contains safety instructions and information about the radio-frequency interference characteristics of the FieldPoint hardware.

More information

IP7 -SS40. IP Paging Amplifier. Reference Manual

IP7 -SS40. IP Paging Amplifier. Reference Manual IP7 -SS40 IP Paging Amplifier Reference Manual This page left blank Table of Contents Overview... 1 Specifications... 2 IP7-SS40 Layout... 3 LED Indicators... 6 LEDs... 6 LED Status Table... 6 LAN Connector

More information

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016 FX-DIS1710-0 Part No. 24-10240-17, Rev. B Issued April 2016 Applications The FX-DIS1710 Local Controller Display is a stand-alone display module designed for installation on the front panel of an enclosure.

More information

ATP1000 Touchpad/Display Installation Instructions

ATP1000 Touchpad/Display Installation Instructions ATP1000 Touchpad/Display Installation Instructions Product summary The ATP1000 lets you control all programming and operation of compatible security systems (see the Specifications section). The large

More information

Installation Guide DRAFTMF4100

Installation Guide DRAFTMF4100 Installation Guide MF4100 This Class B digital apparatus complies with Canadian ICES-003 Cet appareill numérique de la classes B est conform à la norme NMB-003 du Canada This device complies with Part

More information

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A AT-6102 IEEE 802.3af Universal Multi-voltage PoE Splitter Installation and User Guide PN 613-000635 Rev A Electrical Safety and Emissions Standards Standards: This product meets the following standards.

More information

RMB Peripheral Units Installation Guide

RMB Peripheral Units Installation Guide RMB Peripheral Units Installation Guide Part Number 65-000101 2011 by Kentrox, Inc. All rights reserved. Copyright 2011 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication

More information

INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP

INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP INTRODUCTION The Adaptec SCSI Card 29320LP enables you to connect up to 15 SCSI devices such as very large arrays of high-performance hard disk drives, external

More information

Cardax Prox Plus Mifare Reader

Cardax Prox Plus Mifare Reader Installation Note Cardax Prox Plus Mifare Reader CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning

More information

3M Wrist Strap and Ground Monitor 773. User s Guide

3M Wrist Strap and Ground Monitor 773. User s Guide 3M Wrist Strap and Ground Monitor 773 User s Guide Table of Contents Section Page Safety Information... 2 1 Description... 4 Overview... 4 Performance... 4 2 Installation... 5 Supplied Parts... 5 Wire

More information

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions 3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These

More information

Envoi Installation and Setup Instructions

Envoi Installation and Setup Instructions Envoi Installation and Setup Instructions DOC. #569068500 F 4/18/05 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set forth

More information

AN-310-RT-4L2W. 310 SERIES MULTI-WAN GIGABIT VPN ROUTERS Quick Start Guide

AN-310-RT-4L2W. 310 SERIES MULTI-WAN GIGABIT VPN ROUTERS Quick Start Guide AN-310-RT-4L2W 310 SERIES MULTI- GIGABIT VPN ROUTERS 2 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device,

More information

INNOMETRIKS INC. Rhino Implementation Guide

INNOMETRIKS INC. Rhino Implementation Guide INNOMETRIKS INC Rhino Implementation Guide Rhino Implementation Guide Innometriks Inc Fallbrook, Ca. 92028 Phone 760-542-0200 Sales: Sales@innometriksinc.com General Information: Info@innometriksinc.com

More information

Xpass S2. Installation Guide. Intelligent IP Access Control Reader EN XPS2 V1.11.

Xpass S2. Installation Guide. Intelligent IP Access Control Reader EN XPS2 V1.11. Intelligent IP Access Control Reader Installation Guide EN 101.00.XPS2 V1.11 www.supremainc.com Important Safety Information Carefully review the information within the user manual before installing or

More information

Operator s Manual For Use With the Signature III CD Color Printer or Inscripta Thermal CD Printer

Operator s Manual For Use With the Signature III CD Color Printer or Inscripta Thermal CD Printer Operator s Manual For Use With the Signature III CD Color Printer or Inscripta Thermal CD Printer Two Carlson Parkway North Plymouth, MN 55447-4446 U.S.A. Phone: 1-800-797-2772 763-475-6676 FAX: 763-475-6677

More information

NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement

NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement First Edition: December 2005 Last Revision: December 2005 Document # 103518-00 Legal Notices Disclaimer Information

More information

Multi-Messager USB by Nel-Tech Labs, Inc. Installation & User Manual

Multi-Messager USB by Nel-Tech Labs, Inc. Installation & User Manual Multi-Messager USB by Nel-Tech Labs, Inc. Installation & User Manual Index: Introduction... 3 Multi-Messager USB Layout Summary... 4-5 Installation... 6-9 Message Programming & Operation... 10 Warranty

More information

1206P (CTS ME-X.21) MODEM ELIMINATOR, X.21 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1206P-A

1206P (CTS ME-X.21) MODEM ELIMINATOR, X.21 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1206P-A Doc #: Part #: 07M-A MODEM ELIMINATOR, X.21 (CTS ME-X.21) INSTALLATI AND OPERATIS MANUAL An ISO-9001 Certified Company Copyright 2000 Patton Electronics Co., All Rights Reserved PATT ELECTRICS CO. INSTALLATI

More information

Operator s Handbook. Monarch FreshMarx 9417 Food Freshness System. TC9417OH Rev. AE 1/ Avery Dennison Corp. All rights reserved.

