Signal conditioning instruments VEGASCAN 693. Product Information

Size: px
Start display at page:

Download "Signal conditioning instruments VEGASCAN 693. Product Information"

Transcription

1 Signal conditioning instruments VEGASCAN 693 Product Information

2 Content Content 1 Product description Type overview Mounting instructions Connecting to power supply 4.1 Preparing the connection Wiring plan Operation 5.1 Adjustment on VEGASCAN Adjustment with PACTware Visualisation and measured value enquiry Application examples Technical data Dimensions Product code Take note of safety instructions for Ex applications Please note the Ex specific safety information which you will find on our homepage and which come with the appropriate instrument with Ex approval. In hazardous areas you should take note of the appropriate regulations, conformity and type approval certificates of the sensors and power supply units. Each VEGASCAN 693 with Ex approval is an associated, intrinsically safe instrument and must not be installed in hazardous areas. 2 Signal conditioning instruments

3 Product description 1 Product description Functional principle In continuous measurement, the level in a vessel is detected by a sensor and then transferred to the VEGASCAN 693 signal conditioning instrument for further processing. Through an adjustment, the measured value can be adapted to the individual circumstances. The requested measurement parameter is indicated in the display and made available to the integrated web server and the interfaces for further processing. Hence the measuring signal can be displayed locally or remotely via HTML browser or an additional visualisation software. Area of application In conjunction with the appropriate sensors, VEGASCAN 693 signal conditioning instruments can be used in a variety of applications: l Level measurement l Gauge measurement l Process pressure measurement l Distance measurement l Temperature measurement l Remote enquiry l Stocktaking l VMI (Vendor Managed Inventory) VEGASCAN 693 also serves as (Ex) power supply unit for the connected sensors (active input). Power supply is carried on the same two-wire cable. As an option, a second input without sensor power supply (passive input) is available, enabling the connection of transmitters with own supply voltage (e. g. sensors in fourwire version). Depending on the instrument type, up to five independent sensors can be connected and their measured values processed. Safety The integrated fault monitoring detects faults of VEGASCAN 693 as well as those of connected sensors. If such a fault is detected, the integrated fail safe relay deenergises and a fault signal is displayed via the LEDs on the front panel. The instrument has the following approvals: l Ex approval as auxiliary, intrinsically safe instrument Operation Adjustment can be carried out either via the integrated indicating and adjustment unit or via a Windows PC with appropriate software (e.g. PACTware ). The connection is made either via the interface converter VEGACONNECT or one of the integrated interfaces (RS232/Ethernet). Signal conditioning instruments 3

4 Type overview 2 Type overview VEGASCAN 693 (Ethernet) VEGASCAN 693 (RS232) Applications: Functions: Functionality via integrated interfaces: General level measurement, stocktaking, visualisation in the network by Visual VEGA or via integrated web server, VMI adjustment, linearisation of individual vessel geometries, scaling for indication and digital output values easy connection to a network via Ethernet, transmission of messages and measured values via , easy setup via PC Sensor input: 15 HART sensors with/without transmitter power supply (5 with Ex) Outputs: Ethernet interface RS232 interface Indication on the instrument: Graphics-capable clear text indication with background lighting general level measurement, stocktaking, remote enquiry via modem by Visual VEGA, VMI adjustment, linearisation of individual vessel geometries, scaling for indication and digital output values remote enquiry by easy modem connection via RS232, suitable for analogue, ISDN and cellular phones, automatic internet dial-up and transmission of messages and measured values via , easy setup via PC 15 HART sensors with/without transmitter power supply (5 with Ex) Graphics-capable clear text indication with background lighting 4 Signal conditioning instruments

5 Mounting instructions 3 Mounting instructions Installation location Each series 600 instrument consists of the actual signal conditioninginstrument as well as a plug-in socket for carrier rail mounting. Because it has protection class IP 30 or IP 20, the instrument is intended to be used in switching cabinets. Mounting The plug-in socket is constructed for carrier rail mounting according to EN Power supply is connected to terminals 17 and 18. For neighbouring series 600 signal conditioning instruments, it is possible to continue connection L1 and N directly via the supplied bridges A o VEGA B o C o 1 o 2 o 3 o o o o 7 o 8 o 9 o o N o L1 12 o A o VEGA B o C o 1 o 2 o 3 o 4 o 5 o 6 o 7 o 8 o 9 o 10 o N 11 o L1 12 o A VEGASCAN 693 in Ex version is an auxiliary, intrinsically safe instrument and must not be installed in explosion-endangered areas. Before setup, the Ex separating chamber must be attached (as shown below) with Ex versions. Safe operation can be only ensured if the operating instructions manual and the EG type approval certificate are observed. VEGASCAN 693 must not be opened. Fig. 1: Plug-in socket VEGASCAN Ex separating chamber 2 Ex coded pin with Ex versions 3 Type coded pin for VEGASCAN Bridges for looping the power supply Instrument coding All series 600 signal conditioning instruments are provided with different gaps dependent on type and version (mechanical coding). The plug-in socket is provided with coded pins that can be inserted to prevent accidental interchanging of the various instrument types. With a VEGASCAN 693 in Ex version, the supplied coded pins (type coded pin and Ex coded pin) must be inserted by the user according to the below chart. Signal conditioning instruments 5

