Allen-Bradley Replacements

Size: px
Start display at page:

Download "Allen-Bradley Replacements"

Transcription

1 PLC-5 DeviceNet Scanner Module 1771-SDN User Manual Allen-Bradley Replacements

2 Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and standards. The illustrations, charts, sample programs and layout examples shown in this guide are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Allen-Bradley does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication. Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application, Installation and Maintenance of Solid-State Control (available from your local Allen-Bradley office), describes some important differences between solid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication. Reproduction of the contents of this copyrighted publication, in whole or part, without written permission of Rockwell Automation, is prohibited. Throughout this manual we use notes to make you aware of safety considerations: ATTENTION! Identifies information about practices or circumstances that can lead to personal injury or death, property damage or economic loss Attention statements help you to: identify a hazard avoid a hazard recognize the consequences IMPORTANT Identifies information that is critical for successful application and understanding of the product. Allen-Bradley, Data Highway Plus, and PLC-5 are trademarks of Rockwell Automation. ControlNet is a trademark of ControlNet International, Ltd. DeviceNet is a trademark of Open DeviceNet Vendor Association (ODVA), Inc. Ethernet is a trademark of Digital Equipment Corporation, Intel, and Xerox Corporation. RSLinx, RSLogix 5, and RSNetWorx are trademarks of Rockwell Software. Windows 95/98 and Windows NT are trademarks of Microsoft Corporation.

3 European Communities (EC) Directive Compliance If this product has the CE mark it is approved for installation within the European Union and EEA regions. It has been designed and tested to meet the following directives. EMC Directive This product is tested to meet the Council Directive 89/336/EC Electromagnetic Compatibility (EMC) by applying the following standards, in whole or in part, documented in a technical construction file: EN EMC Generic Emission Standard, Part 2 Industrial Environment EN EMC Generic Immunity Standard, Part 2 Industrial Environment This product is intended for use in an industrial environment. Low Voltage Directive This product is tested to meet Council Directive 73/23/EEC Low Voltage, by applying the safety requirements of EN Programmable Controllers, Part 2 - Equipment Requirements and Tests. For specific information required by EN , see the appropriate sections in this publication, as well as the Allen-Bradley publication Industrial Automation Wiring and Grounding Guidelines For Noise Immunity, publication This equipment is classified as open equipment and must be mounted in an enclosure during operation to provide safety protection. Allen-Bradley Replacements

4

5 Preface About This User Manual Introduction This user manual is designed to provide you enough information to get a small example application up and running. Use this manual if you are knowledgeable about DeviceNet and PLC-5 products, but may not have used the products in conjunction. The information provided is a base; modify or expand the examples to suit your particular needs. The manual contains instructions on configuring a DeviceNet network using RSLinx and RSNetWorx for DeviceNet software. It also describes how to use the PLC-5 pass-through feature to communicate with the DeviceNet network for adjustment and tuning of network devices via other networks, including: ControlNet Ethernet Data Highway Plus (DH+) The example application demonstrates how to perform control on DeviceNet using a PLC-5 processor and the 1771-SDN module. You use RSLogix 5 programming software to create a ladder logic program to control a photoeye and a RediSTATION. IMPORTANT This User manual should be used in conjunction with the 1771-SDN DeviceNet Scanner Module Installation Instructions, publication The Installation Instructions contain important information on configuring your scanner. Allen-Bradley Replacements 1

6 P-2 About This User Manual Contents This user manual contains the following chapters: 1 Before You Begin go to Chapter 1 2 Planning Your Configuration go to Chapter 2 3 Setting Up the Hardware go to Chapter 3 4 Configuring the DeviceNet Network go to Chapter 4 5 Configuring DeviceNet From Another Network go to Chapter 5 6 Creating and Running the Application Program go to Chapter 6 7 Troubleshooting go to Chapter 7 Audience This manual is intended for control engineers and technicians who are installing, programming, and maintaining a control system that includes a PLC-5 processor communicating on a DeviceNet network through a 1771-SDN module. We assume that you: are developing a DeviceNet network using a PLC-5 processor in conjunction with the 1771 SDN scanner module know each of your device s I/O parameters and requirements understand PLC-5 processor programming and operation are experienced with the Microsoft Windows environment are familiar with RSNetWorx for DeviceNet software

7 About This User Manual P-3 The Example Application This manual describes how to set up an example application. The manual provides examples of each step of the setup, with references to other manuals for more details. System Components We used the following devices and software for the example application. For your own application, substitute your own devices to fit your needs. The recommended configurations in this user manual will help you set up the test system and get it working. Your eventual configuration will depend on your application. Note: If you use different software or fimware versions of these products some of your screens may appear slightly different from those shown in the example. (1) (2) Product Name Catalog Number Series Revision Qty Hardware 1 PLC-5C processor (1) 1785-L20C15, -L40C15, -L80C Universal I/O chassis 1771-A1B, -A2B, -A3B, -A3B1, B - -A4B 1 DeviceNet Scanner module 1771-SDN/B B - 1 Ethernet Interface module (2) 1785-ENET DeviceNet Quad-Tap 1492-DN3TW RediSTATION operator interface module 2705-TxDN1x42x-xxxx Series 9000 Photoeye 42GNP-9000 or equivalent 1 DeviceNet RS-232 interface module 1770-KFD RS-232 cables 1787-RSCABL/A (PC to 1770-KFD) DeviceNet dropline or trunkline 1787-PCABL, -TCABL, -MCABL - - cables, as needed 1 24V Power Supply Regulated 24VDC, 8A PC IBM-compatible Windows 95/98, NT 4.0 Software RSLogix RL5300xxx RSNetWorx for DeviceNet 9357-DNETL RSLinx 9355-WABxxx The minimum requirement for the processor is that it support block transfer instructions. A ControlNet version of the Processor is required if interfacing the DeviceNet network and a ControlNet network (see chapters 5 and 6). Required if interfacing the DeviceNet network and an Ethernet network. See chapters 5 and 6. Allen-Bradley Replacements

8 P-4 About This User Manual Common Techniques Used in This Manual The following conventions are used throughout this manual: Bulleted lists provide information, not procedural steps. Numbered lists provide sequential steps. Information in bold contained within text identifies menu windows, or screen options, screen names and areas of the screen, such as dialog boxes, status bars, radio buttons and parameters. TIP This symbol identifies helpful tips. This is a definition box. When a word is bold within the text of a paragraph, a definition box will appear in the left margin to further define the text. A definition box defines terms that may be unfamiliar to you. Screen captures are pictures of the software s actual screens. The names of screen buttons and fields are often in bold in the text of a procedure. Pictures of keys represent the actual keys you press. More The MORE icon is placed beside any paragraph that references sources of additional information outside of this document.

9 About This User Manual P-5 Where to Find More Information More Refer to the following publications as needed for additional help when setting up and using your DeviceNet network: For information about See this publication Publication Number the 1771-SDN DeviceNet scanner 1771-SDN Scanner Module Installation Instructions the PLC-5 processor ControlNet PLC-5 Programmable Controllers User Manual Phase 1.5 PLC-5 Instruction Set Reference Manual PLC-5 Programmable Controllers Quick Reference the1785-enet Ethernet interface module PLC-5 Ethernet Interface Module User Manual the 1771 I/O chassis Universal I/O Chassis the 1770-KFD communication module DeviceNet RS-232 Interface Module Installation Instructions a 1784-PCD communication card NetLinx DeviceNet Communication Card Installation Instructions a 1784-PCID or 1784-PCIDS card DeviceNet PCI Communication Interface Card Installation the RediSTATION RediSTATION Operator Interface User Manual the 9000 Series photoeye {refer to the information that came with your photoeye} n/a DeviceNet DeviceNet System Overview DN-2.5 DeviceNet Design Manual (online) DNET-AT-001A-EN connecting the DeviceNet network DeviceNet Cable Planning and Installation Manual DN DeviceNet Cable Planning and Installation Release Note 1 DN RN1 RSLinx software RSLinx Lite User s Guide 9399-WAB32LUG RSLogix 5 software Getting Results With RSLogix RL53GR RSNetWorx for DeviceNet software DeviceNet Demo CD 9398-DNETDEMO terms and definitions Allen-Bradley Industrial Automation Glossary AG-7.1 TIP Many of the above are available online from the Automation Bookstore: TIP For more information about Rockwell Software products, visit the Rockwell Software internet site: Allen-Bradley Replacements

10 P-6 About This User Manual Terminology This term Means Bridge The scanner module s support of explicit message transfer. Change of State A type of I/O data communication. The scanner module can send and receive data with slave devices that have the change of state feature. Data is sent whenever a data change occurs. Data is updated at the rate of the heartbeat. Communication The 1771-SDN scanner module or the 1770-KFD module. Module Cyclic A type of I/O data communication. The scanner module can send and receive data with slave devices that have the cyclic feature. Data is only sent at a user-configurable rate. EDS Electronic Data Sheet. A vendor-supplied template that specifies how information is displayed as well as what is an appropriate entry (value). Explicit Messaging Heartbeat Rate Host Platform I/O Implicit Messaging Input Data MAC ID Network Node Offline Online Output Data PC Polled Record Rx Scanlist Scanner Slave Mode Strobed Tx A type of messaging used for lower priority tasks, such as configuration and data monitoring. Devices that are configured for change of state data can also send a heartbeat signal to indicate proper operation. The computer that hosts the 1771-SDN scanner module. An abbreviation for input and output. The type of messaging used for high priority I/O control data; e.g., change of state, cyclic, polled, or strobed. Data produced by a DeviceNet device and collected by the scanner module for a host platform to read. The network address of a DeviceNet node. The DeviceNet network or the RSNetWorx for DeviceNet software representation of the network. Hardware that is assigned a single address on the network (also referred to as device). When the PC communication scanner is not communicating on the network. When the PC communication scanner is configured and enabled to communicate on the network. Data produced by a host platform that is written to the scanner module s memory. This data is sent by the scanner module to DeviceNet devices. Abbreviation for an IBM compatible personal-computer. A type of input/output-data communication. A polled message solicits a response from a single, specified device on the network (a point-to-point transfer of data). The node address and channel-specific memory assigned in the scanner module s non-volatile storage for a node in the scanlist. An abbreviation for receive. The list of devices (nodes) with which the scanner is configured to exchange I/O data. The function of the 1771-SDN scanner module to support the exchange of I/O with slave modules. The scanner module is in slave mode when it is placed in another scanner module s scanlist as a slave device. A type of I/O data communication. A strobed message solicits a response from each strobed device (a multicast transfer). It is a 64-bit message that contains one bit for each device on the network. An abbreviation for transmit.

11 About This User Manual P-7 Rockwell Automation Support Rockwell Automation offers support services worldwide, with over 75 sales/support offices, 512 authorized distributors, and 260 authorized systems integrators located throughout the United States alone, plus Rockwell Automation representatives in every major country in the world. Local Product Support Contact your local Rockwell Automation representative for: sales and order support product technical training warranty support support service agreements Technical Product Assistance If you need to contact Rockwell Automation for technical assistance, call your local Rockwell Automation representative, or call Rockwell directly at: For presales support, call NET. You can obtain technical assistance online from the following Rockwell Automation WEB sites: (knowledge base) (electronic data sheets) Your Questions or Comments about This Manual If you find a problem with this manual, please notify us of it on the enclosed Publication Problem Report (at the back of this manual). If you have any suggestions about how we can make this manual more useful to you, please contact us at the following address: Rockwell Automation, Allen-Bradley Company, Inc. Control and Information Group Technical Communication 1 Allen-Bradley Drive Mayfield Heights, OH Allen-Bradley Replacements

12 P-8 About This User Manual

13 Table of Contents Chapter 1 Before You Begin What This Chapter Contains What You Need to Know What Your 1771-SDN Module Does Address Density and Discrete I/O Communicating with Your Devices Communicating with Your PLC-5 Processor What 1771-SDN Module Data Tables Are and What They Do The Scanner Configuration Table (SCT) The Scanlist Table (SLT) RSNetWorx Software as a Configuration Tool RSNetWorx for DeviceNet Configuration Screen Map What s Next? Planning Your Configuration and Data Mapping Your Devices Chapter 2 What You Need to Know Beginning the Process The Example Network Example Network Devices RediSTATION Operator Interface Data Mapping Mapping RediSTATION Input Data for a Block Transfer Read Mapping RediSTATION Output Data for a Block Transfer Write Photoeye Input Data Mapping Mapping Photoeye Input Data for a Block Transfer Read What s Next? Chapter 3 Hardware Setup What This Chapter Contains Installing the 1770-KFD Interface Module Installing the PLC-5 Processor Setting the I/O Chassis Backplane Switches Going Online to the PLC-5 Processor Installing the 1785-ENET Ethernet Module Installing the 1771-SDN Scanner Module Setting the Channel 1 Data Rate and Node Address Switches Setting the I/O Chassis Addressing Node Switches Installing the Scanner Module in the Chassis Connecting the Scanner to the DeviceNet Network Installing the RediSTATION Operator Interface Installing the Series 9000 Photoeye How Your Example System Will Look What s Next? Allen-Bradley Replacements i

14 Table of Contents ii Configuring the DeviceNet Network Communicating with DeviceNet from Another Network Creating and Running the Example Application Program Chapter 4 What This Chapter Contains Installing the Software Using RSLinx to Configure the DeviceNet Driver Using RSNetWorx for DeviceNet to Configure the Scanlist Setting Up an Online Connection Setting the 1771-SDN Node Address Configuring the I/O Devices Verifying the Photoeye Configuration Verifying the RediSTATION Configuration AutoMapping the Devices into the Scanlist Download the Configuration to the Scanner What s Next? Chapter 5 What This Chapter Contains Where to Find More Information Communicating with DeviceNet from a ControlNet Network Configuring the DeviceNet Pass-Through Driver Communicating with the DeviceNet Network Communicating with DeviceNet from an Ethernet Network Configuring the Ethernet to PLC-5 Communications Driver. 5-9 Configuring the DeviceNet Pass-Through Driver Communicating with the DeviceNet Network Communicating with DeviceNet from a DH+ Network Configuring the DeviceNet Pass-Through Driver Communicating with the DeviceNet Network What s Next? Chapter 6 What This Chapter Contains Installing the Software Creating the Example Application Program Downloading and Running the Program Downloading and Running the Program via a ControlNet Network Testing the Example Program Downloading and Running the Program via an Ethernet Network Testing the Example Program Downloading and Running the Program via a DH+ Network Testing the Example Program What s Next?