Operator s Handbook. Monarch FreshMarx 9417 Food Freshness System. TC9417OH Rev. AE 1/ Avery Dennison Corp. All rights reserved. Operator s Handbook Monarch FreshMarx 9417 Food Freshness System TC9417OH Rev. AE 1/2015 2013 Avery Dennison Corp. All rights reserved. Each product and program carries a respective written warranty, the

More information

Connectivity Peripherals User s Guide. Point 510 Point 1600

Connectivity Peripherals User s Guide. Point 510 Point 1600 Connectivity Peripherals User s Guide Point 510 Point 1600 Connectivity Peripherals User s Guide Point 510 Point 1600 Fujitsu Personal Systems, Inc. has made every effort to ensure the accuracy and completeness

More information

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board *P516-097* P516-097 PIB300 and PIB301 User Guide Installation and operation instructions for Panel Interface Board Para el idioma español, navegue hacia www.schlage.com/support Pour la portion française,

More information

Mini Wireless Barcode Reader Quick Guide

Mini Wireless Barcode Reader Quick Guide Mini Wireless Barcode Reader Quick Guide Full user s manual is available on the enclosed CD. Mini Wireless Barcode Reader Quick Guide P/N: 8002-0028*00 FCC WARNING STATEMENT This equipment has been tested

More information

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date: CU8860-0000 USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date: 2006-02-20 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation 1 1.1.1 Liability Conditions 1 1.1.2 Conditions

More information

AT-GS950/16 AT-GS950/24

AT-GS950/16 AT-GS950/24 Gigabit Ethernet Smart Switches AT-GS950/16 AT-GS950/24 Installation Guide 613-000190 Rev. B Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without

More information

Home Security Camera icamera-1000

Home Security Camera icamera-1000 Home Security Camera icamera-1000 User Guide Table of Contents CHAPTER 1 INTRODUCTION... 1 Package Contents... 1 Features... 1 LEDs... 2 CHAPTER 2 INITIAL INSTALLATION... 4 Requirements... 4 Procedure...

More information

3174/3274 I-Mux FEBRUARY 1993 MX330A-C MX330A-D CUSTOMER SUPPORT INFORMATION

3174/3274 I-Mux FEBRUARY 1993 MX330A-C MX330A-D CUSTOMER SUPPORT INFORMATION FEBRUARY 1993 MX330A-C MX330A-D 3174/3274 I-Mux LINK CONTROLLER PORT FIBER OPTIC COPPER POWER TX RX TX RX DATA 0 DATA 1 DATA 2 DATA 3 DATA 3174/3274 I-MUX LINK MUX PORT FIBER OPTIC COPPER POWER TX RX TX

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i Assembly Guide Model 133i Radio Frequency Interference Notice (USA) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules,

More information

INSTALLATION AND SETUP GUIDE

INSTALLATION AND SETUP GUIDE INSTALLATION AND SETUP GUIDE idevices SMART HOME SOLUTIONS 1 REQUIRES A compatible idevices product idevices Connected app Controlling this product requires an iphone, ipad or ipod touch that supports

More information

ENCELIUM EXTEND Manager Wiring and installation manual Light is OSRAM

ENCELIUM EXTEND Manager Wiring and installation manual Light is OSRAM www.osram.us/extend ENCELIUM EXTEND Manager Wiring and installation manual Light is OSRAM Overview The ENCELIUM EXTEND Manager is a gateway that interfaces to both IT equipment (servers, LAN, etc) and

More information

Operating Instructions

Operating Instructions 028028 Operating Instructions Monarch 939i Intelligent Keyboard for use with 9416 XL, 9906, ADTP1, and ADTP2 TC0939IOI Rev. AN 5/17 2004 Avery Dennison Corp. All rights reserved. Each product and program

More information

ImproX IXP20 Controller INSTALLATION MANUAL

ImproX IXP20 Controller INSTALLATION MANUAL MODEL NUMBER: ISC920-0-0-GB-XX ISC921-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

Gallagher T12 Reader. Installa on Note. The Gallagher T12 Reader

Gallagher T12 Reader. Installa on Note. The Gallagher T12 Reader ATTENTION: This equipment contains components that can be damaged by electrosta c discharge. Ensure both you and the equipment are earthed before beginning any servicing. The The is a smart card proximity

More information

KP7 Keypad Quick Install Guide

KP7 Keypad Quick Install Guide KP7 Keypad Quick Install Guide English Thank you for including the KP7, 7 button keypad, as part of the user interface strategy for your customer. The KP7 has been designed to provide years of trouble

More information