6 Connecting to power supply 4 Connecting to power supply 4.1 Preparing the connection 4.2 Wiring plan Note safety instructions Always keep in mind the following safety instructions: l Connect only in the complete absence of line voltage l If overvoltage surges are expected, overvoltage arresters should be installed Take note of safety instructions for Ex applications In hazardous areas you should take note of the appropriate regulations, conformity and type approval certificates of the sensors and power supply units Select power supply The power supply can be V AC, 50/60 Hz or V DC L1 N Selecting connection cable Power supply of VEGASCAN 693 is connected with standard cable according to the national installation standards. Standard two-wire cable without screening can be used to connect sensors. If electromagnetic interference is expected, screened cable must be used. Cable screening and grounding Connect the cable screen on both ends to ground potential. In the sensor, the screen must be connected directly to the internal ground terminal. The ground terminal outside on the housing must be connected to the potential equalisation. If potential equalisation currents are expected, the screen connection on VEGASCAN 693 must be made via a ceramic capacitor (e. g. 1 nf, 1500 V). The low frequency potential equalisation currents are thus suppressed, but the protective effect against high frequency interference signals remains. Select connection cable for Ex applications Take note of the corresponding installation regulations for Ex applications. In particular, make sure that no potential equalisation currents flow over the cable screen. In case of grounding on both sides this can be achieved by the use of a capacitor or a separate potential equalisation. Fig. 2: Wiring plan VEGASCAN 693 with two-wire sensors 1 Measurement data input with sensor supply (active input) 2 Measurement data input (passive input), not in Ex ia 3 Internal fail safe relay 4 Distributor 5 Voltage supply of VEGASCAN HART two-wire sensor with Multidrop address 1 7 HART two-wire sensor with Multidrop address 2 8 HART two-wire sensor with Multidrop address 3 Note: VEGASCAN 693 is designed for connection of up to 15 HART sensors (5 with Ex). Because they are accessed via different addresses in the HART multidrop mode, all sensors must be connected to the same sensor input terminals. These are either terminals 1/2 (active input) or terminals 3/4 (passive input). Mixed operation of active and passive input is not possible. Since this is a digital bus system, only one two-wire cable should lead to the sensors. A distributor can then be connected directly forward of the sensors. Information: l On the active input (terminal 1/2), VEGASCAN 693 provides the power for the connected sensors. Power supply and measurement data are transmitted over the same two-wire cable. This mode is provided for connection of measuring transducers without separate power supply (sensors in two-wire version). l On the passive input (terminals 3/4), the sensors are not powered - only the measured value is transmitted. This input is for sensors with their own, separate power supply (sensors in four-wire version). Connection and operation in Ex ia on the passive input is not possible. 6 Signal conditioning instruments

7 Operation 5 Operation 5.1 Adjustment on VEGASCAN The integrated indicating and adjustment unit is used for measured value display, adjustment and diagnosis of VEGASCAN 693 as well as the connected sensors. The indication and adjustment is carried out via the clear, graphic-capable display with background lighting as well as four keys in the front. The adjustment menu with selectable language is clearly structured and enables easy setup. Certain adjustment options are not possible or only partially available with the integrated indicating and adjustment unit. These are e.g. web server and functions. For such applications, the use of PACTware with appropriate DTMs is recommended. The entered parameters are generally saved in VEGASCAN 693, optionally also in PACTware on the PC. COM on ESC VEGASCAN 693 Fig. 3: Indicating and adjustment elements LC display 2 Adjustment keys 3 Communication interface for VEGACONNECT 4 Status indication operation 5 Status indication fail safe relay 6 Status indication interface activity OK Ser. No Adjustment with PACTware PACTware /DTM All series 600 signal conditioning instruments can be also adjusted via a Windows PC. You will need the configuration software PACTware and a suitable instrument driver (DTM) according to the FDT standard. In addition, the VEGA DTMs can be integrated in other frame applications according to FDT standard. For connection, either the interface converter VEGA- CONNECT or the RS232/Ethernet interface with appropriate cable is required. All currently available VEGA DTMs are provided in a DTM Collection with the current PACTware version on CD. This CD is available from the respective VEGA agency for a token fee. The basic version of this DTM Collection incl. PACTware is also available as a free-of-charge download from the Internet. The professional version also includes saving and printing of project documentation. A DTM licence for the respective instrument family can be purchased via the responsible VEGA agency. Connection of the PC via VEGACONNECT For temporary connection of the PC, e.g. for parameter adjustment, the connection can be made via the interface converter VEGACONNECT. The necessary I²C interface in the front of VEGASCAN 693 is available with all instrument versions. On the computer, connection is made via the RS232 interface. If this is not available on your PC or already occupied, it is also possible to use a USB-RS232 adapter (e. g. article no ). Key functions l [OK] key: - Move to the menu overview - Confirm selected menu - Edit parameter - Save value Fig. 4: Connection via VEGACONNECT 1 RS232 interface of the PC 2 I²C adapter cable for VEGACONNECT 3 (article no ) 3 VEGASCAN 693 l l l [->] key to select: - menu change - list entry - Select editing position [+] key: - Change value of the parameter [ESC] key: - interrupt input - jump to the next higher menu Connection of the PC via RS232 Via the RS232 interface, direct parameter adjustment and measured value enquiry of the instrument can be carried out via PACTware. Use the RS232 modem connection cable included in the delivery and an additionally connectednull modem cable (e. g. article no. LOG ). If there is no RS232 interface available on the PC or if it is already occupied, you can also use a USB-RS232 adapter (e.g. article no ). Signal conditioning instruments 7