15 Table of Contents iii Chapter 7 Troubleshooting What This Chapter Contains Module Status Indicator Network Status Indicator Node/Error Code Indicator ENET Module Channel Configuration Installing and Configuring the ControlNet Communications Driver Installing and Configuring the DH+ Communications Driver Appendix A Configuring the Communications Channel A-1 Appendix B Installing the 1784-KTCX15 Communication Interface Card... B-1 Configuring the 1784-KTCX15 Communications Driver.... B-2 Appendix C Installing the 1784-KTX Communication Interface Card C-1 Configuring the 1784-KTX Communications Driver C-2 Appendix D Data Map Example Example Input Mapping Scheme D-1 Example Characteristics D-1 Example Framework D-2 Input Data Table Formats D-3 Example Output Mapping Scheme D-6 Example Characteristics D-6 Example Framework D-6 Output Data Table Formats D-7 Index Allen-Bradley Replacements

16 Table of Contents iv

17 Chapter 1 Before You Begin What This Chapter Contains This chapter provides an overview of communication between a PLC-5 processor and DeviceNet devices via a 1771-SDN module. The data tables and the RSNetWorx for DeviceNet screens and windows used to configure the data tables are also described. The following table identifies what this chapter contains and where to find specific information. For information about See page What You Need to Know 1-1 What Your 1771-SDN Module Does 1-2 Communicating with Your Devices 1-6 What 1771-SDN Module Data Tables Are and What They Do 1-8 The Scanner Configuration Table (SCT) 1-8 The Scanlist Table (SLT) 1-8 RSNetWorx Software as a Configuration Tool 1-9 RSNetWorx for DeviceNet Configuration Screen Map 1-10 What You Need to Know Before configuring your 1771-SDN scanner module, you must understand: the data exchange between the PLC -5 processor and DeviceNet devices through the 1771-SDN module user-configurable 1771-SDN module data tables the role of RSNetWorx for DeviceNet software Allen-Bradley Replacements 1

18 1-2 Before You Begin What Your 1771-SDN Module Does In a typical configuration, the 1771-SDN module acts as an interface between DeviceNet devices and the PLC-5 processor SDN Scanner module DeviceNet Network PC with RSNetWorx for DeviceNet software 1771 I/O Chassis PLC-5 Processor 1770-KFD PC Communication Module Series 9000 Photoeye RediSTATION FLEX I/O Rack DeviceNet Devices 1305 Drive The 1771-SDN module communicates with DeviceNet devices over the network to: read inputs from a device write outputs to a device download configuration data monitor a device s operational status The 1771-SDN module communicates with the processor in the form of Block Transfers (BT) and/or Discrete I/O (DIO). Information exchanged includes: device I/O data status information configuration data

19 Before You Begin 1-3 A processor to I/O DeviceNet configuration is shown in the following figure. See the referenced chapters for more information. Input Read by Processor (Chapter 2) Processor to I/O Configure SDN module (Chapter 4) Mapping Table (Chapters 2 and 4) PC running RSNetWorx for DeviceNet Output Write by Processor (Chapter 2) Output Data to Devices from SDN (Chapter 2) Input Data from Device to SDN (Chapter 2) DeviceNet Network Input Device Output Device Allen-Bradley Replacements

20 1-4 Before You Begin The 1771-SDN scanner module can also be used to bridge a DeviceNet network with another network. Configuring Devices and Data Collection on Higher-Level Networks Via PLC-5/SDN Industrial workstation running RSView Laptop PC running RSNetWorx ControlNet, DH+, or Ethernet Network Configuration of device using RSNetWorx (Chapters 4 & 5) SDN scanner module DeviceNet Network Collection of status or alarm data (Chapter 6) Target Device to be configured Source Device to collect data Address Density and Discrete I/O You can use three addressing methods with your 1771-SDN scanner module. The number of discrete I/O bits you have available for data transfer is affected by the addressing mode selected. Addressing Mode Discrete Inputs Discrete Outputs 2-slot 0 bits 0 bits 1-slot 8 bits 8 bits 1/2-slot 24 bits 24 bits

21 Before You Begin 1-5 The concept described below applies to both input and output data tables. For example, when using your 1771-SDN in 1-slot addressing mode, you have eight bits of discrete input and eight bits of output available. = bits reserved for 1771-SDN and processor communication = bits available for discrete data transfer In the scanner s input and output data tables, there is one byte of memory that is reserved for communication between the processor and the scanner. Processor-specific responses from the scanner are read by the processor in this byte of the input data table. Scanner-specific instructions are written to this byte of the output data table. 0 bits for discrete data transfer 2-slot addressing In 2-slot addressing mode, the only memory that would have been available for discrete data transfer (8 bits) is taken up by scanner/processor communication. 8 bits for discrete data transfer 1-slot addressing In 1-slot addressing mode, there are 16 bits: eight bits for scanner/processor communication, and eight bits for discrete data transfer. 24 bits for discrete data transfer 1/2-slot addressing In 1/2-slot addressing mode, there are 32 bits: eight bits used for scanner/processor communication, and 24 bits for discrete data transfer. More The address density is set via dip switches on the 1771-SDN module and 1771 chassis. For more information about setting your module s address density with switches, refer to the 1771-SDN Scanner Module Installation Instructions, publication For more information about 1771-module addressing, refer to chapter 3 and to your PLC programmable controller system-level installation manual and design manual. Allen-Bradley Replacements

22 1-6 Before You Begin Communicating with Your Devices A strobe message is a multicast transfer of data (which is 64 bits in length) sent by the 1771-SDN module that solicits a response from each strobed slave device. There is one bit for each of the possible 64 node addresses. The devices respond with their data, which can be as much as 8 bytes. A poll message is a point-to-point transfer of data (0-255 bytes) sent by the 1771-SDN module that solicits a response from a single device. The device responds with its input data (0-255 bytes). A change of state message is a transfer of data sent whenever a data change occurs. A user-configurable heartbeat rate can also be set to allow devices to indicate proper operation during intervals between data changes. This does not solicit response data, but may receive an acknowledge message. A cyclic message is sent only at a user-configurable rate, such as every 10 ms. The 1771-SDN module communicates with a device via strobe, poll, change of state, and/or cyclic messages. It uses these messages to solicit data from or deliver data to each device. Data received from the devices, or input data, is organized by the 1771-SDN module and made available to the processor. Data received from your PLC-5 processor, or output data, is organized in the 1771-SDN module and sent on to your devices. IMPORTANT Data from a single device can be mapped to separate 1771-SDN module memory locations. For example, On/Off values can be mapped to one location, diagnostic values to another, etc. This is known as map segmenting. This concept is illustrated by byte A, stored separately, as segments A1 and A2. Throughout this document, input and output are defined from the PLC-5 processor s point of view. Output is data sent from the PLC-5 processor to a device. Input is data collected by the PLC-5 processor from a device. All data sent and received on a DeviceNet network is in byte lengths. A device may, for example, produce only two bits of input information. Nevertheless, since the minimum data size on a DeviceNet network is one byte, two bits of information are included in the byte of data produced by the device. In this example (only two bits of input information), the upper six bits are insignificant SDN Scanner Module Input Data Storage A1 B C A2 D E E Byte input from the devices to the PLC-5 processor DeviceNet Devices A1 Input Data From DeviceNet Devices A2 B D E C Output Data Storage X Y Y Y Y Z output from the PLC-5 processor Output Data To DeviceNet Devices Y X Y Y Z

23 Before You Begin 1-7 Communicating with Your PLC-5 Processor A block transfer read (BTR) is a block transfer of data from the 1771-SDN module to the PLC processor. The processor is reading the data collected by the 1771-SDN module (i.e., DeviceNet input data). A block transfer write (BTW) is a block transfer of data from the PLC processor to the 1771-SDN module. The processor is writing the data to the 1771-SDN s memory (i.e., DeviceNet output data). Your processor communicates with the 1771-SDN scanner module via block transfer reads, block transfer writes, and DIO transfers. Input data, gathered from the network s devices, is organized within the 1771-SDN and made available for the processor to read. The 1771-SDN module does not send data to your processor. Data transferred between the module and the processor must be initiated by the processor. Output data is sent, or written, to the scanner by your processor. This data is organized in the 1771-SDN module, which in turn passes the data on to your scanned devices via strobe, poll, change of state, or cyclic messages. PLC-5 Processor Discrete Input Image B A1 Block Transfer Data File C A2 D E E I/O Map Discrete I/O Transfer Block Transfer Read 1771-SDN Scanner Internal Input Data Storage A1 B C A2 D E E Input from the devices Discrete Output Image X Block Transfer Data File Z Y Y Y Y Discrete I/O Transfer I/O Map Block Transfer Write Internal Output Data X Y Y Y Y Z Output to the devices Allen-Bradley Replacements

24 1-8 Before You Begin What 1771-SDN Module Data Tables Are and What They Do To manage the flow of data between your processor and the network devices, the 1771-SDN module uses the following data tables SDN Module Configuration Table Scanlist Table Device Input Data Table Device Output Data Table Device Idle Table Device Failure Table You can configure two of these data tables through RSNetWorx software. These two tables are stored in the 1771-SDN module s non-volatile memory and used to construct all other data tables: Scanner Configuration Table (SCT) Scanlist Table (SLT) The Scanner Configuration Table (SCT) The SCT controls basic information your 1771-SDN module needs to function on your DeviceNet network. It tells your 1771-SDN module: if it can transmit and receive input and output data how long it waits after each scan before it scans the devices again when to send out its poll messages The Scanlist Table (SLT) The SLT supports I/O updating for each of your devices on the network. It also makes it possible for your 1771-SDN module to make device data available to your processor. The SLT tells your 1771-SDN module: which device node addresses to scan how to scan each device (strobe, poll, change of state, cyclic or any valid combination) how often to scan your devices

25 Before You Begin 1-9 exactly where in each device s total data to find the desired data the size of the input data/output data exactly where to map the input or output data for your processor to read or write Interscan delay is the time between I/O scans (polled and strobed). It is the time the 1771-SDN module will wait between the last poll message request and the start of the next scan cycle. Background poll ratio sets the frequency of poll messages to a device in relation to the number of I/O scans. For example, if the ratio is set at 10, that device will be polled once every 10 scans. User Data In This Table Configured Tables SCT basic operation module parameters interscan delay background poll ratio SLT device-specific identification data data transfer method transmit/receive data size input and output data source and destination locations RSNetWorx Configuration Screen 1771-SDN Module Configuration Scanlist Editor (SLE) Edit Device I/O Parameters These values can be configured automatically through the AutoMap function or manually through the Data Table Map. RSNetWorx Software as a Configuration Tool RSNetWorx for DeviceNet software is used to configure the 1771-SDN module s data tables. This software tool connects to the 1771-SDN module over the DeviceNet network via a PC RS 232 interface (1770 KFD module), or PC Card (1784-PCD, -PCID, or PCIDS). TIP RSNetWorx for DeviceNet software can also communicate with the 1771-SDN module via a ControlNet, Ethernet, or Data Highway Plus network. See chapter 5. Allen-Bradley Replacements

26 1-10 Before You Begin The configuration screen map below shows the RSNetWorx for DeviceNet screens used to configure the 1771-SDN module and the navigation paths between them. The use of these screens is described in Chapter 4. RSNetWorx for DeviceNet Configuration Screen Map The main RSNetWorx for DeviceNet screen. To browse the network, click on the Online button and select the driver. To access the 1771-SDN scanner Module, double-click on the 1771-SDN icon. To access the scanlist, click on the Scanlist tab. To download the scanlist, click on the Download to Scanner button. To automatically map input devices, select the Input tab and click on the AutoMap button. To automatically map output devices, select the Output tab and click on the AutoMap button. To edit a device s I/O parameters, double-click on the device in the scanlist.

27 Before You Begin 1-11 What s Next? The remaining sections of this manual provide the following information: Chapter 2 covers the configuration process planning stage through a data mapping example. Chapter 3 describes the hardware setup for the example application. Chapter 4 covers configuration of the DeviceNet network using RSNetWorx for DeviceNet software. Chapter 5 describes how to communicate with a DeviceNet network from another network. Chapter 6 describes how to create, download, and run the example application program. Chapter 7 covers the diagnostics provided for troubleshooting the 1771-SDN module. Allen-Bradley Replacements

28 1-12 Before You Begin

29 Chapter 2 Planning Your Configuration and Data Mapping Your Devices This chapter introduces questions you should ask before configuring your 1771-SDN Scanner. In addition, it presents an example DeviceNet network and I/O data mapping scheme for a photoeye and a RediSTATION operator interface module. The following table identifies what this chapter covers and where to find specific information. For information about See page What You Need to Know 2-1 Beginning the Process 2-1 The Example Network 2-2 Example Network Devices 2-2 Photoeye Input Data Mapping 2-7 Mapping Photoeye Input Data for a Block Transfer Read 2-8 RediSTATION Operator Interface Data Mapping 2-4 Mapping RediSTATION Input Data for a Block Transfer Read 2-5 Mapping RediSTATION Output Data for a Block Transfer Write 2-6 What You Need to Know To map data via your 1771-SDN Scanner module, you must understand: your network requirements how input data is mapped how output data is mapped Beginning the Process Planning before configuring your 1771-SDN module helps make sure that you can: use your memory and bandwidth efficiently cater to device-specific needs and requirements give priority to critical I/O transfers leave room for expansion Allen-Bradley Replacements 1

30 2-2 Planning Your Configuration and Data Mapping Your Devices A very important question to answer is what is on your network? You should be familiar with each device s: communication requirements I/O importance and size frequency of message delivery You should also ask how might this network appear in the future? At this point in your planning, it is advantageous for you to have some idea of how the network could be expanded. I/O data mapping can be performed automatically by the RSNetWorx software. But when mapping your I/O, you also have the opportunity to allot room for future I/O. This can save time and effort in the future. For example, RSNetWorx will automatically map the devices as efficiently as possible, but the result is that multiple devices may share the same word location in memory. However, you can also have the system map the devices such that no two devices share the same memory location by selecting the Dword align option when performing automapping. You can manually map the devices if you need to assign them to specific memory locations. For details refer to the Help screens provided by the RSNetWorx for DeviceNet software. Additional support can be found at the Rockwell Software website: The Example Network The following example illustrates a data mapping plan for a DeviceNet network. Note that even if the mapping is performed automatically by the RSNetWorx software, you must know where the devices are mapped in order to use them in your network. Example Network Devices This example network has the following devices: a PC running RSNetWorx for DeviceNet software a 1771-SDN Scanner module interfacing a PLC-5 processor with DeviceNet a Series 9000 photoelectric sensor (strobed) a RediSTATION operator interface (polled)