8 Operation Fig. 5: Connection of the PC via RS232 1 RS232 interface of the PC 2 RS232 interlink cable (article no. LOG ) 3 RS232 modem connection cable (in the scope of delivery) 4 RS232 interface of VEGASCAN VEGASCAN 693 Connection of the modem via RS232 The RS232 interface is particularly suitable for easy modem connection. External analogue, ISDN and GSM modems with standard interface can be used. The necessary RS232 modem connection cable is in the scope of delivery of VEGASCAN 693. Via the software Visual VEGA, remote enquiry of the measured values and further processing are possible. As an alternative, also the independent, time or event-controlled transmission of measured values via is possible. A remote parameter adjustment of VEGASCAN 693 and the connected sensors is also possible with PACTware. 3 Fig. 6: Connection of the modem via RS232 1 Analogue, ISDN or GSM modem with RS232 interface 2 RS232 modem connection cable (in the scope of delivery) 3 RS232 interface of VEGASCAN VEGASCAN Fig. 7: Connection of the PC via Ethernet 1 Ethernet interface of the PC 2 Ethernet connection cable (Cross-Over cable) 3 Ethernet interface of VEGASCAN VEGASCAN Visualisation and measured value enquiry For visualisation or remote enquiry, the VEGASCAN 693 signal conditioning instruments are optionally equipped with an RS232 or Ethernet interface. RS232 interface The RS232 interface is suitable for simple modem connection to PACTware or Visual VEGA. External analogue, ISDN and GSM modems can be used for this purpose. Ethernet interface With the Ethernet interface, VEGASCAN 693 can be connected directly to an existing PC network. An own IP address is assigned to each VEGASCAN 693, under which it can be reached from everywhere in the network. Web browser The integrated web server can make the measured values available to any individual user in the company network. The data is presented as an HTML chart in a standard browser (e.g. Internet Explorer). Connection of the PC via Ethernet With the Ethernet interface, VEGASCAN 693 can be connected directly to an existing PC network. Any standard patch cable can be used. A cross-over cable must be used when connecting a VEGASCAN 693 directly to the PC. Each VEGASCAN 693 then gets its own IP address under which it can be accessed from anywhere in the network. The parameter adjustment of the instrument via PACTware can be carried out from any PC. The measured values can be made available to individual users within the company network as HTML chart. As an alternative, also the independent, time or event-controlled transmission of measured values via is possible. For more comprehensive requirements, it is recommended using the Visual VEGA software for measured value enquiry, processing and visualisation. 8 Signal conditioning instruments

9 Operation transmission When equipped with an Ethernet interface, the VEGASCAN 693 signal conditioning instruments can send s via an existing, company-internal mail server. With the RS232 interface and modem, the transmission is made via DFÜ network throughan external and Internet Provider. The transmission can be event or time-controlled. The transmission of fault messages is also possible. Visual VEGA Visual VEGA is a software for automatic enquiry of measured values, indication and archiving. The enquiry of measured values can be made via RS232, Ethernet or modem. The presentation can be divided in groups and displayed as bar graph, as a chart or as line graph of the history data. If certain thresholds are reached, a message can be displayed or an /sms can be transmitted. Visual VEGA is network capable and can be installed on any number of PCs. Visual VEGA is particularly suitable if a large number of measured values, also from different locations, should be automatically retrieved and consolidated. Individual measured values, messages or faults can be sent automaticallyvia , fax or SMS. It is also possible to specify that only the measured values and messages required by the individual user are made available to him. Via the measured value archive, any historical level data can be recalled and used for tendency indication. 5.4 Application examples Stock management of a tank farm via network Requirement The stock of a tank farm should be measured and monitored continuously. The measured values should be made available to the scheduler and the sales department. In addition, a message should be triggered automatically if a level drops below a certain value. Solution One or several VEGASCAN 693 with Ethernet interface enquire cyclically the connected HART sensors. The measured values are processed in VEGASCAN 693 and transferred in the requested form and unit to the integrated web server. The measured values can be now displayed on the computer of every user in the company network. The necessary min. quantity is also entered for each vessel. An is sent to the respective person via the company-internal mail system if this level is decreased. Set up l Connection of the sensors and VEGASCAN 693 l Assignment of sensor HART addresses l Entry of IP address, host name, date/time on VEGASCAN 693 l Installation of PACTware and DTMs on individual network PC l Parameter adjustment of the sensors (e.g. false echo memory) via PACTware l Parameter adjustment of VEGASCAN 693 (adjustment, scaling, linearization) via PACTware l Setup of the web and mail server (see DTM online help) l Indication of measured values through web browser by entering the IP address of VEGASCAN 693 Stock management of several tank farms via modem Requirement A supplier wants to count the stock of the tank farms of his customers and supply them automatically, if necessary. Via an indication (updated several times a day) and access to the levels of the previous days and weeks, the requirement/consumption of his customers should be estimated and the deliveries planned accordingly. This ensures foresighted purchasing and better utilization of the trucks. In addition, a message should be sent if the levels fall below certain predefined minimum values. By doing this, he can guarantee his customers a continuous supply of raw materials for production processes, without the customer having to take care of the purchase and ordering. This ensures better customer loyalty and continuous orders. Solution A VEGASCAN 693 with standard interface and modem (conventional telephone network or GSM) is installed at the customer's location. From the supplier's location, Visual VEGA contacts at regular, predefined intervals all VEGASCAN 693 in the field and retrieves the current measured values. The indication receives the current levels of each customer as well as the values of the past 30 days in a line graph. Via the network, any number of persons can have these values displayed at their work station with Visual VEGA (server/client principle). For each measurement loop, a certain measured value threshold is defined in Visual VEGA. If the value falls short of this threshold, Visual VEGA generates an appropriate message on the PC, and if desired, also sends an to certain persons. Signal conditioning instruments 9

10 Technical data 6 Technical data General data Series Weight Housing materials Socket materials Connection terminals - Type of terminal Screw terminal - Max. wire cross-section 1.5 mm² (AWG 16) Module unit with plug-in socket for mounting on carrier rail 35 x 7.5 according to EN g (1.10 lbs) Noryl SE100, Lexan 920A Noryl SE100, Noryl SE1 GFN3 Voltage supply Operating voltage Max. power consumption V AC/DC, 50/60 Hz 12 VA; 7.5 W Sensor input Number of sensors 15 x VEGA HART sensors (5 x with Ex version) Type of input (selectable) 1) - Active input Sensor power supply by VEGASCAN Passive input sensors have an own power supply Measured value transmission - HART protocol (Multidrop) digital for VEGA HART sensors Terminal voltage - Non-Ex version approx. 22 V with 15 sensors (60 ma) - Ex version approx. 15 V with 5 sensors (20 ma) Current limitation approx. 85 ma (26 ma with Ex) Adjustment range HART sensor - Adjustment range ±10 % from sensor measuring range - min. adjustment delta 0.1 % from sensor measuring range Connection cable two-wire screened standard cable Fail safe relay Contact Floating spdt Contact material AgSnO2, hard gold-plated Turn-on voltage 10 mv DC, 250 V AC/DC Switching current 10 µa DC, 3 A AC, 1 A DC Breaking capacity 50 mw, 750 VA, 18 W bei U 60 V DC, 40 W bei U 40 V DC 2) Version with Ethernet interface Quantity Data transmission Plug connection 1 x, cannot be combined with RS232 10/100 Mbit RJ45 Version with RS232 interface Quantity Plug connection 1 x, cannot be combined with Ethernet RJ45 (modem connection cable on 9-pole D-SUB in the scope of delivery) Indications 1) 2) Measured value indication - graphic-capable LC display (50 x 25 mm), background lighting digital and quasianalogue indication - Max. indicating range LED displays - Status indication operating voltage 1 x LED green - Status indication fault signal 1 x LED red - Status indication interface activity 1 x LED green Selection is made via the terminals, a mixed operation active/passive is not possible. If inductive loads or stronger currents are switched through, the gold plating on the relay contact surface will be permanently damaged. The contact is then no longer suitable for switching low-level signal circuits. 10 Signal conditioning instruments

11 Technical data Operation Adjustment elements PC adjustment 4 x keys in the front for menu adjustment PACTware with VEGA DTM (DTM Collection) Ambient conditions Ambient temperature Storage and transport temperature C ( F) C ( F) Electrical protective measures Protection - Instrument IP 30 - Plug-in socket IP 20 Overvoltage category II Protection class II Electrical separating measures Reliable separation according to VDE 0106 part 1 between power supply, input and digital part - Reference voltage 250 V - Isolation resistance 3.75 kv Galvanic separation between relay output and digital part - Reference voltage 250 V - Isolation resistance 4 kv Potential separation between Ethernet interface and digital part - Reference voltage 50 V - Isolation resistance 1 kv Potential separation between RS232 interface and digital part - Reference voltage 50 V - Isolation resistance 50 V Approvals 3) ATEX II (1) GD, [EEx ia] IIC 3) Deviating data in Ex applications: see separate safety instructions. Signal conditioning instruments 11

12 Dimensions 7 Dimensions VEGASCAN mm (3 27/64") 55mm (2 11/64") COM ESC on OK Ser. No mm (4 21/64") 119mm (4 11/16") mm (5 1/8") 72mm (2 53/64") Fig. 8: Dimensions VEGASCAN Signal conditioning instruments

13 Product code 8 Product code Approval XX without CX ATEX II (1) G D [EEx ia] IIC Connection R RS 232 connection incl.data logger and connection cable E Ethernet incl. data logger SCAN693. Signal conditioning instruments 13