31 Planning Your Configuration and Data Mapping Your Devices 2-3 IMPORTANT In the following example, output is data sent to a device from a controller. Input is data collected from a device by a controller. The system you will set up is shown below: PC running Windows NT or Windows 95/98, containing RSNetWorx for DeviceNet software Node KFD Communication Module Node 9 Series 9000 Photoelectric Sensor DeviceNet Network Node 0 Node SDN and PLC-5 in 1771 I/O Chassis * See note below RediSTATION Operator Interface IMPORTANT Each end of the DeviceNet trunk cable must be properly terminated with a resistor. Refer to the DeviceNet Cable Planning and Installation Manual, publication DN for detailed information. Allen-Bradley Replacements

32 2-4 Planning Your Configuration and Data Mapping Your Devices RediSTATION Operator Interface Data Mapping The RediSTATION has both inputs and outputs that must be mapped. The input byte is mapped to the 1771-SDN module s block transfer read data table and then to the PLC-5 processor s input data file. The output byte is mapped to the 1771-SDN module s block transfer write data table and then to the PLC-5 processor s output data file. The mapping procedure, using RSNetWorx for DeviceNet software, is described on pages 4-14 to RediSTATION operator interface Indicator light green start light red start light Two input bits from the RediSTATION will be mapped: bit 1 for the green Start button and bit 0 for the red Stop button. Bit 4 of the input byte indicates if the bulb is missing. start bit (green button) The RediSTATION operator interface produces one byte of input data and uses one byte of output data. input output 1 byte G R byte L stop bit (red button) status bit for indicator light One output bit for the RediSTATION s indicator light (on/off) will be mapped. In the RediSTATION s bits for the red and green buttons and the indicator light status bit: 1 = ON 0 = OFF

33 Planning Your Configuration and Data Mapping Your Devices 2-5 Mapping RediSTATION Input Data for a Block Transfer Read The RediSTATION operator interface s input byte is mapped to the scanner s block transfer read data table through a 62 word BTR. In this example, we use data file N9: What s Happening? The bits for the RediSTATION operator interfaces s red and green buttons are mapped into the 1771-SDN Scanner s BTR data table. The BTR data table is then transferred via a BTR to the PLC-5 processor s input data file. Important: The 1771-SDN module only makes the data file available for the processor to read. The 1771-SDN does not move the data file to the processor. Note: This example uses 1-slot addressing. RediSTATION Input Byte 1 byte G R 1 R = bit for red button (STOP) G = bit for green button (START) = unused bits 1771-SDN Scanner Block Transfer Read Data Table reserved for module status word = bits reserved for module status word Word 0 PLC-5 Processor Input Data File 1 N9: G R Word 1 Word 2 N9: GR N9: Word 3 N9: N9: Word 4 N9: N9: Word 61 1 This mapping is based upon the example in chapter 4. The mapping for your system may be different. Example: The green START button from the RediSTATION appears in the PLC-5 processor s input file at address N9:1/1. The red STOP button from the RediSTATION appears in the PLC-5 processor s input file at address N9:1/0. Allen-Bradley Replacements

34 2-6 Planning Your Configuration and Data Mapping Your Devices Mapping RediSTATION Output Data for a Block Transfer Write The RediSTATION operator interface s output byte is mapped to the 1771-SDN module s block transfer write data table. Within the output byte is bit 0 for the indicator light. The PLC-5 s output data file is transferred by the processor application to turn the light on or off. In this example, we use N10 for the output data file. What s Happening? RediSTATION Output 1 The PLC-5 processor s output data file containing the indicator light bit for the RediSTATION is transferred via a BTW to the 1771-SDN Scanner s BTW data table. start/stop station node address 7 1 byte L 2 L = bit for the station indicator light = unused bits 2 The BTW data table is then sent to the RediSTATION via a polled message from which the RediSTATION receives its indicator light bit. Note: This example uses 1-slot addressing. = bits reserved for module status word 1771-SDN Scanner Block Transfer Write Data Table PLC-5 Processor Output Data File 1 N10: reserved for module status word L Word 0 Word 1 N10: L N10: N10: Word 2 Word 3 N10: N10: Word 4 N10: This mapping is based upon the example in chapter 4. The actual mapping for your system may be different. Example: The RediSTATION s indicator light (L) is taken from N10:1/0 in the PLC-5 processor s output data file. Word 61

35 Planning Your Configuration and Data Mapping Your Devices 2-7 Photoeye Input Data Mapping The photoelectric sensor (photoeye) inputs are mapped to the 1771-SDN module s block transfer read data table and then to the PLC-5 processor s input data file. The procedure for doing this using RSNetWorx for DeviceNet software is described on pages 4-14 to The photoeye has no outputs to map. Series 9000 Photoeye Two input bits from the photoeye will be mapped: the status bit and the data bit. The photoeye produces one byte of input data in response to the strobe message. status bit input 1 byte S D data bit Allen-Bradley Replacements

36 2-8 Planning Your Configuration and Data Mapping Your Devices Mapping Photoeye Input Data for a Block Transfer Read The photoeye s input byte is mapped to the scanner s block transfer read data table through a 62 word BTR. In this example, we use data file N9. What s Happening? 1 The status and data bits from the photoeye are mapped into the 1771-SDN Scanner s BTR data table. 2 The BTR data table is then transferred via a BTR to the PLC-5 processor s input data file. Important: The 1771-SDN module only makes the data available for the processor to read. The 1771-SDN module does not move the data to the processor. PLC-5 Processor Input Data File 1 N9: N9: SD N9: N9: N9: N9: Note: This example uses 1-slot addressing. 2 Photoeye Input Byte 1 byte 1 S D = unused bits 1771-SDN Scanner Block Transfer Read Data Table reserved for module status word S D = bits reserved for module status word RediSTATION Word 0 Word 1 Word 2 Word 3 Word 4 Word 61 N9: This mapping is based upon the example in chapter 4. The actual mapping for your system may be different. Example: The Status bit from the photoeye appears in the PLC-5 processor s integer file at address N9:1/9. The Data bit from the photoeye appears in the PLC-5 processor s integer file at address N9:1/8.

37 Planning Your Configuration and Data Mapping Your Devices 2-9 What s Next? Chapter 3 describes how to set up the system hardware for the example application. Allen-Bradley Replacements

38 2-10 Planning Your Configuration and Data Mapping Your Devices

39 Chapter 3 Hardware Setup What This Chapter Contains This chapter describes how to set up the hardware for the example application. The following table describes what this chapter contains and where to find specific information. For information about See page Installing the 1770-KFD Interface Module 3-1 Installing the PLC-5 Processor 3-2 Setting the I/O Chassis Backplane Switches 3-2 Going Online to the PLC-5 Processor 3-3 Installing the 1785-ENET Ethernet Module 3-5 Installing the 1771-SDN Scanner Module 3-7 Setting the Channel 1 Data Rate and Node Address Switches 3-8 Setting the I/O Chassis Addressing Node Switches 3-8 Installing the Scanner Module in the Chassis 3-9 Connecting the Scanner to the DeviceNet Network 3-10 Installing the RediSTATION Operator Interface 3-11 Installing the Series 9000 Photoeye 3-12 How Your Example System Will Look 3-13 Installing the 1770-KFD Interface Module Connect the RS-232 connector on the 1770-KFD interface module to one of the serial ports on your PC workstation (e.g., COM1). Connect the DeviceNet connector on the 1770-KFD module to a DeviceNet drop or trunk cable. You can make this connection in several ways; for example, using a DeviceNet Quad Tap (#1492-DN3TW), as shown on page to PC COM KFD RS-232 Interface Module DeviceNet Dropline or Trunk Cable More For detailed directions on how to install the 1770-KFD interface module, see the DeviceNet RS-232 Interface Module Installation Instructions, publication Allen-Bradley Replacements 1

40 3-2 Hardware Setup Installing the PLC-5 Processor Refer to the following figure while installing your PLC-5 processor. PLC-5C Processor and 1771 I/O Chassis Locking Bar ControlNet Node Address Switches Lift Ejector Tab PLC-5/40C Processor Battery Connector Card Guides DH+ Address Switches (on back) Battery Battery Cover Setting the I/O Chassis Backplane Switches O FF O N Set the backplane switches in the 1771 I/O chassis for 1-slot addressing for the example application. To do this, put switch 4 in the OFF position and switch 5 in the ON position. Switches Addressing 4 5 OFF OFF 2 - slot OFF ON 1 - slot ON OFF 1/2 - slot ON ON Not Allowed ON OFF More For information on setting the other backplane switches for your system, refer to the ControlNet PLC-5 Programmable Controllers User Manual Phase 1.5, publication I/O Chassis

41 Hardware Setup 3-3 Going Online to the PLC-5 Processor You cannot go online to the PLC-5 processor over DeviceNet. In order to download and run the example application program in chapter 6 you must use the processor s RS-232 connector, or download and run the program via another network. Chapter 6 provides examples of downloading and running the application program via ControlNet, Ethernet, and Data Highway Plus networks. Chapter 5 provides examples of configuring the DeviceNet network over these networks. To go online to the PLC-5 processor via ControlNet: 1. Set the PLC-5C ControlNet node address using the two 10-digit rotary switches on top of the PLC-5C module. For the example application we used node address 16. ControlNet PLC-5C processor s NET address = Connect the PLC-5C s ControlNet port to the ControlNet network. More See Appendix B for information on installing and configuring the ControlNet driver. See the ControlNet 1.5 PLC-5 Programmable Controller User Manual, publication , for further information. Allen-Bradley Replacements

42 3-4 Hardware Setup To go online to the PLC-5 processor via Data Highway Plus: 1. Define the DH+ station address of channel 1A by setting switch assembly SW-1 on the back of the processor. For the example application we used address 1. (Set switch 4 in the up position, and switches 1, 2, 3, 5, and 6 in the down position.) TIP See the information on the side of the processor if you want to use another address. back view of processor Switch 4 in the up position side view down up Switch 7 in the up position. 2. Set the baud rate to 57.6 Kbaud by placing switch 7 in the up position. More See Appendix C for information on installing and configuring the Data Highway Plus driver.

43 Hardware Setup 3-5 Installing the 1785-ENET Ethernet Module To go online to the PLC-5 processor via Ethernet, you must install a 1785-ENET module in the 1771 I/O chassis. The Ethernet module is shipped with a 58-pin connector header that attaches to the PLC-5 processor. 1. Attach the connector header to the PLC-5 processor. Status Indicator Transmit Indicator Attach the interface module to this end. Connector Header Push the exposed pins into the holes on the PLC-5 processor. External Transceiver Fuse IMPORTANT Make sure you carefully align the pins and holes before you press the connector header into the processor. If you improperly align them, you will bend the connector header pins when you press them together. Do not use excessive force on the connector header when seating it into the processor. You do not need to key the connector. Channel 3A: 15-pin AUI Connector Port 2. Use the captive screws to connect the interface module to the processor. Allen-Bradley Replacements

44 3-6 Hardware Setup 3. Insert the interface module/processor combination in the left-most slot of the 1771 I/O chassis.! Be sure power to the 1771 I/O chassis is OFF. 4. Assign an IP address to the interface module. 5. Configure channel 3A for Ethernet communication. You can configure the communication channel using BOOTP software or your PLC-5 programming software. See Appendix A for information on configuring the communication channel using RSLogix 5 programming software. TIP Rockwell Automation offers a BOOTP tool on More For more information, see the PLC-5 Ethernet Interface Module User Manual, publication

45 Hardware Setup 3-7 Installing the 1771-SDN Scanner Module Refer to the following figure as you install the 1771-SDN module. Multi-position Switches - use to set the data rate, chassis addressing mode, and scanner node address for each channel. O N O N O N = ON = = OFF = 0 MODULE STATUS RESET Module Status Indicator - indicates whether the device has power and is functioning properly. Reset Button - resets your module. = ON = 1 CHANNEL 1 NETWORK STATUS NODE/ ERROR CODE DeviceNet Channel 1 Status Indicator - gives diagnostic indications for Channel 1. Node Address and Status Display - displays numeric codes that indicate scanner node address, status and/or errors for Channel 1. Data Rate Switch Settings = OFF = 0 Chassis Address Switch Settings DeviceNet Port 1 - use the color-coded header to wire your module. Channel 1 & 2 Node Address Switch Settings CHANNEL 2 NETWORK STATUS NODE/ ERROR CODE DeviceNet Channel 2 Status Indicator - gives diagnostic indications for Channel 2. Node Address and Status Display - displays numeric codes that indicate scanner node address, status and/or errors for Channel 2. DeviceNet Port 2 - use the color-coded header to wire your module. Left Side of Module Allen-Bradley 1771-SDN Allen-Bradley Replacements

46 3-8 Hardware Setup Setting the Channel 1 Data Rate and Node Address Switches O N Channel = ON = 1 = OFF = 0 1. Locate the switchbank labeled Channel 1 on the left side of the module. 2. Set the DeviceNet Data Rate for Channel 1 to 500K baud for the example application by setting switch 1 to an ON ( 1 ) position and switch 2 to an OFF ( 0 ) position. 3. Set the DeviceNet node address for Channel 1 to node 0 for the example application by setting switches 3 through 8 to the OFF ( 0 ) position. TIP Refer to the table on the left side of the module to set the channel to a different node address. The address range is 0 to 63. IMPORTANT The node address setting must not conflict with the node address of any other device on the network. Note that channel 2 is not used for the example application. Setting the I/O Chassis Addressing Node Switches O N Configuration = ON = 1 = OFF = 0 Set the I/O chassis addressing mode to 1-slot for the example application. 1. Locate the switchbank labeled Configuration on the left side of the module. 2. Set switch 7 to an OFF ( 0 ) position and switch 8 to an ON ( 1 ) position. IMPORTANT Make sure switches 1 through 6 in the Configuration switchbank always remain in the OFF ( 0 ) position. IMPORTANT The chassis addressing mode setting for the 1771 I/O chassis (page 3-2) must match the I/O chassis address setting of the scanner. If the switches do not match, data will be lost in the data transfer between the PLC-5 processor and the scanner module.