14 14 Signal conditioning instruments

15 Signal conditioning instruments 15

16 VEGA Grieshaber KG Am Hohenstein Schiltach Germany Phone Fax Subject to change without prior notice You can find at downloads of the following l operating instructions manuals l menu schematics l software l certificates l approvals and much, much more

VEGAMET 381 VEGAMET 624 VEGAMET 625

VEGAMET 381 VEGAMET 624 VEGAMET 625 Signal conditioning instruments VEGAMET 64 VEGAMET 65 Product Information Contents Contents Product description... 3 Type overview.... 4 3 Mounting instructions... 5 4 Connecting to voltage supply 4. Preparing

More information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information Signal conditioning instruments for level switches Conductive VEGATOR C VEGATOR VEGATOR Product Information Content Content Product description..........................................................................

More information

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information Separating and protective instruments Separating and protective instruments VEGATRENN 149AEx Separator type KFDO Barrier type 9001 Product Information Content Content 1 Product description..........................................................................

More information

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure Indication and Adjustment Product Information VEGADIS 61 Level Switching Pressure 2 VEGADIS 61 Contents Contents 1 Product description...4 1.1 Configuration... 4 1.2 Principle of operation... 4 1.3 Adjustment...

More information

Operating Instructions

Operating Instructions Operating Instructions t i SPAN NOT USED - - 4...20mA DISPLAY t i SPAN END POINT DISPLAY Ð - 4...20mA p Safety information, Note Ex area Safety information Please read this manual carefully, and also take

More information

Safety instructions VEGATOR 121, 122

Safety instructions VEGATOR 121, 122 Safety instructions Intrinsic safety IECEx TUN 14.0005X Document ID: 47471 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Installation... 4 Supplementary documentation:

More information

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Safety instructions. IECEx TUN Ex ia IIC T6 Gb Safety instructions ÜSB62-36G.C_* and ÜSB62-30W.C_* IECEx TUN 07.0002 Ex [ia Ga] IIC T6 Gb Ex ia IIC T6 Gb 0044 39878 Content 1 Area of applicability 3 2 General 3 3 Electrical data 3 3.1 Application conditions

More information

Operating Instructions VEGAMET 391. Signal conditioning and display instrument for level sensors ma/hart. Document ID: 36032

Operating Instructions VEGAMET 391. Signal conditioning and display instrument for level sensors ma/hart. Document ID: 36032 Operating Instructions Signal conditioning and display instrument for level sensors VEGAMET 391 4 20 ma/hart Document ID: 36032 2 Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group...

More information

Safety instructions Overvoltage protection B81-35

Safety instructions Overvoltage protection B81-35 Safety instructions Overvoltage protection B81-35 IECEx BVS 15.0084X Intrinsic safety Document ID: 51001 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 5 4 Application

More information

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES O U R P R O F E S S I O N MULTIFUNCTIONAL CURRENT CONTROLLED SWITCH MODULES MAIN FEATURES 4 20 ma input Relay output Rail mountable Intrinsically safe Associated

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

Operating Instructions VEGAMET 391. Signal conditioning and display instrument for level sensors ma/hart. Document ID: 36032

Operating Instructions VEGAMET 391. Signal conditioning and display instrument for level sensors ma/hart. Document ID: 36032 Operating Instructions Signal conditioning and display instrument for level sensors VEGAMET 391 4 20 ma/hart Document ID: 36032 2 Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target

More information

Operating Instructions SU 600 Ex

Operating Instructions SU 600 Ex Operating Instructions SU 600 Ex 4 20 ma signal conditioning instrument Document ID: 30653 2 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3 Symbols used... 3 2 For

More information

Indication and adjustment

Indication and adjustment Indication and adjustment Contents Page Application examples... 218 Explanations to the cover graphics... 219 f. Adjustment and visualisation software... 221 ff. VEGADIS... 225 ff. Moving coil ammeter...

More information

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications. Modular Housings for Hazardous Areas For transmission of 0(4)... 20-mA signals from hazardous areas or supply of intrinsically safe 2-wire transmitters. The Task The power supply/isolator is used to supply

More information

Product information Ultrasonic

Product information Ultrasonic Product information Ultrasonic Level measurement in liquids and bulk solids VEGASON 6 VEGASON 6 VEGASON 6 Document ID: 90 Contents Contents Measuring principle... Type overview... 4 Instrument selection...