47 Hardware Setup 3-9 Installing the Scanner Module in the Chassis ATTENTION! Do not install the 1771-SDN Scanner Module with the chassis power supply on. Turn off the chassis power supply. You will disrupt backplane communication and may damage your module. 1. Select a slot for the 1771-SDN module in the chassis. You may use any slot except the leftmost slot, which is reserved for the PLC-5 processor. For the example application, we installed the scanner in slot Insert the 1771-SDN Scanner module into the slot. Apply firm, even pressure to seat the module in the I/O chassis backplane connectors. Allen-Bradley Replacements

48 3-10 Hardware Setup Connecting the Scanner to the DeviceNet Network ATTENTION! Do not wire your module with power applied to your network. You may short circuit your network or disrupt communication. To connect to the DeviceNet network: 1. Connect the DeviceNet drop line to the linear plug provided with the scanner. Match the wire insulation colors to the colors shown on the label. Module label shows wiring color scheme MODULE STATUS RESET Front of Scanner Module CHANNEL 1 NETWORK STATUS NODE/ ERROR CODE DeviceNet CHANNEL 2 NETWORK STATUS NODE/ ERROR CODE DeviceNet RED WHITE BARE BLUE BLACK 2. Locate the DeviceNet port connector for Channel 1 on the front of the module. 3. Insert the linear plug into the five-pin header for Channel 1. Channel 1 Port Connector Dedicated DeviceNet Drop Line

49 Hardware Setup 3-11 Installing the RediSTATION Operator Interface Begin installing the RediSTATION by removing the six screws fastening the cover and setting the DIP switches inside as follows: Set this position To this value: 1 On 1 On 1 On (node 0 Off address 1 ) 0 Off 0 Off 0 Off (data 1 On rate 2 ) 0 Off 0 Off 1 The DeviceNet address is (node 7). 2 The data rate is 10 (500k bps). The output fault rate is 0 (outputs turned off). The output flash rate is 0 (outputs tuned off). More See Chapter 2 of the RediSTATION Operator Interface User Manual, publication , for complete information about setting the DIP switches to configure the node address, data rate, output flash rate, and output fault state. Refer to the following illustration as you connect the RediSTATION to the network. TIP You do not need to disconnect incoming power from the DeviceNet network before connecting the RediSTATION. DeviceNet Cable The DeviceNet cable connects directly to the mini connector on the top of the RediSTATION enclosure or through the conduit opening (open style). mini connector open style Allen-Bradley Replacements

50 3-12 Hardware Setup Installing the Series 9000 Photoeye Connect the photoeye to the network and configure the photoeye as follows: Node Address: 9 Operating Mode: Light Operate (default) Baud Rate: 500 kb Top View of Series 9000 Photoeye Programming Pushbutton Sensitivity Adjustment Yellow - Output Green - Margin Red/Green - Status More For detailed directions, see the instructions that came with your photoeye.

51 Hardware Setup 3-13 How Your Example System Will Look When you have finished installing all the devices, your example system should look similar to the one shown below: PC running Windows NT or Windows 95/98, containing RSNetWorx for DeviceNet software PC Serial Port 1770-KFD Communication Module Node 62 Series 9000 Photoelectric Sensor 24V Node DN3TW Quad Tap Node 0 Node 7 PLC-5 Processor with 1771-SDN module in 1771 I/O chassis RediSTATION Operator Interface IMPORTANT Make sure each end of your DeviceNet trunk cable is properly terminated with a resistor. Refer to the DeviceNet Cable Planning and Installation Manual, publication DN for detailed information. What s Next? The next step is to configure the 1771-SDN module and perform I/O data mapping using RSNetWorx for DeviceNet software. Allen-Bradley Replacements

52 3-14 Hardware Setup

53 Chapter 4 Configuring the DeviceNet Network What This Chapter Contains This chapter describes how to configure the DeviceNet network using RSLinx and RSNetWorx for DeviceNet software. The following table describes what this chapter contains and where to find specific information. For information about See page Installing the Software 4-1 Using RSLinx to Configure the DeviceNet Driver 4-2 Using RSNetWorx for DeviceNet to Configure the Scanlist 4-4 Setting Up an Online Connection 4-4 Setting the 1771-SDN Node Address 4-6 Configuring the I/O Devices 4-9 Verifying the Photoeye Configuration 4-12 Verifying the RediSTATION Configuration 4-13 AutoMapping the Devices into the Scanlist 4-14 Installing the Software Install the RSLinx and RSNetWorx software. 1. Insert the CD in the CD-ROM drive. Note: The CD-ROM supports Windows Autorun. Once inserted into the CD-ROM drive, if you have Autorun configured, the installation will automatically start at the first setup screen. If Autorun is not configured for your CD-ROM drive, go to step From the Start menu, choose Run. You will see the Run pop-up window. 3. Type d:/setup (if it doesn t appear automatically), where d: is your CD-ROM driver letter. 4. Click on OK. You see the progress bar, followed by the welcome screen. Allen-Bradley Replacements 1

54 4-2 Configuring the DeviceNet Network Using RSLinx to Configure the DeviceNet Driver After you install the software, you use RSLinx to configure your DeviceNet driver and RSNetWorx for DeviceNet to configure the network. 1. Start the RSLinx software. 2. From the Communications menu, select Configure Drivers. The Configure Drivers window will appear. 3. From the list of Available Drivers, select DeviceNet Drivers and click on Add/New. You will see the following list of drivers: 4. Select the Allen-Bradley 1770-KFD driver.

55 Configuring the DeviceNet Network 4-3 The Allen-Bradley 1770-KFD Driver Configuration window will appear. Your driver setup will vary according to your system setup (COM port, Data Rate, Node Address). Choose the appropriate settings for your system. We set the DeviceNet Port Setup Data Rate to 500K for the example application. 5. Configure the driver using the example above as a guide and click on OK. The software will take a few seconds to configure the driver. When it is done the following prompt will appear: 6. Select the default driver name 1770-KFD-1 and click on OK. 7. Close RSLinx. You will use the driver you just configured to browse and configure the network with RSNetWorx for DeviceNet. Allen-Bradley Replacements

56 4-4 Configuring the DeviceNet Network Using RSNetWorx for DeviceNet to Configure the Scanlist Setting Up an Online Connection Follow the procedure below to set up an online connection to the DeviceNet network using the 1770-KFD driver. 1. Start RSNetWorx. 2. From the File menu, select New. If you have RSNetWorx for ControlNet installed on your computer you may see the following window. Otherwise, proceed to step Highlight DeviceNet Configuration and click on OK. 4. Click on the Online button on the toolbar.

57 Configuring the DeviceNet Network 4-5 The Browse for network window will appear. You will see the drivers you have configured on your system. 5. Select the 1770-KFD-1, DeviceNet driver and click on OK. You will be prompted to upload or download devices before going online. 6. Click on OK to go online and upload the network. RSNetWorx for DeviceNet will begin browsing for network devices. When the software is finished browsing, the network displayed on your screen should look similar to the one shown below. Allen-Bradley Replacements

58 4-6 Configuring the DeviceNet Network TIP RSNetWorx for DeviceNet performs a one-shot browse when you go online or choose the browse feature. The software will poll for devices once and display the results. If a node which was online later goes offline, there will be no live indication in RSNetWorx. You must manually perform a browse to detect the missing node. To perform the browse, press the button. Setting the 1771-SDN Node Address Once the devices are uploaded, their node addresses appear to the right of their icons. For the example application, the 1771-SDN scanner module should have a node address of 0 (or 00 ). If you need to change a module s node address, use the following procedure. TIP You can use this procedure to change the node address of other devices on the network (e.g., the Photoeye). You can also change the network data rate (baud rate) of some devices. Power must be cycled for baud rate changes to take effect. If 00 appears to the right of the 1771-SDN icon and you do not need to change the node address or baud rate of any device, skip the remainder of this section and go to Configuring the I/O Devices on page 4-9. IMPORTANT The network must not be active when performing node commissioning on the 1771-SDN module. Make sure the processor is in Program mode. (Note that this applies only to the 1771-SDN. You may commission other devices with the processor in Run mode.)

59 Configuring the DeviceNet Network 4-7 To change the node address of a device perform the following steps: 1. From the Tools menu select Node Commissioning. 2. Click on the Browse button. You will see the Device Selection window. 3. Select the 1770-KFD-1 driver. Allen-Bradley Replacements

60 4-8 Configuring the DeviceNet Network The devices on the network will appear in the right panel. 4. Select the device from the right panel and click on OK. You will see the Node Commissioning window with the current settings for the device. Your window will look similar to the one shown below. 5. In the New Device Settings: Node Address box, enter the new node address (e.g., a 0 as shown above). 6. Click on Apply. 7. Click on Exit to close the window.

61 Configuring the DeviceNet Network 4-9 Configuring the I/O Devices Next you must add the RediSTATION and the photoeye to the 1771-SDN s scanlist, configure and/or verify their parameters, and map them to the PLC-5 processor s memory. 1. Double-click on the 1771-SDN module icon. The following window will appear: 2. Select the Module tab. Allen-Bradley Replacements

62 4-10 Configuring the DeviceNet Network You will be prompted to upload or download the configuration. 3. Click on Upload. After uploading the Module page will appear: 4. Make sure the 1771-SDN module s Rack and Group numbers are correct. We used Rack 0, Group 1 for the example application. TIP We used the Module Defaults for the other settings. For an explanation of the other settings (Import and Export, PLC Interface Address, etc.) click on the Help button. 5. Select the Scanlist tab.

63 Configuring the DeviceNet Network 4-11 The Scanlist page will appear with the RediSTATION and the photoeye in the list of Available Devices. 6. For this example, uncheck the Automap on Add box, as shown above. You will do this mapping later. 7. Click on the double arrow button to add the photoeye and RediSTATION to the Scanlist. The photoeye and the RediSTATION will appear in the Scanlist in the right panel. 8. Click on OK. Allen-Bradley Replacements

64 4-12 Configuring the DeviceNet Network You will be prompted to download the changes to the device (i.e., the scanner). 9. Click on Yes. IMPORTANT The PLC-5 processor must be in Program mode to download the scanlist to the 1771-SDN module. Verifying the Photoeye Configuration 1. Double-click on the 1771-SDN module icon and again select the Scanlist tab. 2. Double-click on the photoeye in the Scanlist.

65 Configuring the DeviceNet Network 4-13 The Edit I/O Parameters window will appear for the photoeye. The I/O parameters define the configuration for the device in terms of how much and what data the device will exchange with the 1771-SDN module. By default, the photoeye will send 1 byte when it receives a strobe request. Recall from chapter 3 that the output of the photoeye will be returned in bit 0 of that byte. 3. Verify that the photoeye parameters are set as shown above. Make any changes as necessary and click on OK. 4. Close the Edit I/O Parameters window for the photoeye. Verifying the RediSTATION Configuration 1. Double-click on the RediSTATION in the Scanlist window. The Edit I/O Parameters window will appear for the RediSTATION. 2. Make sure that the Polled box is checked and that the Rx Size and Tx Size are each 1 byte. Allen-Bradley Replacements

66 4-14 Configuring the DeviceNet Network 3. Click on OK if you made any changes and close the Edit I/O Parameters window for the RediSTATION. 4. Click on OK again. You will be prompted to download the changes to the 1771-SDN module. 5. Click on Yes to download the new configuration. AutoMapping the Devices into the Scanlist Follow the procedure below to automatically map the photoeye and RediSTATION to the PLC-5 processor. TIP If you want to know how to map the devices manually, click on the Help button at the bottom of the screen and select Map device input data manually. 1. Double-click on the 1771-SDN module icon and select the Input tab. You will see the following window. There are six available blocks. Block Xfer 62 is the default. 2. Highlight the RediSTATION and the photoeye as shown above and click on the AutoMap button.

67 Configuring the DeviceNet Network 4-15 The resulting device mapping will appear in the lower panel of the window: File N9, Word 1 Note: The source address is actually determined by the block transfer instruction in the ladder logic. See chapter 6. Photoeye inputs RediSTATION inputs In this example, the input byte from the RediSTATION will appear in the PLC-5 processor in file N9, word 1, as bits 0-7. Recall from chapter 2 that the START button is bit 1 and the STOP button is bit 0. Therefore, the addresses for the RediSTATION inputs are: START N9:1.1 STOP N9:1.0 The input byte from the photoeye will appear in the PLC-5 processor in file N9, word 1, as bits Recall from chapter 3 that the input bit is bit 0. Therefore, the address of the photoeye input bit is: N9: Note the addresses assigned to the START and STOP buttons and the photoeye in your system. You will enter these addresses in the example ladder program. Allen-Bradley Replacements

68 4-16 Configuring the DeviceNet Network 4. Select the Output tab. Highlight the RediSTATION as shown above and click on the AutoMap button. The mapping of the RediSTATION will appear in the lower panel. File N10, Word 1 Note: The destination address is actually determined by the block transfer instruction in the ladder logic. See chapter 6. After mapping the RediSTATION output address will appear here. In this example, the output to the RediSTATION appears in the PLC-5 processor in file N10, word 1, as the lower byte (bits 0-7). Recall from chapter 3 that the indicator light is output bit 0. Therefore, the address for the RediSTATION s indicator light is: N10: Note the address assigned to this output in your system. You will enter this address in the example ladder logic program.