More information

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376 Supplementary instructions Plug connector Harting HAN 8D for continuously measuring sensors Document ID: 30376 Contents Contents 1 For your safety 1.1 Appropriate use... 3 1.2 Impermissible use... 3 1.3

More information

Supplementary instructions. VEGADIS adapter. For connection of an external display and adjustment unit or a slave sensor. Document ID: 45250

Supplementary instructions. VEGADIS adapter. For connection of an external display and adjustment unit or a slave sensor. Document ID: 45250 Supplementary instructions VEGADIS adapter For connection of an external display and adjustment unit or a slave sensor Document ID: 45250 Contents Contents 1 For your safety 1.1 Appropriate use... 3 1.2

More information

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

4 â Active barrier RN221N with optional HART diagnosis. Technical Information Technical Information Active barrier with optional HART diagnosis Active barrier with power supply for safe separation of 4 to 20 ma current circuits Application Galvanic isolation of 4 to 20 ma current

More information

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505 Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

VEGA SOFTWARE AND DISPLAY INSTRUMENTS

VEGA SOFTWARE AND DISPLAY INSTRUMENTS Data Sheet VEGA SOFTWARE AND DISPLAY INSTRUMENTS Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Software and display instruments Area of application Calibration of and visualization

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

CPU module for zone 2 Series 9442/35

CPU module for zone 2 Series 9442/35 > Supports PROFIBUS DP, PROFINET, Modbus TCP and Ethernet/IP; incl. HART transmission > RS-485 (max. 12 Mbps) and Ethernet (max. 100 Mbps) interfaces > Extensive diagnostics based on NE 107 > Support of

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

Operating Instruction

Operating Instruction Level and Pressure Operating Instruction VEGAMET 64 00 + CONNECT 2 on VEGAMET 64 ESC OK Ser. No. 2345678 in out Contents Contents Safety information... 3 Product description. Function and configuration...

More information

VariTrans P Standard-Signal Isolators

VariTrans P Standard-Signal Isolators VariTrans Standard-Signal Isolators Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our works (carriage and insurance paid by sender). The professional

More information

PROFIBUS-PA Positioner Type 3785

PROFIBUS-PA Positioner Type 3785 PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,

More information

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456 Supplementary instructions Plug connector Harting HAN 7D For point level sensors Document ID: 446 Contents Contents For your safety.... Appropriate use.... General safety instructions.... Safety instructions

More information

Operating Instructions. VEGA DataViewer. Software for archive, administration and display of DTM data. Document ID: 51547

Operating Instructions. VEGA DataViewer. Software for archive, administration and display of DTM data. Document ID: 51547 Operating Instructions Software for archive, administration and display of DTM data VEGA DataViewer Document ID: 51547 Contents Contents 1 About this document... 3 1.1 Function... 3 1.2 Target group...

More information

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous

More information

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications. EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier

More information

Operating Instruction

Operating Instruction Level and Pressure Operating Instruction VEGASWING 71 A Contents Contents Safety information... 2 1 Product description 1.1 Function and configuration... 3 1.2 Functional principle... 3 1.3 Technical data...

More information

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values Technical Information Minilog RDL10 Measured value collector with 2 input channels for storing analog and digital values Application Data storage for termperature, humidity, pressure, flow, level, and

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380

Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380 Supplementary instructions Plug connector ISO 4400 for level sensors Document ID: 30380 Contents Contents For your safety. Appropriate use... 3.2 General safety instructions... 3.3 Safety instructions

More information

System Components Surge Arrester HAW 261 and HAW 262

System Components Surge Arrester HAW 261 and HAW 262 Technical Information TI 108F/00/en System Components Surge Arrester and Operating Instructions Part. No. 017166-1000 for power supply side for signal input side (2-wire) (2 and 3-wire) Application The

More information

MULTICHANNEL DATA RECORDERS

MULTICHANNEL DATA RECORDERS MULTICHANNEL DATA RECORDERS Introduction ma + V / mv RTD + - universal inputs + - TC universal inputs: RTD + TC or U + I (SRD-99) fixed inputs: RTD, TC, U, I (SRD-N16) 2 relay outputs memory up to 3 000

More information

Supplementary instructions. Plug connector ISO for continuously measuring sensors. Document ID: 30375

Supplementary instructions. Plug connector ISO for continuously measuring sensors. Document ID: 30375 Supplementary instructions Plug connector ISO 4400 for continuously measuring sensors Document ID: 30375 Contents Contents For your safety. Appropriate use... 3.2 Impermissible use... 3.3 General safety

More information

Product information. Hydrostatic. Submersible pressure transmitter VEGABAR 86 VEGABAR 87 VEGAWELL 52. Document ID: 45079

Product information. Hydrostatic. Submersible pressure transmitter VEGABAR 86 VEGABAR 87 VEGAWELL 52. Document ID: 45079 Product information Submersible pressure transmitter VEGABAR 86 VEGABAR 87 VEGAWELL Document ID: 079 Contents Contents Measuring principle... Type overview... Instrument selection... Selection criteria...

More information

Technical Information Promonitor NRF560

Technical Information Promonitor NRF560 TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo

More information

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications. Safety Barriers Description Safety barriers limit the energy fed to an intrinsically safe circuit so that neither sparks nor thermal effects (hot surfaces) can cause an explosion. CEAG safety barriers

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

Technical Information Fieldgate SFG500

Technical Information Fieldgate SFG500 TI00029S/04/EN/10.16 71324508 Products Solutions Services Technical Information Fieldgate SFG500 Smart Ethernet/PROFIBUS gateway Parallel access to PROFIBUS networks Monitoring of PROFIBUS and HART device

More information

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3. Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and

More information

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring

More information

SensoTrans DMS A 20220

SensoTrans DMS A 20220 ProLine Interface Technology Strain Gauge Transmitters The transmitter for strain gauge full bridges in a 6 mm housing. The Task In many different industrial applications strain gauges are used to continuously

More information

MID approval no. DE-08-MI004-PTB004 Date of release

MID approval no. DE-08-MI004-PTB004 Date of release 1. Identification Energy and Flow Computer Flow rate and energy calculator for liquids, gases and water steam E-DB-1000-700-01 MID approval no. DE-08-MI004-PTB004 Date of release 04.01.08 2. Area of Application

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

Isolating repeater IRU 420

Isolating repeater IRU 420 Isolating repeater IRU 420 Universal intrinsically safe isolating repeater of current signals 0/4 20 ma with option voltage output 0 10 V For supply sensors with output 0/4 20 ma in Galvanic separation

More information

MULTICHANNEL DATA RECORDERS

MULTICHANNEL DATA RECORDERS MULTICHANNEL DATA RECORDERS Introduction ma + V / mv RTD + - universal inputs + - TC universal inputs: RTD + TC or U + I (SRD-99) fixed inputs: RTD, TC, U, I (SRD-N16) 2 relay outputs memory up to 3 000

More information

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001 PROCESS AUTOMATION MANUAL Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001 With regard to the supply of products, the current issue of the following document is applicable: The general terms of delivery

More information

HART adapters. Data Sheet. HART FSK/PC modem USB Ex(Haz.) and Non-Ex(Haz.) applications

HART adapters. Data Sheet. HART FSK/PC modem USB Ex(Haz.) and Non-Ex(Haz.) applications Data Sheet HART adapters HART FSK/PC modem USB Ex(Haz.) and NonEx(Haz.) applications HART FSK/PC modem II RS 232C Ex(Haz.) and NonEx(Haz.) applications HART FSK programming set RS 232C with transmitter

More information

Intrinsically Safe Barriers

Intrinsically Safe Barriers Intrinsically Safe Barriers Description Page No. Safety Barriers 464-472 Din Rail Isolated Barriers 473-488 477 Intrinsically Safe Barriers Product Overview We have simplified intrinsic safety! Cooper

More information

Limit switches for Dial Thermometers and Pressure gauges

Limit switches for Dial Thermometers and Pressure gauges JJ Direct limit switches JJ Indirect limit switches JJ Multifunction relays Limit switches for Dial Thermometers and Pressure gauges DS_Limit_switches 08/2015 349 Limit switches Limit switches are optional

More information

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-PT100-UI(-SP)(-NC) Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection

More information

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating manual. Universal transmitter UT125.  Save for later reference. Companies / brands of GHM English Operating manual Universal transmitter UT125 Companies / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents page 1. Intended use (areas of application)... 3 1.1 Safety

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Easy Analog RNB130. Technical Information. Primary switched-mode power supply Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power

More information

PSI-MODEM-SHDSL/SERIAL

PSI-MODEM-SHDSL/SERIAL PSI-MODEM-/SERIAL -SERIAL permanent line modem Data sheet 104460_en_02 PHOENIX CONTACT 2011-12-06 1 Description The industrial SERIAL permanent line modem enables broadband networking of serial devices

More information

IB IL 24/48 DOR 2/W-XC-PAC

IB IL 24/48 DOR 2/W-XC-PAC Inline digital output terminal, version for extreme conditions, 2 relay PDTs Data sheet 8463_en_01 PHOENIX CONTACT 2015-08-12 1 Description The terminal is designed for use within an Inline station. It

More information

Temperature Converters

Temperature Converters TURCK Interface Technology Temperature measurement is a very common application, even in hazardous areas. The IM34 temperature converting device provides advanced diagnostics, versatility and convenience

More information

MED MI 1005 Network Isolators

MED MI 1005 Network Isolators MED MI 1005 Network Isolators General Network isolators protect patients and medical devices from excessive leakage currents that may flow through the data network. Every device connected to the network

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12 www.stahl.de > Fieldbus connection Industrial Ethernet PROFINET, Modbus TCP or EtherNet/IP with 100 MBit/s > Redundant Ethernet connection (Modbus TCP) is possible > Explosion protected, optical inherently

More information

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450 Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450 o Measuring of resistance of RTD sensors (Pt100, Pt1000, Ni100, Cu10,...) o Accuracy class up to: 0.5 o Programmable input

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

Product information. Radar. Level measurement in bulk solids VEGAPULS 67 VEGAPULS SR 68 VEGAPULS 68 VEGAPULS 69. Document ID: 29427

Product information. Radar. Level measurement in bulk solids VEGAPULS 67 VEGAPULS SR 68 VEGAPULS 68 VEGAPULS 69. Document ID: 29427 Product information Level measurement in bulk solids VEGAPULS 67 VEGAPULS SR 68 VEGAPULS 68 VEGAPULS 69 Document ID: 97 Contents Contents Measuring principle... Type overview... Instrument selection...

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description I/O extension module, 4 digital relay outputs INTERFACE Data sheet 104834_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DOR4-IFS I/O extension module can be used in conjunction with Radioline

More information

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.