69 Configuring the DeviceNet Network 4-17 Download the Configuration to the Scanner 1. Click on the Scanlist tab and then on the Download to Scanner button. You will see this window: 2. Select Channel A (default). Note: Both channels will download. 3. Select All Records. 4. Click on the Download button to download the configuration to the 1771-SDN scanner module. 5. Click on the OK button to complete the DeviceNet scanner configuration. 6. Select the Save as option from the File menu, and save the DeviceNet configuration, using an appropriate name, e.g., 1771-SDN.dnt. 7. Close the RSNetWorx for DeviceNet software. What s Next? The next chapter describes how to configure the DeviceNet network remotely from other networks: Ethernet, ControlNet, and Data Highway Plus. Allen-Bradley Replacements

70 4-18 Configuring the DeviceNet Network

71 Chapter 5 Communicating with DeviceNet from Another Network What This Chapter Contains This chapter describes how to communicate with the DeviceNet network from another network, using the PLC-5 pass-through feature. This feature can be used to adjust and fine tune the nodes on your network. Examples are provided for communicating from a ControlNet network, an Ethernet network, and a Data Highway Plus network. ATTENTION! The pass-through feature is not intended to replace a 1770-KFD, PCD, PCID, or PCIDS connection to the network: Pass-through is intended only for fine tuning and adjustment of your network devices. Do not attempt to configure your entire network using a pass-through driver, or a time-out may occur. The pass-through method is not suitable for real time monitoring of your network devices. IMPORTANT To use the pass-through feature you must have the following versions of the RSLinx software and 1771-SDN module firmware: Component RSLinx software 1771-SDN module Software/Firmware Version 2.10 or higher or higher You must have previously set up the network you will use to communicate with the DeviceNet network and have installed and configured the appropriate drivers and interface hardware. The 1771 I/O chassis used for these examples was set up with the following hardware mapping: Module Rack Group Slot IP Address PLC-5C/1785-ENET Allen-Bradley Replacements 1771-SDN n/a 1

72 5-2 Communicating with DeviceNet from Another Network The following table describes what this chapter contains and where to find specific information. For information about See page Where to Find More Information 5-2 Communicating with DeviceNet from a ControlNet Network 5-3 Communicating with DeviceNet from an Ethernet Network 5-9 Communicating with DeviceNet from a DH+ Network 5-18 Where to Find More Information More Refer to the following publications for information on configuring other networks: For information about: See this publication: Publication number: the ControlNet PLC-5 processor ControlNet PLC-5 Programmable Controllers User Manual the Ethernet interface module PLC-5 Ethernet Interface Module User Manual TCP/IP protocol and networking in general Comer, Douglas E., Internetworking with TCP-IP, Volume 1: n/a Protocols and Architecture, 2nd ed. Englewood Cliffs, N.J.:Prentice-Hall, ISBN Tannebaum, Andrew S. Computer Networks, 2nd ed. Englewood Cliffs, N.J.: Prentice-Hall, ISBN X. n/a

73 Communicating with DeviceNet from Another Network 5-3 Communicating with DeviceNet from a ControlNet Network Before performing this example the ControlNet network must be configured and running. A ControlNet processor (PLC-5C) is required. In this example the PLC-5C processor is configured as ControlNet node 16. Use your own ControlNet PLC-5C processor s configuration when performing this example. Configuring the DeviceNet Pass-Through Driver Before you can communicate with the 1771-SDN module via the ControlNet network, you must first configure the DeviceNet pass-through driver (1771-SDNPT) with a ControlNet port. RSLinx, version 2.10 or higher, is required. To configure the ControlNet pass-through driver perform the following steps: 1. Start RSLinx. 2. From the Communications menu, select Configure Drivers. 3. From the list of Available Driver Types select DeviceNet Drivers and click on Add/New. Allen-Bradley Replacements

74 5-4 Communicating with DeviceNet from Another Network You will see the following list of drivers. 4. Select the Allen-Bradley 1771-SDNPT driver. The Driver Configuration window will appear. 5. Select a pass-through port to be configured from the pull-down list, e.g., Port Expand your installed ControlNet driver (AB_KTC-1 in the example) and highlight your PLC-5C processor. 7. Select the 1771-SDN Backplane Address Configuration. We used the following configuration for the example application. Rack 0 Group 1 Slot 0 8. Select the DeviceNet Channel (Channel 1 for the example application).

75 Communicating with DeviceNet from Another Network Click on OK. You will see the following warning: 10. Verify that the routing information is accurate and click on the Yes button. You will be prompted to choose a name for the driver. 11. Enter an appropriate driver name (e.g., 1771-SDNPT-1) and click on the OK button. The new driver will be added to the Configured Drivers in RSLinx. (Your list will contain the drivers you have configured.) 12. Close or Minimize RSLinx. Allen-Bradley Replacements

76 5-6 Communicating with DeviceNet from Another Network Communicating with the DeviceNet Network Once you have the ControlNet pass-through driver configured, you can use RSNetWorx for DeviceNet to communicate with the DeviceNet network via the ControlNet network. Perform the following steps: 1. Start RSNetWorx. 2. From the File menu, select New. If you have RSNetWorx for ControlNet installed on your computer you may see the following window. Otherwise, proceed to step Select DeviceNet Configuration and click on OK. 4. Click on the Online button on the toolbar.

77 Communicating with DeviceNet from Another Network 5-7 The Browse for network window will appear. You will see the drivers you have configured on your system. 5. Highlight your DeviceNet pass-through driver (1771-SDNPT-1 above) and click on OK. You will receive the following prompt: 6. Click on OK to upload the devices. RSNetWorx for DeviceNet will begin browsing for network devices. ATTENTION! Performing a pass-through browse via the ControlNet network will take longer than browsing using the 1770-KFD DeviceNet driver as described in chapter 4. Note that due to the time required, the pass-through method is not suitable for configuring a network nor for real time monitoring of your network devices. Allen-Bradley Replacements

78 5-8 Communicating with DeviceNet from Another Network When RSNetWorx for DeviceNet is finished browsing, the network displayed on your screen should look similar to the one shown below. You are now communicating with the DeviceNet network via the ControlNet network. See pages 4-6 to 4-17 of this manual for examples of how to use RSNetWorx for DeviceNet to adjust network parameters.

79 Communicating with DeviceNet from Another Network 5-9 Communicating with DeviceNet from an Ethernet Network More Before performing this example the Ethernet network must be configured and running. A 1785-ENET module must be installed on the PLC-5 processor and connected to the network. See the PLC-5 Ethernet Interface Module User Manual (publication ) for more information. Establishing Ethernet pass-through communications involves four main steps: 1. You use RSLinx to configure the Ethernet to PLC-5 driver. This procedure is described on pages 5-9 to You configure the 1785-ENET module s communications channel and download the configuration to the PLC-5 processor. This can be done using RSLogix 5 software when you create the example ladder program. The Ethernet channel configuration is described in Appendix A. 3. You use RSLinx to configure the DeviceNet pass-through driver to communicate with the 1771-SDN module via the Ethernet network. This procedure is described on pages 5-12 to You use the pass-through driver with RSNetWorx for DeviceNet software to adjust and tune your DeviceNet network. This procedure is described on pages 5-15 to Configuring the Ethernet to PLC-5 Communications Driver To communicate with your PLC-5 processor over an Ethernet network you must configure the Ethernet to PLC-5 driver. Perform the following steps to configure the driver using RSLinx software. 1. Start RSLinx. Allen-Bradley Replacements

80 5-10 Communicating with DeviceNet from Another Network 2. From the Communications menu, select Configure Drivers. 3. From the list of Available Driver Types, select the Ethernet to PLC-5/SLC-5/5820-EI driver and click on Add New. You will be prompted to choose a name for the new driver. 4. Enter an appropriate driver name (e.g., AB_ETH-1) and click on the OK button. The Configure driver for Ethernet to PLC-5/SLC-5/5820-EI window will open.

81 Communicating with DeviceNet from Another Network In the IP address or hostname field, enter the IP address of the PLC-5 processor ( in this example). IMPORTANT You must configure the PLC-5 s communications using BOOTP software or your PLC-5 programming software (e.g., RSLogix 5) before you will be able to communicate with the PLC-5 using this Ethernet address. See Appendix A for information on configuring the PLC-5 s communications using RSLogix Click on the Accept button. Then click on OK. The new driver will be added to the list of Configured Drivers in RSLinx. (Your list will contain the drivers you have configured.) Allen-Bradley Replacements

82 5-12 Communicating with DeviceNet from Another Network Configuring the DeviceNet Pass-Through Driver Before you can communicate with the 1771-SDN module via the Ethernet network, you must configure the DeviceNet pass-through driver (1771-SDNPT). RSLinx, version 2.10 or higher, is required. Connect your 1785-ENET module to your Ethernet network. Then perform the following steps. 1. Start RSLinx. 2. From the Communications menu, select Configure Drivers. 3. From the list of Available Driver Types select DeviceNet Drivers and click on Add/New.

83 Communicating with DeviceNet from Another Network 5-13 You will see the following list of drivers. 4. Select the Allen-Bradley 1771-SDNPT driver. The Allen-Bradley 1771-SDNPT Driver Configuration window will open. 5. Select a pass-through port to be configured from the pull-down list, e.g., Port Expand your Ethernet driver (AB_ETH-1) and highlight your PLC-5 processor. Allen-Bradley Replacements

84 5-14 Communicating with DeviceNet from Another Network 7. Select the 1771-SDN Backplane Address Configuration. We used the following configuration for the example application. Rack 0 Group 1 Slot 0 8. Select the DeviceNet channel (Channel 1 for the example application). 9. Click on OK. You will see the following warning: 10. Verify that the routing information is accurate and click on the Yes button. You will be prompted to enter a name for the driver. 11. Enter an appropriate driver name (e.g., 1771-SDNPT-2) and click on the OK button.

85 Communicating with DeviceNet from Another Network 5-15 The new driver will be added to the list of Configured Drivers in RSLinx. (Your list will contain the drivers you have configured.) 12. Close or Minimize RSLinx. Communicating with the DeviceNet Network Once you have the Ethernet pass-through driver configured, you can use RSNetWorx for DeviceNet to communicate with the DeviceNet network via the Ethernet network. Perform the following steps: 1. Start RSNetWorx. Allen-Bradley Replacements

86 5-16 Communicating with DeviceNet from Another Network 2. From the File menu, select New. If you have RSNetWorx for ControlNet installed on your computer you may see the following window. Otherwise, proceed to step Select DeviceNet Configuration and click on OK. 4. Click on the Online button on the toolbar. The Browse for network window will appear. You will see the drivers you have configured on your system. 5. Highlight the 1771-SDNPT-2, DeviceNet driver and click on OK.

87 Communicating with DeviceNet from Another Network 5-17 You will receive the following prompt: 6. Click on OK to upload the devices. RSNetWorx for DeviceNet will begin browsing for network devices. ATTENTION! Performing a pass-through browse via the Ethernet network will take longer than browsing using the 1770-KFD DeviceNet driver as described in chapter 4. Note that due to the time required, the pass-through method is not suitable for configuring a network nor for real time monitoring of your network devices. When RSNetWorx for DeviceNet is finished browsing, the network displayed on your screen should look similar to the one shown below. You are now communicating with the DeviceNet network via the Ethernet network. See pages 4-6 to 4-17 of this manual for examples of how to use RSNetWorx for DeviceNet to adjust network parameters. Allen-Bradley Replacements

88 5-18 Communicating with DeviceNet from Another Network Communicating with DeviceNet from a DH+ Network Before performing this example the DH+ network must be configured and running. In this example, the PLC-5 processor s DH+ channel A is configured as node 1. Use your own DH+ configuration when performing this example. Configuring the DeviceNet Pass-Through Driver Before you can communicate with the 1771-SDN module via a DH+ network, you must first configure the DeviceNet pass-through driver (1771-SDNPT) with a DH+ port. RSLinx, version 2.10 or higher, is required. Perform the following steps. 1. Start RSLinx. 2. From the Communications menu, select Configure Drivers. The Configure Drivers window will appear. 3. Select DeviceNet Drivers from the Available Driver Types pull-down list and click on Add/New.

89 Communicating with DeviceNet from Another Network 5-19 You will see the following list of drivers. 4. Select the Allen-Bradley 1771-SDNPT driver. The Driver Configuration window will appear. 5. Select a pass-through port to be configured from the pull-down list, e.g., Port Expand your DH+ driver (AB_KT-1 above) and highlight the PLC-5 processor. 7. Select the 1771-SDN Backplane Address Configuration. We used the following configuration for the example application. Rack 0 Group 1 Slot 0 8. Select the DeviceNet Channel (Channel 1 for the example application). Allen-Bradley Replacements

90 5-20 Communicating with DeviceNet from Another Network 9. Click on OK. You will see the following warning: 10. Verify that the routing information is accurate and click on the Yes button. You will be prompted to enter a name for the driver. 11. Enter an appropriate driver name (e.g., 1771-SDNPT-3) and click on the OK button. The new driver will be added to the Configured Drivers in RSLinx. (Your list will contain the drivers you have configured.) 12. Close or Minimize RSLinx.

91 Communicating with DeviceNet from Another Network 5-21 Communicating with the DeviceNet Network Once you have the DH+ pass-through driver configured, you can use RSNetWorx for DeviceNet to communicate with the DeviceNet network via the DH+ network. Perform the following steps: 1. Start RSNetWorx. 2. From the File menu, select New. If you have RSNetWorx for ControlNet installed on your computer you may see the following window. Otherwise, proceed to step Select DeviceNet Configuration and click on OK. Allen-Bradley 4. Click on the Replacements Online button on the toolbar.

92 5-22 Communicating with DeviceNet from Another Network The Browse for network window will appear. You will see the drivers you have configured on your system. 5. Highlight the 1771-SDNPT-3 driver and click on OK. You will receive the following prompt: 6. Click on OK to upload the devices. RSNetWorx for DeviceNet will begin browsing for network devices. ATTENTION! Performing a pass-through browse via the DH+ network will take longer than browsing using the 1770-KFD DeviceNet driver as described in chapter 4. Note that due to the time required, the pass-through method is not suitable for configuring a network nor for real time monitoring of your network devices.

93 Communicating with DeviceNet from Another Network 5-23 When RSNetWorx for DeviceNet is finished browsing, the network displayed on your screen should look similar to the one shown below. You are now online to the DeviceNet network via the Data Highway Plus network. See pages 4-6 to 4-17 of this manual for examples of how to use RSNetWorx for DeviceNet to adjust network parameters. What s Next? The next chapter describes how to create and run the example application program to test the DeviceNet Network. Allen-Bradley Replacements

94 5-24 Communicating with DeviceNet from Another Network

95 Chapter 6 Creating and Running the Example Application Program What This Chapter Contains This chapter describes the procedure to create, download, and run an example ladder logic program to test the DeviceNet network. When the program is put into Run mode, pressing the START button on the network s RediSTATION will cause the red indicator light to come on and stay on until the STOP button is pressed. Passing an object in front of the photoeye will increment a counter. This chapter provides examples of downloading and running the program over ControlNet, Ethernet, and Data Highway Plus networks. You cannot directly communicate with the PLC-5 processor over the DeviceNet network. The 1771 I/O chassis used for these examples was set up with the following hardware: Module Rack Group Slot IP Address PLC-5/1785-ENET SDN n/a The following table describes what this chapter contains and where to find specific information. For information about See page Installing the Software 6-2 Creating the Example Application Program 6-2 Downloading and Running the Program 6-6 Downloading and Running the Program via a ControlNet Network 6-6 Downloading and Running the Program via an Ethernet Network 6-9 Downloading and Running the Program via a DH+ Network 6-12 More For more information, see Getting Results With RSLogix 5, Rockwell Software publication 9399-RL53GR. Allen-Bradley Replacements 1

96 6-2 Creating and Running the Example Application Program Installing the Software Install the RSLogix 5 software. 1. Insert the CD in the CD-ROM drive. Note: The CD-ROM supports Windows Autorun. Once inserted into the CD-ROM drive, if you have Autorun configured, the installation will automatically start at the first setup screen. If Autorun is not configured for your CD-ROM drive, go to step From the Start menu, choose Run. You will see the Run pop-up window. 3. Type d:/setup (if it doesn t appear automatically), where d: is your CD-ROM driver letter. 4. Click on OK. You see the progress bar, followed by the welcome screen. Creating the Example Application Program Perform the following steps to create the example application program. 1. Start RSLogix From the File menu select New.