More information

TEPI11 P/I signal converter

TEPI11 P/I signal converter Contents Data Sheet 10/18-0.15-EN Rev. A TEPI11 P/I signal converter Air pressure in current DMS sensor for gauge pressure Compact design Small dimensions, low weight Can be installed in any orientation

More information

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Data sheet 302040_en MTP300i-SIL-K Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Properties 2-wire temperature transmitter for DIN rails Galvanic isolated TC-input with cold-junction compensation

More information

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detecting angular positions of 0 to 360 P1-Ri-DSU35 positioning element included in delivery

More information

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12 0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring

More information

Fieldgate FXA320, FXA520 Gateway for remote monitoring of ma and HART measuring devices

Fieldgate FXA320, FXA520 Gateway for remote monitoring of ma and HART measuring devices Technical Information Fieldgate FXA320, FXA520 Gateway for remote monitoring of 4...20 ma and HART measuring devices Thanks to integrated time control, Fieldgates are suitable for all applications in which

More information

WirelessHART Adapter SWA70

WirelessHART Adapter SWA70 Technical Information WirelessHART Adapter SWA70 Intelligent WirelessHART interface module for connection to 4...20 ma/hart devices Application WirelessHART Adapter SWA70 is a battery powered, interface

More information

Electronic Temperature Controller. Instruction Manual Version

Electronic Temperature Controller. Instruction Manual Version Electronic Temperature Controller 701 Instruction Manual Version 1.00.01 Dear Customer, we have made up this operating manual in such a way that all necessary information about the product can be found

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs INTERFACE Data sheet 104832_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DAIO6-IFS I/O extension module can be

More information

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-UI-REL(-SP) Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.

More information

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~ Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

MINI MCR-SL-UI-2I(-SP)(-NC)

MINI MCR-SL-UI-2I(-SP)(-NC) Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the

More information

Process display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction.

Process display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction. Technical information TI 063R/09/en Mat. No. 510 00857 Process display RIA 251 Digital loop powered display for 4...20 ma current loops Application areas Plant and machine construction Control panels Laboratory

More information

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34) is dedicated for reliable monitoring of lubrication, hydraulic and insulation oils as well as diesel fuel. In addition to highly accurate measurement of water activity (a w ) and temperature (T), calculates

More information

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet Process Automation IS Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the problems associated with the

More information

PROCESS AUTOMATION MANUAL. Temperature Trip Amplifier. KFD2-GU-(Ex)1 ISO9001

PROCESS AUTOMATION MANUAL. Temperature Trip Amplifier. KFD2-GU-(Ex)1 ISO9001 PROCESS AUTOMATION MANUAL Temperature Trip Amplifier KFD2-GU-(Ex)1 ISO9001 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

JUMO mtron T Measuring, Control, and Automation System

JUMO mtron T Measuring, Control, and Automation System sales@jumo.co.uk info.us@jumo.net Data Sheet 705040 Page 1/8 JUMO mtron T Measuring, Control, and Automation System Router module Brief description The router module is used to achieve decentralization

More information

Flow Computer compart DXF 351. Universal Application for Gas, Steam and Liquids

Flow Computer compart DXF 351. Universal Application for Gas, Steam and Liquids Technical Information TI 032D/06/e Nr. 50072927 Flow Computer compart DXF 351 Universal Application for Gas, Steam and Liquids Easy Fast commissioning using Quick Setup and help functions E+H programming

More information

APPLICATION GUIDE. Interface Modules IM Series.

APPLICATION GUIDE. Interface Modules IM Series. Interface Modules IM Series APPLICATION GUIDE www.turck.com Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to

More information

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to

More information

DISOMAT T Weigh Transmitter

DISOMAT T Weigh Transmitter DISOMAT T Weigh Transmitter Digital weigh transmitter Single-ingredient feed control System-compatible through serial interface, analog output and binary inputs/outputs Suitable for multi-scale systems

More information

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2 Technical Data Communication Adapter Catalog Number 1719-AENTR I/O Module Catalog Numbers 1719-IJ, 1719-IBN8B, 1719-IF4HB, 1719-IR4B, 1719-IT4B, 1719-OB2, 1719-OB2L, 1719-CF4H Power Supply Catalog Number

More information

T EN TROVIS Electropneumatic Positioner

T EN TROVIS Electropneumatic Positioner T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.

More information

VariTrans P The Problem The variety of tasks results in a large number of different devices.

VariTrans P The Problem The variety of tasks results in a large number of different devices. Universal Isolation Amplifiers The Multimeter among the isolation amplifiers. With 480 switchable calibrated ranges and broad-range power supply. The broad-range power supply for all common supply voltages

More information

Fieldgate FXA320, FXA520

Fieldgate FXA320, FXA520 TI025S/04/en Technical Information Fieldgate FXA320, FXA520 Gateway for remote monitoring of 4...20 ma and HART measuring devices Thanks to integrated time control, Fieldgates are suitable for all applications

More information

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact Data sheet Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact The CT-ARS.11 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges

More information

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing. Standard-Signal Isolation Amplifiers The world s first 3-port standard signal isolator in a 6-mm modular housing. The Task Isolation and, if required, conversion of 0... 20 ma, 4... 20 ma, and 0... 10

More information