97 Creating and Running the Example Application Program 6-3 The Select Processor Type window will open. 3. Enter the following information and click on OK. In this field Select or Enter Processor Name DNET_PLC Platform ControlNet Processor (Select your processor type) Series (Select your processor s series) Revision (Enter revision letter) Driver (Select a Driver) (1) Processor Node (Enter the Processor Node) (1) (1) You can use the Who Active button to select your communications driver. This is described in the Downloading sections of this chapter. TIP Ignore any prompts or warnings you receive about specifying ControlNet project files. That is not necessary for this example. Allen-Bradley Replacements

98 6-4 Creating and Running the Example Application Program 4. Enter the following ladder program. Input data file mapped by RSNetWorx for DeviceNet Length of 62 specifies the first data block. See the Automapping example in chapter 4. RediSTATION Start bit RediSTATION Indicator Light bit RediSTATION Stop bit Output data file mapped by RSNetWorx for DeviceNet Length of 62 specifies the first data block. See the Automapping example in chapter 4. Photoeye input bit 5. Save the program using an appropriate name, e.g., DNET_PLC.

99 Creating and Running the Example Application Program 6-5 IMPORTANT The first word of the BTW downloaded from the PLC-5 to block 62 is reserved as the scanner module command register. You must set bit 0 of the command register to 1 to place the scanner s DeviceNet Channel 1 in run mode. You can do this by double-clicking on file N10 in the project window and manually setting N10:0, bit 0 to 1 as shown below. Note: Set bit 2 to place Channel 2 in run mode. More See the 1771-SDN DeviceNet Scanner Module Installation Instructions (publication ) for more information on using the scanner module command register. Allen-Bradley Replacements

100 6-6 Creating and Running the Example Application Program Downloading and Running the Program The remaining sections of this chapter provide examples of downloading and running the program via the following networks: ControlNet (page 6-6) Ethernet (page 6-9) Data Highway Plus (page 6-12) Downloading and Running the Program via a ControlNet Network Follow the procedure below to download and run the example program via a ControlNet network. 1. Click on the RSLogix 5 Comms menu and select System Communications. 2. Click on the Who Active button.

101 Creating and Running the Example Application Program 6-7 RSLinx will open. You will see a window similar to the one below, displaying your system s driver configuration. 3. Expand the tree under your ControlNet driver and highlight the PLC-5 processor as shown above. Click on OK. 4. Click on the Download button. You will be asked if you want to proceed with the Download. You will see a message similar to the one below. 5. Click on Yes to download the program. You may be prompted to keep the existing online ControlNet configuration. 6. Click on Yes. The program will be downloaded to the processor. Allen-Bradley Replacements

102 6-8 Creating and Running the Example Application Program Testing the Example Program 1. After the download is complete, go online and put the PLC-5 processor in Run mode. 2. Press and release the START button on the RediSTATION. The red light should turn on. On your screen, you should see rung 1 in your ladder program being energized as you press the button. 3. Pass your hand back and forth over the photoeye several times. On your screen you should see the counter incrementing. 4. Press and release the STOP button on the RediSTATION. The red light should turn off. On your screen, you should see rung 2 in your ladder program being energized as you press the button. This completes the ControlNet example.

103 Creating and Running the Example Application Program 6-9 Downloading and Running the Program via an Ethernet Network IMPORTANT The Ethernet configuration must be downloaded to the PLC-5 processor before performing this example. See Appendix A. Follow the procedure below to download and run the example program via an Ethernet network. 1. Click on the RSLogix 5 Comms menu and select System Communications. 2. Click on the Who Active button. Allen-Bradley Replacements

104 6-10 Creating and Running the Example Application Program RSLinx will open. You will see a window similar to the one below, displaying your system s driver configuration. 3. Expand the tree under your Ethernet driver and highlight the PLC-5 processor as shown above. Click on OK. 4. Click on the Download button. You will be asked if you want to proceed with the Download. You will see a message similar to the one below. 5. Click on Yes to download the program. You may be prompted to keep the existing online ControlNet configuration. 6. Click on Yes. The program will be downloaded to the processor.

105 Creating and Running the Example Application Program 6-11 Testing the Example Program 1. After the download is complete, go online and put the PLC-5 processor in Run mode. 2. Press and release the START button on the RediSTATION. The red light should turn on. On your screen, you should see rung 1 in your ladder program being energized as you press the button. 3. Pass your hand back and forth over the photoeye several times. On your screen you should see the counter incrementing. 4. Press and release the STOP button on the RediSTATION. The red light should turn off. On your screen, you should see rung 2 in your ladder program being energized as you press the button. This completes the Ethernet example. Allen-Bradley Replacements

106 6-12 Creating and Running the Example Application Program Downloading and Running the Program via a DH+ Network Follow the procedure below to download and run the example program via a DH+ network. 1. Click on the RSLogix 5 Comms menu and select System Communications. 2. Click on the Who Active button. RSLinx will open. You will see a window similar to the one below, displaying your system s driver configuration. 3. Expand the tree under your DH+ driver and highlight the PLC-5 processor as shown above. Click on OK.

107 Creating and Running the Example Application Program Click on the Download button. You will be asked if you want to proceed with the Download. You will see a message similar to the one below. 5. Click on Yes to download the program. You may be prompted to keep the existing online ControlNet configuration. 6. Click on Yes. The program will be downloaded to the processor. Allen-Bradley Replacements

108 6-14 Creating and Running the Example Application Program Testing the Example Program 1. After the download is complete, go online and put the PLC-5 processor in Run mode. 2. Press and release the START button on the RediSTATION. The red light should turn on. On your screen, you should see rung 1 in your ladder program being energized as you press the button. 3. Pass your hand back and forth over the photoeye several times. On your screen you should see the counter incrementing. 4. Press and release the STOP button on the RediSTATION. The red light should turn off. On your screen, you should see rung 2 in your ladder program being energized as you press the button. This completes the Data Highway Plus example. What s Next? This concludes the example applications. The following chapter describes how the diagnostic indicators on the 1771-SDN module can be used for troubleshooting.

109 Chapter 7 Troubleshooting What This Chapter Contains This chapter describes the diagnostics provided by the LED diagnostic indicators on the 1771-SDN module s front panel. For information about the See page Module Status Indicator 7-1 Network Status Indicator 7-2 Node/Error Code Indicator 7-2 Module Status Indicator Module Status Indicator Network Status Indicator The bicolor (green/red) Module Status LED indicates whether the 1771-SDN module has power and is functioning properly. If the indicator is Off Then Module Status Indicator There is no power applied to the module. Take this action Verify power connections and apply power. Green The module is operating normally. No action required. Flashing Green The module is not configured. Configure the module. Flashing Red There is an invalid configuration. Verify DIP switch settings. Check configuration setup. Red The module has an unrecoverable fault. Replace the module. Top Part of Module Allen-Bradley Replacements 1

110 7-2 Troubleshooting Network Status Indicator Each of the channels (1 and 2) on the 1771-SDN Scanner module has a bicolor (green/red) network status indicator that provides troubleshooting information about the channel s communication links. Network Status Indicator If the indicator is Then Which indicates Take this action Off The device has no power or the The channel is disabled for DeviceNet Power-up the module, provide network channel is disabled for communication due to a bus off condition, loss of network power, or it has been intentionally disabled. communication. power to the channel, and be sure the channel is enabled in both the module configuration table and the module command word. Green Normal operation. All slave devices in the scanlist table are communicating normally with the module. None. Flashing Green Flashing Red Red The two-digit numeric display for the channel indicates an error code that provides more information about the condition of the channel. The two-digit numeric display for the channel displays an error code that provides more information about the condition of the channel. The communications channel has failed. The two digit numeric display for the channel displays an error code that provides more information about the condition of the channel. The channel is enabled but no communication is occurring. At least one of the slave devices in the module s scanlist table has failed to communicate with the module. The network has faulted. The module may be defective. Configure the scanlist table for the channel to add devices. Examine the failed device and the scanlist table for accuracy. Reset the module. If failures continue, replace module. Node/Error Code Indicator Top of Module Node/Error Code Indicator Each channel also has a Node/Error Code indicator that displays numeric codes providing diagnostic information. The display flashes at approximately one second intervals, depending on network traffic. The following table summarizes the meanings of the numeric codes. Numeric Display Code Summary Numeric Description Take this action Code 0-63 Normal operation. The numeric code is None. the 1771-SDN s node address on the DeviceNet network. 70 Module failed Duplicate Node Address check. 71 Illegal data in scanlist table (node number alternately flashes). 72 Slave device stopped communicating (node number alternately flashes). Change the module node address to another available one. The node address you selected is already in use on that channel. Reconfigure the scanlist table and remove any illegal data. Inspect the field devices and verify connections.

111 Troubleshooting 7-3 Numeric Code Description Numeric Display Code Summary 73 Device s identity information does not match electronic key in scanlist table entry (node number alternately flashes). Verify that the correct device is at this node number. Make sure that the device at the flashing node address matches the desired electronic key (vendor, product code, product type). 74 Data overrun on port detected. Modify your configuration and check for invalid data. Check network communication traffic. 75 No scanlist is active in the module. Enter a scanlist. 76 No direct network traffic for module detected. 77 Data size expected by the device does not match scanlist entry (node number alternately flashes). 78 Slave device in scanlist table does not exist (node number alternately flashes). 79 Module has failed to transmit a message. None. The module hears other network communication. Reconfigure your module for the correct transmit and receive data size. Add the device to the network, or delete the scanlist entry for that device. Make sure that your module is connected to a valid network. Check for disconnected cables. Verify baud rate. 80 Module is in IDLE mode. Put PLC-5 in RUN mode. Enable RUN bit in module command register. 81 Module is in FAULT mode. Check ladder program for cause of fault bits. 82 Error detected in sequence of fragmented I/O messages from device (node number alternately flashes). 83 Slave device is returning error responses when module attempts to communicate with it (node number alternately flashes). 84 Module is initializing the DeviceNet channel. 85 Data size larger than 255 bytes (node number alternately flashes). 86 Device is producing zero length data (idle state) while channel is in Run Mode. 88 This is not an error. At power-up and reset, the module displays all 14 segments of the node address and status display LEDs. Take this action Check scanlist table entry for slave device to make sure that input and output data lengths are correct. Check slave device configuration. Check accuracy of scanlist table entry. Check slave device configuration. Slave device may be in another master s scanlist. Reboot slave device. None. This code clears itself once module attempts to initialize all slave devices on the channel. Configure the device for a smaller data size. Check device configuration and slave node status. 90 User has disabled communication port. Reconfigure your module. Check the disable bit in the Module Command Register. Allen-Bradley Replacements None.

112 7-4 Troubleshooting Numeric Code Description Numeric Display Code Summary 91 Bus-off condition detected on comm port. Module is detecting communication errors. 92 No network power detected on comm port. Take this action Check DeviceNet connections and physical media integrity. Check system for failed slave devices or other possible sources of network interference. Provide network power. Make sure that module drop cable is providing network power to module comm port. 95 Application FLASH update in progress. None. Do not disconnect the module while application FLASH is in progress. You will lose any existing data in the module s memory. 97 Module halted by user command. Check ladder program for cause of fault bits. 98 Unrecoverable firmware failure. Service or replace your module. 99 Unrecoverable hardware failure. Service or replace your module.

113 Appendix A 1785-ENET Module Channel Configuration Configuring the Communications Channel Before you can communicate with the PLC-5 processor over an Ethernet network, you must configure the 1785-ENET module s Ethernet communications channel and download the configuration to the PLC-5 processor. The following example describes how to do this using RSLogix 5 software. 1. Select Channel Configuration under the Controller folder in the Project window. The Edit Channel Properties window will open. Allen-Bradley Replacements 1

114 A ENET Module Channel Configuration 2. Select the Channel 3A tab. 3. Select Ethernet as the Channel Type. 4. Uncheck the BOOTP Enabled box to disable BOOTP. 5. Enter the IP Address you want to assign to the PLC-5 processor (e.g., ). 6. Download the configuration to the processor, using a communications driver that was previously configured, (e.g, ControlNet or DH+). See chapter 6 for examples of downloading to the PLC-5 using these drivers.

115 Appendix B Installing and Configuring the ControlNet Communications Driver The examples using ControlNet in this manual were performed with a 1784-KTCX15 communication interface card installed in the personal computer that was used as a programming terminal. This appendix describes how to install and configure the 1784-KTCX15 card. Installing the 1784-KTCX15 Communication Interface Card Perform the following steps to install the 1784-KTCX15 card in your personal computer. 1. Set the card s base memory address location on switches S1 and S2. More For detailed information on installing the 1784-KTCX15, refer to the ControlNet Communication Interface Card Installation Instructions, publication number Front of Switches D000:0000 Factory-set address (recommended setting) S2 up (1) down (0) S1 Front View down (0) up (1) Side View 2. Set the card s base I/O space address location on switch S3. Front of Switches Front View Side View 240h shown up (1) down (0) (adjust for your system) S3 up (1) Allen-Bradley down Replacements (0) 1

116 B-2 Installing and Configuring the ControlNet Communications Driver These settings depend on the devices installed on your computer. We used the following addresses: Base I/O Space Address 240 Base Memory Address D000:000 (factory default) When deciding which addresses to use, remember that each card in your computer must have a unique base memory address and a unique base I/O space memory address. If another card in the host computer is using one or both of the selected addresses, you must change the card s switch settings to an available address. TIP Consult with your IT/PC support group to find out if it is necessary to change any of your computer s memory address or IRQ settings. 3. Insert the card in a vacant 16- or 32-bit ISA/EISA expansion slot. Configuring the 1784-KTCX15 Communications Driver After installing the card in the computer, you must run RSLinx to configure the driver. 1. Start RSLinx. 2. Select Configure Drivers from the Communications menu. The following window will appear: 3. Select the Allen-Bradley 1784-KT/KTC(X) device from the pull-down list and click on Add/New.

117 Installing and Configuring the ControlNet Communications Driver B-3 4. When prompted for a name for the new driver, select the default name assigned by the system, i.e., AB_KTC-1. The Configure Device window will appear: 5. Enter the following configuration: Station Name ABKTC Net. Address 17 (1) Interrupt None I/O Base 240 (2) Mem. Address D000 (2 ) (1) (2) This is an unscheduled device. For maximum efficiency, set its address higher than the highest scheduled address on your network. Modify as necessary for your system. 6. Click on OK to save your settings. 7. Close RSLinx. Allen-Bradley Replacements

118 B-4 Installing and Configuring the ControlNet Communications Driver

119 Appendix C Installing and Configuring the DH+ Communications Driver The examples using Data Highway Plus (DH+) in this manual were performed with a 1784-KTX communication interface card installed in the personal computer that was used as the programming terminal. This appendix describes how to install and configure the 1784-KTX card. Installing the 1784-KTX Communication Interface Card Perform the following steps to install the 1784-KTX card in your personal computer. Refer to the following figure. SW3 SW4 KTX Card More For more information, see the KTX Communication Interface Card User Manual, publication number CH2 CH ABCDEF ABCDEF ABCDEF ABCDEF CH (shown in IRQ5 position) SW3 F ABCDE SW4 F ABCDE D 7 Channel 1 Address shown in D700: position 1. Set the interrupt jumpers on the communication card (IRQ5 in this example). 2. Set the switches on the card (D700 in this example). 3. Insert the communication interface card into a vacant 16-bit ISA or EISA expansion slot and tighten the screw to secure the card. Allen-Bradley Replacements 1

120 C-2 Installing and Configuring the DH+ Communications Driver Configuring the 1784-KTX Communications Driver After installing the card in the computer, you must run RSLinx to configure the communications driver. 1. Start the RSLinx software. 2. From the Communications menu select Configure Drivers. The Configure Drivers window will appear: 3. From the list of Available Drivers, select the 1784-KT/KTX(D)/PKTX(D) driver from the pull-down list and click on Add/New. 4. When prompted for a name for the new driver, select the default name assigned by the system, AB_KT-1. The device s configuration window will open:

SLC 500 DeviceNet Scanner Module

SLC 500 DeviceNet Scanner Module SLC 500 DeviceNet Scanner Module 1747-SDN User Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application and

More information

DeviceNet PCI Communication Interface Card 1784-PCIDS, -CPCIDS. User Manual. Allen-Bradley Parts

DeviceNet PCI Communication Interface Card 1784-PCIDS, -CPCIDS. User Manual. Allen-Bradley Parts DeviceNet PCI Communication Interface Card 1784-PCIDS, -CPCIDS User Manual Allen-Bradley Parts Important User Information Because of the variety of uses for the products described in this publication,

More information

ControlLogix Multi-Vendor Interface Module DH-485 API

ControlLogix Multi-Vendor Interface Module DH-485 API ControlLogix Multi-Vendor Interface Module DH-485 API 1756-MVI User Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible for

More information

Installation Instructions

Installation Instructions Installation Instructions 1771-SDN/B DeviceNet Scanner Module Installation Instructions 1 (Catalog Number 1771-SDN/B) Use this document as a guide to installing your 1771-SDN/B Scanner Module. Before you

More information

DeviceNet Network Configuration

DeviceNet Network Configuration User Manual DeviceNet Network Configuration 1756 ControlLogix, 1756 GuardLogix, 1769 CompactLogix, 1769 Compact GuardLogix, 1789 SoftLogix, Studio 5000 Logix Emulate Important User Information Solid-state

More information

Compact I/O 1769-SDN DeviceNet Scanner Module

Compact I/O 1769-SDN DeviceNet Scanner Module Compact I/O 1769-SDN DeviceNet Scanner Module 1769-SDN User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment.

More information

Allen Bradley DeviceNet Monitor User (9240 Mon16) Manual Allen-Bradley HMIs

Allen Bradley DeviceNet Monitor User (9240 Mon16) Manual Allen-Bradley HMIs Allen-Bradley HMIs Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all

More information

ControlNet Adapter Module

ControlNet Adapter Module ControlNet Adapter Module (Catalog Numbers 1747-ACN15, 1747-ACNR15) User Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible

More information

Throughout this manual we use notes to make you aware of safety considerations:

Throughout this manual we use notes to make you aware of safety considerations: Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have

More information

Allen-Bradley. User Manual. PLC-5 Backup Communication Module (1785-BCM, 1785-BEM) product icon

Allen-Bradley. User Manual. PLC-5 Backup Communication Module (1785-BCM, 1785-BEM) product icon Allen-Bradley PLC-5 Backup Communication Module User Manual (1785-BCM, 1785-BEM) product icon Important User Information Because of the variety of uses for this product and because of the differences between

More information

Attention helps you: identify a hazard avoid the hazard recognize the consequences

Attention helps you: identify a hazard avoid the hazard recognize the consequences Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have

More information

ControlLogix Multi-Vendor Interface Module DF1 API

ControlLogix Multi-Vendor Interface Module DF1 API ControlLogix Multi-Vendor Interface Module DF1 API 1756-MVI User Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible for the

More information

SPI Protocol Interface Module Cat. No SPI Concepts Manual

SPI Protocol Interface Module Cat. No SPI Concepts Manual Concepts Manual Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary

More information

Throughout this manual we use notes to make you aware of safety considerations:

Throughout this manual we use notes to make you aware of safety considerations: Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have

More information

DeviceNet Communications

DeviceNet Communications DeviceNet Communications For PanelView Plus and PanelPlus CE Terminals 2711P User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical

More information

(Catalog Number 1770-KFD and 1770-KFDG)

(Catalog Number 1770-KFD and 1770-KFDG) Installation Instructions (Catalog Number 1770-KFD and 1770-KFDG) The 1770-KFD module is a portable RS-232 communication interface that provides a host computer access to a DeviceNet network. This document

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication Remote I/O Scanner Catalog Number 1747-SN Installation Instructions 2 Remote I/O Scanner Important User Information Because of the variety of uses for the products described in this publication, those

More information

Spare Allen-Bradley Parts

Spare Allen-Bradley Parts ControlNet Scanner Module 1747-SCNR Reference Manual Spare Allen-Bradley Parts Important User Information Because of the variety of uses for the products described in this publication, those responsible

More information

Allen-Bradley. User Manual. ControlNet Adapter Module. (Cat. No ACN and -ACNR Series B)

Allen-Bradley. User Manual. ControlNet Adapter Module. (Cat. No ACN and -ACNR Series B) Allen-Bradley ControlNet Adapter Module (Cat. No. 1771-ACN and -ACNR Series B) User Manual Important User Information Because of the variety of uses for the products described in this publication, those

More information

Throughout this manual we use notes to make you aware of safety considerations:

Throughout this manual we use notes to make you aware of safety considerations: Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have

More information

DeviceNet Adapter. 20-COMM-D FRN 1.xxx. User Manual

DeviceNet Adapter. 20-COMM-D FRN 1.xxx. User Manual DeviceNet Adapter 20-COMM-D FRN 1.xxx User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

More information

PanelView Standard Operator Terminals

PanelView Standard Operator Terminals PanelView Standard Operator Terminals PV300 Micro, PV300, PV550, PV600, PV900, PV1000, PV1400 User Manual Important User Information Because of the variety of uses for the products described in this publication,

More information

DeviceNet Communications Module

DeviceNet Communications Module DeviceNet Communications Module Catalog Number 1203-GK5 or 1336-GM5 Firmware 1.xxx-3.xxx TM CONFORMANCE TESTED User Manual Important User Information Solid state equipment has operational characteristics

More information

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction... 3 Product Overview... 3 About DeviceNet... 4 Overview... 4 MPCR DeviceNet Features... 4 Cabling and Drop Line Lengths

More information

PCI 2 Axis Servo Card

PCI 2 Axis Servo Card Installation Instructions PCI 2 Axis Servo Card (Catalog Number 1784-PM02AE) This manual provides the instructions for installing the PCI 2 Axis Servo card (1784-PM02AE) in a PC computer using the NT operating

More information

DeviceNet Starter Kit

DeviceNet Starter Kit DeviceNet Starter Kit 1787-GEN2SKIT, -2, -3, -4, -5, -6, -7 User Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible for the

More information

Simple Package Measurement Connected Components Building Block. Quick Start

Simple Package Measurement Connected Components Building Block. Quick Start Simple Package Measurement Connected Components Building Block Quick Start Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment.

More information

1791 Analog Block I/O Input/Output Modules User Manual

1791 Analog Block I/O Input/Output Modules User Manual User Manual Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary

More information

CENTERLINE 2100 Motor Control Centers EtherNet/IP Network Adapter

CENTERLINE 2100 Motor Control Centers EtherNet/IP Network Adapter User Manual CENTERLINE 2100 Motor Control Centers EtherNet/IP Network Adapter Catalog Numbers 2100-ENET Series A FRN 1.XXX Important User Information Solid-state equipment has operational characteristics

More information

Allen-Bradley. Application Guide. SCADA System. (Publication AG-6.5.8)

Allen-Bradley. Application Guide. SCADA System. (Publication AG-6.5.8) Allen-Bradley SCADA System (Publication AG-6.5.8) Application Guide Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application

More information

TECHNICAL NOTE TNPC07

TECHNICAL NOTE TNPC07 TECHNICAL NOTE TNPC07 Title: Configuring a DLCN DeviceNet card with an AB 1747-SDN Scanner Card RLC Product(s): DLCN This Technical Note should be used with the Red Lion Controls Product Bulletin DLCN,

More information

Allen-Bradley Motors

Allen-Bradley Motors Installation Instructions Firmware Update Instructions for Ethernet, Enhanced and ControlNet PLC-5 Programmable Controllers Purpose Firmware Update Kit Contents Hardware and Software Requirements This

More information

EtherNet/IP Adapter. 20-COMM-E FRN 2.xxx. User Manual. AB Drives

EtherNet/IP Adapter. 20-COMM-E FRN 2.xxx. User Manual. AB Drives AB Drives EtherNet/IP Adapter 20-COMM-E FRN 2.xxx User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety

More information

You cannot install the module unless the connector is fully extended. ATTENTION: Allen-Bradley HMIs

You cannot install the module unless the connector is fully extended. ATTENTION: Allen-Bradley HMIs This module mounts on a 1794 terminal base unit. 1. Rotate keyswitch (1) on terminal base unit (2) clockwise to position as required for this type of module. 2. Make certain the flexbus connector (3) is

More information

PLC-5 Programmable Controllers Comparison

PLC-5 Programmable Controllers Comparison PLC-5 Programmable Controllers Comparison Category Controller Catalog Number User Memory Words, Max Total I/O, Max Number of Communication Ports (mode) Standard PLC-5/11 175-L11B 5 1 DH+ or Remote I/O

More information

L5351 DeviceNet Communications Interface

L5351 DeviceNet Communications Interface L5351 DeviceNet Communications Interface Technical Manual HG353798 Issue 2 Copyright SSD Drives, Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or

More information

TECHNICAL NOTE TNDA05

TECHNICAL NOTE TNDA05 TECHNICAL NOTE TNDA05 Title: Configuring a PAXCDC30 DeviceNet card with an AB 1747- SDN Scanner Card RLC Product(s): PAXCDC30 This Technical Note is intended to be used along with the Red Lion Controls

More information

Allen-Bradley. User Manual. PanelView e Transfer Utility. (Cat. No. 2711E ND7)

Allen-Bradley. User Manual. PanelView e Transfer Utility. (Cat. No. 2711E ND7) Allen-Bradley PanelView e Transfer Utility User Manual (Cat. No. 2711E ND7) Important User Information Because of the variety of uses for the products described in this publication, those responsible for

More information

ArmorPoint I/O DeviceNet Adapters

ArmorPoint I/O DeviceNet Adapters ArmorPoint I/O DeviceNet Adapters 1738-ADN12, 1738-ADN18, 1738-ADN18P, 1738-ADNX User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical

More information

ControlNet Adapter. 20-COMM-C FRN 1.xxx. User Manual

ControlNet Adapter. 20-COMM-C FRN 1.xxx. User Manual ControlNet Adapter 20-COMM-C FRN 1.xxx User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

More information

1747-SDN DeviceNet Scanner Module

1747-SDN DeviceNet Scanner Module Installation Instructions 1747-SDN DeviceNet Scanner Module Cat. No. 1747-SDN/B Contents Use this document as a guide to install the 1747-SDN/B scanner module. For this information See page Important User

More information

ControlLogix Multi-Vendor Interface Module 1756-MVI. Programming Reference Manual. AB Parts

ControlLogix Multi-Vendor Interface Module 1756-MVI. Programming Reference Manual. AB Parts ControlLogix Multi-Vendor Interface Module 1756-MVI Programming Reference Manual AB Parts Important User Information Because of the variety of uses for the products described in this publication, those

More information

D0 DEVNETS and Allen Bradley Set up. RSNetworx

D0 DEVNETS and Allen Bradley Set up. RSNetworx D0 DEVNETS and Allen Bradley Set up RSNetworx G 2 Setup D0 DEVNETS with Allen Bradley RSNetWorx For those who are using the D0 DEVNETS as a slave with an Allen Bradley PLC, the examples on the following

More information

ControlNet Modules in Logix5000 Control Systems

ControlNet Modules in Logix5000 Control Systems ControlNet Modules in Logix5000 Control Systems 1734-ACNR, 1756-CNB, 1756-CNBR, 1784-PCC, 1784-PCIC, 1784-PCICS, 1788-CNC, 1788-CNCR, 1788-CNF, 1788-CNFR, 1794-ACN15, 1794-ACNR15, 1797-ACNR15 User Manual

More information

PLC 5/250 Programmable Controller System Overview

PLC 5/250 Programmable Controller System Overview System Overview Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary

More information

ControlLogix Digital I/O Modules

ControlLogix Digital I/O Modules ControlLogix Digital I/O Modules Input Modules 1756-IA16, -IA16I, -IA8D, -IB16, -IB16D, -IB16I, -IB32, -IC16, -IH16I, -IM16I, -IN16, -IV16, -IV32 Output Modules 1756-OA16, -OA16I, -OA8, -OA8D, -OA8E, -OB16D,

More information

SLC 500 BASIC and BASIC-T Modules

SLC 500 BASIC and BASIC-T Modules SLC 500 BASIC and BASIC-T Modules (Catalog Numbers 1746-BAS and 1746-BAS-T) User Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible

More information

Teaching Color-Sensing Connected Components Building Block. Quick Start

Teaching Color-Sensing Connected Components Building Block. Quick Start Teaching Color-Sensing Connected Components Building Block Quick Start Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment.

More information

ControlNet Adapters. User Manual. 20-COMM-C (coax) 20-COMM-Q (fiber) FRN 1.xxx

ControlNet Adapters. User Manual. 20-COMM-C (coax) 20-COMM-Q (fiber) FRN 1.xxx ControlNet Adapters 20-COMM-C (coax) 20-COMM-Q (fiber) FRN 1.xxx User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment.

More information

DH-485/RS-232C Interface Module. Catalog Number 1747-KE. User Manual. AB Parts

DH-485/RS-232C Interface Module. Catalog Number 1747-KE. User Manual. AB Parts DH-485/RS-232C Interface Module Catalog Number 1747-KE User Manual AB Parts Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment.

More information

Configuration for General DIP Devices. Setting Up RSLinx

Configuration for General DIP Devices. Setting Up RSLinx Configuration for General DIP Devices Setting Up RSLinx Start Up RSLinx Program. Go to Communications Configure Drivers. Then, select an Available Driver Type (example, DeviceNet drivers). Once the appropriate

More information

FlexLogix System L33 and 1794-L34. User Manual. Allen-Bradley HMIs

FlexLogix System L33 and 1794-L34. User Manual. Allen-Bradley HMIs FlexLogix System 1794-L33 and 1794-L34 User Manual Allen-Bradley HMIs Important User Information Because of the variety of uses for the products described in this publication, those responsible for the

More information

Enhanced DeviceNet Communications Module

Enhanced DeviceNet Communications Module Enhanced DeviceNet Communications Module Catalog Numbers: 1203-GU6 and 1336-GM6 Firmware: 2.xxx User Manual Important User Information Because of the variety of uses for the products described in this

More information

Installation Instructions

Installation Instructions Installation Instructions (Catalog Number 1771-IR Series D) Use this document as a guide when installing the 1771-IR/D input module. The RTD input module is sensitive to electrostatic discharge. ATTENTION:

More information

PCI 2 Axis Servo Card

PCI 2 Axis Servo Card Installation Instructions PCI 2 Axis Servo Card (Catalog Number 1784-PM02AE) This manual provides the instructions for installing the PCI 2 Axis Servo card (1784-PM02AE) in a PC computer using the NT operating

More information

MPCR Series DeviceNet Technical Manual

MPCR Series DeviceNet Technical Manual MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction...3 Product Overview...3 About DeviceNet...4 Overview...4 MPCR DeviceNet Features...4 Cabling and Drop Line Lengths (as

More information

1747-SDN DeviceNet Scanner Module

1747-SDN DeviceNet Scanner Module Installation Instructions 1747-SDN DeviceNet Scanner Module Cat. No. 1747-SDN/B Contents Use this document as a guide to install the 1747-SDN/B scanner module. For this information See page Important User

More information

Installation Instructions

Installation Instructions Installation Instructions (Catalog Number 1771-OD) This document provides information on: Because of the variety of uses for the products described in this publication, those responsible for the application

More information

User Manual FRN 1.xx 2.xx

User Manual FRN 1.xx 2.xx Allen-Bradley Bulletin 160 DeviceNet Communication Module User Manual FRN 1.xx 2.xx Important User Information Because of the variety of uses for the products described in this publication, those responsible

More information

PLC-5 Programmable Controllers Comparison

PLC-5 Programmable Controllers Comparison PLC-5 Programmable Controllers Comparison Category Controller Catalog Number User Memory Words, Max Total I/O, Max Number of Communication Ports (mode) Standard PLC-5/11 175-L11B 5 1 DH+ or Remote I/O

More information

Color-Sensing Connected Components Building Block. Quick Start

Color-Sensing Connected Components Building Block. Quick Start Color-Sensing Connected Components Building Block Quick Start Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety

More information

Allen-Bradley. User Manual. DeviceView Configurator (2707-DNC)

Allen-Bradley. User Manual. DeviceView Configurator (2707-DNC) Allen-Bradley DeviceView Configurator (2707-DNC) User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety

More information

DeviceNet Adapter for use with DPI AC Drives

DeviceNet Adapter for use with DPI AC Drives DeviceNet Adapter for use with DPI AC Drives M/N RECOMM-DNET Instruction Manual D2-3478 The information in this manual is subject to change without notice. Throughout this manual, the following notes are

More information

ControlLogix SIL2 System Configuration

ControlLogix SIL2 System Configuration ControlLogix SIL2 System Configuration Using RSLogix 5000 Subroutines Application Technique (Catalog Numbers 1756 and 1492) Important User Information 8 / 2011 Solid state equipment has operational characteristics

More information

Installation Instructions

Installation Instructions Installation Instructions (Cat. No. 1771-OBN Series B) Use this document as a guide when installing the catalog number 1771-OBN series B output module. Because of the variety of uses for the products described

More information

PowerMonitor 5000 Unit Catalog Number Upgrade

PowerMonitor 5000 Unit Catalog Number Upgrade Installation Instructions PowerMonitor 5000 Unit Catalog Number Upgrade Catalog Numbers 1426-MxE-xxx Topic Page Upgrade the Device Catalog Number with the ControlFLASH Utility 3 Determine Communication

More information

ControlLogix Analog I/O Modules

ControlLogix Analog I/O Modules ControlLogix Analog I/O Modules 1756-IF16,- IF6CIS, -IF6I, -IF8, -IR6I, -IT6I, -IT6I2, -OF4, -OF6CI, -OF6VI, -OF8 User Manual Important User Information Because of the variety of uses for the products

More information

Integrating DeviceNet into ProcessLogix* 1756-DNB, 1757 Series. *ProcessLogix R510.0 and above. Application Technique. AB Drives

Integrating DeviceNet into ProcessLogix* 1756-DNB, 1757 Series. *ProcessLogix R510.0 and above. Application Technique. AB Drives Integrating DeviceNet into ProcessLogix* 1756-DNB, 1757 Series *ProcessLogix R510.0 and above. Application Technique AB Drives Important User Information Because of the variety of uses for the products

More information

PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer

PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer Installation Instructions PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer Catalog Number 6189V-2PCI15R Topic Page About This Publication 1 Important User Information 2 Safety

More information

Installation Instructions

Installation Instructions Installation Instructions This document provides information on: important pre-installation considerations power supply requirements initial handling procedures installing the module using the indicators

More information

BECKHOFF. Application Notes.

BECKHOFF. Application Notes. BECKHOFF Application Notes www.beckhoffautomation.com Configuring Beckhoff Products for an AB 1747- SDN DeviceNet Scanner with an SLC-500 PLC and RSNetWorx BK-AppNote-009 1.0 3 October 2007 For additional

More information

User Manual. PowerFlex ENETR Dual-port EtherNet/IP Option Module Firmware Revision Number 1.xxx

User Manual. PowerFlex ENETR Dual-port EtherNet/IP Option Module Firmware Revision Number 1.xxx User Manual PowerFlex 20-750-ENETR Dual-port EtherNet/IP Option Module Firmware Revision Number 1.xxx Important User Information Solid-state equipment has operational characteristics differing from those

More information

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout Installation Instructions Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout Catalog Numbers 2711-NR5T, 2711P-RAT12E2 Topic Page About This Publication 1 Important User Information 2 About

More information

Installation Instructions

Installation Instructions Installation Instructions (Cat. No. 71-A1B, -A2B, -A3B, -A3B1, -A4B Series B) Because of the variety of uses for the products described in this publication, those responsible for the application and use

More information

DeviceNet Safety Scanner for GuardPLC Controllers

DeviceNet Safety Scanner for GuardPLC Controllers DeviceNet Safety Scanner for GuardPLC Controllers Catalog Number 1753-DNSI User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical

More information

Logix5000 Control Systems: Connect POINT I/O Modules over a DeviceNet Network

Logix5000 Control Systems: Connect POINT I/O Modules over a DeviceNet Network Quick Start Logix5000 Control Systems: Connect POINT I/O Modules over a DeviceNet Network Catalog Numbers Logix5000 Controllers, 1734 POINT I/O Modules Important User Information Solid-state equipment

More information

BridgeWay. PROFIBUS to DeviceNet Gateway User Manual. Part No. AB7605. Publication PUB-AB

BridgeWay. PROFIBUS to DeviceNet Gateway User Manual. Part No. AB7605. Publication PUB-AB BridgeWay PROFIBUS to DeviceNet Gateway User Manual Part No. AB7605 Pyramid Solutions 1850 Research Drive, Suite 300 Troy, Michigan 48083 Phone 248-524-3890 Web www.pyramid-solutions.com Publication PUB-AB7605-005

More information

EtherNet/IP Communications Module

EtherNet/IP Communications Module EtherNet/IP Communications Module M/N RECOMM-ENET Firmware Version 2.xxx Firmware Version 3.xxx Instruction Manual D2-3510-1 The information in this manual is subject to change without notice. Throughout

More information

Kinetix 6000 Axis Module and Shunt Module

Kinetix 6000 Axis Module and Shunt Module Installation Instructions Kinetix 6000 and Shunt Module Catalog Numbers 2094-AMxx, 2094-BMxx 2094-AMxx-S, 2094-BMxx-S 2094-BSP2 Topic Page About This Publication 1 Important User Information 2 Before You

More information

ControlLogix Redundancy Update and Module Replacement Guidelines

ControlLogix Redundancy Update and Module Replacement Guidelines Reference Manual Original Instructions ControlLogix Redundancy Update and Module Replacement Guidelines Product Family ControlLogix 5570 Controllers Important User Information Read this document and the

More information

FLEX I/O Dual Port EtherNet/IP Adapter Modules

FLEX I/O Dual Port EtherNet/IP Adapter Modules User Manual FLEX I/O Dual Port EtherNet/IP Adapter Modules Catalog Numbers 1794-AENTR, 1794-AENTRXT Important User Information Solid-state equipment has operational characteristics differing from those

More information

PowerFlex 525 DeviceNet Adapter

PowerFlex 525 DeviceNet Adapter User Manual PowerFlex 525 DeviceNet Adapter Catalog Number: 25-COMM-D Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment.

More information

Allen-Bradley. User Manual. Remote I/O Adapter Module. (Cat. No ASB Series C and D)

Allen-Bradley. User Manual. Remote I/O Adapter Module. (Cat. No ASB Series C and D) Allen-Bradley Remote I/O Adapter Module (Cat. No. 1794-ASB Series C and D) User Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

Logix5000 Controllers Produced and Consumed Tags

Logix5000 Controllers Produced and Consumed Tags Logix5 Controllers Produced and Consumed Tags Catalog Numbers 1756 ControlLogix, 1756 GuardLogix, 1768 Compact GuardLogix, 1769 CompactLogix, 1789 SoftLogix, PowerFlex with DriveLogix Programming Manual

More information

ControlLogix Digital I/O Modules

ControlLogix Digital I/O Modules User Manual ControlLogix Digital I/O Modules Catalog Numbers 1756-IA8D, 1756-IA16, 1756-IA16I, 1756-IA32, 1756-IB16, 1756-IB16D, 1756-IB16I, 1756-IB16IF, 1756-IB32, 1756-IC16, 1756-IG16, 1756-IH16I, 1756-IM16I,

More information

SLC 500 Modular Hardware Style

SLC 500 Modular Hardware Style SLC 500 Modular Hardware Style Catalog Numbers 1747-L511, 1747-L514, 1747-L524, 1747-L531, 1747-L532, 1747-L533, 1747-L541, 1747-L542, 1747-L543, 1747-L551, 1747-L552, 1747-L553 User Manual Important User

More information

Block I/O Cat. No IOBA and -IOBB Series B User Manual

Block I/O Cat. No IOBA and -IOBB Series B User Manual User Manual Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary

More information

User Manual. PowerFlex DNET DeviceNet Option Module Firmware Revision Number 1.xxx

User Manual. PowerFlex DNET DeviceNet Option Module Firmware Revision Number 1.xxx User Manual PowerFlex 20-750-DNET DeviceNet Option Module Firmware Revision Number 1.xxx Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical

More information

How to Configure DeviceNet with Anybus Configuration Manager (ACM) for DeviceNet APPLICATION NOTE DRAFT

How to Configure DeviceNet with Anybus Configuration Manager (ACM) for DeviceNet APPLICATION NOTE DRAFT How to Configure DeviceNet with Anybus Configuration Manager (ACM) for DeviceNet APPLICATION NOTE ENGLISH Important User Information Liability Every care has been taken in the preparation of this document.

More information

Installation Instructions

Installation Instructions Installation Instructions Cat. No. 1771 P3, P4, P5 and P5E Use this document as a guide when installing the catalog number 1771-P3, -P4, -P5 or -P5E power supplies. Because of the variety of uses for the

More information

(Catalog Number 1747-SN) Product Data

(Catalog Number 1747-SN) Product Data (Catalog Number 1747-SN) Product Data At communication rates up to 230.4K baud, the Remote I/O Scanner provides connectivity of your SLC 500 processor to Allen-Bradley operator interface devices, drives,

More information

Using GuardShield Light Curtains (Safe 4, Micro 400, or 440L), with ArmorBlock Guard I/O and SmartGuard Controller

Using GuardShield Light Curtains (Safe 4, Micro 400, or 440L), with ArmorBlock Guard I/O and SmartGuard Controller Safety Application Example Using GuardShield Light Curtains (Safe 4, Micro 400, or 440L), with ArmorBlock Guard I/O and SmartGuard Controller Light Curtain with On-machine Components Safety Rating: Category

More information

DeviceNet To SCANport Communication Module with Digital Inputs

DeviceNet To SCANport Communication Module with Digital Inputs DeviceNet To SCANport Communication Module with Digital Inputs Catalog Number 2100-GK61 Firmware 2.xxx User Manual Important User Information Because of the variety of uses for the products described in

More information

Using TLS3-GD2 Guardlocking Interlock with ArmorBlock Guard I/O and SmartGuard Controller

Using TLS3-GD2 Guardlocking Interlock with ArmorBlock Guard I/O and SmartGuard Controller Safety Application Example Using TLS3-GD2 Guardlocking Interlock with ArmorBlock Guard I/O and SmartGuard Controller Guardlocking with On-machine Components Safety Rating: Category 3, according to EN954-1

More information

Installation Instructions

Installation Instructions Installation Instructions This document provides information on: important pre-installation considerations power supply requirements initial handling installing the module using the indicators for troubleshooting

More information

Backup Scanner Module

Backup Scanner Module Backup Scanner Module (Catalog Number 747-BSN) User Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application

More information

Preface Digital Electronics Corporation. All rights reserved. Digital Electronics Corporation December LT Type-D User Manual Supplement 1

Preface Digital Electronics Corporation. All rights reserved. Digital Electronics Corporation December LT Type-D User Manual Supplement 1 Preface Thank you for purchasing the Pro-face LogiTouch Type-D DeviceNet master unit. The LogiTouch Type-D (also referred to as the LT Type-D ) allows connection to the DeviceNet Fieldbus to access many

More information

Catalog Numbers 9308-RSFB64ENE, 9308-RSFB256ENE, 9308-RSFB1024ENE

Catalog Numbers 9308-RSFB64ENE, 9308-RSFB256ENE, 9308-RSFB1024ENE Release Notes RSFieldbus Software Catalog Numbers 9308-RSFB64ENE, 9308-RSFB256ENE, 9308-RSFB1024ENE Topic Page Important User Information 2 Before You Begin 3 Software Requirements 4 Install the Software

More information